summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc4327.txt
blob: 21ea638a58f04c550ffdb101926f79b1c7b538ca (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
Network Working Group                                           M. Dubuc
Request for Comments: 4327                                     T. Nadeau
Category: Standards Track                                  Cisco Systems
                                                                 J. Lang
                                                             Sonos, Inc.
                                                             E. McGinnis
                                                      Hammerhead Systems
                                                            January 2006


    Link Management Protocol (LMP) Management Information Base (MIB)

Status of This Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2006).

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes managed objects for modeling the Link
   Management Protocol (LMP).

Table of Contents

   1. The Internet-Standard Management Framework ......................2
   2. Introduction ....................................................2
   3. Terminology .....................................................3
   4. Feature Checklist ...............................................3
   5. Outline .........................................................4
   6. Brief Description of MIB Objects ................................4
      6.1. lmpNbrTable ................................................4
      6.2. lmpControlChannelTable .....................................4
      6.3. lmpControlChannelPerfTable .................................4
      6.4. lmpTeLinkTable .............................................5
      6.5. lmpLinkVerificationTable ...................................5
      6.6. lmpTeLinkPerfTable .........................................5
      6.7. lmpDataLinkTable ...........................................5
      6.8. lmpDataLinkPerfTable .......................................5
   7. Example of LMP Control Channel Setup ............................5



Dubuc, et al.               Standards Track                     [Page 1]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   8. Application of the Interfaces Group to LMP ......................8
      8.1. Support of the LMP Layer by ifTable ........................9
   9. LMP MIB Module Definitions .....................................11
   10. Security Considerations .......................................77
   11. Contributors ..................................................78
   12. Acknowledgements ..............................................78
   13. IANA Considerations ...........................................78
      13.1. IANA Considerations for lmp ifType .......................78
      13.2. IANA Considerations for LMP-MIB ..........................78
   14. References ....................................................79
      14.1. Normative References .....................................79
      14.2. Informative References ...................................80

1.  The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
   [RFC2580].

2.  Introduction

   Current work is under way in the IETF to specify a suite of protocols
   to be used as a common control plane and a separate common
   measurement plane.  Generalized MPLS (GMPLS) [RFC3471] and the Link
   Management Protocol [RFC4204] are key components of this
   standardization activity.  The primary purpose of LMP is to manage
   traffic engineering (TE) links.  Primary goals of LMP are the
   maintenance of the control channel connectivity, correlation of link
   properties, verification of data-bearing links, and detection and
   isolation of link faults.

   We describe in this document a MIB module that can be used to manage
   LMP implementations.  This MIB module covers both configuration and
   performance monitoring aspects of LMP.

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].




Dubuc, et al.               Standards Track                     [Page 2]
^L
RFC 4327                     LMP-MIB Module                 January 2006


3.  Terminology

   This document uses terminology from the document describing the Link
   Management Protocol [RFC4204].  An "LMP adjacency" is formed between
   two nodes that support the same capabilities, and LMP messages are
   exchanged between the node pair over control channels that form this
   adjacency.  Several control channels can be active at the same time.
   With the exception of messages related to control channel management,
   anytime an LMP message needs to be transferred to a neighbor node, it
   can be sent on any of the active control channels.  The control
   channels can also be used to exchange MPLS control plane information
   or routing information.

   LMP is designed to support aggregation of one or more data-bearing
   links into a traffic-engineering (TE) link.  The data-bearing links
   can be either component links or ports depending on their
   multiplexing capability (see [RFC4204] for distinction between port
   and component link).

   Each TE link is associated with an LMP adjacency, and one or more
   control channels are used to exchange LMP messages for a particular
   adjacency.  In turn, control channels are used to manage the TE links
   associated with the LMP adjacency.

4.  Feature Checklist

   The Link Management Protocol MIB module (LMP-MIB) is designed to
   satisfy the following requirements and constraints:

   -  The MIB module supports the enabling and disabling of LMP
      capability on LMP-capable interfaces of a photonic switch, optical
      cross-connect, or router.

   -  The MIB module is used to provide information about LMP
      adjacencies.

   -  Support is provided for configuration of the keep alive and link
      verification parameters.

   -  The MIB module is used to express the mapping between local and
      remote TE links, as well as local and remote interface identifiers
      for port or component link.

   -  Performance counters are provided for measuring LMP performance on
      a per-control channel basis.  Performance counters are also
      provided for measuring LMP performance on the data-bearing links.





Dubuc, et al.               Standards Track                     [Page 3]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   Note that the LMP MIB module goes hand-in-hand with the TE Link
   (TE-LINK-STD-MIB) MIB module [RFC4220].  The TE link table, which is
   used to associate data-bearing links to TE links, is defined in the
   TE Link MIB.  The TE link table in the LMP MIB module contains TE
   link information specific to LMP.

5.  Outline

   Configuring LMP through an optical device involves the following
   steps:

   -  Enabling LMP on LMP-capable interfaces through control channel
      configuration.

   -  Optionally specifying link verification parameters.

   -  Configuring the data-bearing links and associating them to the
      appropriate TE link (this association is stored in the
      ifStackTable of the Interfaces Group MIB).

   TE links are managed by the control channels that run between the
   same pair of nodes (LMP adjacency).

6.  Brief Description of MIB Objects

   Sections 6.1-6.8 describe objects pertaining to LMP.  The MIB objects
   were derived from the LMP document [RFC4204].

6.1.  lmpNbrTable

   The remote node table is used to identify the pair of nodes that
   exchange LMP messages over control channels.

6.2.  lmpControlChannelTable

   The control channel table is used for enabling the LMP protocol on
   LMP-capable interfaces.  A photonic switch, optical cross-connect, or
   router creates an entry in this table for every LMP-capable interface
   in that device.

6.3.  lmpControlChannelPerfTable

   The control channel performance table is used for collecting LMP
   performance counts on a per-control channel basis.  Each entry in the
   lmpControlChannelTable has a corresponding entry in the
   lmpControlChannelPerfTable.





Dubuc, et al.               Standards Track                     [Page 4]
^L
RFC 4327                     LMP-MIB Module                 January 2006


6.4.  lmpTeLinkTable

   The TE link table is used for specifying LMP information associated
   with TE links.

6.5.  lmpLinkVerificationTable

   The link verification table is used for configuring the LMP link
   verification parameters of TE links.  For every TE link entry in the
   lmpTeLinkTable that supports the link verification procedure, there
   is a corresponding entry in the lmpLinkVerificationTable.

6.6.  lmpTeLinkPerfTable

   The TE link performance table is used for collecting LMP performance
   counts on a per-TE link basis.  Each entry in the lmpTeLinkTable has
   a corresponding entry in the lmpTeLinkPerfTable.

6.7.  lmpDataLinkTable

   The data-bearing link table is used to specify the data-bearing links
   that are associated with TE links.

6.8.  lmpDataLinkPerfTable

   The data-bearing link performance table is used for collecting LMP
   performance counts on data-bearing links.

7.  Example of LMP Control Channel Setup

   In this section, we provide a brief example of using the MIB
   objects described in section 9 to set up an LMP control channel.
   While this example is not meant to illustrate every nuance of the
   MIB module, it is intended as an aid to understanding some of the
   key concepts.  It is meant to be read after going through the MIB
   itself.

   Suppose that one would like to form an LMP adjacency between two
   nodes using two control channels.  Suppose also that there are
   three data-bearing links.  We also assume that the data-bearing
   links are ports (lambdas).  We also assume that the link
   verification procedure is not enabled.  The following example
   illustrates which rows and corresponding objects might be created
   to accomplish this.

   First, LMP must be enabled between the pair of nodes.





Dubuc, et al.               Standards Track                     [Page 5]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   In lmpNbrTable:
   {
      lmpNbrNodeId                       = 'c0000201'H, -- 192.0.2.1
      lmpNbrAdminStatus                  = up(1),
      lmpNbrRowStatus                    = createAndGo(4),
      lmpNbrStorageType                  = nonVolatile(3)
   }

   Then, the control channels must be set up.  These are created in
   the lmpControlChannelTable.

   In lmpControlChannelTable:
   {
      lmpCcId                           = 1,
      lmpCcUnderlyingIfIndex            = 1,
      lmpCcIsIf                         = false(1),
      lmpCcAuthentication               = false(1),
      lmpCcHelloInterval                = 15,
      lmpCcHelloIntervalMin             = 15,
      lmpCcHelloIntervalMax             = 1000,
      lmpCcHelloDeadInterval            = 45,
      lmpCcHelloDeadIntervalMin         = 45,
      lmpCcHelloDeadIntervalMax         = 1000,
      lmpCcAdminStatus                  = up(1),
      lmpCcRowStatus                    = createAndGo(4),
      lmpCcStorageType                  = nonVolatile(3)
   }

   {
      lmpCcId                           = 2,
      lmpCcUnderlyingIfIndex            = 2,
      lmpCcIsIf                         = false(1),
      lmpCcAuthentication               = false(1),
      lmpCcHelloInterval                = 15,
      lmpCcHelloIntervalMin             = 15,
      lmpCcHelloIntervalMax             = 1000,
      lmpCcHelloDeadInterval            = 45,
      lmpCcHelloDeadIntervalMin         = 45,
      lmpCcHelloDeadIntervalMax         = 1000,
      lmpCcAdminStatus                  = up(1),
      lmpCcRowStatus                    = createAndGo(4),
      lmpCcStorageType                  = nonVolatile(3)
   }

   Next, the three data-bearing links are created.  For each data-
   bearing link, an ifEntry with the same ifIndex needs to be created
   beforehand.




Dubuc, et al.               Standards Track                     [Page 6]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   In lmpDataLinkTable:
   {
      ifIndex                         = 41,
      lmpDataLinkAddressType          = unknown(0),
      lmpDataLinkIpAddr               = ''H,
      lmpDataLinkRemoteIpAddress      = ''H,
      lmpDataLinkRemoteIfId           = 47,
      lmpDataLinkRowStatus            = createAndGo(4),
      lmpDataLinkStorageType          = nonVolatile(3)
   }

   {
      ifIndex                         = 43,
      lmpDataLinkAddressType          = unknown(0),
      lmpDataLinkIpAddr               = ''H,
      lmpDataLinkRemoteIpAddress      = ''H,
      lmpDataLinkRemoteIfId           = 42,
      lmpDataLinkRowStatus            = createAndGo(4),
      lmpDataLinkStorageType          = nonVolatile(3)
   }

   {
      ifIndex                         = 44,
      lmpDataLinkAddressType          = unknown(0),
      lmpDataLinkIpAddr               = ''H,
      lmpDataLinkRemoteIpAddress      = ''H,
      lmpDataLinkRemoteIfId           = 48,
      lmpDataLinkRowStatus            = createAndGo(4),
      lmpDataLinkStorageType          = nonVolatile(3)
   }

   Note that the data-bearing link type (lmpDataLinkType) does
   not need to be provisioned as it is automatically populated by the
   node.  The definition of the protection role (primary or
   secondary) for the data-bearing links is stored in the
   componentLinkTable of the TE Link MIB module [RFC4220].

   Then, a TE link is created as an ifEntry with ifType teLink in
   the ifTable.

   Once the TE link is created in the ifTable, a TE link entry
   is created in the LMP MIB module to specify TE link information
   specific to LMP.

   In lmpTeLinkTable:
   {
      ifIndex                     = 20,
      lmpTeLinkVerification       = true(2),



Dubuc, et al.               Standards Track                     [Page 7]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      lmpTeLinkFaultManagement    = true(2),
      lmpTeLinkDwdm               = false(1),
      lmpTeLinkRowStatus          = createAndGo(4),
      lmpTeLinkStorageType        = nonVolatile(3)
   }

   and in lmpLinkVerificationTable:
   {
      ifIndex                         = 20,
      lmpLinkVerifyInterval           = 100,
      lmpLinkVerifyDeadInterval       = 300,
      lmpLinkVerifyTransportMechanism = j0Trace(3),
      lmpLinkVerifyAllLinks           = true(2),
      lmpLinkVerifyTransmissionRate   = 100000,
      lmpLinkVerifyWavelength         = 0,
      lmpLinkVerifyRowStatus          = createAndGo(4),
      lmpLinkVerifyStorageType        = nonVolatile(3)
   }

   The association between the data-bearing links and the TE links is
   stored in the ifStackTable [RFC2863].

   In parallel with the entry created in the lmpTeLinkTable, an entry
   may be created in the teLinkTable of TE Link MIB module
   [RFC4220].

8.  Application of the Interfaces Group to LMP

   The Interfaces Group [RFC2863] defines generic managed objects for
   managing interfaces.  This memo contains the media-specific
   extensions to the Interfaces Group for managing LMP control channels
   that are modeled as interfaces.  If the control channel as defined in
   the lmpControlChannelTable is modeled as an ifEntry, then the
   following definition applies.  An lmpControlChannelTable entry is
   designated as being represented as an Interfaces MIB ifEntry if the
   lmpControlChannelEntry object lmpCcIsIf is set to true (2).  In this
   case, the control channel SHOULD be modeled as an ifEntry and
   provide appropriate interface stacking as defined below.

   This memo assumes the interpretation of the Interfaces Group to be
   in accordance with [RFC2863], which states that the interfaces table
   (ifTable) contains information on the managed resource's
   interfaces and that each sub-layer below the internetwork layer of
   a network interface is considered an interface.  Since the LMP
   interface only carries control traffic, it is considered to be below
   the internetwork layer.  Thus, the LMP interface may be represented
   as an entry in the ifTable.  The interrelation of entries in the
   ifTable is defined by Interfaces Stack Group defined in [RFC2863].



Dubuc, et al.               Standards Track                     [Page 8]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   When LMP control channels are modeled as interfaces, the interface
   stack table must appear as follows for the LMP control channel
   interfaces:

   +----------------------------------------+
   | LMP-interface ifType = lmp(227)        +
   +----------------------------------------+
   | Underlying Layer...                    +
   +----------------------------------------+

   In the above diagram, "Underlying Layer..." refers to the ifIndex
   of any interface type over which the LMP interface will transmit
   its traffic.  Note that if the underlying layer provides multiple
   access to its media (i.e., Ethernet), then it is possible to stack
   multiple LMP interfaces on top of this interface in parallel.

   Note that it is not a requirement that LMP control channels be
   modeled as interfaces.  It is acceptable that control channels
   simply exist as logical connections between adjacent LMP-capable
   nodes.  In this case, lmpCcIsIf is set to false(2) and no
   corresponding entry is made in the ifTable.

8.1.  Support of the LMP Layer by ifTable

   Some specific interpretations of ifTable for the LMP layer
   follow.

   Object        Use for the LMP layer.

   ifIndex       Each LMP interface may be represented by an ifEntry.

   ifDescr       Description of the LMP interface.

   ifType        The value that is allocated for LMP is 227.
                 This number has been assigned by the IANA.

   ifSpeed       The total bandwidth in bits per second for use by
                 the LMP layer.

   ifPhysAddress Unused.

   ifAdminStatus This variable indicates the administrator's intent
                 as to whether LMP should be enabled, disabled, or
                 running in some diagnostic testing mode on this
                 interface.  Also see [RFC2863].

   ifOperStatus  This value reflects the actual or operational
                 status of LMP on this interface.



Dubuc, et al.               Standards Track                     [Page 9]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   ifLastChange  See [RFC2863].

   ifInOctets    The number of received octets over the interface,
                 i.e., the number of octets received as LMP
                 packets.

   ifOutOctets   The number of transmitted octets over the
                 interface, i.e., the number of octets transmitted
                 as LMP packets.

   ifInErrors    The number of LMP packets dropped due to
                 uncorrectable errors.

   ifInUnknownProtos
                 The number of received packets discarded during
                 packet header validation, including packets with
                 unrecognized label values.

   ifOutErrors   See [RFC2863].

   ifName        Textual name (unique on this system) of the
                 interface or an octet string of zero length.

   ifLinkUpDownTrapEnable
                 Default is disabled (2).

   ifConnectorPresent
                 Set to false (2).

   ifHighSpeed   See [RFC2863].

   ifHCInOctets  The 64-bit version of ifInOctets; supported if
                 required by the compliance statements in [RFC2863].

   ifHCOutOctets The 64-bit version of ifOutOctets; supported if
                 required by the compliance statements in [RFC2863].

   ifAlias       The nonvolatile 'alias' name for the interface as
                 specified by a network manager.

   ifCounterDiscontinuityTime
                 See [RFC2863].









Dubuc, et al.               Standards Track                    [Page 10]
^L
RFC 4327                     LMP-MIB Module                 January 2006


9.  LMP MIB Module Definitions

   This MIB module IMPORTs objects from [RFC2578], [RFC2579], [RFC2580],
   [RFC2863], [RFC4001], and [RFC4220], and it has REFERENCE clauses to
   [RFC4204], [RFC4207], [RFC4209], [RFC3471], and [RFC2914].

LMP-MIB DEFINITIONS ::= BEGIN

IMPORTS
   MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
   transmission, Unsigned32, Counter32, TimeTicks
      FROM SNMPv2-SMI              -- [RFC2578]

   MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
      FROM SNMPv2-CONF             -- [RFC2580]

   TEXTUAL-CONVENTION, TruthValue, RowStatus, StorageType,
   TimeStamp
      FROM SNMPv2-TC               -- [RFC2579]

   InterfaceIndexOrZero, ifIndex
      FROM IF-MIB                  -- [RFC2863]

   InetAddressType, InetAddress
      FROM INET-ADDRESS-MIB        -- [RFC4001]

   teLinkRemoteIpAddr, teLinkIncomingIfId, TeLinkEncodingType
      FROM TE-LINK-STD-MIB;        -- [RFC4220]

lmpMIB MODULE-IDENTITY
   LAST-UPDATED "200601110000Z"  -- 11 January 2006
   ORGANIZATION "Common Control and Measurement Protocols (CCAMP)
                 Working Group"
   CONTACT-INFO
       "        Martin Dubuc
        Email:  dubuc.consulting@sympatico.ca

                Thomas D. Nadeau
        Email:  tnadeau@cisco.com

                Jonathan P. Lang
        Email:  jplang@ieee.org

                Evan McGinnis
        Email:  emcginnis@hammerheadsystems.com"


   DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 11]
^L
RFC 4327                     LMP-MIB Module                 January 2006


       "Copyright (C) 2006 The Internet Society.  This version of
        the MIB module is part of RFC 4327; see the RFC itself
        for full legal notices.

        This MIB module contains managed object definitions for
        the Link Management Protocol (LMP) as
        defined in 'Link Management Protocol'."

   -- Revision history.
   REVISION
       "200601110000Z"  -- 11 January 2006
   DESCRIPTION
       "Initial version published as RFC 4327"
   ::= { transmission 227 }

-- Textual Conventions

LmpInterval ::= TEXTUAL-CONVENTION
   DISPLAY-HINT "d"
   STATUS        current
   DESCRIPTION
       "The interval delay in milliseconds."
   SYNTAX        Unsigned32 (1..65535)

LmpRetransmitInterval ::= TEXTUAL-CONVENTION
   DISPLAY-HINT "d"
   STATUS        current
   DESCRIPTION
       "The retransmission interval delay in milliseconds."
   SYNTAX        Unsigned32 (1..4294967295)

LmpNodeId ::= TEXTUAL-CONVENTION
   DISPLAY-HINT  "1d.1d.1d.1d"
   STATUS        current
   DESCRIPTION
       "Represents a Node ID in network byte order.  Node ID is an
        address of type IPv4."
   REFERENCE
       "Section 1.1 of Link Management Protocol, RFC 4204"
   SYNTAX        OCTET STRING(SIZE(4))


-- Top level components of this MIB

-- Notifications
lmpNotifications OBJECT IDENTIFIER ::= { lmpMIB 0 }
-- Tables, Scalars
lmpObjects       OBJECT IDENTIFIER ::= { lmpMIB 1 }



Dubuc, et al.               Standards Track                    [Page 12]
^L
RFC 4327                     LMP-MIB Module                 January 2006


-- Conformance
lmpConformance   OBJECT IDENTIFIER ::= { lmpMIB 2 }


lmpAdminStatus OBJECT-TYPE
   SYNTAX        INTEGER { up(1), down(2) }
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "The desired operational status of LMP on the node.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { up }
   ::= { lmpObjects 1 }

lmpOperStatus OBJECT-TYPE
   SYNTAX        INTEGER { up(1), down(2) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of LMP on the node."
   ::= { lmpObjects 2 }


-- LMP Neighbor Table

lmpNbrTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpNbrEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the neighbor node(s) to which control
        channels may be established."
   ::= { lmpObjects 3 }

lmpNbrEntry OBJECT-TYPE
   SYNTAX        LmpNbrEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table is created by a LMP-enabled device for
        every pair of nodes that can establish control channels."
   INDEX         { lmpNbrNodeId }
   ::= { lmpNbrTable 1 }

LmpNbrEntry ::= SEQUENCE {
  lmpNbrNodeId              LmpNodeId,
  lmpNbrRetransmitInterval  LmpRetransmitInterval,



Dubuc, et al.               Standards Track                    [Page 13]
^L
RFC 4327                     LMP-MIB Module                 January 2006


  lmpNbrRetryLimit          Unsigned32,
  lmpNbrRetransmitDelta     Unsigned32,
  lmpNbrAdminStatus         INTEGER,
  lmpNbrOperStatus          INTEGER,
  lmpNbrRowStatus           RowStatus,
  lmpNbrStorageType         StorageType
}

lmpNbrNodeId OBJECT-TYPE
   SYNTAX        LmpNodeId
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This is a unique index for an entry in the LmpNbrTable.
        This value represents the remote Node ID."
   ::= { lmpNbrEntry 1 }

lmpNbrRetransmitInterval OBJECT-TYPE
   SYNTAX        LmpRetransmitInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the initial retransmission interval that
        is used for the retransmission of messages that require
        acknowledgement.  This object along with lmpNbrRetryLimit is
        used to implement congestion-handling mechanism as defined in
        Section 10 of the Link Management Protocol specification,
        which is based on RFC 2914."
   REFERENCE
       "Link Management Protocol, RFC 4204.

        Congestion Control Principles, RFC 2914."
   DEFVAL        { 500 }
   ::= { lmpNbrEntry 2 }

lmpNbrRetryLimit OBJECT-TYPE
   SYNTAX        Unsigned32
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the maximum number of times a message
        is transmitted without being acknowledged.  A value of 0 is used
        to indicate that a node should never stop retransmission.
        This object along with lmpNbrRetransmitInterval is
        used to implement congestion-handling mechanism as defined in
        Section 10 of the Link Management Protocol specification,
        which is based on RFC 2914."
   REFERENCE



Dubuc, et al.               Standards Track                    [Page 14]
^L
RFC 4327                     LMP-MIB Module                 January 2006


       "Link Management Protocol, RFC 4204.

        Congestion Control Principles, RFC 2914."
   DEFVAL        { 3 }
   ::= { lmpNbrEntry 3 }

lmpNbrRetransmitDelta OBJECT-TYPE
   SYNTAX        Unsigned32
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object governs the speed with which the sender increases
        the retransmission interval as explained in section 10 of the
        Link Management Protocol specification, which is based on
        RFC 2914.  This value is a power used to express the
        exponential backoff.  The ratio of two successive retransmission
        intervals is (1 + Delta)."
   REFERENCE
       "Link Management Protocol, RFC 4204.

        Congestion Control Principles, RFC 2914."
   DEFVAL        { 1 }
   ::= { lmpNbrEntry 4 }

lmpNbrAdminStatus OBJECT-TYPE
   SYNTAX        INTEGER { up(1), down(2) }
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The desired operational status of LMP to this remote node."
   ::= { lmpNbrEntry 5 }

lmpNbrOperStatus OBJECT-TYPE
   SYNTAX        INTEGER { up(1), down(2) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of LMP to this remote node."
   ::= { lmpNbrEntry 6 }

lmpNbrRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).



Dubuc, et al.               Standards Track                    [Page 15]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        All read-create objects must have valid and consistent
        values before the row can be activated."
   ::= { lmpNbrEntry 7 }

lmpNbrStorageType OBJECT-TYPE
   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpNbrTable.  Conceptual rows having the value
        'permanent' need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpNbrEntry 8 }

-- End of lmpNbrTable


lmpCcHelloIntervalDefault OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default value for the HelloInterval
        parameter used in the Hello protocol keep-alive phase.  It
        indicates how frequently LMP Hello messages will be sent.  It
        is used a the default value for lmpCcHelloInterval.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpObjects 4 }

lmpCcHelloIntervalDefaultMin OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default minimum value for the
        HelloInterval parameter.  It is used as a default value
        for lmpCcHelloIntervalMin.  Implementations should save the
        value of this object in persistent memory so that it survives
        restarts or reboot."
   ::= { lmpObjects 5 }

lmpCcHelloIntervalDefaultMax OBJECT-TYPE
   SYNTAX        LmpInterval



Dubuc, et al.               Standards Track                    [Page 16]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default maximum value for the
        HelloInterval parameter.  It is used as a default value
        for lmpCcHelloIntervalMax.  Implementations should save the
        value of this object in persistent memory so that it survives
        restarts or reboot."
   ::= { lmpObjects 6 }

lmpCcHelloDeadIntervalDefault OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default HelloDeadInterval parameter
        to use in the Hello protocol keep-alive phase.  It indicates
        how long a device should wait before declaring the control
        channel dead.  The HelloDeadInterval parameter should be at
        least three times the value of HelloInterval.  It is used as
        a default value for lmpCcHelloDeadInterval.  Implementations
        should save the value of this object in persistent memory so
        that it survives restarts or reboot."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpObjects 7 }

lmpCcHelloDeadIntervalDefaultMin OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default minimum value for the
        HelloDeadInterval parameter.  It is used as a default value
        for lmpCcHelloDeadIntervalMin.  Implementations should save
        the value of this object in persistent memory so that it
        survives restarts or reboot."
   ::= { lmpObjects 8 }

lmpCcHelloDeadIntervalDefaultMax OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object specifies the default maximum value for the
        HelloDeadInterval parameter.  It is used as a default value
        for lmpCcHelloDeadIntervalMax.  Implementations should save the
        value of this object in persistent memory so that it survives



Dubuc, et al.               Standards Track                    [Page 17]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        restarts or reboot."
   ::= { lmpObjects 9 }


-- LMP Control Channel Table

lmpControlChannelTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpControlChannelEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies LMP control channel information."
   ::= { lmpObjects 10 }

lmpControlChannelEntry OBJECT-TYPE
   SYNTAX        LmpControlChannelEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table is created by a LMP-enabled device for
        every control channel.  Whenever a new entry is created with
        lmpCcIsIf set to true(2), then a corresponding entry is
        created in ifTable as well (see RFC 2863)."
   INDEX         { lmpCcId }
   ::= { lmpControlChannelTable 1 }

LmpControlChannelEntry ::= SEQUENCE {
  lmpCcId                            Unsigned32,
  lmpCcUnderlyingIfIndex             InterfaceIndexOrZero,
  lmpCcIsIf                          TruthValue,
  lmpCcNbrNodeId                     LmpNodeId,
  lmpCcRemoteId                      Unsigned32,
  lmpCcRemoteAddressType             InetAddressType,
  lmpCcRemoteIpAddr                  InetAddress,
  lmpCcSetupRole                     INTEGER,
  lmpCcAuthentication                TruthValue,
  lmpCcHelloInterval                 LmpInterval,
  lmpCcHelloIntervalMin              LmpInterval,
  lmpCcHelloIntervalMax              LmpInterval,
  lmpCcHelloIntervalNegotiated       LmpInterval,
  lmpCcHelloDeadInterval             LmpInterval,
  lmpCcHelloDeadIntervalMin          LmpInterval,
  lmpCcHelloDeadIntervalMax          LmpInterval,
  lmpCcHelloDeadIntervalNegotiated   LmpInterval,
  lmpCcLastChange                    TimeTicks,
  lmpCcAdminStatus                   INTEGER,
  lmpCcOperStatus                    INTEGER,
  lmpCcRowStatus                     RowStatus,



Dubuc, et al.               Standards Track                    [Page 18]
^L
RFC 4327                     LMP-MIB Module                 January 2006


  lmpCcStorageType                   StorageType
}

lmpCcId OBJECT-TYPE
   SYNTAX        Unsigned32 (1..4294967295)
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This value represents the local control channel identifier.
        The control channel identifier is a non-zero 32-bit number."
   ::= { lmpControlChannelEntry 1 }

lmpCcUnderlyingIfIndex OBJECT-TYPE
   SYNTAX        InterfaceIndexOrZero
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "If lmpCcIsIf is set to true(1), this object carries the
        index into the ifTable of the entry that represents the
        LMP interface over which LMP will transmit its traffic.
        If this object is set to zero, but lmpCcIsIf is set to
        true(1), the control channel is not currently associated
        with any underlying interface and the control channel's
        operational status must not be up(1), nor should the
        control channel forward or receive traffic.
        If lmpCcIsIf is set to false(2), this object should be set
        to zero and should be ignored."
   ::= { lmpControlChannelEntry 2 }

lmpCcIsIf OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "In implementations where the control channels are modeled
        as interfaces, the value of this object is true(1) and
        this control channel is represented by an interface in
        the interfaces group table as indicated by the value of
        lmpCcUnderlyingIfIndex.  If control channels are not
        modeled as interfaces, the value of this object is
        false(2) and there is no corresponding interface for
        this control channel in the interfaces group table,
        and the value of lmpCcUnderlyingIfIndex should be
        ignored."
   ::= { lmpControlChannelEntry 3 }

lmpCcNbrNodeId OBJECT-TYPE
   SYNTAX        LmpNodeId



Dubuc, et al.               Standards Track                    [Page 19]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This is the Node ID of the control channel remote node.
        This value either is configured or gets created by the node
        when a Config message is received or when an outgoing Config
        message is acknowledged by the remote node."
   ::= { lmpControlChannelEntry 4 }

lmpCcRemoteId OBJECT-TYPE
   SYNTAX        Unsigned32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This value represents the remote control channel identifier
        (32-bit number).  It is determined during the negotiation
        phase.  A value of zero means that the remote control channel
        identifier has not yet been learnt."
   ::= { lmpControlChannelEntry 5 }

lmpCcRemoteAddressType OBJECT-TYPE
   SYNTAX        InetAddressType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This value represents the remote control channel IP address
        type.  In point-to-point configuration, this value can be set
        to unknown(0)."
   ::= { lmpControlChannelEntry 6 }

lmpCcRemoteIpAddr OBJECT-TYPE
   SYNTAX        InetAddress
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This value represents the remote control channel Internet
        address for numbered control channel.  The type of this
        address is determined by lmpCcRemoteAddressType.
        Control channel must be numbered on non-point-to-point
        configuration.  For point-to-point configuration, the
        remote control channel address can be of type unknown
        in which case this object must be a zero-length string.  The
        lmpCcRemoteId object then identifies the unnumbered
        address."
   ::= { lmpControlChannelEntry 7 }

lmpCcSetupRole OBJECT-TYPE
   SYNTAX        INTEGER { active(1), passive(2) }



Dubuc, et al.               Standards Track                    [Page 20]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The role that this node should take during establishment
        of this control channel.  An active node will initiate
        establishment.  A passive node will wait for the remote node
        to initiate.  A pair of nodes that both take the passive role
        will never establish communications."
   DEFVAL        { active }
   ::= { lmpControlChannelEntry 8 }

lmpCcAuthentication OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object indicates whether the control channel must use
        authentication."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpControlChannelEntry 9 }

lmpCcHelloInterval OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the value of the HelloInterval
        parameter.  The default value for this object should be
        set to lmpCcHelloIntervalDefault."
   ::= { lmpControlChannelEntry 10 }

lmpCcHelloIntervalMin OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the minimum value for the
        HelloInterval parameter.  The default value for this
        object should be set to lmpCcHelloIntervalMinDefault."
   ::= { lmpControlChannelEntry 11 }

lmpCcHelloIntervalMax OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the maximum value for the



Dubuc, et al.               Standards Track                    [Page 21]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        HelloInterval parameter.  The default value for this
        object should be set to lmpCcHelloIntervalMaxDefault."
   ::= { lmpControlChannelEntry 12 }

lmpCcHelloIntervalNegotiated OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "Once the control channel is active, this object represents
        the negotiated HelloInterval value."
   ::= { lmpControlChannelEntry 13 }

lmpCcHelloDeadInterval OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the value of the HelloDeadInterval
        parameter.  The default value for this object should be
        set to lmpCcHelloDeadIntervalDefault."
   ::= { lmpControlChannelEntry 14 }

lmpCcHelloDeadIntervalMin OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the minimum value for the
        HelloDeadInterval parameter.  The default value for this
        object should be set to lmpCcHelloDeadIntervalMinDefault."
   ::= { lmpControlChannelEntry 15 }

lmpCcHelloDeadIntervalMax OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the maximum value for the
        HelloDeadInterval parameter.  The default value for this
        object should be set to lmpCcHelloIntervalMaxDefault."
   ::= { lmpControlChannelEntry 16 }

lmpCcHelloDeadIntervalNegotiated OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 22]
^L
RFC 4327                     LMP-MIB Module                 January 2006


       "Once the control channel is active, this object represents
        the negotiated HelloDeadInterval value."
   ::= { lmpControlChannelEntry 17 }

lmpCcLastChange OBJECT-TYPE
   SYNTAX       TimeTicks
   MAX-ACCESS   read-only
   STATUS       current
   DESCRIPTION
       "The value of sysUpTime at the time the control channel entered
        its current operational state.  If the current state was
        entered prior to the last re-initialization of the local
        network management subsystem, then this object contains a
        zero value."
   ::= { lmpControlChannelEntry 18 }

lmpCcAdminStatus OBJECT-TYPE
   SYNTAX        INTEGER { up(1), down(2) }
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The desired operational status of this control channel."
   ::= { lmpControlChannelEntry 19 }

lmpCcOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                     up(1),
                     down(2),
                     configSnd(3),
                     configRcv(4),
                     active(5),
                     goingDown(6)
                 }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this control channel."
   ::= { lmpControlChannelEntry 20 }

lmpCcRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).
        All read-create objects must have valid and consistent



Dubuc, et al.               Standards Track                    [Page 23]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        values before the row can be activated."
   ::= { lmpControlChannelEntry 21 }

lmpCcStorageType OBJECT-TYPE
   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpControlChannelTable.  Conceptual rows having the value
        'permanent' need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpControlChannelEntry 22 }

-- End of lmpControlChannelTable


-- LMP Control Channel Performance Table

lmpControlChannelPerfTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpControlChannelPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies LMP control channel performance
        counters."
   ::= { lmpObjects 11 }

lmpControlChannelPerfEntry OBJECT-TYPE
   SYNTAX        LmpControlChannelPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table is created by a LMP-enabled device for
        every control channel.  lmpCcCounterDiscontinuityTime is used
        to indicate potential discontinuity for all counter objects
        in this table."
   INDEX         { lmpCcId }
   ::= { lmpControlChannelPerfTable 1 }

LmpControlChannelPerfEntry ::= SEQUENCE {
  lmpCcInOctets                    Counter32,
  lmpCcInDiscards                  Counter32,
  lmpCcInErrors                    Counter32,
  lmpCcOutOctets                   Counter32,
  lmpCcOutDiscards                 Counter32,
  lmpCcOutErrors                   Counter32,



Dubuc, et al.               Standards Track                    [Page 24]
^L
RFC 4327                     LMP-MIB Module                 January 2006


  lmpCcConfigReceived              Counter32,
  lmpCcConfigSent                  Counter32,
  lmpCcConfigRetransmit            Counter32,
  lmpCcConfigAckReceived           Counter32,
  lmpCcConfigAckSent               Counter32,
  lmpCcConfigNackReceived          Counter32,
  lmpCcConfigNackSent              Counter32,
  lmpCcHelloReceived               Counter32,
  lmpCcHelloSent                   Counter32,
  lmpCcBeginVerifyReceived         Counter32,
  lmpCcBeginVerifySent             Counter32,
  lmpCcBeginVerifyRetransmit       Counter32,
  lmpCcBeginVerifyAckReceived      Counter32,
  lmpCcBeginVerifyAckSent          Counter32,
  lmpCcBeginVerifyNackReceived     Counter32,
  lmpCcBeginVerifyNackSent         Counter32,
  lmpCcEndVerifyReceived           Counter32,
  lmpCcEndVerifySent               Counter32,
  lmpCcEndVerifyRetransmit         Counter32,
  lmpCcEndVerifyAckReceived        Counter32,
  lmpCcEndVerifyAckSent            Counter32,
  lmpCcTestStatusSuccessReceived   Counter32,
  lmpCcTestStatusSuccessSent       Counter32,
  lmpCcTestStatusSuccessRetransmit Counter32,
  lmpCcTestStatusFailureReceived   Counter32,
  lmpCcTestStatusFailureSent       Counter32,
  lmpCcTestStatusFailureRetransmit Counter32,
  lmpCcTestStatusAckReceived       Counter32,
  lmpCcTestStatusAckSent           Counter32,
  lmpCcLinkSummaryReceived         Counter32,
  lmpCcLinkSummarySent             Counter32,
  lmpCcLinkSummaryRetransmit       Counter32,
  lmpCcLinkSummaryAckReceived      Counter32,
  lmpCcLinkSummaryAckSent          Counter32,
  lmpCcLinkSummaryNackReceived     Counter32,
  lmpCcLinkSummaryNackSent         Counter32,
  lmpCcChannelStatusReceived       Counter32,
  lmpCcChannelStatusSent           Counter32,
  lmpCcChannelStatusRetransmit     Counter32,
  lmpCcChannelStatusAckReceived    Counter32,
  lmpCcChannelStatusAckSent        Counter32,
  lmpCcChannelStatusReqReceived    Counter32,
  lmpCcChannelStatusReqSent        Counter32,
  lmpCcChannelStatusReqRetransmit  Counter32,
  lmpCcChannelStatusRspReceived    Counter32,
  lmpCcChannelStatusRspSent        Counter32,
  lmpCcCounterDiscontinuityTime    TimeStamp
}



Dubuc, et al.               Standards Track                    [Page 25]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpCcInOctets OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of LMP message octets received on the
             control channel."
    ::= { lmpControlChannelPerfEntry 1 }

lmpCcInDiscards OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of inbound packets that were chosen to be
             discarded even though no errors had been detected.  One
             possible reason for discarding such a packet could be to
             free up buffer space."
    ::= { lmpControlChannelPerfEntry 2 }

lmpCcInErrors OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The number of inbound packets that contained errors
             preventing them from being processed by LMP."
    ::= { lmpControlChannelPerfEntry 3 }

lmpCcOutOctets OBJECT-TYPE
    SYNTAX       Counter32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The total number of LMP message octets transmitted out of
             the control channel."
    ::= { lmpControlChannelPerfEntry 4 }

lmpCcOutDiscards OBJECT-TYPE
    SYNTAX       Counter32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The number of outbound packets that were chosen to be
             discarded even though no errors had been detected to
             prevent their being transmitted.  One possible reason
             for discarding such a packet could be to free up buffer
             space."



Dubuc, et al.               Standards Track                    [Page 26]
^L
RFC 4327                     LMP-MIB Module                 January 2006


    ::= { lmpControlChannelPerfEntry 5 }

lmpCcOutErrors OBJECT-TYPE
    SYNTAX       Counter32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The number of outbound packets that could not be
             transmitted because of errors."
    ::= { lmpControlChannelPerfEntry 6 }

lmpCcConfigReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Config messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 7 }

lmpCcConfigSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Config messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 8 }

lmpCcConfigRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Config messages that
        have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 9 }

lmpCcConfigAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ConfigAck messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 10 }

lmpCcConfigAckSent OBJECT-TYPE



Dubuc, et al.               Standards Track                    [Page 27]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ConfigAck messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 11 }

lmpCcConfigNackReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ConfigNack messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 12 }

lmpCcConfigNackSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ConfigNack messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 13 }

lmpCcHelloReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Hello messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 14 }

lmpCcHelloSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Hello messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 15 }

lmpCcBeginVerifyReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current



Dubuc, et al.               Standards Track                    [Page 28]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   DESCRIPTION
       "This object counts the number of BeginVerify messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 16 }

lmpCcBeginVerifySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerify messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 17 }

lmpCcBeginVerifyRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerify messages that
        have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 18 }

lmpCcBeginVerifyAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyAck messages that
        have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 19 }

lmpCcBeginVerifyAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyAck messages that
        have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 20 }

lmpCcBeginVerifyNackReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyNack messages that
        have been received on this control channel."



Dubuc, et al.               Standards Track                    [Page 29]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   ::= { lmpControlChannelPerfEntry 21 }

lmpCcBeginVerifyNackSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyNack messages that
        have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 22 }

lmpCcEndVerifyReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that have
        been received on this control channel."
   ::= { lmpControlChannelPerfEntry 23 }

lmpCcEndVerifySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that have
        been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 24 }

lmpCcEndVerifyRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that
        have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 25 }

lmpCcEndVerifyAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerifyAck messages that
        have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 26 }

lmpCcEndVerifyAckSent OBJECT-TYPE



Dubuc, et al.               Standards Track                    [Page 30]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerifyAck messages that
        have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 27 }

lmpCcTestStatusSuccessReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 28 }

lmpCcTestStatusSuccessSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 29 }

lmpCcTestStatusSuccessRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 30 }

lmpCcTestStatusFailureReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 31 }

lmpCcTestStatusFailureSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current



Dubuc, et al.               Standards Track                    [Page 31]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 32 }

lmpCcTestStatusFailureRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 33 }

lmpCcTestStatusAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusAck messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 34 }

lmpCcTestStatusAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusAck messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 35 }

lmpCcLinkSummaryReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 36 }

lmpCcLinkSummarySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages
        that have been sent on this control channel."



Dubuc, et al.               Standards Track                    [Page 32]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   ::= { lmpControlChannelPerfEntry 37 }

lmpCcLinkSummaryRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages that
        have been retransmitted over this control channel."
   ::= { lmpControlChannelPerfEntry 38 }

lmpCcLinkSummaryAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryAck messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 39 }

lmpCcLinkSummaryAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryAck messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 40 }

lmpCcLinkSummaryNackReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryNack messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 41 }

lmpCcLinkSummaryNackSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryNack messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 42 }

lmpCcChannelStatusReceived OBJECT-TYPE



Dubuc, et al.               Standards Track                    [Page 33]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 43 }

lmpCcChannelStatusSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 44 }

lmpCcChannelStatusRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages
        that have been retransmitted on this control channel."
   ::= { lmpControlChannelPerfEntry 45 }

lmpCcChannelStatusAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusAck messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 46 }

lmpCcChannelStatusAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 47 }

lmpCcChannelStatusReqReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current



Dubuc, et al.               Standards Track                    [Page 34]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 48 }

lmpCcChannelStatusReqSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 49 }

lmpCcChannelStatusReqRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been retransmitted on this control channel."
   ::= { lmpControlChannelPerfEntry 50 }

lmpCcChannelStatusRspReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusResponse messages
        that have been received on this control channel."
   ::= { lmpControlChannelPerfEntry 51 }

lmpCcChannelStatusRspSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusResponse messages
        that have been sent on this control channel."
   ::= { lmpControlChannelPerfEntry 52 }

lmpCcCounterDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime on the most recent occasion at which
         any one or more of this control channel's counters suffered a



Dubuc, et al.               Standards Track                    [Page 35]
^L
RFC 4327                     LMP-MIB Module                 January 2006


         discontinuity.  The relevant counters are the specific
         instances associated with this control channel of any
         Counter32 object contained in the lmpControlChannelPerfTable.
         If no such discontinuities have occurred since the last re-
         initialization of the local management subsystem, then this
         object contains a zero value."
    ::= { lmpControlChannelPerfEntry 53 }

-- End of lmpControlChannelPerfTable


-- LMP TE Link Table

lmpTeLinkTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpTeLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the LMP-specific TE link information.
        Overall TE link information is kept in three separate tables:
        ifTable for interface-specific information, lmpTeLinkTable
        for LMP specific information, and teLinkTable for generic
        TE link information.  ifIndex is the common index to all
        tables."
   ::= { lmpObjects 12 }

lmpTeLinkEntry OBJECT-TYPE
   SYNTAX        LmpTeLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table exists for each ifEntry with an
        ifType of teLink(200) that is managed by LMP.  An ifEntry with
        an ifIndex must exist before the corresponding lmpTeLinkEntry is
        created.  If a TE link entry in the ifTable is destroyed, then
        so is the corresponding entry in the lmpTeLinkTable.  The
        administrative status value is controlled from the ifEntry.
        Setting the administrative status to testing prompts LMP to
        start link verification on the TE link.  Information about the
        TE link that is not LMP specific is contained in teLinkTable of
        the TE-LINK-STD-MIB MIB module."
   INDEX         { ifIndex }
   ::= { lmpTeLinkTable 1 }

LmpTeLinkEntry ::= SEQUENCE {
  lmpTeLinkNbrRemoteNodeId  LmpNodeId,
  lmpTeLinkVerification     TruthValue,
  lmpTeLinkFaultManagement  TruthValue,



Dubuc, et al.               Standards Track                    [Page 36]
^L
RFC 4327                     LMP-MIB Module                 January 2006


  lmpTeLinkDwdm             TruthValue,
  lmpTeLinkOperStatus       INTEGER,
  lmpTeLinkRowStatus        RowStatus,
  lmpTeLinkStorageType      StorageType
}

lmpTeLinkNbrRemoteNodeId OBJECT-TYPE
   SYNTAX        LmpNodeId
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This is the Node ID of the TE link remote node.  This value
        may be learned during control channel parameter negotiation
        phase (in the Config message).  Node ID is an address whose
        type must be IPv4."
   ::= { lmpTeLinkEntry 1 }

lmpTeLinkVerification OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object indicates if the LMP link verification procedure
        is enabled for this TE link."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpTeLinkEntry 2 }

lmpTeLinkFaultManagement OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object indicates if the LMP fault management procedure
        is enabled on this TE link."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpTeLinkEntry 3 }

lmpTeLinkDwdm OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object indicates if the LMP DWDM procedure is enabled
        on this TE link."
   REFERENCE
       "Link Management Protocol (LMP) for Dense Wavelength Division



Dubuc, et al.               Standards Track                    [Page 37]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        Multiplexing (DWDM) Optical Line Systems, RFC 4209"
   ::= { lmpTeLinkEntry 4 }

lmpTeLinkOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                   up(1), down(2), testing(3), init(4), degraded(5)
                 }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this TE link.  The status
        is set to testing when the TE link is performing link
        verification.  A degraded state indicates that there is
        no active control channel between the pair of nodes that
        form the endpoints of the TE link, but yet at least one
        data-bearing link on the TE link is allocated."
   ::= { lmpTeLinkEntry 5 }

lmpTeLinkRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).
        All read-create objects must have valid and consistent
        values before the row can be activated."
   ::= { lmpTeLinkEntry 6 }

lmpTeLinkStorageType OBJECT-TYPE
   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpTeLinkTable.  Conceptual rows having the value
        'permanent' need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpTeLinkEntry 7 }

-- End of lmpTeLinkTable


lmpGlobalLinkVerificationInterval OBJECT-TYPE
   SYNTAX        Unsigned32
   UNITS         "milliseconds"



Dubuc, et al.               Standards Track                    [Page 38]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "This object indicates how often the link verification
        procedure is executed.  The interval is in milliseconds.
        A value of 0 is used to indicate that the link
        verification procedure should not be executed.  The
        interval specified in this object should be large enough
        to allow the verification procedure to be completed
        before the start of the next interval.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   ::= { lmpObjects 13 }


-- LMP Link Verification Table

lmpLinkVerificationTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpLinkVerificationEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies TE link information associated with the
        LMP verification procedure."
   ::= { lmpObjects 14 }

lmpLinkVerificationEntry OBJECT-TYPE
   SYNTAX        LmpLinkVerificationEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table is created by an LMP-enabled device for
        every TE link that supports the LMP verification
        procedure."
   INDEX         { ifIndex }
   ::= { lmpLinkVerificationTable 1 }

LmpLinkVerificationEntry ::= SEQUENCE {
  lmpLinkVerifyInterval           LmpInterval,
  lmpLinkVerifyDeadInterval       LmpInterval,
  lmpLinkVerifyTransportMechanism BITS,
  lmpLinkVerifyAllLinks           TruthValue,
  lmpLinkVerifyTransmissionRate   Unsigned32,
  lmpLinkVerifyWavelength         Unsigned32,
  lmpLinkVerifyRowStatus          RowStatus,
  lmpLinkVerifyStorageType        StorageType
}




Dubuc, et al.               Standards Track                    [Page 39]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpLinkVerifyInterval OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the VerifyInterval parameter used
        in the LMP link verification process.  It indicates the
        interval at which the Test messages are sent."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpLinkVerificationEntry 1 }

lmpLinkVerifyDeadInterval OBJECT-TYPE
   SYNTAX        LmpInterval
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This object specifies the VerifyDeadInterval parameter used
        in the verification of the physical connectivity of data-
        bearing links.  It specifies the observation period used to
        detect a Test message at the remote node."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpLinkVerificationEntry 2 }

lmpLinkVerifyTransportMechanism OBJECT-TYPE
   SYNTAX        BITS {
                     -- All encoding types:
                     payload(0),
                     -- SONET/SDH encoding type:
                     dccSectionOverheadBytes(1),
                     dccLineOverheadBytes(2),
                     j0Trace(3),
                     j1Trace(4),
                     j2Trace(5)
                 }
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This defines the transport mechanism for the Test messages.  The
        scope of this bit mask is restricted to each link encoding
        type.  The local node will set the bits corresponding to the
        various mechanisms it can support for transmitting LMP Test
        messages.  The receiver chooses the appropriate mechanism in the
        BeginVerifyAck message."
   REFERENCE
       "Link Management Protocol, RFC 4204




Dubuc, et al.               Standards Track                    [Page 40]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        Synchronous Optical Network (SONET)/Synchronous Digital
        Hierarchy (SDH) Encoding for Link Management Protocol (LMP)
        Test Messages, RFC 4207"
   ::= { lmpLinkVerificationEntry 3 }

lmpLinkVerifyAllLinks OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "A value of true(2) for this object indicates that the
        verification process checks all unallocated links, otherwise
        only the new ports or component links that have been added to
        this TE link are verified."
   ::= { lmpLinkVerificationEntry 4 }

lmpLinkVerifyTransmissionRate OBJECT-TYPE
   SYNTAX        Unsigned32
   UNITS         "bytes per second"
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This is the transmission rate of the data link over which
        the Test messages will be transmitted and is expressed in
        bytes per second."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpLinkVerificationEntry 5 }

lmpLinkVerifyWavelength OBJECT-TYPE
   SYNTAX        Unsigned32
   UNITS         "nanometers"
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This value corresponds to the wavelength at
        which the Test messages will be transmitted and is
        measured in nanometers (nm).  If each data-bearing link
        corresponds to a separate wavelength, then this value should
        be set to 0."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpLinkVerificationEntry 6 }

lmpLinkVerifyRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current



Dubuc, et al.               Standards Track                    [Page 41]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).
        All read-create objects must have valid and consistent
        values before the row can be activated."
   ::= { lmpLinkVerificationEntry 7 }

lmpLinkVerifyStorageType OBJECT-TYPE
   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpLinkVerificationTable.  Conceptual rows having the value
        'permanent' need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpLinkVerificationEntry 8 }

-- End of lmpLinkVerificationTable


-- LMP TE Link Performance Table

lmpTeLinkPerfTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpTeLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies LMP TE link performance counters."
   ::= { lmpObjects 15 }

lmpTeLinkPerfEntry OBJECT-TYPE
   SYNTAX        LmpTeLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table is created by an LMP-enabled device for
        every TE link.  lmpTeCounterDiscontinuityTime is used
        to indicate potential discontinuity for all counter objects
        in this table."
   INDEX         { ifIndex }
   ::= { lmpTeLinkPerfTable 1 }

LmpTeLinkPerfEntry ::= SEQUENCE {
  lmpTeInOctets                    Counter32,
  lmpTeOutOctets                   Counter32,



Dubuc, et al.               Standards Track                    [Page 42]
^L
RFC 4327                     LMP-MIB Module                 January 2006


  lmpTeBeginVerifyReceived         Counter32,
  lmpTeBeginVerifySent             Counter32,
  lmpTeBeginVerifyRetransmit       Counter32,
  lmpTeBeginVerifyAckReceived      Counter32,
  lmpTeBeginVerifyAckSent          Counter32,
  lmpTeBeginVerifyNackReceived     Counter32,
  lmpTeBeginVerifyNackSent         Counter32,
  lmpTeEndVerifyReceived           Counter32,
  lmpTeEndVerifySent               Counter32,
  lmpTeEndVerifyRetransmit         Counter32,
  lmpTeEndVerifyAckReceived        Counter32,
  lmpTeEndVerifyAckSent            Counter32,
  lmpTeTestStatusSuccessReceived   Counter32,
  lmpTeTestStatusSuccessSent       Counter32,
  lmpTeTestStatusSuccessRetransmit Counter32,
  lmpTeTestStatusFailureReceived   Counter32,
  lmpTeTestStatusFailureSent       Counter32,
  lmpTeTestStatusFailureRetransmit Counter32,
  lmpTeTestStatusAckReceived       Counter32,
  lmpTeTestStatusAckSent           Counter32,
  lmpTeLinkSummaryReceived         Counter32,
  lmpTeLinkSummarySent             Counter32,
  lmpTeLinkSummaryRetransmit       Counter32,
  lmpTeLinkSummaryAckReceived      Counter32,
  lmpTeLinkSummaryAckSent          Counter32,
  lmpTeLinkSummaryNackReceived     Counter32,
  lmpTeLinkSummaryNackSent         Counter32,
  lmpTeChannelStatusReceived       Counter32,
  lmpTeChannelStatusSent           Counter32,
  lmpTeChannelStatusRetransmit     Counter32,
  lmpTeChannelStatusAckReceived    Counter32,
  lmpTeChannelStatusAckSent        Counter32,
  lmpTeChannelStatusReqReceived    Counter32,
  lmpTeChannelStatusReqSent        Counter32,
  lmpTeChannelStatusReqRetransmit  Counter32,
  lmpTeChannelStatusRspReceived    Counter32,
  lmpTeChannelStatusRspSent        Counter32,
  lmpTeCounterDiscontinuityTime    TimeStamp
}

lmpTeInOctets OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The total number of LMP message octets received for
             this TE link."
    ::= { lmpTeLinkPerfEntry 1 }



Dubuc, et al.               Standards Track                    [Page 43]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpTeOutOctets OBJECT-TYPE
    SYNTAX       Counter32
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The total number of LMP message octets transmitted out
             for this TE link."
    ::= { lmpTeLinkPerfEntry 2 }

lmpTeBeginVerifyReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerify messages that have
        been received for this TE link."
   ::= { lmpTeLinkPerfEntry 3 }

lmpTeBeginVerifySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerify messages that have
        been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 4 }

lmpTeBeginVerifyRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerify messages that
        have been retransmitted for this TE link."
   ::= { lmpTeLinkPerfEntry 5 }

lmpTeBeginVerifyAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyAck messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 6 }

lmpTeBeginVerifyAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only



Dubuc, et al.               Standards Track                    [Page 44]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyAck messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 7 }

lmpTeBeginVerifyNackReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyNack messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 8 }

lmpTeBeginVerifyNackSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of BeginVerifyNack messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 9 }

lmpTeEndVerifyReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that have
        been received for this TE link."
   ::= { lmpTeLinkPerfEntry 10 }

lmpTeEndVerifySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that have
        been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 11 }

lmpTeEndVerifyRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerify messages that



Dubuc, et al.               Standards Track                    [Page 45]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        have been retransmitted over this control channel."
   ::= { lmpTeLinkPerfEntry 12 }

lmpTeEndVerifyAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerifyAck messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 13 }

lmpTeEndVerifyAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of EndVerifyAck messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 14 }

lmpTeTestStatusSuccessReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 15 }

lmpTeTestStatusSuccessSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 16 }

lmpTeTestStatusSuccessRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusSuccess messages
        that have been retransmitted for this TE link."
   ::= { lmpTeLinkPerfEntry 17 }




Dubuc, et al.               Standards Track                    [Page 46]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpTeTestStatusFailureReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 18 }

lmpTeTestStatusFailureSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 19 }

lmpTeTestStatusFailureRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusFailure messages
        that have been retransmitted on this TE link."
   ::= { lmpTeLinkPerfEntry 20 }

lmpTeTestStatusAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusAck messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 21 }

lmpTeTestStatusAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of TestStatusAck messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 22 }

lmpTeLinkSummaryReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only



Dubuc, et al.               Standards Track                    [Page 47]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 23 }

lmpTeLinkSummarySent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 24 }

lmpTeLinkSummaryRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummary messages that
        have been retransmitted over this control channel."
   ::= { lmpTeLinkPerfEntry 25 }

lmpTeLinkSummaryAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryAck messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 26 }

lmpTeLinkSummaryAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryAck messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 27 }

lmpTeLinkSummaryNackReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryNack messages that



Dubuc, et al.               Standards Track                    [Page 48]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 28 }

lmpTeLinkSummaryNackSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of LinkSummaryNack messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 29 }

lmpTeChannelStatusReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages that
        have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 30 }

lmpTeChannelStatusSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages that
        have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 31 }

lmpTeChannelStatusRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages that
        have been retransmitted for this TE link."
   ::= { lmpTeLinkPerfEntry 32 }

lmpTeChannelStatusAckReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusAck messages
        that have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 33 }




Dubuc, et al.               Standards Track                    [Page 49]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpTeChannelStatusAckSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatus messages
        that have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 34 }

lmpTeChannelStatusReqReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 35 }

lmpTeChannelStatusReqSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 36 }

lmpTeChannelStatusReqRetransmit OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusRequest messages
        that have been retransmitted for this TE link."
   ::= { lmpTeLinkPerfEntry 37 }

lmpTeChannelStatusRspReceived OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusResponse messages
        that have been received for this TE link."
   ::= { lmpTeLinkPerfEntry 38 }

lmpTeChannelStatusRspSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only



Dubuc, et al.               Standards Track                    [Page 50]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   STATUS        current
   DESCRIPTION
       "This object counts the number of ChannelStatusResponse messages
        that have been sent for this TE link."
   ::= { lmpTeLinkPerfEntry 39 }

lmpTeCounterDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime on the most recent occasion at which
         any one or more of this TE link's counters suffered a
         discontinuity.  The relevant counters are the specific
         instances associated with this TE link of any Counter32
         object contained in the lmpTeLinkPerfTable.  If
         no such discontinuities have occurred since the last re-
         initialization of the local management subsystem, then this
         object contains a zero value."
    ::= { lmpTeLinkPerfEntry 40 }

-- End of lmpTeLinkPerfTable


-- LMP Data Link Table

lmpDataLinkTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpDataLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the data-bearing links managed by the
        LMP."
   ::= { lmpObjects 16 }

lmpDataLinkEntry OBJECT-TYPE
   SYNTAX        LmpDataLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table exists for each ifEntry that represents
        a data-bearing link.  An ifEntry with an ifIndex must exist
        before the corresponding lmpDataLinkEntry is created.
        If an entry representing the data-bearing link is destroyed in
        the ifTable, then so is the corresponding entry in the
        lmpDataLinkTable.  The administrative status value is
        controlled from the ifEntry.  The index to this table is also
        used to get information in the componentLinkTable



Dubuc, et al.               Standards Track                    [Page 51]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        of the TE-LINK-STD-MIB MIB module."
   INDEX         { ifIndex }
   ::= { lmpDataLinkTable 1 }

LmpDataLinkEntry ::= SEQUENCE {
  lmpDataLinkType               INTEGER,
  lmpDataLinkAddressType        InetAddressType,
  lmpDataLinkIpAddr             InetAddress,
  lmpDataLinkRemoteIpAddress    InetAddress,
  lmpDataLinkRemoteIfId         InterfaceIndexOrZero,
  lmpDataLinkEncodingType       TeLinkEncodingType,
  lmpDataLinkActiveOperStatus   INTEGER,
  lmpDataLinkPassiveOperStatus  INTEGER,
  lmpDataLinkRowStatus          RowStatus,
  lmpDataLinkStorageType        StorageType
}

lmpDataLinkType OBJECT-TYPE
   SYNTAX        INTEGER {
                     port(1),
                     componentLink(2)
                 }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This attribute specifies whether this data-bearing link is
        a port or a component link.  Component link are multiplex
        capable, whereas ports are not multiplex capable."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 1 }

lmpDataLinkAddressType OBJECT-TYPE
   SYNTAX        InetAddressType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This attribute specifies the data-bearing link IP address
        type.  If the data-bearing link is unnumbered, the address
        type must be set to unknown(0)."
   ::= { lmpDataLinkEntry 2 }

lmpDataLinkIpAddr OBJECT-TYPE
   SYNTAX        InetAddress
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The local Internet address for numbered links.  The type



Dubuc, et al.               Standards Track                    [Page 52]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        of this address is determined by the value of
        lmpDataLinkAddressType object.

        For IPv4 and IPv6 numbered links, this object represents
        the local IP address associated with the data-bearing
        link.  For an unnumbered link, the local address is
        of type unknown and this object is set to the zero-length
        string and the ifIndex object then identifies the
        unnumbered address."
   ::= { lmpDataLinkEntry 3 }

lmpDataLinkRemoteIpAddress OBJECT-TYPE
   SYNTAX        InetAddress
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The remote Internet address for numbered data-bearing links.
        The type of this address is determined by the
        lmpDataLinkAddressType object.

        For IPv4 and IPv6 numbered links, this object represents the
        remote IP address associated with the data-bearing link.  For
        an unnumbered link, the remote address is of type unknown
        and this object is set to the zero-length string and the
        lmpDataLinkRemoteIfId object then identifies the unnumbered
        address.

        This information is either configured manually or
        communicated by the remote node during the link verification
        procedure."
   ::= { lmpDataLinkEntry 4 }

lmpDataLinkRemoteIfId OBJECT-TYPE
   SYNTAX        InterfaceIndexOrZero
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "Interface identifier of the remote end point.  This
        information is either configured manually or
        communicated by the remote node during the link verification
        procedure."
   ::= { lmpDataLinkEntry 5 }

lmpDataLinkEncodingType OBJECT-TYPE
   SYNTAX        TeLinkEncodingType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 53]
^L
RFC 4327                     LMP-MIB Module                 January 2006


       "The encoding type of the data-bearing link."
   REFERENCE
       "Generalized MPLS Signaling Functional Description, RFC 3471"
   ::= { lmpDataLinkEntry 6 }

lmpDataLinkActiveOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                     upAlloc(1),
                     upFree(2),
                     down(3),
                     testing(4) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this data-bearing link
        (active FSM)."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 7 }

lmpDataLinkPassiveOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                     upAlloc(1),
                     upFree(2),
                     down(3),
                     psvTst(4) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this data-bearing link
        (passive FSM)."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 8 }

lmpDataLinkRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).
        All read-create objects must have valid and consistent
        values before the row can be activated."
   ::= { lmpDataLinkEntry 9 }

lmpDataLinkStorageType OBJECT-TYPE



Dubuc, et al.               Standards Track                    [Page 54]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpDataLinkTable.  Conceptual rows having the value
        'permanent' need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpDataLinkEntry 10 }

-- End of lmpDataLinkTable


-- LMP Data Link Performance Table

lmpDataLinkPerfTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpDataLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the data-bearing links LMP performance
        counters."
   ::= { lmpObjects 17 }

lmpDataLinkPerfEntry OBJECT-TYPE
   SYNTAX        LmpDataLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table contains information about
        the LMP performance counters for the data-bearing links.
        lmpDataLinkDiscontinuityTime is used to indicate potential
        discontinuity for all counter objects in this table."
   INDEX         { ifIndex }
   ::= { lmpDataLinkPerfTable 1 }

LmpDataLinkPerfEntry ::= SEQUENCE {
  lmpDataLinkTestReceived        Counter32,
  lmpDataLinkTestSent            Counter32,
  lmpDataLinkActiveTestSuccess   Counter32,
  lmpDataLinkActiveTestFailure   Counter32,
  lmpDataLinkPassiveTestSuccess  Counter32,
  lmpDataLinkPassiveTestFailure  Counter32,
  lmpDataLinkDiscontinuityTime   TimeStamp
}

lmpDataLinkTestReceived OBJECT-TYPE



Dubuc, et al.               Standards Track                    [Page 55]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Test messages that have
        been received on this data-bearing link."
   ::= { lmpDataLinkPerfEntry 1 }

lmpDataLinkTestSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Test messages that have
        been sent on this data-bearing link."
   ::= { lmpDataLinkPerfEntry 2 }

lmpDataLinkActiveTestSuccess OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that were successful on the active side of this data-
        bearing link."
   ::= { lmpDataLinkPerfEntry 3 }

lmpDataLinkActiveTestFailure OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that failed on the active side of this data-bearing link."
   ::= { lmpDataLinkPerfEntry 4 }

lmpDataLinkPassiveTestSuccess OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that were successful on the passive side of this data-
        bearing link."
   ::= { lmpDataLinkPerfEntry 5 }

lmpDataLinkPassiveTestFailure OBJECT-TYPE
   SYNTAX        Counter32



Dubuc, et al.               Standards Track                    [Page 56]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that failed on the passive side of this data-bearing link."
   ::= { lmpDataLinkPerfEntry 6 }

lmpDataLinkDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime on the most recent occasion at which
         any one or more of this data-bearing link's counters suffered
         a discontinuity.  The relevant counters are the specific
         instances associated with this data-bearing link of any
         Counter32 object contained in the lmpDataLinkPerfTable.  If
         no such discontinuities have occurred since the last re-
         initialization of the local management subsystem, then this
         object contains a zero value."
    ::= { lmpDataLinkPerfEntry 7 }

-- End of lmpDataLinkPerfTable


-- Notification Configuration

lmpNotificationMaxRate OBJECT-TYPE
   SYNTAX       Unsigned32
   MAX-ACCESS   read-write
   STATUS       current
   DESCRIPTION
       "The LMP notification rate depends on the size of the network,
        the type of links, the network configuration, the
        reliability of the network, etc.

        When designing this MIB, care has been taken to minimize the
        amount of notifications generated for LMP purposes.  Wherever
        possible, notifications are state driven, meaning the
        notifications are sent only when the system changes state.
        The only notifications that are repeated and could cause a
        problem as far as congestion is concerned are the ones
        associated with data link verification.
        Without any considerations to handling of these
        notifications, a problem may arise if the number of data
        links is high.  Since the data link verification notifications
        can happen only once per data link per link verification
        interval, the notification rate should be sustainable if one



Dubuc, et al.               Standards Track                    [Page 57]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        chooses an appropriate link verification interval for a given
        network configuration.  For instance, a network of 100 nodes
        with 5 links of 128 wavelengths each and a link verification
        of 1 minute with no more than 10% of the links failed at any
        given time would have 1 notification per second sent from
        each node, or 100 notifications per second for the whole
        network.  The rest of the notifications are negligible
        compared to this number.

        To alleviate the congestion problem, the
        lmpNotificationMaxRate object can be used to implement a
        throttling mechanism.  It is also possible to enable/disable
        certain type of notifications.

        This variable indicates the maximum number of
        notifications issued per minute.  If events occur
        more rapidly, the implementation may simply fail to
        emit these notifications during that period, or may
        queue them until an appropriate time.  A value of 0
        means no throttling is applied and events may be
        notified at the rate at which they occur.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   ::= { lmpObjects 18 }

lmpLinkPropertyNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpTeLinkPropertyMismatch
        and lmpDataLinkPropertyMismatch notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 19 }

lmpUnprotectedNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpUnprotected notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in



Dubuc, et al.               Standards Track                    [Page 58]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 20 }

lmpCcUpDownNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the generation of
        lmpControlChannelUp and lmpControlChannelDown notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 21 }

lmpTeLinkNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpTeLinkDegraded and lmpTeLinkNotDegraded
        notifications, otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 22 }

lmpDataLinkNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpDataLinkVerificationFailure
        notification, otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 23 }


-- Notifications

-- Link Property Mismatch Notifications




Dubuc, et al.               Standards Track                    [Page 59]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpTeLinkPropertyMismatch NOTIFICATION-TYPE
   OBJECTS       { teLinkRemoteIpAddr,
                   teLinkIncomingIfId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a TE link property
        mismatch is detected on the node.  The received remote TE link
        ID of the misconfigured TE link is represented by either
        teLinkRemoteIpAddr or teLinkIncomingIfId depending on whether
        the TE link is numbered or unnumbered.  This notification
        should not be sent unless lmpLinkPropertyNotificationsEnabled
        is true.  It is recommended that this notification be reported
        only the first time a mismatch is detected.  Otherwise, for a
        given TE link, this notification can occur no more than once
        per verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 1 }

lmpDataLinkPropertyMismatch NOTIFICATION-TYPE
   OBJECTS       { lmpDataLinkType, lmpDataLinkRemoteIfId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a data-bearing link
        property mismatch is detected on the node.  lmpDataLinkType
        is used to identify the local identifiers associated with
        the data link (the data link interface index can be used
        to determine the TE link interface index as this
        relationship is captured in the interface stack table).
        The remote entity interface ID is the remote entity
        interface ID received in the LinkSummary message.
        This notification should not be sent unless
        lmpLinkPropertyNotificationsEnabled is true.  It is
        recommended that this notification be reported only the
        first time a mismatch is detected.  Otherwise, for a given
        data link, this notification can occur no more than once
        per verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 2 }

-- Neighbor Notification

lmpUnprotected NOTIFICATION-TYPE
   OBJECTS       { lmpCcNbrNodeId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when there are more than one
        control channels between LMP neighbors and the last redundant
        control channel has failed.  If the remaining operational
        control channel fails, then there will be no more control
        channels between the pair of nodes and all the TE links



Dubuc, et al.               Standards Track                    [Page 60]
^L
RFC 4327                     LMP-MIB Module                 January 2006


        between the pair of nodes will go to degraded state.  This
        notification should not be sent unless
        lmpUnprotectedNotificationsEnabled is set to true."
   ::= { lmpNotifications 3 }

-- Control Channel Notifications

lmpControlChannelUp NOTIFICATION-TYPE
   OBJECTS       { lmpCcAdminStatus, lmpCcOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a control
        channel transitions to the up operational state.  This
        notification should not be sent unless
        lmpCcUpDownNotificationsEnabled is true."
   ::= { lmpNotifications 4 }

lmpControlChannelDown NOTIFICATION-TYPE
   OBJECTS       { lmpCcAdminStatus, lmpCcOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a control channel
        transitions out of the up operational state.  This
        notification should not be sent unless
        lmpCcUpDownNotificationsEnabled is true."
   ::= { lmpNotifications 5 }

-- TE Link Notification

lmpTeLinkDegraded NOTIFICATION-TYPE
   OBJECTS       { lmpTeLinkOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a lmpTeLinkOperStatus
        object for a TE link enters the degraded state.  This
        notification should not be sent unless
        lmpTeLinkNotificationsEnabled is true."
   ::= { lmpNotifications 6 }

lmpTeLinkNotDegraded NOTIFICATION-TYPE
   OBJECTS       { lmpTeLinkOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a lmpTeLinkOperStatus
        object for a TE link leaves the degraded state.  This
        notification should not be sent unless
        lmpTeLinkNotificationsEnabled is true."
   ::= { lmpNotifications 7 }



Dubuc, et al.               Standards Track                    [Page 61]
^L
RFC 4327                     LMP-MIB Module                 January 2006


-- Data-bearing Link Notification

lmpDataLinkVerificationFailure NOTIFICATION-TYPE
   OBJECTS       { lmpDataLinkActiveOperStatus,
                   lmpDataLinkPassiveOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a data-bearing
        link verification fails.  This notification should not be sent
        unless lmpDataLinkNotificationsEnabled is true.  For a given
        data link, this notification can occur no more than once per
        verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 8 }

-- End of notifications


-- Module compliance

lmpCompliances
   OBJECT IDENTIFIER ::= { lmpConformance 1 }

lmpGroups
   OBJECT IDENTIFIER ::= { lmpConformance 2 }

lmpModuleFullCompliance MODULE-COMPLIANCE
   STATUS current
   DESCRIPTION
       "Compliance statement for agents that support the
        configuration and monitoring of LMP MIB."
   MODULE -- this module

      MANDATORY-GROUPS    { lmpNodeGroup,
                            lmpControlChannelGroup,
                            lmpLinkPropertyCorrelationGroup,
                            lmpPerfGroup,
                            lmpTeLinkGroup,
                            lmpDataLinkGroup }

      GROUP lmpCcIsNotInterfaceGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           control channels that are not interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning false(1)."

      GROUP lmpCcIsInterfaceGroup
      DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 62]
^L
RFC 4327                     LMP-MIB Module                 January 2006


          "This group is mandatory for devices that support
           control channels that are interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning true(2)."

      GROUP lmpLinkVerificationGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           the link verification procedure."

      GROUP lmpNotificationGroup
      DESCRIPTION
          "This group is optional."

      -- lmpNbrTable

      OBJECT      lmpNbrRowStatus
      SYNTAX      RowStatus { active(1), notInService(2) }
      WRITE-SYNTAX RowStatus { active(1), notInService(2),
                               createAndGo(4), destroy(6) }
      DESCRIPTION
          "Support for notReady(3) and createAndWait(5) is
           not required."

      -- lmpControlChannelTable

      OBJECT      lmpCcRemoteAddressType
      SYNTAX      INTEGER { unknown(0), ipv4(1), ipv6(2) }
      DESCRIPTION
          "Only ipv4(1) and ipv6(2) address types need to be
           supported for non-point-to-point configurations."

      OBJECT      lmpCcRemoteIpAddr
      SYNTAX      InetAddress (SIZE(0|4|16))
      DESCRIPTION
          "The size of the IP address depends on the address type."

      OBJECT      lmpCcRowStatus
      SYNTAX      RowStatus { active(1), notInService(2) }
      WRITE-SYNTAX RowStatus { active(1), notInService(2),
                               createAndGo(4), destroy(6) }
      DESCRIPTION
          "Support for notReady(3) and createAndWait(5) is
           not required."

      OBJECT      lmpCcOperStatus
      SYNTAX      INTEGER { up(1), down(2) }
      DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 63]
^L
RFC 4327                     LMP-MIB Module                 January 2006


          "A value of configSnd(3), configRcv(4), active(5),
           goingDown(6) need not be supported."

      -- lmpTeLinkTable

      OBJECT      lmpTeLinkOperStatus
      SYNTAX      INTEGER { up(1), down(2), degraded(5) }
      DESCRIPTION
          "The testing(3) and init(4) state need not be supported."

      OBJECT      lmpTeLinkRowStatus
      SYNTAX      RowStatus { active(1), notInService(2) }
      WRITE-SYNTAX RowStatus { active(1), notInService(2),
                               createAndGo(4), destroy(6) }
      DESCRIPTION
          "Support for notReady(3) and createAndWait(5) is
           not required."

      -- lmpDataLinkTable

      OBJECT      lmpDataLinkActiveOperStatus
      SYNTAX      INTEGER { upAlloc(1), upFree(2), down(3) }
      DESCRIPTION
          "A value of testing(4) need not be supported."

      OBJECT      lmpDataLinkPassiveOperStatus
      SYNTAX      INTEGER { upAlloc(1), upFree(2), down(3) }
      DESCRIPTION
          "A value of psvTst(4) need not be supported."

      OBJECT      lmpDataLinkRowStatus
      SYNTAX      RowStatus { active(1), notInService(2) }
      WRITE-SYNTAX RowStatus { active(1), notInService(2),
                               createAndGo(4), destroy(6) }
      DESCRIPTION
          "Support for notReady(3) and createAndWait(5) is
           not required."

   ::= { lmpCompliances 1 }

lmpModuleReadOnlyCompliance MODULE-COMPLIANCE
   STATUS current
   DESCRIPTION
       "Compliance statement for agents that support the
        monitoring of the LMP MIB."
   MODULE -- this module

      -- The mandatory groups have to be implemented



Dubuc, et al.               Standards Track                    [Page 64]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      -- by all LMP-enabled devices.  However, they may all be supported
      -- as read-only objects in the case where manual
      -- configuration is not supported.

      MANDATORY-GROUPS    { lmpNodeGroup,
                            lmpControlChannelGroup,
                            lmpLinkPropertyCorrelationGroup,
                            lmpPerfGroup,
                            lmpTeLinkGroup,
                            lmpDataLinkGroup }

      GROUP lmpCcIsNotInterfaceGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           control channels that are not interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning false(1)."

      GROUP lmpCcIsInterfaceGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           control channels that are interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning true(2)."

      GROUP lmpLinkVerificationGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           the link verification procedure."

      GROUP lmpNotificationGroup
      DESCRIPTION
          "This group is optional."

      -- Scalars

      OBJECT      lmpAdminStatus
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpGlobalLinkVerificationInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloIntervalDefault
      MIN-ACCESS  read-only



Dubuc, et al.               Standards Track                    [Page 65]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloIntervalDefaultMin
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloIntervalDefaultMax
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloDeadIntervalDefault
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloDeadIntervalDefaultMin
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloDeadIntervalDefaultMax
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpNotificationMaxRate
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpNbrTable

      OBJECT      lmpNbrRetransmitInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpNbrRetryLimit
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpNbrRetransmitDelta
      MIN-ACCESS  read-only
      DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 66]
^L
RFC 4327                     LMP-MIB Module                 January 2006


          "Write access is not required."

      OBJECT      lmpNbrRowStatus
      SYNTAX      RowStatus { active(1) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required, and active(1) is the
           only status that needs to be supported."

      OBJECT      lmpNbrStorageType
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpControlChannelTable

      OBJECT      lmpCcUnderlyingIfIndex
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcIsIf
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcNbrNodeId
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcRemoteAddressType
      SYNTAX      INTEGER { unknown(0), ipv4(1), ipv6(2) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Only ipv4(1) and ipv6(2) address types need to be
           supported for non-point-to-point configurations."

      OBJECT      lmpCcRemoteIpAddr
      SYNTAX      InetAddress (SIZE(0|4|16))
      MIN-ACCESS  read-only
      DESCRIPTION
          "The size of the IP address depends on the address type."

      OBJECT      lmpCcSetupRole
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."



Dubuc, et al.               Standards Track                    [Page 67]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      OBJECT      lmpCcAuthentication
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloIntervalMin
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloIntervalMax
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloDeadIntervalMin
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcHelloDeadIntervalMax
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpCcRowStatus
      SYNTAX      RowStatus { active(1) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required, and active(1) is the
           only status that needs to be supported."

      OBJECT      lmpCcOperStatus
      SYNTAX      INTEGER { up(1), down(2) }
      DESCRIPTION
          "A value of configSnd(3), configRcv(4), active(5),
           goingDown(6) need not be supported."

      OBJECT      lmpCcStorageType
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpLinkVerificationTable

      OBJECT      lmpLinkVerifyInterval
      MIN-ACCESS  read-only
      DESCRIPTION



Dubuc, et al.               Standards Track                    [Page 68]
^L
RFC 4327                     LMP-MIB Module                 January 2006


          "Write access is not required."

      OBJECT      lmpLinkVerifyDeadInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpLinkVerifyAllLinks
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpTeLinkTable

      OBJECT      lmpTeLinkNbrRemoteNodeId
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required if the link verification
           procedure is enabled."

      OBJECT      lmpTeLinkVerification
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpTeLinkFaultManagement
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpTeLinkDwdm
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpTeLinkOperStatus
      SYNTAX      INTEGER { up(1), down(2), degraded(5) }
      DESCRIPTION
          "The testing(3) and init(4) state need not be supported."

      OBJECT      lmpTeLinkRowStatus
      SYNTAX      RowStatus { active(1) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required, and active(1) is the
           only status that needs to be supported."

      OBJECT      lmpTeLinkStorageType



Dubuc, et al.               Standards Track                    [Page 69]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpTeLinkVerificationTable

      OBJECT      lmpLinkVerifyTransmissionRate
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpLinkVerifyWavelength
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpLinkVerifyRowStatus
      SYNTAX      RowStatus { active(1) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required, and active(1) is the
           only status that needs to be supported."

      OBJECT      lmpLinkVerifyStorageType
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      -- lmpDataLinkTable

      OBJECT      lmpDataLinkAddressType
      SYNTAX      INTEGER { unknown(0), ipv4(1), ipv6(2) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Only ipv4(1) and ipv6(2) address types need to be
           supported for numbered links.  For unnumbered links, the
           unknown(0) address type needs to be supported."

      OBJECT      lmpDataLinkIpAddr
      SYNTAX      InetAddress (SIZE(0|4|16))
      MIN-ACCESS  read-only
      DESCRIPTION
          "Size of data-bearing link IP address depends on type
           of data-bearing link.  Data-bearing link IP address size
           is zero if link is unnumbered, four if link IP address is
           IPv4, and sixteen if link IP address is IPv6."

      OBJECT      lmpDataLinkRemoteIpAddress



Dubuc, et al.               Standards Track                    [Page 70]
^L
RFC 4327                     LMP-MIB Module                 January 2006


      SYNTAX      InetAddress (SIZE(0|4|16))
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required if the link verification
           procedure is enabled."

      OBJECT      lmpDataLinkRemoteIfId
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required if the link verification
           procedure is enabled."

      OBJECT      lmpDataLinkEncodingType
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

      OBJECT      lmpDataLinkActiveOperStatus
      SYNTAX      INTEGER { upAlloc(1), upFree(2), down(3) }
      DESCRIPTION
          "A value of testing(4) need not be supported."

      OBJECT      lmpDataLinkPassiveOperStatus
      SYNTAX      INTEGER { upAlloc(1), upFree(2), down(3) }
      DESCRIPTION
          "A value of psvTst(4) need not be supported."

      OBJECT      lmpDataLinkRowStatus
      SYNTAX      RowStatus { active(1) }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required, and active(1) is the
           only status that needs to be supported."

      OBJECT      lmpDataLinkStorageType
      MIN-ACCESS  read-only
      DESCRIPTION
          "Write access is not required."

   ::= { lmpCompliances 2 }

-- Units of conformance

lmpNodeGroup OBJECT-GROUP
   OBJECTS { lmpAdminStatus,
             lmpOperStatus,
             lmpNbrAdminStatus,
             lmpNbrOperStatus,



Dubuc, et al.               Standards Track                    [Page 71]
^L
RFC 4327                     LMP-MIB Module                 January 2006


             lmpNbrRowStatus,
             lmpNbrStorageType,
             lmpUnprotectedNotificationsEnabled,
             lmpNotificationMaxRate
           }
   STATUS  current
   DESCRIPTION
          "Collection of objects that represent LMP node
           configuration."
   ::= { lmpGroups 1 }

lmpControlChannelGroup OBJECT-GROUP
   OBJECTS {
             lmpNbrRetransmitInterval,
             lmpNbrRetryLimit,
             lmpNbrRetransmitDelta,
             lmpNbrAdminStatus,
             lmpNbrOperStatus,
             lmpNbrRowStatus,
             lmpNbrStorageType,
             lmpCcHelloIntervalDefault,
             lmpCcHelloIntervalDefaultMin,
             lmpCcHelloIntervalDefaultMax,
             lmpCcHelloDeadIntervalDefault,
             lmpCcHelloDeadIntervalDefaultMin,
             lmpCcHelloDeadIntervalDefaultMax,
             lmpCcNbrNodeId,
             lmpCcRemoteId,
             lmpCcRemoteAddressType,
             lmpCcRemoteIpAddr,
             lmpCcSetupRole,
             lmpCcAuthentication,
             lmpCcHelloInterval,
             lmpCcHelloIntervalMin,
             lmpCcHelloIntervalMax,
             lmpCcHelloIntervalNegotiated,
             lmpCcHelloDeadInterval,
             lmpCcHelloDeadIntervalMin,
             lmpCcHelloDeadIntervalMax,
             lmpCcHelloDeadIntervalNegotiated,
             lmpCcOperStatus,
             lmpCcRowStatus,
             lmpCcStorageType,
             lmpCcUpDownNotificationsEnabled
           }
   STATUS  current
   DESCRIPTION
          "Objects that can be used to configure LMP interface."



Dubuc, et al.               Standards Track                    [Page 72]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   ::= { lmpGroups 2 }

lmpCcIsInterfaceGroup OBJECT-GROUP
   OBJECTS { lmpCcIsIf }
   STATUS  current
   DESCRIPTION
          "Objects that can be used to configure control channels
           that are interfaces."
   ::= { lmpGroups 3 }

lmpCcIsNotInterfaceGroup OBJECT-GROUP
   OBJECTS { lmpCcUnderlyingIfIndex,
             lmpCcIsIf,
             lmpCcLastChange,
             lmpCcAdminStatus
           }
   STATUS  current
   DESCRIPTION
          "Objects that can be used to configure control channels
           that are not interfaces."
   ::= { lmpGroups 4 }

lmpLinkPropertyCorrelationGroup OBJECT-GROUP
   OBJECTS { lmpLinkPropertyNotificationsEnabled }
   STATUS  current
   DESCRIPTION
          "Collection of objects used to configure the link
           property correlation procedure."
   ::= { lmpGroups 5 }

lmpLinkVerificationGroup OBJECT-GROUP
   OBJECTS { lmpGlobalLinkVerificationInterval,
             lmpLinkVerifyInterval,
             lmpLinkVerifyDeadInterval,
             lmpLinkVerifyTransportMechanism,
             lmpLinkVerifyAllLinks,
             lmpLinkVerifyTransmissionRate,
             lmpLinkVerifyWavelength,
             lmpLinkVerifyRowStatus,
             lmpLinkVerifyStorageType,
             lmpDataLinkNotificationsEnabled
           }
   STATUS  current
   DESCRIPTION
          "Collection of objects that represent the link
           verification procedure configuration."
   ::= { lmpGroups 6 }




Dubuc, et al.               Standards Track                    [Page 73]
^L
RFC 4327                     LMP-MIB Module                 January 2006


lmpPerfGroup OBJECT-GROUP
   OBJECTS { lmpCcInOctets,
             lmpCcInDiscards,
             lmpCcInErrors,
             lmpCcOutOctets,
             lmpCcOutDiscards,
             lmpCcOutErrors,
             lmpCcConfigReceived,
             lmpCcConfigSent,
             lmpCcConfigRetransmit,
             lmpCcConfigAckReceived,
             lmpCcConfigAckSent,
             lmpCcConfigNackSent,
             lmpCcConfigNackReceived,
             lmpCcHelloReceived,
             lmpCcHelloSent,
             lmpCcBeginVerifyReceived,
             lmpCcBeginVerifySent,
             lmpCcBeginVerifyRetransmit,
             lmpCcBeginVerifyAckReceived,
             lmpCcBeginVerifyAckSent,
             lmpCcBeginVerifyNackReceived,
             lmpCcBeginVerifyNackSent,
             lmpCcEndVerifyReceived,
             lmpCcEndVerifySent,
             lmpCcEndVerifyRetransmit,
             lmpCcEndVerifyAckReceived,
             lmpCcEndVerifyAckSent,
             lmpCcTestStatusSuccessReceived,
             lmpCcTestStatusSuccessSent,
             lmpCcTestStatusSuccessRetransmit,
             lmpCcTestStatusFailureReceived,
             lmpCcTestStatusFailureSent,
             lmpCcTestStatusFailureRetransmit,
             lmpCcTestStatusAckReceived,
             lmpCcTestStatusAckSent,
             lmpCcLinkSummaryReceived,
             lmpCcLinkSummarySent,
             lmpCcLinkSummaryRetransmit,
             lmpCcLinkSummaryAckReceived,
             lmpCcLinkSummaryAckSent,
             lmpCcLinkSummaryNackReceived,
             lmpCcLinkSummaryNackSent,
             lmpCcChannelStatusReceived,
             lmpCcChannelStatusSent,
             lmpCcChannelStatusRetransmit,
             lmpCcChannelStatusAckReceived,
             lmpCcChannelStatusAckSent,



Dubuc, et al.               Standards Track                    [Page 74]
^L
RFC 4327                     LMP-MIB Module                 January 2006


             lmpCcChannelStatusReqReceived,
             lmpCcChannelStatusReqSent,
             lmpCcChannelStatusReqRetransmit,
             lmpCcChannelStatusRspReceived,
             lmpCcChannelStatusRspSent,
             lmpCcCounterDiscontinuityTime,
             lmpTeInOctets,
             lmpTeOutOctets,
             lmpTeBeginVerifyReceived,
             lmpTeBeginVerifySent,
             lmpTeBeginVerifyRetransmit,
             lmpTeBeginVerifyAckReceived,
             lmpTeBeginVerifyAckSent,
             lmpTeBeginVerifyNackReceived,
             lmpTeBeginVerifyNackSent,
             lmpTeEndVerifyReceived,
             lmpTeEndVerifySent,
             lmpTeEndVerifyRetransmit,
             lmpTeEndVerifyAckReceived,
             lmpTeEndVerifyAckSent,
             lmpTeTestStatusSuccessReceived,
             lmpTeTestStatusSuccessSent,
             lmpTeTestStatusSuccessRetransmit,
             lmpTeTestStatusFailureReceived,
             lmpTeTestStatusFailureSent,
             lmpTeTestStatusFailureRetransmit,
             lmpTeTestStatusAckReceived,
             lmpTeTestStatusAckSent,
             lmpTeLinkSummaryReceived,
             lmpTeLinkSummarySent,
             lmpTeLinkSummaryRetransmit,
             lmpTeLinkSummaryAckReceived,
             lmpTeLinkSummaryAckSent,
             lmpTeLinkSummaryNackReceived,
             lmpTeLinkSummaryNackSent,
             lmpTeChannelStatusReceived,
             lmpTeChannelStatusSent,
             lmpTeChannelStatusRetransmit,
             lmpTeChannelStatusAckReceived,
             lmpTeChannelStatusAckSent,
             lmpTeChannelStatusReqReceived,
             lmpTeChannelStatusReqSent,
             lmpTeChannelStatusReqRetransmit,
             lmpTeChannelStatusRspSent,
             lmpTeChannelStatusRspReceived,
             lmpTeCounterDiscontinuityTime,
             lmpDataLinkTestReceived,
             lmpDataLinkTestSent,



Dubuc, et al.               Standards Track                    [Page 75]
^L
RFC 4327                     LMP-MIB Module                 January 2006


             lmpDataLinkActiveTestSuccess,
             lmpDataLinkActiveTestFailure,
             lmpDataLinkPassiveTestSuccess,
             lmpDataLinkPassiveTestFailure,
             lmpDataLinkDiscontinuityTime
           }
   STATUS  current
   DESCRIPTION
          "Collection of objects used to provide performance
           information about LMP interfaces and data-bearing links."
   ::= { lmpGroups 7 }

lmpTeLinkGroup OBJECT-GROUP
   OBJECTS { lmpTeLinkNbrRemoteNodeId,
             lmpTeLinkVerification,
             lmpTeLinkFaultManagement,
             lmpTeLinkDwdm,
             lmpTeLinkOperStatus,
             lmpTeLinkRowStatus,
             lmpTeLinkStorageType,
             lmpTeLinkNotificationsEnabled
           }
   STATUS  current
   DESCRIPTION
          "Objects that can be used to configure TE links."
   ::= { lmpGroups 8 }

lmpDataLinkGroup OBJECT-GROUP
   OBJECTS { lmpDataLinkType,
             lmpDataLinkAddressType,
             lmpDataLinkIpAddr,
             lmpDataLinkRemoteIpAddress,
             lmpDataLinkRemoteIfId,
             lmpDataLinkEncodingType,
             lmpDataLinkActiveOperStatus,
             lmpDataLinkPassiveOperStatus,
             lmpDataLinkRowStatus,
             lmpDataLinkStorageType
           }
   STATUS  current
   DESCRIPTION
          "Collection of objects that represent data-bearing link
           configuration."
   ::= { lmpGroups 9 }

lmpNotificationGroup NOTIFICATION-GROUP
   NOTIFICATIONS { lmpTeLinkPropertyMismatch,
                   lmpDataLinkPropertyMismatch,



Dubuc, et al.               Standards Track                    [Page 76]
^L
RFC 4327                     LMP-MIB Module                 January 2006


                   lmpUnprotected,
                   lmpControlChannelUp,
                   lmpControlChannelDown,
                   lmpTeLinkDegraded,
                   lmpTeLinkNotDegraded,
                   lmpDataLinkVerificationFailure }
   STATUS  current
   DESCRIPTION
          "Set of notifications defined in this module."
   ::= { lmpGroups 10 }

-- End of LMP-MIB
END

10.  Security Considerations

   There are a number of management objects defined in this MIB module
   with a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.  These are the tables and objects and their
   sensitivity/vulnerability:

   -   Unauthorized changes to the lmpNbrTable, lmpControlChannelTable,
       lmpTeLinkTable, and lmpDataLinkTable may disrupt allocation of
       resources in the network.

   Some of the readable objects in this MIB module (i.e., objects with a
   MAX-ACCESS other than not-accessible) may be considered sensitive or
   vulnerable in some network environments.  It is thus important to
   control even GET and/or NOTIFY access to these objects and possibly
   to even encrypt the values of these objects when sending them over
   the network via SNMP.  These are the tables and objects and their
   sensitivity/vulnerability:

   -   The lmpNbrTable exposes network provider's node IP addresses.

   -   lmpControlChannelTable exposes network provider's control
       network.

   -   lmpDataLinkTable exposes network provider's data network.

   SNMP versions prior to SNMPv3 did not include adequate security.
   Even if the network itself is secure (for example by using IPSec),
   even then, there is no control as to who on the secure network is
   allowed to access and GET/SET (read/change/create/delete) the objects
   in this MIB module.



Dubuc, et al.               Standards Track                    [Page 77]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   It is RECOMMENDED that implementers consider the security features as
   provided by the SNMPv3 framework (see [RFC3410], section 8),
   including full support for the SNMPv3 cryptographic mechanisms (for
   authentication and privacy).

   Further, deployment of SNMP versions prior to SNMPv3 is NOT
   RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
   enable cryptographic security.  It is then a customer/operator
   responsibility to ensure that the SNMP entity giving access to an
   instance of this MIB module is properly configured to give access to
   the objects only to those principals (users) that have legitimate
   rights to indeed GET or SET (change/create/delete) them.

11.  Contributors

   Sudheer Dharanikota
   EMail: sudheer@ieee.org

12.  Acknowledgements

   The general structure of this document has been modeled around the
   MPLS Label Switching Router (LSR) MIB [RFC3813].

   The authors wish to thank Dmitry Ryumkin, Baktha Muralidharan and
   George Wang.

13.  IANA Considerations

   Each of the following "IANA Considerations" subsections requested
   IANA for new assignments.  New assignments can only be made via a
   Standards Action as specified in [RFC2434].

13.1.  IANA Considerations for lmp ifType

   The IANA has assigned 227 ifType for LMP interfaces.

13.2.  IANA Considerations for LMP-MIB

   The IANA has assigned { transmission 227 } to the LMP-MIB module
   specified in this document.











Dubuc, et al.               Standards Track                    [Page 78]
^L
RFC 4327                     LMP-MIB Module                 January 2006


14.  References

14.1.  Normative References

   [RFC2119]     Bradner, S., "Key words for use in RFCs to Indicate
                 Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC2434]     Narten, T. and H. Alvestrand, "Guidelines for Writing
                 an IANA Considerations Section in RFCs", BCP 26, RFC
                 2434, October 1998.

   [RFC2578]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Structure of Management Information Version 2
                 (SMIv2)", STD 58, RFC 2578, April 1999.

   [RFC2579]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Textual Conventions for SMIv2", STD 58, RFC 2579,
                 April 1999.

   [RFC2580]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Conformance Statements for SMIv2", STD 58, RFC 2580,
                 April 1999.

   [RFC2863]     McCloghrie, K. and F. Kastenholz, "The Interfaces Group
                 MIB", RFC 2863, June 2000.

   [RFC2914]     Floyd, S., "Congestion Control Principles", BCP 41, RFC
                 2914, September 2000.

   [RFC3471]     Berger, L., "Generalized Multi-Protocol Label Switching
                 (GMPLS) Signaling Functional Description", RFC 3471,
                 January 2003.

   [RFC4001]     Daniele, M., Haberman, B., Routhier, S., and J.
                 Schoenwaelder, "Textual Conventions for Internet
                 Network Addresses", RFC 4001, February 2005.

   [RFC4204]     Lang, J., "Link Management Protocol (LMP)", RFC 4204,
                 October 2005.

   [RFC4207]     Lang, J. and D. Papadimitriou, "Synchronous Optical
                 Network (SONET)/Synchronous Digital Hierarchy (SDH)
                 Encoding for Link Management Protocol (LMP) Test
                 Messages", RFC 4207, October 2005.







Dubuc, et al.               Standards Track                    [Page 79]
^L
RFC 4327                     LMP-MIB Module                 January 2006


   [RFC4209]     Fredette, A., Ed. and J. Lang, Ed., "Link Management
                 Protocol (LMP) for Dense Wavelength Division
                 Multiplexing (DWDM) Optical Line Systems", RFC 4209,
                 October 2005.

   [RFC4220]     Dubuc, M., Nadeau, T., and J. Lang, "Traffic
                 Engineering Link Management Information Base", RFC
                 4220, November 2005.

14.2.  Informative References

   [RFC3410]     Case, J., Mundy, R., Partain, D., and B. Stewart,
                 "Introduction and Applicability Statements for
                 Internet-Standard Management Framework", RFC 3410,
                 December 2002.

   [RFC3813]     Srinivasan, C., Viswanathan, A., and T. Nadeau,
                 "Multiprotocol Label Switching (MPLS) Traffic
                 Engineering (TE) Management Information Base (MIB)",
                 RFC 3812, June 2004.































Dubuc, et al.               Standards Track                    [Page 80]
^L
RFC 4327                     LMP-MIB Module                 January 2006


Authors' Addresses

   Martin Dubuc

   EMail: dubuc.consulting@sympatico.ca


   Thomas D. Nadeau
   Cisco Systems, Inc.
   1414 Massachusetts Ave.
   Boxborough, MA 01719

   EMail: tnadeau@cisco.com


   Jonathan P. Lang
   Sonos, Inc.
   223 E. De La Guerra St.
   Santa Barbara, CA 93101

   EMail: jplang@ieee.org


   Evan McGinnis
   Hammerhead Systems
   640 Clyde Court
   Mountain View, CA 94043

   EMail: emcginnis@hammerheadsystems.com






















Dubuc, et al.               Standards Track                    [Page 81]
^L
RFC 4327                     LMP-MIB Module                 January 2006


Full Copyright Statement

   Copyright (C) The Internet Society (2006).

   This document is subject to the rights, licenses and restrictions
   contained in BCP 78, and except as set forth therein, the authors
   retain all their rights.

   This document and the information contained herein are provided on an
   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   Intellectual Property Rights or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; nor does it represent that it has
   made any independent effort to identify any such rights.  Information
   on the procedures with respect to rights in RFC documents can be
   found in BCP 78 and BCP 79.

   Copies of IPR disclosures made to the IETF Secretariat and any
   assurances of licenses to be made available, or the result of an
   attempt made to obtain a general license or permission for the use of
   such proprietary rights by implementers or users of this
   specification can be obtained from the IETF on-line IPR repository at
   http://www.ietf.org/ipr.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights that may cover technology that may be required to implement
   this standard.  Please address the information to the IETF at
   ietf-ipr@ietf.org.

Acknowledgement

   Funding for the RFC Editor function is provided by the IETF
   Administrative Support Activity (IASA).







Dubuc, et al.               Standards Track                    [Page 82]
^L