summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc5815.txt
diff options
context:
space:
mode:
authorThomas Voss <mail@thomasvoss.com> 2024-11-27 20:54:24 +0100
committerThomas Voss <mail@thomasvoss.com> 2024-11-27 20:54:24 +0100
commit4bfd864f10b68b71482b35c818559068ef8d5797 (patch)
treee3989f47a7994642eb325063d46e8f08ffa681dc /doc/rfc/rfc5815.txt
parentea76e11061bda059ae9f9ad130a9895cc85607db (diff)
doc: Add RFC documents
Diffstat (limited to 'doc/rfc/rfc5815.txt')
-rw-r--r--doc/rfc/rfc5815.txt3587
1 files changed, 3587 insertions, 0 deletions
diff --git a/doc/rfc/rfc5815.txt b/doc/rfc/rfc5815.txt
new file mode 100644
index 0000000..b90dfd6
--- /dev/null
+++ b/doc/rfc/rfc5815.txt
@@ -0,0 +1,3587 @@
+
+
+
+
+
+
+Internet Engineering Task Force (IETF) T. Dietz, Ed.
+Request for Comments: 5815 NEC Europe, Ltd.
+Category: Standards Track A. Kobayashi
+ISSN: 2070-1721 NTT PF Labs.
+ B. Claise
+ Cisco Systems, Inc.
+ G. Muenz
+ Technische Universitaet Muenchen
+ April 2010
+
+
+ Definitions of Managed Objects for IP Flow Information Export
+
+Abstract
+
+ This document defines managed objects for IP Flow Information eXport
+ (IPFIX). These objects provide information for monitoring IPFIX
+ Exporters and IPFIX Collectors including the basic configuration
+ information.
+
+Status of This Memo
+
+ This is an Internet Standards Track document.
+
+ This document is a product of the Internet Engineering Task Force
+ (IETF). It represents the consensus of the IETF community. It has
+ received public review and has been approved for publication by the
+ Internet Engineering Steering Group (IESG). Further information on
+ Internet Standards is available in Section 2 of RFC 5741.
+
+ Information about the current status of this document, any errata,
+ and how to provide feedback on it may be obtained at
+ http://www.rfc-editor.org/info/rfc5815.
+
+Copyright Notice
+
+ Copyright (c) 2010 IETF Trust and the persons identified as the
+ document authors. All rights reserved.
+
+ This document is subject to BCP 78 and the IETF Trust's Legal
+ Provisions Relating to IETF Documents
+ (http://trustee.ietf.org/license-info) in effect on the date of
+ publication of this document. Please review these documents
+ carefully, as they describe your rights and restrictions with respect
+ to this document. Code Components extracted from this document must
+ include Simplified BSD License text as described in Section 4.e of
+ the Trust Legal Provisions and are provided without warranty as
+ described in the Simplified BSD License.
+
+
+
+Dietz, et al. Standards Track [Page 1]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+Table of Contents
+
+ 1. Introduction ....................................................3
+ 2. IPFIX Documents Overview ........................................3
+ 3. The Internet-Standard Management Framework ......................4
+ 4. Terminology .....................................................4
+ 5. Structure of the IPFIX MIB ......................................4
+ 5.1. The Transport Session Table ................................4
+ 5.2. The Template Table .........................................7
+ 5.3. The Template Definition Table ..............................9
+ 5.4. The Export Table ..........................................11
+ 5.5. The Metering Process Table ................................12
+ 5.6. The Observation Point Table ...............................13
+ 5.7. The Selection Process Table ...............................14
+ 5.8. The Statistical Tables ....................................15
+ 5.8.1. The Transport Session Statistical Table ............15
+ 5.8.2. The Template Statistical Table .....................15
+ 5.8.3. The Metering Process Statistical Table .............15
+ 5.8.4. The Selection Process Statistical Table ............15
+ 6. Structure of the IPFIX SELECTOR MIB ............................15
+ 6.1. The Selector Functions ....................................16
+ 7. Relationship to Other MIB Modules ..............................18
+ 7.1. Relationship to the ENTITY MIB and IF MIB .................18
+ 7.2. MIB Modules Required for IMPORTS ..........................18
+ 8. MIB Definitions ................................................18
+ 8.1. IPFIX MIB Definition ......................................19
+ 8.2. IPFIX SELECTOR MIB Definition .............................56
+ 9. Security Considerations ........................................60
+ 10. IANA Considerations ...........................................61
+ 11. Acknowledgments ...............................................61
+ 12. References ....................................................62
+ 12.1. Normative References .....................................62
+ 12.2. Informative References ...................................63
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 2]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+1. Introduction
+
+ This document defines two MIB modules for monitoring IP Flow
+ Information eXport (IPFIX) Devices including Exporters and
+ Collectors. Most of the objects defined by the IPFIX MIB module MUST
+ be implemented. Some objects MAY be implemented corresponding to the
+ functionality implemented in the equipment. Since the IPFIX
+ architecture [RFC5470] foresees the possibility of using Filtering
+ and/or Sampling functions to reduce the data volume, this document
+ also provides the IPFIX SELECTOR MIB module, which contains the
+ standardized selection methods and is controlled by IANA. The full
+ configuration of the IPFIX Metering Process is out of the scope of
+ these MIB modules.
+
+ The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
+ "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
+ document are to be interpreted as described in RFC 2119 [RFC2119].
+
+2. IPFIX Documents Overview
+
+ The IPFIX protocol provides network administrators with access to IP
+ Flow information. The architecture for the export of measured IP
+ Flow information out of an IPFIX Exporting Process to a Collecting
+ Process is defined in [RFC5470], per the requirements defined in
+ [RFC3917]. The protocol document [RFC5101] specifies how IPFIX Data
+ Records and Templates are carried via a congestion-aware transport
+ protocol from IPFIX Exporting Processes to IPFIX Collecting
+ Processes. IPFIX has a formal description of IPFIX Information
+ Elements, their name, type and additional semantic information, as
+ specified in [RFC5102]. Finally, [RFC5472] describes what type of
+ applications can use the IPFIX protocol and how they can use the
+ information provided. It furthermore shows how the IPFIX framework
+ relates to other architectures and frameworks.
+
+ It is assumed that Flow metering, export, and collection is performed
+ according to the IPFIX architecture defined in [RFC5470]. The
+ monitored configuration parameters of the export and collection of
+ Flow Templates and Data Records is modeled according to [RFC5101].
+ Packet selection methods that may be optionally used by the IPFIX
+ Metering Process are not considered in this MIB module. They are
+ defined in the Packet Sampling (PSAMP) framework [RFC5474] and
+ Sampling techniques [RFC5475] documents. Nevertheless, the basis for
+ defining Sampling and Filtering functions is given with the IPFIX
+ SELECTOR MIB module. Since the PSAMP export protocol [RFC5476] is
+ based on the IPFIX protocol, the Sampling and Filtering functions can
+ be added to the IPFIX SELECTOR MIB module as needed.
+
+
+
+
+
+Dietz, et al. Standards Track [Page 3]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+3. The Internet-Standard Management Framework
+
+ For a detailed overview of the documents that describe the current
+ Internet-Standard Management Framework, please refer to section 7 of
+ RFC 3410 [RFC3410].
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. MIB objects are generally
+ accessed through the Simple Network Management Protocol (SNMP).
+ Objects in the MIB are defined using the mechanisms defined in the
+ Structure of Management Information (SMI). This memo specifies MIB
+ modules that are compliant to the SMIv2, which is described in STD
+ 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC
+ 2580 [RFC2580].
+
+4. Terminology
+
+ The definitions of the basic terms like IP Traffic Flow, Exporting
+ Process, Collecting Process, Observation Points, etc. can be found in
+ the IPFIX protocol document [RFC5101].
+
+5. Structure of the IPFIX MIB
+
+ The IPFIX MIB module consists of seven main tables, the Transport
+ Session table, the Template table and the corresponding Template
+ Definition table, the Export table, the Metering Process table, the
+ Observation Point table, and the Selection Process table. Since the
+ IPFIX architecture [RFC5470] foresees the possibility of using
+ Filtering and/or Sampling functions to reduce the data volume, the
+ MIB module provides the basic objects for these functions with the
+ Selection Process table. The IPFIX SELECTOR MIB module defined in
+ the next section provides the standard Filtering and Sampling
+ functions that can be referenced in the ipfixSelectionProcessTable.
+
+ All remaining objects contain statistical values for the different
+ tables contained in the MIB module.
+
+ The following subsections describe all tables in the IPFIX MIB
+ module.
+
+5.1. The Transport Session Table
+
+ The Transport Session is the basis of the MIB module. The Transport
+ Session table (ipfixTransportSessionTable) contains all Transport
+ Sessions between Exporter and Collector. The table specifies the
+ transport layer protocol of the Transport Session and, depending on
+ that protocol, further parameters for the Transport Session. In the
+ case of UDP and TCP, these are the source and destination address as
+
+
+
+Dietz, et al. Standards Track [Page 4]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ well as the source and destination port. For Stream Control
+ Transmission Protocol (SCTP), the table contains the SCTP Assoc Id,
+ which is the index for the SCTP association in the SCTP MIB module
+ [RFC3873]. The mode of operation of the device, i.e., if the
+ Transport Session is used for collecting or exporting is given in the
+ ipfixTransportSessionDeviceMode object. Further on, it contains the
+ configured refresh parameters for Templates and Options Templates
+ that are used across unreliable connections as UDP. Finally, the
+ IPFIX version that is exported or collected by this Transport Session
+ and a status of the Transport Session is given in the table.
+
+ To illustrate the use of the above tables, let us assume the
+ following scenario: we have an Exporter on IP address 192.0.2.22 and
+ a Collector on IP address 192.0.2.37. The Exporter uses TCP to
+ export Templates and Data Records. The same Exporter also exports,
+ with UDP, to a Collector with the IP address of 192.0.2.44. This
+ would lead to the following Transport Session table on the Exporter:
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 5]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTransportSessionTable (1)
+ |
+ +- ipfixTransportSessionEntry (1)
+ |
+ +- index (5) (ipfixTransportSessionIndex)
+ | +- ipfixTransportSessionIndex (1) = 5
+ | +- ipfixTransportSessionProtocol (2) = 6 (TCP)
+ | +- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
+ | +- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
+ | +- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
+ | +- ipfixTransportSessionDestinationAddress (6) = 192.0.2.37
+ | +- ipfixTransportSessionSourcePort (7) = 7653
+ | +- ipfixTransportSessionDestinationPort (8) = 4739
+ | +- ipfixTransportSessionSctpAssocId (9) = 0
+ | +- ipfixTransportSessionDeviceMode (10) = exporting(1)
+ | +- ipfixTransportSessionTemplateRefreshTimeout (11) = 0
+ | +- ipfixTransportSessionOptionTemplateRefreshTimeout (12) = 0
+ | +- ipfixTransportSessionTemplateRefreshPacket (13) = 0
+ | +- ipfixTransportSessionOptionTemplateRefreshPacket (14) = 0
+ | +- ipfixTransportSessionIpfixVersion (15) = 10
+ | +- ipfixTransportSessionStatus (16) = 2 (active)
+ .
+ .
+ .
+ +- index (11) (ipfixTransportSessionIndex)
+ +- ipfixTransportSessionIndex (1) = 11
+ +- ipfixTransportSessionProtocol (2) = 17 (UDP)
+ +- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
+ +- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
+ +- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
+ +- ipfixTransportSessionDestinationAddress (6) = 192.0.2.44
+ +- ipfixTransportSessionSourcePort (7) = 14287
+ +- ipfixTransportSessionDestinationPort (8) = 4739
+ +- ipfixTransportSessionSctpAssocId (9) = 0
+ +- ipfixTransportSessionDeviceMode (10) = exporting(1)
+ +- ipfixTransportSessionTemplateRefreshTimeout (11) = 100
+ +- ipfixTransportSessionOptionTemplateRefreshTimeout (12)
+ | = 100
+ +- ipfixTransportSessionTemplateRefreshPacket (13) = 10
+ +- ipfixTransportSessionOptionTemplateRefreshPacket (14) = 10
+ +- ipfixTransportSessionIpfixVersion (15) = 10
+ +- ipfixTransportSessionStatus (16) = 2 (active)
+
+ The values in brackets are the OID numbers. The Collectors would
+ then have the same entry except that the index would most likely
+ differ and the ipfixTransportSessionDeviceMode would be
+ collecting(2).
+
+
+
+
+Dietz, et al. Standards Track [Page 6]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+5.2. The Template Table
+
+ The Template table lists all Templates (including Options Templates)
+ that are sent (by an Exporter) or received (by a Collector). The
+ (Options) Templates are unique per Transport Session, which also
+ gives the device mode (Exporter or Collector) and Observation Domain;
+ thus, the table is indexed by:
+
+ o the Transport Session Index (ipfixTransportSessionIndex)
+
+ o and the Observation Domain Id (ipfixTemplateObservationDomainId).
+
+ It contains the Set Id and an access time denoting the time when the
+ (Options) Template was last sent or received.
+
+ To resume the above example, the Exporter may want to export a
+ Template and an Options Template for each Transport Session defined
+ above. This leads to the following Template table defining Template
+ and Options Template:
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 7]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateTable (3)
+ |
+ +- ipfixTemplateEntry (1)
+ |
+ +- index (5) (ipfixTransportSessionIndex)
+ | +- index (3) (ipfixTemplateObservationDomainId)
+ | + index (257) (ipfixTemplateId)
+ | | +- ipfixTemplateObservationDomainId (1) = 3
+ | | +- ipfixTemplateId (2) = 257
+ | | +- ipfixTemplateSetId (3) = 2
+ | | +- ipfixTemplateAccessTime (4)
+ | | = 2008-7-1,12:49:11.2,+2:0
+ | |
+ | + index (264) (ipfixTemplateId)
+ | +- ipfixTemplateObservationDomainId (1) = 3
+ | +- ipfixTemplateId (2) = 264
+ | +- ipfixTemplateSetId (3) = 3
+ | +- ipfixTemplateAccessTime (4)
+ . = 2008-7-1,12:47:04.8,+2:0
+ .
+ .
+ .
+ +- index (11) (ipfixTransportSessionIndex)
+ +- index (3) (ipfixTemplateObservationDomainId)
+ + index (273) (ipfixTemplateId)
+ | +- ipfixTemplateObservationDomainId (1) = 3
+ | +- ipfixTemplateId (2) = 273
+ | +- ipfixTemplateSetId (3) = 2
+ | +- ipfixTemplateAccessTime (4)
+ | = 2008-7-1,12:49:11.2,+2:0
+ |
+ + index (289) (ipfixTemplateId)
+ +- ipfixTemplateObservationDomainId (1) = 3
+ +- ipfixTemplateId (2) = 289
+ +- ipfixTemplateSetId (3) = 3
+ +- ipfixTemplateAccessTime (4)
+ = 2008-7-1,12:47:04.8,+2:0
+
+ We assume that the Transport Session that is stored with index 5 in
+ the Transport Session table of the Exporter is stored with index 17
+ in the Transport Session table of the (corresponding) Collector.
+ Then, the Template table would look as follows:
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 8]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateTable (3)
+ |
+ +- ipfixTemplateEntry (1)
+ |
+ +- index (17) (ipfixTransportSessionIndex)
+ +- index (3) (ipfixTemplateObservationDomainId)
+ + index (257) (ipfixTemplateId)
+ | +- ipfixTemplateObservationDomainId (1) = 3
+ | +- ipfixTemplateId (2) = 257
+ | +- ipfixTemplateSetId (3) = 2
+ | +- ipfixTemplateAccessTime (4)
+ | = 2008-7-1,12:49:11.8,+2:0
+ |
+ + index (264) (ipfixTemplateId)
+ +- ipfixTemplateObservationDomainId (1) = 3
+ +- ipfixTemplateId (2) = 264
+ +- ipfixTemplateSetId (3) = 3
+ +- ipfixTemplateAccessTime (4)
+ = 2008-7-1,12:47:05.3,+2:0
+
+ The table on the second Collector would be analogous to the one shown
+ above.
+
+5.3. The Template Definition Table
+
+ The Template Definition table lists all the Information Elements
+ contained in a Template or Options Template. Therefore, it has the
+ same indexes as the corresponding Template table plus the Template
+ Id. Its own index denotes the order of the Information Element
+ inside the Template. Besides the Information Element Id and the
+ length of the encoded value, the table contains the enterprise number
+ for enterprise-specific Information Elements and flags for each
+ Information Element. The flags indicate if the Information Element
+ is used for scoping or as a Flow Key.
+
+ To resume the above example again, the Exporter is configured to
+ export the octets received and dropped at the Observation Point since
+ the last export of these values. In addition, it exports the start
+ and end time of the Flow relative to the timestamp contained in the
+ IPFIX header. This leads to the following Template Definition table
+ on the Exporter:
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 9]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateDefinitionTable (4)
+ |
+ +- ipfixTemplateDefinitionEntry (1)
+ |
+ +- index (5) (ipfixTransportSessionIndex)
+ +- index (3) (ipfixTemplateObservationDomainId)
+ + index (257) (ipfixTemplateId)
+ +- index (1) (ipfixTemplateDefinitionIndex)
+ | +- ipfixTemplateDefinitionIndex (1) = 1
+ | +- ipfixTemplateDefinitionIeId (2) = 158
+ | | (flowStartDeltaMicroseconds)
+ | +- ipfixTemplateDefinitionIeLength (3) = 4
+ | +- ipfixTemplateDefinitionEnterprise (4) = 0
+ | +- ipfixTemplateDefinitionFlags (5) = 0
+ |
+ +- index (2) (ipfixTemplateDefinitionIndex)
+ | +- ipfixTemplateDefinitionIndex (1) = 2
+ | +- ipfixTemplateDefinitionIeId (2) = 159
+ | | (flowEndDeltaMicroseconds)
+ | +- ipfixTemplateDefinitionIeLength (3) = 4
+ | +- ipfixTemplateDefinitionEnterprise (4) = 0
+ | +- ipfixTemplateDefinitionFlags (5) = 0
+ |
+ +- index (3) (ipfixTemplateDefinitionIndex)
+ | +- ipfixTemplateDefinitionIndex (1) = 3
+ | +- ipfixTemplateDefinitionIeId (2) = 1
+ | | (octetDeltaCount)
+ | +- ipfixTemplateDefinitionIeLength (3) = 8
+ | +- ipfixTemplateDefinitionEnterprise (4) = 0
+ | +- ipfixTemplateDefinitionFlags (5) = 0
+ |
+ +- index (4) (ipfixTemplateDefinitionIndex)
+ +- ipfixTemplateDefinitionIndex (1) = 4
+ +- ipfixTemplateDefinitionIeId (2) = 132
+ | (droppedOctetDeltaCount)
+ +- ipfixTemplateDefinitionIeLength (3) = 8
+ +- ipfixTemplateDefinitionEnterprise (4) = 0
+ +- ipfixTemplateDefinitionFlags (5) = 0
+
+ The corresponding table entry on the Collector is the same except
+ that it would have another ipfixTransportSessionIndex, e.g., 17 as in
+ the previous example.
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 10]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+5.4. The Export Table
+
+ On Exporters, the Export table (ipfixExportTable) can be used to
+ support features like failover, load-balancing, duplicate export to
+ several Collectors, etc. The table has three indexes that link an
+ entry with:
+
+ o the Metering Process table (ipfixMeteringProcessCacheId, see
+ below)
+
+ o and the Transport Session table (ipfixTransportSessionIndex).
+
+ Those entries with the same ipfixExportIndex and the same
+ ipfixMeteringProcessCacheId define a Transport Session group. The
+ member type for each group member describes its functionality. All
+ Transport Sessions referenced in this table MUST have the
+ ipfixTransportSessionDeviceMode exporting(1).
+
+ If the Exporter does not use Transport Session grouping, then each
+ ipfixExportIndex contains a single ipfixMeteringProcessCacheId, and
+ thus a singe Transport Session (ipfixTransportSessionIndex) and this
+ session MUST have the member type primary(1).
+
+ For failover, a Transport Session group can contain one Transport
+ Session with member type "primary" and several Transport Sessions
+ with type secondary(2). Entries with other member types are not
+ allowed for that type of group. For load-balancing or parallel
+ export, all Transport Sessions in the group MUST have the same member
+ type, either loadBalancing(4) or parallel(3).
+
+ The algorithms used for failover or load-balancing are out of the
+ scope of this document.
+
+ To continue the example, we assume that the Exporter uses the two
+ connections shown in the examples above as one primary Transport
+ Session protected by a secondary Transport Session. The Exporter
+ then has the following entries in the ipfixExportTable:
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 11]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixExportTable (5)
+ |
+ +- ipfixExportEntry (1)
+ |
+ +- index (7) (ipfixExportIndex)
+ | +- index (9) (ipfixMeteringProcessCacheId)
+ | | +- index (5) (ipfixTransportSessionIndex)
+ | | +- ipfixExportIndex (1) = 7
+ | | +- ipfixExportMemberType (2) = 1 (primary)
+ | |
+ | +- index (11) (ipfixTransportSessionIndex)
+ | +- ipfixExportIndex (1) = 7
+ | +- ipfixExportMemberType (2) = 2 (secondary)
+ |
+ +- index (8) (ipfixExportIndex)
+ +- index (9) (ipfixMeteringProcessCacheId)
+ +- index (5) (ipfixTransportSessionIndex)
+ | +- ipfixExportIndex (1) = 8
+ | +- ipfixExportMemberType (2) = 2 (secondary)
+ +- index (11) (ipfixTransportSessionIndex)
+ +- ipfixExportIndex (1) = 8
+ +- ipfixExportMemberType (2) = 1 (primary)
+
+ The example shows that the Exporter uses the Metering Process Cache
+ 9, explained below, to export IPFIX Data Records for the Transport
+ Sessions 5 and 11. The Templates 257 and 264 defined above are
+ exported within Transport Session 5, and the Templates 273 and 289
+ are exported within Transport Session 11. If we assume that
+ Templates 257 and 264 are identical, then the Collector that receives
+ Transport Session 11 is a backup for the Collector of Transport
+ Session 5.
+
+5.5. The Metering Process Table
+
+ The Metering Process, as defined in [RFC5101], consists of a set of
+ functions. Maintaining the Flow Records is one of them. This
+ function is responsible for passing the Flow Records to the Exporting
+ Process and also for detecting Flow expiration. The Flow Records
+ that are maintained by the Metering Process can be grouped by the
+ Observation Points at which they are observed. The instance that
+ maintains such a group of Flow Records is a kind of cache. For this
+ reason, the Metering Process table (ipfixMeteringProcessTable) is
+ indexed by cache Ids (ipfixMeteringProcessCacheId). Each cache can
+ be maintained by a separate instance of the Metering Process. To
+ specify the Observation Point(s) where the Flow Records are gathered,
+ the ipfixMeteringProcessObservationPointGroupRef may contain an
+ ipfixObservationPointGroupId from the Observation Point table
+ (ipfixObservationPointTable) described in the next section. If an
+
+
+
+Dietz, et al. Standards Track [Page 12]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ Observation Point is not specified for the Flow Records, the
+ ipfixMeteringProcessObservationPointGroupRef MUST be zero(0). The
+ timeouts (ipfixMeteringProcessCacheActiveTimeout and
+ ipfixMeteringProcessCacheInactiveTimeout) specify when Flows are
+ expired.
+
+ ipfixMeteringProcessTable (6)
+ |
+ +- ipfixMeteringProcessEntry (1)
+ |
+ +- index (9) (ipfixMeteringProcessCacheId)
+ +- ipfixMeteringProcessCacheId (1) = 9
+ +- ipfixMeteringProcessObservationPointGroupRef (2) = 17
+ +- ipfixMeteringProcessCacheActiveTimeout (3) = 100
+ +- ipfixMeteringProcessCacheInactiveTimeout (4) = 100
+
+5.6. The Observation Point Table
+
+ The Observation Point table (ipfixObservationPointTable) groups
+ Observation Points with the ipfixObservationPointGroupId. Each entry
+ contains the Observation Domain Id in which the Observation Point is
+ located and a reference to the ENTITY MIB module [RFC4133] or the IF
+ MIB module [RFC2863]. The objects in the ENTITY MIB module
+ referenced by ipfixObservationPointPhysicalEntity or IF MIB module
+ referenced by ipfixObservationPointPhysicalInterface denote the
+ Observation Point. If no such index can be given in those modules,
+ the references MUST be 0. If a reference is given in both object
+ ipfixObservationPointPhysicalEntity and
+ ipfixObservationPointPhysicalInterface, then both MUST point to the
+ same physical interface. In addition, a direction can be given to
+ render more specifically which Flow to monitor.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 13]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixObservationPointTable (7)
+ |
+ +- ipfixObservationPointEntry (1)
+ |
+ +- index (17) (ipfixObservationPointGroupId)
+ +- index (1) (ipfixObservationPointIndex)
+ | +- ipfixObservationPointGroupId (1) = 17
+ | +- ipfixObservationPointIndex (2) = 1
+ | +- ipfixObservationPointObservationDomainId (3) = 3
+ | +- ipfixObservationPointPhysicalEntity (4) = 6
+ | +- ipfixObservationPointPhysicalInterface(5) = 0
+ | +- ipfixObservationPointPhysicalEntityDirection (6)
+ = 3 (both)
+ |
+ +- index (2) (ipfixObservationPointIndex)
+ +- ipfixObservationPointGroupId (1) = 17
+ +- ipfixObservationPointIndex (2) = 2
+ +- ipfixObservationPointObservationDomainId (3) = 3
+ +- ipfixObservationPointPhysicalEntity (4) = 0
+ +- ipfixObservationPointPhysicalInterface (5) = 0
+ +- ipfixObservationPointPhysicalEntityDirection (6)
+ = 1 (ingress)
+
+5.7. The Selection Process Table
+
+ This table supports the usage of Filtering and Sampling functions, as
+ described in [RFC5470]. It contains lists of functions per Metering
+ Process cache (ipfixMeteringProcessCacheId). The selection process
+ index ipfixSelectionProcessIndex forms groups of selection methods
+ that are applied to an observed packet stream. The selection process
+ selector index (ipfixSelectionProcessSelectorIndex) indicates the
+ order in which the functions are applied to the packets observed at
+ the Observation Points associated with the Metering Process cache.
+ The selection methods are applied in increasing order, i.e.,
+ selection methods with a lower ipfixSelectionProcessSelectorIndex are
+ applied first. The functions are referred by object identifiers
+ pointing to the function with its parameters. If the selection
+ method does not use parameters, then it MUST point to the root of the
+ function subtree (see also Section 6). If the function uses
+ parameters, then it MUST point to an entry in the parameter table of
+ the selection method. If no Filtering or Sampling function is used
+ for a Metering Process, then an entry for the Metering Process SHOULD
+ be created pointing to the Select All function (ipfixFuncSelectAll).
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 14]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+5.8. The Statistical Tables
+
+ For the ipfixTransportSessionTable, the ipfixTemplateTable, the
+ ipfixMeteringProcessTable, and the ipfixSelectionProcessTable
+ statistical tables are defined that augment those tables. All the
+ statistical tables contain a discontinuity object that holds a
+ timestamp that denotes the time when a discontinuity event occurred
+ to notify the management system that the counters contained in those
+ tables might not be continuous anymore.
+
+5.8.1. The Transport Session Statistical Table
+
+ The Transport Session Statistical table
+ (ipfixTransportSessionStatsTable) augments the
+ ipfixTransportSessionTable with statistical values. It contains the
+ rate (in bytes per second) with which it receives or sends out IPFIX
+ Messages, the number of bytes, packets, messages, Records, Templates
+ and Options Templates received or sent and the number of messages
+ that were discarded.
+
+5.8.2. The Template Statistical Table
+
+ This table contains a statistical value for each Template. It
+ augments the Template table (ipfixTemplateTable) and specifies the
+ number of Data Records exported or collected for the Template.
+
+5.8.3. The Metering Process Statistical Table
+
+ This table augments the Metering Process table
+ (ipfixMeteringProcessTable). It contains the statistical values for
+ the exported Data Records and the number of unused cache entries.
+
+5.8.4. The Selection Process Statistical Table
+
+ This table augments the Selection Process table
+ (ipfixSelectionProcessTable) and introduces two generic statistical
+ values, the number of packets observed and the number of packets
+ dropped by the selection method.
+
+6. Structure of the IPFIX SELECTOR MIB
+
+ The IPFIX SELECTOR MIB module defined in this section provides the
+ standard Filtering and Sampling functions that can be referenced in
+ the ipfixSelectionProcessTable. The subtree ipfixSelectorFunctions
+ is a placeholder where all standard Filtering and Sampling functions
+ should be located. It currently contains the Select All function
+ (ipfixFuncSelectAll). The IPFIX SELECTOR MIB module is maintained by
+ IANA and can be extended through Expert Review [RFC5226], i.e.,
+
+
+
+Dietz, et al. Standards Track [Page 15]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ review by one of a group of experts designated by an IETF Area
+ Director. The group of experts MUST check the requested MIB objects
+ for completeness and accuracy of the description. Requests for MIB
+ objects that duplicate the functionality of existing objects SHOULD
+ be declined. The smallest available OID SHOULD be assigned to a new
+ MIB objects. The specification of new MIB objects SHOULD follow the
+ structure specified in the next Section and MUST be published using a
+ well-established and persistent publication medium. The experts will
+ initially be drawn from the Working Group Chairs and document editors
+ of the IPFIX and PSAMP Working Groups.
+
+6.1. The Selector Functions
+
+ The following figure shows what the MIB tree usually should look
+ like. It already contains the ipfixFuncSelectAll. The subtree in
+ ipfixFuncF2 gives the basic structure that all selection methods
+ SHOULD follow.
+
+ ipfixSelectorFunctions
+ |
+ +- ipfixFuncSelectAll
+ | |
+ | +- ipfixFuncSelectAllAvail (is the function available?)
+ |
+ +- ipfixFuncF2
+ | |
+ | +- ipfixFuncF2Avail (is the function F2 available?)
+ | |
+ | +- ipfixFuncF2Parameters (a table with parameters)
+ ...
+ |
+ +- ipfixFunFn...
+
+ The selection method SHOULD be designed as a MIB subtree introduced
+ by an object with the name ipfixFunc appended by a function name.
+ The objects in this subtree SHOULD be prefixed by this name. If the
+ function is named Fx, then we would start a subtree with an OID named
+ ipfixFuncFx. This subtree should contain an object ipfixFuncFxAvail
+ that has the type TruthValue. If a selection method takes
+ parameters, the MIB should contain a table named
+ ipfixFuncFxParameters, which should contain all the parameters that
+ the selection method specifies. An entry in this table will be
+ referenced by the IPFIX MIB module if the selection method with the
+ parameters is used.
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 16]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ To illustrate the structure defined above, the following contains an
+ example of a function MyFunc that holds three integer parameters
+ Param1, Param2, and Param3. In the example, there are currently two
+ instances of the parameters set defined with indexes 1 and 4.
+
+ ipfixSelectorFunctions (1)
+ |
+ +- ipfixFuncMyFunc (?)
+ |
+ +- ipfixFuncMyFuncAvail (1) = true
+ +- ipfixFuncMyFuncParameters (2)
+ |
+ +- ipfixFuncMyFuncParametersEntry (1)
+ |
+ +- index (1) (ipfixFuncMyFuncParametersIndex)
+ | +- ipfixFuncMyFuncParam1 (1) = 47
+ | +- ipfixFuncMyFuncParam2 (2) = -128
+ | +- ipficFuncMyFuncParam3 (3) = 19
+ |
+ +- index(4) (ipfixFuncMyFuncParametersIndex)
+ +- ipfixFuncMyFuncParam1 (1) = 19
+ +- ipfixFuncMyFuncParam2 (2) = -1
+ +- ipficFuncMyFuncParam3 (3) = 728
+
+ If the function defined above is referenced in the IPFIX MIB module,
+ the ipfixSelectionProcessTable would look as follows:
+
+ ipfixSelectionProcessTable (8)
+ |
+ +- ipfixSelectionProcessEntry (1)
+ |
+ +- index (9) (ipfixMeteringProcessCacheId)
+ +- index (1) (ipfixSelectionProcessIndex)
+ +- index (1) (ipfixSelectionProcessSelectorIndex)
+ | +- ipfixSelectionProcessSelectorFunction (3)
+ | = ipfixSelectorFunctions.?.2.1.4
+ +- index (2) (ipfixSelectionProcessSelectorIndex)
+ +- ipfixSelectionProcessSelectorFunction (3)
+ = ipfixSelectorFunctions.?.2.1.1
+
+ This means that for the ipfixMeteringProcessCacheId(9), a Selection
+ Process with index 1 is created that applies two times the same
+ function but with different parameter sets. First, the function
+ MyFunc is applied with the parameters of the set with index 4 and the
+ with the parameters of the set with index 1.
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 17]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+7. Relationship to Other MIB Modules
+
+ Besides the usual imports from the SNMP Standards [RFC2578],
+ [RFC2579], and [RFC2580], the IPFIX MIB module references the ENTITY
+ MIB module [RFC4133] and the IF MIB module [RFC2863].
+
+7.1. Relationship to the ENTITY MIB and IF MIB
+
+ The Observation Point table (ipfixObservationPointTable) contains a
+ reference to the ENTITY MIB module[RFC4133]
+ (ipfixObservationPointPhysicalEntity) or the IF MIB module [RFC2863]
+ (ipfixObservationPointPhysicalInterface). If the implementors of the
+ IPFIX MIB module want to specify the physical entity where Flows are
+ observed, then they SHOULD also implement the ENTITY MIB and/or the
+ IF MIB module. The implementation of the ENTITY MIB and/or IF MIB
+ module is OPTIONAL. If one of them is not implemented, then all
+ values of the respective column ipfixObservationPointPhysicalEntity
+ or ipfixObservationPointPhysicalInterface in the Observation Point
+ table are zero and the values of the
+ ipfixObservationPointPhysicalEntityDirection columns are unknown(0),
+ if none of them are defined.
+
+7.2. MIB Modules Required for IMPORTS
+
+ The IPFIX MIB module requires the modules SNMPv2-SMI [RFC2578],
+ SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580]. Further on, it
+ imports the textual conventions InetAddressType and InetAddress from
+ the INET ADDRESS MIB module [RFC4001].
+
+ The IPFIX SELECTOR MIB module also requires the modules SNMPv2-SMI
+ [RFC2578], SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580].
+
+8. MIB Definitions
+
+ This section contains the definitions of the IPFIX-MIB module and the
+ IPFIX-SELECTOR-MIB module. There are different mandatory groups
+ defined for Collector and Exporter implementations. The statistical
+ objects are made OPTIONAL.
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 18]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+8.1. IPFIX MIB Definition
+
+ IPFIX-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, mib-2, Unsigned32, Counter64,
+ Gauge32
+ FROM SNMPv2-SMI -- RFC2578
+ TimeStamp, DateAndTime
+ FROM SNMPv2-TC -- RFC2579
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF -- RFC2580
+ InterfaceIndexOrZero
+ FROM IF-MIB -- RFC2863
+ InetAddressType, InetAddress, InetPortNumber
+ FROM INET-ADDRESS-MIB -- RFC4001
+ PhysicalIndexOrZero
+ FROM ENTITY-MIB; -- RFC4133
+
+ ipfixMIB MODULE-IDENTITY
+ LAST-UPDATED "201004190000Z" -- 19 April 2010
+ ORGANIZATION "IETF IPFIX Working Group"
+ CONTACT-INFO
+ "WG charter:
+ http://www.ietf.org/html.charters/ipfix-charter.html
+
+ Mailing Lists:
+ General Discussion: ipfix@ietf.org
+ To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
+ Archive:
+ http://www1.ietf.org/mail-archive/web/ipfix/current/index.html
+
+ Editor:
+ Thomas Dietz
+ NEC Europe Ltd.
+ NEC Laboratories Europe
+ Network Research Division
+ Kurfuersten-Anlage 36
+ 69115 Heidelberg
+ Germany
+ Phone: +49 6221 4342-128
+ Email: Thomas.Dietz@nw.neclab.eu
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 19]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ Atsushi Kobayashi
+ NTT Information Sharing Platform Laboratories
+ 3-9-11 Midori-cho
+ Musashino-shi
+ 180-8585
+ Japan
+ Phone: +81-422-59-3978
+ Email: akoba@nttv6.net
+
+ Benoit Claise
+ Cisco Systems, Inc.
+ De Kleetlaan 6a b1
+ Degem 1831
+ Belgium
+ Phone: +32 2 704 5622
+ Email: bclaise@cisco.com
+
+ Gerhard Muenz
+ Technische Universitaet Muenchen
+ Department of Informatics
+ Chair for Network Architectures and Services (I8)
+ Boltzmannstr. 3
+ 85748 Garching
+ Germany
+ Phone: +49 89 289-18008
+ Email: muenz@net.in.tum.de
+ URI: http://www.net.in.tum.de/~muenz"
+ DESCRIPTION
+ "The IPFIX MIB defines managed objects for IP Flow
+ Information eXport. These objects provide information about
+ managed nodes supporting the IPFIX protocol,
+ for Exporters as well as for Collectors.
+
+ Copyright (c) 2010 IETF Trust and the persons identified as
+ authors of the code. All rights reserved.
+
+ Redistribution and use in source and binary forms, with or
+ without modification, is permitted pursuant to, and subject
+ to the license terms contained in, the Simplified BSD
+ License set forth in Section 4.c of the IETF Trust's
+ Legal Provisions Relating to IETF Documents
+ (http://trustee.ietf.org/license-info)."
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 20]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ -- Revision history
+
+ REVISION "201004190000Z" -- 19 April 2010
+ DESCRIPTION
+ "Initial version, published as RFC 5815."
+
+ ::= { mib-2 193 }
+
+
+ --******************************************************************
+ -- Top Level Structure of the MIB
+ --******************************************************************
+
+ ipfixObjects OBJECT IDENTIFIER ::= { ipfixMIB 1 }
+ ipfixConformance OBJECT IDENTIFIER ::= { ipfixMIB 2 }
+
+ ipfixMainObjects OBJECT IDENTIFIER ::= { ipfixObjects 1 }
+ ipfixStatistics OBJECT IDENTIFIER ::= { ipfixObjects 2 }
+
+ --==================================================================
+ -- 1.1: Objects used by all IPFIX implementations
+ --==================================================================
+ --------------------------------------------------------------------
+ -- 1.1.1: Transport Session Table
+ --------------------------------------------------------------------
+ ipfixTransportSessionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixTransportSessionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists the currently established Transport
+ Sessions between an Exporting Process and a Collecting
+ Process."
+ ::= { ipfixMainObjects 1 }
+
+ ipfixTransportSessionEntry OBJECT-TYPE
+ SYNTAX IpfixTransportSessionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixTransportSessionTable."
+ INDEX { ipfixTransportSessionIndex }
+ ::= { ipfixTransportSessionTable 1 }
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 21]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ IpfixTransportSessionEntry ::=
+ SEQUENCE {
+ ipfixTransportSessionIndex Unsigned32,
+ ipfixTransportSessionProtocol Unsigned32,
+ ipfixTransportSessionSourceAddressType InetAddressType,
+ ipfixTransportSessionSourceAddress InetAddress,
+ ipfixTransportSessionDestinationAddressType InetAddressType,
+ ipfixTransportSessionDestinationAddress InetAddress,
+ ipfixTransportSessionSourcePort InetPortNumber,
+ ipfixTransportSessionDestinationPort InetPortNumber,
+ ipfixTransportSessionSctpAssocId Unsigned32,
+ ipfixTransportSessionDeviceMode INTEGER,
+ ipfixTransportSessionTemplateRefreshTimeout Unsigned32,
+ ipfixTransportSessionOptionsTemplateRefreshTimeout Unsigned32,
+ ipfixTransportSessionTemplateRefreshPacket Unsigned32,
+ ipfixTransportSessionOptionsTemplateRefreshPacket Unsigned32,
+ ipfixTransportSessionIpfixVersion Unsigned32,
+ ipfixTransportSessionStatus INTEGER
+ }
+
+ ipfixTransportSessionIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in
+ the ipfixTransportSessionTable. The value is expected to
+ remain constant from a re-initialization of the entity's
+ network management agent to the next re-initialization."
+ ::= { ipfixTransportSessionEntry 1 }
+
+ ipfixTransportSessionProtocol OBJECT-TYPE
+ SYNTAX Unsigned32 (1..255)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transport protocol used for receiving or transmitting
+ IPFIX Messages. Protocol numbers are assigned by IANA. A
+ current list of all assignments is available from
+ <http://www.iana.org/>."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow
+ Information Export (IPFIX) Protocol for the Exchange of IP
+ Traffic Flow Information, Section 10."
+ ::= { ipfixTransportSessionEntry 2 }
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 22]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTransportSessionSourceAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of address used for the source address,
+ as specified in RFC 4001. This object is used with protocols
+ (specified in ipfixTransportSessionProtocol) like TCP (6)
+ and UDP (17) that have the notion of addresses. SCTP (132)
+ should use the ipfixTransportSessionSctpAssocId instead.
+ If SCTP (132) or any other protocol without the notion of
+ addresses is used, the object MUST be set to unknown(0)."
+ ::= { ipfixTransportSessionEntry 3 }
+
+ ipfixTransportSessionSourceAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The source address of the Exporter of the IPFIX Transport
+ Session. This value is interpreted according to the value of
+ ipfixTransportSessionAddressType as specified in RFC 4001.
+ This object is used with protocols (specified in
+ ipfixTransportSessionProtocol) like TCP (6) and UDP (17) that
+ have the notion of addresses. SCTP (132) should use the
+ ipfixTransportSessionSctpAssocId instead. If SCTP (132) or
+ any other protocol without the notion of addresses is used,
+ the object MUST be set to a zero-length string."
+ ::= { ipfixTransportSessionEntry 4 }
+
+ ipfixTransportSessionDestinationAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of address used for the destination address,
+ as specified in RFC 4001. This object is used with protocols
+ (specified in ipfixTransportSessionProtocol) like TCP (6)
+ and UDP (17) that have the notion of addresses. SCTP (132)
+ should use the ipfixTransportSessionSctpAssocId instead.
+ If SCTP (132) or any other protocol without the notion of
+ addresses is used, the object MUST be set to unknown(0)."
+ ::= { ipfixTransportSessionEntry 5 }
+
+ ipfixTransportSessionDestinationAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Dietz, et al. Standards Track [Page 23]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The destination address of the Collector of the IPFIX
+ Transport Session. This value is interpreted according to
+ the value of ipfixTransportSessionAddressType, as specified
+ in RFC 4001. This object is used with protocols
+ (specified in ipfixTransportSessionProtocol) like TCP (6)
+ and UDP (17) that have the notion of addresses. SCTP (132)
+ should use the ipfixTransportSessionSctpAssocId instead.
+ If SCTP (132) or any other protocol without the notion of
+ addresses is used, the object MUST be set to a zero-length
+ string"
+ ::= { ipfixTransportSessionEntry 6 }
+
+ ipfixTransportSessionSourcePort OBJECT-TYPE
+ SYNTAX InetPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transport protocol port number of the Exporter.
+ This object is used with protocols (specified in
+ ipfixTransportSessionProtocol) like TCP (6)
+ and UDP (17) that have the notion of ports. SCTP (132)
+ should copy the value of sctpAssocLocalPort if the
+ Transport Session is in collecting mode or
+ sctpAssocRemPort if the Transport Session is in
+ exporting mode. The association is referenced
+ by the ipfixTransportSessionSctpAssocId.
+ If any other protocol without the notion of
+ ports is used, the object MUST be set to zero."
+ ::= { ipfixTransportSessionEntry 7 }
+
+ ipfixTransportSessionDestinationPort OBJECT-TYPE
+ SYNTAX InetPortNumber
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The transport protocol port number of the Collector. The
+ default value is 4739 for all currently defined transport
+ protocol types. This object is used with protocols
+ (specified in ipfixTransportSessionProtocol) like TCP (6)
+ and UDP (17) that have the notion of ports. SCTP (132)
+ should copy the value of sctpAssocRemPort if the
+ Transport Session is in collecting mode or
+ sctpAssocLocalPort if the Transport Session is in
+ exporting mode. The association is referenced
+ by the ipfixTransportSessionSctpAssocId.
+ If any other protocol without the notion of
+ ports is used, the object MUST be set to zero."
+
+
+
+Dietz, et al. Standards Track [Page 24]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ::= { ipfixTransportSessionEntry 8 }
+
+ ipfixTransportSessionSctpAssocId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The association id used for the SCTP session between the
+ Exporter and the Collector of the IPFIX Transport Session.
+ It is equal to the sctpAssocId entry in the sctpAssocTable
+ defined in the SCTP MIB. This object is only valid if
+ ipfixTransportSessionProtocol has the value 132 (SCTP). In
+ all other cases, the value MUST be zero."
+ REFERENCE
+ "RFC 3873, Stream Control Transmission Protocol (SCTP)
+ Management Information Base (MIB)."
+ ::= { ipfixTransportSessionEntry 9 }
+
+ ipfixTransportSessionDeviceMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ exporting(1),
+ collecting(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The mode of operation of the device for the given Transport
+ Session. This object can have the following values:
+
+ exporting(1)
+ This value MUST be used if the Transport Session is
+ used for exporting Records to other IPFIX Devices,
+ i.e., this device acts as Exporter.
+
+ collecting(2)
+ This value MUST be used if the Transport Session is
+ used for collecting Records from other IPFIX Devices,
+ i.e., this device acts as Collector."
+ ::= { ipfixTransportSessionEntry 10 }
+
+ ipfixTransportSessionTemplateRefreshTimeout OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 25]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "On Exporters, this object contains the time in seconds
+ after which IPFIX Templates are resent by the
+ Exporter.
+
+ On Collectors, this object contains the lifetime in seconds
+ after which a Template becomes invalid when it is not
+ received again within this lifetime.
+
+ This object is only valid if ipfixTransportSessionProtocol
+ has the value 17 (UDP). In all other cases, the value MUST
+ be zero."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 10.3.6 and 10.3.7."
+ ::= { ipfixTransportSessionEntry 11 }
+
+ ipfixTransportSessionOptionsTemplateRefreshTimeout OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On Exporters, this object contains the time in seconds
+ after which IPFIX Options Templates are resent by the
+ Exporter.
+
+ On Collectors, this object contains the lifetime in seconds
+ after which an Options Template becomes invalid when it is
+ not received again within this lifetime.
+
+ This object is only valid if ipfixTransportSessionProtocol
+ has the value 17 (UDP). In all other cases the value MUST
+ be zero."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 10.3.6 and 10.3.7."
+ ::= { ipfixTransportSessionEntry 12 }
+
+ ipfixTransportSessionTemplateRefreshPacket OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "packets"
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+
+Dietz, et al. Standards Track [Page 26]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "On Exporters, this object contains the number of exported
+ IPFIX Messages after which IPFIX Templates are resent
+ by the Exporter.
+
+ On Collectors, this object contains the lifetime in number
+ of exported IPFIX Messages after which a Template becomes
+ invalid when it is not received again within this lifetime.
+
+ This object is only valid if ipfixTransportSessionProtocol
+ has the value 17 (UDP). In all other cases the value MUST
+ be zero."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 10.3.6 and 10.3.7."
+ ::= { ipfixTransportSessionEntry 13 }
+
+ ipfixTransportSessionOptionsTemplateRefreshPacket OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On Exporters, this object contains the number of exported
+ IPFIX Messages after which IPFIX Options Templates are
+ resent by the Exporter.
+
+ On Collectors, this object contains the lifetime in number
+ of exported IPFIX Messages after which an Options Template
+ becomes invalid when it is not received again within this
+ lifetime.
+
+ This object is only valid if ipfixTransportSessionProtocol
+ has the value 17 (UDP). In all other cases the value MUST
+ be zero."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 10.3.6 and 10.3.7."
+ ::= { ipfixTransportSessionEntry 14 }
+
+ ipfixTransportSessionIpfixVersion OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+
+Dietz, et al. Standards Track [Page 27]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "On Exporters the object contains the version number of the
+ IPFIX protocol that the Exporter uses to export its data in
+ this Transport Session.
+
+ On Collectors the object contains the version number of the
+ IPFIX protocol it receives for this Transport Session.
+
+ If IPFIX Messages of different IPFIX protocol versions are
+ transmitted or received in this Transport Session, this
+ object contains the maximum version number."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.1."
+ ::= { ipfixTransportSessionEntry 15 }
+
+ ipfixTransportSessionStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ inactive(1),
+ active(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The status of a Transport Session. This object can have the
+ following values:
+
+ unknown(0)
+ This value MUST be used if the status of the
+ Transport Session cannot be detected by the equipment.
+ This value should be avoided as far as possible.
+
+ inactive(1)
+ This value MUST be used for Transport Sessions that
+ are specified in the system but are not currently active.
+ The value can be used, e.g., for Transport Sessions that
+ are backup (secondary) sessions in a Transport Session
+ group.
+
+ active(2)
+ This value MUST be used for Transport Sessions that are
+ currently active and transmitting or receiving data."
+ ::= { ipfixTransportSessionEntry 16 }
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 28]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ --------------------------------------------------------------------
+ -- 1.1.2: Template Table
+ --------------------------------------------------------------------
+ ipfixTemplateTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixTemplateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists the Templates and Options Templates that
+ are transmitted by the Exporting Process or received by the
+ Collecting Process.
+
+ The table contains the Templates and Options Templates that
+ are received or used for exporting data for a given
+ Transport Session group and Observation Domain.
+
+ Withdrawn or invalidated (Options) Template MUST be removed
+ from this table."
+ ::= { ipfixMainObjects 2 }
+
+ ipfixTemplateEntry OBJECT-TYPE
+ SYNTAX IpfixTemplateEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixTemplateTable."
+ INDEX {
+ ipfixTransportSessionIndex,
+ ipfixTemplateObservationDomainId,
+ ipfixTemplateId
+ }
+ ::= { ipfixTemplateTable 1 }
+
+ IpfixTemplateEntry ::=
+ SEQUENCE {
+ ipfixTemplateObservationDomainId Unsigned32,
+ ipfixTemplateId Unsigned32,
+ ipfixTemplateSetId Unsigned32,
+ ipfixTemplateAccessTime DateAndTime
+ }
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 29]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateObservationDomainId OBJECT-TYPE
+ SYNTAX Unsigned32 (0..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The Id of the Observation Domain for which this Template
+ is defined. This value is used when sending IPFIX Messages.
+
+ The special value of 0 indicates that the Data Records
+ exported with this (Option Template) cannot be applied to a
+ single Observation Domain."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.1."
+ ::= { ipfixTemplateEntry 1 }
+
+ ipfixTemplateId OBJECT-TYPE
+ SYNTAX Unsigned32 (256..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This number indicates the Template Id in the IPFIX
+ Message. Values from 0 to 255 are not allowed for Template
+ Ids."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.4.1."
+ ::= { ipfixTemplateEntry 2 }
+
+ ipfixTemplateSetId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This number indicates the Set Id of the Template. This
+ object allows to easily retrieve the Template type.
+
+ Currently, there are two values defined. The value 2 is
+ used for Sets containing Template definitions. The value 3
+ is used for Sets containing Options Template definitions."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.3.2."
+ ::= { ipfixTemplateEntry 3 }
+
+
+
+
+Dietz, et al. Standards Track [Page 30]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateAccessTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the Transport Session is in exporting mode
+ (ipfixTransportSessionDeviceMode) the time when this
+ (Options) Template was last sent to the Collector(s).
+
+ In the specific case of UDP as transport protocol, this
+ time is used to know when a retransmission of the
+ (Options) Template is needed.
+
+ If it is in collecting mode, this object contains the
+ time when this (Options) Template was last received from
+ the Exporter. In the specific case of UDP as transport
+ protocol, this time is used to know when this (Options)
+ Template times out and thus is no longer valid."
+ ::= { ipfixTemplateEntry 4 }
+
+ --------------------------------------------------------------------
+ -- 1.1.3: Exported Template Definition Table
+ --------------------------------------------------------------------
+ ipfixTemplateDefinitionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixTemplateDefinitionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "On Exporters, this table lists the (Options) Template fields
+ of which a (Options) Template is defined. It defines the
+ (Options) Template given in the ipfixTemplateId specified in
+ the ipfixTemplateTable.
+
+ On Collectors, this table lists the (Options) Template fields
+ of which a (Options) Template is defined. It defines the
+ (Options) Template given in the ipfixTemplateId specified in
+ the ipfixTemplateTable."
+ ::= { ipfixMainObjects 3 }
+
+ ipfixTemplateDefinitionEntry OBJECT-TYPE
+ SYNTAX IpfixTemplateDefinitionEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixTemplateDefinitionTable."
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 31]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ INDEX {
+ ipfixTransportSessionIndex,
+ ipfixTemplateObservationDomainId,
+ ipfixTemplateId,
+ ipfixTemplateDefinitionIndex
+ }
+ ::= { ipfixTemplateDefinitionTable 1 }
+
+ IpfixTemplateDefinitionEntry ::=
+ SEQUENCE {
+ ipfixTemplateDefinitionIndex Unsigned32,
+ ipfixTemplateDefinitionIeId Unsigned32,
+ ipfixTemplateDefinitionIeLength Unsigned32,
+ ipfixTemplateDefinitionEnterpriseNumber Unsigned32,
+ ipfixTemplateDefinitionFlags BITS
+ }
+
+ ipfixTemplateDefinitionIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The ipfixTemplateDefinitionIndex specifies the order in
+ which the Information Elements are used in the (Options)
+ Template Record.
+
+ Since a Template Record can contain a maximum of 65535
+ Information Elements, the index is limited to this value."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 3.4.1 and 3.4.2."
+ ::= { ipfixTemplateDefinitionEntry 1 }
+
+ ipfixTemplateDefinitionIeId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates the Information Element Id at position
+ ipfixTemplateDefinitionIndex in the (Options) Template
+ ipfixTemplateId. This implicitly specifies the data type
+ of the Information Element. The elements are registered
+ at IANA. A current list of assignments can be found at
+ <http://www.iana.org/assignments/ipfix>"
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 32]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.2.
+
+ RFC 5102, Information Model for IP Flow Information Export."
+ ::= { ipfixTemplateDefinitionEntry 2 }
+
+ ipfixTemplateDefinitionIeLength OBJECT-TYPE
+ SYNTAX Unsigned32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This indicates the length of the Information Element Id at
+ position ipfixTemplateDefinitionIndex in the (Options)
+ Template ipfixTemplateId."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.2.
+
+ RFC 5102, Information Model for IP Flow Information Export."
+ ::= { ipfixTemplateDefinitionEntry 3 }
+
+ ipfixTemplateDefinitionEnterpriseNumber OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "IANA enterprise number of the authority defining the
+ Information Element identifier in this Template Record.
+ Enterprise numbers are assigned by IANA. A current list of
+ all assignments is available from
+ <http://www.iana.org/assignments/enterprise-numbers/>.
+
+ This object must be zero(0) for all standard Information
+ Elements registered with IANA. A current list of these
+ elements is available from
+ <http://www.iana.org/assignments/ipfix/ipfix.xhtml>."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Section 3.2.
+
+ RFC 5102, Information Model for IP Flow Information Export."
+ ::= { ipfixTemplateDefinitionEntry 4 }
+
+
+
+
+
+Dietz, et al. Standards Track [Page 33]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateDefinitionFlags OBJECT-TYPE
+ SYNTAX BITS {
+ scope(0),
+ flowKey(1)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This bitmask indicates special attributes for the
+ Information Element:
+
+ scope(0)
+ This Information Element is used for scope.
+
+ flowKey(1)
+ This Information Element is a Flow Key.
+
+ Thus, we get the following values for an Information Element:
+
+ If neither bit scope(0) nor bit flowKey(1) are set
+ The Information Element is neither used for scoping nor
+ as Flow Key.
+ If only bit scope(0) is set
+ The Information Element is used for scoping.
+ If only bit flowKey(1) is set
+ The Information Element is used as Flow Key.
+
+ Both bit scope(0) and flowKey(1) MUST NOT be set at the same
+ time. This combination is not allowed."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information
+ Export (IPFIX) Protocol for the Exchange of IP Traffic Flow
+ Information, Sections 2 and 3.4.2.1.
+
+ RFC 5102, Information Model for IP Flow Information Export."
+ ::= { ipfixTemplateDefinitionEntry 5 }
+
+ --------------------------------------------------------------------
+ -- 1.1.4: Export Table
+ --------------------------------------------------------------------
+ ipfixExportTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixExportEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists all exports of an IPFIX device.
+
+
+
+
+
+Dietz, et al. Standards Track [Page 34]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ On Exporters, this table contains all exports grouped by
+ Transport Session, Observation Domain Id, Template Id, and
+ Metering Process represented by the
+ ipfixMeteringProcessCacheId. Thanks to the ipfixExportIndex,
+ the exports can group one or more Transport Sessions to
+ achieve a special functionality like failover management,
+ load-balancing, etc. The entries with the same
+ ipfixExportIndex, ipfixObservationDomainId,
+ and ipfixMeteringProcessCacheId define a Transport
+ Session group. If the Exporter does not use Transport
+ Session grouping, then each ipfixExportIndex contains a
+ single ipfixMeteringProcessCacheId and thus a singe
+ Transport Session, and this session MUST have the member
+ type primary(1). Transport Sessions referenced in this
+ table MUST have the ipfixTransportSessionDeviceMode
+ exporting(1).
+
+ On Collectors, this table is not needed."
+ ::= { ipfixMainObjects 4 }
+
+ ipfixExportEntry OBJECT-TYPE
+ SYNTAX IpfixExportEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixExportTable."
+ INDEX {
+ ipfixExportIndex,
+ ipfixMeteringProcessCacheId,
+ ipfixTransportSessionIndex
+ }
+ ::= { ipfixExportTable 1 }
+
+ IpfixExportEntry ::=
+ SEQUENCE {
+ ipfixExportIndex Unsigned32,
+ ipfixExportMemberType INTEGER
+ }
+
+ ipfixExportIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in
+ the ipfixExportTable. The value is expected
+ to remain constant from a re-initialization of the entity's
+ network management agent to the next re-initialization.
+
+
+
+Dietz, et al. Standards Track [Page 35]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ A common ipfixExportIndex between two entries from this
+ table expresses that there is a relationship between the
+ Transport Sessions in ipfixTransportSessionIndex. The type
+ of relationship is expressed by the value of
+ ipfixExportMemberType."
+ ::= { ipfixExportEntry 1 }
+
+ ipfixExportMemberType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ primary(1),
+ secondary(2),
+ parallel(3),
+ loadBalancing(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The type of a member Transport Session in a Transport
+ Session group (identified by the value of ipfixExportIndex,
+ ipfixObservationDomainId, and ipfixMeteringProcessCacheId).
+ The following values are valid:
+
+ unknown(0)
+ This value MUST be used if the status of the group
+ membership cannot be detected by the equipment. This
+ value should be avoided as far as possible.
+
+ primary(1)
+ This value is used for a group member that is used as
+ the primary target of an Exporter. Other group members
+ (with the same ipfixExportIndex and
+ ipfixMeteringProcessCacheId) MUST NOT have the value
+ primary(1) but MUST have the value secondary(2).
+ This value MUST also be specified if the Exporter does
+ not support Transport Session grouping. In this case,
+ the group contains only one Transport Session.
+
+ secondary(2)
+ This value is used for a group member that is used as a
+ secondary target of an Exporter. The Exporter will use
+ one of the targets specified as secondary(2) within the
+ same Transport Session group when the primary target is
+ not reachable.
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 36]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ parallel(3)
+ This value is used for a group member that is used for
+ duplicate exporting, i.e., all group members identified
+ by the ipfixExportIndex are exporting the same Records
+ in parallel. This implies that all group members MUST
+ have the same membertype parallel(3).
+
+ loadBalancing(4)
+ This value is used for a group member that is used
+ as one target for load-balancing. This means that a
+ Record is sent to one of the group members in this
+ group identified by ipfixExportIndex.
+ This implies that all group members MUST have the same
+ membertype loadBalancing(4)."
+ ::= { ipfixExportEntry 2 }
+
+ --------------------------------------------------------------------
+ -- 1.1.5: Metering Process Table
+ --------------------------------------------------------------------
+ ipfixMeteringProcessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixMeteringProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists so-called caches used at the Metering
+ Process to store the metering data of Flows observed at
+ the Observation Points given in the
+ ipfixObservationPointGroupReference. The table lists the
+ timeouts that specify when the cached metering data is
+ expired.
+
+ On Collectors, the table is not needed."
+ ::= { ipfixMainObjects 5 }
+
+ ipfixMeteringProcessEntry OBJECT-TYPE
+ SYNTAX IpfixMeteringProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixMeteringProcessTable."
+ INDEX { ipfixMeteringProcessCacheId }
+ ::= { ipfixMeteringProcessTable 1 }
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 37]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ IpfixMeteringProcessEntry ::=
+ SEQUENCE {
+ ipfixMeteringProcessCacheId Unsigned32,
+ ipfixMeteringProcessObservationPointGroupRef Unsigned32,
+ ipfixMeteringProcessCacheActiveTimeout Unsigned32,
+ ipfixMeteringProcessCacheInactiveTimeout Unsigned32
+ }
+
+ ipfixMeteringProcessCacheId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in the
+ ipfixMeterinProcessTable. The value is expected to remain
+ constant from a re-initialization of the entity's network
+ management agent to the next re-initialization."
+ ::= { ipfixMeteringProcessEntry 1 }
+
+ ipfixMeteringProcessObservationPointGroupRef OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Observation Point Group Id that links this table entry
+ to the ipfixObservationPointTable. The matching
+ ipfixObservationPointGroupId in that table gives the
+ Observation Points used in that cache. If the Observation
+ Points are unknown, the
+ ipfixMeteringProcessObservationPointGroupRef MUST be zero."
+ ::= { ipfixMeteringProcessEntry 2 }
+
+ ipfixMeteringProcessCacheActiveTimeout OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On the Exporter, this object contains the time after which a
+ Flow is expired (and a Data Record for the template is sent)
+ even though packets matching this Flow are still received by
+ the Metering Process. If this value is 0, the Flow is not
+ prematurely expired."
+ REFERENCE
+ "RFC 5470, Architecture for IP Flow Information Export,
+ Section 5.1.1, item 3."
+ ::= { ipfixMeteringProcessEntry 3 }
+
+
+
+
+Dietz, et al. Standards Track [Page 38]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixMeteringProcessCacheInactiveTimeout OBJECT-TYPE
+ SYNTAX Unsigned32
+ UNITS "seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "On the Exporter. this object contains the time after which a
+ Flow is expired (and a Data Record for the template is sent)
+ when no packets matching this Flow are received by the
+ Metering Process for the given number of seconds. If this
+ value is zero, the Flow is expired immediately, i.e., a Data
+ Record is sent for every packet received by the Metering
+ Process."
+ REFERENCE
+ "RFC 5470, Architecture for IP Flow Information Export,
+ Section 5.1.1, item 1"
+ ::= { ipfixMeteringProcessEntry 4 }
+
+ --------------------------------------------------------------------
+ -- 1.1.6: Observation Point Table
+ --------------------------------------------------------------------
+ ipfixObservationPointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixObservationPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists the Observation Points used within an
+ Exporter by the Metering Process. The index
+ ipfixObservationPointGroupId groups Observation Points
+ and is referenced in the Metering Process table.
+
+ On Collectors this table is not needed."
+ ::= { ipfixMainObjects 6 }
+
+ ipfixObservationPointEntry OBJECT-TYPE
+ SYNTAX IpfixObservationPointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixObservationPointTable."
+ INDEX {
+ ipfixObservationPointGroupId,
+ ipfixObservationPointIndex
+ }
+ ::= { ipfixObservationPointTable 1 }
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 39]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ IpfixObservationPointEntry ::=
+ SEQUENCE {
+ ipfixObservationPointGroupId Unsigned32,
+ ipfixObservationPointIndex Unsigned32,
+ ipfixObservationPointObservationDomainId Unsigned32,
+ ipfixObservationPointPhysicalEntity PhysicalIndexOrZero,
+ ipfixObservationPointPhysicalInterface InterfaceIndexOrZero,
+ ipfixObservationPointPhysicalEntityDirection INTEGER
+ }
+
+ ipfixObservationPointGroupId OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in the
+ ipfixObservationPointTable. The value is expected to remain
+ constant from a re-initialization of the entity's network
+ management agent to the next re-initialization.
+
+ This index represents a group of Observation Points.
+
+ The special value of 0 MUST NOT be used within this table
+ but is reserved for the usage in the
+ ipfixMeteringProcessTable. An index of 0 for the
+ ipfixObservationPointGroupReference index in that table
+ indicates that an Observation Point is unknown or
+ unspecified for a Metering Process cache."
+ ::= { ipfixObservationPointEntry 1 }
+
+ ipfixObservationPointIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in the
+ ipfixObservationPointTable. The value is expected to remain
+ constant from a re-initialization of the entity's network
+ management agent to the next re-initialization.
+
+ This index represents a single Observation Point in an
+ Observation Point group."
+ ::= { ipfixObservationPointEntry 2 }
+
+ ipfixObservationPointObservationDomainId OBJECT-TYPE
+ SYNTAX Unsigned32
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Dietz, et al. Standards Track [Page 40]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The Id of the Observation Domain in which this
+ Observation Point is included.
+
+ The special value of 0 indicates that the Observation
+ Points within this group cannot be applied to a single
+ Observation Domain."
+ REFERENCE
+ "RFC 5101, Specification of the IP Flow Information Export
+ (IPFIX) Protocol for the Exchange of IP
+ Traffic Flow Information, Section 3.1."
+ ::= { ipfixObservationPointEntry 3 }
+
+ ipfixObservationPointPhysicalEntity OBJECT-TYPE
+ SYNTAX PhysicalIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the index of a physical entity in
+ the ENTITY MIB. This physical entity is the given
+ Observation Point. If such a physical entity cannot be
+ specified or is not known, then the object is zero."
+ ::= { ipfixObservationPointEntry 4 }
+
+ ipfixObservationPointPhysicalInterface OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the index of a physical interface in
+ the IF MIB. This physical interface is the given
+ Observation Point. If such a physical interface cannot be
+ specified or is not known, then the object is zero.
+
+ This object MAY be used stand alone or in addition to
+ ipfixObservationPointPhysicalEntity. If
+ ipfixObservationPointPhysicalEntity is not zero, this object
+ MUST point to the same physical interface that is
+ referenced in ipfixObservationPointPhysicalEntity.
+ Otherwise, it may reference any interface in the IF MIB."
+ ::= { ipfixObservationPointEntry 5 }
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 41]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixObservationPointPhysicalEntityDirection OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(0),
+ ingress(1),
+ egress(2),
+ both(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The direction of the Flow that is monitored on the given
+ physical entity. The following values are valid:
+
+ unknown(0)
+ This value MUST be used if a direction is not
+ known for the given physical entity.
+
+ ingress(1)
+ This value is used for monitoring incoming Flows on the
+ given physical entity.
+
+ egress(2)
+ This value is used for monitoring outgoing Flows on the
+ given physical entity.
+
+ both(3)
+ This value is used for monitoring incoming and outgoing
+ Flows on the given physical entity."
+ ::= { ipfixObservationPointEntry 6 }
+
+ --------------------------------------------------------------------
+ -- 1.1.7: Selection Process Table
+ --------------------------------------------------------------------
+ ipfixSelectionProcessTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixSelectionProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains Selector Functions connected to a
+ Metering Process by the index ipfixMeteringProcessCacheId.
+ The Selector Functions are grouped into Selection Processes
+ by the ipfixSelectionProcessIndex. The Selector Functions
+ are applied within the Selection Process to the packets
+ observed for the given Metering Process cache in increasing
+ order implied by the ipfixSelectionProcessSelectorIndex.
+ This means Selector Functions with lower
+ ipfixSelectionProcessSelectorIndex are applied first. The
+ remaining packets are accounted for in Flow Records.
+
+
+
+Dietz, et al. Standards Track [Page 42]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ Since IPFIX does not define any Selector Function (except
+ selecting every packet), this is a placeholder for future
+ use and a guideline for implementing enterprise-specific
+ Selector Function objects.
+
+ The following object tree should visualize how the
+ Selector Function objects should be implemented:
+
+ ipfixSelectorFunctions
+ |
+ +- ipfixFuncSelectAll
+ | |
+ | +- ipfixFuncSelectAllAvail (is the function available?)
+ |
+ +- ipfixFuncF2
+ | |
+ | +- ipfixFuncF2Avail (is the function F2 available?)
+ | |
+ | +- ipfixFuncF2Parameters (a table with parameters)
+ ...
+ |
+ +- ipfixFunFn...
+
+ If a Selector Function takes parameters, the MIB should
+ contain a table with an entry for each set of parameters
+ used at the Exporter."
+ ::= { ipfixMainObjects 7 }
+
+ ipfixSelectionProcessEntry OBJECT-TYPE
+ SYNTAX IpfixSelectionProcessEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixSelectionProcessTable."
+ INDEX {
+ ipfixMeteringProcessCacheId,
+ ipfixSelectionProcessIndex,
+ ipfixSelectionProcessSelectorIndex
+ }
+ ::= { ipfixSelectionProcessTable 1 }
+
+ IpfixSelectionProcessEntry ::= SEQUENCE {
+ ipfixSelectionProcessIndex Unsigned32,
+ ipfixSelectionProcessSelectorIndex Unsigned32,
+ ipfixSelectionProcessSelectorFunction OBJECT IDENTIFIER
+ }
+
+
+
+
+
+Dietz, et al. Standards Track [Page 43]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixSelectionProcessIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Locally arbitrary, but unique identifier of an entry in the
+ ipfixSelectionProcessTable. The value is expected to remain
+ constant from a re-initialization of the entity's network
+ management agent to the next re-initialization."
+ ::= { ipfixSelectionProcessEntry 1 }
+
+ ipfixSelectionProcessSelectorIndex OBJECT-TYPE
+ SYNTAX Unsigned32 (1..4294967295)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Index specifying the order in which the referenced
+ ipfixSelctionProcessSelectorFunctions are applied to the
+ observed packet stream within the given Selection Process
+ (identified by the ipfixSelectionProcessIndex). The
+ Selector Functions are applied in increasing order, i.e.,
+ Selector Functions with lower index are applied first."
+ ::= { ipfixSelectionProcessEntry 2 }
+
+ ipfixSelectionProcessSelectorFunction OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The pointer to the Selector Function used at position
+ ipfixSelectionProcessSelectorIndex in the list of Selector
+ Functions for the Metering Process cache specified by the
+ index ipfixMeteringProcessCacheId and for the given
+ Selection Process (identified by the
+ ipfixSelectionProcessIndex).
+
+ This usually points to an object in the IPFIX SELECTOR MIB.
+ If the Selector Function does not take parameters, then it
+ MUST point to the root of the function subtree. If the
+ function takes parameters, then it MUST point to an entry
+ in the parameter table of the Selector Function."
+ ::= { ipfixSelectionProcessEntry 3 }
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 44]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ --------------------------------------------------------------------
+ -- 1.2.1: Transport Session Statistics Table
+ --------------------------------------------------------------------
+ ipfixTransportSessionStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixTransportSessionStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists Transport Sessions statistics between
+ Exporting Processes and Collecting Processes."
+ ::= { ipfixStatistics 1 }
+
+ ipfixTransportSessionStatsEntry OBJECT-TYPE
+ SYNTAX IpfixTransportSessionStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixTransportSessionStatsTable."
+ AUGMENTS { ipfixTransportSessionEntry }
+ ::= { ipfixTransportSessionStatsTable 1 }
+
+ IpfixTransportSessionStatsEntry ::=
+ SEQUENCE {
+ ipfixTransportSessionRate Gauge32,
+ ipfixTransportSessionPackets Counter64,
+ ipfixTransportSessionBytes Counter64,
+ ipfixTransportSessionMessages Counter64,
+ ipfixTransportSessionDiscardedMessages Counter64,
+ ipfixTransportSessionRecords Counter64,
+ ipfixTransportSessionTemplates Counter64,
+ ipfixTransportSessionOptionsTemplates Counter64,
+ ipfixTransportSessionDiscontinuityTime TimeStamp
+ }
+
+ ipfixTransportSessionRate OBJECT-TYPE
+ SYNTAX Gauge32
+ UNITS "bytes/second"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes per second received by the
+ Collector or transmitted by the Exporter. A
+ value of zero (0) means that no packets were sent or
+ received, yet. This object is updated every second."
+ ::= { ipfixTransportSessionStatsEntry 1 }
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 45]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTransportSessionPackets OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received by the Collector
+ or transmitted by the Exporter.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 2 }
+
+ ipfixTransportSessionBytes OBJECT-TYPE
+ SYNTAX Counter64
+ UNITS "bytes"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bytes received by the Collector
+ or transmitted by the Exporter.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 3 }
+
+ ipfixTransportSessionMessages OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of IPFIX Messages received by the
+ Collector or transmitted by the Exporter.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 4 }
+
+ ipfixTransportSessionDiscardedMessages OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 46]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The number of received IPFIX Message that are malformed,
+ cannot be decoded, are received in the wrong order, or are
+ missing according to the sequence number.
+
+ If used at the Exporter, the number of messages that could
+ not be sent due to, e.g., internal buffer overflows, network
+ congestion, or routing issues.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 5 }
+
+ ipfixTransportSessionRecords OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Data Records received by the Collector or
+ transmitted by the Exporter.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 6 }
+
+ ipfixTransportSessionTemplates OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Templates received or transmitted.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 7 }
+
+ ipfixTransportSessionOptionsTemplates OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 47]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The number of Options Templates received or transmitted.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTransportSessionDiscontinuityTime."
+ ::= { ipfixTransportSessionStatsEntry 8 }
+
+ ipfixTransportSessionDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the most recent occasion at which
+ one or more of the Transport Session counters suffered a
+ discontinuity.
+ A value of zero indicates no such discontinuity has
+ occurred since the last re-initialization of the local
+ management subsystem."
+ ::= { ipfixTransportSessionStatsEntry 9 }
+
+ --------------------------------------------------------------------
+ -- 1.2.2: Template Statistics Table
+ --------------------------------------------------------------------
+ ipfixTemplateStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixTemplateStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists statistics objects per Template."
+ ::= { ipfixStatistics 2 }
+
+ ipfixTemplateStatsEntry OBJECT-TYPE
+ SYNTAX IpfixTemplateStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixTemplateStatsTable."
+ AUGMENTS { ipfixTemplateEntry }
+ ::= { ipfixTemplateStatsTable 1 }
+
+ IpfixTemplateStatsEntry ::=
+ SEQUENCE {
+ ipfixTemplateDataRecords Counter64,
+ ipfixTemplateDiscontinuityTime TimeStamp
+ }
+
+
+
+
+
+Dietz, et al. Standards Track [Page 48]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixTemplateDataRecords OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Data Records that are transmitted or received
+ per Template.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system, and at other
+ times as indicated by the value of
+ ipfixTemplateDiscontinuityTime."
+ ::= { ipfixTemplateStatsEntry 1 }
+
+ ipfixTemplateDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the most recent occasion at which
+ the Template counter suffered a discontinuity.
+ A value of zero indicates no such discontinuity has
+ occurred since the last re-initialization of the local
+ management subsystem."
+ ::= { ipfixTemplateStatsEntry 2 }
+
+ --------------------------------------------------------------------
+ -- 1.2.3: Metering Process Statistics Table
+ --------------------------------------------------------------------
+ ipfixMeteringProcessStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixMeteringProcessStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table lists statistic objects that have data per
+ Metering Process cache.
+
+ On Collectors, this table is not needed."
+ ::= { ipfixStatistics 3 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 49]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixMeteringProcessStatsEntry OBJECT-TYPE
+ SYNTAX IpfixMeteringProcessStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixMeteringProcessStatsTable."
+ AUGMENTS { ipfixMeteringProcessEntry }
+ ::= { ipfixMeteringProcessStatsTable 1 }
+
+ IpfixMeteringProcessStatsEntry ::=
+ SEQUENCE {
+ ipfixMeteringProcessCacheActiveFlows Gauge32,
+ ipfixMeteringProcessCacheUnusedCacheEntries Gauge32,
+ ipfixMeteringProcessCacheDataRecords Counter64,
+ ipfixMeteringProcessCacheDiscontinuityTime TimeStamp
+ }
+
+ ipfixMeteringProcessCacheActiveFlows OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Flows currently active at this cache."
+ ::= { ipfixMeteringProcessStatsEntry 1 }
+
+ ipfixMeteringProcessCacheUnusedCacheEntries OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of unused cache entries."
+ ::= { ipfixMeteringProcessStatsEntry 2 }
+
+ ipfixMeteringProcessCacheDataRecords OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of Data Records generated.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixTemplateDiscontinuityTime."
+ ::= { ipfixMeteringProcessStatsEntry 3 }
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 50]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixMeteringProcessCacheDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the most recent occasion at which
+ the Metering Process counter suffered a discontinuity.
+ A value of zero indicates no such discontinuity has
+ occurred since the last re-initialization of the local
+ management subsystem."
+ ::= { ipfixMeteringProcessStatsEntry 4 }
+
+ --------------------------------------------------------------------
+ -- 1.2.4: Selection Process Statistics Table
+ --------------------------------------------------------------------
+ ipfixSelectionProcessStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IpfixSelectionProcessStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains statistics for the Selector Functions
+ connected to Metering Process by the index
+ ipfixMeteringProcessCacheId.
+
+ The indexes MUST match an entry in the
+ ipfixSelectionProcessTable."
+ ::= { ipfixStatistics 4 }
+
+ ipfixSelectionProcessStatsEntry OBJECT-TYPE
+ SYNTAX IpfixSelectionProcessStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Defines an entry in the ipfixSelectionProcessStatsTable."
+ AUGMENTS { ipfixSelectionProcessEntry }
+ ::= { ipfixSelectionProcessStatsTable 1 }
+
+ IpfixSelectionProcessStatsEntry ::= SEQUENCE {
+ ipfixSelectionProcessStatsPacketsObserved Counter64,
+ ipfixSelectionProcessStatsPacketsDropped Counter64,
+ ipfixSelectionProcessStatsDiscontinuityTime TimeStamp
+ }
+
+ ipfixSelectionProcessStatsPacketsObserved OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+
+Dietz, et al. Standards Track [Page 51]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The number of packets observed at the entry point of the
+ function. The entry point may be the Observation Point or
+ the exit point of another Selector Function.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixSelectionProcessStatsDiscontinuityTime."
+ ::= { ipfixSelectionProcessStatsEntry 1 }
+
+ ipfixSelectionProcessStatsPacketsDropped OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets dropped while selecting packets.
+ Discontinuities in the value of this counter can occur at
+ re-initialization of the management system and at other
+ times as indicated by the value of
+ ipfixSelectionProcessStatsDiscontinuityTime."
+ ::= { ipfixSelectionProcessStatsEntry 2 }
+
+ ipfixSelectionProcessStatsDiscontinuityTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the most recent occasion at which
+ one or more of the Selector counters suffered a
+ discontinuity.
+ A value of zero indicates no such discontinuity has
+ occurred since the last re-initialization of the local
+ management subsystem."
+ ::= { ipfixSelectionProcessStatsEntry 3 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 52]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ --==================================================================
+ -- 2: Conformance Information
+ --==================================================================
+ ipfixCompliances OBJECT IDENTIFIER ::= { ipfixConformance 1 }
+ ipfixGroups OBJECT IDENTIFIER ::= { ipfixConformance 2 }
+
+ --------------------------------------------------------------------
+ -- 2.1: Compliance Statements
+ --------------------------------------------------------------------
+ ipfixCollectorCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "An implementation that builds an IPFIX Collector
+ that complies to this module MUST implement the objects
+ defined in the mandatory group ipfixCommonGroup.
+
+ The implementation of all objects in the other groups is
+ optional and depends on the corresponding functionality
+ implemented in the equipment.
+
+ An implementation that is compliant to this MIB module
+ is limited to use only the values TCP (6), UDP (17), and
+ SCTP (132) in the ipfixTransportSessionProtocol object
+ because these are the only protocol currently specified
+ for usage within IPFIX (see RFC 5101)."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ ipfixCommonGroup
+ }
+
+ GROUP ipfixCommonStatsGroup
+ DESCRIPTION
+ "These objects should be implemented if the statistics
+ function is implemented in the equipment."
+ ::= { ipfixCompliances 1 }
+
+ ipfixExporterCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "An implementation that builds an IPFIX Exporter that
+ complies to this module MUST implement the objects defined
+ in the mandatory group ipfixCommonGroup. The implementation
+ of all other objects depends on the implementation of the
+ corresponding functionality in the equipment."
+ MODULE -- this module
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 53]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ MANDATORY-GROUPS {
+ ipfixCommonGroup,
+ ipfixExporterGroup
+ }
+
+ GROUP ipfixCommonStatsGroup
+ DESCRIPTION
+ "These objects should be implemented if the statistics
+ function is implemented in the equipment."
+
+ GROUP ipfixExporterStatsGroup
+ DESCRIPTION
+ "These objects MUST be implemented if statistical functions
+ are implemented on the equipment."
+ ::= { ipfixCompliances 2 }
+
+ --------------------------------------------------------------------
+ -- 2.2: MIB Grouping
+ --------------------------------------------------------------------
+ ipfixCommonGroup OBJECT-GROUP
+ OBJECTS {
+ ipfixTransportSessionProtocol,
+ ipfixTransportSessionSourceAddressType,
+ ipfixTransportSessionSourceAddress,
+ ipfixTransportSessionDestinationAddressType,
+ ipfixTransportSessionDestinationAddress,
+ ipfixTransportSessionSourcePort,
+ ipfixTransportSessionDestinationPort,
+ ipfixTransportSessionSctpAssocId,
+ ipfixTransportSessionDeviceMode,
+ ipfixTransportSessionTemplateRefreshTimeout,
+ ipfixTransportSessionOptionsTemplateRefreshTimeout,
+ ipfixTransportSessionTemplateRefreshPacket,
+ ipfixTransportSessionOptionsTemplateRefreshPacket,
+ ipfixTransportSessionIpfixVersion,
+ ipfixTransportSessionStatus,
+
+ ipfixTemplateSetId,
+ ipfixTemplateAccessTime,
+
+ ipfixTemplateDefinitionIeId,
+ ipfixTemplateDefinitionIeLength,
+ ipfixTemplateDefinitionEnterpriseNumber,
+ ipfixTemplateDefinitionFlags
+ }
+ STATUS current
+
+
+
+
+
+Dietz, et al. Standards Track [Page 54]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ DESCRIPTION
+ "The main IPFIX objects."
+ ::= { ipfixGroups 1 }
+
+ ipfixCommonStatsGroup OBJECT-GROUP
+ OBJECTS {
+ ipfixTransportSessionRate,
+ ipfixTransportSessionPackets,
+ ipfixTransportSessionBytes,
+ ipfixTransportSessionMessages,
+ ipfixTransportSessionDiscardedMessages,
+ ipfixTransportSessionRecords,
+ ipfixTransportSessionTemplates,
+ ipfixTransportSessionOptionsTemplates,
+ ipfixTransportSessionDiscontinuityTime,
+
+ ipfixTemplateDataRecords,
+ ipfixTemplateDiscontinuityTime
+ }
+ STATUS current
+ DESCRIPTION
+ "Common statistical objects."
+ ::= { ipfixGroups 2 }
+
+ ipfixExporterGroup OBJECT-GROUP
+ OBJECTS {
+ ipfixExportMemberType,
+
+ ipfixMeteringProcessObservationPointGroupRef,
+ ipfixMeteringProcessCacheActiveTimeout,
+ ipfixMeteringProcessCacheInactiveTimeout,
+
+ ipfixObservationPointObservationDomainId,
+ ipfixObservationPointPhysicalEntity,
+ ipfixObservationPointPhysicalInterface,
+ ipfixObservationPointPhysicalEntityDirection,
+
+ ipfixSelectionProcessSelectorFunction
+ }
+ STATUS current
+ DESCRIPTION
+ "The main objects for Exporters."
+ ::= { ipfixGroups 3 }
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 55]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ ipfixExporterStatsGroup OBJECT-GROUP
+ OBJECTS {
+ ipfixMeteringProcessCacheActiveFlows,
+ ipfixMeteringProcessCacheUnusedCacheEntries,
+ ipfixMeteringProcessCacheDataRecords,
+ ipfixMeteringProcessCacheDiscontinuityTime,
+
+ ipfixSelectionProcessStatsPacketsObserved,
+ ipfixSelectionProcessStatsPacketsDropped,
+ ipfixSelectionProcessStatsDiscontinuityTime
+ }
+ STATUS current
+ DESCRIPTION
+ "The statistical objects for Exporters."
+ ::= { ipfixGroups 4 }
+
+ END
+
+8.2. IPFIX SELECTOR MIB Definition
+
+
+ IPFIX-SELECTOR-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, mib-2
+ FROM SNMPv2-SMI -- RFC2578
+ TruthValue
+ FROM SNMPv2-TC -- RFC2579
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF; -- RFC2580
+
+ ipfixSelectorMIB MODULE-IDENTITY
+ LAST-UPDATED "201003150000Z" -- 15 March 2010
+ ORGANIZATION "IETF IPFIX Working Group"
+ CONTACT-INFO
+ "WG charter:
+ http://www.ietf.org/html.charters/ipfix-charter.html
+
+ Mailing Lists:
+ General Discussion: ipfix@ietf.org
+ To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
+ Archive:
+ http://www1.ietf.org/mail-archive/web/ipfix/current/index.html
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 56]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ Editor:
+ Thomas Dietz
+ NEC Europe Ltd.
+ NEC Laboratories Europe
+ Network Research Division
+ Kurfuersten-Anlage 36
+ 69115 Heidelberg
+ Germany
+ Phone: +49 6221 4342-128
+ Email: Thomas.Dietz@nw.neclab.eu
+
+ Atsushi Kobayashi
+ NTT Information Sharing Platform Laboratories
+ 3-9-11 Midori-cho
+ Musashino-shi
+ 180-8585
+ Japan
+ Phone: +81-422-59-3978
+ Email: akoba@nttv6.net
+
+ Benoit Claise
+ Cisco Systems, Inc.
+ De Kleetlaan 6a b1
+ Degem 1831
+ Belgium
+ Phone: +32 2 704 5622
+ Email: bclaise@cisco.com
+
+ Gerhard Muenz
+ Technische Universitaet Muenchen
+ Department of Informatics
+ Chair for Network Architectures and Services (I8)
+ Boltzmannstr. 3
+ 85748 Garching
+ Germany
+ Phone: +49 89 289-18008
+ Email: muenz@net.in.tum.de
+ URI: http://www.net.in.tum.de/~muenz"
+ DESCRIPTION
+ "The IPFIX SELECTOR MIB module defines the standard
+ filtering and sampling functions that can be referenced in
+ the ipfixSelectorTable of the IPFIX MIB. The subtree
+ ipfixSelectorFunctions is a placeholder where all standard
+ filtering and sampling functions should be located.
+
+ The IPFIX SELECTOR MIB module is maintained by IANA and can
+ be extended through Expert Review [RFC5226], i.e., review by
+ one of a group of experts designated by an IETF Area
+
+
+
+Dietz, et al. Standards Track [Page 57]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ Director. The group of experts MUST check the requested MIB
+ objects for completeness and accuracy of the description.
+ Requests for MIB objects that duplicate the functionality of
+ existing objects SHOULD be declined. The smallest available
+ OID SHOULD be assigned to a new MIB objects. The
+ specification of new MIB objects SHOULD follow the structure
+ specified in RFC 5815 and MUST be published using a
+ well-established and persistent publication medium. The
+ experts will initially be drawn from the Working Group
+ Chairs and document editors of the IPFIX and PSAMP Working
+ Groups.
+
+ Copyright (c) 2010 IETF Trust and the persons identified as
+ authors of the code. All rights reserved.
+
+ Redistribution and use in source and binary forms, with or
+ without modification, is permitted pursuant to, and subject
+ to the license terms contained in, the Simplified BSD
+ License set forth in Section 4.c of the IETF Trust's
+ Legal Provisions Relating to IETF Documents
+ (http://trustee.ietf.org/license-info)."
+
+ -- Revision history
+
+ REVISION "201003150000Z" -- 15 March 2010
+ DESCRIPTION
+ "Initial version, published as RFC 5815."
+
+ ::= { mib-2 194 }
+
+ --******************************************************************
+ -- Top Level Structure of the MIB
+ --******************************************************************
+
+ ipfixSelectorObjects OBJECT IDENTIFIER
+ ::= { ipfixSelectorMIB 1 }
+ ipfixSelectorConformance OBJECT IDENTIFIER
+ ::= { ipfixSelectorMIB 2 }
+
+ --==================================================================
+ -- 1: Objects used by all IPFIX implementations
+ --==================================================================
+ --------------------------------------------------------------------
+ -- 1.1: Packet Selector Functions for IPFIX
+ --------------------------------------------------------------------
+ ipfixSelectorFunctions OBJECT IDENTIFIER
+ ::= { ipfixSelectorObjects 1 }
+
+
+
+
+Dietz, et al. Standards Track [Page 58]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ --------------------------------------------------------------------
+ -- 1.1.1: Function 1: Selecting All Packets
+ --------------------------------------------------------------------
+ ipfixFuncSelectAll OBJECT IDENTIFIER
+ ::= { ipfixSelectorFunctions 1 }
+
+ ipfixFuncSelectAllAvail OBJECT-TYPE
+ SYNTAX TruthValue
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the availability of the trivial
+ function of selecting all packets. This function is always
+ available."
+ ::= { ipfixFuncSelectAll 1 }
+
+ --==================================================================
+ -- 2: Conformance Information
+ --==================================================================
+ ipfixSelectorCompliances OBJECT IDENTIFIER
+ ::= { ipfixSelectorConformance 1 }
+ ipfixSelectorGroups OBJECT IDENTIFIER
+ ::= { ipfixSelectorConformance 2 }
+
+ --------------------------------------------------------------------
+ -- 2.1: Compliance Statements
+ --------------------------------------------------------------------
+ ipfixSelectorBasicCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "An implementation that builds an IPFIX Exporter that
+ complies to this module MUST implement the objects defined
+ in the mandatory group ipfixBasicGroup. The implementation
+ of all other objects depends on the implementation of the
+ corresponding functionality in the equipment."
+ MODULE -- this module
+ MANDATORY-GROUPS {
+ ipfixSelectorBasicGroup
+ }
+ ::= { ipfixSelectorCompliances 1 }
+
+ --------------------------------------------------------------------
+ -- 2.2: MIB Grouping
+ --------------------------------------------------------------------
+ ipfixSelectorBasicGroup OBJECT-GROUP
+ OBJECTS {
+ ipfixFuncSelectAllAvail
+ }
+
+
+
+Dietz, et al. Standards Track [Page 59]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ STATUS current
+ DESCRIPTION
+ "The main IPFIX objects."
+ ::= { ipfixSelectorGroups 1 }
+
+ END
+
+9. Security Considerations
+
+ There are no management objects defined in this MIB module that have
+ a MAX-ACCESS clause of read-write and/or read-create. So, if these
+ MIB modules are implemented correctly, then there is no risk that an
+ intruder can alter or create any management objects of these MIB
+ modules via direct SNMP SET operations.
+
+ Some of the readable objects in these MIB modules (i.e., objects with
+ a MAX-ACCESS other than not-accessible) may be considered sensitive
+ or vulnerable in some network environments. It is thus important to
+ control even GET and/or NOTIFY access to these objects and possibly
+ to even encrypt the values of these objects when sending them over
+ the network via SNMP. These are the tables and objects and their
+ sensitivity/vulnerability:
+
+ o ipfixTransportSessionTable - contains configuration data that
+ might be sensitive because objects in this table may reveal
+ information about the network infrastructure
+
+ o ipfixExportTable - contains configuration data that might be
+ sensitive because object in this table may reveal information
+ about the network infrastructure as well
+
+ o ipfixMeteringProcessTable - contains configuration data that might
+ be sensitive because objects in this table may reveal information
+ about the IPFIX Device itself
+
+ o ipfixObservationPointTable - contains configuration data that
+ might be sensitive because objects in this table may reveal
+ information about the IPFIX Device itself and the network
+ infrastructure
+
+ o ipfixSelectorFunctions - currently contains no sensitive data but
+ might want to be secured anyway since it may contain sensitive
+ data in a future version
+
+ All other objects and tables contain no data that is considered
+ sensitive.
+
+
+
+
+
+Dietz, et al. Standards Track [Page 60]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+ SNMP versions prior to SNMPv3 did not include adequate security.
+ Even if the network itself is secure (for example by using IPsec),
+ even then, there is no control as to who on the secure network is
+ allowed to access and GET/SET (read/change/create/delete) the objects
+ in these MIB modules.
+
+ It is RECOMMENDED that implementers consider the security features as
+ provided by the SNMPv3 framework (see [RFC3410] Section 8), including
+ full support for the SNMPv3 cryptographic mechanisms (for
+ authentication and privacy).
+
+ Further, deployment of SNMP versions prior to SNMPv3 is NOT
+ RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
+ enable cryptographic security. It is then a customer/operator
+ responsibility to ensure that the SNMP entity giving access to an
+ instance of these MIB modules is properly configured to give access
+ to the objects only to those principals (users) that have legitimate
+ rights to indeed GET or SET (change/create/delete) them.
+
+10. IANA Considerations
+
+ The MIB module in this document uses the following IANA-assigned
+ OBJECT IDENTIFIER values recorded in the SMI Numbers registry:
+
+ Descriptor OBJECT IDENTIFIER value
+ ---------- -----------------------
+ ipfixMIB { mib-2 193 }
+ ipfixSelectorMIB { mib-2 194 }
+
+ Further on, the whole IPFIX SELECTOR MIB module is maintained by
+ IANA. Additions to this MIB module are subject to Expert Review
+ [RFC5226], i.e., review by one of a group of experts designated by an
+ IETF Area Director. The group of experts MUST check the requested
+ MIB objects for completeness and accuracy of the description.
+ Requests for MIB objects that duplicate the functionality of existing
+ objects SHOULD be declined. The smallest available OID SHOULD be
+ assigned to new MIB objects. The specification of new MIB objects
+ SHOULD follow the structure specified in Section 6 and MUST be
+ published using a well-established and persistent publication medium.
+ The experts will initially be drawn from the Working Group Chairs and
+ document editors of the IPFIX and PSAMP Working Groups.
+
+11. Acknowledgments
+
+ This document is a product of the IPFIX Working Group. The authors
+ would like to thank the following persons: Paul Aitken for his
+ detailed review, Dan Romascanu and the MIB doctors, and many more,
+ for the technical reviews and feedback.
+
+
+
+Dietz, et al. Standards Track [Page 61]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+12. References
+
+12.1. Normative References
+
+ [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
+ Requirement Levels", BCP 14, RFC 2119, March 1997.
+
+ [RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
+ Schoenwaelder, Ed., "Structure of Management Information
+ Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
+
+ [RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
+ Schoenwaelder, Ed., "Textual Conventions for SMIv2",
+ STD 58, RFC 2579, April 1999.
+
+ [RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
+ "Conformance Statements for SMIv2", STD 58, RFC 2580,
+ April 1999.
+
+ [RFC4001] Daniele, M., Haberman, B., Routhier, S., and J.
+ Schoenwaelder, "Textual Conventions for Internet Network
+ Addresses", RFC 4001, February 2005.
+
+ [RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
+ MIB", RFC 2863, June 2000.
+
+ [RFC3873] Pastor, J. and M. Belinchon, "Stream Control Transmission
+ Protocol (SCTP) Management Information Base (MIB)",
+ RFC 3873, September 2004.
+
+ [RFC4133] Bierman, A. and K. McCloghrie, "Entity MIB (Version 3)",
+ RFC 4133, August 2005.
+
+ [RFC5101] Claise, B., "Specification of the IP Flow Information
+ Export (IPFIX) Protocol for the Exchange of IP Traffic
+ Flow Information", RFC 5101, January 2008.
+
+ [RFC5102] Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
+ Meyer, "Information Model for IP Flow Information Export",
+ RFC 5102, January 2008.
+
+ [RFC5226] Narten, T. and H. Alvestrand, "Guidelines for Writing an
+ IANA Considerations Section in RFCs", BCP 26, RFC 5226,
+ May 2008.
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 62]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+12.2. Informative References
+
+ [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
+ "Introduction and Applicability Statements for Internet-
+ Standard Management Framework", RFC 3410, December 2002.
+
+ [RFC3917] Quittek, J., Zseby, T., Claise, B., and S. Zander,
+ "Requirements for IP Flow Information Export (IPFIX)",
+ RFC 3917, October 2004.
+
+ [RFC5470] Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek,
+ "Architecture for IP Flow Information Export", RFC 5470,
+ March 2009.
+
+ [RFC5472] Zseby, T., Boschi, E., Brownlee, N., and B. Claise, "IP
+ Flow Information Export (IPFIX) Applicability", RFC 5472,
+ March 2009.
+
+ [RFC5474] Duffield, N., Chiou, D., Claise, B., Greenberg, A.,
+ Grossglauser, M., and J. Rexford, "A Framework for Packet
+ Selection and Reporting", RFC 5474, March 2009.
+
+ [RFC5475] Zseby, T., Molina, M., Duffield, N., Niccolini, S., and F.
+ Raspall, "Sampling and Filtering Techniques for IP Packet
+ Selection", RFC 5475, March 2009.
+
+ [RFC5476] Claise, B., Johnson, A., and J. Quittek, "Packet Sampling
+ (PSAMP) Protocol Specifications", RFC 5476, March 2009.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 63]
+
+RFC 5815 IPFIX MIB April 2010
+
+
+Authors' Addresses
+
+ Thomas Dietz (editor)
+ NEC Europe, Ltd.
+ NEC Laboratories Europe
+ Network Research Division
+ Kurfuersten-Anlage 36
+ Heidelberg 69115
+ DE
+
+ Phone: +49 6221 4342-128
+ EMail: Thomas.Dietz@nw.neclab.eu
+
+
+ Atsushi Kobayashi
+ NTT Information Sharing Platform Laboratories
+ 3-9-11 Midori-cho
+ Musashino-shi, Tokyo 180-8585
+ JA
+
+ Phone: +81-422-59-3978
+ EMail: akoba@nttv6.net
+
+
+ Benoit Claise
+ Cisco Systems, Inc.
+ De Kleetlaan 6a b1
+ Degem 1831
+ BE
+
+ Phone: +32 2 704 5622
+ EMail: bclaise@cisco.com
+
+
+ Gerhard Muenz
+ Technische Universitaet Muenchen
+ Department of Informatics
+ Chair for Network Architectures and Services (I8)
+ Boltzmannstr. 3
+ Garching 85748
+ DE
+
+ Phone: +49 89 289-18008
+ EMail: muenz@net.in.tum.de
+ URI: http://www.net.in.tum.de/~muenz
+
+
+
+
+
+
+Dietz, et al. Standards Track [Page 64]
+