summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc4295.txt
diff options
context:
space:
mode:
Diffstat (limited to 'doc/rfc/rfc4295.txt')
-rw-r--r--doc/rfc/rfc4295.txt6107
1 files changed, 6107 insertions, 0 deletions
diff --git a/doc/rfc/rfc4295.txt b/doc/rfc/rfc4295.txt
new file mode 100644
index 0000000..9a942c8
--- /dev/null
+++ b/doc/rfc/rfc4295.txt
@@ -0,0 +1,6107 @@
+
+
+
+
+
+
+Network Working Group G. Keeni
+Request for Comments: 4295 Cyber Solutions Inc.
+Category: Standards Track K. Koide
+ Tohoku University
+ K. Nagami
+ INTEC NetCore Inc.
+ S. Gundavelli
+ Cisco Systems Inc.
+ April 2006
+
+
+ Mobile IPv6 Management Information Base
+
+Status of This Memo
+
+ This document specifies an Internet standards track protocol for the
+ Internet community, and requests discussion and suggestions for
+ improvements. Please refer to the current edition of the "Internet
+ Official Protocol Standards" (STD 1) for the standardization state
+ and status of this protocol. Distribution of this memo is unlimited.
+
+Copyright Notice
+
+ Copyright (C) The Internet Society (2006).
+
+Abstract
+
+ This memo defines a portion of the Management Information Base (MIB),
+ the Mobile-IPv6 MIB, for use with network management protocols in the
+ Internet community. In particular, the Mobile-IPv6 MIB will be used
+ to monitor and control the mobile node, home agent, and correspondent
+ node functions of a Mobile IPv6 (MIPv6) entity.
+
+Table of Contents
+
+ 1. The Internet-Standard Management Framework ......................2
+ 2. Overview ........................................................2
+ 2.1. The Mobile IPv6 Protocol Entities ..........................2
+ 2.2. Terminology ................................................3
+ 3. Mobile IPv6 Monitoring and Control Requirements .................3
+ 4. MIB Design ......................................................4
+ 5. The Mobile-IPv6 MIB .............................................6
+ 6. Security Considerations .......................................104
+ 7. IANA Considerations ...........................................106
+ 8. References ....................................................106
+ 8.1. Normative References .....................................106
+ 8.2. Informative References ...................................107
+ 9. Acknowledgements ..............................................107
+
+
+
+Keeni, et al. Standards Track [Page 1]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+1. The Internet-Standard Management Framework
+
+ For a detailed overview of the documents that describe the current
+ Internet-Standard Management Framework, please refer to section 7 of
+ RFC 3410 [RFC3410].
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. MIB objects are generally
+ accessed through the Simple Network Management Protocol (SNMP).
+
+ Objects in the MIB are defined using the mechanisms defined in the
+ Structure of Management Information (SMI). This memo specifies a MIB
+ module that is compliant to the SMIv2, which is described in STD 58,
+ RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
+ [RFC2580].
+
+2. Overview
+
+2.1. The Mobile IPv6 Protocol Entities
+
+ Mobile IPv6 (MIPv6) [RFC3775] specifies a protocol that allows nodes
+ to remain reachable while moving around in the IPv6 Internet. An
+ entity that implements the MIPv6 protocol is a MIPv6 entity. There
+ are three types of entities envisaged by the MIPv6 protocol.
+
+ mobile node (MN): A node that can change its point of attachment
+ from one link to another, while still being reachable via its home
+ address.
+
+ correspondent node (CN): A peer node with which a mobile node is
+ communicating. The correspondent node may be either mobile or
+ stationary. (Note that a correspondent node does not necessarily
+ require MIPv6 support.)
+
+ home agent (HA): A router on a mobile node's home link with which
+ the mobile node has registered its current care-of address. While
+ the mobile node is away from home, the home agent intercepts
+ packets on the home link destined to the mobile node's home
+ address, encapsulates them, and routes them to the mobile node's
+ registered care-of address.
+
+ This document defines a set of managed objects (MOs) that can be used
+ to monitor and control MIPv6 entities.
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 2]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+2.2. Terminology
+
+ The terminology used in this document is consistent with the
+ definitions used in Mobile IPv6 protocol specification [RFC3775].
+
+ The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
+ "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
+ "OPTIONAL" in this document are to be interpreted as described in
+ BCP 14, RFC 2119 [RFC2119].
+
+3. Mobile IPv6 Monitoring and Control Requirements
+
+ For managing a MIPv6 entity it is necessary to monitor
+ the following:
+
+ o capabilities of MIPv6 entities
+ o traffic due to MIPv6
+ o binding-related statistics (at home agent, correspondent
+ node, and mobile node)
+ o binding details (at home agent and correspondent node)
+ o history of Binding Updates (at home agent, correspondent
+ node, and mobile node)
+
+ The MIPv6 protocol document stipulates that several MIPv6-related
+ parameters should be manually configurable. The MIPv6 MIB should
+ define managed objects that can be used to configure the related
+ parameters, for example:
+
+ o the preference value the home agent will use in Router
+ Advertisements;
+ o the lifetime value the home agent will use in Router
+ Advertisements;
+ o whether a home agent will send ICMP Mobile Prefix
+ Advertisements to mobile nodes;
+ o whether a home agent will respond to ICMP Mobile Prefix
+ Solicitation messages from mobile nodes; and
+ o whether a home agent will process multicast group membership
+ control messages from mobile nodes.
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 3]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+4. MIB Design
+
+ The basic principle has been to keep the MIB as simple as possible
+ and at the same time to make it effective enough so that the
+ essential needs of monitoring and control are met. It is envisaged
+ that wherever possible existing MIBs will be used (e.g., IPSec MIB,
+ Neighbor Discovery MIB, Tunnel MIB [RFC4087]) for monitor and control
+ of MIPv6 entities.
+
+ It is assumed that the Mobile IPv6 Management Information Base
+ (MOBILEIPV6-MIB) will always be implemented in conjunction with the
+ IPv6-capable version of the IP-MIB [RFC4293]. The MOBILEIPV6-MIB
+ uses the textual conventions defined in the INET-ADDRESS-MIB
+ [RFC4001].
+
+ The Mobile-IPv6 MIB is composed of the following groups of
+ definitions:
+
+ - mip6Core: a generic group containing objects that are
+ common to all the Mobile IPv6 entities.
+ - mip6Ha: this group models the home agent service. It is
+ composed of objects specific to the services and associated
+ advertisement parameters offered by the home agent on each
+ of its links. It also contains objects pertaining to the
+ maintenance of the home agent list on each of the links on
+ which the service is offered.
+ - mip6Mn: this group models the mobile node service. It is
+ composed of objects specific to the Dynamic Home Agent
+ discovery function and related parameters. It also contains
+ objects that record the movement of the mobile node.
+ - mip6Cn: models the correspondent node and is primarily
+ scoped to its participation in the Return Routability
+ procedure for achieving Route Optimization triggered by
+ the mobile node.
+ - mip6Notifications: defines the set of notifications that
+ will be used to asynchronously monitor the Mobile IPv6
+ entities.
+
+ The tables contained in the above groups are as follows:
+
+ mip6BindingCacheTable : models the binding cache on the home
+ agent and correspondent node. It
+ contains details of the Binding Update
+ requests that have been received and
+ accepted.
+ mip6BindingHistoryTable : tracks the history of the binding
+ cache.
+ mip6NodeTrafficTable : the mobile node-wise traffic counters.
+
+
+
+Keeni, et al. Standards Track [Page 4]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnHomeAddressTable : contains all the home addresses
+ pertaining to the mobile node and
+ the corresponding registration status.
+ mip6MnBLTable : models the Binding Update List on the
+ mobile node. It contains information
+ about the registration requests sent
+ by the mobile node and the
+ corresponding results.
+ mip6CnCounterTable : contains the mobile node-wise
+ registration statistics.
+ mip6HaConfTable : contains the configurable
+ advertisement parameters for all the
+ interfaces on which the home agent
+ service is advertised.
+ mip6HaCounterTable : contains registration statistics
+ for all mobile nodes registered
+ with the home agent.
+ mip6HaListTable : contains the list of all routers
+ that are acting as home agents on
+ each of the interfaces on which
+ the home agent service is offered
+ by this router.
+ mip6HaGlAddrTable : contains the global addresses of
+ the home agents.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 5]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+5. The Mobile-IPv6 MIB.
+
+ MOBILEIPV6-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ MODULE-IDENTITY, mib-2, Unsigned32, Integer32, Counter32,
+ Gauge32, Counter64,
+ OBJECT-TYPE, NOTIFICATION-TYPE
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION,
+ TruthValue, DateAndTime, TimeStamp
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ InetAddressType, InetAddress
+ FROM INET-ADDRESS-MIB
+ ipv6InterfaceIfIndex
+ FROM IP-MIB
+ ;
+
+ mip6MIB MODULE-IDENTITY
+ LAST-UPDATED "200602010000Z" -- 1st February 2006
+ ORGANIZATION "IETF mip6 Working Group"
+ CONTACT-INFO
+ " Glenn Mansfield Keeni
+ Postal: Cyber Solutions Inc.
+ 6-6-3, Minami Yoshinari
+ Aoba-ku, Sendai, Japan 989-3204.
+ Tel: +81-22-303-4012
+ Fax: +81-22-303-4015
+ E-mail: glenn@cysols.com
+
+ Kenichi Nagami
+ Postal: INTEC NetCore Inc.
+ 1-3-3, Shin-suna
+ Koto-ku, Tokyo, 135-0075
+ Japan
+
+ Tel: +81-3-5665-5069
+ E-mail: nagami@inetcore.com
+
+ Kazuhide Koide
+ Postal: Tohoku University
+ 2-1-1, Katahira
+ Aoba-ku, Sendai, 980-8577
+ Japan
+
+ Tel: +81-22-217-5454
+ E-mail: koide@shiratori.riec.tohoku.ac.jp
+
+
+
+Keeni, et al. Standards Track [Page 6]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+
+ Sri Gundavelli
+ Postal: Cisco Systems
+ 170 W.Tasman Drive,
+ San Jose, CA 95134
+ USA
+
+ Tel: +1-408-527-6109
+ E-mail: sgundave@cisco.com
+
+ Support Group E-mail: mip6@ietf.org"
+
+ DESCRIPTION
+ "The MIB module for monitoring Mobile-IPv6
+ entities.
+
+ Copyright (C) The Internet Society 2006. This
+ version of this MIB module is part of RFC 4295;
+ see the RFC itself for full legal notices.
+ "
+
+ REVISION "200602010000Z" -- 1st February 2006
+ DESCRIPTION "Initial version, published as RFC 4295."
+
+ ::= { mib-2 133 }
+
+
+ -- The major groups
+
+ mip6Notifications OBJECT IDENTIFIER ::= { mip6MIB 0 }
+ mip6Objects OBJECT IDENTIFIER ::= { mip6MIB 1 }
+ mip6Conformance OBJECT IDENTIFIER ::= { mip6MIB 2 }
+ mip6Core OBJECT IDENTIFIER ::= { mip6Objects 1 }
+ mip6Mn OBJECT IDENTIFIER ::= { mip6Objects 2 }
+ mip6Cn OBJECT IDENTIFIER ::= { mip6Objects 3 }
+ mip6Ha OBJECT IDENTIFIER ::= { mip6Objects 4 }
+
+ -- The sub groups
+
+ mip6System OBJECT IDENTIFIER ::= { mip6Core 1 }
+ mip6Bindings OBJECT IDENTIFIER ::= { mip6Core 2 }
+ mip6Stats OBJECT IDENTIFIER ::= { mip6Core 3 }
+
+ mip6MnSystem OBJECT IDENTIFIER ::= { mip6Mn 1 }
+ mip6MnConf OBJECT IDENTIFIER ::= { mip6Mn 2 }
+ mip6MnRegistration OBJECT IDENTIFIER ::= { mip6Mn 3 }
+
+ mip6CnSystem OBJECT IDENTIFIER ::= { mip6Cn 1 }
+
+
+
+Keeni, et al. Standards Track [Page 7]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnStats OBJECT IDENTIFIER ::= { mip6Cn 2 }
+
+ mip6HaAdvertisement OBJECT IDENTIFIER ::= { mip6Ha 1 }
+ mip6HaStats OBJECT IDENTIFIER ::= { mip6Ha 2 }
+
+
+
+ -- Textual Conventions
+ Mip6BURequestRejectionCode ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The value of the status field in the Binding
+ Acknowledgment message when the Binding Update
+ was rejected.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8"
+ SYNTAX INTEGER {
+ reasonUnspecified (1), --(Code 128)
+ admProhibited (2), --(Code 129)
+ insufficientResource (3), --(Code 130)
+ homeRegistrationNotSupported (4), --(Code 131)
+ notHomeSubnet (5), --(Code 132)
+ notHomeAgentForThisMobileNode (6), --(Code 133)
+ duplicateAddressDetectionFailed (7), --(Code 134)
+ sequenceNumberOutOfWindow (8), --(Code 135)
+ expiredHomeNonceIndex (9), --(Code 136)
+ expiredCareofNonceIndex (10), --(Code 137)
+ expiredNonces (11), --(Code 138)
+ registrationTypeChangeDisallowed(12) --(Code 139)
+ }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 8]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6Capabilities OBJECT-TYPE
+ SYNTAX BITS {
+ mobileNode (0),
+ homeAgent (1),
+ correspondentNode (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the Mobile IPv6 functions that
+ are supported by this managed entity. Multiple
+ Mobile IPv6 functions may be supported by a single
+ entity.
+ "
+ REFERENCE
+ "RFC 3775 : Section 3.2, 4.1"
+ ::= { mip6System 1 }
+
+ mip6Status OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object indicates whether the Mobile IPv6
+ function is enabled for the managed entity. If it
+ is enabled, the agent discovery and registration
+ functions will be operational.
+ Changing the status from enabled(1) to disabled(2)
+ will terminate the agent discovery and registration
+ functions. On the other hand, changing the status
+ from disabled(2) to enabled(1) will start the agent
+ discovery and registration functions.
+
+ The value of this object SHOULD remain unchanged
+ across reboots of the managed entity.
+ "
+ ::= { mip6System 2 }
+
+
+ -- mip6BindingCache
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 9]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingCacheTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6BindingCacheEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table models the Binding Cache on the
+ managed entity. The cache is maintained by home
+ agents and correspondent nodes. It contains
+ both correspondent registration entries and home
+ registration entries.
+
+ Entries in this table are not required to survive
+ a reboot of the managed entity.
+ "
+ REFERENCE
+ "RFC 3775 : Section 4.5, 9.1, 10.1"
+ ::= { mip6Bindings 1 }
+
+ mip6BindingCacheEntry OBJECT-TYPE
+ SYNTAX Mip6BindingCacheEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This entry represents a conceptual row in the
+ binding cache table. It represents a single Binding
+ Update.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6BindingHomeAddress
+ exceeds 113, then OIDs of column
+ instances in this row will have more than 128
+ sub-identifiers and cannot be accessed using
+ SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6BindingHomeAddressType, mip6BindingHomeAddress }
+ ::= { mip6BindingCacheTable 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 10]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ Mip6BindingCacheEntry ::=
+ SEQUENCE {
+ mip6BindingHomeAddressType InetAddressType,
+ mip6BindingHomeAddress InetAddress,
+ mip6BindingCOAType InetAddressType,
+ mip6BindingCOA InetAddress,
+ mip6BindingTimeRegistered DateAndTime,
+ mip6BindingTimeGranted Gauge32,
+ mip6BindingTimeRemaining Gauge32,
+ mip6BindingHomeRegn TruthValue,
+ mip6BindingMaxSeq Unsigned32,
+ mip6BindingUsageTS DateAndTime,
+ mip6BindingUsageCount Gauge32,
+ mip6BindingAdminStatus INTEGER
+ }
+
+ mip6BindingHomeAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6BindingHomeAddress
+ that follows.
+ "
+ ::= { mip6BindingCacheEntry 1 }
+
+ mip6BindingHomeAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The home address of the mobile node corresponding
+ to the Binding Cache entry. This field is used as
+ the key for searching the mobile node's current
+ care-of address in the Binding Cache.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6BindingHomeAddressType object.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 2 }
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 11]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingCOAType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6BindingCOA that
+ follows.
+ "
+ ::= { mip6BindingCacheEntry 3 }
+
+ mip6BindingCOA OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The care-of address of the mobile node indicated by
+ the home address field (mip6BindingHomeAddress) in
+ this Binding Cache entry.
+
+ The type of the address represented by this object
+ is specified by the corresponding mip6BindingCOAType
+ object.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 4 }
+
+ mip6BindingTimeRegistered OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp when this Binding Cache entry was
+ created.
+ "
+ ::= { mip6BindingCacheEntry 5 }
+
+ mip6BindingTimeGranted OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lifetime in seconds granted to the mobile node
+ for this registration.
+ "
+ ::= { mip6BindingCacheEntry 6 }
+
+
+
+
+Keeni, et al. Standards Track [Page 12]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingTimeRemaining OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lifetime in seconds remaining for this
+ registration.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 7 }
+
+ mip6BindingHomeRegn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates whether or not this Binding
+ Cache entry is a home registration entry (applicable
+ only on nodes that support home agent
+ functionality).
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 8 }
+
+ mip6BindingMaxSeq OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65536)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum value of the Sequence Number field
+ received in previous Binding Updates for this home
+ address (mip6BindingHomeAddress).
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1, 9.5.1"
+ ::= { mip6BindingCacheEntry 9 }
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 13]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingUsageTS OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp when this entry was last looked up.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 10 }
+
+ mip6BindingUsageCount OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this entry was looked up.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 11 }
+
+ mip6BindingAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ active (1),
+ inactive (2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This is an administrative object used to control
+ the status of a binding cache entry. By default
+ the value will be 'active'(1).
+ A value of 'inactive'(2) will indicate that the
+ validity of the entry is suspended. It does not
+ exist in the binding cache for all practical
+ purposes.
+ The state can be changed from 'active' to
+ 'inactive' by operator intervention.
+ Causing the state to change to 'inactive' results
+ in the entry being deleted from the cache.
+ Attempts to change the status from 'inactive'
+ to 'active' will be rejected.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.1"
+ ::= { mip6BindingCacheEntry 12 }
+
+
+
+
+Keeni, et al. Standards Track [Page 14]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- mip6BindingHistory
+ -- Once the lifetime expires an entry will be removed from the
+ -- Binding Cache.
+ -- For monitoring purposes it will be useful to have access to
+ -- the history of the Binding Cache. BindingHistoryTable serves
+ -- this purpose. It records the history of the Bindings.
+ -- The size of the table will be left to implementors.
+
+ mip6BindingHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6BindingHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing a record of the bindings.
+ "
+ ::= { mip6Bindings 2 }
+
+ mip6BindingHistoryEntry OBJECT-TYPE
+ SYNTAX Mip6BindingHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The record of a binding.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6BindingHstHomeAddress
+ exceeds 112, then OIDs of column
+ instances in this row will have more than 128
+ sub-identifiers and cannot be accessed using
+ SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6BindingHstHomeAddressType,
+ mip6BindingHstHomeAddress ,
+ mip6BindingHstIndex}
+ ::= { mip6BindingHistoryTable 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 15]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ Mip6BindingHistoryEntry ::=
+ SEQUENCE {
+ mip6BindingHstHomeAddressType InetAddressType,
+ mip6BindingHstHomeAddress InetAddress,
+ mip6BindingHstIndex Unsigned32,
+ mip6BindingHstCOAType InetAddressType,
+ mip6BindingHstCOA InetAddress,
+ mip6BindingHstTimeRegistered DateAndTime,
+ mip6BindingHstTimeExpired DateAndTime,
+ mip6BindingHstHomeRegn TruthValue,
+ mip6BindingHstUsageTS DateAndTime,
+ mip6BindingHstUsageCount Gauge32
+ }
+
+ mip6BindingHstHomeAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the
+ mip6BindingHstHomeAddress that follows.
+ "
+ ::= { mip6BindingHistoryEntry 1 }
+
+ mip6BindingHstHomeAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Mobile node's home address.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6BindingHstHomeAddressType object.
+ "
+ ::= { mip6BindingHistoryEntry 2 }
+
+ mip6BindingHstIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index to uniquely identify this record along
+ with the mobile node's HomeAddress type and
+ HomeAddress. It should be monotonically increasing.
+ It may wrap after reaching its max value."
+ ::= { mip6BindingHistoryEntry 3 }
+
+
+
+
+Keeni, et al. Standards Track [Page 16]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingHstCOAType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6BindingHstCOA that
+ follows.
+ "
+ ::= { mip6BindingHistoryEntry 4 }
+
+ mip6BindingHstCOA OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Mobile node's care-of address. One mobile node can
+ have multiple bindings with different
+ care-of addresses.
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6BindingHstCOAType object.
+ "
+ ::= { mip6BindingHistoryEntry 5 }
+
+ mip6BindingHstTimeRegistered OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp when this Binding Cache entry was
+ created.
+ "
+ ::= { mip6BindingHistoryEntry 6 }
+
+ mip6BindingHstTimeExpired OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp when this Binding Cache entry expired.
+ "
+ ::= { mip6BindingHistoryEntry 7 }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 17]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingHstHomeRegn OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates whether or not this Binding
+ Cache entry is a home registration entry (applicable
+ only on nodes that support home agent
+ functionality).
+ "
+ ::= { mip6BindingHistoryEntry 8 }
+
+ mip6BindingHstUsageTS OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp when this entry was last looked up.
+ "
+ ::= { mip6BindingHistoryEntry 9 }
+
+ mip6BindingHstUsageCount OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this entry was looked up.
+ "
+ ::= { mip6BindingHistoryEntry 10 }
+
+ -- mip6TrafficCounters
+
+ -- MIPv6 Traffic will be characterized by
+ -- IPv6 datagrams which satisfy at least one of the following
+ -- conditions
+ -- - the datagrams are tunneled to the mobile node by the HA
+ -- - the datagrams are reverse tunneled by the MN to the HA
+ -- - the datagrams have the Routing header type 2 set.
+ -- - the datagrams have the Home Address option set in the
+ -- Destination Option extension header
+ -- - the datagrams have the mobility header
+
+ mip6TotalTraffic OBJECT IDENTIFIER ::= { mip6Stats 1 }
+ -- REFERENCE
+ -- "RFC 3775 : Section 4.1, 6.3, 6.4"
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 18]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6InOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ received by the MIPv6 entity. This will include
+ datagrams with the Mobility Header, the Home Address
+ option in the Destination Option extension header
+ (Next Header value = 60), or the type 2 Routing
+ Header. It will also include the IPv6 datagrams that
+ are reverse tunneled to a home agent from a mobile
+ node's home address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 1 }
+
+ mip6HCInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ received by the MIPv6 entity. This will include
+ datagrams with the Mobility Header, the Home Address
+ option in the Destination Option extension header
+ (Next Header value = 60), or the type 2 Routing
+ Header. It will also include the IPv6 datagrams that
+ are reverse tunneled to a home agent from a mobile
+ node's home address.
+ This object is a 64-bit version of mip6InOctets.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 2 }
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 19]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6InPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams received by the MIPv6
+ entity. This will include datagrams with the
+ Mobility Header, the Home Address option in the
+ Destination Option extension header (Next Header
+ value = 60), or the type 2 Routing Header.
+ It will also include the IPv6 datagrams that are
+ reverse tunneled to a home agent from a mobile
+ node's home address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 3 }
+
+ mip6HCInPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams received by the MIPv6
+ entity. This will include datagrams with the
+ Mobility Header, the Home Address option in the
+ Destination Option extension header (Next Header
+ value = 60), or the type 2 Routing Header. It will
+ also include the IPv6 datagrams that are reverse
+ tunneled to a home agent from a mobile node's home
+ address.
+ This object is a 64-bit version of mip6InPkts.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 4 }
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 20]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6OutOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ sent by the MIPv6 entity. This will include
+ datagrams with the Mobility Header, the Home Address
+ option in the Destination Option extension header
+ (Next Header value = 60), or the type 2 Routing
+ Header. It will also include the IPv6 datagrams that
+ are reverse tunneled to a home agent from a mobile
+ node's home address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 5 }
+
+ mip6HCOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ sent by the MIPv6 entity. This will include
+ datagrams with the Mobility Header, the Home Address
+ option in the Destination Option extension header
+ (Next Header value = 60), or the type 2 Routing
+ Header. It will also include the IPv6 datagrams that
+ are reverse tunneled to a home agent from a mobile
+ node's home address.
+ This object is a 64-bit version of mip6OutOctets.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 6 }
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 21]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6OutPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams sent by the MIPv6
+ entity. This will include the datagrams with
+ Mobility Header, the Home Address option in the
+ Destination Option extension header (Next Header
+ value = 60), or the type 2 Routing Header. It will
+ also include the IPv6 datagrams that are reverse
+ tunneled to a home agent from a mobile node's home
+ address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 7 }
+
+ mip6HCOutPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams sent by the MIPv6
+ entity. This will include datagrams with the
+ Mobility Header, the Home Address option in the
+ Destination Option extension header (Next Header
+ value = 60), or the type 2 Routing Header. It will
+ also include the IPv6 datagrams that are reverse
+ tunneled to a home agent from a mobile node's home
+ address.
+ This object is a 64-bit version of mip6OutPkts.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6TotalTraffic 8 }
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 22]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CounterDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime on the most recent occasion
+ at which any one or more of this MIPv6 entities
+ global counters, viz., counters with OID prefix
+ 'mip6TotalTraffic' or 'mip6CnGlobalStats' or
+ 'mip6HaGlobalStats' suffered a discontinuity.
+ If no such discontinuities have occurred since the
+ last re-initialization of the local management
+ subsystem, then this object will have a zero value.
+ "
+ ::= { mip6TotalTraffic 9 }
+
+
+ -- mip6NodeTrafficCounters
+
+ mip6NodeTrafficTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6NodeTrafficEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing MIPv6 traffic counters per mobile
+ node.
+ "
+ ::= { mip6Stats 2 }
+
+ mip6NodeTrafficEntry OBJECT-TYPE
+ SYNTAX Mip6NodeTrafficEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The MIPv6 traffic statistics for a mobile node.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6BindingHomeAddress
+ exceeds 113, then OIDs of column
+ instances in this row will have more than 128
+ sub-identifiers and cannot be accessed using
+ SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6BindingHomeAddressType, mip6BindingHomeAddress }
+ ::= { mip6NodeTrafficTable 1 }
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 23]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ Mip6NodeTrafficEntry ::=
+ SEQUENCE {
+ mip6NodeInOctets Counter32,
+ mip6HCNodeInOctets Counter64,
+ mip6NodeInPkts Counter32,
+ mip6HCNodeInPkts Counter64,
+ mip6NodeOutOctets Counter32,
+ mip6HCNodeOutOctets Counter64,
+ mip6NodeOutPkts Counter32,
+ mip6HCNodeOutPkts Counter64,
+ mip6NodeCtrDiscontinuityTime TimeStamp
+ }
+
+ mip6NodeInOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ received from the mobile node by the MIPv6 entity.
+ This will include datagrams with the Mobility
+ Header or the Home Address option in the Destination
+ Option extension header (Next Header value = 60).
+ It will also include the IPv6 datagrams that are
+ reverse tunneled to a home agent from the mobile
+ node's home address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 24]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HCNodeInOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ received from the mobile node by the MIPv6 entity.
+ This will include datagrams with the Mobility
+ Header or the Home Address option in the Destination
+ Option extension header (Next Header value = 60).
+ It will also include the IPv6 datagrams that are
+ reverse tunneled to a home agent from the mobile
+ node's home address.
+ This object is a 64-bit version of mip6NodeInOctets.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 2 }
+
+ mip6NodeInPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams received from the
+ mobile node by the MIPv6 entity. This will include
+ the datagrams with the Mobility Header or
+ the Home Address option in the Destination
+ Option extension header (Next Header value = 60).
+ It will also include the IPv6 datagrams that are
+ reverse tunneled to a home agent from the mobile
+ node's home address.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 3 }
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 25]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HCNodeInPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams received from the
+ mobile node by the MIPv6 entity. This will include
+ datagrams with the Mobility Header or the Home
+ Address option in the Destination Option extension
+ header (Next Header value = 60). It will also
+ include the IPv6 datagrams that are reverse tunneled
+ to a home agent from the mobile node's home address.
+ This object is a 64-bit version of mip6NodeInPkts.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 4 }
+
+ mip6NodeOutOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ sent to the mobile node by the MIPv6 entity. This
+ will include datagrams with the Mobility Header
+ or the type 2 Routing Header. It will also include
+ the IPv6 datagrams that are tunneled by a home agent
+ to the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 5 }
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 26]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HCNodeOutOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets in the MIPv6 datagrams
+ sent to the mobile node by the MIPv6 entity. This
+ will include datagrams with the Mobility Header
+ or the type 2 Routing Header. It will also include
+ the IPv6 datagrams that are tunneled by a home agent
+ to the mobile node.
+ This object is a 64-bit version of mip6NodeOutOctets.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 6 }
+
+ mip6NodeOutPkts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams sent to the mobile
+ node by the MIPv6 entity. This will include
+ datagrams with the Mobility Header or the type 2
+ Routing Header. It will also include the IPv6
+ datagrams that are tunneled by a home agent to the
+ mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 7 }
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 27]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HCNodeOutPkts OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of MIPv6 datagrams sent to the mobile
+ node by the MIPv6 entity. This will include
+ datagrams with the Mobility Header or the type 2
+ Routing Header. It will also include the IPv6
+ datagrams that are tunneled by a home agent to the
+ mobile node.
+ This object is a 64-bit version of mip6NodeOutOctets.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6NodeCtrDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1, 6.3, 6.4, 10.4.5"
+ ::= { mip6NodeTrafficEntry 8 }
+
+ mip6NodeCtrDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime on the most recent occasion
+ at which any one or more of the counters in this row
+ suffered a discontinuity. The relevant counters are
+ the specific instances of any Counter32 or Counter64
+ objects in this row.
+ If no such discontinuities have occurred since the
+ last re-initialization of the local management
+ subsystem, then this object contains a zero value.
+ "
+ ::= { mip6NodeTrafficEntry 9 }
+
+ -- mip6MnSystem Group
+
+ mip6MnHomeAddressTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6MnHomeAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing registration status for all the
+ home addresses pertaining to the mobile node.
+ "
+ ::= { mip6MnSystem 1 }
+
+
+
+Keeni, et al. Standards Track [Page 28]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnHomeAddressEntry OBJECT-TYPE
+ SYNTAX Mip6MnHomeAddressEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The registration status for a home address.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6MnHomeAddress
+ exceeds 113, then OIDs of column instances in
+ this row will have more than 128 sub-identifiers and
+ cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6MnHomeAddressType, mip6MnHomeAddress }
+ ::= { mip6MnHomeAddressTable 1 }
+
+ Mip6MnHomeAddressEntry ::=
+ SEQUENCE {
+ mip6MnHomeAddressType InetAddressType,
+ mip6MnHomeAddress InetAddress,
+ mip6MnHomeAddressState INTEGER
+ }
+
+ mip6MnHomeAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6MnHomeAddress that
+ follows.
+ "
+ ::= { mip6MnHomeAddressEntry 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 29]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnHomeAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A unicast routable address assigned to the mobile
+ node. This is used as the 'permanent address' of the
+ mobile node in the sense that it remains unchanged
+ regardless of the mobile node's current point of
+ attachment. If mobile node doesn't have a home
+ address assigned yet, then this object will take the
+ default 'unspecified' value ::0.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6MnHomeAddressType object.
+ "
+ REFERENCE
+ "RFC 3775 : Section 3.2"
+ ::= { mip6MnHomeAddressEntry 2 }
+
+ mip6MnHomeAddressState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ home(2),
+ registered(3),
+ pending(4),
+ isolated(5)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the state of the mobile node:
+ unknown -- The state of the mobile node
+ cannot be determined.
+ home -- mobile node is on the home network.
+ registered -- mobile node is on a foreign network
+ and is registered with the home
+ agent.
+ pending -- mobile node has sent registration
+ request to the home agent and is
+ waiting for the reply.
+ isolated -- mobile node is isolated from network,
+ i.e., it is not in its home network,
+ it is not registered, and no
+ registration ack is pending.
+ "
+ ::= { mip6MnHomeAddressEntry 3 }
+
+
+
+Keeni, et al. Standards Track [Page 30]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- Mobile Node Discovery and Advertisement Group Counters
+
+ mip6MnDiscoveryRequests OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Dynamic Home Agent Address
+ Discovery Requests sent by the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.5, 11.4.1"
+ ::= { mip6MnConf 1 }
+
+ mip6MnDiscoveryReplies OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Dynamic Home Agent Address
+ Discovery Replies received by the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.5, 11.4.1"
+ ::= { mip6MnConf 2 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 31]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnDiscoveryTimeouts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Dynamic Home Agent Address
+ Discovery Requests that timed out.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.5, 11.4.1, 12"
+ ::= { mip6MnConf 3 }
+
+ mip6MnPrefixSolicitationsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Mobile Prefix Solicitations
+ sent by the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.5, 11.4.2"
+ ::= { mip6MnConf 4 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 32]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnPrefixAdvsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Mobile Prefix Advertisements
+ received by the mobile node. This will include the
+ ICMP Mobile Prefix Advertisements that failed the
+ validity checks.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.6, 11.4.3"
+ ::= { mip6MnConf 5 }
+
+ mip6MnPrefixAdvsIgnored OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Mobile Prefix Advertisements
+ discarded by the validity check.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.6, 11.4.3"
+ ::= { mip6MnConf 6 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 33]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnMovedToFN OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the mobile node has detected
+ movement to a foreign network from another
+ foreign network or from the home network, has
+ reconstructed its care-of address and has initiated
+ the care-of address registration process.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.5.1"
+ ::= { mip6MnConf 7 }
+
+ mip6MnMovedToHN OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of times the mobile node has detected
+ movement from a foreign network to its home
+ network.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.5.4"
+ ::= { mip6MnConf 8 }
+
+ -- Mobile Node Registration Group
+
+ -- Registration table of mobile node
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 34]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBLTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6MnBLEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table corresponds to the Binding Update List
+ (BL) that is maintained by the mobile node. The list
+ holds an item for every binding that the mobile node
+ has established or is trying to establish. Both
+ correspondent and home registrations are included in
+ this table. Entries from the table are deleted as
+ the lifetime of the binding expires.
+ "
+ REFERENCE
+ "RFC 3775 : Section 4.5, 11.1"
+ ::= { mip6MnRegistration 1 }
+
+ mip6MnBLEntry OBJECT-TYPE
+ SYNTAX Mip6MnBLEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a Binding Update sent by the
+ mobile node either to its home agent or to one of
+ its correspondent nodes.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6MnHomeAddress and
+ mip6MnBLNodeAddress exceeds 111, then OIDs of column
+ instances in this row will have more than 128
+ sub-identifiers and cannot be accessed using
+ SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6MnHomeAddressType,
+ mip6MnHomeAddress,
+ mip6MnBLNodeAddressType,
+ mip6MnBLNodeAddress
+ }
+ ::= { mip6MnBLTable 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 35]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ Mip6MnBLEntry ::= SEQUENCE {
+ mip6MnBLNodeAddressType InetAddressType,
+ mip6MnBLNodeAddress InetAddress,
+ mip6MnBLCOAType InetAddressType,
+ mip6MnBLCOA InetAddress,
+ mip6MnBLLifeTimeRequested Unsigned32,
+ mip6MnBLLifeTimeGranted Unsigned32,
+ mip6MnBLMaxSeq Unsigned32,
+ mip6MnBLTimeSent DateAndTime,
+ mip6MnBLAccepted TruthValue,
+ mip6MnBLAcceptedTime DateAndTime,
+ mip6MnBLRetransmissions Gauge32,
+ mip6MnBLDontSendBUFlag TruthValue
+ }
+
+ mip6MnBLNodeAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6MnBLNodeAddress
+ that follows.
+ "
+ ::= { mip6MnBLEntry 1 }
+
+ mip6MnBLNodeAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The address of the agent as used in the destination
+ address of the Binding Update. The agent
+ may be a home agent or a correspondent node.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6MnBLNodeAddressType object.
+
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 2 }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 36]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBLCOAType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The InetAddressType of the mip6MnBLCOA that follows.
+ "
+ ::= { mip6MnBLEntry 3 }
+
+ mip6MnBLCOA OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Care-of address that the mobile node intends to
+ register in the Binding Update request.
+
+ The type of the address represented by this object
+ is specified by the corresponding mip6MnBLCOAType
+ object.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 4 }
+
+ mip6MnBLLifeTimeRequested OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lifetime requested by the mobile node (in
+ seconds) in the Binding Update.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 5 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 37]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBLLifeTimeGranted OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lifetime granted to the mobile node for this
+ binding. This field will be inaccessible if the
+ Binding Update request has not been accepted.
+ The lifetime remaining (lR) can be calculated using
+ the current time (cT), mip6MnBLAcceptedTime (aT) and
+ mip6MnBLLifeTimeGranted (lG) as follows:
+ lR = lG - (cT - aT).
+ When lR is zero, this entry will be deleted from the
+ Binding Update List and consequently from this
+ table.
+ "
+ ::= { mip6MnBLEntry 6 }
+
+ mip6MnBLMaxSeq OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65536)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum value of the Sequence Number field sent
+ in previous Binding Updates to this destination.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 7 }
+
+ mip6MnBLTimeSent OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time when the last (re-)transmission occurred."
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 8 }
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 38]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBLAccepted OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "true(1) if the mobile node has received a
+ binding acknowledgment indicating that service has
+ been accepted (status code 0 or 1); false(2)
+ otherwise. false(2) implies that the registration
+ is still pending.
+ "
+ ::= { mip6MnBLEntry 9 }
+
+ mip6MnBLAcceptedTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which the mobile node receives a binding
+ acknowledgment indicating that Binding Update has
+ been accepted (status code 0 or 1);
+ This object will be inaccessible if the Binding
+ Update request is still pending.
+ "
+ ::= { mip6MnBLEntry 10 }
+
+
+ mip6MnBLRetransmissions OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Binding Update retransmissions.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 11 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 39]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBLDontSendBUFlag OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "true(1) indicates that future binding updates
+ will not be sent to mip6MnBLNodeAddress.
+ false(2) implies that binding updates will be
+ sent to mip6MnBLNodeAddress.
+ The mobile node sets this flag in the when it
+ receives an ICMP Parameter Problem, Code 1,
+ error message in response to a return
+ routability message or Binding Update sent to
+ mip6MnBLNodeAddress.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.1"
+ ::= { mip6MnBLEntry 12 }
+
+
+ -- Mobile Node Registration Group Counters
+
+ mip6MnRegnCounters OBJECT IDENTIFIER ::= { mip6MnRegistration 2 }
+
+ mip6MnMobilityMessagesSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of mobility messages, i.e., IPv6
+ datagrams with Mobility Header, sent by the mobile
+ node. There are 3 types of mobility messages, viz.,
+ Home Test Init, Care-of Test Init, and Binding
+ Updates, that are sent by mobile nodes.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 4.2, 6.1"
+ ::= { mip6MnRegnCounters 1 }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 40]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnMobilityMessagesRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of mobility messages, i.e., IPv6
+ datagrams with Mobility Header, received by the
+ mobile node. There are 5 types of mobility
+ messages, viz., Home Test, Care-of Test, Binding
+ Acknowledgment, Binding Refresh Request, and Binding
+ Error, that are sent to mobile nodes.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 4.2, 6.1"
+ ::= { mip6MnRegnCounters 2 }
+
+ mip6MnBUsToHA OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates sent to the mobile
+ node's home agent(s).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.7.1"
+ ::= { mip6MnRegnCounters 3 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 41]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBUAcksFromHA OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of valid binding acknowledgments
+ received from the mobile node's home agent(s).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.7.3"
+ ::= { mip6MnRegnCounters 4 }
+
+ mip6MnBUsToCN OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates sent to
+ correspondent nodes by the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.7.2"
+ ::= { mip6MnRegnCounters 5 }
+
+ mip6MnBUAcksFromCN OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of valid Binding Update acks
+ received from all the correspondent nodes.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.7.3"
+ ::= { mip6MnRegnCounters 6 }
+
+
+
+
+Keeni, et al. Standards Track [Page 42]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBindingErrorsFromCN OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Error messages received
+ by mobile node from CN.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ ::= { mip6MnRegnCounters 7 }
+
+ mip6MnICMPErrorsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of ICMP Error messages of type ICMP
+ Parameter Problem, Code 1 or Code 2, received by
+ the mobile node from a correspondent node in
+ response to a return routability procedure, a
+ Binding Update, or a packet with the Home Address
+ option.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.3.5"
+ ::= { mip6MnRegnCounters 8 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 43]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBRRequestsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Refresh requests
+ received by the mobile node from correspondent
+ nodes.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.7.4"
+ ::= { mip6MnRegnCounters 9 }
+
+ -- Registration Group counters used for Correspondent Node
+ mip6CnGlobalStats OBJECT IDENTIFIER ::= { mip6CnStats 1 }
+
+
+ mip6CnHomeTestInitsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Home Test Init messages received.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.4.1"
+ ::= { mip6CnGlobalStats 1 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 44]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnHomeTestsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Home Test messages sent. If a Home
+ Test Init message is found to be valid, a Home Test
+ message will be generated and sent. Otherwise the
+ Home Test message is silently discarded.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.4.3"
+ ::= { mip6CnGlobalStats 2 }
+
+ mip6CnCareOfTestInitsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Care-of Test Init messages received.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.4.2"
+ ::= { mip6CnGlobalStats 3 }
+
+ mip6CnCareOfTestsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Care-of Test messages sent. If a
+ Care-of Test Init message is found to be valid, a
+ Care-of Test message will be generated and sent.
+ Otherwise the Care-of Test message is silently
+ discarded.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.4.4"
+ ::= { mip6CnGlobalStats 4 }
+
+
+
+
+Keeni, et al. Standards Track [Page 45]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnBUsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates received by the
+ correspondent node from mobile nodes.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1"
+ ::= { mip6CnGlobalStats 5 }
+
+ mip6CnBUAcksSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of acknowledgments sent by the
+ correspondent node for the Binding Updates received.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.4"
+ ::= { mip6CnGlobalStats 6 }
+
+
+ mip6CnBRsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Refresh Request messages
+ sent by the correspondent node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.5"
+ ::= { mip6CnGlobalStats 7 }
+
+
+
+Keeni, et al. Standards Track [Page 46]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnBindingErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Error messages sent by the
+ correspondent node to the mobile node.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.3.3"
+ ::= { mip6CnGlobalStats 8 }
+
+ mip6CnBUsAccepted OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates accepted by the
+ correspondent node. If a Binding Acknowledgment
+ message is sent for the Binding Update request,
+ the Status code field in the message will have
+ a value less than 128.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1, 9.5.4"
+ ::= { mip6CnGlobalStats 9 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 47]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnBUsRejected OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected
+ by the correspondent node. If a Binding
+ Acknowledgment message has been sent for the Binding
+ Update request, the Status code field in the
+ message will have a value greater than or equal to
+ 128. Otherwise the Binding Update request will be
+ silently discarded.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1, 9.5.4"
+ ::= { mip6CnGlobalStats 10 }
+
+ mip6CnReasonUnspecified OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the correspondent node with status code in the
+ Binding Acknowledgment message indicating 'reason
+ unspecified' (Code 128).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8"
+ ::= { mip6CnGlobalStats 11 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 48]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnInsufficientResource OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the correspondent node with status code in the
+ Binding Acknowledgment message indicating
+ 'insufficient resources' (Code 130).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8"
+ ::= { mip6CnGlobalStats 12 }
+
+ mip6CnHomeRegnNotSupported OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'home registration
+ not supported' (Code 131).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6CnGlobalStats 13 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 49]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnSeqNumberOutOfWindow OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'sequence number
+ out of window' (Code 135).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8, 9.5.1"
+ ::= { mip6CnGlobalStats 14 }
+
+ mip6CnExpiredHomeNonceIndex OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Updates rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'expired home
+ nonce index' (Code 136).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8, 9.5.1"
+ ::= { mip6CnGlobalStats 15 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 50]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnExpiredCareOfNonceIndex OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Updates rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'expired
+ care-of nonce index' (Code 137).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8, 9.5.1"
+ ::= { mip6CnGlobalStats 16 }
+
+ mip6CnExpiredNonce OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Updates rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'expired nonces'
+ (Code 138), i.e., the correspondent node no longer
+ recognizes the Home Nonce Index value and the
+ Care-of Nonce Index value.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8, 9.5.1"
+ ::= { mip6CnGlobalStats 17 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 51]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnRegTypeChangeDisallowed OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Updates rejected by
+ correspondent node with status code in the Binding
+ Acknowledgment message indicating 'registration
+ type change disallowed' (Code 139), i.e., a binding
+ already exists for the given home address and the
+ home registration flag has a different value than
+ the Home Registration (H) bit in the Binding Update.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8, 9.5.1"
+ ::= { mip6CnGlobalStats 18 }
+
+
+
+ -- The Correspondent Node statistics by mobile node
+
+ mip6CnCounterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6CnCounterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing each mobile ."
+ ::= { mip6CnStats 2 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 52]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnCounterEntry OBJECT-TYPE
+ SYNTAX Mip6CnCounterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The set of correspondent node counters for a mobile
+ node.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6BindingHomeAddress
+ exceeds 113, then OIDs of column instances in
+ this row will have more than 128 sub-identifiers and
+ cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6BindingHomeAddressType,
+ mip6BindingHomeAddress
+ }
+ ::= { mip6CnCounterTable 1 }
+
+ Mip6CnCounterEntry ::=
+ SEQUENCE {
+ mip6CnBURequestsAccepted Counter32,
+ mip6CnBURequestsRejected Counter32,
+ mip6CnBCEntryCreationTime DateAndTime,
+ mip6CnBUAcceptedTime DateAndTime,
+ mip6CnBURejectionTime DateAndTime,
+ mip6CnBURejectionCode Mip6BURequestRejectionCode,
+ mip6CnCtrDiscontinuityTime TimeStamp
+ }
+
+ mip6CnBURequestsAccepted OBJECT-TYPE --(Code 0,1)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests from the
+ mobile node accepted by the correspondent node.
+ If Binding Acknowledgment messages are sent, then
+ the status code in the message will have a value
+ less than 128.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CnCtrDiscontinuityTime.
+ "
+ ::= { mip6CnCounterEntry 1 }
+
+
+
+
+
+Keeni, et al. Standards Track [Page 53]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnBURequestsRejected OBJECT-TYPE
+ -- (Code 128 through Code 159)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests from the
+ mobile node that have been rejected by the
+ correspondent node. This includes the Binding Update
+ requests for which a Binding Acknowledgment message
+ has been sent with status code value greater than or
+ equal to 128 and the Binding Acknowledgment requests
+ that have been silently discarded.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CnCtrDiscontinuityTime.
+ "
+ ::= { mip6CnCounterEntry 2 }
+
+ mip6CnBCEntryCreationTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time when the current Binding Cache entry was
+ created for the mobile node.
+ "
+ ::= { mip6CnCounterEntry 3 }
+
+ mip6CnBUAcceptedTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which the last Binding Update was
+ accepted by the correspondent node and the
+ corresponding Binding Cache entry was updated.
+ "
+ ::= { mip6CnCounterEntry 4 }
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 54]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnBURejectionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which the last Binding Update message
+ was rejected by the correspondent node.
+ If there have been no rejections, then this object
+ will be inaccessible.
+ "
+ ::= { mip6CnCounterEntry 5 }
+
+ mip6CnBURejectionCode OBJECT-TYPE
+ SYNTAX Mip6BURequestRejectionCode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If a Binding Acknowledgment is sent to the mobile
+ node, this is the status code (> 128) that is
+ returned in the Binding Acknowledgment.
+ In case a Binding Acknowledgment is not sent to
+ the mobile node, then this will be the value
+ of the Status code that corresponds to the reason
+ of the rejection. If there have been no
+ rejections, then this object will be inaccessible.
+ "
+ REFERENCE
+ "RFC 3775 : Section 6.1.8"
+
+ ::= { mip6CnCounterEntry 6 }
+
+ mip6CnCtrDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime on the most recent occasion
+ at which any one or more of counters in this row,
+ viz., instances of 'mip6CnBURequestsAccepted' and
+ 'mip6CnBURequestsRejected', suffered a discontinuity.
+ If no such discontinuities have occurred since the
+ last re-initialization of the local management
+ subsystem, then this object will have a zero value.
+ "
+ ::= { mip6CnCounterEntry 7 }
+
+ -- Home agent group
+
+
+
+
+Keeni, et al. Standards Track [Page 55]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaAdvsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of valid Router Advertisements
+ received with the Home Agent (H) bit set, on
+ all the links on which it is serving as a Home
+ Agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 7"
+ ::= { mip6HaAdvertisement 1 }
+
+
+ mip6HaAdvsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of unsolicited multicast Router
+ Advertisements sent with the Home Agent (H) bit set,
+ on all the links on which the router is serving as
+ a Home Agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 7"
+ ::= { mip6HaAdvertisement 2 }
+
+
+ mip6HaConfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6HaConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing configurable advertisement
+ parameters for all interfaces on which the
+ home agent service is advertised.
+ It is RECOMMENDED that the last written values
+ of the objects in the conceptual rows of this
+
+
+
+Keeni, et al. Standards Track [Page 56]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ table will remain unchanged across reboots of
+ the managed entity provided that the interfaces
+ have not been renumbered after the reboot.
+ "
+ ::= { mip6HaAdvertisement 3 }
+
+ mip6HaConfEntry OBJECT-TYPE
+ SYNTAX Mip6HaConfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Advertisement parameters for an interface.
+ The instances of the columnar objects in this entry
+ pertain to the interface that is uniquely identified
+ by the ipv6InterfaceIfIndex of the interface. The
+ same ipv6InterfaceIfIndex object is used to uniquely
+ identify instances of the columnar objects of this
+ conceptual row.
+ "
+ INDEX { ipv6InterfaceIfIndex }
+ ::= { mip6HaConfTable 1 }
+
+ Mip6HaConfEntry ::= SEQUENCE {
+ mip6HaAdvPreference Integer32,
+ mip6HaAdvLifetime Integer32,
+ mip6HaPrefixAdv INTEGER,
+ mip6HaPrefixSolicitation INTEGER,
+ mip6HaMCastCtlMsgSupport INTEGER
+ }
+
+ mip6HaAdvPreference OBJECT-TYPE
+ SYNTAX Integer32 (0..65536)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The preference value for the home agent to
+ be used in the Router Advertisements. Higher
+ value denotes greater preference.
+ "
+ REFERENCE
+ "RFC 3775 : Section 7.4, 8.4"
+ ::= { mip6HaConfEntry 1 }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 57]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaAdvLifetime OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ UNITS "seconds"
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The lifetime value for the home agent to be
+ used in the Router Advertisements.
+ "
+ REFERENCE
+ "RFC 3775 : Section 7.4"
+ ::= { mip6HaConfEntry 2 }
+
+ mip6HaPrefixAdv OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the home agent should support
+ sending of the ICMP Mobile Prefix Advertisements.
+ If it is disabled(2), the home agent will not
+ send ICMP Mobile Prefix Advertisements to the
+ mobile nodes.
+ The state can be changed from enabled(1) to
+ disabled(2) and vice versa by operator
+ intervention.
+ Causing the state to change from enabled(1) to
+ disabled(2) will result in the home agent
+ disabling the Prefix advertisement function.
+ On the other hand, changing the status from
+ disabled(2) to enabled(1) will start the prefix
+ advertisement function.
+ "
+ REFERENCE
+ "RFC 3775 : Section 8.4"
+ ::= { mip6HaConfEntry 3}
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 58]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaPrefixSolicitation OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the home agent should respond
+ to ICMP Mobile Prefix Solicitation messages it
+ receives from the mobile nodes. By default, the
+ value will be set to enabled(1). If it is
+ disabled(2), the home agent will not respond to
+ any ICMP Mobile Prefix Solicitation messages.
+ The state can be changed from enabled(1) to
+ disabled(2), by operator intervention. Causing
+ the state to change from enabled(1) to
+ disabled(2) will result in the home agent not
+ responding to any ICMP Mobile Prefix
+ Solicitation messages it receives from the
+ mobile nodes.
+ "
+ REFERENCE
+ "RFC 3775 : Section 8.4"
+ ::= { mip6HaConfEntry 4}
+
+
+ mip6HaMCastCtlMsgSupport OBJECT-TYPE
+ SYNTAX INTEGER { enabled(1), disabled(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Indicates whether the home agent should enable
+ support for the processing of the multicast
+ group membership control messages it receives
+ from the mobile nodes. By default, the value
+ will be set to enabled(1). If it is
+ disabled(2), the home agent will not process
+ any multicast group control messages it receives
+ from the mobile nodes.
+ The state can be changed from enabled(1) to
+ disabled(2), by operator intervention. Causing
+ the state to change from enabled(1) to
+ disabled(2) will result in the home agent
+ disabling the processing of the multicast group
+ control messages it received from the mobile
+ nodes.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.4.3"
+ ::= { mip6HaConfEntry 5}
+
+
+
+Keeni, et al. Standards Track [Page 59]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+
+ -- Registration Group counters HA
+
+ mip6HaGlobalStats OBJECT IDENTIFIER ::= { mip6HaStats 1 }
+
+ mip6HaHomeTestInitsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Home Test Init messages received by
+ the home agent. This will include Home Test Init
+ messages that failed the validity checks.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 5.2.5"
+ ::= { mip6HaGlobalStats 1 }
+
+ mip6HaHomeTestsSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Home Test messages sent by the
+ home agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 5.2.5"
+ ::= { mip6HaGlobalStats 2 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 60]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaBUsRecd OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates received by the
+ home agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 3 }
+
+ mip6HaBUAcksSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Acknowledgments sent
+ by the home agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 4 }
+
+ mip6HaBRAdviceSent OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Acknowledgments sent
+ by the home agent with Binding Refresh Advice
+ mobility option included.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 5 }
+
+
+
+Keeni, et al. Standards Track [Page 61]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaBUsAccepted OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Updates accepted by this HA.
+ Binding Acknowledgment with status code of 0 or 1.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 6 }
+
+ mip6HaPrefDiscoverReqd OBJECT-TYPE -- (Code 1)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of Binding Acknowledgments sent by
+ the home agent with status code indicating 'accepted
+ but prefix discovery necessary' (Code 1).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 7 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 62]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaReasonUnspecified OBJECT-TYPE -- (Code 128)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'reason
+ unspecified' (Code 128).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 8 }
+
+ mip6HaAdmProhibited OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'administratively
+ prohibited' (Code 129).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 9 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 63]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaInsufficientResource OBJECT-TYPE -- (Code 130)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'insufficient
+ resources' (Code 130).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.2"
+ ::= { mip6HaGlobalStats 10 }
+
+ mip6HaHomeRegnNotSupported OBJECT-TYPE -- (Code 131)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'home
+ registration not supported' (Code 131).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 11 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 64]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaNotHomeSubnet OBJECT-TYPE -- (Code 132)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'not home subnet'
+ (Code 132).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 12 }
+
+ mip6HaNotHomeAgentForThisMN OBJECT-TYPE -- (Code 133)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'not home agent
+ for this mobile node' (Code 133).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.2"
+ ::= { mip6HaGlobalStats 13 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 65]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaDupAddrDetectionFailed OBJECT-TYPE -- (Code 134)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'Duplicate
+ Address Detection failed' (Code 134).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6HaGlobalStats 14 }
+
+ mip6HaSeqNumberOutOfWindow OBJECT-TYPE -- (Code 135)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'sequence number
+ out of window' (Code 135).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1"
+ ::= { mip6HaGlobalStats 15 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 66]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaExpiredHomeNonceIndex OBJECT-TYPE -- (Code 136)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'expired home
+ nonce index' (Code 136).
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1"
+ ::= { mip6HaGlobalStats 16 }
+
+ mip6HaRegTypeChangeDisallowed OBJECT-TYPE -- (Code 139)
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of Binding Update requests rejected by
+ the home agent with status code in the Binding
+ Acknowledgment message indicating 'registration
+ type change disallowed' (Code 139), i.e., a binding
+ already exists for the given home address and the
+ home registration flag has a different value than
+ the Home Registration (H) bit in the Binding Update.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6CounterDiscontinuityTime.
+ "
+ REFERENCE
+ "RFC 3775 : Section 9.5.1"
+ ::= { mip6HaGlobalStats 17 }
+
+ -- Home agent registration Counters per node
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 67]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaCounterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6HaCounterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table containing registration statistics for all
+ mobile nodes registered with the home agent.
+ "
+ ::= { mip6HaStats 2 }
+
+ mip6HaCounterEntry OBJECT-TYPE
+ SYNTAX Mip6HaCounterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Home agent registration statistics for a mobile
+ node.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6BindingHomeAddress
+ exceeds 113, then OIDs of column instances in
+ this row will have more than 128 sub-identifiers and
+ cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { mip6BindingHomeAddressType,
+ mip6BindingHomeAddress
+ }
+ ::= { mip6HaCounterTable 1 }
+
+ Mip6HaCounterEntry ::= SEQUENCE {
+ mip6HaBURequestsAccepted Counter32,
+ mip6HaBURequestsDenied Counter32,
+ mip6HaBCEntryCreationTime DateAndTime,
+ mip6HaBUAcceptedTime DateAndTime,
+ mip6HaBURejectionTime DateAndTime,
+ mip6HaRecentBURejectionCode Mip6BURequestRejectionCode,
+ mip6HaCtrDiscontinuityTime TimeStamp
+ }
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 68]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaBURequestsAccepted OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of service requests for the mobile node
+ accepted by the home agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6HaCtrDiscontinuityTime.
+ "
+ ::= { mip6HaCounterEntry 1 }
+
+ mip6HaBURequestsDenied OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Total number of service requests for the mobile node
+ rejected by the home agent.
+ Discontinuities in the value of this counter can
+ occur at re-initialization of the management system,
+ and at other times as indicated by the value of
+ mip6HaCtrDiscontinuityTime.
+ "
+ ::= { mip6HaCounterEntry 2 }
+
+ mip6HaBCEntryCreationTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time when the current Binding Cache entry was
+ created for the mobile node.
+ "
+ ::= { mip6HaCounterEntry 3 }
+
+ mip6HaBUAcceptedTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which the last Binding Update was
+ accepted by the home agent for this mobile node.
+ "
+ ::= { mip6HaCounterEntry 4 }
+
+
+
+Keeni, et al. Standards Track [Page 69]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaBURejectionTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time at which the last Binding Update was
+ rejected by the home agent for this mobile node.
+ If there have been no rejections, then this object
+ will be inaccessible.
+ "
+ ::= { mip6HaCounterEntry 5 }
+
+ mip6HaRecentBURejectionCode OBJECT-TYPE
+ SYNTAX Mip6BURequestRejectionCode
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If a Binding Acknowledgment is sent to the mobile
+ node, this is the status code (> 128) that is
+ returned in the Binding Acknowledgment.
+ In case a Binding Acknowledgment is not sent to the
+ mobile node, then this will be the value of the
+ status code that corresponds to the reason of the
+ rejection.
+ If there have been no rejections, then this object
+ will be inaccessible.
+ "
+ ::= { mip6HaCounterEntry 6 }
+
+ mip6HaCtrDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime on the most recent occasion
+ at which any one or more of counters in this row,
+ viz., instances of 'mip6HaBURequestsAccepted' and
+ 'mip6HaBURequestsRejected', suffered a discontinuity.
+ If no such discontinuities have occurred since the
+ last re-initialization of the local management
+ subsystem, then this object will have a zero value.
+ "
+ ::= { mip6HaCounterEntry 7 }
+
+ -- Home Agent List Table
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 70]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaListTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6HaListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table models the Home Agents List that contains
+ the list of all routers that are acting as home
+ agents on each of the interfaces on which the home
+ agent service is offered by this router.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaAdvertisement 4 }
+
+ mip6HaListEntry OBJECT-TYPE
+ SYNTAX Mip6HaListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a router that is offering home
+ agent service.
+ The instances of the columnar objects in this entry
+ pertain to an interface for a particular value of
+ mip6HaLinkLocalAddressType and
+ mip6HaLinkLocalAddress. The interface is uniquely
+ identified by its ipv6InterfaceIfIndex. The same
+ ipv6InterfaceIfIndex object is used in conjunction
+ with the mip6HaLinkLocalAddressType and
+ mip6HaLinkLocalAddress to uniquely identify
+ instances of the columnar objects of this row.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6HaLinkLocalAddress
+ exceeds 112, then OIDs of column instances in
+ this row will have more than 128 sub-identifiers and
+ cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { ipv6InterfaceIfIndex, mip6HaLinkLocalAddressType,
+ mip6HaLinkLocalAddress }
+ ::= { mip6HaListTable 1 }
+
+ Mip6HaListEntry ::= SEQUENCE {
+ mip6HaLinkLocalAddressType InetAddressType,
+ mip6HaLinkLocalAddress InetAddress,
+ mip6HaPreference Integer32,
+ mip6HaRecvLifeTime Gauge32,
+ mip6HaRecvTimeStamp DateAndTime
+ }
+
+
+
+Keeni, et al. Standards Track [Page 71]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaLinkLocalAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The address type for the link-local address
+ of the home agent that follows.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaListEntry 1 }
+
+ mip6HaLinkLocalAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The link local address of the home agent.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6HaLinkLocalAddressType object.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaListEntry 2 }
+
+ mip6HaPreference OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The preference value of this home agent.
+ Higher values indicate a more preferable home
+ agent. The preference value is obtained from
+ the preference field of the received Router
+ Advertisement.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaListEntry 3 }
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 72]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaRecvLifeTime OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The lifetime for this home agent.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaListEntry 4 }
+
+ mip6HaRecvTimeStamp OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time when the home agent advertisement was
+ received.
+ "
+ ::= { mip6HaListEntry 5 }
+
+ --
+ -- The list of global addresses of a home agent in the
+ -- home agent list
+ --
+
+ mip6HaGlAddrTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF Mip6HaGlAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains the global addresses of the home
+ agents in the Home Agents List.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaAdvertisement 5 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 73]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaGlAddrEntry OBJECT-TYPE
+ SYNTAX Mip6HaGlAddrEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A global address for a home agent in the Home Agents
+ List.
+ The instances of the columnar objects in this entry
+ pertain to an interface for a particular value of
+ mip6HaLinkLocalAddressType, mip6HaLinkLocalAddress
+ and mip6HaGaAddrSeqNo.
+ The mip6HaGaAddrSeqNo object is used to distinguish
+ between multiple instances of the home agent global
+ addresses on the same interface for the same set of
+ mip6HaLinkLocalAddressType, mip6HaLinkLocalAddress,
+ values.
+ There is no upper-bound on the maximum number of
+ global addresses on an interface but, for practical
+ purposes, the upper-bound of the value
+ mip6HaGaAddrSeqNo is set to 1024.
+ The interface is uniquely identified by its
+ ipv6InterfaceIfIndex. The same ipv6InterfaceIfIndex
+ object is used in conjunction with the
+ mip6HaLinkLocalAddressType, mip6HaLinkLocalAddress,
+ and mip6HaGaAddrSeqNo to uniquely identify instances
+ of the columnar objects of this row.
+
+ Implementors need to be aware that if the total
+ number of octets in mip6HaLinkLocalAddress
+ exceeds 111, then OIDs of column instances in
+ this row will have more than 128 sub-identifiers and
+ cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3.
+ "
+ INDEX { ipv6InterfaceIfIndex, mip6HaLinkLocalAddressType,
+ mip6HaLinkLocalAddress, mip6HaGaAddrSeqNo }
+ ::= { mip6HaGlAddrTable 1 }
+
+ Mip6HaGlAddrEntry ::= SEQUENCE {
+ mip6HaGaAddrSeqNo Integer32,
+ mip6HaGaGlobalAddressType InetAddressType,
+ mip6HaGaGlobalAddress InetAddress
+ }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 74]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaGaAddrSeqNo OBJECT-TYPE
+ SYNTAX Integer32 (1..1024)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The index that along with ipv6InterfaceIfIndex,
+ mip6HaLinkLocalAddressType, and
+ mip6HaLinkLocalAddress uniquely identifies this row.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.1"
+ ::= { mip6HaGlAddrEntry 1 }
+
+ mip6HaGaGlobalAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The address type for the global address of the
+ home agent that follows.
+ "
+ ::= { mip6HaGlAddrEntry 2 }
+
+ mip6HaGaGlobalAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A global address of the home agent.
+
+ The type of the address represented by this object
+ is specified by the corresponding
+ mip6HaGaGlobalAddressType object.
+ "
+ ::= { mip6HaGlAddrEntry 3 }
+
+ --
+ -- Notifications
+ --
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 75]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnRegistered NOTIFICATION-TYPE
+ OBJECTS {
+ mip6BindingTimeRegistered,
+ mip6BindingCOAType,
+ mip6BindingCOA
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent by a home agent when
+ a mobile node registers with the home agent
+ for the first time.
+ Notifications will not be sent for subsequent
+ updates and/or refreshes.
+ The MO instances in the notifications will be
+ identified by the mip6BindingHomeAddressType
+ and mip6BindingHomeAddress for the mobile node
+ in the mip6BindingCacheTable.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.1"
+ ::= { mip6Notifications 1 }
+
+ mip6MnDeRegistered NOTIFICATION-TYPE
+ OBJECTS {
+ mip6BindingTimeRegistered,
+ mip6BindingCOAType,
+ mip6BindingCOA
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent by a home agent every
+ time a mobile node de-registers with the home
+ agent by sending a Binding Update that requests
+ the home agent to delete a binding.
+ The MO instances in the notifications will be
+ identified by the mip6BindingHomeAddressType
+ and mip6BindingHomeAddress for the mobile node
+ in the mip6BindingCacheTable.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.2"
+ ::= { mip6Notifications 2 }
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 76]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnCOAChanged NOTIFICATION-TYPE
+ OBJECTS {
+ mip6BindingTimeRegistered,
+ mip6BindingCOAType,
+ mip6BindingCOA
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent by a home agent every
+ time a mobile node sends a Binding Update with
+ a new care-of address (for an existing Binding
+ Cache entry).
+ Notifications will not be sent for subsequent
+ updates and/or refreshes for the same Care-of
+ address.
+ The registration of a new care-of address may
+ indicate that the mobile node has moved or that
+ the primary care-of address of the mobile node
+ has become deprecated.
+ The MO instances in the notifications will be
+ identified by the mip6BindingHomeAddressType
+ and mip6BindingHomeAddress for the mobile node
+ in the mip6BindingCacheTable.
+ "
+ REFERENCE
+ "RFC 3775 : Section 11.5.2, 11.7.1"
+ ::= { mip6Notifications 3 }
+
+ mip6MnBindingExpiredAtHA NOTIFICATION-TYPE
+ OBJECTS {
+ mip6BindingTimeRegistered,
+ mip6BindingCOAType,
+ mip6BindingCOA
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent by a home agent when a
+ binding for the mobile node at the home agent
+ expired (no timely Binding Updates were received).
+ The MO instances in the notifications will be
+ identified by the mip6BindingHomeAddressType
+ and mip6BindingHomeAddress for the mobile node
+ in the mip6BindingCacheTable.
+ "
+ REFERENCE
+ "RFC 3775 : Section 10.3.2"
+ ::= { mip6Notifications 4 }
+
+
+
+
+Keeni, et al. Standards Track [Page 77]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnBindingExpiredAtCN NOTIFICATION-TYPE
+ OBJECTS {
+ mip6BindingTimeRegistered,
+ mip6BindingCOAType,
+ mip6BindingCOA
+ }
+ STATUS current
+ DESCRIPTION
+ "This notification is sent by a correspondent node
+ when a binding for the mobile node at the
+ correspondent node expired (no timely Binding
+ Updates were received).
+ The MO instances in the notifications will be
+ identified by the mip6BindingHomeAddressType
+ and mip6BindingHomeAddress for the mobile node
+ in the mip6BindingCacheTable.
+ "
+ ::= { mip6Notifications 5 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 78]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- Conformance information
+ mip6Groups OBJECT IDENTIFIER ::= { mip6Conformance 1 }
+ mip6Compliances OBJECT IDENTIFIER ::= { mip6Conformance 2 }
+
+ -- Units of conformance
+ mip6SystemGroup OBJECT-GROUP
+ OBJECTS {
+ mip6Capabilities,
+ mip6Status
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for basic MIPv6
+ monitoring."
+ ::= { mip6Groups 1 }
+
+ mip6BindingCacheGroup OBJECT-GROUP
+ OBJECTS {
+ mip6BindingCOAType,
+ mip6BindingCOA,
+ mip6BindingTimeRegistered,
+ mip6BindingTimeGranted,
+ mip6BindingTimeRemaining,
+ mip6BindingMaxSeq,
+ mip6BindingHomeRegn,
+ mip6BindingUsageTS,
+ mip6BindingUsageCount,
+ mip6BindingAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring the
+ Binding Cache.
+ "
+ ::= { mip6Groups 2 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 79]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingHstGroup OBJECT-GROUP
+ OBJECTS {
+ mip6BindingHstCOAType,
+ mip6BindingHstCOA,
+ mip6BindingHstTimeRegistered,
+ mip6BindingHstTimeExpired,
+ mip6BindingHstHomeRegn,
+ mip6BindingHstUsageTS,
+ mip6BindingHstUsageCount
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring the
+ Binding History. This can be used to monitor
+ the movement of the mobile node.
+ "
+ ::= { mip6Groups 3 }
+
+ mip6TotalTrafficGroup OBJECT-GROUP
+ OBJECTS {
+ mip6InOctets,
+ mip6HCInOctets,
+ mip6InPkts,
+ mip6HCInPkts,
+ mip6OutOctets,
+ mip6HCOutOctets,
+ mip6OutPkts,
+ mip6HCOutPkts,
+ mip6CounterDiscontinuityTime
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring the
+ total MIPv6 traffic.
+ "
+ ::= { mip6Groups 4 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 80]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6NodeTrafficGroup OBJECT-GROUP
+ OBJECTS {
+ mip6NodeInOctets,
+ mip6HCNodeInOctets,
+ mip6NodeInPkts,
+ mip6HCNodeInPkts,
+ mip6NodeOutOctets,
+ mip6HCNodeOutOctets,
+ mip6NodeOutPkts,
+ mip6HCNodeOutPkts,
+ mip6NodeCtrDiscontinuityTime
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring the
+ MIPv6 traffic due to a mobile node.
+ "
+ ::= { mip6Groups 5 }
+
+ mip6MnSystemGroup OBJECT-GROUP
+ OBJECTS {
+ mip6MnHomeAddressState
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for basic monitoring
+ of the mobile node.
+ "
+ ::= { mip6Groups 6 }
+
+ mip6MnConfGroup OBJECT-GROUP
+ OBJECTS {
+ mip6MnDiscoveryRequests,
+ mip6MnDiscoveryReplies,
+ mip6MnDiscoveryTimeouts,
+ mip6MnPrefixSolicitationsSent,
+ mip6MnPrefixAdvsRecd,
+ mip6MnPrefixAdvsIgnored,
+ mip6MnMovedToFN,
+ mip6MnMovedToHN
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ the advertisement-related info on the
+ mobile node.
+ "
+ ::= { mip6Groups 7 }
+
+
+
+Keeni, et al. Standards Track [Page 81]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6MnRegistrationGroup OBJECT-GROUP
+ OBJECTS {
+ mip6MnBLCOAType,
+ mip6MnBLCOA,
+ mip6MnBLLifeTimeRequested,
+ mip6MnBLLifeTimeGranted,
+ mip6MnBLMaxSeq,
+ mip6MnBLTimeSent,
+ mip6MnBLAccepted,
+ mip6MnBLAcceptedTime,
+ mip6MnBLRetransmissions,
+ mip6MnBLDontSendBUFlag,
+ --
+ -- Binding Update List
+ --
+ mip6MnMobilityMessagesSent,
+ mip6MnMobilityMessagesRecd,
+ mip6MnBUsToHA,
+ mip6MnBUAcksFromHA,
+ mip6MnBUsToCN,
+ mip6MnBUAcksFromCN,
+ mip6MnBindingErrorsFromCN,
+ mip6MnICMPErrorsRecd,
+ mip6MnBRRequestsRecd
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ the registration statistics for the mobile node.
+ "
+ ::= { mip6Groups 8 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 82]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnStatsGroup OBJECT-GROUP
+ OBJECTS {
+ mip6CnBURequestsAccepted,
+ mip6CnBURequestsRejected,
+ mip6CnBCEntryCreationTime,
+ mip6CnBUAcceptedTime,
+ mip6CnBURejectionTime,
+ mip6CnBURejectionCode,
+ mip6CnCtrDiscontinuityTime
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ the control messages and corresponding
+ statistics for each mobile node
+ communicating with the correspondent
+ node.
+ "
+ ::= { mip6Groups 9 }
+
+ mip6HaSystemGroup OBJECT-GROUP
+ OBJECTS {
+ mip6HaAdvsRecd,
+ mip6HaAdvsSent,
+ mip6HaAdvPreference,
+ mip6HaAdvLifetime,
+ mip6HaPrefixAdv,
+ mip6HaPrefixSolicitation,
+ mip6HaMCastCtlMsgSupport
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ the advertisement-related parameters and
+ statistics for the home agent.
+ "
+ ::= { mip6Groups 10 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 83]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaListGroup OBJECT-GROUP
+ OBJECTS {
+ mip6HaPreference,
+ mip6HaRecvLifeTime,
+ mip6HaRecvTimeStamp,
+ mip6HaGaGlobalAddressType,
+ mip6HaGaGlobalAddress
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ the Home Agent List on the home agent.
+ "
+ ::= { mip6Groups 11 }
+
+ mip6HaStatsGroup OBJECT-GROUP
+ OBJECTS {
+ mip6HaBURequestsAccepted,
+ mip6HaBURequestsDenied,
+ mip6HaBCEntryCreationTime,
+ mip6HaBUAcceptedTime,
+ mip6HaBURejectionTime,
+ mip6HaRecentBURejectionCode,
+ mip6HaCtrDiscontinuityTime
+
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ registration-related statistics on the home agent.
+ "
+ ::= { mip6Groups 12 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 84]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CnGlobalStatsGroup OBJECT-GROUP
+ OBJECTS {
+ mip6CnHomeTestInitsRecd,
+ mip6CnHomeTestsSent,
+ mip6CnCareOfTestInitsRecd,
+ mip6CnCareOfTestsSent,
+ mip6CnBUsRecd,
+ mip6CnBUAcksSent,
+ mip6CnBRsSent,
+ mip6CnBindingErrors,
+ mip6CnBUsAccepted,
+ mip6CnBUsRejected,
+ mip6CnReasonUnspecified,
+ mip6CnInsufficientResource,
+ mip6CnHomeRegnNotSupported,
+ mip6CnSeqNumberOutOfWindow,
+ mip6CnExpiredHomeNonceIndex,
+ mip6CnExpiredCareOfNonceIndex,
+ mip6CnExpiredNonce,
+ mip6CnRegTypeChangeDisallowed
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ advertisement and registration statistics on
+ a correspondent node.
+ "
+ ::= { mip6Groups 13 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 85]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaGlobalStatsGroup OBJECT-GROUP
+ OBJECTS {
+ mip6HaHomeTestInitsRecd,
+ mip6HaHomeTestsSent,
+ mip6HaBUsRecd,
+ mip6HaBUAcksSent,
+ mip6HaBRAdviceSent,
+ mip6HaBUsAccepted,
+ mip6HaPrefDiscoverReqd,
+ mip6HaReasonUnspecified,
+ mip6HaAdmProhibited,
+ mip6HaInsufficientResource,
+ mip6HaHomeRegnNotSupported,
+ mip6HaNotHomeSubnet,
+ mip6HaNotHomeAgentForThisMN,
+ mip6HaDupAddrDetectionFailed,
+ mip6HaSeqNumberOutOfWindow,
+ mip6HaExpiredHomeNonceIndex,
+ mip6HaRegTypeChangeDisallowed
+
+ }
+ STATUS current
+ DESCRIPTION
+ " A collection of objects for monitoring
+ advertisement and registration statistics on
+ a home agent.
+ "
+ ::= { mip6Groups 14 }
+
+ mip6BindingCacheCtlGroup OBJECT-GROUP
+ OBJECTS {
+ mip6BindingAdminStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects for controlling the
+ Binding Cache.
+ "
+ ::= { mip6Groups 15 }
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 86]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6NotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS {
+ mip6MnRegistered,
+ mip6MnDeRegistered,
+ mip6MnCOAChanged,
+ mip6MnBindingExpiredAtHA,
+ mip6MnBindingExpiredAtCN
+ }
+ STATUS current
+ DESCRIPTION
+ "A collection of notifications from a home agent
+ or correspondent node to the Manager about the
+ status of a mobile node.
+ "
+ ::= { mip6Groups 16 }
+
+
+
+ -- Compliance statements
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 87]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6CoreCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB.
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6SystemGroup }
+
+ ::= { mip6Compliances 1 }
+
+ mip6Compliance2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and support
+ monitoring of the Binding Cache and the Total
+ Traffic.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6SystemGroup,
+ mip6BindingCacheGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 2 }
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 88]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6Compliance3 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the Binding Cache,
+ the Binding History, the total traffic, and
+ the mobile node-wide traffic.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHstHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the
+ -- mip6BindingHstHomeAddress object.
+ --
+ -- OBJECT mip6BindingHstHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the
+ -- mip6BindingHstHomeAddress object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6SystemGroup,
+ mip6BindingCacheGroup,
+ mip6BindingHstGroup,
+ mip6TotalTrafficGroup,
+ mip6NodeTrafficGroup
+ }
+
+
+
+Keeni, et al. Standards Track [Page 89]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ ::= { mip6Compliances 3 }
+
+
+ mip6CoreReadOnlyCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode).
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6SystemGroup }
+
+ OBJECT mip6Status
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { mip6Compliances 4 }
+
+ mip6ReadOnlyCompliance2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode) and
+ support monitoring of the Binding Cache and Total
+ Traffic.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+
+
+
+Keeni, et al. Standards Track [Page 90]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ MANDATORY-GROUPS { mip6SystemGroup,
+ mip6BindingCacheGroup,
+ mip6TotalTrafficGroup
+ }
+ OBJECT mip6Status
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6BindingAdminStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { mip6Compliances 5 }
+
+ mip6ReadOnlyCompliance3 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode) and support
+ monitoring of the Binding Cache, the Binding History,
+ the total traffic, and the mobile node-wide traffic.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHstHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the
+ -- mip6BindingHstHomeAddress object.
+ --
+
+
+
+Keeni, et al. Standards Track [Page 91]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- OBJECT mip6BindingHstHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the
+ -- mip6BindingHstHomeAddress object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6SystemGroup,
+ mip6BindingCacheGroup,
+ mip6BindingHstGroup,
+ mip6TotalTrafficGroup,
+ mip6NodeTrafficGroup
+ }
+ OBJECT mip6Status
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6BindingAdminStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { mip6Compliances 6 }
+
+ mip6MnCoreCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the basic mobile node
+ functionality.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6MnHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6MnHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6MnHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+
+
+
+Keeni, et al. Standards Track [Page 92]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- ipv6 addresses for the mip6MnHomeAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6MnSystemGroup
+ }
+ ::= { mip6Compliances 7 }
+
+ mip6MnCompliance2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the mobile node
+ functionality specifically the Discovery- and
+ Registration-related statistics,
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6MnHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6MnHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6MnHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6MnHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6MnBLNodeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6MnBLNodeAddress
+ -- object.
+ --
+ -- OBJECT mip6MnBLNodeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6MnBLNodeAddress
+ -- object.
+
+
+
+Keeni, et al. Standards Track [Page 93]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6MnSystemGroup,
+ mip6MnConfGroup,
+ mip6MnRegistrationGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 8 }
+
+ mip6CnCoreCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the basic correspondent node
+ functionality.
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6CnGlobalStatsGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 9 }
+
+ mip6CnCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the basic correspondent node
+ functionality.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+
+
+
+Keeni, et al. Standards Track [Page 94]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6CnGlobalStatsGroup,
+ mip6CnStatsGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 10 }
+
+ mip6HaCoreCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the basic home agent
+ functionality.
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup
+ }
+ ::= { mip6Compliances 11 }
+
+ mip6HaCompliance2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring of the home agent
+ functionality specifically the Home Agent List
+ and the home-agent-registration-related statistics,
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddressType
+
+
+
+Keeni, et al. Standards Track [Page 95]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- SYNTAX InetAddressType { ipv6z(4) }
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddress
+ -- SYNTAX InetAddress (SIZE(20))
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup,
+ mip6HaListGroup,
+ mip6HaStatsGroup,
+ mip6HaGlobalStatsGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 12 }
+
+ mip6HaCompliance3 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support monitoring and control of the home agent
+ functionality specifically the Home Agent List
+ and the home-agent-registration-related statistics,
+
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+
+
+
+Keeni, et al. Standards Track [Page 96]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddressType
+ -- SYNTAX InetAddressType { ipv6z(4) }
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddress
+ -- SYNTAX InetAddress (SIZE(20))
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup,
+ mip6HaListGroup,
+ mip6HaStatsGroup,
+ mip6HaGlobalStatsGroup,
+ mip6BindingCacheCtlGroup,
+ mip6TotalTrafficGroup
+ }
+ ::= { mip6Compliances 13 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 97]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaCoreReadOnlyCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode) and
+ support monitoring of the basic home agent
+ functionality.
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup
+ }
+ OBJECT mip6HaAdvPreference
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaAdvLifetime
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixAdv
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixSolicitation
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaMCastCtlMsgSupport
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { mip6Compliances 14 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 98]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaReadOnlyCompliance2 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode) and
+ support monitoring of the home agent
+ functionality specifically the Home Agent List
+ and the home-agent-registration-related statistics.
+
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddressType
+ -- SYNTAX InetAddressType { ipv6z(4) }
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddress
+ -- SYNTAX InetAddress (SIZE(20))
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup,
+ mip6HaListGroup,
+ mip6HaStatsGroup,
+ mip6HaGlobalStatsGroup,
+
+
+
+Keeni, et al. Standards Track [Page 99]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6TotalTrafficGroup
+ }
+
+ OBJECT mip6HaAdvPreference
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaAdvLifetime
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixAdv
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixSolicitation
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaMCastCtlMsgSupport
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { mip6Compliances 15 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 100]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6HaReadOnlyCompliance3 MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB without support
+ for read-write (i.e., in read-only mode) and
+ support monitoring and control of the home agent
+ functionality specifically the Home Agent List
+ and the home-agent-registration-related statistics,
+
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddressType
+ -- SYNTAX InetAddressType { ipv6z(4) }
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ -- OBJECT mip6HaLinkLocalAddress
+ -- SYNTAX InetAddress (SIZE(20))
+ -- DESCRIPTION
+ -- This MIB module requires support for local
+ -- ipv6 addresses for the mip6HaLinkLocalAddress
+ -- object.
+ --
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6HaSystemGroup,
+ mip6HaListGroup,
+ mip6HaStatsGroup,
+ mip6HaGlobalStatsGroup,
+
+
+
+Keeni, et al. Standards Track [Page 101]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ mip6BindingCacheCtlGroup,
+ mip6TotalTrafficGroup
+ }
+
+ OBJECT mip6HaAdvPreference
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaAdvLifetime
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixAdv
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaPrefixSolicitation
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6HaMCastCtlMsgSupport
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT mip6BindingAdminStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { mip6Compliances 16 }
+
+ mip6NotificationCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMP entities
+ that implement the MOBILEIPV6-MIB and
+ support Notification from home agent or
+ correspondent node to management stations
+ about the mobile node status.
+ There are a number of INDEX objects that cannot be
+ represented in the form of OBJECT clauses in SMIv2,
+ but for which there are compliance requirements,
+ expressed in OBJECT clause form in this description:
+
+
+
+Keeni, et al. Standards Track [Page 102]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ -- OBJECT mip6BindingHomeAddressType
+ -- SYNTAX InetAddressType { ipv6(2) }
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ --
+ -- OBJECT mip6BindingHomeAddress
+ -- SYNTAX InetAddress (SIZE(16))
+ -- DESCRIPTION
+ -- This MIB module requires support for global
+ -- ipv6 addresses for the mip6BindingHomeAddress
+ -- object.
+ "
+ MODULE -- this module
+ MANDATORY-GROUPS { mip6NotificationGroup
+ }
+ ::= { mip6Compliances 17 }
+
+ END
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 103]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+6. Security Considerations
+
+ There are a number of management objects defined in this MIB module
+ with a MAX-ACCESS clause of read-write. Such objects may be
+ considered sensitive or vulnerable in some network environments. The
+ support for SET operations in a non-secure environment without proper
+ protection can have a negative effect on network operations. These
+ are the tables and objects and the corresponding
+ sensitivity/vulnerability:
+
+ mip6Status: The value of this object is used to enable or
+ disable the MIPv6 functionality on a MIPv6 entity.
+ Access to this MO may be abused to disrupt the
+ MIPv6 communication.
+ mip6HaAdvPreference: Access to this object may be abused to
+ force MNs into selecting the wrong HA.
+ mip6HaAdvLifetime: Access to this object may be abused to set
+ the advertised lifetime to incorrect values. That
+ will have an adverse impact on the MIPv6
+ communication.
+ mip6BindingAdminStatus: The value of this object is used to
+ control the status of a Binding Cache entry.
+ Access to this object may be abused to deny Mobile
+ IPv6 connectivity to a legitimate user or to
+ grant Mobile IPv6 connectivity to an illegal user.
+ mip6HaPrefixAdv: The value of this object indicates whether
+ the home agent will send ICMP Mobile Prefix
+ Advertisements to the mobile node.
+ Access to this object may be abused to send
+ unwanted/wrong prefix information or to deny the
+ mobile node from receiving information about the
+ changes in the home prefixes.
+ This may result in disruption of the Mobile IPv6
+ connectivity.
+ mip6HaPrefixSolicitation: The value of this object indicates
+ whether the home agent should respond to ICMP
+ Mobile Prefix Solicitation messages from a mobile
+ node. Access to this object may be abused to deny
+ the mobile node information about its home prefix.
+ This may result in disruption of the Mobile IPv6
+ connectivity.
+ mip6HaMCastCtlMsgSupport: The value of this object decides
+ whether the home agent should process the
+ multicast group membership control messages it
+ receives from mobile nodes. Access to this object
+ may be used to subvert administrate policy on
+ multicasting or to disrupt the multicast
+ communication with the mobile node.
+
+
+
+Keeni, et al. Standards Track [Page 104]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ Some of the readable objects in this MIB module (i.e., objects with a
+ MAX-ACCESS other than not-accessible) may be considered sensitive or
+ vulnerable in some network environments. It is thus important to
+ control even GET and/or NOTIFY access to these objects and possibly
+ to even encrypt the values of these objects when sending them over
+ the network via SNMP. These are the tables and objects and their
+ sensitivity/vulnerability:
+
+ The address-related objects in this MIB may be considered to be
+ particularly sensitive and/or private. The care-of-address-related
+ objects reveal the location and movement of the mobile node. This
+ information may be considered to be private and sensitive and must
+ be carefully handled.
+ mip6BindingHstCOAType
+ mip6BindingHstCOA
+ mip6MnBLCOAType
+ mip6MnBLCOA
+
+ The mobile node's home-address- and home-agent-related information
+ may be considered to be sensitive too as these may provide clues to
+ a malicious party on ways to disrupt the mobile nodes communication
+ channels.
+ mip6BindingHstHomeAddressType,
+ mip6BindingHstHomeAddress,
+ mip6MnHomeAddressType,
+ mip6MnHomeAddress
+
+ The correspondent node's address-related MOs will reveal the nodes
+ with whom the mobile node is corresponding. This information may be
+ considered private and sensitive.
+ mip6MnBLNodeAddressType,
+ mip6MnBLNodeAddress
+
+
+ SNMP versions prior to SNMPv3 did not include adequate security.
+ Even if the network itself is secure (for example by using IPSec),
+ even then, there is no control as to who on the secure network is
+ allowed to access and GET/SET (read/change/create/delete) the objects
+ in this MIB module.
+
+ It is RECOMMENDED that implementors consider the security features as
+ provided by the SNMPv3 framework (see [RFC3410], section 8),
+ including full support for the SNMPv3 cryptographic mechanisms (for
+ authentication and privacy).
+
+ Further, deployment of SNMP versions prior to SNMPv3 is NOT
+ RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
+ enable cryptographic security. It is then a customer/operator
+
+
+
+Keeni, et al. Standards Track [Page 105]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+ responsibility to ensure that the SNMP entity giving access to an
+ instance of this MIB module is properly configured to give access to
+ the objects only to those principals (users) that have legitimate
+ rights to indeed GET or SET (change/create/delete) them.
+
+7. IANA Considerations
+
+ IANA has assigned a base arc in the 'mib-2' (standards track) OID
+ tree for the 'mip6MIB' MODULE-IDENTITY defined in the Mobile-IPv6
+ MIB. The mib-2 number is 133 for mip6MIB.
+
+8. References
+
+8.1. Normative References
+
+ [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
+ Requirements Levels", BCP 14, RFC 2119, March 1997.
+
+ [RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
+ J., Rose, M., and S. Waldbusser, "Structure of
+ Management Information Version 2 (SMIv2)", STD 58, RFC
+ 2578, April 1999.
+
+ [RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
+ J., Rose, M., and S. Waldbusser, "Textual Conventions
+ for SMIv2", STD 58, RFC 2579, April 1999.
+
+ [RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
+ J., Rose, M., and S. Waldbusser, "Conformance Statements
+ for SMIv2", STD 58, RFC 2580, April 1999.
+
+ [RFC3775] Johnson, D., Perkins, C., and Arkko J., Mobility Support
+ in IPv6" RFC 3775, June 2004.
+
+ [RFC4293] Routhier, S., Ed., "Management Information Base for the
+ Internet Protocol (IP)", RFC 4293, April 2006.
+
+ [RFC4001] Daniele, M., Haberman, B., Routhier, S., and J.
+ Schoenwaelder, "Textual Conventions for Internet Network
+ Addresses", RFC 4001, February 2005.
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 106]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+8.2. Informative References
+
+ [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
+ "Introduction and Applicability Statements for
+ Internet-Standard Management Framework", RFC 3410,
+ December 2002.
+
+ [RFC4087] Thaler, D., "IP Tunnel MIB", RFC 4087, June 2005.
+
+9. Acknowledgements
+
+ The following groups and individuals have contributed to this
+ document with discussions and comments:
+
+ WIDE-netman group
+ C.M. Heard
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 107]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+Authors' Addresses
+
+ Glenn Mansfield Keeni
+ Cyber Solutions Inc.
+ 6-6-3 Minami Yoshinari
+ Aoba-ku, Sendai 989-3204
+ Japan
+
+ Phone: +81-22-303-4012
+ EMail: glenn@cysols.com
+
+
+ Kenichi Nagami
+ INTEC NetCore Inc.
+ 1-3-3, Shin-suna
+ Koto-ku, Tokyo, 135-0075
+ Japan
+
+ Phone: +81-3-5665-5069
+ EMail: nagami@inetcore.com
+
+
+ Kazuhide Koide
+ Tohoku University
+ 2-1-1, Katahira
+ Aoba-ku, Sendai, 980-8577
+ Japan
+
+ Phone: +81-22-217-5454
+ EMail: koide@shiratori.riec.tohoku.ac.jp
+
+
+ Sri Gundavelli
+ Cisco Systems
+ 170 W.Tasman Drive,
+ San Jose, CA 95134
+ USA
+
+ Phone: +1-408-527-6109
+ EMail: sgundave@cisco.com
+
+
+
+
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 108]
+
+RFC 4295 MOBILEIPV6-MIB April 2006
+
+
+Full Copyright Statement
+
+ Copyright (C) The Internet Society (2006).
+
+ This document is subject to the rights, licenses and restrictions
+ contained in BCP 78, and except as set forth therein, the authors
+ retain all their rights.
+
+ This document and the information contained herein are provided on an
+ "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
+ OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
+ ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
+ INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
+ INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
+ WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
+
+Intellectual Property
+
+ The IETF takes no position regarding the validity or scope of any
+ Intellectual Property Rights or other rights that might be claimed to
+ pertain to the implementation or use of the technology described in
+ this document or the extent to which any license under such rights
+ might or might not be available; nor does it represent that it has
+ made any independent effort to identify any such rights. Information
+ on the procedures with respect to rights in RFC documents can be
+ found in BCP 78 and BCP 79.
+
+ Copies of IPR disclosures made to the IETF Secretariat and any
+ assurances of licenses to be made available, or the result of an
+ attempt made to obtain a general license or permission for the use of
+ such proprietary rights by implementers or users of this
+ specification can be obtained from the IETF on-line IPR repository at
+ http://www.ietf.org/ipr.
+
+ The IETF invites any interested party to bring to its attention any
+ copyrights, patents or patent applications, or other proprietary
+ rights that may cover technology that may be required to implement
+ this standard. Please address the information to the IETF at
+ ietf-ipr@ietf.org.
+
+Acknowledgement
+
+ Funding for the RFC Editor function is provided by the IETF
+ Administrative Support Activity (IASA).
+
+
+
+
+
+
+
+Keeni, et al. Standards Track [Page 109]
+