diff options
author | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
---|---|---|
committer | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
commit | 4bfd864f10b68b71482b35c818559068ef8d5797 (patch) | |
tree | e3989f47a7994642eb325063d46e8f08ffa681dc /doc/rfc/rfc1747.txt | |
parent | ea76e11061bda059ae9f9ad130a9895cc85607db (diff) |
doc: Add RFC documents
Diffstat (limited to 'doc/rfc/rfc1747.txt')
-rw-r--r-- | doc/rfc/rfc1747.txt | 3755 |
1 files changed, 3755 insertions, 0 deletions
diff --git a/doc/rfc/rfc1747.txt b/doc/rfc/rfc1747.txt new file mode 100644 index 0000000..8cc6366 --- /dev/null +++ b/doc/rfc/rfc1747.txt @@ -0,0 +1,3755 @@ + + + + + + +Network Working Group J. Hilgeman, Chair +Request for Comments: 1747 Apertus Technologies, Inc. +Category: Standards Track S. Nix + Metaplex, Inc. + A. Bartky + Sync Research, Inc. + W. Clark, Editor + cisco Systems, Inc. + January 1995 + + + Definitions of Managed Objects for SNA Data Link Control (SDLC) + using SMIv2 + +Status of this Memo + + This document specifies an Internet standards track protocol for the + Internet community, and requests discussion and suggestions for + improvements. Please refer to the current edition of the "Internet + Official Protocol Standards" (STD 1) for the standardization state + and status of this protocol. Distribution of this memo is unlimited. + +Abstract + + This specification defines an extension to the Management Information + Base (MIB) for use with SNMP-based network management. In + particular, it defines objects for managing the configuration, + monitoring and control of data link controls in an SNA environment. + This draft identifies managed objects for SNA Synchronous Data Link + Control (SDLC) links only. + +Table of Contents + + 1. The SNMPv2 Network Management Framework ................. 2 + 1.1 Object Definitions .................................... 2 + 2. Overview ................................................ 2 + 2.1 Tables Defined in the SNADLC SDLC MIB ................. 3 + 2.2 Row Creation Mechanism ................................ 3 + 2.3 Relationship to the Interfaces Group .................. 4 + 3. Definitions ............................................. 7 + 3.1 Port Administrative Table ............................. 9 + 3.2 Port Operational Table ............................... 14 + 3.3 Port Statistics Table ................................ 20 + 3.4 Link Station Administrative Table .................... 26 + 3.5 Link Station Operational Table ....................... 35 + 3.6 Link Station Statistics Table ........................ 44 + 3.7 Trap Definitions ..................................... 56 + 3.8 Compliance Statements ................................ 57 + + + +Hilgeman, Nix, Bartky & Clark [Page 1] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + 4. Acknowledgments ........................................ 65 + 5. References ............................................. 65 + 6. Glossary ............................................... 66 + 7. Security Considerations ................................ 67 + 8. Authors' Addresses ..................................... 67 + +1. The SNMPv2 Network Management Framework + + The SNMPv2 Network Management Framework consists of four major + components. They are: + + o RFC 1441 which defines the SMI, the mechanisms used for + describing and naming objects for the purpose of management. + + o STD 17, RFC 1213 defines MIB-II, the core set of managed + objects for the Internet suite of protocols. + + o RFC 1445 which defines the administrative and other + architectural aspects of the framework. + + o RFC 1448 which defines the protocol used for network access + to managed objects. + + The Framework permits new objects to be defined for the purpose of + experimentation and evaluation. + +1.1. Object Definitions + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. Objects in the MIB are + defined using the subset of Abstract Syntax Notation One (ASN.1) + defined in the SMI. In particular, each object object type is named + by an OBJECT IDENTIFIER, an administratively assigned name. The + object type together with an object instance serves to uniquely + identify a specific instantiation of the object. For human + convenience, we often use a textual string, termed the descriptor, to + refer to the object type. + +2. Overview + + This memo identifies the proposed set of objects for configuring, + monitoring, and controlling SDLC ports and link stations. + + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 2] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +2.1. Tables Defined in the SNADLC SDLC MIB + + The SNADLC MIB is composed of two managed entities with three tables + each. The two managed entities for SDLC are: + + o Ports: the physical connection, and + + o Link Stations: the logical connections on the Port. + + The three management tables are: + + o Adminstration: objects used for configuring and controlling + the operation of a Port or Link Station, + + o Operational: objects that reflect the run-time state of the + Port or Link Station, and + + o Statistics: objects that reflect the operating metrics of the + Port or Link Station. + + Considering the above combinations, the following are the actual + tables found in this MIB: + + 1) Port Administration Table, + + 2) Port Operation Table, + + 3) Port Statistics Table, + + 4) Link Station Administration Table, + + 5) Link Station Operation Table, + + 6) Link Station Statistics Table. + + All variables in this MIB relate to SDLC ports and link stations + only. Any variable relating to higher-layer entities in SNA such as + Physical Units (PU) and Logical Units (LU) are found in the SNA NAU + MIB [4]. + +2.2. Row Creation Mechanism + + Row creation mechanism for the sdlcLSAdminTable is based on the use + of the RowStatus object. It follows the rules for the use in SNMPv1 + context proposed in the memo "Row creation with SNMPv1" [5]. Before + accepting the destroy value for an entry, an agent has to verify the + operational state of the corresponding entry in the sdlcLSOperTable + entry. + + + +Hilgeman, Nix, Bartky & Clark [Page 3] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +2.3. Relationship to the Interfaces Group + + This memo shall conform to the recommendations of [6]. + + The SDLC layer of each SDLC Port shall be modeled by a row in the + ifTable with an ifType using the IANA assigned number for SDLC (17). + Each SDLC port interface must comply with the following conformance + groups in [6]: + + - ifGeneralGroup + - ifStackGroup + - ifPacketGroup + + An implementation may optionally comply with the ifTestGroup defined + in that memo to execute vendor specific tests. An example of this + would be to perform LPDA test functions. + + The SDLC port's relation with its physical, or lower-layer interface + (i.e., RS-232, V.35, etc.) shall be modeled by a row in the + ifStackTable with the ifStackHigherLayer pointing to the SDLC port + ifTable instance and the ifStackLowerLayer pointing to the physical + media-specific ifTable instance. The media-specific objects of these + lower-layer interfaces will, of course, be described in their + respective MIBs (i.e., [1]). + + The following table provides specific implementation guidelines for + all the interface group objects listed in the conformance tables + above. + +Object Use for an SDLC Port + +ifIndex Each SDLC port is represented by an ifEntry. All + SDLC port tables shall be indexed by ifIndex. + +ifDescr Description of the SDLC port. + +ifType The IANA value reserved for SDLC - 17. + +ifMtu Refer to [6]. + +ifSpeed This object shall reflect the value of the + corresponding object in the ifEntry of the + associated lower-layer interface. + +ifPhysAddress A string denoting the physical location of the SDLC + port within its node. This shall have unique + significance within each implementing node. + + + + +Hilgeman, Nix, Bartky & Clark [Page 4] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +ifAdminStatus This object shall reflect the value of the + corresponding object in the ifEntry of the + associated lower-layer interface. + +ifOperStatus This object shall reflect the value of the + corresponding object in the ifEntry of the + associated lower-layer interface. + +ifLastChange Refer to [6]. + +ifInOctets Refer to [6]. + +ifInUcastPkts This object shall count packets received from a + specific SDLC poll address. Packets for the SDLC + broadcast address of x'FF' are not counted. + +ifInDiscards Refer to [6]. + +ifInErrors Refer to [6]. Specific counters for these errors + are kept in the sdlcPortStatsTable. + +ifInUnknownProtos This counter shall return zero for SDLC ports. + +ifOutOctets Refer to [6]. + +ifOutUcastPkts This object shall count packets transmitted to a + specific SDLC poll address (not x'FF'). + +ifOutDiscards Refer to [6]. + +ifOutErrors Refer to [6]. Specific counters for these errors + are kept in the sdlcPortStatsTable. + +ifName The textual name of the SDLC port or an octet string + of zero length. + +ifInMulticastPkts The value is 0 (not applicable to the SDLC layer). + +ifInBroadcastPkts This object shall count packets received on this + interface addressed to the SDLC broadcast address + (x'FF'). Only point-to-point ports supporting a + secondary switched station should return non-zero + values. + +ifOutMulticastPkts The value is 0 (not applicable to the SDLC layer). + +ifOutBroadcastPkts This object shall count packets transmitted on this + interface which were addressed to the SDLC broadcast + + + +Hilgeman, Nix, Bartky & Clark [Page 5] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + address (x'FF'). Only point-to-point ports + supporting a primary switched station should + return non-zero values. + +ifHC* Not part of the conformance group. + +ifLinkUpDownTrapEnable + Refer to [6]. Default is disabled (2). + +ifHighSpeed Refer to [6]. + +ifPromiscuousMode Should return false if this interface receives only + packets addressed to its SDLC poll address(es). + However, in certain implementations, the lower-layer + interface shall present all frames to the SDLC port + regardless of the poll address. Such frames may be + the result of a misconfigured peer or the secondary + end of a multipoint connection. Such + implementations should return true for this + object. + +ifConnectorPresent Set to 'false'. + +ifStackHigherLayer For each SDLC port there will be an ifStackEntry + with this object's value referring to the ifIndex of + the SDLC port's ifEntry for the SDLC layer. + +ifStackLowerLayer For each SDLC port there will be an ifStackEntry + with this object's value referring to the ifIndex of + the physical layer interface's ifEntry for that SDLC + port. + +ifStackStatus Refer to [6]. + + + + + + + + + + + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 6] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +3. Definitions + +SNA-SDLC-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Counter32, Integer32, TimeTicks + FROM SNMPv2-SMI + DisplayString, RowStatus, TimeInterval + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF + mib-2, ifIndex, ifAdminStatus, ifOperStatus + FROM RFC1213-MIB; + + +snaDLC MODULE-IDENTITY + LAST-UPDATED "9411150000Z" + ORGANIZATION "IETF SNA DLC MIB Working Group" + CONTACT-INFO + " Wayne Clark + + Postal: cisco Systems, Inc. + 3100 Smoketree Ct. + Suite 1000 + Raleigh, NC 27604 + US + + Tel: +1 919 878 6958 + + E-Mail: wclark@cisco.com" + + DESCRIPTION + "This is the MIB module for objects used to + manage SDLC devices." + +::= { mib-2 41 } + +-- +-- The following data link controls are modelled in this MIB module: +-- +-- 1. SDLC +-- + +sdlc OBJECT IDENTIFIER ::= { snaDLC 1 } + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 7] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +-- +-- THE SDLC GROUP +-- ============== +-- +-- The following resources are modelled in the SDLC group of this +-- MIB module: +-- +-- 1. PORTS +-- 2. LINK STATIONS + +sdlcPortGroup OBJECT IDENTIFIER ::= { sdlc 1 } -- Physical Ports +sdlcLSGroup OBJECT IDENTIFIER ::= { sdlc 2 } -- Logical Link Stations + +-- +-- THE SDLC PORT GROUP +-- =================== +-- +-- The following classes of information is modelled for each SDLC port: +-- +-- 1. ADMINISTRATIVE ( read/write) +-- 2. OPERATIONAL ( read-only) +-- 3. STATISTICS ( read-only) + +-- Information not found in this group is found in tables described in +-- the following RFCs: +-- +-- 1. RFC1213 - MIB-II +-- +-- TABLE INDEX +-- ==================== ==================== +-- a. ifTable ifIndex +-- +-- 2. RFC1659 - The RS232-like MIB +-- +-- TABLE INDEX +-- ==================== ==================== +-- a. rs232PortTable rs232PortIndex +-- b. rs232SyncPortTable rs232SyncPortIndex +-- c. rs232InSigTable rs232InSigPortIndex, +-- rs232InSigName +-- d. rs232OutSigTable rs232OutSigPortIndex, +-- rs232OutSigName +-- ** e. rs232AsyncPortTable rs232AsyncPortIndex +-- +-- ** rs232AsyncPortTable for ISO 3309.3 ( Start-Stop SDLC). + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 8] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +-- ************************************************************* +-- * * +-- * THE SDLC PORT ADMINISTRATIVE TABLE * +-- * * +-- ************************************************************* + +sdlcPortAdminTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcPortAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects that can be + changed to manage an SDLC port. Changing one + of these parameters may take effect in the + operating port immediately or may wait until + the interface is restarted depending on the + details of the implementation. + + Most of the objects in this read-write table + have corresponding read-only objects in the + sdlcPortOperTable that return the current + operating value. + + The operating values may be different from + these configured values if a configured + parameter was changed after the interface was + started." + ::= { sdlcPortGroup 1 } + +sdlcPortAdminEntry OBJECT-TYPE + SYNTAX SdlcPortAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configured values for an SDLC port." + INDEX { ifIndex } + ::= { sdlcPortAdminTable 1 } + +SdlcPortAdminEntry ::= SEQUENCE +{ + sdlcPortAdminName DisplayString, + sdlcPortAdminRole INTEGER, + sdlcPortAdminType INTEGER, + sdlcPortAdminTopology INTEGER, + sdlcPortAdminISTATUS INTEGER, + sdlcPortAdminACTIVTO TimeInterval, + sdlcPortAdminPAUSE TimeInterval, + sdlcPortAdminSERVLIM Integer32, + + + +Hilgeman, Nix, Bartky & Clark [Page 9] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + sdlcPortAdminSlowPollTimer TimeInterval +} + +sdlcPortAdminName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..10)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "An octet string that defines the physical port + to which this interface is assigned. It has + implementation-specific significance. Its value + shall be unique within the administered + system. It must contain only ASCII printable + characters. Should an implementation choose to + accept a write operation for this object, it + causes the logical port definition associated + with the table instance to be moved to a + different physical port. A write operation + shall not take effect until the port is cycled + inactive." + ::= { sdlcPortAdminEntry 1 } + +sdlcPortAdminRole OBJECT-TYPE + SYNTAX INTEGER + { + primary(1), + secondary(2), + negotiable(3) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object describes the role that the link + station shall assume the next time a connection + is established. + + Even though this is defined as a port object, + it is a link station attribute in the sense + that a role is per link station. However, it + is not possible to vary link station roles on a + particular port. For example, if an SDLC port + is configured to primary, all link stations on + that port must be primary." + ::= { sdlcPortAdminEntry 2 } + +sdlcPortAdminType OBJECT-TYPE + SYNTAX INTEGER + { + + + +Hilgeman, Nix, Bartky & Clark [Page 10] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + leased(1), + switched(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter defines whether the SDLC port + is to connect to a leased or switched line. A + write operation to this administrative value + shall not take effect until the SDLC port has + been cycled inactive." + DEFVAL { leased } + ::= { sdlcPortAdminEntry 3 } + +sdlcPortAdminTopology OBJECT-TYPE + SYNTAX INTEGER + { + pointToPoint(1), + multipoint(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter defines whether the SDLC port is + capable of operating in either a point-to-point + or multipoint topology. + + sdlcPortAdminTopology == multipoint implies the + port can also operate in a point-to-point + topology. sdlcPortAdminTopology == + pointToPoint does not imply the port can + operate in a multipoint topology. + + A write operation to this administrative value + shall not take effect until the SDLC port has + been cycled inactive." + DEFVAL { pointToPoint } + ::= { sdlcPortAdminEntry 4 } + +sdlcPortAdminISTATUS OBJECT-TYPE + SYNTAX INTEGER + { + inactive(1), + active(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 11] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "This parameter controls the initial value of + the administrative status, ifAdminStatus, of + this SDLC port at port start-up. Depending + on the implementation, a write operation to + this administrative object may not take effect + until the SDLC port has been cycled inactive." + DEFVAL { active } + ::= { sdlcPortAdminEntry 5 } + +sdlcPortAdminACTIVTO OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This parameter defines the period of time (in + 1/100ths of a second) that the port will allow a + switched line to remain inactive before + disconnecting. A switched line is considered + to be inactive if there are no I-Frames being + transferred. A value of zero indicates no + timeout. Depending on the implementation, a + write operation to this administered value may + not take effect until the port is cycled + inactive. + + This object only has meaning for SDLC ports + where sdlcPortAdminType == switched + + The object descriptor contains the name of an + NCP configuration parameter, ACTIVTO. Please + note that the value of this object represents + 1/100ths of a second while the NCP ACTIVTO is + represented in seconds." + DEFVAL { 0 } + ::= { sdlcPortAdminEntry 6 } + +sdlcPortAdminPAUSE OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object defines the minimum elapsed time + (in 1/100ths of a second) between any two + traversals of the poll list for a primary SDLC + port. Depending on the implementation, a write + operation to this administered value may not + take effect until the port is cycled inactive. + + + + +Hilgeman, Nix, Bartky & Clark [Page 12] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + The object descriptor contains the name of an + NCP configuration parameter, PAUSE. Please + note that the value of this object represents + 1/100ths of a second while the NCP PAUSE is + represented in 1/10ths of a second. + + This object only has meaning for SDLC ports + where sdlcPortAdminRole == primary " + DEFVAL { 200 } + ::= { sdlcPortAdminEntry 7 } + +sdlcPortAdminSERVLIM OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object defines the number of times the + active poll list will be traversed before + polling a station on the slow poll list for a + primary, multipoint SDLC port. Depending on + the implementation, a write operation to this + administered value may not take effect until + the port is cycled inactive. + + This object only has meaning for SDLC ports + where + sdlcPortAdminRole == primary + and + sdlcPortAdminTopology == multipoint " + DEFVAL { 20 } + ::= { sdlcPortAdminEntry 8 } + +sdlcPortAdminSlowPollTimer OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object describes the elapsed time (in + 1/100ths of a second) between polls for failed + secondary link station addresses. Depending + on the implementation, a write operation to + this administered value may not take effect + until the port is cycled inactive. + + This object only has meaning for SDLC ports + where + sdlcPortAdminRole == primary + and + + + +Hilgeman, Nix, Bartky & Clark [Page 13] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + sdlcPortAdminTopology == multipoint " + DEFVAL { 2000 } + ::= { sdlcPortAdminEntry 9 } + +-- ************************************************************* +-- * * +-- * THE SDLC PORT OPERATIONAL TABLE * +-- * * +-- ************************************************************* + +sdlcPortOperTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcPortOperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains current SDLC port + parameters. Many of these objects have + corresponding objects inthe sdlcPortAdminTable." + ::= { sdlcPortGroup 2 } + +sdlcPortOperEntry OBJECT-TYPE + SYNTAX SdlcPortOperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Currently set parameters for a specific SDLC + port." + INDEX { ifIndex } + ::= { sdlcPortOperTable 1 } + +SdlcPortOperEntry ::= SEQUENCE +{ + sdlcPortOperName DisplayString, + sdlcPortOperRole INTEGER, + sdlcPortOperType INTEGER, + sdlcPortOperTopology INTEGER, + sdlcPortOperISTATUS INTEGER, + sdlcPortOperACTIVTO TimeInterval, + sdlcPortOperPAUSE TimeInterval, + sdlcPortOperSlowPollMethod INTEGER, + sdlcPortOperSERVLIM Integer32, + sdlcPortOperSlowPollTimer TimeInterval, + sdlcPortOperLastModifyTime TimeTicks, + sdlcPortOperLastFailTime TimeTicks, + sdlcPortOperLastFailCause INTEGER +} + +sdlcPortOperName OBJECT-TYPE + + + +Hilgeman, Nix, Bartky & Clark [Page 14] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + SYNTAX DisplayString (SIZE (1..8)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An octet string that describes the physical + port to which this interface is currently + attached. It has implementation-specific + significance." + ::= { sdlcPortOperEntry 1 } + +sdlcPortOperRole OBJECT-TYPE + SYNTAX INTEGER + { + primary(1), + secondary(2), + undefined(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the role that the link + station has assumed on this connection. + + Even though this is defined as a port object, + it is a link station attribute in the sense + that a role is per link station. However, it + is not possible to vary link station roles on a + particular port. For example, if an SDLC port + is configured to primary, all link stations on + that port must be primary. + + The value of sdlcPortOperRole is undefined(3) + whenever the link station role has not yet been + established by the mode setting command." + ::= { sdlcPortOperEntry 2 } + +sdlcPortOperType OBJECT-TYPE + SYNTAX INTEGER + { + leased(1), + switched(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter defines whether the SDLC port + is currently operating as though connected to a + leased or switched line." + + + +Hilgeman, Nix, Bartky & Clark [Page 15] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + ::= { sdlcPortOperEntry 3 } + +sdlcPortOperTopology OBJECT-TYPE + SYNTAX INTEGER + { + pointToPoint(1), + multipoint(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter defines whether the SDLC port is + currently operating in a point-to-point or + multipoint topology." + ::= { sdlcPortOperEntry 4 } + +sdlcPortOperISTATUS OBJECT-TYPE + SYNTAX INTEGER + { + inactive(1), + active(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter describes the initial value of + the administrative status, ifAdminStatus, of + this SDLC port at last port start-up." + ::= { sdlcPortOperEntry 5 } + + +sdlcPortOperACTIVTO OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This parameter defines the period of time (in + 100ths of a second) that the port will allow a + switched line to remain inactive before + disconnecting. A switched line is considered + to be inactive if there are no I-Frames being + transferred. + + The object descriptor contains the name of an + NCP configuration parameter, ACTIVTO. Please + note that the value of this object represents + 1/100ths of a second while the NCP ACTIVTO is + represented in seconds. + + + +Hilgeman, Nix, Bartky & Clark [Page 16] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + A value of zero indicates no timeout." + ::= { sdlcPortOperEntry 6 } + +sdlcPortOperPAUSE OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the current minimum + elapsed time (in 1/100ths of a second) between + any two traversals of the poll list for a + primary SDLC port. + + The object descriptor contains the name of an + NCP configuration parameter, PAUSE. Please + note that the value of this object represents + 1/100ths of a second while the NCP PAUSE is + represented in 1/10ths of a second. + + This object only has meaning for SDLC ports + where + sdlcPortAdminRole == primary " + ::= { sdlcPortOperEntry 7 } + +sdlcPortOperSlowPollMethod OBJECT-TYPE + SYNTAX INTEGER + { + servlim(1), + pollpause(2), + other(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object defines the exact method that is in + effect for periodically polling failed secondary + link station addresses. + + If sdlcPortOperSlowPollMethod == servlim, then + sdlcPortOperSERVLIM defines the actual polling + characteristics. + + If sdlcPortOperSlowPollMethod == pollpause, + then sdlcPortOperSlowPollTimer defines the + actual polling characteristics. + + If sdlcPortOperSlowPollMethod == other, then + the polling characteristics are modeled in + + + +Hilgeman, Nix, Bartky & Clark [Page 17] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + vendor-specific objects. + + This object only has meaning for SDLC ports + where + sdlcPortOperRole == primary + and + sdlcPortOperTopology == multipoint " + ::= { sdlcPortOperEntry 8 } + +sdlcPortOperSERVLIM OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the number of times the + active poll list is currently being traversed + before polling a station on the slow poll list + for a primary, multipoint SDLC port. + + This object only has meaning for SDLC ports + where + sdlcPortOperRole == primary + and + sdlcPortOperTopology == multipoint " + ::= { sdlcPortOperEntry 9 } + +sdlcPortOperSlowPollTimer OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the elapsed time (in + 1/100ths of a second) between polls for failed + secondary link station addresses. + + This object only has meaning for SDLC ports + where + sdlcPortOperRole == primary + and + sdlcPortOperTopology == multipoint " + ::= { sdlcPortOperEntry 10 } + +sdlcPortOperLastModifyTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the value of sysUpTime + + + +Hilgeman, Nix, Bartky & Clark [Page 18] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + when this port definition was last modified. + If the port has not been modified, then this + value shall be zero." + ::= { sdlcPortOperEntry 11 } + +sdlcPortOperLastFailTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the value of sysUpTime + when this SDLC port last failed. If the port + has not failed, then this value shall be zero." + ::= { sdlcPortOperEntry 12 } + +sdlcPortOperLastFailCause OBJECT-TYPE + SYNTAX INTEGER + { + undefined(1), + physical(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This enumerated object describes the cause of + the last failure of this SDLC port. If the + port has not failed, then this object has a + value of undefined(1)." + DEFVAL { undefined } + ::= { sdlcPortOperEntry 13 } + + + + + + + + + + + + + + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 19] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +-- ************************************************************* +-- * * +-- * THE SDLC PORT STATISTICS TABLE * +-- * * +-- ************************************************************* + +sdlcPortStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcPortStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Each entry in this table contains statistics + for a specific SDLC port." + ::= { sdlcPortGroup 3 } + +sdlcPortStatsEntry OBJECT-TYPE + SYNTAX SdlcPortStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of statistics for an SDLC port." + INDEX { ifIndex } + ::= { sdlcPortStatsTable 1 } + +SdlcPortStatsEntry ::= SEQUENCE +{ + sdlcPortStatsPhysicalFailures Counter32, + sdlcPortStatsInvalidAddresses Counter32, + sdlcPortStatsDwarfFrames Counter32, + sdlcPortStatsPollsIn Counter32, + sdlcPortStatsPollsOut Counter32, + sdlcPortStatsPollRspsIn Counter32, + sdlcPortStatsPollRspsOut Counter32, + sdlcPortStatsLocalBusies Counter32, + sdlcPortStatsRemoteBusies Counter32, + sdlcPortStatsIFramesIn Counter32, + sdlcPortStatsIFramesOut Counter32, + sdlcPortStatsOctetsIn Counter32, + sdlcPortStatsOctetsOut Counter32, + sdlcPortStatsProtocolErrs Counter32, + sdlcPortStatsActivityTOs Counter32, + sdlcPortStatsRNRLIMITs Counter32, + sdlcPortStatsRetriesExps Counter32, + sdlcPortStatsRetransmitsIn Counter32, + sdlcPortStatsRetransmitsOut Counter32 +} + +sdlcPortStatsPhysicalFailures OBJECT-TYPE + + + +Hilgeman, Nix, Bartky & Clark [Page 20] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of times + this port has failed due to its physical media + since port startup. At port startup time, + this object must be initialized to zero." + ::= { sdlcPortStatsEntry 1 } + +sdlcPortStatsInvalidAddresses OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + frames received by this port with invalid link + station addresses." + ::= { sdlcPortStatsEntry 2 } + +sdlcPortStatsDwarfFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + frames received by this port which were + delivered intact by the physical layer but were + too short to be legal. + + Ignoring the frame check sequence (FCS), a + frame is considered to be too short if it + is less than 2 bytes for sdlcLSOperMODULO of + eight, or if it is less than 3 bytes for + sdlcLSOperMODULO of onetwentyeight." + + ::= { sdlcPortStatsEntry 3 } + +sdlcPortStatsPollsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of polls + received by this port since the port was + created." + + ::= { sdlcPortStatsEntry 4 } + + + +Hilgeman, Nix, Bartky & Clark [Page 21] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcPortStatsPollsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of polls + sent by this port since the port was created." + + ::= { sdlcPortStatsEntry 5 } + +sdlcPortStatsPollRspsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of poll + responses received by this port since the port + was created." + + ::= { sdlcPortStatsEntry 6 } + +sdlcPortStatsPollRspsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of poll + responses sent by this port since the port was + created." + + ::= { sdlcPortStatsEntry 7 } + +sdlcPortStatsLocalBusies OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + times that the local SDLC link stations on + this port have entered a busy state (RNR). + This object is initialized to zero when the + port is created." + ::= { sdlcPortStatsEntry 8 } + +sdlcPortStatsRemoteBusies OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + + + +Hilgeman, Nix, Bartky & Clark [Page 22] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + DESCRIPTION + "This object reflects the total number of + times that the adjacent (i.e., remote) SDLC + link stations on this port have entered a busy + state (RNR). This object is initialized to + zero when the port is created." + ::= { sdlcPortStatsEntry 9 } + +sdlcPortStatsIFramesIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + I-Frames that have been received by SDLC link + stations on this port. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 10 } + +sdlcPortStatsIFramesOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + I-Frames that have been transmitted by SDLC + link stations on this port. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 11 } + +sdlcPortStatsOctetsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total octets + received from adjacent SDLC link stations on + this port. This object covers the address, + control, and information field of I-Frames + only. This object is initialized to zero when + the port is created." + ::= { sdlcPortStatsEntry 12 } + +sdlcPortStatsOctetsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 23] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "This object reflects the total octets + transmitted to adjacent SDLC link stations on + this port. This object covers the address, + control, and information field of I-Frames + only. This object is initialized to zero when + the port is created." + ::= { sdlcPortStatsEntry 13 } + +sdlcPortStatsProtocolErrs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + times that the SDLC link stations on this port + have deactivated the link as a result of + having received a protocol violation from the + adjacent link station. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 14 } + +sdlcPortStatsActivityTOs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + times that the SDLC link stations on this port + have deactivated the link as a result of no + activity on the link. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 15 } + +sdlcPortStatsRNRLIMITs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + times that the SDLC link stations on this port + have deactivated the link as a result of its + RNRLIMIT timer expiring. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 16 } + +sdlcPortStatsRetriesExps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + + + +Hilgeman, Nix, Bartky & Clark [Page 24] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + STATUS current + DESCRIPTION + "This object reflects the total number of + times that the SDLC link stations on this port + have deactivated the link as a result of a + retry sequence being exhausted. This object + is initialized to zero when the port is + created." + ::= { sdlcPortStatsEntry 17 } + +sdlcPortStatsRetransmitsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + I-Frames retransmitted by remote link stations + for all SDLC link stations on this port. This + object is initialized to zero when the port is + created." + ::= { sdlcPortStatsEntry 18 } + +sdlcPortStatsRetransmitsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + I-Frames retransmitted by all local SDLC link + stations on this port. This object is + initialized to zero when the port is created." + ::= { sdlcPortStatsEntry 19 } + + + + + + + + + + + + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 25] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +-- +-- THE SDLC LINK STATION GROUP +-- =========================== +-- + +-- The following classes of information is modelled for each SDLC link +-- station: +-- +-- 1. ADMINISTRATIVE ( read-write) +-- 2. OPERATIONAL ( read-only) +-- 3. STATISTICS ( read-only) + +-- ************************************************************* +-- * * +-- * THE SDLC LINK STATION ADMINISTRATIVE TABLE * +-- * * +-- ************************************************************* + +sdlcLSAdminTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcLSAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains objects that can be + changed to manage an SDLC link station. + Changing one of these parameters may take + effect in the operating link immediately or may + wait until the link is restarted depending on + the details of the implementation. + + The entries in sdlcLSAdminTable can be created + either by an agent or a management station. The + management station can create an entry in + sdlcLSAdminTable by setting the appropriate + value in sdlcLSAdminRowStatus. + + Most of the objects in this read-create table + have corresponding read-only objects in the + sdlcLSOperTable that reflect the current + operating value. + + The operating values may be different from + these configured values if changed by XID + negotiation or if a configured parameter was + changed after the link was started." + ::= { sdlcLSGroup 1 } + +sdlcLSAdminEntry OBJECT-TYPE + + + +Hilgeman, Nix, Bartky & Clark [Page 26] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + SYNTAX SdlcLSAdminEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configured values for an SDLC link + station." + INDEX { ifIndex, sdlcLSAddress } + ::= { sdlcLSAdminTable 1 } + +SdlcLSAdminEntry ::= SEQUENCE +{ + sdlcLSAddress INTEGER, + sdlcLSAdminName DisplayString, + sdlcLSAdminState INTEGER, + sdlcLSAdminISTATUS INTEGER, + sdlcLSAdminMAXDATASend Integer32, + sdlcLSAdminMAXDATARcv Integer32, + sdlcLSAdminREPLYTO TimeInterval, + sdlcLSAdminMAXIN INTEGER, + sdlcLSAdminMAXOUT INTEGER, + sdlcLSAdminMODULO INTEGER, + sdlcLSAdminRETRIESm INTEGER, + sdlcLSAdminRETRIESt TimeInterval, + sdlcLSAdminRETRIESn Integer32, + sdlcLSAdminRNRLIMIT TimeInterval, + sdlcLSAdminDATMODE INTEGER, + sdlcLSAdminGPoll INTEGER, + sdlcLSAdminSimRim INTEGER, + sdlcLSAdminXmitRcvCap INTEGER, + sdlcLSAdminRowStatus RowStatus +} + +sdlcLSAddress OBJECT-TYPE + SYNTAX INTEGER (1..255) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This value is the poll address of the + secondary link station for this SDLC link. It + uniquely identifies the SDLC link station + within a single SDLC port." + ::= { sdlcLSAdminEntry 1 } + +sdlcLSAdminName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..10)) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 27] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "An octet string that defines the local name of + the SDLC link station. This field may be sent + in the XID3 control vector 0x0E, type 0xF7." + ::= { sdlcLSAdminEntry 2 } + +sdlcLSAdminState OBJECT-TYPE + SYNTAX INTEGER + { + inactive(1), + active(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the desired state of the + SDLC station. The managed system shall attempt + to keep the operational state, sdlcLSOperState, + consistent with this value." + DEFVAL { active } + ::= { sdlcLSAdminEntry 3 } + +sdlcLSAdminISTATUS OBJECT-TYPE + SYNTAX INTEGER + { + inactive(1), + active(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This parameter controls the desired state, + sdlcLSAdminState, of the SDLC link station at + link station start-up." + DEFVAL { active } + ::= { sdlcLSAdminEntry 4 } + +sdlcLSAdminMAXDATASend OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object contains the maximum PDU size that + the local link station thinks it can send to + the adjacent link station before having + received any XID from the ALS. After the + maximum PDU size that the ALS can receive is + known (via XID exchange) that value is + reflected in sdlcLSOperMAXDATASend and takes + + + +Hilgeman, Nix, Bartky & Clark [Page 28] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + precedence over this object. + + This value includes the Transmission Header + (TH) and the Request Header (RH)." + ::= { sdlcLSAdminEntry 5 } + +sdlcLSAdminMAXDATARcv OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object contains the maximum PDU size that + the local link station can receive from the + adjacent link station. This value is sent in + the XID to the ALS. + + This value includes the Transmission Header + (TH) and the Request Header (RH)." + ::= { sdlcLSAdminEntry 6 } + +sdlcLSAdminREPLYTO OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the reply timeout (in + 1/100ths of a second) for an SDLC link + station. If the link station does not receive + a response to a poll or message before the + specified time expires then the appropriate + error recovery shall be initiated. + + The object descriptor contains the name of an + NCP configuration parameter, REPLYTO. Please + note that the value of this object represents + 1/100ths of a second while the NCP REPLYTO is + represented in 1/10ths of a second. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, sdlcLSOperREPLYTO, + until the link station is cycled inactive. + + This object only has meaning for SDLC ports + where sdlcPortAdminRole == primary " + DEFVAL { 100 } + ::= { sdlcLSAdminEntry 7 } + + + + +Hilgeman, Nix, Bartky & Clark [Page 29] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSAdminMAXIN OBJECT-TYPE + SYNTAX INTEGER (1..127) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the maximum number of + unacknowledged I-frames which an SDLC link + station may receive. This should range from 1 + to (sdlcLSAdminMODULO - 1). This value is sent + in the XID to the ALS. + + A write operation to this administered value + will not change the operational value, + sdlcLSOperMAXIN, until the link station is + cycled inactive." + DEFVAL { 7 } + ::= { sdlcLSAdminEntry 8 } + +sdlcLSAdminMAXOUT OBJECT-TYPE + SYNTAX INTEGER (1..127) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the maximum number of + consecutive unacknowledged I-frames which an + SDLC link station shall send without an + acknowledgement. This shall range from 1 to + (sdlcLSAdminMODULO - 1). + + For link stations on switched SDLC lines, + certain implementions may choose to override + this administered value with the value + received in the XID exchange. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, + sdlcLSOperMAXOUT, until the link station is + cycled inactive. + + An implementation can support only modulo 8, + only modulo 128, or both." + DEFVAL { 1 } + ::= { sdlcLSAdminEntry 9 } + +sdlcLSAdminMODULO OBJECT-TYPE + SYNTAX INTEGER + { + + + +Hilgeman, Nix, Bartky & Clark [Page 30] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + eight(8), + onetwentyeight(128) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the modulus for an SDLC + link station. This modulus determines the size + of the rotating acknowledgement window used the + SDLC link station pair. + + A write operation to this administered value + will not change the operational value, + sdlcLSOperMODULO, until the link station is + cycled inactive. + + An implementation can support only modulo 8, + only modulo 128, or both." + DEFVAL { eight } + ::= { sdlcLSAdminEntry 10 } + +sdlcLSAdminRETRIESm OBJECT-TYPE + SYNTAX INTEGER (0..128) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls number of retries in a + retry sequence for the local SDLC link + station. A retry sequence is a series of + retransmitted frames ( data or control) for + which no positive acknowledgement is received. + + The number of times that the retry sequence is + to be repeated is controlled by the object: + sdlcLSAdminRETRIESn. The interval between retry + sequences is controlled by the object: + sdlcLSAdminRETRIESt. + + A value of zero indicates no retries. If the + value of sdlcLSAdminRETRIESm is zero, then the + values of sdlcLSAdminRETRIESt and + sdlcLSAdminRETRIESn should also be zero. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, + sdlcLSOperRETRIESm, until the link station is + cycled inactive." + + + +Hilgeman, Nix, Bartky & Clark [Page 31] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + DEFVAL { 15 } + ::= { sdlcLSAdminEntry 11 } + +sdlcLSAdminRETRIESt OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the interval (in 1/100ths + of a second) between retry sequences for the + local SDLC link station if multiple retry + sequences are specified . A retry sequence is + a series of retransmitted frames ( data or + control) for which no positive acknowledgement + is received. + + The number of repeated retries sequences is + controlled by the object: sdlcLSAdminRETRIESn. + The retries per sequence is controlled by the + object: sdlcLSAdminRETRIESm. + + The object descriptor contains the name of an + NCP configuration parameter, RETRIESt. Please + note that the value of this object represents + 1/100ths of a second while the NCP RETRIESt is + represented in seconds. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, + sdlcLSOperRETRIESt, until the link station is + cycled inactive." + DEFVAL { 0 } + ::= { sdlcLSAdminEntry 12 } + +sdlcLSAdminRETRIESn OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the number of times that + a retry sequence is repeated for the local SDLC + link station. A retry sequence is a series of + retransmitted frames ( data or control) for + which no positive acknowledgement is received. + + The interval between retry sequences is + controlled by the object: sdlcLSAdminRETRIESn. + + + +Hilgeman, Nix, Bartky & Clark [Page 32] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + The retries per sequence is controlled by the + object: sdlcLSAdminRETRIESm. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, + sdlcLSOperRETRIESn, until the link station is + cycled inactive." + DEFVAL { 0 } + ::= { sdlcLSAdminEntry 13 } + +sdlcLSAdminRNRLIMIT OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the length of time (in + 1/100ths of a second) that an SDLC link station + will allow its adjacent link station to remain + in a busy (RNR) state before declaring it + inoperative. + + A value of sdlcLSAdminRNRLIMIT == 0 means there + is no limit. + + The object descriptor contains the name of an + NCP configuration parameter, RNRLIMIT. Please + note that the value of this object represents + 1/100ths of a second while the NCP RNRLIMIT is + represented in minutes. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, + sdlcLSOperRNRLIMIT, until the link station is + cycled inactive." + DEFVAL { 18000 } + ::= { sdlcLSAdminEntry 14 } + +sdlcLSAdminDATMODE OBJECT-TYPE + SYNTAX INTEGER + { + half(1), + full(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 33] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "This object controls whether communications + mode with the adjacent link station is + two-way-alternate (half) or two-way-simultaneous + (full). + + A write operation to this administered value + will not change the operational value, + sdlcLSOperDATMODE, until the link station is + cycled inactive." + DEFVAL { half } + ::= { sdlcLSAdminEntry 15 } + +sdlcLSAdminGPoll OBJECT-TYPE + SYNTAX INTEGER (0..254) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object describes the group poll address + for this link station instance. If group poll + is not in effect for this link station + instance, the value for sdlcLSAdminGPoll should + be zero. + + Depending on the implementation, a write + operation to this administered value may not + change the operational value, sdlcLSOperGPoll, + until the link station is cycled inactive." + ::= { sdlcLSAdminEntry 16 } + +sdlcLSAdminSimRim OBJECT-TYPE + SYNTAX INTEGER + { + no(1), + yes(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the support for + transmission and receipt of SIM and RIM control + frames for this link station. The value of + this object controls the setting of the + transmit-receive capability sent in the XID + field." + DEFVAL { no } + ::= { sdlcLSAdminEntry 17 } + +sdlcLSAdminXmitRcvCap OBJECT-TYPE + + + +Hilgeman, Nix, Bartky & Clark [Page 34] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + SYNTAX INTEGER + { + twa(1), + tws(2) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object controls the transmit-receive + capabilities for this SDLC link station. The + value of this object establishes the value of + the transmit-receive capability indicator sent + in the XID image to the adjacent link station." + DEFVAL { twa } + ::= { sdlcLSAdminEntry 18 } + +sdlcLSAdminRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used by a management station to + create or delete the row entry in + sdlcLSAdminTable following the RowStatus + textual convention. + + Upon successful creation of the row, an agent + automatically creates a corresponding entry in + the sdlcLSOperTable with sdlcLSOperState equal + to 'discontacted (1)'." + ::= { sdlcLSAdminEntry 19 } + +-- ************************************************************* +-- * * +-- * THE SDLC LINK STATION OPERATIONAL TABLE * +-- * * +-- ************************************************************* + +sdlcLSOperTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcLSOperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains current SDLC link + parameters. Many of these objects have + corresponding objects in the + sdlcLSAdminTable." + ::= { sdlcLSGroup 2 } + + + +Hilgeman, Nix, Bartky & Clark [Page 35] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSOperEntry OBJECT-TYPE + SYNTAX SdlcLSOperEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of status and control values for an + SDLC link station." + INDEX { ifIndex, sdlcLSAddress } + ::= { sdlcLSOperTable 1 } + +SdlcLSOperEntry ::= SEQUENCE +{ + sdlcLSOperName DisplayString, + sdlcLSOperRole INTEGER, + sdlcLSOperState INTEGER, + sdlcLSOperMAXDATASend Integer32, + sdlcLSOperREPLYTO TimeInterval, + sdlcLSOperMAXIN INTEGER, + sdlcLSOperMAXOUT INTEGER, + sdlcLSOperMODULO INTEGER, + sdlcLSOperRETRIESm INTEGER, + sdlcLSOperRETRIESt TimeInterval, + sdlcLSOperRETRIESn INTEGER, + sdlcLSOperRNRLIMIT TimeInterval, + sdlcLSOperDATMODE INTEGER, + sdlcLSOperLastModifyTime TimeTicks, + sdlcLSOperLastFailTime TimeTicks, + sdlcLSOperLastFailCause INTEGER, + sdlcLSOperLastFailCtrlIn OCTET STRING, + sdlcLSOperLastFailCtrlOut OCTET STRING, + sdlcLSOperLastFailFRMRInfo OCTET STRING, + sdlcLSOperLastFailREPLYTOs Counter32, + sdlcLSOperEcho INTEGER, + sdlcLSOperGPoll INTEGER, + sdlcLSOperSimRim INTEGER, + sdlcLSOperXmitRcvCap INTEGER +} + +sdlcLSOperName OBJECT-TYPE + SYNTAX DisplayString (SIZE (1..10)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An octet string that defines the name of the + remote SDLC link station. This field is + received in the XID3 control vector 0x0E, type + 0xF7." + ::= { sdlcLSOperEntry 1 } + + + +Hilgeman, Nix, Bartky & Clark [Page 36] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSOperRole OBJECT-TYPE + SYNTAX INTEGER + { + primary(1), + secondary(2), + undefined(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current role that the + link station is assuming. + + The value of sdlcLSOperRole is undefined(3) + whenever the link station role has not yet been + established by the mode setting command." + ::= { sdlcLSOperEntry 2 } + +sdlcLSOperState OBJECT-TYPE + SYNTAX INTEGER + { + discontacted(1), + contactPending(2), + contacted(3), + discontactPending(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the operational state of + the SDLC link station. The managed system + shall attempt to keep this value consistent + with the administered state, sdlcLSAdminState" + ::= { sdlcLSOperEntry 3 } + +sdlcLSOperMAXDATASend OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the actual maximum PDU + size that the local link station can send to + the adjacent link station. This object is + established from the value received in the XID + from the adjacent link station. If no XID + is received, then this value is implementation + dependent (for instance, it could be the value + of sdlcLSAdminMAXDATASend). + + + +Hilgeman, Nix, Bartky & Clark [Page 37] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + This value includes the Transmission Header + (TH) and the Request Header (RH)." + ::= { sdlcLSOperEntry 4 } + +sdlcLSOperREPLYTO OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current reply timeout + (in 1/100ths of a second) for an SDLC link + station. If the link station does not receive + a response to a poll or message before the + specified time expires then the appropriate + error recovery shall be initiated. + + The object descriptor contains the name of an + NCP configuration parameter, REPLYTO. Please + note that the value of this object represents + 1/100ths of a second while the NCP REPLYTO is + represented in 1/10ths of a second. + + This object only has meaning for SDLC ports + where sdlcPortOperRole == primary " + ::= { sdlcLSOperEntry 5 } + +sdlcLSOperMAXIN OBJECT-TYPE + SYNTAX INTEGER (1..127) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current maximum + number of unacknowledged I-frames which an SDLC + link station may receive. This shall range + from 1 to (sdlcLSOperMODULO - 1)." + ::= { sdlcLSOperEntry 6 } + +sdlcLSOperMAXOUT OBJECT-TYPE + SYNTAX INTEGER (1..127) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object controls the maximum number of + consecutive unacknowledged I-frames which an + SDLC link station shall send without an + acknowledgement. This shall range from 1 to + (sdlcLSAdminMODULO - 1). + + + + +Hilgeman, Nix, Bartky & Clark [Page 38] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + This value may controlled by the administered + MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value + received during the XID exchange." + ::= { sdlcLSOperEntry 7 } + +sdlcLSOperMODULO OBJECT-TYPE + SYNTAX INTEGER + { + eight(8), + onetwentyeight(128) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current modulus for + an SDLC link station. This modulus determines + the size of rotating acknowledgement window + used by the SDLC link station pair." + DEFVAL { eight } + ::= { sdlcLSOperEntry 8 } + +sdlcLSOperRETRIESm OBJECT-TYPE + SYNTAX INTEGER (0..128) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object controls number of retries in a + retry sequence for an SDLC link station. A + retry sequence is a series of retransmitted + frames ( data or control) for which no positive + acknowledgement is received. + + The current number of times that the retry + sequence is to be repeated is reflected by the + object: sdlcLSOperRETRIESn. The current + interval between retry sequences is reflected + by the object: sdlcLSOperRETRIESt." + ::= { sdlcLSOperEntry 9 } + +sdlcLSOperRETRIESt OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current interval (in + 1/100ths of a second) between retry sequences + for an SDLC link station if multiple retry + sequences are specified. A retry sequence is a + + + +Hilgeman, Nix, Bartky & Clark [Page 39] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + series of retransmitted frames ( data or + control) for which no positive acknowledgement + is received. + + The object descriptor contains the name of an + NCP configuration parameter, RETRIESt. Please + note that the value of this object represents + 1/100ths of a second while the NCP RETRIESt is + represented in seconds. + + The current number of repeated retries + sequences is reflected by the object: + sdlcLSOperRETRIESn. The current retries per + sequence is reflected by the object: + sdlcLSOperRETRIESm." + ::= { sdlcLSOperEntry 10 } + +sdlcLSOperRETRIESn OBJECT-TYPE + SYNTAX INTEGER (0..127) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current number of + times that a retry sequence is repeated for an + SDLC link station. A retry sequence is a + series of retransmitted frames ( data or + control) for which no positive acknowledgement + is received. + + The current interval between retry sequences is + reflected by the object: sdlcLSOperRETRIESn. + The current retries per sequence is reflected + by the object: sdlcLSOperRETRIESm." + ::= { sdlcLSOperEntry 11 } + +sdlcLSOperRNRLIMIT OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the current length of + time (in 1/100ths of a second) that an SDLC + link station will allow its adjacent link + station to remain in a busy (RNR) state before + declaring it inoperative. + + The object descriptor contains the name of an + NCP configuration parameter, RNRLIMIT. Please + + + +Hilgeman, Nix, Bartky & Clark [Page 40] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + note that the value of this object represents + 1/100ths of a second while the NCP RNRLIMIT is + represented in minutes. + + A value of sdlcLSOperRNRLIMIT == 0 means there + is no limit." + ::= { sdlcLSOperEntry 12 } + +sdlcLSOperDATMODE OBJECT-TYPE + SYNTAX INTEGER + { + half(1), + full(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects whether the current + communications mode with the adjacent link + station is two-way-alternate (half) or + two-way-simultaneous (full)." + ::= { sdlcLSOperEntry 13 } + +sdlcLSOperLastModifyTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the value of sysUpTime + when this link station definition was last + modified. If the link station has not been + modified, then this value shall be zero." + ::= { sdlcLSOperEntry 14 } + +sdlcLSOperLastFailTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the value of sysUpTime + when this SDLC link station last failed. If + the link station has not failed, then this + value shall be zero." + ::= { sdlcLSOperEntry 15 } + +sdlcLSOperLastFailCause OBJECT-TYPE + SYNTAX INTEGER + { + + + +Hilgeman, Nix, Bartky & Clark [Page 41] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + undefined(1), + rxFRMR(2), + txFRMR(3), + noResponse(4), + protocolErr(5), + noActivity(6), + rnrLimit(7), + retriesExpired(8) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This enumerated object reflects the cause of + the last failure of this SDLC link station. If + the link station has not failed, then this + object will have a value of undefined(1)." + DEFVAL { undefined } + ::= { sdlcLSOperEntry 16 } + +sdlcLSOperLastFailCtrlIn OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..2)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the last control octet or + octets (depending on modulus) received by this + SDLC link station at the time of the last + failure. If the link station has not failed, + then this value has no meaning." + ::= { sdlcLSOperEntry 17 } + +sdlcLSOperLastFailCtrlOut OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(1..2)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the last control octet or + octets (depending on modulus) sent by this SDLC + link station at the time of the last failure. + If the link station has not failed, then this + value has no meaning." + ::= { sdlcLSOperEntry 18 } + +sdlcLSOperLastFailFRMRInfo OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(3)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 42] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "This object reflects the information field of + the FRMR frame if the last failure for this + SDLC link station was as a result of an invalid + frame. Otherwise, this field has no meaning." + ::= { sdlcLSOperEntry 19 } + +sdlcLSOperLastFailREPLYTOs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the number of times that + the REPLYTO timer had expired for an SDLC link + station at the time of the last failure. If the + link station has not failed, then this value + has no meaning." + ::= { sdlcLSOperEntry 20 } + +sdlcLSOperEcho OBJECT-TYPE + SYNTAX INTEGER + { + no(1), + yes(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies whether the echo bit is + in effect for this particular link station." + DEFVAL { no } + ::= { sdlcLSOperEntry 21 } + +sdlcLSOperGPoll OBJECT-TYPE + SYNTAX INTEGER (0..254) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object describes the group poll address + in effect for this link station instance." + DEFVAL { 0 } + ::= { sdlcLSOperEntry 22 } + +sdlcLSOperSimRim OBJECT-TYPE + SYNTAX INTEGER + { + no(1), + yes(2) + } + + + +Hilgeman, Nix, Bartky & Clark [Page 43] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the support for + transmission and receipt of SIM and RIM control + frames for the adjacent link station. The + value of this object is set from the XID field + received from the adjacent link station." + DEFVAL { no } + ::= { sdlcLSOperEntry 23 } + +sdlcLSOperXmitRcvCap OBJECT-TYPE + SYNTAX INTEGER + { + twa(1), + tws(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the transmit-receive + capabilities for the adjacent SDLC link + station. The value of this object is the value + of the transmit-receive capability indicator + received in the XID image from the adjacent + link station." + DEFVAL { twa } + ::= { sdlcLSOperEntry 24 } + + +-- ************************************************************* +-- * * +-- * THE SDLC LINK STATION STATISTICS TABLE * +-- * * +-- ************************************************************* + +sdlcLSStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF SdlcLSStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Each entry in this table contains statistics + for a specific SDLC link station." + ::= { sdlcLSGroup 3 } + +sdlcLSStatsEntry OBJECT-TYPE + SYNTAX SdlcLSStatsEntry + MAX-ACCESS not-accessible + + + +Hilgeman, Nix, Bartky & Clark [Page 44] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + STATUS current + DESCRIPTION + "A list of statistics for an SDLC link station." + INDEX { ifIndex, sdlcLSAddress } + ::= { sdlcLSStatsTable 1 } + +SdlcLSStatsEntry ::= SEQUENCE +{ + sdlcLSStatsBLUsIn Counter32, + sdlcLSStatsBLUsOut Counter32, + sdlcLSStatsOctetsIn Counter32, + sdlcLSStatsOctetsOut Counter32, + sdlcLSStatsPollsIn Counter32, + sdlcLSStatsPollsOut Counter32, + sdlcLSStatsPollRspsIn Counter32, + sdlcLSStatsPollRspsOut Counter32, + sdlcLSStatsLocalBusies Counter32, + sdlcLSStatsRemoteBusies Counter32, + sdlcLSStatsIFramesIn Counter32, + sdlcLSStatsIFramesOut Counter32, + sdlcLSStatsUIFramesIn Counter32, + sdlcLSStatsUIFramesOut Counter32, + sdlcLSStatsXIDsIn Counter32, + sdlcLSStatsXIDsOut Counter32, + sdlcLSStatsTESTsIn Counter32, + sdlcLSStatsTESTsOut Counter32, + sdlcLSStatsREJsIn Counter32, + sdlcLSStatsREJsOut Counter32, + sdlcLSStatsFRMRsIn Counter32, + sdlcLSStatsFRMRsOut Counter32, + sdlcLSStatsSIMsIn Counter32, + sdlcLSStatsSIMsOut Counter32, + sdlcLSStatsRIMsIn Counter32, + sdlcLSStatsRIMsOut Counter32, + sdlcLSStatsDISCIn Counter32, + sdlcLSStatsDISCOut Counter32, + sdlcLSStatsUAIn Counter32, + sdlcLSStatsUAOut Counter32, + sdlcLSStatsDMIn Counter32, + sdlcLSStatsDMOut Counter32, + sdlcLSStatsSNRMIn Counter32, + sdlcLSStatsSNRMOut Counter32, + sdlcLSStatsProtocolErrs Counter32, + sdlcLSStatsActivityTOs Counter32, + sdlcLSStatsRNRLIMITs Counter32, + sdlcLSStatsRetriesExps Counter32, + sdlcLSStatsRetransmitsIn Counter32, + sdlcLSStatsRetransmitsOut Counter32 + + + +Hilgeman, Nix, Bartky & Clark [Page 45] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +} + +sdlcLSStatsBLUsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total basic link + units (BLUs; frames) received from an adjacent + SDLC link station since link station startup. + At link station startup time, this object must + be initialized to zero." + ::= { sdlcLSStatsEntry 1 } + +sdlcLSStatsBLUsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total basic link + units (BLUs; frames), transmitted to an + adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 2 } + +sdlcLSStatsOctetsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total octets received + from an adjacent SDLC link station since link + station startup. This object covers the + address, control, and information field of + I-Frames only. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 3 } + +sdlcLSStatsOctetsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total octets + transmitted to an adjacent SDLC link station + since link station startup. This object covers + the address, control, and information field of + + + +Hilgeman, Nix, Bartky & Clark [Page 46] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + I-Frames only. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 4 } + +sdlcLSStatsPollsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total polls received + from an adjacent SDLC link station since link + station startup. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 5 } + +sdlcLSStatsPollsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total polls sent to + an adjacent SDLC link station since link + station startup. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 6 } + +sdlcLSStatsPollRspsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of poll + responses sent to the adjacent SDLC link + station since link station startup. This value + includes I-frames that are sent in response to + a poll. + + At link station startup time, this object must + be initialized to zero." + ::= { sdlcLSStatsEntry 7 } + +sdlcLSStatsPollRspsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of poll + responses received from the adjacent SDLC link + + + +Hilgeman, Nix, Bartky & Clark [Page 47] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + station since station startup. This value + includes I-frames that are received in response + to a poll. + + At link station startup time, this object must + be initialized to zero." + ::= { sdlcLSStatsEntry 8 } + +sdlcLSStatsLocalBusies OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of times + that the local SDLC link station has entered a + busy state (RNR) since link station startup. + At link station startup time, this object must + be initialized to zero." + ::= { sdlcLSStatsEntry 9 } + +sdlcLSStatsRemoteBusies OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of times + that an adjacent ( remote) SDLC link station + has entered a busy state (RNR) since link + station startup. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 10 } + +sdlcLSStatsIFramesIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total I-frames + received from an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 11 } + +sdlcLSStatsIFramesOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + + + +Hilgeman, Nix, Bartky & Clark [Page 48] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + DESCRIPTION + "This object reflects the total I-frames + transmitted to an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 12 } + +sdlcLSStatsUIFramesIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total UI-frames + received from an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 13 } + +sdlcLSStatsUIFramesOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total UI-frames + transmitted to an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 14 } + +sdlcLSStatsXIDsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total XID frames + received from an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 15 } + +sdlcLSStatsXIDsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total XID frames + transmitted to an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 16 } + + + + +Hilgeman, Nix, Bartky & Clark [Page 49] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSStatsTESTsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total TEST frames, + commands or responses, received from an + adjacent SDLC link station since link station + startup." + ::= { sdlcLSStatsEntry 17 } + +sdlcLSStatsTESTsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total TEST frames, + commands or responses, transmitted to an + adjacent SDLC link station since link station + startup." + ::= { sdlcLSStatsEntry 18 } + +sdlcLSStatsREJsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total REJ frames + received from an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 19 } + +sdlcLSStatsREJsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total REJ frames + transmitted to an adjacent SDLC link station + since link station startup." + ::= { sdlcLSStatsEntry 20 } + +sdlcLSStatsFRMRsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total frame reject + + + +Hilgeman, Nix, Bartky & Clark [Page 50] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + (FRMR) frames received from an adjacent SDLC + link station since link station startup." + ::= { sdlcLSStatsEntry 21 } + +sdlcLSStatsFRMRsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total frame reject + (FRMR) frames transmitted to an adjacent SDLC + link station since link station startup." + ::= { sdlcLSStatsEntry 22 } + +sdlcLSStatsSIMsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total set + initialization mode (SIM) frames received from + an adjacent SDLC link station since link station + startup." + ::= { sdlcLSStatsEntry 23 } + +sdlcLSStatsSIMsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total set + initialization mode (SIM) frames transmitted to + an adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 24 } + +sdlcLSStatsRIMsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total request + initialization mode (RIM) frames received from + an adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 25 } + + + +Hilgeman, Nix, Bartky & Clark [Page 51] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSStatsRIMsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total request + initialization mode (RIM) frames transmitted to + an adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 26 } + +sdlcLSStatsDISCIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + disconnect (DISC) requests received from an + adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 27 } + +sdlcLSStatsDISCOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + disconnect (DISC) requests transmited to an + adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 28 } + +sdlcLSStatsUAIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + unnumbered acknowledgements (UA) requests + received from an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 29 } + + + +Hilgeman, Nix, Bartky & Clark [Page 52] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +sdlcLSStatsUAOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + unnumbered acknowledgements (UA) requests + transmited to an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 30 } + +sdlcLSStatsDMIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + disconnect mode (DM) requests received from an + adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 31 } + +sdlcLSStatsDMOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + disconnect mode (DM) requests transmited to an + adjacent SDLC link station since link station + startup. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 32 } + +sdlcLSStatsSNRMIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + set normal response mode (SNRM/SNRME) requests + received from an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + + + +Hilgeman, Nix, Bartky & Clark [Page 53] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + ::= { sdlcLSStatsEntry 33 } + +sdlcLSStatsSNRMOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + set normal response mode (SNRM/SNRME) requests + transmited to an adjacent SDLC link station + since link station startup. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 34 } + +sdlcLSStatsProtocolErrs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total occurrences, + since link station startup, where this SDLC + link station has inactivated the link as a + result of receiving a frame from its adjacent + link station which was in violation of the + protocol. At link station startup time, this + object must be initialized to zero." + ::= { sdlcLSStatsEntry 35 } + +sdlcLSStatsActivityTOs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total occurrences, + since startup, where this SDLC link station has + inactivated the link as a result of no activity + on the link. At link station startup time, + this object must be initialized to zero." + ::= { sdlcLSStatsEntry 36 } + +sdlcLSStatsRNRLIMITs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total occurrences, + since startup, where this SDLC link station has + + + +Hilgeman, Nix, Bartky & Clark [Page 54] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + inactivated the link as a result of its + RNRLIMIT timer expiring. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 37 } + +sdlcLSStatsRetriesExps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total occurrences, + since startup, where this SDLC link station has + inactivated the link as a result of a retry + sequence being exhausted. At link station + startup time, this object must be initialized + to zero." + ::= { sdlcLSStatsEntry 38 } + +sdlcLSStatsRetransmitsIn OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object reflects the total number of + information frames retransmitted by the remote + link station because the N(s) received from + that link station indicated that one or more + information frames sent by that station were + lost. This event causes the first missing + information frame of a window and all + subsequent information frames to be + retransmitted. At link station startup time, + this object must be initialized to zero. + + Management: If the value of + sdlcLSStatsRetransmitsIn grows over time, then + the quality of the serial line is in + question. You might want to look at + decreasing the value for + sdlcLSAdminMAXDATASend to compensate for the + lower quality line." + ::= { sdlcLSStatsEntry 39 } + +sdlcLSStatsRetransmitsOut OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + + + +Hilgeman, Nix, Bartky & Clark [Page 55] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + DESCRIPTION + "This object reflects the total number of + information frames retransmitted to a remote + link station because the N(r) received from + that link station indicated that one or more + information frames sent to that station were + lost. This event causes the first missing + information frame of a window and all + subsequent information frames to be + retransmitted. At link station startup time, + this object must be initialized to zero. + + Management: If the value of + sdlcLSStatsRetransmitsOut grows over time, + then the quality of the serial line is in + question. You might want to look at + decreasing the value for sdlcLSAdminMAXDATASend + to compensate for the lower quality line." + ::= { sdlcLSStatsEntry 40 } + +-- +-- TRAP DEFINITIONS +-- + +-- +-- Notifications +-- + +sdlcTraps OBJECT IDENTIFIER ::= { sdlc 3 } + +sdlcPortStatusChange NOTIFICATION-TYPE + OBJECTS { ifIndex, + ifAdminStatus, + ifOperStatus, + sdlcPortOperLastFailTime, + sdlcPortOperLastFailCause + } + STATUS current + DESCRIPTION + "This trap indicates that the state of an SDLC + port has transitioned to active or inactive." + ::= { sdlcTraps 1 } + +sdlcLSStatusChange NOTIFICATION-TYPE + OBJECTS { ifIndex, + sdlcLSAddress, + sdlcLSOperState, + sdlcLSAdminState, + + + +Hilgeman, Nix, Bartky & Clark [Page 56] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + sdlcLSOperLastFailTime, + sdlcLSOperLastFailCause, + sdlcLSOperLastFailFRMRInfo, + sdlcLSOperLastFailCtrlIn, + sdlcLSOperLastFailCtrlOut, + sdlcLSOperLastFailREPLYTOs + } + STATUS current + DESCRIPTION + "This trap indicates that the state of an SDLC + link station has transitioned to contacted or + discontacted." + ::= { sdlcTraps 2 } + + +-- +-- Conformance Information +-- + +sdlcConformance OBJECT IDENTIFIER ::= { sdlc 4 } + +sdlcCompliances OBJECT IDENTIFIER ::= { sdlcConformance 1 } +sdlcGroups OBJECT IDENTIFIER ::= { sdlcConformance 2 } + +-- +-- Compliance Statements +-- + +sdlcCoreCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The core compliance statement for all SDLC + nodes." + MODULE + MANDATORY-GROUPS + { + sdlcCorePortAdminGroup, + sdlcCorePortOperGroup, + sdlcCorePortStatsGroup, + sdlcCoreLSAdminGroup, + sdlcCoreLSOperGroup, + sdlcCoreLSStatsGroup + } + + OBJECT sdlcPortAdminName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + + +Hilgeman, Nix, Bartky & Clark [Page 57] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + OBJECT sdlcPortAdminRole + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcPortAdminType + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcPortAdminTopology + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcPortAdminISTATUS + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAddress + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminState + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminISTATUS + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminMAXDATASend + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminMAXDATARcv + MIN-ACCESS read-only + DESCRIPTION + + + +Hilgeman, Nix, Bartky & Clark [Page 58] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + "Write access is not required." + + OBJECT sdlcLSAdminMAXIN + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminMAXOUT + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminMODULO + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminRETRIESm + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminRETRIESt + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminRETRIESn + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminRNRLIMIT + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminDATMODE + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminGPoll + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminSimRim + + + +Hilgeman, Nix, Bartky & Clark [Page 59] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminRowStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + ::= { sdlcCompliances 1 } + +sdlcPrimaryCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for all nodes that + are performing the role of a Primary link + station." + MODULE + MANDATORY-GROUPS { sdlcPrimaryGroup } + + OBJECT sdlcPortAdminPAUSE + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcLSAdminREPLYTO + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + ::= { sdlcCompliances 2 } + +sdlcPrimaryMultipointCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for all nodes that + are performing the role of a primary link + station on a multipoint line." + MODULE + MANDATORY-GROUPS { sdlcPrimaryMultipointGroup } + + OBJECT sdlcPortAdminSERVLIM + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT sdlcPortAdminSlowPollTimer + MIN-ACCESS read-only + + + +Hilgeman, Nix, Bartky & Clark [Page 60] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + DESCRIPTION + "Write access is not required." + + ::= { sdlcCompliances 3 } + + +-- +-- Core Conformance Groups for All Link Stations +-- + +sdlcCoreGroups OBJECT IDENTIFIER ::= { sdlcGroups 1 } + +sdlcCorePortAdminGroup OBJECT-GROUP + OBJECTS + { + sdlcPortAdminName, sdlcPortAdminRole, + sdlcPortAdminType, sdlcPortAdminTopology, + sdlcPortAdminISTATUS + } + STATUS current + DESCRIPTION + "The sdlcCorePortAdminGroup defines objects + which are common to the PortAdmin group of all + compliant link stations." + ::= { sdlcCoreGroups 1 } + +sdlcCorePortOperGroup OBJECT-GROUP + OBJECTS + { + sdlcPortOperName, + sdlcPortOperRole, + sdlcPortOperType, + sdlcPortOperTopology, + sdlcPortOperISTATUS, + sdlcPortOperACTIVTO, + sdlcPortOperLastFailTime, + sdlcPortOperLastFailCause + } + STATUS current + DESCRIPTION + "The sdlcCorePortOperGroup defines objects + which are common to the PortOper group of all + compliant link stations." + ::= { sdlcCoreGroups 2 } + + +sdlcCorePortStatsGroup OBJECT-GROUP + OBJECTS + + + +Hilgeman, Nix, Bartky & Clark [Page 61] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + { + sdlcPortStatsPhysicalFailures, + sdlcPortStatsInvalidAddresses, + sdlcPortStatsDwarfFrames + } + STATUS current + DESCRIPTION + "The sdlcCorePortStatsGroup defines objects + which are common to the PortStats group of all + compliant link stations." + ::= { sdlcCoreGroups 3 } + + +sdlcCoreLSAdminGroup OBJECT-GROUP + OBJECTS + { + sdlcLSAddress, + sdlcLSAdminName, + sdlcLSAdminState, + sdlcLSAdminISTATUS, + sdlcLSAdminMAXDATASend, + sdlcLSAdminMAXDATARcv, + sdlcLSAdminMAXIN, + sdlcLSAdminMAXOUT, + sdlcLSAdminMODULO, + sdlcLSAdminRETRIESm, + sdlcLSAdminRETRIESt, + sdlcLSAdminRETRIESn, + sdlcLSAdminRNRLIMIT, + sdlcLSAdminDATMODE, + sdlcLSAdminGPoll, + sdlcLSAdminSimRim, + sdlcLSAdminRowStatus + } + STATUS current + DESCRIPTION + "The sdlcCorePortAdminGroup defines objects + which are common to the PortAdmin group of all + compliant link stations." + ::= { sdlcCoreGroups 4 } + +sdlcCoreLSOperGroup OBJECT-GROUP + OBJECTS + { + sdlcLSOperRole, + sdlcLSOperState, + sdlcLSOperMAXDATASend, + sdlcLSOperMAXIN, + + + +Hilgeman, Nix, Bartky & Clark [Page 62] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + sdlcLSOperMAXOUT, + sdlcLSOperMODULO, + sdlcLSOperRETRIESm, + sdlcLSOperRETRIESt, + sdlcLSOperRETRIESn, + sdlcLSOperRNRLIMIT, + sdlcLSOperDATMODE, + sdlcLSOperLastFailTime, + sdlcLSOperLastFailCause, + sdlcLSOperLastFailCtrlIn, + sdlcLSOperLastFailCtrlOut, + sdlcLSOperLastFailFRMRInfo, + sdlcLSOperLastFailREPLYTOs, + sdlcLSOperEcho, + sdlcLSOperGPoll + } + STATUS current + DESCRIPTION + "The sdlcCorePortOperGroup defines objects + which are common to the PortOper group of all + compliant link stations." + ::= { sdlcCoreGroups 5 } + + +sdlcCoreLSStatsGroup OBJECT-GROUP + OBJECTS + { + sdlcLSStatsBLUsIn, + sdlcLSStatsBLUsOut, + sdlcLSStatsOctetsIn, + sdlcLSStatsOctetsOut, + sdlcLSStatsPollsIn, + sdlcLSStatsPollsOut, + sdlcLSStatsPollRspsIn, + sdlcLSStatsPollRspsOut, + sdlcLSStatsLocalBusies, + sdlcLSStatsRemoteBusies, + sdlcLSStatsIFramesIn, + sdlcLSStatsIFramesOut, + sdlcLSStatsRetransmitsIn, + sdlcLSStatsRetransmitsOut, + sdlcLSStatsUIFramesIn, + sdlcLSStatsUIFramesOut, + sdlcLSStatsXIDsIn, + sdlcLSStatsXIDsOut, + sdlcLSStatsTESTsIn, + sdlcLSStatsTESTsOut, + sdlcLSStatsREJsIn, + + + +Hilgeman, Nix, Bartky & Clark [Page 63] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + sdlcLSStatsREJsOut, + sdlcLSStatsFRMRsIn, + sdlcLSStatsFRMRsOut, + sdlcLSStatsSIMsIn, + sdlcLSStatsSIMsOut, + sdlcLSStatsRIMsIn, + sdlcLSStatsRIMsOut, + sdlcLSStatsProtocolErrs, + sdlcLSStatsRNRLIMITs, + sdlcLSStatsRetriesExps + } + STATUS current + DESCRIPTION + "The sdlcCorePortStatsGroup defines objects + which are common to the PortStats group of all + compliant link stations." + ::= { sdlcCoreGroups 6 } + + +-- +-- Conformance Groups for Primary Link Stations +-- + +sdlcPrimaryGroups OBJECT IDENTIFIER ::= { sdlcGroups 2 } + +sdlcPrimaryGroup OBJECT-GROUP + OBJECTS + { + sdlcPortAdminPAUSE, + sdlcPortOperPAUSE, + sdlcLSAdminREPLYTO, + sdlcLSOperREPLYTO + } + STATUS current + DESCRIPTION + "The sdlcPrimaryGroup defines objects which + are common to all compliant primary link + stations." + ::= { sdlcPrimaryGroups 1 } + +sdlcPrimaryMultipointGroup OBJECT-GROUP + OBJECTS + { + sdlcPortAdminSERVLIM, + sdlcPortAdminSlowPollTimer, + sdlcPortOperSlowPollMethod, + sdlcPortOperSERVLIM, + sdlcPortOperSlowPollTimer + + + +Hilgeman, Nix, Bartky & Clark [Page 64] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + } + STATUS current + DESCRIPTION + "The sdlcPrimaryMultipointGroup defines objects + which are common to all compliant primary link + stations that are in a multipoint topology." + ::= { sdlcPrimaryGroups 2 } + + +END + +4. Acknowledgments + + Thanks goes to the SNADLC MIB working group for reviewing this MIB + and for their infinite patience through the editing process. + +5. References + + [1] Stewart, B., "Definitions of Managed Objects for RS-232-like + Hardware Devices using SMIv2", RFC 1659, Xyplex, July 1994. + + [2] "Synchronous Data Link Control: Concepts", IBM Publication No. + GA27-3093-04, 5th edition, May 1992. + + [3] "Vocabulary for Data Processing Telecommunications, and Office + Systems", IBM Publication No. GC20-1699-6. + + [4] Kostick, D., Kielczewski, Z., and K. Shih, Editors, "Definitions + of Managed Objects for SNA NAUs using SMIv2", RFC 1666, Eicon + Technology Corporation, Bell Communications Research, Novell, + August 1994. + + [5] Waldbusser, S., "Row Creation with SNMPv1", Work in Progress. + + [6] McCloghrie K., and F. Kastenholz, "Evolution of the Interfaces + Group of MIB-II", RFC 1573, Hughes LAN Syst, FTP Software, + January 1994. + + + + + + + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 65] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + +6. Glossary + + link station + A link station comprises procedures and control information + that coordinate the transfer of data between two nodes joined + by a link connection. All traffic over the link connection is + from the primary link station to one or more secondary link + stations, or from a secondary link station to the primary link + station. + + primary link station + The link station instance on a link connection that is + responsible for the control of the data link. There must be + only one primary link station on a link connection. The + primary link station issues commands to one or more secondary + link stations. + + secondary link station + The link station instance on a link connection that receives + commands from the primary link station and issues responses to + it. + + switched line + A telecommunications line in which the connection is + established by dialing. For switched lines, the SDLC startup + sequence typically begins with a null exchange identifier (null + XID). + + leased line + A telecommunications line on which connections do not have to + be established by dialing. For leased lines, the SDLC startup + sequence may or may not begin with an exchange identifer (XID). + While there are interface (e.g., RS.232) differences between + leased and switched lines, those interface differences do not + map one-to-one with differences in the SDLC startup protocol + (i.e., the interface and the SDLC protocol are independent from + one another). + + point-to-point link + A link that connects the single primary link station to single + secondary link station. A point-to-point link may be either + switched or leased. + + multipoint link + A link that connects the single primary link station to several + secondary link stations. A multipoint link may be either + switched or leased. Note: The physical interface signals for a + multipoint link are different than for a point-to-point link. + + + +Hilgeman, Nix, Bartky & Clark [Page 66] + +RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995 + + + Synonymous with multidrop line. + +7. Security Considerations + + Security issues are not discussed in this memo. + +8. Authors' Addresses + + Jeff Hilgeman (chair) + Apertus Technologies, Inc. + 7275 Flying Cloud Dr. + Eden Prarie, MN 55344 + + Phone: 1 612 828 0668 + EMail: jeffh@apertus.com + + + Shannon D. Nix + Metaplex, Inc. + 7412 Wingfoot Dr. + Raleigh, NC 27615 + + Phone: 1 919 878 0811 + EMail: snix@metaplex.com + + + Alan Bartky + Sync Research, Inc. + 7 Studebaker + Irvine, CA 92718 + + Phone: 1 714 588 2070 + EMail: alan@sync.com + + + Wayne Clark (editor) + cisco Systems, Inc. + 3100 Smoketree Ct. + Suite 1000 + Raleigh, NC 27604 + + Phone: 1 919 878 6958 + EMail: wclark@cisco.com + + + + + + + + +Hilgeman, Nix, Bartky & Clark [Page 67] + |