summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc4546.txt
blob: dc1dd13dfbc976a1f8db511c16b3b485bc3751e6 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6641
6642
6643
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
6666
6667
6668
6669
6670
6671
6672
6673
6674
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
6708
6709
6710
6711
6712
6713
6714
6715
6716
6717
6718
6719
6720
6721
6722
6723
6724
6725
6726
6727
6728
6729
6730
6731
6732
6733
6734
6735
6736
6737
6738
6739
6740
6741
6742
6743
6744
6745
6746
6747
6748
6749
6750
6751
6752
6753
6754
6755
6756
6757
6758
6759
6760
6761
6762
6763
6764
6765
6766
6767
6768
6769
6770
6771
6772
6773
6774
6775
6776
6777
6778
6779
6780
6781
6782
6783
6784
6785
6786
6787
6788
6789
6790
6791
6792
6793
6794
6795
6796
6797
6798
6799
6800
6801
6802
6803
6804
6805
6806
6807
6808
6809
6810
6811
6812
6813
6814
6815
6816
6817
6818
6819
6820
6821
6822
6823
6824
6825
6826
6827
6828
6829
6830
6831
6832
6833
6834
6835
6836
6837
6838
6839
6840
6841
6842
6843
6844
6845
6846
6847
6848
6849
6850
6851
6852
6853
6854
6855
6856
6857
6858
6859
6860
6861
6862
6863
6864
6865
6866
6867
6868
6869
6870
6871
6872
6873
6874
6875
6876
6877
6878
6879
6880
6881
6882
6883
6884
6885
6886
6887
6888
6889
6890
6891
6892
6893
6894
6895
6896
6897
6898
6899
6900
6901
6902
6903
6904
6905
6906
6907
6908
6909
6910
6911
6912
6913
6914
6915
6916
6917
6918
6919
6920
6921
6922
6923
6924
6925
6926
6927
6928
6929
6930
6931
6932
6933
6934
6935
6936
6937
6938
6939
6940
6941
6942
6943
6944
6945
6946
6947
6948
6949
6950
6951
6952
6953
6954
6955
6956
6957
6958
6959
6960
6961
6962
6963
6964
6965
6966
6967
6968
6969
6970
6971
6972
6973
6974
6975
6976
6977
6978
6979
6980
6981
6982
6983
6984
6985
6986
6987
6988
6989
6990
6991
6992
6993
6994
6995
6996
6997
6998
6999
7000
7001
7002
7003
7004
7005
7006
7007
7008
7009
7010
7011
7012
7013
7014
7015
7016
7017
7018
7019
7020
7021
7022
7023
7024
7025
7026
7027
7028
7029
7030
7031
7032
7033
7034
7035
7036
7037
7038
7039
7040
7041
7042
7043
7044
7045
7046
7047
7048
7049
7050
7051
7052
7053
7054
7055
7056
7057
7058
7059
7060
7061
7062
7063
7064
7065
7066
7067
7068
7069
7070
7071
7072
7073
7074
7075
7076
7077
7078
7079
7080
7081
7082
7083
7084
7085
7086
7087
7088
7089
7090
7091
7092
7093
7094
7095
7096
7097
7098
7099
7100
7101
7102
7103
7104
7105
7106
7107
7108
7109
7110
7111
7112
7113
7114
7115
7116
7117
7118
7119
7120
7121
7122
7123
7124
7125
7126
7127
7128
7129
7130
7131
7132
7133
7134
7135
7136
7137
7138
7139
7140
7141
7142
7143
7144
7145
7146
7147
7148
7149
7150
7151
7152
7153
7154
7155
7156
7157
7158
7159
7160
7161
7162
7163
7164
7165
7166
7167
7168
7169
7170
7171
7172
7173
7174
7175
7176
7177
7178
7179
7180
7181
7182
7183
7184
7185
7186
7187
7188
7189
7190
7191
7192
7193
7194
7195
7196
7197
7198
7199
7200
7201
7202
7203
7204
7205
7206
7207
7208
7209
7210
7211
7212
7213
7214
7215
7216
7217
7218
7219
7220
7221
7222
7223
7224
7225
7226
7227
7228
7229
7230
7231
7232
7233
7234
7235
7236
7237
7238
7239
7240
7241
7242
7243
7244
7245
7246
7247
7248
7249
7250
7251
7252
7253
7254
7255
7256
7257
7258
7259
7260
7261
7262
7263
7264
7265
7266
7267
7268
7269
7270
7271
7272
7273
7274
7275
7276
7277
7278
7279
7280
7281
7282
7283
7284
7285
7286
7287
7288
7289
7290
7291
7292
7293
7294
7295
7296
7297
7298
7299
7300
7301
7302
7303
7304
7305
7306
7307
7308
7309
7310
7311
7312
7313
7314
7315
7316
7317
7318
7319
7320
7321
7322
7323
7324
7325
7326
7327
7328
7329
7330
7331
7332
7333
7334
7335
7336
7337
7338
7339
7340
7341
7342
7343
7344
7345
7346
7347
7348
7349
7350
7351
7352
7353
7354
7355
7356
7357
7358
7359
7360
7361
7362
7363
7364
7365
7366
7367
7368
7369
7370
7371
7372
7373
7374
7375
7376
7377
7378
7379
7380
7381
7382
7383
7384
7385
7386
7387
7388
7389
7390
7391
7392
7393
7394
7395
7396
7397
7398
7399
7400
7401
7402
7403
7404
7405
7406
7407
7408
7409
7410
7411
7412
7413
7414
7415
7416
7417
7418
7419
7420
7421
7422
7423
7424
7425
7426
7427
7428
7429
7430
7431
7432
7433
7434
7435
7436
7437
7438
7439
7440
7441
7442
7443
7444
7445
7446
7447
7448
7449
7450
7451
7452
7453
7454
7455
7456
7457
7458
7459
7460
7461
7462
7463
7464
7465
7466
7467
7468
7469
7470
7471
7472
7473
7474
7475
7476
7477
7478
7479
7480
7481
7482
7483
7484
7485
7486
7487
7488
7489
7490
7491
7492
7493
7494
7495
7496
7497
7498
7499
7500
7501
7502
7503
7504
7505
7506
7507
7508
7509
7510
7511
7512
7513
7514
7515
7516
7517
7518
7519
7520
7521
7522
7523
7524
7525
7526
7527
7528
7529
7530
7531
7532
7533
7534
7535
7536
7537
7538
7539
7540
7541
7542
7543
7544
7545
7546
7547
7548
7549
7550
7551
7552
7553
7554
7555
7556
7557
7558
7559
7560
7561
7562
7563
7564
7565
7566
7567
7568
7569
7570
7571
7572
7573
7574
7575
7576
7577
7578
7579
7580
7581
7582
7583
7584
7585
7586
7587
7588
7589
7590
7591
7592
7593
7594
7595
7596
7597
7598
7599
7600
7601
7602
7603
7604
7605
7606
7607
7608
7609
7610
7611
7612
7613
7614
7615
7616
7617
7618
7619
7620
7621
7622
7623
7624
7625
7626
7627
7628
7629
7630
7631
7632
7633
7634
7635
7636
7637
7638
7639
7640
7641
7642
7643
7644
7645
7646
7647
7648
7649
7650
7651
7652
7653
7654
7655
7656
7657
7658
7659
7660
7661
7662
7663
7664
7665
7666
7667
7668
7669
7670
7671
7672
7673
7674
7675
7676
7677
7678
7679
7680
7681
7682
7683
7684
7685
7686
7687
7688
7689
7690
7691
7692
7693
7694
7695
7696
7697
7698
7699
7700
7701
7702
7703
7704
7705
7706
7707
7708
7709
7710
7711
7712
7713
7714
7715
7716
7717
7718
7719
7720
7721
7722
7723
7724
7725
7726
7727
7728
7729
7730
7731
7732
7733
7734
7735
7736
7737
7738
7739
7740
7741
7742
7743
7744
7745
7746
7747
7748
7749
7750
7751
7752
7753
7754
7755
7756
7757
7758
7759
7760
7761
7762
7763
7764
7765
7766
7767
7768
7769
7770
7771
7772
7773
7774
7775
7776
7777
7778
7779
7780
7781
7782
7783
7784
7785
7786
7787
Network Working Group                                          D. Raftus
Request for Comments: 4546                        ATI Technologies, Inc.
Obsoletes: 2670                                               E. Cardona
Category: Standards Track                                      CableLabs
                                                               June 2006


      Radio Frequency (RF) Interface Management Information Base
   for Data over Cable Service Interface Specifications (DOCSIS) 2.0
                        Compliant RF Interfaces

Status of This Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

   This document revises and obsoletes RFC 2670.  Please see Section 5.3
   for a description of the changes from RFC 2670.

Copyright Notice

   Copyright (C) The Internet Society (2006).

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it defines a set of managed objects for Simple Network
   Management Protocol (SNMP) based management of the Radio Frequency
   (RF) interfaces for systems compliant with the Data Over Cable
   Service Interface Specifications (DOCSIS).

Table of Contents

   1. The Internet-Standard Management Framework ......................2
   2. Glossary ........................................................3
      2.1. Baseline Privacy ...........................................3
      2.2. CATV .......................................................3
      2.3. Channel ....................................................3
      2.4. CM or Cable Modem ..........................................3
      2.5. CMTS or Cable Modem Termination System .....................3
      2.6. Codeword ...................................................4
      2.7. Data Packet ................................................4
      2.8. dBmV .......................................................4
      2.9. DOCSIS .....................................................4



Raftus & Cardona            Standards Track                     [Page 1]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


           2.9.1. DOCSIS 1.0 ..........................................4
           2.9.2. DOCSIS 1.1 ..........................................4
           2.9.3. DOCSIS 2.0 ..........................................4
      2.10. Downstream ................................................5
      2.11. Euro-DOCSIS ...............................................5
      2.12. Head-end ..................................................5
      2.13. MAC Packet ................................................5
      2.14. MCNS ......................................................5
      2.15. Mini-slot .................................................5
      2.16. QPSK (Quadrature Phase Shift Keying) ......................5
      2.17. QAM (Quadrature Amplitude Modulation) .....................5
      2.18. RF ........................................................5
      2.19. Symbol-times ..............................................5
      2.20. Upstream ..................................................6
   3. Overview ........................................................6
      3.1. Textual Conventions ........................................6
           3.1.1. Textual Conventions in RFC 2670 .....................6
           3.1.2. Textual Conventions in RFC 4546 .....................6
      3.2. Structure of the MIB .......................................6
           3.2.1. docsIfBaseObjects ...................................7
           3.2.2. docsIfCmObjects .....................................7
           3.2.3. docsIfCmtsObjects ...................................8
           3.2.4. Relationship to the Interfaces MIB Module ...........8
           3.2.5. Offline Upstream Parameters Handling ...............22
   4. Definitions ....................................................24
   5. Revision History ..............................................134
      5.1. Scope ....................................................134
      5.2. Extension ................................................134
   6. Security Considerations .......................................134
   7. Management Interoperability of DOCSIS 1.0, 1.1, and 2.0 .......136
   8. References ....................................................136
      8.1. Normative References .....................................136
      8.2. Informative References ...................................137

1.  The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] STD 58, RFC 2580
   [RFC2580].



Raftus & Cardona            Standards Track                     [Page 2]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


2.  Glossary

   The terms in this document are derived either from normal cable
   system usage, or from the documents associated with the Data Over
   Cable Service Interface Specification process.

2.1.  Baseline Privacy

   Security interface specification, designed for DOCSIS-compliant cable
   data systems, that ensures device authentication data confidentiality
   in the CATV plant.  See [BPI] and [BPIPLUS].

2.2.  CATV

   Originally "Community Antenna Television", it now refers to any cable
   or hybrid fiber and cable system used to deliver video signals to a
   community.

2.3.  Channel

   A specific frequency allocation with an RF medium, specified by
   channel width in Hertz (cycles per second) and by center frequency.
   Within the US Cable Systems, upstream channels are generally
   allocated from the 5-42MHz range while downstream channels are
   generally allocated from the 50-750MHz range, depending on the
   capabilities of the given system.  The typical broadcast channel
   width in the US is 6MHz.  Upstream channel widths for DOCSIS vary.

   For European cable systems, upstream channels vary by country.  The
   upper edge of upstream channel allocations varies between 25 MHz to
   65 MHz, and the lower edge of downstream channel allocations varies
   between 47 MHz and 87.5 MHz.  The typical broadcast channel width in
   Europe is 8MHz.  The actual parameters are of concern to systems
   deploying Euro-DOCSIS technology.

   The downstream channels conform to the requirements of ITU-T
   Recommendation J.83 [ITU-T_J.83]

2.4.  CM or Cable Modem

   A CM acts as a "slave" station in a DOCSIS-compliant cable data
   system.

2.5.  CMTS or Cable Modem Termination System

   A generic term covering a cable bridge or cable router in a head-end.
   A CMTS acts as the master station in a DOCSIS-compliant cable data
   system.  It is the only station that transmits downstream, and it



Raftus & Cardona            Standards Track                     [Page 3]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   controls the scheduling of upstream transmissions by its associated
   CMs.

2.6.  Codeword

   A characteristic of the Forward Error Correction scheme, used above
   the RF media layer.

   See "Data-Over-Cable Service Interface Specifications: Radio
   Frequency Interface Specification SP-RFIv2.0-I10-051209".

2.7.  Data Packet

   The payload portion of the MAC Packet.

2.8.  dBmV

   A measure of RF signal voltage amplitude, whose power level is
   determined by the characteristic impedance.  A zero dB signal power
   is equivalent to 48.75 dBmV signal amplitude in a 75 Ohm system.

2.9.  DOCSIS

   "Data Over Cable Service Interface Specification".  A term referring
   to the ITU-T J112 [ITU-T_J.112] Annex B standard for cable modem
   systems.

2.9.1.  DOCSIS 1.0

   Cable modem systems that are CM/CMTS compliant to requirements in
   [RFI1.0].  A common reference to DOCSIS 1.0 in this document is the
   upstream channel queuing mechanism, known as Class of Service (COS).

2.9.2.  DOCSIS 1.1

   Cable modem systems that are CM/CMTS compliant to requirements in
   [ITU-T_J.112].  DOCSIS 1.1 references in this document are in part
   associated with the upstream and downstream Quality of Service (QOS).
   The term DOCSIS 1.x is used in this document to refer to both DOCSIS
   1.0 and DOCSIS 1.1.

2.9.3.  DOCSIS 2.0

   Cable modem systems that are CM/CMTS compliant to requirements in
   [ITU-T_J.122].  DOCSIS 2.0 corresponds to the second generation of
   radio-frequency interface specifications of DOCSIS.





Raftus & Cardona            Standards Track                     [Page 4]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


2.10.  Downstream

   The direction from the head-end towards the subscriber.

2.11.  Euro-DOCSIS

   Cable modem systems CM/CMTS that conform to the European spectrum
   lineup and are compliant to requirements of Annex F in [ITU-T_J.122].

2.12.  Head-end

   The origination point in most cable systems of the subscriber video
   signals.  Generally also the location of the CMTS equipment.

2.13.  MAC Packet

   A DOCSIS PDU.

2.14.  MCNS

   "Multimedia Cable Network System".  Generally replaced in usage by
   DOCSIS.

2.15.  Mini-slot

   In general, an interval of time that is allocated by the CMTS to a
   given CM for that CM to transmit in an upstream direction.  See
   [ITU-T_J.122]

2.16.  QPSK (Quadrature Phase Shift Keying)

   A particular modulation scheme on an RF medium.  See [Proakis00].

2.17.  QAM (Quadrature Amplitude Modulation)

   A particular modulation scheme on RF medium.  Usually expressed with
   a number indicating the size of the modulation constellation (e.g.,
   16 QAM).  See [Proakis00].

2.18.  RF

   Radio Frequency.

2.19.  Symbol-times

   A characteristic of the RF modulation scheme.  See [ITU-T_J.122].





Raftus & Cardona            Standards Track                     [Page 5]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


2.20.  Upstream

   The direction from the subscriber towards the head-end.

3.  Overview

   This MIB module provides a set of objects required for the management
   of DOCSIS-compliant Cable Modem (CM) and Cable Modem Termination
   System (CMTS) RF interfaces.  The specification is derived in part
   from the parameters and protocols described in [ITU-T_J.122].

   In this document, the key words "MUST", "MUST NOT", "REQUIRED",
   "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY",
   and "OPTIONAL" are to be interpreted as described in [RFC2119].

3.1.  Textual Conventions

   This MIB module defines new textual conventions for CM and CMTS
   indications of DOCSIS 2.0 RFI capabilities, configuration, usage, and
   backward compatible modes of operation, as defined in [RFI2.0].  With
   the same purpose, there are some textual conventions that represent
   capabilities and modes of operation of [RFI1.1] that are not covered
   by RFC 2670, and are managed proprietarily in the DOCSIS OSSI 1.1
   specification [OSSI1.1].

3.1.1.  Textual Conventions in RFC 2670

   RFC 2670 defined two textual conventions, TenthdBmV and TenthdB,
   which are power measurement representations.

3.1.2.  Textual Conventions in RFC 4546

   This MIB module defines the textual convention DocsisUpstreamType to
   represent the DOCSIS 1.0 [RFI1.0] and DOCSIS 2.0 [RFI2.0] upstream
   burst modulation profiles types.

   This MIB module defines the textual conventions DocsisVersion and
   DocsisQosVersion to represent the DOCSIS 1.0 [RFI1.0] and DOCSIS 1.1
   [RFI1.1] COS/QOS capabilities and modes of operation.

3.2.  Structure of the MIB

   This MIB module is structured as three groups:

   o  Management information pertinent to both Cable Modem (CM) and
      Cable Modem Termination System (CMTS) (docsIfBaseObjects).





Raftus & Cardona            Standards Track                     [Page 6]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   o  Management information pertinent to Cable Modem only
      (docsIfCmObjects).

   o  Management information pertinent to Cable Modem Termination System
      only (docsIfCmtsObjects).

   Tables within each of these groups cover different functions; e.g.,
   upstream queue services, channel characteristics, MAC layer
   management, etc.  Rows created automatically (e.g., by the device
   according to the hardware configuration) may and generally will have
   a mixture of configuration and status objects within them.  Rows that
   are meant to be created by the management station are generally
   restricted to configuration (read-create) objects.

3.2.1.  docsIfBaseObjects

   docsIfDownstreamChannelTable - This table describes the existing
   downstream channels for a CMTS and the received downstream channel
   for a CM.

   docsIfUpstreamChannelTable - This table describes the existing
   upstream channels for a CMTS and the current upstream transmission
   channel for a CM.

   docsIfQosProfileTable - This table describes the valid Quality of
   Service profiles for the cable data system.

   docsIfSignalQualityTable - This table is used to monitor RF signal
   quality characteristics of received signals.

   docsIfDocsisBaseCapability - This object is used to indicate the
   highest level of DOCSIS version a cable device can support.

3.2.2.  docsIfCmObjects

   docsIfCmMacTable - This table is used to monitor the DOCSIS MAC
   interface and can be considered an extension to the ifEntry.

   docsIfCmStatusTable - This table maintains a number of status objects
   and counters for cable modems.  There is a comparable table at the
   CMTS, docsIfCmtsCmStatusTable, which maintains similar counters from
   the CMTS point of view.

   docsIfCmServiceTable - This table describes the upstream service
   queues available at this CM.  There is a comparable table at the
   CMTS, docsIfCmtsServiceEntry, which describes the service queues from
   the point of view of the CMTS.




Raftus & Cardona            Standards Track                     [Page 7]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.3.  docsIfCmtsObjects

   docsIfCmtsMacTable - Describes the attributes of each CMTS MAC
   interface.

   docsIfCmtsStatusTable - This table provides a set of aggregated
   counters that roll-up values and events that occur on the underlying
   sub-interfaces.

   docsIfCmtsCmStatusTable - This table is used to hold information
   about known (i.e., ranging, registered, and/or previously online)
   cable modems on the system serviced by this CMTS.

   docsIfCmtsServiceTable - This table provides access to the
   information related to upstream service queues.

   docsIfCmtsModulationTable - This table allows control over the
   modulation profiles for RF channels associated with this CMTS.

   docsIfCmtsMacToCmTable - This table allows fast access into the
   docsIfCmtsCmTable via a MAC address (of the CM) interface.

   docsIfCmtsChannelUtilizationTable - This table provides statistical
   load usage data for attached upstream and downstream physical
   channels.

   docsIfCmtsDownChannelCounterTable - This table provides statistical
   data for attached downstream channels, appropriate as input for load
   usage calculations.

   docsIfCmtsUpChannelCounterTable - This table provides statistical
   data for attached upstream channels, appropriate as input for load
   usage calculations.

3.2.4.  Relationship to the Interfaces MIB Module

   This section clarifies the relationship of this MIB module to the
   Interfaces MIB [RFC2863].  Several areas of correlation are addressed
   in the following subsections.  The implementer is referred to the
   Interfaces MIB document in order to understand the general intent of
   these areas.

3.2.4.1.  Layering Model

   An instance of ifEntry exists for each RF downstream interface, for
   each RF upstream interface, for each upstream logical Channel, and
   for each RF MAC layer.




Raftus & Cardona            Standards Track                     [Page 8]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   The ifStackTable [RFC2863] MUST be implemented to identify the
   relationships among sub-interfaces.

   The following example illustrates a CMTS MAC interface with one
   downstream and two upstream interfaces.

                                 | <== to network layer
           +------------------ --+-------------------------------+
           |                     RF MAC                          |
           +--+------------------+------------------------+------+
              |                  |                        |
      +-------+-----+     +------+------+          +------+------+
      | Downstream1 |     |  Upstream1  |          |  Upstream2  |
      |             |     |             |          |             |
      +-------------+     ++-----------++          ++-----------++
                           |           |            |           |
                      +----+----+ +----+----+  +----+----+ +----+----+
                      |  Ch-1   | |  Ch-2   |  |  Ch-1   | |  Ch-2   |
                      |(A/TDMA) | |(S-CDMA) |  |(A/TDMA) | |(S-CDMA) |
                      +---------+ +---------+  +---------+ +---------+

                                 Figure 1

   As can be seen from this example, the RF MAC interface is layered on
   top of the downstream and upstream interfaces, and the RF upstream
   interface is layered on top of an upstream logical channel.

   In this example, the assignment of index values could be as follows:

      ifIndex       ifType                     Description

         2    docsCableMaclayer(127)           CATV MAC Layer
         3    docsCableDownstream(128)         CATV Downstream interface
         4    docsCableUpstream(129)           CATV Upstream interface
         5    docsCableUpstream(129)           CATV Upstream interface
         6    docsCableUpstreamChannel(205)    CATV Upstream Channel
         7    docsCableUpstreamChannel(205)    CATV Upstream Channel
         8    docsCableUpstreamChannel(205)    CATV Upstream Channel
         9    docsCableUpstreamChannel(205)    CATV Upstream Channel

                                 Figure 2










Raftus & Cardona            Standards Track                     [Page 9]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   The corresponding ifStack entries would then be:

              | IfStackHigherLayer | ifStackLowerLayer |
              |         0          |         2         |
              |         2          |         3         |
              |         2          |         4         |
              |         2          |         5         |
              |         4          |         6         |
              |         4          |         7         |
              |         5          |         8         |
              |         5          |         9         |
              |         3          |         0         |
              |         6          |         0         |
              |         7          |         0         |
              |         8          |         0         |
              |         9          |         0         |

                                 Figure 3

   The same interface model can also be used in Telephony or Telco
   Return systems.  A pure Telco Return system (Cable Modem, as well as
   Cable Modem Termination System) would not have upstream cable
   channels, only downstream cable channels.  Systems supporting both
   Telco Return and cable upstream channels can use the above model
   without modification.

   Telco Return upstream channel(s) management is outside the scope of
   this document.

3.2.4.2.  Virtual Circuits

   This medium does not support virtual circuits, and this area is not
   applicable to this MIB module.

3.2.4.3.  ifTestTable

   The ifTestTable is optional for DOCSIS CM/CMTS implementations, but
   is not specifically influenced by the RF MIB.

3.2.4.4.  ifRcvAddressTable

   The ifRcvAddressTable is optional for DOCSIS CM/CMTS implementations,
   but is not specifically influenced by the RF MIB.








Raftus & Cardona            Standards Track                    [Page 10]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.4.5.  ifEntry

   This section documents only the differences from the requirements
   specified in the Interfaces MIB module.  See that MIB module for
   columns omitted from the descriptions below.

3.2.4.5.1.  ifEntry for Downstream Interfaces

   The ifEntry for downstream interfaces supports the
   ifGeneralInformationGroup and the ifPacketGroup of the Interfaces MIB
   module.  This is an output-only interface at the CMTS, and all input
   status counters -- ifIn* -- will return zero.  This is an input-only
   interface at the CM, and all output status counters -- ifOut* -- will
   return zero.

3.2.4.5.1.1.  ifEntry for Downstream Interfaces in Cable Modem
              Termination System

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each CATV Downstream interface is represented
                     by an ifEntry.

   ifType            The IANA value of docsCableDownstream(128).

   ifSpeed           Return the speed of this downstream channel.
                     The returned value is the raw bandwidth in bits/s
                     of this interface.  This is the symbol rate
                     multiplied with the number of bits per symbol.

   ifHighSpeed       Return the speed of this downstream channel.
                     The returned value is the raw bandwidth in
                     megabits/s of this interface.  This is the symbol
                     rate multiplied with the number of bits per
                     symbol.

   ifPhysAddress     Return the zero-length OCTET STRING.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of this interface.

   ifMtu             The size of the largest frame that can be
                     sent on this interface, specified in octets.
                     The value includes the length of the MAC header.

   ifInOctets
   ifHCInOctets      Return zero.



Raftus & Cardona            Standards Track                    [Page 11]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifInUcastPkts
   ifHCInUcastPkts   Return zero.

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return zero.

   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return zero.

   ifInDiscards      Return zero.

   ifInErrors        Return zero.

   ifInUnknownProtos Return zero.

   ifOutOctets
   ifHCOutOctets     The total number of octets transmitted on this
                     interface.  This includes MAC packets as well as
                     data packets, and includes the length of the MAC
                     header.
   ifOutUcastPkts
   ifHCOutUcastPkts  The number of unicast packets transmitted on this
                     interface.  This includes MAC packets as well as
                     data packets.

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return the number of multicast packets
                     transmitted on this interface.
                     This includes MAC packets as well as data
                     packets.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return the number of broadcast packets transmitted
                     on this interface.  This includes MAC packets as
                     well as data packets.

   ifOutDiscards     The total number of outbound packets which
                     were discarded.  Possible reasons are:
                     buffer shortage.

   ifOutErrors       The number of packets that could not be
                     transmitted due to errors.

   ifPromiscuousMode Return false.



Raftus & Cardona            Standards Track                    [Page 12]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.4.5.1.2.  ifEntry for Downstream Interfaces in Cable Modem

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each CATV Downstream interface is represented
                     by an ifEntry.


   ifType            The IANA value of docsCableDownstream(128).

   ifSpeed           Return the speed of this downstream channel.
                     The returned value the raw bandwidth in bits/s
                     of this interface.  This is the symbol rate
                     multiplied with the number of bits per symbol.

   ifHighSpeed       Return the speed of this downstream channel.
                     The returned value the raw bandwidth in megabits/s
                     of this interface.  This is the symbol rate
                     multiplied with the number of bits per symbol.

   ifPhysAddress     Return the zero-length OCTET STRING.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of this interface.

   ifMtu             The size of the largest frame that can be
                     received from this interface, specified in octets.
                     The value includes the length of the MAC header.

   ifInOctets
   ifHCInOctets      The total number of octets received on this
                     interface.  This includes data packets as well as
                     MAC packets, and includes the length of the
                     MAC header.

   ifInUcastPkts
   ifHCInUcastPkts   The number of unicast packets received on this
                     interface.  This includes data packets as well as
                     MAC packets.

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return the number of multicast packets received
                     on this interface.  This includes data packets as
                     well as MAC packets.





Raftus & Cardona            Standards Track                    [Page 13]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return the number of broadcast packets received
                     on this interface.  This includes data packets
                     as well as MAC packets.

   ifInDiscards      The total number of received packets that have
                     been discarded.
                     The possible reasons are: buffer shortage.

   ifInErrors        The number of inbound packets that contained
                     errors preventing them from being deliverable
                     to higher layers.
                     Possible reasons are: MAC FCS error.

   ifInUnknownProtos The number of frames with an unknown packet type.
                     These are MAC frames with an unknown packet type.

   ifOutOctets       Return zero.
   ifHCOutOctets

   ifOutUcastPkts    Return zero.
   ifHCOutUcastPkts

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return zero.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return zero.

   ifOutDiscards     Return zero.

   ifOutErrors       Return zero.

   ifPromiscuousMode Refer to the Interfaces MIB.

3.2.4.5.2.  ifEntry for Upstream Interfaces

   Each supported interface of the type docsCableUpstream(129) must have
   a corresponding ifEntry.  The ifEntry for upstream interfaces
   supports the ifGeneralInformationGroup and the ifPacketGroup of the
   Interfaces MIB.  This is an input-only interface at the CMTS, and all
   output status counters -- ifOut* -- will return zero.  This is an
   output only interface at the CM, and all input status counters --
   ifIn* -- will return zero.




Raftus & Cardona            Standards Track                    [Page 14]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.4.5.2.1.  ifEntry for Upstream Interfaces in Cable Modem Termination
              System

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each RF Cable Upstream interface is represented
                     by an ifEntry.

   ifType            The IANA value of docsCableUpstream (129).

   ifSpeed           Return the maximum channel throughput (not payload
                     throughput) supported by the interface.
                     The maximum throughput is calculated for the case
                     where upstream channels are configured to maximize
                     interface throughput.

   ifHighSpeed       Return the maximum channel throughput (not payload
                     throughput) supported by the interface.
                     The maximum throughput is calculated for the case
                     where upstream channels are configured to maximize
                     interface throughput.  Units for this object are
                     (1/1 000 000) * IfSpeed.

   ifPhysAddress     Return the zero-length OCTET STRING.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of this interface.
                     This reflects the total status of all the channels
                     under this interface.  So if at least one channel
                     has a physical connection this interface has
                     connection.

   ifMtu             The size of the largest frame that can be
                     transmitted on this interface, specified in
                     octets.  The value includes the length of the MAC
                     header.  This is the maximum of all the ifMtu of
                     all the channels under this interface.

   ifInOctets
   ifHCInOctets      The total (sum) number of octets received on all
                     the upstream channels under this
                     interface.  This includes data packets as well as
                     MAC packets, and includes the length of the
                     MAC header.






Raftus & Cardona            Standards Track                    [Page 15]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifInUcastPkts
   ifHCInUcastPkts   The total number of unicast packets received on
                     all the upstream channels under this
                     interface.  This includes data packets as well as
                     MAC packets.

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return the total number of multicast packets
                     received on all the upstream channels under this
                     interface.  This includes data packets as well as
                     MAC layer packets.

   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return the total number of broadcast packets
                     received on all the upstream channels under this
                     interface.  This includes data packets as well as
                     MAC packets.

   ifInDiscards      The total number of received packets that have
                     been discarded on all the upstream channels under
                     this interface.
                     The possible reasons are: buffer shortage.

   ifInErrors        The total number of inbound packets that contained
                     errors preventing them from being deliverable
                     to higher layers.
                     Possible reasons are: MAC FCS error.

   ifInUnknownProtos The total number of frames with an unknown packet
                     type.  These are MAC frames with an unknown packet
                     type.

   ifOutOctets       Return zero.
   ifHCOutOctets

   ifOutUcastPkts    Return zero.
   ifHCOutOctets

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return zero.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return zero.




Raftus & Cardona            Standards Track                    [Page 16]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifOutDiscards     Return zero.

   ifOutErrors       Return zero.

3.2.4.5.2.2.  ifEntry for Upstream Interfaces in Cable Modem

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each RF Cable Upstream interface is represented
                     by an ifEntry.

   ifType            The IANA value of docsCableUpstream (129).

   ifSpeed           Return the speed of this upstream interface.
                     The returned value is the raw bandwidth
                     in bits/s of this interface.

   ifHighSpeed       Return the speed of this upstream interface.
                     The returned value is the raw bandwidth
                     in megabits/s of this interface.

   ifPhysAddress     Return the zero-length OCTET STRING.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of this interface.

   ifMtu             The size of the largest frame that can be
                     transmitted on this interface, specified in
                     octets.  The value includes the length of the MAC
                     header.

   ifInOctets        Return zero.
   ifHCInOctets

   ifInUcastPkts     Return zero.
   ifHCInUcastPkts

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return zero.

   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return zero.

   ifInDiscards      Return zero.




Raftus & Cardona            Standards Track                    [Page 17]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifInErrors        Return zero.

   ifInUnknownProtos Return zero.

   ifOutOctets
   ifHCOutOctets     The total number of octets transmitted on this
                     interface.  This includes MAC packets as well as
                     data packets, and includes the length of the MAC
                     header.

   ifOutUcastPkts
   ifHCOutUcastPkts  The number of unicast packets transmitted on this
                     interface.  This includes MAC packets as well as
                     data packets.

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return the number of multicast packets transmitted
                     on this interface.
                     This includes MAC packets as well as data packets.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return the number of broadcast packets transmitted
                     on this interface.
                     This includes MAC packets as well as data packets.

   ifOutDiscards     The total number of outbound packets that
                     were discarded.  Possible reasons are:
                     buffer shortage.

   ifOutErrors       The number of packets that could not be
                     transmitted due to errors.

   ifPromiscuousMode Return false.

3.2.4.5.3.  ifEntry for Upstream Channels

   Each supported channel of the type docsCableUpstreamChannel(205) must
   have a corresponding ifEntry.

   The ifEntry for upstream channels supports the
   ifGeneralInformationGroup and the ifPacketGroup of the Interfaces
   MIB.  This is an input only interface at the CMTS and all output
   status counters -- ifOut* -- will return zero.  DOCSIS CMs are not
   required to support logical upstream channels.





Raftus & Cardona            Standards Track                    [Page 18]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.4.5.3.1.  ifEntry for Upstream Channels in Cable Modem Termination
              System

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each RF Cable Upstream channel is represented
                     by an ifEntry.

   ifType            The IANA value of docsCableUpstreamChannel (205).

   ifSpeed           Return the speed of this upstream channel.
                     The returned value is the raw bandwidth
                     in bits/s of this channel.

   ifHighSpeed       Return the speed of this upstream channel.
                     The returned value is the raw bandwidth
                     in megabits/s of this channel.

   ifPhysAddress     Return the zero-length OCTET STRING.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of this interface.

   ifMtu             The size of the largest frame that can be
                     received on this interface, specified in octets.
                     The value includes the length of the MAC header.

   ifInOctets        The total number of octets received on this
                     interface.  This includes data packets as well as
                     MAC packets, and includes the length of the
                     MAC header.

   ifInUcastPkts
   ifHCInUcastPkts
                     The number of unicast packets received on this
                     interface.  This includes data packets as well as
                     MAC packets.

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return the number of multicast packets received
                     on this interface.  This includes data packets as
                     well as MAC layer packets.







Raftus & Cardona            Standards Track                    [Page 19]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return the number of broadcast packets received
                     on this interface.  This includes data packets
                     as well as MAC packets.

   ifInDiscards      The total number of received packets that have
                     been discarded.
                     The possible reasons are: buffer shortage.

   ifInErrors        The number of inbound packets that contained
                     errors preventing them from being deliverable
                     to higher layers.
                     Possible reasons are: MAC FCS error.

   ifInUnknownProtos The number of frames with an unknown packet type.
                     These are MAC frames with an unknown packet type.

   ifOutOctets       Return zero.
   ifHCOutOctets

   ifOutUcastPkts    Return zero.
   ifHCOutUcastPkts

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return zero.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return zero.

   ifOutDiscards     Return zero.

   ifOutErrors       Return zero.

3.2.4.5.4.  ifEntry for the MAC Layer

   The ifEntry for the MAC Layer supports the ifGeneralInformationGroup
   and the ifPacketGroup of the Interfaces MIB.  This interface provides
   an aggregate view of status for the lower level downstream and
   upstream interfaces.

   ifTable           Comments
   ==============    ===========================================
   ifIndex           Each RF Cable MAC layer entity is represented
                     by an ifEntry.




Raftus & Cardona            Standards Track                    [Page 20]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifType            The IANA value of docsCableMaclayer(127).

   ifSpeed           Return zero.

   ifPhysAddress     Return the physical address of this interface.

   ifAdminStatus     The administrative status of this interface.

   ifOperStatus      The current operational status of the MAC
                     layer interface.

   ifHighSpeed       Return zero.

   ifMtu             Return 1500.

   ifInOctets
   ifHCInOctets      The total number of data octets received on this
                     interface, targeted for upper protocol layers.

   ifInUcastPkts
   ifHCInUcastPkts   The number of unicast packets received on this
                     interface, targeted for upper protocol layers.

   ifInMulticastPkts
   ifHCInMulticastPkts
                     Return the number of multicast packets received
                     on this interface, targeted for upper protocol
                     layers.

   ifInBroadcastPkts
   ifHCInBroadcastPkts
                     Return the number of broadcast packets received
                     on this interface, targeted for upper protocol
                     layers.

   ifInDiscards      The total number of received packets that have
                     been discarded.
                     The possible reasons are: buffer shortage.

   ifInErrors        The number of inbound packets that contained
                     errors preventing them from being deliverable
                     to higher layers.
                     Possible reasons are: data packet FCS error,
                     invalid MAC header.

   ifInUnknownProtos The number of frames with an unknown packet type.
                     This is the number of data packets targeted for
                     upper protocol layers with an unknown packet type.



Raftus & Cardona            Standards Track                    [Page 21]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   ifOutOctets       The total number of octets, received from upper
   ifHCOutOctets     protocol layers and transmitted on this interface.

   ifOutUcastPkts
   ifHCOutUcastPkts  The number of unicast packets, received from upper
                     protocol layers and transmitted on this interface.

   ifOutMulticastPkts
   ifHCOutMulticastPkts
                     Return the number of multicast packets received
                     from upper protocol layers and transmitted on this
                     interface.

   ifOutBroadcastPkts
   ifHCOutBroadcastPkts
                     Return the number of broadcast packets received
                     from upper protocol layers and transmitted on this
                     interface.

   ifOutDiscards     The total number of outbound packets that
                     were discarded.  Possible reasons are:
                     buffer shortage.

   ifOutErrors       The number of packets that could not be
                     transmitted due to errors.

   ifPromiscuousMode Refer to the Interfaces MIB.

3.2.5.  Offline Upstream Parameters Handling

3.2.5.1.  Overview

   This section describes the offline configuration of the DOCSIS 2.0
   upstream logical interface parameters.  The purpose of this feature
   is to guarantee that upstream logical interface parameters (such as
   modulation profile, channel type, mini-slot size, and SCDMA
   attributes) are consistent prior to committing changes to an active
   upstream logical interface.  This mechanism can reduce possible
   downtime of the upstream interface by minimizing SNMP SET operations
   to in-service upstream interfaces.  This mechanism is supported by
   CMTSs and is not applicable to CMs.

3.2.5.2.  Operation

   This mechanism uses three upstream channel MIB objects defined for
   DOCSIS 2.0 CMTS implementations:





Raftus & Cardona            Standards Track                    [Page 22]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfUpChannelStatus - The RowStatus object for the creation of
   temporary interfaces in the upstream interface table.  A temporary
   entry is used to modify, validate, and commit upstream parameters of
   a physical interface.  In the CMTS, a physical upstream interface
   refers to an upstream logical channel interface.

   docsIfUpChannelCloneFrom - This MIB object associates a physical
   interface with a temporary interface for the purpose of updating the
   upstream parameters of the physical interface.

   docsIfUpChannelUpdate - This MIB object is the commit object that
   transfers the validated upstream parameters from the temporary
   interface to the physical interface.

   The offline upstream parameters handling operation is as follows:

   o  A temporary interface is created in which docsIfUpChannelStatus is
      set to 'createAndWait', which turns the new create entry status to
      'notReady'.

   o  A SET to docsIfUpChannelCloneFrom in the temporary interface to
      the physical interface ifIndex value performs two actions:

      *  Creates the association of the physical interface to the
         temporary interface.

      *  Copies the original upstream parameters from the physical
         interface to the temporary interface, which turns its status to
         'notInService'.

   o  The operator modifies the temporary interface parameters to the
      desired values.

   o  At this point, a SET to 'active' to the RowStatus of the temporary
      interface is successful if all parameters in the temporary
      interface are valid for the associated physical interface;
      otherwise, the temporary entry remains with status 'notInservice',
      and the SET returns the error 'commitFailed'.

   o  When the temporary interface status is 'active', a SET to
      docsIfUpChannelUpdate to 'true' transfers the temporary interface
      parameters values to the physical interface.

   o  After completion of the update operations, the temporary interface
      is destroyed, setting the docsIfUpChannelStatus to 'destroy'.






Raftus & Cardona            Standards Track                    [Page 23]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


3.2.5.3.  Relation of docsIfUpChannelStatus and ifMib

   The main purpose of docsIfUpChannelStatus is the creation of
   temporary interfaces for offline handling of the configuration of
   physical interfaces; it does not manage the creation or control of
   physical interfaces.  To maintain a consistent operation and status
   report of interfaces, this object does not manage the administrative
   and operational status of physical interfaces.

4.  Definitions

   DOCS-IF-MIB DEFINITIONS ::= BEGIN

     IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        Unsigned32,
        Integer32,
        Counter32,
        Counter64,
        TimeTicks,
        IpAddress,
        transmission
                FROM SNMPv2-SMI        -- [RFC2578]
        TEXTUAL-CONVENTION,
        MacAddress,
        RowStatus,
        TruthValue,
        TimeInterval,
        TimeStamp,
        StorageType
                FROM SNMPv2-TC         -- [RFC2579]
        OBJECT-GROUP,

        MODULE-COMPLIANCE
                FROM SNMPv2-CONF       -- [RFC2580]
        ifIndex, InterfaceIndexOrZero
                FROM IF-MIB            -- [RFC2863]
        InetAddressType,
        InetAddress
                FROM INET-ADDRESS-MIB  -- [RFC4001]
        IANAifType
                FROM IANAifType-MIB;   -- [IANA]

   docsIfMib MODULE-IDENTITY
        LAST-UPDATED    "200605240000Z" -- May 24, 2006
        ORGANIZATION    "IETF IPCDN Working Group"
        CONTACT-INFO



Raftus & Cardona            Standards Track                    [Page 24]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "        David Raftus
             Postal: ATI Technologies Inc.
                     340 Terry Fox Drive, Suite 202
                     Ottawa Ontario
                     Canada
             Phone:  +1 613 592 1052 ext.222
             E-mail: david.raftus@ati.com

                     Eduardo Cardona
             Postal: Cable Television Laboratories, Inc.
                     858 Coal Creek Circle
                     Louisville, CO 80027-9750
                     U.S.A.
             Phone:  Tel:    +1 303 661 9100
                     Fax:    +1 303 661 9199
             E-mail: e.cardona@cablelabs.com;mibs@cablelabs.com

             IETF IPCDN Working Group
             General Discussion: ipcdn@ietf.org
             Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
             Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
             Co-chairs: Richard Woundy, Richard_Woundy@cable.comcast.com
                        Jean-Francois Mule, jf.mule@cablelabs.com"
        DESCRIPTION
            "This is the MIB Module for DOCSIS 2.0-compliant Radio
             Frequency (RF) interfaces in Cable Modems and
             Cable Modem Termination Systems.

             Copyright (C) The Internet Society (2006).  This
             version of this MIB module is part of RFC 4546; see
             the RFC itself for full legal notices."

        REVISION        "200605240000Z"
        DESCRIPTION
            "Revision of the IETF RF MIB module for DOCSIS 2.0.
             This version published as RFC 4546.
             This MIB module revision includes the following
             among others:
             Usage of ifType (205) for upstream logical channels.
             Addition of downstream and upstream utilization
             counters.
             Additional statistics per upstream interface.
             Upstream channel offline configuration mechanism.
             Added MIB support for new DOCSIS 2.0 modulation
             attributes.
             Euro-DOCSIS downstream interleave values.
             Adjustments to RFC 2670 definitions based on
             the MIB review guidelines from the IETF



Raftus & Cardona            Standards Track                    [Page 25]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Operations and Management Area (OPS)."

        REVISION "199908190000Z"
        DESCRIPTION
            "Initial version, published as RFC 2670.
             Modified by Mike St. Johns to fix problems identified by
             the first pass of the MIB doctor.  Of special note,
             docsIfRangingResp and docsIfCmtsInsertionInterval were
             obsoleted and replaced by other objects with the same
             functionality, but with more appropriate syntax."
        ::= { transmission 127 }


   -- Textual Conventions

   TenthdBmV ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d-1"
        STATUS       current
        DESCRIPTION
            "This data type represents power levels that are normally
             expressed in dBmV.  Units are in tenths of a dBmV;
             for example, 5.1 dBmV will be represented as 51."
        SYNTAX       Integer32

   TenthdB ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d-1"
        STATUS       current
        DESCRIPTION
            "This data type represents power levels that are normally
             expressed in dB.  Units are in tenths of a dB;
             for example, 5.1 dB will be represented as 51."
        SYNTAX       Integer32

   DocsisVersion ::= TEXTUAL-CONVENTION
       STATUS          current
       DESCRIPTION
           "Indicates the DOCSIS Radio Frequency specification being
            referenced.
            'docsis10' indicates DOCSIS 1.0.
            'docsis11' indicates DOCSIS 1.1.
            'docsis20' indicates DOCSIS 2.0."
       SYNTAX        INTEGER {
            docsis10 (1),
            docsis11 (2),
            docsis20 (3)
       }

   DocsisQosVersion ::= TEXTUAL-CONVENTION



Raftus & Cardona            Standards Track                    [Page 26]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


       STATUS          current
       DESCRIPTION
           "Indicates the referenced quality-of-service
            level.
            'docsis10 refers to DOCSIS 1.0 Class of
            Service queuing services, and 'docsis11' refers
            to DOCSIS 1.1 Quality of Service."
       SYNTAX        INTEGER {
           docsis10 (1),
           docsis11 (2)
       }

   DocsisUpstreamType ::= TEXTUAL-CONVENTION
       STATUS          current
       DESCRIPTION
            "Indicates the DOCSIS Upstream Channel Type.
             'unknown' means information not available.
             'tdma' is related to TDMA, Time Division
             Multiple Access; 'atdma' is related to A-TDMA,
             Advanced Time Division Multiple Access,
             'scdma' is related to S-CDMA, Synchronous
             Code Division Multiple Access.
             'tdmaAndAtdma is related to simultaneous support of
             TDMA and A-TDMA modes."
       SYNTAX          INTEGER {
           unknown(0),
           tdma(1),
           atdma(2),
           scdma(3),
           tdmaAndAtdma(4)
       }

    DocsEqualizerData ::= TEXTUAL-CONVENTION
         STATUS       current
         DESCRIPTION
             "This data type represents the equalizer data
              as measured at the receiver interface.
              The format of the equalizer follows the structure of the
              Transmit Equalization Adjust RNG-RSP TLV of DOCSIS RFI
              v2.0 :
              1 byte Main tap location 1..(n + m)
              1 byte Number of forward taps per symbol
              1 byte Number of forward taps: n
              1 byte Number of reverse taps: m

              Following are the equalizer coefficients:
              First, forward taps coefficients:
              2 bytes F1 (real),  2 bytes  F1 (imag)



Raftus & Cardona            Standards Track                    [Page 27]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


              ...
              2 bytes Fn (real),  2 bytes  Fn (imag)

              Then, reverse taps coefficients:
              2 bytes D1 (real),  2 bytes  D1 (imag)
              ...

              2 bytes Dm (real),  2 bytes  Dm (imag)

              The equalizer coefficients are considered signed 16-bit
              integers in the range from -32768 (0x8000) to 32767
              (0x7FFF).

              DOCSIS specifications require up to a maximum of
              64 equalizer taps (n + m); therefore, this object size
               can get up 260 bytes (4 + 4x64).
              The minimum object size (other than zero) for a t-spaced
              tap with a minimum of 8 symbols will be 36 (4 + 4x8)."
         REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 8-23."
         SYNTAX       OCTET STRING(SIZE (0 | 36..260))


   docsIfMibObjects  OBJECT IDENTIFIER ::= { docsIfMib 1 }
   docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
   docsIfCmObjects   OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
   docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }

   --
   -- BASE GROUP
   --

   --
   -- The following table is implemented on both the Cable Modem
   -- and the Cable Modem Termination System.  This table is
   -- read only for the CM.
   --

   docsIfDownstreamChannelTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfDownstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table describes the attributes of downstream
             channels (frequency bands)."
        REFERENCE



Raftus & Cardona            Standards Track                    [Page 28]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-16, and 6-17."
        ::= { docsIfBaseObjects 1 }

   docsIfDownstreamChannelEntry OBJECT-TYPE
        SYNTAX      DocsIfDownstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry provides a list of attributes for a single
             downstream channel.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableDownstream(128)."
        INDEX { ifIndex }
        ::= { docsIfDownstreamChannelTable 1 }

   DocsIfDownstreamChannelEntry ::= SEQUENCE {
            docsIfDownChannelId               Integer32,
            docsIfDownChannelFrequency        Integer32,
            docsIfDownChannelWidth            Integer32,
            docsIfDownChannelModulation       INTEGER,
            docsIfDownChannelInterleave       INTEGER,
            docsIfDownChannelPower            TenthdBmV,
            docsIfDownChannelAnnex            INTEGER,
            docsIfDownChannelStorageType      StorageType
        }

   docsIfDownChannelId OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The Cable Modem Termination System identification of the
             downstream channel within this particular MAC interface.
             if the interface is down, the object returns the most
             current value.  If the downstream channel ID is unknown,
             this object returns a value of 0."
        ::= { docsIfDownstreamChannelEntry 1 }

   docsIfDownChannelFrequency OBJECT-TYPE
        SYNTAX      Integer32 (0..1000000000)
        UNITS       "hertz"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The center of the downstream frequency associated with
             this channel.  This object will return the current tuner



Raftus & Cardona            Standards Track                    [Page 29]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             frequency.  If a CMTS provides IF output, this object
             will return 0, unless this CMTS is in control of the
             final downstream frequency.  See the associated
             compliance object for a description of valid frequencies
             that may be written to this object."

        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.3.3."
        ::= { docsIfDownstreamChannelEntry 2 }

   docsIfDownChannelWidth OBJECT-TYPE
        SYNTAX      Integer32 (0..16000000)
        UNITS       "hertz"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The bandwidth of this downstream channel.  Most
             implementations are expected to support a channel width
             of 6 MHz (North America) and/or 8 MHz (Europe).  See the
             associated compliance object for a description of the
             valid channel widths for this object."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 6-17."
        ::= { docsIfDownstreamChannelEntry 3 }

   docsIfDownChannelModulation OBJECT-TYPE
        SYNTAX      INTEGER {
            unknown(1),
            other(2),
            qam64(3),
            qam256(4)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The modulation type associated with this downstream
             channel.  If the interface is down, this object either
             returns the configured value (CMTS), the most current
             value (CM), or the value of unknown(1).  See the
             associated conformance object for write conditions and
             limitations.  See the reference for specifics on the
             modulation profiles implied by qam64 and qam256."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio



Raftus & Cardona            Standards Track                    [Page 30]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 6-17."
        ::= { docsIfDownstreamChannelEntry 4 }

   docsIfDownChannelInterleave OBJECT-TYPE
        SYNTAX      INTEGER {
            unknown(1),
            other(2),
            taps8Increment16(3),
            taps16Increment8(4),
            taps32Increment4(5),
            taps64Increment2(6),
            taps128Increment1(7),
            taps12increment17(8)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The Forward Error Correction (FEC) interleaving used
             for this downstream channel.
             Values are defined as follows:
             taps8Increment16(3):   protection 5.9/4.1 usec,
                                    latency .22/.15 msec
             taps16Increment8(4):   protection 12/8.2 usec,
                                    latency .48/.33 msec
             taps32Increment4(5):   protection 24/16 usec,
                                    latency .98/.68 msec
             taps64Increment2(6):   protection 47/33 usec,
                                    latency 2/1.4 msec
             taps128Increment1(7):  protection 95/66 usec,
                                    latency 4/2.8 msec
             taps12increment17(8):  protection 18/14 usec,
                                    latency 0.43/0.32 msec

            The value 'taps12increment17' is supported by EuroDOCSIS
            cable systems only, and the others by DOCSIS cable systems.

             If the interface is down, this object either returns
             the configured value (CMTS), the most current value (CM),
             or the value of unknown(1).
             The value of other(2) is returned if the interleave
             is known but not defined in the above list.
             See the associated conformance object for write
             conditions and limitations.  See the reference for the FEC
             configuration described by the setting of this object."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,



Raftus & Cardona            Standards Track                    [Page 31]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Table 6-15."
        ::= { docsIfDownstreamChannelEntry 5 }

   docsIfDownChannelPower OBJECT-TYPE
        SYNTAX      TenthdBmV
        UNITS       "dBmV"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "At the CMTS, the operational transmit power.  At the CM,
             the received power level.
             If the interface is down, this object either returns
             the configured value (CMTS), the most current value (CM)
             or the value of 0.  See the associated conformance object
             for write conditions and limitations.  See the reference
             for recommended and required power levels."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-16, 6-17."
        ::= { docsIfDownstreamChannelEntry 6 }

   docsIfDownChannelAnnex OBJECT-TYPE
        SYNTAX      INTEGER {
            unknown(1),
            other(2),
            annexA(3),
            annexB(4),
            annexC(5)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value of this object indicates the conformance of
             the implementation to important regional cable standards.
             annexA : Annex A from ITU-T J.83 is used.
                      (equivalent to EN 300 429)
             annexB : Annex B from ITU-T J.83 is used.
             annexC : Annex C from ITU-T J.83 is used."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.3.1, and H.3.1."
        ::= { docsIfDownstreamChannelEntry 7 }

   docsIfDownChannelStorageType OBJECT-TYPE
        SYNTAX       StorageType
        MAX-ACCESS   read-only



Raftus & Cardona            Standards Track                    [Page 32]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        STATUS       current
        DESCRIPTION
            "The storage type for this conceptual row.
             Entries with this object set to permanent(4)
             do not require write operations for read-write
             objects."
        ::= { docsIfDownstreamChannelEntry 8 }

   --
   -- The following table is implemented on both the CM and the CMTS.
   -- For the CM, only attached channels appear in the table.  For the
   -- CM, this table is read-only as well.
   --

   docsIfUpstreamChannelTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfUpstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table describes the attributes of attached upstream
             channels."
        ::= { docsIfBaseObjects 2 }

   docsIfUpstreamChannelEntry OBJECT-TYPE
        SYNTAX      DocsIfUpstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "List of attributes for a single upstream channel.  For
             DOCSIS 2.0 CMTSs, an entry in this table exists for
             each ifEntry with an ifType of docsCableUpstreamChannel
             (205).
             For DOCSIS 1.x CM/CMTSs and DOCSIS 2.0 CMs, an entry in
             this table exists for each ifEntry with an ifType of
             docsCableUpstream (129).

             For DOCSIS 2.0 CMTSs, two classes of interfaces can be
             defined for this table:
              o Upstream Physical Interfaces: The traditional DOCSIS
                1.x CMTS upstream interface ifType 129 and the DOCSIS
                2.0 ifType 205 that are functional.  In other words,
                interfaces that represent upstream receivers within
                an RF MAC interface.
                Entries of physical interfaces are exposed to the
                management interface with their corresponding
                ifStack hierarchy and are not administratively
                created by this table.




Raftus & Cardona            Standards Track                    [Page 33]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


              o Upstream Temporary Interfaces: A fictitious
                interface created for the purpose of manipulating
                physical interface parameters offline, then
                validating prior to updating the target physical
                interface.

             In case of a reinitialization of the managed system,
             physical interfaces values persist while the temporary
             interfaces are not recreated.

             This mechanism helps to minimize service disruptions
             originating in situations where a group of interface
             parameter values need to be consistent with each other
             in SET operations.  A temporary buffer
             (temporary interface) is provided to allow the CMTS
             to validate the parameters offline."
        INDEX { ifIndex }
        ::= { docsIfUpstreamChannelTable 1 }

   DocsIfUpstreamChannelEntry ::= SEQUENCE {
            docsIfUpChannelId                     Integer32,
            docsIfUpChannelFrequency              Integer32,
            docsIfUpChannelWidth                  Integer32,
            docsIfUpChannelModulationProfile      Unsigned32,
            docsIfUpChannelSlotSize               Unsigned32,
            docsIfUpChannelTxTimingOffset         Unsigned32,
            docsIfUpChannelRangingBackoffStart    Integer32,
            docsIfUpChannelRangingBackoffEnd      Integer32,
            docsIfUpChannelTxBackoffStart         Integer32,
            docsIfUpChannelTxBackoffEnd           Integer32,
            docsIfUpChannelScdmaActiveCodes       Unsigned32,
            docsIfUpChannelScdmaCodesPerSlot      Integer32,
            docsIfUpChannelScdmaFrameSize         Unsigned32,
            docsIfUpChannelScdmaHoppingSeed       Unsigned32,
            docsIfUpChannelType                   DocsisUpstreamType,
            docsIfUpChannelCloneFrom              InterfaceIndexOrZero,
            docsIfUpChannelUpdate                 TruthValue,
            docsIfUpChannelStatus                 RowStatus,
            docsIfUpChannelPreEqEnable            TruthValue
        }

   docsIfUpChannelId OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The CMTS identification of the upstream channel."
        ::= { docsIfUpstreamChannelEntry 1 }



Raftus & Cardona            Standards Track                    [Page 34]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfUpChannelFrequency OBJECT-TYPE
        SYNTAX      Integer32 (0..1000000000)
        UNITS       "hertz"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The center of the frequency band associated with this
             upstream interface.  This object returns 0 if the frequency
             is undefined or unknown.  Minimum permitted upstream
             frequency is 5,000,000 Hz for current technology.  See
             the associated conformance object for write conditions
             and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 4-2."
        ::= { docsIfUpstreamChannelEntry 2 }

   docsIfUpChannelWidth OBJECT-TYPE
        SYNTAX      Integer32 (0..64000000)
        UNITS       "hertz"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The bandwidth of this upstream interface.  This object
             returns 0 if the interface width is undefined or unknown.
             Minimum permitted interface width is currently 200,000 Hz.
             See the associated conformance object for write conditions
             and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 6-5."
        ::= { docsIfUpstreamChannelEntry 3 }

   docsIfUpChannelModulationProfile OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "An entry identical to the docsIfModIndex in the
             docsIfCmtsModulationTable that describes this channel.
             This channel is further instantiated there by a grouping
             of interval usage codes (IUCs) that, together, fully
             describe the channel modulation.  This object returns 0 if
             the docsIfCmtsModulationTable entry does not exist or is
             empty.  See the associated conformance object for write
             conditions and limitations.



Raftus & Cardona            Standards Track                    [Page 35]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Setting this object returns an 'inconsistentValue'
             error if the following conditions are not satisfied:
             1. All the IUC entries in the selected modulation profile
             MUST have the same value of docsIfCmtsModChannelType.
             2. All of the Modulation parameters in the selected
             modulation profile MUST be consistent with the other
             parameters in this docsIfUpstreamChannelEntry."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-19."
        ::= { docsIfUpstreamChannelEntry 4 }

   docsIfUpChannelSlotSize OBJECT-TYPE
        SYNTAX      Unsigned32
        UNITS       "ticks"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Applicable to TDMA and ATDMA channel types only.
             The number of 6.25 microsecond ticks in each upstream
             mini-slot.  Returns zero if the value is undefined or
             unknown or in case of an SCDMA channel.
             See the associated conformance object for write
             conditions and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.1.2.4."
        ::= { docsIfUpstreamChannelEntry 5 }

   docsIfUpChannelTxTimingOffset OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "At the CM, a measure of the current round trip time
             obtained from the ranging offset (initial ranging offset +
             ranging offset adjustments).
             At the CMTS, the maximum of timing offset, among all the
             CMs that are/were present on the channel, taking into
             account all ( initial + periodic ) timing offset
             corrections that were sent for each of the CMs.  Generally,
             these measurements are positive, but if the measurements
             are negative, the value of this object is zero.  Used for
             timing of CM upstream transmissions to ensure synchronized
             arrivals at the CMTS.
             Units are one 64th fraction of 6.25 microseconds."



Raftus & Cardona            Standards Track                    [Page 36]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.19."
        ::= { docsIfUpstreamChannelEntry 6 }

   docsIfUpChannelRangingBackoffStart OBJECT-TYPE
        SYNTAX      Integer32 (0..16)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The initial random backoff window to use when retrying
             Ranging Requests.  Expressed as a power of 2.  A value of
             16 at the CMTS indicates that a proprietary adaptive retry
             mechanism is to be used.  See the associated conformance
             object for write conditions and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 8.3.4, and 9.4."
        ::= { docsIfUpstreamChannelEntry 7 }

   docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
        SYNTAX      Integer32 (0..16)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The final random backoff window to use when retrying
             Ranging Requests.  Expressed as a power of 2.  A value of
             16 at the CMTS indicates that a proprietary adaptive retry
             mechanism is to be used.  See the associated conformance
             object for write conditions and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.4, and 9.4."
        ::= { docsIfUpstreamChannelEntry 8 }

   docsIfUpChannelTxBackoffStart OBJECT-TYPE
        SYNTAX      Integer32 (0..16)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The initial random backoff window to use when retrying
             transmissions.  Expressed as a power of 2.  A value of 16
             at the CMTS indicates that a proprietary adaptive retry
             mechanism is to be used.  See the associated conformance
             object for write conditions and limitations."



Raftus & Cardona            Standards Track                    [Page 37]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.4, and 9.4."
        ::= { docsIfUpstreamChannelEntry 9 }

   docsIfUpChannelTxBackoffEnd OBJECT-TYPE
        SYNTAX      Integer32 (0..16)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The final random backoff window to use when retrying
             transmissions.  Expressed as a power of 2.  A value of 16
             at the CMTS indicates that a proprietary adaptive retry
             mechanism is to be used.  See the associated conformance
             object for write conditions and limitations."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.4, and 9.4."
        ::= { docsIfUpstreamChannelEntry 10 }

   docsIfUpChannelScdmaActiveCodes OBJECT-TYPE
        SYNTAX     Unsigned32 (0|64..66|68..70|72|74..78|80..82|84..88
                                |90..96|98..100|102|104..106|108
                                |110..112|114..126|128)
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "Applicable for SCDMA channel types only.
             Number of active codes.  Returns zero for
             Non-SCDMA channel types.  Note that legal
             values from 64..128 MUST be non-prime."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.11.2.1."
        ::= { docsIfUpstreamChannelEntry 11 }

   docsIfUpChannelScdmaCodesPerSlot OBJECT-TYPE
        SYNTAX      Integer32(0 | 2..32)
        UNITS       "codesperMinislots"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Applicable for SCDMA channel types only.
             The number of SCDMA codes per mini-slot.
             Returns zero if the value is undefined or unknown or in



Raftus & Cardona            Standards Track                    [Page 38]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             case of a TDMA or ATDMA channel."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.11.2.1."
        ::= { docsIfUpstreamChannelEntry 12 }

   docsIfUpChannelScdmaFrameSize OBJECT-TYPE
        SYNTAX      Unsigned32 (0..32)
        UNITS       "spreadIntervals"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Applicable for SCDMA channel types only.
             SCDMA Frame size in units of spreading intervals.
             This value returns zero for non-SCDMA Profiles."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.12."
        ::= { docsIfUpstreamChannelEntry 13 }

   docsIfUpChannelScdmaHoppingSeed OBJECT-TYPE
        SYNTAX     Unsigned32 (0..32767)
        MAX-ACCESS read-create
        STATUS     current
        DESCRIPTION
            "Applicable for SCDMA channel types only.
             15-bit seed used for code hopping sequence initialization.
             Returns zero for non-SCDMA channel types.
             Setting this value to a value different than zero for
             non-SCDMA channel types returns the error 'wrongValue'."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.14.1."
        ::= { docsIfUpstreamChannelEntry 14 }

   docsIfUpChannelType OBJECT-TYPE
        SYNTAX      DocsisUpstreamType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Reflects the Upstream channel type.
             This object returns the value of docsIfCmtsModChannelType
             for the modulation profile selected in
             docsIfUpChannelModulationProfile for this row."
        REFERENCE



Raftus & Cardona            Standards Track                    [Page 39]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.1."
        ::= { docsIfUpstreamChannelEntry 15 }

   docsIfUpChannelCloneFrom OBJECT-TYPE
        SYNTAX      InterfaceIndexOrZero
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object contains the ifIndex value of the physical
             interface row entry whose parameters are to be adjusted.

             Upon setting this object to the ifIndex value of a
             physical interface, the following interface objects values
             are copied to this entry:
             docsIfUpChannelFrequency,
             docsIfUpChannelWidth,
             docsIfUpChannelModulationProfile,
             docsIfUpChannelSlotSize,
             docsIfUpChannelRangingBackoffStart,
             docsIfUpChannelRangingBackoffEnd,
             docsIfUpChannelTxBackoffStart,
             docsIfUpChannelTxBackoffEnd,
             docsIfUpChannelScdmaActiveCodes,
             docsIfUpChannelScdmaCodesPerSlot,
             docsIfUpChannelScdmaFrameSize,
             docsIfUpChannelScdmaHoppingSeed,
             docsIfUpChannelType, and
             docsIfUpChannelPreEqEnable
             Setting this object to the value of a non-existent or
             a temporary upstream interface returns the error
             'wrongValue'.
             This object MUST contain a value of zero for physical
             interfaces entries.
             Setting this object in row entries that correspond to
             physical interfaces returns the error 'wrongValue'."
        ::= { docsIfUpstreamChannelEntry 16 }

   docsIfUpChannelUpdate OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Used to perform the copy of adjusted parameters from the
             temporary interface entry to the physical interface
             indicated by the docsIfUpChannelCloneFrom object.  The
             transfer is initiated through an SNMP SET to 'true' of



Raftus & Cardona            Standards Track                    [Page 40]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             this object.
             A SET to 'true' fails and returns error 'commitFailed'
             if docsIfUpChannelStatus value is 'notInService', which
             means that the interface parameters values are not
             compatible with each other or have not been validated yet.
             Reading this object always returns 'false'."
        ::= { docsIfUpstreamChannelEntry 17 }

   docsIfUpChannelStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object is only used for the creation of a temporary
             upstream row with the purpose of updating the parameters
             of a physical upstream channel entry.

             The following restrictions apply to this object:
             1. This object is not writable for physical interfaces.
             2. Temporary interface entries are only created by a SET
                of this object to createandWait(5).
             3. ifAdminStatus from the Interface MIB RFC 2863 is used
                to take a physical upstream channel offline, to be
                consistent with DOCSIS 1.x operation, as indicated in
                RFC 2670.
                In addition,
                 o ifAdminStatus 'down' is reflected in this object
                   as 'notInService'.
                 o ifOperStatus 'down' while ifAdminStatus 'up' is
                   reflected in this object as 'notInservice'.
             4. Temporary created rows MUST be set to 'active' with
                the purpose of validating upstream parameter
                consistency prior to transferring the parameters to the
                physical interface.

             Below is a mandatory procedure for adjusting the values
             of a physical interface:
             1. Create a temporary interface entry through an SNMP SET
                using 'createAndWait'.  At this point, the RowStatus
                reports 'notReady'.
                The Manager entity uses an ifIndex value outside the
                operational range of the physical interfaces for the
                creation of a temporary interface.
             2. Set the docsIfUpChannelCloneFrom object to the ifIndex
                value of the physical row to update.  Now
                docsIfUpChannelStatus reports 'notInService'.
             3. Change the upstream parameters to the desired values
                in the temporary row.



Raftus & Cardona            Standards Track                    [Page 41]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             4. Validate that all parameters are consistent by setting
                docsIfUpChannelStatus to 'active'.  A failure to set the
                RowStatus to 'active' returns the error 'commitFailed',
                which means the parameters are not compatible with the
                target physical interface.
             5. With docsIfUpChannelStatus 'active', transfer the
                parameters to the target physical interface by setting
                the object docsIfUpChannelUpdate to 'true'.
             6. Delete the temporary row by setting
                docsIfUpChannelStatus to 'destroy'."
        ::= { docsIfUpstreamChannelEntry 18 }

   docsIfUpChannelPreEqEnable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "At the CMTS, this object is used to enable or disable
             pre-equalization on the upstream channel represented by
             this table instance.  At the CM, this object is read-only
             and reflects the status of pre-equalization as represented
             in the RNG-RSP.  Pre-equalization is considered enabled at
             the CM if a RNG-RSP with pre-equalization data has been
             received at least once since the last mac
             reinitialization."
        DEFVAL {false}
        ::= { docsIfUpstreamChannelEntry 19 }

   -- The following table describes the attributes of each class of
   -- service.  The entries in this table are referenced from the
   -- docsIfServiceEntries.  They exist as a separate table in order to
   -- reduce redundant information in docsIfServiceTable.
   --
   -- This table is implemented at both the CM and the CMTS.
   -- The CM need only maintain entries for the classes of service
   -- referenced by its docsIfCmServiceTable.
   --

   docsIfQosProfileTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfQosProfileEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes for each class of service."
        ::= { docsIfBaseObjects 3 }

   docsIfQosProfileEntry OBJECT-TYPE
        SYNTAX      DocsIfQosProfileEntry



Raftus & Cardona            Standards Track                    [Page 42]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes for a single class of service.
             If implemented as read-create in the Cable Modem
             Termination System, creation of entries in this table is
             controlled by the value of
             docsIfCmtsQosProfilePermissions.

             If implemented as read-only, entries are created based
             on information in REG-REQ MAC messages received from
             cable modems (for Cable Modem Termination System), or
             based on information extracted from the TFTP option file
             (for Cable Modem).
             In the Cable Modem Termination System, read-only entries
             are removed if no longer referenced by
             docsIfCmtsServiceTable.

             An entry in this table MUST not be removed while it is
             referenced by an entry in docsIfCmServiceTable (Cable
             Modem) or docsIfCmtsServiceTable (Cable Modem Termination
             System).

             An entry in this table SHOULD NOT be changeable while
             it is referenced by an entry in docsIfCmtsServiceTable.

             If this table is created automatically, there SHOULD only
             be a single entry for each Class of Service.  Multiple
             entries with the same Class of Service parameters are NOT
             RECOMMENDED."
        INDEX { docsIfQosProfIndex }
        ::= { docsIfQosProfileTable 1 }

   DocsIfQosProfileEntry ::= SEQUENCE {
            docsIfQosProfIndex                Integer32,
            docsIfQosProfPriority             Integer32,
            docsIfQosProfMaxUpBandwidth       Integer32,
            docsIfQosProfGuarUpBandwidth      Integer32,
            docsIfQosProfMaxDownBandwidth     Integer32,
            docsIfQosProfMaxTxBurst           Integer32,  -- deprecated
            docsIfQosProfBaselinePrivacy      TruthValue,
            docsIfQosProfStatus               RowStatus,
            docsIfQosProfMaxTransmitBurst     Integer32,
            docsIfQosProfStorageType          StorageType
        }

   docsIfQosProfIndex OBJECT-TYPE
        SYNTAX      Integer32 (1..16383)



Raftus & Cardona            Standards Track                    [Page 43]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The index value that uniquely identifies an entry
             in the docsIfQosProfileTable."
        ::= { docsIfQosProfileEntry 1 }

   docsIfQosProfPriority OBJECT-TYPE
        SYNTAX      Integer32 (0..7)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "A relative priority assigned to this service when
             allocating bandwidth.  Zero indicates lowest priority
             and seven indicates highest priority.
             Interpretation of priority is device-specific.
             MUST NOT be changed while this row is active."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex C.1.1.4."
        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 2 }

   docsIfQosProfMaxUpBandwidth OBJECT-TYPE
        SYNTAX      Integer32 (0..100000000)
        UNITS "bits per second"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The maximum upstream bandwidth, in bits per second,
             allowed for a service with this service class.
             Zero if there is no restriction of upstream bandwidth.
             MUST NOT be changed while this row is active."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex C.1.1.4."
        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 3 }

   docsIfQosProfGuarUpBandwidth OBJECT-TYPE
        SYNTAX      Integer32 (0..100000000)
        UNITS "bits per second"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Minimum guaranteed upstream bandwidth, in bits per second,



Raftus & Cardona            Standards Track                    [Page 44]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             allowed for a service with this service class.
             MUST NOT be changed while this row is active."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex C.1.1.4."
        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 4 }

   docsIfQosProfMaxDownBandwidth OBJECT-TYPE
        SYNTAX      Integer32 (0..100000000)
        UNITS "bits per second"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The maximum downstream bandwidth, in bits per second,
             allowed for a service with this service class.
             Zero if there is no restriction of downstream bandwidth.
             MUST NOT be changed while this row is active."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex C.1.1.4."

        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 5 }

   docsIfQosProfMaxTxBurst OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        UNITS "mini-slots"
        MAX-ACCESS  read-create
        STATUS      deprecated
        DESCRIPTION
            "The maximum number of mini-slots that may be requested
             for a single upstream transmission.
             A value of zero means there is no limit.
             MUST NOT be changed while this row is active.
             This object has been deprecated and replaced by
             docsIfQosProfMaxTransmitBurst, to fix a mismatch
             of the units and value range with respect to the DOCSIS
             Maximum Upstream Channel Transmit Burst Configuration
             Setting."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             C.1.1.4."
        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 6 }



Raftus & Cardona            Standards Track                    [Page 45]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfQosProfBaselinePrivacy OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Indicates whether Baseline Privacy is enabled for this
             service class.
             MUST NOT be changed while this row is active."
        DEFVAL { false }
        ::= { docsIfQosProfileEntry 7 }

   docsIfQosProfStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This is object is used to create or delete rows in
             this table.  This object MUST NOT be changed from active
             while the row is referenced by any entry in either
             docsIfCmServiceTable (on the CM) or
             docsIfCmtsServiceTable (on the CMTS)."
        ::= { docsIfQosProfileEntry 8 }

   docsIfQosProfMaxTransmitBurst OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        UNITS       "bytes"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The maximum number of bytes that may be requested for a
             single upstream transmission.  A value of zero means there
             is no limit.  Note: This value does not include any
             physical layer overhead.
             MUST NOT be changed while this row is active."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex C.1.1.4."
        DEFVAL { 0 }
        ::= { docsIfQosProfileEntry 9 }

   docsIfQosProfStorageType OBJECT-TYPE
        SYNTAX       StorageType
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
            "The storage type for this conceptual row.
             Entries with this object set to permanent(4)



Raftus & Cardona            Standards Track                    [Page 46]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             do not require write operations for writable
             objects."
        ::= { docsIfQosProfileEntry 10 }

   docsIfSignalQualityTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfSignalQualityEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "At the CM, describes the PHY signal quality of downstream
             channels.  At the CMTS, this object describes the PHY
             signal quality of upstream channels.  At the CMTS, this
             table MAY exclude contention intervals."
        ::= { docsIfBaseObjects 4 }

   docsIfSignalQualityEntry OBJECT-TYPE
        SYNTAX      DocsIfSignalQualityEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "At the CM, this object describes the PHY characteristics of
             a downstream channel.  At the CMTS, it describes the PHY
             signal quality of an upstream channel.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableDownstream(128) for Cable Modems.
             For DOCSIS 1.1 Cable Modem Termination Systems, an entry
             exists for each ifEntry with an ifType of
             docsCableUpstream (129).
             For DOCSIS 2.0 Cable Modem Termination Systems, an entry
             exists for each ifEntry with an ifType of
             docsCableUpstreamChannel (205)."
        INDEX { ifIndex }
        ::= { docsIfSignalQualityTable 1 }

   DocsIfSignalQualityEntry ::= SEQUENCE {
            docsIfSigQIncludesContention  TruthValue,
            docsIfSigQUnerroreds          Counter32,
            docsIfSigQCorrecteds          Counter32,
            docsIfSigQUncorrectables      Counter32,
            docsIfSigQSignalNoise         TenthdB,
            docsIfSigQMicroreflections    Integer32,
            docsIfSigQEqualizationData    DocsEqualizerData,
            docsIfSigQExtUnerroreds       Counter64,
            docsIfSigQExtCorrecteds       Counter64,
            docsIfSigQExtUncorrectables   Counter64
        }

   docsIfSigQIncludesContention OBJECT-TYPE



Raftus & Cardona            Standards Track                    [Page 47]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "true(1) if this CMTS includes contention intervals in
             the counters in this table.  Always false(2) for CMs."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4.1"
        ::= { docsIfSignalQualityEntry 1 }

   docsIfSigQUnerroreds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel without error.
             This includes all codewords, whether or not they
             were part of frames destined for this device.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, and 6.3.6."
        ::= { docsIfSignalQualityEntry 2 }

   docsIfSigQCorrecteds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel with correctable
             errors.  This includes all codewords, whether or not
             they were part of frames destined for this device.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, and 6.3.6."



Raftus & Cardona            Standards Track                    [Page 48]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        ::= { docsIfSignalQualityEntry 3 }

   docsIfSigQUncorrectables OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel with uncorrectable
             errors.  This includes all codewords, whether or not
             they were part of frames destined for this device.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, and 6.3.6."
        ::= { docsIfSignalQualityEntry 4 }

   docsIfSigQSignalNoise OBJECT-TYPE
        SYNTAX      TenthdB
        UNITS       "TenthdB"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Signal/Noise ratio as perceived for this channel.
             At the CM, this object  describes the Signal/Noise of the
             downstream channel.  At the CMTS, it describes the
             average Signal/Noise of the upstream channel."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 4-1 and 4-2"
        ::= { docsIfSignalQualityEntry 5 }

   docsIfSigQMicroreflections OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        UNITS       "-dBc"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Microreflections, including in-channel response
             as perceived on this interface, measured in dBc below
             the signal level.
             This object is not assumed to return an absolutely
             accurate value, but it gives a rough indication



Raftus & Cardona            Standards Track                    [Page 49]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             of microreflections received on this interface.
             It is up to the implementer to provide information
             as accurately as possible."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 4-1 and 4-2"
        ::= { docsIfSignalQualityEntry 6 }

   docsIfSigQEqualizationData OBJECT-TYPE
           SYNTAX      DocsEqualizerData
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "At the CM, this object returns the equalization data for
                the downstream channel.

                At the CMTS, this object is not applicable and is not
                instantiated.  Note that previous CMTS implementations
                may instantiate this object in two ways:
                - An equalization value indicating an equalization
                  average for the upstream channel.  Those values have
                  vendor-dependent interpretations.
                - Return a zero-length OCTET STRING to indicate that
                  the value is unknown or if there is no equalization
                  data available or defined."
           REFERENCE
               "DOCSIS Radio Frequency Interface Specification,
                Figure 6-23."
           ::= { docsIfSignalQualityEntry 7 }


   docsIfSigQExtUnerroreds OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel without error.
             This includes all codewords, whether or not they
             were part of frames destined for this device.
             This is the 64-bit version of docsIfSigQUnerroreds.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio



Raftus & Cardona            Standards Track                    [Page 50]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, and 6.3.6."
        ::= { docsIfSignalQualityEntry 8 }

   docsIfSigQExtCorrecteds OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel with correctable
             errors.  This includes all codewords, whether or not
             they were part of frames destined for this device.
             This is the 64-bit version of docsIfSigQCorrecteds.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, and 6.3.6."
        ::= { docsIfSignalQualityEntry 9 }

   docsIfSigQExtUncorrectables OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received on this channel with uncorrectable
             errors.  This includes all codewords, whether or not
             they were part of frames destined for this device.
             This is the 64-bit version of docsIfSigQUncorrectables.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Sections 6.2.4, 6.3.6."
        ::= { docsIfSignalQualityEntry 10 }

   --
   -- DOCSIS Version of the device
   --




Raftus & Cardona            Standards Track                    [Page 51]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfDocsisBaseCapability OBJECT-TYPE
           SYNTAX      DocsisVersion
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "Indication of the DOCSIS capability of the device."
           REFERENCE
               "Data-Over-Cable Service Interface Specifications: Radio
                Frequency Interface Specification SP-RFIv2.0-I10-051209,
                Annex G."
           ::= { docsIfBaseObjects 5 }

   --
   -- CABLE MODEM GROUP
   --

   --
   -- The CM MAC Table
   --

   docsIfCmMacTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmMacEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes of each CM MAC interface,
             extending the information available from ifEntry."
        ::= { docsIfCmObjects 1 }

   docsIfCmMacEntry OBJECT-TYPE
        SYNTAX      DocsIfCmMacEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry containing objects describing attributes of
             each MAC entry, extending the information in ifEntry.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableMaclayer(127)."
        INDEX { ifIndex }
        ::= { docsIfCmMacTable 1 }

   DocsIfCmMacEntry ::= SEQUENCE {
            docsIfCmCmtsAddress           MacAddress,
            docsIfCmCapabilities          BITS,
            docsIfCmRangingRespTimeout    TimeTicks,
            docsIfCmRangingTimeout        TimeInterval
         }




Raftus & Cardona            Standards Track                    [Page 52]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfCmCmtsAddress OBJECT-TYPE
        SYNTAX      MacAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Identifies the CMTS that is believed to control this MAC
             domain.  At the CM, this will be the source address from
             SYNC, MAP, and other MAC-layer messages.  If the CMTS is
             unknown, returns 00-00-00-00-00-00."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.2.2."
        ::= { docsIfCmMacEntry 1 }

   docsIfCmCapabilities OBJECT-TYPE
        SYNTAX      BITS {
            atmCells(0),
            concatenation(1)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Identifies the capabilities of the MAC implementation
             at this interface.  Note that packet transmission is
             always supported.  Therefore, there is no specific bit
             required to explicitly indicate this capability.
             Note that BITS objects are encoded most significant bit
             first.  For example, if bit 1 is set, the value of this
             object is the octet string '40'H."
        ::= { docsIfCmMacEntry 2 }

   docsIfCmRangingRespTimeout OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  read-write
        STATUS      obsolete
        DESCRIPTION
            "Waiting time for a Ranging Response packet.
             This object has been obsoleted and replaced by
             docsIfCmRangingTimeout to correct the typing to
             TimeInterval."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.1.6."
        DEFVAL { 20 }
        ::= { docsIfCmMacEntry 3 }




Raftus & Cardona            Standards Track                    [Page 53]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfCmRangingTimeout OBJECT-TYPE
        SYNTAX      TimeInterval
        UNITS       "HundredOfSeconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Waiting time for a Ranging Response packet.
             This object MUST NOT persist at reinitialization
             of the managed system."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.1.6, timer T3."
        DEFVAL { 20 }
        ::= { docsIfCmMacEntry 4 }

   --
   -- CM status table.
   -- This table is implemented only at the CM.
   --

   docsIfCmStatusTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table maintains a number of status objects
             and counters for Cable Modems."
        ::= { docsIfCmObjects 2 }

   docsIfCmStatusEntry OBJECT-TYPE
        SYNTAX      DocsIfCmStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A set of status objects and counters for a single MAC
             layer instance in Cable Modem.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableMaclayer(127)."
        INDEX { ifIndex }
        ::= { docsIfCmStatusTable 1 }

   DocsIfCmStatusEntry ::= SEQUENCE {
            docsIfCmStatusValue               INTEGER,
            docsIfCmStatusCode                OCTET STRING,
            docsIfCmStatusTxPower             TenthdBmV,
            docsIfCmStatusResets              Counter32,
            docsIfCmStatusLostSyncs           Counter32,



Raftus & Cardona            Standards Track                    [Page 54]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmStatusInvalidMaps         Counter32,
            docsIfCmStatusInvalidUcds         Counter32,
            docsIfCmStatusInvalidRangingResponses   Counter32,
            docsIfCmStatusInvalidRegistrationResponses Counter32,
            docsIfCmStatusT1Timeouts          Counter32,
            docsIfCmStatusT2Timeouts          Counter32,
            docsIfCmStatusT3Timeouts          Counter32,
            docsIfCmStatusT4Timeouts          Counter32,
            docsIfCmStatusRangingAborteds     Counter32,
            docsIfCmStatusDocsisOperMode      DocsisQosVersion,
            docsIfCmStatusModulationType      DocsisUpstreamType,
            docsIfCmStatusEqualizationData    DocsEqualizerData,
            docsIfCmStatusUCCs                Counter32,
            docsIfCmStatusUCCFails            Counter32
        }

   docsIfCmStatusValue OBJECT-TYPE
        SYNTAX      INTEGER {
            other(1),
            notReady(2),
            notSynchronized(3),
            phySynchronized(4),
            usParametersAcquired(5),
            rangingComplete(6),
            ipComplete(7),
            todEstablished(8),
            securityEstablished(9),
            paramTransferComplete(10),
            registrationComplete(11),
            operational(12),
            accessDenied(13)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current Cable Modem connectivity state, as specified
             in the RF Interface Specification.  Interpretations for
             state values 1-12 are clearly outlined in the SP-RFI
             reference given below.
             The state value accessDenied(13) indicates the CMTS has
             sent a Registration Aborted message to the CM.  The same
             state is reported as accessDenied(7) by the CMTS object
             docsIfCmtsCmStatusValue."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 11.2.
             Data-Over-Cable Service Interface Specifications:



Raftus & Cardona            Standards Track                    [Page 55]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Operations Support System Interface Specification
             SP-OSSIv2.0-I09-050812, Section 6.3.4.2."
        ::= { docsIfCmStatusEntry 1 }

   docsIfCmStatusCode OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE( 0 | 5 | 6 ))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Status code for a Cable Modem as defined in the
             OSSI Specification.  The status code consists
             of a single character indicating error groups, followed
             by a two- or three-digit number indicating the status
             condition, followed by a decimal.
             An example of a returned value could be 'T101.0'.
             The zero-length OCTET STRING indicates no status code yet
             registered."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications:
             Operations Support System Interface Specification
             SP-OSSIv2.0-I09-050812, Annex D."
        ::= { docsIfCmStatusEntry 2 }


   docsIfCmStatusTxPower OBJECT-TYPE
        SYNTAX      TenthdBmV
        UNITS       "TenthdBmV"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The operational transmit power for the attached upstream
             channel."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.18."
        ::= { docsIfCmStatusEntry 3 }

   docsIfCmStatusResets OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "resets"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM reset or initialized this
             interface.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other



Raftus & Cardona            Standards Track                    [Page 56]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmStatusEntry 4 }

   docsIfCmStatusLostSyncs OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM lost synchronization with
             the downstream channel.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.2."
        ::= { docsIfCmStatusEntry 5 }

   docsIfCmStatusInvalidMaps OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "maps"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM received invalid MAP messages.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.4."
        ::= { docsIfCmStatusEntry 6 }

   docsIfCmStatusInvalidUcds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM received invalid UCD messages.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of



Raftus & Cardona            Standards Track                    [Page 57]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.3."
        ::= { docsIfCmStatusEntry 7 }

   docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM received invalid ranging response
             messages.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.6."
        ::= { docsIfCmStatusEntry 8 }

   docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the CM received invalid registration
             response messages.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.8."
        ::= { docsIfCmStatusEntry 9 }

   docsIfCmStatusT1Timeouts OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "timeouts"
        MAX-ACCESS  read-only
        STATUS      current



Raftus & Cardona            Standards Track                    [Page 58]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "Number of times counter T1 expired in the CM.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 9-2."
        ::= { docsIfCmStatusEntry 10 }

   docsIfCmStatusT2Timeouts OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "timeouts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times counter T2 expired in the CM.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 9-2."
        ::= { docsIfCmStatusEntry 11 }

   docsIfCmStatusT3Timeouts OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "timeouts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times counter T3 expired in the CM.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 9-2."
        ::= { docsIfCmStatusEntry 12 }

   docsIfCmStatusT4Timeouts OBJECT-TYPE
        SYNTAX      Counter32



Raftus & Cardona            Standards Track                    [Page 59]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        UNITS       "timeouts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times counter T4 expired in the CM.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 9-2."
        ::= { docsIfCmStatusEntry 13 }

   docsIfCmStatusRangingAborteds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Number of times the ranging process was aborted
             by the CMTS.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.3.3."
        ::= { docsIfCmStatusEntry 14 }

   docsIfCmStatusDocsisOperMode OBJECT-TYPE
        SYNTAX      DocsisQosVersion
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
             "Indication of whether the device has registered using 1.0
              Class of Service or 1.1 Quality of Service.
              An unregistered CM SHOULD indicate 'docsis11' for a
              docsIfDocsisBaseCapability value of DOCSIS 1.1/2.0.  An
              unregistered CM SHOULD indicate 'docsis10'  for a
              docsIfDocsisBaseCapability value of DOCSIS 1.0."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex G."



Raftus & Cardona            Standards Track                    [Page 60]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        ::= { docsIfCmStatusEntry 15 }

   docsIfCmStatusModulationType OBJECT-TYPE
         SYNTAX      DocsisUpstreamType
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Indicates modulation type status currently used by the
              CM.  Since this object specifically identifies PHY mode,
              the shared upstream channel type is not permitted."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.1."

         ::= { docsIfCmStatusEntry 16 }

   docsIfCmStatusEqualizationData OBJECT-TYPE
        SYNTAX      DocsEqualizerData
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Pre-equalization data for this CM after convolution with
             data indicated in the RNG-RSP.  This data is valid when
             docsIfUpChannelPreEqEnable is set to true."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 8-23."
        ::= { docsIfCmStatusEntry 17 }

   docsIfCmStatusUCCs OBJECT-TYPE
        SYNTAX          Counter32
        UNITS           "attempts"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The number of successful Upstream Channel Change
             transactions.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmStatusEntry 18 }

   docsIfCmStatusUCCFails OBJECT-TYPE
        SYNTAX          Counter32
        UNITS           "attempts"



Raftus & Cardona            Standards Track                    [Page 61]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The number of failed Upstream Channel Change
             transactions.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmStatusEntry 19 }

   --
   -- The Cable Modem Service Table
   --

   docsIfCmServiceTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmServiceEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes of each upstream service queue
             on a CM."
        ::= { docsIfCmObjects 3 }

   docsIfCmServiceEntry OBJECT-TYPE
        SYNTAX      DocsIfCmServiceEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes of an upstream bandwidth service
             queue.
             An entry in this table exists for each Service ID.
             The primary index is an ifIndex with an ifType of
             docsCableMaclayer(127)."
        INDEX { ifIndex, docsIfCmServiceId }
        ::= { docsIfCmServiceTable 1 }

   DocsIfCmServiceEntry ::= SEQUENCE {
            docsIfCmServiceId               Integer32,
            docsIfCmServiceQosProfile       Integer32,
            docsIfCmServiceTxSlotsImmed     Counter32,
            docsIfCmServiceTxSlotsDed       Counter32,
            docsIfCmServiceTxRetries        Counter32,
            docsIfCmServiceTxExceededs      Counter32,
            docsIfCmServiceRqRetries        Counter32,
            docsIfCmServiceRqExceededs      Counter32,
            docsIfCmServiceExtTxSlotsImmed  Counter64,
            docsIfCmServiceExtTxSlotsDed    Counter64



Raftus & Cardona            Standards Track                    [Page 62]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


         }

   docsIfCmServiceId OBJECT-TYPE
        SYNTAX      Integer32 (1..16383)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Identifies a service queue for upstream bandwidth.  The
             attributes of this service queue are shared between the
             CM and the CMTS.  The CMTS allocates upstream bandwidth
             to this service queue based on requests from the CM and
             on the class of service associated with this queue."
        ::= { docsIfCmServiceEntry 1 }

   docsIfCmServiceQosProfile OBJECT-TYPE
        SYNTAX      Integer32 (0..16383)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The index in docsIfQosProfileTable describing the quality
             of service attributes associated with this particular
             service.  If no associated entry in docsIfQosProfileTable
             exists, this object returns a value of zero."
        ::= { docsIfCmServiceEntry 2 }

   docsIfCmServiceTxSlotsImmed OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of upstream mini-slots that have been used to
             transmit data PDUs in immediate (contention) mode.  This
             includes only those PDUs that are presumed to have
             arrived at the head-end (i.e., those that were explicitly
             acknowledged).  It does not include retransmission attempts
             or mini-slots used by requests.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 3 }

   docsIfCmServiceTxSlotsDed OBJECT-TYPE



Raftus & Cardona            Standards Track                    [Page 63]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of upstream mini-slots that have been used to
             transmit data PDUs in dedicated mode (i.e., as a result
             of a unicast Data Grant).
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 4 }

   docsIfCmServiceTxRetries OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of attempts to transmit data PDUs containing
             requests for acknowledgment that did not result in
             acknowledgment.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 5 }

   docsIfCmServiceTxExceededs OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of data PDU transmission failures due to
             excessive retries without acknowledgment.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of



Raftus & Cardona            Standards Track                    [Page 64]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 6 }

   docsIfCmServiceRqRetries OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of attempts to transmit bandwidth requests
             that did not result in acknowledgment.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 7 }

   docsIfCmServiceRqExceededs OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of requests for bandwidth that failed due to
             excessive retries without acknowledgment.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 8 }

   docsIfCmServiceExtTxSlotsImmed OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current



Raftus & Cardona            Standards Track                    [Page 65]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "The number of upstream mini-slots that have been used to
             transmit data PDUs in immediate (contention) mode.  This
             includes only those PDUs that are presumed to have
             arrived at the head-end (i.e., those that were explicitly
             acknowledged).  It does not include retransmission attempts
             or mini-slots used by requests.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 9 }

   docsIfCmServiceExtTxSlotsDed OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of upstream mini-slots that have been used to
             transmit data PDUs in dedicated mode (i.e., as a result
             of a unicast Data Grant).
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.4."
        ::= { docsIfCmServiceEntry 10 }

   --
   -- CMTS GROUP
   --

   --
   -- The CMTS MAC Table
   --

   docsIfCmtsMacTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsMacEntry
        MAX-ACCESS  not-accessible
        STATUS      current



Raftus & Cardona            Standards Track                    [Page 66]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "Describes the attributes of each CMTS MAC interface,
             extending the information available from ifEntry.
             Mandatory for all CMTS devices."
        ::= { docsIfCmtsObjects 1 }

   docsIfCmtsMacEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsMacEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry containing objects describing attributes of each
             MAC entry, extending the information in ifEntry.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableMaclayer(127)."
        INDEX { ifIndex }
        ::= { docsIfCmtsMacTable 1 }

   DocsIfCmtsMacEntry ::= SEQUENCE {
            docsIfCmtsCapabilities            BITS,
            docsIfCmtsSyncInterval            Integer32,
            docsIfCmtsUcdInterval             Integer32,
            docsIfCmtsMaxServiceIds           Integer32,
            docsIfCmtsInsertionInterval       TimeTicks,   -- Obsolete
            docsIfCmtsInvitedRangingAttempts  Integer32,
            docsIfCmtsInsertInterval          TimeInterval,
            docsIfCmtsMacStorageType          StorageType
        }

   docsIfCmtsCapabilities OBJECT-TYPE
        SYNTAX      BITS {
            atmCells(0),
            concatenation(1)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Identifies the capabilities of the CMTS MAC
             implementation at this interface.  Note that packet
             transmission is always supported.  Therefore, there
             is no specific bit required to explicitly indicate
             this capability.
             Note that BITS objects are encoded most significant bit
             first.  For example, if bit 1 is set, the value of this
             object is the octet string '40'H."
        ::= { docsIfCmtsMacEntry 1 }

   docsIfCmtsSyncInterval OBJECT-TYPE



Raftus & Cardona            Standards Track                    [Page 67]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        SYNTAX      Integer32 (1..200)
        UNITS       "Milliseconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The interval between CMTS transmission of successive SYNC
             messages at this interface."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.3."
        ::= { docsIfCmtsMacEntry 2 }

   docsIfCmtsUcdInterval OBJECT-TYPE
        SYNTAX      Integer32 (1..2000)
        UNITS       "Milliseconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The interval between CMTS transmission of successive
             Upstream Channel Descriptor messages for each upstream
             channel at this interface."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.3"
        ::= { docsIfCmtsMacEntry 3 }

   docsIfCmtsMaxServiceIds OBJECT-TYPE
        SYNTAX     Integer32 (1..16383)
        UNITS      "SIDs"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
            "The maximum number of service IDs that may be
             simultaneously active."
        ::= { docsIfCmtsMacEntry 4 }

   docsIfCmtsInsertionInterval OBJECT-TYPE
        SYNTAX      TimeTicks
        MAX-ACCESS  read-write
        STATUS      obsolete
        DESCRIPTION
            "The amount of time to elapse between each broadcast
             initial maintenance grant.  Broadcast initial maintenance
             grants are used to allow new cable modems to join the
             network.  Zero indicates that a vendor-specific algorithm
             is used instead of a fixed time.  The maximum amount of



Raftus & Cardona            Standards Track                    [Page 68]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             time permitted by the specification is 2 seconds.
             This object has been obsoleted and replaced by
             docsIfCmtsInsertInterval to fix a SYNTAX typing problem."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex B."
        ::= { docsIfCmtsMacEntry 5 }

   docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
        SYNTAX      Integer32 (0..1024)
        UNITS      "attempts"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum number of attempts to make on invitations
             for ranging requests.  A value of zero means the system
             SHOULD attempt to range forever."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 9.3.3 and Annex B."
        ::= { docsIfCmtsMacEntry 6 }

   docsIfCmtsInsertInterval OBJECT-TYPE
        SYNTAX      TimeInterval
        UNITS       "HundredOfSeconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The amount of time to elapse between each broadcast
             initial maintenance grant.  Broadcast initial maintenance
             grants are used to allow new cable modems to join the
             network.  Zero indicates that a vendor-specific algorithm
             is used instead of a fixed time.  The maximum amount of
             time permitted by the specification is 2 seconds."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex B."
        ::= { docsIfCmtsMacEntry 7 }

   docsIfCmtsMacStorageType OBJECT-TYPE
        SYNTAX       StorageType
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
            "The storage type for this conceptual row.



Raftus & Cardona            Standards Track                    [Page 69]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Entries with this object set to permanent(4)
             do not require write operations for read-write
             objects."
        ::= { docsIfCmtsMacEntry 8 }

   --
   --
   -- CMTS status table.
   --

   docsIfCmtsStatusTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "For the MAC layer, this group maintains a number of
             status objects and counters."
        ::= { docsIfCmtsObjects 2 }

   docsIfCmtsStatusEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
           "Status entry for a single MAC layer.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableMaclayer(127)."
        INDEX { ifIndex }
        ::= { docsIfCmtsStatusTable 1 }

   DocsIfCmtsStatusEntry ::= SEQUENCE {
            docsIfCmtsStatusInvalidRangeReqs        Counter32,
            docsIfCmtsStatusRangingAborteds         Counter32,
            docsIfCmtsStatusInvalidRegReqs          Counter32,
            docsIfCmtsStatusFailedRegReqs           Counter32,
            docsIfCmtsStatusInvalidDataReqs         Counter32,
            docsIfCmtsStatusT5Timeouts              Counter32
        }

   docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts invalid RNG-REQ messages received on
             this interface.
             Discontinuities in the value of this counter can occur



Raftus & Cardona            Standards Track                    [Page 70]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.5."
        ::= { docsIfCmtsStatusEntry 1 }

   docsIfCmtsStatusRangingAborteds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts ranging attempts that were explicitly
             aborted by the CMTS.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.6."
        ::= { docsIfCmtsStatusEntry 2 }

   docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts invalid REG-REQ messages received on
             this interface; that is, syntax, out of range parameters,
             or erroneous requests.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.7."
        ::= { docsIfCmtsStatusEntry 3 }

   docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
        SYNTAX      Counter32



Raftus & Cardona            Standards Track                    [Page 71]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        UNITS       "attempts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts failed registration attempts.  Included
             are docsIfCmtsStatusInvalidRegReqs, authentication, and
             class of service failures.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.3.7."
        ::= { docsIfCmtsStatusEntry 4 }

   docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "messages"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts invalid data request messages
             received on this interface.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsStatusEntry 5 }

   docsIfCmtsStatusT5Timeouts OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "timeouts"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object counts the number of times counter T5
             expired on this interface.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 9-2."
        ::= { docsIfCmtsStatusEntry 6 }



Raftus & Cardona            Standards Track                    [Page 72]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   --
   -- CM status table (within CMTS).
   -- This table is implemented only at the CMTS.
   -- It contains per-CM status information available in the CMTS.
   --

   docsIfCmtsCmStatusTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsCmStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A set of objects in the CMTS, maintained for each
             cable modem connected to this CMTS."
        ::= { docsIfCmtsObjects 3 }

   docsIfCmtsCmStatusEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsCmStatusEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Status information for a single cable modem.
             An entry in this table exists for each cable modem
             that is connected to the CMTS implementing this table."
        INDEX { docsIfCmtsCmStatusIndex }
        ::= { docsIfCmtsCmStatusTable 1 }

   DocsIfCmtsCmStatusEntry ::= SEQUENCE {
            docsIfCmtsCmStatusIndex               Integer32,
            docsIfCmtsCmStatusMacAddress          MacAddress,
            docsIfCmtsCmStatusIpAddress        IpAddress, -- deprecated
            docsIfCmtsCmStatusDownChannelIfIndex  InterfaceIndexOrZero,
            docsIfCmtsCmStatusUpChannelIfIndex    InterfaceIndexOrZero,
            docsIfCmtsCmStatusRxPower             TenthdBmV,
            docsIfCmtsCmStatusTimingOffset        Unsigned32,
            docsIfCmtsCmStatusEqualizationData    DocsEqualizerData,
            docsIfCmtsCmStatusValue               INTEGER,
            docsIfCmtsCmStatusUnerroreds          Counter32,
            docsIfCmtsCmStatusCorrecteds          Counter32,
            docsIfCmtsCmStatusUncorrectables      Counter32,
            docsIfCmtsCmStatusSignalNoise         TenthdB,
            docsIfCmtsCmStatusMicroreflections    Integer32,
            docsIfCmtsCmStatusExtUnerroreds       Counter64,
            docsIfCmtsCmStatusExtCorrecteds       Counter64,
            docsIfCmtsCmStatusExtUncorrectables   Counter64,
            docsIfCmtsCmStatusDocsisRegMode       DocsisQosVersion,
            docsIfCmtsCmStatusModulationType      DocsisUpstreamType,
            docsIfCmtsCmStatusInetAddressType     InetAddressType,
            docsIfCmtsCmStatusInetAddress         InetAddress,



Raftus & Cardona            Standards Track                    [Page 73]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmtsCmStatusValueLastUpdate     TimeStamp,
            docsIfCmtsCmStatusHighResolutionTimingOffset Unsigned32
        }

   docsIfCmtsCmStatusIndex OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Index value to uniquely identify an entry in this table.
             For an individual cable modem, this index value SHOULD
             NOT change during CMTS uptime."
        ::= { docsIfCmtsCmStatusEntry 1 }

   docsIfCmtsCmStatusMacAddress OBJECT-TYPE
        SYNTAX      MacAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "MAC address of the cable modem.  If the cable modem has
             multiple MAC addresses, this is the MAC address associated
             with the Cable interface."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 8.2.2."
        ::= { docsIfCmtsCmStatusEntry 2 }

   docsIfCmtsCmStatusIpAddress OBJECT-TYPE
        SYNTAX      IpAddress
        MAX-ACCESS  read-only
        STATUS      deprecated
        DESCRIPTION
            "IP address of this cable modem.  If the cable modem has no
             IP address assigned, or the IP address is unknown, this
             object returns a value of 0.0.0.0.  If the cable modem has
             multiple IP addresses, this object returns the IP address
             associated with the Cable interface.
             This object has been deprecated and replaced by
             docsIfCmtsCmStatusInetAddressType and
             docsIfCmtsCmStatusInetAddress, to enable IPv6 addressing
             in the future."
        ::= { docsIfCmtsCmStatusEntry 3 }

   docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndexOrZero
        MAX-ACCESS  read-only
        STATUS      current



Raftus & Cardona            Standards Track                    [Page 74]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "IfIndex of the downstream channel that this CM is
             connected to.  If the downstream channel is unknown, this
             object returns a value of zero."
        ::= { docsIfCmtsCmStatusEntry 4 }

   docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndexOrZero
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
           "For DOCSIS 2.0, indicates the ifIndex of the logical
            upstream channel (ifType 205) this CM is connected to.
            For DOCSIS 1.x, indicates the ifIndex of the upstream
             channel (ifType 129) this CM is connected to.
             If the upstream channel is unknown, this object
             returns a value of zero."
        ::= { docsIfCmtsCmStatusEntry 5 }

   docsIfCmtsCmStatusRxPower OBJECT-TYPE
        SYNTAX      TenthdBmV
        UNITS       "ThenthdBmV"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The receive power as perceived for upstream data from
             this cable modem.
             If the receive power is unknown, this object returns
             a value of zero."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.18."
        ::= { docsIfCmtsCmStatusEntry 6 }

   docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
        SYNTAX      Unsigned32 (0..4294967295)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "A measure of the current round trip time for this CM.
             Used for timing of CM upstream transmissions to ensure
             synchronized arrivals at the CMTS.  Units are in terms
             of (6.25 microseconds/64).  Returns zero if the value
             is unknown.
             For channels requiring finer resolution, please refer to
             object docsIfCmtsCmStatusHighResolutionTimingOffset."
        REFERENCE



Raftus & Cardona            Standards Track                    [Page 75]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.17."
        ::= { docsIfCmtsCmStatusEntry 7 }

   docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
        SYNTAX      DocsEqualizerData
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Equalization data for this CM, as measured by the CMTS.
             Returns the zero-length OCTET STRING if the value is
             unknown or if there is no equalization data available
             or defined."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Figure 8-23."
        ::= { docsIfCmtsCmStatusEntry 8 }

   docsIfCmtsCmStatusValue OBJECT-TYPE
        SYNTAX      INTEGER {
            other(1),
            ranging(2),
            rangingAborted(3),
            rangingComplete(4),
            ipComplete(5),
            registrationComplete(6),
            accessDenied(7),
            operational(8),
            -- value 8 should not be used
            registeredBPIInitializing(9)
        }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current cable modem connectivity state, as specified
             in the RF Interface Specification.  Returned status
             information is the CM status, as assumed by the CMTS,
             and indicates the following events:
             other(1)
                Any state other than below.
             ranging(2)
                The CMTS has received an Initial Ranging Request
                message from the CM, and the ranging process is not
                yet complete.
             rangingAborted(3)
                The CMTS has sent a Ranging Abort message to the CM.



Raftus & Cardona            Standards Track                    [Page 76]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             rangingComplete(4)
                The CMTS has sent a Ranging Complete message to the CM.
             ipComplete(5)
                The CMTS has received a DHCP reply message and
                forwarded it to the CM.
             registrationComplete(6)
                The CMTS has sent a Registration Response message to
                the CM.
             accessDenied(7)
                The CMTS has sent a Registration Aborted message
                to the CM.
             operational(8)
                Value 8 is considered reserved and should not be defined
                in future revisions of this MIB module to avoid conflict
                with documented implementations that support value 8 to
                indicate operational state after completing the BPI
                initialization process.
             registeredBPIInitializing(9)
                Baseline Privacy (BPI) is enabled and the CMTS is in the
                process of completing BPI initialization.  This state
                MAY last for a significant length of time if failures
                occur during the initialization process.  After
                completion of BPI initialization, the CMTS will report
                registrationComplete(6).
             The CMTS only needs to report states it is able to
             detect."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 11.2."
        ::= { docsIfCmtsCmStatusEntry 9 }

   docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received without error from this cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.4."
        ::= { docsIfCmtsCmStatusEntry 10 }



Raftus & Cardona            Standards Track                    [Page 77]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received with correctable errors from this
             cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.4."
        ::= { docsIfCmtsCmStatusEntry 11 }

   docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received with uncorrectable errors from this
             cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.4."
        ::= { docsIfCmtsCmStatusEntry 12 }

   docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
        SYNTAX      TenthdB
        UNITS       "TenthdB"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Signal/Noise ratio as perceived for upstream data from
             this cable modem.
             If the Signal/Noise is unknown, this object returns
             a value of zero."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio



Raftus & Cardona            Standards Track                    [Page 78]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 4-1 and 4-2."
        ::= { docsIfCmtsCmStatusEntry 13 }

   docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        UNITS       "-dBc"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total microreflections, including in-channel response
             as perceived on this interface, measured in dBc below
             the signal level.
             This object is not assumed to return an absolutely
             accurate value, but it gives a rough indication
             of microreflections received on this interface.
             It is up to the implementer to provide information
             as accurately as possible.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 4-1 and 4-2"
        ::= { docsIfCmtsCmStatusEntry 14 }

   docsIfCmtsCmStatusExtUnerroreds OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received without error from this cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.5."
        ::= { docsIfCmtsCmStatusEntry 15 }

   docsIfCmtsCmStatusExtCorrecteds OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"



Raftus & Cardona            Standards Track                    [Page 79]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received with correctable errors from this
             cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.5."
        ::= { docsIfCmtsCmStatusEntry 16 }

   docsIfCmtsCmStatusExtUncorrectables OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "codewords"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Codewords received with uncorrectable errors from this
             cable modem.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.5."
        ::= { docsIfCmtsCmStatusEntry 17 }

   docsIfCmtsCmStatusDocsisRegMode OBJECT-TYPE
           SYNTAX      DocsisQosVersion
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "Indication of whether the CM has registered using 1.0
                Class of Service or 1.1 Quality of Service."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Annex G."
        ::= { docsIfCmtsCmStatusEntry 18 }

   docsIfCmtsCmStatusModulationType OBJECT-TYPE
         SYNTAX      DocsisUpstreamType



Raftus & Cardona            Standards Track                    [Page 80]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Indicates modulation type currently used by the CM.  Since
              this object specifically identifies PHY mode, the shared
              type is not permitted.  If the upstream channel is
              unknown, this object returns a value of zero."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-19."
         ::= { docsIfCmtsCmStatusEntry 19 }

   docsIfCmtsCmStatusInetAddressType OBJECT-TYPE
           SYNTAX      InetAddressType
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "The type of internet address of
                docsIfCmtsCmStatusInetAddress.  If the cable modem
                internet address is unassigned or unknown, then the
                value of this object is unknown(0)."
           ::= { docsIfCmtsCmStatusEntry 20 }

   docsIfCmtsCmStatusInetAddress OBJECT-TYPE
           SYNTAX      InetAddress
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "Internet address of this cable modem.  If the Cable
                Modem has no Internet address assigned, or the Internet
                address is unknown, the value of this object is the
                zero-length OCTET STRING.  If the cable modem has
                multiple Internet addresses, this object returns the
                Internet address associated with the Cable
                (i.e., RF MAC) interface."
           ::= { docsIfCmtsCmStatusEntry 21 }

   docsIfCmtsCmStatusValueLastUpdate OBJECT-TYPE
           SYNTAX      TimeStamp
           MAX-ACCESS  read-only
           STATUS      current
           DESCRIPTION
               "The value of sysUpTime when docsIfCmtsCmStatusValue
                was last updated."
           ::= { docsIfCmtsCmStatusEntry 22 }

   docsIfCmtsCmStatusHighResolutionTimingOffset OBJECT-TYPE



Raftus & Cardona            Standards Track                    [Page 81]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        SYNTAX      Unsigned32 (0..4294967295)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "A measure of the current round trip time for this CM.
             Used for timing of CM upstream transmissions to ensure
             synchronized arrivals at the CMTS.  Units are in terms
             of (6.25 microseconds/(64*256)).  Returns zero if the value
             is unknown.
             This is the high resolution version of object
             docsIfCmtsCmStatusTimingOffset, for channels requiring
             finer resolution."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Section 6.2.17."
        ::= { docsIfCmtsCmStatusEntry 23 }

   --
   -- The CMTS Service Table.
   --

   docsIfCmtsServiceTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsServiceEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes of upstream service queues
             in a Cable Modem Termination System."
        ::= { docsIfCmtsObjects 4 }

   docsIfCmtsServiceEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsServiceEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes the attributes of a single upstream bandwidth
             service queue.
             Entries in this table exist for each ifEntry with an
             ifType of docsCableMaclayer(127), and for each service
             queue (Service ID) within this MAC layer.
             Entries in this table are created with the creation of
             individual Service IDs by the MAC layer and removed
             when a Service ID is removed."
        INDEX { ifIndex, docsIfCmtsServiceId }
        ::= { docsIfCmtsServiceTable 1 }

   DocsIfCmtsServiceEntry ::= SEQUENCE {



Raftus & Cardona            Standards Track                    [Page 82]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmtsServiceId               Integer32,
            docsIfCmtsServiceCmStatusIndex    Integer32,  -- deprecated
            docsIfCmtsServiceAdminStatus      INTEGER,
            docsIfCmtsServiceQosProfile       Integer32,
            docsIfCmtsServiceCreateTime       TimeStamp,
            docsIfCmtsServiceInOctets         Counter32,
            docsIfCmtsServiceInPackets        Counter32,
            docsIfCmtsServiceNewCmStatusIndex Integer32
        }

   docsIfCmtsServiceId OBJECT-TYPE
        SYNTAX      Integer32 (1..16383)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Identifies a service queue for upstream bandwidth.  The
             attributes of this service queue are shared between the
             Cable Modem and the Cable Modem Termination System.
             The CMTS allocates upstream bandwidth to this service
             queue based on requests from the CM and on the class of
             service associated with this queue."
        ::= { docsIfCmtsServiceEntry 1 }

   docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      deprecated
        DESCRIPTION
            "Pointer to an entry in docsIfCmtsCmStatusTable identifying
             the cable modem using this Service Queue.  If multiple
             cable modems are using this Service Queue, the value of
             this object is zero.
             This object has been deprecated and replaced by
             docsIfCmtsServiceNewCmStatusIndex, to fix a mismatch
             of the value range with respect to docsIfCmtsCmStatusIndex
             (1..2147483647)."
        ::= { docsIfCmtsServiceEntry 2 }

   docsIfCmtsServiceAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
            enabled(1),
            disabled(2),
            destroyed(3) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Allows a service class for a particular modem to be
             suppressed, (re-)enabled, or deleted altogether."



Raftus & Cardona            Standards Track                    [Page 83]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        ::= { docsIfCmtsServiceEntry 3 }

   docsIfCmtsServiceQosProfile OBJECT-TYPE
        SYNTAX      Integer32 (0..16383)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The index in docsIfQosProfileTable describing the quality
             of service attributes associated with this particular
             service.  If no associated docsIfQosProfileTable entry
             exists, this object returns a value of zero."
        ::= { docsIfCmtsServiceEntry 4 }

   docsIfCmtsServiceCreateTime OBJECT-TYPE
        SYNTAX      TimeStamp
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The value of sysUpTime when this entry was created."
        ::= { docsIfCmtsServiceEntry 5 }

   docsIfCmtsServiceInOctets OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "Bytes"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The cumulative number of Packet Data octets received
             on this Service ID.  The count does not include the
             size of the Cable MAC header.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsServiceEntry 6 }

   docsIfCmtsServiceInPackets OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "packets"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The cumulative number of Packet Data packets received
             on this Service ID.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."



Raftus & Cardona            Standards Track                    [Page 84]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        ::= { docsIfCmtsServiceEntry 7 }

   docsIfCmtsServiceNewCmStatusIndex OBJECT-TYPE
        SYNTAX      Integer32 (0..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Pointer (via docsIfCmtsCmStatusIndex) to an entry in
             docsIfCmtsCmStatusTable identifying the cable modem
             using this Service Queue.  If multiple cable modems are
             using this Service Queue, the value of this object is
             zero."
        ::= { docsIfCmtsServiceEntry 8 }

   --
   -- The following table provides upstream channel modulation profiles.
   -- Entries in this table can be
   -- re-used by one or more upstream channels.  An upstream channel
   -- will have a modulation profile for each value of
   -- docsIfModIntervalUsageCode.
   --

   docsIfCmtsModulationTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsModulationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes a modulation profile associated with one or more
             upstream channels."
        ::= { docsIfCmtsObjects 5 }

   docsIfCmtsModulationEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsModulationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Describes a modulation profile for an Interval Usage Code
             for one or more upstream channels.
             Entries in this table are created by the operator.

             Initial default entries MAY be created at system
             initialization time, which could report a value of
             'permanent' or 'readOnly' for docsIfCmtsModStorageType.
             A CMTS MAY reject the creation of additional Interval
             Usage Codes for a modulation profile being defined at
             Initialization time.
             No individual objects have to be specified in order
             to create an entry in this table.



Raftus & Cardona            Standards Track                    [Page 85]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Note that some objects do not have DEFVAL clauses
             but do have calculated defaults and need not be specified
             during row creation."
         INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode}
        ::= { docsIfCmtsModulationTable 1 }

   DocsIfCmtsModulationEntry ::= SEQUENCE {
            docsIfCmtsModIndex                    Integer32,
            docsIfCmtsModIntervalUsageCode        INTEGER,
            docsIfCmtsModControl                  RowStatus,
            docsIfCmtsModType                     INTEGER,
            docsIfCmtsModPreambleLen              Integer32,
            docsIfCmtsModDifferentialEncoding     TruthValue,
            docsIfCmtsModFECErrorCorrection       Integer32,
            docsIfCmtsModFECCodewordLength        Integer32,
            docsIfCmtsModScramblerSeed            Integer32,
            docsIfCmtsModMaxBurstSize             Integer32,
            docsIfCmtsModGuardTimeSize            Unsigned32,
            docsIfCmtsModLastCodewordShortened    TruthValue,
            docsIfCmtsModScrambler                TruthValue,
            docsIfCmtsModByteInterleaverDepth     Unsigned32,
            docsIfCmtsModByteInterleaverBlockSize Unsigned32,
            docsIfCmtsModPreambleType             INTEGER,
            docsIfCmtsModTcmErrorCorrectionOn     TruthValue,
            docsIfCmtsModScdmaInterleaverStepSize Unsigned32,
            docsIfCmtsModScdmaSpreaderEnable      TruthValue,
            docsIfCmtsModScdmaSubframeCodes       Unsigned32,
            docsIfCmtsModChannelType              DocsisUpstreamType,
            docsIfCmtsModStorageType              StorageType
        }

   docsIfCmtsModIndex OBJECT-TYPE
        SYNTAX       Integer32 (1..2147483647)
        MAX-ACCESS   not-accessible
        STATUS      current
        DESCRIPTION
             "An index into the Channel Modulation table representing
              a group of Interval Usage Codes, all associated with the
              same channel."
        ::= { docsIfCmtsModulationEntry 1 }

   docsIfCmtsModIntervalUsageCode OBJECT-TYPE
        SYNTAX       INTEGER {
            request(1),
            requestData(2),
            initialRanging(3),
            periodicRanging(4),
            shortData(5),



Raftus & Cardona            Standards Track                    [Page 86]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            longData(6),
            advPhyShortData(9),
            advPhyLongData(10),
            ugs(11)
        }
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the Channel Modulation table that, when
             grouped with other Interval Usage Codes, fully
             instantiates all modulation sets for a given upstream
             channel."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-20."
        ::= { docsIfCmtsModulationEntry 2 }

   docsIfCmtsModControl OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Controls and reflects the status of rows in this table.
             There is no restriction on the changing of values in this
             table while their associated rows are active, with the
             exception of:

             1. If a modulation profile is being referenced by one
                or more upstream channels, an attempt to set the value
                of docsIfCmtsModChannelType returns an
                'inconsistentValue' error.

             2. If a modulation profile is being referenced by one
                or more upstream channels, an attempt to set
                docsIfCmtsModControl to destroy(6) or notInService(2)
                returns an 'inconsistentValue' error."
        ::= { docsIfCmtsModulationEntry 3 }

   docsIfCmtsModType OBJECT-TYPE
        SYNTAX      INTEGER {
            other(1),
            qpsk(2),
            qam16(3),
            qam8(4),
            qam32(5),
            qam64(6),
            qam128(7)



Raftus & Cardona            Standards Track                    [Page 87]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The modulation type used on this channel.  Returns
             other(1) if the modulation type is not
             qpsk, qam16, qam8, qam32, qam64, or qam128.
             Type qam128 is used for SCDMA channels only.
             See the reference for the modulation profiles
             implied by different modulation types."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { qpsk }
        ::= { docsIfCmtsModulationEntry 4 }

   docsIfCmtsModPreambleLen OBJECT-TYPE
        SYNTAX      Integer32 (0..1536)
        UNITS       "bits"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The preamble length for this modulation profile in bits.
             Default value is the minimum needed by the implementation
             at the CMTS for the given modulation profile."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        ::= { docsIfCmtsModulationEntry 5 }

   docsIfCmtsModDifferentialEncoding OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Specifies whether or not differential encoding is used
             on this channel."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { false }
        ::= { docsIfCmtsModulationEntry 6 }

   docsIfCmtsModFECErrorCorrection OBJECT-TYPE
        SYNTAX      Integer32 (0..16)



Raftus & Cardona            Standards Track                    [Page 88]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        UNITS       "Bytes"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The number of correctable errored bytes (t) used in
             forward error correction code.  The value of 0 indicates
             that no correction is employed.  The number of check bytes
             appended will be twice this value."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { 0 }
        ::= { docsIfCmtsModulationEntry 7 }

   docsIfCmtsModFECCodewordLength OBJECT-TYPE
        SYNTAX      Integer32 (1..255)
        UNITS       "Bytes"
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The number of data bytes (k) in the forward error
             correction codeword.
             This object is not used if docsIfCmtsModFECErrorCorrection
             is zero."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { 32 }
        ::= { docsIfCmtsModulationEntry 8 }

   docsIfCmtsModScramblerSeed OBJECT-TYPE
        SYNTAX      Integer32 (0..32767)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The 15-bit seed value for the scrambler polynomial."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-19."
        DEFVAL { 0 }
        ::= { docsIfCmtsModulationEntry 9 }

   docsIfCmtsModMaxBurstSize OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        UNITS       "mini-slots"



Raftus & Cardona            Standards Track                    [Page 89]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The maximum number of mini-slots that can be transmitted
             during this channel's burst time.  Returns zero if the
             burst length is bounded by the allocation MAP rather than
             by this profile.
             Default value is 0, except for shortData, where it is 8."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-19."
        ::= { docsIfCmtsModulationEntry 10 }

   docsIfCmtsModGuardTimeSize OBJECT-TYPE
        SYNTAX      Unsigned32
        UNITS       "Symbol-times"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The number of symbol-times that MUST follow the end of
             this channel's burst.  Default value is the minimum time
             needed by the implementation for this modulation profile."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        ::= { docsIfCmtsModulationEntry 11 }

   docsIfCmtsModLastCodewordShortened OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Indicates whether the last FEC codeword is truncated."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { true }
        ::= { docsIfCmtsModulationEntry 12 }

   docsIfCmtsModScrambler OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Indicates whether the scrambler is employed."



Raftus & Cardona            Standards Track                    [Page 90]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { false }
        ::= { docsIfCmtsModulationEntry 13 }

   docsIfCmtsModByteInterleaverDepth OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "ATDMA Byte Interleaver Depth (Ir).  This object returns 1
             for non-ATDMA profiles."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { 1 }
        ::= { docsIfCmtsModulationEntry 14 }

   docsIfCmtsModByteInterleaverBlockSize OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "ATDMA Byte Interleaver Block size (Br).  This object
             returns zero for non-ATDMA profiles "
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { 18 }
        ::= { docsIfCmtsModulationEntry 15 }

   docsIfCmtsModPreambleType OBJECT-TYPE
        SYNTAX       INTEGER {
            unknown(0),
            qpsk0(1),
            qpsk1(2)
        }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Preamble type for DOCSIS 2.0 bursts.  The value
             'unknown(0)' represents a row entry consisting only of
             DOCSIS 1.x bursts"
        REFERENCE



Raftus & Cardona            Standards Track                    [Page 91]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { qpsk0 }
        ::= { docsIfCmtsModulationEntry 16 }

   docsIfCmtsModTcmErrorCorrectionOn OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Trellis Code Modulation (TCM) On/Off.  This value returns
             false for non-S-CDMA profiles."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { false }
        ::= { docsIfCmtsModulationEntry 17 }

   docsIfCmtsModScdmaInterleaverStepSize OBJECT-TYPE
        SYNTAX      Unsigned32 (0 | 1..32)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            " S-CDMA Interleaver step size.  This value returns zero
              for non-S-CDMA profiles."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        DEFVAL { 1 }
        ::= { docsIfCmtsModulationEntry 18 }

   docsIfCmtsModScdmaSpreaderEnable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            " S-CDMA spreader.  This value returns false for non-S-CDMA
              profiles.  Default value for IUC 3 and 4 is OFF; for
              all other IUCs it is ON."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Tables 6-7, and 8-19."
        ::= { docsIfCmtsModulationEntry 19 }




Raftus & Cardona            Standards Track                    [Page 92]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfCmtsModScdmaSubframeCodes OBJECT-TYPE
        SYNTAX      Unsigned32 (0 | 1..128)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            " S-CDMA sub-frame size.  This value returns zero
              for non-S-CDMA profiles."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 6-7, and 8-19."
        DEFVAL { 1 }
        ::= { docsIfCmtsModulationEntry 20 }

   docsIfCmtsModChannelType OBJECT-TYPE
        SYNTAX      DocsisUpstreamType
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Describes the modulation channel type for this modulation
             entry.
             All the active entries in a modulation profile (that is all
             active entries that share a common docsIfCmtsModIndex)
             MUST have the same value of docsIfCmtsModChannelType."
        REFERENCE
            "Data-Over-Cable Service Interface Specifications: Radio
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
             Table 8-19."
        DEFVAL { tdma }
        ::= { docsIfCmtsModulationEntry 21 }

   docsIfCmtsModStorageType OBJECT-TYPE
        SYNTAX       StorageType
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
            "The storage type for this conceptual row.
             Entries with this object set to permanent(4)
             do not require write operations for read-write
             objects."
        DEFVAL      { nonVolatile }
    ::= { docsIfCmtsModulationEntry 22 }

   docsIfCmtsQosProfilePermissions OBJECT-TYPE
        SYNTAX      BITS {
            createByManagement(0),
            updateByManagement(1),
            createByModems(2)



Raftus & Cardona            Standards Track                    [Page 93]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object specifies permitted methods of creating
             entries in docsIfQosProfileTable.
             createByManagement(0) is set if entries can be created
             using SNMP.  updateByManagement(1) is set if updating
             entries using SNMP is permitted.  createByModems(2)
             is set if entries can be created based on information
             in REG-REQ MAC messages received from cable modems.
             Information in this object is only applicable if
             docsIfQosProfileTable is implemented as read-create.
             Otherwise, this object is implemented as read-only
             and returns createByModems(2).
             Either createByManagement(0) or updateByManagement(1)
             MUST be set when writing to this object.
             Note that BITS objects are encoded most significant bit
             first.  For example, if bit 2 is set, the value of this
             object is the octet string '20'H."
        ::= { docsIfCmtsObjects 6 }

   docsIfCmtsMacToCmTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsMacToCmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This is a table to provide a quick access index into the
             docsIfCmtsCmStatusTable.  There is exactly one row in this
             table for each row in the docsIfCmtsCmStatusTable.  In
             general, the management station SHOULD use this table only
             to get a pointer into the docsIfCmtsCmStatusTable (which
             corresponds to the CM's RF interface MAC address) and
             SHOULD not iterate (e.g., GetNext through) this table."
        ::= { docsIfCmtsObjects 7 }

   docsIfCmtsMacToCmEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsMacToCmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A row in the docsIfCmtsMacToCmTable.
             An entry in this table exists for each cable modem
             that is connected to the CMTS implementing this table."
        INDEX   { docsIfCmtsCmMac }
        ::= {docsIfCmtsMacToCmTable 1 }

   DocsIfCmtsMacToCmEntry ::= SEQUENCE {



Raftus & Cardona            Standards Track                    [Page 94]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


                docsIfCmtsCmMac     MacAddress,
                docsIfCmtsCmPtr     Integer32
        }

   docsIfCmtsCmMac OBJECT-TYPE
        SYNTAX      MacAddress
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The RF side MAC address for the referenced CM (e.g., the
             interface on the CM that has docsCableMacLayer(127) as
             its ifType)."
        ::= { docsIfCmtsMacToCmEntry 1 }

   docsIfCmtsCmPtr OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An row index into docsIfCmtsCmStatusTable.  When queried
             with the correct instance value (e.g., a CM's MAC address),
             returns the index in docsIfCmtsCmStatusTable that
             represents that CM."
        ::= { docsIfCmtsMacToCmEntry 2 }

   -- The following independent object and associated table provide
   -- operators with a mechanism to evaluate the load/utilization of
   -- both upstream and downstream physical channels.  This information
   -- may be used for capacity planning and incident analysis and may
   -- be particularly helpful in provisioning of high value QOS.
   --
   -- Utilization is expressed as an index representing the calculated
   -- percentage utilization of the upstream or downstream channel in
   -- the most recent sampling interval (i.e., utilization interval).
   -- Refer to the DESCRIPTION field of the
   -- docsIfCmtsChannelUtUtilization object for definitions and
   -- calculation details.

   docsIfCmtsChannelUtilizationInterval OBJECT-TYPE
        SYNTAX      Integer32 (0..86400)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The time interval in seconds over which the channel
             utilization index is calculated.  All upstream/downstream
             channels use the same
             docsIfCmtsChannelUtilizationInterval.



Raftus & Cardona            Standards Track                    [Page 95]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             Setting a value of zero disables utilization reporting.
             A channel utilization index is calculated over a fixed
             window applying to the most recent
             docsIfCmtsChannelUtilizationInterval.  It would therefore
             be prudent to use a relatively short
             docsIfCmtsChannelUtilizationInterval.
             It is a vendor decision whether to reset the timer when
             docsIfCmtsChannelUtilizationInterval is changed during a
             utilization sampling period."
        ::= { docsIfCmtsObjects 8 }

   docsIfCmtsChannelUtilizationTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsChannelUtilizationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Reports utilization statistics for attached upstream and
             downstream physical channels."
        ::= { docsIfCmtsObjects 9 }

   docsIfCmtsChannelUtilizationEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsChannelUtilizationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Utilization statistics for a single upstream or downstream
             physical channel.  An entry exists in this table for each
             ifEntry with an ifType equal to
             docsCableDownstream (128)
             or docsCableUpstream (129)."
        INDEX  { ifIndex, docsIfCmtsChannelUtIfType,
             docsIfCmtsChannelUtId }
        ::= { docsIfCmtsChannelUtilizationTable 1 }

   DocsIfCmtsChannelUtilizationEntry ::= SEQUENCE {
            docsIfCmtsChannelUtIfType         IANAifType,
            docsIfCmtsChannelUtId             Integer32,
            docsIfCmtsChannelUtUtilization    Integer32
        }

   docsIfCmtsChannelUtIfType OBJECT-TYPE
        SYNTAX       IANAifType
        MAX-ACCESS   not-accessible
        STATUS       current
        DESCRIPTION
            "The secondary index into this table.  Indicates the IANA
             interface type associated with this physical channel.
             Only docsCableDownstream (128) and



Raftus & Cardona            Standards Track                    [Page 96]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             docsCableUpstream (129) are valid."
        ::= { docsIfCmtsChannelUtilizationEntry 1 }

   docsIfCmtsChannelUtId OBJECT-TYPE
        SYNTAX       Integer32 (0..255)
        MAX-ACCESS   not-accessible
        STATUS       current
        DESCRIPTION
             "The tertiary index into this table.  Indicates the CMTS
              identifier for this physical channel."
        ::= { docsIfCmtsChannelUtilizationEntry 2 }

   docsIfCmtsChannelUtUtilization OBJECT-TYPE
        SYNTAX       Integer32 (0..100)
        UNITS        "percent"
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
            "The calculated and truncated utilization index for this
             physical upstream or downstream channel, accurate as of
             the most recent docsIfCmtsChannelUtilizationInterval.

             Upstream Channel Utilization Index:

             The upstream channel utilization index is expressed as a
             percentage of mini-slots utilized on the physical channel,
             regardless of burst type.  For an Initial Maintenance
             region, the mini-slots for the complete region are
             considered utilized if the CMTS received an upstream
             burst within the region from any CM on the physical
             channel.  For contention REQ and REQ/DATA regions, the
             mini-slots for a transmission opportunity within the
             region are considered utilized if the CMTS received an
             upstream burst within the opportunity from any CM on the
             physical channel.  For all other regions, utilized
             mini-slots are those in which the CMTS granted
             bandwidth to any unicast SID on the physical channel.

             For an upstream interface that has multiple logical
             upstream channels enabled, the utilization index is a
             weighted sum of utilization indices for the logical
             channels.  The weight for each utilization index is the
             percentage of upstream mini-slots allocated for the
             corresponding logical channel.
             Example:
             If 75% of bandwidth is allocated to the first logical
             channel and 25% to the second, and the utilization
             indices for each are 60 and 40, respectively, the



Raftus & Cardona            Standards Track                    [Page 97]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             utilization index for the upstream physical channel is
             (60 * 0.75) + (40 * 0.25) = 55.  This figure
             applies to the most recent utilization interval.

             Downstream Channel Utilization Index:

             The downstream channel utilization index is a percentage
             expressing the ratio between bytes used to transmit data
             versus the total number of bytes transmitted in the raw
             bandwidth of the MPEG channel.  As with the upstream
             utilization index, the calculated value represents
             the most recent utilization interval.
             Formula:
             Downstream utilization index =
             (100 * (data bytes / raw bytes))

             Definitions:
             Data bytes:    Number of bytes transmitted as data in the
                            docsIfCmtsChannelUtilizationInterval.
                            Identical to docsIfCmtsDownChannelCtrUsed
                            Bytes measured over the utilization
                            interval.
             Raw bandwidth: Total number of bytes available for
                            transmitting data, not including bytes
                            used for headers and other overhead.
             Raw bytes:     (raw bandwidth *
                            docsIfCmtsChannelUtilizationInterval).
                            Identical to docsIfCmtsDownChannelCtrTotal
                            Bytes measured over the utilization
                            interval."
        ::= { docsIfCmtsChannelUtilizationEntry 3 }

   -- The following table provides operators with input data
   -- appropriate for calculating downstream channel utilization.
   -- Operators may use the docsIfCmtsChannelUtilizationTable or
   -- perform their own polling of the
   -- docsIfCmtsDownChannelCounterTable objects to characterize
   -- their downstream channel usage.  The 32-bit counter objects are
   -- included to provide backward compatibility with SNMPv1 managers,
   -- which cannot access 64-bit counter objects.

   docsIfCmtsDownChannelCounterTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsDownChannelCounterEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table is implemented at the CMTS to collect
             downstream channel statistics for utilization



Raftus & Cardona            Standards Track                    [Page 98]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             calculations."
        ::= { docsIfCmtsObjects 10 }

   docsIfCmtsDownChannelCounterEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsDownChannelCounterEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry provides a list of traffic counters for a single
             downstream channel.
             An entry in this table exists for each ifEntry with an
             ifType of docsCableDownstream(128)."
        INDEX { ifIndex }
        ::= { docsIfCmtsDownChannelCounterTable 1 }

   DocsIfCmtsDownChannelCounterEntry ::= SEQUENCE {
            docsIfCmtsDownChnlCtrId              Integer32,
            docsIfCmtsDownChnlCtrTotalBytes      Counter32,
            docsIfCmtsDownChnlCtrUsedBytes       Counter32,
            docsIfCmtsDownChnlCtrExtTotalBytes   Counter64,
            docsIfCmtsDownChnlCtrExtUsedBytes    Counter64
        }

   docsIfCmtsDownChnlCtrId OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The Cable Modem Termination System identification
             of the downstream channel within this particular MAC
             interface.  If the interface is down, the object returns
             the most current value.  If the downstream channel ID is
             unknown, this object returns a value of 0."
        ::= { docsIfCmtsDownChannelCounterEntry 1 }

   docsIfCmtsDownChnlCtrTotalBytes OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "Bytes"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "At the CMTS, the total number of bytes in the Payload
             portion of MPEG Packets (i.e., not including MPEG header
             or pointer_field) transported by this downstream channel.
             This is the 32-bit version of
             docsIfCmtsDownChnlCtrExtTotalBytes, included to provide
             back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur



Raftus & Cardona            Standards Track                    [Page 99]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsDownChannelCounterEntry 2 }

   docsIfCmtsDownChnlCtrUsedBytes OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "Bytes"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "At the CMTS, the total number of DOCSIS data bytes
             transported by this downstream channel.
             The number of data bytes is defined as the total number
             of bytes transported in DOCSIS payloads minus the number
             of stuff bytes transported in DOCSIS payloads.
             This is the 32-bit version of
             docsIfCmtsDownChnlCtrExtUsedBytes, included to provide
             back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsDownChannelCounterEntry 3 }

   docsIfCmtsDownChnlCtrExtTotalBytes OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "Bytes"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "At the CMTS, the total number of bytes in the Payload
             portion of MPEG Packets (i.e., not including MPEG header
             or pointer_field) transported by this downstream
             channel.
             This is the 64-bit version of
             docsIfCmtsDownChnlCtrTotalBytes and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsDownChannelCounterEntry 4 }

   docsIfCmtsDownChnlCtrExtUsedBytes OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "Bytes"
        MAX-ACCESS  read-only



Raftus & Cardona            Standards Track                   [Page 100]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        STATUS      current
        DESCRIPTION
            "At the CMTS, the total number of DOCSIS data bytes
             transported by this downstream channel.  The number
             of data bytes is defined as the total number of bytes
             transported in DOCSIS payloads minus the number of
             stuff bytes transported in DOCSIS payloads.
             This is the 64-bit version of
             docsIfCmtsDownChnlCtrUsedBytes and will not be accessible
             to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsDownChannelCounterEntry 5 }

   -- The following table provides operators with input data appropriate
   -- for calculating upstream channel utilization, and for determining
   -- the traffic characteristics of upstream channels.  Operators may
   -- use the docsIfCmtsChannelUtilizationTable or perform their own
   -- polling of the docsIfCmtsUpChannelCounterTable objects for
   -- utilization determination.
   -- The first four 32 and 64 objects in this table are mandatory.
   -- Vendors may choose to implement the remaining optional objects to
   -- provide operators with finer characterization of upstream channel
   -- traffic patterns.  The 32-bit counter objects are included to
   -- provide backward compatibility with SNMPv1 managers, which cannot
   -- access 64-bit counter objects.

   docsIfCmtsUpChannelCounterTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF DocsIfCmtsUpChannelCounterEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table is implemented at the CMTS to provide upstream
             channel statistics appropriate for channel utilization
             calculations."
        ::= { docsIfCmtsObjects 11 }

   docsIfCmtsUpChannelCounterEntry OBJECT-TYPE
        SYNTAX      DocsIfCmtsUpChannelCounterEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "List of traffic statistics for a single upstream channel.
             For DOCSIS 2.0 CMTSs, an entry in this table
             exists for each ifEntry with an ifType of
             docsCableUpstreamChannel (205).



Raftus & Cardona            Standards Track                   [Page 101]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             For DOCSIS 1.x CMTSs, an entry in this table
             exists for each ifEntry with an ifType of
             docsCableUpstream (129)."
        INDEX { ifIndex }
        ::= { docsIfCmtsUpChannelCounterTable 1 }

   DocsIfCmtsUpChannelCounterEntry ::= SEQUENCE {
            docsIfCmtsUpChnlCtrId                          Integer32,
            docsIfCmtsUpChnlCtrTotalMslots                 Counter32,
            docsIfCmtsUpChnlCtrUcastGrantedMslots          Counter32,
            docsIfCmtsUpChnlCtrTotalCntnMslots             Counter32,
            docsIfCmtsUpChnlCtrUsedCntnMslots              Counter32,
            docsIfCmtsUpChnlCtrExtTotalMslots              Counter64,
            docsIfCmtsUpChnlCtrExtUcastGrantedMslots       Counter64,
            docsIfCmtsUpChnlCtrExtTotalCntnMslots          Counter64,
            docsIfCmtsUpChnlCtrExtUsedCntnMslots           Counter64,
            docsIfCmtsUpChnlCtrCollCntnMslots              Counter32,
            docsIfCmtsUpChnlCtrTotalCntnReqMslots          Counter32,
            docsIfCmtsUpChnlCtrUsedCntnReqMslots           Counter32,
            docsIfCmtsUpChnlCtrCollCntnReqMslots           Counter32,
            docsIfCmtsUpChnlCtrTotalCntnReqDataMslots      Counter32,
            docsIfCmtsUpChnlCtrUsedCntnReqDataMslots       Counter32,
            docsIfCmtsUpChnlCtrCollCntnReqDataMslots       Counter32,
            docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots    Counter32,
            docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots     Counter32,
            docsIfCmtsUpChnlCtrCollCntnInitMaintMslots     Counter32,
            docsIfCmtsUpChnlCtrExtCollCntnMslots           Counter64,
            docsIfCmtsUpChnlCtrExtTotalCntnReqMslots       Counter64,
            docsIfCmtsUpChnlCtrExtUsedCntnReqMslots        Counter64,
            docsIfCmtsUpChnlCtrExtCollCntnReqMslots        Counter64,
            docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots   Counter64,
            docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots    Counter64,
            docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots    Counter64,
            docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots Counter64,
            docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots  Counter64,
            docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots  Counter64
        }

   docsIfCmtsUpChnlCtrId OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The CMTS identification of the upstream channel."
        ::= { docsIfCmtsUpChannelCounterEntry 1 }

   docsIfCmtsUpChnlCtrTotalMslots OBJECT-TYPE
        SYNTAX      Counter32



Raftus & Cardona            Standards Track                   [Page 102]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of all mini-slots
             defined for this upstream logical channel.  This count
             includes all IUCs and SIDs, even those allocated to the
             NULL SID for a 2.0 logical channel that is inactive.  This
             is the 32-bit version of docsIfCmtsUpChnlCtrExtTotalMslots
             and is included for back compatibility with SNMPv1
             managers.  Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 2 }

   docsIfCmtsUpChnlCtrUcastGrantedMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of unicast
             granted mini-slots on the upstream logical channel,
             regardless of burst type.  Unicast granted mini-slots are
             those in which the CMTS assigned bandwidth to any unicast
             SID on the logical channel.  However, this object does not
             include minis-lots for reserved IUCs, or grants to SIDs
             designated as meaning 'no CM'.  This is the 32-bit version
             of docsIfCmtsUpChnlCtrExtUcastGrantedMslots, and is
             included for back compatibility with SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 3 }

   docsIfCmtsUpChnlCtrTotalCntnMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             mini-slots defined for this upstream logical channel.  This
             count includes all mini-slots assigned to a broadcast or



Raftus & Cardona            Standards Track                   [Page 103]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             multicast SID on the logical channel.  This is the 32-bit
             version of docsIfCmtsUpChnlCtrExtTotalCntnMslots, and is
             included for back compatibility with SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 4 }

   docsIfCmtsUpChnlCtrUsedCntnMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             mini-slots utilized on the upstream logical channel.  For
             contention regions, utilized mini-slots are those in which
             the CMTS correctly received an upstream burst from any CM
             on the upstream logical channel.  This is the 32-bit
             version of docsIfCmtsUpChnlCtrExtUsedCntnMslots and is
             included for back compatibility with SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 5 }

   docsIfCmtsUpChnlCtrExtTotalMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of all mini-slots
             defined for this upstream logical channel.  This count
             includes all IUCs and SIDs, even those allocated to the
             NULL SID for a 2.0 logical channel that is inactive.  This
             is the 64-bit version of docsIfCmtsUpChnlCtrTotalMslots
             and will not be accessible to SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 6 }



Raftus & Cardona            Standards Track                   [Page 104]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   docsIfCmtsUpChnlCtrExtUcastGrantedMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of unicast
             granted mini-slots on the upstream logical channel,
             regardless of burst type.  Unicast granted mini-slots are
             those in which the CMTS assigned bandwidth to any unicast
             SID on the logical channel.  However, this object does not
             include mini-slots for reserved IUCs, or grants to SIDs
             designated as meaning 'no CM'.  This is the 64-bit version
             of docsIfCmtsUpChnlCtrUcastGrantedMslots and will not be
             accessible to SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 7 }

   docsIfCmtsUpChnlCtrExtTotalCntnMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             mini-slots defined for this upstream logical channel.  This
             count includes all mini-slots assigned to a broadcast or
             multicast SID on the logical channel.  This is the 64-bit
             version of docsIfCmtsUpChnlCtrTotalCntnMslots and will
             not be accessible to SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 8 }

   docsIfCmtsUpChnlCtrExtUsedCntnMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention



Raftus & Cardona            Standards Track                   [Page 105]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             mini-slots utilized on the upstream logical channel.  For
             contention regions, utilized mini-slots are those in which
             the CMTS correctly received an upstream burst from any CM
             on the upstream logical channel.  This is the 64-bit
             version of docsIfCmtsUpChnlCtrUsedCntnMslots and will not
             be accessible to SNMPv1 managers.
             Support for this object is mandatory.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 9 }

   docsIfCmtsUpChnlCtrCollCntnMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             mini-slots subjected to collisions on the upstream logical
             channel.  For contention regions, these are the mini-slots
             applicable to bursts that the CMTS detected but could not
             correctly receive.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtCollCntnMslots and is included for
             back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 10 }

   docsIfCmtsUpChnlCtrTotalCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots defined for this upstream logical
             channel.  This count includes all mini-slots for IUC1
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtTotalCntnReqMslots and is included
             for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of



Raftus & Cardona            Standards Track                   [Page 106]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 11 }

   docsIfCmtsUpChnlCtrUsedCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots utilized on this upstream logical
             channel.  This count includes all contention mini-slots for
             IUC1 applicable to bursts that the CMTS correctly
             received.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtUsedCntnReqMslots and is included
             for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 12 }

   docsIfCmtsUpChnlCtrCollCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots subjected to collisions on this upstream
             logical channel.  This includes all contention mini-slots
             for IUC1 applicable to bursts that the CMTS detected but
             could not correctly receive.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtCollCntnReqMslots and is included
             for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 13 }

   docsIfCmtsUpChnlCtrTotalCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention



Raftus & Cardona            Standards Track                   [Page 107]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             request data mini-slots defined for this upstream logical
             channel.  This count includes all mini-slots for IUC2
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots and is
             included for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 14 }

   docsIfCmtsUpChnlCtrUsedCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
   MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request data mini-slots utilized on this upstream logical
             channel.  This includes all contention mini-slots for IUC2
             applicable to bursts that the CMTS correctly received.
             This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots and is
             included for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 15 }

   docsIfCmtsUpChnlCtrCollCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request data mini-slots subjected to collisions on this
             upstream logical channel.  This includes all contention
             mini-slots for IUC2 applicable to bursts that the CMTS
             detected, but could not correctly receive.  This is the
             32-bit version of
             docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots and is
             included for back compatibility with SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of



Raftus & Cardona            Standards Track                   [Page 108]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 16 }

   docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             initial maintenance mini-slots defined for this upstream
             logical channel.  This includes all mini-slots for IUC3
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots
             and is included for back compatibility with SNMPv1
             managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 17 }

   docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             initial maintenance mini-slots utilized on this upstream
             logical channel.  This includes all contention mini-slots
             for IUC3 applicable to bursts that the CMTS correctly
             received.  This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots
             and is included for back compatibility with SNMPv1
             managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 18 }

   docsIfCmtsUpChnlCtrCollCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter32
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION



Raftus & Cardona            Standards Track                   [Page 109]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Current count, from CMTS initialization, of contention
             initial maintenance mini-slots subjected to collisions on
             this upstream logical channel.  This includes all
             contention mini-slots for IUC3 applicable to bursts that
             the CMTS detected, but could not correctly receive.
             This is the 32-bit version of
             docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots
             and is included for back compatibility with SNMPv1
             managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 19 }

   docsIfCmtsUpChnlCtrExtCollCntnMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of collision
             contention mini-slots on the upstream logical channel.
             For contention regions, these are the mini-slots applicable
             to bursts that the CMTS detected, but could not correctly
             receive.  This is the 64-bit version of
             docsIfCmtsUpChnlCtrCollCntnMslots and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 20 }

   docsIfCmtsUpChnlCtrExtTotalCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots defined for this upstream logical
             channel.  This count includes all mini-slots for IUC1
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 64-bit version of
             docsIfCmtsUpChnlCtrTotalCntnReqMslots and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur



Raftus & Cardona            Standards Track                   [Page 110]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 21 }

   docsIfCmtsUpChnlCtrExtUsedCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots utilized on this upstream logical
             channel.  This count includes all contention mini-slots for
             IUC1 applicable to bursts that the CMTS correctly
             received.  This is the 64-bit version of
             docsIfCmtsUpChnlCtrUsedCntnReqMslots and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 22 }

   docsIfCmtsUpChnlCtrExtCollCntnReqMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request mini-slots subjected to collisions on this upstream
             logical channel.  This includes all contention mini-slots
             for IUC1 applicable to bursts that the CMTS detected,
             but could not correctly receive.  This is the 64-bit
             version of docsIfCmtsUpChnlCtrCollCntnReqMslots and will
             not be accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 23 }

   docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current



Raftus & Cardona            Standards Track                   [Page 111]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request data mini-slots defined for this upstream logical
             channel.  This count includes all mini-slots for IUC2
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 64-bit version of
             docsIfCmtsUpChnlCtrTotalCntnReqDataMslots and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 24 }

   docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request data mini-slots utilized on this upstream logical
             channel.  This includes all contention mini-slots for IUC2
             applicable to bursts that the CMTS correctly received.
             This is the 64-bit version of
             docsIfCmtsUpChnlCtrUsedCntnReqDataMslots and will not be
             accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 25 }

   docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             request data mini-slots subjected to collisions on this
             upstream logical channel.  This includes all contention
             mini-slots for IUC2 applicable to bursts that the CMTS
             detected, but could not correctly receive.  This is the
             64-bit version of
             docsIfCmtsUpChnlCtrCollCntnReqDataMslots
             and will not be accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur



Raftus & Cardona            Standards Track                   [Page 112]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 26 }

   docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of initial
             maintenance mini-slots defined for this upstream logical
             channel.  This count includes all mini-slots for IUC3
             assigned to a broadcast or multicast SID on the logical
             channel.  This is the 64-bit version of
             docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots
             and will not be accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 27 }

   docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Current count, from CMTS initialization, of initial
             maintenance mini-slots utilized on this upstream logical
             channel.  This includes all contention mini-slots for IUC3
             applicable to bursts that the CMTS correctly received.
             This is the 64-bit version of
             docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots
             and will not be accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 28 }

   docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "mini-slots"
        MAX-ACCESS  read-only
        STATUS      current



Raftus & Cardona            Standards Track                   [Page 113]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "Current count, from CMTS initialization, of contention
             initial maintenance mini-slots subjected to collisions on
             this upstream logical channel.  This includes all
             contention mini-slots for IUC3 applicable to bursts that
             the CMTS detected, but could not correctly receive.
             This is the 64-bit version of
             docsIfCmtsUpChnlCtrCollCntnInitMaintMslots and will not
             be accessible to SNMPv1 managers.
             Discontinuities in the value of this counter can occur
             at reinitialization of the managed system, and at other
             times as indicated by the value of
             ifCounterDiscontinuityTime for the associated ifIndex."
        ::= { docsIfCmtsUpChannelCounterEntry 29 }

   --
   -- notification group is for future extension.
   --

   docsIfNotification OBJECT IDENTIFIER     ::= { docsIfMib 2 }

   --
   -- MIB Compliance statements.
   --

   --
   -- Conformance definitions
   --

   docsIfConformance  OBJECT IDENTIFIER     ::= { docsIfMib 3 }
   docsIfCompliances  OBJECT IDENTIFIER     ::= { docsIfConformance 1 }
   docsIfGroups       OBJECT IDENTIFIER     ::= { docsIfConformance 2 }

   docsIfBasicCompliance MODULE-COMPLIANCE
        STATUS      deprecated
        DESCRIPTION
            "The compliance statement for devices that implement
             DOCSIS 1.x compliant Radio Frequency Interfaces."

   MODULE  -- docsIfMib

   -- unconditionally mandatory groups
   MANDATORY-GROUPS {
        docsIfBasicGroup
        }

   -- conditionally mandatory group
   GROUP docsIfCmGroup



Raftus & Cardona            Standards Track                   [Page 114]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "This group is implemented only in cable modems, not in
             cable modem termination systems."

   -- conditionally mandatory group
   GROUP docsIfCmtsGroup
        DESCRIPTION
            "This group is implemented only in cable modem termination
             systems, not in cable modems."

   OBJECT  docsIfDownChannelFrequency
        WRITE-SYNTAX Integer32 (54000000..860000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems.  The values above are
             appropriate for a cable plant using a Sub-Split channel
             plan.  If DOCSIS is extended to cover other types of
             channel plans (and frequency allocations), this object
             will be modified accordingly."

   OBJECT  docsIfDownChannelWidth
        WRITE-SYNTAX Integer32 (6000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is important to implement this object as read-only.
             In cable modems, this object is always implemented as
             read-only.  The above value is appropriate for cable
             plants running under NTSC (National Television
             Standards Committee) standards.  If DOCSIS is extended to
             work with other standards (e.g., European standards), this
             object will be modified accordingly."

   OBJECT  docsIfDownChannelModulation
        WRITE-SYNTAX INTEGER {
                               qam64 (3),
                               qam256 (4)
                             }
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfDownChannelInterleave
        WRITE-SYNTAX INTEGER {
                    taps8Increment16(3),
                    taps16Increment8(4),
                    taps32Increment4(5),



Raftus & Cardona            Standards Track                   [Page 115]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


                    taps64Increment2(6),
                    taps128Increment1(7)
                     }
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfDownChannelPower
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelFrequency
        WRITE-SYNTAX Integer32 (5000000..42000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems.  The values above are
             appropriate for a cable plant using a Sub-Split channel
             plan.  If DOCSIS is extended to cover other types of
             channel plans (and frequency allocations), this object
             will be modified accordingly."

   OBJECT  docsIfUpChannelWidth
        WRITE-SYNTAX Integer32 (200000..3200000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems.  The above value is appropriate
             for cable plants running under NTSC (National Television
             Standards Committee) standards.  If DOCSIS is extended to
             work with other standards (e.g., European standards), this
             object will be modified accordingly."

   OBJECT  docsIfUpChannelModulationProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelSlotSize
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."



Raftus & Cardona            Standards Track                   [Page 116]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   OBJECT  docsIfUpChannelRangingBackoffStart
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelRangingBackoffEnd
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelTxBackoffStart
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelTxBackoffEnd
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfQosProfPriority
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxUpBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfGuarUpBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxDownBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION



Raftus & Cardona            Standards Track                   [Page 117]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxTxBurst
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfBaselinePrivacy
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfStatus
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfCmtsServiceAdminStatus
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsSyncInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsUcdInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsInsertInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsInvitedRangingAttempts
        MIN-ACCESS  read-only
        DESCRIPTION



Raftus & Cardona            Standards Track                   [Page 118]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsQosProfilePermissions
        WRITE-SYNTAX     BITS {
            createByManagement(0),
            updateByManagement(1)
           }
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT docsIfCmtsModType
        WRITE-SYNTAX INTEGER {
                        qpsk (2),
                        qam16 (3)
                         }
        DESCRIPTION
            "A management station MAY only set 16QAM or QPSK modulation,
             but others might be possible, based on device
             configuration."

   OBJECT  docsIfCmtsModPreambleLen
        SYNTAX Integer32 (0..1024)
        DESCRIPTION
            "The range of the values for this MODULE-COMPLIANCE
             is 0..1024."

   OBJECT  docsIfCmtsModFECErrorCorrection
           SYNTAX Integer32 (0..10)
           DESCRIPTION
               "The range of the values for this MODULE-COMPLIANCE
                is 0..10."

        ::= { docsIfCompliances 1 }

   docsIfBasicComplianceV2 MODULE-COMPLIANCE
        STATUS      current
        DESCRIPTION
            "The compliance statement for devices that implement
             DOCSIS 2.0 Radio Frequency Interfaces."

   MODULE  -- docsIfMib

   -- unconditionally mandatory groups
   MANDATORY-GROUPS {
        docsIfBasicGroupV2
        }




Raftus & Cardona            Standards Track                   [Page 119]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   -- conditionally mandatory group
   GROUP docsIfCmGroupV2
        DESCRIPTION
            "This group is implemented only in cable modems, not in
             cable modem termination systems."

   -- conditionally mandatory group
   GROUP docsIfCmtsGroupV2
        DESCRIPTION
            "This group is implemented only in cable modem termination
             systems, not in cable modems."


   OBJECT  docsIfDownChannelFrequency
        WRITE-SYNTAX Integer32 (47000000..862000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems.
             A range of 54MHz to 860MHz is appropriate for a cable
             plant using a North American Sub-Split channel plan.
             The spectrum range has been expanded to accommodate
             a lower edge of 47MHz and an upper edge of 862MHz
             for some European channel plans.
             If DOCSIS is extended to cover other types of channel
             plans (and frequency allocations), this object will be
             modified accordingly."

   OBJECT  docsIfDownChannelWidth
        WRITE-SYNTAX Integer32 (6000000 | 8000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is important to implement this object as read-only.
             In cable modems, this object is always implemented as
             read-only.  The value of 6 MHz is appropriate for cable
             plants running under NTSC (National Television
             Standards Committee) standards.  The value of 8 MHz is
             appropriate for cable plants running under ETSI
             standards.  For other regional standards, this
             object will be modified accordingly."

   OBJECT  docsIfDownChannelModulation
        WRITE-SYNTAX INTEGER {
                               qam64 (3),
                               qam256 (4)
                             }
        MIN-ACCESS  read-only
        DESCRIPTION



Raftus & Cardona            Standards Track                   [Page 120]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfDownChannelInterleave
        WRITE-SYNTAX INTEGER {
                    taps8Increment16(3),
                    taps16Increment8(4),
                    taps32Increment4(5),
                    taps64Increment2(6),
                    taps128Increment1(7),
                    taps12increment17(8)
                     }
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfDownChannelPower
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-write in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelFrequency
        WRITE-SYNTAX Integer32 (5000000..65000000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems.
             A range of 5MHz to 42MHz is appropriate for a cable
             plant using a North American Sub-Split channel plan.
             The spectrum range has been expanded to accommodate
             an upper edge of 65MHz for some European channel plans.
             If DOCSIS is extended to cover other types of channel
             plans (and frequency allocations), this object will
             be modified accordingly."

   OBJECT  docsIfUpChannelWidth
        WRITE-SYNTAX Integer32 (200000..6400000)
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems,
             read-only in cable modems.  The above value is appropriate
             for cable plants running under NTSC (National Television
             Standards Committee) standards.  If DOCSIS is extended to
             work with other standards (e.g., European standards), this
             object will be modified accordingly."




Raftus & Cardona            Standards Track                   [Page 121]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   OBJECT  docsIfUpChannelModulationProfile
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelSlotSize
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfUpChannelRangingBackoffStart
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelRangingBackoffEnd
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelTxBackoffStart
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelTxBackoffEnd
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelScdmaActiveCodes
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems.
             The number of active codes when SCDMA is in use MUST range
             from 64 to 128 and MUST be a non-Prime value.
             Providing this range allows for the following features
             and capabilities:
                1) Power management in S-CDMA spreader-on frames
                   (with a 3 dB spread).



Raftus & Cardona            Standards Track                   [Page 122]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


                2) Avoidance of code 0.
                3) Flexible mini-slot sizes with and without the use of
                   code 0."

   OBJECT  docsIfUpChannelScdmaCodesPerSlot
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelScdmaFrameSize
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelScdmaHoppingSeed
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelCloneFrom
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelUpdate
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."

   OBJECT  docsIfUpChannelStatus
           MIN-ACCESS  read-only
           DESCRIPTION
               "Read-create in Cable Modem Termination Systems;
                read-only in Cable Modems.
                Entries associated to physical interfaces only support
                the read-only value 'active'."


   OBJECT  docsIfUpChannelPreEqEnable
        MIN-ACCESS  read-only
        DESCRIPTION
            "Read-create in cable modem termination systems;
             read-only in cable modems."



Raftus & Cardona            Standards Track                   [Page 123]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   OBJECT  docsIfQosProfPriority
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxUpBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfGuarUpBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxDownBandwidth
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfBaselinePrivacy
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfStatus
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."

   OBJECT  docsIfQosProfMaxTransmitBurst
        MIN-ACCESS  read-only
        DESCRIPTION
            "This object is always read-only in cable modems.
             It is compliant to implement this object as read-only
             in cable modem termination systems."



Raftus & Cardona            Standards Track                   [Page 124]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   OBJECT  docsIfCmRangingTimeout
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT docsIfCmStatusModulationType
       SYNTAX          INTEGER {
           unknown(0),
           tdma(1),
           atdma(2),
           scdma(3)
       }
        DESCRIPTION
            "CM does not use both modulation burst profiles of a
             'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
             not supported."

   OBJECT  docsIfCmtsServiceAdminStatus
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsSyncInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsUcdInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsInsertInterval
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsInvitedRangingAttempts
        MIN-ACCESS  read-only
        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT  docsIfCmtsQosProfilePermissions
        WRITE-SYNTAX     BITS {
            createByManagement(0),
            updateByManagement(1)
           }
        MIN-ACCESS  read-only



Raftus & Cardona            Standards Track                   [Page 125]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "It is compliant to implement this object as read-only."

   OBJECT docsIfCmtsModType
        WRITE-SYNTAX      INTEGER {
            qpsk(2),
            qam16(3),
            qam64(6)
        }
        DESCRIPTION
            "A management station MAY only set 64QAM, 16QAM, or QPSK
             modulation for Time or Code division Multiple Access,
             but others might be possible based on device
             configuration."

   OBJECT docsIfCmtsCmStatusModulationType
       SYNTAX          INTEGER {
           unknown(0),
           tdma(1),
           atdma(2),
           scdma(3)
       }
        DESCRIPTION
            "CM does not use both modulation burst profiles of a
             'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
             not supported."

        ::= { docsIfCompliances 2 }

   docsIfBasicGroup OBJECT-GROUP
        OBJECTS {
            docsIfDownChannelId,
            docsIfDownChannelFrequency,
            docsIfDownChannelWidth,
            docsIfDownChannelModulation,
            docsIfDownChannelInterleave,
            docsIfDownChannelPower,
            docsIfUpChannelId,
            docsIfUpChannelFrequency,
            docsIfUpChannelWidth,
            docsIfUpChannelModulationProfile,
            docsIfUpChannelSlotSize,
            docsIfUpChannelTxTimingOffset,
            docsIfUpChannelRangingBackoffStart,
            docsIfUpChannelRangingBackoffEnd,
            docsIfUpChannelTxBackoffStart,
            docsIfUpChannelTxBackoffEnd,
            docsIfQosProfPriority,



Raftus & Cardona            Standards Track                   [Page 126]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfQosProfMaxUpBandwidth,
            docsIfQosProfGuarUpBandwidth,
            docsIfQosProfMaxDownBandwidth,
            docsIfQosProfMaxTxBurst,
            docsIfQosProfBaselinePrivacy,
            docsIfQosProfStatus,
            docsIfSigQIncludesContention,
            docsIfSigQUnerroreds,
            docsIfSigQCorrecteds,
            docsIfSigQUncorrectables,
            docsIfSigQSignalNoise,
            docsIfSigQMicroreflections,
            docsIfSigQEqualizationData
        }
        STATUS      deprecated
        DESCRIPTION
            "Group of objects implemented in both cable modems and
             cable modem termination systems."
        ::= { docsIfGroups 1 }

   docsIfCmGroup OBJECT-GROUP
        OBJECTS {
            docsIfCmCmtsAddress,
            docsIfCmCapabilities,
            docsIfCmRangingTimeout,
            docsIfCmStatusValue,
            docsIfCmStatusCode,
            docsIfCmStatusTxPower,
            docsIfCmStatusResets,
            docsIfCmStatusLostSyncs,
            docsIfCmStatusInvalidMaps,
            docsIfCmStatusInvalidUcds,
            docsIfCmStatusInvalidRangingResponses,
            docsIfCmStatusInvalidRegistrationResponses,
            docsIfCmStatusT1Timeouts,
            docsIfCmStatusT2Timeouts,
            docsIfCmStatusT3Timeouts,
            docsIfCmStatusT4Timeouts,
            docsIfCmStatusRangingAborteds,
            docsIfCmServiceQosProfile,
            docsIfCmServiceTxSlotsImmed,
            docsIfCmServiceTxSlotsDed,
            docsIfCmServiceTxRetries,
            docsIfCmServiceTxExceededs,
            docsIfCmServiceRqRetries,
            docsIfCmServiceRqExceededs
        }
        STATUS      deprecated



Raftus & Cardona            Standards Track                   [Page 127]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


        DESCRIPTION
            "Group of objects implemented in cable modems."
        ::= { docsIfGroups 2 }

   docsIfCmtsGroup OBJECT-GROUP
        OBJECTS {
            docsIfCmtsCapabilities,
            docsIfCmtsSyncInterval,
            docsIfCmtsUcdInterval,
            docsIfCmtsMaxServiceIds,
            docsIfCmtsInvitedRangingAttempts,
            docsIfCmtsInsertInterval,
            docsIfCmtsStatusInvalidRangeReqs,
            docsIfCmtsStatusRangingAborteds,
            docsIfCmtsStatusInvalidRegReqs,
            docsIfCmtsStatusFailedRegReqs,
            docsIfCmtsStatusInvalidDataReqs,
            docsIfCmtsStatusT5Timeouts,
            docsIfCmtsCmStatusMacAddress,
            docsIfCmtsCmStatusIpAddress,
            docsIfCmtsCmStatusDownChannelIfIndex,
            docsIfCmtsCmStatusUpChannelIfIndex,
            docsIfCmtsCmStatusRxPower,
            docsIfCmtsCmStatusTimingOffset,
            docsIfCmtsCmStatusEqualizationData,
            docsIfCmtsCmStatusValue,
            docsIfCmtsCmStatusUnerroreds,
            docsIfCmtsCmStatusCorrecteds,
            docsIfCmtsCmStatusUncorrectables,
            docsIfCmtsCmStatusSignalNoise,
            docsIfCmtsCmStatusMicroreflections,
            docsIfCmtsServiceCmStatusIndex,
            docsIfCmtsServiceAdminStatus,
            docsIfCmtsServiceQosProfile,
            docsIfCmtsServiceCreateTime,
            docsIfCmtsServiceInOctets,
            docsIfCmtsServiceInPackets,
            docsIfCmtsModType,
            docsIfCmtsModControl,
            docsIfCmtsModPreambleLen,
            docsIfCmtsModDifferentialEncoding,
            docsIfCmtsModFECErrorCorrection,
            docsIfCmtsModFECCodewordLength,
            docsIfCmtsModScramblerSeed,
            docsIfCmtsModMaxBurstSize,
            docsIfCmtsModGuardTimeSize,
            docsIfCmtsModLastCodewordShortened,
            docsIfCmtsModScrambler,



Raftus & Cardona            Standards Track                   [Page 128]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmtsQosProfilePermissions,
            docsIfCmtsCmPtr
        }
        STATUS      deprecated
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination
             Systems."
        ::= { docsIfGroups 3 }

   -- obsolete group
   -- RFC 2670 already had a obsolete group, even though RFC2670
   -- was the first version of this MIB Module.

   docsIfObsoleteGroup OBJECT-GROUP
        OBJECTS {
            docsIfCmRangingRespTimeout,
            docsIfCmtsInsertionInterval
        }
        STATUS      obsolete
        DESCRIPTION
            "Group of objects obsoleted."
        ::= { docsIfGroups 4 }

   docsIfBasicGroupV2 OBJECT-GROUP
        OBJECTS {
            docsIfDownChannelId,
            docsIfDownChannelFrequency,
            docsIfDownChannelWidth,
            docsIfDownChannelModulation,
            docsIfDownChannelInterleave,
            docsIfDownChannelPower,
            docsIfDownChannelAnnex,
            docsIfUpChannelId,
            docsIfUpChannelFrequency,
            docsIfUpChannelWidth,
            docsIfUpChannelModulationProfile,
            docsIfUpChannelSlotSize,
            docsIfUpChannelTxTimingOffset,
            docsIfUpChannelRangingBackoffStart,
            docsIfUpChannelRangingBackoffEnd,
            docsIfUpChannelTxBackoffStart,
            docsIfUpChannelTxBackoffEnd,
            docsIfUpChannelScdmaActiveCodes,
            docsIfUpChannelScdmaCodesPerSlot,
            docsIfUpChannelScdmaFrameSize,
            docsIfUpChannelScdmaHoppingSeed,
            docsIfUpChannelType,
            docsIfUpChannelCloneFrom,



Raftus & Cardona            Standards Track                   [Page 129]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfUpChannelUpdate,
            docsIfUpChannelStatus,
            docsIfUpChannelPreEqEnable,
            docsIfQosProfPriority,
            docsIfQosProfMaxUpBandwidth,
            docsIfQosProfGuarUpBandwidth,
            docsIfQosProfMaxDownBandwidth,
            docsIfQosProfBaselinePrivacy,
            docsIfQosProfStatus,
            docsIfQosProfMaxTransmitBurst,
            docsIfSigQIncludesContention,
            docsIfSigQUnerroreds,
            docsIfSigQCorrecteds,
            docsIfSigQUncorrectables,
            docsIfSigQSignalNoise,
            docsIfSigQMicroreflections,
            docsIfSigQExtUnerroreds,
            docsIfSigQExtCorrecteds,
            docsIfSigQExtUncorrectables,
            docsIfDocsisBaseCapability
        }
        STATUS      current
        DESCRIPTION
            "Group of objects implemented in both cable modems and
             cable modem termination systems."
        ::= { docsIfGroups 5 }

   docsIfCmGroupV2 OBJECT-GROUP
        OBJECTS {
            docsIfCmCmtsAddress,
            docsIfCmCapabilities,
            docsIfCmRangingTimeout,
            docsIfCmStatusValue,
            docsIfCmStatusCode,
            docsIfCmStatusTxPower,
            docsIfCmStatusResets,
            docsIfCmStatusLostSyncs,
            docsIfCmStatusInvalidMaps,
            docsIfCmStatusInvalidUcds,
            docsIfCmStatusInvalidRangingResponses,
            docsIfCmStatusInvalidRegistrationResponses,
            docsIfCmStatusT1Timeouts,
            docsIfCmStatusT2Timeouts,
            docsIfCmStatusT3Timeouts,
            docsIfCmStatusT4Timeouts,
            docsIfCmStatusRangingAborteds,
            docsIfCmStatusDocsisOperMode,
            docsIfCmStatusModulationType,



Raftus & Cardona            Standards Track                   [Page 130]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmStatusEqualizationData,
            docsIfCmStatusUCCs,
            docsIfCmStatusUCCFails,
            docsIfCmServiceQosProfile,
            docsIfCmServiceTxSlotsImmed,
            docsIfCmServiceTxSlotsDed,
            docsIfCmServiceTxRetries,
            docsIfCmServiceTxExceededs,
            docsIfCmServiceRqRetries,
            docsIfCmServiceRqExceededs,
            docsIfCmServiceExtTxSlotsImmed,
            docsIfCmServiceExtTxSlotsDed,
            docsIfSigQEqualizationData
        }
        STATUS      current
        DESCRIPTION
            "Group of objects implemented in cable modems."
        ::= { docsIfGroups 6 }

   docsIfCmtsGroupV2 OBJECT-GROUP
        OBJECTS {
            docsIfCmtsCapabilities,
            docsIfCmtsSyncInterval,
            docsIfCmtsUcdInterval,
            docsIfCmtsMaxServiceIds,
            docsIfCmtsInvitedRangingAttempts,
            docsIfCmtsInsertInterval,
            docsIfCmtsMacStorageType,
            docsIfCmtsStatusInvalidRangeReqs,
            docsIfCmtsStatusRangingAborteds,
            docsIfCmtsStatusInvalidRegReqs,
            docsIfCmtsStatusFailedRegReqs,
            docsIfCmtsStatusInvalidDataReqs,
            docsIfCmtsStatusT5Timeouts,
            docsIfCmtsCmStatusMacAddress,
            docsIfCmtsCmStatusDownChannelIfIndex,
            docsIfCmtsCmStatusUpChannelIfIndex,
            docsIfCmtsCmStatusRxPower,
            docsIfCmtsCmStatusTimingOffset,
            docsIfCmtsCmStatusEqualizationData,
            docsIfCmtsCmStatusValue,
            docsIfCmtsCmStatusUnerroreds,
            docsIfCmtsCmStatusCorrecteds,
            docsIfCmtsCmStatusUncorrectables,
            docsIfCmtsCmStatusSignalNoise,
            docsIfCmtsCmStatusMicroreflections,
            docsIfCmtsCmStatusExtUnerroreds,
            docsIfCmtsCmStatusExtCorrecteds,



Raftus & Cardona            Standards Track                   [Page 131]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmtsCmStatusExtUncorrectables,
            docsIfCmtsCmStatusDocsisRegMode,
            docsIfCmtsCmStatusModulationType,
            docsIfCmtsCmStatusInetAddressType,
            docsIfCmtsCmStatusInetAddress,
            docsIfCmtsCmStatusValueLastUpdate,
            docsIfCmtsCmStatusHighResolutionTimingOffset,
            docsIfCmtsServiceAdminStatus,
            docsIfCmtsServiceQosProfile,
            docsIfCmtsServiceCreateTime,
            docsIfCmtsServiceInOctets,
            docsIfCmtsServiceInPackets,
            docsIfCmtsServiceNewCmStatusIndex,
            docsIfCmtsModType,
            docsIfCmtsModControl,
            docsIfCmtsModPreambleLen,
            docsIfCmtsModDifferentialEncoding,
            docsIfCmtsModFECErrorCorrection,
            docsIfCmtsModFECCodewordLength,
            docsIfCmtsModScramblerSeed,
            docsIfCmtsModMaxBurstSize,
            docsIfCmtsModGuardTimeSize,
            docsIfCmtsModLastCodewordShortened,
            docsIfCmtsModScrambler,
            docsIfCmtsModByteInterleaverDepth,
            docsIfCmtsModByteInterleaverBlockSize,
            docsIfCmtsModPreambleType,
            docsIfCmtsModTcmErrorCorrectionOn,
            docsIfCmtsModScdmaInterleaverStepSize,
            docsIfCmtsModScdmaSpreaderEnable,
            docsIfCmtsModScdmaSubframeCodes,
            docsIfCmtsModChannelType,
            docsIfCmtsModStorageType,
            docsIfCmtsQosProfilePermissions,
            docsIfCmtsCmPtr,
            docsIfCmtsChannelUtilizationInterval,
            docsIfCmtsChannelUtUtilization,
            docsIfCmtsDownChnlCtrId,
            docsIfCmtsDownChnlCtrTotalBytes,
            docsIfCmtsDownChnlCtrUsedBytes,
            docsIfCmtsDownChnlCtrExtTotalBytes,
            docsIfCmtsDownChnlCtrExtUsedBytes,
            docsIfCmtsUpChnlCtrId,
            docsIfCmtsUpChnlCtrTotalMslots,
            docsIfCmtsUpChnlCtrUcastGrantedMslots,
            docsIfCmtsUpChnlCtrTotalCntnMslots,
            docsIfCmtsUpChnlCtrUsedCntnMslots,
            docsIfCmtsUpChnlCtrExtTotalMslots,



Raftus & Cardona            Standards Track                   [Page 132]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


            docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
            docsIfCmtsUpChnlCtrExtTotalCntnMslots,
            docsIfCmtsUpChnlCtrExtUsedCntnMslots,
            docsIfCmtsUpChnlCtrCollCntnMslots,
            docsIfCmtsUpChnlCtrTotalCntnReqMslots,
            docsIfCmtsUpChnlCtrUsedCntnReqMslots,
            docsIfCmtsUpChnlCtrCollCntnReqMslots,
            docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
            docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
            docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
            docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
            docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
            docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
            docsIfCmtsUpChnlCtrExtCollCntnMslots,
            docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
            docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
            docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
            docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
            docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
            docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
            docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
            docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
            docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots,
            docsIfDownChannelStorageType,
            docsIfQosProfStorageType

        }
        STATUS      current
        DESCRIPTION
            "Group of objects implemented in Cable Modem Termination
             Systems."
        ::= { docsIfGroups 7 }

   END

















Raftus & Cardona            Standards Track                   [Page 133]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


5.  Revision History

5.1.  Scope

   The MIB module in this document has been developed to accommodate
   DOCSIS 2.0 devices and their system capabilities.  The MIB module is
   an update to RFC 2670 [RFC2670] with the additional incorporation of
   DOCSIS 2.0 [RFI2.0] and Euro-DOCSIS specification requirements
   [EN-300-429].

5.2.  Extension

   We have maintained the MIB objects as defined in RFC 2670 [RFC2670].
   In some cases new MIB objects have been created with identical
   functionality but greater capacity (i.e., 32 to 64 bits).  In these
   situations, both the original 32 bit objects and the new 64 bit
   objects must be implemented.

6.  Security Considerations

   This MIB module relates to a system that will provide metropolitan
   public internet access.  As such, improper manipulation of the MIB
   objects represented by this MIB module may result in denial of
   service to a large number of end-users.

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write or read-create.  Such objects
   may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   The CMTS is the controller of most of the parameters of the DOCSIS
   RFI Interface.  Therefore, write access to the CMTS MIB objects may
   compromise the end-user's services.

   In the CM case, the only read-write object of this MIB module is
   docsIfCmRangingTimeout, which if SET maliciously, may not constitute
   a critical factor of service degradation.

   The rest of the CM-required MIB objects in this MIB module are read-
   only, either by definition, or by compliance statements.

   The CMTS is the controller of most of the parameters of the DOCSIS
   RFI Interface.  Below are the CMTS MIB object's vulnerabilities:

   o  Objects in the docsIfBasicGroupv2, if SET maliciously, could
      result in a denial of service.  Particularly, SETs to objects in



Raftus & Cardona            Standards Track                   [Page 134]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


      docsIfDownstreamChannelTable, docsIfUpstreamChannelTable,
      docsIfCmtsModulationTable, and docsIfQosProfileTable (the last one
      in conjunction with the MIB object
      docsIfCmtsQosProfilePermissions) can alter negatively the physical
      and link layer parameters of upstream and downstream channels.

   o  The Object docsIfCmtsServiceAdminStatus of the docsIfCmtsGroupv2
      group, when SET maliciously by an attacker to 'disabled' or
      'destroyed', will interrupt the service of the corresponding cable
      modem.

   Some of the readable objects in this MIB module (i.e., objects with a
   MAX-ACCESS other than not-accessible) may be considered sensitive or
   vulnerable in some network environments.  It is thus important to
   control even GET and/or NOTIFY access to these objects and possibly
   to even encrypt the values of these objects when sending them over
   the network via SNMP.  Below are some sensitivity considerations:

   o  Read access to the MIB objects in tables docsIfCmStatusTable (CM),
      docsIfSignalQualityTable (CM/CMTS) and in CMTS tables
      docsIfCmtsCmStatusTable, docsIfCmtsChannelUtilizationTable,
      docsIfCmtsDownChannelCounterTable, and
      docsIfCmtsUpChannelCounterTable, could reveal information about
      the cable modems' distribution among the upstream and downstream
      channels and their performance, which could be used to gain access
      to a different tiered service offer.  The table
      docsIfCmtsCmStatusTable also contains the MAC and IP addresses of
      the cable modems, which can be used for theft of service.

   SNMP versions prior to SNMPv3 did not include adequate security.
   Even if the network itself is secure (for example by using IPSec),
   even then, there is no control as to who on the secure network is
   allowed to access and GET/SET (read/change/create/delete) the objects
   in this MIB module.

   It is RECOMMENDED that implementers consider the security features as
   provided by the SNMPv3 framework (see [RFC3410], section 8),
   including full support for the SNMPv3 cryptographic mechanisms (for
   authentication and privacy).

   Further, deployment of SNMP versions prior to SNMPv3 is NOT
   RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
   enable cryptographic security.  It is then a customer/operator
   responsibility to ensure that the SNMP entity giving access to an
   instance of this MIB module is properly configured to give access to
   the objects only to those principals (users) that have legitimate
   rights to indeed GET or SET (change/create/delete) them.




Raftus & Cardona            Standards Track                   [Page 135]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


7.  Management Interoperability of DOCSIS 1.0, 1.1, and 2.0

   The MIB module contained in this document updates RFC 2670 [RFC2670],
   primarily to handle the management requirements of the DOCSIS RF
   Interface of DOCSIS 2.0 [ITU-T_J.122].  RFC 2670 contains the DOCSIS
   RF Interface management requirements for DOCSIS 1.0 and DOCSIS 1.1.

   The management requirements of Class of Service (DOCSIS 1.0)
   pertaining to RFC 2670 are the same as this document update and are
   contained in the tables docsIfQosProfileTable, docsIfCmServiceTable,
   and docsIfCmtsServiceTable.

   DOCSIS 1.1 and DOCSIS 2.0 Quality of Service management requirements
   are defined in the DOCSIS management specifications [OSSI1.1] and
   [OSSI2.0], respectively.

8.  References

8.1.  Normative References

   [EN-300-429]  European Telecommunications Standard Institute, "ETSI
                 Standard EN 300 429, Version 1.2.1: Digital Video
                 Broadcasting (DVB), Framing structure, channel coding
                 and modulation for cable systems", April 1998.

   [IANA]        Internet Assigned Numbers Authority, "Internet Assigned
                 Numbers Authority", October 2005,
                 <http://www.iana.org/assignments/ianaiftype-mib/>.

   [ITU-T_J.112] Telecommunication Standardization Sector of
                 International Telecommunications Union, "Transmission
                 Systems for Interactive Cable Television Services,
                 Annex B.", March 2001, <http://www.itu.int/ITU-
                 T/studygroups/com09/>.

   [ITU-T_J.122] Telecommunication Standardization Sector of
                 International Telecommunications Union, "Second-
                 Generation Transmission Systems for Interactive Cable
                 Television Services.", December 2002,
                 <http://www.itu.int/ITU-T/studygroups/com09/>.

   [ITU-T_J.83]  Telecommunication Standardization Sector of
                 International Telecommunications Union, "ITU-T
                 Recommendation J.83(4/97), Digital multi-programme
                 systems for television sound and data services for
                 cable distribution.", April 1997,
                 <http://www.itu.int/ITU-T/studygroups/com09/>.




Raftus & Cardona            Standards Track                   [Page 136]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   [RFC2119]     Bradner, S., "Key words for use in RFCs to Indicate
                 Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC2578]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Structure of Management Information Version 2
                 (SMIv2)", STD 58, RFC 2578, April 1999.

   [RFC2579]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Textual Conventions for SMIv2", STD 58, RFC 2579,
                 April 1999.

   [RFC2580]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                 "Conformance Statements for SMIv2", STD 58, RFC 2580,
                 April 1999.

   [RFC2863]     McCloghrie, K. and F. Kastenholz, "The Interfaces Group
                 MIB", RFC 2863, June 2000.

   [RFC4001]     Daniele, M., Haberman, B., Routhier, S., and J.
                 Schoenwaelder, "Textual Conventions for Internet
                 Network Addresses", RFC 4001, February 2005.

   [RFI1.1]      CableLabs, "Data-Over-Cable Service Interface
                 Specifications: Radio Frequency Interface Specification
                 SP-RFIv1.1-C01-050907", September 2005,
                 <http://www.cablemodem.com/specifications/>.

   [RFI2.0]      CableLabs, "Data-Over-Cable Service Interface
                 Specifications: Radio Frequency Interface Specification
                 SP-RFIv2.0-I09-050812", August 2005,
                 <http://www.cablemodem.com/specifications/>.

8.2.  Informative References

   [BPI]         SCTE Data Standards Subcommittee, "Data-Over-Cable
                 Service Interface Specifications: DOCSIS 1.0 Baseline
                 Privacy Interface Specification SCTE 22-2 2002", 2002,
                 <http://www.scte.org/standards/>.

   [BPIPLUS]     CableLabs, "Data-Over-Cable Service Interface
                 Specifications: Baseline Privacy Plus Interface
                 Specification SP-BPI+-I12-050812", August 2005,
                 <http://www.cablemodem.com/specifications/>.

   [OSSI1.1]     CableLabs, "Data-Over-Cable Service Interface
                 Specifications: Operations Support System Interface
                 Specification SP-OSSIv1.1-C01-050907", September 2005,
                 <http://www.cablemodem.com/specifications/>.



Raftus & Cardona            Standards Track                   [Page 137]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


   [OSSI2.0]     CableLabs, "Data-Over-Cable Service Interface
                 Specifications: Operations Support System Interface
                 Specification SP-OSSIv2.0-I09-050812", September 2005,
                 <http://www.cablemodem.com/specifications/>.

   [Proakis00]   McGraw-Hill, "Digital Communications, 4th Edition",
                 2000.

   [RFC2670]     St. Johns, M., "Radio Frequency (RF) Interface
                 Management Information Base for MCNS/DOCSIS compliant
                 RF interfaces", RFC 2670, August 1999.

   [RFC3410]     Case, J., Mundy, R., Partain, D., and B. Stewart,
                 "Introduction and Applicability Statements for
                 Internet-Standard Management Framework", RFC 3410,
                 December 2002.

   [RFI1.0]      SCTE Data Standards Subcommittee, "Data-Over-Cable
                 Service Interface Specifications: DOCSIS 1.0 Radio
                 Frequency Interface Specification SCTE 22-1 2002",
                 2002, <http://www.scte.org/standards/>.

Authors' Addresses

   David Raftus
   ATI Technologies
   340 Terry Fox Drive, Suite 202
   Ottawa, Ontario
   Canada

   Phone: +1 613 592 1052 ext.222
   EMail: david.raftus@ati.com


   Eduardo Cardona
   Cable Television Laboratories, Inc.
   858 Coal Creek Circle
   Louisville, CO  80020
   USA

   Phone: +1 303 661 3375
   EMail: e.cardona@cablelabs.com









Raftus & Cardona            Standards Track                   [Page 138]
^L
RFC 4546          DOCSIS 2.0 Radio Frequency (RFI) MIB         June 2006


Full Copyright Statement

   Copyright (C) The Internet Society (2006).

   This document is subject to the rights, licenses and restrictions
   contained in BCP 78, and except as set forth therein, the authors
   retain all their rights.

   This document and the information contained herein are provided on an
   "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
   OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
   ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
   INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
   INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
   WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   Intellectual Property Rights or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available; nor does it represent that it has
   made any independent effort to identify any such rights.  Information
   on the procedures with respect to rights in RFC documents can be
   found in BCP 78 and BCP 79.

   Copies of IPR disclosures made to the IETF Secretariat and any
   assurances of licenses to be made available, or the result of an
   attempt made to obtain a general license or permission for the use of
   such proprietary rights by implementers or users of this
   specification can be obtained from the IETF on-line IPR repository at
   http://www.ietf.org/ipr.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights that may cover technology that may be required to implement
   this standard.  Please address the information to the IETF at
   ietf-ipr@ietf.org.

Acknowledgement

   Funding for the RFC Editor function is provided by the IETF
   Administrative Support Activity (IASA).







Raftus & Cardona            Standards Track                   [Page 139]
^L