+Network Working Group T. Brown
+Request for Comments: 1694 K. Tesink
+Obsoletes: 1304 Editors
+Category: Standards Track Bell Communications Research
+ August 1994
+
+
+ Definitions of Managed Objects
+ for SMDS Interfaces using SMIv2
+
+Status of this Memo
+
+ This document specifies an Internet standards track protocol for the
+ Internet community, and requests discussion and suggestions for
+ improvements. Please refer to the current edition of the "Internet
+ Official Protocol Standards" (STD 1) for the standardization state
+ and status of this protocol. Distribution of this memo is unlimited.
+
+Abstract
+
+ This memo defines a portion of the Management Information Base (MIB)
+ for use with network management protocols in TCP/IP-based internets.
+ In particular, it defines objects for managing objects for SMDS
+ access interfaces. This includes the following access protocols:
+
+ SIP [13]
+ SIP/DXI [18] and [20]
+ SIP/FR [19]
+ SIP/ATM [24]
+
+ This memo replaces RFC 1304 [12], and defines a MIB module which is
+ both compliant to the SNMPv2 SMI and semantically-identical to the
+ existing RFC 1304-based definitions.
+
+ This memo also assumes application of the MIB II Interfaces group as
+ defined in [9].
+
+Table of Contents
+
+ 1. The SNMPv2 Network Management Framework ............... 2
+ 2. Objects ............................................... 3
+ 2.1 Format of Definitions ................................ 3
+ 3. Overview .............................................. 4
+ 3.1 SIP Level 3 .......................................... 5
+ 4. Object Definitions .................................... 9
+ 4.1 The SIP Level 3 Group ................................ 10
+ 4.2 The SIP Level 2 Group ................................ 14
+ 4.3 The SIP PLCP Group ................................... 17
+
+
+
+Brown & Tesink [Page 1]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ 4.3.1 The DS1 PLCP Group ................................. 17
+ 4.3.2 The DS3 PLCP Group ................................. 19
+ 4.4 The SMDS Applications Group .......................... 20
+ 4.4.1 The IP over SMDS Group ............................. 21
+ 4.5 The SMDS Carrier Selection Group ..................... 22
+ 4.6 The SIP Error Log Group .............................. 23
+ 4.7 The Data eXchange Interface Group .................... 27
+ 4.8 Conformance Information .............................. 29
+ 5. Acknowledgments ....................................... 32
+ 6. References ............................................ 32
+ 7. Security Considerations ............................... 34
+ 8. Authors' Addresses .................................... 35
+
+1. The SNMPv2 Network Management Framework
+
+ The SNMPv2 Network Management Framework consists of four major
+ components. They are:
+
+ o RFC 1442 [1] which defines the SMI, the mechanisms used for
+ describing and naming objects for the purpose of
+ management.
+
+ o STD 17, RFC 1213 [6] defines MIB-II, the core set of managed
+ objects for the Internet suite of protocols. Reference [12]
+ defines the evolution of the Interfaces Group of MIB II in
+ terms of extensions and precise applications of the objects.
+
+ o RFC 1445 [4] which defines the administrative and other
+ architectural aspects of the framework.
+
+ o RFC 1448 [5] which defines the protocol used for network
+ access to managed objects.
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+ This specification makes also use of:
+
+ o RFC 1443 [2] which defines textual conventions for the
+ specification of managed objects.
+
+ o RFC 1444 [3] which defines conformance statements for the
+ specification of managed objects.
+
+
+
+
+
+
+
+
+Brown & Tesink [Page 2]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+2. Objects
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation One (ASN.1) [7]
+ defined in the SMI. In particular, each object has a name, a syntax,
+ and an encoding. The name is an object identifier, an
+ administratively assigned name, which specifies an object type. The
+ object type together with an object instance serves to uniquely
+ identify a specific instantiation of the object. For human
+ convenience, we often use a textual string, termed the OBJECT
+ DESCRIPTOR, to also refer to the object type.
+
+ The syntax of an object type defines the abstract data structure
+ corresponding to that object type. The ASN.1 language is used for
+ this purpose. However, the SMI RFC 1442 purposely restricts the
+ ASN.1 constructs which may be used. These restrictions are
+ explicitly made for simplicity.
+
+ The encoding of an object type is simply how that object type is
+ represented using the object type's syntax. Implicitly tied to the
+ notion of an object type's syntax and encoding is how the object type
+ is represented when being transmitted on the network. The SMI
+ specifies the use of the basic encoding rules of ASN.1 [8], subject
+ to the additional requirements imposed by the SNMP.
+
+2.1. Format of Definitions
+
+ Section 4 contains contains the specification of all object types
+ contained in this MIB module. The object types are defined using the
+ conventions defined in the SMI, as amended by the extensions
+ specified in the SNMPv2 SMI.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brown & Tesink [Page 3]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+3. Overview
+
+ SMDS is a service that can be provided by numerous interface
+ protocols as shown in the following figure:
+
+ +-------------------+ +-------------------+
+ | SIP Level 3* [13] | | SIP Level 3* [13] |
+ +-------------------+ +-------------------+
+ | SIP Level 2* [13] | | DXI Level 2* [20] |
+ +-------------------+ +-------------------+
+ | SIP PLCP* [14] | | |
+ +-------------------+ | DXI Level 1 [20] |
+ | SIP Level 1 [14] | | |
+ +-------------------+ +-------------------+
+ SIP based access DXI based access
+
+ +-------------------+ +-------------------+
+ | SIP Level 3* [13] | | SIP Level 3* [13] |
+ +-------------------+ +-------------------+
+ | ATM [21] | | Frame Relay [19] |
+ +-------------------+ +-------------------+
+ | ATM PLCP [21] | | |
+ +-------------------+ | Frame Relay [19] |
+ | ATM Level 1 [21] | | Level 1 |
+ +-------------------+ +-------------------+
+ ATM based access FR based access
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brown & Tesink [Page 4]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ In the figure below, managed objects for the protocol levels marked
+ with a (*) are defined in this memo. Additional managed objects that
+ must be used to manage SMDS interfaces are defined in other MIB
+ modules as indicated in the figure.
+
+ +-------------------+ +-------------------+
+ | SIP Level 3* | | SIP Level 3* |
+ +-------------------+ +-------------------+
+ | SIP Level 2* | | DXI Level 2* |
+ +-------------------+ +-------------------+
+ | SIP PLCP* | | |
+ +-------------------+ | DXI Level 1 |
+ | SIP Level 1 | | |
+ | [10] or [11] | | [10] |
+ +-------------------+ +-------------------+
+ SIP based access DXI based access
+
+ +-------------------+ +-------------------+
+ | SIP Level 3* | | SIP Level 3* |
+ +-------------------+ +-------------------+
+ | ATM [22] | | Frame Relay [23] |
+ +-------------------+ +-------------------+
+ | ATM PLCP/TC [22] | | |
+ +-------------------+ | Frame Relay |
+ | ATM Level 1 [10] | | Level 1 |
+ | [11], or [25] | | [10] or [11] |
+ +-------------------+ +-------------------+
+ ATM based access FR based access
+
+ With the improved interpretation of the MIB II interfaces group [9],
+ some objects can be represented by ifTable. This means that these
+ objects have been deprecated from the MIB module defined in RFC 1304,
+ and ifTable is used instead. No semantical changes have been made to
+ these objects. Only the object identifiers and object descriptors
+ have been changed to the objects defined in ifTable.
+
+ Implementation experience has shown that the objects
+ sipL3UnrecognizedIndividualDAs and sipL3UnrecognizedGAs were not
+ supported.
+
+3.1. SIP Level 3
+
+ Objects for SIP Level 3 apply to all methods to access SMDS shown in
+ the figures above. With the improved interpretation of the MIB II
+ interfaces group, most objects can be represented by ifTable. The
+ appropriate mapping is defined below.
+
+
+
+
+
+Brown & Tesink [Page 5]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ This document does not specify objects for the management of
+ subscription or configuration of Subscriber-Network Interfaces
+ (SNIs). Those objects are defined in Definitions of Managed Objects
+ for SMDS Subscription [17]. Bellcore requirements on these objects
+ are specified in TR-TSV-001062 [16].
+
+ ifTable Object Use for
+ ======================================================
+ ifIndex Interface index.
+
+ ifDescr Interface description.
+ For example, SIP Level 3 sublayer
+ of a SNI.
+
+ ifType Set to 31.
+
+ ifMtu Set to 9232.
+
+ ifSpeed Peak bandwidth in bits per second available
+ for use as provided by the supporting Level
+ 2 protocol. For example, 1.17 Mbps when
+ using SIP based DS1 SNIs, and 1.536 Mbps
+ when using DXI-based DS1 DXI-SNI.
+
+ ifPhysAddress OCTET STRING of Size 8. Value is
+ a 16-digit Binary Coded Decimal
+ SMDS address that is
+ assigned to this interface.
+
+ ifAdminStatus The desired administrative status of the
+ SMDS interface.
+
+ ifOperStatus The current operational status of the
+ SMDS interface.
+
+ ifLastChange The elapsed time since the last
+ re-initialization of the interface.
+ The value of sysUpTime at the time the
+ interface entered its current
+ operational state. If the current
+ state was entered prior to the last
+ re-initialization of the local
+ network management subsystem, then
+ this object contains a zero value.
+
+ ifInOctets Number of received octets at SIP Level 3.
+ For SIP based SNIs, this is the number of
+ sipL2ReceivedCounts multiplied by 44.
+
+
+
+Brown & Tesink [Page 6]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ ifInUcastPkts The total number of individually addressed
+ SIP Level 3 PDUs received from the remote
+ system across the SNI. The total includes
+ only unerrored SIP Level 3 PDUs.
+ [identical to RFC1304:
+ sipL3ReceivedIndividualDAs]
+
+ ifInDiscards The number of received SIP Level 3 PDUs
+ discarded. For SMDS interfaces, this
+ counter will always be zero.
+
+ ifInErrors The total number of SIP Level 3 PDUs
+ received from the remote system that were
+ discovered to have errors (including
+ protocol processing and bit errors but
+ excluding addressing-related errors) and
+ were discarded. Includes both group
+ addressed SIP Level 3 PDUs and SIP Level
+ 3 PDUs containing an individual
+ destination address.
+ [identical to RFC1304: sipL3Errors]
+
+ ifInUnknownProtos The number of SIP Level 3 PDUs received
+ from the remote system with a Source or
+ Destination Address_Type subfields, (the
+ four most significant bits of the 64 bit
+ address field), not equal to the value
+ 1100 or 1110. Also, an error is
+ considered to have occurred if the
+ Address_Type field for a Source Address
+ is equal to 1110 (a group address).
+ [identical to RFC1304:
+ sipL3InvalidSMDSAddressTypes]
+
+ ifOutOctets Number of received octets for transmission
+ at SIP Level 3. For SIP based
+ SNIs, this is the number
+ of sipL2SentCounts multiplied by 44.
+
+ ifOutUcastPkts The number of individually addressed SIP
+ Level 3 PDUs that have been sent by this
+ system across the interface.
+ [identical to RFC1304:
+ sipL3SentIndividualDAs]
+
+ ifOutDiscards The number of SIP Level 3 PDUs discarded in
+ the egress direction. For SMDS interfaces,
+ this counter will always be zero.
+
+
+
+Brown & Tesink [Page 7]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ ifOutErrors The number of SIP Level 3 PDUs
+ discarded in the egress
+ direction, because of errors.
+ For SMDS interfaces, this counter will
+ always be zero.
+
+ ifName The textual name of the interface.
+ If not used, this variable contains
+ a zero-length string.
+
+ ifInMulticastPkts The total number of group addressed SIP
+ Level 3 PDUs received from the remote
+ system across the interface. The total
+ includes only unerrored SIP Level 3 PDUs.
+ [identical to RFC1304: sipL3ReceivedGAs]
+
+ ifInBroadcastPkts This variable is not applicable for SMDS
+ interfaces. Therefore, this counter is
+ always zero.
+
+ ifOutMulticastPkts The number of group addressed SIP Level 3
+ PDUs that have been sent by this system
+ across the interface.
+ [identical to RFC1304: sipL3SentGAs]
+
+ ifOutBroadcastPkts This variable is not applicable for SMDS
+ interfaces. Therefore, this counter is
+ always zero.
+
+ ifLinkUpDownTrapEnble The value of this object is
+ disabled(2) for SIP Level 3 interfaces.
+
+ ifHighSpeed Set to the user data rate of the
+ interface in millions of bits per second.
+ If the user data rate is less than 1 Mbps,
+ then this value is zero.
+
+ ifPromiscuousMode Set to false(2).
+
+ ifConnectorPresent Set to false(2).
+
+ Consult the Evolution of the Interfaces Group [9] for when to use the
+ HC (High Capacity) counters (e.g., ifHCInOctets is a 64-bit counter).
+
+
+
+
+
+
+
+
+Brown & Tesink [Page 8]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+4. Object Definitions
+
+ SIP-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, Counter32,
+ Integer32, IpAddress FROM SNMPv2-SMI
+ TimeStamp, TEXTUAL-CONVENTION FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
+ transmission, ifIndex, mib-2 FROM RFC1213-MIB;
+
+ -- This is the MIB module for the SMDS Interface objects.
+
+ sipMIB MODULE-IDENTITY
+ LAST-UPDATED "9403311818Z"
+ ORGANIZATION "IETF Interfaces Working Group"
+ CONTACT-INFO
+ " Tracy Brown
+ Postal: Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+ US
+
+ Tel: +1 908 758-2107
+ Fax: +1 908 758-4177
+ E-mail: tacox@mail.bellcore.com
+
+ Kaj Tesink
+ Postal: Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+ US
+
+ Tel: +1 908 758 5254
+ Fax: +1 908 758 4177
+ E-mail: kaj@cc.bellcore.com."
+ DESCRIPTION
+ "The MIB module to describe
+ SMDS interfaces objects."
+ ::= { mib-2 36 }
+
+ SMDSAddress ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "1h:"
+ STATUS current
+ DESCRIPTION
+ "The 60-bit SMDS address,
+
+
+
+Brown & Tesink [Page 9]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ preceded by 4 bits with the following values:
+ 1100 when representing an individual address
+ 1110 when representing a group address."
+ SYNTAX OCTET STRING (SIZE (8))
+
+ IfIndex ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the
+ interface for which this entry contains
+ management information. The value of this
+ object for a particular interface has the same
+ value as the ifIndex object, defined in RFC
+ 1213, for the same interface."
+ SYNTAX Integer32
+
+
+ sip OBJECT IDENTIFIER ::= { transmission 31 }
+ sipMIBObjects OBJECT IDENTIFIER ::= { sipMIB 1 }
+
+
+ -- The SIP Level 3 Group
+
+ sipL3Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL3Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains SIP L3 parameters and
+ state variables, one entry per SIPL3 interface."
+ ::= { sip 1 }
+
+ sipL3Entry OBJECT-TYPE
+ SYNTAX SipL3Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This list contains SIP L3 parameters and
+ state variables."
+ INDEX { sipL3Index }
+ ::= { sipL3Table 1 }
+
+ SipL3Entry ::= SEQUENCE {
+ sipL3Index IfIndex,
+ sipL3ReceivedIndividualDAs Counter32,
+ sipL3ReceivedGAs Counter32,
+ sipL3UnrecognizedIndividualDAs Counter32,
+ sipL3UnrecognizedGAs Counter32,
+
+
+
+Brown & Tesink [Page 10]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipL3SentIndividualDAs Counter32,
+ sipL3SentGAs Counter32,
+ sipL3Errors Counter32,
+ sipL3InvalidSMDSAddressTypes Counter32,
+ sipL3VersionSupport Integer32
+ }
+
+ sipL3Index OBJECT-TYPE
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the SIP
+ L3 interface for which this entry contains
+ management information. "
+ ::= { sipL3Entry 1 }
+
+ sipL3ReceivedIndividualDAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifInUcastPkts defined in [9] must be used instead.
+ DESCRIPTION
+ "The total number of individually addressed SIP
+ Level 3 PDUs received from the remote system
+ across the SNI. The total includes only
+ unerrored L3PDUs."
+ ::= { sipL3Entry 2 }
+
+ sipL3ReceivedGAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifInMulticastPkts defined in [9] must be used instead.
+ DESCRIPTION
+ "The total number of group addressed SIP Level 3
+ PDUs received from the remote system across the
+ SNI. The total includes only unerrored L3PDUs."
+ ::= { sipL3Entry 3 }
+
+ sipL3UnrecognizedIndividualDAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+
+
+
+Brown & Tesink [Page 11]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ remote system with invalid or unknown individual
+ destination addresses (Destination Address
+ Screening violations are not included). See SMDS
+ Subscription MIB module."
+ ::= { sipL3Entry 4 }
+
+ sipL3UnrecognizedGAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+ remote system with invalid or unknown group
+ addresses. (Destination Address Screening
+ violations are not included). See SMDS
+ Subscription MIB module."
+ ::= { sipL3Entry 5 }
+
+ sipL3SentIndividualDAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifOutUcastPkts defined in [9] must be used instead.
+ DESCRIPTION
+ "The number of individually addressed SIP Level 3
+ PDUs that have been sent by this system across the
+ SNI."
+ ::= { sipL3Entry 6 }
+
+ sipL3SentGAs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifOutMulticastPkts defined in [9] must be used instead.
+ DESCRIPTION
+ "The number of group addressed SIP L3PDUs that
+ have been sent by this system across the SNI."
+ ::= { sipL3Entry 7 }
+
+ -- The total number of SIP L3PDU errors can be calculated as
+ -- (Syntactic errors + Semantic Service errors )
+ -- Syntactic errors include:
+ -- sipL3Errors
+ -- Latest occurrences of syntactic error types are logged in
+ -- sipL3PDUErrorTable.
+ -- Semantic Service errors include:
+
+
+
+Brown & Tesink [Page 12]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ -- sipL3UnrecognizedIndividualDAs
+ -- sipL3UnrecognizedGAs
+ -- sipL3InvalidSMDSAddressTypes
+ -- Note that public networks supporting SMDS may discard
+ -- SIP L3PDUs due to subscription violations. Related
+ -- managed objects are defined in Definitions of Managed
+ -- Objects for SMDS Subscription.
+
+ sipL3Errors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifInErrors defined in [9] must be used instead.
+ DESCRIPTION
+ "The total number of SIP Level 3 PDUs received
+ from the remote system that were discovered to
+ have errors (including protocol processing and bit
+ errors but excluding addressing-related errors)
+ and were discarded. Includes both group addressed
+ L3PDUs and L3PDUs containing an individual
+ destination address."
+ ::= { sipL3Entry 8 }
+
+ sipL3InvalidSMDSAddressTypes OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ -- Moved to ifTable
+ -- ifInUnknownProtos defined in [9] must be used instead.
+ DESCRIPTION
+ "The number of SIP Level 3 PDUs received from the
+ remote system that had the Source or Destination
+ Address_Type subfields, (the four most significant
+ bits of the 64 bit address field), not equal to
+ the value 1100 or 1110. Also, an error is
+ considered to have occurred if the Address_Type
+ field for a Source Address, the four most
+ significant bits of the 64 bits, is equal to 1110
+ (a group address)."
+ ::= { sipL3Entry 9 }
+
+ sipL3VersionSupport OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A value which indicates the version(s) of SIP
+
+
+
+Brown & Tesink [Page 13]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ that this interface supports. The value is a sum.
+ This sum initially takes the value zero. For each
+ version, V, that this interface supports, 2 raised
+ to (V - 1) is added to the sum. For example, a
+ port supporting versions 1 and 2 would have a
+ value of (2^(1-1)+2^(2-1))=3. The
+ sipL3VersionSupport is effectively a bit mask with
+ Version 1 equal to the least significant bit
+ (LSB)."
+ ::= { sipL3Entry 10 }
+
+
+ -- The SIP Level 2 Group
+
+ sipL2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains SIP L2PDU parameters and
+ state variables, one entry per SIP L2 interface."
+ ::= { sip 2 }
+
+ sipL2Entry OBJECT-TYPE
+ SYNTAX SipL2Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This list contains SIP L2 parameters and state
+ variables."
+ INDEX { sipL2Index }
+ ::= { sipL2Table 1 }
+
+ SipL2Entry ::= SEQUENCE {
+ sipL2Index IfIndex,
+ sipL2ReceivedCounts Counter32,
+ sipL2SentCounts Counter32,
+ sipL2HcsOrCRCErrors Counter32,
+ sipL2PayloadLengthErrors Counter32,
+ sipL2SequenceNumberErrors Counter32,
+ sipL2MidCurrentlyActiveErrors Counter32,
+ sipL2BomOrSSMsMIDErrors Counter32,
+ sipL2EomsMIDErrors Counter32
+ }
+
+ sipL2Index OBJECT-TYPE
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+
+
+
+Brown & Tesink [Page 14]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the SIP
+ interface for which this entry contains management
+ information."
+ ::= { sipL2Entry 1 }
+
+ sipL2ReceivedCounts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of SIP Level 2 PDUs received from the
+ remote system across the SNI. The total includes
+ only unerrored L2PDUs."
+ ::= { sipL2Entry 2 }
+
+ sipL2SentCounts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of SIP Level 2 PDUs that have been
+ sent by this system across the SNI."
+ ::= { sipL2Entry 3 }
+
+ -- The following error types are counted, and
+ -- preclude sipL2ReceivedCounts to be incremented:
+ -- sipL2HcsOrCRCErrors
+ -- sipL2PayloadLengthErrors
+ -- sipL2SequenceNumberErrors
+ -- sipL2BomOrSSMsMIDErrors
+ -- sipL2EomsMIDErrors
+ -- The receipt of SIP Level 2 PDUs which are BOMs and
+ -- for with a MID that is already active will cause
+ -- sipL2MidCurrentlyActiveErrors to increment.
+ -- Any already accumulated (correct) segmentation
+ -- units are discarded.The sipL2ReceivedCounts
+ -- is incremented by 1. Thus,
+ -- sipL2ReceivedCounts defines the number of
+ -- correct SIP Level 2 PDUs delivered to the reassembly
+ -- process.
+
+ sipL2HcsOrCRCErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+
+
+
+Brown & Tesink [Page 15]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ "The number of received SIP Level 2 PDUs that were
+ discovered to have either a Header Check Sequence
+ error or a Payload CRC violation."
+ ::= { sipL2Entry 4 }
+
+ sipL2PayloadLengthErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that had
+ Payload Length errors that fall in the following
+ specifications:
+ - SSM L2_PDU payload length field value less
+ - than 28 octets or greater than 44 octets,
+
+ - BOM or COM L2_PDU payload length field not
+ - equal to 44 octets,
+ - EOM L2_PDU payload length field value less
+ - than 4 octets or greater than 44 octets."
+ ::= { sipL2Entry 5 }
+
+ sipL2SequenceNumberErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that had
+ a sequence number within the L2PDU not equal to
+ the expected sequence number of the SMDS SS
+ receive process."
+ ::= { sipL2Entry 6 }
+
+ sipL2MidCurrentlyActiveErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that are
+ BOMs for which an active receive process is
+ already started."
+ ::= { sipL2Entry 7 }
+
+ sipL2BomOrSSMsMIDErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+
+
+
+Brown & Tesink [Page 16]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ "The number of received SIP Level 2 PDUs that are
+ SSMs with a MID not equal to zero or are BOMs with
+ MIDs equal to zero."
+ ::= { sipL2Entry 8 }
+
+ sipL2EomsMIDErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of received SIP Level 2 PDUs that are
+ EOMs for which there is no active receive process
+ for the MID (i.e., the receipt of an EOM which
+ does not correspond to a BOM) OR the EOM has a MID
+ equal to zero."
+ ::= { sipL2Entry 9 }
+
+
+ -- The SIP PLCP Group
+
+ sipPLCP OBJECT IDENTIFIER ::= { sip 3 }
+
+
+ -- The DS1 PLCP Group
+
+ sipDS1PLCPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipDS1PLCPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains SIP DS1 PLCP parameters and
+ state variables, one entry per SIP port."
+ ::= { sipPLCP 1 }
+
+ sipDS1PLCPEntry OBJECT-TYPE
+ SYNTAX SipDS1PLCPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This list contains SIP DS1 PLCP parameters and
+ state variables."
+ INDEX { sipDS1PLCPIndex }
+ ::= { sipDS1PLCPTable 1 }
+
+ SipDS1PLCPEntry ::= SEQUENCE {
+ sipDS1PLCPIndex IfIndex,
+ sipDS1PLCPSEFSs Counter32,
+ sipDS1PLCPAlarmState INTEGER,
+
+
+
+Brown & Tesink [Page 17]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipDS1PLCPUASs Counter32
+ }
+
+ sipDS1PLCPIndex OBJECT-TYPE
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the
+ interface for which this entry contains management
+ information. "
+ ::= { sipDS1PLCPEntry 1 }
+
+ sipDS1PLCPSEFSs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A DS1 Severely Errored Framing Second (SEFS) is a
+ count of one-second intervals containing one or
+ more SEF events. A Severely Errored Framing (SEF)
+ event is declared when an error in the A1 octet
+ and an error in the A2 octet of a framing octet
+ pair (i.e., errors in both framing octets), or two
+ consecutive invalid and/or nonsequential Path
+ Overhead Identifier octets are detected."
+ ::= { sipDS1PLCPEntry 2 }
+
+ sipDS1PLCPAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm (1),
+ receivedFarEndAlarm (2),
+ incomingLOF (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates if there is an alarm
+ present for the DS1 PLCP. The value
+ receivedFarEndAlarm means that the DS1 PLCP has
+ received an incoming Yellow Signal, the value
+ incomingLOF means that the DS1 PLCP has declared a
+ loss of frame (LOF) failure condition, and the
+ value noAlarm means that there are no alarms
+ present. See TR-TSV-000773 for a description of
+ alarm states."
+ ::= { sipDS1PLCPEntry 3 }
+
+
+
+
+Brown & Tesink [Page 18]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipDS1PLCPUASs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, as defined by TR-TSV-000773,
+ encountered by the PLCP."
+ ::= { sipDS1PLCPEntry 4 }
+
+
+ -- The DS3 PLCP Group
+
+ sipDS3PLCPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipDS3PLCPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains SIP DS3 PLCP parameters and
+ state variables, one entry per SIP port."
+ ::= { sipPLCP 2 }
+
+ sipDS3PLCPEntry OBJECT-TYPE
+ SYNTAX SipDS3PLCPEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This list contains SIP DS3 PLCP parameters and
+ state variables."
+ INDEX { sipDS3PLCPIndex }
+ ::= { sipDS3PLCPTable 1 }
+
+ SipDS3PLCPEntry ::= SEQUENCE {
+ sipDS3PLCPIndex IfIndex,
+ sipDS3PLCPSEFSs Counter32,
+ sipDS3PLCPAlarmState INTEGER,
+ sipDS3PLCPUASs Counter32
+ }
+
+ sipDS3PLCPIndex OBJECT-TYPE
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the
+ interface for which this entry contains management
+ information. "
+ ::= { sipDS3PLCPEntry 1 }
+
+
+
+Brown & Tesink [Page 19]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipDS3PLCPSEFSs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A DS3 Severely Errored Framing Second (SEFS) is a
+ count of one-second intervals containing one or
+ more SEF events. A Severely Errored Framing (SEF)
+ event is declared when an error in the A1 octet
+ and an error in the A2 octet of a framing octet
+ pair (i.e., errors in both framing octets), or two
+ consecutive invalid and/or nonsequential Path
+ Overhead Identifier octets are detected."
+ ::= { sipDS3PLCPEntry 2 }
+
+ sipDS3PLCPAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ noAlarm (1),
+ receivedFarEndAlarm (2),
+ incomingLOF (3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This variable indicates if there is an alarm
+ present for the DS3 PLCP. The value
+ receivedFarEndAlarm means that the DS3 PLCP has
+ received an incoming Yellow Signal, the value
+ incomingLOF means that the DS3 PLCP has declared a
+ loss of frame (LOF) failure condition, and the
+ value noAlarm means that there are no alarms
+ present. See TR-TSV-000773 for a description of
+ alarm states."
+ ::= { sipDS3PLCPEntry 3 }
+
+ sipDS3PLCPUASs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The counter associated with the number of
+ Unavailable Seconds, as defined by TR-TSV-000773,
+ encountered by the PLCP."
+ ::= { sipDS3PLCPEntry 4 }
+
+
+ -- The SMDS Applications group
+ -- Applications that have been identified for this group are:
+
+
+
+Brown & Tesink [Page 20]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ -- * IP-over-SMDS (details are specified in RFC 1209)
+
+ smdsApplications OBJECT IDENTIFIER ::= { sip 4 }
+
+ ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }
+
+ -- Although the objects in this group are read-only, at the
+ -- agent's discretion they may be made read-write so that the
+ -- management station, when appropriately authorized, may
+ -- change the addressing information related to the
+ -- configuration of a logical IP subnetwork implemented on
+ -- top of SMDS.
+
+ -- This table is necessary to support RFC1209 (IP-over-SMDS)
+ -- and gives information on the Group Addresses and ARP
+ -- Addresses used in the Logical IP subnetwork.
+ -- One SMDS address may be associated with multiple IP
+ -- addresses. One SNI may be associated with multiple LISs.
+
+ ipOverSMDSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpOverSMDSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The table of addressing information relevant to
+ this entity's IP addresses."
+ ::= { ipOverSMDS 1 }
+
+ ipOverSMDSEntry OBJECT-TYPE
+ SYNTAX IpOverSMDSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The addressing information for one of this
+ entity's IP addresses."
+ INDEX { ipOverSMDSIndex, ipOverSMDSAddress }
+ ::= { ipOverSMDSTable 1 }
+
+ IpOverSMDSEntry ::=
+ SEQUENCE {
+ ipOverSMDSIndex IfIndex,
+ ipOverSMDSAddress IpAddress,
+ ipOverSMDSHA SMDSAddress,
+ ipOverSMDSLISGA SMDSAddress,
+ ipOverSMDSARPReq SMDSAddress
+ }
+
+ ipOverSMDSIndex OBJECT-TYPE
+
+
+
+Brown & Tesink [Page 21]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the
+ interface for which this entry contains management
+ information. "
+ ::= { ipOverSMDSEntry 1 }
+
+ ipOverSMDSAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address to which this entry's addressing
+ information pertains."
+ ::= { ipOverSMDSEntry 2 }
+
+ ipOverSMDSHA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SMDS Individual address of the IP station."
+ ::= { ipOverSMDSEntry 3 }
+
+ ipOverSMDSLISGA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SMDS Group Address that has been configured
+ to identify the SMDS Subscriber-Network Interfaces
+ (SNIs) of all members of the Logical IP Subnetwork
+ (LIS) connected to the network supporting SMDS."
+ ::= { ipOverSMDSEntry 4 }
+
+ ipOverSMDSARPReq OBJECT-TYPE
+ SYNTAX SMDSAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SMDS address (individual or group) to which
+ ARP Requests are to be sent."
+ ::= { ipOverSMDSEntry 5 }
+
+
+ -- The SMDS Carrier Selection group
+
+
+
+Brown & Tesink [Page 22]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ -- This group is used as a place holder
+ -- for carrier selection objects.
+
+ smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 }
+
+
+ -- The SIP Error Log
+
+ sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }
+
+ sipL3PDUErrorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipL3PDUErrorEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table that contains the latest occurrence of
+ the following syntactical SIP L3PDU errors:
+
+ - Destination Address Field Format Error,
+
+ The following pertains to the 60 least significant
+ bits of the 64 bit address field. The 60 bits
+ contained in the address subfield can be used to
+ represent addresses up to 15 decimal digits. Each
+ decimal digit shall be encoded into four bits
+ using Binary Coded Decimal (BCD), with the most
+ significant digit occurring left-most. If not all
+ 15 digits are required, then the remainder of this
+ field shall be padded on the right with bits set
+ to one. An error is considered to have occurred:
+ a). if the first four bits of the address
+ subfield are not BCD, OR b). if the first four
+ bits of the address subfield are populated with
+ the country code value 0001, AND the 40 bits which
+ follow are not Binary Coded Decimal (BCD) encoded
+ values of the 10 digit addresses, OR the remaining
+ 16 least significant bits are not populated with
+ 1's, OR c). if the address subfield is not
+ correct according to another numbering plan which
+ is dependent upon the carrier assigning the
+ numbers and offering SMDS.
+
+ - Source Address Field Format Error,
+
+ The description of this parameter is the same as
+ the description of the Destination Address Field
+ Format Error.
+
+
+
+
+Brown & Tesink [Page 23]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ - Invalid BAsize Field Value,
+
+ An error is considered to have occurred when the
+ BAsize field of an SIP L3PDU contains a value less
+ that 32, greater than 9220 octets without the
+ CRC32 field present, greater than 9224 octets with
+ the CRC32 field present, or not equal to a
+ multiple of 4 octets,
+
+ - Invalid Header Extension Length Field Value,
+
+ An error is considered to have occurred when the
+ Header Extension Length field value is not equal
+ 3.
+
+ - Invalid Header Extension - Element Length,
+
+ An error is considered to have occurred when the
+ Header Extension - Element Length is greater than
+ 12.
+
+ - Invalid Header Extension - Version Element
+ Position, Length, or Value,
+
+ An error is considered to have occurred when a
+ Version element with Length=3, Type=0, and Value=1
+ does not appear first within the Header Extension,
+ or an element Type=0 appears somewhere other than
+ within the first three octets in the Header
+ Extension.
+
+ - Invalid Header Extension - Carrier Selection
+ Element Position, Length, Value or Format,
+
+ An error is considered to have occurred when a
+ Carrier Selection element does not appear second
+ within the Header Extension, if the Element Type
+ does not equal 1, the Element Length does not
+ equal 4, 6, or 8, the Element Value field is not
+ four BCD encoded decimal digits used in specifying
+ the Carrier Identification Code (CIC), or the
+ identified CIC code is invalid.
+
+ - Header Extension PAD Error
+
+ An error is considered to have occurred when the
+ Header Extension PAD is 9 octets in length, or if
+ the Header Extension PAD is greater than zero
+
+
+
+Brown & Tesink [Page 24]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ octets in length and the Header Extension PAD does
+ not follow all Header Extension elements or does
+ not begin with at least one octet of all zeros.
+
+ - BEtag Mismatch Error,
+
+ An error is considered to have occurred when the
+ Beginning-End Tags in the SIP L3PDU header and
+ trailer are not equal.
+
+ - BAsize Field not equal to Length Field Error,
+
+ An error is considered to have occurred when the
+ value of the BAsize Field does not equal the value
+ of the Length Field.
+
+ - Incorrect Length Error, and
+
+ An error is considered to have occurred when the
+ the Length field value is not equal to the portion
+ of the SIP L3PDU which extends from the
+ Destination Address field up to and including the
+ CRC32 field (if present) or up to and including
+ the PAD field (if the CRC32 field is not present).
+ As an optional check, an error is considered to
+ have occurred when the length of a partially
+ received SIP L3PDU exceeds the BAsize value.
+
+ - MRI Timeout Error.
+
+ An error is considered to have occurred when the
+ elapsed time between receipt of BOM and
+ corresponding EOM exceeds the value of the MRI
+ (Message Receive Interval) for a particular
+ transport signal format.
+
+ An entry is indexed by interface number and error
+ type, and contains Source Address, Destination
+ Address and a timestamp. All these errors are
+ counted in the sipL3Errors counter. When
+ sipL3PDUErrorTimeStamp is equal to zero, the
+ SipL3PDUErrorEntry does not contain any valid
+ information."
+ ::= { sipErrorLog 1 }
+
+ sipL3PDUErrorEntry OBJECT-TYPE
+ SYNTAX SipL3PDUErrorEntry
+ MAX-ACCESS not-accessible
+
+
+
+Brown & Tesink [Page 25]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ STATUS current
+ DESCRIPTION
+ "An entry in the service disagreement table."
+ INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType }
+ ::= { sipL3PDUErrorTable 1 }
+
+ SipL3PDUErrorEntry ::= SEQUENCE {
+ sipL3PDUErrorIndex IfIndex,
+ sipL3PDUErrorType INTEGER,
+ sipL3PDUErrorSA SMDSAddress,
+ sipL3PDUErrorDA SMDSAddress,
+ sipL3PDUErrorTimeStamp TimeStamp
+ }
+
+ sipL3PDUErrorIndex OBJECT-TYPE
+ SYNTAX IfIndex
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the
+ interface for which this entry contains management
+ information."
+ ::= { sipL3PDUErrorEntry 1 }
+
+ sipL3PDUErrorType OBJECT-TYPE
+ SYNTAX INTEGER {
+ erroredDAFieldFormat (1),
+ erroredSAFieldFormat (2),
+ invalidBAsizeFieldValue (3),
+ invalidHdrExtLength (4),
+ invalidHdrExtElementLength (5),
+ invalidHdrExtVersionElementPositionLenthOrValue (6),
+ invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7),
+ hePADError (8),
+ beTagMismatch (9),
+ baSizeFieldNotEqualToLengthField (10),
+ incorrectLength (11),
+ mriTimeout (12)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of error."
+ ::= { sipL3PDUErrorEntry 2 }
+
+ sipL3PDUErrorSA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ MAX-ACCESS read-only
+
+
+
+Brown & Tesink [Page 26]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ STATUS current
+ DESCRIPTION
+ "A rejected SMDS source address."
+ ::= { sipL3PDUErrorEntry 3 }
+
+ sipL3PDUErrorDA OBJECT-TYPE
+ SYNTAX SMDSAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A rejected SMDS destination address."
+ ::= { sipL3PDUErrorEntry 4 }
+
+ sipL3PDUErrorTimeStamp OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The timestamp for the service disagreement. The
+ timestamp contains the value of sysUpTime at the
+ latest occurrence of this type of service
+ disagreement. See textual description under
+ sipL3PDUErrorTable for boundary conditions."
+ ::= { sipL3PDUErrorEntry 5 }
+
+
+ -- The DXI Group
+
+ sipDxiTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SipDxiEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The DXI table."
+ ::= { sipMIBObjects 1 }
+
+ sipDxiEntry OBJECT-TYPE
+ SYNTAX SipDxiEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the DXI table."
+ INDEX { ifIndex }
+ ::= { sipDxiTable 1 }
+
+ SipDxiEntry ::=
+ SEQUENCE {
+ sipDxiCrc
+
+
+
+Brown & Tesink [Page 27]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ INTEGER,
+ sipDxiOutDiscards
+ Counter32,
+ sipDxiInErrors
+ Counter32,
+ sipDxiInAborts
+ Counter32,
+ sipDxiInTestFrames
+ Counter32,
+ sipDxiOutTestFrames
+ Counter32,
+ sipDxiHbpNoAcks
+ Counter32
+ }
+
+ sipDxiCrc OBJECT-TYPE
+ SYNTAX INTEGER {
+ crc16(1),
+ crc32(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object indicates the type
+ of Frame Checksum used by DXI. Current
+ choices include CCITT CRC16 or CRC32."
+ ::= { sipDxiEntry 1 }
+
+ sipDxiOutDiscards OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of outbound frames discarded
+ because of congestion."
+ ::= { sipDxiEntry 2 }
+
+ sipDxiInErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of inbound frames discarded
+ because of errors such as frame checksum
+ (CRC) violations,
+ non-integral number of octets, address
+ and control field violations, and frame
+ size errors."
+
+
+
+Brown & Tesink [Page 28]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ ::= { sipDxiEntry 3 }
+
+ sipDxiInAborts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of inbound frames discarded
+ because of an abort bit sequence (1111111)
+ received before closing flag."
+ ::= { sipDxiEntry 4 }
+
+ sipDxiInTestFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of unerrored,
+ inbound Test frames received
+ (generally as part of Heart
+ Beat Poll procedure)."
+ ::= { sipDxiEntry 5 }
+
+ sipDxiOutTestFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of unerrored,
+ outbound Test frames sent
+ (generally as part of Heart
+ Beat Poll procedure)."
+ ::= { sipDxiEntry 6 }
+
+ sipDxiHbpNoAcks OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Heart Beat
+ Poll (HBP) No Ack timeouts."
+ ::= { sipDxiEntry 7 }
+
+
+ -- conformance information
+
+ smdsConformance OBJECT IDENTIFIER ::= { sipMIB 2 }
+
+
+
+
+Brown & Tesink [Page 29]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ smdsGroups OBJECT IDENTIFIER ::= { smdsConformance 1 }
+ smdsCompliances OBJECT IDENTIFIER ::= { smdsConformance 2 }
+
+
+ -- compliance statements
+
+ smdsCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SMDS interfaces."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { sipLevel3Stuff }
+
+ GROUP sipLevel2Stuff
+ DESCRIPTION
+ "This group is mandatory only for those
+ interfaces (SNIs) which run SIP Level 2."
+
+ GROUP sipDS1PLCPStuff
+ DESCRIPTION
+ "This group is mandatory only for those
+ interfaces (SNIs) which run the DS1 PLCP."
+
+ GROUP sipDS3PLCPStuff
+ DESCRIPTION
+ "This group is mandatory only for those
+ interfaces (SNIs) which run the DS3 PLCP."
+
+ GROUP sipIPApplicationsStuff
+ DESCRIPTION
+ "This group is mandatory only for interfaces
+ operating IP over SMDS in accordance with
+ RFC1209."
+
+ GROUP sipDxiStuff
+ DESCRIPTION
+ "This group is mandatory only for those interfaces
+ (DXI-SNI)
+ which run the DXI protocol."
+ ::= { smdsCompliances 1 }
+
+ -- units of conformance
+
+ sipLevel3Stuff OBJECT-GROUP
+ OBJECTS { sipL3Index,
+ sipL3VersionSupport, sipL3PDUErrorIndex,
+ sipL3PDUErrorType,
+
+
+
+Brown & Tesink [Page 30]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipL3PDUErrorSA, sipL3PDUErrorDA,
+ sipL3PDUErrorTimeStamp }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ applicable to all SMDS interfaces."
+ ::= { smdsGroups 1 }
+
+ sipLevel2Stuff OBJECT-GROUP
+ OBJECTS { sipL2Index, sipL2HcsOrCRCErrors,
+ sipL2PayloadLengthErrors,
+ sipL2SequenceNumberErrors,
+ sipL2MidCurrentlyActiveErrors,
+ sipL2BomOrSSMsMIDErrors,
+ sipL2EomsMIDErrors }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ specific to interfaces using the SIP Level 2."
+ ::= { smdsGroups 2 }
+
+ sipDS1PLCPStuff OBJECT-GROUP
+ OBJECTS { sipDS1PLCPIndex, sipDS1PLCPSEFSs,
+ sipDS1PLCPAlarmState, sipDS1PLCPUASs }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ specific to interfaces using the DS1 PLCP."
+ ::= { smdsGroups 3 }
+
+ sipDS3PLCPStuff OBJECT-GROUP
+ OBJECTS { sipDS3PLCPIndex, sipDS3PLCPSEFSs,
+ sipDS3PLCPAlarmState, sipDS3PLCPUASs }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ specific to interfaces using the DS3 PLCP."
+ ::= { smdsGroups 4 }
+
+
+ sipIPApplicationsStuff OBJECT-GROUP
+ OBJECTS { ipOverSMDSIndex, ipOverSMDSAddress,
+ ipOverSMDSHA, ipOverSMDSLISGA, ipOverSMDSARPReq }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ for running IP over SMDS."
+ ::= { smdsGroups 5 }
+
+
+
+Brown & Tesink [Page 31]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ sipDxiStuff OBJECT-GROUP
+ OBJECTS { sipDxiCrc, sipDxiOutDiscards,
+ sipDxiInErrors, sipDxiInAborts,
+ sipDxiInTestFrames, sipDxiOutTestFrames,
+ sipDxiHbpNoAcks }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing information
+ specific to interfaces using the DXI protocol."
+ ::= { smdsGroups 6 }
+
+ END
+
+5. Acknowledgments
+
+ This specification is a product of the ifMIB Working Group.
+
+6. References
+
+ [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure
+ of Management Information for version 2 of the Simple Network
+ Management Protocol (SNMPv2)", RFC 1442, SNMP Research, Inc.,
+ Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon
+ University, April 1993.
+
+ [2] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Textual
+ Conventions for version 2 of the the Simple Network Management
+ Protocol (SNMPv2)", RFC 1443, SNMP Research, Inc., Hughes LAN
+ Systems, Dover Beach Consulting, Inc., Carnegie Mellon
+ University, April 1993.
+
+ [3] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
+ "Conformance Statements for version 2 of the the Simple Network
+ Management Protocol (SNMPv2)", RFC 1444, SNMP Research, Inc.,
+ Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon
+ University, April 1993.
+
+ [4] Galvin, J., and K. McCloghrie, "Administrative Model for version
+ 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,
+ Trusted Information Systems, Hughes LAN Systems, April 1993.
+
+ [5] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol
+ Operations for version 2 of the Simple Network Management
+ Protocol (SNMPv2)", RFC 1448, SNMP Research, Inc., Hughes LAN
+ Systems, Dover Beach Consulting, Inc., Carnegie Mellon
+ University, April 1993.
+
+
+
+
+
+Brown & Tesink [Page 32]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ [6] McCloghrie, K., and M. Rose, Editors, "Management Information
+ Base for Network Management of TCP/IP-based internets: MIB-II",
+ STD 17, RFC 1213, Hughes LAN Systems, Inc., Performance Systems
+ International, March 1991.
+
+ [7] Information processing systems - Open Systems Interconnection -
+ Specification of Abstract Syntax Notation One (ASN.1),
+ International Organization for Standardization. International
+ Standard 8824, December 1987.
+
+ [8] Information processing systems - Open Systems Interconnection -
+ Specification of Basic Encoding Rules for Abstract Notation One
+ (ASN.1), International Organization for Standardization.
+ International Standard 8825, December 1987.
+
+ [9] McCloghrie, K., and F. Kastenholz, "Evolution of Interfaces Group
+ of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software, January
+ 1994.
+
+ [10] Cox, T., and K. Tesink, Editors, "Definitions of Managed Objects
+ for the DS3/E3 Interface Type", RFC 1407, Bellcore, January 1993.
+
+ [11] Baker, F., and J. Watt, Editors, "Definitions of Managed Objects
+ for the DS1/E1 Interface Type", RFC 1406, Advanced Computer
+ Communications, Newbridge Networks Corporation, January 1993.
+
+ [12] Cox, T., and K. Tesink, Editors, "Definition of Managed Objects
+ for the SMDS Interface Type", RFC 1304, Bellcore, February 1992.
+
+ [13] "Generic System Requirements in Support of Switched Multi-megabit
+ Data Service", Bellcore Technical Reference, TR-TSV-000772, Issue
+ 1, May 1991.
+
+ [14] "Local Access System Generic Requirements, Objectives, and
+ Interfaces in Support of Switched Multi-megabit Data Service",
+ Bellcore Technical Reference, TR-TSV-000773, Issue 1, June 1990.
+
+ [15] Piscitello, D., and J. Lawrence, Editors, The Transmission of IP
+ Datagrams over the SMDS Service", RFC 1209, Bell Communications
+ Research, March 1991.
+
+ [16] "Generic Requirements For SMDS Customer Network Management
+ Service", Bellcore TR-TSV-001062, Issue 1, March 1993, and
+ Supplement 1, December 1993.
+
+ [17] Cox, R., and K. Tesink, "Definitions of Managed Objects for SMDS
+ Subscription", Version 2.1, Bellcore, August 1992.
+
+
+
+
+Brown & Tesink [Page 33]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+ [18] Frame Based Interface Protocol for SMDS Networks - Data Exchange
+ Interface / Subscriber Network Interface Revision 1.0 - SMDS
+ Interest Group SIG-TS-005/1993, February 2, 1993.
+
+ [19] Frame Based Interface Protocol for SMDS Networks - SIP Relay
+ Interface Revision 1.0 - SMDS Interest Group SIG-TS-006/1993,
+ February 2, 1993.
+
+ [20] "Generic Requirements For Low Speed SMDS Access", Bellcore TR-
+ TSV-001239, Issue 1, December 1993.
+
+ [21] ATM Forum, "ATM User Network Interface Specification", Version
+ 3.0, September 1993.
+
+ [22] Ahmed, M., and K. Tesink, Editors, "Definitions of Managed
+ Objects for ATM Management", RFC 1695, Bellcore, August 1994.
+
+ [23] Brown, R., Editor, "Definitions of Managed Objects for Frame
+ Relay Service", RFC 1604, Bellcore, March 1994.
+
+ [24] Specification for Implementation of SMDS over an ATM-based Public
+ UNI - Cedric Druce, Max Figueroa, Bellcore - SIG TWG-1993/043,
+ SMDS Interest Group Technical Working Group, Work in Progress,
+ August 24, 1993.
+
+ [25] Brown, T. and K. Tesink, Editors), "Definitions of Managed
+ Objects for the SONET Interface Type, RFC 1595, Bellcore, March
+ 1994.
+
+7. Security Considerations
+
+ Security issues are not discussed in this memo.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Brown & Tesink [Page 34]
+
+RFC 1694 SMDS Interface Objects August 1994
+
+
+8. Authors' Addresses
+
+ Tracy A. Brown
+ Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+
+ Phone: (908) 758-2107
+ EMail: tacox@mail.bellcore.com
+
+
+ Kaj Tesink
+ Bell Communications Research
+ 331 Newman Springs Road
+ P.O. Box 7020
+ Red Bank, NJ 07701-7020
+
+ Phone: (908) 758-5254
+ EMail: kaj@cc.bellcore.com
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+