summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc1747.txt
diff options
context:
space:
mode:
Diffstat (limited to 'doc/rfc/rfc1747.txt')
-rw-r--r--doc/rfc/rfc1747.txt3755
1 files changed, 3755 insertions, 0 deletions
diff --git a/doc/rfc/rfc1747.txt b/doc/rfc/rfc1747.txt
new file mode 100644
index 0000000..8cc6366
--- /dev/null
+++ b/doc/rfc/rfc1747.txt
@@ -0,0 +1,3755 @@
+
+
+
+
+
+
+Network Working Group J. Hilgeman, Chair
+Request for Comments: 1747 Apertus Technologies, Inc.
+Category: Standards Track S. Nix
+ Metaplex, Inc.
+ A. Bartky
+ Sync Research, Inc.
+ W. Clark, Editor
+ cisco Systems, Inc.
+ January 1995
+
+
+ Definitions of Managed Objects for SNA Data Link Control (SDLC)
+ using SMIv2
+
+Status of this Memo
+
+ This document specifies an Internet standards track protocol for the
+ Internet community, and requests discussion and suggestions for
+ improvements. Please refer to the current edition of the "Internet
+ Official Protocol Standards" (STD 1) for the standardization state
+ and status of this protocol. Distribution of this memo is unlimited.
+
+Abstract
+
+ This specification defines an extension to the Management Information
+ Base (MIB) for use with SNMP-based network management. In
+ particular, it defines objects for managing the configuration,
+ monitoring and control of data link controls in an SNA environment.
+ This draft identifies managed objects for SNA Synchronous Data Link
+ Control (SDLC) links only.
+
+Table of Contents
+
+ 1. The SNMPv2 Network Management Framework ................. 2
+ 1.1 Object Definitions .................................... 2
+ 2. Overview ................................................ 2
+ 2.1 Tables Defined in the SNADLC SDLC MIB ................. 3
+ 2.2 Row Creation Mechanism ................................ 3
+ 2.3 Relationship to the Interfaces Group .................. 4
+ 3. Definitions ............................................. 7
+ 3.1 Port Administrative Table ............................. 9
+ 3.2 Port Operational Table ............................... 14
+ 3.3 Port Statistics Table ................................ 20
+ 3.4 Link Station Administrative Table .................... 26
+ 3.5 Link Station Operational Table ....................... 35
+ 3.6 Link Station Statistics Table ........................ 44
+ 3.7 Trap Definitions ..................................... 56
+ 3.8 Compliance Statements ................................ 57
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 1]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ 4. Acknowledgments ........................................ 65
+ 5. References ............................................. 65
+ 6. Glossary ............................................... 66
+ 7. Security Considerations ................................ 67
+ 8. Authors' Addresses ..................................... 67
+
+1. The SNMPv2 Network Management Framework
+
+ The SNMPv2 Network Management Framework consists of four major
+ components. They are:
+
+ o RFC 1441 which defines the SMI, the mechanisms used for
+ describing and naming objects for the purpose of management.
+
+ o STD 17, RFC 1213 defines MIB-II, the core set of managed
+ objects for the Internet suite of protocols.
+
+ o RFC 1445 which defines the administrative and other
+ architectural aspects of the framework.
+
+ o RFC 1448 which defines the protocol used for network access
+ to managed objects.
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+1.1. Object Definitions
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation One (ASN.1)
+ defined in the SMI. In particular, each object object type is named
+ by an OBJECT IDENTIFIER, an administratively assigned name. The
+ object type together with an object instance serves to uniquely
+ identify a specific instantiation of the object. For human
+ convenience, we often use a textual string, termed the descriptor, to
+ refer to the object type.
+
+2. Overview
+
+ This memo identifies the proposed set of objects for configuring,
+ monitoring, and controlling SDLC ports and link stations.
+
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 2]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+2.1. Tables Defined in the SNADLC SDLC MIB
+
+ The SNADLC MIB is composed of two managed entities with three tables
+ each. The two managed entities for SDLC are:
+
+ o Ports: the physical connection, and
+
+ o Link Stations: the logical connections on the Port.
+
+ The three management tables are:
+
+ o Adminstration: objects used for configuring and controlling
+ the operation of a Port or Link Station,
+
+ o Operational: objects that reflect the run-time state of the
+ Port or Link Station, and
+
+ o Statistics: objects that reflect the operating metrics of the
+ Port or Link Station.
+
+ Considering the above combinations, the following are the actual
+ tables found in this MIB:
+
+ 1) Port Administration Table,
+
+ 2) Port Operation Table,
+
+ 3) Port Statistics Table,
+
+ 4) Link Station Administration Table,
+
+ 5) Link Station Operation Table,
+
+ 6) Link Station Statistics Table.
+
+ All variables in this MIB relate to SDLC ports and link stations
+ only. Any variable relating to higher-layer entities in SNA such as
+ Physical Units (PU) and Logical Units (LU) are found in the SNA NAU
+ MIB [4].
+
+2.2. Row Creation Mechanism
+
+ Row creation mechanism for the sdlcLSAdminTable is based on the use
+ of the RowStatus object. It follows the rules for the use in SNMPv1
+ context proposed in the memo "Row creation with SNMPv1" [5]. Before
+ accepting the destroy value for an entry, an agent has to verify the
+ operational state of the corresponding entry in the sdlcLSOperTable
+ entry.
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 3]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+2.3. Relationship to the Interfaces Group
+
+ This memo shall conform to the recommendations of [6].
+
+ The SDLC layer of each SDLC Port shall be modeled by a row in the
+ ifTable with an ifType using the IANA assigned number for SDLC (17).
+ Each SDLC port interface must comply with the following conformance
+ groups in [6]:
+
+ - ifGeneralGroup
+ - ifStackGroup
+ - ifPacketGroup
+
+ An implementation may optionally comply with the ifTestGroup defined
+ in that memo to execute vendor specific tests. An example of this
+ would be to perform LPDA test functions.
+
+ The SDLC port's relation with its physical, or lower-layer interface
+ (i.e., RS-232, V.35, etc.) shall be modeled by a row in the
+ ifStackTable with the ifStackHigherLayer pointing to the SDLC port
+ ifTable instance and the ifStackLowerLayer pointing to the physical
+ media-specific ifTable instance. The media-specific objects of these
+ lower-layer interfaces will, of course, be described in their
+ respective MIBs (i.e., [1]).
+
+ The following table provides specific implementation guidelines for
+ all the interface group objects listed in the conformance tables
+ above.
+
+Object Use for an SDLC Port
+
+ifIndex Each SDLC port is represented by an ifEntry. All
+ SDLC port tables shall be indexed by ifIndex.
+
+ifDescr Description of the SDLC port.
+
+ifType The IANA value reserved for SDLC - 17.
+
+ifMtu Refer to [6].
+
+ifSpeed This object shall reflect the value of the
+ corresponding object in the ifEntry of the
+ associated lower-layer interface.
+
+ifPhysAddress A string denoting the physical location of the SDLC
+ port within its node. This shall have unique
+ significance within each implementing node.
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 4]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ifAdminStatus This object shall reflect the value of the
+ corresponding object in the ifEntry of the
+ associated lower-layer interface.
+
+ifOperStatus This object shall reflect the value of the
+ corresponding object in the ifEntry of the
+ associated lower-layer interface.
+
+ifLastChange Refer to [6].
+
+ifInOctets Refer to [6].
+
+ifInUcastPkts This object shall count packets received from a
+ specific SDLC poll address. Packets for the SDLC
+ broadcast address of x'FF' are not counted.
+
+ifInDiscards Refer to [6].
+
+ifInErrors Refer to [6]. Specific counters for these errors
+ are kept in the sdlcPortStatsTable.
+
+ifInUnknownProtos This counter shall return zero for SDLC ports.
+
+ifOutOctets Refer to [6].
+
+ifOutUcastPkts This object shall count packets transmitted to a
+ specific SDLC poll address (not x'FF').
+
+ifOutDiscards Refer to [6].
+
+ifOutErrors Refer to [6]. Specific counters for these errors
+ are kept in the sdlcPortStatsTable.
+
+ifName The textual name of the SDLC port or an octet string
+ of zero length.
+
+ifInMulticastPkts The value is 0 (not applicable to the SDLC layer).
+
+ifInBroadcastPkts This object shall count packets received on this
+ interface addressed to the SDLC broadcast address
+ (x'FF'). Only point-to-point ports supporting a
+ secondary switched station should return non-zero
+ values.
+
+ifOutMulticastPkts The value is 0 (not applicable to the SDLC layer).
+
+ifOutBroadcastPkts This object shall count packets transmitted on this
+ interface which were addressed to the SDLC broadcast
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 5]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ address (x'FF'). Only point-to-point ports
+ supporting a primary switched station should
+ return non-zero values.
+
+ifHC* Not part of the conformance group.
+
+ifLinkUpDownTrapEnable
+ Refer to [6]. Default is disabled (2).
+
+ifHighSpeed Refer to [6].
+
+ifPromiscuousMode Should return false if this interface receives only
+ packets addressed to its SDLC poll address(es).
+ However, in certain implementations, the lower-layer
+ interface shall present all frames to the SDLC port
+ regardless of the poll address. Such frames may be
+ the result of a misconfigured peer or the secondary
+ end of a multipoint connection. Such
+ implementations should return true for this
+ object.
+
+ifConnectorPresent Set to 'false'.
+
+ifStackHigherLayer For each SDLC port there will be an ifStackEntry
+ with this object's value referring to the ifIndex of
+ the SDLC port's ifEntry for the SDLC layer.
+
+ifStackLowerLayer For each SDLC port there will be an ifStackEntry
+ with this object's value referring to the ifIndex of
+ the physical layer interface's ifEntry for that SDLC
+ port.
+
+ifStackStatus Refer to [6].
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 6]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+3. Definitions
+
+SNA-SDLC-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Counter32, Integer32, TimeTicks
+ FROM SNMPv2-SMI
+ DisplayString, RowStatus, TimeInterval
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP
+ FROM SNMPv2-CONF
+ mib-2, ifIndex, ifAdminStatus, ifOperStatus
+ FROM RFC1213-MIB;
+
+
+snaDLC MODULE-IDENTITY
+ LAST-UPDATED "9411150000Z"
+ ORGANIZATION "IETF SNA DLC MIB Working Group"
+ CONTACT-INFO
+ " Wayne Clark
+
+ Postal: cisco Systems, Inc.
+ 3100 Smoketree Ct.
+ Suite 1000
+ Raleigh, NC 27604
+ US
+
+ Tel: +1 919 878 6958
+
+ E-Mail: wclark@cisco.com"
+
+ DESCRIPTION
+ "This is the MIB module for objects used to
+ manage SDLC devices."
+
+::= { mib-2 41 }
+
+--
+-- The following data link controls are modelled in this MIB module:
+--
+-- 1. SDLC
+--
+
+sdlc OBJECT IDENTIFIER ::= { snaDLC 1 }
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 7]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+--
+-- THE SDLC GROUP
+-- ==============
+--
+-- The following resources are modelled in the SDLC group of this
+-- MIB module:
+--
+-- 1. PORTS
+-- 2. LINK STATIONS
+
+sdlcPortGroup OBJECT IDENTIFIER ::= { sdlc 1 } -- Physical Ports
+sdlcLSGroup OBJECT IDENTIFIER ::= { sdlc 2 } -- Logical Link Stations
+
+--
+-- THE SDLC PORT GROUP
+-- ===================
+--
+-- The following classes of information is modelled for each SDLC port:
+--
+-- 1. ADMINISTRATIVE ( read/write)
+-- 2. OPERATIONAL ( read-only)
+-- 3. STATISTICS ( read-only)
+
+-- Information not found in this group is found in tables described in
+-- the following RFCs:
+--
+-- 1. RFC1213 - MIB-II
+--
+-- TABLE INDEX
+-- ==================== ====================
+-- a. ifTable ifIndex
+--
+-- 2. RFC1659 - The RS232-like MIB
+--
+-- TABLE INDEX
+-- ==================== ====================
+-- a. rs232PortTable rs232PortIndex
+-- b. rs232SyncPortTable rs232SyncPortIndex
+-- c. rs232InSigTable rs232InSigPortIndex,
+-- rs232InSigName
+-- d. rs232OutSigTable rs232OutSigPortIndex,
+-- rs232OutSigName
+-- ** e. rs232AsyncPortTable rs232AsyncPortIndex
+--
+-- ** rs232AsyncPortTable for ISO 3309.3 ( Start-Stop SDLC).
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 8]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+-- *************************************************************
+-- * *
+-- * THE SDLC PORT ADMINISTRATIVE TABLE *
+-- * *
+-- *************************************************************
+
+sdlcPortAdminTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcPortAdminEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects that can be
+ changed to manage an SDLC port. Changing one
+ of these parameters may take effect in the
+ operating port immediately or may wait until
+ the interface is restarted depending on the
+ details of the implementation.
+
+ Most of the objects in this read-write table
+ have corresponding read-only objects in the
+ sdlcPortOperTable that return the current
+ operating value.
+
+ The operating values may be different from
+ these configured values if a configured
+ parameter was changed after the interface was
+ started."
+ ::= { sdlcPortGroup 1 }
+
+sdlcPortAdminEntry OBJECT-TYPE
+ SYNTAX SdlcPortAdminEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of configured values for an SDLC port."
+ INDEX { ifIndex }
+ ::= { sdlcPortAdminTable 1 }
+
+SdlcPortAdminEntry ::= SEQUENCE
+{
+ sdlcPortAdminName DisplayString,
+ sdlcPortAdminRole INTEGER,
+ sdlcPortAdminType INTEGER,
+ sdlcPortAdminTopology INTEGER,
+ sdlcPortAdminISTATUS INTEGER,
+ sdlcPortAdminACTIVTO TimeInterval,
+ sdlcPortAdminPAUSE TimeInterval,
+ sdlcPortAdminSERVLIM Integer32,
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 9]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ sdlcPortAdminSlowPollTimer TimeInterval
+}
+
+sdlcPortAdminName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..10))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "An octet string that defines the physical port
+ to which this interface is assigned. It has
+ implementation-specific significance. Its value
+ shall be unique within the administered
+ system. It must contain only ASCII printable
+ characters. Should an implementation choose to
+ accept a write operation for this object, it
+ causes the logical port definition associated
+ with the table instance to be moved to a
+ different physical port. A write operation
+ shall not take effect until the port is cycled
+ inactive."
+ ::= { sdlcPortAdminEntry 1 }
+
+sdlcPortAdminRole OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ primary(1),
+ secondary(2),
+ negotiable(3)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object describes the role that the link
+ station shall assume the next time a connection
+ is established.
+
+ Even though this is defined as a port object,
+ it is a link station attribute in the sense
+ that a role is per link station. However, it
+ is not possible to vary link station roles on a
+ particular port. For example, if an SDLC port
+ is configured to primary, all link stations on
+ that port must be primary."
+ ::= { sdlcPortAdminEntry 2 }
+
+sdlcPortAdminType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 10]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ leased(1),
+ switched(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter defines whether the SDLC port
+ is to connect to a leased or switched line. A
+ write operation to this administrative value
+ shall not take effect until the SDLC port has
+ been cycled inactive."
+ DEFVAL { leased }
+ ::= { sdlcPortAdminEntry 3 }
+
+sdlcPortAdminTopology OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ pointToPoint(1),
+ multipoint(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter defines whether the SDLC port is
+ capable of operating in either a point-to-point
+ or multipoint topology.
+
+ sdlcPortAdminTopology == multipoint implies the
+ port can also operate in a point-to-point
+ topology. sdlcPortAdminTopology ==
+ pointToPoint does not imply the port can
+ operate in a multipoint topology.
+
+ A write operation to this administrative value
+ shall not take effect until the SDLC port has
+ been cycled inactive."
+ DEFVAL { pointToPoint }
+ ::= { sdlcPortAdminEntry 4 }
+
+sdlcPortAdminISTATUS OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inactive(1),
+ active(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 11]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "This parameter controls the initial value of
+ the administrative status, ifAdminStatus, of
+ this SDLC port at port start-up. Depending
+ on the implementation, a write operation to
+ this administrative object may not take effect
+ until the SDLC port has been cycled inactive."
+ DEFVAL { active }
+ ::= { sdlcPortAdminEntry 5 }
+
+sdlcPortAdminACTIVTO OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This parameter defines the period of time (in
+ 1/100ths of a second) that the port will allow a
+ switched line to remain inactive before
+ disconnecting. A switched line is considered
+ to be inactive if there are no I-Frames being
+ transferred. A value of zero indicates no
+ timeout. Depending on the implementation, a
+ write operation to this administered value may
+ not take effect until the port is cycled
+ inactive.
+
+ This object only has meaning for SDLC ports
+ where sdlcPortAdminType == switched
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, ACTIVTO. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP ACTIVTO is
+ represented in seconds."
+ DEFVAL { 0 }
+ ::= { sdlcPortAdminEntry 6 }
+
+sdlcPortAdminPAUSE OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the minimum elapsed time
+ (in 1/100ths of a second) between any two
+ traversals of the poll list for a primary SDLC
+ port. Depending on the implementation, a write
+ operation to this administered value may not
+ take effect until the port is cycled inactive.
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 12]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, PAUSE. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP PAUSE is
+ represented in 1/10ths of a second.
+
+ This object only has meaning for SDLC ports
+ where sdlcPortAdminRole == primary "
+ DEFVAL { 200 }
+ ::= { sdlcPortAdminEntry 7 }
+
+sdlcPortAdminSERVLIM OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object defines the number of times the
+ active poll list will be traversed before
+ polling a station on the slow poll list for a
+ primary, multipoint SDLC port. Depending on
+ the implementation, a write operation to this
+ administered value may not take effect until
+ the port is cycled inactive.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortAdminRole == primary
+ and
+ sdlcPortAdminTopology == multipoint "
+ DEFVAL { 20 }
+ ::= { sdlcPortAdminEntry 8 }
+
+sdlcPortAdminSlowPollTimer OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object describes the elapsed time (in
+ 1/100ths of a second) between polls for failed
+ secondary link station addresses. Depending
+ on the implementation, a write operation to
+ this administered value may not take effect
+ until the port is cycled inactive.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortAdminRole == primary
+ and
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 13]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ sdlcPortAdminTopology == multipoint "
+ DEFVAL { 2000 }
+ ::= { sdlcPortAdminEntry 9 }
+
+-- *************************************************************
+-- * *
+-- * THE SDLC PORT OPERATIONAL TABLE *
+-- * *
+-- *************************************************************
+
+sdlcPortOperTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcPortOperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains current SDLC port
+ parameters. Many of these objects have
+ corresponding objects inthe sdlcPortAdminTable."
+ ::= { sdlcPortGroup 2 }
+
+sdlcPortOperEntry OBJECT-TYPE
+ SYNTAX SdlcPortOperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Currently set parameters for a specific SDLC
+ port."
+ INDEX { ifIndex }
+ ::= { sdlcPortOperTable 1 }
+
+SdlcPortOperEntry ::= SEQUENCE
+{
+ sdlcPortOperName DisplayString,
+ sdlcPortOperRole INTEGER,
+ sdlcPortOperType INTEGER,
+ sdlcPortOperTopology INTEGER,
+ sdlcPortOperISTATUS INTEGER,
+ sdlcPortOperACTIVTO TimeInterval,
+ sdlcPortOperPAUSE TimeInterval,
+ sdlcPortOperSlowPollMethod INTEGER,
+ sdlcPortOperSERVLIM Integer32,
+ sdlcPortOperSlowPollTimer TimeInterval,
+ sdlcPortOperLastModifyTime TimeTicks,
+ sdlcPortOperLastFailTime TimeTicks,
+ sdlcPortOperLastFailCause INTEGER
+}
+
+sdlcPortOperName OBJECT-TYPE
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 14]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ SYNTAX DisplayString (SIZE (1..8))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An octet string that describes the physical
+ port to which this interface is currently
+ attached. It has implementation-specific
+ significance."
+ ::= { sdlcPortOperEntry 1 }
+
+sdlcPortOperRole OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ primary(1),
+ secondary(2),
+ undefined(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the role that the link
+ station has assumed on this connection.
+
+ Even though this is defined as a port object,
+ it is a link station attribute in the sense
+ that a role is per link station. However, it
+ is not possible to vary link station roles on a
+ particular port. For example, if an SDLC port
+ is configured to primary, all link stations on
+ that port must be primary.
+
+ The value of sdlcPortOperRole is undefined(3)
+ whenever the link station role has not yet been
+ established by the mode setting command."
+ ::= { sdlcPortOperEntry 2 }
+
+sdlcPortOperType OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ leased(1),
+ switched(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter defines whether the SDLC port
+ is currently operating as though connected to a
+ leased or switched line."
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 15]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ ::= { sdlcPortOperEntry 3 }
+
+sdlcPortOperTopology OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ pointToPoint(1),
+ multipoint(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter defines whether the SDLC port is
+ currently operating in a point-to-point or
+ multipoint topology."
+ ::= { sdlcPortOperEntry 4 }
+
+sdlcPortOperISTATUS OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inactive(1),
+ active(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter describes the initial value of
+ the administrative status, ifAdminStatus, of
+ this SDLC port at last port start-up."
+ ::= { sdlcPortOperEntry 5 }
+
+
+sdlcPortOperACTIVTO OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This parameter defines the period of time (in
+ 100ths of a second) that the port will allow a
+ switched line to remain inactive before
+ disconnecting. A switched line is considered
+ to be inactive if there are no I-Frames being
+ transferred.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, ACTIVTO. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP ACTIVTO is
+ represented in seconds.
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 16]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ A value of zero indicates no timeout."
+ ::= { sdlcPortOperEntry 6 }
+
+sdlcPortOperPAUSE OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the current minimum
+ elapsed time (in 1/100ths of a second) between
+ any two traversals of the poll list for a
+ primary SDLC port.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, PAUSE. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP PAUSE is
+ represented in 1/10ths of a second.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortAdminRole == primary "
+ ::= { sdlcPortOperEntry 7 }
+
+sdlcPortOperSlowPollMethod OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ servlim(1),
+ pollpause(2),
+ other(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object defines the exact method that is in
+ effect for periodically polling failed secondary
+ link station addresses.
+
+ If sdlcPortOperSlowPollMethod == servlim, then
+ sdlcPortOperSERVLIM defines the actual polling
+ characteristics.
+
+ If sdlcPortOperSlowPollMethod == pollpause,
+ then sdlcPortOperSlowPollTimer defines the
+ actual polling characteristics.
+
+ If sdlcPortOperSlowPollMethod == other, then
+ the polling characteristics are modeled in
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 17]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ vendor-specific objects.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortOperRole == primary
+ and
+ sdlcPortOperTopology == multipoint "
+ ::= { sdlcPortOperEntry 8 }
+
+sdlcPortOperSERVLIM OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the number of times the
+ active poll list is currently being traversed
+ before polling a station on the slow poll list
+ for a primary, multipoint SDLC port.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortOperRole == primary
+ and
+ sdlcPortOperTopology == multipoint "
+ ::= { sdlcPortOperEntry 9 }
+
+sdlcPortOperSlowPollTimer OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the elapsed time (in
+ 1/100ths of a second) between polls for failed
+ secondary link station addresses.
+
+ This object only has meaning for SDLC ports
+ where
+ sdlcPortOperRole == primary
+ and
+ sdlcPortOperTopology == multipoint "
+ ::= { sdlcPortOperEntry 10 }
+
+sdlcPortOperLastModifyTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the value of sysUpTime
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 18]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ when this port definition was last modified.
+ If the port has not been modified, then this
+ value shall be zero."
+ ::= { sdlcPortOperEntry 11 }
+
+sdlcPortOperLastFailTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the value of sysUpTime
+ when this SDLC port last failed. If the port
+ has not failed, then this value shall be zero."
+ ::= { sdlcPortOperEntry 12 }
+
+sdlcPortOperLastFailCause OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ undefined(1),
+ physical(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This enumerated object describes the cause of
+ the last failure of this SDLC port. If the
+ port has not failed, then this object has a
+ value of undefined(1)."
+ DEFVAL { undefined }
+ ::= { sdlcPortOperEntry 13 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 19]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+-- *************************************************************
+-- * *
+-- * THE SDLC PORT STATISTICS TABLE *
+-- * *
+-- *************************************************************
+
+sdlcPortStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcPortStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry in this table contains statistics
+ for a specific SDLC port."
+ ::= { sdlcPortGroup 3 }
+
+sdlcPortStatsEntry OBJECT-TYPE
+ SYNTAX SdlcPortStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of statistics for an SDLC port."
+ INDEX { ifIndex }
+ ::= { sdlcPortStatsTable 1 }
+
+SdlcPortStatsEntry ::= SEQUENCE
+{
+ sdlcPortStatsPhysicalFailures Counter32,
+ sdlcPortStatsInvalidAddresses Counter32,
+ sdlcPortStatsDwarfFrames Counter32,
+ sdlcPortStatsPollsIn Counter32,
+ sdlcPortStatsPollsOut Counter32,
+ sdlcPortStatsPollRspsIn Counter32,
+ sdlcPortStatsPollRspsOut Counter32,
+ sdlcPortStatsLocalBusies Counter32,
+ sdlcPortStatsRemoteBusies Counter32,
+ sdlcPortStatsIFramesIn Counter32,
+ sdlcPortStatsIFramesOut Counter32,
+ sdlcPortStatsOctetsIn Counter32,
+ sdlcPortStatsOctetsOut Counter32,
+ sdlcPortStatsProtocolErrs Counter32,
+ sdlcPortStatsActivityTOs Counter32,
+ sdlcPortStatsRNRLIMITs Counter32,
+ sdlcPortStatsRetriesExps Counter32,
+ sdlcPortStatsRetransmitsIn Counter32,
+ sdlcPortStatsRetransmitsOut Counter32
+}
+
+sdlcPortStatsPhysicalFailures OBJECT-TYPE
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 20]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of times
+ this port has failed due to its physical media
+ since port startup. At port startup time,
+ this object must be initialized to zero."
+ ::= { sdlcPortStatsEntry 1 }
+
+sdlcPortStatsInvalidAddresses OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ frames received by this port with invalid link
+ station addresses."
+ ::= { sdlcPortStatsEntry 2 }
+
+sdlcPortStatsDwarfFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ frames received by this port which were
+ delivered intact by the physical layer but were
+ too short to be legal.
+
+ Ignoring the frame check sequence (FCS), a
+ frame is considered to be too short if it
+ is less than 2 bytes for sdlcLSOperMODULO of
+ eight, or if it is less than 3 bytes for
+ sdlcLSOperMODULO of onetwentyeight."
+
+ ::= { sdlcPortStatsEntry 3 }
+
+sdlcPortStatsPollsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of polls
+ received by this port since the port was
+ created."
+
+ ::= { sdlcPortStatsEntry 4 }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 21]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcPortStatsPollsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of polls
+ sent by this port since the port was created."
+
+ ::= { sdlcPortStatsEntry 5 }
+
+sdlcPortStatsPollRspsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of poll
+ responses received by this port since the port
+ was created."
+
+ ::= { sdlcPortStatsEntry 6 }
+
+sdlcPortStatsPollRspsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of poll
+ responses sent by this port since the port was
+ created."
+
+ ::= { sdlcPortStatsEntry 7 }
+
+sdlcPortStatsLocalBusies OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the local SDLC link stations on
+ this port have entered a busy state (RNR).
+ This object is initialized to zero when the
+ port is created."
+ ::= { sdlcPortStatsEntry 8 }
+
+sdlcPortStatsRemoteBusies OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 22]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the adjacent (i.e., remote) SDLC
+ link stations on this port have entered a busy
+ state (RNR). This object is initialized to
+ zero when the port is created."
+ ::= { sdlcPortStatsEntry 9 }
+
+sdlcPortStatsIFramesIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ I-Frames that have been received by SDLC link
+ stations on this port. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 10 }
+
+sdlcPortStatsIFramesOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ I-Frames that have been transmitted by SDLC
+ link stations on this port. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 11 }
+
+sdlcPortStatsOctetsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total octets
+ received from adjacent SDLC link stations on
+ this port. This object covers the address,
+ control, and information field of I-Frames
+ only. This object is initialized to zero when
+ the port is created."
+ ::= { sdlcPortStatsEntry 12 }
+
+sdlcPortStatsOctetsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 23]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "This object reflects the total octets
+ transmitted to adjacent SDLC link stations on
+ this port. This object covers the address,
+ control, and information field of I-Frames
+ only. This object is initialized to zero when
+ the port is created."
+ ::= { sdlcPortStatsEntry 13 }
+
+sdlcPortStatsProtocolErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the SDLC link stations on this port
+ have deactivated the link as a result of
+ having received a protocol violation from the
+ adjacent link station. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 14 }
+
+sdlcPortStatsActivityTOs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the SDLC link stations on this port
+ have deactivated the link as a result of no
+ activity on the link. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 15 }
+
+sdlcPortStatsRNRLIMITs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the SDLC link stations on this port
+ have deactivated the link as a result of its
+ RNRLIMIT timer expiring. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 16 }
+
+sdlcPortStatsRetriesExps OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 24]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ times that the SDLC link stations on this port
+ have deactivated the link as a result of a
+ retry sequence being exhausted. This object
+ is initialized to zero when the port is
+ created."
+ ::= { sdlcPortStatsEntry 17 }
+
+sdlcPortStatsRetransmitsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ I-Frames retransmitted by remote link stations
+ for all SDLC link stations on this port. This
+ object is initialized to zero when the port is
+ created."
+ ::= { sdlcPortStatsEntry 18 }
+
+sdlcPortStatsRetransmitsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ I-Frames retransmitted by all local SDLC link
+ stations on this port. This object is
+ initialized to zero when the port is created."
+ ::= { sdlcPortStatsEntry 19 }
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 25]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+--
+-- THE SDLC LINK STATION GROUP
+-- ===========================
+--
+
+-- The following classes of information is modelled for each SDLC link
+-- station:
+--
+-- 1. ADMINISTRATIVE ( read-write)
+-- 2. OPERATIONAL ( read-only)
+-- 3. STATISTICS ( read-only)
+
+-- *************************************************************
+-- * *
+-- * THE SDLC LINK STATION ADMINISTRATIVE TABLE *
+-- * *
+-- *************************************************************
+
+sdlcLSAdminTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcLSAdminEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains objects that can be
+ changed to manage an SDLC link station.
+ Changing one of these parameters may take
+ effect in the operating link immediately or may
+ wait until the link is restarted depending on
+ the details of the implementation.
+
+ The entries in sdlcLSAdminTable can be created
+ either by an agent or a management station. The
+ management station can create an entry in
+ sdlcLSAdminTable by setting the appropriate
+ value in sdlcLSAdminRowStatus.
+
+ Most of the objects in this read-create table
+ have corresponding read-only objects in the
+ sdlcLSOperTable that reflect the current
+ operating value.
+
+ The operating values may be different from
+ these configured values if changed by XID
+ negotiation or if a configured parameter was
+ changed after the link was started."
+ ::= { sdlcLSGroup 1 }
+
+sdlcLSAdminEntry OBJECT-TYPE
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 26]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ SYNTAX SdlcLSAdminEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of configured values for an SDLC link
+ station."
+ INDEX { ifIndex, sdlcLSAddress }
+ ::= { sdlcLSAdminTable 1 }
+
+SdlcLSAdminEntry ::= SEQUENCE
+{
+ sdlcLSAddress INTEGER,
+ sdlcLSAdminName DisplayString,
+ sdlcLSAdminState INTEGER,
+ sdlcLSAdminISTATUS INTEGER,
+ sdlcLSAdminMAXDATASend Integer32,
+ sdlcLSAdminMAXDATARcv Integer32,
+ sdlcLSAdminREPLYTO TimeInterval,
+ sdlcLSAdminMAXIN INTEGER,
+ sdlcLSAdminMAXOUT INTEGER,
+ sdlcLSAdminMODULO INTEGER,
+ sdlcLSAdminRETRIESm INTEGER,
+ sdlcLSAdminRETRIESt TimeInterval,
+ sdlcLSAdminRETRIESn Integer32,
+ sdlcLSAdminRNRLIMIT TimeInterval,
+ sdlcLSAdminDATMODE INTEGER,
+ sdlcLSAdminGPoll INTEGER,
+ sdlcLSAdminSimRim INTEGER,
+ sdlcLSAdminXmitRcvCap INTEGER,
+ sdlcLSAdminRowStatus RowStatus
+}
+
+sdlcLSAddress OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This value is the poll address of the
+ secondary link station for this SDLC link. It
+ uniquely identifies the SDLC link station
+ within a single SDLC port."
+ ::= { sdlcLSAdminEntry 1 }
+
+sdlcLSAdminName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..10))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 27]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "An octet string that defines the local name of
+ the SDLC link station. This field may be sent
+ in the XID3 control vector 0x0E, type 0xF7."
+ ::= { sdlcLSAdminEntry 2 }
+
+sdlcLSAdminState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inactive(1),
+ active(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the desired state of the
+ SDLC station. The managed system shall attempt
+ to keep the operational state, sdlcLSOperState,
+ consistent with this value."
+ DEFVAL { active }
+ ::= { sdlcLSAdminEntry 3 }
+
+sdlcLSAdminISTATUS OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ inactive(1),
+ active(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This parameter controls the desired state,
+ sdlcLSAdminState, of the SDLC link station at
+ link station start-up."
+ DEFVAL { active }
+ ::= { sdlcLSAdminEntry 4 }
+
+sdlcLSAdminMAXDATASend OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object contains the maximum PDU size that
+ the local link station thinks it can send to
+ the adjacent link station before having
+ received any XID from the ALS. After the
+ maximum PDU size that the ALS can receive is
+ known (via XID exchange) that value is
+ reflected in sdlcLSOperMAXDATASend and takes
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 28]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ precedence over this object.
+
+ This value includes the Transmission Header
+ (TH) and the Request Header (RH)."
+ ::= { sdlcLSAdminEntry 5 }
+
+sdlcLSAdminMAXDATARcv OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object contains the maximum PDU size that
+ the local link station can receive from the
+ adjacent link station. This value is sent in
+ the XID to the ALS.
+
+ This value includes the Transmission Header
+ (TH) and the Request Header (RH)."
+ ::= { sdlcLSAdminEntry 6 }
+
+sdlcLSAdminREPLYTO OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the reply timeout (in
+ 1/100ths of a second) for an SDLC link
+ station. If the link station does not receive
+ a response to a poll or message before the
+ specified time expires then the appropriate
+ error recovery shall be initiated.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, REPLYTO. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP REPLYTO is
+ represented in 1/10ths of a second.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value, sdlcLSOperREPLYTO,
+ until the link station is cycled inactive.
+
+ This object only has meaning for SDLC ports
+ where sdlcPortAdminRole == primary "
+ DEFVAL { 100 }
+ ::= { sdlcLSAdminEntry 7 }
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 29]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSAdminMAXIN OBJECT-TYPE
+ SYNTAX INTEGER (1..127)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the maximum number of
+ unacknowledged I-frames which an SDLC link
+ station may receive. This should range from 1
+ to (sdlcLSAdminMODULO - 1). This value is sent
+ in the XID to the ALS.
+
+ A write operation to this administered value
+ will not change the operational value,
+ sdlcLSOperMAXIN, until the link station is
+ cycled inactive."
+ DEFVAL { 7 }
+ ::= { sdlcLSAdminEntry 8 }
+
+sdlcLSAdminMAXOUT OBJECT-TYPE
+ SYNTAX INTEGER (1..127)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the maximum number of
+ consecutive unacknowledged I-frames which an
+ SDLC link station shall send without an
+ acknowledgement. This shall range from 1 to
+ (sdlcLSAdminMODULO - 1).
+
+ For link stations on switched SDLC lines,
+ certain implementions may choose to override
+ this administered value with the value
+ received in the XID exchange.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value,
+ sdlcLSOperMAXOUT, until the link station is
+ cycled inactive.
+
+ An implementation can support only modulo 8,
+ only modulo 128, or both."
+ DEFVAL { 1 }
+ ::= { sdlcLSAdminEntry 9 }
+
+sdlcLSAdminMODULO OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 30]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ eight(8),
+ onetwentyeight(128)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the modulus for an SDLC
+ link station. This modulus determines the size
+ of the rotating acknowledgement window used the
+ SDLC link station pair.
+
+ A write operation to this administered value
+ will not change the operational value,
+ sdlcLSOperMODULO, until the link station is
+ cycled inactive.
+
+ An implementation can support only modulo 8,
+ only modulo 128, or both."
+ DEFVAL { eight }
+ ::= { sdlcLSAdminEntry 10 }
+
+sdlcLSAdminRETRIESm OBJECT-TYPE
+ SYNTAX INTEGER (0..128)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls number of retries in a
+ retry sequence for the local SDLC link
+ station. A retry sequence is a series of
+ retransmitted frames ( data or control) for
+ which no positive acknowledgement is received.
+
+ The number of times that the retry sequence is
+ to be repeated is controlled by the object:
+ sdlcLSAdminRETRIESn. The interval between retry
+ sequences is controlled by the object:
+ sdlcLSAdminRETRIESt.
+
+ A value of zero indicates no retries. If the
+ value of sdlcLSAdminRETRIESm is zero, then the
+ values of sdlcLSAdminRETRIESt and
+ sdlcLSAdminRETRIESn should also be zero.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value,
+ sdlcLSOperRETRIESm, until the link station is
+ cycled inactive."
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 31]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ DEFVAL { 15 }
+ ::= { sdlcLSAdminEntry 11 }
+
+sdlcLSAdminRETRIESt OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the interval (in 1/100ths
+ of a second) between retry sequences for the
+ local SDLC link station if multiple retry
+ sequences are specified . A retry sequence is
+ a series of retransmitted frames ( data or
+ control) for which no positive acknowledgement
+ is received.
+
+ The number of repeated retries sequences is
+ controlled by the object: sdlcLSAdminRETRIESn.
+ The retries per sequence is controlled by the
+ object: sdlcLSAdminRETRIESm.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, RETRIESt. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP RETRIESt is
+ represented in seconds.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value,
+ sdlcLSOperRETRIESt, until the link station is
+ cycled inactive."
+ DEFVAL { 0 }
+ ::= { sdlcLSAdminEntry 12 }
+
+sdlcLSAdminRETRIESn OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the number of times that
+ a retry sequence is repeated for the local SDLC
+ link station. A retry sequence is a series of
+ retransmitted frames ( data or control) for
+ which no positive acknowledgement is received.
+
+ The interval between retry sequences is
+ controlled by the object: sdlcLSAdminRETRIESn.
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 32]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ The retries per sequence is controlled by the
+ object: sdlcLSAdminRETRIESm.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value,
+ sdlcLSOperRETRIESn, until the link station is
+ cycled inactive."
+ DEFVAL { 0 }
+ ::= { sdlcLSAdminEntry 13 }
+
+sdlcLSAdminRNRLIMIT OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the length of time (in
+ 1/100ths of a second) that an SDLC link station
+ will allow its adjacent link station to remain
+ in a busy (RNR) state before declaring it
+ inoperative.
+
+ A value of sdlcLSAdminRNRLIMIT == 0 means there
+ is no limit.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, RNRLIMIT. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP RNRLIMIT is
+ represented in minutes.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value,
+ sdlcLSOperRNRLIMIT, until the link station is
+ cycled inactive."
+ DEFVAL { 18000 }
+ ::= { sdlcLSAdminEntry 14 }
+
+sdlcLSAdminDATMODE OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ half(1),
+ full(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 33]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "This object controls whether communications
+ mode with the adjacent link station is
+ two-way-alternate (half) or two-way-simultaneous
+ (full).
+
+ A write operation to this administered value
+ will not change the operational value,
+ sdlcLSOperDATMODE, until the link station is
+ cycled inactive."
+ DEFVAL { half }
+ ::= { sdlcLSAdminEntry 15 }
+
+sdlcLSAdminGPoll OBJECT-TYPE
+ SYNTAX INTEGER (0..254)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object describes the group poll address
+ for this link station instance. If group poll
+ is not in effect for this link station
+ instance, the value for sdlcLSAdminGPoll should
+ be zero.
+
+ Depending on the implementation, a write
+ operation to this administered value may not
+ change the operational value, sdlcLSOperGPoll,
+ until the link station is cycled inactive."
+ ::= { sdlcLSAdminEntry 16 }
+
+sdlcLSAdminSimRim OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ no(1),
+ yes(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the support for
+ transmission and receipt of SIM and RIM control
+ frames for this link station. The value of
+ this object controls the setting of the
+ transmit-receive capability sent in the XID
+ field."
+ DEFVAL { no }
+ ::= { sdlcLSAdminEntry 17 }
+
+sdlcLSAdminXmitRcvCap OBJECT-TYPE
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 34]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ SYNTAX INTEGER
+ {
+ twa(1),
+ tws(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the transmit-receive
+ capabilities for this SDLC link station. The
+ value of this object establishes the value of
+ the transmit-receive capability indicator sent
+ in the XID image to the adjacent link station."
+ DEFVAL { twa }
+ ::= { sdlcLSAdminEntry 18 }
+
+sdlcLSAdminRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object is used by a management station to
+ create or delete the row entry in
+ sdlcLSAdminTable following the RowStatus
+ textual convention.
+
+ Upon successful creation of the row, an agent
+ automatically creates a corresponding entry in
+ the sdlcLSOperTable with sdlcLSOperState equal
+ to 'discontacted (1)'."
+ ::= { sdlcLSAdminEntry 19 }
+
+-- *************************************************************
+-- * *
+-- * THE SDLC LINK STATION OPERATIONAL TABLE *
+-- * *
+-- *************************************************************
+
+sdlcLSOperTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcLSOperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains current SDLC link
+ parameters. Many of these objects have
+ corresponding objects in the
+ sdlcLSAdminTable."
+ ::= { sdlcLSGroup 2 }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 35]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSOperEntry OBJECT-TYPE
+ SYNTAX SdlcLSOperEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of status and control values for an
+ SDLC link station."
+ INDEX { ifIndex, sdlcLSAddress }
+ ::= { sdlcLSOperTable 1 }
+
+SdlcLSOperEntry ::= SEQUENCE
+{
+ sdlcLSOperName DisplayString,
+ sdlcLSOperRole INTEGER,
+ sdlcLSOperState INTEGER,
+ sdlcLSOperMAXDATASend Integer32,
+ sdlcLSOperREPLYTO TimeInterval,
+ sdlcLSOperMAXIN INTEGER,
+ sdlcLSOperMAXOUT INTEGER,
+ sdlcLSOperMODULO INTEGER,
+ sdlcLSOperRETRIESm INTEGER,
+ sdlcLSOperRETRIESt TimeInterval,
+ sdlcLSOperRETRIESn INTEGER,
+ sdlcLSOperRNRLIMIT TimeInterval,
+ sdlcLSOperDATMODE INTEGER,
+ sdlcLSOperLastModifyTime TimeTicks,
+ sdlcLSOperLastFailTime TimeTicks,
+ sdlcLSOperLastFailCause INTEGER,
+ sdlcLSOperLastFailCtrlIn OCTET STRING,
+ sdlcLSOperLastFailCtrlOut OCTET STRING,
+ sdlcLSOperLastFailFRMRInfo OCTET STRING,
+ sdlcLSOperLastFailREPLYTOs Counter32,
+ sdlcLSOperEcho INTEGER,
+ sdlcLSOperGPoll INTEGER,
+ sdlcLSOperSimRim INTEGER,
+ sdlcLSOperXmitRcvCap INTEGER
+}
+
+sdlcLSOperName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (1..10))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An octet string that defines the name of the
+ remote SDLC link station. This field is
+ received in the XID3 control vector 0x0E, type
+ 0xF7."
+ ::= { sdlcLSOperEntry 1 }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 36]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSOperRole OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ primary(1),
+ secondary(2),
+ undefined(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current role that the
+ link station is assuming.
+
+ The value of sdlcLSOperRole is undefined(3)
+ whenever the link station role has not yet been
+ established by the mode setting command."
+ ::= { sdlcLSOperEntry 2 }
+
+sdlcLSOperState OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ discontacted(1),
+ contactPending(2),
+ contacted(3),
+ discontactPending(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the operational state of
+ the SDLC link station. The managed system
+ shall attempt to keep this value consistent
+ with the administered state, sdlcLSAdminState"
+ ::= { sdlcLSOperEntry 3 }
+
+sdlcLSOperMAXDATASend OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object contains the actual maximum PDU
+ size that the local link station can send to
+ the adjacent link station. This object is
+ established from the value received in the XID
+ from the adjacent link station. If no XID
+ is received, then this value is implementation
+ dependent (for instance, it could be the value
+ of sdlcLSAdminMAXDATASend).
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 37]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ This value includes the Transmission Header
+ (TH) and the Request Header (RH)."
+ ::= { sdlcLSOperEntry 4 }
+
+sdlcLSOperREPLYTO OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current reply timeout
+ (in 1/100ths of a second) for an SDLC link
+ station. If the link station does not receive
+ a response to a poll or message before the
+ specified time expires then the appropriate
+ error recovery shall be initiated.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, REPLYTO. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP REPLYTO is
+ represented in 1/10ths of a second.
+
+ This object only has meaning for SDLC ports
+ where sdlcPortOperRole == primary "
+ ::= { sdlcLSOperEntry 5 }
+
+sdlcLSOperMAXIN OBJECT-TYPE
+ SYNTAX INTEGER (1..127)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current maximum
+ number of unacknowledged I-frames which an SDLC
+ link station may receive. This shall range
+ from 1 to (sdlcLSOperMODULO - 1)."
+ ::= { sdlcLSOperEntry 6 }
+
+sdlcLSOperMAXOUT OBJECT-TYPE
+ SYNTAX INTEGER (1..127)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object controls the maximum number of
+ consecutive unacknowledged I-frames which an
+ SDLC link station shall send without an
+ acknowledgement. This shall range from 1 to
+ (sdlcLSAdminMODULO - 1).
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 38]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ This value may controlled by the administered
+ MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value
+ received during the XID exchange."
+ ::= { sdlcLSOperEntry 7 }
+
+sdlcLSOperMODULO OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ eight(8),
+ onetwentyeight(128)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current modulus for
+ an SDLC link station. This modulus determines
+ the size of rotating acknowledgement window
+ used by the SDLC link station pair."
+ DEFVAL { eight }
+ ::= { sdlcLSOperEntry 8 }
+
+sdlcLSOperRETRIESm OBJECT-TYPE
+ SYNTAX INTEGER (0..128)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object controls number of retries in a
+ retry sequence for an SDLC link station. A
+ retry sequence is a series of retransmitted
+ frames ( data or control) for which no positive
+ acknowledgement is received.
+
+ The current number of times that the retry
+ sequence is to be repeated is reflected by the
+ object: sdlcLSOperRETRIESn. The current
+ interval between retry sequences is reflected
+ by the object: sdlcLSOperRETRIESt."
+ ::= { sdlcLSOperEntry 9 }
+
+sdlcLSOperRETRIESt OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current interval (in
+ 1/100ths of a second) between retry sequences
+ for an SDLC link station if multiple retry
+ sequences are specified. A retry sequence is a
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 39]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ series of retransmitted frames ( data or
+ control) for which no positive acknowledgement
+ is received.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, RETRIESt. Please
+ note that the value of this object represents
+ 1/100ths of a second while the NCP RETRIESt is
+ represented in seconds.
+
+ The current number of repeated retries
+ sequences is reflected by the object:
+ sdlcLSOperRETRIESn. The current retries per
+ sequence is reflected by the object:
+ sdlcLSOperRETRIESm."
+ ::= { sdlcLSOperEntry 10 }
+
+sdlcLSOperRETRIESn OBJECT-TYPE
+ SYNTAX INTEGER (0..127)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current number of
+ times that a retry sequence is repeated for an
+ SDLC link station. A retry sequence is a
+ series of retransmitted frames ( data or
+ control) for which no positive acknowledgement
+ is received.
+
+ The current interval between retry sequences is
+ reflected by the object: sdlcLSOperRETRIESn.
+ The current retries per sequence is reflected
+ by the object: sdlcLSOperRETRIESm."
+ ::= { sdlcLSOperEntry 11 }
+
+sdlcLSOperRNRLIMIT OBJECT-TYPE
+ SYNTAX TimeInterval
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the current length of
+ time (in 1/100ths of a second) that an SDLC
+ link station will allow its adjacent link
+ station to remain in a busy (RNR) state before
+ declaring it inoperative.
+
+ The object descriptor contains the name of an
+ NCP configuration parameter, RNRLIMIT. Please
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 40]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ note that the value of this object represents
+ 1/100ths of a second while the NCP RNRLIMIT is
+ represented in minutes.
+
+ A value of sdlcLSOperRNRLIMIT == 0 means there
+ is no limit."
+ ::= { sdlcLSOperEntry 12 }
+
+sdlcLSOperDATMODE OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ half(1),
+ full(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects whether the current
+ communications mode with the adjacent link
+ station is two-way-alternate (half) or
+ two-way-simultaneous (full)."
+ ::= { sdlcLSOperEntry 13 }
+
+sdlcLSOperLastModifyTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the value of sysUpTime
+ when this link station definition was last
+ modified. If the link station has not been
+ modified, then this value shall be zero."
+ ::= { sdlcLSOperEntry 14 }
+
+sdlcLSOperLastFailTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the value of sysUpTime
+ when this SDLC link station last failed. If
+ the link station has not failed, then this
+ value shall be zero."
+ ::= { sdlcLSOperEntry 15 }
+
+sdlcLSOperLastFailCause OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 41]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ undefined(1),
+ rxFRMR(2),
+ txFRMR(3),
+ noResponse(4),
+ protocolErr(5),
+ noActivity(6),
+ rnrLimit(7),
+ retriesExpired(8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This enumerated object reflects the cause of
+ the last failure of this SDLC link station. If
+ the link station has not failed, then this
+ object will have a value of undefined(1)."
+ DEFVAL { undefined }
+ ::= { sdlcLSOperEntry 16 }
+
+sdlcLSOperLastFailCtrlIn OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the last control octet or
+ octets (depending on modulus) received by this
+ SDLC link station at the time of the last
+ failure. If the link station has not failed,
+ then this value has no meaning."
+ ::= { sdlcLSOperEntry 17 }
+
+sdlcLSOperLastFailCtrlOut OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(1..2))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the last control octet or
+ octets (depending on modulus) sent by this SDLC
+ link station at the time of the last failure.
+ If the link station has not failed, then this
+ value has no meaning."
+ ::= { sdlcLSOperEntry 18 }
+
+sdlcLSOperLastFailFRMRInfo OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE(3))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 42]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "This object reflects the information field of
+ the FRMR frame if the last failure for this
+ SDLC link station was as a result of an invalid
+ frame. Otherwise, this field has no meaning."
+ ::= { sdlcLSOperEntry 19 }
+
+sdlcLSOperLastFailREPLYTOs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the number of times that
+ the REPLYTO timer had expired for an SDLC link
+ station at the time of the last failure. If the
+ link station has not failed, then this value
+ has no meaning."
+ ::= { sdlcLSOperEntry 20 }
+
+sdlcLSOperEcho OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ no(1),
+ yes(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies whether the echo bit is
+ in effect for this particular link station."
+ DEFVAL { no }
+ ::= { sdlcLSOperEntry 21 }
+
+sdlcLSOperGPoll OBJECT-TYPE
+ SYNTAX INTEGER (0..254)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object describes the group poll address
+ in effect for this link station instance."
+ DEFVAL { 0 }
+ ::= { sdlcLSOperEntry 22 }
+
+sdlcLSOperSimRim OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ no(1),
+ yes(2)
+ }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 43]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the support for
+ transmission and receipt of SIM and RIM control
+ frames for the adjacent link station. The
+ value of this object is set from the XID field
+ received from the adjacent link station."
+ DEFVAL { no }
+ ::= { sdlcLSOperEntry 23 }
+
+sdlcLSOperXmitRcvCap OBJECT-TYPE
+ SYNTAX INTEGER
+ {
+ twa(1),
+ tws(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the transmit-receive
+ capabilities for the adjacent SDLC link
+ station. The value of this object is the value
+ of the transmit-receive capability indicator
+ received in the XID image from the adjacent
+ link station."
+ DEFVAL { twa }
+ ::= { sdlcLSOperEntry 24 }
+
+
+-- *************************************************************
+-- * *
+-- * THE SDLC LINK STATION STATISTICS TABLE *
+-- * *
+-- *************************************************************
+
+sdlcLSStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SdlcLSStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Each entry in this table contains statistics
+ for a specific SDLC link station."
+ ::= { sdlcLSGroup 3 }
+
+sdlcLSStatsEntry OBJECT-TYPE
+ SYNTAX SdlcLSStatsEntry
+ MAX-ACCESS not-accessible
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 44]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ STATUS current
+ DESCRIPTION
+ "A list of statistics for an SDLC link station."
+ INDEX { ifIndex, sdlcLSAddress }
+ ::= { sdlcLSStatsTable 1 }
+
+SdlcLSStatsEntry ::= SEQUENCE
+{
+ sdlcLSStatsBLUsIn Counter32,
+ sdlcLSStatsBLUsOut Counter32,
+ sdlcLSStatsOctetsIn Counter32,
+ sdlcLSStatsOctetsOut Counter32,
+ sdlcLSStatsPollsIn Counter32,
+ sdlcLSStatsPollsOut Counter32,
+ sdlcLSStatsPollRspsIn Counter32,
+ sdlcLSStatsPollRspsOut Counter32,
+ sdlcLSStatsLocalBusies Counter32,
+ sdlcLSStatsRemoteBusies Counter32,
+ sdlcLSStatsIFramesIn Counter32,
+ sdlcLSStatsIFramesOut Counter32,
+ sdlcLSStatsUIFramesIn Counter32,
+ sdlcLSStatsUIFramesOut Counter32,
+ sdlcLSStatsXIDsIn Counter32,
+ sdlcLSStatsXIDsOut Counter32,
+ sdlcLSStatsTESTsIn Counter32,
+ sdlcLSStatsTESTsOut Counter32,
+ sdlcLSStatsREJsIn Counter32,
+ sdlcLSStatsREJsOut Counter32,
+ sdlcLSStatsFRMRsIn Counter32,
+ sdlcLSStatsFRMRsOut Counter32,
+ sdlcLSStatsSIMsIn Counter32,
+ sdlcLSStatsSIMsOut Counter32,
+ sdlcLSStatsRIMsIn Counter32,
+ sdlcLSStatsRIMsOut Counter32,
+ sdlcLSStatsDISCIn Counter32,
+ sdlcLSStatsDISCOut Counter32,
+ sdlcLSStatsUAIn Counter32,
+ sdlcLSStatsUAOut Counter32,
+ sdlcLSStatsDMIn Counter32,
+ sdlcLSStatsDMOut Counter32,
+ sdlcLSStatsSNRMIn Counter32,
+ sdlcLSStatsSNRMOut Counter32,
+ sdlcLSStatsProtocolErrs Counter32,
+ sdlcLSStatsActivityTOs Counter32,
+ sdlcLSStatsRNRLIMITs Counter32,
+ sdlcLSStatsRetriesExps Counter32,
+ sdlcLSStatsRetransmitsIn Counter32,
+ sdlcLSStatsRetransmitsOut Counter32
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 45]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+}
+
+sdlcLSStatsBLUsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total basic link
+ units (BLUs; frames) received from an adjacent
+ SDLC link station since link station startup.
+ At link station startup time, this object must
+ be initialized to zero."
+ ::= { sdlcLSStatsEntry 1 }
+
+sdlcLSStatsBLUsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total basic link
+ units (BLUs; frames), transmitted to an
+ adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 2 }
+
+sdlcLSStatsOctetsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total octets received
+ from an adjacent SDLC link station since link
+ station startup. This object covers the
+ address, control, and information field of
+ I-Frames only. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 3 }
+
+sdlcLSStatsOctetsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total octets
+ transmitted to an adjacent SDLC link station
+ since link station startup. This object covers
+ the address, control, and information field of
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 46]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ I-Frames only. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 4 }
+
+sdlcLSStatsPollsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total polls received
+ from an adjacent SDLC link station since link
+ station startup. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 5 }
+
+sdlcLSStatsPollsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total polls sent to
+ an adjacent SDLC link station since link
+ station startup. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 6 }
+
+sdlcLSStatsPollRspsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of poll
+ responses sent to the adjacent SDLC link
+ station since link station startup. This value
+ includes I-frames that are sent in response to
+ a poll.
+
+ At link station startup time, this object must
+ be initialized to zero."
+ ::= { sdlcLSStatsEntry 7 }
+
+sdlcLSStatsPollRspsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of poll
+ responses received from the adjacent SDLC link
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 47]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ station since station startup. This value
+ includes I-frames that are received in response
+ to a poll.
+
+ At link station startup time, this object must
+ be initialized to zero."
+ ::= { sdlcLSStatsEntry 8 }
+
+sdlcLSStatsLocalBusies OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of times
+ that the local SDLC link station has entered a
+ busy state (RNR) since link station startup.
+ At link station startup time, this object must
+ be initialized to zero."
+ ::= { sdlcLSStatsEntry 9 }
+
+sdlcLSStatsRemoteBusies OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of times
+ that an adjacent ( remote) SDLC link station
+ has entered a busy state (RNR) since link
+ station startup. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 10 }
+
+sdlcLSStatsIFramesIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total I-frames
+ received from an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 11 }
+
+sdlcLSStatsIFramesOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 48]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ DESCRIPTION
+ "This object reflects the total I-frames
+ transmitted to an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 12 }
+
+sdlcLSStatsUIFramesIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total UI-frames
+ received from an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 13 }
+
+sdlcLSStatsUIFramesOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total UI-frames
+ transmitted to an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 14 }
+
+sdlcLSStatsXIDsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total XID frames
+ received from an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 15 }
+
+sdlcLSStatsXIDsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total XID frames
+ transmitted to an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 16 }
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 49]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSStatsTESTsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total TEST frames,
+ commands or responses, received from an
+ adjacent SDLC link station since link station
+ startup."
+ ::= { sdlcLSStatsEntry 17 }
+
+sdlcLSStatsTESTsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total TEST frames,
+ commands or responses, transmitted to an
+ adjacent SDLC link station since link station
+ startup."
+ ::= { sdlcLSStatsEntry 18 }
+
+sdlcLSStatsREJsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total REJ frames
+ received from an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 19 }
+
+sdlcLSStatsREJsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total REJ frames
+ transmitted to an adjacent SDLC link station
+ since link station startup."
+ ::= { sdlcLSStatsEntry 20 }
+
+sdlcLSStatsFRMRsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total frame reject
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 50]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ (FRMR) frames received from an adjacent SDLC
+ link station since link station startup."
+ ::= { sdlcLSStatsEntry 21 }
+
+sdlcLSStatsFRMRsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total frame reject
+ (FRMR) frames transmitted to an adjacent SDLC
+ link station since link station startup."
+ ::= { sdlcLSStatsEntry 22 }
+
+sdlcLSStatsSIMsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total set
+ initialization mode (SIM) frames received from
+ an adjacent SDLC link station since link station
+ startup."
+ ::= { sdlcLSStatsEntry 23 }
+
+sdlcLSStatsSIMsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total set
+ initialization mode (SIM) frames transmitted to
+ an adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 24 }
+
+sdlcLSStatsRIMsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total request
+ initialization mode (RIM) frames received from
+ an adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 25 }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 51]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSStatsRIMsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total request
+ initialization mode (RIM) frames transmitted to
+ an adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 26 }
+
+sdlcLSStatsDISCIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ disconnect (DISC) requests received from an
+ adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 27 }
+
+sdlcLSStatsDISCOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ disconnect (DISC) requests transmited to an
+ adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 28 }
+
+sdlcLSStatsUAIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ unnumbered acknowledgements (UA) requests
+ received from an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 29 }
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 52]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+sdlcLSStatsUAOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ unnumbered acknowledgements (UA) requests
+ transmited to an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 30 }
+
+sdlcLSStatsDMIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ disconnect mode (DM) requests received from an
+ adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 31 }
+
+sdlcLSStatsDMOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ disconnect mode (DM) requests transmited to an
+ adjacent SDLC link station since link station
+ startup. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 32 }
+
+sdlcLSStatsSNRMIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ set normal response mode (SNRM/SNRME) requests
+ received from an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 53]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ ::= { sdlcLSStatsEntry 33 }
+
+sdlcLSStatsSNRMOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ set normal response mode (SNRM/SNRME) requests
+ transmited to an adjacent SDLC link station
+ since link station startup. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 34 }
+
+sdlcLSStatsProtocolErrs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total occurrences,
+ since link station startup, where this SDLC
+ link station has inactivated the link as a
+ result of receiving a frame from its adjacent
+ link station which was in violation of the
+ protocol. At link station startup time, this
+ object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 35 }
+
+sdlcLSStatsActivityTOs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total occurrences,
+ since startup, where this SDLC link station has
+ inactivated the link as a result of no activity
+ on the link. At link station startup time,
+ this object must be initialized to zero."
+ ::= { sdlcLSStatsEntry 36 }
+
+sdlcLSStatsRNRLIMITs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total occurrences,
+ since startup, where this SDLC link station has
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 54]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ inactivated the link as a result of its
+ RNRLIMIT timer expiring. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 37 }
+
+sdlcLSStatsRetriesExps OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total occurrences,
+ since startup, where this SDLC link station has
+ inactivated the link as a result of a retry
+ sequence being exhausted. At link station
+ startup time, this object must be initialized
+ to zero."
+ ::= { sdlcLSStatsEntry 38 }
+
+sdlcLSStatsRetransmitsIn OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object reflects the total number of
+ information frames retransmitted by the remote
+ link station because the N(s) received from
+ that link station indicated that one or more
+ information frames sent by that station were
+ lost. This event causes the first missing
+ information frame of a window and all
+ subsequent information frames to be
+ retransmitted. At link station startup time,
+ this object must be initialized to zero.
+
+ Management: If the value of
+ sdlcLSStatsRetransmitsIn grows over time, then
+ the quality of the serial line is in
+ question. You might want to look at
+ decreasing the value for
+ sdlcLSAdminMAXDATASend to compensate for the
+ lower quality line."
+ ::= { sdlcLSStatsEntry 39 }
+
+sdlcLSStatsRetransmitsOut OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 55]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ DESCRIPTION
+ "This object reflects the total number of
+ information frames retransmitted to a remote
+ link station because the N(r) received from
+ that link station indicated that one or more
+ information frames sent to that station were
+ lost. This event causes the first missing
+ information frame of a window and all
+ subsequent information frames to be
+ retransmitted. At link station startup time,
+ this object must be initialized to zero.
+
+ Management: If the value of
+ sdlcLSStatsRetransmitsOut grows over time,
+ then the quality of the serial line is in
+ question. You might want to look at
+ decreasing the value for sdlcLSAdminMAXDATASend
+ to compensate for the lower quality line."
+ ::= { sdlcLSStatsEntry 40 }
+
+--
+-- TRAP DEFINITIONS
+--
+
+--
+-- Notifications
+--
+
+sdlcTraps OBJECT IDENTIFIER ::= { sdlc 3 }
+
+sdlcPortStatusChange NOTIFICATION-TYPE
+ OBJECTS { ifIndex,
+ ifAdminStatus,
+ ifOperStatus,
+ sdlcPortOperLastFailTime,
+ sdlcPortOperLastFailCause
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the state of an SDLC
+ port has transitioned to active or inactive."
+ ::= { sdlcTraps 1 }
+
+sdlcLSStatusChange NOTIFICATION-TYPE
+ OBJECTS { ifIndex,
+ sdlcLSAddress,
+ sdlcLSOperState,
+ sdlcLSAdminState,
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 56]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ sdlcLSOperLastFailTime,
+ sdlcLSOperLastFailCause,
+ sdlcLSOperLastFailFRMRInfo,
+ sdlcLSOperLastFailCtrlIn,
+ sdlcLSOperLastFailCtrlOut,
+ sdlcLSOperLastFailREPLYTOs
+ }
+ STATUS current
+ DESCRIPTION
+ "This trap indicates that the state of an SDLC
+ link station has transitioned to contacted or
+ discontacted."
+ ::= { sdlcTraps 2 }
+
+
+--
+-- Conformance Information
+--
+
+sdlcConformance OBJECT IDENTIFIER ::= { sdlc 4 }
+
+sdlcCompliances OBJECT IDENTIFIER ::= { sdlcConformance 1 }
+sdlcGroups OBJECT IDENTIFIER ::= { sdlcConformance 2 }
+
+--
+-- Compliance Statements
+--
+
+sdlcCoreCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The core compliance statement for all SDLC
+ nodes."
+ MODULE
+ MANDATORY-GROUPS
+ {
+ sdlcCorePortAdminGroup,
+ sdlcCorePortOperGroup,
+ sdlcCorePortStatsGroup,
+ sdlcCoreLSAdminGroup,
+ sdlcCoreLSOperGroup,
+ sdlcCoreLSStatsGroup
+ }
+
+ OBJECT sdlcPortAdminName
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 57]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ OBJECT sdlcPortAdminRole
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcPortAdminType
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcPortAdminTopology
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcPortAdminISTATUS
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAddress
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminName
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminState
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminISTATUS
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminMAXDATASend
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminMAXDATARcv
+ MIN-ACCESS read-only
+ DESCRIPTION
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 58]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminMAXIN
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminMAXOUT
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminMODULO
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminRETRIESm
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminRETRIESt
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminRETRIESn
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminRNRLIMIT
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminDATMODE
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminGPoll
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminSimRim
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 59]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminRowStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { sdlcCompliances 1 }
+
+sdlcPrimaryCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for all nodes that
+ are performing the role of a Primary link
+ station."
+ MODULE
+ MANDATORY-GROUPS { sdlcPrimaryGroup }
+
+ OBJECT sdlcPortAdminPAUSE
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcLSAdminREPLYTO
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { sdlcCompliances 2 }
+
+sdlcPrimaryMultipointCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for all nodes that
+ are performing the role of a primary link
+ station on a multipoint line."
+ MODULE
+ MANDATORY-GROUPS { sdlcPrimaryMultipointGroup }
+
+ OBJECT sdlcPortAdminSERVLIM
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT sdlcPortAdminSlowPollTimer
+ MIN-ACCESS read-only
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 60]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ DESCRIPTION
+ "Write access is not required."
+
+ ::= { sdlcCompliances 3 }
+
+
+--
+-- Core Conformance Groups for All Link Stations
+--
+
+sdlcCoreGroups OBJECT IDENTIFIER ::= { sdlcGroups 1 }
+
+sdlcCorePortAdminGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcPortAdminName, sdlcPortAdminRole,
+ sdlcPortAdminType, sdlcPortAdminTopology,
+ sdlcPortAdminISTATUS
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortAdminGroup defines objects
+ which are common to the PortAdmin group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 1 }
+
+sdlcCorePortOperGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcPortOperName,
+ sdlcPortOperRole,
+ sdlcPortOperType,
+ sdlcPortOperTopology,
+ sdlcPortOperISTATUS,
+ sdlcPortOperACTIVTO,
+ sdlcPortOperLastFailTime,
+ sdlcPortOperLastFailCause
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortOperGroup defines objects
+ which are common to the PortOper group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 2 }
+
+
+sdlcCorePortStatsGroup OBJECT-GROUP
+ OBJECTS
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 61]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ {
+ sdlcPortStatsPhysicalFailures,
+ sdlcPortStatsInvalidAddresses,
+ sdlcPortStatsDwarfFrames
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortStatsGroup defines objects
+ which are common to the PortStats group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 3 }
+
+
+sdlcCoreLSAdminGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcLSAddress,
+ sdlcLSAdminName,
+ sdlcLSAdminState,
+ sdlcLSAdminISTATUS,
+ sdlcLSAdminMAXDATASend,
+ sdlcLSAdminMAXDATARcv,
+ sdlcLSAdminMAXIN,
+ sdlcLSAdminMAXOUT,
+ sdlcLSAdminMODULO,
+ sdlcLSAdminRETRIESm,
+ sdlcLSAdminRETRIESt,
+ sdlcLSAdminRETRIESn,
+ sdlcLSAdminRNRLIMIT,
+ sdlcLSAdminDATMODE,
+ sdlcLSAdminGPoll,
+ sdlcLSAdminSimRim,
+ sdlcLSAdminRowStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortAdminGroup defines objects
+ which are common to the PortAdmin group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 4 }
+
+sdlcCoreLSOperGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcLSOperRole,
+ sdlcLSOperState,
+ sdlcLSOperMAXDATASend,
+ sdlcLSOperMAXIN,
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 62]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ sdlcLSOperMAXOUT,
+ sdlcLSOperMODULO,
+ sdlcLSOperRETRIESm,
+ sdlcLSOperRETRIESt,
+ sdlcLSOperRETRIESn,
+ sdlcLSOperRNRLIMIT,
+ sdlcLSOperDATMODE,
+ sdlcLSOperLastFailTime,
+ sdlcLSOperLastFailCause,
+ sdlcLSOperLastFailCtrlIn,
+ sdlcLSOperLastFailCtrlOut,
+ sdlcLSOperLastFailFRMRInfo,
+ sdlcLSOperLastFailREPLYTOs,
+ sdlcLSOperEcho,
+ sdlcLSOperGPoll
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortOperGroup defines objects
+ which are common to the PortOper group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 5 }
+
+
+sdlcCoreLSStatsGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcLSStatsBLUsIn,
+ sdlcLSStatsBLUsOut,
+ sdlcLSStatsOctetsIn,
+ sdlcLSStatsOctetsOut,
+ sdlcLSStatsPollsIn,
+ sdlcLSStatsPollsOut,
+ sdlcLSStatsPollRspsIn,
+ sdlcLSStatsPollRspsOut,
+ sdlcLSStatsLocalBusies,
+ sdlcLSStatsRemoteBusies,
+ sdlcLSStatsIFramesIn,
+ sdlcLSStatsIFramesOut,
+ sdlcLSStatsRetransmitsIn,
+ sdlcLSStatsRetransmitsOut,
+ sdlcLSStatsUIFramesIn,
+ sdlcLSStatsUIFramesOut,
+ sdlcLSStatsXIDsIn,
+ sdlcLSStatsXIDsOut,
+ sdlcLSStatsTESTsIn,
+ sdlcLSStatsTESTsOut,
+ sdlcLSStatsREJsIn,
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 63]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ sdlcLSStatsREJsOut,
+ sdlcLSStatsFRMRsIn,
+ sdlcLSStatsFRMRsOut,
+ sdlcLSStatsSIMsIn,
+ sdlcLSStatsSIMsOut,
+ sdlcLSStatsRIMsIn,
+ sdlcLSStatsRIMsOut,
+ sdlcLSStatsProtocolErrs,
+ sdlcLSStatsRNRLIMITs,
+ sdlcLSStatsRetriesExps
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcCorePortStatsGroup defines objects
+ which are common to the PortStats group of all
+ compliant link stations."
+ ::= { sdlcCoreGroups 6 }
+
+
+--
+-- Conformance Groups for Primary Link Stations
+--
+
+sdlcPrimaryGroups OBJECT IDENTIFIER ::= { sdlcGroups 2 }
+
+sdlcPrimaryGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcPortAdminPAUSE,
+ sdlcPortOperPAUSE,
+ sdlcLSAdminREPLYTO,
+ sdlcLSOperREPLYTO
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcPrimaryGroup defines objects which
+ are common to all compliant primary link
+ stations."
+ ::= { sdlcPrimaryGroups 1 }
+
+sdlcPrimaryMultipointGroup OBJECT-GROUP
+ OBJECTS
+ {
+ sdlcPortAdminSERVLIM,
+ sdlcPortAdminSlowPollTimer,
+ sdlcPortOperSlowPollMethod,
+ sdlcPortOperSERVLIM,
+ sdlcPortOperSlowPollTimer
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 64]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ }
+ STATUS current
+ DESCRIPTION
+ "The sdlcPrimaryMultipointGroup defines objects
+ which are common to all compliant primary link
+ stations that are in a multipoint topology."
+ ::= { sdlcPrimaryGroups 2 }
+
+
+END
+
+4. Acknowledgments
+
+ Thanks goes to the SNADLC MIB working group for reviewing this MIB
+ and for their infinite patience through the editing process.
+
+5. References
+
+ [1] Stewart, B., "Definitions of Managed Objects for RS-232-like
+ Hardware Devices using SMIv2", RFC 1659, Xyplex, July 1994.
+
+ [2] "Synchronous Data Link Control: Concepts", IBM Publication No.
+ GA27-3093-04, 5th edition, May 1992.
+
+ [3] "Vocabulary for Data Processing Telecommunications, and Office
+ Systems", IBM Publication No. GC20-1699-6.
+
+ [4] Kostick, D., Kielczewski, Z., and K. Shih, Editors, "Definitions
+ of Managed Objects for SNA NAUs using SMIv2", RFC 1666, Eicon
+ Technology Corporation, Bell Communications Research, Novell,
+ August 1994.
+
+ [5] Waldbusser, S., "Row Creation with SNMPv1", Work in Progress.
+
+ [6] McCloghrie K., and F. Kastenholz, "Evolution of the Interfaces
+ Group of MIB-II", RFC 1573, Hughes LAN Syst, FTP Software,
+ January 1994.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 65]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+6. Glossary
+
+ link station
+ A link station comprises procedures and control information
+ that coordinate the transfer of data between two nodes joined
+ by a link connection. All traffic over the link connection is
+ from the primary link station to one or more secondary link
+ stations, or from a secondary link station to the primary link
+ station.
+
+ primary link station
+ The link station instance on a link connection that is
+ responsible for the control of the data link. There must be
+ only one primary link station on a link connection. The
+ primary link station issues commands to one or more secondary
+ link stations.
+
+ secondary link station
+ The link station instance on a link connection that receives
+ commands from the primary link station and issues responses to
+ it.
+
+ switched line
+ A telecommunications line in which the connection is
+ established by dialing. For switched lines, the SDLC startup
+ sequence typically begins with a null exchange identifier (null
+ XID).
+
+ leased line
+ A telecommunications line on which connections do not have to
+ be established by dialing. For leased lines, the SDLC startup
+ sequence may or may not begin with an exchange identifer (XID).
+ While there are interface (e.g., RS.232) differences between
+ leased and switched lines, those interface differences do not
+ map one-to-one with differences in the SDLC startup protocol
+ (i.e., the interface and the SDLC protocol are independent from
+ one another).
+
+ point-to-point link
+ A link that connects the single primary link station to single
+ secondary link station. A point-to-point link may be either
+ switched or leased.
+
+ multipoint link
+ A link that connects the single primary link station to several
+ secondary link stations. A multipoint link may be either
+ switched or leased. Note: The physical interface signals for a
+ multipoint link are different than for a point-to-point link.
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 66]
+
+RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
+
+
+ Synonymous with multidrop line.
+
+7. Security Considerations
+
+ Security issues are not discussed in this memo.
+
+8. Authors' Addresses
+
+ Jeff Hilgeman (chair)
+ Apertus Technologies, Inc.
+ 7275 Flying Cloud Dr.
+ Eden Prarie, MN 55344
+
+ Phone: 1 612 828 0668
+ EMail: jeffh@apertus.com
+
+
+ Shannon D. Nix
+ Metaplex, Inc.
+ 7412 Wingfoot Dr.
+ Raleigh, NC 27615
+
+ Phone: 1 919 878 0811
+ EMail: snix@metaplex.com
+
+
+ Alan Bartky
+ Sync Research, Inc.
+ 7 Studebaker
+ Irvine, CA 92718
+
+ Phone: 1 714 588 2070
+ EMail: alan@sync.com
+
+
+ Wayne Clark (editor)
+ cisco Systems, Inc.
+ 3100 Smoketree Ct.
+ Suite 1000
+ Raleigh, NC 27604
+
+ Phone: 1 919 878 6958
+ EMail: wclark@cisco.com
+
+
+
+
+
+
+
+
+Hilgeman, Nix, Bartky & Clark [Page 67]
+