1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
|
Network Working Group J. Hilgeman, Chair
Request for Comments: 1747 Apertus Technologies, Inc.
Category: Standards Track S. Nix
Metaplex, Inc.
A. Bartky
Sync Research, Inc.
W. Clark, Editor
cisco Systems, Inc.
January 1995
Definitions of Managed Objects for SNA Data Link Control (SDLC)
using SMIv2
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Abstract
This specification defines an extension to the Management Information
Base (MIB) for use with SNMP-based network management. In
particular, it defines objects for managing the configuration,
monitoring and control of data link controls in an SNA environment.
This draft identifies managed objects for SNA Synchronous Data Link
Control (SDLC) links only.
Table of Contents
1. The SNMPv2 Network Management Framework ................. 2
1.1 Object Definitions .................................... 2
2. Overview ................................................ 2
2.1 Tables Defined in the SNADLC SDLC MIB ................. 3
2.2 Row Creation Mechanism ................................ 3
2.3 Relationship to the Interfaces Group .................. 4
3. Definitions ............................................. 7
3.1 Port Administrative Table ............................. 9
3.2 Port Operational Table ............................... 14
3.3 Port Statistics Table ................................ 20
3.4 Link Station Administrative Table .................... 26
3.5 Link Station Operational Table ....................... 35
3.6 Link Station Statistics Table ........................ 44
3.7 Trap Definitions ..................................... 56
3.8 Compliance Statements ................................ 57
Hilgeman, Nix, Bartky & Clark [Page 1]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
4. Acknowledgments ........................................ 65
5. References ............................................. 65
6. Glossary ............................................... 66
7. Security Considerations ................................ 67
8. Authors' Addresses ..................................... 67
1. The SNMPv2 Network Management Framework
The SNMPv2 Network Management Framework consists of four major
components. They are:
o RFC 1441 which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of management.
o STD 17, RFC 1213 defines MIB-II, the core set of managed
objects for the Internet suite of protocols.
o RFC 1445 which defines the administrative and other
architectural aspects of the framework.
o RFC 1448 which defines the protocol used for network access
to managed objects.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
1.1. Object Definitions
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1)
defined in the SMI. In particular, each object object type is named
by an OBJECT IDENTIFIER, an administratively assigned name. The
object type together with an object instance serves to uniquely
identify a specific instantiation of the object. For human
convenience, we often use a textual string, termed the descriptor, to
refer to the object type.
2. Overview
This memo identifies the proposed set of objects for configuring,
monitoring, and controlling SDLC ports and link stations.
Hilgeman, Nix, Bartky & Clark [Page 2]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
2.1. Tables Defined in the SNADLC SDLC MIB
The SNADLC MIB is composed of two managed entities with three tables
each. The two managed entities for SDLC are:
o Ports: the physical connection, and
o Link Stations: the logical connections on the Port.
The three management tables are:
o Adminstration: objects used for configuring and controlling
the operation of a Port or Link Station,
o Operational: objects that reflect the run-time state of the
Port or Link Station, and
o Statistics: objects that reflect the operating metrics of the
Port or Link Station.
Considering the above combinations, the following are the actual
tables found in this MIB:
1) Port Administration Table,
2) Port Operation Table,
3) Port Statistics Table,
4) Link Station Administration Table,
5) Link Station Operation Table,
6) Link Station Statistics Table.
All variables in this MIB relate to SDLC ports and link stations
only. Any variable relating to higher-layer entities in SNA such as
Physical Units (PU) and Logical Units (LU) are found in the SNA NAU
MIB [4].
2.2. Row Creation Mechanism
Row creation mechanism for the sdlcLSAdminTable is based on the use
of the RowStatus object. It follows the rules for the use in SNMPv1
context proposed in the memo "Row creation with SNMPv1" [5]. Before
accepting the destroy value for an entry, an agent has to verify the
operational state of the corresponding entry in the sdlcLSOperTable
entry.
Hilgeman, Nix, Bartky & Clark [Page 3]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
2.3. Relationship to the Interfaces Group
This memo shall conform to the recommendations of [6].
The SDLC layer of each SDLC Port shall be modeled by a row in the
ifTable with an ifType using the IANA assigned number for SDLC (17).
Each SDLC port interface must comply with the following conformance
groups in [6]:
- ifGeneralGroup
- ifStackGroup
- ifPacketGroup
An implementation may optionally comply with the ifTestGroup defined
in that memo to execute vendor specific tests. An example of this
would be to perform LPDA test functions.
The SDLC port's relation with its physical, or lower-layer interface
(i.e., RS-232, V.35, etc.) shall be modeled by a row in the
ifStackTable with the ifStackHigherLayer pointing to the SDLC port
ifTable instance and the ifStackLowerLayer pointing to the physical
media-specific ifTable instance. The media-specific objects of these
lower-layer interfaces will, of course, be described in their
respective MIBs (i.e., [1]).
The following table provides specific implementation guidelines for
all the interface group objects listed in the conformance tables
above.
Object Use for an SDLC Port
ifIndex Each SDLC port is represented by an ifEntry. All
SDLC port tables shall be indexed by ifIndex.
ifDescr Description of the SDLC port.
ifType The IANA value reserved for SDLC - 17.
ifMtu Refer to [6].
ifSpeed This object shall reflect the value of the
corresponding object in the ifEntry of the
associated lower-layer interface.
ifPhysAddress A string denoting the physical location of the SDLC
port within its node. This shall have unique
significance within each implementing node.
Hilgeman, Nix, Bartky & Clark [Page 4]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
ifAdminStatus This object shall reflect the value of the
corresponding object in the ifEntry of the
associated lower-layer interface.
ifOperStatus This object shall reflect the value of the
corresponding object in the ifEntry of the
associated lower-layer interface.
ifLastChange Refer to [6].
ifInOctets Refer to [6].
ifInUcastPkts This object shall count packets received from a
specific SDLC poll address. Packets for the SDLC
broadcast address of x'FF' are not counted.
ifInDiscards Refer to [6].
ifInErrors Refer to [6]. Specific counters for these errors
are kept in the sdlcPortStatsTable.
ifInUnknownProtos This counter shall return zero for SDLC ports.
ifOutOctets Refer to [6].
ifOutUcastPkts This object shall count packets transmitted to a
specific SDLC poll address (not x'FF').
ifOutDiscards Refer to [6].
ifOutErrors Refer to [6]. Specific counters for these errors
are kept in the sdlcPortStatsTable.
ifName The textual name of the SDLC port or an octet string
of zero length.
ifInMulticastPkts The value is 0 (not applicable to the SDLC layer).
ifInBroadcastPkts This object shall count packets received on this
interface addressed to the SDLC broadcast address
(x'FF'). Only point-to-point ports supporting a
secondary switched station should return non-zero
values.
ifOutMulticastPkts The value is 0 (not applicable to the SDLC layer).
ifOutBroadcastPkts This object shall count packets transmitted on this
interface which were addressed to the SDLC broadcast
Hilgeman, Nix, Bartky & Clark [Page 5]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
address (x'FF'). Only point-to-point ports
supporting a primary switched station should
return non-zero values.
ifHC* Not part of the conformance group.
ifLinkUpDownTrapEnable
Refer to [6]. Default is disabled (2).
ifHighSpeed Refer to [6].
ifPromiscuousMode Should return false if this interface receives only
packets addressed to its SDLC poll address(es).
However, in certain implementations, the lower-layer
interface shall present all frames to the SDLC port
regardless of the poll address. Such frames may be
the result of a misconfigured peer or the secondary
end of a multipoint connection. Such
implementations should return true for this
object.
ifConnectorPresent Set to 'false'.
ifStackHigherLayer For each SDLC port there will be an ifStackEntry
with this object's value referring to the ifIndex of
the SDLC port's ifEntry for the SDLC layer.
ifStackLowerLayer For each SDLC port there will be an ifStackEntry
with this object's value referring to the ifIndex of
the physical layer interface's ifEntry for that SDLC
port.
ifStackStatus Refer to [6].
Hilgeman, Nix, Bartky & Clark [Page 6]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
3. Definitions
SNA-SDLC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Counter32, Integer32, TimeTicks
FROM SNMPv2-SMI
DisplayString, RowStatus, TimeInterval
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
mib-2, ifIndex, ifAdminStatus, ifOperStatus
FROM RFC1213-MIB;
snaDLC MODULE-IDENTITY
LAST-UPDATED "9411150000Z"
ORGANIZATION "IETF SNA DLC MIB Working Group"
CONTACT-INFO
" Wayne Clark
Postal: cisco Systems, Inc.
3100 Smoketree Ct.
Suite 1000
Raleigh, NC 27604
US
Tel: +1 919 878 6958
E-Mail: wclark@cisco.com"
DESCRIPTION
"This is the MIB module for objects used to
manage SDLC devices."
::= { mib-2 41 }
--
-- The following data link controls are modelled in this MIB module:
--
-- 1. SDLC
--
sdlc OBJECT IDENTIFIER ::= { snaDLC 1 }
Hilgeman, Nix, Bartky & Clark [Page 7]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
--
-- THE SDLC GROUP
-- ==============
--
-- The following resources are modelled in the SDLC group of this
-- MIB module:
--
-- 1. PORTS
-- 2. LINK STATIONS
sdlcPortGroup OBJECT IDENTIFIER ::= { sdlc 1 } -- Physical Ports
sdlcLSGroup OBJECT IDENTIFIER ::= { sdlc 2 } -- Logical Link Stations
--
-- THE SDLC PORT GROUP
-- ===================
--
-- The following classes of information is modelled for each SDLC port:
--
-- 1. ADMINISTRATIVE ( read/write)
-- 2. OPERATIONAL ( read-only)
-- 3. STATISTICS ( read-only)
-- Information not found in this group is found in tables described in
-- the following RFCs:
--
-- 1. RFC1213 - MIB-II
--
-- TABLE INDEX
-- ==================== ====================
-- a. ifTable ifIndex
--
-- 2. RFC1659 - The RS232-like MIB
--
-- TABLE INDEX
-- ==================== ====================
-- a. rs232PortTable rs232PortIndex
-- b. rs232SyncPortTable rs232SyncPortIndex
-- c. rs232InSigTable rs232InSigPortIndex,
-- rs232InSigName
-- d. rs232OutSigTable rs232OutSigPortIndex,
-- rs232OutSigName
-- ** e. rs232AsyncPortTable rs232AsyncPortIndex
--
-- ** rs232AsyncPortTable for ISO 3309.3 ( Start-Stop SDLC).
Hilgeman, Nix, Bartky & Clark [Page 8]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-- *************************************************************
-- * *
-- * THE SDLC PORT ADMINISTRATIVE TABLE *
-- * *
-- *************************************************************
sdlcPortAdminTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcPortAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects that can be
changed to manage an SDLC port. Changing one
of these parameters may take effect in the
operating port immediately or may wait until
the interface is restarted depending on the
details of the implementation.
Most of the objects in this read-write table
have corresponding read-only objects in the
sdlcPortOperTable that return the current
operating value.
The operating values may be different from
these configured values if a configured
parameter was changed after the interface was
started."
::= { sdlcPortGroup 1 }
sdlcPortAdminEntry OBJECT-TYPE
SYNTAX SdlcPortAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of configured values for an SDLC port."
INDEX { ifIndex }
::= { sdlcPortAdminTable 1 }
SdlcPortAdminEntry ::= SEQUENCE
{
sdlcPortAdminName DisplayString,
sdlcPortAdminRole INTEGER,
sdlcPortAdminType INTEGER,
sdlcPortAdminTopology INTEGER,
sdlcPortAdminISTATUS INTEGER,
sdlcPortAdminACTIVTO TimeInterval,
sdlcPortAdminPAUSE TimeInterval,
sdlcPortAdminSERVLIM Integer32,
Hilgeman, Nix, Bartky & Clark [Page 9]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcPortAdminSlowPollTimer TimeInterval
}
sdlcPortAdminName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An octet string that defines the physical port
to which this interface is assigned. It has
implementation-specific significance. Its value
shall be unique within the administered
system. It must contain only ASCII printable
characters. Should an implementation choose to
accept a write operation for this object, it
causes the logical port definition associated
with the table instance to be moved to a
different physical port. A write operation
shall not take effect until the port is cycled
inactive."
::= { sdlcPortAdminEntry 1 }
sdlcPortAdminRole OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
secondary(2),
negotiable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the role that the link
station shall assume the next time a connection
is established.
Even though this is defined as a port object,
it is a link station attribute in the sense
that a role is per link station. However, it
is not possible to vary link station roles on a
particular port. For example, if an SDLC port
is configured to primary, all link stations on
that port must be primary."
::= { sdlcPortAdminEntry 2 }
sdlcPortAdminType OBJECT-TYPE
SYNTAX INTEGER
{
Hilgeman, Nix, Bartky & Clark [Page 10]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
leased(1),
switched(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether the SDLC port
is to connect to a leased or switched line. A
write operation to this administrative value
shall not take effect until the SDLC port has
been cycled inactive."
DEFVAL { leased }
::= { sdlcPortAdminEntry 3 }
sdlcPortAdminTopology OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint(1),
multipoint(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether the SDLC port is
capable of operating in either a point-to-point
or multipoint topology.
sdlcPortAdminTopology == multipoint implies the
port can also operate in a point-to-point
topology. sdlcPortAdminTopology ==
pointToPoint does not imply the port can
operate in a multipoint topology.
A write operation to this administrative value
shall not take effect until the SDLC port has
been cycled inactive."
DEFVAL { pointToPoint }
::= { sdlcPortAdminEntry 4 }
sdlcPortAdminISTATUS OBJECT-TYPE
SYNTAX INTEGER
{
inactive(1),
active(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 11]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"This parameter controls the initial value of
the administrative status, ifAdminStatus, of
this SDLC port at port start-up. Depending
on the implementation, a write operation to
this administrative object may not take effect
until the SDLC port has been cycled inactive."
DEFVAL { active }
::= { sdlcPortAdminEntry 5 }
sdlcPortAdminACTIVTO OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the period of time (in
1/100ths of a second) that the port will allow a
switched line to remain inactive before
disconnecting. A switched line is considered
to be inactive if there are no I-Frames being
transferred. A value of zero indicates no
timeout. Depending on the implementation, a
write operation to this administered value may
not take effect until the port is cycled
inactive.
This object only has meaning for SDLC ports
where sdlcPortAdminType == switched
The object descriptor contains the name of an
NCP configuration parameter, ACTIVTO. Please
note that the value of this object represents
1/100ths of a second while the NCP ACTIVTO is
represented in seconds."
DEFVAL { 0 }
::= { sdlcPortAdminEntry 6 }
sdlcPortAdminPAUSE OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the minimum elapsed time
(in 1/100ths of a second) between any two
traversals of the poll list for a primary SDLC
port. Depending on the implementation, a write
operation to this administered value may not
take effect until the port is cycled inactive.
Hilgeman, Nix, Bartky & Clark [Page 12]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
The object descriptor contains the name of an
NCP configuration parameter, PAUSE. Please
note that the value of this object represents
1/100ths of a second while the NCP PAUSE is
represented in 1/10ths of a second.
This object only has meaning for SDLC ports
where sdlcPortAdminRole == primary "
DEFVAL { 200 }
::= { sdlcPortAdminEntry 7 }
sdlcPortAdminSERVLIM OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of times the
active poll list will be traversed before
polling a station on the slow poll list for a
primary, multipoint SDLC port. Depending on
the implementation, a write operation to this
administered value may not take effect until
the port is cycled inactive.
This object only has meaning for SDLC ports
where
sdlcPortAdminRole == primary
and
sdlcPortAdminTopology == multipoint "
DEFVAL { 20 }
::= { sdlcPortAdminEntry 8 }
sdlcPortAdminSlowPollTimer OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the elapsed time (in
1/100ths of a second) between polls for failed
secondary link station addresses. Depending
on the implementation, a write operation to
this administered value may not take effect
until the port is cycled inactive.
This object only has meaning for SDLC ports
where
sdlcPortAdminRole == primary
and
Hilgeman, Nix, Bartky & Clark [Page 13]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcPortAdminTopology == multipoint "
DEFVAL { 2000 }
::= { sdlcPortAdminEntry 9 }
-- *************************************************************
-- * *
-- * THE SDLC PORT OPERATIONAL TABLE *
-- * *
-- *************************************************************
sdlcPortOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcPortOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains current SDLC port
parameters. Many of these objects have
corresponding objects inthe sdlcPortAdminTable."
::= { sdlcPortGroup 2 }
sdlcPortOperEntry OBJECT-TYPE
SYNTAX SdlcPortOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Currently set parameters for a specific SDLC
port."
INDEX { ifIndex }
::= { sdlcPortOperTable 1 }
SdlcPortOperEntry ::= SEQUENCE
{
sdlcPortOperName DisplayString,
sdlcPortOperRole INTEGER,
sdlcPortOperType INTEGER,
sdlcPortOperTopology INTEGER,
sdlcPortOperISTATUS INTEGER,
sdlcPortOperACTIVTO TimeInterval,
sdlcPortOperPAUSE TimeInterval,
sdlcPortOperSlowPollMethod INTEGER,
sdlcPortOperSERVLIM Integer32,
sdlcPortOperSlowPollTimer TimeInterval,
sdlcPortOperLastModifyTime TimeTicks,
sdlcPortOperLastFailTime TimeTicks,
sdlcPortOperLastFailCause INTEGER
}
sdlcPortOperName OBJECT-TYPE
Hilgeman, Nix, Bartky & Clark [Page 14]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
SYNTAX DisplayString (SIZE (1..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An octet string that describes the physical
port to which this interface is currently
attached. It has implementation-specific
significance."
::= { sdlcPortOperEntry 1 }
sdlcPortOperRole OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
secondary(2),
undefined(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the role that the link
station has assumed on this connection.
Even though this is defined as a port object,
it is a link station attribute in the sense
that a role is per link station. However, it
is not possible to vary link station roles on a
particular port. For example, if an SDLC port
is configured to primary, all link stations on
that port must be primary.
The value of sdlcPortOperRole is undefined(3)
whenever the link station role has not yet been
established by the mode setting command."
::= { sdlcPortOperEntry 2 }
sdlcPortOperType OBJECT-TYPE
SYNTAX INTEGER
{
leased(1),
switched(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines whether the SDLC port
is currently operating as though connected to a
leased or switched line."
Hilgeman, Nix, Bartky & Clark [Page 15]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
::= { sdlcPortOperEntry 3 }
sdlcPortOperTopology OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint(1),
multipoint(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines whether the SDLC port is
currently operating in a point-to-point or
multipoint topology."
::= { sdlcPortOperEntry 4 }
sdlcPortOperISTATUS OBJECT-TYPE
SYNTAX INTEGER
{
inactive(1),
active(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter describes the initial value of
the administrative status, ifAdminStatus, of
this SDLC port at last port start-up."
::= { sdlcPortOperEntry 5 }
sdlcPortOperACTIVTO OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines the period of time (in
100ths of a second) that the port will allow a
switched line to remain inactive before
disconnecting. A switched line is considered
to be inactive if there are no I-Frames being
transferred.
The object descriptor contains the name of an
NCP configuration parameter, ACTIVTO. Please
note that the value of this object represents
1/100ths of a second while the NCP ACTIVTO is
represented in seconds.
Hilgeman, Nix, Bartky & Clark [Page 16]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
A value of zero indicates no timeout."
::= { sdlcPortOperEntry 6 }
sdlcPortOperPAUSE OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the current minimum
elapsed time (in 1/100ths of a second) between
any two traversals of the poll list for a
primary SDLC port.
The object descriptor contains the name of an
NCP configuration parameter, PAUSE. Please
note that the value of this object represents
1/100ths of a second while the NCP PAUSE is
represented in 1/10ths of a second.
This object only has meaning for SDLC ports
where
sdlcPortAdminRole == primary "
::= { sdlcPortOperEntry 7 }
sdlcPortOperSlowPollMethod OBJECT-TYPE
SYNTAX INTEGER
{
servlim(1),
pollpause(2),
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the exact method that is in
effect for periodically polling failed secondary
link station addresses.
If sdlcPortOperSlowPollMethod == servlim, then
sdlcPortOperSERVLIM defines the actual polling
characteristics.
If sdlcPortOperSlowPollMethod == pollpause,
then sdlcPortOperSlowPollTimer defines the
actual polling characteristics.
If sdlcPortOperSlowPollMethod == other, then
the polling characteristics are modeled in
Hilgeman, Nix, Bartky & Clark [Page 17]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
vendor-specific objects.
This object only has meaning for SDLC ports
where
sdlcPortOperRole == primary
and
sdlcPortOperTopology == multipoint "
::= { sdlcPortOperEntry 8 }
sdlcPortOperSERVLIM OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the number of times the
active poll list is currently being traversed
before polling a station on the slow poll list
for a primary, multipoint SDLC port.
This object only has meaning for SDLC ports
where
sdlcPortOperRole == primary
and
sdlcPortOperTopology == multipoint "
::= { sdlcPortOperEntry 9 }
sdlcPortOperSlowPollTimer OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the elapsed time (in
1/100ths of a second) between polls for failed
secondary link station addresses.
This object only has meaning for SDLC ports
where
sdlcPortOperRole == primary
and
sdlcPortOperTopology == multipoint "
::= { sdlcPortOperEntry 10 }
sdlcPortOperLastModifyTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the value of sysUpTime
Hilgeman, Nix, Bartky & Clark [Page 18]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
when this port definition was last modified.
If the port has not been modified, then this
value shall be zero."
::= { sdlcPortOperEntry 11 }
sdlcPortOperLastFailTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the value of sysUpTime
when this SDLC port last failed. If the port
has not failed, then this value shall be zero."
::= { sdlcPortOperEntry 12 }
sdlcPortOperLastFailCause OBJECT-TYPE
SYNTAX INTEGER
{
undefined(1),
physical(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This enumerated object describes the cause of
the last failure of this SDLC port. If the
port has not failed, then this object has a
value of undefined(1)."
DEFVAL { undefined }
::= { sdlcPortOperEntry 13 }
Hilgeman, Nix, Bartky & Clark [Page 19]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-- *************************************************************
-- * *
-- * THE SDLC PORT STATISTICS TABLE *
-- * *
-- *************************************************************
sdlcPortStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table contains statistics
for a specific SDLC port."
::= { sdlcPortGroup 3 }
sdlcPortStatsEntry OBJECT-TYPE
SYNTAX SdlcPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of statistics for an SDLC port."
INDEX { ifIndex }
::= { sdlcPortStatsTable 1 }
SdlcPortStatsEntry ::= SEQUENCE
{
sdlcPortStatsPhysicalFailures Counter32,
sdlcPortStatsInvalidAddresses Counter32,
sdlcPortStatsDwarfFrames Counter32,
sdlcPortStatsPollsIn Counter32,
sdlcPortStatsPollsOut Counter32,
sdlcPortStatsPollRspsIn Counter32,
sdlcPortStatsPollRspsOut Counter32,
sdlcPortStatsLocalBusies Counter32,
sdlcPortStatsRemoteBusies Counter32,
sdlcPortStatsIFramesIn Counter32,
sdlcPortStatsIFramesOut Counter32,
sdlcPortStatsOctetsIn Counter32,
sdlcPortStatsOctetsOut Counter32,
sdlcPortStatsProtocolErrs Counter32,
sdlcPortStatsActivityTOs Counter32,
sdlcPortStatsRNRLIMITs Counter32,
sdlcPortStatsRetriesExps Counter32,
sdlcPortStatsRetransmitsIn Counter32,
sdlcPortStatsRetransmitsOut Counter32
}
sdlcPortStatsPhysicalFailures OBJECT-TYPE
Hilgeman, Nix, Bartky & Clark [Page 20]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of times
this port has failed due to its physical media
since port startup. At port startup time,
this object must be initialized to zero."
::= { sdlcPortStatsEntry 1 }
sdlcPortStatsInvalidAddresses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
frames received by this port with invalid link
station addresses."
::= { sdlcPortStatsEntry 2 }
sdlcPortStatsDwarfFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
frames received by this port which were
delivered intact by the physical layer but were
too short to be legal.
Ignoring the frame check sequence (FCS), a
frame is considered to be too short if it
is less than 2 bytes for sdlcLSOperMODULO of
eight, or if it is less than 3 bytes for
sdlcLSOperMODULO of onetwentyeight."
::= { sdlcPortStatsEntry 3 }
sdlcPortStatsPollsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of polls
received by this port since the port was
created."
::= { sdlcPortStatsEntry 4 }
Hilgeman, Nix, Bartky & Clark [Page 21]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcPortStatsPollsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of polls
sent by this port since the port was created."
::= { sdlcPortStatsEntry 5 }
sdlcPortStatsPollRspsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of poll
responses received by this port since the port
was created."
::= { sdlcPortStatsEntry 6 }
sdlcPortStatsPollRspsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of poll
responses sent by this port since the port was
created."
::= { sdlcPortStatsEntry 7 }
sdlcPortStatsLocalBusies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
times that the local SDLC link stations on
this port have entered a busy state (RNR).
This object is initialized to zero when the
port is created."
::= { sdlcPortStatsEntry 8 }
sdlcPortStatsRemoteBusies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Hilgeman, Nix, Bartky & Clark [Page 22]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
DESCRIPTION
"This object reflects the total number of
times that the adjacent (i.e., remote) SDLC
link stations on this port have entered a busy
state (RNR). This object is initialized to
zero when the port is created."
::= { sdlcPortStatsEntry 9 }
sdlcPortStatsIFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
I-Frames that have been received by SDLC link
stations on this port. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 10 }
sdlcPortStatsIFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
I-Frames that have been transmitted by SDLC
link stations on this port. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 11 }
sdlcPortStatsOctetsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total octets
received from adjacent SDLC link stations on
this port. This object covers the address,
control, and information field of I-Frames
only. This object is initialized to zero when
the port is created."
::= { sdlcPortStatsEntry 12 }
sdlcPortStatsOctetsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 23]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"This object reflects the total octets
transmitted to adjacent SDLC link stations on
this port. This object covers the address,
control, and information field of I-Frames
only. This object is initialized to zero when
the port is created."
::= { sdlcPortStatsEntry 13 }
sdlcPortStatsProtocolErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
times that the SDLC link stations on this port
have deactivated the link as a result of
having received a protocol violation from the
adjacent link station. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 14 }
sdlcPortStatsActivityTOs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
times that the SDLC link stations on this port
have deactivated the link as a result of no
activity on the link. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 15 }
sdlcPortStatsRNRLIMITs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
times that the SDLC link stations on this port
have deactivated the link as a result of its
RNRLIMIT timer expiring. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 16 }
sdlcPortStatsRetriesExps OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
Hilgeman, Nix, Bartky & Clark [Page 24]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
STATUS current
DESCRIPTION
"This object reflects the total number of
times that the SDLC link stations on this port
have deactivated the link as a result of a
retry sequence being exhausted. This object
is initialized to zero when the port is
created."
::= { sdlcPortStatsEntry 17 }
sdlcPortStatsRetransmitsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
I-Frames retransmitted by remote link stations
for all SDLC link stations on this port. This
object is initialized to zero when the port is
created."
::= { sdlcPortStatsEntry 18 }
sdlcPortStatsRetransmitsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
I-Frames retransmitted by all local SDLC link
stations on this port. This object is
initialized to zero when the port is created."
::= { sdlcPortStatsEntry 19 }
Hilgeman, Nix, Bartky & Clark [Page 25]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
--
-- THE SDLC LINK STATION GROUP
-- ===========================
--
-- The following classes of information is modelled for each SDLC link
-- station:
--
-- 1. ADMINISTRATIVE ( read-write)
-- 2. OPERATIONAL ( read-only)
-- 3. STATISTICS ( read-only)
-- *************************************************************
-- * *
-- * THE SDLC LINK STATION ADMINISTRATIVE TABLE *
-- * *
-- *************************************************************
sdlcLSAdminTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcLSAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects that can be
changed to manage an SDLC link station.
Changing one of these parameters may take
effect in the operating link immediately or may
wait until the link is restarted depending on
the details of the implementation.
The entries in sdlcLSAdminTable can be created
either by an agent or a management station. The
management station can create an entry in
sdlcLSAdminTable by setting the appropriate
value in sdlcLSAdminRowStatus.
Most of the objects in this read-create table
have corresponding read-only objects in the
sdlcLSOperTable that reflect the current
operating value.
The operating values may be different from
these configured values if changed by XID
negotiation or if a configured parameter was
changed after the link was started."
::= { sdlcLSGroup 1 }
sdlcLSAdminEntry OBJECT-TYPE
Hilgeman, Nix, Bartky & Clark [Page 26]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
SYNTAX SdlcLSAdminEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of configured values for an SDLC link
station."
INDEX { ifIndex, sdlcLSAddress }
::= { sdlcLSAdminTable 1 }
SdlcLSAdminEntry ::= SEQUENCE
{
sdlcLSAddress INTEGER,
sdlcLSAdminName DisplayString,
sdlcLSAdminState INTEGER,
sdlcLSAdminISTATUS INTEGER,
sdlcLSAdminMAXDATASend Integer32,
sdlcLSAdminMAXDATARcv Integer32,
sdlcLSAdminREPLYTO TimeInterval,
sdlcLSAdminMAXIN INTEGER,
sdlcLSAdminMAXOUT INTEGER,
sdlcLSAdminMODULO INTEGER,
sdlcLSAdminRETRIESm INTEGER,
sdlcLSAdminRETRIESt TimeInterval,
sdlcLSAdminRETRIESn Integer32,
sdlcLSAdminRNRLIMIT TimeInterval,
sdlcLSAdminDATMODE INTEGER,
sdlcLSAdminGPoll INTEGER,
sdlcLSAdminSimRim INTEGER,
sdlcLSAdminXmitRcvCap INTEGER,
sdlcLSAdminRowStatus RowStatus
}
sdlcLSAddress OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value is the poll address of the
secondary link station for this SDLC link. It
uniquely identifies the SDLC link station
within a single SDLC port."
::= { sdlcLSAdminEntry 1 }
sdlcLSAdminName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 27]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"An octet string that defines the local name of
the SDLC link station. This field may be sent
in the XID3 control vector 0x0E, type 0xF7."
::= { sdlcLSAdminEntry 2 }
sdlcLSAdminState OBJECT-TYPE
SYNTAX INTEGER
{
inactive(1),
active(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the desired state of the
SDLC station. The managed system shall attempt
to keep the operational state, sdlcLSOperState,
consistent with this value."
DEFVAL { active }
::= { sdlcLSAdminEntry 3 }
sdlcLSAdminISTATUS OBJECT-TYPE
SYNTAX INTEGER
{
inactive(1),
active(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter controls the desired state,
sdlcLSAdminState, of the SDLC link station at
link station start-up."
DEFVAL { active }
::= { sdlcLSAdminEntry 4 }
sdlcLSAdminMAXDATASend OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the maximum PDU size that
the local link station thinks it can send to
the adjacent link station before having
received any XID from the ALS. After the
maximum PDU size that the ALS can receive is
known (via XID exchange) that value is
reflected in sdlcLSOperMAXDATASend and takes
Hilgeman, Nix, Bartky & Clark [Page 28]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
precedence over this object.
This value includes the Transmission Header
(TH) and the Request Header (RH)."
::= { sdlcLSAdminEntry 5 }
sdlcLSAdminMAXDATARcv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object contains the maximum PDU size that
the local link station can receive from the
adjacent link station. This value is sent in
the XID to the ALS.
This value includes the Transmission Header
(TH) and the Request Header (RH)."
::= { sdlcLSAdminEntry 6 }
sdlcLSAdminREPLYTO OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the reply timeout (in
1/100ths of a second) for an SDLC link
station. If the link station does not receive
a response to a poll or message before the
specified time expires then the appropriate
error recovery shall be initiated.
The object descriptor contains the name of an
NCP configuration parameter, REPLYTO. Please
note that the value of this object represents
1/100ths of a second while the NCP REPLYTO is
represented in 1/10ths of a second.
Depending on the implementation, a write
operation to this administered value may not
change the operational value, sdlcLSOperREPLYTO,
until the link station is cycled inactive.
This object only has meaning for SDLC ports
where sdlcPortAdminRole == primary "
DEFVAL { 100 }
::= { sdlcLSAdminEntry 7 }
Hilgeman, Nix, Bartky & Clark [Page 29]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSAdminMAXIN OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the maximum number of
unacknowledged I-frames which an SDLC link
station may receive. This should range from 1
to (sdlcLSAdminMODULO - 1). This value is sent
in the XID to the ALS.
A write operation to this administered value
will not change the operational value,
sdlcLSOperMAXIN, until the link station is
cycled inactive."
DEFVAL { 7 }
::= { sdlcLSAdminEntry 8 }
sdlcLSAdminMAXOUT OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the maximum number of
consecutive unacknowledged I-frames which an
SDLC link station shall send without an
acknowledgement. This shall range from 1 to
(sdlcLSAdminMODULO - 1).
For link stations on switched SDLC lines,
certain implementions may choose to override
this administered value with the value
received in the XID exchange.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperMAXOUT, until the link station is
cycled inactive.
An implementation can support only modulo 8,
only modulo 128, or both."
DEFVAL { 1 }
::= { sdlcLSAdminEntry 9 }
sdlcLSAdminMODULO OBJECT-TYPE
SYNTAX INTEGER
{
Hilgeman, Nix, Bartky & Clark [Page 30]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
eight(8),
onetwentyeight(128)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the modulus for an SDLC
link station. This modulus determines the size
of the rotating acknowledgement window used the
SDLC link station pair.
A write operation to this administered value
will not change the operational value,
sdlcLSOperMODULO, until the link station is
cycled inactive.
An implementation can support only modulo 8,
only modulo 128, or both."
DEFVAL { eight }
::= { sdlcLSAdminEntry 10 }
sdlcLSAdminRETRIESm OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls number of retries in a
retry sequence for the local SDLC link
station. A retry sequence is a series of
retransmitted frames ( data or control) for
which no positive acknowledgement is received.
The number of times that the retry sequence is
to be repeated is controlled by the object:
sdlcLSAdminRETRIESn. The interval between retry
sequences is controlled by the object:
sdlcLSAdminRETRIESt.
A value of zero indicates no retries. If the
value of sdlcLSAdminRETRIESm is zero, then the
values of sdlcLSAdminRETRIESt and
sdlcLSAdminRETRIESn should also be zero.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperRETRIESm, until the link station is
cycled inactive."
Hilgeman, Nix, Bartky & Clark [Page 31]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
DEFVAL { 15 }
::= { sdlcLSAdminEntry 11 }
sdlcLSAdminRETRIESt OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the interval (in 1/100ths
of a second) between retry sequences for the
local SDLC link station if multiple retry
sequences are specified . A retry sequence is
a series of retransmitted frames ( data or
control) for which no positive acknowledgement
is received.
The number of repeated retries sequences is
controlled by the object: sdlcLSAdminRETRIESn.
The retries per sequence is controlled by the
object: sdlcLSAdminRETRIESm.
The object descriptor contains the name of an
NCP configuration parameter, RETRIESt. Please
note that the value of this object represents
1/100ths of a second while the NCP RETRIESt is
represented in seconds.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperRETRIESt, until the link station is
cycled inactive."
DEFVAL { 0 }
::= { sdlcLSAdminEntry 12 }
sdlcLSAdminRETRIESn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the number of times that
a retry sequence is repeated for the local SDLC
link station. A retry sequence is a series of
retransmitted frames ( data or control) for
which no positive acknowledgement is received.
The interval between retry sequences is
controlled by the object: sdlcLSAdminRETRIESn.
Hilgeman, Nix, Bartky & Clark [Page 32]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
The retries per sequence is controlled by the
object: sdlcLSAdminRETRIESm.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperRETRIESn, until the link station is
cycled inactive."
DEFVAL { 0 }
::= { sdlcLSAdminEntry 13 }
sdlcLSAdminRNRLIMIT OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the length of time (in
1/100ths of a second) that an SDLC link station
will allow its adjacent link station to remain
in a busy (RNR) state before declaring it
inoperative.
A value of sdlcLSAdminRNRLIMIT == 0 means there
is no limit.
The object descriptor contains the name of an
NCP configuration parameter, RNRLIMIT. Please
note that the value of this object represents
1/100ths of a second while the NCP RNRLIMIT is
represented in minutes.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperRNRLIMIT, until the link station is
cycled inactive."
DEFVAL { 18000 }
::= { sdlcLSAdminEntry 14 }
sdlcLSAdminDATMODE OBJECT-TYPE
SYNTAX INTEGER
{
half(1),
full(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 33]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"This object controls whether communications
mode with the adjacent link station is
two-way-alternate (half) or two-way-simultaneous
(full).
A write operation to this administered value
will not change the operational value,
sdlcLSOperDATMODE, until the link station is
cycled inactive."
DEFVAL { half }
::= { sdlcLSAdminEntry 15 }
sdlcLSAdminGPoll OBJECT-TYPE
SYNTAX INTEGER (0..254)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object describes the group poll address
for this link station instance. If group poll
is not in effect for this link station
instance, the value for sdlcLSAdminGPoll should
be zero.
Depending on the implementation, a write
operation to this administered value may not
change the operational value, sdlcLSOperGPoll,
until the link station is cycled inactive."
::= { sdlcLSAdminEntry 16 }
sdlcLSAdminSimRim OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
yes(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the support for
transmission and receipt of SIM and RIM control
frames for this link station. The value of
this object controls the setting of the
transmit-receive capability sent in the XID
field."
DEFVAL { no }
::= { sdlcLSAdminEntry 17 }
sdlcLSAdminXmitRcvCap OBJECT-TYPE
Hilgeman, Nix, Bartky & Clark [Page 34]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
SYNTAX INTEGER
{
twa(1),
tws(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the transmit-receive
capabilities for this SDLC link station. The
value of this object establishes the value of
the transmit-receive capability indicator sent
in the XID image to the adjacent link station."
DEFVAL { twa }
::= { sdlcLSAdminEntry 18 }
sdlcLSAdminRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used by a management station to
create or delete the row entry in
sdlcLSAdminTable following the RowStatus
textual convention.
Upon successful creation of the row, an agent
automatically creates a corresponding entry in
the sdlcLSOperTable with sdlcLSOperState equal
to 'discontacted (1)'."
::= { sdlcLSAdminEntry 19 }
-- *************************************************************
-- * *
-- * THE SDLC LINK STATION OPERATIONAL TABLE *
-- * *
-- *************************************************************
sdlcLSOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcLSOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains current SDLC link
parameters. Many of these objects have
corresponding objects in the
sdlcLSAdminTable."
::= { sdlcLSGroup 2 }
Hilgeman, Nix, Bartky & Clark [Page 35]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSOperEntry OBJECT-TYPE
SYNTAX SdlcLSOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of status and control values for an
SDLC link station."
INDEX { ifIndex, sdlcLSAddress }
::= { sdlcLSOperTable 1 }
SdlcLSOperEntry ::= SEQUENCE
{
sdlcLSOperName DisplayString,
sdlcLSOperRole INTEGER,
sdlcLSOperState INTEGER,
sdlcLSOperMAXDATASend Integer32,
sdlcLSOperREPLYTO TimeInterval,
sdlcLSOperMAXIN INTEGER,
sdlcLSOperMAXOUT INTEGER,
sdlcLSOperMODULO INTEGER,
sdlcLSOperRETRIESm INTEGER,
sdlcLSOperRETRIESt TimeInterval,
sdlcLSOperRETRIESn INTEGER,
sdlcLSOperRNRLIMIT TimeInterval,
sdlcLSOperDATMODE INTEGER,
sdlcLSOperLastModifyTime TimeTicks,
sdlcLSOperLastFailTime TimeTicks,
sdlcLSOperLastFailCause INTEGER,
sdlcLSOperLastFailCtrlIn OCTET STRING,
sdlcLSOperLastFailCtrlOut OCTET STRING,
sdlcLSOperLastFailFRMRInfo OCTET STRING,
sdlcLSOperLastFailREPLYTOs Counter32,
sdlcLSOperEcho INTEGER,
sdlcLSOperGPoll INTEGER,
sdlcLSOperSimRim INTEGER,
sdlcLSOperXmitRcvCap INTEGER
}
sdlcLSOperName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An octet string that defines the name of the
remote SDLC link station. This field is
received in the XID3 control vector 0x0E, type
0xF7."
::= { sdlcLSOperEntry 1 }
Hilgeman, Nix, Bartky & Clark [Page 36]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSOperRole OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
secondary(2),
undefined(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current role that the
link station is assuming.
The value of sdlcLSOperRole is undefined(3)
whenever the link station role has not yet been
established by the mode setting command."
::= { sdlcLSOperEntry 2 }
sdlcLSOperState OBJECT-TYPE
SYNTAX INTEGER
{
discontacted(1),
contactPending(2),
contacted(3),
discontactPending(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the operational state of
the SDLC link station. The managed system
shall attempt to keep this value consistent
with the administered state, sdlcLSAdminState"
::= { sdlcLSOperEntry 3 }
sdlcLSOperMAXDATASend OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the actual maximum PDU
size that the local link station can send to
the adjacent link station. This object is
established from the value received in the XID
from the adjacent link station. If no XID
is received, then this value is implementation
dependent (for instance, it could be the value
of sdlcLSAdminMAXDATASend).
Hilgeman, Nix, Bartky & Clark [Page 37]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
This value includes the Transmission Header
(TH) and the Request Header (RH)."
::= { sdlcLSOperEntry 4 }
sdlcLSOperREPLYTO OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current reply timeout
(in 1/100ths of a second) for an SDLC link
station. If the link station does not receive
a response to a poll or message before the
specified time expires then the appropriate
error recovery shall be initiated.
The object descriptor contains the name of an
NCP configuration parameter, REPLYTO. Please
note that the value of this object represents
1/100ths of a second while the NCP REPLYTO is
represented in 1/10ths of a second.
This object only has meaning for SDLC ports
where sdlcPortOperRole == primary "
::= { sdlcLSOperEntry 5 }
sdlcLSOperMAXIN OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current maximum
number of unacknowledged I-frames which an SDLC
link station may receive. This shall range
from 1 to (sdlcLSOperMODULO - 1)."
::= { sdlcLSOperEntry 6 }
sdlcLSOperMAXOUT OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object controls the maximum number of
consecutive unacknowledged I-frames which an
SDLC link station shall send without an
acknowledgement. This shall range from 1 to
(sdlcLSAdminMODULO - 1).
Hilgeman, Nix, Bartky & Clark [Page 38]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
This value may controlled by the administered
MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value
received during the XID exchange."
::= { sdlcLSOperEntry 7 }
sdlcLSOperMODULO OBJECT-TYPE
SYNTAX INTEGER
{
eight(8),
onetwentyeight(128)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current modulus for
an SDLC link station. This modulus determines
the size of rotating acknowledgement window
used by the SDLC link station pair."
DEFVAL { eight }
::= { sdlcLSOperEntry 8 }
sdlcLSOperRETRIESm OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object controls number of retries in a
retry sequence for an SDLC link station. A
retry sequence is a series of retransmitted
frames ( data or control) for which no positive
acknowledgement is received.
The current number of times that the retry
sequence is to be repeated is reflected by the
object: sdlcLSOperRETRIESn. The current
interval between retry sequences is reflected
by the object: sdlcLSOperRETRIESt."
::= { sdlcLSOperEntry 9 }
sdlcLSOperRETRIESt OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current interval (in
1/100ths of a second) between retry sequences
for an SDLC link station if multiple retry
sequences are specified. A retry sequence is a
Hilgeman, Nix, Bartky & Clark [Page 39]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
series of retransmitted frames ( data or
control) for which no positive acknowledgement
is received.
The object descriptor contains the name of an
NCP configuration parameter, RETRIESt. Please
note that the value of this object represents
1/100ths of a second while the NCP RETRIESt is
represented in seconds.
The current number of repeated retries
sequences is reflected by the object:
sdlcLSOperRETRIESn. The current retries per
sequence is reflected by the object:
sdlcLSOperRETRIESm."
::= { sdlcLSOperEntry 10 }
sdlcLSOperRETRIESn OBJECT-TYPE
SYNTAX INTEGER (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current number of
times that a retry sequence is repeated for an
SDLC link station. A retry sequence is a
series of retransmitted frames ( data or
control) for which no positive acknowledgement
is received.
The current interval between retry sequences is
reflected by the object: sdlcLSOperRETRIESn.
The current retries per sequence is reflected
by the object: sdlcLSOperRETRIESm."
::= { sdlcLSOperEntry 11 }
sdlcLSOperRNRLIMIT OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the current length of
time (in 1/100ths of a second) that an SDLC
link station will allow its adjacent link
station to remain in a busy (RNR) state before
declaring it inoperative.
The object descriptor contains the name of an
NCP configuration parameter, RNRLIMIT. Please
Hilgeman, Nix, Bartky & Clark [Page 40]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
note that the value of this object represents
1/100ths of a second while the NCP RNRLIMIT is
represented in minutes.
A value of sdlcLSOperRNRLIMIT == 0 means there
is no limit."
::= { sdlcLSOperEntry 12 }
sdlcLSOperDATMODE OBJECT-TYPE
SYNTAX INTEGER
{
half(1),
full(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects whether the current
communications mode with the adjacent link
station is two-way-alternate (half) or
two-way-simultaneous (full)."
::= { sdlcLSOperEntry 13 }
sdlcLSOperLastModifyTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the value of sysUpTime
when this link station definition was last
modified. If the link station has not been
modified, then this value shall be zero."
::= { sdlcLSOperEntry 14 }
sdlcLSOperLastFailTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the value of sysUpTime
when this SDLC link station last failed. If
the link station has not failed, then this
value shall be zero."
::= { sdlcLSOperEntry 15 }
sdlcLSOperLastFailCause OBJECT-TYPE
SYNTAX INTEGER
{
Hilgeman, Nix, Bartky & Clark [Page 41]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
undefined(1),
rxFRMR(2),
txFRMR(3),
noResponse(4),
protocolErr(5),
noActivity(6),
rnrLimit(7),
retriesExpired(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This enumerated object reflects the cause of
the last failure of this SDLC link station. If
the link station has not failed, then this
object will have a value of undefined(1)."
DEFVAL { undefined }
::= { sdlcLSOperEntry 16 }
sdlcLSOperLastFailCtrlIn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the last control octet or
octets (depending on modulus) received by this
SDLC link station at the time of the last
failure. If the link station has not failed,
then this value has no meaning."
::= { sdlcLSOperEntry 17 }
sdlcLSOperLastFailCtrlOut OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the last control octet or
octets (depending on modulus) sent by this SDLC
link station at the time of the last failure.
If the link station has not failed, then this
value has no meaning."
::= { sdlcLSOperEntry 18 }
sdlcLSOperLastFailFRMRInfo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 42]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"This object reflects the information field of
the FRMR frame if the last failure for this
SDLC link station was as a result of an invalid
frame. Otherwise, this field has no meaning."
::= { sdlcLSOperEntry 19 }
sdlcLSOperLastFailREPLYTOs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the number of times that
the REPLYTO timer had expired for an SDLC link
station at the time of the last failure. If the
link station has not failed, then this value
has no meaning."
::= { sdlcLSOperEntry 20 }
sdlcLSOperEcho OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
yes(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies whether the echo bit is
in effect for this particular link station."
DEFVAL { no }
::= { sdlcLSOperEntry 21 }
sdlcLSOperGPoll OBJECT-TYPE
SYNTAX INTEGER (0..254)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the group poll address
in effect for this link station instance."
DEFVAL { 0 }
::= { sdlcLSOperEntry 22 }
sdlcLSOperSimRim OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
yes(2)
}
Hilgeman, Nix, Bartky & Clark [Page 43]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the support for
transmission and receipt of SIM and RIM control
frames for the adjacent link station. The
value of this object is set from the XID field
received from the adjacent link station."
DEFVAL { no }
::= { sdlcLSOperEntry 23 }
sdlcLSOperXmitRcvCap OBJECT-TYPE
SYNTAX INTEGER
{
twa(1),
tws(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the transmit-receive
capabilities for the adjacent SDLC link
station. The value of this object is the value
of the transmit-receive capability indicator
received in the XID image from the adjacent
link station."
DEFVAL { twa }
::= { sdlcLSOperEntry 24 }
-- *************************************************************
-- * *
-- * THE SDLC LINK STATION STATISTICS TABLE *
-- * *
-- *************************************************************
sdlcLSStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcLSStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table contains statistics
for a specific SDLC link station."
::= { sdlcLSGroup 3 }
sdlcLSStatsEntry OBJECT-TYPE
SYNTAX SdlcLSStatsEntry
MAX-ACCESS not-accessible
Hilgeman, Nix, Bartky & Clark [Page 44]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
STATUS current
DESCRIPTION
"A list of statistics for an SDLC link station."
INDEX { ifIndex, sdlcLSAddress }
::= { sdlcLSStatsTable 1 }
SdlcLSStatsEntry ::= SEQUENCE
{
sdlcLSStatsBLUsIn Counter32,
sdlcLSStatsBLUsOut Counter32,
sdlcLSStatsOctetsIn Counter32,
sdlcLSStatsOctetsOut Counter32,
sdlcLSStatsPollsIn Counter32,
sdlcLSStatsPollsOut Counter32,
sdlcLSStatsPollRspsIn Counter32,
sdlcLSStatsPollRspsOut Counter32,
sdlcLSStatsLocalBusies Counter32,
sdlcLSStatsRemoteBusies Counter32,
sdlcLSStatsIFramesIn Counter32,
sdlcLSStatsIFramesOut Counter32,
sdlcLSStatsUIFramesIn Counter32,
sdlcLSStatsUIFramesOut Counter32,
sdlcLSStatsXIDsIn Counter32,
sdlcLSStatsXIDsOut Counter32,
sdlcLSStatsTESTsIn Counter32,
sdlcLSStatsTESTsOut Counter32,
sdlcLSStatsREJsIn Counter32,
sdlcLSStatsREJsOut Counter32,
sdlcLSStatsFRMRsIn Counter32,
sdlcLSStatsFRMRsOut Counter32,
sdlcLSStatsSIMsIn Counter32,
sdlcLSStatsSIMsOut Counter32,
sdlcLSStatsRIMsIn Counter32,
sdlcLSStatsRIMsOut Counter32,
sdlcLSStatsDISCIn Counter32,
sdlcLSStatsDISCOut Counter32,
sdlcLSStatsUAIn Counter32,
sdlcLSStatsUAOut Counter32,
sdlcLSStatsDMIn Counter32,
sdlcLSStatsDMOut Counter32,
sdlcLSStatsSNRMIn Counter32,
sdlcLSStatsSNRMOut Counter32,
sdlcLSStatsProtocolErrs Counter32,
sdlcLSStatsActivityTOs Counter32,
sdlcLSStatsRNRLIMITs Counter32,
sdlcLSStatsRetriesExps Counter32,
sdlcLSStatsRetransmitsIn Counter32,
sdlcLSStatsRetransmitsOut Counter32
Hilgeman, Nix, Bartky & Clark [Page 45]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
}
sdlcLSStatsBLUsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total basic link
units (BLUs; frames) received from an adjacent
SDLC link station since link station startup.
At link station startup time, this object must
be initialized to zero."
::= { sdlcLSStatsEntry 1 }
sdlcLSStatsBLUsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total basic link
units (BLUs; frames), transmitted to an
adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 2 }
sdlcLSStatsOctetsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total octets received
from an adjacent SDLC link station since link
station startup. This object covers the
address, control, and information field of
I-Frames only. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 3 }
sdlcLSStatsOctetsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total octets
transmitted to an adjacent SDLC link station
since link station startup. This object covers
the address, control, and information field of
Hilgeman, Nix, Bartky & Clark [Page 46]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
I-Frames only. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 4 }
sdlcLSStatsPollsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total polls received
from an adjacent SDLC link station since link
station startup. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 5 }
sdlcLSStatsPollsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total polls sent to
an adjacent SDLC link station since link
station startup. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 6 }
sdlcLSStatsPollRspsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of poll
responses sent to the adjacent SDLC link
station since link station startup. This value
includes I-frames that are sent in response to
a poll.
At link station startup time, this object must
be initialized to zero."
::= { sdlcLSStatsEntry 7 }
sdlcLSStatsPollRspsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of poll
responses received from the adjacent SDLC link
Hilgeman, Nix, Bartky & Clark [Page 47]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
station since station startup. This value
includes I-frames that are received in response
to a poll.
At link station startup time, this object must
be initialized to zero."
::= { sdlcLSStatsEntry 8 }
sdlcLSStatsLocalBusies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of times
that the local SDLC link station has entered a
busy state (RNR) since link station startup.
At link station startup time, this object must
be initialized to zero."
::= { sdlcLSStatsEntry 9 }
sdlcLSStatsRemoteBusies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of times
that an adjacent ( remote) SDLC link station
has entered a busy state (RNR) since link
station startup. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 10 }
sdlcLSStatsIFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total I-frames
received from an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 11 }
sdlcLSStatsIFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Hilgeman, Nix, Bartky & Clark [Page 48]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
DESCRIPTION
"This object reflects the total I-frames
transmitted to an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 12 }
sdlcLSStatsUIFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total UI-frames
received from an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 13 }
sdlcLSStatsUIFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total UI-frames
transmitted to an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 14 }
sdlcLSStatsXIDsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total XID frames
received from an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 15 }
sdlcLSStatsXIDsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total XID frames
transmitted to an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 16 }
Hilgeman, Nix, Bartky & Clark [Page 49]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSStatsTESTsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total TEST frames,
commands or responses, received from an
adjacent SDLC link station since link station
startup."
::= { sdlcLSStatsEntry 17 }
sdlcLSStatsTESTsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total TEST frames,
commands or responses, transmitted to an
adjacent SDLC link station since link station
startup."
::= { sdlcLSStatsEntry 18 }
sdlcLSStatsREJsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total REJ frames
received from an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 19 }
sdlcLSStatsREJsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total REJ frames
transmitted to an adjacent SDLC link station
since link station startup."
::= { sdlcLSStatsEntry 20 }
sdlcLSStatsFRMRsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total frame reject
Hilgeman, Nix, Bartky & Clark [Page 50]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
(FRMR) frames received from an adjacent SDLC
link station since link station startup."
::= { sdlcLSStatsEntry 21 }
sdlcLSStatsFRMRsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total frame reject
(FRMR) frames transmitted to an adjacent SDLC
link station since link station startup."
::= { sdlcLSStatsEntry 22 }
sdlcLSStatsSIMsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total set
initialization mode (SIM) frames received from
an adjacent SDLC link station since link station
startup."
::= { sdlcLSStatsEntry 23 }
sdlcLSStatsSIMsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total set
initialization mode (SIM) frames transmitted to
an adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 24 }
sdlcLSStatsRIMsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total request
initialization mode (RIM) frames received from
an adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 25 }
Hilgeman, Nix, Bartky & Clark [Page 51]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSStatsRIMsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total request
initialization mode (RIM) frames transmitted to
an adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 26 }
sdlcLSStatsDISCIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
disconnect (DISC) requests received from an
adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 27 }
sdlcLSStatsDISCOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
disconnect (DISC) requests transmited to an
adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 28 }
sdlcLSStatsUAIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
unnumbered acknowledgements (UA) requests
received from an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 29 }
Hilgeman, Nix, Bartky & Clark [Page 52]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSStatsUAOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
unnumbered acknowledgements (UA) requests
transmited to an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 30 }
sdlcLSStatsDMIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
disconnect mode (DM) requests received from an
adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 31 }
sdlcLSStatsDMOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
disconnect mode (DM) requests transmited to an
adjacent SDLC link station since link station
startup. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 32 }
sdlcLSStatsSNRMIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
set normal response mode (SNRM/SNRME) requests
received from an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
Hilgeman, Nix, Bartky & Clark [Page 53]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
::= { sdlcLSStatsEntry 33 }
sdlcLSStatsSNRMOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
set normal response mode (SNRM/SNRME) requests
transmited to an adjacent SDLC link station
since link station startup. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 34 }
sdlcLSStatsProtocolErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total occurrences,
since link station startup, where this SDLC
link station has inactivated the link as a
result of receiving a frame from its adjacent
link station which was in violation of the
protocol. At link station startup time, this
object must be initialized to zero."
::= { sdlcLSStatsEntry 35 }
sdlcLSStatsActivityTOs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total occurrences,
since startup, where this SDLC link station has
inactivated the link as a result of no activity
on the link. At link station startup time,
this object must be initialized to zero."
::= { sdlcLSStatsEntry 36 }
sdlcLSStatsRNRLIMITs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total occurrences,
since startup, where this SDLC link station has
Hilgeman, Nix, Bartky & Clark [Page 54]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
inactivated the link as a result of its
RNRLIMIT timer expiring. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 37 }
sdlcLSStatsRetriesExps OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total occurrences,
since startup, where this SDLC link station has
inactivated the link as a result of a retry
sequence being exhausted. At link station
startup time, this object must be initialized
to zero."
::= { sdlcLSStatsEntry 38 }
sdlcLSStatsRetransmitsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the total number of
information frames retransmitted by the remote
link station because the N(s) received from
that link station indicated that one or more
information frames sent by that station were
lost. This event causes the first missing
information frame of a window and all
subsequent information frames to be
retransmitted. At link station startup time,
this object must be initialized to zero.
Management: If the value of
sdlcLSStatsRetransmitsIn grows over time, then
the quality of the serial line is in
question. You might want to look at
decreasing the value for
sdlcLSAdminMAXDATASend to compensate for the
lower quality line."
::= { sdlcLSStatsEntry 39 }
sdlcLSStatsRetransmitsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Hilgeman, Nix, Bartky & Clark [Page 55]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
DESCRIPTION
"This object reflects the total number of
information frames retransmitted to a remote
link station because the N(r) received from
that link station indicated that one or more
information frames sent to that station were
lost. This event causes the first missing
information frame of a window and all
subsequent information frames to be
retransmitted. At link station startup time,
this object must be initialized to zero.
Management: If the value of
sdlcLSStatsRetransmitsOut grows over time,
then the quality of the serial line is in
question. You might want to look at
decreasing the value for sdlcLSAdminMAXDATASend
to compensate for the lower quality line."
::= { sdlcLSStatsEntry 40 }
--
-- TRAP DEFINITIONS
--
--
-- Notifications
--
sdlcTraps OBJECT IDENTIFIER ::= { sdlc 3 }
sdlcPortStatusChange NOTIFICATION-TYPE
OBJECTS { ifIndex,
ifAdminStatus,
ifOperStatus,
sdlcPortOperLastFailTime,
sdlcPortOperLastFailCause
}
STATUS current
DESCRIPTION
"This trap indicates that the state of an SDLC
port has transitioned to active or inactive."
::= { sdlcTraps 1 }
sdlcLSStatusChange NOTIFICATION-TYPE
OBJECTS { ifIndex,
sdlcLSAddress,
sdlcLSOperState,
sdlcLSAdminState,
Hilgeman, Nix, Bartky & Clark [Page 56]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSOperLastFailTime,
sdlcLSOperLastFailCause,
sdlcLSOperLastFailFRMRInfo,
sdlcLSOperLastFailCtrlIn,
sdlcLSOperLastFailCtrlOut,
sdlcLSOperLastFailREPLYTOs
}
STATUS current
DESCRIPTION
"This trap indicates that the state of an SDLC
link station has transitioned to contacted or
discontacted."
::= { sdlcTraps 2 }
--
-- Conformance Information
--
sdlcConformance OBJECT IDENTIFIER ::= { sdlc 4 }
sdlcCompliances OBJECT IDENTIFIER ::= { sdlcConformance 1 }
sdlcGroups OBJECT IDENTIFIER ::= { sdlcConformance 2 }
--
-- Compliance Statements
--
sdlcCoreCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The core compliance statement for all SDLC
nodes."
MODULE
MANDATORY-GROUPS
{
sdlcCorePortAdminGroup,
sdlcCorePortOperGroup,
sdlcCorePortStatsGroup,
sdlcCoreLSAdminGroup,
sdlcCoreLSOperGroup,
sdlcCoreLSStatsGroup
}
OBJECT sdlcPortAdminName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
Hilgeman, Nix, Bartky & Clark [Page 57]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
OBJECT sdlcPortAdminRole
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcPortAdminType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcPortAdminTopology
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcPortAdminISTATUS
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAddress
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminState
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminISTATUS
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminMAXDATASend
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminMAXDATARcv
MIN-ACCESS read-only
DESCRIPTION
Hilgeman, Nix, Bartky & Clark [Page 58]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
"Write access is not required."
OBJECT sdlcLSAdminMAXIN
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminMAXOUT
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminMODULO
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminRETRIESm
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminRETRIESt
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminRETRIESn
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminRNRLIMIT
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminDATMODE
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminGPoll
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminSimRim
Hilgeman, Nix, Bartky & Clark [Page 59]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { sdlcCompliances 1 }
sdlcPrimaryCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for all nodes that
are performing the role of a Primary link
station."
MODULE
MANDATORY-GROUPS { sdlcPrimaryGroup }
OBJECT sdlcPortAdminPAUSE
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcLSAdminREPLYTO
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { sdlcCompliances 2 }
sdlcPrimaryMultipointCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for all nodes that
are performing the role of a primary link
station on a multipoint line."
MODULE
MANDATORY-GROUPS { sdlcPrimaryMultipointGroup }
OBJECT sdlcPortAdminSERVLIM
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sdlcPortAdminSlowPollTimer
MIN-ACCESS read-only
Hilgeman, Nix, Bartky & Clark [Page 60]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
DESCRIPTION
"Write access is not required."
::= { sdlcCompliances 3 }
--
-- Core Conformance Groups for All Link Stations
--
sdlcCoreGroups OBJECT IDENTIFIER ::= { sdlcGroups 1 }
sdlcCorePortAdminGroup OBJECT-GROUP
OBJECTS
{
sdlcPortAdminName, sdlcPortAdminRole,
sdlcPortAdminType, sdlcPortAdminTopology,
sdlcPortAdminISTATUS
}
STATUS current
DESCRIPTION
"The sdlcCorePortAdminGroup defines objects
which are common to the PortAdmin group of all
compliant link stations."
::= { sdlcCoreGroups 1 }
sdlcCorePortOperGroup OBJECT-GROUP
OBJECTS
{
sdlcPortOperName,
sdlcPortOperRole,
sdlcPortOperType,
sdlcPortOperTopology,
sdlcPortOperISTATUS,
sdlcPortOperACTIVTO,
sdlcPortOperLastFailTime,
sdlcPortOperLastFailCause
}
STATUS current
DESCRIPTION
"The sdlcCorePortOperGroup defines objects
which are common to the PortOper group of all
compliant link stations."
::= { sdlcCoreGroups 2 }
sdlcCorePortStatsGroup OBJECT-GROUP
OBJECTS
Hilgeman, Nix, Bartky & Clark [Page 61]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
{
sdlcPortStatsPhysicalFailures,
sdlcPortStatsInvalidAddresses,
sdlcPortStatsDwarfFrames
}
STATUS current
DESCRIPTION
"The sdlcCorePortStatsGroup defines objects
which are common to the PortStats group of all
compliant link stations."
::= { sdlcCoreGroups 3 }
sdlcCoreLSAdminGroup OBJECT-GROUP
OBJECTS
{
sdlcLSAddress,
sdlcLSAdminName,
sdlcLSAdminState,
sdlcLSAdminISTATUS,
sdlcLSAdminMAXDATASend,
sdlcLSAdminMAXDATARcv,
sdlcLSAdminMAXIN,
sdlcLSAdminMAXOUT,
sdlcLSAdminMODULO,
sdlcLSAdminRETRIESm,
sdlcLSAdminRETRIESt,
sdlcLSAdminRETRIESn,
sdlcLSAdminRNRLIMIT,
sdlcLSAdminDATMODE,
sdlcLSAdminGPoll,
sdlcLSAdminSimRim,
sdlcLSAdminRowStatus
}
STATUS current
DESCRIPTION
"The sdlcCorePortAdminGroup defines objects
which are common to the PortAdmin group of all
compliant link stations."
::= { sdlcCoreGroups 4 }
sdlcCoreLSOperGroup OBJECT-GROUP
OBJECTS
{
sdlcLSOperRole,
sdlcLSOperState,
sdlcLSOperMAXDATASend,
sdlcLSOperMAXIN,
Hilgeman, Nix, Bartky & Clark [Page 62]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSOperMAXOUT,
sdlcLSOperMODULO,
sdlcLSOperRETRIESm,
sdlcLSOperRETRIESt,
sdlcLSOperRETRIESn,
sdlcLSOperRNRLIMIT,
sdlcLSOperDATMODE,
sdlcLSOperLastFailTime,
sdlcLSOperLastFailCause,
sdlcLSOperLastFailCtrlIn,
sdlcLSOperLastFailCtrlOut,
sdlcLSOperLastFailFRMRInfo,
sdlcLSOperLastFailREPLYTOs,
sdlcLSOperEcho,
sdlcLSOperGPoll
}
STATUS current
DESCRIPTION
"The sdlcCorePortOperGroup defines objects
which are common to the PortOper group of all
compliant link stations."
::= { sdlcCoreGroups 5 }
sdlcCoreLSStatsGroup OBJECT-GROUP
OBJECTS
{
sdlcLSStatsBLUsIn,
sdlcLSStatsBLUsOut,
sdlcLSStatsOctetsIn,
sdlcLSStatsOctetsOut,
sdlcLSStatsPollsIn,
sdlcLSStatsPollsOut,
sdlcLSStatsPollRspsIn,
sdlcLSStatsPollRspsOut,
sdlcLSStatsLocalBusies,
sdlcLSStatsRemoteBusies,
sdlcLSStatsIFramesIn,
sdlcLSStatsIFramesOut,
sdlcLSStatsRetransmitsIn,
sdlcLSStatsRetransmitsOut,
sdlcLSStatsUIFramesIn,
sdlcLSStatsUIFramesOut,
sdlcLSStatsXIDsIn,
sdlcLSStatsXIDsOut,
sdlcLSStatsTESTsIn,
sdlcLSStatsTESTsOut,
sdlcLSStatsREJsIn,
Hilgeman, Nix, Bartky & Clark [Page 63]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
sdlcLSStatsREJsOut,
sdlcLSStatsFRMRsIn,
sdlcLSStatsFRMRsOut,
sdlcLSStatsSIMsIn,
sdlcLSStatsSIMsOut,
sdlcLSStatsRIMsIn,
sdlcLSStatsRIMsOut,
sdlcLSStatsProtocolErrs,
sdlcLSStatsRNRLIMITs,
sdlcLSStatsRetriesExps
}
STATUS current
DESCRIPTION
"The sdlcCorePortStatsGroup defines objects
which are common to the PortStats group of all
compliant link stations."
::= { sdlcCoreGroups 6 }
--
-- Conformance Groups for Primary Link Stations
--
sdlcPrimaryGroups OBJECT IDENTIFIER ::= { sdlcGroups 2 }
sdlcPrimaryGroup OBJECT-GROUP
OBJECTS
{
sdlcPortAdminPAUSE,
sdlcPortOperPAUSE,
sdlcLSAdminREPLYTO,
sdlcLSOperREPLYTO
}
STATUS current
DESCRIPTION
"The sdlcPrimaryGroup defines objects which
are common to all compliant primary link
stations."
::= { sdlcPrimaryGroups 1 }
sdlcPrimaryMultipointGroup OBJECT-GROUP
OBJECTS
{
sdlcPortAdminSERVLIM,
sdlcPortAdminSlowPollTimer,
sdlcPortOperSlowPollMethod,
sdlcPortOperSERVLIM,
sdlcPortOperSlowPollTimer
Hilgeman, Nix, Bartky & Clark [Page 64]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
}
STATUS current
DESCRIPTION
"The sdlcPrimaryMultipointGroup defines objects
which are common to all compliant primary link
stations that are in a multipoint topology."
::= { sdlcPrimaryGroups 2 }
END
4. Acknowledgments
Thanks goes to the SNADLC MIB working group for reviewing this MIB
and for their infinite patience through the editing process.
5. References
[1] Stewart, B., "Definitions of Managed Objects for RS-232-like
Hardware Devices using SMIv2", RFC 1659, Xyplex, July 1994.
[2] "Synchronous Data Link Control: Concepts", IBM Publication No.
GA27-3093-04, 5th edition, May 1992.
[3] "Vocabulary for Data Processing Telecommunications, and Office
Systems", IBM Publication No. GC20-1699-6.
[4] Kostick, D., Kielczewski, Z., and K. Shih, Editors, "Definitions
of Managed Objects for SNA NAUs using SMIv2", RFC 1666, Eicon
Technology Corporation, Bell Communications Research, Novell,
August 1994.
[5] Waldbusser, S., "Row Creation with SNMPv1", Work in Progress.
[6] McCloghrie K., and F. Kastenholz, "Evolution of the Interfaces
Group of MIB-II", RFC 1573, Hughes LAN Syst, FTP Software,
January 1994.
Hilgeman, Nix, Bartky & Clark [Page 65]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
6. Glossary
link station
A link station comprises procedures and control information
that coordinate the transfer of data between two nodes joined
by a link connection. All traffic over the link connection is
from the primary link station to one or more secondary link
stations, or from a secondary link station to the primary link
station.
primary link station
The link station instance on a link connection that is
responsible for the control of the data link. There must be
only one primary link station on a link connection. The
primary link station issues commands to one or more secondary
link stations.
secondary link station
The link station instance on a link connection that receives
commands from the primary link station and issues responses to
it.
switched line
A telecommunications line in which the connection is
established by dialing. For switched lines, the SDLC startup
sequence typically begins with a null exchange identifier (null
XID).
leased line
A telecommunications line on which connections do not have to
be established by dialing. For leased lines, the SDLC startup
sequence may or may not begin with an exchange identifer (XID).
While there are interface (e.g., RS.232) differences between
leased and switched lines, those interface differences do not
map one-to-one with differences in the SDLC startup protocol
(i.e., the interface and the SDLC protocol are independent from
one another).
point-to-point link
A link that connects the single primary link station to single
secondary link station. A point-to-point link may be either
switched or leased.
multipoint link
A link that connects the single primary link station to several
secondary link stations. A multipoint link may be either
switched or leased. Note: The physical interface signals for a
multipoint link are different than for a point-to-point link.
Hilgeman, Nix, Bartky & Clark [Page 66]
^L
RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
Synonymous with multidrop line.
7. Security Considerations
Security issues are not discussed in this memo.
8. Authors' Addresses
Jeff Hilgeman (chair)
Apertus Technologies, Inc.
7275 Flying Cloud Dr.
Eden Prarie, MN 55344
Phone: 1 612 828 0668
EMail: jeffh@apertus.com
Shannon D. Nix
Metaplex, Inc.
7412 Wingfoot Dr.
Raleigh, NC 27615
Phone: 1 919 878 0811
EMail: snix@metaplex.com
Alan Bartky
Sync Research, Inc.
7 Studebaker
Irvine, CA 92718
Phone: 1 714 588 2070
EMail: alan@sync.com
Wayne Clark (editor)
cisco Systems, Inc.
3100 Smoketree Ct.
Suite 1000
Raleigh, NC 27604
Phone: 1 919 878 6958
EMail: wclark@cisco.com
Hilgeman, Nix, Bartky & Clark [Page 67]
^L
|