+Network Working Group N. Brownlee
+Request for Comments: 2064 The University of Auckland
+Category: Experimental January 1997
+
+
+ Traffic Flow Measurement: Meter MIB
+
+Status of this Memo
+
+ This memo defines an Experimental Protocol for the Internet
+ community. This memo does not specify an Internet standard of any
+ kind. Discussion and suggestions for improvement are requested.
+ Distribution of this memo is unlimited.
+
+Abstract
+
+ This memo defines a portion of the Management Information Base (MIB)
+ for use with network management protocols in TCP/IP-based internets.
+ In particular, this memo defines managed objects used for obtaining
+ traffic flow information from network traffic meters.
+
+Table of Contents
+
+ 1 The Network Management Framework . . . . . . . . . . . . . . . . 1
+ 2 Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
+ 2.1 Format of Definitions . . . . . . . . . . . . . . . . . . . 3
+ 3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
+ 3.1 Scope of Definitions, Textual Conventions . . . . . . . . . 3
+ 3.2 Usage of the MIB variables . . . . . . . . . . . . . . . . 4
+ 4 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . 6
+ 5 Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . 37
+ 6 References . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
+ 7 Security Considerations . . . . . . . . . . . . . . . . . . . . 38
+ 8 Author's Address . . . . . . . . . . . . . . . . . . . . . . . . 38
+
+1 The Network Management Framework
+
+ The Internet-standard Network Management Framework consists of three
+ components. They are:
+
+ RFC 1155 defines the SMI, the mechanisms used for describing and
+ naming objects for the purpose of management. STD 16, RFC 1212
+ defines a more concise description mechanism, which is wholly
+ consistent with the SMI.
+
+
+
+
+
+
+
+Brownlee Experimental [Page 1]
+
+RFC 2064 Meter MIB January 1997
+
+
+ RFC 1156 defines MIB-I, the core set of managed objects for the
+ Internet suite of protocols. STD 17, RFC 1213 [1] defines MIB-II,
+ an evolution of MIB-I based on implementation experience and new
+ operational requirements.
+
+ STD 15, RFC 1157 defines the SNMP, the protocol used for network
+ access to managed objects.
+
+ RFC 1442 [2] defines the SMI for version 2 of the Simple Network
+ Management Protocol.
+
+ RFCs 1443 and 1444 [3,4] define Textual Conventions and
+ Conformance Statements for version 2 of the Simple Network
+ Management Protocol.
+
+ RFC 1452 [5] describes how versions 1 and 2 of the Simple Network
+ Management Protocol should coexist.
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+2 Objects
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation One (ASN.1) [6]
+ defined in the SMI. In particular, each object has a name, a syntax,
+ and an encoding. The name is an object identifier, an
+ administratively assigned name, which specifies an object type. The
+ object type together with an object instance serves to uniquely
+ identify a specific instantiation of the object. For human
+ convenience, we often use a textual string, termed the OBJECT
+ DESCRIPTOR, to also refer to the object type.
+
+ The syntax of an object type defines the abstract data structure
+ corresponding to that object type. The ASN.1 language is used for
+ this purpose. However, the SMI [2] purposely restricts the ASN.1
+ constructs which may be used. These restrictions are explicitly made
+ for simplicity.
+
+ The encoding of an object type is simply how that object type is
+ represented using the object type's syntax. Implicitly tied to the
+ notion of an object type's syntax and encoding is how the object type
+ is represented when being transmitted on the network.
+
+ The SMI specifies the use of the basic encoding rules of ASN.1 [7],
+ subject to the additional requirements imposed by the SNMP.
+
+
+
+
+Brownlee Experimental [Page 2]
+
+RFC 2064 Meter MIB January 1997
+
+
+2.1 Format of Definitions
+
+ Section 4 contains contains the specification of all object types
+ contained in this MIB module. These object types are defined using
+ the conventions defined in [2] and [3].
+
+3 Overview
+
+ Traffic Flow Measurement seeks to provide a well-defined method for
+ gathering traffic flow information from networks and internetworks.
+ The background for this is given in "Traffic Flow Measurement:
+ Background" [8]. The Realtime Traffic Flow Measurement (rtfm)
+ Working Group has produced a measurement architecture to achieve it;
+ this is documented in "Traffic Flow Measurement: Architecture" [9].
+ The architecture defines three entities:
+
+ - METERS, which observe network traffic flows and build up a
+ table of flow data records for them,
+
+ - METER REAERS, which collect traffic flow data from meters, and
+
+ - MANAGERS, which oversee the operation of meters and meter readers.
+
+ This memo defines the SNMP management information for a Traffic Flow
+ Meter (TFM). It documents the earlier work of the Internet Accounting
+ Working Group, and is intended to provide a starting point for the
+ Realtime Traffic Flow Measurement Working Group.
+
+3.1 Scope of Definitions, Textual Conventions
+
+ All objects defined in this memo are registered in a single subtree
+ within the mib-2 namespace [1,2], and are for use in network devices
+ which may perform a PDU forwarding or monitoring function. For these
+ devices, the value of the ifSpecific variable in the MIB-II [1] has
+ the OBJECT IDENTIFIER value:
+
+ flowMIB OBJECT IDENTIFIER ::= mib-2 40
+
+ as defined below.
+
+ The RTFM Meter MIB was first produced and tested using SNMPv1. It
+ has been converted into SNMPv2 following the guidelines in RFC 1452
+ [5].
+
+
+
+
+
+
+
+
+Brownlee Experimental [Page 3]
+
+RFC 2064 Meter MIB January 1997
+
+
+3.2 Usage of the MIB variables
+
+ The MIB breaks into four parts - control, flows, rules and
+ conformance statements.
+
+ The rules implement the minumum set of packet-matching actions, as
+ set out in the "Traffic Flow Measurment: Architecture" document [9].
+ In addition they provide for BASIC-style subroutines, allowing a
+ network manager to dramatically reduce the number of rules required
+ to monitor a big network.
+
+ Traffic flows are identified by a set of attributes for each of its
+ end-points. Attributes include network addresses for each layer of
+ the network protocol stack, and 'subscriber ids,' which may be used
+ to identify an accountable entity for the flow.
+
+ The conformance statements are set out as defined in [4]. They
+ explain what must be implemented in a meter which claims to conform
+ to this MIB.
+
+ To retrieve flow data one could simply do a linear scan of the flow
+ table. This would certainly work, but would require a lot of
+ protocol exchanges. To reduce the overhead in retrieving flow data
+ the flow table uses a TimeFilter variable, defined as a Textual
+ Convention in the RMON2 MIB [10]. This, when used together with
+ SNMPv2's GetBulk request, allows a meter reader to scan the flow
+ table and upload a specified set of flow attributes for those rows
+ which have changed since the last reading.
+
+ As an alternative method of reading flow data, the MIB provides an
+ index into the flow table called flowColumnActivityTable. This is
+ (logically) a three-dimensional array, subscripted by flow attribute,
+ activity time and starting flow number. This allows a meter reader
+ to retrieve (in an opaque object) data for a column of the flow table
+ with a minimum of SNMP overhead. An attempt has been made to include
+ a full ASN.1 definition of the flowColumnActivityData object.
+
+ One aspect of data collection which needs emphasis is that all the
+ MIB variables are set up to allow multiple independent colletors to
+ work properly, i.e. the flow table indexes are stateless. An
+ alternative approach would have been to 'snapshot' the flow table,
+ which would mean that the meter readers would have to be
+ synchronized. The stateless approach does mean that two meter
+ readers will never return exactly the same set of traffic counts, but
+ over long periods (e.g. 15-minute collections over a day) the
+ discrepancies are acceptable. If one really needs a snapshot, this
+ can be achieved by switching to an identical rule set with a
+ different RuleSet number, hence asynchronous collections may be
+
+
+
+Brownlee Experimental [Page 4]
+
+RFC 2064 Meter MIB January 1997
+
+
+ regarded as a useful generalisation of synchronised ones.
+
+ The control variables are the minimum set required for a meter
+ reader. Their number has been whittled down as experience has been
+ gained with the MIB implementation. A few of them are 'general,'
+ i.e. they control the overall behaviour of the meter. These are set
+ by a single 'master' manager, and no other manager should attempt to
+ change their values. The decision as to which manager is the
+ 'master' must be made by the network operations personnel
+ responsible; this MIB does not attempt to provide any support for
+ interaction between managers.
+
+ There are three other groups of control groups, arranged into tables
+ in the same way as in the RMON MIB [10]. They are used as follows:
+
+ - RULE SET INFO: Before attempting to download a rule table a manager
+ must create a row in the flowRuleSetInfo with flowRuleInfoStatus
+ set to 'createAndWait.' When the rule set is ready the manager
+ must set RuleSetInfo to 'active,' indicating that the rule set is
+ ready for use.
+
+ - METER READER INFO: Any meter reader wishing to collect data
+ reliably for all flows should first create a row in the
+ flowReaderInfoTable with flowReaderStatus set to 'active.' It
+ should write that row's flowReaderLastTime object each time it
+ starts a collection pass through the flow table. The meter will
+ not recover a flow's memory until every meter reader holding a row
+ in this table has collected that flow's data.
+
+ - MANAGER INFO: Any manager wishing to download rule sets to the
+ meter must create a row in the flowManagerInfo table with
+ flowManagerStatus set to 'active.'. Once it has a table row, the
+ manager may set the control variables in its row so as to cause the
+ meter to run any valid rule set held by the meter.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brownlee Experimental [Page 5]
+
+RFC 2064 Meter MIB January 1997
+
+
+4 Definitions
+
+FLOW-METER-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, TimeTicks
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, RowStatus, TimeStamp
+ FROM SNMPv2-TC
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ mib-2, ifIndex
+ FROM RFC1213-MIB
+ OwnerString
+ FROM RMON-MIB;
+
+flowMIB MODULE-IDENTITY
+ LAST-UPDATED "9603080208Z"
+ ORGANIZATION "IETF Realtime Traffic Flow Measurement Working Group"
+ CONTACT-INFO
+ "Nevil Brownlee, The University of Auckland
+ Email: n.brownlee@auckland.ac.nz"
+ DESCRIPTION
+ "MIB for the RTFM Traffic Flow Meter."
+ ::= { mib-2 40 }
+
+
+flowControl OBJECT IDENTIFIER ::= { flowMIB 1 }
+
+flowData OBJECT IDENTIFIER ::= { flowMIB 2 }
+
+flowRules OBJECT IDENTIFIER ::= { flowMIB 3 }
+
+flowMIBConformance OBJECT IDENTIFIER ::= { flowMIB 4 }
+
+
+-- Textual Conventions
+
+TimeFilter ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Used as an index to a table. A TimeFilter variable allows
+ a GetNext or GetBulk request to find rows in a table for
+ which the TimeFilter index variable is greater than or equal
+ to a specified value. For example, a meter reader could
+ find all rows in the flow table which have been active at or
+ since a specified time.
+
+
+
+
+Brownlee Experimental [Page 6]
+
+RFC 2064 Meter MIB January 1997
+
+
+ More details on TimeFilter variables, their implementation
+ and use can be found in the RMON2 MIB [10]."
+ SYNTAX TimeTicks
+
+AddressType ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Indicates the type of an adjacent address or peer address.
+ The values used are from the 'Address Family Numbers' section
+ of the Assigned Numbers RFC [11]."
+ SYNTAX INTEGER {
+ ip(1),
+ nsap(3),
+ ieee802(6),
+ ipx(11),
+ appletalk(12),
+ decnet(13) }
+
+AdjacentAddress ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Specifies the value of an adjacent address for various
+ media. The values used for IEEE 802 media are from the
+ 'Network Management Parameters (ifType definitions)'
+ section of the Assigned Numbers RFC [11]. Address format
+ depends on the actual media, as follows:
+
+ Ethernet: ethernet(7)
+ 6-octet 802.3 MAC address in 'canonical' order
+
+ FDDI: fddi(15)
+ FddiMACLongAddress, i.e. a 6-octet MAC address
+ in 'canonical' order (defined in the FDDI MIB [12])
+
+ Token Ring: tokenring(9)
+ 6-octet 802.5 MAC address in 'canonical' order
+
+ PeerAddress: other(1)
+ If traffic is being metered inside a tunnel, its
+ adjacent addresses will be the peer addresses of hosts
+ at the ends of the tunnel
+ "
+ SYNTAX OCTET STRING (SIZE (6..20))
+
+PeerAddress ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Specifies the value of a peer address for various network
+
+
+
+Brownlee Experimental [Page 7]
+
+RFC 2064 Meter MIB January 1997
+
+
+ protocols. Address format depends on the actual protocol,
+ as follows:
+
+ IP: ip(1)
+ 4-octet IpAddress (defined in the SNMPv2 SMI [2])
+
+ CLNS: nsap(3)
+ NsapAddress (defined in the SNMPv2 SMI [2])
+
+ Novell: ipx(11)
+ 4-octet Network number,
+ 6-octet Host number (MAC address)
+
+ AppleTalk: appletalk(12)
+ 2-octet Network number (sixteen bits),
+ 1-octet Host number (eight bits)
+
+ DECnet: decnet(13)
+ 1-octet Area number (in low-order six bits),
+ 2-octet Host number (in low-order ten bits)
+ "
+ SYNTAX OCTET STRING (SIZE (3..20))
+
+TransportAddress ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Specifies the value of a transport address for various
+ network protocols. Format as follows:
+
+ IP:
+ 2-octet UDP or TCP port number
+
+ Other protocols:
+ 2-octet port number
+ "
+ SYNTAX OCTET STRING (SIZE (2))
+
+RuleAddress ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Specifies the value of an address. Is a superset of
+ AdjacentAddress, PeerAddress and TransportAddress."
+ SYNTAX OCTET STRING (SIZE (2..20))
+
+FlowAttributeNumber ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies an attribute within a flow data record."
+
+
+
+Brownlee Experimental [Page 8]
+
+RFC 2064 Meter MIB January 1997
+
+
+ SYNTAX INTEGER {
+ flowIndex(1),
+ flowStatus(2),
+ flowTimeMark(3),
+
+ sourceInterface(4),
+ sourceAdjacentType(5),
+ sourceAdjacentAddress(6),
+ sourceAdjacentMask(7),
+ sourcePeerType(8),
+ sourcePeerAddress(9),
+ sourcePeerMask(10),
+ sourceTransType(11),
+ sourceTransAddress(12),
+ sourceTransMask(13),
+
+ destInterface(14),
+ destAdjacentType(15),
+ destAdjacentAddress(16),
+ destAdjacentMask(17),
+ destPeerType(18),
+ destPeerAddress(19),
+ destPeerMask(20),
+ destTransType(21),
+ destTransAddress(22),
+ destTransMask(23),
+
+ pduScale(234),
+ octetScale(25),
+
+ ruleSet(26),
+ toOctets(27), -- Source-to-Dest
+ toPDUs(28),
+ fromOctets(29), -- Dest-to-Source
+ fromPDUs(30),
+ firstTime(31), -- Activity times
+ lastActiveTime(32),
+
+ sourceSubscriberID(33), -- Subscriber ID
+ destSubscriberID(34),
+ sessionID(35),
+
+ sourceClass(36), -- Computed attributes
+ destClass(37),
+ flowClass(38),
+ sourceKind(39),
+ destKind(40),
+ flowKind(41) }
+
+
+
+Brownlee Experimental [Page 9]
+
+RFC 2064 Meter MIB January 1997
+
+
+RuleAttributeNumber ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies an attribute which may be tested in
+ a rule. These include attributes whose values come directly
+ from the flow's packets and the five 'meter' variables used to
+ hold an AttributeValue. Attributes derived from the rules -
+ e.g. address masks - may not be tested."
+ SYNTAX INTEGER {
+ null(0),
+ sourceInterface(4), -- Source Address
+ sourceAdjacentType(5),
+ sourceAdjacentAddress(6),
+ sourcePeerType(8),
+ sourcePeerAddress(9),
+ sourceTransType(11),
+ sourceTransAddress(12),
+ destInterface(14), -- Dest Address
+ destAdjacentType(15),
+ destAdjacentAddress(16),
+ destPeerType(18),
+ destPeerAddress(19),
+ destTransType(21),
+ destTransAddress(22),
+ sourceSubscriberID(33), -- Subscriber ID
+ destSubscriberID(34),
+ sessionID(35),
+ v1(51), -- Meter variables
+ v2(52),
+ v3(53),
+ v4(54),
+ v5(55) }
+
+ActionNumber ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "Uniquely identifies the action of a rule, i.e. the Pattern
+ Matching Engine's opcode number. Details of the opcodes
+ are given in the 'Traffic Flow Measurement: Architecture'
+ document [9]."
+ SYNTAX INTEGER {
+ ignore(1),
+ fail(2),
+ count(3),
+ countPkt(4),
+ return(5),
+ gosub(6),
+ gosubAct(7),
+
+
+
+Brownlee Experimental [Page 10]
+
+RFC 2064 Meter MIB January 1997
+
+
+ assign(8),
+ assignAct(9),
+ goto(10),
+ gotoAct(11),
+ pushRuleTo(12),
+ pushRuleToAct(13),
+ pushPktTo(14),
+ pushPktToAct(15) }
+
+
+--
+-- Control Group: Rule Set Info Table
+--
+
+flowRuleSetInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowRuleSetInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An array of information about the rule sets held in the
+ meter. Rule set 1 is the meter default, used when the meter
+ starts up. It is built in to the meter; it may not be
+ changed."
+ ::= { flowControl 1 }
+
+flowRuleSetInfoEntry OBJECT-TYPE
+ SYNTAX FlowRuleSetInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a particular rule set."
+ INDEX { flowRuleInfoIndex }
+ ::= { flowRuleSetInfoTable 1 }
+
+FlowRuleSetInfoEntry ::= SEQUENCE {
+ flowRuleInfoIndex Integer32,
+ flowRuleInfoSize Integer32,
+ flowRuleInfoOwner OwnerString,
+ flowRuleInfoTimeStamp TimeStamp,
+ flowRuleInfoStatus RowStatus
+ }
+
+flowRuleInfoIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An index which selects an entry in the flowRuleSetInfoTable.
+
+
+
+Brownlee Experimental [Page 11]
+
+RFC 2064 Meter MIB January 1997
+
+
+ Each such entry contains control information for a particular
+ rule set which the meter may run."
+ ::= { flowRuleSetInfoEntry 1 }
+
+flowRuleInfoSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Number of rules in this rule set. Setting this variable will
+ cause the meter to allocate space for these rules."
+ ::= { flowRuleSetInfoEntry 2 }
+
+flowRuleInfoOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Identifies the manager which configured this rule set."
+ ::= { flowRuleSetInfoEntry 3 }
+
+flowRuleInfoTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Time this rule set was last changed."
+ ::= { flowRuleSetInfoEntry 4 }
+
+flowRuleInfoStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this rule set. If this object's value is
+ not active(1), the meter must not attempt to use this
+ rule set."
+ ::= { flowRuleSetInfoEntry 5 }
+
+--
+-- Control Group: Interface Info Table
+--
+
+flowInterfaceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+
+
+
+Brownlee Experimental [Page 12]
+
+RFC 2064 Meter MIB January 1997
+
+
+ "An array of information specific to each meter interface."
+ ::= { flowControl 2 }
+
+flowInterfaceEntry OBJECT-TYPE
+ SYNTAX FlowInterfaceEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a particular interface."
+ INDEX { ifIndex }
+ ::= { flowInterfaceTable 1 }
+
+FlowInterfaceEntry ::= SEQUENCE {
+ flowInterfaceRate Integer32,
+ flowInterfaceLostPackets Counter32
+ }
+
+flowInterfaceRate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The parameter N for statistical counting on this interface.
+ Set to N to count 1/Nth of the packets appearing at this
+ interface. A meter should choose its own algorithm to
+ introduce variance into the sampling so that exactly every Nth
+ packet is not counted. A sampling rate of 1 counts all
+ packets. A sampling rate of 0 results in the interface
+ being ignored by the meter."
+ ::= { flowInterfaceEntry 1 }
+
+flowInterfaceLostPackets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets the meter has lost for this interface.
+ Such losses may occur because the meter has been unable to
+ keep up with the traffic volume."
+ ::= { flowInterfaceEntry 2 }
+
+--
+-- Control Group: Meter Reader Info Table
+--
+
+-- Any meter reader wishing to collect data reliably for all flows
+-- should first create a row in this table. It should write that
+-- row's flowReaderLastTime object each time it starts a collection
+
+
+
+Brownlee Experimental [Page 13]
+
+RFC 2064 Meter MIB January 1997
+
+
+-- pass through the flow table.
+
+-- The meter will not recover a flow's memory until every meter reader
+-- holding a row in this table has collected that flow's data.
+
+-- If a meter reader does not create a row in this table, e.g. because
+-- it failed authentication in the meter's SNMP write community,
+-- collection can still proceed but the meter may not be able to
+-- recover inactive flows.
+
+flowReaderInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowReaderInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An array of information about meter readers which have
+ registered their intent to collect flow data from this meter."
+ ::= { flowControl 3 }
+
+flowReaderInfoEntry OBJECT-TYPE
+ SYNTAX FlowReaderInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a particular meter reader."
+ INDEX { flowReaderIndex }
+ ::= { flowReaderInfoTable 1 }
+
+FlowReaderInfoEntry ::= SEQUENCE {
+ flowReaderIndex Integer32,
+ flowReaderTimeout Integer32,
+ flowReaderOwner OwnerString,
+ flowReaderLastTime TimeStamp,
+ flowReaderPreviousTime TimeStamp,
+ flowReaderStatus RowStatus
+ }
+
+flowReaderIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Selects an entry from the array of meter reader info entries."
+ ::= { flowReaderInfoEntry 1 }
+
+flowReaderTimeout OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+
+
+
+Brownlee Experimental [Page 14]
+
+RFC 2064 Meter MIB January 1997
+
+
+ STATUS current
+ DESCRIPTION
+ "Specifies the maximum time (in seconds) between flow data
+ collections for this meter reader. If this time elapses
+ without a collection, the meter should assume that this meter
+ reader has stopped collecting, and delete this row from the
+ table."
+ ::= { flowReaderInfoEntry 2 }
+
+flowReaderOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Identifies the meter reader which created this row."
+ ::= { flowReaderInfoEntry 3 }
+
+flowReaderLastTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Time this meter reader began its most recent data collection.
+
+ This variable should be written by a meter reader as the first
+ step in reading flow data. The meter will set this LastTime
+ value to sysUptime and set its PreviousTime value (below) to
+ the old LastTime. This allows the meter to recover flows
+ which have been inactive since PreviousTime, for these have
+ been collected at least once.
+
+ If the meter fails to write flowLastReadTime, e.g. by
+ failing authentication in the meter's SNMP write community,
+ collection may still proceed but the meter may not be able to
+ recover inactive flows."
+ ::= { flowReaderInfoEntry 4 }
+
+flowReaderPreviousTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Time this meter reader began the collection before last."
+ ::= { flowReaderInfoEntry 5 }
+
+flowReaderStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+
+
+
+Brownlee Experimental [Page 15]
+
+RFC 2064 Meter MIB January 1997
+
+
+ STATUS current
+ DESCRIPTION
+ "The status of this meter reader."
+ ::= { flowReaderInfoEntry 6 }
+
+--
+-- Control Group: Manager Info Table
+--
+
+-- Any manager wishing to download rule sets to the meter must create
+-- a row in this table. Once it has a table row, the manager may set
+-- the control variables in its row so as to cause the meter to run
+-- any valid rule set held by the meter.
+
+flowManagerInfoTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowManagerInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An array of information about managers which have
+ registered their intent to run rule sets on this meter."
+ ::= { flowControl 4 }
+
+flowManagerInfoEntry OBJECT-TYPE
+ SYNTAX FlowManagerInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a particular meter reader."
+ INDEX { flowManagerIndex }
+ ::= { flowManagerInfoTable 1 }
+
+FlowManagerInfoEntry ::= SEQUENCE {
+ flowManagerIndex Integer32,
+ flowManagerCurrentRuleSet Integer32,
+ flowManagerStandbyRuleSet Integer32,
+ flowManagerHighWaterMark INTEGER,
+ flowManagerCounterWrap INTEGER,
+ flowManagerOwner OwnerString,
+ flowManagerTimeStamp TimeStamp,
+ flowManagerStatus RowStatus
+ }
+
+flowManagerIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+
+
+
+Brownlee Experimental [Page 16]
+
+RFC 2064 Meter MIB January 1997
+
+
+ "Selects an entry from the array of manager info entries."
+ ::= { flowManagerInfoEntry 1 }
+
+flowManagerCurrentRuleSet OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Index to the array of rule sets. Specifies which set of
+ rules is currently being used for accounting by this manager.
+ When the manager sets this variable the meter will close its
+ current rule set and start using the new one. Flows created
+ by the old rule set remain in memory, orphaned until their
+ data has been read. Specifying rule set 0 (the empty set)
+ stops flow measurement by this manager."
+ ::= { flowManagerInfoEntry 2 }
+
+flowManagerStandbyRuleSet OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Index to the array of rule sets. After reaching
+ HighWaterMark (see below) the manager may switch to using its
+ standby rule set. For this to be effective the manager should
+ have downloaded a standby rule set which uses a coarser
+ reporting granularity. The manager may also need to
+ decrease the meter reading interval so that the meter can
+ recover flows measured by its normal rule set."
+ DEFVAL { 0 } -- No standby
+ ::= { flowManagerInfoEntry 3 }
+
+flowManagerHighWaterMark OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A value expressed as a percentage, interpreted by the meter
+ as an indication of how full the flow table should be before
+ it should switch to the standby rule set (if one has been
+ specified) forthis manager. Values of 0% or 100% disable
+ the checking represented by this variable."
+ ::= { flowManagerInfoEntry 4 }
+
+flowManagerCounterWrap OBJECT-TYPE
+ SYNTAX INTEGER { wrap(1), scale(2) }
+ MAX-ACCESS read-create
+ STATUS current
+
+
+
+Brownlee Experimental [Page 17]
+
+RFC 2064 Meter MIB January 1997
+
+
+ DESCRIPTION
+ "Specifies whether PDU and octet counters should wrap when
+ they reach the top of their range (normal behaviour for
+ Counter32 objects), or whether their scale factors should
+ be used instead. The combination of counter and scale
+ factor allows counts to be returned as binary floating
+ point numbers, with 32-bit mantissas and 8-bit exponents."
+ DEFVAL { wrap }
+ ::= { flowManagerInfoEntry 5 }
+
+flowManagerOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Identifies the manager which created this row."
+ ::= { flowManagerInfoEntry 6 }
+
+flowManagerTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Time this row was last changed by its manager."
+ ::= { flowManagerInfoEntry 7 }
+
+flowManagerStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this manager."
+ ::= { flowManagerInfoEntry 8 }
+
+--
+-- Control Group: General Meter Control Variables
+--
+
+-- At present the meter only runs a single rule set - the 'current'
+-- one and has a single 'standby' rule set. In future it may be
+-- developed so as to run multiple rule sets simultaneously; that would
+-- require a more elaborate set of control variables to allow reliable
+-- operation.
+
+flowFloodMark OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+
+
+
+Brownlee Experimental [Page 18]
+
+RFC 2064 Meter MIB January 1997
+
+
+ DESCRIPTION
+ "A value expressed as a percentage, interpreted by the meter
+ as an indication of how full the flow table should be before
+ it should take some action to avoid running out of resources
+ to handle new flows. Values of 0% or 100% disable the
+ checking represented by this variable."
+ ::= { flowControl 5 }
+
+flowInactivityTimeout OBJECT-TYPE
+ SYNTAX Integer32 (1..3600)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The time in seconds since the last packet seen, after
+ which the flow may be terminated. Note that although a
+ flow may have been terminated, its data must be collected
+ before its memory can be recovered."
+ DEFVAL { 600 } -- 10 minutes
+ ::= { flowControl 6 }
+
+flowActiveFlows OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The numbers of flows which are currently in use, i.e. have
+ been active since the last collection."
+ ::= { flowControl 7 }
+
+flowMaxFlows OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of flows allowed in the meter's
+ flow table. At present this is determined when the meter
+ is first started up."
+ ::= { flowControl 8 }
+
+
+--
+-- The Flow Table
+--
+
+-- This is a table kept by a meter, with one flow data entry for every
+-- flow being measured. Each flow data entry stores the attribute
+-- values for a traffic flow. Details of flows and their attributes
+-- are given in the 'Traffic Flow Measurement: Architecture'
+
+
+
+Brownlee Experimental [Page 19]
+
+RFC 2064 Meter MIB January 1997
+
+
+-- document [9].
+
+-- From time to time a meter reader may sweep the flow table so as
+-- to read counts. This is most effectively achieved by using the
+-- TimeMark variable together with successive GetBulk requests to
+-- retrieve the values of the desired flow attribute variables.
+
+-- This scheme allows multiple meter readers to independently use the
+-- same meter; the meter readers do not have to be synchronised and
+-- they may use different collection intervals.
+
+flowDataTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowDataEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The list of all flows being measured."
+ ::= { flowData 1 }
+
+flowDataEntry OBJECT-TYPE
+ SYNTAX FlowDataEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The flow data record for a particular flow."
+ INDEX { flowDataTimeMark, flowDataIndex }
+ ::= { flowDataTable 1 }
+
+FlowDataEntry ::= SEQUENCE {
+ flowDataIndex Integer32,
+ flowDataTimeMark TimeFilter,
+ flowDataStatus INTEGER,
+
+ flowDataSourceInterface Integer32,
+ flowDataSourceAdjacentType AddressType,
+ flowDataSourceAdjacentAddress AdjacentAddress,
+ flowDataSourceAdjacentMask AdjacentAddress,
+ flowDataSourcePeerType AddressType,
+ flowDataSourcePeerAddress PeerAddress,
+ flowDataSourcePeerMask PeerAddress,
+ flowDataSourceTransType INTEGER,
+ flowDataSourceTransAddress TransportAddress,
+ flowDataSourceTransMask TransportAddress,
+
+ flowDataDestInterface Integer32,
+ flowDataDestAdjacentType AddressType,
+ flowDataDestAdjacentAddress AdjacentAddress,
+ flowDataDestAdjacentMask AdjacentAddress,
+
+
+
+Brownlee Experimental [Page 20]
+
+RFC 2064 Meter MIB January 1997
+
+
+ flowDataDestPeerType AddressType,
+ flowDataDestPeerAddress PeerAddress,
+ flowDataDestPeerMask PeerAddress,
+ flowDataDestTransType INTEGER,
+ flowDataDestTransAddress TransportAddress,
+ flowDataDestTransMask TransportAddress,
+
+ flowDataPDUScale INTEGER,
+ flowDataOctetScale INTEGER,
+
+ flowDataRuleSet INTEGER,
+
+ flowDataToOctets Counter32, -- Source->Dest
+ flowDataToPDUs Counter32,
+ flowDataFromOctets Counter32, -- Dest->Source
+ flowDataFromPDUs Counter32,
+ flowDataFirstTime TimeTicks, -- Activity times
+ flowDataLastActiveTime TimeTicks,
+
+ flowDataSourceSubscriberID OCTET STRING,
+ flowDataDestSubscriberID OCTET STRING,
+ flowDataSessionID OCTET STRING,
+
+ flowDataSourceClass INTEGER,
+ flowDataDestClass INTEGER,
+ flowDataClass INTEGER,
+ flowDataSourceKind INTEGER,
+ flowDataDestKind INTEGER,
+ flowDataKind INTEGER
+ }
+
+flowDataIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Value of this flow data record's index within the meter's
+ flow table."
+ ::= { flowDataEntry 1 }
+
+flowDataTimeMark OBJECT-TYPE
+ SYNTAX TimeFilter
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A TimeFilter for this entry. Allows GetNext and GetBulk
+ to find flow table rows which have changed since a specified
+ value of sysUptime."
+
+
+
+Brownlee Experimental [Page 21]
+
+RFC 2064 Meter MIB January 1997
+
+
+ ::= { flowDataEntry 2 }
+
+flowDataStatus OBJECT-TYPE
+ SYNTAX INTEGER { inactive(1), current(2), idle(3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Status of this flow data record."
+ ::= { flowDataEntry 3 }
+
+flowDataSourceInterface OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the interface associated with the source address
+ for this flow. It's value is one of those contained in the
+ ifIndex field of the meter's interfaces table."
+ ::= { flowDataEntry 4 }
+
+flowDataSourceAdjacentType OBJECT-TYPE
+ SYNTAX AddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Adjacent address type of the source for this flow. If
+ accounting is being performed at the network level the
+ adjacent address will probably be an 802 MAC address, and
+ the adjacent address type will indicate the medium type."
+ ::= { flowDataEntry 5 }
+
+flowDataSourceAdjacentAddress OBJECT-TYPE
+ SYNTAX AdjacentAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Address of the adjacent device on the path for the source
+ for this flow."
+ ::= { flowDataEntry 6 }
+
+flowDataSourceAdjacentMask OBJECT-TYPE
+ SYNTAX AdjacentAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+ comparing the adjacent source address for this flow."
+ ::= { flowDataEntry 7 }
+
+
+
+Brownlee Experimental [Page 22]
+
+RFC 2064 Meter MIB January 1997
+
+
+flowDataSourcePeerType OBJECT-TYPE
+ SYNTAX AddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peer address type of the source for this flow."
+ ::= { flowDataEntry 8 }
+
+flowDataSourcePeerAddress OBJECT-TYPE
+ SYNTAX PeerAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Address of the peer device for the source of this flow."
+ ::= { flowDataEntry 9 }
+
+flowDataSourcePeerMask OBJECT-TYPE
+ SYNTAX PeerAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+ comparing the source peer address for this flow."
+ ::= { flowDataEntry 10 }
+
+flowDataSourceTransType OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transport address type of the source for this flow. The
+ value of this attribute will depend on the peer address type."
+ ::= { flowDataEntry 11 }
+
+flowDataSourceTransAddress OBJECT-TYPE
+ SYNTAX TransportAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transport address for the source of this flow."
+ ::= { flowDataEntry 12 }
+
+flowDataSourceTransMask OBJECT-TYPE
+ SYNTAX TransportAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+
+
+
+Brownlee Experimental [Page 23]
+
+RFC 2064 Meter MIB January 1997
+
+
+ comparing the transport source address for this flow."
+ ::= { flowDataEntry 13 }
+
+flowDataDestInterface OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of the interface associated with the dest address for
+ this flow. This value is one of the values contained in the
+ ifIndex field of the interfaces table."
+ ::= { flowDataEntry 14 }
+
+flowDataDestAdjacentType OBJECT-TYPE
+ SYNTAX AddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Adjacent address type of the destination for this flow."
+ ::= { flowDataEntry 15 }
+
+flowDataDestAdjacentAddress OBJECT-TYPE
+ SYNTAX AdjacentAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Address of the adjacent device on the path for the
+ destination for this flow."
+ ::= { flowDataEntry 16 }
+
+flowDataDestAdjacentMask OBJECT-TYPE
+ SYNTAX AdjacentAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+ comparing the adjacent dest address for this flow."
+ ::= { flowDataEntry 17 }
+
+flowDataDestPeerType OBJECT-TYPE
+ SYNTAX AddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Peer address type of the destination for this flow."
+ ::= { flowDataEntry 18 }
+
+flowDataDestPeerAddress OBJECT-TYPE
+
+
+
+Brownlee Experimental [Page 24]
+
+RFC 2064 Meter MIB January 1997
+
+
+ SYNTAX PeerAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Address of the peer device for the destination of this flow."
+ ::= { flowDataEntry 19 }
+
+flowDataDestPeerMask OBJECT-TYPE
+ SYNTAX PeerAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+ comparing the dest peer type for this flow."
+ ::= { flowDataEntry 20 }
+
+flowDataDestTransType OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transport address type of the destination for this flow. The
+ value of this attribute will depend on the peer address type."
+ ::= { flowDataEntry 21 }
+
+flowDataDestTransAddress OBJECT-TYPE
+ SYNTAX TransportAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Transport address for the destination of this flow."
+ ::= { flowDataEntry 22 }
+
+flowDataDestTransMask OBJECT-TYPE
+ SYNTAX TransportAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "1-bits in this mask indicate which bits must match when
+ comparing the transport destination address for this flow."
+ ::= { flowDataEntry 23 }
+
+flowDataPDUScale OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The scale factor applied to this particular flow. Indicates
+
+
+
+Brownlee Experimental [Page 25]
+
+RFC 2064 Meter MIB January 1997
+
+
+ the number of bits the PDU counter values should be moved left
+ to obtain the actual values."
+ ::= { flowDataEntry 24 }
+
+flowDataOctetScale OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The scale factor applied to this particular flow. Indicates
+ the number of bits the octet counter values should be moved
+ left to obtain the actual values."
+ ::= { flowDataEntry 25 }
+
+flowDataRuleSet OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The RuleSet number of the rule set which created this flow."
+ ::= { flowDataEntry 26 }
+
+flowDataToOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The count of octets flowing from source to dest address and
+ being delivered to the protocol level being metered. In the
+ case of IP this would count the number of octets delivered to
+ the IP level."
+ ::= { flowDataEntry 27 }
+
+flowDataToPDUs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The count of protocol packets flowing from source to dest
+ address and being delivered to the protocol level being
+ metered. In the case of IP, for example, this would count the
+ IP packets delivered to the IP protocol level."
+ ::= { flowDataEntry 28 }
+
+flowDataFromOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Brownlee Experimental [Page 26]
+
+RFC 2064 Meter MIB January 1997
+
+
+ DESCRIPTION
+ "The count of octets flowing from dest to source address and
+ being delivered to the protocol level being metered."
+ ::= { flowDataEntry 29 }
+
+flowDataFromPDUs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The count of protocol packets flowing from dest to source
+ address and being delivered to the protocol level being
+ metered. In the case of IP, for example, this would count
+ the IP packets delivered to the IP protocol level."
+ ::= { flowDataEntry 30 }
+
+flowDataFirstTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which this flow was first entered in the table"
+ ::= { flowDataEntry 31 }
+
+flowDataLastActiveTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The last time this flow had activity, i.e. the time of
+ arrival of the most recent PDU belonging to this flow."
+ ::= { flowDataEntry 32 }
+
+flowDataSourceSubscriberID OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (4..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Subscriber ID associated with the source address for this
+ flow."
+ ::= { flowDataEntry 33 }
+
+flowDataDestSubscriberID OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (4..20))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Subscriber ID associated with the dest address for this
+
+
+
+Brownlee Experimental [Page 27]
+
+RFC 2064 Meter MIB January 1997
+
+
+ flow."
+ ::= { flowDataEntry 34 }
+
+flowDataSessionID OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (4..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Session ID for this flow. Such an ID might be allocated
+ by a network access server to distinguish a series of sessions
+ between the same pair of addresses, which would otherwise
+ appear to be parts of the same accounting flow."
+ ::= { flowDataEntry 35 }
+
+flowDataSourceClass OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Source class for this flow. Determined by the rules, set by
+ a PushRule action when this flow was entered in the table."
+ ::= { flowDataEntry 36 }
+
+flowDataDestClass OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Destination class for this flow. Determined by the rules, set
+ by a PushRule action when this flow was entered in the table."
+ ::= { flowDataEntry 37 }
+
+flowDataClass OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Class for this flow. Determined by the rules, set by a
+ PushRule action when this flow was entered in the table."
+ ::= { flowDataEntry 38 }
+
+flowDataSourceKind OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Source kind for this flow. Determined by the rules, set by
+ a PushRule action when this flow was entered in the table."
+
+
+
+Brownlee Experimental [Page 28]
+
+RFC 2064 Meter MIB January 1997
+
+
+ ::= { flowDataEntry 39 }
+
+flowDataDestKind OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Destination kind for this flow. Determined by the rules, set
+ by a PushRule action when this flow was entered in the table."
+ ::= { flowDataEntry 40 }
+
+flowDataKind OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Class for this flow. Determined by the rules, set by a
+ PushRule action when this flow was entered in the table."
+ ::= { flowDataEntry 41 }
+
+
+--
+-- The Activity Column Table
+--
+
+flowColumnActivityTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowColumnActivityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index into the Flow Table. Allows a meter reader to retrieve
+ a list containing the flow table indeces of flows which were
+ last active at or after a given time, together with the values
+ of a specified attribute for each such flow."
+ ::= { flowData 2 }
+
+flowColumnActivityEntry OBJECT-TYPE
+ SYNTAX FlowColumnActivityEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Column Activity Entry for a particular attribute,
+ activity time and flow."
+ INDEX { flowColumnActivityAttribute, flowColumnActivityTime,
+ flowColumnActivityIndex }
+ ::= { flowColumnActivityTable 1 }
+
+FlowColumnActivityEntry ::= SEQUENCE {
+
+
+
+Brownlee Experimental [Page 29]
+
+RFC 2064 Meter MIB January 1997
+
+
+ flowColumnActivityAttribute FlowAttributeNumber,
+ flowColumnActivityTime TimeFilter,
+ flowColumnActivityIndex Integer32,
+ flowColumnActivityData OCTET STRING
+ }
+
+flowColumnActivityAttribute OBJECT-TYPE
+ SYNTAX FlowAttributeNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Specifies the attribute for which values are required from
+ active flows."
+ ::= { flowColumnActivityEntry 1 }
+
+flowColumnActivityTime OBJECT-TYPE
+ SYNTAX TimeFilter
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable is a copy of flowDataLastActiveTime in the
+ flow data record identified by the flowColumnActivityIndex
+ value of this flowColumnActivityTable entry."
+ ::= { flowColumnActivityEntry 2 }
+
+flowColumnActivityIndex OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Index of a flow table entry which was active at or after
+ a specified flowColumnActivityTime."
+ ::= { flowColumnActivityEntry 3 }
+
+flowColumnActivityData OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (3..1000))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Collection of attribute data for flows active after
+ flowColumnActivityTime. Within the OCTET STRING is a
+ sequence of { flow index, attribute value } pairs, one for
+ each active flow. The end of the sequence is marked by a
+ flow index value of 0, indicating that there are no more
+ rows in this column.
+
+ The format of objects inside flowColumnFlowData is as follows.
+ All numbers are unsigned. Numbers and strings appear with
+
+
+
+Brownlee Experimental [Page 30]
+
+RFC 2064 Meter MIB January 1997
+
+
+ their high-order bytes leading. Numbers are fixed size, as
+ specified by their SYNTAX in the flow table (above), i.e. one
+ octet for flowAddressType and small constants, and four octets
+ for Counter and Timeticks. Strings are variable-length, with
+ the length given in a single leading octet.
+
+ The following is an attempt at an ASN.1 definition of
+ flowColumnActivityData:
+
+ flowColumnActivityData ::= SEQUENCE flowRowItemEntry
+ flowRowItemEntry ::= SEQUENCE {
+ flowRowNumber INTEGER (1..65535),
+ -- 0 indicates the end of this column
+ flowDataValue flowDataType -- Choice depends on attribute
+ }
+ flowDataType ::= CHOICE {
+ flowByteValue INTEGER (1..255),
+ flowShortValue INTEGER (1..65535),
+ flowLongValue Integer32,
+ flowStringValue OCTET STRING -- Length (n) in first byte,
+ -- n+1 bytes total length, trailing zeroes truncated
+ }"
+ ::= { flowColumnActivityEntry 4 }
+
+
+--
+-- The Rule Table
+--
+
+-- This is an array of rule tables; the one in use is selected by
+-- CurrentRuleSet. To change the rule set the manager chooses a set
+-- number which is not in use, downloads the new rule set there, then
+-- writes the new set number into CurrentRuleSet. Rule set 1 is the
+-- default rule set, used by the meter on start-up. Several rule sets
+-- can be held in a meter so that the manager can change the rules
+-- easily, for example with time of day. Note that a manager may
+-- not change the default rule set, nor the rules in its current rule
+-- set! See the 'Traffic Flow Measurement: Architecture' document [9]
+-- for details of rules and how they are used.
+
+flowRuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FlowRuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains all the rule sets which may be used by the meter."
+ ::= { flowRules 1 }
+
+
+
+
+Brownlee Experimental [Page 31]
+
+RFC 2064 Meter MIB January 1997
+
+
+flowRuleEntry OBJECT-TYPE
+ SYNTAX FlowRuleEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The rule record itself."
+ INDEX { flowRuleSet, flowRuleIndex }
+ ::= { flowRuleTable 1 }
+
+FlowRuleEntry ::= SEQUENCE {
+ flowRuleSet INTEGER,
+ flowRuleIndex INTEGER,
+ flowRuleSelector RuleAttributeNumber,
+ flowRuleMask RuleAddress,
+ flowRuleMatchedValue RuleAddress,
+ flowRuleAction ActionNumber,
+ flowRuleParameter Integer32
+ }
+
+flowRuleSet OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Selects a rule set from the array of rule sets."
+ ::= { flowRuleEntry 1 }
+
+flowRuleIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index into the Rule table. N.B: These values will
+ often be consecutive, given the fall-through semantics of
+ processing the table."
+ ::= { flowRuleEntry 2 }
+
+flowRuleSelector OBJECT-TYPE
+ SYNTAX RuleAttributeNumber
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Indicates the attribute to be matched.
+
+ null(0) is a special case; null rules always succeed.
+
+ v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
+ variables, each of which can hold the name (i.e. selector
+
+
+
+Brownlee Experimental [Page 32]
+
+RFC 2064 Meter MIB January 1997
+
+
+ value) of an address attribute. When one of these is used
+ as a selector, its value specifies the attribute to be
+ tested. Variable values are set by an Assign action."
+ ::= { flowRuleEntry 3 }
+
+flowRuleMask OBJECT-TYPE
+ SYNTAX RuleAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The initial mask used to compute the desired value. If the
+ mask is zero the rule's test will always succeed."
+ ::= { flowRuleEntry 4 }
+
+flowRuleMatchedValue OBJECT-TYPE
+ SYNTAX RuleAddress
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The resulting value to be matched for equality.
+ Specifically, if the attribute chosen by the flowRuleSelector
+ logically ANDed with the mask specified by the flowRuleMask
+ equals the value specified in the flowRuleMatchedValue, then
+ continue processing the table entry based on the action
+ specified by the flowRuleAction entry. Otherwise, proceed to
+ the next entry in the rule table."
+ ::= { flowRuleEntry 5 }
+
+flowRuleAction OBJECT-TYPE
+ SYNTAX ActionNumber
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The action to be taken if this rule's test succeeds, or if
+ the meter's 'test' flag is off. Actions are opcodes for the
+ meter's Packet Matching Engine; details are given in the
+ 'Traffic Flow Measurement: Architecture' document [9]."
+ ::= { flowRuleEntry 6 }
+
+flowRuleParameter OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A parameter value providing extra information for the
+ rule's action."
+ ::= { flowRuleEntry 7 }
+
+
+
+
+Brownlee Experimental [Page 33]
+
+RFC 2064 Meter MIB January 1997
+
+
+--
+-- Traffic Flow Meter conformance statement
+--
+
+flowMIBCompliances
+ OBJECT IDENTIFIER ::= { flowMIBConformance 1 }
+
+flowMIBGroups
+ OBJECT IDENTIFIER ::= { flowMIBConformance 2 }
+
+flowControlGroup OBJECT-GROUP
+ OBJECTS {
+ flowRuleInfoSize, flowRuleInfoOwner,
+ flowRuleInfoTimeStamp, flowRuleInfoStatus,
+ flowInterfaceRate,
+ flowInterfaceLostPackets,
+ flowReaderTimeout, flowReaderOwner,
+ flowReaderLastTime, flowReaderPreviousTime,
+ flowReaderStatus,
+ flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
+ flowManagerHighWaterMark,
+ flowManagerOwner, flowManagerTimeStamp,
+ flowManagerStatus,
+ flowFloodMark,
+ flowInactivityTimeout,
+ flowActiveFlows,
+ flowMaxFlows }
+ STATUS current
+ DESCRIPTION
+ "The control group defines objects which are used to control
+ an accounting meter."
+ ::= {flowMIBGroups 1 }
+
+flowDataTableGroup OBJECT-GROUP
+ OBJECTS {
+ flowDataIndex,
+ flowDataStatus,
+ flowDataSourceInterface,
+ flowDataSourceAdjacentType,
+ flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask,
+ flowDataSourcePeerType,
+ flowDataSourcePeerAddress, flowDataSourcePeerMask,
+ flowDataSourceTransType,
+ flowDataSourceTransAddress, flowDataSourceTransMask,
+ flowDataDestInterface,
+ flowDataDestAdjacentType,
+ flowDataDestAdjacentAddress, flowDataDestAdjacentMask,
+ flowDataDestPeerType,
+
+
+
+Brownlee Experimental [Page 34]
+
+RFC 2064 Meter MIB January 1997
+
+
+ flowDataDestPeerAddress, flowDataDestPeerMask,
+ flowDataDestTransType,
+ flowDataDestTransAddress, flowDataDestTransMask,
+ flowDataRuleSet,
+ flowDataToOctets, flowDataToPDUs,
+ flowDataFromOctets, flowDataFromPDUs,
+ flowDataFirstTime, flowDataLastActiveTime,
+ flowDataSourceClass, flowDataDestClass, flowDataClass,
+ flowDataSourceKind, flowDataDestKind, flowDataKind
+ }
+ STATUS current
+ DESCRIPTION
+ "The flow table group defines objects which provide the
+ structure for the rule table, including the creation time
+ and activity time indexes into it. In addition it defines
+ objects which provide a base set of flow attributes for the
+ adjacent, peer and transport layers, together with a flow's
+ counters and times. Finally it defines a flow's class and
+ kind attributes, which are set by rule actions."
+ ::= {flowMIBGroups 2 }
+
+flowDataScaleGroup OBJECT-GROUP
+ OBJECTS {
+ flowManagerCounterWrap,
+ flowDataPDUScale, flowDataOctetScale
+ }
+ STATUS current
+ DESCRIPTION
+ "The flow scale group defines objects which specify scale
+ factors for counters."
+ ::= {flowMIBGroups 3 }
+
+flowDataSubscriberGroup OBJECT-GROUP
+ OBJECTS {
+ flowDataSourceSubscriberID, flowDataDestSubscriberID,
+ flowDataSessionID
+ }
+ STATUS current
+ DESCRIPTION
+ "The flow subscriber group defines objects which may be used
+ to identify the end point(s) of a flow."
+ ::= {flowMIBGroups 4 }
+
+flowDataColumnTableGroup OBJECT-GROUP
+ OBJECTS {
+ flowColumnActivityAttribute,
+ flowColumnActivityTime,
+ flowColumnActivityIndex,
+
+
+
+Brownlee Experimental [Page 35]
+
+RFC 2064 Meter MIB January 1997
+
+
+ flowColumnActivityData
+ }
+ STATUS current
+ DESCRIPTION
+ "The flow column table group defines objects which can be used
+ to collect part of a column of attribute values from the flow
+ table."
+ ::= {flowMIBGroups 5 }
+
+flowRuleTableGroup OBJECT-GROUP
+ OBJECTS {
+ flowRuleSelector,
+ flowRuleMask, flowRuleMatchedValue,
+ flowRuleAction, flowRuleParameter
+ }
+ STATUS current
+ DESCRIPTION
+ "The rule table group defines objects which hold the set(s)
+ of rules specifying which traffic flows are to be accounted
+ for."
+ ::= {flowMIBGroups 6 }
+
+flowMIBCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for a Traffic Flow Meter."
+ MODULE
+ MANDATORY-GROUPS {
+ flowControlGroup,
+ flowDataTableGroup,
+ flowRuleTableGroup
+ }
+ ::= { flowMIBCompliances 1 }
+
+END
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brownlee Experimental [Page 36]
+
+RFC 2064 Meter MIB January 1997
+
+
+5 Acknowledgements
+
+ This document was initially produced under the auspices of the IETF's
+ Accounting Working Group with assistance from SNMP and SAAG working
+ groups. Particular thanks are due to Jim Barnes, Sig Handelman and
+ Stephen Stibler for their support and their assistance with checking
+ the MIB.
+
+6 References
+
+ [1] McCloghrie, K., and M. Rose, Editors, "Management Information
+ Base for Network Management of TCP/IP-based internets," STD 17, RFC
+ 1213, Performance Systems International, March 1991.
+
+ [2] Case J., McCloghrie K., Rose M., and S. Waldbusser, "Structure of
+ Management Information for version 2 of the Simple Network
+ Managemenet Protocol," RFC 1902, SNMP Research Inc., Hughes LAN
+ Systems, Dover Beach Consulting, Carnegie Mellon University, April
+ 1993.
+
+ [3] Case J., McCloghrie, K., Rose, M., and S. Waldbusser, "Textual
+ Conventions for version 2 of the Simple Network Managemenet Protocol
+ SNMPv2", RFC 1903, SNMP Research Inc., Hughes LAN Systems, Dover
+ Beach Consulting, Carnegie Mellon University, April 1993.
+
+ [4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
+ "Conformance Statements for version 2 of the Simple Network
+ Managemenet Protocol (SNMPv2)," RFC 1904, SNMP Research Inc., Hughes
+ LAN Systems, Dover Beach Consulting, Carnegie Mellon University,
+ April 1993.
+
+ [5] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
+ "Coexistence between version 1 and version 2 of the Internet-standard
+ Network Management Framework," RFC 1908, SNMP Research Inc., Hughes
+ LAN Systems, Dover Beach Consulting, Carnegie Mellon University,
+ April 1993.
+
+ [6] Information processing systems - Open Systems Interconnection -
+ Specification of Abstract Syntax Notation One (ASN.1), International
+ Organization for Standardization, International Standard 8824,
+ December 1987.
+
+ [7] Information processing systems - Open Systems Interconnection -
+ Specification of Basic Encoding Rules for Abstract Notation One
+ (ASN.1), International Organization for Standardization,
+ International Standard 8825, December 1987.
+
+
+
+
+
+Brownlee Experimental [Page 37]
+
+RFC 2064 Meter MIB January 1997
+
+
+ [8] Mills, C., Hirsch, G. and G. Ruth, "Internet Accounting
+ Background," RFC 1272, Bolt Beranek and Newman Inc., Meridian
+ Technology Corporation, November 1991.
+
+ [9] Brownlee, N., Mills, C., and G. Ruth, "Traffic Flow Measurement:
+ Architecture", RFC 2063, The University of Auckland, Bolt Beranek and
+ Newman Inc., GTE Laboratories, Inc, January 1997.
+
+ [10] Waldbusser, S., "Remote Network Monitoring Management
+ Information Base, Version 2," Work in Progress.
+
+ [11] Reynolds, J., and J, Postel, "Assigned Numbers," STD 2, RFC
+ 1700, ISI, October 1994.
+
+ [12] Case, J., "FDDI Management Information Base," RFC 1285, SNMP
+ Research Incorporated, January 1992.
+
+7 Security Considerations
+
+ Security issues are not discussed in this document.
+
+8 Author's Address
+
+ Nevil Brownlee
+ Information Technology Systems & Services
+ The University of Auckland
+
+ Phone: +64 9 373 7599 x8941
+ EMail: n.brownlee @auckland.ac.nz
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brownlee Experimental [Page 38]
+