summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc8239.txt
blob: 7072467bd06cb767330ab8e578af0503a3e364a1 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
Internet Engineering Task Force (IETF)                        L. Avramov
Request for Comments: 8239                                        Google
Category: Informational                                          J. Rapp
ISSN: 2070-1721                                                   VMware
                                                             August 2017


                  Data Center Benchmarking Methodology

Abstract

   The purpose of this informational document is to establish test and
   evaluation methodology and measurement techniques for physical
   network equipment in the data center.  RFC 8238 is a prerequisite for
   this document, as it contains terminology that is considered
   normative.  Many of these terms and methods may be applicable beyond
   the scope of this document as the technologies originally applied in
   the data center are deployed elsewhere.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Not all documents
   approved by the IESG are a candidate for any level of Internet
   Standard; see Section 2 of RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc8239.

















Avramov & Rapp                Informational                     [Page 1]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


Copyright Notice

   Copyright (c) 2017 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1. Introduction ....................................................3
      1.1. Requirements Language ......................................4
      1.2. Methodology Format and Repeatability Recommendation ........4
   2. Line-Rate Testing ...............................................4
      2.1. Objective ..................................................4
      2.2. Methodology ................................................4
      2.3. Reporting Format ...........................................5
   3. Buffering Testing ...............................................6
      3.1. Objective ..................................................6
      3.2. Methodology ................................................7
      3.3. Reporting Format ...........................................9
   4. Microburst Testing .............................................10
      4.1. Objective .................................................10
      4.2. Methodology ...............................................10
      4.3. Reporting Format ..........................................11
   5. Head-of-Line Blocking ..........................................12
      5.1. Objective .................................................12
      5.2. Methodology ...............................................12
      5.3. Reporting Format ..........................................14
   6. Incast Stateful and Stateless Traffic ..........................15
      6.1. Objective .................................................15
      6.2. Methodology ...............................................15
      6.3. Reporting Format ..........................................17
   7. Security Considerations ........................................17
   8. IANA Considerations ............................................17
   9. References .....................................................18
      9.1. Normative References ......................................18
      9.2. Informative References ....................................18
   Acknowledgments ...................................................19
   Authors' Addresses ................................................19




Avramov & Rapp                Informational                     [Page 2]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


1.  Introduction

   Traffic patterns in the data center are not uniform and are
   constantly changing.  They are dictated by the nature and variety of
   applications utilized in the data center.  They can be largely
   east-west traffic flows (server to server inside the data center) in
   one data center and north-south (from the outside of the data center
   to the server) in another, while others may combine both.  Traffic
   patterns can be bursty in nature and contain many-to-one,
   many-to-many, or one-to-many flows.  Each flow may also be small and
   latency sensitive or large and throughput sensitive while containing
   a mix of UDP and TCP traffic.  All of these can coexist in a single
   cluster and flow through a single network device simultaneously.
   Benchmarking tests for network devices have long used [RFC1242],
   [RFC2432], [RFC2544], [RFC2889], and [RFC3918], which have largely
   been focused around various latency attributes and throughput
   [RFC2889] of the Device Under Test (DUT) being benchmarked.  These
   standards are good at measuring theoretical throughput, forwarding
   rates, and latency under testing conditions; however, they do not
   represent real traffic patterns that may affect these networking
   devices.

   Currently, typical data center networking devices are
   characterized by:

   -  High port density (48 ports or more).

   -  High speed (currently, up to 100 GB/s per port).

   -  High throughput (line rate on all ports for Layer 2 and/or
      Layer 3).

   -  Low latency (in the microsecond or nanosecond range).

   -  Low amount of buffer (in the MB range per networking device).

   -  Layer 2 and Layer 3 forwarding capability (Layer 3 not mandatory).

   This document provides a methodology for benchmarking data center
   physical network equipment DUTs, including congestion scenarios,
   switch buffer analysis, microburst, and head-of-line blocking, while
   also using a wide mix of traffic conditions.  [RFC8238] is a
   prerequisite for this document, as it contains terminology that is
   considered normative.







Avramov & Rapp                Informational                     [Page 3]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


1.1.  Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in
   BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

1.2.  Methodology Format and Repeatability Recommendation

   The following format is used in Sections 2 through 6 of this
   document:

   -  Objective

   -  Methodology

   -  Reporting Format

   For each test methodology described in this document, it is critical
   that repeatability of the results be obtained.  The recommendation is
   to perform enough iterations of the given test and to make sure that
   the result is consistent.  This is especially important in the
   context of the tests described in Section 3, as the buffering testing
   has historically been the least reliable.  The number of iterations
   SHOULD be explicitly reported.  The relative standard deviation
   SHOULD be below 10%.

2.  Line-Rate Testing

2.1.  Objective

   The objective of this test is to provide a "maximum rate" test for
   the performance values for throughput, latency, and jitter.  It is
   meant to provide (1) the tests to perform and (2) methodology for
   verifying that a DUT is capable of forwarding packets at line rate
   under non-congested conditions.

2.2.  Methodology

   A traffic generator SHOULD be connected to all ports on the DUT.  Two
   tests MUST be conducted: (1) a port-pair test [RFC2544] [RFC3918] and
   (2) a test using a full-mesh DUT [RFC2889] [RFC3918].

   For all tests, the traffic generator's sending rate MUST be less than
   or equal to 99.98% of the nominal value of the line rate (with no
   further Parts Per Million (PPM) adjustment to account for interface
   clock tolerances), to ensure stressing of the DUT in reasonable



Avramov & Rapp                Informational                     [Page 4]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   worst-case conditions (see [RFC8238], Section 5 for more details).
   Test results at a lower rate MAY be provided for better understanding
   of performance increase in terms of latency and jitter when the rate
   is lower than 99.98%.  The receiving rate of the traffic SHOULD be
   captured during this test as a percentage of line rate.

   The test MUST provide the statistics of minimum, average, and
   maximum of the latency distribution, for the exact same iteration of
   the test.

   The test MUST provide the statistics of minimum, average, and maximum
   of the jitter distribution, for the exact same iteration of the test.

   Alternatively, when a traffic generator cannot be connected to all
   ports on the DUT, a snake test MUST be used for line-rate testing,
   excluding latency and jitter, as those would become irrelevant.  The
   snake test is performed as follows:

   -  Connect the first and last port of the DUT to a traffic generator.

   -  Connect, back to back and sequentially, all the ports in between:
      port 2 to port 3, port 4 to port 5, etc., to port N-2 to port N-1,
      where N is the total number of ports of the DUT.

   -  Configure port 1 and port 2 in the same VLAN X, port 3 and port 4
      in the same VLAN Y, etc., and port N-1 and port N in the same
      VLAN Z.

   This snake test provides the capability to test line rate for Layer 2
   and Layer 3 [RFC2544] [RFC3918] in instances where a traffic
   generator with only two ports is available.  Latency and jitter are
   not to be considered for this test.

2.3.  Reporting Format

   The report MUST include the following:

   -  Physical-layer calibration information, as defined in [RFC8238],
      Section 4.

   -  Number of ports used.

   -  Reading for "throughput received as a percentage of bandwidth",
      while sending 99.98% of the nominal value of the line rate on each
      port, for each packet size from 64 bytes to 9216 bytes.  As
      guidance, with a packet-size increment of 64 bytes between each
      iteration being ideal, 256-byte and 512-byte packets are also




Avramov & Rapp                Informational                     [Page 5]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


      often used.  The most common packet-size ordering for the report
      is 64 bytes, 128 bytes, 256 bytes, 512 bytes, 1024 bytes,
      1518 bytes, 4096 bytes, 8000 bytes, and 9216 bytes.

      The pattern for testing can be expressed using [RFC6985].

   -  Throughput needs to be expressed as a percentage of total
      transmitted frames.

   -  Packet drops MUST be expressed as a count of packets and SHOULD be
      expressed as a percentage of line rate.

   -  For latency and jitter, values are expressed in units of time
      (usually microseconds or nanoseconds), reading across packet sizes
      from 64 bytes to 9216 bytes.

   -  For latency and jitter, provide minimum, average, and maximum
      values.  If different iterations are done to gather the minimum,
      average, and maximum values, this SHOULD be specified in the
      report, along with a justification for why the information could
      not have been gathered in the same test iteration.

   -  For jitter, a histogram describing the population of packets
      measured per latency or latency buckets is RECOMMENDED.

   -  The tests for throughput, latency, and jitter MAY be conducted as
      individual independent trials, with proper documentation provided
      in the report, but SHOULD be conducted at the same time.

   -  The methodology assumes that the DUT has at least nine ports, as
      certain methodologies require nine or more ports.

3.  Buffering Testing

3.1.  Objective

   The objective of this test is to measure the size of the buffer of a
   DUT under typical/many/multiple conditions.  Buffer architectures
   between multiple DUTs can differ and include egress buffering, shared
   egress buffering SoC (Switch-on-Chip), ingress buffering, or a
   combination thereof.  The test methodology covers the buffer
   measurement, regardless of buffer architecture used in the DUT.









Avramov & Rapp                Informational                     [Page 6]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


3.2.  Methodology

   A traffic generator MUST be connected to all ports on the DUT.  The
   methodology for measuring buffering for a data center switch is based
   on using known congestion of known fixed packet size, along with
   maximum latency value measurements.  The maximum latency will
   increase until the first packet drop occurs.  At this point, the
   maximum latency value will remain constant.  This is the point of
   inflection of this maximum latency change to a constant value.  There
   MUST be multiple ingress ports receiving a known amount of frames at
   a known fixed size, destined for the same egress port in order to
   create a known congestion condition.  The total amount of packets
   sent from the oversubscribed port minus one, multiplied by the packet
   size, represents the maximum port buffer size at the measured
   inflection point.

   Note that the tests described in procedures 1), 2), 3), and 4) in
   this section have iterations called "first iteration", "second
   iteration", and "last iteration".  The idea is to show the first
   two iterations so the reader understands the logic of how to keep
   incrementing the iterations.  The last iteration shows the end state
   of the variables.

   1) Measure the highest buffer efficiency.

      o  First iteration: Ingress port 1 sending 64-byte packets at line
         rate to egress port 2, while port 3 is sending a known low
         amount of oversubscription traffic (1% recommended) with the
         same packet size of 64 bytes to egress port 2.  Measure the
         buffer size value of the number of frames sent from the port
         sending the oversubscribed traffic up to the inflection point
         multiplied by the frame size.

      o  Second iteration: Ingress port 1 sending 65-byte packets at
         line rate to egress port 2, while port 3 is sending a known low
         amount of oversubscription traffic (1% recommended) with the
         same packet size of 65 bytes to egress port 2.  Measure the
         buffer size value of the number of frames sent from the port
         sending the oversubscribed traffic up to the inflection point
         multiplied by the frame size.

      o  Last iteration: Ingress port 1 sending packets of size B bytes
         at line rate to egress port 2, while port 3 is sending a known
         low amount of oversubscription traffic (1% recommended) with
         the same packet size of B bytes to egress port 2.  Measure the
         buffer size value of the number of frames sent from the port
         sending the oversubscribed traffic up to the inflection point
         multiplied by the frame size.



Avramov & Rapp                Informational                     [Page 7]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


      When the B value is found to provide the largest buffer size, then
      size B allows the highest buffer efficiency.

   2) Measure maximum port buffer size.

      At fixed packet size B as determined in procedure 1), for a fixed
      default Differentiated Services Code Point (DSCP) / Class of
      Service (CoS) value of 0 and for unicast traffic, proceed with the
      following:

      o  First iteration: Ingress port 1 sending line rate to egress
         port 2, while port 3 is sending a known low amount of
         oversubscription traffic (1% recommended) with the same packet
         size to egress port 2.  Measure the buffer size value by
         multiplying the number of extra frames sent by the frame size.

      o  Second iteration: Ingress port 2 sending line rate to egress
         port 3, while port 4 is sending a known low amount of
         oversubscription traffic (1% recommended) with the same packet
         size to egress port 3.  Measure the buffer size value by
         multiplying the number of extra frames sent by the frame size.

      o  Last iteration: Ingress port N-2 sending line rate to egress
         port N-1, while port N is sending a known low amount of
         oversubscription traffic (1% recommended) with the same packet
         size to egress port N.  Measure the buffer size value by
         multiplying the number of extra frames sent by the frame size.

      This test series MAY be repeated using all different DSCP/CoS
      values of traffic, and then using multicast traffic, in order to
      find out if there is any DSCP/CoS impact on the buffer size.

   3) Measure maximum port pair buffer sizes.

      o  First iteration: Ingress port 1 sending line rate to egress
         port 2, ingress port 3 sending line rate to egress port 4, etc.
         Ingress port N-1 and port N will oversubscribe, at 1% of line
         rate, egress port 2 and port 3, respectively.  Measure the
         buffer size value by multiplying the number of extra frames
         sent by the frame size for each egress port.

      o  Second iteration: Ingress port 1 sending line rate to egress
         port 2, ingress port 3 sending line rate to egress port 4, etc.
         Ingress port N-1 and port N will oversubscribe, at 1% of line
         rate, egress port 4 and port 5, respectively.  Measure the
         buffer size value by multiplying the number of extra frames
         sent by the frame size for each egress port.




Avramov & Rapp                Informational                     [Page 8]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


      o  Last iteration: Ingress port 1 sending line rate to egress
         port 2, ingress port 3 sending line rate to egress port 4, etc.
         Ingress port N-1 and port N will oversubscribe, at 1% of line
         rate, egress port N-3 and port N-2, respectively.  Measure the
         buffer size value by multiplying the number of extra frames
         sent by the frame size for each egress port.

      This test series MAY be repeated using all different DSCP/CoS
      values of traffic and then using multicast traffic.

   4) Measure maximum DUT buffer size with many-to-one ports.

      o  First iteration: Ingress ports 1,2,... N-1 each sending
         [(1/[N-1])*99.98]+[1/[N-1]] % of line rate per port to egress
         port N.

      o  Second iteration: Ingress ports 2,... N each sending
         [(1/[N-1])*99.98]+[1/[N-1]] % of line rate per port to egress
         port 1.

      o  Last iteration: Ingress ports N,1,2...N-2 each sending
         [(1/[N-1])*99.98]+[1/[N-1]] % of line rate per port to egress
         port N-1.

   This test series MAY be repeated using all different CoS values of
   traffic and then using multicast traffic.

   Unicast traffic, and then multicast traffic, SHOULD be used in order
   to determine the proportion of buffer for the documented selection of
   tests.  Also, the CoS value for the packets SHOULD be provided for
   each test iteration, as the buffer allocation size MAY differ per CoS
   value.  It is RECOMMENDED that the ingress and egress ports be varied
   in a random but documented fashion in multiple tests in order to
   measure the buffer size for each port of the DUT.

3.3.  Reporting Format

   The report MUST include the following:

   -  The packet size used for the most efficient buffer used,
      along with the DSCP/CoS value.

   -  The maximum port buffer size for each port.

   -  The maximum DUT buffer size.

   -  The packet size used in the test.




Avramov & Rapp                Informational                     [Page 9]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   -  The amount of oversubscription, if different than 1%.

   -  The number of ingress and egress ports, along with their location
      on the DUT.

   -  The repeatability of the test needs to be indicated: the number of
      iterations of the same test and the percentage of variation
      between results for each of the tests (min, max, avg).

   The percentage of variation is a metric providing a sense of how big
   the difference is between the measured value and the previous values.

   For example, for a latency test where the minimum latency is
   measured, the percentage of variation (PV) of the minimum latency
   will indicate by how much this value has varied between the current
   test executed and the previous one.

   PV = ((x2-x1)/x1)*100, where x2 is the minimum latency value in the
   current test and x1 is the minimum latency value obtained in the
   previous test.

   The same formula is used for maximum and average variations measured.

4.  Microburst Testing

4.1.  Objective

   The objective of this test is to find the maximum amount of packet
   bursts that a DUT can sustain under various configurations.

   This test provides additional methodology that supplements the tests
   described in [RFC1242], [RFC2432], [RFC2544], [RFC2889], and
   [RFC3918].

   -  All bursts should be sent with 100% intensity.  Note: "Intensity"
      is defined in [RFC8238], Section 6.1.1.

   -  All ports of the DUT must be used for this test.

   -  It is recommended that all ports be tested simultaneously.

4.2.  Methodology

   A traffic generator MUST be connected to all ports on the DUT.  In
   order to cause congestion, two or more ingress ports MUST send bursts
   of packets destined for the same egress port.  The simplest of the
   setups would be two ingress ports and one egress port (2 to 1).




Avramov & Rapp                Informational                    [Page 10]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   The burst MUST be sent with an intensity (as defined in [RFC8238],
   Section 6.1.1) of 100%, meaning that the burst of packets will be
   sent with a minimum interpacket gap.  The amount of packets contained
   in the burst will be trial variable and increase until there is a
   non-zero packet loss measured.  The aggregate amount of packets from
   all the senders will be used to calculate the maximum microburst
   amount that the DUT can sustain.

   It is RECOMMENDED that the ingress and egress ports be varied in
   multiple tests in order to measure the maximum microburst capacity.

   The intensity of a microburst (see [RFC8238], Section 6.1.1) MAY be
   varied in order to obtain the microburst capacity at various
   ingress rates.

   It is RECOMMENDED that all ports on the DUT be tested simultaneously,
   and in various configurations, in order to understand all the
   combinations of ingress ports, egress ports, and intensities.

   An example would be:

   o  First iteration: N-1 ingress ports sending to one egress port.

   o  Second iteration: N-2 ingress ports sending to two egress ports.

   o  Last iteration: Two ingress ports sending to N-2 egress ports.

4.3.  Reporting Format

   The report MUST include the following:

   -  The maximum number of packets received per ingress port with the
      maximum burst size obtained with zero packet loss.

   -  The packet size used in the test.

   -  The number of ingress and egress ports, along with their location
      on the DUT.

   -  The repeatability of the test needs to be indicated: the number of
      iterations of the same test and the percentage of variation
      between results (min, max, avg).









Avramov & Rapp                Informational                    [Page 11]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


5.  Head-of-Line Blocking

5.1.  Objective

   Head-of-line blocking (HOLB) is a performance-limiting phenomenon
   that occurs when packets are held up by the first packet ahead
   waiting to be transmitted to a different output port.  This is
   defined in RFC 2889, Section 5.5 ("Congestion Control").  This
   section expands on RFC 2889 in the context of data center
   benchmarking.

   The objective of this test is to understand the DUT's behavior in the
   HOLB scenario and measure the packet loss.

   The differences between this HOLB test and RFC 2889 are as follows:

   -  This HOLB test starts with eight ports in two groups of four ports
      each, instead of four ports (as compared with Section 5.5 of
      RFC 2889).

   -  This HOLB test shifts all the port numbers by one in a second
      iteration of the test; this is new, as compared to the HOLB test
      described in RFC 2889.  The shifting port numbers continue until
      all ports are the first in the group; the purpose of this is to
      make sure that all permutations are tested in order to cover
      differences in behavior in the SoC of the DUT.

   -  Another test within this HOLB test expands the group of ports,
      such that traffic is divided among four ports instead of two
      (25% instead of 50% per port).

   -  Section 5.3 lists requirements that supplement the requirements
      listed in RFC 2889, Section 5.5.

5.2.  Methodology

   In order to cause congestion in the form of HOLB, groups of
   four ports are used.  A group has two ingress ports and two
   egress ports.  The first ingress port MUST have two flows configured,
   each going to a different egress port.  The second ingress port will
   congest the second egress port by sending line rate.  The goal is to
   measure if there is loss on the flow for the first egress port, which
   is not oversubscribed.

   A traffic generator MUST be connected to at least eight ports on the
   DUT and SHOULD be connected using all the DUT ports.





Avramov & Rapp                Informational                    [Page 12]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   Note that the tests described in procedures 1) and 2) in this section
   have iterations called "first iteration", "second iteration", and
   "last iteration".  The idea is to show the first two iterations so
   the reader understands the logic of how to keep incrementing the
   iterations.  The last iteration shows the end state of the variables.

   1) Measure two groups with eight DUT ports.

      o  First iteration: Measure the packet loss for two groups with
         consecutive ports.

         The composition of the first group is as follows:

         Ingress port 1 sending 50% of traffic to egress port 3
         and ingress port 1 sending 50% of traffic to egress port 4.
         Ingress port 2 sending line rate to egress port 4.
         Measure the amount of traffic loss for the traffic from ingress
         port 1 to egress port 3.

         The composition of the second group is as follows:

         Ingress port 5 sending 50% of traffic to egress port 7
         and ingress port 5 sending 50% of traffic to egress port 8.
         Ingress port 6 sending line rate to egress port 8.
         Measure the amount of traffic loss for the traffic from ingress
         port 5 to egress port 7.

      o  Second iteration: Repeat the first iteration by shifting all
         the ports from N to N+1.

         The composition of the first group is as follows:

         Ingress port 2 sending 50% of traffic to egress port 4
         and ingress port 2 sending 50% of traffic to egress port 5.
         Ingress port 3 sending line rate to egress port 5.
         Measure the amount of traffic loss for the traffic from ingress
         port 2 to egress port 4.

         The composition of the second group is as follows:

         Ingress port 6 sending 50% of traffic to egress port 8
         and ingress port 6 sending 50% of traffic to egress port 9.
         Ingress port 7 sending line rate to egress port 9.
         Measure the amount of traffic loss for the traffic from ingress
         port 6 to egress port 8.






Avramov & Rapp                Informational                    [Page 13]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


      o  Last iteration: When the first port of the first group is
         connected to the last DUT port and the last port of the second
         group is connected to the seventh port of the DUT.

      Measure the amount of traffic loss for the traffic from ingress
      port N to egress port 2 and from ingress port 4 to egress port 6.

   2) Measure with N/4 groups with N DUT ports.

      The traffic from the ingress port is split across four egress
      ports (100/4 = 25%).

      o  First iteration: Expand to fully utilize all the DUT ports in
         increments of four.  Repeat the methodology of procedure 1)
         with all the groups of ports possible to achieve on the device,
         and measure the amount of traffic loss for each port group.

      o  Second iteration: Shift by +1 the start of each consecutive
         port of the port groups.

      o  Last iteration: Shift by N-1 the start of each consecutive port
         of the port groups, and measure the amount of traffic loss for
         each port group.

5.3.  Reporting Format

   For each test, the report MUST include the following:

   -  The port configuration, including the number and location of
      ingress and egress ports located on the DUT.

   -  If HOLB was observed in accordance with the HOLB test described in
      Section 5.

   -  Percent of traffic loss.

   -  The repeatability of the test needs to be indicated: the number of
      iterations of the same test and the percentage of variation
      between results (min, max, avg).












Avramov & Rapp                Informational                    [Page 14]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


6.  Incast Stateful and Stateless Traffic

6.1.  Objective

   The objective of this test is to measure the values for TCP Goodput
   [TCP-INCAST] and latency with a mix of large and small flows.  The
   test is designed to simulate a mixed environment of stateful flows
   that require high rates of goodput and stateless flows that require
   low latency.  Stateful flows are created by generating TCP traffic,
   and stateless flows are created using UDP traffic.

6.2.  Methodology

   In order to simulate the effects of stateless and stateful traffic on
   the DUT, there MUST be multiple ingress ports receiving traffic
   destined for the same egress port.  There also MAY be a mix of
   stateful and stateless traffic arriving on a single ingress port.
   The simplest setup would be two ingress ports receiving traffic
   destined to the same egress port.

   One ingress port MUST maintain a TCP connection through the ingress
   port to a receiver connected to an egress port.  Traffic in the TCP
   stream MUST be sent at the maximum rate allowed by the traffic
   generator.  At the same time, the TCP traffic is flowing through the
   DUT, and the stateless traffic is sent destined to a receiver on the
   same egress port.  The stateless traffic MUST be a microburst of
   100% intensity.

   It is RECOMMENDED that the ingress and egress ports be varied in
   multiple tests in order to measure the maximum microburst capacity.

   The intensity of a microburst MAY be varied in order to obtain the
   microburst capacity at various ingress rates.

   It is RECOMMENDED that all ports on the DUT be used in the test.

   The tests described below have iterations called "first iteration",
   "second iteration", and "last iteration".  The idea is to show the
   first two iterations so the reader understands the logic of how to
   keep incrementing the iterations.  The last iteration shows the
   end state of the variables.










Avramov & Rapp                Informational                    [Page 15]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   For example:

   Stateful traffic port variation (TCP traffic):

   TCP traffic needs to be generated for this test.  During the
   iterations, the number of egress ports MAY vary as well.

   o  First iteration: One ingress port receiving stateful TCP traffic
      and one ingress port receiving stateless traffic destined to
      one egress port.

   o  Second iteration: Two ingress ports receiving stateful TCP traffic
      and one ingress port receiving stateless traffic destined to
      one egress port.

   o  Last iteration: N-2 ingress ports receiving stateful TCP traffic
      and one ingress port receiving stateless traffic destined to
      one egress port.

   Stateless traffic port variation (UDP traffic):

   UDP traffic needs to be generated for this test.  During the
   iterations, the number of egress ports MAY vary as well.

   o  First iteration: One ingress port receiving stateful TCP traffic
      and one ingress port receiving stateless traffic destined to
      one egress port.

   o  Second iteration: One ingress port receiving stateful TCP traffic
      and two ingress ports receiving stateless traffic destined to
      one egress port.

   o  Last iteration: One ingress port receiving stateful TCP traffic
      and N-2 ingress ports receiving stateless traffic destined to
      one egress port.
















Avramov & Rapp                Informational                    [Page 16]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


6.3.  Reporting Format

   The report MUST include the following:

   -  Number of ingress and egress ports, along with designation of
      stateful or stateless flow assignment.

   -  Stateful flow goodput.

   -  Stateless flow latency.

   -  The repeatability of the test needs to be indicated: the number of
      iterations of the same test and the percentage of variation
      between results (min, max, avg).

7.  Security Considerations

   Benchmarking activities as described in this memo are limited to
   technology characterization using controlled stimuli in a laboratory
   environment, with dedicated address space and the constraints
   specified in the sections above.

   The benchmarking network topology will be an independent test setup
   and MUST NOT be connected to devices that may forward the test
   traffic into a production network or misroute traffic to the test
   management network.

   Further, benchmarking is performed on a "black-box" basis, relying
   solely on measurements observable external to the DUT.

   Special capabilities SHOULD NOT exist in the DUT specifically for
   benchmarking purposes.  Any implications for network security arising
   from the DUT SHOULD be identical in the lab and in production
   networks.

8.  IANA Considerations

   This document does not require any IANA actions.













Avramov & Rapp                Informational                    [Page 17]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


9.  References

9.1.  Normative References

   [RFC1242]  Bradner, S., "Benchmarking Terminology for Network
              Interconnection Devices", RFC 1242, DOI 10.17487/RFC1242,
              July 1991, <https://www.rfc-editor.org/info/rfc1242>.

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC2544]  Bradner, S. and J. McQuaid, "Benchmarking Methodology for
              Network Interconnect Devices", RFC 2544,
              DOI 10.17487/RFC2544, March 1999,
              <https://www.rfc-editor.org/info/rfc2544>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in
              RFC 2119 Key Words", BCP 14, RFC 8174,
              DOI 10.17487/RFC8174, May 2017,
              <https://www.rfc-editor.org/info/rfc8174>.

   [RFC8238]  Avramov, L. and J. Rapp, "Data Center Benchmarking
              Terminology", RFC 8238, DOI 10.17487/RFC8238, August 2017,
              <https://www.rfc-editor.org/info/rfc8238>.

9.2.  Informative References

   [RFC2432]  Dubray, K., "Terminology for IP Multicast Benchmarking",
              RFC 2432, DOI 10.17487/RFC2432, October 1998,
              <https://www.rfc-editor.org/info/rfc2432>.

   [RFC2889]  Mandeville, R. and J. Perser, "Benchmarking Methodology
              for LAN Switching Devices", RFC 2889,
              DOI 10.17487/RFC2889, August 2000,
              <https://www.rfc-editor.org/info/rfc2889>.

   [RFC3918]  Stopp, D. and B. Hickman, "Methodology for IP Multicast
              Benchmarking", RFC 3918, DOI 10.17487/RFC3918,
              October 2004, <https://www.rfc-editor.org/info/rfc3918>.










Avramov & Rapp                Informational                    [Page 18]
^L
RFC 8239          Data Center Benchmarking Methodology       August 2017


   [RFC6985]  Morton, A., "IMIX Genome: Specification of Variable Packet
              Sizes for Additional Testing", RFC 6985,
              DOI 10.17487/RFC6985, July 2013,
              <https://www.rfc-editor.org/info/rfc6985>.

   [TCP-INCAST]
              Chen, Y., Griffith, R., Zats, D., Joseph, A., and R. Katz,
              "Understanding TCP Incast and Its Implications for Big
              Data Workloads", April 2012, <http://yanpeichen.com/
              professional/usenixLoginIncastReady.pdf>.

Acknowledgments

   The authors would like to thank Al Morton and Scott Bradner for their
   reviews and feedback.

Authors' Addresses

   Lucien Avramov
   Google
   1600 Amphitheatre Parkway
   Mountain View, CA  94043
   United States of America

   Email: lucien.avramov@gmail.com


   Jacob Rapp
   VMware
   3401 Hillview Ave.
   Palo Alto, CA  94304
   United States of America

   Email: jhrapp@gmail.com

















Avramov & Rapp                Informational                    [Page 19]
^L