summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc9271.txt
blob: 0090725e8be1c090f1451cf1d9e9b15fbb2dc124 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
Independent Submission                                     R. Price, Ed.
Request for Comments: 9271                     Network UPS Tools Project
Category: Informational                                      August 2022
ISSN: 2070-1721


 Uninterruptible Power Supply (UPS) Management Protocol -- Commands and
                               Responses

Abstract

   This document describes the command/response protocol currently used
   in the management of Uninterruptible Power Supply (UPS) units and
   other power devices often deployed in small offices and in IT
   installations subject to an erratic public power supply.  The UPS
   units typically interface to an Attachment Daemon in the system they
   protect.  This daemon is in turn polled by a Management Daemon that
   notifies users and system administrators of power supply incidents
   and automates system shutdown decisions.  The commands and responses
   described by this document are exchanged between the UPS Attachment
   Daemon and the Management Daemon.  The practice current when this
   protocol was first developed risks weak security, and this is
   addressed in the Security Considerations sections of this document.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This is a contribution to the RFC Series, independently of any other
   RFC stream.  The RFC Editor has chosen to publish this document at
   its discretion and makes no statement about its value for
   implementation or deployment.  Documents approved for publication by
   the RFC Editor are not candidates for any level of Internet Standard;
   see Section 2 of RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   https://www.rfc-editor.org/info/rfc9271.

Copyright Notice

   Copyright (c) 2022 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (https://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.

Table of Contents

   1.  Introduction
     1.1.  Current Practice
       1.1.1.  NUT Project
       1.1.2.  The Shutdown Story
       1.1.3.  How to Read this Document
     1.2.  Additional Information
     1.3.  Requirements Language
   2.  Terminology
     2.1.  Administrative User
     2.2.  Attachment Daemon
     2.3.  Driver
     2.4.  Event
     2.5.  Instant Command
     2.6.  Management Daemon
     2.7.  Primary
     2.8.  Secondary
     2.9.  Session
     2.10. UPS Status
     2.11. UPS Variable
   3.  Protocol Overview
   4.  Protocol Specification
     4.1.  Notation Used in this Specification
     4.2.  Commands
       4.2.1.  ATTACH
       4.2.2.  DETACH
       4.2.3.  FSD
       4.2.4.  GET
         4.2.4.1.  GET CMDDESC
         4.2.4.2.  GET DESC
         4.2.4.3.  GET NUMATTACH
         4.2.4.4.  GET TYPE
         4.2.4.5.  GET UPSDESC
         4.2.4.6.  GET VAR
       4.2.5.  HELP
       4.2.6.  INSTCMD
       4.2.7.  LIST
         4.2.7.1.  LIST CLIENT
         4.2.7.2.  LIST CMD
         4.2.7.3.  LIST ENUM
         4.2.7.4.  LIST RANGE
         4.2.7.5.  LIST RW
         4.2.7.6.  LIST UPS
         4.2.7.7.  LIST VAR
       4.2.8.  PASSWORD
       4.2.9.  PRIMARY
       4.2.10. PROTVER
       4.2.11. SET
       4.2.12. STARTTLS
         4.2.12.1.  Key Infrastructure and Self-Signed Certificates
       4.2.13. USERNAME
       4.2.14. VER
     4.3.  Summary of Responses
       4.3.1.  Response When Command Succeeds
       4.3.2.  Error Responses
     4.4.  An ABNF of the Commands
       4.4.1.  Responses to Commands
   5.  Statuses and Events
     5.1.  Status Symbols
     5.2.  Events
   6.  Security Considerations
     6.1.  Current General Security Practice
     6.2.  Communication Security Requirements
       6.2.1.  Certificate Security
     6.3.  Attacks and Defenses
       6.3.1.  Eavesdropping
         6.3.1.1.  Misplaced Declarations Requiring TLS
         6.3.1.2.  Weak Protection in Previous Version 2.7.4
       6.3.2.  Man-in-the-Middle
       6.3.3.  Masquerade Attack: Agent Verification
       6.3.4.  Message Insertion, Deletion, and Modification
       6.3.5.  Replay
       6.3.6.  Denial of Service
   7.  IANA Considerations
   8.  Implementation Status
     8.1.  Inclusion in Software Distributions
     8.2.  Recommended Minimum Support
       8.2.1.  Desktop PC Variables
       8.2.2.  Unattended Servers and Additional Variables
       8.2.3.  Commands and Other Technical Terms
       8.2.4.  Support for Earlier Versions
   9.  References
     9.1.  Normative References
     9.2.  Informative References
   Appendix A.  Variables
     A.1.  Typical UPS Variables
     A.2.  Typical UPS Readable and Writable Variables
     A.3.  Typical UPS Instant Commands
   Appendix B.  The Shutdown Story for System and UPS
   Appendix C.  Technical Terms: Historical Differences
   Appendix D.  Security Defenses in Release 2.7.4
     D.1.  Shims
       D.1.1.  Attachment Daemon Shim
       D.1.2.  Management Daemon Shim
     D.2.  TLS Tunnels
     D.3.  VPN
     D.4.  VLAN
   Appendix E.  Administrative Security
     E.1.  Management of Administrative Users
     E.2.  An Administrative User of a Client Management Daemon
       E.2.1.  An Administrative User Logs into a Short Session
       E.2.2.  An Administrative User Logs into a Long Session
   Acknowledgments
   Author's Address

1.  Introduction

1.1.  Current Practice

   This document describes UPS management techniques and current UPS
   management practice published by the Network UPS Tools (NUT) Project.
   The document is based on version 2.8.0 of the NUT Project software,
   which supports version 1.3 of the NUT protocol.

   Since May 2002, the protocol described by this document has been
   operating on IANA port 3493/TCP (nut).

1.1.1.  NUT Project

   The primary goal of the Network UPS Tools (NUT) Project software
   [NUT] is to provide support for power devices, such as UPSs.  The
   project has been in operation since 1998, with a major rework in
   2003.  It operates through a user mailing list [nut-upsuser], a
   developer mailing list [nut-upsdev], a website [NUT], and a GitHub
   repository [nut-repository].  See [githist] and Appendix J of
   [History] for a history of the project.

1.1.2.  The Shutdown Story

   The Shutdown Story section (see Appendix B) describes the current UPS
   management practice for performing a managed shutdown of unattended
   infrastructure after an unscheduled failure of the public power
   supply in order to minimize the risk of corruption to data processed
   by this infrastructure.

1.1.3.  How to Read this Document

   As a simplification to ease reading, the term "UPS" is used when
   "Managed Power Device" would be more complete.  The reader should
   understand the simple "UPS" to include other managed power devices.

   The statuses and events appearing in this document are named with
   short text-form names, some of which are abbreviations.  A full list
   of the statuses can be found in Section 5.1, while the events are
   listed in Section 5.2.

   This document refers to the "public power supply".  Other texts
   frequently refer to "utility power", "input source power", or even
   "wall power".

1.2.  Additional Information

   Additional information about the NUT Project is available in the
   project documentation [Documentation].  Requests for further
   information about this protocol and related technical matters may be
   addressed to the mailing list [nut-upsuser] of the NUT Project.

1.3.  Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in
   BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

2.  Terminology

   The following technical terms appear in this document.  They are
   listed in alphabetical order.

2.1.  Administrative User

   In current practice, the commands and other functions offered by the
   Attachment Daemon are made available to a set of users known as
   Management Daemons.  These Management Daemons authenticate to the
   Attachment Daemon with basic credentials (username and password).
   Although called "users", the administrative users are not system
   users; they are specific to an Attachment Daemon and are listed in a
   text file (currently upsd.users) that is read by the Attachment
   Daemon and that assigns to each of them the password, Instant
   Commands, and actions that are allowed, together with the Primary or
   Secondary status of the Management Daemon.  For details, see
   Appendix E.1.  For details of the Primary, see Section 2.7; for
   details of the Secondary, see Section 2.8.  Typically, a high-level
   user will be able to send command FSD, but a low-level user might
   only be allowed to access the test panel.  The security provisions
   for administrative users are discussed in Appendix E.

2.2.  Attachment Daemon

   The Attachment Daemon retrieves the status from the UPS and sends
   commands to it often through a Driver specific to the hardware model
   and the connection medium, e.g., USB, serial.  See Section 2.3.  It
   maintains an abstracted view of the hardware through the use of
   hardware statuses.  See Section 2.10.  A Management Daemon may
   consult the abstracted view using the commands described in this
   document.

   See Section 8.2 for details of the recommended minimum support of
   variables, which calls for Attachment Daemon support of statuses OB,
   OL, LB, and FSD.

   The NUT Project has implemented an Attachment Daemon as program upsd
   and a set of hardware-specific Drivers, all written in K&R C
   [C2ndEd].  The Attachment Daemon is launched as system user "root"
   but for better security; then, it drops the privilege to run as a
   detached software service.

2.3.  Driver

   A Driver is that part of an Attachment Daemon that is specific to the
   UPS hardware, the connection medium, and the connection protocol,
   e.g., USB, serial.  In current practice, the Attachment Daemon has a
   Driver for each hardware interface type it supports.  Although this
   document considers the Driver to be part of the Attachment Daemon,
   current practice is to see it as a separate software unit running as
   a daemon "in front of" the Attachment Daemon.  The protocol for data
   exchange between the Driver and the Attachment Daemon is outside the
   scope of this document.

2.4.  Event

   A UPS event occurs in the Management Daemon when a change in the UPS
   status is received from the Attachment Daemon.  This event is
   internal to the Management Daemon.  See Section 5.2.

2.5.  Instant Command

   An Instant Command is a command that, when sent to the Attachment
   Daemon, is passed to the Driver and sent to the hardware without any
   configured delay to perform a function.  For example, INSTCMD su700
   test.panel.start.  See Section 4.2.6.

2.6.  Management Daemon

   The Management Daemon is primarily responsible for managing the
   hardware and orchestrating system-wide actions after a power event.
   Using commands sent to the Attachment Daemon, it follows the status
   of the UPS and determines when UPS events occur.  It takes decisions
   based on the events, such as calling for a system shutdown.  See
   Appendix B.  Although the term includes the word "Daemon", nothing
   requires that it be implemented as a detached software service.  The
   Management Daemon may also provide administrative functions, such as
   a graphic interface to view the hardware activity.

   There are several examples of a Management Daemon: the NUT Project
   provides upsmon, which takes the system shutdown decision when the
   public power supply fails.  Further configuration options, such as
   timers, are provided by the helper program upssched.

   Other programs represent the Management Daemon:

   *  upsc reports the values of the variables defined for a given UPS;
      see Table 6.
   *  upsrw reports on and changes the values of the readable and
      writable configuration variables defined for a given UPS; see
      Appendix A.2.
   *  upscmd reports on and executes the instant action commands defined
      for a given UPS; see Section 4.2.6.
   *  UPSmon.py is an experimental Python3 rewrite of upsmon and
      upssched that includes support for TLS 1.3 [RFC8446].

2.7.  Primary

   When a power device, such as a UPS unit, supplies power to more than
   one system, the computer running the Driver is known as the Primary.
   The others are Secondaries.  See Figure 4.  Common current practice
   for system administrators is to consider the Management Daemon in the
   Primary to be the Primary Management Daemon that is in charge of the
   shutdown of all the systems powered by the UPS.  The Primary
   Management Daemon sets status symbol FSD to order the Secondaries to
   shut down.

      |  Note: Historically, the Primary was known as the "Master".

2.8.  Secondary

   When a hardware device, such as a UPS unit, supplies power to more
   than one system, the system that communicates directly with the UPS
   unit, e.g., using a USB, RS-232, or a network connection, is known as
   the Primary.  The others are Secondaries.  There is no Attachment
   Daemon in a Secondary.  See Figure 4.  Common current practice for
   system administrators is to consider the Management Daemon in a
   Secondary to be a Secondary Management Daemon that understands status
   symbol FSD as an order to shut down.

      |  Note: Historically, the Secondary was known as the "Slave".

2.9.  Session

   The Management Daemon may initiate a TCP session with a specified
   device, such as a UPS known to the Attachment Daemon.  The session
   structure provides for audit and security, as well as access to
   mission-critical UPS functions.  For example, good practice requires
   password protection for an Instant Command that turns off a UPS
   outlet.  Other than the commands and responses used, the details of
   session management are outside the scope of this document.

2.10.  UPS Status

   The status of a hardware device, such as a UPS unit, is a symbolic
   description of the state of the unit.  It consists of a space-
   separated list of symbols from the set {ALARM BOOST BYPASS CAL CHRG
   COMM DISCHRG FSD LB NOCOMM OB OFF OL OVER RB TEST TRIM}.  The symbols
   TICK and TOCK are experimental additions to the statuses and are not
   in common current practice.  See Section 5.1, which specifies each of
   these symbols.

   See Section 8.2 for details of the recommended minimum support of
   status symbols OB, OL, LB, and FSD.

2.11.  UPS Variable

   The metrics and identifiers provided by each UPS are represented by
   variables giving the value representing that metric or identifier.
   The UPS variable is an abstraction of the UPS hardware configuration
   and activity maintained by the Attachment Daemon.  See Appendix A,
   which provides examples of variables.  For example, the variable
   battery.charge contains the current charge of the UPS battery as a
   percentage value.

   Note: Some variables are constants, e.g., battery type and
   manufacturer.

   See Section 8.2 for details of the recommended minimum support of
   variables.  A full list of possible variables is available in source
   code file docs/nut-names.txt [gitvars], which serves as the Recording
   Document.

3.  Protocol Overview

   Figure 1 shows a reference configuration in which the command/
   response protocol applies.  The UPS shown is representative of all
   managed power devices.

                                                    "The client"
                   ,--------------,               ,--------------,
         ,-----,   |     UPS      | <-Commands    |     UPS      |
         | UPS |---|  Attachment  |---------------|  Management  |
         |     |===|    Daemon    |   Responses-> |    Daemon    |
         /-----\   '--------------'               '--------------'
                    UPS Attachment                 UPS Management
                        System        Network          System

                     Figure 1: Reference Configuration

   The reference configuration in Figure 1 shows a single UPS unit that
   has a power supply link (===) and a data link (---) attached to a
   system running an Attachment Daemon.  The UPS provides power supply
   protection to the system running the Attachment Daemon.

   In practice, there may be more than one UPS unit, and a unit may
   provide power protection to more than one system.  The figure also
   shows a single Management Daemon.  In practice, there may be more
   than one Management Daemon, and any one Management Daemon may manage
   more than one UPS Attachment Daemon.

   The protocol applies to connections between the Attachment Daemon and
   the Management Daemon, which act as the *server* and *client*,
   respectively.  The Management Daemon sends commands over TCP to the
   Attachment Daemon and receives responses over TCP from that daemon.

   The two daemons may run in the same system or may be connected
   through a local or wide area network.  In simple cases, as shown in
   Figure 2, the Attachment Daemon and the Management Daemon are in the
   same system, the one protected by the UPS.  The commands and
   responses are exchanged through an internal loopback interface.

                                                   "The client"
                     ,--------------------,---------------------,
           ,-----,   |     UPS       <-Commands        UPS      |
           | UPS |---|  Attachment        |         Management  |
           |     |===|    Daemon       Responses->    Daemon    |
           /-----\   '--------------------'---------------------'
                                       Internal
                                       Loopback
                       UPS Attachment and Management System

              Figure 2: Simplified Single-System Configuration

   The reference configuration does not require any specific design.
   For example, Figure 3 shows an arrangement in which the Attachment
   Daemon is closely associated with, or even included in, the UPS
   system setup.  This is becoming more prevalent with the availability
   of low-cost processors able to run the Attachment Daemon, thereby
   effectively creating a network-attached UPS running a published
   protocol.

                                                 "The client"
            ,-----,------------,               ,--------------,
            |     |    UPS     | <-Commands    |     UPS      |
            | UPS - Attachment |---------------|  Management  |
            |     |   Daemon   |   Responses-> |    Daemon    |
            /-----'------------\               '--------------'
               UPS Attachment                   UPS Management
                   System           Network          System

              Figure 3: UPS and Attachment Daemon Integration

   As the power requirements for processors decrease, it is becoming
   increasingly common to use a single UPS to protect multiple systems,
   as shown in Figure 4.  However, there is only one data line (---)
   from the UPS to the Primary system.  The others have only power
   connections (===) to the UPS and are known as Secondaries.  A
   Secondary does not run an Attachment Daemon; it connects over a
   network to the Attachment Daemon in the Primary.  Figure 4 shows the
   Attachment Daemon and the Primary Management Daemon in the same
   system.  This is common practice, but it is not a technical
   requirement.

                                          "The client"
               ,--------------------,---------------------,
     ,-----,   |     UPS       <-Commands      Primary    |
     |     |---|  Attachment        |         Management  |   Primary
     |     |===|    Daemon       Responses->    Daemon    |
     |     |   '--------------------'---------------------'
     | UPS |            ^
     |     |            '<-Commands---Responses->,
     |     |                                     v
     |     |            ,--------------,-----------------,
     |     |============|              |     Secondary   |
     /-----\            |              |     Management  |   Secondary
                        |              |       Daemon    |
                        '--------------'-----------------'

                  Figure 4: UPS Protects Multiple Systems

      |  Note: Should the Primary fail or go offline, the fate of the
      |  Secondaries depends on the UPS status when the Primary failed.
      |  If the UPS had status OL, the Secondary continues operation,
      |  but if the UPS had status OB, the Secondary may choose to shut
      |  down as a precaution.

4.  Protocol Specification

   This specification includes only the commands and their responses.
   An implementation of the Attachment Daemon has an internal state
   machine, and some complex implementations of the Management Daemon
   include an internal state machine, for example, to assist the system
   shutdown of a complex installation.  The Management Daemon is
   required to remember the previous ups.status value it received from
   the Attachment Daemon and compare it with the next.  Other than that,
   the management protocol used between them is effectively stateless.

   For example, see Section 5.2, which shows a map of the new ups.status
   response and the previous ups.status response to an event, which is
   taken as the basis for Management Daemon action.

4.1.  Notation Used in this Specification

   The character set used for commands and responses is US-ASCII; see
   [RFC0020].

   Multi-word elements are contained between quotation mark characters
   for easier parsing, e.g., "UPS on fire".  Embedded quotation marks
   are escaped with reverse slant (\), often known as backslashes.
   Embedded backslashes are also escaped by representing them as \\.

   Commands and responses have no leading or trailing blank space and
   are terminated with a single new line character line feed (LF).

   Blank space within commands and responses is reduced to one space
   (SP).

4.2.  Commands

   The commands address the UPS to which they apply by <upsname>, where

   *  <upsname> ::= <ups>[@<hostname>[:<port>]]
   *  <ups> is defined by the Attachment Daemon configuration files.
   *  The default <hostname> is localhost.
   *  The <port> is the number of the TCP port on which the Attachment
      Daemon is listening.  The default is 3493.  This is supported by
      all current Management Daemons.

   Examples: myups, UPS-97B@bigserver.example.com

   ABNF: See variable upsname in Figure 5.

   Note: Experimental Management Daemons use an extended form of
   <upsname> in configuration files and in program parameters, where:

   *  <upsname> ::= [<group>:]<ups>[@<hostname>[:<port>]]
   *  <group> is an experimental extension to provide for groups of
      UPSs.  It is not in common current practice.
   *  <ups> is defined by the Attachment Daemon configuration files.
   *  The default <hostname> is localhost.

   Examples: ups-1@example.com:3493, HB:heartbeat1@example.com:3493

      |  _Implementation note:_ In the current implementation, the names
      |  of commands and subcommands are not case sensitive.  For
      |  example, GET VAR may be written as Get var, but in this
      |  specification, they are always written in uppercase.
      |  Similarly, <upsname> and <varname> are not case sensitive.  For
      |  example, UPS341 ups.id may be written as ups341 Ups.Id, but in
      |  this specification, <varname> is always written in lower case.

4.2.1.  ATTACH

   In a configuration like the one shown in Figure 4, in which a UPS
   protects more than one system, the Primary Management Daemon needs to
   know how many Secondaries are currently _active_, i.e., powered by
   the UPS, either from the public power supply or from battery power.
   The Attachment Daemon supports this by keeping a count of all the
   _active_ systems powered by a UPS.  The count is initialized, one
   Secondary at a time by the ATTACH command, which should be understood
   as _count this Secondary as active_.  ATTACH is one of three commands
   for Secondary counting.  Additionally, command DETACH decrements the
   count, and a Management Daemon may read the count at any time using
   the command NUMATTACH.

   The ATTACH command is also sent to the Attachment Daemon for the
   Primary, so during normal, fully protected operation, the count is 1
   for the Primary + the number of Secondaries.  During a full system
   shutdown, the count drops as each Secondary Management Daemon
   executes command DETACH during its own shutdown.  When the count
   drops to 1, only the Primary is _active_, and it knows that all the
   Secondaries have shut down.

   Command: ATTACH <upsname>

   If the command succeeds, the response is OK; otherwise, see the error
   responses in Section 4.3.2.

   ABNF: See variable attach in Figure 5.

      |  Note: Historically, this command was known as LOGIN.  However,
      |  because LOGIN was not the conventional user access to a shell
      |  or program, the name was changed to avoid confusion.

4.2.2.  DETACH

   This companion command to ATTACH reduces the count of "active"
   Secondaries.  It should be understood as _this Secondary is no longer
   active_ and is usually used during system shutdown to decrement a
   count of how many Secondaries are still _active_.

   Command: DETACH

   If the command succeeds, the response is OK Goodbye; otherwise, see
   the error responses in Section 4.3.2.

   ABNF: See variable detach in Figure 5.

      |  Note: Historically, this command was known as LOGOUT.

4.2.3.  FSD

   A Management Daemon that is Primary and has the required authority
   uses this command to set status symbol FSD, meaning "Forced
   Shutdown", in the Attachment Daemon.  In current practice, the
   Primary Management Daemon uses the symbol to tell the Secondaries to
   shut down.

   Command: FSD <upsname>

   If the command succeeds, the response is OK FSD-SET; otherwise, see
   the error responses in Section 4.3.2.

   ABNF: See variable fsd in Figure 5.

   In current practice, commands such as FSD are made available only to
   a privileged administrative user authorized to send such a mission-
   critical command.  The security provisions for administrative users
   are discussed in Appendix E.

   Note: The symbol FSD is also used for an event.  See Table 5.

4.2.4.  GET

   Retrieve a single response from the Attachment Daemon.

   ABNF: See variable get in Figure 5.

   The possible subcommands are listed in the sections below.

4.2.4.1.  GET CMDDESC

   Retrieve a text description of a command.

   Command: GET CMDDESC <upsname> <cmdname>

   Response: CMDDESC <upsname> <cmdname> "<description>"

   For example: command GET CMDDESC su700 load.on and response CMDDESC
   su700 load.on "Turn on the load immediately"

   This is like GET DESC, but it applies to an Instant Command.  See
   Section 4.2.4.2.

4.2.4.2.  GET DESC

   Retrieve a text description of a UPS variable.  See Section 2.11.

   Command: GET DESC <upsname> <varname>

   Response: DESC <upsname> <varname> "<description>"

   <description> is a string that gives a brief explanation of the named
   variable.  The Attachment Daemon MAY return "Unavailable" if the file
   that provides this description is not installed.

   For example: command GET DESC su700 ups.status and response DESC
   su700 ups.status "UPS status"

4.2.4.3.  GET NUMATTACH

   Retrieve the count kept by the Attachment Daemon of all the _active_
   systems protected by this UPS.

   Command: GET NUMATTACH <upsname>

   Response: NUMATTACH <upsname> <value>

   <value> is a count of the Primary and the number of Secondaries
   currently powered by this UPS.

   For example: command GET ATTACH su700 and response NUMATTACH su700 1

   This information is needed by the Management Daemon to determine how
   many Secondaries are still connected during the system shutdown
   process.

      |  Note: Historically, this subcommand was known as NUMLOGINS.
      |  Since LOGIN was not the conventional user access to a shell or
      |  program, the name was changed to avoid confusion.

4.2.4.4.  GET TYPE

   Retrieve the type of a UPS variable.  See Section 2.11.

   Command: GET TYPE <upsname> <varname>

   Response: TYPE <upsname> <varname> <type>...

   <type>... can be one or more of the following tokens.  Multiple types
   may be returned.

   For example: command GET TYPE su700 input.transfer.low and response
   TYPE su700 input.transfer.low ENUM

      +==============+==============================================+
      |     Type     |                   Meaning                    |
      +==============+==============================================+
      | RW           | This is a read/write variable.  It may be    |
      |              | read with command GET VAR (see               |
      |              | Section 4.2.4.6) and set to a different      |
      |              | value with command SET (see Section 4.2.11). |
      +--------------+----------------------------------------------+
      | ENUM         | This is an enumerated type, which supports   |
      |              | specific predetermined values.               |
      +--------------+----------------------------------------------+
      | STRING:n     | This is a string of maximum length n.        |
      +--------------+----------------------------------------------+
      | RANGE        | This is a number, either integer or float,   |
      |              | comprised in the range that may be seen with |
      |              | the command LIST RANGE (see                  |
      |              | Section 4.2.7.4).                            |
      +--------------+----------------------------------------------+
      | NUMBER       | This is a single numeric value, either       |
      |              | integer or float.                            |
      +--------------+----------------------------------------------+

                          Table 1: Variable Types

   Notes:

   *  ENUM, STRING:n, and RANGE are usually associated with RW but not
      always.  The default <type>, when omitted, is numeric, so either
      integer or float.  Each Driver is then responsible for handling
      values as either integer or float.

   *  Current practice is to represent floating point values using a
      decimal (base 10) English-based representation.  Hexadecimals,
      exponents, and commas used as separators for thousands are not
      allowed.  For example, "1200.20" is valid, while "1,200.20" and
      "1200,20" are not valid.

4.2.4.5.  GET UPSDESC

   Retrieve a text description of a UPS.

   Command: GET UPSDESC <upsname>

   Response: UPSDESC <upsname> "<description>"

   <description> is defined by the Attachment Daemon configuration.  If
   it is not set, current practice is for the Attachment Daemon to
   return "Unavailable".

   For example: command GET UPSDESC su700 and response UPSDESC su700
   "Development box"

   This can be used to provide human-readable descriptions, instead of a
   cryptic ups@hostname string.

4.2.4.6.  GET VAR

   Retrieve the value of a UPS variable.  See Section 2.11.

   Command: GET VAR <upsname> <varname>

   Response: VAR <upsname> <varname> "<value>"

   For example: command GET VAR su700 ups.status and response VAR su700
   ups.status "OB LB"

4.2.5.  HELP

   Return a list of the commands supported by the Attachment Daemon.
   This command is intended for human, as well as program, use.

   Command: HELP

   For example: the following command line sequence executed on an
   Attachment Daemon

   netcat localhost 3493
   HELP
   Commands: HELP VER GET LIST SET INSTCMD ATTACH DETACH
       USERNAME PASSWORD STARTTLS

   ABNF: See variable help in Figure 5.

      |  Note: Historically, this command also returned LOGIN and
      |  LOGOUT.  Because LOGIN was not the conventional user access to
      |  a shell or program, the command names were changed to ATTACH
      |  and DETACH to avoid confusion.

4.2.6.  INSTCMD

   Send an Instant Command to the UPS.

   Command: INSTCMD <upsname> <cmdname>

   <upsname> is the name of the UPS, and <cmdname> is the Instant
   Command to be issued to that UPS.  See Appendix A.3 for examples of
   Instant Commands.

   If the command succeeds, the response is OK; otherwise, see the error
   responses in Section 4.3.2.

   For example: command INSTCMD su700 test.panel.start and response OK

   ABNF: See variable instcmd in Figure 5.

4.2.7.  LIST

   All the LIST commands produce a response with a common format.  The
   response begins with BEGIN LIST and then repeats the initial query.
   A list then follows, with as many lines as are necessary.  The
   response ends with END LIST, followed by the initial query.

   The formatting may seem a bit redundant, but it makes a different
   form of client possible.  A client can send a LIST command and then
   wait for the response.  When it arrives, the Management Daemon
   doesn't need a complicated state machine to remember which list is
   which.

   Note: The current NUT Project implementation of the Attachment
   Daemon, upsd, sends back the response to the LIST command as a
   sequence of messages.  The Management Daemon should continue reading
   these messages until it receives the line beginning END LIST.

   ABNF: See the variable list in Figure 5.

   The possible subcommands are listed in the sections below.

4.2.7.1.  LIST CLIENT

   The command calls for the Attachment Daemon to report all the current
   Management Daemon clients of a given UPS.

   Command: LIST CLIENT <upsname>

   Response:

   BEGIN LIST CLIENT <upsname>
   CLIENT <upsname> <client_IP_address>
   ...
   END LIST CLIENT <upsname>

   For example: command LIST CLIENT ups1 and response

   BEGIN LIST CLIENT ups1
   CLIENT ups1 ::1
   CLIENT ups1 203.0.113.1
   END LIST CLIENT ups1

4.2.7.2.  LIST CMD

   The command calls for the Attachment Daemon to report a list of the
   Instant Commands that the Management Daemon may send to the
   Attachment Daemon.  This Instant Command list is the abstracted view
   of the UPS hardware capabilities.  An economical UPS will support few
   or no Instant Commands, but a professional model should support more.

   Command: LIST CMD <upsname>

   Response:

   BEGIN LIST CMD <upsname>
   CMD <upsname> <cmdname>
   ...
   END LIST CMD <upsname>

   <upsname> is the name of the UPS, and <cmdname> is the name of the
   Instant Command that may be issued to the UPS.

   For example: command LIST CMD su700 and response

   BEGIN LIST CMD su700
   CMD su700 load.on
   CMD su700 test.panel.start
   ...
   END LIST CMD su700

4.2.7.3.  LIST ENUM

   The command calls for the Attachment Daemon to report the set of
   possible values of a UPS variable that has predetermined values.

   Command: LIST ENUM <upsname> <varname>

   Response:

   BEGIN LIST ENUM <upsname> <varname>
   ENUM <upsname> <varname> "<value>"
   ...
   END LIST ENUM <upsname> <varname>

   <upsname> is the name of the UPS, <varname> is the UPS variable, and
   <value> is one of the possible values of that UPS variable.  Note
   that, in current practice, the output is an unordered list.  Also
   note that the quotation marks are part of the response.

   For example: command LIST ENUM su700 input.transfer.low and response

   BEGIN LIST ENUM su700 input.transfer.low
   ENUM su700 input.transfer.low "103"
   ENUM su700 input.transfer.low "100"
   ...
   END LIST ENUM su700 input.transfer.low

4.2.7.4.  LIST RANGE

   The command calls for the Attachment Daemon to report the interval in
   which valid values of UPS variable lie.

   Command: LIST RANGE <upsname> <varname>

   Response:

   BEGIN LIST RANGE <upsname> <varname>
   RANGE <upsname> <varname> "<min>" "<max>"
   ...
   END LIST RANGE <upsname> <varname>

   <upsname> is the name of the UPS, <varname> is the UPS variable, and
   {<min>,<max>} is the interval of valid values of that UPS variable.
   Note that the quotation marks are part of the response.

   For example: command LIST RANGE su700 input.transfer.low and response

   BEGIN LIST RANGE su700 input.transfer.low
   RANGE su700 input.transfer.low "90" "105"
   END LIST RANGE su700 input.transfer.low

4.2.7.5.  LIST RW

   The command calls for the Attachment Daemon to report a list of the
   UPS variables associated with a given UPS that may be read and
   written by the Management Daemon.  These variables are the abstracted
   view of the UPS hardware capabilities.  An economical UPS may support
   few variables, but a professional model should support at least the
   variables that are needed for an automatic shutdown and restart; see
   Appendix B.  Also, see Section 8.2 for details of the recommended
   minimum support of variables.  A full list of variables is available
   in source code file docs/nut-names.txt [gitvars], which serves as the
   Recording Document.

   Command: LIST RW <upsname>

   Response:

   BEGIN LIST RW <upsname>
   RW <upsname> <varname> "<value>"
   ...
   END LIST RW <upsname>

   <upsname> is the name of the UPS, <varname> is the UPS variable, and
   <value> is the value of that UPS variable.  Note that the quotation
   marks are part of the response.

   For example: command LIST RW su700 and response

   BEGIN LIST RW su700
   RW su700 output.voltage.nominal "115"
   RW su700 ups.delay.shutdown "020"
   ...
   END LIST RW su700

4.2.7.6.  LIST UPS

   The command calls for the Attachment Daemon to report a list of the
   UPS units to which it is attached.

   Command: LIST UPS

   Response:

   BEGIN LIST UPS
   UPS <upsname> "<description>"
   ...
   END LIST UPS

   <upsname> is the name of a UPS, and <description> is the description
   maintained by the Attachment Daemon, if available.  It is set to
   "Unavailable" otherwise.  Note that the quotation marks are part of
   the response.

   This command can also be used to determine what values of <upsname>
   are valid before calling other functions on the server.  This is also
   a good way to handle situations where a single Attachment Daemon
   supports multiple UPSs.  It is also useful for clients that perform a
   UPS discovery process.

   For example: response

   BEGIN LIST UPS
   UPS su700 "Development box"
   END LIST UPS

4.2.7.7.  LIST VAR

   The command calls for the Attachment Daemon to report a list of all
   the UPS variables that it maintains for a given UPS and the values of
   those UPS variables.

   Command: LIST VAR <upsname>

   Response:

   BEGIN LIST VAR <upsname>
   VAR <upsname> <varname> "<value>"
   ...
   END LIST VAR <upsname>

   <upsname> is the name of the UPS, <varname> is the UPS variable, and
   <value> is the value of that variable.  Note that the quotation marks
   are part of the response.

   The response to this command lists the UPS variables available for
   this UPS and their current values.

   For example: command LIST VAR su700 and response

   BEGIN LIST VAR su700
   VAR su700 ups.mfr "Example Mfg"
   VAR su700 ups.mfr.date "10/17/96"
   ...
   END LIST VAR su700

   See Section 8.2 for details of the recommended minimum support of
   variables.  A full list of variables is available in source code file
   docs/nut-names.txt [gitvars], which serves as the Recording Document.

4.2.8.  PASSWORD

   This command is a companion to USERNAME and is used by a Management
   Daemon to specify the password required to enter a session with the
   Attachment Daemon; see Section 2.9.

   Command: PASSWORD <password>

   If the command succeeds, the response is OK; otherwise, see the error
   responses in Section 4.3.2.

   For examples of the use of commands USERNAME and PASSWORD by
   administrative users, see Appendix E.2.

   ABNF: See variable session-password in Figure 5.

4.2.9.  PRIMARY

   In current practice, the Attachment Daemon records in local file
   upsd.users that an administrative user is a Primary.  See
   Appendix E.1 for an example.  When a Management Daemon starts up and
   opens a session with the Attachment Daemon, it lays claim to being a
   Primary by sending command PRIMARY to the Attachment Daemon, thus
   claiming that it has the required authority to perform critical
   actions, such as setting status symbol FSD.

   Command: PRIMARY <upsname>

   <upsname> is the name of the UPS.

   If the Attachment Daemon has the authority, the response is OK;
   otherwise, see the error responses in Section 4.3.2.

      |  Note: Historically, this command was known as MASTER.

4.2.10.  PROTVER

   Return the version of the command/response protocol used by the
   Attachment Daemon.  This command is intended for human, as well as
   program, use.

   Command: PROTVER

   For example: the following command line sequence in the Attachment
   Daemon

   netcat localhost 3493
   PROTVER
   1.3

   Notes:

   1.  There are no quotation marks in the response.
   2.  The version of the protocol returned by PROTVER is different than
       the implementation version of the Attachment Daemon returned by
       VER.
   3.  To ease migration, NUT version 2.8.0 also supports the equivalent
       NETVER command used in previous releases.  See Section 8.2.4.

   ABNF: See variable protver in Figure 5.

4.2.11.  SET

   The command calls for the Attachment Daemon to set a UPS variable to
   a given value.  Whether this has an effect on the UPS hardware is
   specific to the Driver and the UPS model.  Some variables are read-
   only due to the design of the UPS or its Driver.

   Command: SET VAR <upsname> <varname> "<value>"

   <upsname> is the name of the UPS, <varname> is the UPS variable, and
   <value> is the value to be assigned to that variable.  Note that the
   quotation marks are part of the command.

   If the command succeeds, the response is OK; otherwise, see the error
   responses in Section 4.3.2.

   For example: command SET VAR su700 ups.id "My UPS" and response OK

   ABNF: See the variable set in Figure 5.

4.2.12.  STARTTLS

   The client tells the Attachment Daemon to switch to communication
   encrypted by TLS [RFC8446].  When the client receives OK, it also
   switches to TLS encryption.

   Command: STARTTLS

   If the command succeeds, the response is OK STARTTLS; otherwise, see
   the error responses in Section 4.3.2.

   If the client does not send command STARTTLS to the Attachment
   Daemon, communication continues unencrypted; however, an Attachment
   Daemon MAY refuse unencrypted communication.

   NUT 2.8.0 supports the encryption of communications between the
   Attachment Daemon and the Management Daemon using TLS 1.3 [RFC8446]
   with X.509 v3 certificates, as defined by [RFC5280] and updates.  See
   Appendix D for details of the encryption of communications in
   previous release 2.7.4.

   ABNF: See variable starttls in Figure 5.

4.2.12.1.  Key Infrastructure and Self-Signed Certificates

   _The very restricted nature of UPS management makes it of interest to
   consider self-signed certificates._

   In the World Wide Web, there are millions of servers and hundreds of
   millions of potential clients for each one.  The servers do not know
   who their clients will be, so they entrust the management of a Public
   Key Infrastructure (PKI) to Certificate Authorities that they trust.
   The encryption of communications between the client and server
   requires that the browsers carry a list of Certificate Authorities
   that the clients have to trust.  _This is a many-to-many
   relationship._

   The management of UPS units is not a many-to-many relationship; it is
   frequently one to one.  In the closely restrained world of UPS
   management, there are a very limited number of clients for each
   server, rarely more than three, and unlike the World Wide Web, the
   server administrators know exactly who they are.  These clients visit
   very few servers, typically one only.  This situation is totally
   different from the World Wide Web.  The use of external Certificate
   Authorities is a potential security weakness that must be accepted
   for the World Wide Web but which can be avoided for UPS management by
   either generating the private and public keys locally or, for larger
   organizations, using a PKI.

   The security policies for UPS management may be subordinate to an
   organization's own internal IT security plans and procedures,
   possibly based on [RFC7030] and [RFC8894], but in simple cases, it is
   possible to obtain better security using self-signed certificates.

4.2.13.  USERNAME

   The Attachment Daemon limits access to clients whose credentials
   match those in the file upsd.users.  There is no anonymous access.  A
   Management Daemon program or script uses command USERNAME and its
   companion command PASSWORD to open a session with the Attachment
   Daemon for an administrative user.  Note that this command is for
   program or script use and is not the familiar login command typed on
   a command line to gain access to a shell.

   Command: USERNAME <username>

   If the command succeeds, the response is OK; otherwise, see the error
   responses in Section 4.3.2.

   For examples of the use of commands USERNAME and PASSWORD by
   administrative users, see Appendix E.2.

   ABNF: See variable session-username in Figure 5.

4.2.14.  VER

   Return the implementation version of the Attachment Daemon.  This
   command is intended for human, as well as program, use.

   Command: VER

   For example: the following command line sequence

   netcat localhost 3493
   VER
   Network UPS Tools upsd 2.8.0 - http://www.networkupstools.org/

   Notes:

   1.  There are no quotation marks in the response.
   2.  The implementation version of the Attachment Daemon returned by
       VER is different than the protocol version returned by PROTVER.

   ABNF: See variable ver in Figure 5.

4.3.  Summary of Responses

4.3.1.  Response When Command Succeeds

   If the command succeeds, the response has the following command-
   dependent form:

     +==========+=====================+================+============+
     | Command  | Response            | Reference      | Note       |
     +==========+=====================+================+============+
     | ATTACH   | OK                  | Section 4.2.1  | Was LOGIN  |
     +----------+---------------------+----------------+------------+
     | DETACH   | OK Goodbye          | Section 4.2.2  | Was LOGOUT |
     +----------+---------------------+----------------+------------+
     | FSD      | OK FSD-SET          | Section 4.2.3  |            |
     +----------+---------------------+----------------+------------+
     | GET      | Subcommand specific | Section 4.2.4  |            |
     +----------+---------------------+----------------+------------+
     | HELP     | List of commands    | Section 4.2.5  |            |
     +----------+---------------------+----------------+------------+
     | INSTCMD  | OK                  | Section 4.2.6  |            |
     +----------+---------------------+----------------+------------+
     | LIST     | Subcommand specific | Section 4.2.7  |            |
     +----------+---------------------+----------------+------------+
     | PASSWORD | OK                  | Section 4.2.8  |            |
     +----------+---------------------+----------------+------------+
     | PRIMARY  | OK                  | Section 4.2.9  |            |
     +----------+---------------------+----------------+------------+
     | PROTVER  | Protocol version    | Section 4.2.10 | Was NETVER |
     +----------+---------------------+----------------+------------+
     | SET      | OK                  | Section 4.2.11 |            |
     +----------+---------------------+----------------+------------+
     | STARTTLS | OK STARTTLS         | Section 4.2.12 |            |
     +----------+---------------------+----------------+------------+
     | USERNAME | OK                  | Section 4.2.13 |            |
     +----------+---------------------+----------------+------------+
     | VER      | Program version     | Section 4.2.14 |            |
     +----------+---------------------+----------------+------------+

                  Table 2: Response If Command Succeeds

4.3.2.  Error Responses

   Error responses have the following format:

   ERR <error-name> [<extra>]

   <error-name> is a single word token taken from the 27 characters A-Z
   and hyphen (-).  Implementations MAY, if needed, add an additional,
   optional <extra>.  Current practice does not make use of this
   possibility.

   The <error-name> may have one of the following values:

    +==============================+==================================+
    |   The Error Name Token       |             Meaning              |
    |         <error-name>         |                                  |
    +==============================+==================================+
    | ACCESS-DENIED                | The client's host and/or         |
    |                              | authentication details supplied  |
    |                              | by USERNAME and PASSWORD are not |
    |                              | sufficient to execute the        |
    |                              | requested command.               |
    +------------------------------+----------------------------------+
    | ALREADY-ATTACHED             | The client has already sent a    |
    |                              | successful ATTACH command for a  |
    |                              | given UPS and can't do it again. |
    +------------------------------+----------------------------------+
    | ALREADY-SET-PASSWORD         | The client has already supplied  |
    |                              | a PASSWORD and is attempting to  |
    |                              | repeat the command in the same   |
    |                              | session.                         |
    +------------------------------+----------------------------------+
    | ALREADY-SET-USERNAME         | The client has already supplied  |
    |                              | a USERNAME and is attempting to  |
    |                              | repeat the command within the    |
    |                              | same session.                    |
    +------------------------------+----------------------------------+
    | CMD-NOT-SUPPORTED            | The specified UPS doesn't        |
    |                              | support the Instant Command.     |
    +------------------------------+----------------------------------+
    | DATA-STALE                   | The Attachment Daemon is         |
    |                              | connected to the Driver for the  |
    |                              | UPS, but that Driver isn't       |
    |                              | providing regular updates or has |
    |                              | specifically marked the data as  |
    |                              | stale.  Current practice is for  |
    |                              | the Attachment Daemon to refuse  |
    |                              | to provide the Management Daemon |
    |                              | with variables on stale units to |
    |                              | avoid false readings.            |
    |                              |                                  |
    |                              | This generally means that the    |
    |                              | Driver is running, but it has    |
    |                              | lost communication with the      |
    |                              | hardware.  Check the physical    |
    |                              | connection to the equipment.     |
    +------------------------------+----------------------------------+
    | DRIVER-NOT-CONNECTED         | The Attachment Daemon can't      |
    |                              | perform the requested command,   |
    |                              | since the Driver for that UPS is |
    |                              | not connected.  This usually     |
    |                              | means that the Driver is not     |
    |                              | running or, if it is, is         |
    |                              | misconfigured.                   |
    +------------------------------+----------------------------------+
    | FEATURE-NOT-CONFIGURED       | This instance of the Attachment  |
    |                              | Daemon hasn't been configured    |
    |                              | properly to allow the requested  |
    |                              | feature to operate.  In current  |
    |                              | practice, this error response is |
    |                              | possible only for command        |
    |                              | STARTTLS.                        |
    +------------------------------+----------------------------------+
    | FEATURE-NOT-SUPPORTED        | This instance of Attachment      |
    |                              | Daemon does not support the      |
    |                              | requested feature.  In current   |
    |                              | practice, this error response is |
    |                              | possible only for command        |
    |                              | STARTTLS.                        |
    +------------------------------+----------------------------------+
    | INSTCMD-FAILED               | The Attachment Daemon failed to  |
    |                              | deliver the Instant Command      |
    |                              | request to the Driver.  No       |
    |                              | further information is available |
    |                              | to the client.  This typically   |
    |                              | indicates a dead or broken       |
    |                              | Driver.                          |
    +------------------------------+----------------------------------+
    | INVALID-ARGUMENT             | The client sent an argument to a |
    |                              | command that is not recognized   |
    |                              | or is otherwise not valid in     |
    |                              | this context.  This is typically |
    |                              | caused by sending a valid        |
    |                              | command, such as GET, with a     |
    |                              | subcommand that is not valid.    |
    +------------------------------+----------------------------------+
    | INVALID-PASSWORD             | The client sent a nonvalid       |
    |                              | PASSWORD.                        |
    +------------------------------+----------------------------------+
    | INVALID-USERNAME             | The client sent a nonvalid       |
    |                              | USERNAME.                        |
    +------------------------------+----------------------------------+
    | INVALID-VALUE                | The value specified in the       |
    |                              | request is not valid.  This      |
    |                              | usually applies to a SET of an   |
    |                              | ENUM type that is using a value  |
    |                              | not in the list of allowed       |
    |                              | values.  See Section 4.2.7.3.    |
    +------------------------------+----------------------------------+
    | PASSWORD-REQUIRED            | The command requires a PASSWORD  |
    |                              | for authentication, but the      |
    |                              | client hasn't provided one.      |
    +------------------------------+----------------------------------+
    | READONLY                     | The requested variable in a SET  |
    |                              | command is not writable.         |
    +------------------------------+----------------------------------+
    | SET-FAILED                   | The Attachment Daemon failed to  |
    |                              | deliver the SET request to the   |
    |                              | Driver.  This is similar to      |
    |                              | INSTCMD-FAILED.                  |
    +------------------------------+----------------------------------+
    | TLS-ALREADY-ENABLED          | TLS mode is already enabled on   |
    |                              | this connection, so the          |
    |                              | Attachment Daemon can't start it |
    |                              | again.                           |
    |                              |                                  |
    |                              | Note: Historically, this message |
    |                              | was ALREADY-SSL-MODE.            |
    +------------------------------+----------------------------------+
    | TLS-NOT-ENABLED              | TLS mode is required but has not |
    |                              | yet been enabled on this         |
    |                              | connection, so the Attachment    |
    |                              | Daemon can't send commands.      |
    |                              |                                  |
    |                              | Note: This message is            |
    |                              | experimental and not in current  |
    |                              | common use.                      |
    +------------------------------+----------------------------------+
    | TOO-LONG                     | The requested value in a SET     |
    |                              | command is too long.             |
    +------------------------------+----------------------------------+
    | UNKNOWN-COMMAND              | The Attachment Daemon doesn't    |
    |                              | recognize the command.           |
    +------------------------------+----------------------------------+
    | UNKNOWN-UPS                  | The UPS specified in the request |
    |                              | is not known to the Attachment   |
    |                              | Daemon.  This usually means that |
    |                              | it didn't match anything in the  |
    |                              | Attachment Daemon configuration. |
    +------------------------------+----------------------------------+
    | USERNAME-REQUIRED            | The command requires a USERNAME  |
    |                              | for authentication, but the      |
    |                              | client hasn't provided one.      |
    +------------------------------+----------------------------------+
    | VAR-NOT-SUPPORTED            | The specified UPS doesn't        |
    |                              | support the UPS variable in the  |
    |                              | command.                         |
    +------------------------------+----------------------------------+

                          Table 3: Error Responses

      |  Note: Historically, this error response was ALREADY-LOGGED-IN.

4.4.  An ABNF of the Commands

   This section repeats the syntax of Section 4.2 but in Augmented
   Backus-Naur Form (ABNF).  It does not define any additional features.
   For further details of each command and the response, see
   Section 4.2.

   The commands may be presented in ABNF [RFC5234] [RFC7405] and
   represented using US-ASCII [RFC0020].

   Current practice tolerates mixed-case command names, but it is
   RECOMMENDED to use uppercase only for commands.  See Figure 5.

   ;-------------------------------------------------------------------
   ; This grammar is case sensitive. Terminal keywords SHOULD be
   ; written in uppercase, as shown.
   ; The following basic rules written with uppercase names are
   ; taken from RFC 5234, Appendix B.1.
      SP = 1*%x20                  ; At least one SPACE
      LF = %x0A                    ; Linefeed
      DIGIT = %x30-39              ; Digit 0 through 9
      ALPHA =  %x41-5A / %x61-7A   ; A-Z / a-z
      DQUOTE = %x22                ; Double quote "
      VCHAR = %x21-7E              ; Visible (printing) characters
   ; Additional basic rules needed by this grammar
      LC = %x61-7A                 ; Letter a through z
      DOT = 1%x2E                  ; Exactly one .
      COLON = 1%x3A                ; Exactly one :
      AT = 1%x40                   ; Exactly one @
      SEP = 1"-" / 1"_" / 1"."     ; A single - or _ or .
      JOIN = COLON / AT            ; A single : or @
   ; Frequently used in this grammar
      cmdname = 1*LC *62(DOT 1*LC) ; E.g., load.off.delay
      upschar = DIGIT / ALPHA / SEP
      ups = 1*ALPHA *62upschar     ; E.g., Example-Mfg-999
      group = ups                  ; E.g., HB  (Not in common use)
      hostname = ups               ; E.g., example.com
      port = 1*5DIGIT              ; E.g., 3493
      upsname = [group COLON] ups [AT hostname [COLON port]]
                                   ; Fully Qualified UPS name
                                   ; E.g.,
                                   ; HB:heartbeat1@example.com:3493
      username = ups               ; E.g., Power-Dept.6
      varname = 1*LC *62( DOT 1*(DIGIT / LC) )
                                   ; E.g., outlet.1.status
   ;-------------------------------------------------------------------
      commandLine = command LF     ; LF is a single %x0A
      command = attach / detach / fsd / get / help / instcmd /
                list / password / primary / protver / set /
                starttls / username / ver
   ;
      attach  = "ATTACH" SP upsname
   ;
      detach = "DETACH"
   ;
      fsd = "FSD" SP upsname
   ;
      get = "GET" SP getsubcommnd
      getsubcommand = getcmddesc / getdesc / getnumattach /
                      gettype / getupsdesc / getvar
   ;
      getcmddesc =   "CMDDESC" SP upsname SP cmdname
      getdesc =      "DESC" SP upsname SP varname
      getnumattach = "NUMATTACH" SP upsname
      gettype =      "TYPE" SP upsname SP varname
      getupsdesc =   "UPSDESC" SP upsname
      getvar =       "VAR" SP upsname SP varname
   ;
      help = "HELP"
   ;
      instcmd = "INSTCMD" SP upsname SP cmdname
   ;
      list = "LIST" listsubcommand
      listsubcommand = listclient / listcmd / listenum / listrange /
                       listrw / listups / listvar
   ;
      listclient = "CLIENT" SP upsname
      listcmd =    "CMD" SP upsname
      listenum =   "ENUM" SP upsname SP varname
      listrange =  "RANGE" SP upsname SP varname
      listrw =     "RW" SP upsname
      listups =    "UPS"
      listvar =    "VAR" SP upsname
   ;
      session-password = "PASSWORD" SP *63VCHAR
                            ; A sequence of printable characters defined
                            ; in a server configuration file.  Local
                            ; security practices may mandate a minimum
                            ; and maximum number of characters.
   ;
      primary = "PRIMARY" SP upsname
   ;
      protver = "PROTVER"
   ;
      value = *63VCHAR      ; Local practices may limit the choice of
                            ; characters and require non-US-ASCII.
      set = "SET" SP %s"VAR" SP upsname SP varname SP
            DQUOTE value DQUOTE
   ;
      starttls = "STARTTLS"
   ;
      session-username = "USERNAME" SP username
   ;
      ver = "VER"
   ;-------------------------------------------------------------------

                      Figure 5: ABNF for the Commands

   Notes:

   1.  _Implementation note:_ The ABNF is written using the provisions
       of [RFC5234] and [RFC7405], which are US-ASCII based [RFC0020].

   2.  The grammar is case sensitive.  The terminal key words SHOULD be
       written in uppercase, as specified.

   3.  The repetition factor in front of an expression has the form
       <min>*<max>, where <min> is the minimum number of repetitions,
       and <max> is the maximum number.

   4.  If <min> is omitted, its value is 0.  If <max> is omitted, its
       value is infinity.

   5.  The notation n*n, meaning "exactly n copies", may be written as
       n.

   6.  Square brackets around an expression mean that the expression is
       optional.  This could be written as 0*1.

4.4.1.  Responses to Commands

   The responses to the commands are encoded in US-ASCII [RFC0020] and
   fall into two groups:

   1.  Short replies to action commands; see Section 4.3.

   2.  Long replies to requests for information.  In this case, the
       reply is sent in a sequence of messages.  The last message will
       contain a line beginning END LIST . For example, see
       Section 4.2.7.1.

5.  Statuses and Events

5.1.  Status Symbols

   These symbols resume the abstracted view of the UPS hardware
   maintained by the Attachment Daemon.  The variable ups.status
   contains one or more space-separated status symbols, which together
   describe the UPS state at that instant.  In current practice, the
   Management Daemon will poll variable ups.status every 5 seconds with
   a command, such as GET VAR su700 ups.status, and a response, such as
   VAR su700 ups.status "OB LB", to discover changes in the UPS status.
   These changes will indicate UPS events.

    +=========+======================================================+
    |  Status |                       Meaning                        |
    |  Symbol |                                                      |
    +=========+======================================================+
    | ALARM   | The UPS reports that it requires intervention.       |
    +---------+------------------------------------------------------+
    | BOOST   | The UPS has determined that the voltage level of the |
    |         | public power supply is too low and is boosting it to |
    |         | the required level.  The UPS continues to supply the |
    |         | protected system from the public power supply.       |
    +---------+------------------------------------------------------+
    | BYPASS  | The UPS is feeding current directly from the public  |
    |         | power supply to the protected system.  The backup    |
    |         | facilities are disconnected.  This state allows      |
    |         | maintenance personnel to change the batteries        |
    |         | without interrupting the protected system.           |
    +---------+------------------------------------------------------+
    | CAL     | The UPS is calibrating itself, for example, to       |
    |         | determine at what charge the LB status is raised or  |
    |         | lowered.                                             |
    +---------+------------------------------------------------------+
    | CHRG    | The UPS battery is charging.  This usually implies   |
    |         | that the UPS also has status OL but may not be the   |
    |         | case if the UPS also has status OFF.                 |
    +---------+------------------------------------------------------+
    | COMM    | The Attachment Daemon has effective contact with the |
    |         | UPS.                                                 |
    +---------+------------------------------------------------------+
    | DISCHRG | The UPS battery is discharging.  This usually        |
    |         | implies that the UPS also has status OB but may not  |
    |         | be the case if the UPS also has status OFF.          |
    +---------+------------------------------------------------------+
    | FSD     | This "Forced Shutdown" status signals that the final |
    |         | shutdown sequence has begun.                         |
    +---------+------------------------------------------------------+
    | LB      | Low Battery.  The battery level of the UPS is below  |
    |         | a chosen limit.  The UPS may be in status OL or OB.  |
    +---------+------------------------------------------------------+
    | NOCOMM  | The Attachment Daemon has no effective contact with  |
    |         | the UPS.                                             |
    +---------+------------------------------------------------------+
    | OB      | On Battery.  The UPS is taking energy from its       |
    |         | battery.  The battery is discharging.  A UPS must    |
    |         | have status OB or OL; otherwise, it is deemed dead.  |
    +---------+------------------------------------------------------+
    | OFF     | The UPS is in state "Off".  It does not react to     |
    |         | failure in the public power supply.  The exact       |
    |         | meaning depends on the model.                        |
    +---------+------------------------------------------------------+
    | OL      | Online.  The UPS is online, receiving energy from    |
    |         | the public power supply.  The battery is charging.   |
    |         | A UPS must have status OB or OL; otherwise, it is    |
    |         | deemed dead.                                         |
    +---------+------------------------------------------------------+
    | OVER    | Overloaded.  The UPS reports that the load on it is  |
    |         | beyond its normal operating maximum.                 |
    +---------+------------------------------------------------------+
    | RB      | Replace battery.  The UPS reports that its battery   |
    |         | or batteries should be replaced.                     |
    +---------+------------------------------------------------------+
    | TEST    | Under test.  The UPS is currently undergoing a test  |
    |         | that may have been requested manually or internally. |
    +---------+------------------------------------------------------+
    | TICK    | Heartbeat.  A software UPS in the Attachment Daemon  |
    |         | provides a regular signal monitored by the           |
    |         | Management Daemon as a way of verifying effective    |
    |         | end-to-end management.  TICK and TOCK are            |
    |         | companions; they are considered experimental.        |
    +---------+------------------------------------------------------+
    | TOCK    | Heartbeat.  See TICK                                 |
    +---------+------------------------------------------------------+
    | TRIM    | The UPS has determined that the voltage level of the |
    |         | public power supply is too high and is reducing it   |
    |         | to the required level.  The UPS continues to supply  |
    |         | the protected system from the public power supply.   |
    +---------+------------------------------------------------------+

                       Table 4: UPS Status Symbols

5.2.  Events

   A Management Daemon detects the occurrence of a UPS event from a
   change in the UPS status received from the Attachment Daemon.  The
   following table summarizes the process.  A status of "none" means
   that the status symbol is not present in the variable ups.status.

   The Management Daemon should retrieve the variable ups.status from
   the Attachment Daemon at regular intervals.  If the interval is too
   short, compute and network resources will be wasted, but if the
   interval is too large, the Management Daemon risks missing short-
   lived changes in the UPS status.

   A default value of 5 seconds is RECOMMENDED, but an implementation
   MAY make this value configurable.  By default, the "old" status is
   therefore the previous value retrieved 5 seconds ago.

   Current practice is for the Management Daemon to assign names to
   certain events.  These are shown in the table in parentheses.

   +=======+=========+===============++=========+========+=============+
   |Old    | New     |Event          || Old     | New    |Event        |
   |Status | Status  |               || Status  | Status |             |
   +=======+=========+===============++=========+========+=============+
   |none   | ALARM   |Alarm on       || ALARM   | none   |Alarm off    |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | BOOST   |Boosting       || BOOST   | none   |Not boosting |
   |       |         |voltage        ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | BYPASS  |Bypass on      || BYPASS  | none   |Bypass off   |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | CAL     |Calibrating    || CAL     | none   |Not          |
   |       |         |               ||         |        |calibrating  |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | CHRG    |Charging       || CHRG    | none   |Not charging |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | COMM    |UPS            || COMM    | none   |See note 4   |
   |       |         |communicating  ||         |        |             |
   |       |         |(event COMMOK) ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | DISCHRG |Discharging    || DISCHRG | none   |Not          |
   |       |         |               ||         |        |discharging  |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | FSD     |System shutdown|| FSD     | none   |Shutdown     |
   |       |         |(events FSD,   ||         |        |abandoned.   |
   |       |         |SHUTDOWN)      ||         |        |See note 1   |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | LB      |Low battery.   || LB      | none   |Battery not  |
   |       |         |See note 2     ||         |        |low          |
   |       |         |(event LOWBATT)||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | NOCOMM  |UPS dead?  See || NOCOMM  | none   |See note 4   |
   |       |         |note 4         ||         |        |             |
   |       |         |(events        ||         |        |             |
   |       |         |COMMBAD,       ||         |        |             |
   |       |         |NOCOMM)        ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | OFF     |UPS turned off || OFF     | none   |UPS not      |
   |       |         |               ||         |        |turned off   |
   +-------+---------+---------------++---------+--------+-------------+
   |OB     | OL      |Receiving power|| OL      | OB     |Power lost   |
   |       |         |(event ONLINE) ||         |        |(event       |
   |       |         |               ||         |        |ONBATT)      |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | OVER    |UPS overloaded || OVER    | none   |Overload gone|
   +-------+---------+---------------++---------+--------+-------------+
   |none   | RB      |Replace battery|| RB      | none   |Replacement  |
   |       |         |(event         ||         |        |canceled     |
   |       |         |REPLBATT)      ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | TEST    |Test starts    || TEST    | none   |Test finished|
   +-------+---------+---------------++---------+--------+-------------+
   |none   | TICK    |Heartbeat      || TICK    | none   |No heartbeat.|
   |       |         |event.  See    ||         |        |See note 3   |
   |       |         |note 3         ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | TOCK    |Heartbeat      || TOCK    | none   |No heartbeat.|
   |       |         |event.  See    ||         |        |See note 3   |
   |       |         |note 3         ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+
   |none   | TRIM    |Trimming       || TRIM    | none   |Not trimming |
   |       |         |voltage        ||         |        |             |
   +-------+---------+---------------++---------+--------+-------------+

                Table 5: Event Deduction from Status Changes

   Notes:
      1.  Current practice does not include this event.
      2.  If the status OB is present, current practice takes Management
          Daemon reception of LB as an order to perform an emergency
          system shutdown.
      3.  The use of a software-defined UPS to provide a heartbeat is
          experimental and is not part of common current practice.
      4.  Current practice is the following: if the UPS has not
          responded for 15 seconds, the Management Daemon assumes that
          the UPS is _dead_ (event NOCOMM), and if the last known OL/OB
          status was OB, a system shutdown (command FSD) is requested.

6.  Security Considerations

6.1.  Current General Security Practice

   Experience over the last 20 years shows that new UPS management
   software releases are not frequent and, when installed, stay
   unmodified for some years.  This is probably because UPS management
   is a mature activity, part of site management.  A limited number of
   system administrators have access to the UPS hardware and software
   and tend to assume a certain "security by obscurity" since many
   installations have a configuration like the one shown in Figure 6,
   which uses port 3493/TCP (nut) between the two daemons running in the
   same system.  The traffic is often not encrypted, and when it is
   encrypted, it uses deprecated early versions of SSL/TLS.

           ,-----,   ,--------------------,---------------------,
           | UPS |---|  Attachment   <-Commands     Management  |
           |     |===|    Daemon       Responses->    Daemon    |
           /-----\   '--------------------'---------------------'
                        Listens on
                       port 3493/TCP
                       for localhost

                Figure 6: Common Single-System Configuration

   This situation is now changing as low-cost processors become
   available, costing significantly less than a UPS unit.  This
   evolution makes it interesting to shift to a configuration like the
   one shown in Figure 7, but it also exacerbates the security weakness
   of Figure 6, since the traffic between the daemons is now over an
   exposed network.

            ,-----,------------,               ,--------------,
            | UPS - Attachment | <-Commands    |  Management  |
            |     |   Daemon   |   Responses-> |    Daemon    |
            /-----'------------\               '--------------'
                    Listens on
                   port 3493/TCP

             Figure 7: Integration of UPS and Attachment Daemon

   These security issues raised by UPS management are those of the power
   industry in general; they are addressed in detail in IEC Technical
   Specification 62351 [IEC62351-1].  In addition to equipment security,
   cyber security is now an essential consideration.

   Quoting from IEC 62351-1[IEC62351-1], Introduction to the standard,
   clause 5.2.3.5:

   |  With the computer systems for power operations presumably kept
   |  isolated from the Internet, many utility personnel do not see any
   |  reason for adding security measures to these systems.  However, as
   |  clearly seen from these Subclauses, this may not be true anymore
   |  as networking becomes more prevalent and additional information
   |  access requirements grow.

   In IEC 62351-1[IEC62351-1], clause 5.3.5 lists typical security
   attacks: Eavesdropping, Masquerade, Man-in-the-Middle, Replay, and
   Resource Exhaustion.  [RFC3552] adds message insertion/deletion/
   modification and denial of service.

   Let's look more closely at these requirements:

   *  Eavesdropping; see Section 6.3.1

   *  Man-in-the-Middle; see Section 6.3.2

   *  Masquerade; see Section 6.3.3

   *  Message insertion, deletion, and modification; see Section 6.3.4

   *  Replay; see Section 6.3.5

   *  Resource Exhaustion and Denial of Service; see Section 6.3.6

6.2.  Communication Security Requirements

   Enforcing secure communication requires tightening up the Attachment
   Daemon to require the use of command STARTTLS for commands sent over
   the global Internet.  In such a situation, an Attachment Daemon
   listening for traffic other than from localhost:

   1.  SHOULD require and accept command STARTTLS,

   2.  MUST encrypt all communication with a Management Daemon, and

   3.  SHALL refuse all non-encrypted commands, except an initial
       STARTTLS.

   Notes:

   *  The SHOULD, rather than MUST, in Section 6.2, Paragraph 2, Item 1
      above allows system administrators to enforce secure communication
      using other techniques that do not involve the STARTTLS command.

   *  If an Attachment Daemon requires that all commands be encrypted as
      required by the MUST in Section 6.2, Paragraph 2, Item 2 above,
      then, automatically, each Management Daemon MUST encrypt as well,
      since it has to do so in order to gain access.

   *  The SHALL in Section 6.2, Paragraph 2, Item 3 above applies to
      traffic from the global Internet.  An Attachment Daemon MAY accept
      unencrypted commands from localhost if the local installation's
      security practices allow it, for example, in a dedicated
      appliance.

   Firewalls SHOULD be used to restrict the communication between the
   Attachment Daemon and the accepted Management Daemons, prohibiting
   and discarding traffic from any systems that are not part of the
   envisioned power management setup.  Note: See Section 6.2, Paragraph
   4, Item 1 above on the use of SHOULD.

6.2.1.  Certificate Security

   In long-lived installations, such as those found in UPS management,
   careful certificate management is essential, whether the certificate
   is provided by a Certificate Authority or is a self-signed
   certificate.  For example, the expiration times of both the
   certificate containing the public key and the signing certificate
   should be specified.

6.3.  Attacks and Defenses

6.3.1.  Eavesdropping

   The defense against eavesdropping is encryption of the commands and
   responses passed between the client Management Daemon and server
   Attachment Daemon.  The protocol provides command STARTTLS, see
   Section 4.2.12, which calls on the Attachment Daemon to support TLS
   encryption of the communication.  If this command is accepted, the
   Management Daemon also encrypts.

   In current NUT Project practice, the use of TLS is optional; however,
   a Management Daemon may refuse to accept unencrypted communication.
   This is done by setting declarations FORCESSL to 1 and CERTVERIFY to
   1 in the Management Daemon configuration file.

6.3.1.1.  Misplaced Declarations Requiring TLS

   A further weakness is that the FORCESSL and CERTVERIFY declarations,
   which enforce use of encryption, are in the client Management Daemon
   configuration file and not in the Attachment Daemon.  Secure practice
   requires enforcement by the server Attachment Daemon, rather than a
   possibly rogue client Management Daemon out on the Internet.

   This weakness may be mitigated with strict firewall rules that would
   prevent the rogue client Management Daemon from accessing the
   Attachment Daemon.

6.3.1.2.  Weak Protection in Previous Version 2.7.4

   Although version 2.8.0 of NUT supports TLS 1.3 [RFC8446] with X.509
   v3 certificates as defined by [RFC5280], previous version 2.7.4 only
   supported earlier SSL/TLS versions.  To overcome this weakness, The
   following techniques have been used:

   *  Shims; see Appendix D.1

   *  TLS tunnel; see Appendix D.2

   *  Virtual Private Network (VPN); see Appendix D.3

   *  Virtual Local Area Network (VLAN); see Appendix D.4

6.3.2.  Man-in-the-Middle

   The protocol relies on TLS encryption to prevent man-in-the-middle
   attacks.  See Appendix D for defense methods used for previous NUT
   version 2.7.4.

6.3.3.  Masquerade Attack: Agent Verification

   The protocol allows a malicious client acting as a Management Daemon
   to send command FSD to an Attachment Daemon to shut down a working
   system and its power supply, as described in The Shutdown Story
   section (see Appendix B).  Similarly, a malicious client could turn
   off the UPS power outlets, causing the system to fail.

   The protocol provides commands USERNAME (see Section 4.2.13) and
   PASSWORD (see Section 4.2.8), which allow an administrative user in a
   Management Daemon to authenticate itself to the Attachment Daemon, as
   a defense against masquerade attacks.  The administrative username
   and password need protection against local malicious users.  This is
   done by restricting access to the configuration files.

6.3.4.  Message Insertion, Deletion, and Modification

   The protocol relies on TLS encryption to prevent message insertion,
   deletion, and modification attacks.  See Appendix D for defense
   methods used for previous NUT version 2.7.4.

6.3.5.  Replay

   There are two cases:

   1.  The replay is from a system other than an approved Management
       Daemon, i.e., the protocol relies on a firewall to block the
       traffic.

   2.  The replay is from an approved Management Daemon. i.e., the
       protocol relies on the Management Daemon's own security to
       prevent unauthorized access.

6.3.6.  Denial of Service

   The protocol relies on a very tightly specified firewall to prevent
   denial-of-service attacks.  Only designated client Management Daemons
   should be able to reach the server Attachment Daemon.

7.  IANA Considerations

   The protocol specified by this text runs over port 3493/TCP (nut),
   which is registered by the Network UPS Tools (NUT) Project.

   This document has been added to the registration's Reference field in
   the "Service Name and Transport Protocol Port Number Registry"
   [Registry].

8.  Implementation Status

   This section presents a very short summary of the status of the
   Network UPS Tools project.

   *  May 1996: The first hack as a cron job.
   *  September 1997: The first server-client code.
   *  March 1998: First public release.
   *  June 1999: Code rewrite with a UPS Driver smartups, an Attachment
      Daemon upsd, and a simple Management Daemon.
   *  September 1999: The project became "Network UPS Tools".  The
      Management Daemon upsmon supported Primary/Secondary
      configurations.
   *  June 2001: Common core for multiple Drivers.
   *  May 2002: IANA granted port 3493/TCP (nut).  August: release
      1.0.0.  November: OpenSSL support.
   *  April 2003: The initial set of command and variable names was
      designed.
   *  February 2005: Arnaud Quette took over the project lead from
      Russell Kroll.
   *  March 2016: Version 2.7.4 released, supported over 100 device
      manufacturers and hundreds of UPS models.
   *  November 2020: Evgeny "Jim" Klimov took over project lead from
      Arnaud Quette.
   *  May 2022: Version 2.8.0 released, supporting protocol version 1.3.

   See [githist] and Appendix J [History] for a detailed history of the
   NUT Project.

8.1.  Inclusion in Software Distributions

   The programs upsd, upsmon, upssched, upsc, upscmd, and upsrw have
   been included in the package known as "nut" in the package systems of
   many distributions, i.e., all the major Linux distributions and Unix
   distributions, such as OpenBSD and OpenSolaris.  A Microsoft Windows
   version has been developed but was not maintained.

8.2.  Recommended Minimum Support

   The features provided by current UPS units vary widely.  However,
   experience shows that a minimum feature set is needed for
   satisfactory use of the NUT Project software.  A full list of
   variables is available in source code file docs/nut-names.txt
   [gitvars], which serves as the Recording Document.

8.2.1.  Desktop PC Variables

   The following variables form a minimum set suitable for a desktop PC.
   It is expected that, on public power supply failure, the PC will be
   halted.  It will not restart automatically when power returns.

   *  battery.charge

   *  battery.charge.low

   *  device.mfr

   *  device.model

   *  ups.status with the minimum status symbol set OL OB LB FSD; see
      Section 5.1

8.2.2.  Unattended Servers and Additional Variables

   The following additional variables are needed in a minimum set
   suitable for an unattended server.  It is expected that, on public
   power supply failure, the server will be halted.  It will restart
   automatically when power returns.

   *  battery.date

   *  device.serial

   *  ups.delay.shutdown

   *  ups.delay.start

8.2.3.  Commands and Other Technical Terms

   Satisfactory use of the NUT Project software requires support for all
   the commands specified in protocol version 1.3, software version
   2.8.0.

8.2.4.  Support for Earlier Versions

   In order to ease migration from software version 2.7.4, which
   supported protocol version 1.2, software version 2.8.0 also supports
   the technical terms used in protocol version 1.2.  See Appendix C for
   the differences.

9.  References

9.1.  Normative References

   [RFC0020]  Cerf, V., "ASCII format for network interchange", STD 80,
              RFC 20, DOI 10.17487/RFC0020, October 1969,
              <https://www.rfc-editor.org/info/rfc20>.

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC5234]  Crocker, D., Ed. and P. Overell, "Augmented BNF for Syntax
              Specifications: ABNF", STD 68, RFC 5234,
              DOI 10.17487/RFC5234, January 2008,
              <https://www.rfc-editor.org/info/rfc5234>.

   [RFC7405]  Kyzivat, P., "Case-Sensitive String Support in ABNF",
              RFC 7405, DOI 10.17487/RFC7405, December 2014,
              <https://www.rfc-editor.org/info/rfc7405>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
              2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
              May 2017, <https://www.rfc-editor.org/info/rfc8174>.

9.2.  Informative References

   [C2ndEd]   Kernighan, B. and D. Ritchie, "The C Programming
              Language", 2nd edition, Prentice Hall Software Series,
              ISBN 0-13-110362-8, 1988.

   [devguide] Kroll, R., Quette, A., Lepple, C., and P. Selinger,
              "Network UPS Tools Project Developer Guide",
              <https://networkupstools.org/docs/developer-guide.chunked/
              ar01s09.html>.

   [Documentation]
              "Network UPS Tools Documentation",
              <https://networkupstools.org/documentation.html>.

   [githist]  "The Network UPS Tools repository, project history", July
              2022,
              <https://github.com/networkupstools/nut/blob/master/docs/
              history.txt>.

   [gitvars]  "The Network UPS Tools repository, variable names", April
              2022,
              <https://github.com/networkupstools/nut/blob/master/docs/
              nut-names.txt>.

   [History]  Kroll, R., Quette, A., and A. de Korte, "Network UPS Tools
              User Manual", May 2022,
              <https://networkupstools.org/docs/user-manual.pdf>.

   [HyTimeA]  ISO/IEC, "Information technology -- Hypermedia/Time-based
              Structuring Language (HyTime)", ISO/IEC 10744:1997, August
              1997.

   [IEC62351-1]
              IEC, "Power systems management and associated information
              exchange -- Data and communications security.  Part 1:
              Communication network and system security -- Introduction
              to security issues", 35 pages, TC 57 - Power systems
              management and associated information exchange, IEC TS
              62351-1:2007, May 2007, <https://nanopdf.com/download/
              technical-iec-specification-ts-62351-1_pdf>.

   [Library]  "Devices Dumps Library",
              <https://networkupstools.org/ddl/>.

   [NUT]      "Network UPS Tools, Devices Dumps Library",
              <https://www.networkupstools.org>.

   [nut-repository]
              "The Network UPS Tools repository",
              <https://github.com/networkupstools/nut/>.

   [nut-upsdev]
              NUT, "Network UPS Tools (NUT) Project Mailing List for
              Developers", <https://alioth-lists.debian.net/cgi-
              bin/mailman/listinfo/nut-upsdev>.

   [nut-upsuser]
              NUT, "Network UPS Tools (NUT) Project Mailing List for
              Users", <https://alioth-lists.debian.net/cgi-
              bin/mailman/listinfo/nut-upsuser>.

   [Registry] IANA, "Service Name and Transport Protocol Port Number
              Registry", <https://www.iana.org/assignments/service-
              names-port-numbers/service-names-port-numbers.xhtml>.

   [RFC3552]  Rescorla, E. and B. Korver, "Guidelines for Writing RFC
              Text on Security Considerations", BCP 72, RFC 3552,
              DOI 10.17487/RFC3552, July 2003,
              <https://www.rfc-editor.org/info/rfc3552>.

   [RFC5280]  Cooper, D., Santesson, S., Farrell, S., Boeyen, S.,
              Housley, R., and W. Polk, "Internet X.509 Public Key
              Infrastructure Certificate and Certificate Revocation List
              (CRL) Profile", RFC 5280, DOI 10.17487/RFC5280, May 2008,
              <https://www.rfc-editor.org/info/rfc5280>.

   [RFC7030]  Pritikin, M., Ed., Yee, P., Ed., and D. Harkins, Ed.,
              "Enrollment over Secure Transport", RFC 7030,
              DOI 10.17487/RFC7030, October 2013,
              <https://www.rfc-editor.org/info/rfc7030>.

   [RFC7991]  Hoffman, P., "The "xml2rfc" Version 3 Vocabulary",
              RFC 7991, DOI 10.17487/RFC7991, December 2016,
              <https://www.rfc-editor.org/info/rfc7991>.

   [RFC8446]  Rescorla, E., "The Transport Layer Security (TLS) Protocol
              Version 1.3", RFC 8446, DOI 10.17487/RFC8446, August 2018,
              <https://www.rfc-editor.org/info/rfc8446>.

   [RFC8894]  Gutmann, P., "Simple Certificate Enrolment Protocol",
              RFC 8894, DOI 10.17487/RFC8894, September 2020,
              <https://www.rfc-editor.org/info/rfc8894>.

   [SGML]     Goldfarb, C., "The SGML Handbook", Oxford University
              Press, ISBN-10 0-19-853737-9, 1990.

   [sgmlnorm] OpenJade Project, "OpenJade Distribution Page",
              <http://openjade.sourceforge.net/>.

   [stunnel]  "Stunnel", <https://www.stunnel.org/>.

Appendix A.  Variables

   The UPS variables represent the abstracted state of the UPS unit.
   Certain variables represent not only the state of some hardware
   feature but also provide tunable values and Instant Commands; see
   Section 2.5.  The full set of variables is recorded in the reference
   document for variable names [gitvars].

   The number of variables used in a given deployment depends on the
   sophistication of the UPS product; this annex shows a typical example
   of the subset of variables used for a reasonably complete "consumer
   grade" UPS.  The NUT Project maintains a large library of the
   variable subsets [Library] used by different UPS models.

   Note that successive versions of a given product may add or delete
   features, causing a change in the subset of variables used.  An
   example is the removal of ups.delay.start from a "consumer grade"
   UPS.  The manufacturer reserves the feature for the "professional"
   product.

   An implementation of a Management Daemon acting as a utility program
   may provide a listing of the variables available for a given product,
   for example, utility program upsc, as included in the NUT package;
   see Section 2.6, Paragraph 3.

   The following sections illustrate the use of variables by taking the
   values associated with a typical product.  The example is a 1600 Va
   1000 W UPS.

A.1.  Typical UPS Variables

    +===============================+============+====================+
    |            Variable           |  Typical   |      Default       |
    |                               |   Value    |    Description     |
    +===============================+============+====================+
    | battery.charge                | 100        | "Battery charge    |
    |                               |            | (percent of full)" |
    +-------------------------------+------------+--------------------+
    | battery.charge.low            | 20         | "Remaining battery |
    |                               |            | level when UPS     |
    |                               |            | switches to LB     |
    |                               |            | (percent)"         |
    +-------------------------------+------------+--------------------+
    | battery.runtime               | 1481       | "Battery runtime   |
    |                               |            | (seconds)"         |
    +-------------------------------+------------+--------------------+
    | battery.type                  | PbAc       | "Battery           |
    |                               |            | chemistry"         |
    +-------------------------------+------------+--------------------+
    | device.mfr                    | Example    | ""                 |
    |                               | Mfg        |                    |
    +-------------------------------+------------+--------------------+
    | device.model                  | Economy    | ""                 |
    |                               | 1600       |                    |
    +-------------------------------+------------+--------------------+
    | device.serial                 | 1234567890 | ""                 |
    +-------------------------------+------------+--------------------+
    | device.type                   | ups        | ""                 |
    +-------------------------------+------------+--------------------+
    | driver.name                   | usbhid-ups | "Driver name"      |
    +-------------------------------+------------+--------------------+
    | driver.parameter.lowbatt      | 37         | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.offdelay     | 30         | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.ondelay      | 40         | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.pollfreq     | 30         | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.pollinterval | 2          | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.port         | auto       | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.synchronous  | no         | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.parameter.vendorid     | 0999       | "Driver parameter: |
    |                               |            | <name>"            |
    +-------------------------------+------------+--------------------+
    | driver.version                | 2.8.0      | "Driver version -  |
    |                               |            | NUT release"       |
    +-------------------------------+------------+--------------------+
    | driver.version.data           | HID 1.39   | ""                 |
    +-------------------------------+------------+--------------------+
    | driver.version.internal       | 0.41       | "Internal driver   |
    |                               |            | version"           |
    +-------------------------------+------------+--------------------+
    | input.transfer.high           | 264        | "High voltage      |
    |                               |            | transfer point     |
    |                               |            | (V)"               |
    +-------------------------------+------------+--------------------+
    | input.transfer.low            | 184        | "Low voltage       |
    |                               |            | transfer point     |
    |                               |            | (V)"               |
    +-------------------------------+------------+--------------------+
    | outlet.1.desc                 | PowerShare | "Outlet            |
    |                               | Outlet 1   | description"       |
    +-------------------------------+------------+--------------------+
    | outlet.1.id                   | 2          | "Outlet system     |
    |                               |            | identifier"        |
    +-------------------------------+------------+--------------------+
    | outlet.1.status               | on         | "Outlet switch     |
    |                               |            | status"            |
    +-------------------------------+------------+--------------------+
    | outlet.1.switchable           | no         | "Outlet switch     |
    |                               |            | ability"           |
    +-------------------------------+------------+--------------------+
    | outlet.2.desc                 | PowerShare | "Outlet            |
    |                               | Outlet 2   | description"       |
    +-------------------------------+------------+--------------------+
    | outlet.2.id                   | 3          | "Outlet system     |
    |                               |            | identifier"        |
    +-------------------------------+------------+--------------------+
    | outlet.2.status               | on         | "Outlet switch     |
    |                               |            | status"            |
    +-------------------------------+------------+--------------------+
    | outlet.2.switchable           | no         | "Outlet switch     |
    |                               |            | ability"           |
    +-------------------------------+------------+--------------------+
    | outlet.desc                   | Main       | "Outlet            |
    |                               | Outlet     | description"       |
    +-------------------------------+------------+--------------------+
    | outlet.id                     | 1          | "Outlet system     |
    |                               |            | identifier"        |
    +-------------------------------+------------+--------------------+
    | outlet.power                  | 25         | ""                 |
    +-------------------------------+------------+--------------------+
    | outlet.switchable             | no         | "Outlet switch     |
    |                               |            | ability"           |
    +-------------------------------+------------+--------------------+
    | output.frequency.nominal      | 50         | "Nominal output    |
    |                               |            | frequency (Hz)"    |
    +-------------------------------+------------+--------------------+
    | output.voltage                | 230.0      | "Output voltage    |
    |                               |            | (V)"               |
    +-------------------------------+------------+--------------------+
    | output.voltage.nominal        | 230        | "Nominal output    |
    |                               |            | voltage (V)"       |
    +-------------------------------+------------+--------------------+
    | ups.beeper.status             | enabled    | "UPS beeper        |
    |                               |            | status"            |
    +-------------------------------+------------+--------------------+
    | ups.delay.shutdown            | 20         | "Interval to wait  |
    |                               |            | after shutdown     |
    |                               |            | with delay command |
    |                               |            | (seconds)"         |
    +-------------------------------+------------+--------------------+
    | ups.delay.start               | 30         | "Interval to wait  |
    |                               |            | before             |
    |                               |            | (re)starting the   |
    |                               |            | load (seconds)"    |
    +-------------------------------+------------+--------------------+
    | ups.firmware                  | 02         | "UPS firmware"     |
    +-------------------------------+------------+--------------------+
    | ups.load                      | 20         | "Load on UPS       |
    |                               |            | (percent of full)" |
    +-------------------------------+------------+--------------------+
    | ups.mfr                       | Example    | "UPS manufacturer" |
    |                               | Mfg        |                    |
    +-------------------------------+------------+--------------------+
    | ups.model                     | Economy    | "UPS model"        |
    |                               | 1600       |                    |
    +-------------------------------+------------+--------------------+
    | ups.power.nominal             | 1600       | "UPS power rating  |
    |                               |            | (VA)"              |
    +-------------------------------+------------+--------------------+
    | ups.productid                 | ffff       | "Product ID for    |
    |                               |            | USB devices"       |
    +-------------------------------+------------+--------------------+
    | ups.serial                    | 000000000  | "UPS serial        |
    |                               |            | number"            |
    +-------------------------------+------------+--------------------+
    | ups.status                    | OL         | "UPS status"       |
    +-------------------------------+------------+--------------------+
    | ups.temperature               | 27         | "UPS temperature   |
    |                               |            | (C)"               |
    +-------------------------------+------------+--------------------+
    | ups.timer.shutdown            | 0          | "Time before the   |
    |                               |            | load will be       |
    |                               |            | shutdown           |
    |                               |            | (seconds)"         |
    +-------------------------------+------------+--------------------+
    | ups.timer.start               | 0          | "Time before the   |
    |                               |            | load will be       |
    |                               |            | started (seconds)" |
    +-------------------------------+------------+--------------------+
    | ups.vendorid                  | 0999       | "Vendor ID for USB |
    |                               |            | devices"           |
    +-------------------------------+------------+--------------------+

                       Table 6: Typical UPS Variables

A.2.  Typical UPS Readable and Writable Variables

   Some of the features of a UPS are represented by variables that may
   be tuned by the user.  The following variables are typical of such
   tunable features.  The precise list depends on the model of UPS.  An
   implementation of a Management Daemon acting as a utility program may
   provide a listing of the variables available, as well as acting on
   them, for example, utility program upsrw, as included in the NUT
   package; see Section 2.6, Paragraph 3.

     +========================+============+=========================+
     |        Variable        |  Typical   |   Default Description   |
     |                        |   Value    | Provided as Response to |
     |                        |            |   the Command GET DESC  |
     +========================+============+=========================+
     | battery.charge.low     | 20         | "Remaining battery      |
     |                        |            | level when UPS switches |
     |                        |            | to LB (percent)"        |
     +------------------------+------------+-------------------------+
     | input.transfer.high    | 264        | "High voltage transfer  |
     |                        |            | point (V)"              |
     +------------------------+------------+-------------------------+
     | input.transfer.low     | 184        | "Low voltage transfer   |
     |                        |            | point (V)"              |
     +------------------------+------------+-------------------------+
     | outlet.1.desc          | PowerShare | "Outlet description"    |
     |                        | Outlet 1   |                         |
     +------------------------+------------+-------------------------+
     | outlet.2.desc          | PowerShare | "Outlet description"    |
     |                        | Outlet 2   |                         |
     +------------------------+------------+-------------------------+
     | outlet.2.switchable    | no         | "Outlet switch ability" |
     +------------------------+------------+-------------------------+
     | outlet.desc            | Main       | "Outlet description"    |
     |                        | Outlet     |                         |
     +------------------------+------------+-------------------------+
     | outlet.power           | 25         | "Description            |
     |                        |            | unavailable"            |
     +------------------------+------------+-------------------------+
     | output.voltage.nominal | 230        | "Nominal output voltage |
     |                        |            | (V)"                    |
     +------------------------+------------+-------------------------+
     | ups.delay.shutdown     | 20         | "Interval to wait after |
     |                        |            | shutdown with delay     |
     |                        |            | command (seconds)"      |
     +------------------------+------------+-------------------------+
     | ups.delay.start        | 30         | "Interval to wait       |
     |                        |            | before (re)starting the |
     |                        |            | load (seconds)"         |
     +------------------------+------------+-------------------------+

            Table 7: Typical Readable and Writable UPS Variables

A.3.  Typical UPS Instant Commands

   Some of the features of a UPS are actions known as Instant Commands
   (see Section 2.5), which may be ordered by the user.  The following
   variables represent such Instant Commands.  The precise list depends
   on the model of UPS.  An implementation of a Management Daemon acting
   as a utility program may provide a listing of the variables
   available, as well as acting on them, for example, utility program
   upscmd, as included in the NUT package; see Section 2.6, Paragraph 3.

      +==================+==========================================+
      |     Command      |                 Meaning                  |
      +==================+==========================================+
      | beeper.disable   | Disable the UPS beeper                   |
      +------------------+------------------------------------------+
      | beeper.enable    | Enable the UPS beeper                    |
      +------------------+------------------------------------------+
      | beeper.mute      | Temporarily mute the UPS beeper          |
      +------------------+------------------------------------------+
      | load.off         | Turn off the load immediately            |
      +------------------+------------------------------------------+
      | load.off.delay   | Turn off the load with a delay (seconds) |
      +------------------+------------------------------------------+
      | load.on          | Turn on the load immediately             |
      +------------------+------------------------------------------+
      | load.on.delay    | Turn on the load with a delay (seconds)  |
      +------------------+------------------------------------------+
      | shutdown.return  | Turn off the load and return when power  |
      |                  | is back                                  |
      +------------------+------------------------------------------+
      | shutdown.stayoff | Turn off the load and remain off         |
      +------------------+------------------------------------------+
      | shutdown.stop    | Stop a shutdown in progress              |
      +------------------+------------------------------------------+

                     Table 8: Typical Instant Commands

Appendix B.  The Shutdown Story for System and UPS

   This appendix provides background material helpful for a general
   understanding of the relation between system and UPS.  It does not
   define any feature of the command-response protocol.

   We consider the steps involved in the shutdown and restart of a long-
   running unattended server protected by a single UPS.  The Management
   Daemon runs in the server as shown in Figure 8.

                     ,------------------SERVER------------------,
                     |                    |                     |
           ,-----,   |     UPS       <-Commands        UPS      |
           | UPS |---|  Attachment        |         Management  |
           |     |===|    Daemon       Responses->    Daemon    |
           /-----\   '--------------------'---------------------'
                                       Internal
                                       loopback

                  Figure 8: Long-Running Unattended Server

   1.   _The public power supply is on._ The system runs normally.
        Every 5 seconds, variable ups.status reports OL. _Days, weeks,
        months go by..._

   2.   _Winter storm.  Tree falls on power lines.  The public power
        supply fails._ The server remains operational, running on the
        UPS battery.  The Management Daemon polls the Attachment Daemon
        and detects status change OL->OB.

   3.   The Management Daemon logs warning messages.  The server is
        still operational, running on the UPS battery. _Minutes go
        by..._

   4.   The battery discharges below the level specified by variable
        battery.charge.low.  The server remains operational, but the UPS
        battery will not last much longer.  The Management Daemon polls
        the Attachment Daemon and detects status change OB->OB+LB.

   5.   The Management Daemon logs the low battery event.

   6.   The Management Daemon decides to call for a system shutdown.  It
        sets status FSD in the Attachment Daemon to call on any
        Secondaries to shut down and waits for command GET NUMATTACH to
        report one single attachment, i.e., the Primary itself.  The
        Management Daemon then issues the system shutdown command for
        itself.

   7.   The operating system's shutdown process takes over.  During the
        system shutdown, a specific script to the NUT Project or an
        equivalent system service unit runs the command upsdrvctl
        shutdown.  This tells the UPS that it is to shut down N seconds
        later where the default is N=20.  Note that the "shutdown" of a
        UPS removes power from the outlet sockets but may not turn the
        UPS off completely.  A delayed shutdown is sometimes audible,
        and the characteristic beeping of the UPS stops.

   8.   The system shuts down and powers down, hopefully before the N=20
        seconds have passed.

   9.   _N seconds after item 7_ The UPS shuts down, i.e., it turns off
        its outlet sockets when N=20 seconds have passed.  With some UPS
        units, there is an audible "clunk".

        What if the public power supply returns before the UPS shuts
        down?  The UPS unit should be able to wait a configurable time
        with default 30 seconds.  These two timers start from the moment
        the UPS receives the upsdrvctl shutdown command. _Minutes,
        hours, days go by..._

   10.  _Some time later, maybe much later, the public power supply
        returns._ The UPS reconnects its outlets to send power to the
        protected system.

   11.  The system BIOS option "Restore power on AC return" or "Restore
        to previous state" has hopefully been selected and the system
        powers up.  The bootstrap process of the operating system
        begins.

   12.  The operating system starts the Attachment Daemon and the
        Management Daemon.  The Attachment Daemon starts the Driver and
        scans the UPS.  The UPS status becomes OL+LB.

   13.  After some time, the battery charges above the
        battery.charge.low threshold, and the Attachment Daemon declares
        the status change OL+LB->OL.  We are now back in the same
        situation as item 1 above.

Appendix C.  Technical Terms: Historical Differences

   This appendix lists the major differences between the technical terms
   used in NUT software release 2.8.0 and documented in this text, as
   well as those used in previous version 2.7.4 of the NUT Project.

        +===================+========================+===========+
        | Term in Previous  | Term in this Document, | Reference |
        | Release NUT 2.7.4 | Release NUT 2.8.0      |           |
        +===================+========================+===========+
        | ALREADY-LOGGED-IN | ALREADY-ATTACHED       | Table 3   |
        +-------------------+------------------------+-----------+
        | ALREADY-SSL-MODE  | TLS-ALREADY-ENABLED    | Table 3   |
        +-------------------+------------------------+-----------+
        | LOGIN             | ATTACH                 | Section   |
        |                   |                        | 4.2.1     |
        +-------------------+------------------------+-----------+
        | LOGOUT            | DETACH                 | Section   |
        |                   |                        | 4.2.2     |
        +-------------------+------------------------+-----------+
        | Master            | Primary                | Section   |
        |                   |                        | 2.7       |
        +-------------------+------------------------+-----------+
        | NETVER            | PROTVER                | Section   |
        |                   |                        | 4.2.10    |
        +-------------------+------------------------+-----------+
        | NUMLOGINS         | NUMATTACH              | Section   |
        |                   |                        | 4.2.4.3   |
        +-------------------+------------------------+-----------+
        | Slave             | Secondary              | Section   |
        |                   |                        | 2.8       |
        +-------------------+------------------------+-----------+

             Table 9: Technical Terms: Historical Differences

Appendix D.  Security Defenses in Release 2.7.4

   Previous NUT version 2.7.4 did not provide support for TLS 1.3
   [RFC8446].  The following subsections describe mitigating techniques.

D.1.  Shims

   Previous version 2.7.4 of NUT did not support TLS 1.3 [RFC8446].
   Where such protection is needed for version 2.7.4, a possible
   technique introduces shims between the Attachment Daemon and the
   network and between the network and the Management Daemon, as shown
   in Figure 9.  These shims provide TLS 1.3 support, thus allowing the
   Attachment Daemon and Management Daemon to continue temporarily
   without having TLS implementations themselves.  The technique has
   been successfully tested.

                      TLS shim listens     TLS shim listens
                      on port TBD1/TCP     on port 3493/TCP
       ,-----,------------,----,               ,----,--------------,
       | UPS - Attachment |TLS | <-STARTTLS    | TLS|  Management  |
       |     |   Daemon   |shim|         OK--> |shim|    Daemon    |
       /-----'------------'----\               '----'--------------'
               Listens on
             port 3493/TCP

            Figure 9: Shims Provide TLS Support During Migration

D.1.1.  Attachment Daemon Shim

   The shim in front of the Attachment Daemon listens to incoming
   traffic on port TBD1/TCP.  When it receives the command STARTTLS, it:

   1.  returns OK to the client and sets up TLS encapsulation.
   2.  does not send STARTTLS to the Attachment Daemon port 3493/TCP.

   All other commands and responses are passed through.

   Note: Port TBD1/TCP is not specified by this text.

D.1.2.  Management Daemon Shim

   The shim in front of the Management Daemon listens for incoming
   traffic on port 3493/TCP.  When it receives the command STARTTLS, it:

   1.  returns FEATURE-NOT-CONFIGURED to the client.
   2.  sends STARTTLS to the Attachment Daemon on port TBD1/TCP.

   All other commands and responses are passed through.

D.2.  TLS Tunnels

   Another technique is the use of TLS tunnels [RFC8446], using a
   software, such as stunnel [stunnel], which adds OpenSSL-based TLS
   support without modifying the Attachment Daemon or Management Daemon.
   The NUT Project has no procedure to enforce this on sites.

D.3.  VPN

   A further option to secure communications is very similar to TLS
   tunneling [RFC8446] and consists of routing the NUT traffic through a
   Virtual Private Network (VPN).

D.4.  VLAN

   A fourth option is to isolate the UPS management traffic at the
   network switching level using a Virtual LAN (VLAN) technique.

                    ,-------------,               ,-------------,
          ,-----,   | Attachment  |               | Management  |
          | UPS |---|   Daemon    |               |   Daemon    |
          |     |   |-------------|      UPS      |-------------|
          |     |===|             |   Management  |    UPS      |
          /-----\   | Protected   |~~~~~~~~~~~~~~~| Management  |
                    |  Server     |     VLAN      |   Client    |
                    |             |               '-------------'
                    '-------------'
                Production | VLAN
                       ,---|-------,
                      ,-----------,|
                     ,-----------,|'
                     |  Clients  |'
                     '-----------'

         Figure 10: UPS Management Protocol Runs over Its Own VLAN

   In Figure 10, there are two VLANS: the main traffic between the
   protected server and its clients using the production VLAN.  The UPS
   management traffic between the Attachment and Management Daemons uses
   the UPS management VLAN marked as ~~~~~~~~~~~~~.

Appendix E.  Administrative Security

   Administrative commands, such as FSD, INSTCMD, and SET, are powerful
   and can have a deep effect on system integrity.  For example, the
   command FSD is involved in mission-critical system shutdown
   decisions.  Access to them needs to be managed and restricted.  This
   section presents the current practice.

E.1.  Management of Administrative Users

   The Attachment Daemon maintains a file (currently upsd.users) that
   defines each administrative user.  Note that these users are
   independent of those recorded in file /etc/passwd.  Each
   administrative user gets its own section in file upsd.users.  The
   declarations in that section set the parameters that define that
   user's privileges.  The section begins with the name of the user
   enclosed in square brackets, opening bracket ([) and closing bracket
   (]), and continues until the next username in brackets or EOF.

   For example, the following file declares two administrative users,
   admin and pfy:

      [admin]
          password = sekret
          upsmon master
          actions = SET
          instcmds = ALL
      [pfy]
          password = sekret
          instcmds = test.panel.start
          instcmds = test.panel.stop

   Within each section, the administrative user declarations are:

        +=============+==========================================+
        | Declaration |                 Meaning                  |
        +=============+==========================================+
        | actions     | Allow the user to do certain things in   |
        |             | the Attachment Daemon.  To specify       |
        |             | multiple actions, use multiple instances |
        |             | of the declaration.  Valid actions are:  |
        |             |                                          |
        |             | *  FSD Set the "Forced Shutdown" flag    |
        |             |    for this UPS.  See Section 4.2.3.     |
        |             |                                          |
        |             | *  SET Change the value of a UPS         |
        |             |    variable.  See Section 4.2.11.        |
        +-------------+------------------------------------------+
        | instcmds    | Let a user initiate specific Instant     |
        |             | Commands.  See Section 4.2.6.  Use value |
        |             | ALL to grant all commands automatically. |
        |             | To specify multiple commands, use        |
        |             | multiple instances of the instcmds       |
        |             | field.  For the full list of what a      |
        |             | given UPS supports, use client upscmd -l |
        |             | supplied by the NUT Project.  The LIST   |
        |             | CMD command is issued within the client  |
        |             | upscmd.                                  |
        +-------------+------------------------------------------+
        | password    | Set the password for this user.  _Your   |
        |             | password should be more secure than the  |
        |             | examples shown._                         |
        +-------------+------------------------------------------+
        | upsmon      | Add the necessary actions for a          |
        |             | Management Daemon to process a system    |
        |             | shutdown.  In current practice, the      |
        |             | value is still master or slave.  Note    |
        |             | that there is no EQUALS =.               |
        +-------------+------------------------------------------+

                Table 10: Administrative User Declarations

E.2.  An Administrative User of a Client Management Daemon

   The following examples show the current security practices for
   administrative users of a client Management Daemon.  They also
   illustrate the command pair USERNAME and PASSWORD.  See Sections
   4.2.13 and 4.2.8.

E.2.1.  An Administrative User Logs into a Short Session

   In this simple example of current practice, the system administrator
   sets the battery level at which an Attachment Daemon will raise the
   status LB, represented by variable battery.charge.low, to 35% of full
   charge.  A system administrator types the following command to call
   the client upsrw supplied by the NUT Project.

   upsrw -s battery.charge.low=35 -u admin -p sekret UPS-1@example.com

   Option -s specifies the variable and the value, option -u specifies
   the USERNAME, option -p specifies the PASSWORD, and UPS-1@example.com
   is the UPS.  The USERNAME and PASSWORD commands are issued within the
   client upsrw, and the session is of short duration.

   Note: Your password should be stronger than the example shown.

E.2.2.  An Administrative User Logs into a Long Session

   In this second example of current practice, the long-running
   Management Daemon upsmon, which is responsible for initiating system
   shutdowns and which is provided by the NUT Project, issues commands
   USERNAME and PASSWORD when it starts up.  The data values needed for
   the USERNAME and PASSWORD commands are provided by a configuration
   file upsmon.conf, which contains the line:

   MONITOR UPS-1@example.com 1 admin sekret master

   This says that the UPS to be monitored is UPS-1@example.com.  It
   provides 1 single power supply.  The administrative user is admin
   with password sekret.  The Management Daemon acts as a Primary,
   although current practice still uses the former term master.

   The USERNAME and PASSWORD commands are contained within the client
   upsmon, and the session is of long duration.

Acknowledgments

   This document is based on the NUT Project documentation [devguide].
   The editor acknowledges the work of Charles Lepple, Arjen de Korte,
   Arnaud Quette, Jim Klimov, Russell Kroll, Manuel Wolfshant, Greg
   Troxel, Mark Hansen, and many others who contribute to the
   nut-upsuser [nut-upsuser] and nut-upsdev [nut-upsdev] mailing lists.

   Earlier draft versions of this document were prepared using an SGML
   DTD [SGML] and an XML meta-DTD defined by HyTime Annex A [HyTimeA].
   Unlike XML, SGML offers markup minimization, and the earlier drafts
   took advantage of this.  The osgmlnorm [sgmlnorm] program generated
   the XML that was used as input to xml2rfc [RFC7991], which then
   created the document's current source.  The editor acknowledges the
   help received from Carsten Bormann and Julian Reschke in the xml2rfc
   mailing list.

   Many helpful comments were received from Eliot Lear, Bart Smit, David
   Zomaya, Joyce Norris, and Ted Mittelstaedt.

Author's Address

   Roger Price (editor)
   Network UPS Tools Project
   France
   Email: ietf@rogerprice.org