summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc7348.txt
blob: e3073b280d8499185fb3f5b4a52062b830f65773 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
Independent Submission                                     M. Mahalingam
Request for Comments: 7348                                     Storvisor
Category: Informational                                          D. Dutt
ISSN: 2070-1721                                         Cumulus Networks
                                                                 K. Duda
                                                                  Arista
                                                              P. Agarwal
                                                                Broadcom
                                                              L. Kreeger
                                                                   Cisco
                                                              T. Sridhar
                                                                  VMware
                                                              M. Bursell
                                                                   Intel
                                                               C. Wright
                                                                 Red Hat
                                                             August 2014


       Virtual eXtensible Local Area Network (VXLAN): A Framework
   for Overlaying Virtualized Layer 2 Networks over Layer 3 Networks

Abstract

   This document describes Virtual eXtensible Local Area Network
   (VXLAN), which is used to address the need for overlay networks
   within virtualized data centers accommodating multiple tenants.  The
   scheme and the related protocols can be used in networks for cloud
   service providers and enterprise data centers.  This memo documents
   the deployed VXLAN protocol for the benefit of the Internet
   community.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This is a contribution to the RFC Series, independently of any other
   RFC stream.  The RFC Editor has chosen to publish this document at
   its discretion and makes no statement about its value for
   implementation or deployment.  Documents approved for publication by
   the RFC Editor are not a candidate for any level of Internet
   Standard; see Section 2 of RFC 5741.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc7348.




Mahalingam, et al.            Informational                     [Page 1]
^L
RFC 7348                          VXLAN                      August 2014


Copyright Notice

   Copyright (c) 2014 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.

Table of Contents

   1. Introduction ....................................................3
      1.1. Acronyms and Definitions ...................................4
   2. Conventions Used in This Document ...............................4
   3. VXLAN Problem Statement .........................................5
      3.1. Limitations Imposed by Spanning Tree and VLAN Ranges .......5
      3.2. Multi-tenant Environments ..................................5
      3.3. Inadequate Table Sizes at ToR Switch .......................6
   4. VXLAN ...........................................................6
      4.1. Unicast VM-to-VM Communication .............................7
      4.2. Broadcast Communication and Mapping to Multicast ...........8
      4.3. Physical Infrastructure Requirements .......................9
   5. VXLAN Frame Format .............................................10
   6. VXLAN Deployment Scenarios .....................................14
      6.1. Inner VLAN Tag Handling ...................................18
   7. Security Considerations ........................................18
   8. IANA Considerations ............................................19
   9. References .....................................................19
      9.1. Normative References ......................................19
      9.2. Informative References ....................................20
   10. Acknowledgments ...............................................21

















Mahalingam, et al.            Informational                     [Page 2]
^L
RFC 7348                          VXLAN                      August 2014


1.  Introduction

   Server virtualization has placed increased demands on the physical
   network infrastructure.  A physical server now has multiple Virtual
   Machines (VMs) each with its own Media Access Control (MAC) address.
   This requires larger MAC address tables in the switched Ethernet
   network due to potential attachment of and communication among
   hundreds of thousands of VMs.

   In the case when the VMs in a data center are grouped according to
   their Virtual LAN (VLAN), one might need thousands of VLANs to
   partition the traffic according to the specific group to which the VM
   may belong.  The current VLAN limit of 4094 is inadequate in such
   situations.

   Data centers are often required to host multiple tenants, each with
   their own isolated network domain.  Since it is not economical to
   realize this with dedicated infrastructure, network administrators
   opt to implement isolation over a shared network.  In such scenarios,
   a common problem is that each tenant may independently assign MAC
   addresses and VLAN IDs leading to potential duplication of these on
   the physical network.

   An important requirement for virtualized environments using a Layer 2
   physical infrastructure is having the Layer 2 network scale across
   the entire data center or even between data centers for efficient
   allocation of compute, network, and storage resources.  In such
   networks, using traditional approaches like the Spanning Tree
   Protocol (STP) for a loop-free topology can result in a large number
   of disabled links.

   The last scenario is the case where the network operator prefers to
   use IP for interconnection of the physical infrastructure (e.g., to
   achieve multipath scalability through Equal-Cost Multipath (ECMP),
   thus avoiding disabled links).  Even in such environments, there is a
   need to preserve the Layer 2 model for inter-VM communication.

   The scenarios described above lead to a requirement for an overlay
   network.  This overlay is used to carry the MAC traffic from the
   individual VMs in an encapsulated format over a logical "tunnel".

   This document details a framework termed "Virtual eXtensible Local
   Area Network (VXLAN)" that provides such an encapsulation scheme to
   address the various requirements specified above.  This memo
   documents the deployed VXLAN protocol for the benefit of the Internet
   community.





Mahalingam, et al.            Informational                     [Page 3]
^L
RFC 7348                          VXLAN                      August 2014


1.1.  Acronyms and Definitions

   ACL      Access Control List

   ECMP     Equal-Cost Multipath

   IGMP     Internet Group Management Protocol

   IHL      Internet Header Length

   MTU      Maximum Transmission Unit

   PIM      Protocol Independent Multicast

   SPB      Shortest Path Bridging

   STP      Spanning Tree Protocol

   ToR      Top of Rack

   TRILL    Transparent Interconnection of Lots of Links

   VLAN     Virtual Local Area Network

   VM       Virtual Machine

   VNI      VXLAN Network Identifier (or VXLAN Segment ID)

   VTEP     VXLAN Tunnel End Point.  An entity that originates and/or
            terminates VXLAN tunnels

   VXLAN    Virtual eXtensible Local Area Network

   VXLAN Segment
            VXLAN Layer 2 overlay network over which VMs communicate

   VXLAN Gateway
            an entity that forwards traffic between VXLANs

2.  Conventions Used in This Document

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].







Mahalingam, et al.            Informational                     [Page 4]
^L
RFC 7348                          VXLAN                      August 2014


3.  VXLAN Problem Statement

   This section provides further details on the areas that VXLAN is
   intended to address.  The focus is on the networking infrastructure
   within the data center and the issues related to them.

3.1.  Limitations Imposed by Spanning Tree and VLAN Ranges

   Current Layer 2 networks use the IEEE 802.1D Spanning Tree Protocol
   (STP) [802.1D] to avoid loops in the network due to duplicate paths.
   STP blocks the use of links to avoid the replication and looping of
   frames.  Some data center operators see this as a problem with Layer
   2 networks in general, since with STP they are effectively paying for
   more ports and links than they can really use.  In addition,
   resiliency due to multipathing is not available with the STP model.
   Newer initiatives, such as TRILL [RFC6325] and SPB [802.1aq], have
   been proposed to help with multipathing and surmount some of the
   problems with STP.  STP limitations may also be avoided by
   configuring servers within a rack to be on the same Layer 3 network,
   with switching happening at Layer 3 both within the rack and between
   racks.  However, this is incompatible with a Layer 2 model for inter-
   VM communication.

   A key characteristic of Layer 2 data center networks is their use of
   Virtual LANs (VLANs) to provide broadcast isolation.  A 12-bit VLAN
   ID is used in the Ethernet data frames to divide the larger Layer 2
   network into multiple broadcast domains.  This has served well for
   many data centers that require fewer than 4094 VLANs.  With the
   growing adoption of virtualization, this upper limit is seeing
   pressure.  Moreover, due to STP, several data centers limit the
   number of VLANs that could be used.  In addition, requirements for
   multi-tenant environments accelerate the need for larger VLAN limits,
   as discussed in Section 3.3.

3.2.  Multi-tenant Environments

   Cloud computing involves on-demand elastic provisioning of resources
   for multi-tenant environments.  The most common example of cloud
   computing is the public cloud, where a cloud service provider offers
   these elastic services to multiple customers/tenants over the same
   physical infrastructure.

   Isolation of network traffic by a tenant could be done via Layer 2 or
   Layer 3 networks.  For Layer 2 networks, VLANs are often used to
   segregate traffic -- so a tenant could be identified by its own VLAN,
   for example.  Due to the large number of tenants that a cloud





Mahalingam, et al.            Informational                     [Page 5]
^L
RFC 7348                          VXLAN                      August 2014


   provider might service, the 4094 VLAN limit is often inadequate.  In
   addition, there is often a need for multiple VLANs per tenant, which
   exacerbates the issue.

   A related use case is cross-pod expansion.  A pod typically consists
   of one or more racks of servers with associated network and storage
   connectivity.  Tenants may start off on a pod and, due to expansion,
   require servers/VMs on other pods, especially in the case when
   tenants on the other pods are not fully utilizing all their
   resources.  This use case requires a "stretched" Layer 2 environment
   connecting the individual servers/VMs.

   Layer 3 networks are not a comprehensive solution for multi-tenancy
   either.  Two tenants might use the same set of Layer 3 addresses
   within their networks, which requires the cloud provider to provide
   isolation in some other form.  Further, requiring all tenants to use
   IP excludes customers relying on direct Layer 2 or non-IP Layer 3
   protocols for inter VM communication.

3.3.  Inadequate Table Sizes at ToR Switch

   Today's virtualized environments place additional demands on the MAC
   address tables of Top-of-Rack (ToR) switches that connect to the
   servers.  Instead of just one MAC address per server link, the ToR
   now has to learn the MAC addresses of the individual VMs (which could
   range in the hundreds per server).  This is needed because traffic
   to/from the VMs to the rest of the physical network will traverse the
   link between the server and the switch.  A typical ToR switch could
   connect to 24 or 48 servers depending upon the number of its server-
   facing ports.  A data center might consist of several racks, so each
   ToR switch would need to maintain an address table for the
   communicating VMs across the various physical servers.  This places a
   much larger demand on the table capacity compared to non-virtualized
   environments.

   If the table overflows, the switch may stop learning new addresses
   until idle entries age out, leading to significant flooding of
   subsequent unknown destination frames.

4.  VXLAN

   VXLAN (Virtual eXtensible Local Area Network) addresses the above
   requirements of the Layer 2 and Layer 3 data center network
   infrastructure in the presence of VMs in a multi-tenant environment.
   It runs over the existing networking infrastructure and provides a
   means to "stretch" a Layer 2 network.  In short, VXLAN is a Layer 2
   overlay scheme on a Layer 3 network.  Each overlay is termed a VXLAN
   segment.  Only VMs within the same VXLAN segment can communicate with



Mahalingam, et al.            Informational                     [Page 6]
^L
RFC 7348                          VXLAN                      August 2014


   each other.  Each VXLAN segment is identified through a 24-bit
   segment ID, termed the "VXLAN Network Identifier (VNI)".  This allows
   up to 16 M VXLAN segments to coexist within the same administrative
   domain.

   The VNI identifies the scope of the inner MAC frame originated by the
   individual VM.  Thus, you could have overlapping MAC addresses across
   segments but never have traffic "cross over" since the traffic is
   isolated using the VNI.  The VNI is in an outer header that
   encapsulates the inner MAC frame originated by the VM.  In the
   following sections, the term "VXLAN segment" is used interchangeably
   with the term "VXLAN overlay network".

   Due to this encapsulation, VXLAN could also be called a tunneling
   scheme to overlay Layer 2 networks on top of Layer 3 networks.  The
   tunnels are stateless, so each frame is encapsulated according to a
   set of rules.  The end point of the tunnel (VXLAN Tunnel End Point or
   VTEP) discussed in the following sections is located within the
   hypervisor on the server that hosts the VM.  Thus, the VNI- and
   VXLAN-related tunnel / outer header encapsulation are known only to
   the VTEP -- the VM never sees it (see Figure 1).  Note that it is
   possible that VTEPs could also be on a physical switch or physical
   server and could be implemented in software or hardware.  One use
   case where the VTEP is a physical switch is discussed in Section 6 on
   VXLAN deployment scenarios.

   The following sections discuss typical traffic flow scenarios in a
   VXLAN environment using one type of control scheme -- data plane
   learning.  Here, the association of VM's MAC to VTEP's IP address is
   discovered via source-address learning.  Multicast is used for
   carrying unknown destination, broadcast, and multicast frames.

   In addition to a learning-based control plane, there are other
   schemes possible for the distribution of the VTEP IP to VM MAC
   mapping information.  Options could include a central
   authority-/directory-based lookup by the individual VTEPs,
   distribution of this mapping information to the VTEPs by the central
   authority, and so on.  These are sometimes characterized as push and
   pull models, respectively.  This document will focus on the data
   plane learning scheme as the control plane for VXLAN.

4.1.  Unicast VM-to-VM Communication

   Consider a VM within a VXLAN overlay network.  This VM is unaware of
   VXLAN.  To communicate with a VM on a different host, it sends a MAC
   frame destined to the target as normal.  The VTEP on the physical
   host looks up the VNI to which this VM is associated.  It then
   determines if the destination MAC is on the same segment and if there



Mahalingam, et al.            Informational                     [Page 7]
^L
RFC 7348                          VXLAN                      August 2014


   is a mapping of the destination MAC address to the remote VTEP.  If
   so, an outer header comprising an outer MAC, outer IP header, and
   VXLAN header (see Figure 1 in Section 5 for frame format) are
   prepended to the original MAC frame.  The encapsulated packet is
   forwarded towards the remote VTEP.  Upon reception, the remote VTEP
   verifies the validity of the VNI and whether or not there is a VM on
   that VNI using a MAC address that matches the inner destination MAC
   address.  If so, the packet is stripped of its encapsulating headers
   and passed on to the destination VM.  The destination VM never knows
   about the VNI or that the frame was transported with a VXLAN
   encapsulation.

   In addition to forwarding the packet to the destination VM, the
   remote VTEP learns the mapping from inner source MAC to outer source
   IP address.  It stores this mapping in a table so that when the
   destination VM sends a response packet, there is no need for an
   "unknown destination" flooding of the response packet.

   Determining the MAC address of the destination VM prior to the
   transmission by the source VM is performed as with non-VXLAN
   environments except as described in Section 4.2.  Broadcast frames
   are used but are encapsulated within a multicast packet, as detailed
   in the Section 4.2.

4.2.  Broadcast Communication and Mapping to Multicast

   Consider the VM on the source host attempting to communicate with the
   destination VM using IP.  Assuming that they are both on the same
   subnet, the VM sends out an Address Resolution Protocol (ARP)
   broadcast frame.  In the non-VXLAN environment, this frame would be
   sent out using MAC broadcast across all switches carrying that VLAN.

   With VXLAN, a header including the VXLAN VNI is inserted at the
   beginning of the packet along with the IP header and UDP header.
   However, this broadcast packet is sent out to the IP multicast group
   on which that VXLAN overlay network is realized.

   To effect this, we need to have a mapping between the VXLAN VNI and
   the IP multicast group that it will use.  This mapping is done at the
   management layer and provided to the individual VTEPs through a
   management channel.  Using this mapping, the VTEP can provide IGMP
   membership reports to the upstream switch/router to join/leave the
   VXLAN-related IP multicast groups as needed.  This will enable
   pruning of the leaf nodes for specific multicast traffic addresses
   based on whether a member is available on this host using the
   specific multicast address (see [RFC4541]).  In addition, use of





Mahalingam, et al.            Informational                     [Page 8]
^L
RFC 7348                          VXLAN                      August 2014


   multicast routing protocols like Protocol Independent Multicast -
   Sparse Mode (PIM-SM see [RFC4601]) will provide efficient multicast
   trees within the Layer 3 network.

   The VTEP will use (*,G) joins.  This is needed as the set of VXLAN
   tunnel sources is unknown and may change often, as the VMs come up /
   go down across different hosts.  A side note here is that since each
   VTEP can act as both the source and destination for multicast
   packets, a protocol like bidirectional PIM (BIDIR-PIM -- see
   [RFC5015]) would be more efficient.

   The destination VM sends a standard ARP response using IP unicast.
   This frame will be encapsulated back to the VTEP connecting the
   originating VM using IP unicast VXLAN encapsulation.  This is
   possible since the mapping of the ARP response's destination MAC to
   the VXLAN tunnel end point IP was learned earlier through the ARP
   request.

   Note that multicast frames and "unknown MAC destination" frames are
   also sent using the multicast tree, similar to the broadcast frames.

4.3.  Physical Infrastructure Requirements

   When IP multicast is used within the network infrastructure, a
   multicast routing protocol like PIM-SM can be used by the individual
   Layer 3 IP routers/switches within the network.  This is used to
   build efficient multicast forwarding trees so that multicast frames
   are only sent to those hosts that have requested to receive them.

   Similarly, there is no requirement that the actual network connecting
   the source VM and destination VM should be a Layer 3 network: VXLAN
   can also work over Layer 2 networks.  In either case, efficient
   multicast replication within the Layer 2 network can be achieved
   using IGMP snooping.

   VTEPs MUST NOT fragment VXLAN packets.  Intermediate routers may
   fragment encapsulated VXLAN packets due to the larger frame size.
   The destination VTEP MAY silently discard such VXLAN fragments.  To
   ensure end-to-end traffic delivery without fragmentation, it is
   RECOMMENDED that the MTUs (Maximum Transmission Units) across the
   physical network infrastructure be set to a value that accommodates
   the larger frame size due to the encapsulation.  Other techniques
   like Path MTU discovery (see [RFC1191] and [RFC1981]) MAY be used to
   address this requirement as well.







Mahalingam, et al.            Informational                     [Page 9]
^L
RFC 7348                          VXLAN                      August 2014


5.  VXLAN Frame Format

   The VXLAN frame format is shown below.  Parsing this from the bottom
   of the frame -- above the outer Frame Check Sequence (FCS), there is
   an inner MAC frame with its own Ethernet header with source,
   destination MAC addresses along with the Ethernet type, plus an
   optional VLAN.  See Section 6 for further details of inner VLAN tag
   handling.

   The inner MAC frame is encapsulated with the following four headers
   (starting from the innermost header):

   VXLAN Header:  This is an 8-byte field that has:

      - Flags (8 bits): where the I flag MUST be set to 1 for a valid
        VXLAN Network ID (VNI).  The other 7 bits (designated "R") are
        reserved fields and MUST be set to zero on transmission and
        ignored on receipt.

      - VXLAN Segment ID/VXLAN Network Identifier (VNI): this is a
        24-bit value used to designate the individual VXLAN overlay
        network on which the communicating VMs are situated.  VMs in
        different VXLAN overlay networks cannot communicate with each
        other.

      - Reserved fields (24 bits and 8 bits): MUST be set to zero on
        transmission and ignored on receipt.

   Outer UDP Header:  This is the outer UDP header with a source port
      provided by the VTEP and the destination port being a well-known
      UDP port.

      -  Destination Port: IANA has assigned the value 4789 for the
         VXLAN UDP port, and this value SHOULD be used by default as the
         destination UDP port.  Some early implementations of VXLAN have
         used other values for the destination port.  To enable
         interoperability with these implementations, the destination
         port SHOULD be configurable.

      -  Source Port:  It is recommended that the UDP source port number
         be calculated using a hash of fields from the inner packet --
         one example being a hash of the inner Ethernet frame's headers.
         This is to enable a level of entropy for the ECMP/load-
         balancing of the VM-to-VM traffic across the VXLAN overlay.
         When calculating the UDP source port number in this manner, it
         is RECOMMENDED that the value be in the dynamic/private port
         range 49152-65535 [RFC6335].




Mahalingam, et al.            Informational                    [Page 10]
^L
RFC 7348                          VXLAN                      August 2014


      -  UDP Checksum: It SHOULD be transmitted as zero.  When a packet
         is received with a UDP checksum of zero, it MUST be accepted
         for decapsulation.  Optionally, if the encapsulating end point
         includes a non-zero UDP checksum, it MUST be correctly
         calculated across the entire packet including the IP header,
         UDP header, VXLAN header, and encapsulated MAC frame.  When a
         decapsulating end point receives a packet with a non-zero
         checksum, it MAY choose to verify the checksum value.  If it
         chooses to perform such verification, and the verification
         fails, the packet MUST be dropped.  If the decapsulating
         destination chooses not to perform the verification, or
         performs it successfully, the packet MUST be accepted for
         decapsulation.

   Outer IP Header:  This is the outer IP header with the source IP
      address indicating the IP address of the VTEP over which the
      communicating VM (as represented by the inner source MAC address)
      is running.  The destination IP address can be a unicast or
      multicast IP address (see Sections 4.1 and 4.2).  When it is a
      unicast IP address, it represents the IP address of the VTEP
      connecting the communicating VM as represented by the inner
      destination MAC address.  For multicast destination IP addresses,
      please refer to the scenarios detailed in Section 4.2.

   Outer Ethernet Header (example):  Figure 1 is an example of an inner
      Ethernet frame encapsulated within an outer Ethernet + IP + UDP +
      VXLAN header.  The outer destination MAC address in this frame may
      be the address of the target VTEP or of an intermediate Layer 3
      router.  The outer VLAN tag is optional.  If present, it may be
      used for delineating VXLAN traffic on the LAN.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1

   Outer Ethernet Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             Outer Destination MAC Address                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Outer Destination MAC Address | Outer Source MAC Address      |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                Outer Source MAC Address                       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |OptnlEthtype = C-Tag 802.1Q    | Outer.VLAN Tag Information    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Ethertype = 0x0800            |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+





Mahalingam, et al.            Informational                    [Page 11]
^L
RFC 7348                          VXLAN                      August 2014


   Outer IPv4 Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |Version|  IHL  |Type of Service|          Total Length         |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Identification        |Flags|      Fragment Offset    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |  Time to Live |Protocl=17(UDP)|   Header Checksum             |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                       Outer Source IPv4 Address               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                   Outer Destination IPv4 Address              |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Outer UDP Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |           Source Port         |       Dest Port = VXLAN Port  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |           UDP Length          |        UDP Checksum           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   VXLAN Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |R|R|R|R|I|R|R|R|            Reserved                           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                VXLAN Network Identifier (VNI) |   Reserved    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Inner Ethernet Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             Inner Destination MAC Address                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Inner Destination MAC Address | Inner Source MAC Address      |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                Inner Source MAC Address                       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |OptnlEthtype = C-Tag 802.1Q    | Inner.VLAN Tag Information    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Payload:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Ethertype of Original Payload |                               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                               |
   |                                  Original Ethernet Payload    |
   |                                                               |
   |(Note that the original Ethernet Frame's FCS is not included)  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+





Mahalingam, et al.            Informational                    [Page 12]
^L
RFC 7348                          VXLAN                      August 2014


   Frame Check Sequence:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   New FCS (Frame Check Sequence) for Outer Ethernet Frame     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

            Figure 1: VXLAN Frame Format with IPv4 Outer Header

   The frame format above shows tunneling of Ethernet frames using IPv4
   for transport.  Use of VXLAN with IPv6 transport is detailed below.

    0                   1                   2                   3
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1

   Outer Ethernet Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             Outer Destination MAC Address                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Outer Destination MAC Address | Outer Source MAC Address      |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                Outer Source MAC Address                       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |OptnlEthtype = C-Tag 802.1Q    | Outer.VLAN Tag Information    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Ethertype = 0x86DD            |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Outer IPv6 Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |Version| Traffic Class |           Flow Label                  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Payload Length        | NxtHdr=17(UDP)|   Hop Limit   |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                                                               |
   +                                                               +
   |                                                               |
   +                     Outer Source IPv6 Address                 +
   |                                                               |
   +                                                               +
   |                                                               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                                                               |
   +                                                               +
   |                                                               |
   +                  Outer Destination IPv6 Address               +
   |                                                               |
   +                                                               +
   |                                                               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+



Mahalingam, et al.            Informational                    [Page 13]
^L
RFC 7348                          VXLAN                      August 2014


   Outer UDP Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |           Source Port         |       Dest Port = VXLAN Port  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |           UDP Length          |        UDP Checksum           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   VXLAN Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |R|R|R|R|I|R|R|R|            Reserved                           |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                VXLAN Network Identifier (VNI) |   Reserved    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Inner Ethernet Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |             Inner Destination MAC Address                     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Inner Destination MAC Address | Inner Source MAC Address      |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                Inner Source MAC Address                       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |OptnlEthtype = C-Tag 802.1Q    | Inner.VLAN Tag Information    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Payload:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   | Ethertype of Original Payload |                               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+                               |
   |                                  Original Ethernet Payload    |
   |                                                               |
   |(Note that the original Ethernet Frame's FCS is not included)  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Frame Check Sequence:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |   New FCS (Frame Check Sequence) for Outer Ethernet Frame     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

            Figure 2: VXLAN Frame Format with IPv6 Outer Header

6.  VXLAN Deployment Scenarios

   VXLAN is typically deployed in data centers on virtualized hosts,
   which may be spread across multiple racks.  The individual racks may
   be parts of a different Layer 3 network or they could be in a single
   Layer 2 network.  The VXLAN segments/overlay networks are overlaid on
   top of these Layer 2 or Layer 3 networks.



Mahalingam, et al.            Informational                    [Page 14]
^L
RFC 7348                          VXLAN                      August 2014


   Consider Figure 3, which depicts two virtualized servers attached to
   a Layer 3 infrastructure.  The servers could be on the same rack, on
   different racks, or potentially across data centers within the same
   administrative domain.  There are four VXLAN overlay networks
   identified by the VNIs 22, 34, 74, and 98.  Consider the case of
   VM1-1 in Server 1 and VM2-4 on Server 2, which are on the same VXLAN
   overlay network identified by VNI 22.  The VMs do not know about the
   overlay networks and transport method since the encapsulation and
   decapsulation happen transparently at the VTEPs on Servers 1 and 2.
   The other overlay networks and the corresponding VMs are VM1-2 on
   Server 1 and VM2-1 on Server 2, both on VNI 34; VM1-3 on Server 1 and
   VM2-2 on Server 2 on VNI 74; and finally VM1-4 on Server 1 and VM2-3
   on Server 2 on VNI 98.






































Mahalingam, et al.            Informational                    [Page 15]
^L
RFC 7348                          VXLAN                      August 2014


   +------------+-------------+
   |        Server 1          |
   | +----+----+  +----+----+ |
   | |VM1-1    |  |VM1-2    | |
   | |VNI 22   |  |VNI 34   | |
   | |         |  |         | |
   | +---------+  +---------+ |
   |                          |
   | +----+----+  +----+----+ |
   | |VM1-3    |  |VM1-4    | |
   | |VNI 74   |  |VNI 98   | |
   | |         |  |         | |
   | +---------+  +---------+ |
   | Hypervisor VTEP (IP1)    |
   +--------------------------+
                         |
                         |
                         |
                         |   +-------------+
                         |   |   Layer 3   |
                         |---|   Network   |
                             |             |
                             +-------------+
                                 |
                                 |
                                 +-----------+
                                             |
                                             |
                                      +------------+-------------+
                                      |        Server 2          |
                                      | +----+----+  +----+----+ |
                                      | |VM2-1    |  |VM2-2    | |
                                      | |VNI 34   |  |VNI 74   | |
                                      | |         |  |         | |
                                      | +---------+  +---------+ |
                                      |                          |
                                      | +----+----+  +----+----+ |
                                      | |VM2-3    |  |VM2-4    | |
                                      | |VNI 98   |  |VNI 22   | |
                                      | |         |  |         | |
                                      | +---------+  +---------+ |
                                      | Hypervisor VTEP (IP2)    |
                                      +--------------------------+

    Figure 3: VXLAN Deployment - VTEPs across a Layer 3 Network






Mahalingam, et al.            Informational                    [Page 16]
^L
RFC 7348                          VXLAN                      August 2014


   One deployment scenario is where the tunnel termination point is a
   physical server that understands VXLAN.  An alternate scenario is
   where nodes on a VXLAN overlay network need to communicate with nodes
   on legacy networks that could be VLAN based.  These nodes may be
   physical nodes or virtual machines.  To enable this communication, a
   network can include VXLAN gateways (see Figure 4 below with a switch
   acting as a VXLAN gateway) that forward traffic between VXLAN and
   non-VXLAN environments.

   Consider Figure 4 for the following discussion.  For incoming frames
   on the VXLAN connected interface, the gateway strips out the VXLAN
   header and forwards it to a physical port based on the destination
   MAC address of the inner Ethernet frame.  Decapsulated frames with
   the inner VLAN ID SHOULD be discarded unless configured explicitly to
   be passed on to the non-VXLAN interface.  In the reverse direction,
   incoming frames for the non-VXLAN interfaces are mapped to a specific
   VXLAN overlay network based on the VLAN ID in the frame.  Unless
   configured explicitly to be passed on in the encapsulated VXLAN
   frame, this VLAN ID is removed before the frame is encapsulated for
   VXLAN.

   These gateways that provide VXLAN tunnel termination functions could
   be ToR/access switches or switches higher up in the data center
   network topology -- e.g., core or even WAN edge devices.  The last
   case (WAN edge) could involve a Provider Edge (PE) router that
   terminates VXLAN tunnels in a hybrid cloud environment.  In all these
   instances, note that the gateway functionality could be implemented
   in software or hardware.























Mahalingam, et al.            Informational                    [Page 17]
^L
RFC 7348                          VXLAN                      August 2014


   +---+-----+---+                                    +---+-----+---+
   |    Server 1 |                                    |  Non-VXLAN  |
   (VXLAN enabled)<-----+                       +---->|  server     |
   +-------------+      |                       |     +-------------+
                        |                       |
   +---+-----+---+      |                       |     +---+-----+---+
   |Server 2     |      |                       |     |  Non-VXLAN  |
   (VXLAN enabled)<-----+   +---+-----+---+     +---->|    server   |
   +-------------+      |   |Switch acting|     |     +-------------+
                        |---|  as VXLAN   |-----|
   +---+-----+---+      |   |   Gateway   |
   | Server 3    |      |   +-------------+
   (VXLAN enabled)<-----+
   +-------------+      |
                        |
   +---+-----+---+      |
   | Server 4    |      |
   (VXLAN enabled)<-----+
   +-------------+

           Figure 4: VXLAN Deployment - VXLAN Gateway

6.1.  Inner VLAN Tag Handling

   Inner VLAN Tag Handling in VTEP and VXLAN gateway should conform to
   the following:

   Decapsulated VXLAN frames with the inner VLAN tag SHOULD be discarded
   unless configured otherwise.  On the encapsulation side, a VTEP
   SHOULD NOT include an inner VLAN tag on tunnel packets unless
   configured otherwise.  When a VLAN-tagged packet is a candidate for
   VXLAN tunneling, the encapsulating VTEP SHOULD strip the VLAN tag
   unless configured otherwise.

7.  Security Considerations

   Traditionally, Layer 2 networks can only be attacked from 'within' by
   rogue end points -- either by having inappropriate access to a LAN
   and snooping on traffic, by injecting spoofed packets to 'take over'
   another MAC address, or by flooding and causing denial of service.  A
   MAC-over-IP mechanism for delivering Layer 2 traffic significantly
   extends this attack surface.  This can happen by rogues injecting
   themselves into the network by subscribing to one or more multicast
   groups that carry broadcast traffic for VXLAN segments and also by
   sourcing MAC-over-UDP frames into the transport network to inject
   spurious traffic, possibly to hijack MAC addresses.





Mahalingam, et al.            Informational                    [Page 18]
^L
RFC 7348                          VXLAN                      August 2014


   This document does not incorporate specific measures against such
   attacks, relying instead on other traditional mechanisms layered on
   top of IP.  This section, instead, sketches out some possible
   approaches to security in the VXLAN environment.

   Traditional Layer 2 attacks by rogue end points can be mitigated by
   limiting the management and administrative scope of who deploys and
   manages VMs/gateways in a VXLAN environment.  In addition, such
   administrative measures may be augmented by schemes like 802.1X
   [802.1X] for admission control of individual end points.  Also, the
   use of the UDP-based encapsulation of VXLAN enables configuration and
   use of the 5-tuple-based ACL (Access Control List) functionality in
   physical switches.

   Tunneled traffic over the IP network can be secured with traditional
   security mechanisms like IPsec that authenticate and optionally
   encrypt VXLAN traffic.  This will, of course, need to be coupled with
   an authentication infrastructure for authorized end points to obtain
   and distribute credentials.

   VXLAN overlay networks are designated and operated over the existing
   LAN infrastructure.  To ensure that VXLAN end points and their VTEPs
   are authorized on the LAN, it is recommended that a VLAN be
   designated for VXLAN traffic and the servers/VTEPs send VXLAN traffic
   over this VLAN to provide a measure of security.

   In addition, VXLAN requires proper mapping of VNIs and VM membership
   in these overlay networks.  It is expected that this mapping be done
   and communicated to the management entity on the VTEP and the
   gateways using existing secure methods.

8.  IANA Considerations

   A well-known UDP port (4789) has been assigned by the IANA in the
   Service Name and Transport Protocol Port Number Registry for VXLAN.
   See Section 5 for discussion of the port number.

9.  References

9.1.  Normative References

   [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.








Mahalingam, et al.            Informational                    [Page 19]
^L
RFC 7348                          VXLAN                      August 2014


9.2.  Informative References

   [802.1aq] IEEE, "Standard for Local and metropolitan area networks --
             Media Access Control (MAC) Bridges and Virtual Bridged
             Local Area Networks -- Amendment 20: Shortest Path
             Bridging", IEEE P802.1aq-2012, 2012.

   [802.1D]  IEEE, "Draft Standard for Local and Metropolitan Area
             Networks/ Media Access Control (MAC) Bridges", IEEE
             P802.1D-2004, 2004.

   [802.1X]  IEEE, "IEEE Standard for Local and metropolitan area
             networks -- Port-Based Network Acces Control", IEEE Std
             802.1X-2010, February 2010.

   [RFC1191] Mogul, J. and S. Deering, "Path MTU discovery", RFC 1191,
             November 1990.

   [RFC1981] McCann, J., Deering, S., and J. Mogul, "Path MTU Discovery
             for IP version 6", RFC 1981, August 1996.

   [RFC4541] Christensen, M., Kimball, K., and F. Solensky,
             "Considerations for Internet Group Management Protocol
             (IGMP) and Multicast Listener Discovery (MLD) Snooping
             Switches", RFC 4541, May 2006.

   [RFC4601] Fenner, B., Handley, M., Holbrook, H., and I. Kouvelas,
             "Protocol Independent Multicast - Sparse Mode (PIM-SM):
             Protocol Specification (Revised)", RFC 4601, August 2006.

   [RFC5015] Handley, M., Kouvelas, I., Speakman, T., and L. Vicisano,
             "Bidirectional Protocol Independent Multicast (BIDIR-PIM)",
             RFC 5015, October 2007.

   [RFC6325] Perlman, R., Eastlake 3rd, D., Dutt, D., Gai, S., and A.
             Ghanwani, "Routing Bridges (RBridges): Base Protocol
             Specification", RFC 6325, July 2011.

   [RFC6335] Cotton, M., Eggert, L., Touch, J., Westerlund, M., and S.
             Cheshire, "Internet Assigned Numbers Authority (IANA)
             Procedures for the Management of the Service Name and
             Transport Protocol Port Number Registry", BCP 165, RFC
             6335, August 2011.








Mahalingam, et al.            Informational                    [Page 20]
^L
RFC 7348                          VXLAN                      August 2014


10.  Acknowledgments

   The authors wish to thank: Ajit Sanzgiri for contributions to the
   Security Considerations section and editorial inputs; Joseph Cheng,
   Margaret Petrus, Milin Desai, Nial de Barra, Jeff Mandin, and Siva
   Kollipara for their editorial reviews, inputs, and comments.

Authors' Addresses

   Mallik Mahalingam
   Storvisor, Inc.
   640 W. California Ave, Suite #110
   Sunnyvale, CA 94086.
   USA

   EMail: mallik_mahalingam@yahoo.com


   Dinesh G. Dutt
   Cumulus Networks
   140C S. Whisman Road
   Mountain View, CA 94041
   USA

   EMail: ddutt.ietf@hobbesdutt.com


   Kenneth Duda
   Arista Networks
   5453 Great America Parkway
   Santa Clara, CA 95054
   USA

   EMail: kduda@arista.com


   Puneet Agarwal
   Broadcom Corporation
   3151 Zanker Road
   San Jose, CA 95134
   USA

   EMail: pagarwal@broadcom.com








Mahalingam, et al.            Informational                    [Page 21]
^L
RFC 7348                          VXLAN                      August 2014


   Lawrence Kreeger
   Cisco Systems, Inc.
   170 W. Tasman Avenue
   San Jose, CA 95134
   USA

   EMail: kreeger@cisco.com


   T. Sridhar
   VMware, Inc.
   3401 Hillview
   Palo Alto, CA 94304
   USA

   EMail: tsridhar@vmware.com


   Mike Bursell
   Intel
   Bowyer's, North Road
   Great Yeldham
   Halstead
   Essex. C09 4QD
   UK

   EMail: mike.bursell@intel.com


   Chris Wright
   Red Hat, Inc.
   100 East Davie Street
   Raleigh, NC 27601
   USA

   EMail: chrisw@redhat.com















Mahalingam, et al.            Informational                    [Page 22]
^L