diff options
author | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
---|---|---|
committer | Thomas Voss <mail@thomasvoss.com> | 2024-11-27 20:54:24 +0100 |
commit | 4bfd864f10b68b71482b35c818559068ef8d5797 (patch) | |
tree | e3989f47a7994642eb325063d46e8f08ffa681dc /doc/rfc/rfc7460.txt | |
parent | ea76e11061bda059ae9f9ad130a9895cc85607db (diff) |
doc: Add RFC documents
Diffstat (limited to 'doc/rfc/rfc7460.txt')
-rw-r--r-- | doc/rfc/rfc7460.txt | 3867 |
1 files changed, 3867 insertions, 0 deletions
diff --git a/doc/rfc/rfc7460.txt b/doc/rfc/rfc7460.txt new file mode 100644 index 0000000..9fffd71 --- /dev/null +++ b/doc/rfc/rfc7460.txt @@ -0,0 +1,3867 @@ + + + + + + +Internet Engineering Task Force (IETF) M. Chandramouli +Request for Comments: 7460 B. Claise +Category: Standards Track Cisco Systems, Inc. +ISSN: 2070-1721 B. Schoening + Independent Consultant + J. Quittek + T. Dietz + NEC Europe, Ltd. + March 2015 + + + Monitoring and Control MIB for Power and Energy + +Abstract + + This document defines a subset of the Management Information Base + (MIB) for power and energy monitoring of devices. + +Status of This Memo + + This is an Internet Standards Track document. + + This document is a product of the Internet Engineering Task Force + (IETF). It represents the consensus of the IETF community. It has + received public review and has been approved for publication by the + Internet Engineering Steering Group (IESG). Further information on + Internet Standards is available in Section 2 of RFC 5741. + + Information about the current status of this document, any errata, + and how to provide feedback on it may be obtained at + http://www.rfc-editor.org/info/rfc7460. + +Copyright Notice + + Copyright (c) 2015 IETF Trust and the persons identified as the + document authors. All rights reserved. + + This document is subject to BCP 78 and the IETF Trust's Legal + Provisions Relating to IETF Documents + (http://trustee.ietf.org/license-info) in effect on the date of + publication of this document. Please review these documents + carefully, as they describe your rights and restrictions with respect + to this document. Code Components extracted from this document must + include Simplified BSD License text as described in Section 4.e of + the Trust Legal Provisions and are provided without warranty as + described in the Simplified BSD License. + + + + + +Chandramouli, et al. Standards Track [Page 1] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + Table of Contents + + 1. Introduction ....................................................3 + 1.1. Conventions Used in This Document ..........................3 + 2. The Internet-Standard Management Framework ......................3 + 3. Use Cases .......................................................4 + 4. Terminology .....................................................4 + 5. Architecture Concepts Applied to the MIB Modules ................5 + 5.1. Energy Object Tables .......................................5 + 5.1.1. ENERGY-OBJECT-MIB ...................................5 + 5.1.2. POWER-ATTRIBUTES-MIB ................................7 + 5.1.3. UML Diagram .........................................9 + 5.2. Energy Object Identity ....................................12 + 5.3. Power State ...............................................12 + 5.3.1. Power State Set ....................................13 + 5.4. Energy Object Usage Information ...........................13 + 5.5. Optional Power Usage Attributes ...........................14 + 5.6. Optional Energy Measurement ...............................14 + 5.7. Fault Management ..........................................18 + 6. Discovery ......................................................18 + 7. Link with the Other IETF MIBs ..................................19 + 7.1. Link with the ENTITY-MIB and the ENTITY-SENSOR MIB ........19 + 7.2. Link with the ENTITY-STATE MIB ............................20 + 7.3. Link with the POWER-OVER-ETHERNET MIB .....................21 + 7.4. Link with the UPS MIB .....................................21 + 7.5. Link with the LLDP and LLDP-MED MIBs ......................22 + 8. Structure of the MIB ...........................................23 + 9. MIB Definitions ................................................24 + 9.1. The IANAPowerStateSet-MIB Module ..........................24 + 9.2. The ENERGY-OBJECT-MIB MIB Module ..........................27 + 9.3. The POWER-ATTRIBUTES-MIB MIB Module .......................50 + 10. Security Considerations .......................................63 + 11. IANA Considerations ...........................................64 + 11.1. IANAPowerStateSet-MIB Module .............................65 + 12. References ....................................................65 + 12.1. Normative References .....................................65 + 12.2. Informative References ...................................66 + Acknowledgments ...................................................68 + Contributors ......................................................68 + Authors' Addresses ................................................69 + + + + + + + + + + + +Chandramouli, et al. Standards Track [Page 2] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +1. Introduction + + This document defines a subset of the Management Information Base + (MIB) for use in energy management of devices within or connected to + communication networks. The MIB modules in this document are + designed to provide a model for energy management, which includes + monitoring for Power State and energy consumption of networked + elements. This MIB takes into account the "Energy Management + Framework" [RFC7326], which, in turn, is based on the "Requirements + for Energy Management" [RFC6988]. + + Energy management can be applied to devices in communication + networks. Target devices for this specification include (but are not + limited to) routers, switches, Power over Ethernet (PoE) endpoints, + protocol gateways for building management systems, intelligent + meters, home energy gateways, hosts and servers, sensor proxies, etc. + Target devices and the use cases for Energy Management are discussed + in Energy Management Applicability Statement [EMAN-AS]. + + Where applicable, device monitoring extends to the individual + components of the device and to any attached dependent devices. For + example, a device can contain components that are independent from a + Power State point of view, such as line cards, processor cards, hard + drives. A device can also have dependent attached devices, such as a + switch with PoE endpoints or a power distribution unit with attached + endpoints. + +1.1. Conventions Used in This Document + + The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", + "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and + "OPTIONAL" in this document are to be interpreted as described in RFC + 2119 [RFC2119]. + +2. The Internet-Standard Management Framework + + For a detailed overview of the documents that describe the current + Internet-Standard Management Framework, please refer to section 7 of + RFC 3410 [RFC3410]. + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. MIB objects are generally + accessed through the Simple Network Management Protocol (SNMP). + Objects in the MIB are defined using the mechanisms defined in the + Structure of Management Information (SMI). This memo specifies MIB + modules that are compliant to SMIv2, which is described in STD 58, + RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 + [RFC2580]. + + + +Chandramouli, et al. Standards Track [Page 3] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +3. Use Cases + + Requirements for power and energy monitoring for networking devices + are specified in [RFC6988]. The requirements in [RFC6988] cover + devices typically found in communications networks, such as switches, + routers, and various connected endpoints. For a power monitoring + architecture to be useful, it should also apply to facility meters, + power distribution units, gateway proxies for commercial building + control, home automation devices, and devices that interface with the + utility and/or smart grid. Accordingly, the scope of the MIB modules + in this document are broader than that specified in [RFC6988]. + Several use cases for Energy Management have been identified in the + "Energy Management (EMAN) Applicability Statement" [EMAN-AS]. + +4. Terminology + + Please refer to [RFC7326] for the definitions of the following + terminology used in this document. + + Energy Management + Energy Management System (EnMS) + Energy Monitoring + Energy Control + electrical equipment + non-electrical equipment (mechanical equipment) + device + component + power inlet + power outlet + energy + power + demand + provide energy + receive energy + meter (energy meter) + battery + Power Interface + Nameplate Power + Power Attributes + Power Quality + Power State + Power State Set + + + + + + + + + +Chandramouli, et al. Standards Track [Page 4] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +5. Architecture Concepts Applied to the MIB Modules + + This section describes the concepts specified in the Energy + Management Framework [RFC7326] that pertain to power usage, with + specific information related to the MIB module specified in this + document. This subsection maps concepts developed in the Energy + Management Framework [RFC7326]. + + The Energy Monitoring MIB has two independent MIB modules: ENERGY- + OBJECT-MIB and POWER-ATTRIBUTES-MIB. The first, ENERGY-OBJECT-MIB, + is focused on measurement of power and energy. The second, POWER- + ATTRIBUTES-MIB, is focused on power quality measurements for Energy + Objects. + + Devices and their sub-components can be modeled using the containment + tree of the ENTITY-MIB [RFC6933]. + +5.1. Energy Object Tables + +5.1.1. ENERGY-OBJECT-MIB + + The ENERGY-OBJECT-MIB module consists of five tables. + + The first table is the eoMeterCapabilitiesTable. It indicates the + instrumentation available for each Energy Object. Entries in this + table indicate which other tables from the ENERGY-OBJECT-MIB and + POWER-ATTRIBUTES-MIB are available for each Energy Object. The + eoMeterCapabilitiesTable is indexed by entPhysicalIndex [RFC6933]. + + The second table is the eoPowerTable. It reports the power + consumption of each Energy Object as well as the units, sign, + measurement accuracy, and related objects. The eoPowerTable is + indexed by entPhysicalIndex. + + The third table is the eoPowerStateTable. For each Energy Object, it + reports information and statistics about the supported Power States. + The eoPowerStateTable is indexed by entPhysicalIndex and + eoPowerStateIndex. + + The fourth table is the eoEnergyParametersTable. The entries in this + table configure the parameters of energy and demand measurement + collection. This table is indexed by eoEnergyParametersIndex. + + The fifth table is the eoEnergyTable. The entries in this table + provide a log of the energy and demand information. This table is + indexed by eoEnergyParametersIndex. + + + + + +Chandramouli, et al. Standards Track [Page 5] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + A "smidump-style" tree presentation of the MIB modules contained in + the document is presented. The meaning of the three symbols is a + compressed representation of the object's MAX-ACCESS clause, which + may have the following values: + + "not-accessible" -> "---" + "accessible-for-notify" -> "--n" + "read-only" -> "r-n" + "read-write" -> "rwn" + + eoMeterCapabilitiesTable(1) + | + +---eoMeterCapabilitiesEntry(1)[entPhysicalIndex] + | | + | +---r-n BITS eoMeterCapability + | + + eoPowerTable(2) + | + +---eoPowerEntry(1) [entPhysicalIndex] + | | + | +---r-n Integer32 eoPower(1) + | +-- r-n Unsigned32 eoPowerNamePlate(2) + | +-- r-n UnitMultiplier eoPowerUnitMultiplier(3) + | +-- r-n Integer32 eoPowerAccuracy(4) + | +-- r-n INTEGER eoPowerMeasurementCaliber(5) + | +-- r-n INTEGER eoPowerCurrentType(6) + | +-- r-n TruthValue eoPowerMeasurementLocal(7) + | +-- rwn PowerStateSet eoPowerAdminState(8) + | +-- r-n PowerStateSet eoPowerOperState(9) + | +-- r-n OwnerString eoPowerStateEnterReason(10) + | + | + | + +---eoPowerStateTable(3) + | + | +--eoPowerStateEntry(1) + | | [entPhysicalIndex, eoPowerStateIndex] + | | + | +-- --n PowerStateSet eoPowerStateIndex(1) + | +-- r-n Integer32 eoPowerStateMaxPower(2) + | +-- r-n UnitMultiplier + | eoPowerStatePowerUnitMultiplier(3) + | +-- r-n TimeTicks eoPowerStateTotalTime(4) + | +-- r-n Counter32 eoPowerStateEnterCount(5) + | + +eoEnergyParametersTable(4) + | + + + +Chandramouli, et al. Standards Track [Page 6] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + +---eoEnergyParametersEntry(1) [eoEnergyParametersIndex] + | + | +-- --n PhysicalIndex eoEnergyObjectIndex(1) + | + r-n Integer32 eoEnergyParametersIndex(2) + | +-- rwn TimeInterval eoEnergyParametersIntervalLength(3) + | +-- rwn Unsigned32 eoEnergyParametersIntervalNumber(4) + | +-- rwn INTEGER eoEnergyParametersIntervalMode(5) + | +-- rwn TimeInterval eoEnergyParametersIntervalWindow(6) + | +-- rwn Unsigned32 eoEnergyParametersSampleRate(7) + | +-- rwn StorageType eoEnergyParametersStorageType(8) + | +-- rwn RowStatus eoEnergyParametersStatus(9) + | + +eoEnergyTable(5) + | + +---eoEnergyEntry(1) + | [eoEnergyParametersIndex,eoEnergyCollectionStartTime] + | + | +-- r-n TimeTicks eoEnergyCollectionStartTime(1) + | +-- r-n Unsigned32 eoEnergyConsumed(2) + | +-- r-n Unsigned32 eoEnergyProvided(3) + | +-- r-n Unsigned32 eoEnergyStored(4) + | +-- r-n UnitMultiplier eoEnergyUnitMultiplier(5) + | +-- r-n Integer32 eoEnergyAccuracy(6) + | +-- r-n Unsigned32 eoEnergyMaxConsumed(7) + | +-- r-n Unsigned32 eoEnergyMaxProduced(8) + | +-- r-n TimeTicks eoEnergyDiscontinuityTime(9) + +5.1.2. POWER-ATTRIBUTES-MIB + + The POWER-ATTRIBUTES-MIB module consists of three tables. + + The first table is the eoACPwrAttributesTable. It indicates the + power quality available for each Energy Object. The + eoACPwrAttributesTable is indexed by entPhysicalIndex [RFC6933]. + + The second table is the eoACPwrAttributesDelPhaseTable. The entries + in this table configure the parameters of energy and demand + measurement collection. This table is indexed by + eoEnergyParametersIndex. + + The third table is the eoACPwrAttributesWyePhaseTable. For each + Energy Object, it reports information and statistics about the + supported Power States. The eoPowerStateTable is indexed by + entPhysicalIndex and eoPowerStateIndex. + + + + + + + +Chandramouli, et al. Standards Track [Page 7] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoACPwrAttributesTable(1) + | + +---eoACPwrAttributesEntry(1) [ entPhysicalIndex] + | | + | +---r-n INTEGER eoACPwrAttributesConfiguration(1) + | +-- r-n Integer32 eoACPwrAttributesAvgVoltage(2) + | +-- r-n Unsigned32 eoACPwrAttributesAvgCurrent(3) + | +-- r-n Integer32 eoACPwrAttributesFrequency(4) + | +-- r-n UnitMultiplier + | eoACPwrAttributesPowerUnitMultiplier(5) + | +-- r-n Integer32 eoACPwrAttributesPowerAccuracy(6) + | +-- r-n Integer32 + | eoACPwrAttributesTotalActivePower(7) + | +-- r-n Integer32 + | eoACPwrAttributesTotalReactivePower(8) + | +-- r-n Integer32 + | eoACPwrAttributesTotalApparentPower(9) + | +-- r-n Integer32 + | eoACPwrAttributesTotalPowerFactor(10) + | +-- r-n Integer32 eoACPwrAttributesThdCurrent(11) + | +-- r-n Integer32 eoACPwrAttributesThdVoltage(12) + | + +eoACPwrAttributesDelPhaseTable(2) + | + +-- eoACPwrAttributesDelPhaseEntry(1) + | | [entPhysicalIndex, eoACPwrAttributesDelPhaseIndex] + | | + | +-- r-n Integer32 + | | eoACPwrAttributesDelPhaseIndex(1) + | +-- r-n Integer32 + | | eoACPwrAttributesDelPhaseToNextPhaseVoltage(2) + | +-- r-n Integer32 + | | eoACPwrAttributesDelThdPhaseToNextPhaseVoltage(3) + | | + +eoACPwrAttributesWyePhaseTable(3) + | + +-- eoACPwrAttributesWyePhaseEntry(1) + | | [entPhysicalIndex, eoACPwrAttributesWyePhaseIndex] + | | + | +-- r-n Integer32 + | | eoACPwrAttributesWyePhaseIndex(1) + | +-- r-n Integer32 + | | eoACPwrAttributesWyePhaseToNeutralVoltage(2) + | +-- r-n Integer32 + | | eoACPwrAttributesWyeCurrent(3) + | +-- r-n Integer32 + | | eoACPwrAttributesWyeActivePower(4) + + + + +Chandramouli, et al. Standards Track [Page 8] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + | +-- r-n Integer32 + | | eoACPwrAttributesWyeReactivePower(5) + | +-- r-n Integer32 + | | eoACPwrAttributesWyeApparentPower(6) + | +-- r-n Integer32 + | | eoACPwrAttributesWyePowerFactor(7) + | +-- r-n Integer32 + | | eoACPwrAttributesWyeThdCurrent(9) + | +-- r-n Integer32 + | | eoACPwrAttributesWyeThdPhaseToNeutralVoltage(10) + +5.1.3. UML Diagram + + A Unified Modeling Language (UML) diagram representation of the MIB + objects in the two MIB modules, ENERGY-OBJECT-MIB and POWER- + ATTRIBUTES-MIB, is presented. + + +-----------------------+ + | Meter Capabilities | + | --------------------- | + | eoMeterCapability | + +-----------------------+ + + +-----------------------+ + |---> | Energy Object ID (*) | + | | --------------------- | + | | entPhysicalIndex | + | | entPhysicalClass | + | | entPhysicalName | + | | entPhysicalUUID | + | +-----------------------+ + | + | +---------------------------+ + |---- |_ Power Table | + | | ------------------------- | + | | eoPower | + | | eoPowerNamePlate | + | | eoPowerUnitMultiplier | + | | eoPowerAccuracy | + | | eoPowerMeasurementCaliber | + | | eoPowerCurrentType | + | | eoPowerMeasurementLocal | + | | eoPowerAdminState | + | | eoPowerOperState | + | | eoPowerStateEnterReason | + | +---------------------------+ + + + + + +Chandramouli, et al. Standards Track [Page 9] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + | +---------------------------------+ + |---- |_Energy Object State Statistics | + | |-------------------------------- | + | | eoPowerStateIndex | + | | eoPowerStateMaxPower | + | | eoPowerStatePowerUnitMultiplier | + | | eoPowerStateTotalTime | + | | eoPowerStateEnterCount | + | +---------------------------------+ + | + | +----------------------------------+ + |---- | Energy ParametersTable | + | | -------------------------------- | + | | eoEnergyObjectIndex | + | | eoEnergyParametersIndex | + | | eoEnergyParametersIntervalLength | + | | eoEnergyParametersIntervalNumber | + | | eoEnergyParametersIntervalMode | + | | eoEnergyParametersIntervalWindow | + | | eoEnergyParametersSampleRate | + | | eoEnergyParametersStorageType | + | | eoEnergyParametersStatus | + | +----------------------------------+ + | + | +----------------------------------+ + |---- | Energy Table | + | -------------------------------- | + | eoEnergyCollectionStartTime | + | eoEnergyConsumed | + | eoEnergyProvided | + | eoEnergyStored | + | eoEnergyUnitMultiplier | + | eoEnergyAccuracy | + | eoEnergyMaxConsumed | + | eoEnergyMaxProduced | + | eoDiscontinuityTime | + +----------------------------------+ + + Figure 1: UML Diagram for energyObjectMib + + (*) Compliance with the ENERGY-OBJECT-CONTEXT-MIB + + + + + + + + + + +Chandramouli, et al. Standards Track [Page 10] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + +-----------------------+ + |---> | Energy Object ID (*) | + | | --------------------- | + | | entPhysicalIndex | + | | entPhysicalName | + | | entPhysicalUUID | + | +-----------------------+ + | +--------------------------------------+ + |---- | Power Attributes | + | | ------------------------------------ | + | | eoACPwrAttributesConfiguration | + | | eoACPwrAttributesAvgVoltage | + | | eoACPwrAttributesAvgCurrent | + | | eoACPwrAttributesFrequency | + | | eoACPwrAttributesPowerUnitMultiplier | + | | eoACPwrAttributesPowerAccuracy | + | | eoACPwrAttributesTotalActivePower | + | | eoACPwrAttributesTotalReactivePower | + | | eoACPwrAttributesTotalApparentPower | + | | eoACPwrAttributesTotalPowerFactor | + | | eoACPwrAttributesThdCurrent | + | | eoACPwrAttributesThdVoltage | + | +--------------------------------------+ + | +------------------------------------------------+ + |---- | AC Input DEL Configuration | + | | ---------------------------------------------- | + | | eoACPwrAttributesDelPhaseIndex | + | | eoACPwrAttributesDelPhaseToNextPhaseVoltage | + | | eoACPwrAttributesDelThdPhaseToNextPhaseVoltage | + | +------------------------------------------------+ + | + | +----------------------------------------------+ + |---- | AC Input WYE Configuration | + | -------------------------------------------- | + | eoACPwrAttributesWyePhaseIndex | + | eoACPwrAttributesWyePhaseToNeutralVoltage | + | eoACPwrAttributesWyeCurrent | + | eoACPwrAttributesWyeActivePower | + | eoACPwrAttributesWyeReactivePower | + | eoACPwrAttributesWyeApparentPower | + | eoACPwrAttributesWyePowerFactor | + | eoACPwrAttributesWyeThdCurrent | + | eoACPwrAttributesWyeThdPhaseToNeutralVoltage | + +----------------------------------------------+ + + Figure 2: UML Diagram for the POWER-ATTRIBUTES-MIB + + (*) Compliance with the ENERGY-OBJECT-CONTEXT-MIB + + + +Chandramouli, et al. Standards Track [Page 11] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +5.2. Energy Object Identity + + The Energy Object identity information is specified in the ENERGY- + OBJECT-CONTEXT-MIB module [RFC7461] primary table, i.e., the eoTable. + In this table, Energy Object context such as domain, role + description, and importance are specified. In addition, the ENERGY- + OBJECT-CONTEXT-MIB module specifies the relationship between Energy + Objects. There are several possible relationships between Energy + Objects, such as meteredBy, metering, poweredBy, powering, + aggregatedBy, and aggregating as defined in the IANA-ENERGY-RELATION- + MIB module [RFC7461]. + +5.3. Power State + + An Energy Object may have energy-conservation modes called "Power + States". There may be several intermediate energy-saving modes + between the ON and OFF states of a device. + + Power States, which represent universal states of power management of + an Energy Object, are specified by the eoPowerState MIB object. The + actual Power State is specified by the eoPowerOperState MIB object, + while the eoPowerAdminState MIB object specifies the Power State + requested for the Energy Object. The difference between the values + of eoPowerOperState and eoPowerAdminState indicates that the Energy + Object is busy transitioning from eoPowerAdminState into the + eoPowerOperState, at which point it will update the content of + eoPowerOperState. In addition, the possible reason for a change in + Power State is reported in eoPowerStateEnterReason. Regarding + eoPowerStateEnterReason, management stations and Energy Objects + should support any format of the owner string dictated by the local + policy of the organization. It is suggested that this name contain + at least the reason for the transition change, and one or more of the + following: IP address, management station name, network manager's + name, location, or phone number. + + The MIB objects eoPowerOperState, eoPowerAdminState, and + eoPowerStateEnterReason are contained in the eoPowerTable. + + eoPowerStateTable enumerates the maximum power usage in watts for + every single supported Power State of each Power State Set supported + by the Energy Object. In addition, eoPowerStateTable provides + additional statistics such as eoPowerStateEnterCount, i.e., the + number of times an entity has visited a particular Power State, and + eoPowerStateTotalTime, i.e., the total time spent in a particular + Power State of an Energy Object. + + + + + + +Chandramouli, et al. Standards Track [Page 12] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +5.3.1. Power State Set + + There are several standards and implementations of Power State Sets. + An Energy Object can support one or multiple Power State Set + implementations concurrently. + + There are currently three Power State Sets defined: + + IEEE1621(256) - [IEEE1621] + DMTF(512) - [DMTF] + EMAN(768) - [RFC7326] + + The Power State Sets are listed in [RFC7326] along with each Power + State within the Power Set. The Power State Sets are specified by + the PowerStateSet Textual Convention (TC) as an IANA-maintained MIB + module. The initial version of this MIB module is specified in this + document. + +5.4. Energy Object Usage Information + + For an Energy Object, power usage is reported using eoPower. The + magnitude of measurement is based on the eoPowerUnitMultiplier MIB + variable, based on the UnitMultiplier TC. Power measurement + magnitude should conform to the IEC 62053-21 [IEC.62053-21] and IEC + 62053-22 [IEC.62053-22] definition of unit multiplier for the SI + units of measure (where SI is the International System of Units). + Measured values are represented in SI units obtained by BaseValue * + 10 raised to the power of the unit multiplier. + + For example, if current power usage of an Energy Object is 3, it + could be 3 W, 3 mW, 3 kW, or 3 MW, depending on the value of + eoPowerUnitMultiplier. Note that other measurements throughout the + two MIB modules in this document use the same mechanism, including + eoPowerStatePowerUnitMultiplier, eoEnergyUnitMultiplier, and + oACPwrAttributesPowerUnitMultiplier. + + In addition to knowing the usage and magnitude, it is useful to know + how an eoPower measurement was obtained. A Network Management System + (NMS) can use this to account for the accuracy and nature of the + reading between different implementations. eoPowerMeasurementLocal + describes whether the measurements were made at the device itself or + from a remote source. The eoPowerMeasurementCaliber describes the + method that was used to measure the power and can distinguish actual + or estimated values. There may be devices in the network that may + not be able to measure or report power consumption. For those + devices, the object eoPowerMeasurementCaliber shall report that the + measurement mechanism is "unavailable" and the eoPower measurement + shall be "0". + + + +Chandramouli, et al. Standards Track [Page 13] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + The nameplate power rating of an Energy Object is specified in + eoPowerNameplate MIB object. + +5.5. Optional Power Usage Attributes + + The optional POWER-ATTRIBUTES-MIB module can be implemented to + further describe power attributes usage measurement. The POWER- + ATTRIBUTES-MIB module is aligned with the IEC 61850 7-2 standard to + describe alternating current (AC) measurements. + + The POWER-ATTRIBUTES-MIB module contains a primary table, + eoACPwrAttributesTable, that defines power attributes measurements + for supported entPhysicalIndex entities, as a sparse extension of the + eoPowerTable (with entPhysicalIndex as primary index). This + eoACPwrAttributesTable table contains such information as the + configuration (single phase, DEL 3 phases, WYE 3 phases), frequency, + power accuracy, total active/reactive power/apparent power, amperage, + and voltage. + + In case of three-phase power, an additional table is populated with + power attributes measurements per phase (hence, double indexed by the + entPhysicalIndex and a phase index). This table, describes + attributes specific to either WYE or DEL configurations. + + In a DEL configuration, the eoACPwrAttributesDelPhaseTable describes + the phase-to-phase power attributes measurements, i.e., voltage. In + a DEL configuration, the current is equal in all three phases. + + In a WYE configuration, the eoACPwrAttributesWyePhaseTable describes + the phase-to-neutral power attributes measurements, i.e., voltage, + current, active/reactive/apparent power, and power factor. + +5.6. Optional Energy Measurement + + It is only relevant to measure energy and demand when there are + actual power measurements obtained from measurement hardware. If the + eoPowerMeasurementCaliber MIB object has values of unavailable, + unknown, estimated, or presumed, then the energy and demand values + are not useful. + + Two tables are introduced to characterize energy measurement of an + Energy Object: eoEnergyTable and eoEnergyParametersTable. Both + energy and demand information can be represented via the + eoEnergyTable. Demand information can be represented. The + eoEnergyParametersTable consists of the parameters defining + eoEnergyParametersIndex -- an index for the Energy Object, + eoEnergyObjectIndex -- linked to the entPhysicalIndex of the Energy + Object, the duration of measurement intervals in seconds, + + + +Chandramouli, et al. Standards Track [Page 14] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + (eoEnergyParametersIntervalLength), the number of successive + intervals to be stored in the eoEnergyTable, + (eoEnergyParametersIntervalNumber), the type of measurement technique + (eoEnergyParametersIntervalMode), and a sample rate used to calculate + the average (eoEnergyParametersSampleRate). Judicious choice of the + sampling rate will ensure accurate measurement of energy while not + imposing an excessive polling burden. + + There are three eoEnergyParametersIntervalMode types used for energy + measurement collection: period, sliding, and total. The choices of + the three different modes of collection are based on IEC standard + 61850-7-4 [IEC.61850-7-4]. Note that multiple + eoEnergyParametersIntervalMode types MAY be configured + simultaneously. It is important to note that for a given Energy + Object, multiple modes (periodic, total, sliding window) of energy + measurement collection can be configured with the use of + eoEnergyParametersIndex. However, simultaneous measurement in + multiple modes for a given Energy Object depends on the Energy Object + capability. + + These three eoEnergyParametersIntervalMode types are illustrated by + the following three figures, for which: + + - The horizontal axis represents the current time, with the symbol + <--- L ---> expressing the eoEnergyParametersIntervalLength and + the eoEnergyCollectionStartTime is represented by S1, S2, S3, + S4, eoEnergyParametersIntervalNumber. + + - The vertical axis represents the time interval of sampling and + the value of eoEnergyConsumed can be obtained at the end of the + sampling period. The symbol =========== denotes the duration of + the sampling period. + + | | | =========== | + |============ | | | + | | | | + | |============ | | + | | | | + | <--- L ---> | <--- L ---> | <--- L ---> | + | | | | + S1 S2 S3 S4 + + Figure 3: Period eoEnergyParametersIntervalMode + + + + + + + + +Chandramouli, et al. Standards Track [Page 15] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + A eoEnergyParametersIntervalMode type of 'period' specifies non- + overlapping periodic measurements. Therefore, the next + eoEnergyCollectionStartTime is equal to the previous + eoEnergyCollectionStartTime plus eoEnergyParametersIntervalLength. + S2=S1+L; S3=S2+L, ... + + |============ | + | | + | <--- L ---> | + | | + | |============ | + | | | + | | <--- L ---> | + | | | + | | |============ | + | | | | + | | | <--- L ---> | + | | | | + | | | |============ | + | | | | | + | | | | <--- L ---> | + S1 | | | | + | | | | + | | | | + S2 | | | + | | | + | | | + S3 | | + | | + | | + S4 + + Figure 4: Sliding eoEnergyParametersIntervalMode + + A eoEnergyParametersIntervalMode type of 'sliding' specifies + overlapping periodic measurements. + + | | + |========================= | + | | + | | + | | + | <--- Total length ---> | + | | + S1 + + Figure 5: Total eoEnergyParametersIntervalMode + + + + +Chandramouli, et al. Standards Track [Page 16] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + An eoEnergyParametersIntervalMode type of 'total' specifies a + continuous measurement since the last reset. The value of + eoEnergyParametersIntervalNumber should be (1) one and + eoEnergyParametersIntervalLength is ignored. + + The eoEnergyParametersStatus is used to start and stop energy usage + logging. The status of this variable is "active" when all the + objects in eoEnergyParametersTable are appropriate, which, in turn, + indicates whether or not eoEnergyTable entries exist. Finally, the + eoEnergyParametersStorageType variable indicates the storage type for + this row, i.e., whether the persistence is maintained across a device + reload. + + The eoEnergyTable consists of energy measurements of + eoEnergyConsumed, eoEnergyProvided and eoEnergyStored, unit scale of + measured energy with eoEnergyUnitMultiplier, percentage accuracy with + eoEnergyAccuracy, and the maximum observed energy within a window in + eoEnergyMaxConsumed, eoEnergyMaxProduced, and + eoEnergyDiscontinuityTime. + + Measurements of the total energy consumed by an Energy Object may + suffer from interruptions in the continuous measurement of energy + consumption. In order to indicate such interruptions, the object + eoEnergyDiscontinuityTime is provided for indicating the time of the + last interruption of total energy measurement. + eoEnergyDiscontinuityTime shall indicate the sysUpTime [RFC3418] when + the device was reset. + + The following example illustrates the eoEnergyTable and + eoEnergyParametersTable: + + First, in order to estimate energy, a time interval to sample energy + should be specified, i.e., eoEnergyParametersIntervalLength can be + set to "900 seconds" or 15 minutes and the number of consecutive + intervals over which the maximum energy is calculated + (eoEnergyParametersIntervalNumber) as "10". The sampling rate + internal to the Energy Object for measurement of power usage + (eoEnergyParametersSampleRate) can be "1000 milliseconds", as set by + the Energy Object as a reasonable value. Then, the + eoEnergyParametersStatus is set to active to indicate that the Energy + Object should start monitoring the usage per the eoEnergyTable. + + The indices for the eoEnergyTable are eoEnergyParametersIndex, which + identifies the index for the setting of energy measurement collection + Energy Object, and eoEnergyCollectionStartTime, which denotes the + start time of the energy measurement interval based on sysUpTime + [RFC3418]. The value of eoEnergyComsumed is the measured energy + consumption over the time interval specified + + + +Chandramouli, et al. Standards Track [Page 17] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + (eoEnergyParametersIntervalLength) based on the Energy Object + internal sampling rate (eoEnergyParametersSampleRate). While + choosing the values for the eoEnergyParametersIntervalLength and + eoEnergyParametersSampleRate, it is recommended to take into + consideration both the network element resources adequate to process + and store the sample values and the mechanism used to calculate the + eoEnergyConsumed. The units are derived from eoEnergyUnitMultiplier. + For example, eoEnergyConsumed can be "100" with + eoEnergyUnitMultiplier equal to 0, the measured energy consumption of + the Energy Object is 100 watt-hours. The eoEnergyMaxConsumed is the + maximum energy observed and that can be "150 watt-hours". + + The eoEnergyTable has a buffer to retain a certain number of + intervals, as defined by eoEnergyParametersIntervalNumber. If the + default value of "10" is kept, then the eoEnergyTable contains 10 + energy measurements, including the maximum. + + Here is a brief explanation of how the maximum energy can be + calculated. The first observed energy measurement value is taken to + be the initial maximum. With each subsequent measurement, based on + numerical comparison, maximum energy may be updated. The maximum + value is retained as long as the measurements are taking place. + Based on periodic polling of this table, an NMS could compute the + maximum over a longer period, e.g., a month, 3 months, or a year. + +5.7. Fault Management + + [RFC6988] specifies requirements about Power States such as "the + current Power State", "the time of the last state change", "the total + time spent in each state", "the number of transitions to each state", + etc. Some of these requirements are fulfilled explicitly by MIB + objects such as eoPowerOperState, eoPowerStateTotalTime, and + eoPowerStateEnterCount. Some of the other requirements are met via + the SNMP NOTIFICATION mechanism. eoPowerStateChange SNMP + notification which is generated when the value of oPowerStateIndex, + eoPowerOperState, or eoPowerAdminState have changed. + +6. Discovery + + It is probable that most Energy Objects will require the + implementation of the ENERGY-OBJECT-CONTEXT-MIB [RFC7461] as a + prerequisite for this MIB module. In such a case, the eoPowerTable + of the EMAN-ENERGY-OBJECT-MIB is cross-referenced with the eoTable of + ENERGY-OBJECT-CONTEXT-MIB via entPhysicalIndex. Every Energy Object + MUST implement entPhysicalIndex, entPhysicalClass, entPhysicalName, + and entPhysicalUUID from the ENTITY-MIB [RFC6933]. As the primary + + + + + +Chandramouli, et al. Standards Track [Page 18] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + index for the Energy Object, entPhysicalIndex is used: it + characterizes the Energy Object in the ENERGY-OBJECT-MIB and the + POWER-ATTRIBUTES-MIB MIB modules (this document). + + The NMS must first poll the ENERGY-OBJECT-CONTEXT-MIB MIB module + [RFC7461], if available, in order to discover all the Energy Objects + and the relationships between those Energy Objects. In the ENERGY- + OBJECT-CONTEXT-MIB module tables, the Energy Objects are indexed by + the entPhysicalIndex. + + From there, the NMS must poll the eoPowerStateTable (specified in the + ENERGY-OBJECT-MIB module in this document), which enumerates, amongst + other things, the maximum power usage. As the entries in + eoPowerStateTable table are indexed by the Energy Object + (entPhysicalIndex) and by the Power State Set (eoPowerStateIndex), + the maximum power usage is discovered per Energy Object, and the + power usage per Power State of the Power State Set. In other words, + reading the eoPowerStateTable allows the discovery of each Power + State within every Power State Set supported by the Energy Object. + + The MIB module may be populated with the Energy Object relationship + information, which have its own Energy Object index value + (entPhysicalIndex). However, the Energy Object relationship must be + discovered via the ENERGY-OBJECT-CONTEXT-MIB module. + + Finally, the NMS can monitor the power attributes with the POWER- + ATTRIBUTES-MIB MIB module, which reuses the entPhysicalIndex to index + the Energy Object. + +7. Link with the Other IETF MIBs + +7.1. Link with the ENTITY-MIB and the ENTITY-SENSOR MIB + + [RFC6933] defines the ENTITY-MIB module that lists the physical + entities of a networking device (router, switch, etc.) and those + physical entities indexed by entPhysicalIndex. From an energy- + management standpoint, the physical entities that consume or produce + energy are of interest. + + [RFC3433] defines the ENTITY-SENSOR MIB module that provides a + standardized way of obtaining information (current value of the + sensor, operational status of the sensor, and the data-unit + precision) from sensors embedded in networking devices. Sensors are + associated with each index of the entPhysicalIndex of the ENTITY-MIB + [RFC6933]. While the focus of the Monitoring and Control MIB for + Power and Energy is on measurement of power usage of networking + equipment indexed by the ENTITY-MIB, this MIB supports a customized + + + + +Chandramouli, et al. Standards Track [Page 19] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + power scale for power measurement and different Power States of + networking equipment and the functionality to configure the Power + States. + + The Energy Objects are modeled by the entPhysicalIndex through the + entPhysicalEntity MIB object specified in the eoTable in the ENERGY- + OBJECT-CONTEXT-MIB MIB module [RFC7461]. + + The ENTITY-SENSOR MIB [RFC3433] does not have the ANSI C12.x accuracy + classes required for electricity (e.g., 1%, 2%, and 0.5% accuracy + classes). Indeed, entPhySensorPrecision [RFC3433] represents "The + number of decimal places of precision in fixed-point sensor values + returned by the associated entPhySensorValue object". The ANSI and + IEC standards are used for power measurement and these standards + require that we use an accuracy class, not the scientific-number + precision model specified in RFC3433. The eoPowerAccuracy MIB object + models this accuracy. Note that eoPowerUnitMultipler represents the + scale factor per IEC 62053-21 [IEC.62053-21] and IEC 62053-22 + [IEC.62053-22], which is a more logical representation for power + measurements (compared to entPhySensorScale), with the mantissa and + the exponent values X * 10 ^ Y. + + Power measurements specifying the qualifier 'UNITS' for each measured + value in watts are used in the LLDP-EXT-MED-MIB, Power Ethernet + [RFC3621], and UPS [RFC1628] MIBs. The same 'UNITS' qualifier is + used for the power measurement values. + + One cannot assume that the ENTITY-MIB and ENTITY-SENSOR MIBs are + implemented for all Energy Objects that need to be monitored. A + typical example is a converged building gateway, which can monitor + other devices in a building and provides a proxy between SNMP and a + protocol like BACnet. Another example is the home energy controller. + In such cases, the eoPhysicalEntity value contains the zero value, + using the PhysicalIndexOrZero Textual Convention. + + The eoPower is similar to entPhySensorValue [RFC3433] and the + eoPowerUnitMultipler is similar to entPhySensorScale. + +7.2. Link with the ENTITY-STATE MIB + + For each entity in the ENTITY-MIB [RFC6933], the ENTITY-STATE MIB + [RFC4268] specifies the operational states (entStateOper: unknown, + enabled, disabled, testing), the alarm (entStateAlarm: unknown, + underRepair, critical, major, minor, warning, indeterminate), and the + possible values of standby states (entStateStandby: unknown, + hotStandby, coldStandby, providingService). + + + + + +Chandramouli, et al. Standards Track [Page 20] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + From a power-monitoring point of view, in contrast to the entity + operational states of entities, Power States are required, as + proposed in the Monitoring and Control MIB for Power and Energy. + Those Power States can be mapped to the different operational states + in the ENTITY-STATE MIB, if a formal mapping is required. For + example, the entStateStandby "unknown", "hotStandby", and + "coldStandby" states could map to the Power State "unknown", "ready", + "standby", respectively, while the entStateStandby "providingService" + could map to any "low" to "high" Power State. + +7.3. Link with the POWER-OVER-ETHERNET MIB + + The Power-over-Ethernet MIB [RFC3621] provides an energy monitoring + and configuration framework for power over Ethernet devices. RFC + 3621 defines a port group entity on a switch for power monitoring and + management policy and does not use the entPhysicalIndex index. + Indeed, pethMainPseConsumptionPower is indexed by the + pethMainPseGroupIndex, which has no mapping with the + entPhysicalIndex. + + If the Power-over-Ethernet MIB [RFC3621] is supported, the Energy + Object eoethPortIndex and eoethPortGrpIndex contain the + pethPsePortIndex and pethPsePortGroupIndex, respectively. However, + one cannot assume that the Power-over-Ethernet MIB is implemented for + most or all Energy Objects. In such cases, the eoethPortIndex and + eoethPortGrpIndex values contain the zero value, via the new + PethPsePortIndexOrZero and PethPsePortGroupIndexOrZero TCs. + + In either case, the entPhysicalIndex MIB object is used as the unique + Energy Object index. + + Note that, even though the Power-over-Ethernet MIB [RFC3621] was + created after the ENTITY-SENSOR MIB [RFC3433], it does not reuse the + precision notion from the ENTITY-SENSOR MIB, i.e., the + entPhySensorPrecision MIB object. + +7.4. Link with the UPS MIB + + To protect against unexpected power disruption, data centers and + buildings make use of Uninterruptible Power Supplies (UPS). To + protect critical assets, a UPS can be restricted to a particular + subset or domain of the network. UPS usage typically lasts only for + a finite period of time, until normal power supply is restored. + Planning is required to decide on the capacity of the UPS based on + output power and duration of probable power outage. To properly + provision UPS power in a data center or building, it is important to + + + + + +Chandramouli, et al. Standards Track [Page 21] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + first understand the total demand required to support all the + entities in the site. This demand can be assessed and monitored via + the Monitoring and Control MIB for Power and Energy. + + The UPS MIB [RFC1628] provides information on the state of the UPS + network. Implementation of the UPS MIB is useful at the aggregate + level of a data center or a building. The MIB module contains + several groups of variables: + + - upsIdent: Identifies the UPS entity (name, model, etc.). + + - upsBattery group: Indicates the battery state (upsbatteryStatus, + upsEstimatedMinutesRemaining, etc.) + + - upsInput group: Characterizes the input load to the UPS (number + of input lines, voltage, current, etc.). + + - upsOutput: Characterizes the output from the UPS (number of + output lines, voltage, current, etc.) + + - upsAlarms: Indicates the various alarm events. + + The measurement of power in the UPS MIB is in volts, amperes, and + watts. The units of power measurement are root mean square (RMS) + volts and RMS amperes. They are not based on the + EntitySensorDataScale and EntitySensorDataPrecision of ENTITY-SENSOR- + MIB. + + Both the Monitoring and Control MIB for Power and Energy and the UPS + MIB may be implemented on the same UPS SNMP agent, without conflict. + In this case, the UPS device itself is the Energy Object and any of + the UPS meters or submeters are the Energy Objects with a possible + relationship as defined in [RFC7326]. + +7.5. Link with the LLDP and LLDP-MED MIBs + + The Link Layer Discovery Protocol (LLDP) is a Data Link Layer + protocol used by network devices to advertise their identities, + capabilities, and interconnections on a LAN network. + + The Media Endpoint Discovery is an enhancement of LLDP, known as + LLDP-MED. The LLDP-MED enhancements specifically address voice + applications. LLDP-MED covers six basic areas: capability discovery, + LAN speed and duplex discovery, network policy discovery, location + identification discovery, inventory discovery, and power discovery. + + + + + + +Chandramouli, et al. Standards Track [Page 22] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + Of particular interest to the current MIB module is the power + discovery, which allows the endpoint device (such as a PoE phone) to + convey power requirements to the switch. In power discovery, + LLDP-MED has four Type-Length-Values (TLVs): power type, power + source, power priority, and power value. Respectively, those TLVs + provide information related to the type of power (power sourcing + entity versus powered device), how the device is powered (from the + line, from a backup source, from external power source, etc.), the + power priority (how important is it that this device has power?), and + how much power the device needs. + + The power priority specified in the LLDP-MED MIB [LLDP-MED-MIB] + actually comes from the Power-over-Ethernet MIB [RFC3621]. If the + Power-over-Ethernet MIB [RFC3621] is supported, the exact value from + the pethPsePortPowerPriority [RFC3621] is copied over into the + lldpXMedRemXPoEPDPowerPriority [LLDP-MED-MIB]; otherwise, the value + in lldpXMedRemXPoEPDPowerPriority is "unknown". From the Monitoring + and Control MIB for Power and Energy, it is possible to identify the + pethPsePortPowerPriority [RFC3621], via the eoethPortIndex and + eoethPortGrpIndex. + + The lldpXMedLocXPoEPDPowerSource [LLDP-MED-MIB] is similar to + eoPowerMeasurementLocal in indicating if the power for an attached + device is local or from a remote device. If the LLDP-MED MIB is + supported, the following mapping can be applied to the + eoPowerMeasurementLocal: lldpXMedLocXPoEPDPowerSource fromPSE(2) and + local(3) can be mapped to false and true, respectively. + +8. Structure of the MIB + + The primary MIB object in the energyObjectMib MIB module is the + energyObjectMibObjects root. The eoPowerTable table of + energyObjectMibObjects describes the power measurement attributes of + an Energy Object entity. The identity of a device in terms of + uniquely identification of the Energy Object and its relationship to + other entities in the network are addressed in [RFC7461]. + + Logically, this MIB module is a sparse extension of the ENERGY- + OBJECT-CONTEXT-MIB module [RFC7461]. Thus, the following + requirements that are applied to [RFC7461] are also applicable. As a + requirement for this MIB module, [RFC7461] SHOULD be implemented and + as Module Compliance of ENTITY-MIB V4 [RFC6933] with respect to + entity4CRCompliance MUST be supported, which requires four MIB + objects: entPhysicalIndex, entPhysicalClass, entPhysicalName, and + entPhysicalUUID MUST be implemented. + + + + + + +Chandramouli, et al. Standards Track [Page 23] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + The eoMeterCapabilitiesTable is useful to enable applications to + determine the capabilities supported by the local management agent. + This table indicates the energy-monitoring MIB groups that are + supported by the local management system. By reading the value of + this object, it is possible for applications to know which tables + contain the information and are usable without walking through the + table and querying every element that involves a trial-and-error + process. + + The power measurement of an Energy Object contains information + describing its power usage (eoPower) and its current Power State + (eoPowerOperState). In addition to power usage, additional + information describing the units of measurement (eoPowerAccuracy, + eoPowerUnitMultiplier), how power usage measurement was obtained + (eoPowerMeasurementCaliber), the source of power measurement + (eoPowerMeasurementLocal), and the type of power (eoPowerCurrentType) + are described. + + An Energy Object may contain an optional eoEnergyTable to describe + energy measurement information over time. + + An Energy Object may contain an optional eoACPwrAttributesTable table + (specified in the POWER-ATTRIBUTES-MIB module) that describes the + electrical characteristics associated with the current Power State + and usage. + + An Energy Object may also contain optional battery information + associated with this entity. + +9. MIB Definitions + +9.1. The IANAPowerStateSet-MIB Module + + -- ************************************************************ + -- + -- + -- This MIB, maintained by IANA, contains a single Textual + -- Convention: PowerStateSet + -- + -- ************************************************************ + + IANAPowerStateSet-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, mib-2 FROM SNMPv2-SMI + TEXTUAL-CONVENTION FROM SNMPv2-TC; + + ianaPowerStateSet MODULE-IDENTITY + + + +Chandramouli, et al. Standards Track [Page 24] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + LAST-UPDATED "201502090000Z" -- 9 February 2015 + ORGANIZATION "IANA" + CONTACT-INFO " + Internet Assigned Numbers Authority + Postal: ICANN + 12025 Waterfront Drive, Suite 300 + Los Angeles, CA 90094 + United States + Tel: +1-310-301 5800 + EMail: iana@iana.org" + + DESCRIPTION + "Copyright (c) 2015 IETF Trust and the persons identified as + authors of the code. All rights reserved. + + Redistribution and use in source and binary forms, with or + without modification, is permitted pursuant to, and subject + to the license terms contained in, the Simplified BSD License + set forth in Section 4.c of the IETF Trust's Legal Provisions + Relating to IETF Documents + (http://trustee.ietf.org/license-info). + + This MIB module defines the PowerStateSet Textual + Convention, which specifies the Power State Sets and + Power State Set Values an Energy Object supports. + + The initial version of this MIB module was published in + RFC 7460; for full legal notices see the RFC itself." + + -- revision history + REVISION "201502090000Z" -- 9 February 2015 + DESCRIPTION + "Initial version of this MIB module, as published as RFC + 7460." + + ::= { mib-2 228 } + + PowerStateSet ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "IANAPowerState is a textual convention that describes + Power State Sets and Power State Set Values an Energy + Object supports. IANA has created a registry of Power + State supported by an Energy Object and IANA shall + administer the list of Power State Sets and Power + States. + + + + + +Chandramouli, et al. Standards Track [Page 25] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + The Textual Convention assumes that Power States in a + Power State Set are limited to 255 distinct values. For + a Power State Set S, the named number with the value S * + 256 is allocated to indicate the Power State Set. For a + Power State X in the Power State Set S, the named number + with the value S * 256 + X + 1 is allocated to represent + the Power State. + + Requests for new values should be made to IANA via email + (iana@iana.org)." + REFERENCE + "http://www.iana.org/assignments/power-state-sets" + + SYNTAX INTEGER { + other(0), -- indicates other set + unknown(255), -- unknown + + ieee1621(256), -- indicates IEEE1621 set + ieee1621Off(257), + ieee1621Sleep(258), + ieee1621On(259), + + dmtf(512), -- indicates DMTF set + dmtfOn(513), + dmtfSleepLight(514), + dmtfSleepDeep(515), + dmtfOffHard(516), + dmtfOffSoft(517), + dmtfHibernate(518), + dmtfPowerOffSoft(519), + dmtfPowerOffHard(520), + dmtfMasterBusReset(521), + dmtfDiagnosticInterrapt(522), + dmtfOffSoftGraceful(523), + dmtfOffHardGraceful(524), + dmtfMasterBusResetGraceful(525), + dmtfPowerCycleOffSoftGraceful(526), + dmtfPowerCycleHardGraceful(527), + + eman(1024), -- indicates EMAN set + emanMechOff(1025), + emanSoftOff(1026), + emanHibernate(1027), + emanSleep(1028), + emanStandby(1029), + emanReady(1030), + emanLowMinus(1031), + emanLow(1032), + + + +Chandramouli, et al. Standards Track [Page 26] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + emanMediumMinus(1033), + emanMedium(1034), + emanHighMinus(1035), + emanHigh(1036) + } + END + +9.2. The ENERGY-OBJECT-MIB MIB Module + + -- ************************************************************ + -- + -- + -- This MIB is used to monitor power usage of network + -- devices + -- + -- ************************************************************* + + ENERGY-OBJECT-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + NOTIFICATION-TYPE, + mib-2, + Integer32, Counter32, Unsigned32, TimeTicks + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, RowStatus, TimeInterval, + TimeStamp, TruthValue, StorageType + FROM SNMPv2-TC + MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP + FROM SNMPv2-CONF + OwnerString + FROM RMON-MIB + entPhysicalIndex + FROM ENTITY-MIB + PowerStateSet + FROM IANAPowerStateSet-MIB; + + energyObjectMib MODULE-IDENTITY + LAST-UPDATED "201502090000Z" -- 9 February 2015 + ORGANIZATION "IETF EMAN Working Group" + CONTACT-INFO + "WG charter: + http://datatracker.ietf.org/wg/eman/charter/ + + Mailing Lists: + General Discussion: eman@ietf.org + + + + +Chandramouli, et al. Standards Track [Page 27] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + To Subscribe: + https://www.ietf.org/mailman/listinfo/eman + + Archive: + http://www.ietf.org/mail-archive/web/eman + + Editors: + Mouli Chandramouli + Cisco Systems, Inc. + Sarjapur Outer Ring Road + Bangalore 560103 + India + Phone: +91 80 4429 2409 + Email: moulchan@cisco.com + + Brad Schoening + 44 Rivers Edge Drive + Little Silver, NJ 07739 + United States + Email: brad.schoening@verizon.net + + Juergen Quittek + NEC Europe, Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + Heidelberg 69115 + Germany + Phone: +49 6221 4342-115 + Email: quittek@neclab.eu + + Thomas Dietz + NEC Europe, Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + 69115 Heidelberg + Germany + Phone: +49 6221 4342-128 + Email: Thomas.Dietz@nw.neclab.eu + + Benoit Claise + Cisco Systems, Inc. + De Kleetlaan 6a b1 + Degem 1831 + Belgium + Phone: +32 2 704 5622 + Email: bclaise@cisco.com" + + + +Chandramouli, et al. Standards Track [Page 28] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "Copyright (c) 2015 IETF Trust and the persons identified as + authors of the code. All rights reserved. + + Redistribution and use in source and binary forms, with or + without modification, is permitted pursuant to, and subject + to the license terms contained in, the Simplified BSD License + set forth in Section 4.c of the IETF Trust's Legal Provisions + Relating to IETF Documents + (http://trustee.ietf.org/license-info). + + This MIB is used to monitor power and energy in + devices. + + The tables eoMeterCapabilitiesTable and eoPowerTable + are a sparse extension of the eoTable from the + ENERGY-OBJECT-CONTEXT-MIB. As a requirement, + [RFC7461] SHOULD be implemented. + + Module Compliance of ENTITY-MIB v4 with respect to + entity4CRCompliance MUST be supported which requires + implementation of 4 MIB objects: entPhysicalIndex, + entPhysicalClass, entPhysicalName and entPhysicalUUID." + REVISION "201502090000Z" -- 9 February 2015 + DESCRIPTION + "Initial version, published as RFC 7460." + + ::= { mib-2 229 } + + energyObjectMibNotifs OBJECT IDENTIFIER + ::= { energyObjectMib 0 } + + energyObjectMibObjects OBJECT IDENTIFIER + ::= { energyObjectMib 1 } + + energyObjectMibConform OBJECT IDENTIFIER + ::= { energyObjectMib 2 } + + -- Textual Conventions + + UnitMultiplier ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The Unit Multiplier is an integer value that represents + the IEEE 61850 Annex A units multiplier associated with + the integer units used to measure the power or energy. + + + + + +Chandramouli, et al. Standards Track [Page 29] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + For example, when used with eoPowerUnitMultiplier, -3 + represents 10^-3 or milliwatts." + REFERENCE + "The International System of Units (SI), National + Institute of Standards and Technology, Spec. Publ. 330, + August 1991." + SYNTAX INTEGER { + yocto(-24), -- 10^-24 + zepto(-21), -- 10^-21 + atto(-18), -- 10^-18 + femto(-15), -- 10^-15 + pico(-12), -- 10^-12 + nano(-9), -- 10^-9 + micro(-6), -- 10^-6 + milli(-3), -- 10^-3 + units(0), -- 10^0 + kilo(3), -- 10^3 + mega(6), -- 10^6 + giga(9), -- 10^9 + tera(12), -- 10^12 + peta(15), -- 10^15 + exa(18), -- 10^18 + zetta(21), -- 10^21 + yotta(24) -- 10^24 + } + + -- Objects + + eoMeterCapabilitiesTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoMeterCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table is useful for helping applications determine + the monitoring capabilities supported by the local + management agents. It is possible for applications to + know which tables are usable without going through a + trial-and-error process." + ::= { energyObjectMibObjects 1 } + + eoMeterCapabilitiesEntry OBJECT-TYPE + SYNTAX EoMeterCapabilitiesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describes the metering capability of an Energy + Object." + INDEX { entPhysicalIndex } + + + +Chandramouli, et al. Standards Track [Page 30] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + ::= { eoMeterCapabilitiesTable 1 } + + EoMeterCapabilitiesEntry ::= SEQUENCE { + eoMeterCapability BITS + } + + eoMeterCapability OBJECT-TYPE + SYNTAX BITS { + none(0), + powermetering(1), -- power measurement + energymetering(2), -- energy measurement + powerattributes(3) -- power attributes + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An indication of the energy-monitoring capabilities + supported by this agent. This object use a BITS syntax + and indicates the MIB groups supported by the probe. By + reading the value of this object, it is possible to + determine the MIB tables supported." + ::= { eoMeterCapabilitiesEntry 1 } + + eoPowerTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table lists Energy Objects." + ::= { energyObjectMibObjects 2 } + + eoPowerEntry OBJECT-TYPE + SYNTAX EoPowerEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describes the power usage of an Energy Object." + INDEX { entPhysicalIndex } + ::= { eoPowerTable 1 } + + EoPowerEntry ::= SEQUENCE { + eoPower Integer32, + eoPowerNameplate Unsigned32, + eoPowerUnitMultiplier UnitMultiplier, + eoPowerAccuracy Integer32, + eoPowerMeasurementCaliber INTEGER, + eoPowerCurrentType INTEGER, + eoPowerMeasurementLocal TruthValue, + + + +Chandramouli, et al. Standards Track [Page 31] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoPowerAdminState PowerStateSet, + eoPowerOperState PowerStateSet, + eoPowerStateEnterReason OwnerString + } + + eoPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the power measured for the Energy + Object. For alternating current, this value is obtained + as an average over fixed number of AC cycles. This value + is specified in SI units of watts with the magnitude of + watts (milliwatts, kilowatts, etc.) indicated separately + in eoPowerUnitMultiplier. The accuracy of the measurement + is specified in eoPowerAccuracy. The direction of power + flow is indicated by the sign on eoPower. If the Energy + Object is consuming power, the eoPower value will be + positive. If the Energy Object is producing power, the + eoPower value will be negative. + + The eoPower MUST be less than or equal to the maximum + power that can be consumed at the Power State specified + by eoPowerState. + + The eoPowerMeasurementCaliber object specifies how the + usage value reported by eoPower was obtained. The eoPower + value must report 0 if the eoPowerMeasurementCaliber is + 'unavailable'. For devices that cannot measure or + report power, this option can be used." + ::= { eoPowerEntry 1 } + + eoPowerNameplate OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the rated maximum consumption for + the fully populated Energy Object. The nameplate power + requirements are the maximum power numbers given in SI + watts and, in almost all cases, are well above the + expected operational consumption. Nameplate power is + widely used for power provisioning. This value is + specified in either units of watts or voltage and + current. The units are therefore SI watts or equivalent + + + +Chandramouli, et al. Standards Track [Page 32] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + Volt-Amperes with the magnitude (milliwatts, kilowatts, + etc.) indicated separately in eoPowerUnitMultiplier." + ::= { eoPowerEntry 2 } + + eoPowerUnitMultiplier OBJECT-TYPE + SYNTAX UnitMultiplier + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of watts for the usage value in eoPower + and eoPowerNameplate." + ::= { eoPowerEntry 3 } + + eoPowerAccuracy OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates a percentage value, in hundredths of a + percent, representing the assumed accuracy of the usage + reported by eoPower. For example, the value 1010 means + the reported usage is accurate to +/- 10.1 percent. This + value is zero if the accuracy is unknown or not + applicable based upon the measurement method. + + ANSI and IEC define the following accuracy classes for + power measurement: + IEC 62053-22 60044-1 class 0.1, 0.2, 0.5, 1 3. + ANSI C12.20 class 0.2, 0.5" + ::= { eoPowerEntry 4 } + + eoPowerMeasurementCaliber OBJECT-TYPE + SYNTAX INTEGER { + unavailable(1) , + unknown(2), + actual(3) , + estimated(4), + static(5) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies how the usage value reported by + eoPower was obtained: + + - unavailable(1): Indicates that the usage is not + available. In such a case, the eoPower value must be 0 + for devices that cannot measure or report power this + + + +Chandramouli, et al. Standards Track [Page 33] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + option can be used. + + - unknown(2): Indicates that the way the usage was + determined is unknown. In some cases, entities report + aggregate power on behalf of another device. In such + cases it is not known whether the usage reported is + actual, estimated, or static. + + - actual(3): Indicates that the reported usage was + measured by the entity through some hardware or direct + physical means. The usage data reported is not estimated + or static but is the measured consumption rate. + + - estimated(4): Indicates that the usage was not + determined by physical measurement. The value is a + derivation based upon the device type, state, and/or + current utilization using some algorithm or heuristic. It + is presumed that the entity's state and current + configuration were used to compute the value. + + - static(5): Indicates that the usage was not determined + by physical measurement, algorithm, or derivation. The + usage was reported based upon external tables, + specifications, and/or model information. For example, a + PC Model X draws 200W, while a PC Model Y draws 210W." + ::= { eoPowerEntry 5 } + + eoPowerCurrentType OBJECT-TYPE + SYNTAX INTEGER { + ac(1), + dc(2), + unknown(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates whether the eoPower for the + Energy Object reports alternating current 'ac', direct + current 'dc', or that the current type is unknown." + ::= { eoPowerEntry 6 } + + eoPowerMeasurementLocal OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the source of power measurement + and can be useful when modeling the power usage of + + + +Chandramouli, et al. Standards Track [Page 34] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + attached devices. The power measurement can be performed + by the entity itself or the power measurement of the + entity can be reported by another trusted entity using a + protocol extension. A value of true indicates the + measurement is performed by the entity, whereas false + indicates that the measurement was performed by another + entity." + ::= { eoPowerEntry 7 } + + eoPowerAdminState OBJECT-TYPE + SYNTAX PowerStateSet + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the desired Power State and the + Power State Set for the Energy Object. Note that other(0) + is not a Power State Set and unknown(255) is not a Power + State as such, but simply an indication that the Power + State of the Energy Object is unknown. + Possible values of eoPowerAdminState within the Power + State Set are registered at IANA. + A current list of assignments can be found at + <http://www.iana.org/assignments/power-state-sets>" + ::= { eoPowerEntry 8 } + + eoPowerOperState OBJECT-TYPE + SYNTAX PowerStateSet + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object specifies the current operational Power + State and the Power State Set for the Energy Object. + other(0) is not a Power State Set and unknown(255) is not + a Power State as such, but simply an indication that the + Power State of the Energy Object is unknown. + + Possible values of eoPowerOperState within the Power + State Set are registered at IANA. A current list of + assignments can be found at + <http://www.iana.org/assignments/power-state-sets>" + ::= { eoPowerEntry 9 } + + eoPowerStateEnterReason OBJECT-TYPE + SYNTAX OwnerString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This string object describes the reason for the + + + +Chandramouli, et al. Standards Track [Page 35] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoPowerAdminState transition. Alternatively, this string + may contain with the entity that configured this Energy + Object to this Power State." + DEFVAL { "" } + ::= { eoPowerEntry 10 } + + eoPowerStateTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoPowerStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table enumerates the maximum power usage, in watts, + for every single supported Power State of each Energy + Object. + + This table has cross-reference with the eoPowerTable, + containing rows describing each Power State for the + corresponding Energy Object. For every Energy Object in + the eoPowerTable, there is a corresponding entry in this + table." + ::= { energyObjectMibObjects 3 } + + eoPowerStateEntry OBJECT-TYPE + SYNTAX EoPowerStateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A eoPowerStateEntry extends a corresponding + eoPowerEntry. This entry displays max usage values at + every single possible Power State supported by the Energy + Object. + For example, given the values of a Energy Object + corresponding to a maximum usage of 0 W at the + state emanmechoff, 8 W at state 6 (ready), 11 W at state + emanmediumMinus, and 11 W at state emanhigh: + + State MaxUsage Units + emanmechoff 0 W + emansoftoff 0 W + emanhibernate 0 W + emansleep 0 W + emanstandby 0 W + emanready 8 W + emanlowMinus 8 W + emanlow 11 W + emanmediumMinus 11 W + emanmedium 11 W + emanhighMinus 11 W + + + +Chandramouli, et al. Standards Track [Page 36] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + emnanhigh 11 W + + Furthermore, this table also includes the total time in + each Power State, along with the number of times a + particular Power State was entered." + + INDEX { entPhysicalIndex, eoPowerStateIndex } + ::= { eoPowerStateTable 1 } + + EoPowerStateEntry ::= SEQUENCE { + eoPowerStateIndex PowerStateSet, + eoPowerStateMaxPower Integer32, + eoPowerStatePowerUnitMultiplier UnitMultiplier, + eoPowerStateTotalTime TimeTicks, + eoPowerStateEnterCount Counter32 + } + + eoPowerStateIndex OBJECT-TYPE + SYNTAX PowerStateSet + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the index of the Power State of + the Energy Object within a Power State Set. The semantics + of the specific Power State can be obtained from the + Power State Set definition." + ::= { eoPowerStateEntry 1 } + + eoPowerStateMaxPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the maximum power for the Energy + Object at the particular Power State. This value is + specified in SI units of watts with the magnitude of the + units (milliwatts, kilowatts, etc.) indicated separately + in eoPowerStatePowerUnitMultiplier. If the maximum power + is not known for a certain Power State, then the value is + encoded as 0xFFFFFFFF. + + For Power States not enumerated, the value of + eoPowerStateMaxPower might be interpolated by using the + next highest supported Power State." + ::= { eoPowerStateEntry 2 } + + + + + +Chandramouli, et al. Standards Track [Page 37] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoPowerStatePowerUnitMultiplier OBJECT-TYPE + SYNTAX UnitMultiplier + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of watts for the usage value in + eoPowerStateMaxPower." + ::= { eoPowerStateEntry 3 } + + eoPowerStateTotalTime OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the total time in hundredths + of a second that the Energy Object has been in this power + state since the last reset, as specified in the + sysUpTime." + ::= { eoPowerStateEntry 4 } + + eoPowerStateEnterCount OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates how often the Energy Object has + entered this power state, since the last reset of the + device as specified in the sysUpTime." + ::= { eoPowerStateEntry 5 } + + eoEnergyParametersTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoEnergyParametersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table is used to configure the parameters for + energy measurement collection in the table eoEnergyTable. + This table allows the configuration of different + measurement settings on the same Energy Object. + Implementation of this table only makes sense for Energy + Objects that an eoPowerMeasurementCaliber of actual." + ::= { energyObjectMibObjects 4 } + + eoEnergyParametersEntry OBJECT-TYPE + SYNTAX EoEnergyParametersEntry + MAX-ACCESS not-accessible + STATUS current + + + + +Chandramouli, et al. Standards Track [Page 38] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "An entry controls an energy measurement in + eoEnergyTable." + INDEX { entPhysicalIndex, eoEnergyParametersIndex } + ::= { eoEnergyParametersTable 1 } + + EoEnergyParametersEntry ::= SEQUENCE { + eoEnergyParametersIndex Integer32, + eoEnergyParametersIntervalLength TimeInterval, + eoEnergyParametersIntervalNumber Unsigned32, + eoEnergyParametersIntervalMode INTEGER, + eoEnergyParametersIntervalWindow TimeInterval, + eoEnergyParametersSampleRate Unsigned32, + eoEnergyParametersStorageType StorageType, + eoEnergyParametersStatus RowStatus + } + + eoEnergyParametersIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the index of the Energy Parameters + setting for collection of energy measurements for an + Energy Object. An Energy Object can have multiple + eoEnergyParametersIndex, depending on the capabilities of + the Energy Object" + ::= { eoEnergyParametersEntry 2 } + + eoEnergyParametersIntervalLength OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates the length of time in hundredths + of a second over which to compute the average + eoEnergyConsumed measurement in the eoEnergyTable table. + The computation is based on the Energy Object's internal + sampling rate of power consumed or produced by the Energy + Object. The sampling rate is the rate at which the Energy + Object can read the power usage and may differ based on + device capabilities. The average energy consumption is + then computed over the length of the interval. The + default value of 15 minutes is a common interval used in + industry." + DEFVAL { 90000 } + ::= { eoEnergyParametersEntry 3 } + + + + +Chandramouli, et al. Standards Track [Page 39] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyParametersIntervalNumber OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The number of intervals maintained in the eoEnergyTable. + Each interval is characterized by a specific + eoEnergyCollectionStartTime, used as an index to the + table eoEnergyTable. Whenever the maximum number of + entries is reached, the measurement over the new interval + replaces the oldest measurement. There is one exception + to this rule: when the eoEnergyMaxConsumed and/or + eoEnergyMaxProduced are in (one of) the two oldest + measurement(s), they are left untouched and the next + oldest measurement is replaced." + DEFVAL { 10 } + ::= { eoEnergyParametersEntry 4 } + + eoEnergyParametersIntervalMode OBJECT-TYPE + SYNTAX INTEGER { + period(1), + sliding(2), + total(3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A control object to define the mode of interval + calculation for the computation of the average + eoEnergyConsumed or eoEnergyProvided measurement in the + eoEnergyTable table. + + A mode of period(1) specifies non-overlapping periodic + measurements. + + A mode of sliding(2) specifies overlapping sliding + windows where the interval between the start of one + interval and the next is defined in + eoEnergyParametersIntervalWindow. + + A mode of total(3) specifies non-periodic measurement. + In this mode only one interval is used as this is a + continuous measurement since the last reset. The value of + eoEnergyParametersIntervalNumber should be (1) one and + eoEnergyParametersIntervalLength is ignored." + ::= { eoEnergyParametersEntry 5 } + + + + + +Chandramouli, et al. Standards Track [Page 40] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyParametersIntervalWindow OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The length of the duration window between the starting + time of one sliding window and the next starting time in + hundredths of seconds, used to compute the average of + eoEnergyConsumed, eoEnergyProvided measurements in the + eoEnergyTable table. This is valid only when the + eoEnergyParametersIntervalMode is sliding(2). The + eoEnergyParametersIntervalWindow value should be a + multiple of eoEnergyParametersSampleRate." + ::= { eoEnergyParametersEntry 6 } + + eoEnergyParametersSampleRate OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Milliseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The sampling rate, in milliseconds, at which the Energy + Object should poll power usage in order to compute the + average eoEnergyConsumed, eoEnergyProvided measurements + in the table eoEnergyTable. The Energy Object should + initially set this sampling rate to a reasonable value, + i.e., a compromise between intervals that will provide + good accuracy by not being too long, but not so short + that they affect the Energy Object performance by + requesting continuous polling. If the sampling rate is + unknown, the value 0 is reported. The sampling rate + should be selected so that + eoEnergyParametersIntervalWindow is a multiple of + eoEnergyParametersSampleRate. The default value is one + second." + DEFVAL { 1000 } + ::= { eoEnergyParametersEntry 7 } + + eoEnergyParametersStorageType OBJECT-TYPE + SYNTAX StorageType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This variable indicates the storage type for this row." + DEFVAL { nonVolatile } + ::= {eoEnergyParametersEntry 8 } + + + + + +Chandramouli, et al. Standards Track [Page 41] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyParametersStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of this row. The eoEnergyParametersStatus is + used to start or stop energy usage logging. An entry + status may not be active(1) unless all objects in the + entry have an appropriate value. If this object is not + equal to active, all associated usage-data logged into + the eoEnergyTable will be deleted. The data can be + destroyed by setting up the eoEnergyParametersStatus to + destroy." + ::= {eoEnergyParametersEntry 9 } + + eoEnergyTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoEnergyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table lists Energy Object energy measurements. + Entries in this table are only created if the + corresponding value of object eoPowerMeasurementCaliber + is active(3), i.e., if the power is actually metered." + ::= { energyObjectMibObjects 5 } + + eoEnergyEntry OBJECT-TYPE + SYNTAX EoEnergyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describing energy measurements." + INDEX { eoEnergyParametersIndex, + eoEnergyCollectionStartTime } + ::= { eoEnergyTable 1 } + + EoEnergyEntry ::= SEQUENCE { + eoEnergyCollectionStartTime TimeTicks, + eoEnergyConsumed Unsigned32, + eoEnergyProvided Unsigned32, + eoEnergyStored Unsigned32, + eoEnergyUnitMultiplier UnitMultiplier, + eoEnergyAccuracy Integer32, + eoEnergyMaxConsumed Unsigned32, + eoEnergyMaxProduced Unsigned32, + eoEnergyDiscontinuityTime TimeStamp + } + + + + +Chandramouli, et al. Standards Track [Page 42] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyCollectionStartTime OBJECT-TYPE + SYNTAX TimeTicks + UNITS "hundredths of a second" + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The time (in hundredths of a second) since the + network management portion of the system was last + re-initialized, as specified in the sysUpTime RFC 3418. + This object specifies the start time of the energy + measurement sample." + REFERENCE + "RFC 3418: Management Information Base (MIB) for the + Simple Network Management Protocol (SNMP)" + ::= { eoEnergyEntry 1 } + + eoEnergyConsumed OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Watt-hours" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the energy consumed in units of + watt-hours for the Energy Object over the defined + interval. This value is specified in the common billing + units of watt-hours with the magnitude of watt-hours + kWh, MWh, etc.) indicated separately in + eoEnergyUnitMultiplier." + ::= { eoEnergyEntry 2 } + + eoEnergyProvided OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Watt-hours" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the energy produced in units of + watt-hours for the Energy Object over the defined + interval. + + This value is specified in the common billing units of + watt-hours with the magnitude of watt-hours (kWh, MWh, + etc.) indicated separately in + eoEnergyUnitMultiplier." + ::= { eoEnergyEntry 3 } + + + + + + +Chandramouli, et al. Standards Track [Page 43] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyStored OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Watt-hours" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the difference of the energy + consumed and energy produced for an Energy Object in + units of watt-hours for the Energy Object over the + defined interval. This value is specified in the common + billing units of watt-hours with the magnitude of + watt-hours (kWh, MWh, etc.) indicated separately in + eoEnergyUnitMultiplier." + ::= { eoEnergyEntry 4 } + + eoEnergyUnitMultiplier OBJECT-TYPE + SYNTAX UnitMultiplier + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the magnitude of watt-hours for the + energy field in eoEnergyConsumed, eoEnergyProvided, + eoEnergyStored, eoEnergyMaxConsumed, and + eoEnergyMaxProduced." + ::= { eoEnergyEntry 5 } + + eoEnergyAccuracy OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates a percentage accuracy, in hundredths + of a percent, of Energy usage reporting. eoEnergyAccuracy + is applicable to all Energy measurements in the + eoEnergyTable. + + For example, 1010 means the reported usage is accurate to + +/- 10.1 percent. + + This value is zero if the accuracy is unknown." + ::= { eoEnergyEntry 6 } + + eoEnergyMaxConsumed OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Watt-hours" + MAX-ACCESS read-only + STATUS current + + + +Chandramouli, et al. Standards Track [Page 44] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "This object is the maximum energy observed in + eoEnergyConsumed since the monitoring started or was + reinitialized. This value is specified in the common + billing units of watt-hours with the magnitude of + watt-hours (kWh, MWh, etc.) indicated separately in + eoEnergyUnitMultiplier." + ::= { eoEnergyEntry 7 } + + eoEnergyMaxProduced OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "Watt-hours" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the maximum energy ever observed in + eoEnergyEnergyProduced since the monitoring started. This + value is specified in the units of watt-hours with the + magnitude of watt-hours (kWh, MWh, etc.) indicated + separately in eoEnergyEnergyUnitMultiplier." + ::= { eoEnergyEntry 8 } + + eoEnergyDiscontinuityTime OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime RFC 3418 on the most recent + occasion at which any one or more of this entity's energy + counters in this table suffered a discontinuity: + eoEnergyConsumed, eoEnergyProvided or eoEnergyStored. If + no such discontinuities have occurred since the last + re-initialization of the local management subsystem, then + this object contains a zero value." + REFERENCE + "RFC 3418: Management Information Base (MIB) for the + Simple Network Management Protocol (SNMP)" + ::= { eoEnergyEntry 9 } + + -- Notifications + + eoPowerEnableStatusNotification + OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + + + + + +Chandramouli, et al. Standards Track [Page 45] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "This object controls whether the system produces + notifications for eoPowerStateChange. A false value will + prevent these notifications from being generated." + DEFVAL { false } + ::= { energyObjectMibNotifs 1 } + + eoPowerStateChange NOTIFICATION-TYPE + OBJECTS {eoPowerAdminState, eoPowerOperState, + eoPowerStateEnterReason} + STATUS current + DESCRIPTION + "The SNMP entity generates the eoPowerStateChange when + the values of eoPowerAdminState or eoPowerOperState, + in the context of the Power State Set, have changed for + the Energy Object represented by the entPhysicalIndex." + ::= { energyObjectMibNotifs 2 } + + -- Conformance + + energyObjectMibCompliances OBJECT IDENTIFIER + ::= { energyObjectMibConform 1 } + + energyObjectMibGroups OBJECT IDENTIFIER + ::= { energyObjectMibConform 2 } + energyObjectMibFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "When this MIB is implemented with support for + read-create, then such an implementation can + claim full compliance. Such devices can then + be both monitored and configured with this MIB. + + Module Compliance of RFC 6933 + with respect to entity4CRCompliance MUST + be supported, which requires implementation + of four MIB objects: entPhysicalIndex, entPhysicalClass, + entPhysicalName and entPhysicalUUID." + REFERENCE + "RFC 6933: Entity MIB (Version 4)" + MODULE -- this module + MANDATORY-GROUPS { + energyObjectMibTableGroup, + energyObjectMibStateTableGroup, + eoPowerEnableStatusNotificationGroup, + energyObjectMibNotifGroup + } + + + + +Chandramouli, et al. Standards Track [Page 46] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + GROUP energyObjectMibEnergyTableGroup + DESCRIPTION + "A compliant implementation does not + have to implement." + + GROUP energyObjectMibEnergyParametersTableGroup + DESCRIPTION + "A compliant implementation does not + have to implement." + + GROUP energyObjectMibMeterCapabilitiesTableGroup + DESCRIPTION + "A compliant implementation does not + have to implement." + ::= { energyObjectMibCompliances 1 } + + energyObjectMibReadOnlyCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "When this MIB is implemented without support for + read-create (i.e., in read-only mode), then such an + implementation can claim read-only compliance. Such a + device can then be monitored but cannot be + configured with this MIB. + + Module Compliance of [RFC6933] with respect to + entity4CRCompliance MUST be supported which requires + implementation of 4 MIB objects: entPhysicalIndex, + entPhysicalClass, entPhysicalName and entPhysicalUUID." + REFERENCE + "RFC 6933: Entity MIB (Version 4)" + MODULE -- this module + MANDATORY-GROUPS { + energyObjectMibTableGroup, + energyObjectMibStateTableGroup, + energyObjectMibNotifGroup + } + + ::= { energyObjectMibCompliances 2 } + + -- Units of Conformance + + energyObjectMibTableGroup OBJECT-GROUP + OBJECTS { + eoPower, + eoPowerNameplate, + eoPowerUnitMultiplier, + eoPowerAccuracy, + + + +Chandramouli, et al. Standards Track [Page 47] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoPowerMeasurementCaliber, + eoPowerCurrentType, + eoPowerMeasurementLocal, + eoPowerAdminState, + eoPowerOperState, + eoPowerStateEnterReason + } + STATUS current + DESCRIPTION + "This group contains the collection of all the objects + related to the Energy Object." + ::= { energyObjectMibGroups 1 } + + energyObjectMibStateTableGroup OBJECT-GROUP + OBJECTS { + eoPowerStateMaxPower, + eoPowerStatePowerUnitMultiplier, + eoPowerStateTotalTime, + eoPowerStateEnterCount + } + STATUS current + DESCRIPTION + "This group contains the collection of all the objects + related to the Power State." + ::= { energyObjectMibGroups 2 } + + energyObjectMibEnergyParametersTableGroup OBJECT-GROUP + OBJECTS { + eoEnergyParametersIntervalLength, + eoEnergyParametersIntervalNumber, + eoEnergyParametersIntervalMode, + eoEnergyParametersIntervalWindow, + eoEnergyParametersSampleRate, + eoEnergyParametersStorageType, + eoEnergyParametersStatus + } + STATUS current + DESCRIPTION + "This group contains the collection of all the objects + related to the configuration of the Energy Table." + ::= { energyObjectMibGroups 3 } + + energyObjectMibEnergyTableGroup OBJECT-GROUP + OBJECTS { + -- Note that object + -- eoEnergyCollectionStartTime is not + -- included since it is not-accessible + + + + +Chandramouli, et al. Standards Track [Page 48] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoEnergyConsumed, + eoEnergyProvided, + eoEnergyStored, + eoEnergyUnitMultiplier, + eoEnergyAccuracy, + eoEnergyMaxConsumed, + eoEnergyMaxProduced, + eoEnergyDiscontinuityTime + } + STATUS current + DESCRIPTION + "This group contains the collection of all the objects + related to the Energy Table." + ::= { energyObjectMibGroups 4 } + + energyObjectMibMeterCapabilitiesTableGroup OBJECT-GROUP + OBJECTS { + eoMeterCapability + } + STATUS current + DESCRIPTION + "This group contains the object indicating the capability + of the Energy Object" + ::= { energyObjectMibGroups 5 } + + eoPowerEnableStatusNotificationGroup OBJECT-GROUP + OBJECTS { eoPowerEnableStatusNotification } + STATUS current + DESCRIPTION + "The collection of objects that are used to enable + notification." + ::= { energyObjectMibGroups 6 } + + energyObjectMibNotifGroup NOTIFICATION-GROUP + NOTIFICATIONS { + eoPowerStateChange + } + STATUS current + DESCRIPTION + "This group contains the notifications for + the Monitoring and Control MIB for Power and Energy." + ::= { energyObjectMibGroups 7 } + + END + + + + + + + +Chandramouli, et al. Standards Track [Page 49] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +9.3. The POWER-ATTRIBUTES-MIB MIB Module + + -- ************************************************************ + -- + -- This MIB module is used to monitor power attributes of + -- networked devices with measurements. + -- + -- This MIB module is an extension of energyObjectMib module. + -- + -- ************************************************************* + + POWER-ATTRIBUTES-MIB DEFINITIONS ::= BEGIN + + IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + mib-2, + Integer32, Unsigned32 + FROM SNMPv2-SMI + MODULE-COMPLIANCE, + OBJECT-GROUP + FROM SNMPv2-CONF + UnitMultiplier + FROM ENERGY-OBJECT-MIB + entPhysicalIndex + FROM ENTITY-MIB; + + powerAttributesMIB MODULE-IDENTITY + LAST-UPDATED "201502090000Z" -- 9 February 2015 + ORGANIZATION "IETF EMAN Working Group" + CONTACT-INFO + "WG charter: + http://datatracker.ietf.org/wg/eman/charter/ + + Mailing Lists: + General Discussion: eman@ietf.org + + To Subscribe: + https://www.ietf.org/mailman/listinfo/eman + + Archive: + http://www.ietf.org/mail-archive/web/eman + + + + + + + + + +Chandramouli, et al. Standards Track [Page 50] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + Editors: + + Mouli Chandramouli + Cisco Systems, Inc. + Sarjapur Outer Ring Road + Bangalore 560103 + India + Phone: +91 80 4429 2409 + Email: moulchan@cisco.com + + Brad Schoening + 44 Rivers Edge Drive + Little Silver, NJ 07739 + United States + Email: brad.schoening@verizon.net + + Juergen Quittek + NEC Europe Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + Heidelberg 69115 + Germany + Phone: +49 6221 4342-115 + Email: quittek@neclab.eu + + Thomas Dietz + NEC Europe Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + 69115 Heidelberg + Germany + Phone: +49 6221 4342-128 + Email: Thomas.Dietz@nw.neclab.eu + + Benoit Claise + Cisco Systems, Inc. + De Kleetlaan 6a b1 + Degem 1831 + Belgium + Phone: +32 2 704 5622 + Email: bclaise@cisco.com" + + + + + + + + +Chandramouli, et al. Standards Track [Page 51] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "Copyright (c) 2015 IETF Trust and the persons identified as + authors of the code. All rights reserved. + + Redistribution and use in source and binary forms, with or + without modification, is permitted pursuant to, and subject + to the license terms contained in, the Simplified BSD License + set forth in Section 4.c of the IETF Trust's Legal Provisions + Relating to IETF Documents + (http://trustee.ietf.org/license-info). + + This MIB is used to report AC power attributes in devices. + The table is a sparse augmentation of the eoPowerTable table + from the energyObjectMib module. Both three-phase and + single-phase power configurations are supported. + + As a requirement for this MIB module, RFC 7461 SHOULD be + implemented. + + Module Compliance of ENTITY-MIB v4 with respect to + entity4CRCompliance MUST be supported which requires + implementation of four MIB objects: entPhysicalIndex, + entPhysicalClass, entPhysicalName, and entPhysicalUUID." + REVISION "201502090000Z" -- 9 February 2015 + DESCRIPTION + "Initial version, published as RFC 7460" + + ::= { mib-2 230 } + + powerAttributesMIBConform OBJECT IDENTIFIER + ::= { powerAttributesMIB 0 } + + powerAttributesMIBObjects OBJECT IDENTIFIER + ::= { powerAttributesMIB 1 } + + -- Objects + + eoACPwrAttributesTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoACPwrAttributesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains power attributes measurements for + supported entPhysicalIndex entities. It is a sparse + extension of the eoPowerTable." + ::= { powerAttributesMIBObjects 1 } + + eoACPwrAttributesEntry OBJECT-TYPE + + + +Chandramouli, et al. Standards Track [Page 52] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + SYNTAX EoACPwrAttributesEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This is a sparse extension of the eoPowerTable with + entries for power attributes measurements or + configuration. Each measured value corresponds to an + attribute in IEC 61850-7-4 for non-phase measurements + within the object MMXN." + INDEX { entPhysicalIndex } + ::= { eoACPwrAttributesTable 1 } + + EoACPwrAttributesEntry ::= SEQUENCE { + eoACPwrAttributesConfiguration INTEGER, + eoACPwrAttributesAvgVoltage Integer32, + eoACPwrAttributesAvgCurrent Unsigned32, + eoACPwrAttributesFrequency Integer32, + eoACPwrAttributesPowerUnitMultiplier UnitMultiplier, + eoACPwrAttributesPowerAccuracy Integer32, + eoACPwrAttributesTotalActivePower Integer32, + eoACPwrAttributesTotalReactivePower Integer32, + eoACPwrAttributesTotalApparentPower Integer32, + eoACPwrAttributesTotalPowerFactor Integer32, + eoACPwrAttributesThdCurrent Integer32, + eoACPwrAttributesThdVoltage Integer32 + } + + eoACPwrAttributesConfiguration OBJECT-TYPE + SYNTAX INTEGER { + sngl(1), + del(2), + wye(3) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Configuration describes the physical configurations of + the power supply lines: + + * alternating current, single phase (SNGL) + * alternating current, three-phase delta (DEL) + * alternating current, three-phase Y (WYE) + + Three-phase configurations can be either connected in a + triangular delta (DEL) or star Y (WYE) system. WYE + systems have a shared neutral voltage, while DEL systems + do not. Each phase is offset 120 degrees to each other." + ::= { eoACPwrAttributesEntry 1 } + + + +Chandramouli, et al. Standards Track [Page 53] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoACPwrAttributesAvgVoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Volt AC" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value for average of the voltage measured + over an integral number of AC cycles. For a three-phase + system, this is the average voltage (V1+V2+V3)/3. IEC + 61850-7-4 measured value attribute 'Vol'." + ::= { eoACPwrAttributesEntry 2 } + + eoACPwrAttributesAvgCurrent OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "amperes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value for average of the current measured + over an integral number of AC cycles. For a three-phase + system, this is the average current (I1+I2+I3)/3. IEC + 61850-7-4 attribute 'Amp'." + ::= { eoACPwrAttributesEntry 3 } + + eoACPwrAttributesFrequency OBJECT-TYPE + SYNTAX Integer32 (4500..6500) + UNITS "0.01 hertz" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value for the basic frequency of the AC + circuit. IEC 61850-7-4 attribute 'Hz'." + ::= { eoACPwrAttributesEntry 4 } + + eoACPwrAttributesPowerUnitMultiplier OBJECT-TYPE + SYNTAX UnitMultiplier + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The magnitude of watts for the usage value in + eoACPwrAttributesTotalActivePower, + eoACPwrAttributesTotalReactivePower, + and eoACPwrAttributesTotalApparentPower measurements. + For three-phase power systems, this will also include + eoACPwrAttributesWyeActivePower, + eoACPwrAttributesWyeReactivePower, and + eoACPwrAttributesWyeApparentPower." + ::= { eoACPwrAttributesEntry 5 } + + + +Chandramouli, et al. Standards Track [Page 54] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + eoACPwrAttributesPowerAccuracy OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates a percentage value, in hundredths of a + percent, representing the presumed accuracy of active, + reactive, and apparent power usage reporting. For + example, 1010 means the reported usage is accurate to +/- + 10.1 percent. This value is zero if the accuracy is + unknown. + + ANSI and IEC define the following accuracy classes for + power measurement: IEC 62053-22 & 60044-1 class 0.1, 0.2, + 0.5, 1, & 3. + ANSI C12.20 class 0.2 & 0.5" + ::= { eoACPwrAttributesEntry 6 } + + eoACPwrAttributesTotalActivePower OBJECT-TYPE + SYNTAX Integer32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of the actual power delivered to or + consumed by the load. IEC 61850-7-4 attribute 'TotW'." + ::= { eoACPwrAttributesEntry 7 } + + eoACPwrAttributesTotalReactivePower OBJECT-TYPE + SYNTAX Integer32 + UNITS "volt-amperes reactive" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of the reactive portion of the apparent + power. IEC 61850-7-4 attribute 'TotVAr'." + ::= { eoACPwrAttributesEntry 8 } + + eoACPwrAttributesTotalApparentPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "volt-amperes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of the voltage and current that + determines the apparent power. The apparent power is the + vector sum of real and reactive power. + + + +Chandramouli, et al. Standards Track [Page 55] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + Note: watts and volt-amperes are equivalent units and may + be combined. IEC 61850-7-4 attribute 'TotVA'." + ::= { eoACPwrAttributesEntry 9 } + + eoACPwrAttributesTotalPowerFactor OBJECT-TYPE + SYNTAX Integer32 (-10000..10000) + UNITS "hundredths" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value ratio of the real power flowing to the + load versus the apparent power. It is dimensionless and + expressed here as a percentage value in hundredths. A power + factor of 100% indicates there is no inductance load and + thus no reactive power. A Power Factor can be positive or + negative, where the sign should be in lead/lag (IEEE) + form. IEC 61850-7-4 attribute 'TotPF'." + ::= { eoACPwrAttributesEntry 10 } + + eoACPwrAttributesThdCurrent OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A calculated value for the current total harmonic + distortion (THD). Method of calculation is not + specified. IEC 61850-7-4 attribute 'ThdAmp'." + ::= { eoACPwrAttributesEntry 11 } + + eoACPwrAttributesThdVoltage OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A calculated value for the voltage total harmonic + distortion (THD). The method of calculation is not + specified. IEC 61850-7-4 attribute 'ThdVol'." + ::= { eoACPwrAttributesEntry 12 } + + eoACPwrAttributesDelPhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoACPwrAttributesDelPhaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This optional table describes three-phase power attributes + measurements in a DEL configuration with phase-to-phase + + + +Chandramouli, et al. Standards Track [Page 56] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + power attributes measurements. Entities having single + phase power shall not have any entities. This is a + sparse extension of the eoACPwrAttributesTable. + + These attributes correspond to measurements related to + the IEC 61850-7.4 MMXU phase and measured harmonic or + interharmonics related to the MHAI phase." + ::= { powerAttributesMIBObjects 2 } + + eoACPwrAttributesDelPhaseEntry OBJECT-TYPE + SYNTAX EoACPwrAttributesDelPhaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry describes power measurements of a phase in a + DEL three-phase power. Three entries are required for each + supported entPhysicalIndex entry. Voltage measurements + are provided relative to each other. + + For phase-to-phase measurements, the + eoACPwrAttributesDelPhaseIndex is compared against the + following phase at +120 degrees. Thus, the possible + values are: + + eoACPwrAttributesDelPhaseIndex Next Phase Angle + 0 120 + 120 240 + 240 0 + " + INDEX { entPhysicalIndex, eoACPwrAttributesDelPhaseIndex } + ::= { eoACPwrAttributesDelPhaseTable 1} + + EoACPwrAttributesDelPhaseEntry ::= SEQUENCE { + eoACPwrAttributesDelPhaseIndex Integer32, + eoACPwrAttributesDelPhaseToNextPhaseVoltage Integer32, + eoACPwrAttributesDelThdPhaseToNextPhaseVoltage Integer32 + } + + eoACPwrAttributesDelPhaseIndex OBJECT-TYPE + SYNTAX Integer32 (0..359) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A phase angle typically corresponding to 0, 120, 240." + ::= { eoACPwrAttributesDelPhaseEntry 1 } + + eoACPwrAttributesDelPhaseToNextPhaseVoltage OBJECT-TYPE + SYNTAX Integer32 + + + +Chandramouli, et al. Standards Track [Page 57] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + UNITS "0.1 Volt AC" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of phase to next phase voltages, where + the next phase is IEC 61850-7-4 attribute 'PPV'." + ::= { eoACPwrAttributesDelPhaseEntry 2 } + + eoACPwrAttributesDelThdPhaseToNextPhaseVoltage OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A calculated value for the voltage total harmonic + distortion for phase to next phase. Method of calculation + is not specified. IEC 61850-7-4 attribute 'ThdPPV'." + ::= { eoACPwrAttributesDelPhaseEntry 3 } + + eoACPwrAttributesWyePhaseTable OBJECT-TYPE + SYNTAX SEQUENCE OF EoACPwrAttributesWyePhaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This optional table describes three-phase power attributes + measurements in a WYE configuration with phase-to-neutral + power attributes measurements. Entities having single + phase power shall not have any entities. This is a sparse + extension of the eoACPwrAttributesTable. + + These attributes correspond to measurements related to + the IEC 61850-7.4 MMXU phase and measured harmonic or + interharmonics related to the MHAI phase." + ::= { powerAttributesMIBObjects 3 } + + eoACPwrAttributesWyePhaseEntry OBJECT-TYPE + SYNTAX EoACPwrAttributesWyePhaseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table describes measurements of a phase in a WYE + three-phase power system. Three entries are required for + each supported entPhysicalIndex entry. Voltage + measurements are relative to neutral. + + Each entry describes power attributes of one phase of a + WYE three-phase power system." + INDEX { entPhysicalIndex, eoACPwrAttributesWyePhaseIndex } + + + +Chandramouli, et al. Standards Track [Page 58] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + ::= { eoACPwrAttributesWyePhaseTable 1} + + EoACPwrAttributesWyePhaseEntry ::= SEQUENCE { + eoACPwrAttributesWyePhaseIndex Integer32, + eoACPwrAttributesWyePhaseToNeutralVoltage Integer32, + eoACPwrAttributesWyeCurrent Integer32, + eoACPwrAttributesWyeActivePower Integer32, + eoACPwrAttributesWyeReactivePower Integer32, + eoACPwrAttributesWyeApparentPower Integer32, + eoACPwrAttributesWyePowerFactor Integer32, + eoACPwrAttributesWyeThdCurrent Integer32, + eoACPwrAttributesWyeThdPhaseToNeutralVoltage Integer32 + } + + eoACPwrAttributesWyePhaseIndex OBJECT-TYPE + SYNTAX Integer32 (0..359) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A phase angle typically corresponding to 0, 120, 240." + ::= { eoACPwrAttributesWyePhaseEntry 1 } + + eoACPwrAttributesWyePhaseToNeutralVoltage OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 Volt AC" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of phase to neutral voltage. IEC + 61850-7-4 attribute 'PNV'." + ::= { eoACPwrAttributesWyePhaseEntry 2 } + + eoACPwrAttributesWyeCurrent OBJECT-TYPE + SYNTAX Integer32 + UNITS "0.1 amperes AC" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of phase currents. IEC 61850-7-4 + attribute 'A'." + ::= { eoACPwrAttributesWyePhaseEntry 3 } + + eoACPwrAttributesWyeActivePower OBJECT-TYPE + SYNTAX Integer32 + UNITS "watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Chandramouli, et al. Standards Track [Page 59] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + "A measured value of the actual power delivered to or + consumed by the load with the magnitude indicated + separately in eoPowerUnitMultiplier. IEC 61850-7-4 + attribute 'W'." + ::= { eoACPwrAttributesWyePhaseEntry 4 } + + eoACPwrAttributesWyeReactivePower OBJECT-TYPE + SYNTAX Integer32 + UNITS "volt-amperes reactive" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of the reactive portion of the apparent + power with the magnitude of indicated separately in + eoPowerUnitMultiplier. IEC 61850-7-4 attribute 'VAr'." + ::= { eoACPwrAttributesWyePhaseEntry 5 } + + eoACPwrAttributesWyeApparentPower OBJECT-TYPE + SYNTAX Integer32 + UNITS "volt-amperes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value of the voltage and current determines + the apparent power with the indicated separately in + eoPowerUnitMultiplier. Active plus reactive power equals + the total apparent power. + + Note: Watts and volt-amperes are equivalent units and may + be combined. IEC 61850-7-4 attribute 'VA'." + ::= { eoACPwrAttributesWyePhaseEntry 6 } + + eoACPwrAttributesWyePowerFactor OBJECT-TYPE + SYNTAX Integer32 (-10000..10000) + UNITS "hundredths" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A measured value ratio of the real power flowing to the + load versus the apparent power for this phase. IEC + 61850-7-4 attribute 'PF'. Power Factor can be positive or + negative where the sign should be in lead/lag (IEEE) + form." + ::= { eoACPwrAttributesWyePhaseEntry 7 } + + eoACPwrAttributesWyeThdCurrent OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + + + +Chandramouli, et al. Standards Track [Page 60] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A calculated value for the voltage total harmonic + distortion (THD) for phase to phase. Method of + calculation is not specified. + IEC 61850-7-4 attribute 'ThdA'." + ::= { eoACPwrAttributesWyePhaseEntry 8 } + + eoACPwrAttributesWyeThdPhaseToNeutralVoltage OBJECT-TYPE + SYNTAX Integer32 (0..10000) + UNITS "hundredths of percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A calculated value of the voltage total harmonic + distortion (THD) for phase to neutral. IEC 61850-7-4 + attribute 'ThdPhV'." + ::= { eoACPwrAttributesWyePhaseEntry 9 } + + -- Conformance + powerAttributesMIBCompliances OBJECT IDENTIFIER + ::= { powerAttributesMIB 2 } + + powerAttributesMIBGroups OBJECT IDENTIFIER + ::= { powerAttributesMIB 3 } + + powerAttributesMIBFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "When this MIB is implemented with support for read- + create, then such an implementation can claim full + compliance. Such devices can then be both monitored and + configured with this MIB. + + Module Compliance of RFC 6933 with respect to + entity4CRCompliance MUST be supported which requires + implementation of four MIB objects: entPhysicalIndex, + entPhysicalClass, entPhysicalName, and entPhysicalUUID." + REFERENCE + "RFC 6933: Entity MIB (Version 4)" + + MODULE -- this module + MANDATORY-GROUPS { + powerACPwrAttributesMIBTableGroup + } + + GROUP powerACPwrAttributesOptionalMIBTableGroup + + + +Chandramouli, et al. Standards Track [Page 61] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + DESCRIPTION + "A compliant implementation does not have + to implement." + + GROUP powerACPwrAttributesDelPhaseMIBTableGroup + DESCRIPTION + "A compliant implementation does not have to implement." + + GROUP powerACPwrAttributesWyePhaseMIBTableGroup + DESCRIPTION + "A compliant implementation does not have to implement." + ::= { powerAttributesMIBCompliances 1 } + + -- Units of Conformance + + powerACPwrAttributesMIBTableGroup OBJECT-GROUP + OBJECTS { + -- Note that object entPhysicalIndex is NOT + -- included since it is not-accessible + eoACPwrAttributesAvgVoltage, + eoACPwrAttributesAvgCurrent, + eoACPwrAttributesFrequency, + eoACPwrAttributesPowerUnitMultiplier, + eoACPwrAttributesPowerAccuracy, + eoACPwrAttributesTotalActivePower, + eoACPwrAttributesTotalReactivePower, + eoACPwrAttributesTotalApparentPower, + eoACPwrAttributesTotalPowerFactor + } + STATUS current + DESCRIPTION + "This group contains the collection of all the power + attributes objects related to the Energy Object." + ::= { powerAttributesMIBGroups 1 } + + powerACPwrAttributesOptionalMIBTableGroup OBJECT-GROUP + OBJECTS { + eoACPwrAttributesConfiguration, + eoACPwrAttributesThdCurrent, + eoACPwrAttributesThdVoltage + } + STATUS current + DESCRIPTION + "This group contains the collection of all the power + attributes objects related to the Energy Object." + ::= { powerAttributesMIBGroups 2 } + + powerACPwrAttributesDelPhaseMIBTableGroup OBJECT-GROUP + + + +Chandramouli, et al. Standards Track [Page 62] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + OBJECTS { + -- Note that object entPhysicalIndex and + -- eoACPwrAttributesDelPhaseIndex are NOT + -- included since they are not-accessible + eoACPwrAttributesDelPhaseToNextPhaseVoltage, + eoACPwrAttributesDelThdPhaseToNextPhaseVoltage + } + STATUS current + DESCRIPTION + "This group contains the collection of all power + attributes of a phase in a DEL three-phase power system." + ::= { powerAttributesMIBGroups 3 } + + powerACPwrAttributesWyePhaseMIBTableGroup OBJECT-GROUP + OBJECTS { + -- Note that object entPhysicalIndex and + -- eoACPwrAttributesWyePhaseIndex are NOT + -- included since they are not-accessible + eoACPwrAttributesWyePhaseToNeutralVoltage, + eoACPwrAttributesWyeCurrent, + eoACPwrAttributesWyeActivePower, + eoACPwrAttributesWyeReactivePower, + eoACPwrAttributesWyeApparentPower, + eoACPwrAttributesWyePowerFactor, + eoACPwrAttributesWyeThdPhaseToNeutralVoltage, + eoACPwrAttributesWyeThdCurrent + } + STATUS current + DESCRIPTION + "This group contains the collection of all power + attributes of a phase in a WYE three-phase power system." + ::= { powerAttributesMIBGroups 4 } + + END + +10. Security Considerations + + There are a number of management objects defined in this MIB module + with a MAX-ACCESS clause of read-write and/or read-create. Such + objects may be considered sensitive or vulnerable in some network + environments. The support for SET operations in a non-secure + environment without proper protection opens devices to attack. These + are the tables and objects and their sensitivity/vulnerability: + + - Unauthorized changes to the eoPowerOperState (via the + eoPowerAdminState ) MAY disrupt the power settings of the + differentEnergy Objects and, therefore, the state of + functionality of the respective Energy Objects. + + + +Chandramouli, et al. Standards Track [Page 63] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + - Unauthorized changes to the eoEnergyParametersTable MAY disrupt + energy measurement in the eoEnergyTable table. + + SNMP versions prior to SNMPv3 did not include adequate security. + Even if the network itself is secure (for example by using IPsec), + there is no control as to who on the secure network is allowed to + access and GET/SET (read/change/create/delete) the objects in this + MIB module. + + Implementations SHOULD provide the security features described by the + SNMPv3 framework (see [RFC3410]), and implementations claiming + compliance to the SNMPv3 standard MUST include full support for + authentication and privacy via the User-based Security Model (USM) + [RFC3414] with the AES cipher algorithm [RFC3826]. Implementations + MAY also provide support for the Transport Security Model (TSM) + [RFC5591] in combination with a secure transport such as SSH + [RFC5592] or TLS/DTLS [RFC6353]. + + Further, deployment of SNMP versions prior to SNMPv3 is NOT + RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to + enable cryptographic security. It is then a customer/operator + responsibility to ensure that the SNMP entity giving access to an + instance of this MIB module is properly configured to give access to + the objects only to those principals (users) that have legitimate + rights to indeed GET or SET (change/create/delete) them. + + In certain situations, energy and power monitoring can reveal + sensitive information about individuals' activities and habits. + Implementors of this specification should use appropriate privacy + protections as discussed in Section 9 of RFC 6988 and monitoring of + individuals and homes should only occur with proper authorization. + +11. IANA Considerations + + The MIB modules in this document use the following IANA-assigned + OBJECT IDENTIFIER values recorded in the SMI Numbers registry: + + Descriptor OBJECT IDENTIFIER value + ---------- ----------------------- + + IANAPowerStateSet-MIB { mib-2 228 } + + energyObjectMIB { mib-2 229 } + + powerAttributesMIB { mib-2 230 } + + + + + + +Chandramouli, et al. Standards Track [Page 64] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +11.1. IANAPowerStateSet-MIB Module + + The initial set of Power State Sets are specified in [RFC7326]. IANA + maintains a Textual Convention PowerStateSet in the + IANAPowerStateSet-MIB module (see Section 9.1), with the initial set + of Power State Sets and the Power States within those Power State + Sets as proposed in the [RFC7326]. The current version of + PowerStateSet Textual Convention can be accessed + <http://www.iana.org/assignments/power-state-sets>. + + New assignments (and potential deprecation) to Power State Sets shall + be administered by IANA and the guidelines and procedures are + specified in [RFC7326], and will, as a consequence, update the + PowerStateSet Textual Convention. + +12. References + +12.1. Normative References + + [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate + Requirement Levels", BCP 14, RFC 2119, March 1997, + <http://www.rfc-editor.org/info/rfc2119>. + + [RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J. + Schoenwaelder, Ed., "Structure of Management + Information Version 2 (SMIv2)", STD 58, RFC 2578, + April 1999, <http://www.rfc-editor.org/info/rfc2578>. + + [RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J. + Schoenwaelder, Ed., "Textual Conventions for SMIv2", + STD 58, RFC 2579, April 1999, + <http://www.rfc-editor.org/info/rfc2579>. + + [RFC2580] McCloghrie, K., Ed., Perkins, D., Ed., and J. + Schoenwaelder, Ed., "Conformance Statements for + SMIv2", STD 58, RFC 2580, April 1999, + <http://www.rfc-editor.org/info/rfc2580>. + + [RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security + Model (USM) for version 3 of the Simple Network + Management Protocol (SNMPv3)", STD 62, RFC 3414, + December 2002, + <http://www.rfc-editor.org/info/rfc3414>. + + [RFC3621] Berger, A. and D. Romascanu, "Power Ethernet MIB", + RFC 3621, December 2003, + <http://www.rfc-editor.org/info/rfc3621>. + + + + +Chandramouli, et al. Standards Track [Page 65] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + [RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The + Advanced Encryption Standard (AES) Cipher Algorithm + in the SNMP User-based Security Model", RFC 3826, + June 2004, <http://www.rfc-editor.org/info/rfc3826>. + + [RFC5591] Harrington, D. and W. Hardaker, "Transport Security + Model for the Simple Network Management Protocol + (SNMP)", STD 78, RFC 5591, June 2009, + <http://www.rfc-editor.org/info/rfc5591>. + + [RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure + Shell Transport Model for the Simple Network + Management Protocol (SNMP)", RFC 5592, June 2009, + <http://www.rfc-editor.org/info/rfc5592>. + + [RFC6353] Hardaker, W., "Transport Layer Security (TLS) + Transport Model for the Simple Network Management + Protocol (SNMP)", STD 78, RFC 6353, July 2011, + <http://www.rfc-editor.org/info/rfc6353>. + + [RFC6933] Bierman, A., Romascanu, D., Quittek, J., and M. + Chandramouli, "Entity MIB (Version 4)", RFC 6933, May + 2013, <http://www.rfc-editor.org/info/rfc6933>. + + [RFC7461] Parello, J., Claise, B., and M. Chandramouli, "Energy + Object Context MIB", RFC 7461, March 2015, + <http://www.rfc-editor.org/info/rfc7461>. + + [LLDP-MED-MIB] ANSI/TIA-1057, "The LLDP Management Information Base + extension module for TIA-TR41.4 media endpoint + discovery information", July 2005. + +12.2. Informative References + + [RFC1628] Case, J., Ed., "UPS Management Information Base", RFC + 1628, May 1994, + <http://www.rfc-editor.org/info/rfc1628>. + + [RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, + "Introduction and Applicability Statements for + Internet-Standard Management Framework", RFC 3410, + December 2002, + <http://www.rfc-editor.org/info/rfc3410>. + + [RFC3418] Presuhn, R., Ed., "Management Information Base (MIB) + for the Simple Network Management Protocol (SNMP)", + STD 62, RFC 3418, December 2002, + <http://www.rfc-editor.org/info/rfc3418>. + + + +Chandramouli, et al. Standards Track [Page 66] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + [RFC3433] Bierman, A., Romascanu, D., and K. Norseth, "Entity + Sensor Management Information Base", RFC 3433, + December 2002, + <http://www.rfc-editor.org/info/rfc3433>. + + [RFC4268] Chisholm, S. and D. Perkins, "Entity State MIB", RFC + 4268, November 2005, + <http://www.rfc-editor.org/info/rfc4268>. + + [RFC6988] Quittek, J., Ed., Chandramouli, M., Winter, R., + Dietz, T., and B. Claise, "Requirements for Energy + Management", RFC 6988, September 2013, + <http://www.rfc-editor.org/info/rfc6988>. + + [RFC7326] Parello, J., Claise, B., Schoening, B., and J. + Quittek, "Energy Management Framework", RFC 7326, + September 2014, + <http://www.rfc-editor.org/info/rfc7326>. + + [DMTF] DMTF, "Power State Management Profile", DSP1027, + Version 2.0, December 2009, + http://www.dmtf.org/sites/default/files/standards + /documents/DSP1027_2.0.0.pdf + + [EMAN-AS] Schoening, B., Chandramouli, M., and B. Nordman, + "Energy Management (EMAN) Applicability Statement", + Work in Progress, draft-ietf-eman-applicability- + statement-08, December 2014. + + [IEC.61850-7-4] International Electrotechnical Commission, + "Communication networks and systems for power utility + automation -- Part 7-4: Basic communication + structure -- Compatible logical node classes and + data object classes", March 2010. + + [IEC.62053-21] International Electrotechnical Commission, + "Electricity metering equipment (a.c.) -- Particular + requirements -- Part 21: Static meters for active + energy (classes 1 and 2)", January 2003. + + [IEC.62053-22] International Electrotechnical Commission, + "Electricity metering equipment (a.c.) -- Particular + requirements -- Part 22: Static meters for active + energy (classes 0,2 S and 0,5 S)", January 2003. + + + + + + + +Chandramouli, et al. Standards Track [Page 67] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + + [IEEE1621] "Standard for User Interface Elements in Power + Control of Electronic Devices Employed in + Office/Consumer Environments", IEEE 1621, December + 2004. + +Acknowledgments + + The authors would like to thank Shamita Pisal for her prototype of + this MIB module and her valuable feedback. The authors would like to + Michael Brown for improving the text dramatically. + + The authors would like to thank Juergen Schoenwalder for proposing + the design of the Textual Convention for PowerStateSet and Ira + McDonald for his feedback. Special appreciation to Laurent Guise for + his review and input on power quality measurements. Thanks for the + many comments on the design of the EnergyTable from Minoru Teraoka + and Hiroto Ogaki. + + Many thanks to Alan Luchuk for the detailed review of the MIB and his + comments. + + And finally, thanks to the EMAN chairs: Nevil Brownlee and Tom + Nadeau. + +Contributors + + This document results from the merger of two initial proposals. The + following persons made significant contributions either in one of the + initial proposals or in this document: + + John Parello + + Rolf Winter + + Dominique Dudkowski + + + + + + + + + + + + + + + + +Chandramouli, et al. Standards Track [Page 68] + +RFC 7460 Power/Energy Monitoring and Control MIB March 2015 + + +Authors' Addresses + + Mouli Chandramouli + Cisco Systems, Inc. + Sarjapur Outer Ring Road + Bangalore 560103 + India + Phone: +91 80 4429 2409 + EMail: moulchan@cisco.com + + + Benoit Claise + Cisco Systems, Inc. + De Kleetlaan 6a b1 + Diegem 1813 + Belgium + Phone: +32 2 704 5622 + EMail: bclaise@cisco.com + + + Brad Schoening + 44 Rivers Edge Drive + Little Silver, NJ 07739 + United States + EMail: brad.schoening@verizon.net + + + Juergen Quittek + NEC Europe, Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + Heidelberg 69115 + Germany + Phone: +49 6221 4342-115 + EMail: quittek@neclab.eu + + + Thomas Dietz + NEC Europe, Ltd. + NEC Laboratories Europe + Network Research Division + Kurfuersten-Anlage 36 + Heidelberg 69115 + Germany + Phone: +49 6221 4342-128 + EMail: Thomas.Dietz@neclab.eu + + + + +Chandramouli, et al. Standards Track [Page 69] + |