summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc3592.txt
blob: 3af4868405f20f4a30fec4349fc21f7597a4a82f (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
Network Working Group                                          K. Tesink
Request for Comments: 3592                        Telcordia Technologies
Obsoletes: 2558                                           September 2003
Category: Standards Track


                Definitions of Managed Objects for the
            Synchronous Optical Network/Synchronous Digital
                  Hierarchy (SONET/SDH) Interface Type

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2003).  All Rights Reserved.

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in TCP/IP-based internets.
   In particular, it defines objects for managing Synchronous Optical
   Network/Synchronous Digital Hierarchy (SONET/SDH) interfaces.  This
   document is a companion to the documents that define Managed Objects
   for the DS1/E1/DS2/E2 and DS3/E3 Interface Types.

   This memo replaces RFC 2558.  Changes relative to RFC 2558 are
   summarized in the MIB module's REVISION clause.

Table of Contents

   1.  Conventions ..................................................  2
   2.  The Internet-Standard Management Framework ...................  3
   3.  Overview .....................................................  3
       3.1.  Use of the ifTable .....................................  3
       3.2.  Use of ifTable for SONET/SDH
             Medium/Section/Line Layer ..............................  5
       3.3.  Use of ifTable for SONET/SDH Paths .....................  6
       3.4.  Use of ifTable for SONET/SDH VTs/VCs ...................  7
       3.5.  SONET/SDH Terminology ..................................  7
   4.  Object Definitions ........................................... 15
       4.1.  The SONET/SDH Medium Group ............................. 19
       4.2.  The SONET/SDH Section Group ............................ 23



Tesink                      Standards Track                     [Page 1]
^L
RFC 3592                   SONET/SDH Objects              September 2003


             4.2.1.  The SONET/SDH Section Current Group ............ 23
             4.2.2.  The SONET/SDH Section Interval Group ........... 25
       4.3.  The SONET/SDH Line Group ............................... 28
             4.3.1.  The SONET/SDH Line Current Group ............... 28
             4.3.2.  The SONET/SDH Line Interval Group .............. 30
       4.4.  The SONET/SDH Far End Line Group ....................... 32
             4.4.1.  The SONET/SDH Far End Line Current Group ....... 32
             4.4.2.  The SONET/SDH Far End Line Interval Group ...... 34
       4.5.  The SONET/SDH Path Group ............................... 37
             4.5.1.  The SONET/SDH Path Current Group ............... 37
             4.5.2.  The SONET/SDH Path Interval Group .............. 39
       4.6.  The SONET/SDH Far End Path Group ....................... 42
             4.6.1.  The SONET/SDH Far End Path Current Group ....... 42
             4.6.2.  The SONET/SDH Far End Path Interval Group ...... 44
       4.7.  The SONET/SDH Virtual Tributary Group .................. 46
             4.7.1.  The SONET/SDH VT Current Group ................. 46
             4.7.2.  The SONET/SDH VT Interval Group ................ 49
       4.8.  The SONET/SDH Far End VT Group ......................... 51
             4.8.1.  The SONET/SDH Far End VT Current Group ......... 51
             4.8.2.  The SONET/SDH Far End VT Interval Group......... 53
       4.9.  Conformance Information ................................ 56
       4.10. Compliance Statements .................................. 56
   5.  Acknowledgments .............................................. 65
   6.  Security Considerations ...................................... 65
   7.  References ................................................... 66
       7.1.  Normative References ................................... 66
       7.2.  Informative References ................................. 68
   8.  Intellectual Property Statement .............................. 68
   Appendix A: The delay-line approach to statistics collection ..... 69
   Appendix B: RFC 1595 SES interpretation .......................... 71
   Author's Address ................................................. 72
   Full Copyright Statement ......................................... 73

1.  Conventions

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL", when they appear in this document, are to be interpreted
   as described in BCP 14, RFC 2119 [RFC2119].












Tesink                      Standards Track                     [Page 2]
^L
RFC 3592                   SONET/SDH Objects              September 2003


2.  The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
   [RFC2580].

   Textual conventions used in this document are defined in RFC 2579
   [RFC2579] and RFC 3593 [RFC3593].

3.  Overview

   These objects are used when the particular media being used to
   realize an interface is a SONET/SDH interface.  At present, this
   applies to these values of the ifType variable in the Internet-
   standard MIB:

      sonet (39), sonetPath (50), sonetVT (51)

   The definitions contained herein are based on the SONET/SDH
   specifications in ANSI T1.105 and T1.106-1988
   [T1.105a][T1.105b][T1.106] and CCITT G.707, 708, 709, and G.783
   [G.707][G.708][G.709][G.783].

3.1.  Use of the ifTable

   This section specifies how the MIB II interfaces group, as defined in
   [RFC2863], is used for SONET/SDH interfaces.  The SONET/SDH layers
   support several multiplexing possibilities.

   For example in SONET, an Synchronous Transport Signal 3 (STS-3) has 3
   SONET Paths, and a STS-3c has 1 SONET Path.  Another example could be
   a STS-12 having 4 SONET STS-3c Paths.  Similarly, a SONET Synchronous
   Payload Envelope (SPE) can carry many Virtual Tributaries (VTs), for
   example, one SONET SPE can carry 28 VT1.5s.  It is important to note
   that an SPE and a VT in SONET is collectively referred to as a
   Virtual Container (VC) in SDH.  Also, an STS is called Synchronous
   Transport Module (STM) in SDH.





Tesink                      Standards Track                     [Page 3]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   Not all SONET/SDH equipment terminates all SONET/SDH layers. For
   example, a SONET/SDH STE regenerator terminates SONET/SDH Sections
   only, and is transparent for all layers above that. SONET/SDH Add-
   Drop multiplexers and Digital Cross Connect Systems terminate
   SONET/SDH Lines.  SONET/SDH Terminal Multiplexers may also terminate
   SONET/SDH Paths and VTs/VCs.

   MIB II [RFC1213], as extended by [RFC2863], accommodates these cases
   by appropriate use of the MIB II system group, and the interfaces
   group.  The system group can name and describe the type of managed
   resource.  The interfaces group defines which SONET/SDH layers apply,
   how these layers are configured and multiplexed.  This is achieved by
   proper representation of SONET/SDH Layers by ifEntries as defined in
   [RFC2863], as follows:

    _____________________________
   |             |          |    |  >
   |             |          |    |  |
   |    VT 1     |..........|VT K|   > K ifEntries
   |             |          |    |  |
   |_____________|__________|____|  >
   |               |      |      |  >
   |               |      |      |  |
   |    Path 1     |......|Path L|   > L ifEntries
   |               |      |      |  |
   |_______________|______|______|  >
   |                             |  >
   |                             |  |
   |    Line                     |  |
   |                             |  |
   |_____________________________|  |
   |                             |  |
   |                             |  |
   |    Section Layer            |   > 1 ifEntry
   |                             |  |
   |_____________________________|  |
   |                             |  |
   |                             |  |
   |    Physical Medium Layer    |  |
   |                             |  |
   |_____________________________|  >

   Use of ifTable for a SONET/SDH port

   The exact configuration and multiplexing of the layers is maintained
   in the ifStackTable [RFC2863] and in the ifInvStackTable [RFC2864].





Tesink                      Standards Track                     [Page 4]
^L
RFC 3592                   SONET/SDH Objects              September 2003


3.2.  Use of ifTable for SONET/SDH Medium/Section/Line Layer

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for combined SONET/SDH
                     Medium/Section/Line Layer
   =====================================================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH Medium/Section/Line

    ifType            sonet(39)

    ifSpeed           Speed of line rate for SONET/SDH,
                      (e.g., 155520000 bps).

    ifPhysAddress     The value of the Circuit Identifier.
                      If no Circuit Identifier has been assigned
                      this object should have an octet string with
                      zero length.

    ifAdminStatus     May be implemented with read-only access.
                      The desired administrative status of the
                      interface.

    ifOperStatus      The value testing(3) is not used.
                      This object assumes the value down(2),
                      if the objects sonetSectionCurrentStatus
                      and sonetLineCurrentStatus have
                      any other value than sonetSectionNoDefect(1)
                      and sonetLineNoDefect(1), respectively.

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is enabled(1).
                             May be implemented with read-only access.

    ifHighSpeed       Speed of line in Mega-bits per second
                      (e.g., 155 Mbps)

    ifConnectorPresent Set to true(1).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.




Tesink                      Standards Track                     [Page 5]
^L
RFC 3592                   SONET/SDH Objects              September 2003


3.3.  Use of ifTable for SONET/SDH Paths

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for SONET/SDH Paths
   =========================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH Path

    ifType            sonetPath(50)

    ifSpeed           set to speed of SONET/SDH path
                      (e.g., an STS-1 path has a
                      rate of 50112000 bps.)

    ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.

    ifAdminStatus     May be implemented with read-only access.
                      The desired administrative status of the
                      interface.

    ifOperStatus      This object assumes the value down(2),
                      if the object sonetPathCurrentStatus has
                      any other value than sonetPathNoDefect(1).

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is disabled(2).
                             May be implemented with read-only access.

    ifHighSpeed       Set to rate of SONET/SDH path
                      in Mega-bits per second.

    ifConnectorPresent Set to false(2).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.










Tesink                      Standards Track                     [Page 6]
^L
RFC 3592                   SONET/SDH Objects              September 2003


3.4.  Use of ifTable for SONET/SDH VTs/VCs

   Only the ifGeneralInformationGroup needs to be supported.

   ifTable Object    Use for SONET/SDH VTs/VCs
   ===========================================
    ifIndex           Interface index.

    ifDescr           SONET/SDH VT/VC

    ifType            sonetVT(51)

    ifSpeed           Set to speed of VT/VC
                      (e.g., a VT1.5 has a rate of
                      1728000 bps.)

    ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.

    ifAdminStatus     May be implemented with read-only access.
                      The desired administrative status of the
                      interface.

    ifOperStatus      This object assumes the value down(2),
                      if the object sonetVTCurrentStatus has
                      any other value than sonetVTNoDefect(1).

    ifLastChange      sysUpTime at the last change in ifOperStatus.

    ifName            Textual name of the interface or an OCTET STRING
                      of zero length.

    ifLinkUpDownTrapEnable   Default value is disabled(2).
                             May be implemented with read-only access.

    ifHighSpeed       Set to rate of VT in Mega-bits per second.

    ifConnectorPresent Set to false(2).

    ifAlias            The (non-volatile) alias name for this interface
                       as assigned by the network manager.

3.5.  SONET/SDH Terminology

   The terminology used in this document to describe error conditions on
   a SONET circuit as monitored by a SONET system are from the T1.231
   [T1M1.3][T1.231a][T1.231b].  The terminology used in this document to
   describe error conditions on a SDH circuit as monitored by a SDH
   system are from the CCITT G.783 [G.783].  Only the SONET Performance



Tesink                      Standards Track                     [Page 7]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   Monitoring terminology is defined in this document.  The definitions
   for SDH Performance Monitoring terms are similar but not identical,
   and they can be found in [G.783].  If the definition in this document
   does not match the definition in the T1.231 document, the implementer
   should follow the definition described in this document.  In some
   cases other or additional references are used as compared with the
   ones cited above.  This will be indicated in the text.

   Section Loss Of Frame Failure (Out of Frame Event, Severely
      Errored Frame Defect) An Out of Frame (OOF) event (or Severely
      Errored Frame defect) is the occurrence of four contiguous errored
      frame alignment words.  A frame alignment word occupies the A1 and
      A2 bytes of an STS frame, and is defined in T1.105.  The SEF
      defect is terminated when two contiguous error-free frame words
      are detected.  Any implementation of the frame recovery circuitry
      which achieves realignment following an OOF within the 250
      microsecond (two frames) interval implied by this definition is
      acceptable.

      A Loss of Frame (LOF) defect is declared when an OOF/SEF defect
      persists for a period of 3 milliseconds.  The LOF defect is
      terminated when the incoming signal remains continuously in-frame
      for a period of 1 ms to 3 ms.

      A LOF failure is declared when the LOF defect persists for a
      period of 2.5 +/- 0.5 seconds, except when an LOS defect or
      failure is present.  The LOF failure is cleared when the LOS
      failure is declared, or when the LOF defect is absent for 10 +/-
      0.5 seconds.

   Loss of Signal
      The Loss of Signal (LOS) defect is declared when no transitions
      are detected on the incoming signal (before descrambling).  The
      LOS defect is detected  upon observing 2.3 to 100 microseconds of
      no transitions.  The LOS defect is cleared after a 125 microsecond
      interval (one frame) during which no LOS defect is detected.

      The LOS failure is declared when the LOS defect persists for a
      period of 2.5 +/- 0.5 seconds, or if LOS defect is present when
      the criteria for LOF failure declaration have been met.  The LOS
      failure is cleared when the LOS defect is absent for a period of
      10 +/- 0.5 seconds.  Declaration of LOS failure clears any
      existing LOF failure.  Clearing the LOS failure allows immediate
      declaration of the LOF failure if conditions warrant.







Tesink                      Standards Track                     [Page 8]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   STS-Path Loss of Pointer
      A Loss of Pointer (LOP) defect is declared when either a valid
      pointer is not detected in eight consecutive frames, or when eight
      consecutive frames are detected with the New Data Flag (NDF) set
      to "1001" without a valid concatenation indicator (see ANSI
      T1.105).  A LOP defect is terminated when either a valid pointer
      with a normal NDF set to "0110", or a valid concatenation
      indicator is detected for three contiguous frames.  Incoming STS-
      Path AIS shall not result in the declaration of a LOP defect.

      An STS-Path LOP failure is declared when the STS-Path LOP defect
      persists for a period of 2.5 +/- 0.5 seconds.  A STS-Path LOP
      failure is cleared when the STS-Path LOP defect is absent for 10
      +/- 0.5 seconds.

   VT Loss of Pointer
      A VT LOP defect is declared when either a valid pointer is not
      detected in eight consecutive VT superframes, or when eight
      consecutive VT superframes are detected with the NDF set to "1001"
      without a valid concatenation indicator.  A VT LOP defect is
      terminated when either a valid pointer with a normal NDF set to
      "0110", or a valid concatenation indicator is detected for three
      contiguous VT superframes.  Incoming VT-Path AIS shall not result
      in declaring a VT LOP defect.

      A VT LOP failure is declared when the VT LOP defect persists for
      2.5 +/- 0.5 seconds.  A VT LOP failure is cleared when the VT LOP
      defect is absent for 10 +/- 0.5 seconds.

   Line Alarm Indication Signal
      A Line Alarm Indication Signal (L-AIS) is defined in ANSI T1.105.
      The following criteria are specific to the L-AIS defect:

      -  Line AIS defect is detected as a "111" pattern in bits 6, 7,
         and 8 of the K2 byte in five consecutive frames.

      -  Line AIS defect is terminated when bits 6, 7, and 8 of the K2
         byte do not contain the code "111" for five consecutive frames.

      A Line AIS failure is declared when the Line AIS defect persists
      for a period of 2.5 +/- 0.5 seconds.  A Line AIS failure is
      cleared when the Line AIS defect is absent for 10 +/- 0.5 seconds.

   STS-Path Alarm Indication Signal
      The STS-Path Alarm Indication Signal (AIS) is defined in ANSI
      T1.105 as all ones in bytes H1, H2, and H3 as well as all ones in
      the entire STS SPE.  The following criteria are specific to the
      STS-Path AIS defect:



Tesink                      Standards Track                     [Page 9]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      -  STS-Path AIS defect is detected as all ones in bytes H1 and H2
         in three contiguous frames.

      -  The STS-Path AIS defect is terminated when a valid STS Pointer
         is detected with the NDF set to "1001" (inverted) for one
         frame, or  "0110" (normal) for three contiguous frames.

      An STS-Path AIS failure is declared when the STS-Path AIS defect
      persists for 2.5 +/- 0.5 seconds.  An STS-Path AIS failure is
      cleared when the STS-Path AIS defect is absent for 10 +/- 0.5
      seconds.

   VT-Path Alarm Indication Signal
      The VT-Path Alarm Indication Signal (AIS) is only applicable for
      VTs in the floating mode of operation.  VT-Path AIS is used to
      alert the downstream VT Path Terminating Entity (PTE) of an
      upstream failure.  Upon detection of a failure, Line AIS, or STS-
      Path AIS, an STS PTE will generate downstream VT-Path AIS if the
      STS Synchronous Payload Envelope (SPE) is carrying floating VTs.
      VT-Path AIS is specified in ANSI T1.105 as all ones in bytes V1,
      V2, V3, and V4, as well as all ones in the entire VT SPE.  The
      following criteria are specific to VT-Path AIS defect:

      -  VT-Path AIS defect is detected by a VT PTE as all ones in bytes
         V1 and V2 in three contiguous VT superframes.

      -  VT-Path AIS defect is terminated when valid VT pointer with a
         valid VT size is detected with the NDF set to "1001" (inverted)
         for one VT superframe, or "0110" (normal) for three contiguous
         VT superframes are detected.

      A VT-Path AIS failure is declared when the VT-Path AIS defect
      persists for 2.5 +/- 0.5 seconds.  A VT-Path AIS failure is
      cleared when the VT-Path AIS defect is absent for 10 +/- 0.5
      seconds.

   Line Remote Defect Indication
      Line Remote Defect Indication (RDI) (aka Line FERF) signal is the
      occurrence of a "110" pattern in bit positions 6, 7, and 8 of the
      K2 byte in STS-1 #1 of the STS-N signal.  Line RDI is defined in
      ANSI T1.105.  The following criteria are specific to Line RDI
      defect:

      -  Line RDI defect is a "110" code in bits 6, 7, and 8 of the K2
         byte of in STS-1 #1 in x consecutive frames, where x = 5
         [T1.231a][T1.231b] or 10 [T1.231b].





Tesink                      Standards Track                    [Page 10]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      -  Line RDI defect is terminated when any code other than "110" is
         detected in bits 6, 7, and 8 of the K2 byte in x consecutive
         frames, where x = 5 [T1.231a][T1.231b] or 10 [T1.231b].

      A Line Remote Failure Indication (RFI) failure is declared when
      the incoming Line RDI defects lasts for 2.5 +/- 0.5 seconds.  The
      Line RFI failure is cleared when no Line RDI defects are detected
      for 10 +/- 0.5 seconds.

   STS-Path Remote Defect Indication
      STS-Path RDI (aka STS-Path FERF) signal shall be generated within
      100 milliseconds by the STS PTE upon detection of an AIS or LOP
      defect.  Transmission of the STS-Path RDI signal shall cease
      within 100 milliseconds when the STS PTE no longer detects STS-
      Path AIS or STS-Path LOP defect.  The STS-Path RDI  shall
      accurately report the presence or absence of STS-Path AIS or STS-
      Path LOP defects.  STS-Path RDI defect is defined in ANSI T1.105.
      The following requirements are specific to the STS-Path RDI
      defect:

      -  STS-Path RDI is detected by all STS PTEs.  STS-Path RDI is
         detected by the upstream STS PTE as a "1" in bit five of the
         Path Status byte (G1) for x consecutive frames, where x = 5
         [T1.231a] or 10 [T1.231b].

      -  Removal of STS-Path Remote Defect Indication is detected by a
         "0" in bit 5 of the G1 byte in x consecutive frames, where x =
         5 [T1.231a] or 10 [T1.231b].

      An STS-Path Remote Failure Indication (RFI) failure is declared
      when the incoming STS-Path RDI defects lasts for 2.5 +/- 0.5
      seconds.  The STS-Path RFI failure is cleared when no STS-Path RDI
      defects are detected for 10 +/- 0.5 seconds.

   VT-Path Remote Defect Indication
   VT Path RDI (aka VT Path FERF) signal shall be generated within 100
      milliseconds by the VT PTE upon detection of a VT-Path AIS or LOP
      defect.  Transmission of the VT-Path RDI signal shall cease within
      100 milliseconds when the VT PTE no longer detects VT-Path AIS or
      VT-Path LOP defect.  The VT-Path RDI  shall accurately report the
      presence or absence of VT-Path AIS or VT-Path LOP defects.  VT-
      Path RDI defect is defined in ANSI T1.105.  The following
      requirements are specific to VT-Path RDI defect:

      -  VT-Path RDI defect is the occurrence of a "1" in bit 4 of the
         VT-Path Overhead byte (V5) in x consecutive frames, where x = 5
         [T1.231a] or 10 [T1.231b].




Tesink                      Standards Track                    [Page 11]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      -  VT-Path RDI defect is terminated when a "0" is detected in bit
         4 of the VT-Path Overhead byte (V5) for x consecutive frames,
         where x = 5 [T1.231a] or 10 [T1.231b].

      A VT-Path Remote Failure Indication (RFI) (derived) failure is
      declared when the incoming VT-Path RDI defects lasts for 2.5 +/-
      0.5 seconds.  The VT-Path RFI failure is cleared when no VT-Path
      RDI defects are detected for 10 +/- 0.5 seconds.

   VT-Path Remote Failure Indication
      The VT-Path RFI signal is only required for the case of byte synch
      mapped DS1s where the DS1 frame bit is not mapped.  The VT-Path
      RFI is specified in ANSI T1.105, where it is currently called VT
      path yellow.  When provided, the VT-Path RFI signal is used to
      indicate the occurrence of far-end failures.  When the VT-Path RFI
      is not provided, far-end failures are derived from local timing of
      the VT-Path RDI defect.  The VT-Path RFI failure is declared
      within 5 ms of detecting the incoming VT-Path RFI Signal.  The
      VT-Path Remote Failure Indication (RFI) failure is cleared within
      50 ms of detecting the removal of the incoming VT-Path RFI signal.

   Coding Violation
      Coding Violations (CV) are Bit Interleaved Parity (BIP) errors
      that are detected in the incoming signal.  CV counters are
      incremented for each BIP error detected.  That is, each BIP-8 can
      detect up to eight errors per STS-N frame, with each error
      incrementing the CV counter.  Section CVs shall be collected using
      the BIP-8 in the B1 byte located in the Section Overhead of STS-1
      #1.  Line CVs shall be collected using the BIP-8s in B2 bytes
      located in the Line Overhead of each STS-1 (since all CVs on an
      STS-N line are counted together, this is equivalent to counting
      each error in the BIP-8*N contained in the B2 bytes of the STS-N
      Line Overhead).  Thus, on an STS-N signal, up to 8 x N CVs may
      occur in each frame.  Path CVs shall be collected using the BIP-8
      in the B3 byte of the STS-Path Overhead of the STS SPE.  VT CVs
      shall be collected using the BIP-2 in the V5 overhead byte of the
      floating VT.

   Errored Seconds
      At each layer, an Errored Second (ES) is a second with one or more
      Coding Violations at that layer OR one or more incoming defects
      (e.g., SEF, LOS, AIS, LOP) at that layer has occurred.

   Severely Errored Seconds
      According to [T1M1.3][T1.231a][TR253][GR253][T1.231b] at each
      layer, an Severely Errored Second (SES) is a second with x or more
      CVs at that layer, or a second during which at least one or more
      incoming defects at that layer has occurred.  The values of x in



Tesink                      Standards Track                    [Page 12]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      RFC 1595 [RFC1595] were based on [T1M1.3] and [TR253] (see
      Appendix B).  These values have subsequently been relaxed in
      [T1.231a][GR253][T1.231b].  In addition, according to G.826
      [G.826] SESs are measured as a percentage of errored blocks.

      To deal with these sets of definitions this memo defines an object
      sonetSESthresholdSet that determines the correct interpretation of
      SES.  For backward compatibility, if this object is not
      implemented the interpretation of Appendix B shall apply.
      Otherwise, a more recent interpretation is suggested.  An agent is
      not required to support all sets of definitions.

      Note that CV counts should be frozen during SESs.

      Note that if a manager changes the value of this object all SES
      statistics collected prior to this change shall be invalidated.

   Severely Errored Framing Seconds
      A Severely Errored Framing Second (SEFS) is a second containing
      one or more SEF events.  This counter is only counted at the
      Section Layer.

   Unavailable Seconds
      At the Line, Path, and VT layers, an unavailable second is
      calculated by counting the number of seconds that the interface is
      unavailable.  At each layer, the SONET/SDH interface is said to be
      unavailable at the onset of 10 contiguous SESs.  The 10 SESs are
      included in unavailable time.  Once unavailable, the SONET/SDH
      interface becomes available at the onset of 10 contiguous seconds
      with no SESs.  The 10 seconds with no SESs are excluded from
      unavailable time.  With respect to the SONET/SDH error counts at
      each layer, all counters at that layer are incremented while the
      SONET/SDH interface is deemed available at that layer.  While the
      interface is deemed unavailable at that layer, the only count that
      is incremented is UASs at that layer.

      Note that this definition implies that the agent cannot determine
      until after a ten second interval has passed whether a given one-
      second interval belongs to available or unavailable time.  If the
      agent chooses to update the various performance statistics in real
      time then it must be prepared to retroactively reduce the ES, SES,
      and SEFS counts by 10 and increase the UAS count by 10 when it
      determines that available time has been entered.  It must also be
      prepared to reduce the CV count by the number of violations
      counted since the onset of unavailable time.  The agent must be
      similarly prepared to retroactively decrease the UAS count by 10
      and increase the ES and CV counts as necessary upon entering
      available time.  A special case exists when the 10 second period



Tesink                      Standards Track                    [Page 13]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      leading to available or unavailable time crosses a 900 second
      statistics window boundary, as the foregoing description implies
      that the CV, ES, SES, SEFS, and UAS counts the PREVIOUS interval
      must be adjusted.  In this case successive GETs of the affected
      sonetPathIntervalSES and sonetPathIntervalUAS objects (and the
      analogous Line and VT objects also) objects will return differing
      values if the first GET occurs during the first few seconds of the
      window.

      According to ANSI T1.231 unavailable time begins at the _onset_ of
      10 contiguous severely errored seconds -- that is, unavailable
      time starts with the _first_ of the 10 contiguous SESs.  Also,
      while an interface is deemed unavailable all counters for that
      interface are frozen except for the UAS count.  It follows that an
      implementation which strictly complies with this standard must
      _not_ increment any counters other than the UAS count -- even
      temporarily -- as a result of anything that happens during those
      10 seconds.  Since changes in the signal state lag the data to
      which they apply by 10 seconds, an ANSI-compliant implementation
      must pass the one-second statistics through a 10-second delay line
      prior to updating any counters.  That can be done by performing
      the following steps at the end of each one second interval.

      i)   Read near/far end CV counter and alarm status flags from the
           hardware.

      ii)  Accumulate the CV counts for the preceding second and compare
           them to the ES and SES threshold for the layer in question.
           Update the signal state and shift the one-second CV counts
           and ES/SES flags into the 10-element delay line.  Note that
           far-end one-second statistics are to be flagged as "absent"
           during any second in which there is an incoming defect at the
           layer in question or at any lower layer.

      iii) Update the current interval statistics using the signal state
           from the _previous_ update cycle and the one-second CV counts
           and ES/SES flags shifted out of the 10-element delay line.

      This approach is further described in Appendix A.  An agent may
      choose to use this approach in lieu of retroactive adjustments to
      the counters.

      In any case, a linkDown trap shall be sent only after the agent
      has determined for certain that the unavailable state has been
      entered, but the time on the trap will be that of the first UAS
      (i.e., 10 seconds earlier).  A linkUp trap shall be handled
      similarly.




Tesink                      Standards Track                    [Page 14]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   Unequipped
      If a Path or VT connection is not provisioned (idle) the SONET
      equipment will signal this state by transmitting the Path or VT
      Signal Label as follows:  - byte C2 of the STS Path Overhead equal
      to 0 for an unequipped Path, - byte V5 of the VT Path Overhead
      equal to 0 for an unequipped VT.

   Signal Label Mismatch
      A Path or VT connection is not correctly provisioned if a received
      Path or VT Signal Label mismatch occurs.  A received Signal Label
      is considered mismatched if it does not equal either the locally
      provisioned value or the value 'equipped non-specific' (1 hex).
      Note that any received non-zero Signal Label is considered a
      locally provisioned value of 'equipped non-specific'.  Only in-
      service, provisioned Path Terminating equipment can detect
      mismatched Signal labels.  It is considered provisioned if it has
      been configured for a mapping and has been assigned signals to and
      from which the mapping takes place.  While a Path is unequipped or
      has mismatched signal labels ES/SES counts continue, but these
      conditions do not themselves contribute to ES/SES.

   Circuit Identifier
      This is a character string specified by the circuit vendor, and is
      useful when communicating with the vendor during the
      troubleshooting process.

4.  Object Definitions

   SONET-MIB DEFINITIONS ::= BEGIN

   IMPORTS
       MODULE-IDENTITY, OBJECT-TYPE,
       Integer32, transmission
             FROM SNMPv2-SMI
       DisplayString, TruthValue
             FROM SNMPv2-TC
       MODULE-COMPLIANCE, OBJECT-GROUP
             FROM SNMPv2-CONF
       ifIndex
             FROM IF-MIB
       PerfCurrentCount, PerfIntervalCount
             FROM PerfHist-TC-MIB;

   --  This is the MIB module for the SONET/SDH Interface objects.

   sonetMIB MODULE-IDENTITY
       LAST-UPDATED "200308110000Z"
       ORGANIZATION "IETF AToM MIB Working Group"



Tesink                      Standards Track                    [Page 15]
^L
RFC 3592                   SONET/SDH Objects              September 2003


       CONTACT-INFO
         "WG charter:
            http://www.ietf.org/html.charters/atommib-charter.html

          Mailing Lists:
            General Discussion: atommib@research.telcordia.com
            To Subscribe: atommib-request@research.telcordia.com

          Kaj Tesink
          Telcordia Technologies
          Tel: (732) 758-5254
          Fax: (732) 758-2269
          E-mail: kaj@research.telcordia.com."
       DESCRIPTION
         "The MIB module to describe SONET/SDH interface objects.

          Copyright (C) The Internet Society (2003).  This version
          of this MIB module is part of RFC 3592;  see the RFC
          itself for full legal notices."
       REVISION      "200308110000Z"
       DESCRIPTION
           "The key changes made to this MIB module
           since its publication in RFC 2558
           are as follows.

           (1) Corrected typographical error
               (bellcore1991(2) in sonetSESthresholdSet)

           (2) Added support for sts192cSTM64(6) and
               sts768cSTM256(7) in sonetPathCurrentWidth

           (3) Corrected description of the applicability
               of VTs for SDH for improved accuracy

           (4) Added clarification in the SES description that
               CV counts should be frozen during SESs

           (5) Corrected typographical errors:
               - Line Alarm Indication Signal description of the
                 Terminology section (20.5 --> 2.5 seconds)
               - In the Terminology section
                 sonetSESThresholdSet  --> sonetSESthresholdSet
               "
       REVISION      "199810190000Z"
       DESCRIPTION
           "The RFC 2558 version of this MIB module.





Tesink                      Standards Track                    [Page 16]
^L
RFC 3592                   SONET/SDH Objects              September 2003


           The key changes made to this MIB module
           since its initial publication in RFC 1595
           are as follows.

           (1) The MODULE-IDENTITY has been updated to reflect the
               changes to the MIB.

           (2) Where applicable, the textual conventions
               PerfCurrentCount and PerfIntervalCount from
               PerfHist-TC-MIB have been used in place of Gauge32.

           (3) An agent now has the option to delay updates to
               the various performance counts in lieu of performing
               retroactive adjustments upon entering into or exiting
               from unavailable time. This implementation option is
               described in Appendix A of this memo.

           (4) In order to make the SONET-MIB more useful for
               circuit provisioning, the formerly read-only objects
               sonetMediumType, sonetMediumLineCoding,
               sonetMediumLineType, and sonetMediumCircuitIdentifier
               have been given a MAX-ACCESS of read-write. The
               MIN-ACCESS remains read-only.

           (5) The DESCRIPTION clause for sonetMediumTimeElapsed has
               been updated to describe its behaviour if the duration
               of the current interval exceeds the maximum value.

           (6) The DESCRIPTION clause for sonetMediumValidIntervals
               has been updated to describe its behaviour when some
               intervals may be unavailable, and the object
               sonetMediumInvalidIntervals has been added to keep
               count of the number of missing intervals (if any).

           (7) The object sonetMediumLoopbackConfig has been added
               to enable or disable loopback configurations.

           (8) Because the error count thresholds for declaring
               severely errored seconds that are specified in ANSI
               T1.231-1993, ITU-T G.826-1995, and ANSI T1.231-1997
               are all different from each other and from the thresholds
               specified in RFC 1595, an enumerated INTEGER object
               sonetSESthresholdSet has been added to allow an agent
               to specify which threshold set is in use. Text has
               been added to Section 3 stating that if this object is
               not implemented the thresholds specified in RFC 1595
               should be assumed, and the table containing those
               thresholds has been moved to Appendix B of this memo.



Tesink                      Standards Track                    [Page 17]
^L
RFC 3592                   SONET/SDH Objects              September 2003


           (9) A column with SYNTAX TruthValue has been added to each
               interval table.  The purpose of the additional column
               is to indicate, for each interval, whether the data
               is valid in the sense intended by ANSI T1.231 clause
               9.1.2.2 [T1.231a][T1.231b]. The objects in question are:

                   sonetSectionIntervalValidData
                   sonetLineIntervalValidData
                   sonetFarEndLineIntervalValidData
                   sonetPathIntervalValidData
                   sonetFarEndPathIntervalValidData
                   sonetVTIntervalValidData
                   sonetFarEndVTIntervalValidData

          (10) The ranges for sonetPathCurrentStatus and
               sonetVTCurrentStatus have been made consistent
               with the DESCRIPTION clauses.

          (11) The conformance information has been updated. Previous
               conformance information from RFC 1595 has been
               deprecated. Some typographical errors in the deprecated
               section have been corrected in order to prevent
               MIB compilation errors."

       REVISION      "199401030000Z"
       DESCRIPTION
           "The RFC 1595 version of this MIB module."

       ::= { transmission 39 }

   --  This is the MIB module for the SONET/SDH objects

   sonetObjects      OBJECT IDENTIFIER ::= { sonetMIB 1 }

   sonetObjectsPath  OBJECT IDENTIFIER ::= { sonetMIB 2 }

   sonetObjectsVT    OBJECT IDENTIFIER ::= { sonetMIB 3 }

   -- groups in the SONET/SDH MIB module

   sonetMedium        OBJECT IDENTIFIER ::= { sonetObjects 1 }

   sonetSection       OBJECT IDENTIFIER ::= { sonetObjects 2 }

   sonetLine          OBJECT IDENTIFIER ::= { sonetObjects 3 }

   sonetFarEndLine    OBJECT IDENTIFIER ::= { sonetObjects 4 }




Tesink                      Standards Track                    [Page 18]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetPath          OBJECT IDENTIFIER ::= { sonetObjectsPath 1 }

   sonetFarEndPath    OBJECT IDENTIFIER ::= { sonetObjectsPath 2 }

   sonetVT            OBJECT IDENTIFIER ::= { sonetObjectsVT 1 }

   sonetFarEndVT      OBJECT IDENTIFIER ::= { sonetObjectsVT 2 }

   -- the SONET/SDH Medium group

   -- SONET/SDH interfaces for some applications may be electrical
   -- interfaces and not optical interfaces.  This group handles
   -- the configuration information for both optical SONET/SDH
   -- interfaces and electrical SONET/SDH interfaces.

   sonetMediumTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetMediumEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Medium table."
        ::= { sonetMedium 1 }

   sonetMediumEntry OBJECT-TYPE
       SYNTAX  SonetMediumEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the SONET/SDH Medium table."
       INDEX   { ifIndex }
        ::= { sonetMediumTable 1 }

   SonetMediumEntry ::=
       SEQUENCE {
            sonetMediumType               INTEGER,
            sonetMediumTimeElapsed        Integer32,
            sonetMediumValidIntervals     Integer32,
            sonetMediumLineCoding         INTEGER,
            sonetMediumLineType           INTEGER,
            sonetMediumCircuitIdentifier  DisplayString,
            sonetMediumInvalidIntervals   Integer32,
            sonetMediumLoopbackConfig     BITS
       }

   sonetMediumType OBJECT-TYPE
       SYNTAX  INTEGER  {
                  sonet(1),
                  sdh(2)



Tesink                      Standards Track                    [Page 19]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable identifies whether a SONET
          or a SDH signal is used across this interface."
       ::= { sonetMediumEntry 1 }

   sonetMediumTimeElapsed OBJECT-TYPE
       SYNTAX  Integer32 (1..900)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The number of seconds, including partial seconds,
          that have elapsed since the beginning of the current
          measurement period. If, for some reason, such as an
          adjustment in the system's time-of-day clock, the
          current interval exceeds the maximum value, the
          agent will return the maximum value."
       ::= { sonetMediumEntry 2 }

   sonetMediumValidIntervals OBJECT-TYPE
       SYNTAX  Integer32 (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The number of previous 15-minute intervals
          for which data was collected.
          A SONET/SDH interface must be capable
          of supporting at least n intervals.
          The minimum value of n is 4.
          The default of n is 32.
          The maximum value of n is 96.
          The value will be <n> unless the measurement was
          (re-)started within the last (<n>*15) minutes, in which
          case the value will be the number of complete 15
          minute intervals for which the agent has at least
          some data. In certain cases (e.g., in the case
          where the agent is a proxy) it is possible that some
          intervals are unavailable.  In this case, this
          interval is the maximum interval number for
          which data is available. "
       ::= { sonetMediumEntry 3 }

   sonetMediumLineCoding OBJECT-TYPE
       SYNTAX  INTEGER {
                   sonetMediumOther(1),
                   sonetMediumB3ZS(2),



Tesink                      Standards Track                    [Page 20]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                   sonetMediumCMI(3),
                   sonetMediumNRZ(4),
                   sonetMediumRZ(5)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable describes the line coding for
          this interface. The B3ZS and CMI are used for
          electrical SONET/SDH signals (STS-1 and STS-3).
          The Non-Return to Zero (NRZ) and the Return
          to Zero are used for optical SONET/SDH signals."
       ::= { sonetMediumEntry 4 }

   sonetMediumLineType OBJECT-TYPE
       SYNTAX  INTEGER {
                   sonetOther(1),
                   sonetShortSingleMode(2),
                   sonetLongSingleMode(3),
                   sonetMultiMode(4),
                   sonetCoax(5),
                   sonetUTP(6)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable describes the line type for
          this interface. The line types are
          Short and Long Range
          Single Mode fiber or Multi-Mode fiber interfaces,
          and coax and UTP for electrical interfaces.  The
          value sonetOther should be used when the Line Type is
          not one of the listed values."
       ::= { sonetMediumEntry 5 }

   sonetMediumCircuitIdentifier OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..255))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable contains the transmission
          vendor's circuit identifier, for the
          purpose of facilitating troubleshooting.
          Note that the circuit identifier, if available,
          is also represented by ifPhysAddress."
       ::= { sonetMediumEntry 6 }





Tesink                      Standards Track                    [Page 21]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetMediumInvalidIntervals OBJECT-TYPE
       SYNTAX  Integer32 (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The number of intervals in the range from
           0 to sonetMediumValidIntervals for which no
           data is available. This object will typically
           be zero except in cases where the data for some
           intervals are not available (e.g., in proxy
           situations)."
       ::= { sonetMediumEntry 7 }

   sonetMediumLoopbackConfig OBJECT-TYPE
       SYNTAX      BITS {
                     sonetNoLoop(0),
                     sonetFacilityLoop(1),
                     sonetTerminalLoop(2),
                     sonetOtherLoop(3) }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
          "The current loopback state of the SONET/SDH interface.  The
           values mean:

             sonetNoLoop
                Not in the loopback state. A device that is not
                capable of performing a loopback on this interface
                shall always return this value.

             sonetFacilityLoop
                The received signal at this interface is looped back
                out through the corresponding transmitter in the return
                direction.

             sonetTerminalLoop
                The signal that is about to be transmitted is connected
                to the associated incoming receiver.

             sonetOtherLoop
                Loopbacks that are not defined here."

       ::= { sonetMediumEntry 8 }

   sonetSESthresholdSet    OBJECT-TYPE
       SYNTAX   INTEGER {
                  other(1),
                  bellcore1991(2),



Tesink                      Standards Track                    [Page 22]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                  ansi1993(3),
                  itu1995(4),
                  ansi1997(5)
                         }
       MAX-ACCESS      read-write
       STATUS          current
       DESCRIPTION
         "An enumerated integer indicating which
          recognized set of SES thresholds that
          the agent uses for determining severely
          errored seconds and unavailable time.

          other(1)
            None of the following.

          bellcore1991(2)
            Bellcore TR-NWT-000253, 1991 [TR253], or
            ANSI T1M1.3/93-005R2, 1993 [T1M1.3].
            See also Appendix B.

          ansi1993(3)
            ANSI T1.231, 1993 [T1.231a], or
            Bellcore GR-253-CORE, Issue 2, 1995 [GR253]

          itu1995(4)
            ITU Recommendation G.826, 1995 [G.826]

          ansi1997(5)
            ANSI T1.231, 1997 [T1.231b]

          If a manager changes the value of this
          object then the SES statistics collected
          prior to this change must be invalidated."
        ::= { sonetMedium 2 }

   -- the SONET/SDH Section group

   -- this group consists of 2 tables:
   -- - the SONET/SDH Section Current Table
   -- - the SONET/SDH Section Interval Table

   -- the SONET/SDH Section Current Table

   -- The SONET/SDH Section
   -- current table contains various statistics
   -- being collected for the current 15 minute interval.





Tesink                      Standards Track                    [Page 23]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetSectionCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetSectionCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Section Current table."
        ::= { sonetSection 1 }

   sonetSectionCurrentEntry OBJECT-TYPE
       SYNTAX  SonetSectionCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the SONET/SDH Section Current table."
       INDEX   { ifIndex }
        ::= { sonetSectionCurrentTable 1 }

   SonetSectionCurrentEntry ::=
       SEQUENCE {
           sonetSectionCurrentStatus   Integer32,
           sonetSectionCurrentESs      PerfCurrentCount,
           sonetSectionCurrentSESs     PerfCurrentCount,
           sonetSectionCurrentSEFSs    PerfCurrentCount,
           sonetSectionCurrentCVs      PerfCurrentCount
       }

   sonetSectionCurrentStatus OBJECT-TYPE
       SYNTAX  Integer32 (1..6)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates the
          status of the interface.
          The sonetSectionCurrentStatus
          is a bit map represented
          as a sum, therefore,
          it can represent multiple defects
          simultaneously.
          The sonetSectionNoDefect should be
          set if and only if
          no other flag is set.

          The various bit positions are:
                1   sonetSectionNoDefect
                2   sonetSectionLOS
                4   sonetSectionLOF"
        ::= { sonetSectionCurrentEntry 1 }




Tesink                      Standards Track                    [Page 24]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetSectionCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of Errored
          Seconds encountered by a SONET/SDH
          Section in the current 15 minute interval."
        ::= { sonetSectionCurrentEntry 2 }

   sonetSectionCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Severely Errored Seconds
          encountered by a SONET/SDH Section in the current 15
          minute interval."
        ::= { sonetSectionCurrentEntry 3 }

   sonetSectionCurrentSEFSs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Severely Errored Framing Seconds
          encountered by a SONET/SDH Section in the current
          15 minute interval."
       ::= { sonetSectionCurrentEntry 4 }

   sonetSectionCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of Coding
          Violations encountered by a
          SONET/SDH Section in the current 15 minute interval."
        ::= { sonetSectionCurrentEntry 5 }

   -- the SONET/SDH Section Interval Table

   -- The SONET/SDH Section Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of



Tesink                      Standards Track                    [Page 25]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetSectionIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetSectionIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Section Interval table."
        ::= { sonetSection 2 }

   sonetSectionIntervalEntry OBJECT-TYPE
       SYNTAX  SonetSectionIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the SONET/SDH Section Interval table."
       INDEX   { ifIndex,
                 sonetSectionIntervalNumber }
        ::= { sonetSectionIntervalTable 1 }

   SonetSectionIntervalEntry ::=
       SEQUENCE {
            sonetSectionIntervalNumber  Integer32,
            sonetSectionIntervalESs     PerfIntervalCount,
            sonetSectionIntervalSESs    PerfIntervalCount,
            sonetSectionIntervalSEFSs   PerfIntervalCount,
            sonetSectionIntervalCVs     PerfIntervalCount,
            sonetSectionIntervalValidData  TruthValue
       }

   sonetSectionIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "A number between 1 and 96, which identifies the
         interval for which the set of statistics is available.
         The interval identified by 1 is the most recently
         completed 15 minute interval,
         and the interval identified
         by N is the interval immediately preceding the
         one identified
         by N-1."
        ::= { sonetSectionIntervalEntry 1 }



Tesink                      Standards Track                    [Page 26]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetSectionIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Errored Seconds encountered
          by a SONET/SDH Section in a
          particular 15-minute interval
          in the past 24 hours."
        ::= { sonetSectionIntervalEntry 2 }

   sonetSectionIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Severely Errored Seconds
          encountered by a SONET/SDH Section in a
          particular 15-minute interval
          in the past 24 hours."
       ::= { sonetSectionIntervalEntry 3 }

   sonetSectionIntervalSEFSs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Severely Errored Framing Seconds
          encountered by a SONET/SDH Section in a
          particular 15-minute interval
          in the past 24 hours."
       ::= { sonetSectionIntervalEntry 4 }

   sonetSectionIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of Coding
          Violations encountered by a
          SONET/SDH Section in a particular 15-minute interval
          in the past 24 hours."
       ::= { sonetSectionIntervalEntry 5 }





Tesink                      Standards Track                    [Page 27]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetSectionIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetSectionIntervalEntry 6 }

   -- the SONET/SDH Line group

   -- this group consists of 2 tables:
   -- - the SONET/SDH Line Current Table
   -- - the SONET/SDH Line Interval Table

   -- the SONET/SDH Line Current Table

   -- The SONET/SDH Line
   -- current table contains various statistics
   -- being collected for the current 15 minute interval.

   sonetLineCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetLineCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "The SONET/SDH Line Current table."
       ::= { sonetLine 1 }

   sonetLineCurrentEntry OBJECT-TYPE
       SYNTAX  SonetLineCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "An entry in the SONET/SDH Line Current table."
       INDEX   { ifIndex }
       ::= { sonetLineCurrentTable 1 }

   SonetLineCurrentEntry ::=
       SEQUENCE {
            sonetLineCurrentStatus    Integer32,
            sonetLineCurrentESs       PerfCurrentCount,
            sonetLineCurrentSESs      PerfCurrentCount,
            sonetLineCurrentCVs       PerfCurrentCount,
            sonetLineCurrentUASs      PerfCurrentCount
        }





Tesink                      Standards Track                    [Page 28]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetLineCurrentStatus OBJECT-TYPE
       SYNTAX  Integer32 (1..6)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates the
          status of the interface.
          The sonetLineCurrentStatus
          is a bit map represented
          as a sum, therefore,
          it can represent multiple defects
          simultaneously.
          The sonetLineNoDefect should be
          set if and only if
          no other flag is set.

          The various bit positions are:
           1   sonetLineNoDefect
           2   sonetLineAIS
           4   sonetLineRDI"
        ::= { sonetLineCurrentEntry 1 }

   sonetLineCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Errored
        Seconds encountered by a SONET/SDH
        Line in the current 15 minute interval."
       ::= { sonetLineCurrentEntry 2 }

   sonetLineCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
       ::= { sonetLineCurrentEntry 3 }

   sonetLineCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current



Tesink                      Standards Track                    [Page 29]
^L
RFC 3592                   SONET/SDH Objects              September 2003


       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH Line in the current 15 minute interval."
       ::= { sonetLineCurrentEntry 4 }

   sonetLineCurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a SONET/SDH Line in the current 15
        minute
        interval."
       ::= { sonetLineCurrentEntry 5 }

   -- the SONET/SDH Line Interval Table

   -- The SONET/SDH Line Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetLineIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetLineIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Line Interval table."
        ::= { sonetLine 2 }

   sonetLineIntervalEntry OBJECT-TYPE
       SYNTAX  SonetLineIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the SONET/SDH Line Interval table."
      INDEX   { ifIndex,
                sonetLineIntervalNumber }
      ::= { sonetLineIntervalTable 1 }




Tesink                      Standards Track                    [Page 30]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   SonetLineIntervalEntry ::=
       SEQUENCE {
           sonetLineIntervalNumber    Integer32,
           sonetLineIntervalESs       PerfIntervalCount,
           sonetLineIntervalSESs      PerfIntervalCount,
           sonetLineIntervalCVs       PerfIntervalCount,
           sonetLineIntervalUASs      PerfIntervalCount,
           sonetLineIntervalValidData TruthValue
       }

   sonetLineIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "A number between 1 and 96, which identifies the
           interval for which the set of statistics is available.
           The interval identified by 1 is the most recently
           completed 15 minute interval,
           and the interval identified
           by N is the interval immediately preceding the
           one identified
           by N-1."
        ::= { sonetLineIntervalEntry 1 }

   sonetLineIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Errored Seconds encountered
          by a SONET/SDH Line in a
          particular 15-minute interval
          in the past 24 hours."
        ::= { sonetLineIntervalEntry 2 }

   sonetLineIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "The counter associated with the number of
          Severely Errored Seconds
          encountered by a SONET/SDH Line in a
          particular 15-minute interval
          in the past 24 hours."
         ::= { sonetLineIntervalEntry 3 }



Tesink                      Standards Track                    [Page 31]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetLineIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
         "The counter associated with the number of Coding
         Violations encountered by a
         SONET/SDH Line in a
         particular 15-minute interval
         in the past 24 hours."
       ::= { sonetLineIntervalEntry 4 }

   sonetLineIntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
         "The counter associated with the
         number of Unavailable Seconds
         encountered by a SONET/SDH Line in
         a particular 15-minute interval
         in the past 24 hours."
       ::= { sonetLineIntervalEntry 5 }

   sonetLineIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetLineIntervalEntry 6 }

   -- The SONET/SDH Far End Line group.
   -- This group may only be implemented by SONET/SDH (LTEs)
   -- systems that provide for a far end block error (FEBE)
   -- information at the SONET/SDH Line Layer.

   -- This group consists of two tables:
   --    SONET/SDH Far End Line Current Table
   --    SONET/SDH Far End Line Interval Table

   -- The SONET/SDH Far End Line Current Table

   -- The SONET/SDH Far End Line Current table contains
   -- various statistics being
   -- collected for the current 15 minute interval.
   -- The statistics are collected from the far end



Tesink                      Standards Track                    [Page 32]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   -- block error code (FEBE)
   -- within the third Z2 byte of the Line Overhead
   -- in Broadband ISDN applications.
   -- The definitions are the same as described for
   -- the near-end information.

   sonetFarEndLineCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndLineCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "The SONET/SDH Far End Line Current table."
       ::= { sonetFarEndLine 1 }

   sonetFarEndLineCurrentEntry OBJECT-TYPE
       SYNTAX  SonetFarEndLineCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "An entry in the SONET/SDH Far End Line Current table."
       INDEX   { ifIndex }
       ::= { sonetFarEndLineCurrentTable 1 }

   SonetFarEndLineCurrentEntry ::=
       SEQUENCE {
           sonetFarEndLineCurrentESs       PerfCurrentCount,
           sonetFarEndLineCurrentSESs      PerfCurrentCount,
           sonetFarEndLineCurrentCVs       PerfCurrentCount,
           sonetFarEndLineCurrentUASs      PerfCurrentCount
          }

   sonetFarEndLineCurrentESs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of Far
          End Errored Seconds encountered by a SONET/SDH
          interface in the current 15 minute interval."
      ::= { sonetFarEndLineCurrentEntry 1 }

   sonetFarEndLineCurrentSESs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Severely Errored Seconds



Tesink                      Standards Track                    [Page 33]
^L
RFC 3592                   SONET/SDH Objects              September 2003


          encountered by a SONET/SDH Medium/Section/Line
          interface in the current 15 minute
          interval."
      ::= { sonetFarEndLineCurrentEntry 2 }

   sonetFarEndLineCurrentCVs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Coding Violations reported via
          the far end block error count
          encountered by a
          SONET/SDH Medium/Section/Line
          interface in the current 15 minute interval."
      ::= { sonetFarEndLineCurrentEntry 3 }

   sonetFarEndLineCurrentUASs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH Medium/Section/Line
          interface in the current 15 minute interval."
      ::= { sonetFarEndLineCurrentEntry 4 }

   -- The SONET/SDH Far End Line Interval Table

   -- The SONET/SDH Far End Line Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetFarEndLineIntervalTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF SonetFarEndLineIntervalEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
         "The SONET/SDH Far End Line Interval table."



Tesink                      Standards Track                    [Page 34]
^L
RFC 3592                   SONET/SDH Objects              September 2003


      ::= { sonetFarEndLine 2 }

   sonetFarEndLineIntervalEntry OBJECT-TYPE
      SYNTAX  SonetFarEndLineIntervalEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
        "An entry in the SONET/SDH Far
        End Line Interval table."
      INDEX   { ifIndex,
                sonetFarEndLineIntervalNumber }
      ::= { sonetFarEndLineIntervalTable 1 }

   SonetFarEndLineIntervalEntry ::=
       SEQUENCE {
            sonetFarEndLineIntervalNumber    Integer32,
            sonetFarEndLineIntervalESs       PerfIntervalCount,
            sonetFarEndLineIntervalSESs      PerfIntervalCount,
            sonetFarEndLineIntervalCVs       PerfIntervalCount,
            sonetFarEndLineIntervalUASs      PerfIntervalCount,
            sonetFarEndLineIntervalValidData TruthValue
       }

   sonetFarEndLineIntervalNumber OBJECT-TYPE
      SYNTAX  Integer32 (1..96)
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
            "A number between 1 and 96, which identifies the
            interval for which the set of statistics is available.
            The interval identified by 1 is the most recently
            completed 15 minute interval,
            and the interval identified
            by N is the interval immediately preceding the
            one identified
            by N-1."
      ::= { sonetFarEndLineIntervalEntry 1 }

   sonetFarEndLineIntervalESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Errored Seconds encountered
           by a SONET/SDH Line
           interface in a particular 15-minute interval
           in the past 24 hours."



Tesink                      Standards Track                    [Page 35]
^L
RFC 3592                   SONET/SDH Objects              September 2003


     ::= { sonetFarEndLineIntervalEntry 2 }

   sonetFarEndLineIntervalSESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Severely Errored Seconds
           encountered by a SONET/SDH Line
           interface in a particular 15-minute interval
           in the past 24 hours."
     ::= { sonetFarEndLineIntervalEntry 3 }

   sonetFarEndLineIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH Line
            interface in a particular 15-minute interval
            in the past 24 hours."
       ::= { sonetFarEndLineIntervalEntry 4 }

   sonetFarEndLineIntervalUASs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH Line
          interface in a particular 15-minute interval
          in the past 24 hours."
      ::= { sonetFarEndLineIntervalEntry 5 }

   sonetFarEndLineIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."



Tesink                      Standards Track                    [Page 36]
^L
RFC 3592                   SONET/SDH Objects              September 2003


       ::= { sonetFarEndLineIntervalEntry 6 }

   -- the SONET/SDH Path group

   -- this group consists of 2 tables:
   -- - the SONET/SDH Path Current Table
   -- - the SONET/SDH Path Interval Table

   -- the SONET/SDH Path Current Table

   -- The SONET/SDH Path
   -- current table contains various statistics
   -- being collected for the current 15 minute interval.

   sonetPathCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH Path Current table."
   ::= { sonetPath 1 }

   sonetPathCurrentEntry OBJECT-TYPE
       SYNTAX  SonetPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH Path Current table."
       INDEX   { ifIndex }
   ::= { sonetPathCurrentTable 1 }

   SonetPathCurrentEntry ::=
       SEQUENCE {
           sonetPathCurrentWidth      INTEGER,
           sonetPathCurrentStatus     Integer32,
           sonetPathCurrentESs        PerfCurrentCount,
           sonetPathCurrentSESs       PerfCurrentCount,
           sonetPathCurrentCVs        PerfCurrentCount,
           sonetPathCurrentUASs       PerfCurrentCount
       }

   sonetPathCurrentWidth OBJECT-TYPE
       SYNTAX  INTEGER  {
               sts1(1),
               sts3cSTM1(2),
               sts12cSTM4(3),
               sts24c(4),
               sts48cSTM16(5),



Tesink                      Standards Track                    [Page 37]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               sts192cSTM64(6),
               sts768cSTM256(7)
        }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
        "A value that indicates the type of the SONET/SDH
        Path.  For SONET, the assigned types are
        the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.
        STS-1 is equal to 51.84 Mbps.  For SDH, the assigned
        types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
   ::= { sonetPathCurrentEntry 1 }

   sonetPathCurrentStatus OBJECT-TYPE
       SYNTAX  Integer32 (1..62)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
         "This variable indicates the
         status of the interface.
         The sonetPathCurrentStatus
         is a bit map represented
         as a sum, therefore,
         it can represent multiple defects
         simultaneously.
         The sonetPathNoDefect should be
         set if and only if
         no other flag is set.

         The various bit positions are:
            1   sonetPathNoDefect
            2   sonetPathSTSLOP
            4   sonetPathSTSAIS
            8   sonetPathSTSRDI
           16   sonetPathUnequipped
           32   sonetPathSignalLabelMismatch"
   ::= { sonetPathCurrentEntry 2 }

   sonetPathCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Errored
        Seconds encountered by a SONET/SDH
        Path in the current 15 minute interval."
   ::= { sonetPathCurrentEntry 3 }




Tesink                      Standards Track                    [Page 38]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetPathCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Path in the current 15
        minute
        interval."
   ::= { sonetPathCurrentEntry 4 }

   sonetPathCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH Path in the current 15 minute interval."
   ::= { sonetPathCurrentEntry 5 }

   sonetPathCurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a Path in the current
        15 minute interval."
   ::= { sonetPathCurrentEntry 6 }

   -- the SONET/SDH Path Interval Table

   -- The SONET/SDH Path Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.







Tesink                      Standards Track                    [Page 39]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetPathIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetPathIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH Path Interval table."
   ::= { sonetPath 2 }

   sonetPathIntervalEntry OBJECT-TYPE
       SYNTAX  SonetPathIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH Path Interval table."
       INDEX   { ifIndex,
                 sonetPathIntervalNumber }
   ::= { sonetPathIntervalTable 1 }

   SonetPathIntervalEntry ::=
       SEQUENCE {
            sonetPathIntervalNumber     Integer32,
            sonetPathIntervalESs        PerfIntervalCount,
            sonetPathIntervalSESs       PerfIntervalCount,
            sonetPathIntervalCVs        PerfIntervalCount,
            sonetPathIntervalUASs       PerfIntervalCount,
            sonetPathIntervalValidData  TruthValue
       }

   sonetPathIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "A number between 1 and 96, which identifies the
          interval for which the set of statistics is available.
          The interval identified by 1 is the most recently
          completed 15 minute interval,
          and the interval identified
          by N is the interval immediately preceding the
          one identified
          by N-1."
   ::= { sonetPathIntervalEntry 1 }

   sonetPathIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION



Tesink                      Standards Track                    [Page 40]
^L
RFC 3592                   SONET/SDH Objects              September 2003


        "The counter associated with the number of
        Errored Seconds encountered
        by a SONET/SDH Path in a
        particular 15-minute interval
        in the past 24 hours."
   ::= { sonetPathIntervalEntry 2 }

   sonetPathIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH Path in
        a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetPathIntervalEntry 3 }

   sonetPathIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH Path in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetPathIntervalEntry 4 }

   sonetPathIntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a Path in a
        particular 15-minute interval
        in the past 24 hours."
   ::= { sonetPathIntervalEntry 5 }

   sonetPathIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this



Tesink                      Standards Track                    [Page 41]
^L
RFC 3592                   SONET/SDH Objects              September 2003


           interval is valid."
       ::= { sonetPathIntervalEntry 6 }

   -- The SONET/SDH Far End Path group

   -- This group consists of two tables:
   --  - SONET/SDH Far End Path Current Table
   --  - SONET/SDH Far End Path Interval Table

   -- The SONET/SDH Far End Path Current Table

   -- The SONET/SDH Far End Path Current table
   -- contains various statistics
   -- being collected for the current 15 minute interval.
   -- The statistics are collected from
   -- the far end block error code
   -- (FEBE) within the G1 byte of the Path Overhead.
   -- The definitions are the same as described for
   -- the near-end information.

   sonetFarEndPathCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
            "The SONET/SDH Far End Path Current table."
       ::= { sonetFarEndPath 1 }

   sonetFarEndPathCurrentEntry OBJECT-TYPE
       SYNTAX  SonetFarEndPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
            "An entry in the SONET/SDH Far End Path Current table."
       INDEX   { ifIndex }
       ::= { sonetFarEndPathCurrentTable 1 }

   SonetFarEndPathCurrentEntry ::=
       SEQUENCE {
           sonetFarEndPathCurrentESs       PerfCurrentCount,
           sonetFarEndPathCurrentSESs      PerfCurrentCount,
           sonetFarEndPathCurrentCVs       PerfCurrentCount,
           sonetFarEndPathCurrentUASs      PerfCurrentCount
       }







Tesink                      Standards Track                    [Page 42]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetFarEndPathCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of Far
            End Errored Seconds encountered by a SONET/SDH
            interface in the current 15 minute interval."
       ::= { sonetFarEndPathCurrentEntry 1 }

   sonetFarEndPathCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Severely Errored Seconds
            encountered by a SONET/SDH Path
            interface in the current 15 minute
            interval."
       ::= { sonetFarEndPathCurrentEntry 2 }

   sonetFarEndPathCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH Path interface in
            the current 15 minute interval."
       ::= { sonetFarEndPathCurrentEntry 3 }

   sonetFarEndPathCurrentUASs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH Path interface in
          the current 15 minute interval."
      ::= { sonetFarEndPathCurrentEntry 4 }





Tesink                      Standards Track                    [Page 43]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   -- The SONET/SDH Far End Path Interval Table

   -- The SONET/SDH Far End Path Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetFarEndPathIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndPathIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "The SONET/SDH Far End Path Interval table."
       ::= { sonetFarEndPath 2 }

   sonetFarEndPathIntervalEntry OBJECT-TYPE
       SYNTAX  SonetFarEndPathIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the SONET/SDH Far
          End Path Interval table."
       INDEX   { ifIndex,
                 sonetFarEndPathIntervalNumber }
       ::= { sonetFarEndPathIntervalTable 1 }

   SonetFarEndPathIntervalEntry ::=
       SEQUENCE {
            sonetFarEndPathIntervalNumber     Integer32,
            sonetFarEndPathIntervalESs        PerfIntervalCount,
            sonetFarEndPathIntervalSESs       PerfIntervalCount,
            sonetFarEndPathIntervalCVs        PerfIntervalCount,
            sonetFarEndPathIntervalUASs       PerfIntervalCount,
            sonetFarEndPathIntervalValidData  TruthValue
       }

   sonetFarEndPathIntervalNumber OBJECT-TYPE
      SYNTAX  Integer32 (1..96)
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
           "A number between 1 and 96, which identifies the
           interval for which the set of statistics is available.



Tesink                      Standards Track                    [Page 44]
^L
RFC 3592                   SONET/SDH Objects              September 2003


           The interval identified by 1 is the most recently
           completed 15 minute interval,
           and the interval identified
           by N is the interval immediately preceding the
           one identified
           by N-1."
      ::= { sonetFarEndPathIntervalEntry 1 }

   sonetFarEndPathIntervalESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Errored Seconds encountered
           by a SONET/SDH Path interface in a
           particular 15-minute interval
           in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 2 }

   sonetFarEndPathIntervalSESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Severely Errored Seconds
           encountered by a SONET/SDH Path interface
           in a particular 15-minute interval
           in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 3 }

   sonetFarEndPathIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH Path interface
            in a particular 15-minute interval
            in the past 24 hours."
       ::= { sonetFarEndPathIntervalEntry 4 }






Tesink                      Standards Track                    [Page 45]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetFarEndPathIntervalUASs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH Path interface in
          a particular 15-minute interval
          in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 5 }

   sonetFarEndPathIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetFarEndPathIntervalEntry 6 }

   -- the SONET/SDH Virtual Tributary group

   -- this group consists of 2 tables:
   -- - the SONET/SDH VT Current Table
   -- - the SONET/SDH VT Interval Table

   -- Corresponding SDH signals for SONET VTs are
   -- as follows:

   -- A VT1.5 = TU11
   -- A VT2 = TU12
   -- A VT3 = none
   -- none  = TU3
   -- A VT6 = TU2

   -- the SONET/SDH VT Current Table

   -- The SONET/SDH VT current table
   -- contains various statistics
   -- being collected for the
   -- current 15 minute interval.








Tesink                      Standards Track                    [Page 46]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetVTCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH VT Current table."
   ::= { sonetVT 1 }

   sonetVTCurrentEntry OBJECT-TYPE
       SYNTAX  SonetVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH VT Current table."
       INDEX   { ifIndex }
   ::= { sonetVTCurrentTable 1 }

   SonetVTCurrentEntry ::=
       SEQUENCE {
           sonetVTCurrentWidth      INTEGER,
           sonetVTCurrentStatus     Integer32,
           sonetVTCurrentESs        PerfCurrentCount,
           sonetVTCurrentSESs       PerfCurrentCount,
           sonetVTCurrentCVs        PerfCurrentCount,
           sonetVTCurrentUASs       PerfCurrentCount
       }

   sonetVTCurrentWidth OBJECT-TYPE
       SYNTAX  INTEGER {
               vtWidth15VC11(1),
               vtWidth2VC12(2),
               vtWidth3(3),
               vtWidth6VC2(4),
               vtWidth6c(5)
            }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "A value that indicates the type of the SONET
        VT and SDH VC.  Assigned widths are
        VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
   ::= { sonetVTCurrentEntry 1 }









Tesink                      Standards Track                    [Page 47]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetVTCurrentStatus OBJECT-TYPE
       SYNTAX  Integer32 (1..126)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
         "This variable indicates the
         status of the interface.
         The sonetVTCurrentStatus
         is a bit map represented
         as a sum, therefore,
         it can represent multiple defects
         and failures
         simultaneously.
         The sonetVTNoDefect should be
         set if and only if
         no other flag is set.

         The various bit positions are:
            1   sonetVTNoDefect
            2   sonetVTLOP
            4   sonetVTPathAIS
            8   sonetVTPathRDI
           16   sonetVTPathRFI
           32   sonetVTUnequipped
           64   sonetVTSignalLabelMismatch"
   ::= { sonetVTCurrentEntry 2 }

   sonetVTCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Errored
        Seconds encountered by a SONET/SDH
        VT in the current 15 minute interval."
   ::= { sonetVTCurrentEntry 3 }

   sonetVTCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH VT in the current 15 minute
        interval."
   ::= { sonetVTCurrentEntry 4 }




Tesink                      Standards Track                    [Page 48]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetVTCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH VT in the current 15 minute interval."
   ::= { sonetVTCurrentEntry 5 }

   sonetVTCurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a VT in the current
        15 minute interval."
   ::= { sonetVTCurrentEntry 6 }

   -- the SONET/SDH VT Interval Table

   -- The SONET/SDH VT Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetVTIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH VT Interval table."
   ::= { sonetVT 2 }

   sonetVTIntervalEntry OBJECT-TYPE
       SYNTAX  SonetVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH VT Interval table."
       INDEX   { ifIndex,



Tesink                      Standards Track                    [Page 49]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                 sonetVTIntervalNumber }
   ::= { sonetVTIntervalTable 1 }

   SonetVTIntervalEntry ::=
       SEQUENCE {
           sonetVTIntervalNumber     Integer32,
           sonetVTIntervalESs        PerfIntervalCount,
           sonetVTIntervalSESs       PerfIntervalCount,
           sonetVTIntervalCVs        PerfIntervalCount,
           sonetVTIntervalUASs       PerfIntervalCount,
           sonetVTIntervalValidData  TruthValue
       }

   sonetVTIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "A number between 1 and 96, which identifies the
         interval for which the set of statistics is available.
         The interval identified by 1 is the most recently
         completed 15 minute interval,
         and the interval identified
         by N is the interval immediately preceding the
         one identified
         by N-1."
   ::= { sonetVTIntervalEntry 1 }

   sonetVTIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Errored Seconds encountered
        by a SONET/SDH VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 2 }

   sonetVTIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH VT
        in a particular 15-minute interval



Tesink                      Standards Track                    [Page 50]
^L
RFC 3592                   SONET/SDH Objects              September 2003


        in the past 24 hours."
   ::= { sonetVTIntervalEntry 3 }

   sonetVTIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 4 }

   sonetVTIntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 5 }

   sonetVTIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetVTIntervalEntry 6 }

   -- The SONET/SDH Far End VT group

   -- This group consists of two tables:
   --    SONET/SDH Far End VT Current Table
   --    SONET/SDH Far End VT Interval Table

   -- The SONET/SDH Far End VT Current

   -- The SONET/SDH Far End VT Current table
   -- contains various statistics
   -- being collected for the current 15 minute interval.
   -- The statistics are collected from
   -- the far end block error code
   -- (FEBE) within the G1 byte of the VT Overhead.



Tesink                      Standards Track                    [Page 51]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   -- The definitions are the same as described for
   -- the near-end information.

   sonetFarEndVTCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "The SONET/SDH Far End VT Current table."
       ::= { sonetFarEndVT 1 }

   sonetFarEndVTCurrentEntry OBJECT-TYPE
       SYNTAX  SonetFarEndVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "An entry in the SONET/SDH Far End VT Current table."
       INDEX   { ifIndex }
       ::= { sonetFarEndVTCurrentTable 1 }

   SonetFarEndVTCurrentEntry ::=
       SEQUENCE {
           sonetFarEndVTCurrentESs       PerfCurrentCount,
           sonetFarEndVTCurrentSESs      PerfCurrentCount,
           sonetFarEndVTCurrentCVs       PerfCurrentCount,
           sonetFarEndVTCurrentUASs      PerfCurrentCount
       }

   sonetFarEndVTCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of Far
           End Errored Seconds encountered by a SONET/SDH
           interface in the current 15 minute interval."
   ::= { sonetFarEndVTCurrentEntry 1 }

   sonetFarEndVTCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of
           Far End Severely Errored Seconds
           encountered by a SONET/SDH VT interface
           in the current 15 minute
           interval."



Tesink                      Standards Track                    [Page 52]
^L
RFC 3592                   SONET/SDH Objects              September 2003


       ::= { sonetFarEndVTCurrentEntry 2 }

   sonetFarEndVTCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of
           Far End Coding Violations reported via
           the far end block error count
           encountered by a
           SONET/SDH VT interface
           in the current 15 minute interval."
       ::= { sonetFarEndVTCurrentEntry 3 }

   sonetFarEndVTCurrentUASs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
         "The counter associated with the number of
         Far End Unavailable Seconds
         encountered by a
         SONET/SDH VT interface
         in the current 15 minute interval."
      ::= { sonetFarEndVTCurrentEntry 4 }

   -- The SONET/SDH Far End VT Interval Table

   -- The SONET/SDH Far End VT Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetFarEndVTIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Far End VT Interval table."
       ::= { sonetFarEndVT 2 }





Tesink                      Standards Track                    [Page 53]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetFarEndVTIntervalEntry OBJECT-TYPE
       SYNTAX  SonetFarEndVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "An entry in the SONET/SDH Far
         End VT Interval table."
       INDEX   { ifIndex,
                 sonetFarEndVTIntervalNumber }
       ::= { sonetFarEndVTIntervalTable 1 }

   SonetFarEndVTIntervalEntry ::=
      SEQUENCE {
            sonetFarEndVTIntervalNumber     Integer32,
            sonetFarEndVTIntervalESs        PerfIntervalCount,
            sonetFarEndVTIntervalSESs       PerfIntervalCount,
            sonetFarEndVTIntervalCVs        PerfIntervalCount,
            sonetFarEndVTIntervalUASs       PerfIntervalCount,
            sonetFarEndVTIntervalValidData  TruthValue
       }

   sonetFarEndVTIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "A number between 1 and 96, which identifies the
          interval for which the set of statistics is available.
          The interval identified by 1 is the most recently
          completed 15 minute interval,
          and the interval identified
          by N is the interval immediately preceding the
          one identified
          by N-1."
       ::= { sonetFarEndVTIntervalEntry 1 }

   sonetFarEndVTIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
             "The counter associated with the number of
             Far End Errored Seconds encountered
             by a SONET/SDH VT interface
             in a particular 15-minute interval
             in the past 24 hours."
      ::= { sonetFarEndVTIntervalEntry 2 }




Tesink                      Standards Track                    [Page 54]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   sonetFarEndVTIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
             "The counter associated with the number of
             Far End Severely Errored Seconds
             encountered by a SONET/SDH VT interface
             in a particular 15-minute interval
             in the past 24 hours."
       ::= { sonetFarEndVTIntervalEntry 3 }

   sonetFarEndVTIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH VT interface in a
            particular 15-minute interval
            in the past 24 hours."
       ::= { sonetFarEndVTIntervalEntry 4 }

   sonetFarEndVTIntervalUASs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH VT interface in a
          particular 15-minute interval
          in the past 24 hours."
      ::= { sonetFarEndVTIntervalEntry 5 }

   sonetFarEndVTIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetFarEndVTIntervalEntry 6 }




Tesink                      Standards Track                    [Page 55]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   -- conformance information

   sonetConformance OBJECT IDENTIFIER ::= { sonetMIB 4 }

   sonetGroups      OBJECT IDENTIFIER ::= { sonetConformance 1 }
   sonetCompliances OBJECT IDENTIFIER ::= { sonetConformance 2 }

   -- deprecated compliance statement

   sonetCompliance MODULE-COMPLIANCE
       STATUS  deprecated
       DESCRIPTION
               "The compliance statement for SONET/SDH interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { sonetMediumStuff, sonetSectionStuff }

           GROUP       sonetLineStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries."

           GROUP       sonetFarEndLineStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries, and that
                provide for a far end block error (FEBE)
                information at the SONET/SDH Line Layer."

           GROUP       sonetPathStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries."

           OBJECT      sonetPathCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndPathStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries, and that process
                Far End information."



Tesink                      Standards Track                    [Page 56]
^L
RFC 3592                   SONET/SDH Objects              September 2003


           GROUP       sonetVTStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH Virtual
                Tributaries."

           OBJECT      sonetVTCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndVTStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate the SONET/SDH
                floating Virtual Tributaries, and that process
                Far End information."

       ::= { sonetCompliances 1 }

   -- current compliance statements

   sonetCompliance2 MODULE-COMPLIANCE
       STATUS  current
       DESCRIPTION
               "The compliance statement for SONET/SDH interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { sonetMediumStuff2, sonetSectionStuff2 }

           OBJECT      sonetMediumType
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      sonetMediumLineCoding
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      sonetMediumLineType
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      sonetMediumCircuitIdentifier
           MIN-ACCESS  read-only
           DESCRIPTION



Tesink                      Standards Track                    [Page 57]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               "Write access is not required."

           OBJECT      sonetMediumLoopbackConfig
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      sonetSESthresholdSet
           MIN-ACCESS  read-only
           DESCRIPTION
             "Write access is not required, and only one
             of the enumerated values need be supported."

           GROUP       sonetLineStuff2
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries."

           GROUP       sonetFarEndLineStuff2
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries, and that
                provide for a far end block error (FEBE)
                information at the SONET/SDH Line Layer."

           GROUP       sonetPathStuff2
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries."

           OBJECT      sonetPathCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndPathStuff2
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries, and that process
                Far End information."

           GROUP       sonetVTStuff2
           DESCRIPTION
               "Implementation of this group is mandatory for all



Tesink                      Standards Track                    [Page 58]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                SONET/SDH systems that terminate SONET/SDH Virtual
                Tributaries."

           OBJECT      sonetVTCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndVTStuff2
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate the SONET/SDH
                floating Virtual Tributaries, and that process
                Far End information."

       ::= { sonetCompliances 2 }

   -- units of conformance

   -- deprecated groups

   sonetMediumStuff    OBJECT-GROUP
       OBJECTS { sonetMediumType,
                 sonetMediumTimeElapsed,
                 sonetMediumValidIntervals,
                 sonetMediumLineCoding,
                 sonetMediumLineType,
                 sonetMediumCircuitIdentifier }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing configuration
               information applicable to all SONET/SDH interfaces."
       ::= { sonetGroups 1 }

   sonetSectionStuff    OBJECT-GROUP
       OBJECTS { sonetSectionCurrentStatus,
                 sonetSectionCurrentESs,
                 sonetSectionCurrentSESs,
                 sonetSectionCurrentSEFSs,
                 sonetSectionCurrentCVs,
                 sonetSectionIntervalESs,
                 sonetSectionIntervalSESs,
                 sonetSectionIntervalSEFSs,
                 sonetSectionIntervalCVs
    }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing information



Tesink                      Standards Track                    [Page 59]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               specific to SONET/SDH Section interfaces."
       ::= { sonetGroups 2 }

   sonetLineStuff    OBJECT-GROUP
       OBJECTS { sonetLineCurrentStatus,
                 sonetLineCurrentESs,
                 sonetLineCurrentSESs,
                 sonetLineCurrentCVs,
                 sonetLineCurrentUASs,
                 sonetLineIntervalESs,
                 sonetLineIntervalSESs,
                 sonetLineIntervalCVs,
                 sonetLineIntervalUASs }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Line interfaces."
       ::= { sonetGroups 3 }

   sonetFarEndLineStuff    OBJECT-GROUP
       OBJECTS { sonetFarEndLineCurrentESs,
                 sonetFarEndLineCurrentSESs,
                 sonetFarEndLineCurrentCVs,
                 sonetFarEndLineCurrentUASs,
                 sonetFarEndLineIntervalESs,
                 sonetFarEndLineIntervalSESs,
                 sonetFarEndLineIntervalCVs,
                 sonetFarEndLineIntervalUASs }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Line interfaces,
               and maintaining Line Far End information."
       ::= { sonetGroups 4 }

   sonetPathStuff    OBJECT-GROUP
       OBJECTS { sonetPathCurrentWidth,
                 sonetPathCurrentStatus,
                 sonetPathCurrentESs,
                 sonetPathCurrentSESs,
                 sonetPathCurrentCVs,
                 sonetPathCurrentUASs,
                 sonetPathIntervalESs,
                 sonetPathIntervalSESs,
                 sonetPathIntervalCVs,
                 sonetPathIntervalUASs }
       STATUS  deprecated
       DESCRIPTION



Tesink                      Standards Track                    [Page 60]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               "A collection of objects providing information
               specific to SONET/SDH Path interfaces."
       ::= { sonetGroups 5 }

   sonetFarEndPathStuff    OBJECT-GROUP
       OBJECTS { sonetFarEndPathCurrentESs,
                 sonetFarEndPathCurrentSESs,
                 sonetFarEndPathCurrentCVs,
                 sonetFarEndPathCurrentUASs,
                 sonetFarEndPathIntervalESs,
                 sonetFarEndPathIntervalSESs,
                 sonetFarEndPathIntervalCVs,
                 sonetFarEndPathIntervalUASs }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Path interfaces,
               and maintaining Path Far End information."
       ::= { sonetGroups 6 }

   sonetVTStuff    OBJECT-GROUP
       OBJECTS { sonetVTCurrentWidth,
                 sonetVTCurrentStatus,
                 sonetVTCurrentESs,
                 sonetVTCurrentSESs,
                 sonetVTCurrentCVs,
                 sonetVTCurrentUASs,
                 sonetVTIntervalESs,
                 sonetVTIntervalSESs,
                 sonetVTIntervalCVs,
                 sonetVTIntervalUASs }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH VT interfaces."
       ::= { sonetGroups 7 }

   sonetFarEndVTStuff    OBJECT-GROUP
       OBJECTS { sonetFarEndVTCurrentESs,
                 sonetFarEndVTCurrentSESs,
                 sonetFarEndVTCurrentCVs,
                 sonetFarEndVTCurrentUASs,
                 sonetFarEndVTIntervalESs,
                 sonetFarEndVTIntervalSESs,
                 sonetFarEndVTIntervalCVs,
                 sonetFarEndVTIntervalUASs }
       STATUS  deprecated
       DESCRIPTION



Tesink                      Standards Track                    [Page 61]
^L
RFC 3592                   SONET/SDH Objects              September 2003


               "A collection of objects providing information
               specific to SONET/SDH VT interfaces,
               and maintaining VT Far End information."
       ::= { sonetGroups 8 }

   -- current groups

   sonetMediumStuff2    OBJECT-GROUP
       OBJECTS { sonetMediumType,
                 sonetMediumTimeElapsed,
                 sonetMediumValidIntervals,
                 sonetMediumLineCoding,
                 sonetMediumLineType,
                 sonetMediumCircuitIdentifier,
                 sonetMediumInvalidIntervals,
                 sonetMediumLoopbackConfig,
                 sonetSESthresholdSet }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing configuration
               information applicable to all SONET/SDH interfaces."
       ::= { sonetGroups 9 }

   sonetSectionStuff2    OBJECT-GROUP
       OBJECTS { sonetSectionCurrentStatus,
                 sonetSectionCurrentESs,
                 sonetSectionCurrentSESs,
                 sonetSectionCurrentSEFSs,
                 sonetSectionCurrentCVs,
                 sonetSectionIntervalESs,
                 sonetSectionIntervalSESs,
                 sonetSectionIntervalSEFSs,
                 sonetSectionIntervalCVs,
                 sonetSectionIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Section interfaces."
       ::= { sonetGroups 10 }

   sonetLineStuff2    OBJECT-GROUP
       OBJECTS { sonetLineCurrentStatus,
                 sonetLineCurrentESs,
                 sonetLineCurrentSESs,
                 sonetLineCurrentCVs,
                 sonetLineCurrentUASs,
                 sonetLineIntervalESs,
                 sonetLineIntervalSESs,



Tesink                      Standards Track                    [Page 62]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                 sonetLineIntervalCVs,
                 sonetLineIntervalUASs,
                 sonetLineIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Line interfaces."
       ::= { sonetGroups 11 }

   sonetPathStuff2    OBJECT-GROUP
       OBJECTS { sonetPathCurrentWidth,
                 sonetPathCurrentStatus,
                 sonetPathCurrentESs,
                 sonetPathCurrentSESs,
                 sonetPathCurrentCVs,
                 sonetPathCurrentUASs,
                 sonetPathIntervalESs,
                 sonetPathIntervalSESs,
                 sonetPathIntervalCVs,
                 sonetPathIntervalUASs,
                 sonetPathIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Path interfaces."
       ::= { sonetGroups 12 }

   sonetVTStuff2    OBJECT-GROUP
       OBJECTS { sonetVTCurrentWidth,
                 sonetVTCurrentStatus,
                 sonetVTCurrentESs,
                 sonetVTCurrentSESs,
                 sonetVTCurrentCVs,
                 sonetVTCurrentUASs,
                 sonetVTIntervalESs,
                 sonetVTIntervalSESs,
                 sonetVTIntervalCVs,
                 sonetVTIntervalUASs,
                 sonetVTIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH VT interfaces."
       ::= { sonetGroups 13 }

   sonetFarEndLineStuff2    OBJECT-GROUP
       OBJECTS { sonetFarEndLineCurrentESs,
                 sonetFarEndLineCurrentSESs,



Tesink                      Standards Track                    [Page 63]
^L
RFC 3592                   SONET/SDH Objects              September 2003


                 sonetFarEndLineCurrentCVs,
                 sonetFarEndLineCurrentUASs,
                 sonetFarEndLineIntervalESs,
                 sonetFarEndLineIntervalSESs,
                 sonetFarEndLineIntervalCVs,
                 sonetFarEndLineIntervalUASs,
                 sonetFarEndLineIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Line interfaces,
               and maintaining Line Far End information."
       ::= { sonetGroups 14 }

   sonetFarEndPathStuff2    OBJECT-GROUP
       OBJECTS { sonetFarEndPathCurrentESs,
                 sonetFarEndPathCurrentSESs,
                 sonetFarEndPathCurrentCVs,
                 sonetFarEndPathCurrentUASs,
                 sonetFarEndPathIntervalESs,
                 sonetFarEndPathIntervalSESs,
                 sonetFarEndPathIntervalCVs,
                 sonetFarEndPathIntervalUASs,
                 sonetFarEndPathIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH Path interfaces,
               and maintaining Path Far End information."
       ::= { sonetGroups 15 }

   sonetFarEndVTStuff2    OBJECT-GROUP
       OBJECTS { sonetFarEndVTCurrentESs,
                 sonetFarEndVTCurrentSESs,
                 sonetFarEndVTCurrentCVs,
                 sonetFarEndVTCurrentUASs,
                 sonetFarEndVTIntervalESs,
                 sonetFarEndVTIntervalSESs,
                 sonetFarEndVTIntervalCVs,
                 sonetFarEndVTIntervalUASs,
                 sonetFarEndVTIntervalValidData }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to SONET/SDH VT interfaces,
               and maintaining VT Far End information."
       ::= { sonetGroups 16 }




Tesink                      Standards Track                    [Page 64]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   END

5.  Acknowledgments

   This specification is a product of the AToM MIB Working Group.  The
   author would like to acknowledge Mike Heard for his many valuable
   contributions to this memo.

6.  Security Considerations

   There are a number of management objects defined in this MIB module
   that have a MAX-ACCESS clause of read-write:  sonetMediumType,
   sonetMediumLineCoding, sonetMediumLineType,
   sonetMediumCircuitIdentifier, sonetMediumLoopbackConfig,
   sonetSESthresholdSet, sonetPathCurrentWidth, and sonetVTCurrentWidth.
   It is possible for writes to these objects to have disruptive effects
   on network operation that range from invalid performance data to
   traffic interruptions.  Users of this MIB module must therefore be
   aware that support for SET operations in a non-secure environment
   without proper protection can have a negative effect on network
   operations.

   The readable objects in this MIB module (i.e., the objects with a
   MAX-ACCESS other than not-accessible) may be considered sensitive in
   some environments since, collectively, they provide extensive
   information about the performance of interfaces in SONET/SDH
   equipment or networks and can reveal some aspects of their
   configuration.  In such environments it is important to control even
   GET and NOTIFY access to these objects and possibly to encrypt the
   values of these objects when sending them over the network via SNMP.

   SNMP versions prior to SNMPv3 did not include adequate security.
   Even if the network itself is secure (for example by using IPSec),
   even then, there is no control as to who on the secure network is
   allowed to access and GET/SET (read/change/create/delete) the objects
   in this MIB module.

   It is RECOMMENDED that implementers consider the security features as
   provided by the SNMPv3 framework (see [RFC3410], section 8),
   including full support for the SNMPv3 cryptographic mechanisms (for
   authentication and privacy).

   Further, deployment of SNMP versions prior to SNMPv3 is NOT
   RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
   enable cryptographic security.  It is then a customer/operator
   responsibility to ensure that the SNMP entity giving access to an





Tesink                      Standards Track                    [Page 65]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   instance of this MIB module is properly configured to give access to
   the objects only to those principals (users) that have legitimate
   rights to indeed GET or SET (change/create/delete) them.

7.  References

7.1.  Normative References

   [RFC2119]    Bradner, S., "Key words for use in RFCs to Indicate
                Requirements Levels", BCP 14, RFC 2119, March 1997.

   [RFC2578]    McCloghrie, K., Perkins, D. and J. Schoenwaelder,
                "Structure of Management Information Version 2 (SMIv2)",
                STD 58, RFC 2578, April 1999.

   [RFC2579]    McCloghrie, K., Perkins, D. and J. Schoenwaelder,
                "Textual Conventions for SMIv2", STD 58, RFC 2579, April
                1999.

   [RFC2580]    McCloghrie, K., Perkins, D. and J. Schoenwaelder,
                "Conformance Statements for SMIv2", STD 58, RFC 2580,
                April 1999.

   [RFC3593]    Tesink, K., "Textual Conventions for MIB Modules Using
                Performance History Based on 15 Minute Intervals", RFC
                3593, September 2003.

   [T1.105a]    American National Standard for Telecommunications -
                Digital Hierarchy - Optical Interface Rates and Formats
                Specification, ANSI T1.105-1988.

   [T1.105b]    American National Standard for Telecommunications -
                Digital Hierarchy - Optical Interface Rates and Formats
                Specification, ANSI T1.105-1991.

   [T1.106]     American National Standard for Telecommunications -
                Digital Hierarchy - Optical Interface Specification
                (Single-Mode), ANSI T1.106-1988.

   [T1M1.3]     Draft American National Standard for Telecommunications
                - Digital Hierarchy - Layer 1 In-Service Digital
                Transmission Performance Monitoring, T1M1.3/93-005R2,
                July 1993.

   [G.707]      CCITT Recommendation G.707, "Synchronous Digital
                Hierarchy Bit Rates", June 1992.





Tesink                      Standards Track                    [Page 66]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   [G.708]      CCITT Recommendation G.708, "Network Node Interface for
                the Synchronous Digital Hierarchy", June 1992.

   [G.709]      CCITT Recommendation G.709, "Synchronous Multiplexing
                Structure", June 1992.

   [G.783]      CCITT Recommendation G.783, "Characteristics of
                Synchronous Digital Hierarchy (SDH) Multiplexing
                Equipment Functional Blocks", November 1992.

   [RFC1213]    McCloghrie, K. and M. Rose, "Management Information Base
                for Network Management of TCP/IP-based internets: MIB-
                II", RFC 1213, March 1991.

   [RFC2863]    McCloghrie, K. and F. Kastenholz, "The Interfaces Group
                MIB", RFC 2863, June 2000.

   [RFC2864]    McCloghrie, K. and G. Hanson, "The Inverted Stack Table
                Extension to the Interfaces Group MIB", RFC 2864, June
                2000.

   [T1.231a]    American National Standard for Telecommunications -
                Digital Hierarchy - Layer 1 In-Service Digital
                Transmission Performance Monitoring, ANSI T1.231-1993,
                September 1993.

   [TR253]      Bellcore TR-NWT-000253, Issue 1, "Synchronous Optical
                Network (SONET) Transport Systems:  Common Generic
                Criteria", December 1991.

   [G.826]      ITU Recommendation G.826, "Error Performance Parameters
                and Objectives for International Constant Bit Rate
                Digital Paths at or above Primary Rate", September 1995
                (COM 13-R57E).

   [GR253]      Bellcore GR-253-CORE, Issue 2, "Synchronous Optical
                Network (SONET) Transport Systems Common Generic
                Criteria", December 1995.

   [T1.231b]    American National Standard for Telecommunications -
                Digital Hierarchy - Layer 1 In-Service Digital
                Transmission Performance Monitoring, ANSI T1.231-1997,
                September 1997.








Tesink                      Standards Track                    [Page 67]
^L
RFC 3592                   SONET/SDH Objects              September 2003


7.2.  Informative References

   [RFC1595]    Brown, T. and K. Tesink, "Definitions of Managed Objects
                for the SONET/SDH Interface Type", RFC 1595, March 1994.

   [RFC2495]    Fowler, D., "Definitions of Managed Objects for the DS1,
                E1, DS2 and E2 Interface Types", RFC 2495, January 1999.

   [RFC2496]    Fowler, D., "Definitions of Managed Objects for the
                DS3/E3 Interface Type", RFC 2496, January 1999.

   [RFC2558]    Tesink, K., "Definitions of Managed Objects for the
                SONET/SDH Interface Type", RFC 2558, March 1999.

   [RFC3410]    Case, J., Mundy, R., Partain, D. and B. Stewart,
                "Introduction and Applicability Statements for Internet-
                Standard Management Framework", RFC 3410, December 2002.

8.  Intellectual Property Statement

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.












Tesink                      Standards Track                    [Page 68]
^L
RFC 3592                   SONET/SDH Objects              September 2003


Appendix A:  The delay-line approach to statistics collection.

   According to ANSI T1.231 unavailable time begins at the onset of 10
   contiguous severely errored seconds -- that is, unavailable time
   starts with the first of the 10 contiguous SESs -- and while an
   interface is deemed unavailable all counters for that interface are
   frozen except for the UAS count.  Since changes in the signal state
   lag the data to which they apply by 10 seconds, an implementation
   which wishes to avoid making retroactive adjustments to the counts
   must pass the the one-second statistics through a 10-second delay
   line prior to updating any counters.  That can be done by performing
   the following steps at the end of each one second interval.

   i)   Read near/far end line and path CV counts and alarm status flags
        from the hardware.

   ii)  Accumulate the CV counts for the preceding second and compare
        them to the ES and SES threshold for the layer in question.
        Update the signal state and shift the one-second CV counts and
        ES/SES flags into the 10-element delay line.  Note that far-end
        one-second statistics are to be flagged as "absent" during any
        second in which there is an incoming defect at the layer in
        question or at any lower layer.

   iii) Update the current interval statistics using the signal state
        from the previous update cycle and the one-second CV counts and
        ES/SES flags shifted out of the 10-element delay line.

   This procedure guarantees that the statistical counters will be
   correctly updated at all times, although they lag real time by 10
   seconds.  It is illustrated in the figure below.  At the end of each
   15 minutes interval the current interval counts are transferred to
   the  most recent interval entry and each interval is shifted up by
   one position, with the oldest being discarded if necessary in order
   to make room.  The current interval counts then start over from zero.
   Note, however, that the signal state calculation does not start anew
   at each interval boundary;  rather, signal state information is
   retained across interval boundaries.













Tesink                      Standards Track                    [Page 69]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   +--------------------------------------------------------------+
   |          READ COUNTERS & STATUS INFO FROM HARDWARE           |
   |                                                              |
   |LOS OOF/ SECT  LINE LINE LINE LINE  PATH PATH PATH PATH PATH  |
   |    LOF   CV    AIS  CV   RDI FEBE   AIS  LOP  CV   RDI  CV   |
   +--------------------------------------------------------------+
     |   |     |     |    |    |   |      |    |    |    |    |
     |   |     |     |    |    |   |      |    |    |    |    |
     V   V     V     V    V    V   V      V    V    V    V    V
   +--------------------------------------------------------------+
   | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE |
   |                                                              |
   |                                                              |
   |                  NEAR END/FAR END       NEAR END/FAR END     |
   |SECT SECT SECT  LINE LINE LINE  LINE   PATH PATH PATH  PATH   |
   |CV   ES   SES    CV   ES   SES AVA/UNA  CV   ES   SES AVA/UNA |
   +--------------------------------------------------------------+
     |    |    |      |    |    |     |      |    |    |     |
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     |      V    V    V     |
   +-------------+  +-------------+   |    +-------------+   |
   |ONE-SEC DELAY|  |ONE-SEC DELAY|   |    |ONE-SEC DELAY|   |
   | (1 OF 10)   |  | (1 OF 10)   |   |    | (1 OF 10)   |   |
   |CV   ES   SES|  |CV   ES   SES|   |    |CV   ES   SES|   |
   +-------------+  +-------------+   |    +-------------+   |
     |    |    |      |    |    |     |      |    |    |     |
     /    /    /      /    /    /     /      /    /    /     /
     /    /    /      /    /    /     /      /    /    /     /
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     |      V    V    V     |
   +-------------+  +-------------+   |    +-------------+   |
   |ONE-SEC DELAY|  |ONE-SEC DELAY|   |    |ONE-SEC DELAY|   |
   | (10 OF 10)  |  | (10 OF 10)  |   |    | (10 OF 10)  |   |
   |CV   ES   SES|  |CV   ES   SES|   |    |CV   ES   SES|   |
   +-------------+  +-------------+   |    +-------------+   |
     |    |    |      |    |    |     |      |    |    |     |
     |    |    |      |    |    |     |      |    |    |     |
     V    V    V      V    V    V     V      V    V    V     V
   +--------------------------------------------------------------+
   |              UPDATE STATISTICS COUNTERS                      |
   |                                                              |
   |                   NEAR END/FAR END       NEAR END/FAR END    |
   |   SECTION               LINE                   PATH          |
   | CV ES EFS SES   CV ES EFS SES AS UAS   CV ES EFS SES AS UAS  |
   +--------------------------------------------------------------+

   Note that if such a procedure is adopted there is no current interval
   data for the first ten seconds after a system comes up.



Tesink                      Standards Track                    [Page 70]
^L
RFC 3592                   SONET/SDH Objects              September 2003


   noSuchInstance must be returned if a management station attempts to
   access the current interval counters during this time.

   It is an implementation-specific matter whether an agent assumes that
   the initial state of the interface is available or unavailable.

Appendix B - RFC 1595 SES interpretation

   This appendix contains the values for x for the Section, Line, Path,
   and VT Layers as used in [T1M1.3][RFC1595][TR253].

        Value for x for SONET/SDH Section SES Definition

   Rate            x               Minimum Bit Error Rate
   =======================================================
   OC-1             9                      1.5 x 10^-7
   OC-3            16                        1 x 10^-7
   OC-9            47                        1 x 10^-7
   OC-12           63                        1 x 10^-7
   OC-18           94                        1 x 10^-7
   OC-24          125                        1 x 10^-7
   OC-36          187                        1 x 10^-7
   OC-48          249                        1 x 10^-7


        Value for x for SONET/SDH Line SES Definition

   Rate            x               Minimum Bit Error Rate
   =======================================================
   OC-1            12                       2 x 10^-7
   OC-3            32                       2 x 10^-7
   OC-9            47                       2 x 10^-7
   OC-12          124                       2 x 10^-7
   OC-18          186                       2 x 10^-7
   OC-24          248                       2 x 10^-7
   OC-36          370                       2 x 10^-7
   OC-48          494                       2 x 10^-7


        Value for x for SONET/SDH STS-Path SES Definition

   Rate            x               Minimum Bit Error Rate
   =======================================================
   STS-1            9                       1.5 x 10^-7
   STS-3           16                         1 x 10^-7






Tesink                      Standards Track                    [Page 71]
^L
RFC 3592                   SONET/SDH Objects              September 2003


        Value for x for SONET/SDH VT-Path SES Definition

   Rate            x               Minimum Bit Error Rate
   =======================================================
   VT1.5            4                       2 x 10^-6
   VT2              6                       2 x 10^-6
   VT3              8                       2 x 10^-6
   VT6             14                       2 x 10^-6

Author's Address

   Kaj Tesink
   Telcordia Technologies
   331 Newman Springs Road
   P.O. Box 7020
   Red Bank, NJ  07701-7020

   Phone: (732) 758-5254
   EMail: kaj@research.telcordia.com
































Tesink                      Standards Track                    [Page 72]
^L
RFC 3592                   SONET/SDH Objects              September 2003


Full Copyright Statement

   Copyright (C) The Internet Society (2003).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

   Funding for the RFC Editor function is currently provided by the
   Internet Society.



















Tesink                      Standards Track                    [Page 73]
^L