diff options
author | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
---|---|---|
committer | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
commit | 4bfd864f10b68b71482b35c818559068ef8d5797 (patch) | |
tree | e3989f47a7994642eb325063d46e8f08ffa681dc /doc/rfc/rfc1694.txt | |
parent | ea76e11061bda059ae9f9ad130a9895cc85607db (diff) |
doc: Add RFC documents
Diffstat (limited to 'doc/rfc/rfc1694.txt')
-rw-r--r-- | doc/rfc/rfc1694.txt | 1963 |
1 files changed, 1963 insertions, 0 deletions
diff --git a/doc/rfc/rfc1694.txt b/doc/rfc/rfc1694.txt new file mode 100644 index 0000000..4e8d6e4 --- /dev/null +++ b/doc/rfc/rfc1694.txt @@ -0,0 +1,1963 @@ + + + + + + +Network Working Group T. Brown +Request for Comments: 1694 K. Tesink +Obsoletes: 1304 Editors +Category: Standards Track Bell Communications Research + August 1994 + + + Definitions of Managed Objects + for SMDS Interfaces using SMIv2 + +Status of this Memo + + This document specifies an Internet standards track protocol for the + Internet community, and requests discussion and suggestions for + improvements. Please refer to the current edition of the "Internet + Official Protocol Standards" (STD 1) for the standardization state + and status of this protocol. Distribution of this memo is unlimited. + +Abstract + + This memo defines a portion of the Management Information Base (MIB) + for use with network management protocols in TCP/IP-based internets. + In particular, it defines objects for managing objects for SMDS + access interfaces. This includes the following access protocols: + + SIP [13] + SIP/DXI [18] and [20] + SIP/FR [19] + SIP/ATM [24] + + This memo replaces RFC 1304 [12], and defines a MIB module which is + both compliant to the SNMPv2 SMI and semantically-identical to the + existing RFC 1304-based definitions. + + This memo also assumes application of the MIB II Interfaces group as + defined in [9]. + +Table of Contents + + 1. The SNMPv2 Network Management Framework ............... 2 + 2. Objects ............................................... 3 + 2.1 Format of Definitions ................................ 3 + 3. Overview .............................................. 4 + 3.1 SIP Level 3 .......................................... 5 + 4. Object Definitions .................................... 9 + 4.1 The SIP Level 3 Group ................................ 10 + 4.2 The SIP Level 2 Group ................................ 14 + 4.3 The SIP PLCP Group ................................... 17 + + + +Brown & Tesink [Page 1] + +RFC 1694 SMDS Interface Objects August 1994 + + + 4.3.1 The DS1 PLCP Group ................................. 17 + 4.3.2 The DS3 PLCP Group ................................. 19 + 4.4 The SMDS Applications Group .......................... 20 + 4.4.1 The IP over SMDS Group ............................. 21 + 4.5 The SMDS Carrier Selection Group ..................... 22 + 4.6 The SIP Error Log Group .............................. 23 + 4.7 The Data eXchange Interface Group .................... 27 + 4.8 Conformance Information .............................. 29 + 5. Acknowledgments ....................................... 32 + 6. References ............................................ 32 + 7. Security Considerations ............................... 34 + 8. Authors' Addresses .................................... 35 + +1. The SNMPv2 Network Management Framework + + The SNMPv2 Network Management Framework consists of four major + components. They are: + + o RFC 1442 [1] which defines the SMI, the mechanisms used for + describing and naming objects for the purpose of + management. + + o STD 17, RFC 1213 [6] defines MIB-II, the core set of managed + objects for the Internet suite of protocols. Reference [12] + defines the evolution of the Interfaces Group of MIB II in + terms of extensions and precise applications of the objects. + + o RFC 1445 [4] which defines the administrative and other + architectural aspects of the framework. + + o RFC 1448 [5] which defines the protocol used for network + access to managed objects. + + The Framework permits new objects to be defined for the purpose of + experimentation and evaluation. + + This specification makes also use of: + + o RFC 1443 [2] which defines textual conventions for the + specification of managed objects. + + o RFC 1444 [3] which defines conformance statements for the + specification of managed objects. + + + + + + + + +Brown & Tesink [Page 2] + +RFC 1694 SMDS Interface Objects August 1994 + + +2. Objects + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. Objects in the MIB are + defined using the subset of Abstract Syntax Notation One (ASN.1) [7] + defined in the SMI. In particular, each object has a name, a syntax, + and an encoding. The name is an object identifier, an + administratively assigned name, which specifies an object type. The + object type together with an object instance serves to uniquely + identify a specific instantiation of the object. For human + convenience, we often use a textual string, termed the OBJECT + DESCRIPTOR, to also refer to the object type. + + The syntax of an object type defines the abstract data structure + corresponding to that object type. The ASN.1 language is used for + this purpose. However, the SMI RFC 1442 purposely restricts the + ASN.1 constructs which may be used. These restrictions are + explicitly made for simplicity. + + The encoding of an object type is simply how that object type is + represented using the object type's syntax. Implicitly tied to the + notion of an object type's syntax and encoding is how the object type + is represented when being transmitted on the network. The SMI + specifies the use of the basic encoding rules of ASN.1 [8], subject + to the additional requirements imposed by the SNMP. + +2.1. Format of Definitions + + Section 4 contains contains the specification of all object types + contained in this MIB module. The object types are defined using the + conventions defined in the SMI, as amended by the extensions + specified in the SNMPv2 SMI. + + + + + + + + + + + + + + + + + + + +Brown & Tesink [Page 3] + +RFC 1694 SMDS Interface Objects August 1994 + + +3. Overview + + SMDS is a service that can be provided by numerous interface + protocols as shown in the following figure: + + +-------------------+ +-------------------+ + | SIP Level 3* [13] | | SIP Level 3* [13] | + +-------------------+ +-------------------+ + | SIP Level 2* [13] | | DXI Level 2* [20] | + +-------------------+ +-------------------+ + | SIP PLCP* [14] | | | + +-------------------+ | DXI Level 1 [20] | + | SIP Level 1 [14] | | | + +-------------------+ +-------------------+ + SIP based access DXI based access + + +-------------------+ +-------------------+ + | SIP Level 3* [13] | | SIP Level 3* [13] | + +-------------------+ +-------------------+ + | ATM [21] | | Frame Relay [19] | + +-------------------+ +-------------------+ + | ATM PLCP [21] | | | + +-------------------+ | Frame Relay [19] | + | ATM Level 1 [21] | | Level 1 | + +-------------------+ +-------------------+ + ATM based access FR based access + + + + + + + + + + + + + + + + + + + + + + + + + +Brown & Tesink [Page 4] + +RFC 1694 SMDS Interface Objects August 1994 + + + In the figure below, managed objects for the protocol levels marked + with a (*) are defined in this memo. Additional managed objects that + must be used to manage SMDS interfaces are defined in other MIB + modules as indicated in the figure. + + +-------------------+ +-------------------+ + | SIP Level 3* | | SIP Level 3* | + +-------------------+ +-------------------+ + | SIP Level 2* | | DXI Level 2* | + +-------------------+ +-------------------+ + | SIP PLCP* | | | + +-------------------+ | DXI Level 1 | + | SIP Level 1 | | | + | [10] or [11] | | [10] | + +-------------------+ +-------------------+ + SIP based access DXI based access + + +-------------------+ +-------------------+ + | SIP Level 3* | | SIP Level 3* | + +-------------------+ +-------------------+ + | ATM [22] | | Frame Relay [23] | + +-------------------+ +-------------------+ + | ATM PLCP/TC [22] | | | + +-------------------+ | Frame Relay | + | ATM Level 1 [10] | | Level 1 | + | [11], or [25] | | [10] or [11] | + +-------------------+ +-------------------+ + ATM based access FR based access + + With the improved interpretation of the MIB II interfaces group [9], + some objects can be represented by ifTable. This means that these + objects have been deprecated from the MIB module defined in RFC 1304, + and ifTable is used instead. No semantical changes have been made to + these objects. Only the object identifiers and object descriptors + have been changed to the objects defined in ifTable. + + Implementation experience has shown that the objects + sipL3UnrecognizedIndividualDAs and sipL3UnrecognizedGAs were not + supported. + +3.1. SIP Level 3 + + Objects for SIP Level 3 apply to all methods to access SMDS shown in + the figures above. With the improved interpretation of the MIB II + interfaces group, most objects can be represented by ifTable. The + appropriate mapping is defined below. + + + + + +Brown & Tesink [Page 5] + +RFC 1694 SMDS Interface Objects August 1994 + + + This document does not specify objects for the management of + subscription or configuration of Subscriber-Network Interfaces + (SNIs). Those objects are defined in Definitions of Managed Objects + for SMDS Subscription [17]. Bellcore requirements on these objects + are specified in TR-TSV-001062 [16]. + + ifTable Object Use for + ====================================================== + ifIndex Interface index. + + ifDescr Interface description. + For example, SIP Level 3 sublayer + of a SNI. + + ifType Set to 31. + + ifMtu Set to 9232. + + ifSpeed Peak bandwidth in bits per second available + for use as provided by the supporting Level + 2 protocol. For example, 1.17 Mbps when + using SIP based DS1 SNIs, and 1.536 Mbps + when using DXI-based DS1 DXI-SNI. + + ifPhysAddress OCTET STRING of Size 8. Value is + a 16-digit Binary Coded Decimal + SMDS address that is + assigned to this interface. + + ifAdminStatus The desired administrative status of the + SMDS interface. + + ifOperStatus The current operational status of the + SMDS interface. + + ifLastChange The elapsed time since the last + re-initialization of the interface. + The value of sysUpTime at the time the + interface entered its current + operational state. If the current + state was entered prior to the last + re-initialization of the local + network management subsystem, then + this object contains a zero value. + + ifInOctets Number of received octets at SIP Level 3. + For SIP based SNIs, this is the number of + sipL2ReceivedCounts multiplied by 44. + + + +Brown & Tesink [Page 6] + +RFC 1694 SMDS Interface Objects August 1994 + + + ifInUcastPkts The total number of individually addressed + SIP Level 3 PDUs received from the remote + system across the SNI. The total includes + only unerrored SIP Level 3 PDUs. + [identical to RFC1304: + sipL3ReceivedIndividualDAs] + + ifInDiscards The number of received SIP Level 3 PDUs + discarded. For SMDS interfaces, this + counter will always be zero. + + ifInErrors The total number of SIP Level 3 PDUs + received from the remote system that were + discovered to have errors (including + protocol processing and bit errors but + excluding addressing-related errors) and + were discarded. Includes both group + addressed SIP Level 3 PDUs and SIP Level + 3 PDUs containing an individual + destination address. + [identical to RFC1304: sipL3Errors] + + ifInUnknownProtos The number of SIP Level 3 PDUs received + from the remote system with a Source or + Destination Address_Type subfields, (the + four most significant bits of the 64 bit + address field), not equal to the value + 1100 or 1110. Also, an error is + considered to have occurred if the + Address_Type field for a Source Address + is equal to 1110 (a group address). + [identical to RFC1304: + sipL3InvalidSMDSAddressTypes] + + ifOutOctets Number of received octets for transmission + at SIP Level 3. For SIP based + SNIs, this is the number + of sipL2SentCounts multiplied by 44. + + ifOutUcastPkts The number of individually addressed SIP + Level 3 PDUs that have been sent by this + system across the interface. + [identical to RFC1304: + sipL3SentIndividualDAs] + + ifOutDiscards The number of SIP Level 3 PDUs discarded in + the egress direction. For SMDS interfaces, + this counter will always be zero. + + + +Brown & Tesink [Page 7] + +RFC 1694 SMDS Interface Objects August 1994 + + + ifOutErrors The number of SIP Level 3 PDUs + discarded in the egress + direction, because of errors. + For SMDS interfaces, this counter will + always be zero. + + ifName The textual name of the interface. + If not used, this variable contains + a zero-length string. + + ifInMulticastPkts The total number of group addressed SIP + Level 3 PDUs received from the remote + system across the interface. The total + includes only unerrored SIP Level 3 PDUs. + [identical to RFC1304: sipL3ReceivedGAs] + + ifInBroadcastPkts This variable is not applicable for SMDS + interfaces. Therefore, this counter is + always zero. + + ifOutMulticastPkts The number of group addressed SIP Level 3 + PDUs that have been sent by this system + across the interface. + [identical to RFC1304: sipL3SentGAs] + + ifOutBroadcastPkts This variable is not applicable for SMDS + interfaces. Therefore, this counter is + always zero. + + ifLinkUpDownTrapEnble The value of this object is + disabled(2) for SIP Level 3 interfaces. + + ifHighSpeed Set to the user data rate of the + interface in millions of bits per second. + If the user data rate is less than 1 Mbps, + then this value is zero. + + ifPromiscuousMode Set to false(2). + + ifConnectorPresent Set to false(2). + + Consult the Evolution of the Interfaces Group [9] for when to use the + HC (High Capacity) counters (e.g., ifHCInOctets is a 64-bit counter). + + + + + + + + +Brown & Tesink [Page 8] + +RFC 1694 SMDS Interface Objects August 1994 + + +4. Object Definitions + + SIP-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Counter32, + Integer32, IpAddress FROM SNMPv2-SMI + TimeStamp, TEXTUAL-CONVENTION FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF + transmission, ifIndex, mib-2 FROM RFC1213-MIB; + + -- This is the MIB module for the SMDS Interface objects. + + sipMIB MODULE-IDENTITY + LAST-UPDATED "9403311818Z" + ORGANIZATION "IETF Interfaces Working Group" + CONTACT-INFO + " Tracy Brown + Postal: Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + US + + Tel: +1 908 758-2107 + Fax: +1 908 758-4177 + E-mail: tacox@mail.bellcore.com + + Kaj Tesink + Postal: Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + US + + Tel: +1 908 758 5254 + Fax: +1 908 758 4177 + E-mail: kaj@cc.bellcore.com." + DESCRIPTION + "The MIB module to describe + SMDS interfaces objects." + ::= { mib-2 36 } + + SMDSAddress ::= TEXTUAL-CONVENTION + DISPLAY-HINT "1h:" + STATUS current + DESCRIPTION + "The 60-bit SMDS address, + + + +Brown & Tesink [Page 9] + +RFC 1694 SMDS Interface Objects August 1994 + + + preceded by 4 bits with the following values: + 1100 when representing an individual address + 1110 when representing a group address." + SYNTAX OCTET STRING (SIZE (8)) + + IfIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The value of this object identifies the + interface for which this entry contains + management information. The value of this + object for a particular interface has the same + value as the ifIndex object, defined in RFC + 1213, for the same interface." + SYNTAX Integer32 + + + sip OBJECT IDENTIFIER ::= { transmission 31 } + sipMIBObjects OBJECT IDENTIFIER ::= { sipMIB 1 } + + + -- The SIP Level 3 Group + + sipL3Table OBJECT-TYPE + SYNTAX SEQUENCE OF SipL3Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains SIP L3 parameters and + state variables, one entry per SIPL3 interface." + ::= { sip 1 } + + sipL3Entry OBJECT-TYPE + SYNTAX SipL3Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This list contains SIP L3 parameters and + state variables." + INDEX { sipL3Index } + ::= { sipL3Table 1 } + + SipL3Entry ::= SEQUENCE { + sipL3Index IfIndex, + sipL3ReceivedIndividualDAs Counter32, + sipL3ReceivedGAs Counter32, + sipL3UnrecognizedIndividualDAs Counter32, + sipL3UnrecognizedGAs Counter32, + + + +Brown & Tesink [Page 10] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipL3SentIndividualDAs Counter32, + sipL3SentGAs Counter32, + sipL3Errors Counter32, + sipL3InvalidSMDSAddressTypes Counter32, + sipL3VersionSupport Integer32 + } + + sipL3Index OBJECT-TYPE + SYNTAX IfIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object identifies the SIP + L3 interface for which this entry contains + management information. " + ::= { sipL3Entry 1 } + + sipL3ReceivedIndividualDAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifInUcastPkts defined in [9] must be used instead. + DESCRIPTION + "The total number of individually addressed SIP + Level 3 PDUs received from the remote system + across the SNI. The total includes only + unerrored L3PDUs." + ::= { sipL3Entry 2 } + + sipL3ReceivedGAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifInMulticastPkts defined in [9] must be used instead. + DESCRIPTION + "The total number of group addressed SIP Level 3 + PDUs received from the remote system across the + SNI. The total includes only unerrored L3PDUs." + ::= { sipL3Entry 3 } + + sipL3UnrecognizedIndividualDAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + + + +Brown & Tesink [Page 11] + +RFC 1694 SMDS Interface Objects August 1994 + + + remote system with invalid or unknown individual + destination addresses (Destination Address + Screening violations are not included). See SMDS + Subscription MIB module." + ::= { sipL3Entry 4 } + + sipL3UnrecognizedGAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + remote system with invalid or unknown group + addresses. (Destination Address Screening + violations are not included). See SMDS + Subscription MIB module." + ::= { sipL3Entry 5 } + + sipL3SentIndividualDAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifOutUcastPkts defined in [9] must be used instead. + DESCRIPTION + "The number of individually addressed SIP Level 3 + PDUs that have been sent by this system across the + SNI." + ::= { sipL3Entry 6 } + + sipL3SentGAs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifOutMulticastPkts defined in [9] must be used instead. + DESCRIPTION + "The number of group addressed SIP L3PDUs that + have been sent by this system across the SNI." + ::= { sipL3Entry 7 } + + -- The total number of SIP L3PDU errors can be calculated as + -- (Syntactic errors + Semantic Service errors ) + -- Syntactic errors include: + -- sipL3Errors + -- Latest occurrences of syntactic error types are logged in + -- sipL3PDUErrorTable. + -- Semantic Service errors include: + + + +Brown & Tesink [Page 12] + +RFC 1694 SMDS Interface Objects August 1994 + + + -- sipL3UnrecognizedIndividualDAs + -- sipL3UnrecognizedGAs + -- sipL3InvalidSMDSAddressTypes + -- Note that public networks supporting SMDS may discard + -- SIP L3PDUs due to subscription violations. Related + -- managed objects are defined in Definitions of Managed + -- Objects for SMDS Subscription. + + sipL3Errors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifInErrors defined in [9] must be used instead. + DESCRIPTION + "The total number of SIP Level 3 PDUs received + from the remote system that were discovered to + have errors (including protocol processing and bit + errors but excluding addressing-related errors) + and were discarded. Includes both group addressed + L3PDUs and L3PDUs containing an individual + destination address." + ::= { sipL3Entry 8 } + + sipL3InvalidSMDSAddressTypes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS deprecated + -- Moved to ifTable + -- ifInUnknownProtos defined in [9] must be used instead. + DESCRIPTION + "The number of SIP Level 3 PDUs received from the + remote system that had the Source or Destination + Address_Type subfields, (the four most significant + bits of the 64 bit address field), not equal to + the value 1100 or 1110. Also, an error is + considered to have occurred if the Address_Type + field for a Source Address, the four most + significant bits of the 64 bits, is equal to 1110 + (a group address)." + ::= { sipL3Entry 9 } + + sipL3VersionSupport OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value which indicates the version(s) of SIP + + + +Brown & Tesink [Page 13] + +RFC 1694 SMDS Interface Objects August 1994 + + + that this interface supports. The value is a sum. + This sum initially takes the value zero. For each + version, V, that this interface supports, 2 raised + to (V - 1) is added to the sum. For example, a + port supporting versions 1 and 2 would have a + value of (2^(1-1)+2^(2-1))=3. The + sipL3VersionSupport is effectively a bit mask with + Version 1 equal to the least significant bit + (LSB)." + ::= { sipL3Entry 10 } + + + -- The SIP Level 2 Group + + sipL2Table OBJECT-TYPE + SYNTAX SEQUENCE OF SipL2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains SIP L2PDU parameters and + state variables, one entry per SIP L2 interface." + ::= { sip 2 } + + sipL2Entry OBJECT-TYPE + SYNTAX SipL2Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This list contains SIP L2 parameters and state + variables." + INDEX { sipL2Index } + ::= { sipL2Table 1 } + + SipL2Entry ::= SEQUENCE { + sipL2Index IfIndex, + sipL2ReceivedCounts Counter32, + sipL2SentCounts Counter32, + sipL2HcsOrCRCErrors Counter32, + sipL2PayloadLengthErrors Counter32, + sipL2SequenceNumberErrors Counter32, + sipL2MidCurrentlyActiveErrors Counter32, + sipL2BomOrSSMsMIDErrors Counter32, + sipL2EomsMIDErrors Counter32 + } + + sipL2Index OBJECT-TYPE + SYNTAX IfIndex + MAX-ACCESS read-only + + + +Brown & Tesink [Page 14] + +RFC 1694 SMDS Interface Objects August 1994 + + + STATUS current + DESCRIPTION + "The value of this object identifies the SIP + interface for which this entry contains management + information." + ::= { sipL2Entry 1 } + + sipL2ReceivedCounts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of SIP Level 2 PDUs received from the + remote system across the SNI. The total includes + only unerrored L2PDUs." + ::= { sipL2Entry 2 } + + sipL2SentCounts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of SIP Level 2 PDUs that have been + sent by this system across the SNI." + ::= { sipL2Entry 3 } + + -- The following error types are counted, and + -- preclude sipL2ReceivedCounts to be incremented: + -- sipL2HcsOrCRCErrors + -- sipL2PayloadLengthErrors + -- sipL2SequenceNumberErrors + -- sipL2BomOrSSMsMIDErrors + -- sipL2EomsMIDErrors + -- The receipt of SIP Level 2 PDUs which are BOMs and + -- for with a MID that is already active will cause + -- sipL2MidCurrentlyActiveErrors to increment. + -- Any already accumulated (correct) segmentation + -- units are discarded.The sipL2ReceivedCounts + -- is incremented by 1. Thus, + -- sipL2ReceivedCounts defines the number of + -- correct SIP Level 2 PDUs delivered to the reassembly + -- process. + + sipL2HcsOrCRCErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Brown & Tesink [Page 15] + +RFC 1694 SMDS Interface Objects August 1994 + + + "The number of received SIP Level 2 PDUs that were + discovered to have either a Header Check Sequence + error or a Payload CRC violation." + ::= { sipL2Entry 4 } + + sipL2PayloadLengthErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of received SIP Level 2 PDUs that had + Payload Length errors that fall in the following + specifications: + - SSM L2_PDU payload length field value less + - than 28 octets or greater than 44 octets, + + - BOM or COM L2_PDU payload length field not + - equal to 44 octets, + - EOM L2_PDU payload length field value less + - than 4 octets or greater than 44 octets." + ::= { sipL2Entry 5 } + + sipL2SequenceNumberErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of received SIP Level 2 PDUs that had + a sequence number within the L2PDU not equal to + the expected sequence number of the SMDS SS + receive process." + ::= { sipL2Entry 6 } + + sipL2MidCurrentlyActiveErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of received SIP Level 2 PDUs that are + BOMs for which an active receive process is + already started." + ::= { sipL2Entry 7 } + + sipL2BomOrSSMsMIDErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Brown & Tesink [Page 16] + +RFC 1694 SMDS Interface Objects August 1994 + + + "The number of received SIP Level 2 PDUs that are + SSMs with a MID not equal to zero or are BOMs with + MIDs equal to zero." + ::= { sipL2Entry 8 } + + sipL2EomsMIDErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of received SIP Level 2 PDUs that are + EOMs for which there is no active receive process + for the MID (i.e., the receipt of an EOM which + does not correspond to a BOM) OR the EOM has a MID + equal to zero." + ::= { sipL2Entry 9 } + + + -- The SIP PLCP Group + + sipPLCP OBJECT IDENTIFIER ::= { sip 3 } + + + -- The DS1 PLCP Group + + sipDS1PLCPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipDS1PLCPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains SIP DS1 PLCP parameters and + state variables, one entry per SIP port." + ::= { sipPLCP 1 } + + sipDS1PLCPEntry OBJECT-TYPE + SYNTAX SipDS1PLCPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This list contains SIP DS1 PLCP parameters and + state variables." + INDEX { sipDS1PLCPIndex } + ::= { sipDS1PLCPTable 1 } + + SipDS1PLCPEntry ::= SEQUENCE { + sipDS1PLCPIndex IfIndex, + sipDS1PLCPSEFSs Counter32, + sipDS1PLCPAlarmState INTEGER, + + + +Brown & Tesink [Page 17] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipDS1PLCPUASs Counter32 + } + + sipDS1PLCPIndex OBJECT-TYPE + SYNTAX IfIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object identifies the + interface for which this entry contains management + information. " + ::= { sipDS1PLCPEntry 1 } + + sipDS1PLCPSEFSs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A DS1 Severely Errored Framing Second (SEFS) is a + count of one-second intervals containing one or + more SEF events. A Severely Errored Framing (SEF) + event is declared when an error in the A1 octet + and an error in the A2 octet of a framing octet + pair (i.e., errors in both framing octets), or two + consecutive invalid and/or nonsequential Path + Overhead Identifier octets are detected." + ::= { sipDS1PLCPEntry 2 } + + sipDS1PLCPAlarmState OBJECT-TYPE + SYNTAX INTEGER { + noAlarm (1), + receivedFarEndAlarm (2), + incomingLOF (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates if there is an alarm + present for the DS1 PLCP. The value + receivedFarEndAlarm means that the DS1 PLCP has + received an incoming Yellow Signal, the value + incomingLOF means that the DS1 PLCP has declared a + loss of frame (LOF) failure condition, and the + value noAlarm means that there are no alarms + present. See TR-TSV-000773 for a description of + alarm states." + ::= { sipDS1PLCPEntry 3 } + + + + +Brown & Tesink [Page 18] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipDS1PLCPUASs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, as defined by TR-TSV-000773, + encountered by the PLCP." + ::= { sipDS1PLCPEntry 4 } + + + -- The DS3 PLCP Group + + sipDS3PLCPTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipDS3PLCPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains SIP DS3 PLCP parameters and + state variables, one entry per SIP port." + ::= { sipPLCP 2 } + + sipDS3PLCPEntry OBJECT-TYPE + SYNTAX SipDS3PLCPEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This list contains SIP DS3 PLCP parameters and + state variables." + INDEX { sipDS3PLCPIndex } + ::= { sipDS3PLCPTable 1 } + + SipDS3PLCPEntry ::= SEQUENCE { + sipDS3PLCPIndex IfIndex, + sipDS3PLCPSEFSs Counter32, + sipDS3PLCPAlarmState INTEGER, + sipDS3PLCPUASs Counter32 + } + + sipDS3PLCPIndex OBJECT-TYPE + SYNTAX IfIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object identifies the + interface for which this entry contains management + information. " + ::= { sipDS3PLCPEntry 1 } + + + +Brown & Tesink [Page 19] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipDS3PLCPSEFSs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A DS3 Severely Errored Framing Second (SEFS) is a + count of one-second intervals containing one or + more SEF events. A Severely Errored Framing (SEF) + event is declared when an error in the A1 octet + and an error in the A2 octet of a framing octet + pair (i.e., errors in both framing octets), or two + consecutive invalid and/or nonsequential Path + Overhead Identifier octets are detected." + ::= { sipDS3PLCPEntry 2 } + + sipDS3PLCPAlarmState OBJECT-TYPE + SYNTAX INTEGER { + noAlarm (1), + receivedFarEndAlarm (2), + incomingLOF (3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This variable indicates if there is an alarm + present for the DS3 PLCP. The value + receivedFarEndAlarm means that the DS3 PLCP has + received an incoming Yellow Signal, the value + incomingLOF means that the DS3 PLCP has declared a + loss of frame (LOF) failure condition, and the + value noAlarm means that there are no alarms + present. See TR-TSV-000773 for a description of + alarm states." + ::= { sipDS3PLCPEntry 3 } + + sipDS3PLCPUASs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The counter associated with the number of + Unavailable Seconds, as defined by TR-TSV-000773, + encountered by the PLCP." + ::= { sipDS3PLCPEntry 4 } + + + -- The SMDS Applications group + -- Applications that have been identified for this group are: + + + +Brown & Tesink [Page 20] + +RFC 1694 SMDS Interface Objects August 1994 + + + -- * IP-over-SMDS (details are specified in RFC 1209) + + smdsApplications OBJECT IDENTIFIER ::= { sip 4 } + + ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 } + + -- Although the objects in this group are read-only, at the + -- agent's discretion they may be made read-write so that the + -- management station, when appropriately authorized, may + -- change the addressing information related to the + -- configuration of a logical IP subnetwork implemented on + -- top of SMDS. + + -- This table is necessary to support RFC1209 (IP-over-SMDS) + -- and gives information on the Group Addresses and ARP + -- Addresses used in the Logical IP subnetwork. + -- One SMDS address may be associated with multiple IP + -- addresses. One SNI may be associated with multiple LISs. + + ipOverSMDSTable OBJECT-TYPE + SYNTAX SEQUENCE OF IpOverSMDSEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The table of addressing information relevant to + this entity's IP addresses." + ::= { ipOverSMDS 1 } + + ipOverSMDSEntry OBJECT-TYPE + SYNTAX IpOverSMDSEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The addressing information for one of this + entity's IP addresses." + INDEX { ipOverSMDSIndex, ipOverSMDSAddress } + ::= { ipOverSMDSTable 1 } + + IpOverSMDSEntry ::= + SEQUENCE { + ipOverSMDSIndex IfIndex, + ipOverSMDSAddress IpAddress, + ipOverSMDSHA SMDSAddress, + ipOverSMDSLISGA SMDSAddress, + ipOverSMDSARPReq SMDSAddress + } + + ipOverSMDSIndex OBJECT-TYPE + + + +Brown & Tesink [Page 21] + +RFC 1694 SMDS Interface Objects August 1994 + + + SYNTAX IfIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object identifies the + interface for which this entry contains management + information. " + ::= { ipOverSMDSEntry 1 } + + ipOverSMDSAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP address to which this entry's addressing + information pertains." + ::= { ipOverSMDSEntry 2 } + + ipOverSMDSHA OBJECT-TYPE + SYNTAX SMDSAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SMDS Individual address of the IP station." + ::= { ipOverSMDSEntry 3 } + + ipOverSMDSLISGA OBJECT-TYPE + SYNTAX SMDSAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SMDS Group Address that has been configured + to identify the SMDS Subscriber-Network Interfaces + (SNIs) of all members of the Logical IP Subnetwork + (LIS) connected to the network supporting SMDS." + ::= { ipOverSMDSEntry 4 } + + ipOverSMDSARPReq OBJECT-TYPE + SYNTAX SMDSAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The SMDS address (individual or group) to which + ARP Requests are to be sent." + ::= { ipOverSMDSEntry 5 } + + + -- The SMDS Carrier Selection group + + + +Brown & Tesink [Page 22] + +RFC 1694 SMDS Interface Objects August 1994 + + + -- This group is used as a place holder + -- for carrier selection objects. + + smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 } + + + -- The SIP Error Log + + sipErrorLog OBJECT IDENTIFIER ::= { sip 6 } + + sipL3PDUErrorTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipL3PDUErrorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains the latest occurrence of + the following syntactical SIP L3PDU errors: + + - Destination Address Field Format Error, + + The following pertains to the 60 least significant + bits of the 64 bit address field. The 60 bits + contained in the address subfield can be used to + represent addresses up to 15 decimal digits. Each + decimal digit shall be encoded into four bits + using Binary Coded Decimal (BCD), with the most + significant digit occurring left-most. If not all + 15 digits are required, then the remainder of this + field shall be padded on the right with bits set + to one. An error is considered to have occurred: + a). if the first four bits of the address + subfield are not BCD, OR b). if the first four + bits of the address subfield are populated with + the country code value 0001, AND the 40 bits which + follow are not Binary Coded Decimal (BCD) encoded + values of the 10 digit addresses, OR the remaining + 16 least significant bits are not populated with + 1's, OR c). if the address subfield is not + correct according to another numbering plan which + is dependent upon the carrier assigning the + numbers and offering SMDS. + + - Source Address Field Format Error, + + The description of this parameter is the same as + the description of the Destination Address Field + Format Error. + + + + +Brown & Tesink [Page 23] + +RFC 1694 SMDS Interface Objects August 1994 + + + - Invalid BAsize Field Value, + + An error is considered to have occurred when the + BAsize field of an SIP L3PDU contains a value less + that 32, greater than 9220 octets without the + CRC32 field present, greater than 9224 octets with + the CRC32 field present, or not equal to a + multiple of 4 octets, + + - Invalid Header Extension Length Field Value, + + An error is considered to have occurred when the + Header Extension Length field value is not equal + 3. + + - Invalid Header Extension - Element Length, + + An error is considered to have occurred when the + Header Extension - Element Length is greater than + 12. + + - Invalid Header Extension - Version Element + Position, Length, or Value, + + An error is considered to have occurred when a + Version element with Length=3, Type=0, and Value=1 + does not appear first within the Header Extension, + or an element Type=0 appears somewhere other than + within the first three octets in the Header + Extension. + + - Invalid Header Extension - Carrier Selection + Element Position, Length, Value or Format, + + An error is considered to have occurred when a + Carrier Selection element does not appear second + within the Header Extension, if the Element Type + does not equal 1, the Element Length does not + equal 4, 6, or 8, the Element Value field is not + four BCD encoded decimal digits used in specifying + the Carrier Identification Code (CIC), or the + identified CIC code is invalid. + + - Header Extension PAD Error + + An error is considered to have occurred when the + Header Extension PAD is 9 octets in length, or if + the Header Extension PAD is greater than zero + + + +Brown & Tesink [Page 24] + +RFC 1694 SMDS Interface Objects August 1994 + + + octets in length and the Header Extension PAD does + not follow all Header Extension elements or does + not begin with at least one octet of all zeros. + + - BEtag Mismatch Error, + + An error is considered to have occurred when the + Beginning-End Tags in the SIP L3PDU header and + trailer are not equal. + + - BAsize Field not equal to Length Field Error, + + An error is considered to have occurred when the + value of the BAsize Field does not equal the value + of the Length Field. + + - Incorrect Length Error, and + + An error is considered to have occurred when the + the Length field value is not equal to the portion + of the SIP L3PDU which extends from the + Destination Address field up to and including the + CRC32 field (if present) or up to and including + the PAD field (if the CRC32 field is not present). + As an optional check, an error is considered to + have occurred when the length of a partially + received SIP L3PDU exceeds the BAsize value. + + - MRI Timeout Error. + + An error is considered to have occurred when the + elapsed time between receipt of BOM and + corresponding EOM exceeds the value of the MRI + (Message Receive Interval) for a particular + transport signal format. + + An entry is indexed by interface number and error + type, and contains Source Address, Destination + Address and a timestamp. All these errors are + counted in the sipL3Errors counter. When + sipL3PDUErrorTimeStamp is equal to zero, the + SipL3PDUErrorEntry does not contain any valid + information." + ::= { sipErrorLog 1 } + + sipL3PDUErrorEntry OBJECT-TYPE + SYNTAX SipL3PDUErrorEntry + MAX-ACCESS not-accessible + + + +Brown & Tesink [Page 25] + +RFC 1694 SMDS Interface Objects August 1994 + + + STATUS current + DESCRIPTION + "An entry in the service disagreement table." + INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType } + ::= { sipL3PDUErrorTable 1 } + + SipL3PDUErrorEntry ::= SEQUENCE { + sipL3PDUErrorIndex IfIndex, + sipL3PDUErrorType INTEGER, + sipL3PDUErrorSA SMDSAddress, + sipL3PDUErrorDA SMDSAddress, + sipL3PDUErrorTimeStamp TimeStamp + } + + sipL3PDUErrorIndex OBJECT-TYPE + SYNTAX IfIndex + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object identifies the + interface for which this entry contains management + information." + ::= { sipL3PDUErrorEntry 1 } + + sipL3PDUErrorType OBJECT-TYPE + SYNTAX INTEGER { + erroredDAFieldFormat (1), + erroredSAFieldFormat (2), + invalidBAsizeFieldValue (3), + invalidHdrExtLength (4), + invalidHdrExtElementLength (5), + invalidHdrExtVersionElementPositionLenthOrValue (6), + invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7), + hePADError (8), + beTagMismatch (9), + baSizeFieldNotEqualToLengthField (10), + incorrectLength (11), + mriTimeout (12) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of error." + ::= { sipL3PDUErrorEntry 2 } + + sipL3PDUErrorSA OBJECT-TYPE + SYNTAX SMDSAddress + MAX-ACCESS read-only + + + +Brown & Tesink [Page 26] + +RFC 1694 SMDS Interface Objects August 1994 + + + STATUS current + DESCRIPTION + "A rejected SMDS source address." + ::= { sipL3PDUErrorEntry 3 } + + sipL3PDUErrorDA OBJECT-TYPE + SYNTAX SMDSAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A rejected SMDS destination address." + ::= { sipL3PDUErrorEntry 4 } + + sipL3PDUErrorTimeStamp OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp for the service disagreement. The + timestamp contains the value of sysUpTime at the + latest occurrence of this type of service + disagreement. See textual description under + sipL3PDUErrorTable for boundary conditions." + ::= { sipL3PDUErrorEntry 5 } + + + -- The DXI Group + + sipDxiTable OBJECT-TYPE + SYNTAX SEQUENCE OF SipDxiEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The DXI table." + ::= { sipMIBObjects 1 } + + sipDxiEntry OBJECT-TYPE + SYNTAX SipDxiEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry in the DXI table." + INDEX { ifIndex } + ::= { sipDxiTable 1 } + + SipDxiEntry ::= + SEQUENCE { + sipDxiCrc + + + +Brown & Tesink [Page 27] + +RFC 1694 SMDS Interface Objects August 1994 + + + INTEGER, + sipDxiOutDiscards + Counter32, + sipDxiInErrors + Counter32, + sipDxiInAborts + Counter32, + sipDxiInTestFrames + Counter32, + sipDxiOutTestFrames + Counter32, + sipDxiHbpNoAcks + Counter32 + } + + sipDxiCrc OBJECT-TYPE + SYNTAX INTEGER { + crc16(1), + crc32(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of this object indicates the type + of Frame Checksum used by DXI. Current + choices include CCITT CRC16 or CRC32." + ::= { sipDxiEntry 1 } + + sipDxiOutDiscards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of outbound frames discarded + because of congestion." + ::= { sipDxiEntry 2 } + + sipDxiInErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of inbound frames discarded + because of errors such as frame checksum + (CRC) violations, + non-integral number of octets, address + and control field violations, and frame + size errors." + + + +Brown & Tesink [Page 28] + +RFC 1694 SMDS Interface Objects August 1994 + + + ::= { sipDxiEntry 3 } + + sipDxiInAborts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of inbound frames discarded + because of an abort bit sequence (1111111) + received before closing flag." + ::= { sipDxiEntry 4 } + + sipDxiInTestFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of unerrored, + inbound Test frames received + (generally as part of Heart + Beat Poll procedure)." + ::= { sipDxiEntry 5 } + + sipDxiOutTestFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of unerrored, + outbound Test frames sent + (generally as part of Heart + Beat Poll procedure)." + ::= { sipDxiEntry 6 } + + sipDxiHbpNoAcks OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Heart Beat + Poll (HBP) No Ack timeouts." + ::= { sipDxiEntry 7 } + + + -- conformance information + + smdsConformance OBJECT IDENTIFIER ::= { sipMIB 2 } + + + + +Brown & Tesink [Page 29] + +RFC 1694 SMDS Interface Objects August 1994 + + + smdsGroups OBJECT IDENTIFIER ::= { smdsConformance 1 } + smdsCompliances OBJECT IDENTIFIER ::= { smdsConformance 2 } + + + -- compliance statements + + smdsCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for SMDS interfaces." + + MODULE -- this module + MANDATORY-GROUPS { sipLevel3Stuff } + + GROUP sipLevel2Stuff + DESCRIPTION + "This group is mandatory only for those + interfaces (SNIs) which run SIP Level 2." + + GROUP sipDS1PLCPStuff + DESCRIPTION + "This group is mandatory only for those + interfaces (SNIs) which run the DS1 PLCP." + + GROUP sipDS3PLCPStuff + DESCRIPTION + "This group is mandatory only for those + interfaces (SNIs) which run the DS3 PLCP." + + GROUP sipIPApplicationsStuff + DESCRIPTION + "This group is mandatory only for interfaces + operating IP over SMDS in accordance with + RFC1209." + + GROUP sipDxiStuff + DESCRIPTION + "This group is mandatory only for those interfaces + (DXI-SNI) + which run the DXI protocol." + ::= { smdsCompliances 1 } + + -- units of conformance + + sipLevel3Stuff OBJECT-GROUP + OBJECTS { sipL3Index, + sipL3VersionSupport, sipL3PDUErrorIndex, + sipL3PDUErrorType, + + + +Brown & Tesink [Page 30] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipL3PDUErrorSA, sipL3PDUErrorDA, + sipL3PDUErrorTimeStamp } + STATUS current + DESCRIPTION + "A collection of objects providing information + applicable to all SMDS interfaces." + ::= { smdsGroups 1 } + + sipLevel2Stuff OBJECT-GROUP + OBJECTS { sipL2Index, sipL2HcsOrCRCErrors, + sipL2PayloadLengthErrors, + sipL2SequenceNumberErrors, + sipL2MidCurrentlyActiveErrors, + sipL2BomOrSSMsMIDErrors, + sipL2EomsMIDErrors } + STATUS current + DESCRIPTION + "A collection of objects providing information + specific to interfaces using the SIP Level 2." + ::= { smdsGroups 2 } + + sipDS1PLCPStuff OBJECT-GROUP + OBJECTS { sipDS1PLCPIndex, sipDS1PLCPSEFSs, + sipDS1PLCPAlarmState, sipDS1PLCPUASs } + STATUS current + DESCRIPTION + "A collection of objects providing information + specific to interfaces using the DS1 PLCP." + ::= { smdsGroups 3 } + + sipDS3PLCPStuff OBJECT-GROUP + OBJECTS { sipDS3PLCPIndex, sipDS3PLCPSEFSs, + sipDS3PLCPAlarmState, sipDS3PLCPUASs } + STATUS current + DESCRIPTION + "A collection of objects providing information + specific to interfaces using the DS3 PLCP." + ::= { smdsGroups 4 } + + + sipIPApplicationsStuff OBJECT-GROUP + OBJECTS { ipOverSMDSIndex, ipOverSMDSAddress, + ipOverSMDSHA, ipOverSMDSLISGA, ipOverSMDSARPReq } + STATUS current + DESCRIPTION + "A collection of objects providing information + for running IP over SMDS." + ::= { smdsGroups 5 } + + + +Brown & Tesink [Page 31] + +RFC 1694 SMDS Interface Objects August 1994 + + + sipDxiStuff OBJECT-GROUP + OBJECTS { sipDxiCrc, sipDxiOutDiscards, + sipDxiInErrors, sipDxiInAborts, + sipDxiInTestFrames, sipDxiOutTestFrames, + sipDxiHbpNoAcks } + STATUS current + DESCRIPTION + "A collection of objects providing information + specific to interfaces using the DXI protocol." + ::= { smdsGroups 6 } + + END + +5. Acknowledgments + + This specification is a product of the ifMIB Working Group. + +6. References + + [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure + of Management Information for version 2 of the Simple Network + Management Protocol (SNMPv2)", RFC 1442, SNMP Research, Inc., + Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon + University, April 1993. + + [2] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Textual + Conventions for version 2 of the the Simple Network Management + Protocol (SNMPv2)", RFC 1443, SNMP Research, Inc., Hughes LAN + Systems, Dover Beach Consulting, Inc., Carnegie Mellon + University, April 1993. + + [3] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, + "Conformance Statements for version 2 of the the Simple Network + Management Protocol (SNMPv2)", RFC 1444, SNMP Research, Inc., + Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon + University, April 1993. + + [4] Galvin, J., and K. McCloghrie, "Administrative Model for version + 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445, + Trusted Information Systems, Hughes LAN Systems, April 1993. + + [5] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol + Operations for version 2 of the Simple Network Management + Protocol (SNMPv2)", RFC 1448, SNMP Research, Inc., Hughes LAN + Systems, Dover Beach Consulting, Inc., Carnegie Mellon + University, April 1993. + + + + + +Brown & Tesink [Page 32] + +RFC 1694 SMDS Interface Objects August 1994 + + + [6] McCloghrie, K., and M. Rose, Editors, "Management Information + Base for Network Management of TCP/IP-based internets: MIB-II", + STD 17, RFC 1213, Hughes LAN Systems, Inc., Performance Systems + International, March 1991. + + [7] Information processing systems - Open Systems Interconnection - + Specification of Abstract Syntax Notation One (ASN.1), + International Organization for Standardization. International + Standard 8824, December 1987. + + [8] Information processing systems - Open Systems Interconnection - + Specification of Basic Encoding Rules for Abstract Notation One + (ASN.1), International Organization for Standardization. + International Standard 8825, December 1987. + + [9] McCloghrie, K., and F. Kastenholz, "Evolution of Interfaces Group + of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software, January + 1994. + + [10] Cox, T., and K. Tesink, Editors, "Definitions of Managed Objects + for the DS3/E3 Interface Type", RFC 1407, Bellcore, January 1993. + + [11] Baker, F., and J. Watt, Editors, "Definitions of Managed Objects + for the DS1/E1 Interface Type", RFC 1406, Advanced Computer + Communications, Newbridge Networks Corporation, January 1993. + + [12] Cox, T., and K. Tesink, Editors, "Definition of Managed Objects + for the SMDS Interface Type", RFC 1304, Bellcore, February 1992. + + [13] "Generic System Requirements in Support of Switched Multi-megabit + Data Service", Bellcore Technical Reference, TR-TSV-000772, Issue + 1, May 1991. + + [14] "Local Access System Generic Requirements, Objectives, and + Interfaces in Support of Switched Multi-megabit Data Service", + Bellcore Technical Reference, TR-TSV-000773, Issue 1, June 1990. + + [15] Piscitello, D., and J. Lawrence, Editors, The Transmission of IP + Datagrams over the SMDS Service", RFC 1209, Bell Communications + Research, March 1991. + + [16] "Generic Requirements For SMDS Customer Network Management + Service", Bellcore TR-TSV-001062, Issue 1, March 1993, and + Supplement 1, December 1993. + + [17] Cox, R., and K. Tesink, "Definitions of Managed Objects for SMDS + Subscription", Version 2.1, Bellcore, August 1992. + + + + +Brown & Tesink [Page 33] + +RFC 1694 SMDS Interface Objects August 1994 + + + [18] Frame Based Interface Protocol for SMDS Networks - Data Exchange + Interface / Subscriber Network Interface Revision 1.0 - SMDS + Interest Group SIG-TS-005/1993, February 2, 1993. + + [19] Frame Based Interface Protocol for SMDS Networks - SIP Relay + Interface Revision 1.0 - SMDS Interest Group SIG-TS-006/1993, + February 2, 1993. + + [20] "Generic Requirements For Low Speed SMDS Access", Bellcore TR- + TSV-001239, Issue 1, December 1993. + + [21] ATM Forum, "ATM User Network Interface Specification", Version + 3.0, September 1993. + + [22] Ahmed, M., and K. Tesink, Editors, "Definitions of Managed + Objects for ATM Management", RFC 1695, Bellcore, August 1994. + + [23] Brown, R., Editor, "Definitions of Managed Objects for Frame + Relay Service", RFC 1604, Bellcore, March 1994. + + [24] Specification for Implementation of SMDS over an ATM-based Public + UNI - Cedric Druce, Max Figueroa, Bellcore - SIG TWG-1993/043, + SMDS Interest Group Technical Working Group, Work in Progress, + August 24, 1993. + + [25] Brown, T. and K. Tesink, Editors), "Definitions of Managed + Objects for the SONET Interface Type, RFC 1595, Bellcore, March + 1994. + +7. Security Considerations + + Security issues are not discussed in this memo. + + + + + + + + + + + + + + + + + + + +Brown & Tesink [Page 34] + +RFC 1694 SMDS Interface Objects August 1994 + + +8. Authors' Addresses + + Tracy A. Brown + Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + + Phone: (908) 758-2107 + EMail: tacox@mail.bellcore.com + + + Kaj Tesink + Bell Communications Research + 331 Newman Springs Road + P.O. Box 7020 + Red Bank, NJ 07701-7020 + + Phone: (908) 758-5254 + EMail: kaj@cc.bellcore.com + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +Brown & Tesink [Page 35] + |