diff options
Diffstat (limited to 'doc/rfc/rfc1304.txt')
-rw-r--r-- | doc/rfc/rfc1304.txt | 1403 |
1 files changed, 1403 insertions, 0 deletions
diff --git a/doc/rfc/rfc1304.txt b/doc/rfc/rfc1304.txt new file mode 100644 index 0000000..2a586ba --- /dev/null +++ b/doc/rfc/rfc1304.txt @@ -0,0 +1,1403 @@ + + + + + + +Network Working Group T. Cox +Request For Comments: 1304 K. Tesink + Editors + Bell Communications Research + February 1992 + + + Definitions of Managed Objects + for the SIP Interface Type + +Status of this Memo + + This RFC specifies an IAB standards track protocol for the Internet + community, and requests discussion and suggestions for improvements. + Please refer to the current edition of the "IAB Official Protocol + Standards" for the standardization state and status of this protocol. + Distribution of this memo is unlimited. + +Abstract + + This memo defines a portion of the Management Information Base (MIB) + for use with network management protocols in TCP/IP-based internets. + In particular, it defines objects for managing SIP (SMDS Interface + Protocol) objects. + +Table of Contents + + 1. The Network Management Framework ............................ 2 + 2. Objects ..................................................... 2 + 2.1 Format of Definitions ...................................... 3 + 3. Overview .................................................... 3 + 4. Object Definitions .......................................... 4 + 4.1 The SIP Level 3 group ...................................... 4 + 4.2 The SIP Level 2 group ...................................... 8 + 4.3 The SIP PLCP group ......................................... 11 + 4.3.1 The SIP DS1 PLCP group ................................... 12 + 4.3.2 The SIP DS3 PLCP group ................................... 14 + 4.4 The SMDS Applications group ................................ 16 + 4.5 The SMDS Carrier Selection group ........................... 18 + 4.6 The SIP Error Log group .................................... 18 + 5. Acknowledgments ............................................. 23 + 6. References .................................................. 23 + 7. Security Considerations...................................... 25 + 8. Authors' Addresses........................................... 25 + + + + + + + +SNMP Working Group [Page 1] + +RFC 1304 SIP Objects February 1992 + + +1. The Network Management Framework + + The Internet-standard Network Management Framework consists of three + components. They are: + + RFC 1155 [3] which defines the SMI, the mechanisms used for + describing and naming objects for the purpose of management. RFC + 1212 [9] defines a more concise description mechanism, which is + wholly consistent with the SMI. + + RFC 1156 [4] which defines MIB-I, the core set of managed objects + for the Internet suite of protocols. RFC 1213 [6], defines MIB- + II, an evolution of MIB-I based on implementation experience and + new operational requirements. + + RFC 1157 [5] which defines the SNMP, the protocol used for network + access to managed objects. + + The Framework permits new objects to be defined for the purpose of + experimentation and evaluation. + +2. Objects + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. Objects in the MIB are + defined using the subset of Abstract Syntax Notation One (ASN.1) + International Standard 8824 [7] defined in the SMI. In particular, + each object has a name, a syntax, and an encoding. The name is an + object identifier, an administratively assigned name, which specifies + an object type. The object type together with an object instance + serves to uniquely identify a specific instantiation of the object. + For human convenience, we often use a textual string, termed the + OBJECT DESCRIPTOR, to also refer to the object type. + + The syntax of an object type defines the abstract data structure + corresponding to that object type. The ASN.1 language is used for + this purpose. However, the SMI RFC 1155 [3] purposely restricts the + ASN.1 constructs which may be used. These restrictions are + explicitly made for simplicity. + + The encoding of an object type is simply how that object type is + represented using the object type's syntax. Implicitly tied to the + notion of an object type's syntax and encoding is how the object type + is represented when being transmitted on the network. The SMI + specifies the use of the basic encoding rules of ASN.1 International + Standard 8825 [8], subject to the additional requirements imposed by + the SNMP. + + + + +SNMP Working Group [Page 2] + +RFC 1304 SIP Objects February 1992 + + +2.1. Format of Definitions + + Section 4 contains contains the specification of all object types + contained in this MIB module. The object types are defined using the + conventions defined in the SMI, as amended by the extensions + specified in RFC 1212 [9]. + +3. Overview + + These objects are used when the particular media being used to + realize an interface is a SIP interface. At present, this applies to + these values of the ifType variable in the Internet-standard MIB: + + sip (31) + + For these interfaces, the value of the ifSpecific variable in the + MIB-II [6] has the OBJECT IDENTIFIER value: + + sip OBJECT IDENTIFIER ::= { transmission 31 } + + The definitions contained herein are based on the SIP specifications + in Bellcore TR-TSV-000772 and TR-TSV-000773 [11,12]. + + The SIP (SMDS Interface Protocol) protocol stack is defined as + follows in TR-TSV-000772 [11]: + + ___________________ + | | + | SIP Level 3 [11] | + |___________________| + | | + | SIP Level 2 [11] | + |___________________| + | | + | PLCP [12] | + |___________________| + | | + | DS1 or DS3 [12] | + |___________________| + + The PLCP (Physical Layer Convergence Procedure) adapts the + capabilities of the transmission system (DS1 or DS3 formats) to the + service expected by SIP Level 2. Managed objects for DS1 and DS3 + Interface Types are defined in RFC 1232 [13] and RFC 1233 [14] + respectively (and amended in RFC 1239 [17]), and can be utilized for + management of SIP interfaces. This document defines managed objects + for the remaining protocol levels of the SIP Interface Type. This + document does not specify objects for the management of subscription + + + +SNMP Working Group [Page 3] + +RFC 1304 SIP Objects February 1992 + + + or configuration of Subscriber-Network Interfaces (SNIs). Those + objects are defined in Definitions of Managed Objects for SMDS + Subscription [18]. Bellcore requirements on these objects are + specified in TA-TSV-001062 [16]. + +4. Object Definitions + + RFC1304-MIB DEFINITIONS ::= BEGIN + + IMPORTS + Counter, TimeTicks, IpAddress + FROM RFC1155-SMI + transmission + FROM RFC1213-MIB + OBJECT-TYPE + FROM RFC-1212; + + -- This MIB module uses the extended OBJECT-TYPE macro + -- as defined in RFC-1212. + + -- This is the MIB module for the SIP objects. + + + sip OBJECT IDENTIFIER ::= { transmission 31 } + + -- All representations of SMDS addresses in this MIB + -- module use, as a textual convention (i.e., this + -- convention does not affect their encoding), the + -- data type: + + SMDSAddress ::= OCTET STRING (SIZE (8)) + -- the 60-bit SMDS address, preceded by 4 bits with the + -- following values: + -- "1100" when representing an individual address + -- "1110" when representing a group address + + + -- The SIP Level 3 group + -- Implementation of the SIP Level 3 group is mandatory + -- for all systems implementing SIP Level 3. + + sipL3Table OBJECT-TYPE + SYNTAX SEQUENCE OF SipL3Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table contains SIP L3 parameters and + state variables, one entry per SIP port." + + + +SNMP Working Group [Page 4] + +RFC 1304 SIP Objects February 1992 + + + ::= { sip 1 } + + sipL3Entry OBJECT-TYPE + SYNTAX SipL3Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This list contains SIP L3 parameters and + state variables." + INDEX { sipL3Index } + ::= { sipL3Table 1 } + + SipL3Entry ::= SEQUENCE { + sipL3Index + INTEGER, + sipL3ReceivedIndividualDAs + Counter, + sipL3ReceivedGAs + Counter, + sipL3UnrecognizedIndividualDAs + Counter, + sipL3UnrecognizedGAs + Counter, + sipL3SentIndividualDAs + Counter, + sipL3SentGAs + Counter, + sipL3Errors + Counter, + sipL3InvalidSMDSAddressTypes + Counter, + sipL3VersionSupport + INTEGER + } + + sipL3Index OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP + port interface for which this entry contains + management information. The value of this + object for a particular interface has the same + value as the ifIndex object, defined in RFC + 1156 and RFC 1213, for the same interface." + ::= { sipL3Entry 1 } + + + + +SNMP Working Group [Page 5] + +RFC 1304 SIP Objects February 1992 + + + sipL3ReceivedIndividualDAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of individually addressed SIP + Level 3 PDUs received from the remote system + across the SNI. The total includes only + unerrored L3PDUs." + ::= { sipL3Entry 2 } + + sipL3ReceivedGAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of group addressed SIP Level 3 + PDUs received from the remote system across the + SNI. The total includes only unerrored L3PDUs." + ::= { sipL3Entry 3 } + + sipL3UnrecognizedIndividualDAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + remote system with invalid or unknown individual + destination addresses (Destination Address + Screening violations are not included). See SMDS + Subscription MIB module." + ::= { sipL3Entry 4 } + + sipL3UnrecognizedGAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + remote system with invalid or unknown group + addresses. (Destination Address Screening + violations are not included). See SMDS + Subscription MIB module." + ::= { sipL3Entry 5 } + + sipL3SentIndividualDAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + + + +SNMP Working Group [Page 6] + +RFC 1304 SIP Objects February 1992 + + + STATUS mandatory + DESCRIPTION + "The number of individually addressed SIP Level 3 + PDUs that have been sent by this system across the + SNI." + ::= { sipL3Entry 6 } + + sipL3SentGAs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of group addressed SIP L3PDUs that + have been sent by this system across the SNI." + ::= { sipL3Entry 7 } + + -- The total number of SIP L3PDU errors can be calculated as + -- (Syntactic errors + Semantic Service errors ) + -- Syntactic errors include: + -- sipL3Errors + -- Latest occurrences of syntactic error types are logged in + -- sipL3PDUErrorTable. + -- Semantic Service errors include: + -- sipL3UnrecognizedIndividualDAs + -- sipL3UnrecognizedGAs + -- sipL3InvalidSMDSAddressTypes + -- Note that public networks supporting SMDS may discard + -- SIP L3PDUs due to subscription violations. Related + -- managed objects are defined in Definitions of Managed + -- Objects for SMDS Subscription. + + + sipL3Errors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of SIP Level 3 PDUs received + from the remote system that were discovered to + have errors (including protocol processing and bit + errors but excluding addressing-related errors) + and were discarded. Includes both group addressed + L3PDUs and L3PDUs containing an individual + destination address." + ::= { sipL3Entry 8 } + + + + + + +SNMP Working Group [Page 7] + +RFC 1304 SIP Objects February 1992 + + + sipL3InvalidSMDSAddressTypes OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + remote system that had the Source or Destination + Address_Type subfields, (the four most significant + bits of the 64 bit address field), not equal to + the value 1100 or 1110. Also, an error is + considered to have occurred if the Address_Type + field for a Source Address, the four most + significant bits of the 64 bits, is equal to 1110 + (a group address)." + ::= { sipL3Entry 9 } + + sipL3VersionSupport OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A value which indicates the version(s) of SIP + that this interface supports. The value is a sum. + This sum initially takes the value zero. For each + version, V, that this interface supports, 2 raised + to (V - 1) is added to the sum. For example, a + port supporting versions 1 and 2 would have a + value of (2^(1-1)+2^(2-1))=3. The + sipL3VersionSupport is effectively a bit mask with + Version 1 equal to the least significant bit + (LSB)." + ::= { sipL3Entry 10 } + + + -- The SIP Level 2 group + -- Implementation of the SIP Level 2 group is mandatory + -- for all systems implementing SIP Level 2. + + + sipL2Table OBJECT-TYPE + SYNTAX SEQUENCE OF SipL2Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table contains SIP L2PDU parameters and + state variables, one entry per SIP port." + ::= { sip 2 } + + + + +SNMP Working Group [Page 8] + +RFC 1304 SIP Objects February 1992 + + + sipL2Entry OBJECT-TYPE + SYNTAX SipL2Entry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This list contains SIP L2 parameters and state + variables." + INDEX { sipL2Index } + ::= { sipL2Table 1 } + + SipL2Entry ::= SEQUENCE { + sipL2Index + INTEGER, + sipL2ReceivedCounts + Counter, + sipL2SentCounts + Counter, + sipL2HcsOrCRCErrors + Counter, + sipL2PayloadLengthErrors + Counter, + sipL2SequenceNumberErrors + Counter, + sipL2MidCurrentlyActiveErrors + Counter, + sipL2BomOrSSMsMIDErrors + Counter, + sipL2EomsMIDErrors + Counter + } + + sipL2Index OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP port + interface for which this entry contains management + information. The value of this object for a + particular interface has the same value as the + ifIndex object, defined in RFC 1156 and RFC 1213, + for the same interface." + ::= { sipL2Entry 1 } + + sipL2ReceivedCounts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + + + +SNMP Working Group [Page 9] + +RFC 1304 SIP Objects February 1992 + + + DESCRIPTION + "The number of SIP Level 2 PDUs received from the + remote system across the SNI. The total includes + only unerrored L2PDUs." + ::= { sipL2Entry 2 } + + sipL2SentCounts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of SIP Level 2 PDUs that have been + sent by this system across the SNI." + ::= { sipL2Entry 3 } + + -- The total number of SIP L2PDU errors can be calculated as + -- the sum of: + -- sipL2HcsOrCRCErrors + -- sipL2PayloadLengthErrors + -- sipL2SequenceNumberErrors + -- sipL2MidCurrentlyActiveErrors + -- sipL2BomOrSSMsMIDErrors + -- sipL2EomsMIDErrors + + sipL2HcsOrCRCErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that were + discovered to have either a Header Check Sequence + error or a Payload CRC violation." + ::= { sipL2Entry 4 } + + sipL2PayloadLengthErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that had + Payload Length errors that fall in the following + specifications: + - SSM L2_PDU payload length field value less + - than 28 octets or greater than 44 octets, + + - BOM or COM L2_PDU payload length field not + - equal to 44 octets, + + + + +SNMP Working Group [Page 10] + +RFC 1304 SIP Objects February 1992 + + + - EOM L2_PDU payload length field value less + - than 4 octets or greater than 44 octets." + ::= { sipL2Entry 5 } + + sipL2SequenceNumberErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that had + a sequence number within the L2PDU not equal to + the expected sequence number of the SMDS SS + receive process." + ::= { sipL2Entry 6 } + + sipL2MidCurrentlyActiveErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that are + BOMs for which an active receive process is + already started." + ::= { sipL2Entry 7 } + + sipL2BomOrSSMsMIDErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that are + SSMs with a MID not equal to zero or are BOMs with + MIDs equal to zero." + ::= { sipL2Entry 8 } + + sipL2EomsMIDErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of received SIP Level 2 PDUs that are + EOMs for which there is no active receive process + for the MID (i.e., the receipt of an EOM which + does not correspond to a BOM) OR the EOM has a MID + equal to zero." + ::= { sipL2Entry 9 } + + + + + +SNMP Working Group [Page 11] + +RFC 1304 SIP Objects February 1992 + + + -- The SIP PLCP group + -- Implementation of one of these groups is mandatory + -- if the PLCP is implemented. + + sipPLCP OBJECT IDENTIFIER ::= { sip 3 } + + + -- The SIP DS1 PLCP group + -- Implementation of this group is mandatory + -- if the DS1 PLCP is implemented. + + sipDS1PLCPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipDS1PLCPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table contains SIP DS1 PLCP parameters and + state variables, one entry per SIP port." + ::= { sipPLCP 1 } + + sipDS1PLCPEntry OBJECT-TYPE + SYNTAX SipDS1PLCPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This list contains SIP DS1 PLCP parameters and + state variables." + INDEX { sipDS1PLCPIndex } + ::= { sipDS1PLCPTable 1 } + + SipDS1PLCPEntry ::= SEQUENCE { + sipDS1PLCPIndex + INTEGER, + sipDS1PLCPSEFSs + Counter, + sipDS1PLCPAlarmState + INTEGER, + sipDS1PLCPUASs + Counter + } + + + sipDS1PLCPIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP port + + + +SNMP Working Group [Page 12] + +RFC 1304 SIP Objects February 1992 + + + interface for which this entry contains management + information. The value of this object for a + particular interface has the same value as the + ifIndex object, defined in RFC 1156 and RFC 1213, + for the same interface." + ::= { sipDS1PLCPEntry 1 } + + + sipDS1PLCPSEFSs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A DS1 Severely Errored Framing Second (SEFS) is a + count of one-second intervals containing one or + more SEF events. A Severely Errored Framing (SEF) + event is declared when an error in the A1 octet + and an error in the A2 octet of a framing octet + pair (i.e., errors in both framing octets), or two + consecutive invalid and/or nonsequential Path + Overhead Identifier octets are detected." + ::= { sipDS1PLCPEntry 2 } + + sipDS1PLCPAlarmState OBJECT-TYPE + SYNTAX INTEGER { + noAlarm (1), + receivedFarEndAlarm (2), + incomingLOF (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable indicates if there is an alarm + present for the DS1 PLCP. The value + receivedFarEndAlarm means that the DS1 PLCP has + received an incoming Yellow Signal, the value + incomingLOF means that the DS1 PLCP has declared a + loss of frame (LOF) failure condition, and the + value noAlarm means that there are no alarms + present. See TR-TSV-000773 for a description of + alarm states." + ::= { sipDS1PLCPEntry 3 } + + + sipDS1PLCPUASs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + + + +SNMP Working Group [Page 13] + +RFC 1304 SIP Objects February 1992 + + + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, as defined by TR-TSV-000773, + encountered by the PLCP." + ::= { sipDS1PLCPEntry 4 } + + + -- The SIP DS3 PLCP group + -- Implementation of this group is mandatory + -- if the DS3 PLCP is implemented. + + sipDS3PLCPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipDS3PLCPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This table contains SIP DS3 PLCP parameters and + state variables, one entry per SIP port." + ::= { sipPLCP 2 } + + sipDS3PLCPEntry OBJECT-TYPE + SYNTAX SipDS3PLCPEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "This list contains SIP DS3 PLCP parameters and + state variables." + INDEX { sipDS3PLCPIndex } + ::= { sipDS3PLCPTable 1 } + + SipDS3PLCPEntry ::= SEQUENCE { + sipDS3PLCPIndex + INTEGER, + sipDS3PLCPSEFSs + Counter, + sipDS3PLCPAlarmState + INTEGER, + sipDS3PLCPUASs + Counter + } + + + sipDS3PLCPIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP port + + + +SNMP Working Group [Page 14] + +RFC 1304 SIP Objects February 1992 + + + interface for which this entry contains management + information. The value of this object for a + particular interface has the same value as the + ifIndex object, defined in RFC 1156 and RFC 1213, + for the same interface." + ::= { sipDS3PLCPEntry 1 } + + sipDS3PLCPSEFSs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A DS3 Severely Errored Framing Second (SEFS) is a + count of one-second intervals containing one or + more SEF events. A Severely Errored Framing (SEF) + event is declared when an error in the A1 octet + and an error in the A2 octet of a framing octet + pair (i.e., errors in both framing octets), or two + consecutive invalid and/or nonsequential Path + Overhead Identifier octets are detected." + ::= { sipDS3PLCPEntry 2 } + + sipDS3PLCPAlarmState OBJECT-TYPE + SYNTAX INTEGER { + noAlarm (1), + receivedFarEndAlarm (2), + incomingLOF (3) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable indicates if there is an alarm + present for the DS3 PLCP. The value + receivedFarEndAlarm means that the DS3 PLCP has + received an incoming Yellow Signal, the value + incomingLOF means that the DS3 PLCP has declared a + loss of frame (LOF) failure condition, and the + value noAlarm means that there are no alarms + present. See TR-TSV-000773 for a description of + alarm states." + ::= { sipDS3PLCPEntry 3 } + + + sipDS3PLCPUASs OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + + + +SNMP Working Group [Page 15] + +RFC 1304 SIP Objects February 1992 + + + "The counter associated with the number of + Unavailable Seconds, as defined by TR-TSV-000773, + encountered by the PLCP." + ::= { sipDS3PLCPEntry 4 } + + + -- The SMDS Applications group + -- Applications that have been identified for this group are: + -- * IP-over-SMDS (details are specified in RFC 1209) + -- Implementation of this group is mandatory for systems + -- that implement IP-over-SMDS Interface Protocol. + + smdsApplications OBJECT IDENTIFIER ::= { sip 4 } + + ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 } + + -- Although the objects in this group are read-only, at the + -- agent's discretion they may be made read-write so that the + -- management station, when appropriately authorized, may + -- change the addressing information related to the + -- configuration of a logical IP subnetwork implemented on + -- top of SMDS. + + -- This table is necessary to support RFC1209 (IP-over-SMDS) + -- and gives information on the Group Addresses and ARP + -- Addresses used in the Logical IP subnetwork. + -- One SMDS address may be associated with multiple IP + -- addresses. One SNI may be associated with multiple LISs. + + ipOverSMDSTable OBJECT-TYPE + SYNTAX SEQUENCE OF IpOverSMDSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The table of addressing information relevant to + this entity's IP addresses." + ::= { ipOverSMDS 1 } + + ipOverSMDSEntry OBJECT-TYPE + SYNTAX IpOverSMDSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The addressing information for one of this + entity's IP addresses." + INDEX { ipOverSMDSIndex, ipOverSMDSAddress } + ::= { ipOverSMDSTable 1 } + + + + +SNMP Working Group [Page 16] + +RFC 1304 SIP Objects February 1992 + + + IpOverSMDSEntry ::= + SEQUENCE { + ipOverSMDSIndex + INTEGER, + ipOverSMDSAddress + IpAddress, + ipOverSMDSHA + SMDSAddress, + ipOverSMDSLISGA + SMDSAddress, + ipOverSMDSARPReq + SMDSAddress + } + + ipOverSMDSIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP port + interface for which this entry contains management + information. The value of this object for a + particular interface has the same value as the + ifIndex object, defined in RFC 1156 and RFC 1213, + for the same interface." + ::= { ipOverSMDSEntry 1 } + + ipOverSMDSAddress OBJECT-TYPE + SYNTAX IpAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The IP address to which this entry's addressing + information pertains." + ::= { ipOverSMDSEntry 2 } + + ipOverSMDSHA OBJECT-TYPE + SYNTAX SMDSAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SMDS Individual address of the IP station." + ::= { ipOverSMDSEntry 3 } + + ipOverSMDSLISGA OBJECT-TYPE + SYNTAX SMDSAddress + ACCESS read-only + STATUS mandatory + + + +SNMP Working Group [Page 17] + +RFC 1304 SIP Objects February 1992 + + + DESCRIPTION + "The SMDS Group Address that has been configured + to identify the SMDS Subscriber-Network Interfaces + (SNIs) of all members of the Logical IP Subnetwork + (LIS) connected to the network supporting SMDS." + ::= { ipOverSMDSEntry 4 } + + ipOverSMDSARPReq OBJECT-TYPE + SYNTAX SMDSAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The SMDS address (individual or group) to which + ARP Requests are to be sent." + ::= { ipOverSMDSEntry 5 } + + + -- The SMDS Carrier Selection group + -- This group is used as a place holder + -- for carrier selection objects. + + smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5} + + + -- The SIP Error Log + -- Implementation of this group is mandatory + -- for all systems that implement SIP Level 3. + + sipErrorLog OBJECT IDENTIFIER ::= { sip 6 } + + sipL3PDUErrorTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipL3PDUErrorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A table that contains the latest occurrence of + the following syntactical SIP L3PDU errors: + + - Destination Address Field Format Error, + + The following pertains to the 60 least significant + bits of the 64 bit address field. The 60 bits + contained in the address subfield can be used to + represent addresses up to 15 decimal digits. Each + decimal digit shall be encoded into four bits + using Binary Coded Decimal (BCD), with the most + significant digit occurring left-most. If not all + 15 digits are required, then the remainder of this + + + +SNMP Working Group [Page 18] + +RFC 1304 SIP Objects February 1992 + + + field shall be padded on the right with bits set + to one. An error is considered to have occurred: + a). if the first four bits of the address + subfield are not BCD, OR b). if the first four + bits of the address subfield are populated with + the country code value 0001, AND the 40 bits which + follow are not Binary Coded Decimal (BCD) encoded + values of the 10 digit addresses, OR the remaining + 16 least significant bits are not populated with + 1's, OR c). if the address subfield is not + correct according to another numbering plan which + is dependent upon the carrier assigning the + numbers and offering SMDS. + + - Source Address Field Format Error, + + The description of this parameter is the same as + the description of the Destination Address Field + Format Error. + + - Invalid BAsize Field Value, + + An error is considered to have occurred when the + BAsize field of an SIP L3PDU contains a value less + that 32, greater than 9220 octets without the + CRC32 field present, greater than 9224 octets with + the CRC32 field present, or not equal to a + multiple of 4 octets, + + - Invalid Header Extension Length Field Value, + + An error is considered to have occurred when the + Header Extension Length field value is not equal + 3. + + - Invalid Header Extension - Element Length, + + An error is considered to have occurred when the + Header Extension - Element Length is greater than + 12. + + - Invalid Header Extension - Version Element + Position, Length, or Value, + + An error is considered to have occurred when a + Version element with Length=3, Type=0, and Value=1 + does not appear first within the Header Extension, + or an element Type=0 appears somewhere other than + + + +SNMP Working Group [Page 19] + +RFC 1304 SIP Objects February 1992 + + + within the first three octets in the Header + Extension. + + - Invalid Header Extension - Carrier Selection + Element Position, Length, Value or Format, + + An error is considered to have occurred when a + Carrier Selection element does not appear second + within the Header Extension, if the Element Type + does not equal 1, the Element Length does not + equal 4, 6, or 8, the Element Value field is not + four BCD encoded decimal digits used in specifying + the Carrier Identification Code (CIC), or the + identified CIC code is invalid. + + - Header Extension PAD Error + + An error is considered to have occurred when the + Header Extension PAD is 9 octets in length, or if + the Header Extension PAD is greater than zero + octets in length and the Header Extension PAD does + not follow all Header Extension elements or does + not begin with at least one octet of all zeros. + + - BEtag Mismatch Error, + + An error is considered to have occurred when the + Beginning-End Tags in the SIP L3PDU header and + trailer are not equal. + + - BAsize Field not equal to Length Field Error, + + An error is considered to have occurred when the + value of the BAsize Field does not equal the value + of the Length Field. + + - Incorrect Length Error, and + + An error is considered to have occurred when the + the Length field value is not equal to the portion + of the SIP L3PDU which extends from the + Destination Address field up to and including the + CRC32 field (if present) or up to and including + the PAD field (if the CRC32 field is not present). + As an optional check, an error is considered to + have occurred when the length of a partially + received SIP L3PDU exceeds the BAsize value. + + + + +SNMP Working Group [Page 20] + +RFC 1304 SIP Objects February 1992 + + + - MRI Timeout Error. + + An error is considered to have occurred when the + elapsed time between receipt of BOM and + corresponding EOM exceeds the value of the MRI + (Message Receive Interval) for a particular + transport signal format. + + An entry is indexed by interface number and error + type, and contains Source Address, Destination + Address and a timestamp. All these errors are + counted in the sipL3Errors counter. When + sipL3PDUErrorTimeStamp is equal to zero, the + SipL3PDUErrorEntry does not contain any valid + information." + ::= { sipErrorLog 1 } + + sipL3PDUErrorEntry OBJECT-TYPE + SYNTAX SipL3PDUErrorEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the service disagreement table." + INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType } + ::= { sipL3PDUErrorTable 1 } + + SipL3PDUErrorEntry ::= SEQUENCE { + sipL3PDUErrorIndex + INTEGER, + sipL3PDUErrorType + INTEGER, + sipL3PDUErrorSA + SMDSAddress, + sipL3PDUErrorDA + SMDSAddress, + sipL3PDUErrorTimeStamp + TimeTicks + } + + sipL3PDUErrorIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object identifies the SIP port + interface for which this entry contains management + information. The value of this object for a + particular interface has the same value as the + + + +SNMP Working Group [Page 21] + +RFC 1304 SIP Objects February 1992 + + + ifIndex object, defined in RFC 1156 and RFC 1213, + for the same interface." + ::= { sipL3PDUErrorEntry 1 } + + sipL3PDUErrorType OBJECT-TYPE + SYNTAX INTEGER { + erroredDAFieldFormat (1), + erroredSAFieldFormat (2), + invalidBAsizeFieldValue (3), + invalidHdrExtLength (4), + invalidHdrExtElementLength (5), + invalidHdrExtVersionElementPositionLenthOrValue (6), + invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7), + hePADError (8), + beTagMismatch (9), + baSizeFieldNotEqualToLengthField (10), + incorrectLength (11), + mriTimeout (12) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The type of error." + ::= { sipL3PDUErrorEntry 2 } + + sipL3PDUErrorSA OBJECT-TYPE + SYNTAX SMDSAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A rejected SMDS source address." + ::= { sipL3PDUErrorEntry 3 } + + sipL3PDUErrorDA OBJECT-TYPE + SYNTAX SMDSAddress + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A rejected SMDS destination address." + ::= { sipL3PDUErrorEntry 4 } + + sipL3PDUErrorTimeStamp OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The timestamp for the service disagreement. The + timestamp contains the value of sysUpTime at the + + + +SNMP Working Group [Page 22] + +RFC 1304 SIP Objects February 1992 + + + latest occurrence of this type of service + disagreement. See textual description under + sipL3PDUErrorTable for boundary conditions." + ::= { sipL3PDUErrorEntry 5 } + + END + +5. Acknowledgments + + This document was produced by the SNMP Working Group. In addition, + the comments of the following individuals are also acknowledged: Ted + Brunner, Jeff Case, Tracy Cox, Sherri Hiller, Steve Jaffe, Deirdre + Kostick, Dave Piscitello, and Ron Reuss. + +6. References + + [1] Cerf, V., "IAB Recommendations for the Development of Internet + Network Management Standards", RFC 1052, NRI, April 1988. + + [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review + Group", RFC 1109, NRI, August 1989. + + [3] Rose M., and K. McCloghrie, "Structure and Identification of + Management Information for TCP/IP-based internets", RFC 1155, + Performance Systems International, Hughes LAN Systems, May 1990. + + [4] McCloghrie K., and M. Rose, "Management Information Base for + Network Management of TCP/IP-based internets", RFC 1156, Hughes + LAN Systems, Performance Systems International, May 1990. + + [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple + Network Management Protocol", RFC 1157, SNMP Research, + Performance Systems International, Performance Systems + International, MIT Laboratory for Computer Science, May 1990. + + [6] McCloghrie K., and M. Rose, Editors, "Management Information + Base for Network Management of TCP/IP-based internets", RFC + 1213, Performance Systems International, March 1991. + + [7] Information processing systems - Open Systems Interconnection - + Specification of Abstract Syntax Notation One (ASN.1), + International Organization for Standardization, International + Standard 8824, December 1987. + + [8] Information processing systems - Open Systems Interconnection - + Specification of Basic Encoding Rules for Abstract Notation One + (ASN.1), International Organization for Standardization, + International Standard 8825, December 1987. + + + +SNMP Working Group [Page 23] + +RFC 1304 SIP Objects February 1992 + + + [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", + RFC 1212, Performance Systems International, Hughes LAN Systems, + March 1991. + + [10] Rose, M., Editor, "A Convention for Defining Traps for use with + the SNMP", RFC 1215, Performance Systems International, March + 1991. + + [11] "Generic System Requirements in Support of Switched Multi- + megabit Data Service", Bellcore Technical Reference, TR-TSV- + 000772, Issue 1, May 1991. + + [12] "Local Access System Generic Requirements, Objectives, and + Interfaces in Support of Switched Multi-megabit Data Service", + Bellcore Technical Reference, TR-TSV-000773, Issue 1, June 1990. + + [13] Baker F., and C. Kolb, Editors, "Definitions of Managed Objects + for the DS1 Interface Type", RFC 1232, ACC, Performance Systems + International, Inc., May 1991. + + [14] Cox, T., and K. Tesink, Editors, "Definitions of Managed Objects + for the DS3 Interface Type", RFC 1233, Bell Communications + Research, May 1991. + + [15] Piscitello, D., and J. Lawrence, Editors, The Transmission of IP + Datagrams over the SMDS Service", RFC 1209, Bell Communications + Research, March 1991. + + [16] "Generic Requirements For SMDS Customer Network Management + Service", TA-TSV-001062, Issue 1, February 1991, and Supplement + 1, April 1991. + + [17] Reynolds, J., "Reassignment of Experimental MIBs to Standard + MIBs", RFC 1239, USC/Information Sciences Institute, June 1991. + + [18] Tesink, K., "Definitions of Managed Objects for SMDS + Subscription", Version 1.0, Bellcore, March 1991. + + + + + + + + + + + + + + +SNMP Working Group [Page 24] + +RFC 1304 SIP Objects February 1992 + + +7. Security Considerations + + Security issues are not discussed in this memo. + +8. Authors' Addresses + + Tracy A. Cox + Bell Communications Research + 331 Newman Springs Road + Red Bank, NJ 07701 + + Phone: (908) 758-2107 + EMail: tacox@sabre.bellcore.com + + + Kaj Tesink + Bell Communications Research + 331 Newman Springs Road + Red Bank, NJ 07701 + + Phone: (908) 758-5254 + EMail: kaj@nvuxr.cc.bellcore.com + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +SNMP Working Group [Page 25] +
\ No newline at end of file |