1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
|
Network Working Group C. Jennings, Ed.
Request for Comments: 5626 Cisco Systems
Updates: 3261, 3327 R. Mahy, Ed.
Category: Standards Track Unaffiliated
F. Audet, Ed.
Skype Labs
October 2009
Managing Client-Initiated Connections
in the Session Initiation Protocol (SIP)
Abstract
The Session Initiation Protocol (SIP) allows proxy servers to
initiate TCP connections or to send asynchronous UDP datagrams to
User Agents in order to deliver requests. However, in a large number
of real deployments, many practical considerations, such as the
existence of firewalls and Network Address Translators (NATs) or the
use of TLS with server-provided certificates, prevent servers from
connecting to User Agents in this way. This specification defines
behaviors for User Agents, registrars, and proxy servers that allow
requests to be delivered on existing connections established by the
User Agent. It also defines keep-alive behaviors needed to keep NAT
bindings open and specifies the usage of multiple connections from
the User Agent to its registrar.
Status of This Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (c) 2009 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
Jennings, et al. Standards Track [Page 1]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
the Trust Legal Provisions and are provided without warranty as
described in the BSD License.
This document may contain material from IETF Documents or IETF
Contributions published or made publicly available before November
10, 2008. The person(s) controlling the copyright in some of this
material may not have granted the IETF Trust the right to allow
modifications of such material outside the IETF Standards Process.
Without obtaining an adequate license from the person(s) controlling
the copyright in such materials, this document may not be modified
outside the IETF Standards Process, and derivative works of it may
not be created outside the IETF Standards Process, except to format
it for publication as an RFC or to translate it into languages other
than English.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Conventions and Terminology . . . . . . . . . . . . . . . . . 5
2.1. Definitions . . . . . . . . . . . . . . . . . . . . . . . 5
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1. Summary of Mechanism . . . . . . . . . . . . . . . . . . . 6
3.2. Single Registrar and UA . . . . . . . . . . . . . . . . . 7
3.3. Multiple Connections from a User Agent . . . . . . . . . . 8
3.4. Edge Proxies . . . . . . . . . . . . . . . . . . . . . . . 10
3.5. Keep-Alive Technique . . . . . . . . . . . . . . . . . . . 11
3.5.1. CRLF Keep-Alive Technique . . . . . . . . . . . . . . 12
3.5.2. STUN Keep-Alive Technique . . . . . . . . . . . . . . 12
4. User Agent Procedures . . . . . . . . . . . . . . . . . . . . 13
4.1. Instance ID Creation . . . . . . . . . . . . . . . . . . . 13
4.2. Registrations . . . . . . . . . . . . . . . . . . . . . . 14
4.2.1. Initial Registrations . . . . . . . . . . . . . . . . 14
4.2.2. Subsequent REGISTER Requests . . . . . . . . . . . . . 16
4.2.3. Third-Party Registrations . . . . . . . . . . . . . . 17
4.3. Sending Non-REGISTER Requests . . . . . . . . . . . . . . 17
4.4. Keep-Alives and Detecting Flow Failure . . . . . . . . . . 18
4.4.1. Keep-Alive with CRLF . . . . . . . . . . . . . . . . . 19
4.4.2. Keep-Alive with STUN . . . . . . . . . . . . . . . . . 21
4.5. Flow Recovery . . . . . . . . . . . . . . . . . . . . . . 21
5. Edge Proxy Procedures . . . . . . . . . . . . . . . . . . . . 22
5.1. Processing Register Requests . . . . . . . . . . . . . . . 22
5.2. Generating Flow Tokens . . . . . . . . . . . . . . . . . . 23
5.3. Forwarding Non-REGISTER Requests . . . . . . . . . . . . . 23
5.3.1. Processing Incoming Requests . . . . . . . . . . . . . 24
5.3.2. Processing Outgoing Requests . . . . . . . . . . . . . 24
5.4. Edge Proxy Keep-Alive Handling . . . . . . . . . . . . . . 25
6. Registrar Procedures . . . . . . . . . . . . . . . . . . . . . 25
7. Authoritative Proxy Procedures: Forwarding Requests . . . . . 27
Jennings, et al. Standards Track [Page 2]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
8. STUN Keep-Alive Processing . . . . . . . . . . . . . . . . . . 28
8.1. Use with SigComp . . . . . . . . . . . . . . . . . . . . . 29
9. Example Message Flow . . . . . . . . . . . . . . . . . . . . . 30
9.1. Subscription to Configuration Package . . . . . . . . . . 30
9.2. Registration . . . . . . . . . . . . . . . . . . . . . . . 32
9.3. Incoming Call and Proxy Crash . . . . . . . . . . . . . . 34
9.4. Re-Registration . . . . . . . . . . . . . . . . . . . . . 37
9.5. Outgoing Call . . . . . . . . . . . . . . . . . . . . . . 38
10. Grammar . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 40
11.1. Flow-Timer Header Field . . . . . . . . . . . . . . . . . 40
11.2. "reg-id" Contact Header Field Parameter . . . . . . . . . 40
11.3. SIP/SIPS URI Parameters . . . . . . . . . . . . . . . . . 41
11.4. SIP Option Tag . . . . . . . . . . . . . . . . . . . . . . 41
11.5. 430 (Flow Failed) Response Code . . . . . . . . . . . . . 41
11.6. 439 (First Hop Lacks Outbound Support) Response Code . . . 42
11.7. Media Feature Tag . . . . . . . . . . . . . . . . . . . . 42
12. Security Considerations . . . . . . . . . . . . . . . . . . . 43
13. Operational Notes on Transports . . . . . . . . . . . . . . . 44
14. Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 44
15. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 45
16. References . . . . . . . . . . . . . . . . . . . . . . . . . . 45
16.1. Normative References . . . . . . . . . . . . . . . . . . . 45
16.2. Informative References . . . . . . . . . . . . . . . . . . 47
Appendix A. Default Flow Registration Backoff Times . . . . . . . 49
Appendix B. ABNF . . . . . . . . . . . . . . . . . . . . . . . . 49
Jennings, et al. Standards Track [Page 3]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
1. Introduction
There are many environments for SIP [RFC3261] deployments in which
the User Agent (UA) can form a connection to a registrar or proxy but
in which connections in the reverse direction to the UA are not
possible. This can happen for several reasons, but the most likely
is a NAT or a firewall in between the SIP UA and the proxy. Many
such devices will only allow outgoing connections. This
specification allows a SIP User Agent behind such a firewall or NAT
to receive inbound traffic associated with registrations or dialogs
that it initiates.
Most IP phones and personal computers get their network
configurations dynamically via a protocol such as the Dynamic Host
Configuration Protocol (DHCP) [RFC2131]. These systems typically do
not have a useful name in the Domain Name System (DNS) [RFC1035], and
they almost never have a long-term, stable DNS name that is
appropriate for use in the subjectAltName of a certificate, as
required by [RFC3261]. However, these systems can still act as a
Transport Layer Security (TLS) [RFC5246] client and form outbound
connections to a proxy or registrar that authenticates with a server
certificate. The server can authenticate the UA using a shared
secret in a digest challenge (as defined in Section 22 of RFC 3261)
over that TLS connection. This specification allows a SIP User Agent
who has to initiate the TLS connection to receive inbound traffic
associated with registrations or dialogs that it initiates.
The key idea of this specification is that when a UA sends a REGISTER
request or a dialog-forming request, the proxy can later use this
same network "flow" -- whether this is a bidirectional stream of UDP
datagrams, a TCP connection, or an analogous concept in another
transport protocol -- to forward any incoming requests that need to
go to this UA in the context of the registration or dialog.
For a UA to receive incoming requests, the UA has to connect to a
server. Since the server can't connect to the UA, the UA has to make
sure that a flow is always active. This requires the UA to detect
when a flow fails. Since such detection takes time and leaves a
window of opportunity for missed incoming requests, this mechanism
allows the UA to register over multiple flows at the same time. This
specification also defines two keep-alive schemes. The keep-alive
mechanism is used to keep NAT bindings fresh, and to allow the UA to
detect when a flow has failed.
Jennings, et al. Standards Track [Page 4]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
2. Conventions and Terminology
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
2.1. Definitions
Authoritative Proxy: A proxy that handles non-REGISTER requests for
a specific Address-of-Record (AOR), performs the logical Location
Server lookup described in [RFC3261], and forwards those requests
to specific Contact URIs. (In [RFC3261], the role that is
authoritative for REGISTER requests for a specific AOR is a
Registration Server.)
Edge Proxy: An edge proxy is any proxy that is located topologically
between the registering User Agent and the Authoritative Proxy.
The "first" edge proxy refers to the first edge proxy encountered
when a UA sends a request.
Flow: A Flow is a transport-layer association between two hosts that
is represented by the network address and port number of both ends
and by the transport protocol. For TCP, a flow is equivalent to a
TCP connection. For UDP a flow is a bidirectional stream of
datagrams between a single pair of IP addresses and ports of both
peers. With TCP, a flow often has a one-to-one correspondence
with a single file descriptor in the operating system.
Flow Token: An identifier that uniquely identifies a flow which can
be included in a SIP URI (Uniform Resource Identifier [RFC3986]).
reg-id: This refers to the value of a new header field parameter
value for the Contact header field. When a UA registers multiple
times, each for a different flow, each concurrent registration
gets a unique reg-id value.
instance-id: This specification uses the word instance-id to refer
to the value of the "sip.instance" media feature tag which appears
as a "+sip.instance" Contact header field parameter. This is a
Uniform Resource Name (URN) that uniquely identifies this specific
UA instance.
"ob" Parameter: The "ob" parameter is a SIP URI parameter that has a
different meaning depending on context. In a Path header field
value, it is used by the first edge proxy to indicate that a flow
token was added to the URI. In a Contact or Route header field
value, it indicates that the UA would like other requests in the
same dialog to be routed over the same flow.
Jennings, et al. Standards Track [Page 5]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
outbound-proxy-set: A set of SIP URIs (Uniform Resource Identifiers)
that represents each of the outbound proxies (often edge proxies)
with which the UA will attempt to maintain a direct flow. The
first URI in the set is often referred to as the primary outbound
proxy and the second as the secondary outbound proxy. There is no
difference between any of the URIs in this set, nor does the
primary/secondary terminology imply that one is preferred over the
other.
3. Overview
The mechanisms defined in this document are useful in several
scenarios discussed below, including the simple co-located registrar
and proxy, a User Agent desiring multiple connections to a resource
(for redundancy, for example), and a system that uses edge proxies.
This entire section is non-normative.
3.1. Summary of Mechanism
Each UA has a unique instance-id that stays the same for this UA even
if the UA reboots or is power cycled. Each UA can register multiple
times over different flows for the same SIP Address of Record (AOR)
to achieve high reliability. Each registration includes the
instance-id for the UA and a reg-id label that is different for each
flow. The registrar can use the instance-id to recognize that two
different registrations both correspond to the same UA. The
registrar can use the reg-id label to recognize whether a UA is
creating a new flow or refreshing or replacing an old one, possibly
after a reboot or a network failure.
When a proxy goes to route a message to a UA for which it has a
binding, it can use any one of the flows on which a successful
registration has been completed. A failure to deliver a request on a
particular flow can be tried again on an alternate flow. Proxies can
determine which flows go to the same UA by comparing the instance-id.
Proxies can tell that a flow replaces a previously abandoned flow by
looking at the reg-id.
When sending a dialog-forming request, a UA can also ask its first
edge proxy to route subsequent requests in that dialog over the same
flow. This is necessary whether the UA has registered or not.
UAs use a simple periodic message as a keep-alive mechanism to keep
their flow to the proxy or registrar alive. For connection-oriented
transports such as TCP this is based on carriage-return and line-feed
Jennings, et al. Standards Track [Page 6]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
sequences (CRLF), while for transports that are not connection
oriented, this is accomplished by using a SIP-specific usage profile
of STUN (Session Traversal Utilities for NAT) [RFC5389].
3.2. Single Registrar and UA
In the topology shown below, a single server is acting as both a
registrar and proxy.
+-----------+
| Registrar |
| Proxy |
+-----+-----+
|
|
+----+--+
| User |
| Agent |
+-------+
User Agents that form only a single flow continue to register
normally but include the instance-id as described in Section 4.1.
The UA also includes a "reg-id" Contact header field parameter that
is used to allow the registrar to detect and avoid keeping invalid
contacts when a UA reboots or reconnects after its old connection has
failed for some reason.
For clarity, here is an example. Bob's UA creates a new TCP flow to
the registrar and sends the following REGISTER request.
REGISTER sip:example.com SIP/2.0
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bK-bad0ce-11-1036
Max-Forwards: 70
From: Bob <sip:bob@example.com>;tag=d879h76
To: Bob <sip:bob@example.com>
Call-ID: 8921348ju72je840.204
CSeq: 1 REGISTER
Supported: path, outbound
Contact: <sip:line1@192.0.2.2;transport=tcp>; reg-id=1;
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-000A95A0E128>"
Content-Length: 0
The registrar challenges this registration to authenticate Bob. When
the registrar adds an entry for this contact under the AOR for Bob,
the registrar also keeps track of the connection over which it
received this registration.
Jennings, et al. Standards Track [Page 7]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The registrar saves the instance-id
("urn:uuid:00000000-0000-1000-8000-000A95A0E128") and reg-id ("1")
along with the rest of the Contact header field. If the instance-id
and reg-id are the same as a previous registration for the same AOR,
the registrar replaces the old Contact URI and flow information.
This allows a UA that has rebooted to replace its previous
registration for each flow with minimal impact on overall system
load.
When Alice sends a request to Bob, his authoritative proxy selects
the target set. The proxy forwards the request to elements in the
target set based on the proxy's policy. The proxy looks at the
target set and uses the instance-id to understand if two targets both
end up routing to the same UA. When the proxy goes to forward a
request to a given target, it looks and finds the flows over which it
received the registration. The proxy then forwards the request over
an existing flow, instead of resolving the Contact URI using the
procedures in [RFC3263] and trying to form a new flow to that
contact.
As described in the next section, if the proxy has multiple flows
that all go to this UA, the proxy can choose any one of the
registration bindings for this AOR that has the same instance-id as
the selected UA.
3.3. Multiple Connections from a User Agent
There are various ways to deploy SIP to build a reliable and scalable
system. This section discusses one such design that is possible with
the mechanisms in this specification. Other designs are also
possible.
In the example system below, the logical outbound proxy/registrar for
the domain is running on two hosts that share the appropriate state
and can both provide registrar and outbound proxy functionality for
the domain. The UA will form connections to two of the physical
hosts that can perform the authoritative proxy/registrar function for
the domain. Reliability is achieved by having the UA form two TCP
connections to the domain.
Jennings, et al. Standards Track [Page 8]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
+-------------------+
| Domain |
| Logical Proxy/Reg |
| |
|+-----+ +-----+|
||Host1| |Host2||
|+-----+ +-----+|
+---\------------/--+
\ /
\ /
\ /
\ /
+------+
| User |
| Agent|
+------+
The UA is configured with multiple outbound proxy registration URIs.
These URIs are configured into the UA through whatever the normal
mechanism is to configure the proxy address and AOR in the UA. If
the AOR is alice@example.com, the outbound-proxy-set might look
something like "sip:primary.example.com" and "sip:
secondary.example.com". Note that each URI in the outbound-proxy-set
could resolve to several different physical hosts. The
administrative domain that created these URIs should ensure that the
two URIs resolve to separate hosts. These URIs are handled according
to normal SIP processing rules, so mechanisms like DNS SRV [RFC2782]
can be used to do load-balancing across a proxy farm. The approach
in this document does not prevent future extensions, such as the SIP
UA configuration framework [CONFIG-FMWK], from adding other ways for
a User Agent to discover its outbound-proxy-set.
The domain also needs to ensure that a request for the UA sent to
Host1 or Host2 is then sent across the appropriate flow to the UA.
The domain might choose to use the Path header approach (as described
in the next section) to store this internal routing information on
Host1 or Host2.
When a single server fails, all the UAs that have a flow through it
will detect a flow failure and try to reconnect. This can cause
large loads on the server. When large numbers of hosts reconnect
nearly simultaneously, this is referred to as the avalanche restart
problem, and is further discussed in Section 4.5. The multiple flows
to many servers help reduce the load caused by the avalanche restart.
If a UA has multiple flows, and one of the servers fails, the UA
delays a recommended amount of time before trying to form a new
Jennings, et al. Standards Track [Page 9]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
connection to replace the flow to the server that failed. By
spreading out the time used for all the UAs to reconnect to a server,
the load on the server farm is reduced.
Scalability is achieved by using DNS SRV [RFC2782] to load-balance
the primary connection across a set of machines that can service the
primary connection, and also using DNS SRV to load-balance across a
separate set of machines that can service the secondary connection.
The deployment here requires that DNS is configured with one entry
that resolves to all the primary hosts and another entry that
resolves to all the secondary hosts. While this introduces
additional DNS configuration, the approach works and requires no
additional SIP extensions to [RFC3263].
Another motivation for maintaining multiple flows between the UA and
its registrar is related to multihomed UAs. Such UAs can benefit
from multiple connections from different interfaces to protect
against the failure of an individual access link.
3.4. Edge Proxies
Some SIP deployments use edge proxies such that the UA sends the
REGISTER to an edge proxy that then forwards the REGISTER to the
registrar. There could be a NAT or firewall between the UA and the
edge proxy.
+---------+
|Registrar|
|Proxy |
+---------+
/ \
/ \
/ \
+-----+ +-----+
|Edge1| |Edge2|
+-----+ +-----+
\ /
\ /
----------------------------NAT/FW
\ /
\ /
+------+
|User |
|Agent |
+------+
Jennings, et al. Standards Track [Page 10]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The edge proxy includes a Path header [RFC3327] so that when the
proxy/registrar later forwards a request to this UA, the request is
routed through the edge proxy.
These systems can use effectively the same mechanism as described in
the previous sections but need to use the Path header. When the edge
proxy receives a registration, it needs to create an identifier value
that is unique to this flow (and not a subsequent flow with the same
addresses) and put this identifier in the Path header URI. This
identifier has two purposes. First, it allows the edge proxy to map
future requests back to the correct flow. Second, because the
identifier will only be returned if the user authenticates with the
registrar successfully, it allows the edge proxy to indirectly check
the user's authentication information via the registrar. The
identifier is placed in the user portion of a loose route in the Path
header. If the registration succeeds, the edge proxy needs to map
future requests (that are routed to the identifier value from the
Path header) to the associated flow.
The term edge proxy is often used to refer to deployments where the
edge proxy is in the same administrative domain as the registrar.
However, in this specification we use the term to refer to any proxy
between the UA and the registrar. For example, the edge proxy may be
inside an enterprise that requires its use, and the registrar could
be from a service provider with no relationship to the enterprise.
Regardless of whether they are in the same administrative domain,
this specification requires that registrars and edge proxies support
the Path header mechanism in [RFC3327].
3.5. Keep-Alive Technique
This document describes two keep-alive mechanisms: a CRLF keep-alive
and a STUN keep-alive. Each of these mechanisms uses a client-to-
server "ping" keep-alive and a corresponding server-to-client "pong"
message. This ping-pong sequence allows the client, and optionally
the server, to tell if its flow is still active and useful for SIP
traffic. The server responds to pings by sending pongs. If the
client does not receive a pong in response to its ping (allowing for
retransmission for STUN as described in Section 4.4.2), it declares
the flow dead and opens a new flow in its place.
This document also suggests timer values for these client keep-alive
mechanisms. These timer values were chosen to keep most NAT and
firewall bindings open, to detect unresponsive servers within 2
minutes, and to mitigate against the avalanche restart problem.
However, the client may choose different timer values to suit its
needs, for example to optimize battery life. In some environments,
Jennings, et al. Standards Track [Page 11]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
the server can also keep track of the time since a ping was received
over a flow to guess the likelihood that the flow is still useful for
delivering SIP messages.
When the UA detects that a flow has failed or that the flow
definition has changed, the UA needs to re-register and will use the
back-off mechanism described in Section 4.5 to provide congestion
relief when a large number of agents simultaneously reboot.
A keep-alive mechanism needs to keep NAT bindings refreshed; for
connections, it also needs to detect failure of a connection; and for
connectionless transports, it needs to detect flow failures including
changes to the NAT public mapping. For connection-oriented
transports such as TCP [RFC0793] and SCTP [RFC4960], this
specification describes a keep-alive approach based on sending CRLFs.
For connectionless transport, such as UDP [RFC0768], this
specification describes using STUN [RFC5389] over the same flow as
the SIP traffic to perform the keep-alive.
UAs and Proxies are also free to use native transport keep-alives;
however, the application may not be able to set these timers on a
per-connection basis, and the server certainly cannot make any
assumption about what values are used. Use of native transport
keep-alives is outside the scope of this document.
3.5.1. CRLF Keep-Alive Technique
This approach can only be used with connection-oriented transports
such as TCP or SCTP. The client periodically sends a double-CRLF
(the "ping") then waits to receive a single CRLF (the "pong"). If
the client does not receive a "pong" within an appropriate amount of
time, it considers the flow failed.
Note: Sending a CRLF over a connection-oriented transport is
backwards compatible (because of requirements in Section 7.5 of
[RFC3261]), but only implementations which support this
specification will respond to a "ping" with a "pong".
3.5.2. STUN Keep-Alive Technique
This approach can only be used for connection-less transports, such
as UDP.
For connection-less transports, a flow definition could change
because a NAT device in the network path reboots and the resulting
public IP address or port mapping for the UA changes. To detect
this, STUN requests are sent over the same flow that is being used
Jennings, et al. Standards Track [Page 12]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
for the SIP traffic. The proxy or registrar acts as a limited
Session Traversal Utilities for NAT (STUN) [RFC5389] server on the
SIP signaling port.
Note: The STUN mechanism is very robust and allows the detection
of a changed IP address and port. Many other options were
considered, but the SIP Working Group selected the STUN-based
approach. Approaches using SIP requests were abandoned because
many believed that good performance and full backwards
compatibility using this method were mutually exclusive.
4. User Agent Procedures
4.1. Instance ID Creation
Each UA MUST have an Instance Identifier Uniform Resource Name (URN)
[RFC2141] that uniquely identifies the device. Usage of a URN
provides a persistent and unique name for the UA instance. It also
provides an easy way to guarantee uniqueness within the AOR. This
URN MUST be persistent across power cycles of the device. The
instance ID MUST NOT change as the device moves from one network to
another.
A UA SHOULD create a Universally Unique Identifier (UUID) URN
[RFC4122] as its instance-id. The UUID URN allows for non-
centralized computation of a URN based on time, unique names (such as
a MAC address), or a random number generator.
Note: A device like a "soft phone", when first installed, can
generate a UUID [RFC4122] and then save this in persistent storage
for all future use. For a device such as a "hard phone", which
will only ever have a single SIP UA present, the UUID can include
the MAC address and be generated at any time because it is
guaranteed that no other UUID is being generated at the same time
on that physical device. This means the value of the time
component of the UUID can be arbitrarily selected to be any time
less than the time when the device was manufactured. A time of 0
(as shown in the example in Section 3.2) is perfectly legal as
long as the device knows no other UUIDs were generated at this
time on this device.
If a URN scheme other than UUID is used, the UA MUST only use URNs
for which an RFC (from the IETF stream) defines how the specific URN
needs to be constructed and used in the "+sip.instance" Contact
header field parameter for outbound behavior.
Jennings, et al. Standards Track [Page 13]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
To convey its instance-id in both requests and responses, the UA
includes a "sip.instance" media feature tag as a UA characteristic
[RFC3840]. This media feature tag is encoded in the Contact header
field as the "+sip.instance" Contact header field parameter. One
case where a UA could prefer to omit the "sip.instance" media feature
tag is when it is making an anonymous request or some other privacy
concern requires that the UA not reveal its identity.
Note: [RFC3840] defines equality rules for callee capabilities
parameters, and according to that specification, the
"sip.instance" media feature tag will be compared by case-
sensitive string comparison. This means that the URN will be
encapsulated by angle brackets ("<" and ">") when it is placed
within the quoted string value of the "+sip.instance" Contact
header field parameter. The case-sensitive matching rules apply
only to the generic usages defined in the callee capabilities
[RFC3840] and the caller preferences [RFC3841] specifications.
When the instance ID is used in this specification, it is
"extracted" from the value in the "sip.instance" media feature
tag. Thus, equality comparisons are performed using the rules for
URN equality that are specific to the scheme in the URN. If the
element performing the comparisons does not understand the URN
scheme, it performs the comparisons using the lexical equality
rules defined in [RFC2141]. Lexical equality could result in two
URNs being considered unequal when they are actually equal. In
this specific usage of URNs, the only element that provides the
URN is the SIP UA instance identified by that URN. As a result,
the UA instance has to provide lexically equivalent URNs in each
registration it generates. This is likely to be normal behavior
in any case; clients are not likely to modify the value of the
instance ID so that it remains functionally equivalent to (yet
lexicographically different from) previous registrations.
4.2. Registrations
4.2.1. Initial Registrations
At configuration time, UAs obtain one or more SIP URIs representing
the default outbound-proxy-set. This specification assumes the set
is determined via any of a number of configuration mechanisms, and
future specifications can define additional mechanisms such as using
DNS to discover this set. How the UA is configured is outside the
scope of this specification. However, a UA MUST support sets with at
least two outbound proxy URIs and SHOULD support sets with up to four
URIs.
Jennings, et al. Standards Track [Page 14]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
For each outbound proxy URI in the set, the User Agent Client (UAC)
SHOULD send a REGISTER request using this URI as the default outbound
proxy. (Alternatively, the UA could limit the number of flows formed
to conserve battery power, for example). If the set has more than
one URI, the UAC MUST send a REGISTER request to at least two of the
default outbound proxies from the set. UAs that support this
specification MUST include the outbound option tag in a Supported
header field in a REGISTER request. Each of these REGISTER requests
will use a unique Call-ID. Forming the route set for the request is
outside the scope of this document, but typically results in sending
the REGISTER such that the topmost Route header field contains a
loose route to the outbound proxy URI.
REGISTER requests, other than those described in Section 4.2.3, MUST
include an instance-id media feature tag as specified in Section 4.1.
A UAC conforming to this specification MUST include in the Contact
header field, a "reg-id" parameter that is distinct from other
"reg-id" parameters used in other registrations that use the same
"+sip.instance" Contact header field parameter and AOR. Each one of
these registrations will form a new flow from the UA to the proxy.
The sequence of reg-id values does not have to be sequential but MUST
be exactly the same sequence of reg-id values each time the UA
instance power cycles or reboots, so that the reg-id values will
collide with the previously used reg-id values. This is so the
registrar can replace the older registrations.
Note: The UAC can situationally decide whether to request outbound
behavior by including or omitting the "reg-id" Contact header
field parameter. For example, imagine the outbound-proxy-set
contains two proxies in different domains, EP1 and EP2. If an
outbound-style registration succeeded for a flow through EP1, the
UA might decide to include 'outbound' in its Require header field
when registering with EP2, in order to ensure consistency.
Similarly, if the registration through EP1 did not support
outbound, the UA might not register with EP2 at all.
The UAC MUST support the Path header [RFC3327] mechanism, and
indicate its support by including the 'path' option-tag in a
Supported header field value in its REGISTER requests. Other than
optionally examining the Path vector in the response, this is all
that is required of the UAC to support Path.
The UAC examines successful registration responses for the presence
of an outbound option-tag in a Require header field value. Presence
of this option-tag indicates that the registrar is compliant with
this specification, and that any edge proxies which needed to
participate are also compliant. If the registrar did not support
Jennings, et al. Standards Track [Page 15]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
outbound, the UA has potentially registered an un-routable contact.
It is the responsibility of the UA to remove any inappropriate
Contacts.
If outbound registration succeeded, as indicated by the presence of
the outbound option-tag in the Require header field of a successful
registration response, the UA begins sending keep-alives as described
in Section 4.4.
Note: The UA needs to honor 503 (Service Unavailable) responses to
registrations as described in [RFC3261] and [RFC3263]. In
particular, implementors should note that when receiving a 503
(Service Unavailable) response with a Retry-After header field,
the UA is expected to wait the indicated amount of time and retry
the registration. A Retry-After header field value of 0 is valid
and indicates the UA is expected to retry the REGISTER request
immediately. Implementations need to ensure that when retrying
the REGISTER request, they revisit the DNS resolution results such
that the UA can select an alternate host from the one chosen the
previous time the URI was resolved.
If the registering UA receives a 439 (First Hop Lacks Outbound
Support) response to a REGISTER request, it MAY re-attempt
registration without using the outbound mechanism (subject to local
policy at the client). If the client has one or more alternate
outbound proxies available, it MAY re-attempt registration through
such outbound proxies. See Section 11.6 for more information on the
439 response code.
4.2.2. Subsequent REGISTER Requests
Registrations for refreshing a binding and for removing a binding use
the same instance-id and reg-id values as the corresponding initial
registration where the binding was added. Registrations that merely
refresh an existing binding are sent over the same flow as the
original registration where the binding was added.
If a re-registration is rejected with a recoverable error response,
for example by a 503 (Service Unavailable) containing a Retry-After
header, the UAC SHOULD NOT tear down the corresponding flow if the
flow uses a connection-oriented transport such as TCP. As long as
"pongs" are received in response to "pings", the flow SHOULD be kept
active until a non-recoverable error response is received. This
prevents unnecessary closing and opening of connections.
Jennings, et al. Standards Track [Page 16]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
4.2.3. Third-Party Registrations
In an initial registration or re-registration, a UA MUST NOT include
a "reg-id" header field parameter in the Contact header field if the
registering UA is not the same instance as the UA referred to by the
target Contact header field. (This practice is occasionally used to
install forwarding policy into registrars.)
A UAC also MUST NOT include an instance-id feature tag or "reg-id"
Contact header field parameter in a request to un-register all
Contacts (a single Contact header field value with the value of "*").
4.3. Sending Non-REGISTER Requests
When a UAC is about to send a request, it first performs normal
processing to select the next hop URI. The UA can use a variety of
techniques to compute the route set and accordingly the next hop URI.
Discussion of these techniques is outside the scope of this document.
UAs that support this specification SHOULD include the outbound
option tag in a Supported header field in a request that is not a
REGISTER request.
The UAC performs normal DNS resolution on the next hop URI (as
described in [RFC3263]) to find a protocol, IP address, and port.
For protocols that don't use TLS, if the UAC has an existing flow to
this IP address, and port with the correct protocol, then the UAC
MUST use the existing connection. For TLS protocols, there MUST also
be a match between the host production in the next hop and one of the
URIs contained in the subjectAltName in the peer certificate. If the
UAC cannot use one of the existing flows, then it SHOULD form a new
flow by sending a datagram or opening a new connection to the next
hop, as appropriate for the transport protocol.
Typically, a UAC using the procedures of this document and sending a
dialog-forming request will want all subsequent requests in the
dialog to arrive over the same flow. If the UAC is using a Globally
Routable UA URI (GRUU) [RFC5627] that was instantiated using a
Contact header field value that included an "ob" parameter, the UAC
sends the request over the flow used for registration, and subsequent
requests will arrive over that same flow. If the UAC is not using
such a GRUU, then the UAC adds an "ob" parameter to its Contact
header field value. This will cause all subsequent requests in the
dialog to arrive over the flow instantiated by the dialog-forming
request. This case is typical when the request is sent prior to
registration, such as in the initial subscription dialog for the
configuration framework [CONFIG-FMWK].
Jennings, et al. Standards Track [Page 17]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Note: If the UAC wants a UDP flow to work through NATs or
firewalls, it still needs to put the 'rport' parameter [RFC3581]
in its Via header field value, and send from the port it is
prepared to receive on. More general information about NAT
traversal in SIP is described in [NAT-SCEN].
4.4. Keep-Alives and Detecting Flow Failure
Keep-alives are used for refreshing NAT/firewall bindings and
detecting flow failure. Flows can fail for many reasons including
the rebooting of NATs and the crashing of edge proxies.
As described in Section 4.2, a UA that registers will begin sending
keep-alives after an appropriate registration response. A UA that
does not register (for example, a PSTN gateway behind a firewall) can
also send keep-alives under certain circumstances.
Under specific circumstances, a UAC might be allowed to send STUN
keep-alives even if the procedures in Section 4.2 were not completed,
provided that there is an explicit indication that the target first-
hop SIP node supports STUN keep-alives. For example, this applies to
a non-registering UA or to a case where the UA registration
succeeded, but the response did not include the outbound option-tag
in the Require header field.
Note: A UA can "always" send a double CRLF (a "ping") over
connection-oriented transports as this is already allowed by
Section 7.5 of [RFC3261]. However a UA that did not register
using outbound registration cannot expect a CRLF in response (a
"pong") unless the UA has an explicit indication that CRLF keep-
alives are supported as described in this section. Likewise, a UA
that did not successfully register with outbound procedures needs
explicit indication that the target first-hop SIP node supports
STUN keep-alives before it can send any STUN messages.
A configuration option indicating keep-alive support for a specific
target is considered an explicit indication. If these conditions are
satisfied, the UA sends its keep-alives according to the same
guidelines as those used when UAs register; these guidelines are
described below.
The UA needs to detect when a specific flow fails. The UA actively
tries to detect failure by periodically sending keep-alive messages
using one of the techniques described in Sections 4.4.1 or 4.4.2. If
a flow with a registration has failed, the UA follows the procedures
in Section 4.2 to form a new flow to replace the failed one.
Jennings, et al. Standards Track [Page 18]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
When a successful registration response contains the Flow-Timer
header field, the value of this header field is the number of seconds
the server is prepared to wait without seeing keep-alives before it
could consider the corresponding flow dead. Note that the server
would wait for an amount of time larger than the Flow-Timer in order
to have a grace period to account for transport delay. The UA MUST
send keep-alives at least as often as this number of seconds. If the
UA uses the server-recommended keep-alive frequency it SHOULD send
its keep-alives so that the interval between each keep-alive is
randomly distributed between 80% and 100% of the server-provided
time. For example, if the server suggests 120 seconds, the UA would
send each keep-alive with a different frequency between 95 and 120
seconds.
If no Flow-Timer header field was present in a register response for
this flow, the UA can send keep-alives at its discretion. The
sections below provide RECOMMENDED default values for these keep-
alives.
The client needs to perform normal [RFC3263] SIP DNS resolution on
the URI from the outbound-proxy-set to pick a transport. Once a
transport is selected, the UA selects the keep-alive approach that is
recommended for that transport.
Section 4.4.1 describes a keep-alive mechanism for connection-
oriented transports such as TCP or SCTP. Section 4.4.2 describes a
keep-alive mechanism for connection-less transports such as UDP.
Support for other transports such as DCCP [RFC4340] is for further
study.
4.4.1. Keep-Alive with CRLF
This approach MUST only be used with connection oriented transports
such as TCP or SCTP; it MUST NOT be used with connection-less
transports such as UDP.
A User Agent that forms flows checks if the configured URI to which
the UA is connecting resolves to a connection-oriented transport
(e.g., TCP and TLS over TCP).
For this mechanism, the client "ping" is a double-CRLF sequence, and
the server "pong" is a single CRLF, as defined in the ABNF below:
CRLF = CR LF
double-CRLF = CR LF CR LF
CR = %x0D
LF = %x0A
Jennings, et al. Standards Track [Page 19]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The "ping" and "pong" need to be sent between SIP messages and cannot
be sent in the middle of a SIP message. If sending over TLS, the
CRLFs are sent inside the TLS protected channel. If sending over a
SigComp [RFC3320] compressed data stream, the CRLF keep-alives are
sent inside the compressed stream. The double CRLF is considered a
single SigComp message. The specific mechanism for representing
these characters is an implementation-specific matter to be handled
by the SigComp compressor at the sending end.
If a pong is not received within 10 seconds after sending a ping (or
immediately after processing any incoming message being received when
that 10 seconds expires), then the client MUST treat the flow as
failed. Clients MUST support this CRLF keep-alive.
Note: This value of 10-second timeout was selected to be long
enough that it allows plenty of time for a server to send a
response even if the server is temporarily busy with an
administrative activity. At the same time, it was selected to be
small enough that a UA registered to two redundant servers with
unremarkable hardware uptime could still easily provide very high
levels of overall reliability. Although some Internet protocols
are designed for round-trip times over 10 seconds, SIP for real-
time communications is not really usable in these type of
environments as users often abandon calls before waiting much more
than a few seconds.
When a Flow-Timer header field is not provided in the most recent
success registration response, the proper selection of keep-alive
frequency is primarily a trade-off between battery usage and
availability. The UA MUST select a random number between a fixed or
configurable upper bound and a lower bound, where the lower bound is
20% less then the upper bound. The fixed upper bound or the default
configurable upper bound SHOULD be 120 seconds (95 seconds for the
lower bound) where battery power is not a concern and 840 seconds
(672 seconds for the lower bound) where battery power is a concern.
The random number will be different for each keep-alive "ping".
Note on selection of time values: the 120-second upper bound was
chosen based on the idea that for a good user experience, failures
normally will be detected in this amount of time and a new
connection will be set up. The 14-minute upper bound for battery-
powered devices was selected based on NATs with TCP timeouts as
low as 15 minutes. Operators that wish to change the relationship
between load on servers and the expected time that a user might
not receive inbound communications will probably adjust this time.
The 95-second lower bound was chosen so that the jitter introduced
will result in a relatively even load on the servers after 30
minutes.
Jennings, et al. Standards Track [Page 20]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
4.4.2. Keep-Alive with STUN
This approach MUST only be used with connection-less transports, such
as UDP; it MUST NOT be used for connection-oriented transports such
as TCP and SCTP.
A User Agent that forms flows checks if the configured URI to which
the UA is connecting resolves to use the UDP transport. The UA can
periodically perform keep-alive checks by sending STUN [RFC5389]
Binding Requests over the flow as described in Section 8. Clients
MUST support STUN-based keep-alives.
When a Flow-Timer header field is not included in a successful
registration response, the time between each keep-alive request
SHOULD be a random number between 24 and 29 seconds.
Note on selection of time values: the upper bound of 29 seconds
was selected, as many NATs have UDP timeouts as low as 30 seconds.
The 24-second lower bound was selected so that after 10 minutes
the jitter introduced by different timers will make the keep-alive
requests unsynchronized to evenly spread the load on the servers.
Note that the short NAT timeouts with UDP have a negative impact
on battery life.
If a STUN Binding Error Response is received, or if no Binding
Response is received after 7 retransmissions (16 times the STUN "RTO"
timer -- where RTO is an estimate of round-trip time), the UA
considers the flow failed. If the XOR-MAPPED-ADDRESS in the STUN
Binding Response changes, the UA MUST treat this event as a failure
on the flow.
4.5. Flow Recovery
When a flow used for registration (through a particular URI in the
outbound-proxy-set) fails, the UA needs to form a new flow to replace
the old flow and replace any registrations that were previously sent
over this flow. Each new registration MUST have the same reg-id
value as the registration it replaces. This is done in much the same
way as forming a brand new flow as described in Section 4.2; however,
if there is a failure in forming this flow, the UA needs to wait a
certain amount of time before retrying to form a flow to this
particular next hop.
The amount of time to wait depends if the previous attempt at
establishing a flow was successful. For the purposes of this
section, a flow is considered successful if outbound registration
succeeded, and if keep-alives are in use on this flow, at least one
subsequent keep-alive response was received.
Jennings, et al. Standards Track [Page 21]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The number of seconds to wait is computed in the following way. If
all of the flows to every URI in the outbound proxy set have failed,
the base-time is set to a lower value (with a default of 30 seconds);
otherwise, in the case where at least one of the flows has not
failed, the base-time is set to a higher value (with a default of 90
seconds). The upper-bound wait time (W) is computed by taking two
raised to the power of the number of consecutive registration
failures for that URI, and multiplying this by the base-time, up to a
configurable maximum time (with a default of 1800 seconds).
W = min (max-time, (base-time * (2 ^ consecutive-failures)))
These times MAY be configurable in the UA. The three times are:
o max-time with a default of 1800 seconds
o base-time (if all failed) with a default of 30 seconds
o base-time (if all have not failed) with a default of 90 seconds
For example, if the base-time is 30 seconds, and there were three
failures, then the upper-bound wait time is min(1800, 30*(2^3)) or
240 seconds. The actual amount of time the UA waits before retrying
registration (the retry delay time) is computed by selecting a
uniform random time between 50 and 100% of the upper-bound wait time.
The UA MUST wait for at least the value of the retry delay time
before trying another registration to form a new flow for that URI (a
503 response to an earlier failed registration attempt with a Retry-
After header field value may cause the UA to wait longer).
To be explicitly clear on the boundary conditions: when the UA boots,
it immediately tries to register. If this fails and no registration
on other flows succeed, the first retry happens somewhere between 30
and 60 seconds after the failure of the first registration request.
If the number of consecutive-failures is large enough that the
maximum of 1800 seconds is reached, the UA will keep trying
indefinitely with a random time of 15 to 30 minutes between each
attempt.
5. Edge Proxy Procedures
5.1. Processing Register Requests
When an edge proxy receives a registration request with a "reg-id"
header field parameter in the Contact header field, it needs to
determine if it (the edge proxy) will have to be visited for any
subsequent requests sent to the User Agent identified in the Contact
header field, or not. If the edge proxy is the first hop, as
Jennings, et al. Standards Track [Page 22]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
indicated by the Via header field, it MUST insert its URI in a Path
header field value as described in [RFC3327]. If it is not the first
hop, it might still decide to add itself to the Path header based on
local policy. In addition, if the edge proxy is the first SIP node
after the UAC, the edge proxy either MUST store a "flow token"
(containing information about the flow from the previous hop) in its
Path URI or reject the request. The flow token MUST be an identifier
that is unique to this network flow. The flow token MAY be placed in
the userpart of the URI. In addition, the first node MUST include an
"ob" URI parameter in its Path header field value. If the edge proxy
is not the first SIP node after the UAC it MUST NOT place an "ob" URI
parameter in a Path header field value. The edge proxy can determine
if it is the first hop by examining the Via header field.
5.2. Generating Flow Tokens
A trivial but impractical way to satisfy the flow token requirement
in Section 5.1 involves storing a mapping between an incrementing
counter and the connection information; however, this would require
the edge proxy to keep an infeasible amount of state. It is unclear
when this state could be removed, and the approach would have
problems if the proxy crashed and lost the value of the counter. A
stateless example is provided below. A proxy can use any algorithm
it wants as long as the flow token is unique to a flow, the flow can
be recovered from the token, and the token cannot be modified by
attackers.
Example Algorithm: When the proxy boots, it selects a 20-octet
crypto random key called K that only the edge proxy knows. A byte
array, called S, is formed that contains the following information
about the flow the request was received on: an enumeration
indicating the protocol, the local IP address and port, the remote
IP address and port. The HMAC of S is computed using the key K
and the HMAC-SHA1-80 algorithm, as defined in [RFC2104]. The
concatenation of the HMAC and S are base64 encoded, as defined in
[RFC4648], and used as the flow identifier. When using IPv4
addresses, this will result in a 32-octet identifier.
5.3. Forwarding Non-REGISTER Requests
When an edge proxy receives a request, it applies normal routing
procedures with the following additions. If the edge proxy receives
a request where the edge proxy is the host in the topmost Route
header field value, and the Route header field value contains a flow
token, the proxy follows the procedures of this section. Otherwise
the edge proxy skips the procedures in this section, removes itself
from the Route header field, and continues processing the request.
Jennings, et al. Standards Track [Page 23]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The proxy decodes the flow token and compares the flow in the flow
token with the source of the request to determine if this is an
"incoming" or "outgoing" request.
If the flow in the flow token identified by the topmost Route header
field value matches the source IP address and port of the request,
the request is an "outgoing" request; otherwise, it is an "incoming"
request.
5.3.1. Processing Incoming Requests
If the Route header value contains an "ob" URI parameter, the Route
header was probably copied from the Path header in a registration.
If the Route header value contains an "ob" URI parameter, and the
request is a new dialog-forming request, the proxy needs to adjust
the route set to ensure that subsequent requests in the dialog can be
delivered over a valid flow to the UA instance identified by the flow
token.
Note: A simple approach to satisfy this requirement is for the
proxy to add a Record-Route header field value that contains the
flow-token, by copying the URI in the Route header minus the "ob"
parameter.
Next, whether the Route header field contained an "ob" URI parameter
or not, the proxy removes the Route header field value and forwards
the request over the 'logical flow' identified by the flow token,
that is known to deliver data to the specific target UA instance. If
the flow token has been tampered with, the proxy SHOULD send a 403
(Forbidden) response. If the flow no longer exists, the proxy SHOULD
send a 430 (Flow Failed) response to the request.
Proxies that used the example algorithm described in Section 5.2 to
form a flow token follow the procedures below to determine the
correct flow. To decode the flow token, take the flow identifier in
the user portion of the URI and base64 decode it, then verify the
HMAC is correct by recomputing the HMAC and checking that it matches.
If the HMAC is not correct, the request has been tampered with.
5.3.2. Processing Outgoing Requests
For mid-dialog requests to work with outbound UAs, the requests need
to be forwarded over some valid flow to the appropriate UA instance.
If the edge proxy receives an outgoing dialog-forming request, the
edge proxy can use the presence of the "ob" URI parameter in the
UAC's Contact URI (or topmost Route header field) to determine if the
edge proxy needs to assist in mid-dialog request routing.
Jennings, et al. Standards Track [Page 24]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Implementation note: Specific procedures at the edge proxy to
ensure that mid-dialog requests are routed over an existing flow
are not part of this specification. However, an approach such as
having the edge proxy add a Record-Route header with a flow token
is one way to ensure that mid-dialog requests are routed over the
correct flow.
5.4. Edge Proxy Keep-Alive Handling
All edge proxies compliant with this specification MUST implement
support for STUN NAT keep-alives on their SIP UDP ports as described
in Section 8.
When a server receives a double CRLF sequence between SIP messages on
a connection-oriented transport such as TCP or SCTP, it MUST
immediately respond with a single CRLF over the same connection.
The last proxy to forward a successful registration response to a UA
MAY include a Flow-Timer header field if the response contains the
outbound option-tag in a Require header field value in the response.
The reason a proxy would send a Flow-Timer is if it wishes to detect
flow failures proactively and take appropriate action (e.g., log
alarms, provide alternative treatment if incoming requests for the UA
are received, etc.). The server MUST wait for an amount of time
larger than the Flow-Timer in order to have a grace period to account
for transport delay.
6. Registrar Procedures
This specification updates the definition of a binding in [RFC3261],
Section 10 and [RFC3327], Section 5.3.
Registrars that implement this specification MUST support the Path
header mechanism [RFC3327].
When receiving a REGISTER request, the registrar MUST check from its
Via header field if the registrar is the first hop or not. If the
registrar is not the first hop, it MUST examine the Path header of
the request. If the Path header field is missing or it exists but
the first URI does not have an "ob" URI parameter, then outbound
processing MUST NOT be applied to the registration. In this case,
the following processing applies: if the REGISTER request contains
the reg-id and the outbound option tag in a Supported header field,
then the registrar MUST respond to the REGISTER request with a 439
(First Hop Lacks Outbound Support) response; otherwise, the registrar
MUST ignore the "reg-id" parameter of the Contact header. See
Section 11.6 for more information on the 439 response code.
Jennings, et al. Standards Track [Page 25]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
A Contact header field value with an instance-id media feature tag
but no "reg-id" header field parameter is valid (this combination
will result in the creation of a GRUU, as described in the GRUU
specification [RFC5627]), but one with a reg-id but no instance-id is
not valid. If the registrar processes a Contact header field value
with a reg-id but no instance-id, it simply ignores the reg-id
parameter.
A registration containing a "reg-id" header field parameter and a
non-zero expiration is used to register a single UA instance over a
single flow, and can also de-register any Contact header fields with
zero expiration. Therefore, if the Contact header field contains
more than one header field value with a non-zero expiration and any
of these header field values contain a "reg-id" Contact header field
parameter, the entire registration SHOULD be rejected with a 400 (Bad
Request) response. The justification for recommending rejection
versus making it mandatory is that the receiver is allowed by
[RFC3261] to squelch (not respond to) excessively malformed or
malicious messages.
If the Contact header did not contain a "reg-id" Contact header field
parameter or if that parameter was ignored (as described above), the
registrar MUST NOT include the outbound option-tag in the Require
header field of its response.
The registrar MUST be prepared to receive, simultaneously for the
same AOR, some registrations that use instance-id and reg-id and some
registrations that do not. The registrar MAY be configured with
local policy to reject any registrations that do not include the
instance-id and reg-id, or with Path header field values that do not
contain the "ob" URI parameter. If the Contact header field does not
contain a "+sip.instance" Contact header field parameter, the
registrar processes the request using the Contact binding rules in
[RFC3261].
When a "+sip.instance" Contact header field parameter and a "reg-id"
Contact header field parameter are present in a Contact header field
of a REGISTER request (after the Contact header validation as
described above), the corresponding binding is between an AOR and the
combination of the instance-id (from the "+sip.instance" Contact
header parameter) and the value of "reg-id" Contact header field
parameter parameter. The registrar MUST store in the binding the
Contact URI, all the Contact header field parameters, and any Path
header field values. (Even though the Contact URI is not used for
binding comparisons, it is still needed by the authoritative proxy to
form the target set.) Provided that the UAC had included an outbound
option-tag (defined in Section 11.4) in a Supported header field
Jennings, et al. Standards Track [Page 26]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
value in the REGISTER request, the registrar MUST include the
outbound option-tag in a Require header field value in its response
to that REGISTER request.
If the UAC has a direct flow with the registrar, the registrar MUST
store enough information to uniquely identify the network flow over
which the request arrived. For common operating systems with TCP,
this would typically be just the handle to the file descriptor where
the handle would become invalid if the TCP session was closed. For
common operating systems with UDP this would typically be the file
descriptor for the local socket that received the request, the local
interface, and the IP address and port number of the remote side that
sent the request. The registrar MAY store this information by adding
itself to the Path header field with an appropriate flow token.
If the registrar receives a re-registration for a specific
combination of AOR, and instance-id and reg-id values, the registrar
MUST update any information that uniquely identifies the network flow
over which the request arrived if that information has changed, and
SHOULD update the time the binding was last updated.
To be compliant with this specification, registrars that can receive
SIP requests directly from a UAC without intervening edge proxies
MUST implement the same keep-alive mechanisms as edge proxies
(Section 5.4). Registrars with a direct flow with a UA MAY include a
Flow-Timer header in a 2xx class registration response that includes
the outbound option-tag in the Require header.
7. Authoritative Proxy Procedures: Forwarding Requests
When a proxy uses the location service to look up a registration
binding and then proxies a request to a particular contact, it
selects a contact to use normally, with a few additional rules:
o The proxy MUST NOT populate the target set with more than one
contact with the same AOR and instance-id at a time.
o If a request for a particular AOR and instance-id fails with a 430
(Flow Failed) response, the proxy SHOULD replace the failed branch
with another target (if one is available) with the same AOR and
instance-id, but a different reg-id.
o If the proxy receives a final response from a branch other than a
408 (Request Timeout) or a 430 (Flow Failed) response, the proxy
MUST NOT forward the same request to another target representing
the same AOR and instance-id. The targeted instance has already
provided its response.
Jennings, et al. Standards Track [Page 27]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
The proxy uses the next-hop target of the message and the value of
any stored Path header field vector in the registration binding to
decide how to forward and populate the Route header in the request.
If the proxy is co-located with the registrar and stored information
about the flow to the UA that created the binding, then the proxy
MUST send the request over the same 'logical flow' saved with the
binding, since that flow is known to deliver data to the specific
target UA instance's network flow that was saved with the binding.
Implementation note: Typically this means that for TCP, the
request is sent on the same TCP socket that received the REGISTER
request. For UDP, the request is sent from the same local IP
address and port over which the registration was received, to the
same IP address and port from which the REGISTER was received.
If a proxy or registrar receives information from the network that
indicates that no future messages will be delivered on a specific
flow, then the proxy MUST invalidate all the bindings in the target
set that use that flow (regardless of AOR). Examples of this are a
TCP socket closing or receiving a destination unreachable ICMP error
on a UDP flow. Similarly, if a proxy closes a file descriptor, it
MUST invalidate all the bindings in the target set with flows that
use that file descriptor.
8. STUN Keep-Alive Processing
This section describes changes to the SIP transport layer that allow
SIP and STUN [RFC5389] Binding Requests to be mixed over the same
flow. This constitutes a new STUN usage. The STUN messages are used
to verify that connectivity is still available over a UDP flow, and
to provide periodic keep-alives. These STUN keep-alives are always
sent to the next SIP hop. STUN messages are not delivered end-to-
end.
The only STUN messages required by this usage are Binding Requests,
Binding Responses, and Binding Error Responses. The UAC sends
Binding Requests over the same UDP flow that is used for sending SIP
messages. These Binding Requests do not require any STUN attributes.
The corresponding Binding Responses do not require any STUN
attributes except the XOR-MAPPED-ADDRESS. The UAS, proxy, or
registrar responds to a valid Binding Request with a Binding Response
that MUST include the XOR-MAPPED-ADDRESS attribute.
If a server compliant to this section receives SIP requests on a
given interface and UDP port, it MUST also provide a limited version
of a STUN server on the same interface and UDP port.
Jennings, et al. Standards Track [Page 28]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Note: It is easy to distinguish STUN and SIP packets sent over
UDP, because the first octet of a STUN Binding method has a value
of 0 or 1, while the first octet of a SIP message is never a 0 or
1.
Because sending and receiving binary STUN data on the same ports used
for SIP is a significant and non-backwards compatible change to RFC
3261, this section requires a number of checks before sending STUN
messages to a SIP node. If a SIP node sends STUN requests (for
example, due to incorrect configuration) despite these warnings, the
node could be blacklisted for UDP traffic.
A SIP node MUST NOT send STUN requests over a flow unless it has an
explicit indication that the target next-hop SIP server claims to
support this specification. UACs MUST NOT use an ambiguous
configuration option such as "Work through NATs?" or "Do keep-
alives?" to imply next-hop STUN support. A UAC MAY use the presence
of an "ob" URI parameter in the Path header in a registration
response as an indication that its first edge proxy supports the
keep-alives defined in this document.
Note: Typically, a SIP node first sends a SIP request and waits to
receive a 2xx class response over a flow to a new target
destination, before sending any STUN messages. When scheduled for
the next NAT refresh, the SIP node sends a STUN request to the
target.
Once a flow is established, failure of a STUN request (including its
retransmissions) is considered a failure of the underlying flow. For
SIP over UDP flows, if the XOR-MAPPED-ADDRESS returned over the flow
changes, this indicates that the underlying connectivity has changed,
and is considered a flow failure.
The SIP keep-alive STUN usage requires no backwards compatibility
with [RFC3489].
8.1. Use with SigComp
When STUN is used together with SigComp [RFC3320] compressed SIP
messages over the same flow, the STUN messages are simply sent
uncompressed, "outside" of SigComp. This is supported by
multiplexing STUN messages with SigComp messages by checking the two
topmost bits of the message. These bits are always one for SigComp,
or zero for STUN.
Note: All SigComp messages contain a prefix (the five most
significant bits of the first byte are set to one) that does not
occur in UTF-8 [RFC3629] encoded text messages, so for
Jennings, et al. Standards Track [Page 29]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
applications that use this encoding (or ASCII encoding) it is
possible to multiplex uncompressed application messages and
SigComp messages on the same UDP port. The most significant two
bits of every STUN Binding method are both zeroes. This, combined
with the magic cookie, aids in differentiating STUN packets from
other protocols when STUN is multiplexed with other protocols on
the same port.
9. Example Message Flow
Below is an example message flow illustrating most of the concepts
discussed in this specification. In many cases, Via, Content-Length,
and Max-Forwards headers are omitted for brevity and readability.
In these examples, "EP1" and "EP2" are outbound proxies, and "Proxy"
is the authoritativeProxy.
The section is subdivided into independent calls flows; however, they
are structured in sequential order of a hypothetical sequence of call
flows.
9.1. Subscription to Configuration Package
If the outbound proxy set is already configured on Bob's UA, then
this subsection can be skipped. Otherwise, if the outbound proxy set
is learned through the configuration package, Bob's UA sends a
SUBSCRIBE request for the UA profile configuration package
[CONFIG-FMWK]. This request is a poll (Expires is zero). After
receiving the NOTIFY request, Bob's UA fetches the external
configuration using HTTPS (not shown) and obtains a configuration
file that contains the outbound-proxy-set "sip:ep1.example.com;lr"
and "sip:ep2.example.com;lr".
[----example.com domain-------------------------]
Bob EP1 EP2 Proxy Config
| | | | |
1)|SUBSCRIBE->| | | |
2)| |---SUBSCRIBE Event: ua-profile ->|
3)| |<--200 OK -----------------------|
4)|<--200 OK--| | | |
5)| |<--NOTIFY------------------------|
6)|<--NOTIFY--| | | |
7)|---200 OK->| | | |
8)| |---200 OK ---------------------->|
| | | | |
In this example, the DNS server happens to be configured so that sip:
example.com resolves to EP1 and EP2.
Jennings, et al. Standards Track [Page 30]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Example Message #1:
SUBSCRIBE sip:00000000-0000-1000-8000-AABBCCDDEEFF@example.com
SIP/2.0
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bKnlsdkdj2
Max-Forwards: 70
From: <anonymous@example.com>;tag=23324
To: <sip:00000000-0000-1000-8000-AABBCCDDEEFF@example.com>
Call-ID: nSz1TWN54x7My0GvpEBj
CSeq: 1 SUBSCRIBE
Event: ua-profile ;profile-type=device
;vendor="example.com";model="uPhone";version="1.1"
Expires: 0
Supported: path, outbound
Accept: message/external-body, application/x-uPhone-config
Contact: <sip:192.0.2.2;transport=tcp;ob>
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Content-Length: 0
In message #2, EP1 adds the following Record-Route header:
Record-Route:
<sip:GopIKSsn0oGLPXRdV9BAXpT3coNuiGKV@ep1.example.com;lr>
In message #5, the configuration server sends a NOTIFY with an
external URL for Bob to fetch his configuration. The NOTIFY has a
Subscription-State header that ends the subscription.
Message #5
NOTIFY sip:192.0.2.2;transport=tcp;ob SIP/2.0
Via: SIP/2.0/TCP 192.0.2.5;branch=z9hG4bKn81dd2
Max-Forwards: 70
To: <anonymous@example.com>;tag=23324
From: <sip:00000000-0000-1000-8000-AABBCCDDEEFF@example.com>;tag=0983
Call-ID: nSz1TWN54x7My0GvpEBj
CSeq: 1 NOTIFY
Route: <sip:GopIKSsn0oGLPXRdV9BAXpT3coNuiGKV@ep1.example.com;lr>
Subscription-State: terminated;reason=timeout
Event: ua-profile
Content-Type: message/external-body; access-type="URL"
;expiration="Thu, 01 Jan 2009 09:00:00 UTC"
;URL="http://example.com/uPhone.cfg"
;size=9999;hash=10AB568E91245681AC1B
Content-Length: 0
Jennings, et al. Standards Track [Page 31]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
EP1 receives this NOTIFY request, strips off the Route header,
extracts the flow-token, calculates the correct flow, and forwards
the request (message #6) over that flow to Bob.
Bob's UA fetches the configuration file and learns the outbound proxy
set.
9.2. Registration
Now that Bob's UA is configured with the outbound-proxy-set whether
through configuration or using the configuration framework procedures
of the previous section, Bob's UA sends REGISTER requests through
each edge proxy in the set. Once the registrations succeed, Bob's UA
begins sending CRLF keep-alives about every 2 minutes.
Bob EP1 EP2 Proxy Alice
| | | | |
9)|-REGISTER->| | | |
10)| |---REGISTER-->| |
11)| |<----200 OK---| |
12)|<-200 OK---| | | |
13)|----REGISTER---->| | |
14)| | |--REG-->| |
15)| | |<-200---| |
16)|<----200 OK------| | |
| | | | |
| about 120 seconds later... |
| | | | |
17)|--2CRLF--->| | | |
18)|<--CRLF----| | | |
19)|------2CRLF----->| | |
20)|<------CRLF------| | |
| | | | |
In message #9, Bob's UA sends its first registration through the
first edge proxy in the outbound-proxy-set by including a loose
route. The UA includes an instance-id and reg-id in its Contact
header field value. Note the option-tags in the Supported header.
Jennings, et al. Standards Track [Page 32]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Message #9
REGISTER sip:example.com SIP/2.0
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bKnashds7
Max-Forwards: 70
From: Bob <sip:bob@example.com>;tag=7F94778B653B
To: Bob <sip:bob@example.com>
Call-ID: 16CB75F21C70
CSeq: 1 REGISTER
Supported: path, outbound
Route: <sip:ep1.example.com;lr>
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=1
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Content-Length: 0
Message #10 is similar. EP1 removes the Route header field value,
decrements Max-Forwards, and adds its Via header field value. Since
EP1 is the first edge proxy, it adds a Path header with a flow token
and includes the "ob" parameter.
Path: <sip:VskztcQ/S8p4WPbOnHbuyh5iJvJIW3ib@ep1.example.com;lr;ob>
Since the response to the REGISTER (message #11) contains the
outbound option-tag in the Require header field, Bob's UA will know
that the registrar used outbound binding rules. The response also
contains the currently active Contacts, and the Path for the current
registration.
Message #11
SIP/2.0 200 OK
Via: SIP/2.0/TCP 192.0.2.15;branch=z9hG4bKnuiqisi
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bKnashds7
From: Bob <sip:bob@example.com>;tag=7F94778B653B
To: Bob <sip:bob@example.com>;tag=6AF99445E44A
Call-ID: 16CB75F21C70
CSeq: 1 REGISTER
Supported: path, outbound
Require: outbound
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=1;expires=3600
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Path: <sip:VskztcQ/S8p4WPbOnHbuyh5iJvJIW3ib@ep1.example.com;lr;ob>
Content-Length: 0
The second registration through EP2 (message #13) is similar except
that the Call-ID has changed, the reg-id is 2, and the Route header
goes through EP2.
Jennings, et al. Standards Track [Page 33]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Message #13
REGISTER sip:example.com SIP/2.0
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bKnqr9bym
Max-Forwards: 70
From: Bob <sip:bob@example.com>;tag=755285EABDE2
To: Bob <sip:bob@example.com>
Call-ID: E05133BD26DD
CSeq: 1 REGISTER
Supported: path, outbound
Route: <sip:ep2.example.com;lr>
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=2
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Content-Length: 0
Likewise in message #14, EP2 adds a Path header with flow token and
"ob" parameter.
Path: <sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr;ob>
Message #16 tells Bob's UA that outbound registration was successful,
and shows both Contacts. Note that only the Path corresponding to
the current registration is returned.
Message #16
SIP/2.0 200 OK
Via: SIP/2.0/TCP 192.0.2.2;branch=z9hG4bKnqr9bym
From: Bob <sip:bob@example.com>;tag=755285EABDE2
To: Bob <sip:bob@example.com>;tag=49A9AD0B3F6A
Call-ID: E05133BD26DD
Supported: path, outbound
Require: outbound
CSeq: 1 REGISTER
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=1;expires=3600
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=2;expires=3600
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
Path: <sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr;ob>
Content-Length: 0
9.3. Incoming Call and Proxy Crash
In this example, after registration, EP1 crashes and reboots. Before
Bob's UA notices that its flow to EP1 is no longer responding, Alice
calls Bob. Bob's authoritative proxy first tries the flow to EP1,
Jennings, et al. Standards Track [Page 34]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
but EP1 no longer has a flow to Bob, so it responds with a 430 (Flow
Failed) response. The proxy removes the stale registration and tries
the next binding for the same instance.
Bob EP1 EP2 Proxy Alice
| | | | |
| CRASH X | | |
| Reboot | | |
| | | | |
21)| | | |<-INVITE-|
22)| |<---INVITE----| |
23)| |----430------>| |
24)| | |<-INVITE| |
25)|<---INVITE-------| | |
26)|----200 OK------>| | |
27)| | |200 OK->| |
28)| | | |-200 OK->|
29)| | |<----------ACK----|
30)|<---ACK----------| | |
| | | | |
31)| | |<----------BYE----|
32)|<---BYE----------| | |
33)|----200 OK------>| | |
34)| | |--------200 OK--->|
| | | | |
Message #21
INVITE sip:bob@example.com SIP/2.0
To: Bob <sip:bob@example.com>
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
Bob's proxy rewrites the Request-URI to the Contact URI used in Bob's
registration, and places the path for one of the registrations
towards Bob's UA instance into a Route header field. This Route goes
through EP1.
Message #22
INVITE sip:bob@192.0.2.2;transport=tcp SIP/2.0
To: Bob <sip:bob@example.com>
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
Route: <sip:VskztcQ/S8p4WPbOnHbuyh5iJvJIW3ib@ep1.example.com;lr;ob>
Jennings, et al. Standards Track [Page 35]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Since EP1 just rebooted, it does not have the flow described in the
flow token. It returns a 430 (Flow Failed) response.
Message #23
SIP/2.0 430 Flow Failed
To: Bob <sip:bob@example.com>
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
The proxy deletes the binding for this path and tries to forward the
INVITE again, this time with the path through EP2.
Message #24
INVITE sip:bob@192.0.2.2;transport=tcp SIP/2.0
To: Bob <sip:bob@example.com>
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
Route: <sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr;ob>
In message #25, EP2 needs to add a Record-Route header field value,
so that any subsequent in-dialog messages from Alice's UA arrive at
Bob's UA. EP2 can determine it needs to Record-Route since the
request is a dialog-forming request and the Route header contained a
flow token and an "ob" parameter. This Record-Route information is
passed back to Alice's UA in the responses (messages #26, 27, and
28).
Message #25
INVITE sip:bob@192.0.2.2;transport=tcp SIP/2.0
To: Bob <sip:bob@example.com>
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
Record-Route:
<sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr>
Jennings, et al. Standards Track [Page 36]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Message #26
SIP/2.0 200 OK
To: Bob <sip:bob@example.com>;tag=skduk2
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 INVITE
Record-Route:
<sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr>
At this point, both UAs have the correct route-set for the dialog.
Any subsequent requests in this dialog will route correctly. For
example, the ACK request in message #29 is sent from Alice's UA
directly to EP2. The BYE request in message #31 uses the same route-
set.
Message #29
ACK sip:bob@192.0.2.2;transport=tcp SIP/2.0
To: Bob <sip:bob@example.com>;tag=skduk2
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 1 ACK
Route: <sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr>
Message #31
BYE sip:bob@192.0.2.2;transport=tcp SIP/2.0
To: Bob <sip:bob@example.com>;tag=skduk2
From: Alice <sip:alice@a.example>;tag=02935
Call-ID: klmvCxVWGp6MxJp2T2mb
CSeq: 2 BYE
Route: <sip:wazHDLdIMtUg6r0I/oRZ15zx3zHE1w1Z@ep2.example.com;lr>
9.4. Re-Registration
Somewhat later, Bob's UA sends keep-alives to both its edge proxies,
but it discovers that the flow with EP1 failed. Bob's UA re-
registers through EP1 using the same reg-id and Call-ID it previously
used.
Jennings, et al. Standards Track [Page 37]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Bob EP1 EP2 Proxy Alice
| | | | |
35)|------2CRLF----->| | |
36)|<------CRLF------| | |
37)|--2CRLF->X | | | |
| | | | |
38)|-REGISTER->| | | |
39)| |---REGISTER-->| |
40)| |<----200 OK---| |
41)|<-200 OK---| | | |
| | | | |
Message #38
REGISTER sip:example.com SIP/2.0
From: Bob <sip:bob@example.com>;tag=7F94778B653B
To: Bob <sip:bob@example.com>
Call-ID: 16CB75F21C70
CSeq: 2 REGISTER
Supported: path, outbound
Route: <sip:ep1.example.com;lr>
Contact: <sip:bob@192.0.2.2;transport=tcp>;reg-id=1
;+sip.instance="<urn:uuid:00000000-0000-1000-8000-AABBCCDDEEFF>"
In message #39, EP1 inserts a Path header with a new flow token:
Path: <sip:3yJEbr1GYZK9cPYk5Snocez6DzO7w+AX@ep1.example.com;lr;ob>
9.5. Outgoing Call
Finally, Bob makes an outgoing call to Alice. Bob's UA includes an
"ob" parameter in its Contact URI in message #42. EP1 adds a Record-
Route with a flow-token in message #43. The route-set is returned to
Bob in the response (messages #45, 46, and 47), and either Bob or
Alice can send in-dialog requests.
Jennings, et al. Standards Track [Page 38]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Bob EP1 EP2 Proxy Alice
| | | | |
42)|--INVITE-->| | | |
43)| |---INVITE---->| |
44)| | | |-INVITE->|
45)| | | |<--200---|
46)| |<----200 OK---| |
47)|<-200 OK---| | | |
48)|--ACK----->| | | |
49)| |-----ACK--------------->|
| | | | |
50)|-- BYE---->| | | |
51)| |-----------BYE--------->|
52)| |<----------200 OK-------|
53)|<--200 OK--| | | |
| | | | |
Message #42
INVITE sip:alice@a.example SIP/2.0
From: Bob <sip:bob@example.com>;tag=ldw22z
To: Alice <sip:alice@a.example>
Call-ID: 95KGsk2V/Eis9LcpBYy3
CSeq: 1 INVITE
Route: <sip:ep1.example.com;lr>
Contact: <sip:bob@192.0.2.2;transport=tcp;ob>
In message #43, EP1 adds the following Record-Route header.
Record-Route:
<sip:3yJEbr1GYZK9cPYk5Snocez6DzO7w+AX@ep1.example.com;lr>
When EP1 receives the BYE (message #50) from Bob's UA, it can tell
that the request is an "outgoing" request (since the source of the
request matches the flow in the flow token) and simply deletes its
Route header field value and forwards the request on to Alice's UA.
Message #50
BYE sip:alice@a.example SIP/2.0
From: Bob <sip:bob@example.com>;tag=ldw22z
To: Alice <sip:alice@a.example>;tag=plqus8
Call-ID: 95KGsk2V/Eis9LcpBYy3
CSeq: 2 BYE
Route: <sip:3yJEbr1GYZK9cPYk5Snocez6DzO7w+AX@ep1.example.com;lr>
Contact: <sip:bob@192.0.2.2;transport=tcp;ob>
Jennings, et al. Standards Track [Page 39]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
10. Grammar
This specification defines a new header field "Flow-Timer", and new
Contact header field parameters, "reg-id" and "+sip.instance". The
grammar includes the definitions from [RFC3261]. Flow-Timer is an
extension-header from the message-header in the [RFC3261] ABNF.
The ABNF [RFC5234] is:
Flow-Timer = "Flow-Timer" HCOLON 1*DIGIT
contact-params =/ c-p-reg / c-p-instance
c-p-reg = "reg-id" EQUAL 1*DIGIT ; 1 to (2^31 - 1)
c-p-instance = "+sip.instance" EQUAL
DQUOTE "<" instance-val ">" DQUOTE
instance-val = 1*uric ; defined in RFC 3261
The value of the reg-id MUST NOT be 0 and MUST be less than 2^31.
11. IANA Considerations
11.1. Flow-Timer Header Field
This specification defines a new SIP header field "Flow-Timer" whose
syntax is defined in Section 10.
Header Name compact Reference
----------------- ------- ---------
Flow-Timer [RFC5626]
11.2. "reg-id" Contact Header Field Parameter
This specification defines a new Contact header field parameter
called reg-id in the "Header Field Parameters and Parameter Values"
sub-registry as per the registry created by [RFC3968]. The syntax is
defined in Section 10. The required information is:
Predefined
Header Field Parameter Name Values Reference
---------------------- --------------------- ---------- ---------
Contact reg-id No [RFC5626]
Jennings, et al. Standards Track [Page 40]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
11.3. SIP/SIPS URI Parameters
This specification augments the "SIP/SIPS URI Parameters" sub-
registry as per the registry created by [RFC3969]. The required
information is:
Parameter Name Predefined Values Reference
-------------- ----------------- ---------
ob No [RFC5626]
11.4. SIP Option Tag
This specification registers a new SIP option tag, as per the
guidelines in Section 27.1 of [RFC3261].
Name: outbound
Description: This option-tag is used to identify UAs and registrars
that support extensions for Client-Initiated Connections. A UA
places this option in a Supported header to communicate its
support for this extension. A registrar places this option-tag in
a Require header to indicate to the registering User Agent that
the registrar used registrations using the binding rules defined
in this extension.
11.5. 430 (Flow Failed) Response Code
This document registers a new SIP response code (430 Flow Failed), as
per the guidelines in Section 27.4 of [RFC3261]. This response code
is used by an edge proxy to indicate to the Authoritative Proxy that
a specific flow to a UA instance has failed. Other flows to the same
instance could still succeed. The Authoritative Proxy SHOULD attempt
to forward to another target (flow) with the same instance-id and
AOR. Endpoints should never receive a 430 response. If an endpoint
receives a 430 response, it should treat it as a 400 (Bad Request)
per normal procedures, as in Section 8.1.3.2 of [RFC3261]. This
response code is defined by the following information, which has been
added to the method and response-code sub-registry under the SIP
Parameters registry.
Response Code Reference
------------------------------------------ ---------
Request Failure 4xx
430 Flow Failed [RFC5626]
Jennings, et al. Standards Track [Page 41]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
11.6. 439 (First Hop Lacks Outbound Support) Response Code
This document registers a new SIP response code (439 First Hop Lacks
Outbound Support), as per the guidelines in Section 27.4 of
[RFC3261]. This response code is used by a registrar to indicate
that it supports the 'outbound' feature described in this
specification, but that the first outbound proxy that the user is
attempting to register through does not. Note that this response
code is only appropriate in the case that the registering User Agent
advertises support for outbound processing by including the outbound
option tag in a Supported header field. Proxies MUST NOT send a 439
response to any requests that do not contain a "reg-id" parameter and
an outbound option tag in a Supported header field. This response
code is defined by the following information, which has been added to
the method and response-code sub-registry under the SIP Parameters
registry.
Response Code Reference
------------------------------------------ ---------
Request Failure 4xx
439 First Hop Lacks Outbound Support [RFC&rfc.number;]
11.7. Media Feature Tag
This section registers a new media feature tag, per the procedures
defined in [RFC2506]. The tag is placed into the sip tree, which is
defined in [RFC3840].
Media feature tag name: sip.instance
ASN.1 Identifier: 23
Summary of the media feature indicated by this tag: This feature tag
contains a string containing a URN that indicates a unique
identifier associated with the UA instance registering the
Contact.
Values appropriate for use with this feature tag: String (equality
relationship).
The feature tag is intended primarily for use in the following
applications, protocols, services, or negotiation mechanisms:
This feature tag is most useful in a communications application,
for describing the capabilities of a device, such as a phone or
PDA.
Examples of typical use: Routing a call to a specific device.
Jennings, et al. Standards Track [Page 42]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Related standards or documents: RFC 5626
Security Considerations: This media feature tag can be used in ways
which affect application behaviors. For example, the SIP caller
preferences extension [RFC3841] allows for call routing decisions
to be based on the values of these parameters. Therefore, if an
attacker can modify the values of this tag, they might be able to
affect the behavior of applications. As a result, applications
that utilize this media feature tag SHOULD provide a means for
ensuring its integrity. Similarly, this feature tag should only
be trusted as valid when it comes from the user or User Agent
described by the tag. As a result, protocols for conveying this
feature tag SHOULD provide a mechanism for guaranteeing
authenticity.
12. Security Considerations
One of the key security concerns in this work is making sure that an
attacker cannot hijack the sessions of a valid user and cause all
calls destined to that user to be sent to the attacker. Note that
the intent is not to prevent existing active attacks on SIP UDP and
TCP traffic, but to ensure that no new attacks are added by
introducing the outbound mechanism.
The simple case is when there are no edge proxies. In this case, the
only time an entry can be added to the routing for a given AOR is
when the registration succeeds. SIP already protects against
attackers being able to successfully register, and this scheme relies
on that security. Some implementers have considered the idea of just
saving the instance-id without relating it to the AOR with which it
registered. This idea will not work because an attacker's UA can
impersonate a valid user's instance-id and hijack that user's calls.
The more complex case involves one or more edge proxies. When a UA
sends a REGISTER request through an edge proxy on to the registrar,
the edge proxy inserts a Path header field value. If the
registration is successfully authenticated, the registrar stores the
value of the Path header field. Later, when the registrar forwards a
request destined for the UA, it copies the stored value of the Path
header field into the Route header field of the request and forwards
the request to the edge proxy.
The only time an edge proxy will route over a particular flow is when
it has received a Route header that has the flow identifier
information that it has created. An incoming request would have
gotten this information from the registrar. The registrar will only
save this information for a given AOR if the registration for the AOR
has been successful; and the registration will only be successful if
Jennings, et al. Standards Track [Page 43]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
the UA can correctly authenticate. Even if an attacker has spoofed
some bad information in the Path header sent to the registrar, the
attacker will not be able to get the registrar to accept this
information for an AOR that does not belong to the attacker. The
registrar will not hand out this bad information to others, and
others will not be misled into contacting the attacker.
The Security Considerations discussed in [RFC3261] and [RFC3327] are
also relevant to this document. For the security considerations of
generating flow tokens, please also see Section 5.2. A discussion of
preventing the avalanche restart problem is in Section 4.5.
This document does not change the mandatory-to-implement security
mechanisms in SIP. User Agents are already required to implement
Digest authentication while support of TLS is recommended; proxy
servers are already required to implement Digest and TLS.
13. Operational Notes on Transports
This entire section is non-normative.
[RFC3261] requires proxies, registrars, and User Agents to implement
both TCP and UDP but deployments can chose which transport protocols
they want to use. Deployments need to be careful in choosing what
transports to use. Many SIP features and extensions, such as large
presence notification bodies, result in SIP requests that can be too
large to be reasonably transported over UDP. [RFC3261] states that
when a request is too large for UDP, the device sending the request
attempts to switch over to TCP. It is important to note that when
using outbound, this will only work if the UA has formed both UDP and
TCP outbound flows. This specification allows the UA to do so, but
in most cases it will probably make more sense for the UA to form a
TCP outbound connection only, rather than forming both UDP and TCP
flows. One of the key reasons that many deployments choose not to
use TCP has to do with the difficulty of building proxies that can
maintain a very large number of active TCP connections. Many
deployments today use SIP in such a way that the messages are small
enough that they work over UDP but they can not take advantage of all
the functionality SIP offers. Deployments that use only UDP outbound
connections are going to fail with sufficiently large SIP messages.
14. Requirements
This specification was developed to meet the following requirements:
1. Must be able to detect that a UA supports these mechanisms.
2. Support UAs behind NATs.
Jennings, et al. Standards Track [Page 44]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
3. Support TLS to a UA without a stable DNS name or IP address.
4. Detect failure of a connection and be able to correct for this.
5. Support many UAs simultaneously rebooting.
6. Support a NAT rebooting or resetting.
7. Minimize initial startup load on a proxy.
8. Support architectures with edge proxies.
15. Acknowledgments
Francois Audet acted as document shepherd for this document, tracking
hundreds of comments and incorporating many grammatical fixes as well
as prodding the editors to "get on with it". Jonathan Rosenberg,
Erkki Koivusalo, and Byron Campen provided many comments and useful
text. Dave Oran came up with the idea of using the most recent
registration first in the proxy. Alan Hawrylyshen co-authored the
document that formed the initial text of this specification.
Additionally, many of the concepts here originated at a connection
reuse meeting at IETF 60 that included the authors, Jon Peterson,
Jonathan Rosenberg, Alan Hawrylyshen, and Paul Kyzivat. The TCP
design team consisting of Chris Boulton, Scott Lawrence, Rajnish
Jain, Vijay K. Gurbani, and Ganesh Jayadevan provided input and text.
Nils Ohlmeier provided many fixes and initial implementation
experience. In addition, thanks to the following folks for useful
comments: Francois Audet, Flemming Andreasen, Mike Hammer, Dan Wing,
Srivatsa Srinivasan, Dale Worely, Juha Heinanen, Eric Rescorla,
Lyndsay Campbell, Christer Holmberg, Kevin Johns, Jeroen van Bemmel,
Derek MacDonald, Dean Willis, and Robert Sparks.
16. References
16.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2141] Moats, R., "URN Syntax", RFC 2141, May 1997.
[RFC2506] Holtman, K., Mutz, A., and T. Hardie, "Media Feature
Tag Registration Procedure", BCP 31, RFC 2506,
March 1999.
Jennings, et al. Standards Track [Page 45]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
[RFC3261] Rosenberg, J., Schulzrinne, H., Camarillo, G.,
Johnston, A., Peterson, J., Sparks, R., Handley, M.,
and E. Schooler, "SIP: Session Initiation Protocol",
RFC 3261, June 2002.
[RFC3263] Rosenberg, J. and H. Schulzrinne, "Session Initiation
Protocol (SIP): Locating SIP Servers", RFC 3263,
June 2002.
[RFC3327] Willis, D. and B. Hoeneisen, "Session Initiation
Protocol (SIP) Extension Header Field for Registering
Non-Adjacent Contacts", RFC 3327, December 2002.
[RFC3581] Rosenberg, J. and H. Schulzrinne, "An Extension to the
Session Initiation Protocol (SIP) for Symmetric
Response Routing", RFC 3581, August 2003.
[RFC3629] Yergeau, F., "UTF-8, a transformation format of ISO
10646", STD 63, RFC 3629, November 2003.
[RFC3840] Rosenberg, J., Schulzrinne, H., and P. Kyzivat,
"Indicating User Agent Capabilities in the Session
Initiation Protocol (SIP)", RFC 3840, August 2004.
[RFC3841] Rosenberg, J., Schulzrinne, H., and P. Kyzivat,
"Caller Preferences for the Session Initiation
Protocol (SIP)", RFC 3841, August 2004.
[RFC3968] Camarillo, G., "The Internet Assigned Number Authority
(IANA) Header Field Parameter Registry for the Session
Initiation Protocol (SIP)", BCP 98, RFC 3968,
December 2004.
[RFC3969] Camarillo, G., "The Internet Assigned Number Authority
(IANA) Uniform Resource Identifier (URI) Parameter
Registry for the Session Initiation Protocol (SIP)",
BCP 99, RFC 3969, December 2004.
[RFC4122] Leach, P., Mealling, M., and R. Salz, "A Universally
Unique IDentifier (UUID) URN Namespace", RFC 4122,
July 2005.
[RFC5234] Crocker, D. and P. Overell, "Augmented BNF for Syntax
Specifications: ABNF", STD 68, RFC 5234, January 2008.
[RFC5389] Rosenberg, J., Mahy, R., Matthews, P., and D. Wing,
"Session Traversal Utilities for NAT (STUN)",
RFC 5389, October 2008.
Jennings, et al. Standards Track [Page 46]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
16.2. Informative References
[CONFIG-FMWK] Petrie, D. and S. Channabasappa, Ed., "A Framework for
Session Initiation Protocol User Agent Profile
Delivery", Work in Progress, February 2008.
[NAT-SCEN] Boulton, C., Rosenberg, J., Camarillo, G., and F.
Audet, "Best Current Practices for NAT Traversal for
Client-Server SIP", Work in Progress, September 2008.
[RFC0768] Postel, J., "User Datagram Protocol", STD 6, RFC 768,
August 1980.
[RFC0793] Postel, J., "Transmission Control Protocol", STD 7,
RFC 793, September 1981.
[RFC1035] Mockapetris, P., "Domain names - implementation and
specification", STD 13, RFC 1035, November 1987.
[RFC2104] Krawczyk, H., Bellare, M., and R. Canetti, "HMAC:
Keyed-Hashing for Message Authentication", RFC 2104,
February 1997.
[RFC2131] Droms, R., "Dynamic Host Configuration Protocol",
RFC 2131, March 1997.
[RFC2782] Gulbrandsen, A., Vixie, P., and L. Esibov, "A DNS RR
for specifying the location of services (DNS SRV)",
RFC 2782, February 2000.
[RFC3320] Price, R., Bormann, C., Christoffersson, J., Hannu,
H., Liu, Z., and J. Rosenberg, "Signaling Compression
(SigComp)", RFC 3320, January 2003.
[RFC3489] Rosenberg, J., Weinberger, J., Huitema, C., and R.
Mahy, "STUN - Simple Traversal of User Datagram
Protocol (UDP) Through Network Address Translators
(NATs)", RFC 3489, March 2003.
[RFC3986] Berners-Lee, T., Fielding, R., and L. Masinter,
"Uniform Resource Identifier (URI): Generic Syntax",
STD 66, RFC 3986, January 2005.
[RFC4340] Kohler, E., Handley, M., and S. Floyd, "Datagram
Congestion Control Protocol (DCCP)", RFC 4340,
March 2006.
Jennings, et al. Standards Track [Page 47]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
[RFC4648] Josefsson, S., "The Base16, Base32, and Base64 Data
Encodings", RFC 4648, October 2006.
[RFC4960] Stewart, R., "Stream Control Transmission Protocol",
RFC 4960, September 2007.
[RFC5246] Dierks, T. and E. Rescorla, "The Transport Layer
Security (TLS) Protocol Version 1.2", RFC 5246,
August 2008.
[RFC5627] Rosenberg, J., "Obtaining and Using Globally Routable
User Agent URIs (GRUUs) in the Session Initiation
Protocol (SIP)", RFC 5627, October 2009.
Jennings, et al. Standards Track [Page 48]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Appendix A. Default Flow Registration Backoff Times
The base-time used for the flow re-registration backoff times
described in Section 4.5 are configurable. If the base-time-all-fail
value is set to the default of 30 seconds and the base-time-not-
failed value is set to the default of 90 seconds, the following table
shows the resulting amount of time the UA will wait to retry
registration.
+-------------------+--------------------+---------------------+
| # of reg failures | all flows unusable | > 1 non-failed flow |
+-------------------+--------------------+---------------------+
| 0 | 0 s | 0 s |
| 1 | 30-60 s | 90-180 s |
| 2 | 1-2 min | 3-6 min |
| 3 | 2-4 min | 6-12 min |
| 4 | 4-8 min | 12-24 min |
| 5 | 8-16 min | 15-30 min |
| 6 or more | 15-30 min | 15-30 min |
+-------------------+--------------------+---------------------+
Appendix B. ABNF
This appendix contains the ABNF defined earlier in this document.
CRLF = CR LF
double-CRLF = CR LF CR LF
CR = %x0D
LF = %x0A
Flow-Timer = "Flow-Timer" HCOLON 1*DIGIT
contact-params =/ c-p-reg / c-p-instance
c-p-reg = "reg-id" EQUAL 1*DIGIT ; 1 to (2^31 - 1)
c-p-instance = "+sip.instance" EQUAL
DQUOTE "<" instance-val ">" DQUOTE
instance-val = 1*uric ; defined in RFC 3261
Jennings, et al. Standards Track [Page 49]
^L
RFC 5626 Client-Initiated Connections in SIP October 2009
Authors' Addresses
Cullen Jennings (editor)
Cisco Systems
170 West Tasman Drive
Mailstop SJC-21/2
San Jose, CA 95134
USA
Phone: +1 408 902-3341
EMail: fluffy@cisco.com
Rohan Mahy (editor)
Unaffiliated
EMail: rohan@ekabal.com
Francois Audet (editor)
Skype Labs
EMail: francois.audet@skypelabs.com
Jennings, et al. Standards Track [Page 50]
^L
|