+Network Working Group John M. McQuillan
+RFC # 395 Bolt Beranek and Newman Inc.
+NIC # 11587 3 October 1972
+Categories: Updates:
+Obsoletes:
+
+ SWITCH SETTINGS ON IMPS AND TIPS
+ --------------------------------
+
+This note provides a description of the switches on the front panel of
+IMPs and TIPs that are important to the correct operation of the
+network software. We have had some difficulty in the past when
+certain of these switches were set incorrectly, This RFC will be
+updated as necessary, to notify site personnel of changes to the
+settings.
+
+A. 516 IMPs
+ --------
+The IMP at your site is a model 516 if it has a gray cabinet and two
+rows of indicator lights on the front panel. The correct switch
+settings are:
+
+ 1. Sense switches 1,2,3 and 4: OFF (DOWN)
+ 2. PFI/PFH: PFI (UP)
+ 3. HALT INH: OFF (DOWN)
+ 4. W.D.T.: OFF (DOWN)
+ 5. AUTO RSTRT: ON (UP)
+ 6. MEMORY PRTCT: OFF (DOWN)
+
+B. 316 IMPs and TIPs
+ -----------------
+The IMP at your site is a model 316 if it is a TIP or if it is in a
+black cabinet and has one row of indicator lights on the front panel.
+
+ 1. Sense switches 1,2,3,4 OFF (top half depressed)
+
+Site personnel are requested to keep a copy of this RFC near the IMP
+and to check the switch settings at their IMP. In addition, the
+Honeywell field engineers who perform preventive maintenance have been
+requested to use this note as a checklist.
+
+
+ [ This RFC was put into machine readable form for entry ]
+ [ into the online RFC archives by BBN Corp. under the ]
+ [ direction of Alex McKenzie. 1/97 ]
+
+
+
+
+
+
+ [Page 1]
+