diff options
Diffstat (limited to 'doc/rfc/rfc1407.txt')
-rw-r--r-- | doc/rfc/rfc1407.txt | 2411 |
1 files changed, 2411 insertions, 0 deletions
diff --git a/doc/rfc/rfc1407.txt b/doc/rfc/rfc1407.txt new file mode 100644 index 0000000..d3165db --- /dev/null +++ b/doc/rfc/rfc1407.txt @@ -0,0 +1,2411 @@ + + + + + + +Network Working Group T. Cox +Request for Comments: 1407 K. Tesink +Obsoletes: 1233 Bell Communications Research + Editors + January 1993 + + + Definitions of Managed Objects + for the DS3/E3 Interface Type + +Status of this Memo + + This RFC specifies an IAB standards track protocol for the Internet + community, and requests discussion and suggestions for improvements. + Please refer to the current edition of the "IAB Official Protocol + Standards" for the standardization state and status of this protocol. + Distribution of this memo is unlimited. + +Abstract + + This memo defines an extension to the Management Information Base + (MIB) for use with network management protocols in TCP/IP-based + internets. In particular, it defines objects for managing DS3 and E3 + Interfaces. This document is a companion document with Definitions + of Managed Objects for the DS1 Interface Type. + + This document entirely replaces RFC 1233, which contains a + fundamental error: many objects are encoded as Counters that must be + encoded as INTEGERs or Gauges. The magnitude of the change required + is sufficient that virtually every object changed. Therefore, the + MIB documented in RFC 1233 should not be implemented. + +Table of Contents + + 1. The Network Management Framework ...................... 2 + 2. Objects ............................................... 2 + 2.1 Format of Definitions ................................ 3 + 2.2 Changes from RFC 1233 ................................ 3 + 3. Overview .............................................. 5 + 3.1 Binding between ifIndex and DS3/E3 Interfaces ........ 5 + 3.2 Objectives of this MIB Module ........................ 7 + 3.3 DS3/E3 Terminology ................................... 7 + 3.3.1 Error Events ....................................... 7 + 3.3.2 Performance Parameters ............................. 8 + 3.3.3 Performance Defects ................................ 10 + 3.3.4 Other Terms ........................................ 11 + 4. Object Definitions .................................... 12 + 4.1 The DS3/E3 Near End Group ............................ 12 + + + +Trunk MIB Working Group [Page 1] + +RFC 1407 DS3/E3 MIB January 1993 + + + 4.1.1 The DS3/E3 Configuration ........................... 12 + 4.1.2 The DS3/E3 Current ................................. 18 + 4.1.3 The DS3/E3 Interval ................................ 21 + 4.1.4 The DS3/E3 Total ................................... 25 + 4.2 The DS3 Far End Group ................................ 29 + 4.2.1 The DS3 Far End Configuration ...................... 29 + 4.2.2 The DS3 Far End Current ............................ 31 + 4.2.3 The DS3 Far End Interval ........................... 34 + 4.2.4 The DS3 Far End Total .............................. 36 + 4.3 The DS3/E3 Fractional Group .......................... 38 + 5. Acknowledgments ....................................... 41 + 6. References ............................................ 41 + 7. Security Considerations ............................... 43 + 8. Authors' Addresses .................................... 43 + +1. The Network Management Framework + + The Internet-standard Network Management Framework consists of three + components. They are: + + STD 16/RFC 1155 which defines the SMI, the mechanisms used for + describing and naming objects for the purpose of management. STD + 16/RFC 1212 defines a more concise description mechanism, which is + wholly consistent with the SMI. + + RFC 1156 which defines MIB-I, the core set of managed objects for + the Internet suite of protocols. STD 17/RFC 1213, defines MIB-II, + an evolution of MIB-I based on implementation experience and new + operational requirements. + + STD 15/RFC 1157 which defines the SNMP, the protocol used for + network access to managed objects. + + The Framework permits new objects to be defined for the purpose of + experimentation and evaluation. + +2. Objects + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. Objects in the MIB are + defined using the subset of Abstract Syntax Notation One (ASN.1) [7] + defined in the SMI. In particular, each object has a name, a syntax, + and an encoding. The name is an object identifier, an + administratively assigned name, which specifies an object type. The + object type together with an object instance serves to uniquely + identify a specific instantiation of the object. For human + convenience, we often use a textual string, termed the OBJECT + DESCRIPTOR, to also refer to the object type. + + + +Trunk MIB Working Group [Page 2] + +RFC 1407 DS3/E3 MIB January 1993 + + + The syntax of an object type defines the abstract data structure + corresponding to that object type. The ASN.1 language is used for + this purpose. However, the SMI [3] purposely restricts the ASN.1 + constructs which may be used. These restrictions are explicitly made + for simplicity. + + The encoding of an object type is simply how that object type is + represented using the object type's syntax. Implicitly tied to the + notion of an object type's syntax and encoding is how the object type + is represented when being transmitted on the network. The SMI + specifies the use of the basic encoding rules of ASN.1 [8], subject + to the additional requirements imposed by the SNMP. + +2.1. Format of Definitions + + Section 4 contains contains the specification of all object types + contained in this MIB module. The object types are defined using the + conventions defined in the SMI, as amended by the extensions + specified in STD 16, RFC 1212 [13]. + +2.2. Changes from RFC 1233 + + This MIB obsoletes RFC 1233. The changes from RFC 1233 are the + following: + + -- This MIB module contains information to manage + an E3 interface, also. + + -- This MIB module contains three groups: + DS3/E3 Near End Group which is mandatory, + DS3 Far End Group which is optional, and + DS3 Fractional Group which is optional. + + -- The DS3 Far End Group is a new group and contains + configuration information and statistics + that are collected from the far end DS3/E3 interface. + Presently, the Far End Group may only be implemented by + DS3 systems that use C-bit Parity or SYNTRAN. + + -- The DS3 Fractional Group is a new group and is + modeled after the DS1 Fractional Group. + + -- ds3CSUIndex has been redefined and renamed + to dsx3LineIndex. This object + is the identifier of a DS3/E3 Interface on a device. + On a CSU, a single DS3/E3 data stream will cross two DS3/E3 + interfaces, which have separate dsx3LineIndex values. + + + + +Trunk MIB Working Group [Page 3] + +RFC 1407 DS3/E3 MIB January 1993 + + + -- ds3Index has been redefined and renamed to + dsx3IfIndex. This value for this + object is equal to the value of ifIndex from the Interfaces + table of MIB II (STD 17, RFC 1213). + + -- The ACCESS for objects in the dsx3ConfigTable has + been set to read-write for items that are configurable. + + -- The dsx3ZeroCoding has been renamed to dsx3LineCoding. + + -- A new object has been added called dsx3LoopbackConfig, + which better describes the loopback capabilities of + a DS3/E3 interface on a device. + + -- The dsx3SendCode object has been updated to reflect + different types of loopback messages. + + -- A new object has been added called dsx3LineStatus. + This object better describes the status (e.g., + failure state and loopback state) of a + DS3/E3 interface. + + -- A new object has been added called dsx3TransmitClockSource. + This object identifies the source for the transmit clock. + + -- All Counters have been changed to Gauges. + + -- A Line Errored Seconds object has been added to + all near end tables. + + -- Line Coding Violations are counted instead of Bipolar + Violations. + + -- A new Coding Violation counter has been added to count + coding violations reported via the C-bits of SYNTRAN + and C-bit Parity DS3 applications. + The original Coding Violation counter has been renamed + to PCV to mean coding violations reported via the P-bits. + This count is also added for symmetry with the far end + statistics. + + -- A new Errored Second counter and Severely Errored Second + counter has been added to count these performance events + via the C-bits of the SYNTRAN and C-bit Parity DS3 + applications. The original ES and SES counters have been + renamed to PES and PSES to mean reported via the P-bits. + These counts are also added for symmetry with the far end + statistics. + + + +Trunk MIB Working Group [Page 4] + +RFC 1407 DS3/E3 MIB January 1993 + + +3. Overview + + These objects are used when the particular media being used to + realize an interface is a DS3/E3 interface. At present, this applies + to these values of the ifType variable in the Internet-standard MIB: + + ds3 (30) + + The DS3 definitions contained herein are based on the DS3 + specifications in ANSI T1.102-1987, ANSI T1.107-1988, ANSI T1.107a- + 1990, and ANSI T1.404-1989 [9,10,10a,11]. The E3 definitions + contained herein are based on the E3 specifications in CCITT G.751 + [14]. + +3.1. Binding between ifIndex and DS3/E3 Interfaces + + Different physical configurations for the support of SNMP with DS3/E3 + equipment exist. To accommodate these scenarios, two different + indices for DS3/E3 interfaces are introduced in this MIB. These + indices are dsx3IfIndex and dsx3LineIndex. + + External interface scenario: the SNMP Agent represents all managed + DS3/E3 lines as external interfaces (for example, an Agent residing + on the device supporting DS3/E3 interfaces directly): + + For this scenario, all interfaces are assigned an integer value equal + to ifIndex, and the following applies: + + ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces. + + The dsx3IfIndex column of the DS3/E3 Configuration table relates each + DS3/E3 interface to its corresponding interface (ifIndex) in the + Internet-standard MIB (MIB-II STD 17, RFC 1213). + + External&Internal interface scenario: the SNMP Agents resides on an + host external from the device supporting DS3/E3 interfaces (e.g., a + router). The Agent represents both the host and the DS3/E3 device. + The index dsx3LineIndex is used to not only represent the DS3/E3 + interfaces external from the host/DS3/E3-device combination, but also + the DS3/E3 interfaces connecting the host and the DS3/E3 device. The + index dsx3IfIndex is always equal to ifIndex. + + Example: + + A shelf full of CSUs connected to a Router. An SNMP Agent residing on + the router proxies for itself and the CSU. The router has also an + Ethernet interface: + + + + +Trunk MIB Working Group [Page 5] + +RFC 1407 DS3/E3 MIB January 1993 + + + +-----+ + | | | + | | | +---------------------+ + |E | | 44.736 MBPS | ds3 M13 Line#A | ds3 C-bit Parity + |t | R |---------------+ - - - - - - - - - +------> + |h | | | | + |e | O | 44.736 MBPS | ds3 M13 Line#B | ds3 C-bit Parity + |r | |---------------+ - - - - - - - - - - +------> + |n | U | | | + |e | | 44.736 MBPS | ds3 M13 Line#C | ds3 C-bit Parity + |t | T |---------------+ - - - -- -- - - - - +------> + | | | | | + |-----| E | 44.736 MBPS | ds3 M13 Line#D | ds3 C-bit Parity + | | |---------------+ - - - - -- - - - - +------> + | | R | |_____________________| + | | | + | +-----+ + + The assignment of the index values could for example be: + + ifIndex (= dsx3IfIndex) dsx3LineIndex + + 1 NA NA (Ethernet) + 2 Line#A Router Side 6 + 2 Line#A Network Side 7 + 3 Line#B Router Side 8 + 3 Line#B Network Side 9 + 4 Line#C Router Side 10 + 4 Line#C Network Side 11 + 5 Line#D Router Side 12 + 5 Line#D Network Side 13 + + For this example, ifNumber is equal to 5. Note the following + description of dsx3LineIndex: the dsx3LineIndex identifies a DS3/E3 + Interface on a managed device. If there is an ifEntry that is + directly associated with this and only this DS3/E3 interface, it + should have the same value as ifIndex. Otherwise, number the + dsx3LineIndices with an unique identifier following the rules of + choosing a number greater than ifNumber and numbering inside + interfaces (e.g., equipment side) with even numbers and outside + interfaces (e.g., network side) with odd numbers. + + If the CSU shelf is managed by itself by a local SNMP Agent, the + situation would be: + + + + + + + +Trunk MIB Working Group [Page 6] + +RFC 1407 DS3/E3 MIB January 1993 + + + ifIndex (= dsx3IfIndex) dsx3LineIndex + + 1 Line#A Network Side 1 + 2 Line#A RouterSide 2 + 3 Line#B Network Side 3 + 4 Line#B RouterSide 4 + 5 Line#C Network Side 5 + 6 Line#C Router Side 6 + 7 Line#D Network Side 7 + 8 Line#D Router Side 8 + +3.2. Objectives of this MIB Module + + There are numerous things that could be included in a MIB for DS3/E3 + signals: the management of multiplexors, CSUs, DSUs, and the like. + The intent of this document is to facilitate the common management of + all devices with DS3/E3 interfaces. As such, a design decision was + made up front to very closely align the MIB with the set of objects + that can generally be read from DS3/E3 devices that are currently + deployed. + +3.3. DS3/E3 Terminology + + The terminology used in this document to describe error conditions on + a DS3 interface as monitored by a DS3 device are based on the + definitions from the ANSI T1M1.3/92-005R1 draft standard [12]. If + the definition in this document does not match the definition in the + ANSI T1M1.3/92-005R1 draft document, the implementer should follow + the definition described in this document. + +3.3.1. Error Events + + Bipolar Violation (BPV) Error Event + A bipolar violation error event, for B3ZS(HDB3)-coded + signals, is the occurrence of a pulse of the same polarity + as the previous pulse without being part of the zero + substitution code, B3ZS(HDB3). For B3ZS(HDB3)-coded + signals, a bipolar violation error event may also include + other error patterns such as: three(four) or more + consecutive zeros and incorrect polarity. + + Excessive Zeros (EXZ) Error Event + An EXZ is the occurrence of any zero string length equal + to or greater than 3 for B3ZS, or greater than 4 for HDB3. + + Line Coding Violation (LCV) Error Event + This parameter is a count of both BPVs and EXZs + occurring over the accumulation period. An EXZ + + + +Trunk MIB Working Group [Page 7] + +RFC 1407 DS3/E3 MIB January 1993 + + + increments the LCV by one regardless of the length + of the zero string. + + P-bit Coding Violation (PCV) Error Event + For all DS3 applications, a coding violation error + event is a P-bit + Parity Error event. A P-bit Parity Error event is the + occurrence of a received P-bit code on the DS3 M-frame + that is not identical to the corresponding locally- + calculated code. + + C-bit Coding Violation (CCV) Error Event + For C-bit Parity and SYNTRAN DS3 applications, this is + the count of coding violations reported via the C-bits. + For C-bit Parity, it is a count of CP-bit parity errors + occurring in the accumulation interval. For SYNTRAN, it + is a count of CRC-9 errors occurring in the accumulation + interval. + +3.3.2. Performance Parameters + + All performance parameters are accumulated in fifteen minute + intervals and up to 96 intervals (24 hours worth) are kept by an + agent. Fewer than 96 intervals of data will be available if the + agent has been restarted within the last 24 hours. In addition, + there is a rolling 24-hour total of each performance parameter. + + There is no requirement for an agent to ensure fixed relationship + between the start of a fifteen minute interval and any wall clock; + however some agents may align the fifteen minute intervals with + quarter hours. + + Line Errored Seconds (LES) + A Line Errored Second is a second in + which one or more CVs occurred OR one or more LOS defects. + + P-bit Errored Seconds (PES) + An PES is a second with one or more PCVs OR + one or more Out of Frame defects OR a detected incoming AIS. + This gauge is not incremented when UASs are counted. + + P-bit Severely Errored Seconds (PSES) + A PSES is a second with 44 or more PCVs OR + one or more Out of Frame defects OR a detected incoming AIS. + This gauge is not incremented when UASs are counted. + + C-bit Errored Seconds (CES) + An CES is a second with one or more CCVs OR + + + +Trunk MIB Working Group [Page 8] + +RFC 1407 DS3/E3 MIB January 1993 + + + one or more Out of Frame defects OR a detected incoming AIS. + This count is only for the SYNTRAN and C-bit Parity DS3 + applications. This gauge is not incremented when UASs are + counted. + + C-bit Severely Errored Seconds (CSES) + A CSES is a second with 44 or more CCVs OR + one or more Out of Frame defects OR a detected incoming AIS. + This count is only for the SYNTRAN and C-bit Parity DS3 + applications. This gauge is not incremented when UASs + are counted. + + Severely Errored Framing Seconds (SEFS) + A SEFS is a second with one or more Out of Frame defects + OR a detected incoming AIS. + + Unavailable Seconds (UAS) + UAS are calculated by counting the number of seconds that + the interface is unavailable. The DS3 interface is said + to be unavailable from the onset of 10 contiguous PSESs, or + the onset of the condition leading to a failure (see Failure + States). If the condition leading to the failure was + immediately preceded by one or more contiguous PSESs, then + the DS3 interface unavailability starts from the onset of + these PSESs. Once unavailable, and if no failure is + present, the DS3 interface becomes available at the onset + of 10 contiguous seconds with no PSESs. Once unavailable, + and if a failure is present, the DS3 interface becomes + available at the onset of 10 contiguous seconds with no + PSESs, if the failure clearing time is less than + or equal to 10 seconds. If the failure clearing time is + more than 10 seconds, the DS3 interface becomes available + at the onset of 10 contiguous seconds with no PSESs, or + the onset period leading to the successful clearing + condition, whichever occurs later. With respect to the + DS3 error counts, all counters are incremented + while the DS3 interface is deemed available. While the + interface is deemed unavailable, the only count that is + incremented is UASs. + + A special case exists when the 10 or more second period + crosses the 900 second statistics window boundary, as the + foregoing description implies that the PSES and UAS + counters must be adjusted when the Unavailable Signal + State is entered. Clearly, successive GETs of the + affected dsx3IntervalPSESs and dsx3IntervalUASs objects + will return differing values if the first GET occurs + during the first few seconds of the window. This is + + + +Trunk MIB Working Group [Page 9] + +RFC 1407 DS3/E3 MIB January 1993 + + + viewed as an unavoidable side-effect of selecting the + presently defined managed objects as a basis for this + memo. + +3.3.3. Performance Defects + + Failure States: + The Remote Alarm Indication (RAI) failure, in SYNTRAN + applications, is declared after detecting + the Yellow Alarm Signal on the alarm channel. See ANSI + T1.107a-1990 [10]. The Remote Alarm Indication failure, + in C-bit Parity DS3 applications, is declared + as soon as the preqsence of either one or two alarm signals + are detected on then Far End Alarm Channel. See [10]. + The Remote Alarm Indication failure may also be declared + after detecting the far-end SEF/AIS defect (aka yellow). + The Remote Alarm Indication failure is cleared as soon as + the presence of the any of the above alarms are removed. + + Also, the incoming failure state is declared when a defect + persists for at least 2-10 seconds. The defects are + the following: Loss of Signal (LOS), an Out of Frame (OOF) + or an incoming Alarm Indication Signal (AIS). + The Failure State is cleared when the defect is absent + for less than or equal to 20 seconds. + + Far End SEF/AIS defect (aka yellow) + A Far End SEF/AIS defect is the occurrence of the two X-bits + in a M-frame set to zero. The Far End SEF/AIS defect is + terminated when the two X-bits in a M-frame are set to + one. + + Out of Frame (OOF) defect + A DS3 OOF defect is detected when any three or more errors + in sixteen or fewer consecutive F-bits occur within a DS3 + M-frame. An OOF defect may also be called a Severely + Errored Frame (SEF) defect. An OOF defect is cleared when + reframe occurs. A DS3 Loss of Frame (LOF) failure is + declared when the DS3 OOF defect is consistent for 2 to 10 + seconds. The DS3 OOF defect ends when reframe occurs. + The DS3 LOF failure is cleared when the DS3 OOF + defect is absent for 10 to 20 seconds. + + An E3 OOF defect is detected when four consecutive frame + alignment signals have been incorrectly received in there + predicted positions in an E3 signal. E3 frame alignment + occurs when the presence of three consecutive frame + alignment signals have been detected. + + + +Trunk MIB Working Group [Page 10] + +RFC 1407 DS3/E3 MIB January 1993 + + + Loss of Signal (LOS) defect + The DS3 LOS defect is declared upon observing 175 +/- 75 + contiguous pulse positions with no pulses of either + positive or negative polarity. + The DS3 LOS defect is terminated upon observing an average + pulse density of at least 33% over a period of 175 +/- 75 + contiguous pulse positions starting with the receipt of a + pulse. + + Alarm Indication Signal (AIS) defect + The DS3 AIS is framed with "stuck stuffing." This implies + that it has a valid M-subframe alignments bits, M-frame + alignment bits, and P bits. The information bits are set + to a 1010... sequence, starting with a one (1) after each + M-subframe alignment bit, M-frame alignment bit, X bit, P + bit, and C bit. The C bits are all set to zero giving + what is called "stuck stuffing." The X bits are set to + one. The DS3 AIS defect is declared after DS3 AIS is + present in contiguous M-frames for a time equal to or + greater than T, where 0.2 ms <= T <= 100 ms. + The DS3 AIS defect is terminated after AIS is absent in + contiguous M-frames for a time equal to or greater than T. + + The E3 binary content of the AIS is nominally a continuous + stream of ones. AIS detection and the application of + consequent actions, should be completed within a time + limit of 1 ms. + +3.3.4. Other Terms + + Circuit Identifier + This is a character string specified by the circuit + vendor, and is useful when communicating with the vendor + during the troubleshooting process. + + + + + + + + + + + + + + + + + +Trunk MIB Working Group [Page 11] + +RFC 1407 DS3/E3 MIB January 1993 + + +4. Object Definitions + + RFC1407-MIB DEFINITIONS ::= BEGIN + + IMPORTS + Gauge + FROM RFC1155-SMI + DisplayString, transmission + FROM RFC1213-MIB + OBJECT-TYPE + FROM RFC-1212; + + -- This MIB module uses the extended OBJECT-TYPE macro + -- as defined in RFC 1212. + + ds3 OBJECT IDENTIFIER ::= { transmission 30 } + + + -- The DS3/E3 Near End Group + + -- Implementation of this group is mandatory for all + -- systems that attach to a DS3/E3 Interface. + + -- The DS3/E3 Near End Group consists of four tables: + -- DS3/E3 Configuration + -- DS3/E3 Current + -- DS3/E3 Interval + -- DS3/E3 Total + + -- the DS3/E3 Configuration + + dsx3ConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3ConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3/E3 Configuration table." + ::= { ds3 5 } + + dsx3ConfigEntry OBJECT-TYPE + SYNTAX Dsx3ConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3/E3 Configuration table." + INDEX { dsx3LineIndex } + ::= { dsx3ConfigTable 1 } + + + + +Trunk MIB Working Group [Page 12] + +RFC 1407 DS3/E3 MIB January 1993 + + + Dsx3ConfigEntry ::= + SEQUENCE { + dsx3LineIndex + INTEGER, + dsx3IfIndex + INTEGER, + dsx3TimeElapsed + INTEGER, + dsx3ValidIntervals + INTEGER, + dsx3LineType + INTEGER, + dsx3LineCoding + INTEGER, + dsx3SendCode + INTEGER, + dsx3CircuitIdentifier + DisplayString, + dsx3LoopbackConfig + INTEGER, + dsx3LineStatus + INTEGER, + dsx3TransmitClockSource + INTEGER + } + + dsx3LineIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object is the identifier of a DS3/E3 + Interface on a managed device. If there is an + ifEntry that is directly associated with this + and only this DS3/E3 interface, it should have + the same value as ifIndex. Otherwise, number + the dsx3LineIndices with an unique identifier + following the rules of choosing a number that + is greater than ifNumber and numbering the + inside interfaces (e.g., equipment side) with + even numbers and outside interfaces (e.g, + network side) with odd numbers." + ::= { dsx3ConfigEntry 1 } + + dsx3IfIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + + + +Trunk MIB Working Group [Page 13] + +RFC 1407 DS3/E3 MIB January 1993 + + + DESCRIPTION + "This value for this object is equal to the + value of ifIndex from the Interfaces table of + MIB II (RFC 1213)." + ::= { dsx3ConfigEntry 2 } + + dsx3TimeElapsed OBJECT-TYPE + SYNTAX INTEGER (0..899) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of seconds that have elapsed since + the beginning of the near end current error- + measurement period." + ::= { dsx3ConfigEntry 3 } + + dsx3ValidIntervals OBJECT-TYPE + SYNTAX INTEGER (0..96) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of previous near end intervals for + which valid data was collected. The value will be + 96 unless the interface was brought online within + the last 24 hours, in which case the value will be + the number of complete 15 minute near end + intervals since the interface has been online." + ::= { dsx3ConfigEntry 4 } + + dsx3LineType OBJECT-TYPE + SYNTAX INTEGER { + dsx3other(1), + dsx3M23(2), + dsx3SYNTRAN(3), + dsx3CbitParity(4), + dsx3ClearChannel(5), + e3other(6), + e3Framed(7), + e3Plcp(8) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable indicates the variety of DS3 C-bit + or E3 application + implementing this interface. The type of + interface affects the interpretation of the + usage and error statistics. + + + +Trunk MIB Working Group [Page 14] + +RFC 1407 DS3/E3 MIB January 1993 + + + The rate of DS3 is 44.736 Mbps and E3 is + 34.368 Mbps. + The dsx3ClearChannel value means that the C-bits + are not used except for sending/receiving + AIS. + + The values, in sequence, describe: + + TITLE: SPECIFICATION: + dsx3M23 ANSI T1.107-1988 + dsx3SYNTRAN ANSI T1.107-1988 + dsx3CbitParity ANSI T1.107a-1989 + dsx3ClearChannel ANSI T1.102-1987 + e3Framed CCITT G.751 + e3Plcp ETSI T/NA(91)18." + ::= { dsx3ConfigEntry 5 } + + dsx3LineCoding OBJECT-TYPE + SYNTAX INTEGER { + dsx3Other(1), + dsx3B3ZS(2), + e3HDB3(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable describes the variety of Zero Code + Suppression used on this interface, which in turn + affects a number of its characteristics. + + dsx3B3ZS and e3HDB3 refer to the use of specified + patterns of normal bits and bipolar violations + which are used to replace sequences of zero bits + of a specified length." + ::= { dsx3ConfigEntry 6 } + + dsx3SendCode OBJECT-TYPE + SYNTAX INTEGER { + dsx3SendNoCode(1), + dsx3SendLineCode(2), + dsx3SendPayloadCode(3), + dsx3SendResetCode(4), + dsx3SendDS1LoopCode(5), + dsx3SendTestPattern(6) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + + + +Trunk MIB Working Group [Page 15] + +RFC 1407 DS3/E3 MIB January 1993 + + + "This variable indicates what type of code is + being sent across the DS3/E3 interface by the + device. (These are optional for E3 interfaces.) + The values mean: + + dsx3SendNoCode + sending looped or normal data + + dsx3SendLineCode + sending a request for a line loopback + + dsx3SendPayloadCode + sending a request for a payload loopback + (i.e., all DS1/E1s in a DS3/E3 frame) + + dsx3SendResetCode + sending a loopback deactivation request + + dsx3SendDS1LoopCode + requesting to loopback a particular DS1/E1 + within a DS3/E3 frame + + dsx3SendTestPattern + sending a test pattern." + ::= { dsx3ConfigEntry 7 } + + dsx3CircuitIdentifier OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable contains the transmission vendor's + circuit identifier, for the purpose of + facilitating troubleshooting." + ::= { dsx3ConfigEntry 8 } + + dsx3LoopbackConfig OBJECT-TYPE + SYNTAX INTEGER { + dsx3NoLoop(1), + dsx3PayloadLoop(2), + dsx3LineLoop(3), + dsx3OtherLoop(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This variable represents the loopback configuration + of the DS3/E3 interface. + + + +Trunk MIB Working Group [Page 16] + +RFC 1407 DS3/E3 MIB January 1993 + + + The values mean: + + dsx3NoLoop + Not in the loopback state. A device that is + not capable of performing a loopback on + the interface shall always return this as + it's value. + + dsx3PayloadLoop + The received signal at this interface is looped + through the device. + Typically the received signal + is looped back for retransmission after it has + passed through the device's framing function. + + dsx3LineLoop + The received signal at this interface does not + go through the device (minimum penetration) but + is looped back out. + + dsx3OtherLoop + Loopbacks that are not defined here." + ::= { dsx3ConfigEntry 9 } + + dsx3LineStatus OBJECT-TYPE + SYNTAX INTEGER (1..1023) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This variable indicates the + Line Status of the interface. + It contains loopback state information + and failure state information. + The dsx3LineStatus is a bit map represented + as a sum, therefore, + it can represent multiple failures + and a loopback (see dsx3LoopbackConfig object + for the type of loopback) + simultaneously. + The dsx3NoAlarm should be set if and only if + no other flag is set. + + The various bit positions are: + 1 dsx3NoAlarm No alarm present + 2 dsx3RcvRAIFailure Receiving Yellow/Remote + Alarm Indication + 4 dsx3XmitRAIAlarm Transmitting Yellow/Remote + Alarm Indication + + + +Trunk MIB Working Group [Page 17] + +RFC 1407 DS3/E3 MIB January 1993 + + + 8 dsx3RcvAIS Receiving AIS failure state + 16 dsx3XmitAIS Transmitting AIS + 32 dsx3LOF Receiving LOF failure state + 64 dsx3LOS Receiving LOS failure state + 128 dsx3LoopbackState Looping the received signal + 256 dsx3RcvTestCode Receiving a Test Pattern + 512 dsx3OtherFailure any line status not defined + here" + ::= { dsx3ConfigEntry 10 } + + dsx3TransmitClockSource OBJECT-TYPE + SYNTAX INTEGER { + loopTiming(1), + localTiming(2), + throughTiming(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The source of Transmit Clock. + is derived from the recovered receive clock of + another DS3 interface." + ::= { dsx3ConfigEntry 11 } + + + -- the DS3/E3 Current + + -- The DS3/E3 current table contains various statistics being + -- collected for the current 15 minute interval. + + dsx3CurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3CurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3/E3 Current table." + ::= { ds3 6 } + + dsx3CurrentEntry OBJECT-TYPE + SYNTAX Dsx3CurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3/E3 Current table." + INDEX { dsx3CurrentIndex } + ::= { dsx3CurrentTable 1 } + + + + + +Trunk MIB Working Group [Page 18] + +RFC 1407 DS3/E3 MIB January 1993 + + + Dsx3CurrentEntry ::= + SEQUENCE { + dsx3CurrentIndex + INTEGER, + dsx3CurrentPESs + Gauge, + dsx3CurrentPSESs + Gauge, + dsx3CurrentSEFSs + Gauge, + dsx3CurrentUASs + Gauge, + dsx3CurrentLCVs + Gauge, + dsx3CurrentPCVs + Gauge, + dsx3CurrentLESs + Gauge, + dsx3CurrentCCVs + Gauge, + dsx3CurrentCESs + Gauge, + dsx3CurrentCSESs + Gauge + } + + dsx3CurrentIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3/E3 interface to which this entry is + applicable. The interface identified by a + particular value of this index is the same + interface as identified by the same value an + dsx3LineIndex object instance." + ::= { dsx3CurrentEntry 1 } + + dsx3CurrentPESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Errored Seconds, encountered by a DS3 interface in + the current 15 minute interval." + ::= { dsx3CurrentEntry 2 } + + + +Trunk MIB Working Group [Page 19] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3CurrentPSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Severely Errored Seconds, encountered by a DS3 + interface in the current 15 minute interval." + ::= { dsx3CurrentEntry 3 } + + dsx3CurrentSEFSs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Severely Errored Framing Seconds, encountered by a + DS3/E3 interface in the current 15 minute + interval." + ::= { dsx3CurrentEntry 4 } + + dsx3CurrentUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, encountered by a DS3 + interface in the current 15 minute interval." + ::= { dsx3CurrentEntry 5 } + + dsx3CurrentLCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of Line + Coding Violations encountered by a DS3/E3 + interface in the current 15 minute interval." + ::= { dsx3CurrentEntry 6 } + + dsx3CurrentPCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Coding Violations, encountered by a DS3 interface + + + +Trunk MIB Working Group [Page 20] + +RFC 1407 DS3/E3 MIB January 1993 + + + in the current 15 minute interval." + ::= { dsx3CurrentEntry 7 } + + dsx3CurrentLESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Line Errored Seconds encountered by + a DS3/E3 interface in the current 15 minute + interval." + ::= { dsx3CurrentEntry 8 } + + dsx3CurrentCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Coding Violations encountered + by a DS3 interface in the current 15 minute + interval." + ::= { dsx3CurrentEntry 9 } + + dsx3CurrentCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Errored Seconds encountered + by a DS3 interface in the current 15 minute + interval." + ::= { dsx3CurrentEntry 10 } + + dsx3CurrentCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Severely Errored Seconds + encountered by a DS3 interface in the current 15 + minute interval." + ::= { dsx3CurrentEntry 11 } + + + -- the DS3/E3 Interval + + -- The DS3/E3 Interval Table contains various statistics + -- collected by each DS3/E3 Interface over the previous 24 + + + +Trunk MIB Working Group [Page 21] + +RFC 1407 DS3/E3 MIB January 1993 + + + -- hours of operation. The past 24 hours are broken into 96 + -- completed 15 minute intervals. + + dsx3IntervalTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3IntervalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3/E3 Interval table." + ::= { ds3 7 } + + dsx3IntervalEntry OBJECT-TYPE + SYNTAX Dsx3IntervalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3/E3 Interval table." + INDEX { dsx3IntervalIndex, dsx3IntervalNumber } + ::= { dsx3IntervalTable 1 } + + Dsx3IntervalEntry ::= + SEQUENCE { + dsx3IntervalIndex + INTEGER, + dsx3IntervalNumber + INTEGER, + dsx3IntervalPESs + Gauge, + dsx3IntervalPSESs + Gauge, + dsx3IntervalSEFSs + Gauge, + dsx3IntervalUASs + Gauge, + dsx3IntervalLCVs + Gauge, + dsx3IntervalPCVs + Gauge, + dsx3IntervalLESs + Gauge, + dsx3IntervalCCVs + Gauge, + dsx3IntervalCESs + Gauge, + dsx3IntervalCSESs + Gauge + } + + + + +Trunk MIB Working Group [Page 22] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3IntervalIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3/E3 interface to which this entry is + applicable. The interface identified by a + particular value of this index is the same + interface as identified by the same value an + dsx3LineIndex object instance." + ::= { dsx3IntervalEntry 1 } + + dsx3IntervalNumber OBJECT-TYPE + SYNTAX INTEGER (1..96) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A number between 1 and 96, where 1 is the most + recently completed 15 minute interval and 96 is + the least recently completed 15 minutes interval + (assuming that all 96 intervals are valid)." + ::= { dsx3IntervalEntry 2 } + + dsx3IntervalPESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Errored Seconds, encountered by a DS3 interface in + one of the previous 96, individual 15 minute, + intervals." + ::= { dsx3IntervalEntry 3 } + + dsx3IntervalPSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Severely Errored Seconds, encountered by a DS3 + interface in one of the previous 96, individual 15 + minute, intervals." + ::= { dsx3IntervalEntry 4 } + + dsx3IntervalSEFSs OBJECT-TYPE + SYNTAX Gauge + + + +Trunk MIB Working Group [Page 23] + +RFC 1407 DS3/E3 MIB January 1993 + + + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Severely Errored Framing Seconds, encountered by a + DS3/E3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3IntervalEntry 5 } + + dsx3IntervalUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, encountered by a DS3 + interface in one of the previous 96, individual 15 + minute, intervals." + ::= { dsx3IntervalEntry 6 } + + dsx3IntervalLCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of Line + Coding Violations encountered by a DS3/E3 + interface in one of the previous 96, individual 15 + minute, intervals." + ::= { dsx3IntervalEntry 7 } + + dsx3IntervalPCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Coding Violations, encountered by a DS3 interface + in one of the previous 96, individual 15 minute, + intervals." + ::= { dsx3IntervalEntry 8 } + + dsx3IntervalLESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Line Errored Seconds (BPVs or + + + +Trunk MIB Working Group [Page 24] + +RFC 1407 DS3/E3 MIB January 1993 + + + illegal zero sequences) encountered by a DS3/E3 + interface in one of the previous 96, individual + 15 minute, intervals." + ::= { dsx3IntervalEntry 9 } + + dsx3IntervalCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Coding Violations encountered + by a DS3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3IntervalEntry 10 } + + dsx3IntervalCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Errored Seconds encountered + by a DS3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3IntervalEntry 11 } + + dsx3IntervalCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Severely Errored Seconds + encountered by a DS3 interface in one of the + previous 96, individual 15 minute, intervals." + ::= { dsx3IntervalEntry 12 } + + + -- the DS3/E3 Total + + -- The DS3/E3 Total Table contains the cumulative sum of the + -- various statistics for the 24 hour period preceding the + -- current interval. + + dsx3TotalTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3TotalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3/E3 Total table. 24 hour interval." + + + +Trunk MIB Working Group [Page 25] + +RFC 1407 DS3/E3 MIB January 1993 + + + ::= { ds3 8 } + + dsx3TotalEntry OBJECT-TYPE + SYNTAX Dsx3TotalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3/E3 Total table." + INDEX { dsx3TotalIndex } + ::= { dsx3TotalTable 1 } + + Dsx3TotalEntry ::= + SEQUENCE { + dsx3TotalIndex + INTEGER, + dsx3TotalPESs + Gauge, + dsx3TotalPSESs + Gauge, + dsx3TotalSEFSs + Gauge, + dsx3TotalUASs + Gauge, + dsx3TotalLCVs + Gauge, + dsx3TotalPCVs + Gauge, + dsx3TotalLESs + Gauge, + dsx3TotalCCVs + Gauge, + dsx3TotalCESs + Gauge, + dsx3TotalCSESs + Gauge + } + + dsx3TotalIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3/E3 interface to which this entry is + applicable. The interface identified by a + particular value of this index is the same + interface as identified by the same value an + dsx3LineIndex object instance." + + + +Trunk MIB Working Group [Page 26] + +RFC 1407 DS3/E3 MIB January 1993 + + + ::= { dsx3TotalEntry 1 } + + dsx3TotalPESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Errored Seconds, encountered by a DS3 interface in + the previous 24 hour interval" + ::= { dsx3TotalEntry 2 } + + dsx3TotalPSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Severely Errored Seconds, encountered by a DS3 + interface in the previous 24 hour interval." + ::= { dsx3TotalEntry 3 } + + dsx3TotalSEFSs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Severely Errored Framing Seconds, encountered by a + DS3/E3 interface in the previous 24 hour + interval." + ::= { dsx3TotalEntry 4 } + + dsx3TotalUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, encountered by a DS3 + interface in the previous 24 hour interval." + ::= { dsx3TotalEntry 5 } + + dsx3TotalLCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + + + +Trunk MIB Working Group [Page 27] + +RFC 1407 DS3/E3 MIB January 1993 + + + "The counter associated with the number of Line + Coding Violations encountered by a DS3/E3 + interface in the previous 24 hour interval." + ::= { dsx3TotalEntry 6 } + + dsx3TotalPCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of P-bit + Coding Violations, encountered by a DS3 interface + in the previous 24 hour interval." + ::= { dsx3TotalEntry 7 } + + dsx3TotalLESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of Line Errored Seconds (BPVs or + illegal zero sequences) encountered by a DS3/E3 + interface in the previous 24 hour interval." + ::= { dsx3TotalEntry 8 } + + dsx3TotalCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Coding Violations encountered + by a DS3 interface in the previous 24 hour + interval." + ::= { dsx3TotalEntry 9 } + + dsx3TotalCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of C-bit Errored Seconds encountered + by a DS3 interface in the previous 24 hour + interval." + ::= { dsx3TotalEntry 10 } + + dsx3TotalCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + + + +Trunk MIB Working Group [Page 28] + +RFC 1407 DS3/E3 MIB January 1993 + + + STATUS mandatory + DESCRIPTION + "The number of C-bit Severely Errored Seconds + encountered by a DS3 interface in the previous 24 + hour interval." + ::= { dsx3TotalEntry 11 } + + + -- The DS3 Far End Group + + -- Implementation of this group is optional for all systems + -- that attach to a DS3 Interface. + -- However, only C-bit Parity and SYNTRAN DS3 applications + -- have the capability (option) of providing this information. + + -- The DS3 Far End Group consists of four tables: + -- DS3 Far End Configuration + -- DS3 Far End Current + -- DS3 Far End Interval + -- DS3 Far End Total + + + -- The DS3 Far End Configuration Table contains + -- configuration information + -- reported in the C-bits from the remote end. + + dsx3FarEndConfigTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3FarEndConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3 Far End Configuration table." + ::= { ds3 9 } + + dsx3FarEndConfigEntry OBJECT-TYPE + SYNTAX Dsx3FarEndConfigEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3 Far End Configuration table." + INDEX { dsx3FarEndLineIndex } + ::= { dsx3FarEndConfigTable 1 } + + Dsx3FarEndConfigEntry ::= + SEQUENCE { + dsx3FarEndLineIndex + INTEGER, + dsx3FarEndEquipCode + + + +Trunk MIB Working Group [Page 29] + +RFC 1407 DS3/E3 MIB January 1993 + + + DisplayString, + dsx3FarEndLocationIDCode + DisplayString, + dsx3FarEndFrameIDCode + DisplayString, + dsx3FarEndUnitCode + DisplayString, + dsx3FarEndFacilityIDCode + DisplayString + } + + dsx3FarEndLineIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3 interface + to which this entry is applicable. The + interface identified by a particular value of + this index is the same interface as identified + by the same value an dsx3LineIndex object + instance." + ::= { dsx3FarEndConfigEntry 1 } + + dsx3FarEndEquipCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..10)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the Far End Equipment Identification code + that describes the specific piece of equipment. + It is sent within the Path + Identification Message." + ::= { dsx3FarEndConfigEntry 2 } + + dsx3FarEndLocationIDCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..11)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the Far End Location Identification code + that describes the specific location of the + equipment. + It is sent within the Path + Identification Message." + ::= { dsx3FarEndConfigEntry 3 } + + + + +Trunk MIB Working Group [Page 30] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3FarEndFrameIDCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..10)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the Far End Frame Identification code + that identifies where the equipment is located + within a building at a given location. + It is sent within the Path + Identification Message." + ::= { dsx3FarEndConfigEntry 4 } + + dsx3FarEndUnitCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..6)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This is the Far End code + that identifies the equipment location within a bay. + It is sent within the Path + Identification Message." + ::= { dsx3FarEndConfigEntry 5 } + + dsx3FarEndFacilityIDCode OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..38)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This code identifies a specific Far End DS3 path. + It is sent within the Path + Identification Message." + ::= { dsx3FarEndConfigEntry 6 } + + + -- The DS3 Far End Current + + -- The DS3 Far End Current table contains various statistics + -- being collected for the current 15 minute interval. + -- The statistics are collected from the far end block error + -- code within the C-bits. + + dsx3FarEndCurrentTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3FarEndCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3 Far End Current table." + ::= { ds3 10 } + + + +Trunk MIB Working Group [Page 31] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3FarEndCurrentEntry OBJECT-TYPE + SYNTAX Dsx3FarEndCurrentEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3 Far End Current table." + INDEX { dsx3FarEndCurrentIndex } + ::= { dsx3FarEndCurrentTable 1 } + + Dsx3FarEndCurrentEntry ::= + SEQUENCE { + dsx3FarEndCurrentIndex + INTEGER, + dsx3FarEndTimeElapsed + INTEGER, + dsx3FarEndValidIntervals + INTEGER, + dsx3FarEndCurrentCESs + Gauge, + dsx3FarEndCurrentCSESs + Gauge, + dsx3FarEndCurrentCCVs + Gauge, + dsx3FarEndCurrentUASs + Gauge + } + + dsx3FarEndCurrentIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3 interface + to which this entry is applicable. The interface + identified by a particular value of this index is + the same interface as identified by the same value + an dsx3LineIndex object instance." + ::= { dsx3FarEndCurrentEntry 1 } + + dsx3FarEndTimeElapsed OBJECT-TYPE + SYNTAX INTEGER (0..899) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of seconds that have elapsed since the + beginning of the far end current error-measurement + period." + + + +Trunk MIB Working Group [Page 32] + +RFC 1407 DS3/E3 MIB January 1993 + + + ::= { dsx3FarEndCurrentEntry 2 } + + dsx3FarEndValidIntervals OBJECT-TYPE + SYNTAX INTEGER (0..96) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of previous far end intervals for + which valid data was collected. The value will be + 96 unless the interface was brought online within + the last 24 hours, in which case the value will be + the number of complete 15 minute far end intervals + since the interface has been online." + ::= { dsx3FarEndCurrentEntry 3 } + + dsx3FarEndCurrentCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of Far + Far End C-bit Errored Seconds encountered by a DS3 + interface in the current 15 minute interval." + ::= { dsx3FarEndCurrentEntry 4 } + + dsx3FarEndCurrentCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End C-bit Severely Errored Seconds + encountered by a DS3 interface in the current 15 + minute interval." + ::= { dsx3FarEndCurrentEntry 5 } + + dsx3FarEndCurrentCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End C-bit Coding Violations reported via + the far end block error count + encountered by a + DS3 interface in the current 15 minute interval." + ::= { dsx3FarEndCurrentEntry 6 } + + + + +Trunk MIB Working Group [Page 33] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3FarEndCurrentUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End unavailable seconds + encountered by a + DS3 interface in the current 15 minute interval." + ::= { dsx3FarEndCurrentEntry 7 } + + + -- The DS3 Far End Interval + + -- The DS3 Far End Interval Table contains various statistics + -- collected by each DS3 interface over the previous 24 + -- hours of operation. The past 24 hours are broken into 96 + -- completed 15 minute intervals. + + dsx3FarEndIntervalTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3 Far End Interval table." + ::= { ds3 11 } + + dsx3FarEndIntervalEntry OBJECT-TYPE + SYNTAX Dsx3FarEndIntervalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3 Far + End Interval table." + INDEX { dsx3FarEndIntervalIndex, + dsx3FarEndIntervalNumber } + ::= { dsx3FarEndIntervalTable 1 } + + Dsx3FarEndIntervalEntry ::= + SEQUENCE { + dsx3FarEndIntervalIndex + INTEGER, + dsx3FarEndIntervalNumber + INTEGER, + dsx3FarEndIntervalCESs + Gauge, + dsx3FarEndIntervalCSESs + Gauge, + + + +Trunk MIB Working Group [Page 34] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3FarEndIntervalCCVs + Gauge, + dsx3FarEndIntervalUASs + Gauge + } + + dsx3FarEndIntervalIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3 interface + to which this entry is applicable. The + interface identified by a particular value of + this index is the same interface as identified + by the same value an dsx3LineIndex object + instance." + ::= { dsx3FarEndIntervalEntry 1 } + + dsx3FarEndIntervalNumber OBJECT-TYPE + SYNTAX INTEGER (1..96) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A number between 1 and 96, where 1 is the most + recently completed 15 minute interval and 96 is + the least recently completed 15 minutes + interval (assuming that all 96 intervals are + valid)." + ::= { dsx3FarEndIntervalEntry 2 } + + dsx3FarEndIntervalCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End C-bit Errored Seconds encountered + by a DS3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3FarEndIntervalEntry 3 } + + dsx3FarEndIntervalCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + + + +Trunk MIB Working Group [Page 35] + +RFC 1407 DS3/E3 MIB January 1993 + + + "The counter associated with the number of + Far End C-bit Severely Errored Seconds + encountered by a DS3 interface in one of the + previous 96, individual 15 minute, intervals." + ::= { dsx3FarEndIntervalEntry 4 } + + dsx3FarEndIntervalCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End C-bit Coding Violations reported via + the far end block error count + encountered by a + DS3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3FarEndIntervalEntry 5 } + + dsx3FarEndIntervalUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End unavailable seconds + encountered by a + DS3 interface in one of the previous 96, + individual 15 minute, intervals." + ::= { dsx3FarEndIntervalEntry 6 } + + + -- The DS3 Far End Total + + -- The DS3 Far End Total Table contains the cumulative sum + -- of the various statistics for the 24 hour period preceding + -- the current interval. + + dsx3FarEndTotalTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3 Far End Total table. 24 hour interval." + ::= { ds3 12 } + + dsx3FarEndTotalEntry OBJECT-TYPE + SYNTAX Dsx3FarEndTotalEntry + + + +Trunk MIB Working Group [Page 36] + +RFC 1407 DS3/E3 MIB January 1993 + + + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3 Far End Total table." + INDEX { dsx3FarEndTotalIndex } + ::= { dsx3FarEndTotalTable 1 } + + Dsx3FarEndTotalEntry ::= + SEQUENCE { + dsx3FarEndTotalIndex + INTEGER, + dsx3FarEndTotalCESs + Gauge, + dsx3FarEndTotalCSESs + Gauge, + dsx3FarEndTotalCCVs + Gauge, + dsx3FarEndTotalUASs + Gauge + } + + dsx3FarEndTotalIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3 interface + to which this entry is applicable. The interface + identified by a particular value of this index is + the same interface as identified by the same value + an dsx3LineIndex object instance." + ::= { dsx3FarEndTotalEntry 1 } + + dsx3FarEndTotalCESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of Far + End C-bit Errored Seconds encountered by a DS3 + interface in the previous 24 hour interval." + ::= { dsx3FarEndTotalEntry 2 } + + dsx3FarEndTotalCSESs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + + + +Trunk MIB Working Group [Page 37] + +RFC 1407 DS3/E3 MIB January 1993 + + + DESCRIPTION + "The counter associated with the number of + Far End C-bit Severely Errored Seconds + encountered by a DS3 interface in the previous 24 + hour interval." + ::= { dsx3FarEndTotalEntry 3 } + + dsx3FarEndTotalCCVs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End C-bit Coding Violations reported via the + far end block error count + encountered by a + DS3 interface in the previous 24 hour interval." + ::= { dsx3FarEndTotalEntry 4 } + + dsx3FarEndTotalUASs OBJECT-TYPE + SYNTAX Gauge + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The counter associated with the number of + Far End unavailable seconds + encountered by a + DS3 interface in the previous 24 hour interval." + ::= { dsx3FarEndTotalEntry 5 } + + + -- the DS3/E3 Fractional Group + + -- Implementation of this group is optional. It is designed + -- for those systems dividing a DS3/E3 into channels + -- containing different data streams that are of local + -- interest. + + -- The DS3/E3 fractional table identifies which DS3/E3 + -- channels associated with a CSU are being used to + -- support a logical interface, i.e., an entry in the + -- interfaces table from the Internet-standard MIB. + + -- For example, consider a DS3 device with 4 high speed links + -- carrying router traffic, a feed for voice, a feed for + -- video, and a synchronous channel for a non-routed + -- protocol. + -- We might describe the allocation of channels, in the + + + +Trunk MIB Working Group [Page 38] + +RFC 1407 DS3/E3 MIB January 1993 + + + -- dsx3FracTable, as follows: + + -- dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4 + -- dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6 + -- dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6 + -- dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6 + -- dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6 + -- dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6 + -- dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6 + -- dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6 + -- dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6 + -- dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6 + -- dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6 + -- dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6 + -- dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6 + -- dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6 + + -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and + -- dsx3ClearChannel there are 28 legal channels, numbered 1 + -- through 28. + + -- For e3Framed there are 16 legal channels, + -- numbered 1 through 16. The channels (1..16) correspond + -- directly to the equivalently numbered time-slots. + + dsx3FracTable OBJECT-TYPE + SYNTAX SEQUENCE OF Dsx3FracEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "The DS3 Fractional table." + ::= { ds3 13 } + + dsx3FracEntry OBJECT-TYPE + SYNTAX Dsx3FracEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An entry in the DS3 Fractional table." + INDEX { dsx3FracIndex, dsx3FracNumber } + ::= { dsx3FracTable 1 } + + Dsx3FracEntry ::= + SEQUENCE { + dsx3FracIndex + INTEGER, + dsx3FracNumber + INTEGER, + + + +Trunk MIB Working Group [Page 39] + +RFC 1407 DS3/E3 MIB January 1993 + + + dsx3FracIfIndex + INTEGER + } + + + dsx3FracIndex OBJECT-TYPE + SYNTAX INTEGER (1..'7fffffff'h) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index value which uniquely identifies the + DS3 interface to which this entry is applicable + The interface identified by a particular + value of this index is the same interface as + identified by the same value an dsx3LineIndex + object instance." + ::= { dsx3FracEntry 1 } + + dsx3FracNumber OBJECT-TYPE + SYNTAX INTEGER (1..31) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The channel number for this entry." + ::= { dsx3FracEntry 2 } + + dsx3FracIfIndex OBJECT-TYPE + SYNTAX INTEGER (1..'7fffffff'h) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An index value that uniquely identifies an + interface. The interface identified by a particular + value of this index is the same interface + as identified by the same value an ifIndex + object instance. If no interface is currently using + a channel, the value should be zero. If a + single interface occupies more than one time + slot, that ifIndex value will be found in multiple + time slots." + ::= { dsx3FracEntry 3 } + + + + END + + + + + + +Trunk MIB Working Group [Page 40] + +RFC 1407 DS3/E3 MIB January 1993 + + +5. Acknowledgments + +This document was produced by the Trunk MIB Working Groups: + + Tracy Cox Bellcore + Fred Baker Advanced Computer Communications + James Watt Newbridge + Bill Versteeg Versteeg Codeworks + Steve Buchko Newbridge + Greg Calmainis Newbridge + Kaj Tesink Bellcore + Al Bryenton Bell Northern Research + Tom Easterday CIC + John Labbe Merit Corporation + Chris Sullivan Gandalf Ltd + Grant Hall Gandalf Ltd + John Guerrero Digital Link + Rich Bradford BBN + Kurt Luoto Digital Link + Myron Hattig Kentrox + Ed Pring IBM + Larry Marks IBM + Kurt Hall Clear Communications Corp. + Jason Perreault Coral Network Corp. + Paul Farah T3plus + George Kajos Coral Network Corp. + +6. References + + [1] Cerf, V., "IAB Recommendations for the Development of Internet + Network Management Standards", RFC 1052, NRI, April 1988. + + [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review + Group", RFC 1109, NRI, August 1989. + + [3] Rose M., and K. McCloghrie, "Structure and Identification of + Management Information for TCP/IP-based internets", STD 16, RFC + 1155, Performance Systems International, Hughes LAN Systems, May + 1990. + + [4] McCloghrie K., and M. Rose, "Management Information Base for + Network Management of TCP/IP-based internets", RFC 1156, Hughes + LAN Systems, Performance Systems International, May 1990. + + [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple + Network Management Protocol", STD 15, RFC 1157, SNMP Research, + Performance Systems International, Performance Systems + International, MIT Laboratory for Computer Science, May 1990. + + + +Trunk MIB Working Group [Page 41] + +RFC 1407 DS3/E3 MIB January 1993 + + + [6] McCloghrie K., and M. Rose, Editors, "Management Information Base + for Network Management of TCP/IP-based internets", STD 17, RFC + 1213, Performance Systems International, March 1991. + + [7] Information processing systems - Open Systems Interconnection - + Specification of Abstract Syntax Notation One (ASN.1), + International Organization for Standardization, International + Standard 8824, December 1987. + + [8] Information processing systems - Open Systems Interconnection - + Specification of Basic Encoding Rules for Abstract Notation One + (ASN.1), International Organization for Standardization, + International Standard 8825, December 1987. + + [9] American National Standard for Telecommunications - Digital + Hierarchy - Electrical Interfaces, ANSI T1.102- 1987. + + [10] American National Standard for Telecommunications - Digital + Hierarchy - Formats Specification, ANSI T1.107- 1988. + + [10a] ANSI T1.107a-1990. + + [11] American National Standard for Telecommunications - Carrier-to- + Customer Installation - DS3 Metallic Interface, ANSI T1.404-1989. + + [12] American National Standard for Telecommunications -- Layer 1 In- + Service Digital Transmission Performance Monitoring T1M1/92-0xx, + T1M1.3/92-005R1, April 1992. + + [13] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", + STD 16, RFC 1212, Performance Systems International, Hughes LAN + Systems, March 1991. + + [14] CCITT - Digital Multiplex Equipment Operating at the Third Order + Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264 + Kbit/s and Using Positive Justification, G.751. + + [15] European Telecommunications Standards Institute -- ETS "34M" -- + Metropolitan Area Network Physical Convergence Layer Procedure + for 34.368 Megabits per Second, T/NA(91)18, May 1991. + + + + + + + + + + + +Trunk MIB Working Group [Page 42] + +RFC 1407 DS3/E3 MIB January 1993 + + +7. Security Considerations + + Security issues are not discussed in this memo. + +8. Authors' Addresses + + Tracy A. Cox + Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + + Phone: (908) 758-2107 + EMail: tacox@mail.bellcore.com + + + Kaj Tesink + Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + + Phone: (908) 758-5254 + EMail: kaj@cc.bellcore.com + + + + + + + + + + + + + + + + + + + + + + + + + + + +Trunk MIB Working Group [Page 43] +
\ No newline at end of file |