+Network Working Group T. Cox
+Request For Comments: 1304 K. Tesink
+ Editors
+ Bell Communications Research
+ February 1992
+
+
+ Definitions of Managed Objects
+ for the SIP Interface Type
+
+Status of this Memo
+
+ This RFC specifies an IAB standards track protocol for the Internet
+ community, and requests discussion and suggestions for improvements.
+ Please refer to the current edition of the "IAB Official Protocol
+ Standards" for the standardization state and status of this protocol.
+ Distribution of this memo is unlimited.
+
+Abstract
+
+ This memo defines a portion of the Management Information Base (MIB)
+ for use with network management protocols in TCP/IP-based internets.
+ In particular, it defines objects for managing SIP (SMDS Interface
+ Protocol) objects.
+
+Table of Contents
+
+ 1. The Network Management Framework ............................ 2
+ 2. Objects ..................................................... 2
+ 2.1 Format of Definitions ...................................... 3
+ 3. Overview .................................................... 3
+ 4. Object Definitions .......................................... 4
+ 4.1 The SIP Level 3 group ...................................... 4
+ 4.2 The SIP Level 2 group ...................................... 8
+ 4.3 The SIP PLCP group ......................................... 11
+ 4.3.1 The SIP DS1 PLCP group ................................... 12
+ 4.3.2 The SIP DS3 PLCP group ................................... 14
+ 4.4 The SMDS Applications group ................................ 16
+ 4.5 The SMDS Carrier Selection group ........................... 18
+ 4.6 The SIP Error Log group .................................... 18
+ 5. Acknowledgments ............................................. 23
+ 6. References .................................................. 23
+ 7. Security Considerations...................................... 25
+ 8. Authors' Addresses........................................... 25
+
+
+
+
+
+
+
+SNMP Working Group [Page 1]
+
+RFC 1304 SIP Objects February 1992
+
+
+1. The Network Management Framework
+
+ The Internet-standard Network Management Framework consists of three
+ components. They are:
+
+ RFC 1155 [3] which defines the SMI, the mechanisms used for
+ describing and naming objects for the purpose of management. RFC
+ 1212 [9] defines a more concise description mechanism, which is
+ wholly consistent with the SMI.
+
+ RFC 1156 [4] which defines MIB-I, the core set of managed objects
+ for the Internet suite of protocols. RFC 1213 [6], defines MIB-
+ II, an evolution of MIB-I based on implementation experience and
+ new operational requirements.
+
+ RFC 1157 [5] which defines the SNMP, the protocol used for network
+ access to managed objects.
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+2. Objects
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation One (ASN.1)
+ International Standard 8824 [7] defined in the SMI. In particular,
+ each object has a name, a syntax, and an encoding. The name is an
+ object identifier, an administratively assigned name, which specifies
+ an object type. The object type together with an object instance
+ serves to uniquely identify a specific instantiation of the object.
+ For human convenience, we often use a textual string, termed the
+ OBJECT DESCRIPTOR, to also refer to the object type.
+
+ The syntax of an object type defines the abstract data structure
+ corresponding to that object type. The ASN.1 language is used for
+ this purpose. However, the SMI RFC 1155 [3] purposely restricts the
+ ASN.1 constructs which may be used. These restrictions are
+ explicitly made for simplicity.
+
+ The encoding of an object type is simply how that object type is
+ represented using the object type's syntax. Implicitly tied to the
+ notion of an object type's syntax and encoding is how the object type
+ is represented when being transmitted on the network. The SMI
+ specifies the use of the basic encoding rules of ASN.1 International
+ Standard 8825 [8], subject to the additional requirements imposed by
+ the SNMP.
+
+
+
+
+SNMP Working Group [Page 2]
+
+RFC 1304 SIP Objects February 1992
+
+
+2.1. Format of Definitions
+
+ Section 4 contains contains the specification of all object types
+ contained in this MIB module. The object types are defined using the
+ conventions defined in the SMI, as amended by the extensions
+ specified in RFC 1212 [9].
+
+3. Overview
+
+ These objects are used when the particular media being used to
+ realize an interface is a SIP interface. At present, this applies to
+ these values of the ifType variable in the Internet-standard MIB:
+
+ sip (31)
+
+ For these interfaces, the value of the ifSpecific variable in the
+ MIB-II [6] has the OBJECT IDENTIFIER value:
+
+ sip OBJECT IDENTIFIER ::= { transmission 31 }
+
+ The definitions contained herein are based on the SIP specifications
+ in Bellcore TR-TSV-000772 and TR-TSV-000773 [11,12].
+
+ The SIP (SMDS Interface Protocol) protocol stack is defined as
+ follows in TR-TSV-000772 [11]:
+
+ ___________________
+ | |
+ | SIP Level 3 [11] |
+ |___________________|
+ | |
+ | SIP Level 2 [11] |
+ |___________________|
+ | |
+ | PLCP [12] |
+ |___________________|
+ | |
+ | DS1 or DS3 [12] |
+ |___________________|
+
+ The PLCP (Physical Layer Convergence Procedure) adapts the
+ capabilities of the transmission system (DS1 or DS3 formats) to the
+ service expected by SIP Level 2. Managed objects for DS1 and DS3
+ Interface Types are defined in RFC 1232 [13] and RFC 1233 [14]
+ respectively (and amended in RFC 1239 [17]), and can be utilized for
+ management of SIP interfaces. This document defines managed objects
+ for the remaining protocol levels of the SIP Interface Type. This
+ document does not specify objects for the management of subscription
+
+
+
+SNMP Working Group [Page 3]
+
+RFC 1304 SIP Objects February 1992
+
+
+ or configuration of Subscriber-Network Interfaces (SNIs). Those
+ objects are defined in Definitions of Managed Objects for SMDS
+ Subscription [18]. Bellcore requirements on these objects are
+ specified in TA-TSV-001062 [16].
+
+4. Object Definitions
+
+ RFC1304-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ Counter, TimeTicks, IpAddress
+ FROM RFC1155-SMI
+ transmission
+ FROM RFC1213-MIB
+ OBJECT-TYPE
+ FROM RFC-1212;
+
+ -- This MIB module uses the extended OBJECT-TYPE macro
+ -- as defined in RFC-1212.
+
+ -- This is the MIB module for the SIP objects.
+
+
+ sip OBJECT IDENTIFIER ::= { transmission 31 }
+
+ -- All representations of SMDS addresses in this MIB
+ -- module use, as a textual convention (i.e., this
+ -- convention does not affect their encoding), the
+ -- data type:
+
+ SMDSAddress ::= OCTET STRING (SIZE (8))
+ -- the 60-bit SMDS address, preceded by 4 bits with the
+ -- following values:
+ -- "1100" when representing an individual address
+ -- "1110" when representing a group address
+
+
+ -- The SIP Level 3 group
+ -- Implementation of the SIP Level 3 group is mandatory
+ -- for all systems implementing SIP Level 3.
+
+ sipL3Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL3Entry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains SIP L3 parameters and
+ state variables, one entry per SIP port."
+
+
+
+SNMP Working Group [Page 4]
+
+RFC 1304 SIP Objects February 1992
+
+
+ ::= { sip 1 }
+
+ sipL3Entry OBJECT-TYPE
+ SYNTAX SipL3Entry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This list contains SIP L3 parameters and
+ state variables."
+ INDEX { sipL3Index }
+ ::= { sipL3Table 1 }
+
+ SipL3Entry ::= SEQUENCE {
+ sipL3Index
+ INTEGER,
+ sipL3ReceivedIndividualDAs
+ Counter,
+ sipL3ReceivedGAs
+ Counter,
+ sipL3UnrecognizedIndividualDAs
+ Counter,
+ sipL3UnrecognizedGAs
+ Counter,
+ sipL3SentIndividualDAs
+ Counter,
+ sipL3SentGAs
+ Counter,
+ sipL3Errors
+ Counter,
+ sipL3InvalidSMDSAddressTypes
+ Counter,
+ sipL3VersionSupport
+ INTEGER
+ }
+
+ sipL3Index OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP
+ port interface for which this entry contains
+ management information. The value of this
+ object for a particular interface has the same
+ value as the ifIndex object, defined in RFC
+ 1156 and RFC 1213, for the same interface."
+ ::= { sipL3Entry 1 }
+
+
+
+
+SNMP Working Group [Page 5]
+
+RFC 1304 SIP Objects February 1992
+
+
+ sipL3ReceivedIndividualDAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of individually addressed SIP
+ Level 3 PDUs received from the remote system
+ across the SNI. The total includes only
+ unerrored L3PDUs."
+ ::= { sipL3Entry 2 }
+
+ sipL3ReceivedGAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of group addressed SIP Level 3
+ PDUs received from the remote system across the
+ SNI. The total includes only unerrored L3PDUs."
+ ::= { sipL3Entry 3 }
+
+ sipL3UnrecognizedIndividualDAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+ remote system with invalid or unknown individual
+ destination addresses (Destination Address
+ Screening violations are not included). See SMDS
+ Subscription MIB module."
+ ::= { sipL3Entry 4 }
+
+ sipL3UnrecognizedGAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+ remote system with invalid or unknown group
+ addresses. (Destination Address Screening
+ violations are not included). See SMDS
+ Subscription MIB module."
+ ::= { sipL3Entry 5 }
+
+ sipL3SentIndividualDAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+
+
+
+SNMP Working Group [Page 6]
+
+RFC 1304 SIP Objects February 1992
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "The number of individually addressed SIP Level 3
+ PDUs that have been sent by this system across the
+ SNI."
+ ::= { sipL3Entry 6 }
+
+ sipL3SentGAs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of group addressed SIP L3PDUs that
+ have been sent by this system across the SNI."
+ ::= { sipL3Entry 7 }
+
+ -- The total number of SIP L3PDU errors can be calculated as
+ -- (Syntactic errors + Semantic Service errors )
+ -- Syntactic errors include:
+ -- sipL3Errors
+ -- Latest occurrences of syntactic error types are logged in
+ -- sipL3PDUErrorTable.
+ -- Semantic Service errors include:
+ -- sipL3UnrecognizedIndividualDAs
+ -- sipL3UnrecognizedGAs
+ -- sipL3InvalidSMDSAddressTypes
+ -- Note that public networks supporting SMDS may discard
+ -- SIP L3PDUs due to subscription violations. Related
+ -- managed objects are defined in Definitions of Managed
+ -- Objects for SMDS Subscription.
+
+
+ sipL3Errors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of SIP Level 3 PDUs received
+ from the remote system that were discovered to
+ have errors (including protocol processing and bit
+ errors but excluding addressing-related errors)
+ and were discarded. Includes both group addressed
+ L3PDUs and L3PDUs containing an individual
+ destination address."
+ ::= { sipL3Entry 8 }
+
+
+
+
+
+
+SNMP Working Group [Page 7]
+
+RFC 1304 SIP Objects February 1992
+
+
+ sipL3InvalidSMDSAddressTypes OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+ remote system that had the Source or Destination
+ Address_Type subfields, (the four most significant
+ bits of the 64 bit address field), not equal to
+ the value 1100 or 1110. Also, an error is
+ considered to have occurred if the Address_Type
+ field for a Source Address, the four most
+ significant bits of the 64 bits, is equal to 1110
+ (a group address)."
+ ::= { sipL3Entry 9 }
+
+ sipL3VersionSupport OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A value which indicates the version(s) of SIP
+ that this interface supports. The value is a sum.
+ This sum initially takes the value zero. For each
+ version, V, that this interface supports, 2 raised
+ to (V - 1) is added to the sum. For example, a
+ port supporting versions 1 and 2 would have a
+ value of (2^(1-1)+2^(2-1))=3. The
+ sipL3VersionSupport is effectively a bit mask with
+ Version 1 equal to the least significant bit
+ (LSB)."
+ ::= { sipL3Entry 10 }
+
+
+ -- The SIP Level 2 group
+ -- Implementation of the SIP Level 2 group is mandatory
+ -- for all systems implementing SIP Level 2.
+
+
+ sipL2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL2Entry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains SIP L2PDU parameters and
+ state variables, one entry per SIP port."
+ ::= { sip 2 }
+
+
+
+
+SNMP Working Group [Page 8]
+
+RFC 1304 SIP Objects February 1992
+
+
+ sipL2Entry OBJECT-TYPE
+ SYNTAX SipL2Entry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This list contains SIP L2 parameters and state
+ variables."
+ INDEX { sipL2Index }
+ ::= { sipL2Table 1 }
+
+ SipL2Entry ::= SEQUENCE {
+ sipL2Index
+ INTEGER,
+ sipL2ReceivedCounts
+ Counter,
+ sipL2SentCounts
+ Counter,
+ sipL2HcsOrCRCErrors
+ Counter,
+ sipL2PayloadLengthErrors
+ Counter,
+ sipL2SequenceNumberErrors
+ Counter,
+ sipL2MidCurrentlyActiveErrors
+ Counter,
+ sipL2BomOrSSMsMIDErrors
+ Counter,
+ sipL2EomsMIDErrors
+ Counter
+ }
+
+ sipL2Index OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP port
+ interface for which this entry contains management
+ information. The value of this object for a
+ particular interface has the same value as the
+ ifIndex object, defined in RFC 1156 and RFC 1213,
+ for the same interface."
+ ::= { sipL2Entry 1 }
+
+ sipL2ReceivedCounts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+
+
+
+SNMP Working Group [Page 9]
+
+RFC 1304 SIP Objects February 1992
+
+
+ DESCRIPTION
+ "The number of SIP Level 2 PDUs received from the
+ remote system across the SNI. The total includes
+ only unerrored L2PDUs."
+ ::= { sipL2Entry 2 }
+
+ sipL2SentCounts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of SIP Level 2 PDUs that have been
+ sent by this system across the SNI."
+ ::= { sipL2Entry 3 }
+
+ -- The total number of SIP L2PDU errors can be calculated as
+ -- the sum of:
+ -- sipL2HcsOrCRCErrors
+ -- sipL2PayloadLengthErrors
+ -- sipL2SequenceNumberErrors
+ -- sipL2MidCurrentlyActiveErrors
+ -- sipL2BomOrSSMsMIDErrors
+ -- sipL2EomsMIDErrors
+
+ sipL2HcsOrCRCErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that were
+ discovered to have either a Header Check Sequence
+ error or a Payload CRC violation."
+ ::= { sipL2Entry 4 }
+
+ sipL2PayloadLengthErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that had
+ Payload Length errors that fall in the following
+ specifications:
+ - SSM L2_PDU payload length field value less
+ - than 28 octets or greater than 44 octets,
+
+ - BOM or COM L2_PDU payload length field not
+ - equal to 44 octets,
+
+
+
+
+SNMP Working Group [Page 10]
+
+RFC 1304 SIP Objects February 1992
+
+
+ - EOM L2_PDU payload length field value less
+ - than 4 octets or greater than 44 octets."
+ ::= { sipL2Entry 5 }
+
+ sipL2SequenceNumberErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that had
+ a sequence number within the L2PDU not equal to
+ the expected sequence number of the SMDS SS
+ receive process."
+ ::= { sipL2Entry 6 }
+
+ sipL2MidCurrentlyActiveErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that are
+ BOMs for which an active receive process is
+ already started."
+ ::= { sipL2Entry 7 }
+
+ sipL2BomOrSSMsMIDErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that are
+ SSMs with a MID not equal to zero or are BOMs with
+ MIDs equal to zero."
+ ::= { sipL2Entry 8 }
+
+ sipL2EomsMIDErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that are
+ EOMs for which there is no active receive process
+ for the MID (i.e., the receipt of an EOM which
+ does not correspond to a BOM) OR the EOM has a MID
+ equal to zero."
+ ::= { sipL2Entry 9 }
+
+
+
+
+
+SNMP Working Group [Page 11]
+
+RFC 1304 SIP Objects February 1992
+
+
+ -- The SIP PLCP group
+ -- Implementation of one of these groups is mandatory
+ -- if the PLCP is implemented.
+
+ sipPLCP OBJECT IDENTIFIER ::= { sip 3 }
+
+
+ -- The SIP DS1 PLCP group
+ -- Implementation of this group is mandatory
+ -- if the DS1 PLCP is implemented.
+
+ sipDS1PLCPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipDS1PLCPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains SIP DS1 PLCP parameters and
+ state variables, one entry per SIP port."
+ ::= { sipPLCP 1 }
+
+ sipDS1PLCPEntry OBJECT-TYPE
+ SYNTAX SipDS1PLCPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This list contains SIP DS1 PLCP parameters and
+ state variables."
+ INDEX { sipDS1PLCPIndex }
+ ::= { sipDS1PLCPTable 1 }
+
+ SipDS1PLCPEntry ::= SEQUENCE {
+ sipDS1PLCPIndex
+ INTEGER,
+ sipDS1PLCPSEFSs
+ Counter,
+ sipDS1PLCPAlarmState
+ INTEGER,
+ sipDS1PLCPUASs
+ Counter
+ }
+
+
+ sipDS1PLCPIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP port
+
+
+
+SNMP Working Group [Page 12]
+
+RFC 1304 SIP Objects February 1992
+
+
+ interface for which this entry contains management
+ information. The value of this object for a
+ particular interface has the same value as the
+ ifIndex object, defined in RFC 1156 and RFC 1213,
+ for the same interface."
+ ::= { sipDS1PLCPEntry 1 }
+
+
+ sipDS1PLCPSEFSs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A DS1 Severely Errored Framing Second (SEFS) is a
+ count of one-second intervals containing one or
+ more SEF events. A Severely Errored Framing (SEF)
+ event is declared when an error in the A1 octet
+ and an error in the A2 octet of a framing octet
+ pair (i.e., errors in both framing octets), or two
+ consecutive invalid and/or nonsequential Path
+ Overhead Identifier octets are detected."
+ ::= { sipDS1PLCPEntry 2 }
+
+ sipDS1PLCPAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm (1),
+ receivedFarEndAlarm (2),
+ incomingLOF (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable indicates if there is an alarm
+ present for the DS1 PLCP. The value
+ receivedFarEndAlarm means that the DS1 PLCP has
+ received an incoming Yellow Signal, the value
+ incomingLOF means that the DS1 PLCP has declared a
+ loss of frame (LOF) failure condition, and the
+ value noAlarm means that there are no alarms
+ present. See TR-TSV-000773 for a description of
+ alarm states."
+ ::= { sipDS1PLCPEntry 3 }
+
+
+ sipDS1PLCPUASs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+
+
+
+SNMP Working Group [Page 13]
+
+RFC 1304 SIP Objects February 1992
+
+
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, as defined by TR-TSV-000773,
+ encountered by the PLCP."
+ ::= { sipDS1PLCPEntry 4 }
+
+
+ -- The SIP DS3 PLCP group
+ -- Implementation of this group is mandatory
+ -- if the DS3 PLCP is implemented.
+
+ sipDS3PLCPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipDS3PLCPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This table contains SIP DS3 PLCP parameters and
+ state variables, one entry per SIP port."
+ ::= { sipPLCP 2 }
+
+ sipDS3PLCPEntry OBJECT-TYPE
+ SYNTAX SipDS3PLCPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "This list contains SIP DS3 PLCP parameters and
+ state variables."
+ INDEX { sipDS3PLCPIndex }
+ ::= { sipDS3PLCPTable 1 }
+
+ SipDS3PLCPEntry ::= SEQUENCE {
+ sipDS3PLCPIndex
+ INTEGER,
+ sipDS3PLCPSEFSs
+ Counter,
+ sipDS3PLCPAlarmState
+ INTEGER,
+ sipDS3PLCPUASs
+ Counter
+ }
+
+
+ sipDS3PLCPIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP port
+
+
+
+SNMP Working Group [Page 14]
+
+RFC 1304 SIP Objects February 1992
+
+
+ interface for which this entry contains management
+ information. The value of this object for a
+ particular interface has the same value as the
+ ifIndex object, defined in RFC 1156 and RFC 1213,
+ for the same interface."
+ ::= { sipDS3PLCPEntry 1 }
+
+ sipDS3PLCPSEFSs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A DS3 Severely Errored Framing Second (SEFS) is a
+ count of one-second intervals containing one or
+ more SEF events. A Severely Errored Framing (SEF)
+ event is declared when an error in the A1 octet
+ and an error in the A2 octet of a framing octet
+ pair (i.e., errors in both framing octets), or two
+ consecutive invalid and/or nonsequential Path
+ Overhead Identifier octets are detected."
+ ::= { sipDS3PLCPEntry 2 }
+
+ sipDS3PLCPAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm (1),
+ receivedFarEndAlarm (2),
+ incomingLOF (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable indicates if there is an alarm
+ present for the DS3 PLCP. The value
+ receivedFarEndAlarm means that the DS3 PLCP has
+ received an incoming Yellow Signal, the value
+ incomingLOF means that the DS3 PLCP has declared a
+ loss of frame (LOF) failure condition, and the
+ value noAlarm means that there are no alarms
+ present. See TR-TSV-000773 for a description of
+ alarm states."
+ ::= { sipDS3PLCPEntry 3 }
+
+
+ sipDS3PLCPUASs OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+
+
+
+SNMP Working Group [Page 15]
+
+RFC 1304 SIP Objects February 1992
+
+
+ "The counter associated with the number of
+ Unavailable Seconds, as defined by TR-TSV-000773,
+ encountered by the PLCP."
+ ::= { sipDS3PLCPEntry 4 }
+
+
+ -- The SMDS Applications group
+ -- Applications that have been identified for this group are:
+ -- * IP-over-SMDS (details are specified in RFC 1209)
+ -- Implementation of this group is mandatory for systems
+ -- that implement IP-over-SMDS Interface Protocol.
+
+ smdsApplications OBJECT IDENTIFIER ::= { sip 4 }
+
+ ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }
+
+ -- Although the objects in this group are read-only, at the
+ -- agent's discretion they may be made read-write so that the
+ -- management station, when appropriately authorized, may
+ -- change the addressing information related to the
+ -- configuration of a logical IP subnetwork implemented on
+ -- top of SMDS.
+
+ -- This table is necessary to support RFC1209 (IP-over-SMDS)
+ -- and gives information on the Group Addresses and ARP
+ -- Addresses used in the Logical IP subnetwork.
+ -- One SMDS address may be associated with multiple IP
+ -- addresses. One SNI may be associated with multiple LISs.
+
+ ipOverSMDSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpOverSMDSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The table of addressing information relevant to
+ this entity's IP addresses."
+ ::= { ipOverSMDS 1 }
+
+ ipOverSMDSEntry OBJECT-TYPE
+ SYNTAX IpOverSMDSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The addressing information for one of this
+ entity's IP addresses."
+ INDEX { ipOverSMDSIndex, ipOverSMDSAddress }
+ ::= { ipOverSMDSTable 1 }
+
+
+
+
+SNMP Working Group [Page 16]
+
+RFC 1304 SIP Objects February 1992
+
+
+ IpOverSMDSEntry ::=
+ SEQUENCE {
+ ipOverSMDSIndex
+ INTEGER,
+ ipOverSMDSAddress
+ IpAddress,
+ ipOverSMDSHA
+ SMDSAddress,
+ ipOverSMDSLISGA
+ SMDSAddress,
+ ipOverSMDSARPReq
+ SMDSAddress
+ }
+
+ ipOverSMDSIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP port
+ interface for which this entry contains management
+ information. The value of this object for a
+ particular interface has the same value as the
+ ifIndex object, defined in RFC 1156 and RFC 1213,
+ for the same interface."
+ ::= { ipOverSMDSEntry 1 }
+
+ ipOverSMDSAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address to which this entry's addressing
+ information pertains."
+ ::= { ipOverSMDSEntry 2 }
+
+ ipOverSMDSHA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SMDS Individual address of the IP station."
+ ::= { ipOverSMDSEntry 3 }
+
+ ipOverSMDSLISGA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ ACCESS read-only
+ STATUS mandatory
+
+
+
+SNMP Working Group [Page 17]
+
+RFC 1304 SIP Objects February 1992
+
+
+ DESCRIPTION
+ "The SMDS Group Address that has been configured
+ to identify the SMDS Subscriber-Network Interfaces
+ (SNIs) of all members of the Logical IP Subnetwork
+ (LIS) connected to the network supporting SMDS."
+ ::= { ipOverSMDSEntry 4 }
+
+ ipOverSMDSARPReq OBJECT-TYPE
+ SYNTAX SMDSAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The SMDS address (individual or group) to which
+ ARP Requests are to be sent."
+ ::= { ipOverSMDSEntry 5 }
+
+
+ -- The SMDS Carrier Selection group
+ -- This group is used as a place holder
+ -- for carrier selection objects.
+
+ smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}
+
+
+ -- The SIP Error Log
+ -- Implementation of this group is mandatory
+ -- for all systems that implement SIP Level 3.
+
+ sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }
+
+ sipL3PDUErrorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL3PDUErrorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table that contains the latest occurrence of
+ the following syntactical SIP L3PDU errors:
+
+ - Destination Address Field Format Error,
+
+ The following pertains to the 60 least significant
+ bits of the 64 bit address field. The 60 bits
+ contained in the address subfield can be used to
+ represent addresses up to 15 decimal digits. Each
+ decimal digit shall be encoded into four bits
+ using Binary Coded Decimal (BCD), with the most
+ significant digit occurring left-most. If not all
+ 15 digits are required, then the remainder of this
+
+
+
+SNMP Working Group [Page 18]
+
+RFC 1304 SIP Objects February 1992
+
+
+ field shall be padded on the right with bits set
+ to one. An error is considered to have occurred:
+ a). if the first four bits of the address
+ subfield are not BCD, OR b). if the first four
+ bits of the address subfield are populated with
+ the country code value 0001, AND the 40 bits which
+ follow are not Binary Coded Decimal (BCD) encoded
+ values of the 10 digit addresses, OR the remaining
+ 16 least significant bits are not populated with
+ 1's, OR c). if the address subfield is not
+ correct according to another numbering plan which
+ is dependent upon the carrier assigning the
+ numbers and offering SMDS.
+
+ - Source Address Field Format Error,
+
+ The description of this parameter is the same as
+ the description of the Destination Address Field
+ Format Error.
+
+ - Invalid BAsize Field Value,
+
+ An error is considered to have occurred when the
+ BAsize field of an SIP L3PDU contains a value less
+ that 32, greater than 9220 octets without the
+ CRC32 field present, greater than 9224 octets with
+ the CRC32 field present, or not equal to a
+ multiple of 4 octets,
+
+ - Invalid Header Extension Length Field Value,
+
+ An error is considered to have occurred when the
+ Header Extension Length field value is not equal
+ 3.
+
+ - Invalid Header Extension - Element Length,
+
+ An error is considered to have occurred when the
+ Header Extension - Element Length is greater than
+ 12.
+
+ - Invalid Header Extension - Version Element
+ Position, Length, or Value,
+
+ An error is considered to have occurred when a
+ Version element with Length=3, Type=0, and Value=1
+ does not appear first within the Header Extension,
+ or an element Type=0 appears somewhere other than
+
+
+
+SNMP Working Group [Page 19]
+
+RFC 1304 SIP Objects February 1992
+
+
+ within the first three octets in the Header
+ Extension.
+
+ - Invalid Header Extension - Carrier Selection
+ Element Position, Length, Value or Format,
+
+ An error is considered to have occurred when a
+ Carrier Selection element does not appear second
+ within the Header Extension, if the Element Type
+ does not equal 1, the Element Length does not
+ equal 4, 6, or 8, the Element Value field is not
+ four BCD encoded decimal digits used in specifying
+ the Carrier Identification Code (CIC), or the
+ identified CIC code is invalid.
+
+ - Header Extension PAD Error
+
+ An error is considered to have occurred when the
+ Header Extension PAD is 9 octets in length, or if
+ the Header Extension PAD is greater than zero
+ octets in length and the Header Extension PAD does
+ not follow all Header Extension elements or does
+ not begin with at least one octet of all zeros.
+
+ - BEtag Mismatch Error,
+
+ An error is considered to have occurred when the
+ Beginning-End Tags in the SIP L3PDU header and
+ trailer are not equal.
+
+ - BAsize Field not equal to Length Field Error,
+
+ An error is considered to have occurred when the
+ value of the BAsize Field does not equal the value
+ of the Length Field.
+
+ - Incorrect Length Error, and
+
+ An error is considered to have occurred when the
+ the Length field value is not equal to the portion
+ of the SIP L3PDU which extends from the
+ Destination Address field up to and including the
+ CRC32 field (if present) or up to and including
+ the PAD field (if the CRC32 field is not present).
+ As an optional check, an error is considered to
+ have occurred when the length of a partially
+ received SIP L3PDU exceeds the BAsize value.
+
+
+
+
+SNMP Working Group [Page 20]
+
+RFC 1304 SIP Objects February 1992
+
+
+ - MRI Timeout Error.
+
+ An error is considered to have occurred when the
+ elapsed time between receipt of BOM and
+ corresponding EOM exceeds the value of the MRI
+ (Message Receive Interval) for a particular
+ transport signal format.
+
+ An entry is indexed by interface number and error
+ type, and contains Source Address, Destination
+ Address and a timestamp. All these errors are
+ counted in the sipL3Errors counter. When
+ sipL3PDUErrorTimeStamp is equal to zero, the
+ SipL3PDUErrorEntry does not contain any valid
+ information."
+ ::= { sipErrorLog 1 }
+
+ sipL3PDUErrorEntry OBJECT-TYPE
+ SYNTAX SipL3PDUErrorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the service disagreement table."
+ INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType }
+ ::= { sipL3PDUErrorTable 1 }
+
+ SipL3PDUErrorEntry ::= SEQUENCE {
+ sipL3PDUErrorIndex
+ INTEGER,
+ sipL3PDUErrorType
+ INTEGER,
+ sipL3PDUErrorSA
+ SMDSAddress,
+ sipL3PDUErrorDA
+ SMDSAddress,
+ sipL3PDUErrorTimeStamp
+ TimeTicks
+ }
+
+ sipL3PDUErrorIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the SIP port
+ interface for which this entry contains management
+ information. The value of this object for a
+ particular interface has the same value as the
+
+
+
+SNMP Working Group [Page 21]
+
+RFC 1304 SIP Objects February 1992
+
+
+ ifIndex object, defined in RFC 1156 and RFC 1213,
+ for the same interface."
+ ::= { sipL3PDUErrorEntry 1 }
+
+ sipL3PDUErrorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ erroredDAFieldFormat (1),
+ erroredSAFieldFormat (2),
+ invalidBAsizeFieldValue (3),
+ invalidHdrExtLength (4),
+ invalidHdrExtElementLength (5),
+ invalidHdrExtVersionElementPositionLenthOrValue (6),
+ invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7),
+ hePADError (8),
+ beTagMismatch (9),
+ baSizeFieldNotEqualToLengthField (10),
+ incorrectLength (11),
+ mriTimeout (12)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of error."
+ ::= { sipL3PDUErrorEntry 2 }
+
+ sipL3PDUErrorSA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A rejected SMDS source address."
+ ::= { sipL3PDUErrorEntry 3 }
+
+ sipL3PDUErrorDA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A rejected SMDS destination address."
+ ::= { sipL3PDUErrorEntry 4 }
+
+ sipL3PDUErrorTimeStamp OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The timestamp for the service disagreement. The
+ timestamp contains the value of sysUpTime at the
+
+
+
+SNMP Working Group [Page 22]
+
+RFC 1304 SIP Objects February 1992
+
+
+ latest occurrence of this type of service
+ disagreement. See textual description under
+ sipL3PDUErrorTable for boundary conditions."
+ ::= { sipL3PDUErrorEntry 5 }
+
+ END
+
+5. Acknowledgments
+
+ This document was produced by the SNMP Working Group. In addition,
+ the comments of the following individuals are also acknowledged: Ted
+ Brunner, Jeff Case, Tracy Cox, Sherri Hiller, Steve Jaffe, Deirdre
+ Kostick, Dave Piscitello, and Ron Reuss.
+
+6. References
+
+ [1] Cerf, V., "IAB Recommendations for the Development of Internet
+ Network Management Standards", RFC 1052, NRI, April 1988.
+
+ [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
+ Group", RFC 1109, NRI, August 1989.
+
+ [3] Rose M., and K. McCloghrie, "Structure and Identification of
+ Management Information for TCP/IP-based internets", RFC 1155,
+ Performance Systems International, Hughes LAN Systems, May 1990.
+
+ [4] McCloghrie K., and M. Rose, "Management Information Base for
+ Network Management of TCP/IP-based internets", RFC 1156, Hughes
+ LAN Systems, Performance Systems International, May 1990.
+
+ [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
+ Network Management Protocol", RFC 1157, SNMP Research,
+ Performance Systems International, Performance Systems
+ International, MIT Laboratory for Computer Science, May 1990.
+
+ [6] McCloghrie K., and M. Rose, Editors, "Management Information
+ Base for Network Management of TCP/IP-based internets", RFC
+ 1213, Performance Systems International, March 1991.
+
+ [7] Information processing systems - Open Systems Interconnection -
+ Specification of Abstract Syntax Notation One (ASN.1),
+ International Organization for Standardization, International
+ Standard 8824, December 1987.
+
+ [8] Information processing systems - Open Systems Interconnection -
+ Specification of Basic Encoding Rules for Abstract Notation One
+ (ASN.1), International Organization for Standardization,
+ International Standard 8825, December 1987.
+
+
+
+SNMP Working Group [Page 23]
+
+RFC 1304 SIP Objects February 1992
+
+
+ [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
+ RFC 1212, Performance Systems International, Hughes LAN Systems,
+ March 1991.
+
+ [10] Rose, M., Editor, "A Convention for Defining Traps for use with
+ the SNMP", RFC 1215, Performance Systems International, March
+ 1991.
+
+ [11] "Generic System Requirements in Support of Switched Multi-
+ megabit Data Service", Bellcore Technical Reference, TR-TSV-
+ 000772, Issue 1, May 1991.
+
+ [12] "Local Access System Generic Requirements, Objectives, and
+ Interfaces in Support of Switched Multi-megabit Data Service",
+ Bellcore Technical Reference, TR-TSV-000773, Issue 1, June 1990.
+
+ [13] Baker F., and C. Kolb, Editors, "Definitions of Managed Objects
+ for the DS1 Interface Type", RFC 1232, ACC, Performance Systems
+ International, Inc., May 1991.
+
+ [14] Cox, T., and K. Tesink, Editors, "Definitions of Managed Objects
+ for the DS3 Interface Type", RFC 1233, Bell Communications
+ Research, May 1991.
+
+ [15] Piscitello, D., and J. Lawrence, Editors, The Transmission of IP
+ Datagrams over the SMDS Service", RFC 1209, Bell Communications
+ Research, March 1991.
+
+ [16] "Generic Requirements For SMDS Customer Network Management
+ Service", TA-TSV-001062, Issue 1, February 1991, and Supplement
+ 1, April 1991.
+
+ [17] Reynolds, J., "Reassignment of Experimental MIBs to Standard
+ MIBs", RFC 1239, USC/Information Sciences Institute, June 1991.
+
+ [18] Tesink, K., "Definitions of Managed Objects for SMDS
+ Subscription", Version 1.0, Bellcore, March 1991.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+SNMP Working Group [Page 24]
+
+RFC 1304 SIP Objects February 1992
+
+
+7. Security Considerations
+
+ Security issues are not discussed in this memo.
+
+8. Authors' Addresses
+
+ Tracy A. Cox
+ Bell Communications Research
+ 331 Newman Springs Road
+ Red Bank, NJ 07701
+
+ Phone: (908) 758-2107
+ EMail: tacox@sabre.bellcore.com
+
+
+ Kaj Tesink
+ Bell Communications Research
+ 331 Newman Springs Road
+ Red Bank, NJ 07701
+
+ Phone: (908) 758-5254
+ EMail: kaj@nvuxr.cc.bellcore.com
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+SNMP Working Group [Page 25]
+ \ No newline at end of file