summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc1407.txt
diff options
context:
space:
mode:
Diffstat (limited to 'doc/rfc/rfc1407.txt')
-rw-r--r--doc/rfc/rfc1407.txt2411
1 files changed, 2411 insertions, 0 deletions
diff --git a/doc/rfc/rfc1407.txt b/doc/rfc/rfc1407.txt
new file mode 100644
index 0000000..d3165db
--- /dev/null
+++ b/doc/rfc/rfc1407.txt
@@ -0,0 +1,2411 @@
+
+
+
+
+
+
+Network Working Group T. Cox
+Request for Comments: 1407 K. Tesink
+Obsoletes: 1233 Bell Communications Research
+ Editors
+ January 1993
+
+
+ Definitions of Managed Objects
+ for the DS3/E3 Interface Type
+
+Status of this Memo
+
+ This RFC specifies an IAB standards track protocol for the Internet
+ community, and requests discussion and suggestions for improvements.
+ Please refer to the current edition of the "IAB Official Protocol
+ Standards" for the standardization state and status of this protocol.
+ Distribution of this memo is unlimited.
+
+Abstract
+
+ This memo defines an extension to the Management Information Base
+ (MIB) for use with network management protocols in TCP/IP-based
+ internets. In particular, it defines objects for managing DS3 and E3
+ Interfaces. This document is a companion document with Definitions
+ of Managed Objects for the DS1 Interface Type.
+
+ This document entirely replaces RFC 1233, which contains a
+ fundamental error: many objects are encoded as Counters that must be
+ encoded as INTEGERs or Gauges. The magnitude of the change required
+ is sufficient that virtually every object changed. Therefore, the
+ MIB documented in RFC 1233 should not be implemented.
+
+Table of Contents
+
+ 1. The Network Management Framework ...................... 2
+ 2. Objects ............................................... 2
+ 2.1 Format of Definitions ................................ 3
+ 2.2 Changes from RFC 1233 ................................ 3
+ 3. Overview .............................................. 5
+ 3.1 Binding between ifIndex and DS3/E3 Interfaces ........ 5
+ 3.2 Objectives of this MIB Module ........................ 7
+ 3.3 DS3/E3 Terminology ................................... 7
+ 3.3.1 Error Events ....................................... 7
+ 3.3.2 Performance Parameters ............................. 8
+ 3.3.3 Performance Defects ................................ 10
+ 3.3.4 Other Terms ........................................ 11
+ 4. Object Definitions .................................... 12
+ 4.1 The DS3/E3 Near End Group ............................ 12
+
+
+
+Trunk MIB Working Group [Page 1]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ 4.1.1 The DS3/E3 Configuration ........................... 12
+ 4.1.2 The DS3/E3 Current ................................. 18
+ 4.1.3 The DS3/E3 Interval ................................ 21
+ 4.1.4 The DS3/E3 Total ................................... 25
+ 4.2 The DS3 Far End Group ................................ 29
+ 4.2.1 The DS3 Far End Configuration ...................... 29
+ 4.2.2 The DS3 Far End Current ............................ 31
+ 4.2.3 The DS3 Far End Interval ........................... 34
+ 4.2.4 The DS3 Far End Total .............................. 36
+ 4.3 The DS3/E3 Fractional Group .......................... 38
+ 5. Acknowledgments ....................................... 41
+ 6. References ............................................ 41
+ 7. Security Considerations ............................... 43
+ 8. Authors' Addresses .................................... 43
+
+1. The Network Management Framework
+
+ The Internet-standard Network Management Framework consists of three
+ components. They are:
+
+ STD 16/RFC 1155 which defines the SMI, the mechanisms used for
+ describing and naming objects for the purpose of management. STD
+ 16/RFC 1212 defines a more concise description mechanism, which is
+ wholly consistent with the SMI.
+
+ RFC 1156 which defines MIB-I, the core set of managed objects for
+ the Internet suite of protocols. STD 17/RFC 1213, defines MIB-II,
+ an evolution of MIB-I based on implementation experience and new
+ operational requirements.
+
+ STD 15/RFC 1157 which defines the SNMP, the protocol used for
+ network access to managed objects.
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+2. Objects
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation One (ASN.1) [7]
+ defined in the SMI. In particular, each object has a name, a syntax,
+ and an encoding. The name is an object identifier, an
+ administratively assigned name, which specifies an object type. The
+ object type together with an object instance serves to uniquely
+ identify a specific instantiation of the object. For human
+ convenience, we often use a textual string, termed the OBJECT
+ DESCRIPTOR, to also refer to the object type.
+
+
+
+Trunk MIB Working Group [Page 2]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ The syntax of an object type defines the abstract data structure
+ corresponding to that object type. The ASN.1 language is used for
+ this purpose. However, the SMI [3] purposely restricts the ASN.1
+ constructs which may be used. These restrictions are explicitly made
+ for simplicity.
+
+ The encoding of an object type is simply how that object type is
+ represented using the object type's syntax. Implicitly tied to the
+ notion of an object type's syntax and encoding is how the object type
+ is represented when being transmitted on the network. The SMI
+ specifies the use of the basic encoding rules of ASN.1 [8], subject
+ to the additional requirements imposed by the SNMP.
+
+2.1. Format of Definitions
+
+ Section 4 contains contains the specification of all object types
+ contained in this MIB module. The object types are defined using the
+ conventions defined in the SMI, as amended by the extensions
+ specified in STD 16, RFC 1212 [13].
+
+2.2. Changes from RFC 1233
+
+ This MIB obsoletes RFC 1233. The changes from RFC 1233 are the
+ following:
+
+ -- This MIB module contains information to manage
+ an E3 interface, also.
+
+ -- This MIB module contains three groups:
+ DS3/E3 Near End Group which is mandatory,
+ DS3 Far End Group which is optional, and
+ DS3 Fractional Group which is optional.
+
+ -- The DS3 Far End Group is a new group and contains
+ configuration information and statistics
+ that are collected from the far end DS3/E3 interface.
+ Presently, the Far End Group may only be implemented by
+ DS3 systems that use C-bit Parity or SYNTRAN.
+
+ -- The DS3 Fractional Group is a new group and is
+ modeled after the DS1 Fractional Group.
+
+ -- ds3CSUIndex has been redefined and renamed
+ to dsx3LineIndex. This object
+ is the identifier of a DS3/E3 Interface on a device.
+ On a CSU, a single DS3/E3 data stream will cross two DS3/E3
+ interfaces, which have separate dsx3LineIndex values.
+
+
+
+
+Trunk MIB Working Group [Page 3]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ -- ds3Index has been redefined and renamed to
+ dsx3IfIndex. This value for this
+ object is equal to the value of ifIndex from the Interfaces
+ table of MIB II (STD 17, RFC 1213).
+
+ -- The ACCESS for objects in the dsx3ConfigTable has
+ been set to read-write for items that are configurable.
+
+ -- The dsx3ZeroCoding has been renamed to dsx3LineCoding.
+
+ -- A new object has been added called dsx3LoopbackConfig,
+ which better describes the loopback capabilities of
+ a DS3/E3 interface on a device.
+
+ -- The dsx3SendCode object has been updated to reflect
+ different types of loopback messages.
+
+ -- A new object has been added called dsx3LineStatus.
+ This object better describes the status (e.g.,
+ failure state and loopback state) of a
+ DS3/E3 interface.
+
+ -- A new object has been added called dsx3TransmitClockSource.
+ This object identifies the source for the transmit clock.
+
+ -- All Counters have been changed to Gauges.
+
+ -- A Line Errored Seconds object has been added to
+ all near end tables.
+
+ -- Line Coding Violations are counted instead of Bipolar
+ Violations.
+
+ -- A new Coding Violation counter has been added to count
+ coding violations reported via the C-bits of SYNTRAN
+ and C-bit Parity DS3 applications.
+ The original Coding Violation counter has been renamed
+ to PCV to mean coding violations reported via the P-bits.
+ This count is also added for symmetry with the far end
+ statistics.
+
+ -- A new Errored Second counter and Severely Errored Second
+ counter has been added to count these performance events
+ via the C-bits of the SYNTRAN and C-bit Parity DS3
+ applications. The original ES and SES counters have been
+ renamed to PES and PSES to mean reported via the P-bits.
+ These counts are also added for symmetry with the far end
+ statistics.
+
+
+
+Trunk MIB Working Group [Page 4]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+3. Overview
+
+ These objects are used when the particular media being used to
+ realize an interface is a DS3/E3 interface. At present, this applies
+ to these values of the ifType variable in the Internet-standard MIB:
+
+ ds3 (30)
+
+ The DS3 definitions contained herein are based on the DS3
+ specifications in ANSI T1.102-1987, ANSI T1.107-1988, ANSI T1.107a-
+ 1990, and ANSI T1.404-1989 [9,10,10a,11]. The E3 definitions
+ contained herein are based on the E3 specifications in CCITT G.751
+ [14].
+
+3.1. Binding between ifIndex and DS3/E3 Interfaces
+
+ Different physical configurations for the support of SNMP with DS3/E3
+ equipment exist. To accommodate these scenarios, two different
+ indices for DS3/E3 interfaces are introduced in this MIB. These
+ indices are dsx3IfIndex and dsx3LineIndex.
+
+ External interface scenario: the SNMP Agent represents all managed
+ DS3/E3 lines as external interfaces (for example, an Agent residing
+ on the device supporting DS3/E3 interfaces directly):
+
+ For this scenario, all interfaces are assigned an integer value equal
+ to ifIndex, and the following applies:
+
+ ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces.
+
+ The dsx3IfIndex column of the DS3/E3 Configuration table relates each
+ DS3/E3 interface to its corresponding interface (ifIndex) in the
+ Internet-standard MIB (MIB-II STD 17, RFC 1213).
+
+ External&Internal interface scenario: the SNMP Agents resides on an
+ host external from the device supporting DS3/E3 interfaces (e.g., a
+ router). The Agent represents both the host and the DS3/E3 device.
+ The index dsx3LineIndex is used to not only represent the DS3/E3
+ interfaces external from the host/DS3/E3-device combination, but also
+ the DS3/E3 interfaces connecting the host and the DS3/E3 device. The
+ index dsx3IfIndex is always equal to ifIndex.
+
+ Example:
+
+ A shelf full of CSUs connected to a Router. An SNMP Agent residing on
+ the router proxies for itself and the CSU. The router has also an
+ Ethernet interface:
+
+
+
+
+Trunk MIB Working Group [Page 5]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ +-----+
+ | | |
+ | | | +---------------------+
+ |E | | 44.736 MBPS | ds3 M13 Line#A | ds3 C-bit Parity
+ |t | R |---------------+ - - - - - - - - - +------>
+ |h | | | |
+ |e | O | 44.736 MBPS | ds3 M13 Line#B | ds3 C-bit Parity
+ |r | |---------------+ - - - - - - - - - - +------>
+ |n | U | | |
+ |e | | 44.736 MBPS | ds3 M13 Line#C | ds3 C-bit Parity
+ |t | T |---------------+ - - - -- -- - - - - +------>
+ | | | | |
+ |-----| E | 44.736 MBPS | ds3 M13 Line#D | ds3 C-bit Parity
+ | | |---------------+ - - - - -- - - - - +------>
+ | | R | |_____________________|
+ | | |
+ | +-----+
+
+ The assignment of the index values could for example be:
+
+ ifIndex (= dsx3IfIndex) dsx3LineIndex
+
+ 1 NA NA (Ethernet)
+ 2 Line#A Router Side 6
+ 2 Line#A Network Side 7
+ 3 Line#B Router Side 8
+ 3 Line#B Network Side 9
+ 4 Line#C Router Side 10
+ 4 Line#C Network Side 11
+ 5 Line#D Router Side 12
+ 5 Line#D Network Side 13
+
+ For this example, ifNumber is equal to 5. Note the following
+ description of dsx3LineIndex: the dsx3LineIndex identifies a DS3/E3
+ Interface on a managed device. If there is an ifEntry that is
+ directly associated with this and only this DS3/E3 interface, it
+ should have the same value as ifIndex. Otherwise, number the
+ dsx3LineIndices with an unique identifier following the rules of
+ choosing a number greater than ifNumber and numbering inside
+ interfaces (e.g., equipment side) with even numbers and outside
+ interfaces (e.g., network side) with odd numbers.
+
+ If the CSU shelf is managed by itself by a local SNMP Agent, the
+ situation would be:
+
+
+
+
+
+
+
+Trunk MIB Working Group [Page 6]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ifIndex (= dsx3IfIndex) dsx3LineIndex
+
+ 1 Line#A Network Side 1
+ 2 Line#A RouterSide 2
+ 3 Line#B Network Side 3
+ 4 Line#B RouterSide 4
+ 5 Line#C Network Side 5
+ 6 Line#C Router Side 6
+ 7 Line#D Network Side 7
+ 8 Line#D Router Side 8
+
+3.2. Objectives of this MIB Module
+
+ There are numerous things that could be included in a MIB for DS3/E3
+ signals: the management of multiplexors, CSUs, DSUs, and the like.
+ The intent of this document is to facilitate the common management of
+ all devices with DS3/E3 interfaces. As such, a design decision was
+ made up front to very closely align the MIB with the set of objects
+ that can generally be read from DS3/E3 devices that are currently
+ deployed.
+
+3.3. DS3/E3 Terminology
+
+ The terminology used in this document to describe error conditions on
+ a DS3 interface as monitored by a DS3 device are based on the
+ definitions from the ANSI T1M1.3/92-005R1 draft standard [12]. If
+ the definition in this document does not match the definition in the
+ ANSI T1M1.3/92-005R1 draft document, the implementer should follow
+ the definition described in this document.
+
+3.3.1. Error Events
+
+ Bipolar Violation (BPV) Error Event
+ A bipolar violation error event, for B3ZS(HDB3)-coded
+ signals, is the occurrence of a pulse of the same polarity
+ as the previous pulse without being part of the zero
+ substitution code, B3ZS(HDB3). For B3ZS(HDB3)-coded
+ signals, a bipolar violation error event may also include
+ other error patterns such as: three(four) or more
+ consecutive zeros and incorrect polarity.
+
+ Excessive Zeros (EXZ) Error Event
+ An EXZ is the occurrence of any zero string length equal
+ to or greater than 3 for B3ZS, or greater than 4 for HDB3.
+
+ Line Coding Violation (LCV) Error Event
+ This parameter is a count of both BPVs and EXZs
+ occurring over the accumulation period. An EXZ
+
+
+
+Trunk MIB Working Group [Page 7]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ increments the LCV by one regardless of the length
+ of the zero string.
+
+ P-bit Coding Violation (PCV) Error Event
+ For all DS3 applications, a coding violation error
+ event is a P-bit
+ Parity Error event. A P-bit Parity Error event is the
+ occurrence of a received P-bit code on the DS3 M-frame
+ that is not identical to the corresponding locally-
+ calculated code.
+
+ C-bit Coding Violation (CCV) Error Event
+ For C-bit Parity and SYNTRAN DS3 applications, this is
+ the count of coding violations reported via the C-bits.
+ For C-bit Parity, it is a count of CP-bit parity errors
+ occurring in the accumulation interval. For SYNTRAN, it
+ is a count of CRC-9 errors occurring in the accumulation
+ interval.
+
+3.3.2. Performance Parameters
+
+ All performance parameters are accumulated in fifteen minute
+ intervals and up to 96 intervals (24 hours worth) are kept by an
+ agent. Fewer than 96 intervals of data will be available if the
+ agent has been restarted within the last 24 hours. In addition,
+ there is a rolling 24-hour total of each performance parameter.
+
+ There is no requirement for an agent to ensure fixed relationship
+ between the start of a fifteen minute interval and any wall clock;
+ however some agents may align the fifteen minute intervals with
+ quarter hours.
+
+ Line Errored Seconds (LES)
+ A Line Errored Second is a second in
+ which one or more CVs occurred OR one or more LOS defects.
+
+ P-bit Errored Seconds (PES)
+ An PES is a second with one or more PCVs OR
+ one or more Out of Frame defects OR a detected incoming AIS.
+ This gauge is not incremented when UASs are counted.
+
+ P-bit Severely Errored Seconds (PSES)
+ A PSES is a second with 44 or more PCVs OR
+ one or more Out of Frame defects OR a detected incoming AIS.
+ This gauge is not incremented when UASs are counted.
+
+ C-bit Errored Seconds (CES)
+ An CES is a second with one or more CCVs OR
+
+
+
+Trunk MIB Working Group [Page 8]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ one or more Out of Frame defects OR a detected incoming AIS.
+ This count is only for the SYNTRAN and C-bit Parity DS3
+ applications. This gauge is not incremented when UASs are
+ counted.
+
+ C-bit Severely Errored Seconds (CSES)
+ A CSES is a second with 44 or more CCVs OR
+ one or more Out of Frame defects OR a detected incoming AIS.
+ This count is only for the SYNTRAN and C-bit Parity DS3
+ applications. This gauge is not incremented when UASs
+ are counted.
+
+ Severely Errored Framing Seconds (SEFS)
+ A SEFS is a second with one or more Out of Frame defects
+ OR a detected incoming AIS.
+
+ Unavailable Seconds (UAS)
+ UAS are calculated by counting the number of seconds that
+ the interface is unavailable. The DS3 interface is said
+ to be unavailable from the onset of 10 contiguous PSESs, or
+ the onset of the condition leading to a failure (see Failure
+ States). If the condition leading to the failure was
+ immediately preceded by one or more contiguous PSESs, then
+ the DS3 interface unavailability starts from the onset of
+ these PSESs. Once unavailable, and if no failure is
+ present, the DS3 interface becomes available at the onset
+ of 10 contiguous seconds with no PSESs. Once unavailable,
+ and if a failure is present, the DS3 interface becomes
+ available at the onset of 10 contiguous seconds with no
+ PSESs, if the failure clearing time is less than
+ or equal to 10 seconds. If the failure clearing time is
+ more than 10 seconds, the DS3 interface becomes available
+ at the onset of 10 contiguous seconds with no PSESs, or
+ the onset period leading to the successful clearing
+ condition, whichever occurs later. With respect to the
+ DS3 error counts, all counters are incremented
+ while the DS3 interface is deemed available. While the
+ interface is deemed unavailable, the only count that is
+ incremented is UASs.
+
+ A special case exists when the 10 or more second period
+ crosses the 900 second statistics window boundary, as the
+ foregoing description implies that the PSES and UAS
+ counters must be adjusted when the Unavailable Signal
+ State is entered. Clearly, successive GETs of the
+ affected dsx3IntervalPSESs and dsx3IntervalUASs objects
+ will return differing values if the first GET occurs
+ during the first few seconds of the window. This is
+
+
+
+Trunk MIB Working Group [Page 9]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ viewed as an unavoidable side-effect of selecting the
+ presently defined managed objects as a basis for this
+ memo.
+
+3.3.3. Performance Defects
+
+ Failure States:
+ The Remote Alarm Indication (RAI) failure, in SYNTRAN
+ applications, is declared after detecting
+ the Yellow Alarm Signal on the alarm channel. See ANSI
+ T1.107a-1990 [10]. The Remote Alarm Indication failure,
+ in C-bit Parity DS3 applications, is declared
+ as soon as the preqsence of either one or two alarm signals
+ are detected on then Far End Alarm Channel. See [10].
+ The Remote Alarm Indication failure may also be declared
+ after detecting the far-end SEF/AIS defect (aka yellow).
+ The Remote Alarm Indication failure is cleared as soon as
+ the presence of the any of the above alarms are removed.
+
+ Also, the incoming failure state is declared when a defect
+ persists for at least 2-10 seconds. The defects are
+ the following: Loss of Signal (LOS), an Out of Frame (OOF)
+ or an incoming Alarm Indication Signal (AIS).
+ The Failure State is cleared when the defect is absent
+ for less than or equal to 20 seconds.
+
+ Far End SEF/AIS defect (aka yellow)
+ A Far End SEF/AIS defect is the occurrence of the two X-bits
+ in a M-frame set to zero. The Far End SEF/AIS defect is
+ terminated when the two X-bits in a M-frame are set to
+ one.
+
+ Out of Frame (OOF) defect
+ A DS3 OOF defect is detected when any three or more errors
+ in sixteen or fewer consecutive F-bits occur within a DS3
+ M-frame. An OOF defect may also be called a Severely
+ Errored Frame (SEF) defect. An OOF defect is cleared when
+ reframe occurs. A DS3 Loss of Frame (LOF) failure is
+ declared when the DS3 OOF defect is consistent for 2 to 10
+ seconds. The DS3 OOF defect ends when reframe occurs.
+ The DS3 LOF failure is cleared when the DS3 OOF
+ defect is absent for 10 to 20 seconds.
+
+ An E3 OOF defect is detected when four consecutive frame
+ alignment signals have been incorrectly received in there
+ predicted positions in an E3 signal. E3 frame alignment
+ occurs when the presence of three consecutive frame
+ alignment signals have been detected.
+
+
+
+Trunk MIB Working Group [Page 10]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ Loss of Signal (LOS) defect
+ The DS3 LOS defect is declared upon observing 175 +/- 75
+ contiguous pulse positions with no pulses of either
+ positive or negative polarity.
+ The DS3 LOS defect is terminated upon observing an average
+ pulse density of at least 33% over a period of 175 +/- 75
+ contiguous pulse positions starting with the receipt of a
+ pulse.
+
+ Alarm Indication Signal (AIS) defect
+ The DS3 AIS is framed with "stuck stuffing." This implies
+ that it has a valid M-subframe alignments bits, M-frame
+ alignment bits, and P bits. The information bits are set
+ to a 1010... sequence, starting with a one (1) after each
+ M-subframe alignment bit, M-frame alignment bit, X bit, P
+ bit, and C bit. The C bits are all set to zero giving
+ what is called "stuck stuffing." The X bits are set to
+ one. The DS3 AIS defect is declared after DS3 AIS is
+ present in contiguous M-frames for a time equal to or
+ greater than T, where 0.2 ms <= T <= 100 ms.
+ The DS3 AIS defect is terminated after AIS is absent in
+ contiguous M-frames for a time equal to or greater than T.
+
+ The E3 binary content of the AIS is nominally a continuous
+ stream of ones. AIS detection and the application of
+ consequent actions, should be completed within a time
+ limit of 1 ms.
+
+3.3.4. Other Terms
+
+ Circuit Identifier
+ This is a character string specified by the circuit
+ vendor, and is useful when communicating with the vendor
+ during the troubleshooting process.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Trunk MIB Working Group [Page 11]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+4. Object Definitions
+
+ RFC1407-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ Gauge
+ FROM RFC1155-SMI
+ DisplayString, transmission
+ FROM RFC1213-MIB
+ OBJECT-TYPE
+ FROM RFC-1212;
+
+ -- This MIB module uses the extended OBJECT-TYPE macro
+ -- as defined in RFC 1212.
+
+ ds3 OBJECT IDENTIFIER ::= { transmission 30 }
+
+
+ -- The DS3/E3 Near End Group
+
+ -- Implementation of this group is mandatory for all
+ -- systems that attach to a DS3/E3 Interface.
+
+ -- The DS3/E3 Near End Group consists of four tables:
+ -- DS3/E3 Configuration
+ -- DS3/E3 Current
+ -- DS3/E3 Interval
+ -- DS3/E3 Total
+
+ -- the DS3/E3 Configuration
+
+ dsx3ConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3ConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3/E3 Configuration table."
+ ::= { ds3 5 }
+
+ dsx3ConfigEntry OBJECT-TYPE
+ SYNTAX Dsx3ConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3/E3 Configuration table."
+ INDEX { dsx3LineIndex }
+ ::= { dsx3ConfigTable 1 }
+
+
+
+
+Trunk MIB Working Group [Page 12]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ Dsx3ConfigEntry ::=
+ SEQUENCE {
+ dsx3LineIndex
+ INTEGER,
+ dsx3IfIndex
+ INTEGER,
+ dsx3TimeElapsed
+ INTEGER,
+ dsx3ValidIntervals
+ INTEGER,
+ dsx3LineType
+ INTEGER,
+ dsx3LineCoding
+ INTEGER,
+ dsx3SendCode
+ INTEGER,
+ dsx3CircuitIdentifier
+ DisplayString,
+ dsx3LoopbackConfig
+ INTEGER,
+ dsx3LineStatus
+ INTEGER,
+ dsx3TransmitClockSource
+ INTEGER
+ }
+
+ dsx3LineIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object is the identifier of a DS3/E3
+ Interface on a managed device. If there is an
+ ifEntry that is directly associated with this
+ and only this DS3/E3 interface, it should have
+ the same value as ifIndex. Otherwise, number
+ the dsx3LineIndices with an unique identifier
+ following the rules of choosing a number that
+ is greater than ifNumber and numbering the
+ inside interfaces (e.g., equipment side) with
+ even numbers and outside interfaces (e.g,
+ network side) with odd numbers."
+ ::= { dsx3ConfigEntry 1 }
+
+ dsx3IfIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+
+
+
+Trunk MIB Working Group [Page 13]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ DESCRIPTION
+ "This value for this object is equal to the
+ value of ifIndex from the Interfaces table of
+ MIB II (RFC 1213)."
+ ::= { dsx3ConfigEntry 2 }
+
+ dsx3TimeElapsed OBJECT-TYPE
+ SYNTAX INTEGER (0..899)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of seconds that have elapsed since
+ the beginning of the near end current error-
+ measurement period."
+ ::= { dsx3ConfigEntry 3 }
+
+ dsx3ValidIntervals OBJECT-TYPE
+ SYNTAX INTEGER (0..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of previous near end intervals for
+ which valid data was collected. The value will be
+ 96 unless the interface was brought online within
+ the last 24 hours, in which case the value will be
+ the number of complete 15 minute near end
+ intervals since the interface has been online."
+ ::= { dsx3ConfigEntry 4 }
+
+ dsx3LineType OBJECT-TYPE
+ SYNTAX INTEGER {
+ dsx3other(1),
+ dsx3M23(2),
+ dsx3SYNTRAN(3),
+ dsx3CbitParity(4),
+ dsx3ClearChannel(5),
+ e3other(6),
+ e3Framed(7),
+ e3Plcp(8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable indicates the variety of DS3 C-bit
+ or E3 application
+ implementing this interface. The type of
+ interface affects the interpretation of the
+ usage and error statistics.
+
+
+
+Trunk MIB Working Group [Page 14]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ The rate of DS3 is 44.736 Mbps and E3 is
+ 34.368 Mbps.
+ The dsx3ClearChannel value means that the C-bits
+ are not used except for sending/receiving
+ AIS.
+
+ The values, in sequence, describe:
+
+ TITLE: SPECIFICATION:
+ dsx3M23 ANSI T1.107-1988
+ dsx3SYNTRAN ANSI T1.107-1988
+ dsx3CbitParity ANSI T1.107a-1989
+ dsx3ClearChannel ANSI T1.102-1987
+ e3Framed CCITT G.751
+ e3Plcp ETSI T/NA(91)18."
+ ::= { dsx3ConfigEntry 5 }
+
+ dsx3LineCoding OBJECT-TYPE
+ SYNTAX INTEGER {
+ dsx3Other(1),
+ dsx3B3ZS(2),
+ e3HDB3(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable describes the variety of Zero Code
+ Suppression used on this interface, which in turn
+ affects a number of its characteristics.
+
+ dsx3B3ZS and e3HDB3 refer to the use of specified
+ patterns of normal bits and bipolar violations
+ which are used to replace sequences of zero bits
+ of a specified length."
+ ::= { dsx3ConfigEntry 6 }
+
+ dsx3SendCode OBJECT-TYPE
+ SYNTAX INTEGER {
+ dsx3SendNoCode(1),
+ dsx3SendLineCode(2),
+ dsx3SendPayloadCode(3),
+ dsx3SendResetCode(4),
+ dsx3SendDS1LoopCode(5),
+ dsx3SendTestPattern(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+
+
+
+Trunk MIB Working Group [Page 15]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ "This variable indicates what type of code is
+ being sent across the DS3/E3 interface by the
+ device. (These are optional for E3 interfaces.)
+ The values mean:
+
+ dsx3SendNoCode
+ sending looped or normal data
+
+ dsx3SendLineCode
+ sending a request for a line loopback
+
+ dsx3SendPayloadCode
+ sending a request for a payload loopback
+ (i.e., all DS1/E1s in a DS3/E3 frame)
+
+ dsx3SendResetCode
+ sending a loopback deactivation request
+
+ dsx3SendDS1LoopCode
+ requesting to loopback a particular DS1/E1
+ within a DS3/E3 frame
+
+ dsx3SendTestPattern
+ sending a test pattern."
+ ::= { dsx3ConfigEntry 7 }
+
+ dsx3CircuitIdentifier OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable contains the transmission vendor's
+ circuit identifier, for the purpose of
+ facilitating troubleshooting."
+ ::= { dsx3ConfigEntry 8 }
+
+ dsx3LoopbackConfig OBJECT-TYPE
+ SYNTAX INTEGER {
+ dsx3NoLoop(1),
+ dsx3PayloadLoop(2),
+ dsx3LineLoop(3),
+ dsx3OtherLoop(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable represents the loopback configuration
+ of the DS3/E3 interface.
+
+
+
+Trunk MIB Working Group [Page 16]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ The values mean:
+
+ dsx3NoLoop
+ Not in the loopback state. A device that is
+ not capable of performing a loopback on
+ the interface shall always return this as
+ it's value.
+
+ dsx3PayloadLoop
+ The received signal at this interface is looped
+ through the device.
+ Typically the received signal
+ is looped back for retransmission after it has
+ passed through the device's framing function.
+
+ dsx3LineLoop
+ The received signal at this interface does not
+ go through the device (minimum penetration) but
+ is looped back out.
+
+ dsx3OtherLoop
+ Loopbacks that are not defined here."
+ ::= { dsx3ConfigEntry 9 }
+
+ dsx3LineStatus OBJECT-TYPE
+ SYNTAX INTEGER (1..1023)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable indicates the
+ Line Status of the interface.
+ It contains loopback state information
+ and failure state information.
+ The dsx3LineStatus is a bit map represented
+ as a sum, therefore,
+ it can represent multiple failures
+ and a loopback (see dsx3LoopbackConfig object
+ for the type of loopback)
+ simultaneously.
+ The dsx3NoAlarm should be set if and only if
+ no other flag is set.
+
+ The various bit positions are:
+ 1 dsx3NoAlarm No alarm present
+ 2 dsx3RcvRAIFailure Receiving Yellow/Remote
+ Alarm Indication
+ 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote
+ Alarm Indication
+
+
+
+Trunk MIB Working Group [Page 17]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ 8 dsx3RcvAIS Receiving AIS failure state
+ 16 dsx3XmitAIS Transmitting AIS
+ 32 dsx3LOF Receiving LOF failure state
+ 64 dsx3LOS Receiving LOS failure state
+ 128 dsx3LoopbackState Looping the received signal
+ 256 dsx3RcvTestCode Receiving a Test Pattern
+ 512 dsx3OtherFailure any line status not defined
+ here"
+ ::= { dsx3ConfigEntry 10 }
+
+ dsx3TransmitClockSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ loopTiming(1),
+ localTiming(2),
+ throughTiming(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The source of Transmit Clock.
+ is derived from the recovered receive clock of
+ another DS3 interface."
+ ::= { dsx3ConfigEntry 11 }
+
+
+ -- the DS3/E3 Current
+
+ -- The DS3/E3 current table contains various statistics being
+ -- collected for the current 15 minute interval.
+
+ dsx3CurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3CurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3/E3 Current table."
+ ::= { ds3 6 }
+
+ dsx3CurrentEntry OBJECT-TYPE
+ SYNTAX Dsx3CurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3/E3 Current table."
+ INDEX { dsx3CurrentIndex }
+ ::= { dsx3CurrentTable 1 }
+
+
+
+
+
+Trunk MIB Working Group [Page 18]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ Dsx3CurrentEntry ::=
+ SEQUENCE {
+ dsx3CurrentIndex
+ INTEGER,
+ dsx3CurrentPESs
+ Gauge,
+ dsx3CurrentPSESs
+ Gauge,
+ dsx3CurrentSEFSs
+ Gauge,
+ dsx3CurrentUASs
+ Gauge,
+ dsx3CurrentLCVs
+ Gauge,
+ dsx3CurrentPCVs
+ Gauge,
+ dsx3CurrentLESs
+ Gauge,
+ dsx3CurrentCCVs
+ Gauge,
+ dsx3CurrentCESs
+ Gauge,
+ dsx3CurrentCSESs
+ Gauge
+ }
+
+ dsx3CurrentIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3/E3 interface to which this entry is
+ applicable. The interface identified by a
+ particular value of this index is the same
+ interface as identified by the same value an
+ dsx3LineIndex object instance."
+ ::= { dsx3CurrentEntry 1 }
+
+ dsx3CurrentPESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Errored Seconds, encountered by a DS3 interface in
+ the current 15 minute interval."
+ ::= { dsx3CurrentEntry 2 }
+
+
+
+Trunk MIB Working Group [Page 19]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3CurrentPSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Severely Errored Seconds, encountered by a DS3
+ interface in the current 15 minute interval."
+ ::= { dsx3CurrentEntry 3 }
+
+ dsx3CurrentSEFSs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Severely Errored Framing Seconds, encountered by a
+ DS3/E3 interface in the current 15 minute
+ interval."
+ ::= { dsx3CurrentEntry 4 }
+
+ dsx3CurrentUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, encountered by a DS3
+ interface in the current 15 minute interval."
+ ::= { dsx3CurrentEntry 5 }
+
+ dsx3CurrentLCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of Line
+ Coding Violations encountered by a DS3/E3
+ interface in the current 15 minute interval."
+ ::= { dsx3CurrentEntry 6 }
+
+ dsx3CurrentPCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Coding Violations, encountered by a DS3 interface
+
+
+
+Trunk MIB Working Group [Page 20]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ in the current 15 minute interval."
+ ::= { dsx3CurrentEntry 7 }
+
+ dsx3CurrentLESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Line Errored Seconds encountered by
+ a DS3/E3 interface in the current 15 minute
+ interval."
+ ::= { dsx3CurrentEntry 8 }
+
+ dsx3CurrentCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Coding Violations encountered
+ by a DS3 interface in the current 15 minute
+ interval."
+ ::= { dsx3CurrentEntry 9 }
+
+ dsx3CurrentCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Errored Seconds encountered
+ by a DS3 interface in the current 15 minute
+ interval."
+ ::= { dsx3CurrentEntry 10 }
+
+ dsx3CurrentCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Severely Errored Seconds
+ encountered by a DS3 interface in the current 15
+ minute interval."
+ ::= { dsx3CurrentEntry 11 }
+
+
+ -- the DS3/E3 Interval
+
+ -- The DS3/E3 Interval Table contains various statistics
+ -- collected by each DS3/E3 Interface over the previous 24
+
+
+
+Trunk MIB Working Group [Page 21]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ -- hours of operation. The past 24 hours are broken into 96
+ -- completed 15 minute intervals.
+
+ dsx3IntervalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3IntervalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3/E3 Interval table."
+ ::= { ds3 7 }
+
+ dsx3IntervalEntry OBJECT-TYPE
+ SYNTAX Dsx3IntervalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3/E3 Interval table."
+ INDEX { dsx3IntervalIndex, dsx3IntervalNumber }
+ ::= { dsx3IntervalTable 1 }
+
+ Dsx3IntervalEntry ::=
+ SEQUENCE {
+ dsx3IntervalIndex
+ INTEGER,
+ dsx3IntervalNumber
+ INTEGER,
+ dsx3IntervalPESs
+ Gauge,
+ dsx3IntervalPSESs
+ Gauge,
+ dsx3IntervalSEFSs
+ Gauge,
+ dsx3IntervalUASs
+ Gauge,
+ dsx3IntervalLCVs
+ Gauge,
+ dsx3IntervalPCVs
+ Gauge,
+ dsx3IntervalLESs
+ Gauge,
+ dsx3IntervalCCVs
+ Gauge,
+ dsx3IntervalCESs
+ Gauge,
+ dsx3IntervalCSESs
+ Gauge
+ }
+
+
+
+
+Trunk MIB Working Group [Page 22]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3IntervalIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3/E3 interface to which this entry is
+ applicable. The interface identified by a
+ particular value of this index is the same
+ interface as identified by the same value an
+ dsx3LineIndex object instance."
+ ::= { dsx3IntervalEntry 1 }
+
+ dsx3IntervalNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number between 1 and 96, where 1 is the most
+ recently completed 15 minute interval and 96 is
+ the least recently completed 15 minutes interval
+ (assuming that all 96 intervals are valid)."
+ ::= { dsx3IntervalEntry 2 }
+
+ dsx3IntervalPESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Errored Seconds, encountered by a DS3 interface in
+ one of the previous 96, individual 15 minute,
+ intervals."
+ ::= { dsx3IntervalEntry 3 }
+
+ dsx3IntervalPSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Severely Errored Seconds, encountered by a DS3
+ interface in one of the previous 96, individual 15
+ minute, intervals."
+ ::= { dsx3IntervalEntry 4 }
+
+ dsx3IntervalSEFSs OBJECT-TYPE
+ SYNTAX Gauge
+
+
+
+Trunk MIB Working Group [Page 23]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Severely Errored Framing Seconds, encountered by a
+ DS3/E3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3IntervalEntry 5 }
+
+ dsx3IntervalUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, encountered by a DS3
+ interface in one of the previous 96, individual 15
+ minute, intervals."
+ ::= { dsx3IntervalEntry 6 }
+
+ dsx3IntervalLCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of Line
+ Coding Violations encountered by a DS3/E3
+ interface in one of the previous 96, individual 15
+ minute, intervals."
+ ::= { dsx3IntervalEntry 7 }
+
+ dsx3IntervalPCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Coding Violations, encountered by a DS3 interface
+ in one of the previous 96, individual 15 minute,
+ intervals."
+ ::= { dsx3IntervalEntry 8 }
+
+ dsx3IntervalLESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Line Errored Seconds (BPVs or
+
+
+
+Trunk MIB Working Group [Page 24]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ illegal zero sequences) encountered by a DS3/E3
+ interface in one of the previous 96, individual
+ 15 minute, intervals."
+ ::= { dsx3IntervalEntry 9 }
+
+ dsx3IntervalCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Coding Violations encountered
+ by a DS3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3IntervalEntry 10 }
+
+ dsx3IntervalCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Errored Seconds encountered
+ by a DS3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3IntervalEntry 11 }
+
+ dsx3IntervalCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Severely Errored Seconds
+ encountered by a DS3 interface in one of the
+ previous 96, individual 15 minute, intervals."
+ ::= { dsx3IntervalEntry 12 }
+
+
+ -- the DS3/E3 Total
+
+ -- The DS3/E3 Total Table contains the cumulative sum of the
+ -- various statistics for the 24 hour period preceding the
+ -- current interval.
+
+ dsx3TotalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3TotalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3/E3 Total table. 24 hour interval."
+
+
+
+Trunk MIB Working Group [Page 25]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ::= { ds3 8 }
+
+ dsx3TotalEntry OBJECT-TYPE
+ SYNTAX Dsx3TotalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3/E3 Total table."
+ INDEX { dsx3TotalIndex }
+ ::= { dsx3TotalTable 1 }
+
+ Dsx3TotalEntry ::=
+ SEQUENCE {
+ dsx3TotalIndex
+ INTEGER,
+ dsx3TotalPESs
+ Gauge,
+ dsx3TotalPSESs
+ Gauge,
+ dsx3TotalSEFSs
+ Gauge,
+ dsx3TotalUASs
+ Gauge,
+ dsx3TotalLCVs
+ Gauge,
+ dsx3TotalPCVs
+ Gauge,
+ dsx3TotalLESs
+ Gauge,
+ dsx3TotalCCVs
+ Gauge,
+ dsx3TotalCESs
+ Gauge,
+ dsx3TotalCSESs
+ Gauge
+ }
+
+ dsx3TotalIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3/E3 interface to which this entry is
+ applicable. The interface identified by a
+ particular value of this index is the same
+ interface as identified by the same value an
+ dsx3LineIndex object instance."
+
+
+
+Trunk MIB Working Group [Page 26]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ::= { dsx3TotalEntry 1 }
+
+ dsx3TotalPESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Errored Seconds, encountered by a DS3 interface in
+ the previous 24 hour interval"
+ ::= { dsx3TotalEntry 2 }
+
+ dsx3TotalPSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Severely Errored Seconds, encountered by a DS3
+ interface in the previous 24 hour interval."
+ ::= { dsx3TotalEntry 3 }
+
+ dsx3TotalSEFSs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Severely Errored Framing Seconds, encountered by a
+ DS3/E3 interface in the previous 24 hour
+ interval."
+ ::= { dsx3TotalEntry 4 }
+
+ dsx3TotalUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, encountered by a DS3
+ interface in the previous 24 hour interval."
+ ::= { dsx3TotalEntry 5 }
+
+ dsx3TotalLCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+
+
+
+Trunk MIB Working Group [Page 27]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ "The counter associated with the number of Line
+ Coding Violations encountered by a DS3/E3
+ interface in the previous 24 hour interval."
+ ::= { dsx3TotalEntry 6 }
+
+ dsx3TotalPCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of P-bit
+ Coding Violations, encountered by a DS3 interface
+ in the previous 24 hour interval."
+ ::= { dsx3TotalEntry 7 }
+
+ dsx3TotalLESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Line Errored Seconds (BPVs or
+ illegal zero sequences) encountered by a DS3/E3
+ interface in the previous 24 hour interval."
+ ::= { dsx3TotalEntry 8 }
+
+ dsx3TotalCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Coding Violations encountered
+ by a DS3 interface in the previous 24 hour
+ interval."
+ ::= { dsx3TotalEntry 9 }
+
+ dsx3TotalCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Errored Seconds encountered
+ by a DS3 interface in the previous 24 hour
+ interval."
+ ::= { dsx3TotalEntry 10 }
+
+ dsx3TotalCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+
+
+
+Trunk MIB Working Group [Page 28]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "The number of C-bit Severely Errored Seconds
+ encountered by a DS3 interface in the previous 24
+ hour interval."
+ ::= { dsx3TotalEntry 11 }
+
+
+ -- The DS3 Far End Group
+
+ -- Implementation of this group is optional for all systems
+ -- that attach to a DS3 Interface.
+ -- However, only C-bit Parity and SYNTRAN DS3 applications
+ -- have the capability (option) of providing this information.
+
+ -- The DS3 Far End Group consists of four tables:
+ -- DS3 Far End Configuration
+ -- DS3 Far End Current
+ -- DS3 Far End Interval
+ -- DS3 Far End Total
+
+
+ -- The DS3 Far End Configuration Table contains
+ -- configuration information
+ -- reported in the C-bits from the remote end.
+
+ dsx3FarEndConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3 Far End Configuration table."
+ ::= { ds3 9 }
+
+ dsx3FarEndConfigEntry OBJECT-TYPE
+ SYNTAX Dsx3FarEndConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3 Far End Configuration table."
+ INDEX { dsx3FarEndLineIndex }
+ ::= { dsx3FarEndConfigTable 1 }
+
+ Dsx3FarEndConfigEntry ::=
+ SEQUENCE {
+ dsx3FarEndLineIndex
+ INTEGER,
+ dsx3FarEndEquipCode
+
+
+
+Trunk MIB Working Group [Page 29]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ DisplayString,
+ dsx3FarEndLocationIDCode
+ DisplayString,
+ dsx3FarEndFrameIDCode
+ DisplayString,
+ dsx3FarEndUnitCode
+ DisplayString,
+ dsx3FarEndFacilityIDCode
+ DisplayString
+ }
+
+ dsx3FarEndLineIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3 interface
+ to which this entry is applicable. The
+ interface identified by a particular value of
+ this index is the same interface as identified
+ by the same value an dsx3LineIndex object
+ instance."
+ ::= { dsx3FarEndConfigEntry 1 }
+
+ dsx3FarEndEquipCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..10))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Far End Equipment Identification code
+ that describes the specific piece of equipment.
+ It is sent within the Path
+ Identification Message."
+ ::= { dsx3FarEndConfigEntry 2 }
+
+ dsx3FarEndLocationIDCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..11))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Far End Location Identification code
+ that describes the specific location of the
+ equipment.
+ It is sent within the Path
+ Identification Message."
+ ::= { dsx3FarEndConfigEntry 3 }
+
+
+
+
+Trunk MIB Working Group [Page 30]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3FarEndFrameIDCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..10))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Far End Frame Identification code
+ that identifies where the equipment is located
+ within a building at a given location.
+ It is sent within the Path
+ Identification Message."
+ ::= { dsx3FarEndConfigEntry 4 }
+
+ dsx3FarEndUnitCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..6))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This is the Far End code
+ that identifies the equipment location within a bay.
+ It is sent within the Path
+ Identification Message."
+ ::= { dsx3FarEndConfigEntry 5 }
+
+ dsx3FarEndFacilityIDCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..38))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This code identifies a specific Far End DS3 path.
+ It is sent within the Path
+ Identification Message."
+ ::= { dsx3FarEndConfigEntry 6 }
+
+
+ -- The DS3 Far End Current
+
+ -- The DS3 Far End Current table contains various statistics
+ -- being collected for the current 15 minute interval.
+ -- The statistics are collected from the far end block error
+ -- code within the C-bits.
+
+ dsx3FarEndCurrentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3 Far End Current table."
+ ::= { ds3 10 }
+
+
+
+Trunk MIB Working Group [Page 31]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3FarEndCurrentEntry OBJECT-TYPE
+ SYNTAX Dsx3FarEndCurrentEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3 Far End Current table."
+ INDEX { dsx3FarEndCurrentIndex }
+ ::= { dsx3FarEndCurrentTable 1 }
+
+ Dsx3FarEndCurrentEntry ::=
+ SEQUENCE {
+ dsx3FarEndCurrentIndex
+ INTEGER,
+ dsx3FarEndTimeElapsed
+ INTEGER,
+ dsx3FarEndValidIntervals
+ INTEGER,
+ dsx3FarEndCurrentCESs
+ Gauge,
+ dsx3FarEndCurrentCSESs
+ Gauge,
+ dsx3FarEndCurrentCCVs
+ Gauge,
+ dsx3FarEndCurrentUASs
+ Gauge
+ }
+
+ dsx3FarEndCurrentIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3 interface
+ to which this entry is applicable. The interface
+ identified by a particular value of this index is
+ the same interface as identified by the same value
+ an dsx3LineIndex object instance."
+ ::= { dsx3FarEndCurrentEntry 1 }
+
+ dsx3FarEndTimeElapsed OBJECT-TYPE
+ SYNTAX INTEGER (0..899)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of seconds that have elapsed since the
+ beginning of the far end current error-measurement
+ period."
+
+
+
+Trunk MIB Working Group [Page 32]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ::= { dsx3FarEndCurrentEntry 2 }
+
+ dsx3FarEndValidIntervals OBJECT-TYPE
+ SYNTAX INTEGER (0..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of previous far end intervals for
+ which valid data was collected. The value will be
+ 96 unless the interface was brought online within
+ the last 24 hours, in which case the value will be
+ the number of complete 15 minute far end intervals
+ since the interface has been online."
+ ::= { dsx3FarEndCurrentEntry 3 }
+
+ dsx3FarEndCurrentCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of Far
+ Far End C-bit Errored Seconds encountered by a DS3
+ interface in the current 15 minute interval."
+ ::= { dsx3FarEndCurrentEntry 4 }
+
+ dsx3FarEndCurrentCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Severely Errored Seconds
+ encountered by a DS3 interface in the current 15
+ minute interval."
+ ::= { dsx3FarEndCurrentEntry 5 }
+
+ dsx3FarEndCurrentCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Coding Violations reported via
+ the far end block error count
+ encountered by a
+ DS3 interface in the current 15 minute interval."
+ ::= { dsx3FarEndCurrentEntry 6 }
+
+
+
+
+Trunk MIB Working Group [Page 33]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3FarEndCurrentUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End unavailable seconds
+ encountered by a
+ DS3 interface in the current 15 minute interval."
+ ::= { dsx3FarEndCurrentEntry 7 }
+
+
+ -- The DS3 Far End Interval
+
+ -- The DS3 Far End Interval Table contains various statistics
+ -- collected by each DS3 interface over the previous 24
+ -- hours of operation. The past 24 hours are broken into 96
+ -- completed 15 minute intervals.
+
+ dsx3FarEndIntervalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3 Far End Interval table."
+ ::= { ds3 11 }
+
+ dsx3FarEndIntervalEntry OBJECT-TYPE
+ SYNTAX Dsx3FarEndIntervalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3 Far
+ End Interval table."
+ INDEX { dsx3FarEndIntervalIndex,
+ dsx3FarEndIntervalNumber }
+ ::= { dsx3FarEndIntervalTable 1 }
+
+ Dsx3FarEndIntervalEntry ::=
+ SEQUENCE {
+ dsx3FarEndIntervalIndex
+ INTEGER,
+ dsx3FarEndIntervalNumber
+ INTEGER,
+ dsx3FarEndIntervalCESs
+ Gauge,
+ dsx3FarEndIntervalCSESs
+ Gauge,
+
+
+
+Trunk MIB Working Group [Page 34]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3FarEndIntervalCCVs
+ Gauge,
+ dsx3FarEndIntervalUASs
+ Gauge
+ }
+
+ dsx3FarEndIntervalIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3 interface
+ to which this entry is applicable. The
+ interface identified by a particular value of
+ this index is the same interface as identified
+ by the same value an dsx3LineIndex object
+ instance."
+ ::= { dsx3FarEndIntervalEntry 1 }
+
+ dsx3FarEndIntervalNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..96)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A number between 1 and 96, where 1 is the most
+ recently completed 15 minute interval and 96 is
+ the least recently completed 15 minutes
+ interval (assuming that all 96 intervals are
+ valid)."
+ ::= { dsx3FarEndIntervalEntry 2 }
+
+ dsx3FarEndIntervalCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Errored Seconds encountered
+ by a DS3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3FarEndIntervalEntry 3 }
+
+ dsx3FarEndIntervalCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+
+
+
+Trunk MIB Working Group [Page 35]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ "The counter associated with the number of
+ Far End C-bit Severely Errored Seconds
+ encountered by a DS3 interface in one of the
+ previous 96, individual 15 minute, intervals."
+ ::= { dsx3FarEndIntervalEntry 4 }
+
+ dsx3FarEndIntervalCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Coding Violations reported via
+ the far end block error count
+ encountered by a
+ DS3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3FarEndIntervalEntry 5 }
+
+ dsx3FarEndIntervalUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End unavailable seconds
+ encountered by a
+ DS3 interface in one of the previous 96,
+ individual 15 minute, intervals."
+ ::= { dsx3FarEndIntervalEntry 6 }
+
+
+ -- The DS3 Far End Total
+
+ -- The DS3 Far End Total Table contains the cumulative sum
+ -- of the various statistics for the 24 hour period preceding
+ -- the current interval.
+
+ dsx3FarEndTotalTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3 Far End Total table. 24 hour interval."
+ ::= { ds3 12 }
+
+ dsx3FarEndTotalEntry OBJECT-TYPE
+ SYNTAX Dsx3FarEndTotalEntry
+
+
+
+Trunk MIB Working Group [Page 36]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3 Far End Total table."
+ INDEX { dsx3FarEndTotalIndex }
+ ::= { dsx3FarEndTotalTable 1 }
+
+ Dsx3FarEndTotalEntry ::=
+ SEQUENCE {
+ dsx3FarEndTotalIndex
+ INTEGER,
+ dsx3FarEndTotalCESs
+ Gauge,
+ dsx3FarEndTotalCSESs
+ Gauge,
+ dsx3FarEndTotalCCVs
+ Gauge,
+ dsx3FarEndTotalUASs
+ Gauge
+ }
+
+ dsx3FarEndTotalIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3 interface
+ to which this entry is applicable. The interface
+ identified by a particular value of this index is
+ the same interface as identified by the same value
+ an dsx3LineIndex object instance."
+ ::= { dsx3FarEndTotalEntry 1 }
+
+ dsx3FarEndTotalCESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of Far
+ End C-bit Errored Seconds encountered by a DS3
+ interface in the previous 24 hour interval."
+ ::= { dsx3FarEndTotalEntry 2 }
+
+ dsx3FarEndTotalCSESs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+
+
+
+Trunk MIB Working Group [Page 37]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Severely Errored Seconds
+ encountered by a DS3 interface in the previous 24
+ hour interval."
+ ::= { dsx3FarEndTotalEntry 3 }
+
+ dsx3FarEndTotalCCVs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End C-bit Coding Violations reported via the
+ far end block error count
+ encountered by a
+ DS3 interface in the previous 24 hour interval."
+ ::= { dsx3FarEndTotalEntry 4 }
+
+ dsx3FarEndTotalUASs OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The counter associated with the number of
+ Far End unavailable seconds
+ encountered by a
+ DS3 interface in the previous 24 hour interval."
+ ::= { dsx3FarEndTotalEntry 5 }
+
+
+ -- the DS3/E3 Fractional Group
+
+ -- Implementation of this group is optional. It is designed
+ -- for those systems dividing a DS3/E3 into channels
+ -- containing different data streams that are of local
+ -- interest.
+
+ -- The DS3/E3 fractional table identifies which DS3/E3
+ -- channels associated with a CSU are being used to
+ -- support a logical interface, i.e., an entry in the
+ -- interfaces table from the Internet-standard MIB.
+
+ -- For example, consider a DS3 device with 4 high speed links
+ -- carrying router traffic, a feed for voice, a feed for
+ -- video, and a synchronous channel for a non-routed
+ -- protocol.
+ -- We might describe the allocation of channels, in the
+
+
+
+Trunk MIB Working Group [Page 38]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ -- dsx3FracTable, as follows:
+
+ -- dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4
+ -- dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6
+ -- dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6
+ -- dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6
+ -- dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6
+ -- dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6
+ -- dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6
+ -- dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6
+ -- dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6
+ -- dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6
+ -- dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6
+ -- dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6
+ -- dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6
+ -- dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6
+
+ -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and
+ -- dsx3ClearChannel there are 28 legal channels, numbered 1
+ -- through 28.
+
+ -- For e3Framed there are 16 legal channels,
+ -- numbered 1 through 16. The channels (1..16) correspond
+ -- directly to the equivalently numbered time-slots.
+
+ dsx3FracTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Dsx3FracEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The DS3 Fractional table."
+ ::= { ds3 13 }
+
+ dsx3FracEntry OBJECT-TYPE
+ SYNTAX Dsx3FracEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry in the DS3 Fractional table."
+ INDEX { dsx3FracIndex, dsx3FracNumber }
+ ::= { dsx3FracTable 1 }
+
+ Dsx3FracEntry ::=
+ SEQUENCE {
+ dsx3FracIndex
+ INTEGER,
+ dsx3FracNumber
+ INTEGER,
+
+
+
+Trunk MIB Working Group [Page 39]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ dsx3FracIfIndex
+ INTEGER
+ }
+
+
+ dsx3FracIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..'7fffffff'h)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index value which uniquely identifies the
+ DS3 interface to which this entry is applicable
+ The interface identified by a particular
+ value of this index is the same interface as
+ identified by the same value an dsx3LineIndex
+ object instance."
+ ::= { dsx3FracEntry 1 }
+
+ dsx3FracNumber OBJECT-TYPE
+ SYNTAX INTEGER (1..31)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The channel number for this entry."
+ ::= { dsx3FracEntry 2 }
+
+ dsx3FracIfIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..'7fffffff'h)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An index value that uniquely identifies an
+ interface. The interface identified by a particular
+ value of this index is the same interface
+ as identified by the same value an ifIndex
+ object instance. If no interface is currently using
+ a channel, the value should be zero. If a
+ single interface occupies more than one time
+ slot, that ifIndex value will be found in multiple
+ time slots."
+ ::= { dsx3FracEntry 3 }
+
+
+
+ END
+
+
+
+
+
+
+Trunk MIB Working Group [Page 40]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+5. Acknowledgments
+
+This document was produced by the Trunk MIB Working Groups:
+
+ Tracy Cox Bellcore
+ Fred Baker Advanced Computer Communications
+ James Watt Newbridge
+ Bill Versteeg Versteeg Codeworks
+ Steve Buchko Newbridge
+ Greg Calmainis Newbridge
+ Kaj Tesink Bellcore
+ Al Bryenton Bell Northern Research
+ Tom Easterday CIC
+ John Labbe Merit Corporation
+ Chris Sullivan Gandalf Ltd
+ Grant Hall Gandalf Ltd
+ John Guerrero Digital Link
+ Rich Bradford BBN
+ Kurt Luoto Digital Link
+ Myron Hattig Kentrox
+ Ed Pring IBM
+ Larry Marks IBM
+ Kurt Hall Clear Communications Corp.
+ Jason Perreault Coral Network Corp.
+ Paul Farah T3plus
+ George Kajos Coral Network Corp.
+
+6. References
+
+ [1] Cerf, V., "IAB Recommendations for the Development of Internet
+ Network Management Standards", RFC 1052, NRI, April 1988.
+
+ [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
+ Group", RFC 1109, NRI, August 1989.
+
+ [3] Rose M., and K. McCloghrie, "Structure and Identification of
+ Management Information for TCP/IP-based internets", STD 16, RFC
+ 1155, Performance Systems International, Hughes LAN Systems, May
+ 1990.
+
+ [4] McCloghrie K., and M. Rose, "Management Information Base for
+ Network Management of TCP/IP-based internets", RFC 1156, Hughes
+ LAN Systems, Performance Systems International, May 1990.
+
+ [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
+ Network Management Protocol", STD 15, RFC 1157, SNMP Research,
+ Performance Systems International, Performance Systems
+ International, MIT Laboratory for Computer Science, May 1990.
+
+
+
+Trunk MIB Working Group [Page 41]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+ [6] McCloghrie K., and M. Rose, Editors, "Management Information Base
+ for Network Management of TCP/IP-based internets", STD 17, RFC
+ 1213, Performance Systems International, March 1991.
+
+ [7] Information processing systems - Open Systems Interconnection -
+ Specification of Abstract Syntax Notation One (ASN.1),
+ International Organization for Standardization, International
+ Standard 8824, December 1987.
+
+ [8] Information processing systems - Open Systems Interconnection -
+ Specification of Basic Encoding Rules for Abstract Notation One
+ (ASN.1), International Organization for Standardization,
+ International Standard 8825, December 1987.
+
+ [9] American National Standard for Telecommunications - Digital
+ Hierarchy - Electrical Interfaces, ANSI T1.102- 1987.
+
+ [10] American National Standard for Telecommunications - Digital
+ Hierarchy - Formats Specification, ANSI T1.107- 1988.
+
+ [10a] ANSI T1.107a-1990.
+
+ [11] American National Standard for Telecommunications - Carrier-to-
+ Customer Installation - DS3 Metallic Interface, ANSI T1.404-1989.
+
+ [12] American National Standard for Telecommunications -- Layer 1 In-
+ Service Digital Transmission Performance Monitoring T1M1/92-0xx,
+ T1M1.3/92-005R1, April 1992.
+
+ [13] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
+ STD 16, RFC 1212, Performance Systems International, Hughes LAN
+ Systems, March 1991.
+
+ [14] CCITT - Digital Multiplex Equipment Operating at the Third Order
+ Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264
+ Kbit/s and Using Positive Justification, G.751.
+
+ [15] European Telecommunications Standards Institute -- ETS "34M" --
+ Metropolitan Area Network Physical Convergence Layer Procedure
+ for 34.368 Megabits per Second, T/NA(91)18, May 1991.
+
+
+
+
+
+
+
+
+
+
+
+Trunk MIB Working Group [Page 42]
+
+RFC 1407 DS3/E3 MIB January 1993
+
+
+7. Security Considerations
+
+ Security issues are not discussed in this memo.
+
+8. Authors' Addresses
+
+ Tracy A. Cox
+ Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+
+ Phone: (908) 758-2107
+ EMail: tacox@mail.bellcore.com
+
+
+ Kaj Tesink
+ Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+
+ Phone: (908) 758-5254
+ EMail: kaj@cc.bellcore.com
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Trunk MIB Working Group [Page 43]
+ \ No newline at end of file