diff --git a/doc/rfc/rfc2108.txt b/doc/rfc/rfc2108.txt
new file mode 100644
index 0000000..69fd83c
--- /dev/null
+++ b/doc/rfc/rfc2108.txt
@@ -0,0 +1,4595 @@
+
+
+
+
+
+
+Network Working Group K. de Graaf
+Request for Comments: 2108 3Com Corporation
+Obsoletes: 1516 D. Romascanu
+Category: Standards Track Madge Networks (Israel) Ltd.
+ D. McMaster
+ Coloma Communications
+ K. McCloghrie
+ Cisco Systems Inc.
+ February 1997
+
+
+ Definitions of Managed Objects
+ for IEEE 802.3 Repeater Devices
+ using SMIv2
+
+Status of this Memo
+
+ This document specifies an Internet standards track protocol for the
+ Internet community, and requests discussion and suggestions for
+ improvements. Please refer to the current edition of the "Internet
+ Official Protocol Standards" (STD 1) for the standardization state
+ and status of this protocol. Distribution of this memo is unlimited.
+
+Abstract
+
+ This memo defines a portion of the Management Information Base (MIB)
+ for use with network management protocols in the Internet community.
+ In particular, it defines objects for managing IEEE 802.3 10 and 100
+ Mb/second baseband repeaters based on IEEE Std 802.3 Section 30, "10
+ & 100 Mb/s Management," October 26, 1995.
+
+Table of Contents
+
+ 1. The SNMP Network Management Framework.................... 2
+ 1.1. Object Definitions..................................... 2
+ 2. Overview................................................. 2
+ 2.1. Relationship to RFC 1516............................... 2
+ 2.2. Repeater Management.................................... 3
+ 2.3. Structure of the MIB................................... 4
+ 2.3.1. Basic Definitions.................................... 4
+ 2.3.2. Monitor Definitions.................................. 4
+ 2.3.3. Address Tracking Definitions......................... 4
+ 2.3.4. Top N Definitions.................................... 4
+ 2.4. Relationship to Other MIBs............................. 4
+ 2.4.1. Relationship to MIB-II............................... 4
+ 2.4.1.1. Relationship to the 'system' group................. 5
+ 2.4.1.2. Relationship to the 'interfaces' group............. 5
+ 3. Definitions............................................... 6
+
+
+
+de Graaf, et. al. Standards Track [Page 1]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ 4. Topology Mapping......................................... 75
+ 5. Acknowledgements......................................... 79
+ 6. References............................................... 80
+ 7. Security Considerations.................................. 81
+ 8. Authors' Addresses....................................... 81
+
+1. The SNMP Network Management Framework
+
+ The SNMP Network Management Framework presently consists of three
+ major components. They are:
+
+ o the SMI, described in RFC 1902 [6] - the mechanisms used
+ for describing and naming objects for the purpose of
+ management.
+
+ o the MIB-II, STD 17, RFC 1213 [5] - the core set of
+ managed objects for the Internet suite of protocols.
+
+ o the protocol, STD 15, RFC 1157 [10] and/or RFC 1905
+ [9] - the protocol used for accessing managed information.
+
+ Textual conventions are defined in RFC 1903 [7], and conformance
+ statements are defined in RFC 1904 [8].
+
+ The Framework permits new objects to be defined for the purpose of
+ experimentation and evaluation.
+
+1.1. Object Definitions
+
+ Managed objects are accessed via a virtual information store, termed
+ the Management Information Base or MIB. Objects in the MIB are
+ defined using the subset of Abstract Syntax Notation one (ASN.1)
+ defined in the SMI. In particular, each object type is named by an
+ OBJECT IDENTIFIER, an administratively assigned name. The object
+ type together with an object instance serves to uniquely identify a
+ specific instantiation of the object. For human convenience, we
+ often use a textual string, termed the descriptor, to refer to the
+ object type.
+
+2. Overview
+
+2.1. Relationship to RFC 1516
+
+ This MIB is intended as a superset of that defined by RFC 1516 [11],
+ which will go to historic status. This MIB includes all of the
+ objects contained in that MIB, plus several new ones which provide
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 2]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ for significant additional capabilities. Implementors are encouraged
+ to support all applicable conformance groups in order to make the
+ best use of the new functionality provided by this MIB. The new
+ objects provide support for:
+
+ o multiple repeaters
+
+ o 100BASE-T management
+
+ o port TopN capability
+
+ o address search and topology mapping
+
+ Certain objects have been deprecated; in particular, those scalar
+ objects used for managing a single repeater are now of minimal use
+ since they are duplicated in the new multiple- repeater definitions.
+ Additional objects have been deprecated based on implementation
+ experience with RFC 1516.
+
+2.2. Repeater Management
+
+ Instances of the object types defined in this memo represent
+ attributes of an IEEE 802.3 (Ethernet-like) repeater, as defined by
+ Section 9, "Repeater Unit for 10 Mb/s Baseband Networks" in the IEEE
+ 802.3/ISO 8802-3 CSMA/CD standard [1], and Section 27, "Repeater for
+ 100 Mb/s Baseband Networks" in the IEEE Standard 802.3u-1995 [2].
+
+ These Repeater MIB objects may be used to manage non-standard
+ repeater-like devices, but defining objects to describe
+ implementation-specific properties of non-standard repeater- like
+ devices is outside the scope of this memo.
+
+
+ The definitions presented here are based on Section 30.4, "Layer
+ Management for 10 and 100 Mb/s Baseband Repeaters" and Annex 30A,
+ "GDMO Specificataions for 802.3 managed objects" of [3].
+
+ Implementors of these MIB objects should note that [3] explicitly
+ describes when, where, and how various repeater attributes are
+ measured. The IEEE document also describes the effects of repeater
+ actions that may be invoked by manipulating instances of the MIB
+ objects defined here.
+
+ The counters in this document are defined to be the same as those
+ counters in [3], with the intention that the same instrumentation can
+ be used to implement both the IEEE and IETF management standards.
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 3]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+2.3. Structure of the MIB
+
+ Objects in this MIB are arranged into packages, each of which
+ contains a set of related objects within a broad functional category.
+ Objects within a package are generally defined under the same OID
+ subtree. These packages are intended for organizational convenience
+ ONLY, and have no relation to the conformance groups defined later in
+ the document.
+
+2.3.1. Basic Definitions
+
+ The basic definitions include objects which are applicable to all
+ repeaters: status, parameter and control objects for each repeater
+ within the managed system, for the port groups within the system, and
+ for the individual ports themselves.
+
+2.3.2. Monitor Definitions
+
+ The monitor definitions include monitoring statistics for each
+ repeater within the system and for individual ports.
+
+2.3.3. Address Tracking Definitions
+
+ This collection includes objects for tracking the MAC addresses of
+ the DTEs attached to the ports within the system and for mapping the
+ topology of a network.
+
+ Note: These definitions are based on a technology which has been
+ patented by Hewlett-Packard Company. HP has granted rights to this
+ technology to implementors of this MIB. See [12] and [13] for
+ details.
+
+2.3.4. Top N Definitions
+
+ These objects may be used for tracking the ports with the most
+ activity within the system or within particular repeaters.
+
+2.4. Relationship to Other MIBs
+
+2.4.1. Relationship to MIB-II
+
+ It is assumed that a repeater implementing this MIB will also
+ implement (at least) the 'system' group defined in MIB-II [5].
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 4]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+2.4.1.1. Relationship to the 'system' group
+
+ In MIB-II, the 'system' group is defined as being mandatory for all
+ systems such that each managed entity contains one instance of each
+ object in the 'system' group. Thus, those objects apply to the
+ entity even if the entity's sole functionality is management of
+ repeaters.
+
+2.4.1.2. Relationship to the 'interfaces' group
+
+ In MIB-II, the 'interfaces' group is defined as being mandatory for
+ all systems and contains information on an entity's interfaces, where
+ each interface is thought of as being attached to a 'subnetwork'.
+ (Note that this term is not to be confused with 'subnet' which refers
+ to an addressing partitioning scheme used in the Internet suite of
+ protocols.)
+
+ This Repeater MIB uses the notion of ports on a repeater. The
+ concept of a MIB-II interface has NO specific relationship to a
+ repeater's port. Therefore, the 'interfaces' group applies only to
+ the one (or more) network interfaces on which the entity managing the
+ repeater sends and receives management protocol operations, and does
+ not apply to the repeater's ports.
+
+ This is consistent with the physical-layer nature of a repeater. A
+ repeater is a bitwise store-and-forward device. It recognizes
+ activity and bits, but does not process incoming data based on any
+ packet-related information (such as checksum or addresses). A
+ repeater has no MAC address, no MAC implementation, and does not pass
+ packets up to higher-level protocol entities for processing.
+
+ (When a network management entity is observing a repeater, it may
+ appear as though the repeater is passing packets to a higher-level
+ protocol entity. However, this is only a means of implementing
+ management, and this passing of management information is not part of
+ the repeater functionality.)
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 5]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+3. Definitions
+
+ SNMP-REPEATER-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ Counter32, Counter64, Integer32, Gauge32, TimeTicks,
+ OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, mib-2
+ FROM SNMPv2-SMI
+ TimeStamp, DisplayString, MacAddress, TEXTUAL-CONVENTION,
+ RowStatus, TestAndIncr
+ FROM SNMPv2-TC
+ OBJECT-GROUP, MODULE-COMPLIANCE
+ FROM SNMPv2-CONF
+ OwnerString
+ FROM IF-MIB;
+
+
+ snmpRptrMod MODULE-IDENTITY
+ LAST-UPDATED "9609140000Z"
+ ORGANIZATION "IETF HUB MIB Working Group"
+ CONTACT-INFO
+ "WG E-mail: hubmib@hprnd.rose.hp.com
+
+ Chair: Dan Romascanu
+ Postal: Madge Networks (Israel) Ltd.
+ Atidim Technology Park, Bldg. 3
+ Tel Aviv 61131, Israel
+ Tel: 972-3-6458414, 6458458
+ Fax: 972-3-6487146
+ E-mail: dromasca@madge.com
+
+ Editor: Kathryn de Graaf
+ Postal: 3Com Corporation
+ 118 Turnpike Rd.
+ Southborough, MA 01772 USA
+ Tel: (508)229-1627
+ Fax: (508)490-5882
+ E-mail: kdegraaf@isd.3com.com"
+ DESCRIPTION
+ "Management information for 802.3 repeaters.
+
+ The following references are used throughout
+ this MIB module:
+
+ [IEEE 802.3 Std]
+ refers to IEEE 802.3/ISO 8802-3 Information
+ processing systems - Local area networks -
+ Part 3: Carrier sense multiple access with
+
+
+
+de Graaf, et. al. Standards Track [Page 6]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ collision detection (CSMA/CD) access method
+ and physical layer specifications (1993).
+
+ [IEEE 802.3 Mgt]
+ refers to IEEE 802.3u-1995, '10 Mb/s &
+ 100 Mb/s Management, Section 30,'
+ Supplement to ANSI/IEEE 802.3.
+
+ The following terms are used throughout this
+ MIB module. For complete formal definitions,
+ the IEEE 802.3 standards should be consulted
+ wherever possible:
+
+ System - A managed entity compliant with this
+ MIB, and incorporating at least one managed
+ 802.3 repeater.
+
+ Chassis - An enclosure for one managed repeater,
+ part of a managed repeater, or several managed
+ repeaters. It typically contains an integral
+ power supply and a variable number of available
+ module slots.
+
+ Repeater-unit - The portion of the repeater set
+ that is inboard of the physical media interfaces.
+ The physical media interfaces (MAUs, AUIs) may be
+ physically separated from the repeater-unit, or
+ they may be integrated into the same physical
+ package.
+
+ Trivial repeater-unit - An isolated port that can
+ gather statistics.
+
+ Group - A recommended, but optional, entity
+ defined by the IEEE 802.3 management standard,
+ in order to support a modular numbering scheme.
+ The classical example allows an implementor to
+ represent field-replaceable units as groups of
+ ports, with the port numbering matching the
+ modular hardware implementation.
+
+ System interconnect segment - An internal
+ segment allowing interconnection of ports
+ belonging to different physical entities
+ into the same logical manageable repeater.
+ Examples of implementation might be
+ backplane busses in modular hubs, or
+ chaining cables in stacks of hubs.
+
+
+
+de Graaf, et. al. Standards Track [Page 7]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ Stack - A scalable system that may include
+ managed repeaters, in which modularity is
+ achieved by interconnecting a number of
+ different chassis.
+
+ Module - A building block in a modular
+ chassis. It typically maps into one 'slot';
+ however, the range of configurations may be
+ very large, with several modules entering
+ one slot, or one module covering several
+ slots.
+ "
+ REVISION "9309010000Z"
+ DESCRIPTION
+ "Published as RFC 1516"
+ REVISION "9210010000Z"
+ DESCRIPTION
+ "Published as RFC 1368"
+ ::= { snmpDot3RptrMgt 5 }
+
+
+
+ snmpDot3RptrMgt OBJECT IDENTIFIER ::= { mib-2 22 }
+
+
+ OptMacAddr ::= TEXTUAL-CONVENTION
+ DISPLAY-HINT "1x:"
+ STATUS current
+ DESCRIPTION
+ "Either a 6 octet address in the `canonical'
+ order defined by IEEE 802.1a, i.e., as if it
+ were transmitted least significant bit first
+ if a value is available or a zero length string."
+ REFERENCE
+ "See MacAddress in SNMPv2-TC. The only difference
+ is that a zero length string is allowed as a value
+ for OptMacAddr and not for MacAddress."
+ SYNTAX OCTET STRING (SIZE (0 | 6))
+
+
+
+ -- Basic information at the repeater, group, and port level.
+
+ rptrBasicPackage
+ OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 }
+ rptrRptrInfo
+ OBJECT IDENTIFIER ::= { rptrBasicPackage 1 }
+ rptrGroupInfo
+
+
+
+de Graaf, et. al. Standards Track [Page 8]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ OBJECT IDENTIFIER ::= { rptrBasicPackage 2 }
+ rptrPortInfo
+ OBJECT IDENTIFIER ::= { rptrBasicPackage 3 }
+ rptrAllRptrInfo
+ OBJECT IDENTIFIER ::= { rptrBasicPackage 4 }
+
+ -- Monitoring information at the repeater, group, and port level.
+ rptrMonitorPackage
+ OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 }
+ rptrMonitorRptrInfo
+ OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 }
+ rptrMonitorGroupInfo
+ OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 }
+ rptrMonitorPortInfo
+ OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 }
+ rptrMonitorAllRptrInfo
+ OBJECT IDENTIFIER ::= { rptrMonitorPackage 4 }
+
+ -- Address tracking information at the repeater, group,
+ -- and port level.
+ rptrAddrTrackPackage
+ OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 }
+ rptrAddrTrackRptrInfo
+ OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }
+ rptrAddrTrackGroupInfo
+ -- this subtree is currently unused
+ OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }
+ rptrAddrTrackPortInfo
+ OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }
+
+ -- TopN information.
+ rptrTopNPackage
+ OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 4 }
+ rptrTopNRptrInfo
+ -- this subtree is currently unused
+ OBJECT IDENTIFIER ::= { rptrTopNPackage 1 }
+ rptrTopNGroupInfo
+ -- this subtree is currently unused
+ OBJECT IDENTIFIER ::= { rptrTopNPackage 2 }
+ rptrTopNPortInfo
+ OBJECT IDENTIFIER ::= { rptrTopNPackage 3 }
+
+
+ -- Old version of basic information at the repeater level.
+ --
+ -- In a system containing a single managed repeater,
+ -- configuration, status, and control objects for the overall
+ -- repeater.
+
+
+
+de Graaf, et. al. Standards Track [Page 9]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ --
+ -- The objects contained under the rptrRptrInfo subtree are
+ -- intended for backwards compatibility with implementations of
+ -- RFC 1516 [11]. In newer implementations (both single- and
+ -- multiple-repeater implementations) the rptrInfoTable should
+ -- be implemented. It is the preferred source of this information,
+ -- as it contains the values for all repeaters managed by the
+ -- agent. In all cases, the objects in the rptrRptrInfo subtree
+ -- are duplicates of the corresponding objects in the first entry
+ -- of the rptrInfoTable.
+
+ rptrGroupCapacity OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The rptrGroupCapacity is the number of groups
+ that can be contained within the repeater. Within
+ each managed repeater, the groups are uniquely
+ numbered in the range from 1 to rptrGroupCapacity.
+
+ Some groups may not be present in the repeater, in
+ which case the actual number of groups present
+ will be less than rptrGroupCapacity. The number
+ of groups present will never be greater than
+ rptrGroupCapacity.
+
+ Note: In practice, this will generally be the
+ number of field-replaceable units (i.e., modules,
+ cards, or boards) that can fit in the physical
+ repeater enclosure, and the group numbers will
+ correspond to numbers marked on the physical
+ enclosure."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.3,
+ aRepeaterGroupCapacity."
+ ::= { rptrRptrInfo 1 }
+
+ rptrOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- undefined or unknown
+ ok(2), -- no known failures
+ rptrFailure(3), -- repeater-related failure
+ groupFailure(4), -- group-related failure
+ portFailure(5), -- port-related failure
+ generalFailure(6) -- failure, unspecified type
+
+
+
+de Graaf, et. al. Standards Track [Page 10]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ }
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The rptrOperStatus object indicates the
+ operational state of the repeater. The
+ rptrHealthText object may be consulted for more
+ specific information about the state of the
+ repeater's health.
+
+ In the case of multiple kinds of failures (e.g.,
+ repeater failure and port failure), the value of
+ this attribute shall reflect the highest priority
+ failure in the following order, listed highest
+ priority first:
+
+ rptrFailure(3)
+ groupFailure(4)
+ portFailure(5)
+ generalFailure(6)."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
+ ::= { rptrRptrInfo 2 }
+
+ rptrHealthText OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The health text object is a text string that
+ provides information relevant to the operational
+ state of the repeater. Agents may use this string
+ to provide detailed information on current
+ failures, including how they were detected, and/or
+ instructions for problem resolution. The contents
+ are agent-specific."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.6, aRepeaterHealthText."
+ ::= { rptrRptrInfo 3 }
+
+ rptrReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noReset(1),
+ reset(2)
+
+
+
+de Graaf, et. al. Standards Track [Page 11]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ Setting this object to reset(2) causes a
+ transition to the START state of Fig 9-2 in
+ section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
+ and the START state of Fig 27-2 in section 27
+ of that standard for a 100Mb/s repeater.
+
+ Setting this object to noReset(1) has no effect.
+ The agent will always return the value noReset(1)
+ when this object is read.
+
+ After receiving a request to set this variable to
+ reset(2), the agent is allowed to delay the reset
+ for a short period. For example, the implementor
+ may choose to delay the reset long enough to allow
+ the SNMP response to be transmitted. In any
+ event, the SNMP response must be transmitted.
+
+ This action does not reset the management counters
+ defined in this document nor does it affect the
+ portAdminStatus parameters. Included in this
+ action is the execution of a disruptive Self-Test
+ with the following characteristics: a) The nature
+ of the tests is not specified. b) The test resets
+ the repeater but without affecting management
+ information about the repeater. c) The test does
+ not inject packets onto any segment. d) Packets
+ received during the test may or may not be
+ transferred. e) The test does not interfere with
+ management functions.
+
+ After performing this self-test, the agent will
+ update the repeater health information (including
+ rptrOperStatus and rptrHealthText), and send a
+ rptrHealth trap."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
+ ::= { rptrRptrInfo 4 }
+
+ rptrNonDisruptTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSelfTest(1),
+ selfTest(2)
+
+
+
+de Graaf, et. al. Standards Track [Page 12]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ }
+ MAX-ACCESS read-write
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ Setting this object to selfTest(2) causes the
+ repeater to perform a agent-specific, non-
+ disruptive self-test that has the following
+ characteristics: a) The nature of the tests is
+ not specified. b) The test does not change the
+ state of the repeater or management information
+ about the repeater. c) The test does not inject
+ packets onto any segment. d) The test does not
+ prevent the relay of any packets. e) The test
+ does not interfere with management functions.
+
+ After performing this test, the agent will update
+ the repeater health information (including
+ rptrOperStatus and rptrHealthText) and send a
+ rptrHealth trap.
+
+ Note that this definition allows returning an
+ 'okay' result after doing a trivial test.
+
+ Setting this object to noSelfTest(1) has no
+ effect. The agent will always return the value
+ noSelfTest(1) when this object is read."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.2.2,
+ acExecuteNonDisruptiveSelfTest."
+ ::= { rptrRptrInfo 5 }
+
+ rptrTotalPartitionedPorts OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ This object returns the total number of ports in
+ the repeater whose current state meets all three
+ of the following criteria: rptrPortOperStatus
+ does not have the value notPresent(3),
+ rptrPortAdminStatus is enabled(1), and
+ rptrPortAutoPartitionState is autoPartitioned(2)."
+ ::= { rptrRptrInfo 6 }
+
+
+
+
+de Graaf, et. al. Standards Track [Page 13]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ -- Basic information at the group level.
+ --
+ -- Configuration and status objects for each
+ -- managed group in the system, independent
+ -- of whether there is one or more managed
+ -- repeater-units in the system.
+
+ rptrGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of descriptive and status information about
+ the groups of ports."
+ ::= { rptrGroupInfo 1 }
+
+ rptrGroupEntry OBJECT-TYPE
+ SYNTAX RptrGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing information
+ about a single group of ports."
+ INDEX { rptrGroupIndex }
+ ::= { rptrGroupTable 1 }
+
+ RptrGroupEntry ::=
+ SEQUENCE {
+ rptrGroupIndex
+ Integer32,
+ rptrGroupDescr
+ DisplayString,
+ rptrGroupObjectID
+ OBJECT IDENTIFIER,
+ rptrGroupOperStatus
+ INTEGER,
+ rptrGroupLastOperStatusChange
+ TimeTicks,
+ rptrGroupPortCapacity
+ Integer32
+ }
+
+ rptrGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the group within the
+
+
+
+de Graaf, et. al. Standards Track [Page 14]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ system for which this entry contains
+ information."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.2.1.1, aGroupID."
+ ::= { rptrGroupEntry 1 }
+
+ rptrGroupDescr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ A textual description of the group. This value
+ should include the full name and version
+ identification of the group's hardware type and
+ indicate how the group is differentiated from
+ other types of groups in the repeater. Plug-in
+ Module, Rev A' or 'Barney Rubble 10BASE-T 4-port
+ SIMM socket Version 2.1' are examples of valid
+ group descriptions.
+
+ It is mandatory that this only contain printable
+ ASCII characters."
+ ::= { rptrGroupEntry 2 }
+
+ rptrGroupObjectID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The vendor's authoritative identification of the
+ group. This value may be allocated within the SMI
+ enterprises subtree (1.3.6.1.4.1) and provides a
+ straight-forward and unambiguous means for
+ determining what kind of group is being managed.
+
+ For example, this object could take the value
+ 1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
+ Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
+ and had assigned the identifier
+ 1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
+ 6-Port FOIRL Plug-in Module.'"
+ ::= { rptrGroupEntry 3 }
+
+ rptrGroupOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+
+
+
+de Graaf, et. al. Standards Track [Page 15]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ operational(2),
+ malfunctioning(3),
+ notPresent(4),
+ underTest(5),
+ resetInProgress(6)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An object that indicates the operational status
+ of the group.
+
+ A status of notPresent(4) indicates that the group
+ is temporarily or permanently physically and/or
+ logically not a part of the repeater. It is an
+ implementation-specific matter as to whether the
+ agent effectively removes notPresent entries from
+ the table.
+
+ A status of operational(2) indicates that the
+ group is functioning, and a status of
+ malfunctioning(3) indicates that the group is
+ malfunctioning in some way."
+ ::= { rptrGroupEntry 4 }
+
+ rptrGroupLastOperStatusChange OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ An object that contains the value of sysUpTime at
+ the time when the last of the following occurred:
+ 1) the agent cold- or warm-started;
+ 2) the row for the group was created (such
+ as when the group was added to the system); or
+ 3) the value of rptrGroupOperStatus for the
+ group changed.
+
+ A value of zero indicates that the group's
+ operational status has not changed since the agent
+ last restarted."
+ ::= { rptrGroupEntry 5 }
+
+ rptrGroupPortCapacity OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+
+
+
+de Graaf, et. al. Standards Track [Page 16]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ STATUS current
+ DESCRIPTION
+ "The rptrGroupPortCapacity is the number of ports
+ that can be contained within the group. Valid
+ range is 1-2147483647. Within each group, the
+ ports are uniquely numbered in the range from 1 to
+ rptrGroupPortCapacity.
+
+ Some ports may not be present in the system, in
+ which case the actual number of ports present
+ will be less than the value of rptrGroupPortCapacity.
+ The number of ports present in the group will never
+ be greater than the value of rptrGroupPortCapacity.
+
+ Note: In practice, this will generally be the
+ number of ports on a module, card, or board, and
+ the port numbers will correspond to numbers marked
+ on the physical embodiment."
+ REFERENCE
+ "IEEE 802.3 Mgt, 30.4.2.1.2, aGroupPortCapacity."
+ ::= { rptrGroupEntry 6 }
+
+
+ -- Basic information at the port level.
+ --
+ -- Configuration and status objects for
+ -- each managed repeater port in the system,
+ -- independent of whether there is one or more
+ -- managed repeater-units in the system.
+
+ rptrPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of descriptive and status information about
+ the repeater ports in the system. The number of
+ entries is independent of the number of repeaters
+ in the managed system."
+ ::= { rptrPortInfo 1 }
+
+ rptrPortEntry OBJECT-TYPE
+ SYNTAX RptrPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing information
+ about a single port."
+
+
+
+de Graaf, et. al. Standards Track [Page 17]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ INDEX { rptrPortGroupIndex, rptrPortIndex }
+ ::= { rptrPortTable 1 }
+
+ RptrPortEntry ::=
+ SEQUENCE {
+ rptrPortGroupIndex
+ Integer32,
+ rptrPortIndex
+ Integer32,
+ rptrPortAdminStatus
+ INTEGER,
+ rptrPortAutoPartitionState
+ INTEGER,
+ rptrPortOperStatus
+ INTEGER,
+ rptrPortRptrId
+ Integer32
+ }
+
+ rptrPortGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the group containing the
+ port for which this entry contains information."
+ ::= { rptrPortEntry 1 }
+
+ rptrPortIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the port within the group
+ for which this entry contains information. This
+ identifies the port independently from the repeater
+ it may be attached to. The numbering scheme for
+ ports is implementation specific; however, this
+ value can never be greater than
+ rptrGroupPortCapacity for the associated group."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
+ ::= { rptrPortEntry 2 }
+
+ rptrPortAdminStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabled(1),
+ disabled(2)
+
+
+
+de Graaf, et. al. Standards Track [Page 18]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object to disabled(2) disables the
+ port. A disabled port neither transmits nor
+ receives. Once disabled, a port must be
+ explicitly enabled to restore operation. A port
+ which is disabled when power is lost or when a
+ reset is exerted shall remain disabled when normal
+ operation resumes.
+
+ The admin status takes precedence over auto-
+ partition and functionally operates between the
+ auto-partition mechanism and the AUI/PMA.
+
+ Setting this object to enabled(1) enables the port
+ and exerts a BEGIN on the port's auto-partition
+ state machine.
+
+ (In effect, when a port is disabled, the value of
+ rptrPortAutoPartitionState for that port is frozen
+ until the port is next enabled. When the port
+ becomes enabled, the rptrPortAutoPartitionState
+ becomes notAutoPartitioned(1), regardless of its
+ pre-disabling state.)"
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.2, aPortAdminState
+ and 30.4.3.2.1, acPortAdminControl."
+ ::= { rptrPortEntry 3 }
+
+ rptrPortAutoPartitionState OBJECT-TYPE
+ SYNTAX INTEGER {
+ notAutoPartitioned(1),
+ autoPartitioned(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The autoPartitionState flag indicates whether the
+ port is currently partitioned by the repeater's
+ auto-partition protection.
+
+ The conditions that cause port partitioning are
+ specified in partition state machine in Sections
+ 9 and 27 of [IEEE 802.3 Std]. They are not
+ differentiated here."
+ REFERENCE
+
+
+
+de Graaf, et. al. Standards Track [Page 19]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ "[IEEE 802.3 Mgt], 30.4.3.1.3, aAutoPartitionState."
+ ::= { rptrPortEntry 4 }
+
+ rptrPortOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ operational(1),
+ notOperational(2),
+ notPresent(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object indicates the port's operational
+ status. The notPresent(3) status indicates the
+ port is physically removed (note this may or may
+ not be possible depending on the type of port.)
+ The operational(1) status indicates that the port
+ is enabled (see rptrPortAdminStatus) and working,
+ even though it might be auto-partitioned (see
+ rptrPortAutoPartitionState).
+
+ If this object has the value operational(1) and
+ rptrPortAdminStatus is set to disabled(2), it is
+ expected that this object's value will soon change
+ to notOperational(2)."
+ ::= { rptrPortEntry 5 }
+
+ rptrPortRptrId OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the repeater to
+ which this port belongs. The repeater
+ identified by a particular value of this object
+ is the same as that identified by the same
+ value of rptrInfoId. A value of zero
+ indicates that this port currently is not
+ a member of any repeater."
+ ::= { rptrPortEntry 6 }
+
+
+ -- New version of basic information at the repeater level.
+ --
+ -- Configuration, status, and control objects for
+ -- each managed repeater in the system.
+
+ rptrInfoTable OBJECT-TYPE
+
+
+
+de Graaf, et. al. Standards Track [Page 20]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ SYNTAX SEQUENCE OF RptrInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of information about each
+ non-trivial repeater. The number of entries
+ depends on the physical configuration of the
+ managed system."
+ ::= { rptrAllRptrInfo 1 }
+
+ rptrInfoEntry OBJECT-TYPE
+ SYNTAX RptrInfoEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing information
+ about a single non-trivial repeater."
+ INDEX { rptrInfoId }
+ ::= { rptrInfoTable 1 }
+
+ RptrInfoEntry ::=
+ SEQUENCE {
+ rptrInfoId
+ Integer32,
+ rptrInfoRptrType
+ INTEGER,
+ rptrInfoOperStatus
+ INTEGER,
+ rptrInfoReset
+ INTEGER,
+ rptrInfoPartitionedPorts
+ Gauge32,
+ rptrInfoLastChange
+ TimeStamp
+ }
+
+ rptrInfoId OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the repeater for which
+ this entry contains information."
+ ::= { rptrInfoEntry 1 }
+
+ rptrInfoRptrType OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1), -- undefined or unknown
+
+
+
+de Graaf, et. al. Standards Track [Page 21]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ tenMb(2),
+ onehundredMbClassI(3),
+ onehundredMbClassII(4)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The rptrInfoRptrType returns a value that identifies
+ the CSMA/CD repeater type."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.2, aRepeaterType."
+ ::= { rptrInfoEntry 2 }
+
+ rptrInfoOperStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ other(1),
+ ok(2),
+ failure(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The rptrInfoOperStatus object indicates the
+ operational state of the repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
+ ::= { rptrInfoEntry 3 }
+
+ rptrInfoReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noReset(1),
+ reset(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Setting this object to reset(2) causes a
+ transition to the START state of Fig 9-2 in
+ section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
+ and to the START state of Fig 27-2 in section 27
+ of that standard for a 100Mb/s repeater.
+
+ Setting this object to noReset(1) has no effect.
+ The agent will always return the value noReset(1)
+ when this object is read.
+
+ After receiving a request to set this variable to
+ reset(2), the agent is allowed to delay the reset
+
+
+
+de Graaf, et. al. Standards Track [Page 22]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ for a short period. For example, the implementor
+ may choose to delay the reset long enough to allow
+ the SNMP response to be transmitted. In any
+ event, the SNMP response must be transmitted.
+
+ This action does not reset the management counters
+ defined in this document nor does it affect the
+ portAdminStatus parameters. Included in this
+ action is the execution of a disruptive Self-Test
+ with the following characteristics: a) The nature
+ of the tests is not specified. b) The test resets
+ the repeater but without affecting management
+ information about the repeater. c) The test does
+ not inject packets onto any segment. d) Packets
+ received during the test may or may not be
+ transferred. e) The test does not interfere with
+ management functions.
+
+ After performing this self-test, the agent will
+ update the repeater health information (including
+ rptrInfoOperStatus), and send a rptrInfoResetEvent
+ notification."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
+ ::= { rptrInfoEntry 4 }
+
+ rptrInfoPartitionedPorts OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object returns the total number of ports in
+ the repeater whose current state meets all three
+ of the following criteria: rptrPortOperStatus
+ does not have the value notPresent(3),
+ rptrPortAdminStatus is enabled(1), and
+ rptrPortAutoPartitionState is autoPartitioned(2)."
+ ::= { rptrInfoEntry 5 }
+
+ rptrInfoLastChange OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when any of the following
+ conditions occurred:
+ 1) agent cold- or warm-started;
+ 2) this instance of repeater was created
+
+
+
+de Graaf, et. al. Standards Track [Page 23]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ (such as when a device or module was
+ added to the system);
+ 3) a change in the value of rptrInfoOperStatus;
+ 4) ports were added or removed as members of
+ the repeater; or
+ 5) any of the counters associated with this
+ repeater had a discontinuity."
+ ::= { rptrInfoEntry 6 }
+
+
+
+
+ --
+ -- Old version of statistics at the repeater level.
+ --
+ -- Performance monitoring statistics for the repeater
+ --
+ -- In a system containing a single managed repeater-unit,
+ -- the statistics object for the repeater-unit.
+
+ -- The objects contained under the rptrMonitorRptrInfo subtree are
+ -- intended for backwards compatibility with implementations of
+ -- RFC 1516 [11]. In newer implementations (both single- and
+ -- multiple-repeater implementations), the rptrMonitorTable will
+ -- be implemented. It is the preferred source of this information,
+ -- as it contains the values for all repeaters managed by the
+ -- agent. In all cases, the objects in the rptrMonitorRptrInfo
+ -- subtree are duplicates of the corresponding objects in the
+ -- first entry of the rptrMonitorTable.
+
+
+ rptrMonitorTransmitCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ For a clause 9 (10Mb/s) repeater, this counter
+ is incremented every time the repeater state
+ machine enters the TRANSMIT COLLISION state
+ from any state other than ONE PORT LEFT
+ (Ref: Fig 9-2 [IEEE 802.3 Std]).
+
+ For a clause 27 repeater, this counter is
+ incremented every time the repeater core state
+ diagram enters the Jam state as a result of
+ Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
+
+
+
+de Graaf, et. al. Standards Track [Page 24]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ The approximate minimum time for rollover of this
+ counter is 16 hours in a 10Mb/s repeater and 1.6
+ hours in a 100Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions."
+ ::= { rptrMonitorRptrInfo 1 }
+
+
+ -- Statistics at the group level.
+ --
+ -- In a system containing a single managed repeater-unit,
+ -- the statistics objects for each group.
+
+ rptrMonitorGroupTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrMonitorGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ Table of performance and error statistics for the
+ groups within the repeater. The number of entries
+ is the same as that in the rptrGroupTable."
+ ::= { rptrMonitorGroupInfo 1 }
+
+ rptrMonitorGroupEntry OBJECT-TYPE
+ SYNTAX RptrMonitorGroupEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ An entry in the table, containing total
+ performance and error statistics for a single
+ group. Regular retrieval of the information in
+ this table provides a means of tracking the
+ performance and health of the networked devices
+ attached to this group's ports.
+
+ The counters in this table are redundant in the
+ sense that they are the summations of information
+ already available through other objects. However,
+ these sums provide a considerable optimization of
+ network management traffic over the otherwise
+ necessary retrieval of the individual counters
+ included in each sum.
+
+ Note: Group-level counters are
+
+
+
+de Graaf, et. al. Standards Track [Page 25]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ deprecated in this MIB. It is recommended
+ that management applications instead use
+ the repeater-level counters contained in
+ the rptrMonTable."
+ INDEX { rptrMonitorGroupIndex }
+ ::= { rptrMonitorGroupTable 1 }
+
+ RptrMonitorGroupEntry ::=
+ SEQUENCE {
+ rptrMonitorGroupIndex
+ Integer32,
+ rptrMonitorGroupTotalFrames
+ Counter32,
+ rptrMonitorGroupTotalOctets
+ Counter32,
+ rptrMonitorGroupTotalErrors
+ Counter32
+ }
+
+ rptrMonitorGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ This object identifies the group within the
+ repeater for which this entry contains
+ information."
+ ::= { rptrMonitorGroupEntry 1 }
+
+ rptrMonitorGroupTotalFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The total number of frames of valid frame length
+ that have been received on the ports in this group
+ and for which the FCSError and CollisionEvent
+ signals were not asserted. This counter is the
+ summation of the values of the
+ rptrMonitorPortReadableFrames counters for all of
+ the ports in the group.
+
+ This statistic provides one of the parameters
+ necessary for obtaining the packet error rate.
+
+
+
+de Graaf, et. al. Standards Track [Page 26]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ The approximate minimum time for rollover of this
+ counter is 80 hours in a 10Mb/s repeater."
+ ::= { rptrMonitorGroupEntry 2 }
+
+ rptrMonitorGroupTotalOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The total number of octets contained in the valid
+ frames that have been received on the ports in
+ this group. This counter is the summation of the
+ values of the rptrMonitorPortReadableOctets
+ counters for all of the ports in the group.
+
+ This statistic provides an indicator of the total
+ data transferred. The approximate minimum time
+ for rollover of this counter is 58 minutes in a
+ 10Mb/s repeater."
+ ::= { rptrMonitorGroupEntry 3 }
+
+ rptrMonitorGroupTotalErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ The total number of errors which have occurred on
+ all of the ports in this group. This counter is
+ the summation of the values of the
+ rptrMonitorPortTotalErrors counters for all of the
+ ports in the group."
+ ::= { rptrMonitorGroupEntry 4 }
+
+
+ -- Statistics at the port level.
+ --
+
+ rptrMonitorPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrMonitorPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of performance and error statistics for the
+ ports. The number of entries is the same as that
+
+
+
+de Graaf, et. al. Standards Track [Page 27]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ in the rptrPortTable.
+
+ The columnar object rptrMonitorPortLastChange
+ is used to indicate possible discontinuities
+ of counter type columnar objects in the table."
+ ::= { rptrMonitorPortInfo 1 }
+
+ rptrMonitorPortEntry OBJECT-TYPE
+ SYNTAX RptrMonitorPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing performance and
+ error statistics for a single port."
+ INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
+ ::= { rptrMonitorPortTable 1 }
+
+ RptrMonitorPortEntry ::=
+ SEQUENCE {
+ rptrMonitorPortGroupIndex
+ Integer32,
+ rptrMonitorPortIndex
+ Integer32,
+ rptrMonitorPortReadableFrames
+ Counter32,
+ rptrMonitorPortReadableOctets
+ Counter32,
+ rptrMonitorPortFCSErrors
+ Counter32,
+ rptrMonitorPortAlignmentErrors
+ Counter32,
+ rptrMonitorPortFrameTooLongs
+ Counter32,
+ rptrMonitorPortShortEvents
+ Counter32,
+ rptrMonitorPortRunts
+ Counter32,
+ rptrMonitorPortCollisions
+ Counter32,
+ rptrMonitorPortLateEvents
+ Counter32,
+ rptrMonitorPortVeryLongEvents
+ Counter32,
+ rptrMonitorPortDataRateMismatches
+ Counter32,
+ rptrMonitorPortAutoPartitions
+ Counter32,
+ rptrMonitorPortTotalErrors
+
+
+
+de Graaf, et. al. Standards Track [Page 28]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ Counter32,
+ rptrMonitorPortLastChange
+ TimeStamp
+ }
+
+ rptrMonitorPortGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the group containing the
+ port for which this entry contains information."
+ ::= { rptrMonitorPortEntry 1 }
+
+ rptrMonitorPortIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the port within the group
+ for which this entry contains information."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
+ ::= { rptrMonitorPortEntry 2 }
+
+ rptrMonitorPortReadableFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the number of frames of valid
+ frame length that have been received on this port.
+ This counter is incremented by one for each frame
+ received on this port whose OctetCount is greater
+ than or equal to minFrameSize and less than or
+ equal to maxFrameSize (Ref: IEEE 802.3 Std,
+ 4.4.2.1) and for which the FCSError and
+ CollisionEvent signals are not asserted.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ This statistic provides one of the parameters
+ necessary for obtaining the packet error rate.
+ The approximate minimum time for rollover of this
+ counter is 80 hours at 10Mb/s."
+ REFERENCE
+
+
+
+de Graaf, et. al. Standards Track [Page 29]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ "[IEEE 802.3 Mgt], 30.4.3.1.4, aReadableFrames."
+ ::= { rptrMonitorPortEntry 3 }
+
+ rptrMonitorPortReadableOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the number of octets contained in
+ valid frames that have been received on this port.
+ This counter is incremented by OctetCount for each
+ frame received on this port which has been
+ determined to be a readable frame (i.e., including
+ FCS octets but excluding framing bits and dribble
+ bits).
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ This statistic provides an indicator of the total
+ data transferred. The approximate minimum time
+ for rollover of this counter in a 10Mb/s repeater
+ is 58 minutes.
+
+ For ports receiving traffic at a maximum rate in
+ a 100Mb/s repeater, this counter can roll over
+ in less than 6 minutes. Since that amount of time
+ could be less than a management station's poll cycle
+ time, in order to avoid a loss of information a
+ management station is advised to also poll the
+ rptrMonitorPortUpper32Octets object, or to use the
+ 64-bit counter defined by
+ rptrMonitorPortHCReadableOctets instead of the
+ two 32-bit counters."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
+ ::= { rptrMonitorPortEntry 4 }
+
+ rptrMonitorPortFCSErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each frame
+ received on this port with the FCSError signal
+ asserted and the FramingError and CollisionEvent
+ signals deasserted and whose OctetCount is greater
+
+
+
+de Graaf, et. al. Standards Track [Page 30]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ than or equal to minFrameSize and less than or
+ equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
+ Std).
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 80 hours at 10Mb/s."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.6,
+ aFrameCheckSequenceErrors."
+ ::= { rptrMonitorPortEntry 5 }
+
+ rptrMonitorPortAlignmentErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each frame
+ received on this port with the FCSError and
+ FramingError signals asserted and CollisionEvent
+ signal deasserted and whose OctetCount is greater
+ than or equal to minFrameSize and less than or
+ equal to maxFrameSize (Ref: IEEE 802.3 Std,
+ 4.4.2.1). If rptrMonitorPortAlignmentErrors is
+ incremented then the rptrMonitorPortFCSErrors
+ Counter shall not be incremented for the same
+ frame.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 80 hours at 10Mb/s."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.7, aAlignmentErrors."
+ ::= { rptrMonitorPortEntry 6 }
+
+ rptrMonitorPortFrameTooLongs OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each frame
+ received on this port whose OctetCount is greater
+
+
+
+de Graaf, et. al. Standards Track [Page 31]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
+ If rptrMonitorPortFrameTooLongs is incremented
+ then neither the rptrMonitorPortAlignmentErrors
+ nor the rptrMonitorPortFCSErrors counter shall be
+ incremented for the frame.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 61 days in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.8, aFramesTooLong."
+ ::= { rptrMonitorPortEntry 7 }
+
+ rptrMonitorPortShortEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each
+ CarrierEvent on this port with ActivityDuration
+ less than ShortEventMaxTime. ShortEventMaxTime is
+ greater than 74 bit times and less than 82 bit
+ times. ShortEventMaxTime has tolerances included
+ to provide for circuit losses between a
+ conformance test point at the AUI and the
+ measurement point within the state machine.
+
+ Notes:
+
+ ShortEvents may indicate externally
+ generated noise hits which will cause the repeater
+ to transmit Runts to its other ports, or propagate
+ a collision (which may be late) back to the
+ transmitting DTE and damaged frames to the rest of
+ the network.
+
+ Implementors may wish to consider selecting the
+ ShortEventMaxTime towards the lower end of the
+ allowed tolerance range to accommodate bit losses
+ suffered through physical channel devices not
+ budgeted for within this standard.
+
+ The significance of this attribute is different
+ in 10 and 100 Mb/s collision domains. Clause 9
+ repeaters perform fragment extension of short
+
+
+
+de Graaf, et. al. Standards Track [Page 32]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ events which would be counted as runts on the
+ interconnect ports of other repeaters. Clause
+ 27 repeaters do not perform fragment extension.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 16 hours in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.9, aShortEvents."
+ ::= { rptrMonitorPortEntry 8 }
+
+ rptrMonitorPortRunts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each
+ CarrierEvent on this port that meets one of the
+ following two conditions. Only one test need be
+ made. a) The ActivityDuration is greater than
+ ShortEventMaxTime and less than ValidPacketMinTime
+ and the CollisionEvent signal is deasserted. b)
+ The OctetCount is less than 64, the
+ ActivityDuration is greater than ShortEventMaxTime
+ and the CollisionEvent signal is deasserted.
+ ValidPacketMinTime is greater than or equal to 552
+ bit times and less than 565 bit times.
+
+ An event whose length is greater than 74 bit times
+ but less than 82 bit times shall increment either
+ the shortEvents counter or the runts counter but
+ not both. A CarrierEvent greater than or equal to
+ 552 bit times but less than 565 bit times may or
+ may not be counted as a runt.
+
+ ValidPacketMinTime has tolerances included to
+ provide for circuit losses between a conformance
+ test point at the AUI and the measurement point
+ within the state machine.
+
+ Runts usually indicate collision fragments, a
+ normal network event. In certain situations
+ associated with large diameter networks a
+ percentage of collision fragments may exceed
+ ValidPacketMinTime.
+
+
+
+de Graaf, et. al. Standards Track [Page 33]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 16 hours in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.10, aRunts."
+ ::= { rptrMonitorPortEntry 9 }
+
+ rptrMonitorPortCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For a clause 9 repeater, this counter is
+ incremented by one for any CarrierEvent signal
+ on any port for which the CollisionEvent signal
+ on this port is asserted. For a clause 27
+ repeater port the counter increments on entering
+ the Collision Count Increment state of the
+ partition state diagram (fig 27-8 of
+ [IEEE 802.3 Std]).
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 16 hours in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.11, aCollisions."
+ ::= { rptrMonitorPortEntry 10 }
+
+ rptrMonitorPortLateEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For a clause 9 repeater port, this counter is
+ incremented by one for each CarrierEvent
+ on this port in which the CollIn(X)
+ variable transitions to the value SQE (Ref:
+ 9.6.6.2, IEEE 802.3 Std) while the
+ ActivityDuration is greater than the
+ LateEventThreshold. For a clause 27 repeater
+ port, this counter is incremented by one on
+ entering the Collision Count Increment state
+
+
+
+de Graaf, et. al. Standards Track [Page 34]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ of the partition state diagram (fig 27-8)
+ while the ActivityDuration is greater than
+ the LateEvent- Threshold. Such a CarrierEvent
+ is counted twice, as both a collision and as a
+ lateEvent.
+
+ The LateEventThreshold is greater than 480 bit
+ times and less than 565 bit times.
+ LateEventThreshold has tolerances included to
+ permit an implementation to build a single
+ threshold to serve as both the LateEventThreshold
+ and ValidPacketMinTime threshold.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 81 hours in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.12, aLateEvents."
+ ::= { rptrMonitorPortEntry 11 }
+
+ rptrMonitorPortVeryLongEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For a clause 9 repeater port, this counter
+ is incremented by one for each CarrierEvent
+ whose ActivityDuration is greater than the
+ MAU Jabber Lockup Protection timer TW3
+ (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).
+
+ For a clause 27 repeater port, this counter
+ is incremented by one on entry to the
+ Rx Jabber state of the receiver timer state
+ diagram (fig 27-7). Other counters may
+ be incremented as appropriate.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.13, aVeryLongEvents."
+ ::= { rptrMonitorPortEntry 12 }
+
+ rptrMonitorPortDataRateMismatches OBJECT-TYPE
+
+
+
+de Graaf, et. al. Standards Track [Page 35]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each
+ frame received by this port that meets all
+ of the conditions required by only one of the
+ following two measurement methods:
+
+ Measurement method A: 1) The CollisionEvent
+ signal is not asserted (10Mb/s operation) or
+ the Collision Count Increment state of the
+ partition state diagram (fig 27-8 of
+ [IEEE 802.3 Std]) has not been entered
+ (100Mb/s operation). 2) The ActivityDuration
+ is greater than ValidPacketMinTime. 3) The
+ frequency (data rate) is detectably mismatched
+ from the local transmit frequency.
+
+ Measurement method B: 1) The CollisionEvent
+ signal is not asserted (10Mb/s operation)
+ or the Collision Count Increment state of the
+ partition state diagram (fig 27-8 of
+ [IEEE 802.3 Std]) has not been entered
+ (100Mb/s operation). 2) The OctetCount is
+ greater than 63. 3) The frequency (data
+ rate) is detectably mismatched from the local
+ transmit frequency. The exact degree of
+ mismatch is vendor specific and is to be
+ defined by the vendor for conformance testing.
+
+ When this event occurs, other counters whose
+ increment conditions were satisfied may or may not
+ also be incremented, at the implementor's
+ discretion. Whether or not the repeater was able
+ to maintain data integrity is beyond the scope of
+ this standard.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.14, aDataRateMismatches."
+ ::= { rptrMonitorPortEntry 13 }
+
+ rptrMonitorPortAutoPartitions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+
+
+
+de Graaf, et. al. Standards Track [Page 36]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for
+ each time the repeater has automatically
+ partitioned this port.
+
+ The conditions that cause a clause 9
+ repeater port to partition are specified in
+ the partition state diagram in clause 9 of
+ [IEEE 802.3 Std]. They are not differentiated
+ here. A clause 27 repeater port partitions
+ on entry to the Partition Wait state of the
+ partition state diagram (fig 27-8 in
+ [IEEE 802.3 Std]).
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.15, aAutoPartitions."
+ ::= { rptrMonitorPortEntry 14 }
+
+ rptrMonitorPortTotalErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of errors which have occurred on
+ this port. This counter is the summation of the
+ values of other error counters (for the same
+ port), namely:
+
+ rptrMonitorPortFCSErrors,
+ rptrMonitorPortAlignmentErrors,
+ rptrMonitorPortFrameTooLongs,
+ rptrMonitorPortShortEvents,
+ rptrMonitorPortLateEvents,
+ rptrMonitorPortVeryLongEvents,
+ rptrMonitorPortDataRateMismatches, and
+ rptrMonitorPortSymbolErrors.
+
+ This counter is redundant in the sense that it is
+ the summation of information already available
+ through other objects. However, it is included
+ specifically because the regular retrieval of this
+ object as a means of tracking the health of a port
+ provides a considerable optimization of network
+ management traffic over the otherwise necessary
+
+
+
+de Graaf, et. al. Standards Track [Page 37]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ retrieval of the summed counters.
+
+ Note that rptrMonitorPortRunts is not included
+ in this total; this is because runts usually
+ indicate collision fragments, a normal network
+ event.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ ::= { rptrMonitorPortEntry 15 }
+
+ rptrMonitorPortLastChange OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the last of
+ the following occurred:
+ 1) the agent cold- or warm-started;
+ 2) the row for the port was created
+ (such as when a device or module was added
+ to the system); or
+ 3) any condition that would cause one of
+ the counters for the row to experience
+ a discontinuity."
+ ::= { rptrMonitorPortEntry 16 }
+
+ rptrMonitor100PortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrMonitor100PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of additional performance and error
+ statistics for 100Mb/s ports, above and
+ beyond those parameters that apply to both
+ 10 and 100Mbps ports. Entries exist only for
+ ports attached to 100Mbps repeaters.
+
+ The columnar object rptrMonitorPortLastChange
+ is used to indicate possible discontinuities
+ of counter type columnar objects in this table."
+ ::= { rptrMonitorPortInfo 2 }
+
+ rptrMonitor100PortEntry OBJECT-TYPE
+ SYNTAX RptrMonitor100PortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+
+
+de Graaf, et. al. Standards Track [Page 38]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ DESCRIPTION
+ "An entry in the table, containing performance
+ and error statistics for a single 100Mb/s port."
+ INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
+ ::= { rptrMonitor100PortTable 1 }
+
+ RptrMonitor100PortEntry ::=
+ SEQUENCE {
+ rptrMonitorPortIsolates
+ Counter32,
+ rptrMonitorPortSymbolErrors
+ Counter32,
+ rptrMonitorPortUpper32Octets
+ Counter32,
+ rptrMonitorPortHCReadableOctets
+ Counter64
+ }
+
+ rptrMonitorPortIsolates OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one each time that
+ the repeater port automatically isolates as a
+ consequence of false carrier events. The conditions
+ which cause a port to automatically isolate are
+ defined by the transition from the False Carrier
+ state to the Link Unstable state of the carrier
+ integrity state diagram (figure 27-9)
+ [IEEE 802.3 Standard].
+
+ Note: Isolates do not affect the value of
+ the PortOperStatus object.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.16, aIsolates."
+ ::= { rptrMonitor100PortEntry 1 }
+
+ rptrMonitorPortSymbolErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one each time when
+
+
+
+de Graaf, et. al. Standards Track [Page 39]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ valid length packet was received at the port and
+ there was at least one occurrence of an invalid
+ data symbol. This can increment only once per valid
+ carrier event. A collision presence at any port of
+ the repeater containing port N, will not cause this
+ attribute to increment.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 7.4 hours at 100Mb/s."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.17,
+ aSymbolErrorDuringPacket."
+ ::= { rptrMonitor100PortEntry 2 }
+
+ rptrMonitorPortUpper32Octets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the number of octets contained in
+ valid frames that have been received on this port,
+ modulo 2**32. That is, it contains the upper 32
+ bits of a 64-bit octets counter, of which the
+ lower 32 bits are contained in the
+ rptrMonitorPortReadableOctets object.
+
+ This two-counter mechanism is provided for those
+ network management protocols that do not support
+ 64-bit counters (e.g. SNMP V1) and are used to
+ manage a repeater type of 100Mb/s.
+
+ Conformance clauses for this MIB are defined such
+ that implementation of this object is not required
+ in a system which does not support 100Mb/s.
+ However, systems with mixed 10 and 100Mb/s ports
+ may implement this object across all ports,
+ including 10Mb/s. If this object is implemented,
+ it must be according to the definition in the first
+ paragraph of this description; that is, the value
+ of this object MUST be a valid count.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+
+
+
+de Graaf, et. al. Standards Track [Page 40]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ ::= { rptrMonitor100PortEntry 3 }
+
+ rptrMonitorPortHCReadableOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the number of octets contained in
+ valid frames that have been received on this port.
+ This counter is incremented by OctetCount for each
+ frame received on this port which has been
+ determined to be a readable frame (i.e., including
+ FCS octets but excluding framing bits and dribble
+ bits).
+
+ This statistic provides an indicator of the total
+ data transferred.
+
+ This counter is a 64-bit version of rptrMonitor-
+ PortReadableOctets. It should be used by network
+ management protocols which suppport 64-bit counters
+ (e.g. SNMPv2).
+
+ Conformance clauses for this MIB are defined such
+ that implementation of this object is not required
+ in a system which does not support 100Mb/s.
+ However, systems with mixed 10 and 100Mb/s ports
+ may implement this object across all ports,
+ including 10Mb/s. If this object is implemented,
+ it must be according to the definition in the first
+ paragraph of this description; that is, the value
+ of this object MUST be a valid count.
+
+ A discontinuity may occur in the value
+ when the value of object
+ rptrMonitorPortLastChange changes."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
+ ::= { rptrMonitor100PortEntry 4 }
+
+
+ -- New version of statistics at the repeater level.
+ --
+ -- Statistics objects for each managed repeater
+ -- in the system.
+
+ rptrMonTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrMonEntry
+
+
+
+de Graaf, et. al. Standards Track [Page 41]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of information about each
+ non-trivial repeater. The number of entries
+ in this table is the same as the number of
+ entries in the rptrInfoTable.
+
+ The columnar object rptrInfoLastChange is
+ used to indicate possible discontinuities of
+ counter type columnar objects in this table."
+ ::= { rptrMonitorAllRptrInfo 1 }
+
+ rptrMonEntry OBJECT-TYPE
+ SYNTAX RptrMonEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing information
+ about a single non-trivial repeater."
+ INDEX { rptrInfoId }
+ ::= { rptrMonTable 1 }
+
+ RptrMonEntry ::=
+ SEQUENCE {
+ rptrMonTxCollisions
+ Counter32,
+ rptrMonTotalFrames
+ Counter32,
+ rptrMonTotalErrors
+ Counter32,
+ rptrMonTotalOctets
+ Counter32
+ }
+
+ rptrMonTxCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "For a clause 9 (10Mb/s) repeater, this counter
+ is incremented every time the repeater state
+ machine enters the TRANSMIT COLLISION state
+ from any state other than ONE PORT LEFT
+ (Ref: Fig 9-2 [IEEE 802.3 Std]).
+
+ For a clause 27 repeater, this counter is
+ incremented every time the repeater core state
+
+
+
+de Graaf, et. al. Standards Track [Page 42]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ diagram enters the Jam state as a result of
+ Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).
+
+ The approximate minimum time for rollover of this
+ counter is 16 hours in a 10Mb/s repeater and 1.6
+ hours in a 100Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions"
+ ::= { rptrMonEntry 1 }
+
+ rptrMonTotalFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of frames of valid frame length
+ that have been received on the ports in this repeater
+ and for which the FCSError and CollisionEvent
+ signals were not asserted. If an implementation
+ can not obtain a count of frames as seen by
+ the repeater itself, this counter may be
+ implemented as the summation of the values of the
+ rptrMonitorPortReadableFrames counters for all of
+ the ports in the repeater.
+
+ This statistic provides one of the parameters
+ necessary for obtaining the packet error rate.
+ The approximate minimum time for rollover of this
+ counter is 80 hours in a 10Mb/s repeater."
+ ::= { rptrMonEntry 3 }
+
+ rptrMonTotalErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of errors which have occurred on
+ all of the ports in this repeater. The errors
+ included in this count are the same as those listed
+ for the rptrMonitorPortTotalErrors counter. If an
+ implementation can not obtain a count of these
+ errors as seen by the repeater itself, this counter
+ may be implemented as the summation of the values of
+ the rptrMonitorPortTotalErrors counters for all of
+ the ports in the repeater."
+ ::= { rptrMonEntry 4 }
+
+ rptrMonTotalOctets OBJECT-TYPE
+
+
+
+de Graaf, et. al. Standards Track [Page 43]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets contained in the valid
+ frames that have been received on the ports in
+ this group. If an implementation can not obtain
+ a count of octets as seen by the repeater itself,
+ this counter may be the summation of the
+ values of the rptrMonitorPortReadableOctets
+ counters for all of the ports in the group.
+
+ This statistic provides an indicator of the total
+ data transferred. The approximate minimum time
+ for rollover of this counter in a 10Mb/s repeater
+ is 58 minutes divided by the number of ports in
+ the repeater.
+
+ For 100Mb/s repeaters processing traffic at a
+ maximum rate, this counter can roll over in less
+ than 6 minutes divided by the number of ports in
+ the repeater. Since that amount of time could
+ be less than a management station's poll cycle
+ time, in order to avoid a loss of information a
+ management station is advised to also poll the
+ rptrMonUpper32TotalOctets object, or to use the
+ 64-bit counter defined by rptrMonHCTotalOctets
+ instead of the two 32-bit counters."
+ ::= { rptrMonEntry 5 }
+
+ rptrMon100Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrMon100Entry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of additional information about each
+ 100Mb/s repeater, augmenting the entries in
+ the rptrMonTable. Entries exist in this table
+ only for 100Mb/s repeaters.
+
+ The columnar object rptrInfoLastChange is
+ used to indicate possible discontinuities of
+ counter type columnar objects in this table."
+ ::= { rptrMonitorAllRptrInfo 2 }
+
+ rptrMon100Entry OBJECT-TYPE
+ SYNTAX RptrMon100Entry
+ MAX-ACCESS not-accessible
+
+
+
+de Graaf, et. al. Standards Track [Page 44]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ STATUS current
+ DESCRIPTION
+ "An entry in the table, containing information
+ about a single 100Mbps repeater."
+ INDEX { rptrInfoId }
+ ::= { rptrMon100Table 1 }
+
+ RptrMon100Entry ::=
+ SEQUENCE {
+ rptrMonUpper32TotalOctets
+ Counter32,
+ rptrMonHCTotalOctets
+ Counter64
+ }
+
+ rptrMonUpper32TotalOctets OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets contained in the valid
+ frames that have been received on the ports in
+ this repeater, modulo 2**32. That is, it contains
+ the upper 32 bits of a 64-bit counter, of which
+ the lower 32 bits are contained in the
+ rptrMonTotalOctets object. If an implementation
+ can not obtain a count of octets as seen
+ by the repeater itself, the 64-bit value
+ may be the summation of the values of the
+ rptrMonitorPortReadableOctets counters combined
+ with the corresponding rptrMonitorPortUpper32Octets
+ counters for all of the ports in the repeater.
+
+ This statistic provides an indicator of the total
+ data transferred within the repeater.
+
+ This two-counter mechanism is provided for those
+ network management protocols that do not support
+ 64-bit counters (e.g. SNMP V1) and are used to
+ manage a repeater type of 100Mb/s.
+
+ Conformance clauses for this MIB are defined such
+ that implementation of this object is not required
+ in a system which does not support 100Mb/s.
+ However, systems with mixed 10 and 100Mb/s ports
+ may implement this object across all ports,
+ including 10Mb/s. If this object is implemented,
+ it must be according to the definition in the first
+
+
+
+de Graaf, et. al. Standards Track [Page 45]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ paragraph of this description; that is, the value
+ of this object MUST be a valid count."
+ ::= { rptrMon100Entry 1 }
+
+ rptrMonHCTotalOctets OBJECT-TYPE
+ SYNTAX Counter64
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets contained in the valid
+ frames that have been received on the ports in
+ this group. If a implementation can not obtain
+ a count of octets as seen by the repeater itself,
+ this counter may be the summation of the
+ values of the rptrMonitorPortReadableOctets
+ counters for all of the ports in the group.
+
+ This statistic provides an indicator of the total
+ data transferred.
+
+ This counter is a 64-bit (high-capacity) version
+ of rptrMonUpper32TotalOctets and rptrMonTotalOctets.
+ It should be used by network management protocols
+ which support 64-bit counters (e.g. SNMPv2).
+
+ Conformance clauses for this MIB are defined such
+ that implementation of this object is not required
+ in a system which does not support 100Mb/s.
+ However, systems with mixed 10 and 100Mb/s ports
+ may implement this object across all ports,
+ including 10Mb/s. If this object is implemented,
+ it must be according to the definition in the first
+ paragraph of this description; that is, the value
+ of this object MUST be a valid count."
+ ::= { rptrMon100Entry 2 }
+
+
+ --
+ -- The Repeater Address Search Table
+ --
+ -- This table provides an active address tracking
+ -- capability which can be also used to collect the
+ -- necessary information for mapping the topology
+ -- of a network. Note that an NMS is required to have
+ -- read-write access to the table in order to access
+ -- this function. Section 4, "Topology Mapping",
+ -- contains a description of an algorithm which can
+ -- make use of this table, in combination with the
+
+
+
+de Graaf, et. al. Standards Track [Page 46]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ -- forwarding databases of managed bridges/switches
+ -- in the network, to map network topology.
+ --
+
+ rptrAddrSearchTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrAddrSearchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table contains one entry per repeater in the
+ system. It defines objects which allow a network
+ management application to instruct an agent to watch
+ for a given MAC address and report which port it
+ was seen on. Only one address search can be in
+ progress on each repeater at any one time. Before
+ starting an address search, a management application
+ should obtain 'ownership' of the entry in
+ rptrAddrSearchTable for the repeater that is to
+ perform the search. This is accomplished with the
+ rptrAddrSearchLock and rptrAddrSearchStatus as
+ follows:
+
+ try_again:
+ get(rptrAddrSearchLock, rptrAddrSearchStatus)
+ while (rptrAddrSearchStatus != notInUse)
+ {
+ /* Loop waiting for objects to be available*/
+ short delay
+ get(rptrAddrSearchLock, rptrAddrSearchStatus)
+ }
+
+ /* Try to claim map objects */
+ lock_value = rptrAddrSearchLock
+ if ( set(rptrAddrSearchLock = lock_value,
+ rptrAddrSearchStatus = inUse,
+ rptrAddrSearchOwner = 'my-IP-address)
+ == FAILURE)
+ /* Another manager got the lock */
+ goto try_again
+
+ /* I have the lock */
+ set (rptrAddrSearchAddress = <search target>)
+
+ wait for rptrAddrSearchState to change from none
+
+ if (rptrAddrSearchState == single)
+ get (rptrAddrSearchGroup, rptrAddrSearchPort)
+
+
+
+
+de Graaf, et. al. Standards Track [Page 47]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ /* release the lock, making sure not to overwrite
+ anyone else's lock */
+ set (rptrAddrSearchLock = lock_value+1,
+ rptrAddrSearchStatus = notInUse,
+ rptrAddrSearchOwner = '')
+
+ A management station first retrieves the values of
+ the appropriate instances of the rptrAddrSearchLock
+ and rptrAddrSearchStatus objects, periodically
+ repeating the retrieval if necessary, until the value
+ of rptrAddrSearchStatus is 'notInUse'. The
+ management station then tries to set the same
+ instance of the rptrAddrSearchLock object to the
+ value it just retrieved, the same instance of the
+ rptrAddrSearchStatus object to 'inUse', and the
+ corresponding instance of rptrAddrSearchOwner to a
+ value indicating itself. If the set operation
+ succeeds, then the management station has obtained
+ ownership of the rptrAddrSearchEntry, and the value
+ of rptrAddrSearchLock is incremented by the agent (as
+ per the semantics of TestAndIncr). Failure of the
+ set operation indicates that some other manager has
+ obtained ownership of the rptrAddrSearchEntry.
+
+ Once ownership is obtained, the management station
+ can proceed with the search operation. Note that the
+ agent will reset rptrAddrSearchStatus to 'notInUse'
+ if it has been in the 'inUse' state for an abnormally
+ long period of time, to prevent a misbehaving manager
+ from permanently locking the entry. It is suggested
+ that this timeout period be between one and five
+ minutes.
+
+ When the management station has completed its search
+ operation, it should free the entry by setting
+ the instance of the rptrAddrSearchLock object to the
+ previous value + 1, the instance of the
+ rptrAddrSearchStatus to 'notInUse', and the instance
+ of rptrAddrSearchOwner to a zero length string. This
+ is done to prevent overwriting another station's
+ lock."
+ ::= { rptrAddrTrackRptrInfo 1 }
+
+ rptrAddrSearchEntry OBJECT-TYPE
+ SYNTAX RptrAddrSearchEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+
+
+
+de Graaf, et. al. Standards Track [Page 48]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ "An entry containing objects for invoking an address
+ search on a repeater."
+ INDEX { rptrInfoId }
+ ::= { rptrAddrSearchTable 1 }
+
+ RptrAddrSearchEntry ::=
+ SEQUENCE {
+ rptrAddrSearchLock TestAndIncr,
+ rptrAddrSearchStatus INTEGER,
+ rptrAddrSearchAddress MacAddress,
+ rptrAddrSearchState INTEGER,
+ rptrAddrSearchGroup Integer32,
+ rptrAddrSearchPort Integer32,
+ rptrAddrSearchOwner OwnerString
+ }
+
+
+ rptrAddrSearchLock OBJECT-TYPE
+ SYNTAX TestAndIncr
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used by a management station as an
+ advisory lock for this rptrAddrSearchEntry."
+ ::= { rptrAddrSearchEntry 1 }
+
+ rptrAddrSearchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ notInUse(1),
+ inUse(2)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "This object is used to indicate that some management
+ station is currently using this rptrAddrSearchEntry.
+ Cooperating managers should set this object to
+ 'notInUse' when they are finished using this entry.
+ The agent will automatically set the value of this
+ object to 'notInUse' if it has been set to 'inUse'
+ for an unusually long period of time."
+ ::= { rptrAddrSearchEntry 2 }
+
+ rptrAddrSearchAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+
+
+
+de Graaf, et. al. Standards Track [Page 49]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ "This object is used to search for a specified MAC
+ address. When this object is set, an address search
+ begins. This automatically sets the corresponding
+ instance of the rptrAddrSearchState object to 'none'
+ and the corresponding instances of the
+ rptrAddrSearchGroup and rptrAddrSearchPort objects to
+ 0.
+
+ When a valid frame is received by this repeater with
+ a source MAC address which matches the current value
+ of rptrAddrSearchAddress, the agent will update the
+ corresponding instances of rptrAddrSearchState,
+ rptrAddrSearchGroup and rptrAddrSearchPort to reflect
+ the current status of the search, and the group and
+ port on which the frame was seen."
+ ::= { rptrAddrSearchEntry 3 }
+
+ rptrAddrSearchState OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ single(2),
+ multiple(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current state of the MAC address search on this
+ repeater. This object is initialized to 'none' when
+ the corresponding instance of rptrAddrSearchAddress
+ is set. If the agent detects the address on exactly
+ one port, it will set this object to 'single', and
+ set the corresponding instances of
+ rptrAddrSearchGroup and rptrAddrSearchPort to reflect
+ the group and port on which the address was heard.
+ If the agent detects the address on more than one
+ port, it will set this object to 'multiple'."
+ ::= { rptrAddrSearchEntry 4 }
+
+ rptrAddrSearchGroup OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The group from which an error-free frame whose
+ source address is equal to the corresponding instance
+ of rptrAddrSearchAddress has been received. The
+ value of this object is undefined when the
+ corresponding instance of rptrAddrSearchState is
+
+
+
+de Graaf, et. al. Standards Track [Page 50]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ equal to 'none' or 'multiple'."
+ ::= { rptrAddrSearchEntry 5 }
+
+ rptrAddrSearchPort OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The port rom which an error-free frame whose
+ source address is equal to the corresponding instance
+ of rptrAddrSearchAddress has been received. The
+ value of this object is undefined when the
+ corresponding instance of rptrAddrSearchState is
+ equal to 'none' or 'multiple'."
+ ::= { rptrAddrSearchEntry 6 }
+
+ rptrAddrSearchOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The entity which currently has 'ownership' of this
+ rptrAddrSearchEntry."
+ ::= { rptrAddrSearchEntry 7 }
+
+
+ --
+ -- The Port Address Tracking Table
+ --
+ -- This table provides a way for a network management
+ -- application to passively gather information (using
+ -- read-only privileges) about which network addresses
+ -- are connected to which ports of a repeater.
+ --
+
+ rptrAddrTrackTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrAddrTrackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of address mapping information about the
+ ports."
+ ::= { rptrAddrTrackPortInfo 1 }
+
+ rptrAddrTrackEntry OBJECT-TYPE
+ SYNTAX RptrAddrTrackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+
+
+
+de Graaf, et. al. Standards Track [Page 51]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ DESCRIPTION
+ "An entry in the table, containing address mapping
+ information about a single port."
+ INDEX { rptrAddrTrackGroupIndex, rptrAddrTrackPortIndex }
+ ::= { rptrAddrTrackTable 1 }
+
+ RptrAddrTrackEntry ::=
+ SEQUENCE {
+ rptrAddrTrackGroupIndex
+ INTEGER,
+ rptrAddrTrackPortIndex
+ INTEGER,
+ rptrAddrTrackLastSourceAddress -- DEPRECATED OBJECT
+ MacAddress,
+ rptrAddrTrackSourceAddrChanges
+ Counter32,
+ rptrAddrTrackNewLastSrcAddress
+ OptMacAddr,
+ rptrAddrTrackCapacity
+ Integer32
+ }
+
+ rptrAddrTrackGroupIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the group containing the
+ port for which this entry contains information."
+ ::= { rptrAddrTrackEntry 1 }
+
+ rptrAddrTrackPortIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the port within the group
+ for which this entry contains information."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
+ ::= { rptrAddrTrackEntry 2 }
+
+ rptrAddrTrackLastSourceAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+
+
+de Graaf, et. al. Standards Track [Page 52]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ This object is the SourceAddress of the last
+ readable frame (i.e., counted by
+ rptrMonitorPortReadableFrames) received by this
+ port.
+
+ This object has been deprecated because its value
+ is undefined when no frames have been observed on
+ this port. The replacement object is
+ rptrAddrTrackNewLastSrcAddress."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
+ ::= { rptrAddrTrackEntry 3 }
+
+ rptrAddrTrackSourceAddrChanges OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This counter is incremented by one for each time
+ that the rptrAddrTrackLastSourceAddress attribute
+ for this port has changed.
+
+ This may indicate whether a link is connected to a
+ single DTE or another multi-user segment.
+
+ A discontinuity may occur in the value when the
+ value of object rptrMonitorPortLastChange changes.
+
+ The approximate minimum time for rollover of this
+ counter is 81 hours in a 10Mb/s repeater."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.19, aSourceAddressChanges."
+ ::= { rptrAddrTrackEntry 4 }
+
+ rptrAddrTrackNewLastSrcAddress OBJECT-TYPE
+ SYNTAX OptMacAddr
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object is the SourceAddress of the last
+ readable frame (i.e., counted by
+ rptrMonitorPortReadableFrames) received by this
+ port. If no frames have been received by this
+ port since the agent began monitoring the port
+ activity, the agent shall return a string of
+ length zero."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
+
+
+
+de Graaf, et. al. Standards Track [Page 53]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ ::= { rptrAddrTrackEntry 5 }
+
+ rptrAddrTrackCapacity OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of addresses that can be
+ detected on this port. This value indicates
+ to the maximum number of entries in the
+ rptrExtAddrTrackTable relative to this port.
+
+ If this object has the value of 1, the agent
+ implements only the LastSourceAddress mechanism
+ described by RFC 1368 or RFC 1516."
+ ::= { rptrAddrTrackEntry 6 }
+
+
+ -- Table for multiple addresses per port
+
+ rptrExtAddrTrackTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrExtAddrTrackEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table to extend the address tracking table (i.e.,
+ rptrAddrTrackTable) with a list of source MAC
+ addresses that were recently received on each port.
+ The number of ports is the same as the number
+ of entries in table rptrPortTable. The number of
+ entries in this table depends on the agent/repeater
+ implementation and the number of different
+ addresses received on each port.
+
+ The first entry for each port contains
+ the same MAC address that is given by the
+ rptrAddrTrackNewLastSrcAddress for that port.
+
+ Entries in this table for a particular port are
+ retained when that port is switched from one
+ repeater to another.
+
+ The ordering of MAC addresses listed for a
+ particular port is implementation dependent."
+ ::= { rptrAddrTrackPortInfo 2 }
+
+ rptrExtAddrTrackEntry OBJECT-TYPE
+ SYNTAX RptrExtAddrTrackEntry
+
+
+
+de Graaf, et. al. Standards Track [Page 54]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A row in the table of extended address tracking
+ information for ports. Entries can not be directly
+ created or deleted via SNMP operations."
+ INDEX { rptrAddrTrackGroupIndex,
+ rptrAddrTrackPortIndex,
+ rptrExtAddrTrackMacIndex }
+ ::= { rptrExtAddrTrackTable 1 }
+
+ RptrExtAddrTrackEntry ::= SEQUENCE {
+ rptrExtAddrTrackMacIndex Integer32,
+ rptrExtAddrTrackSourceAddress MacAddress
+ }
+
+ rptrExtAddrTrackMacIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of a source MAC address seen on
+ the port.
+
+ The ordering of MAC addresses listed for a
+ particular port is implementation dependent.
+
+ There is no implied relationship between a
+ particular index and a particular MAC
+ address. The index for a particular MAC
+ address may change without notice."
+ ::= { rptrExtAddrTrackEntry 1 }
+
+ rptrExtAddrTrackSourceAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The source MAC address from a readable frame
+ (i.e., counted by rptrMonitorPortReadableFrames)
+ recently received by the port."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
+ ::= { rptrExtAddrTrackEntry 2 }
+
+
+ -- The Repeater Top "N" Port Group
+
+
+
+
+de Graaf, et. al. Standards Track [Page 55]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ -- The Repeater Top N Port group is used to prepare reports that
+ -- describe a list of ports ordered by one of the statistics in the
+ -- Repeater Monitor Port Table. The statistic chosen by the
+ -- management station is sampled over a management
+ -- station-specified time interval, making the report rate based.
+ -- The management station also specifies the number of ports that
+ -- are reported.
+ --
+ -- The rptrTopNPortControlTable is used to initiate the generation
+ -- of a report. The management station may select the parameters
+ -- of such a report, such as which repeater, which statistic, how
+ -- many ports, and the start & stop times of the sampling. When
+ -- the report is prepared, entries are created in the
+ -- rptrTopNPortTable associated with the relevent
+ -- rptrTopNControlEntry. These entries are static for
+ -- each report after it has been prepared.
+
+ -- Note that counter discontinuities may appear in some
+ -- implementations if ports' assignment to repeaters changes
+ -- during the collection of data for a Top "N" report.
+ -- A management application could read the corresponding
+ -- rptrMonitorPortLastChange timestamp in order to check
+ -- whether a discontinuity occurred.
+
+
+ rptrTopNPortControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrTopNPortControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of control records for reports on the top `N'
+ ports for the rate of a selected counter. The number
+ of entries depends on the configuration of the agent.
+ The maximum number of entries is implementation
+ dependent."
+ ::= { rptrTopNPortInfo 1 }
+
+ rptrTopNPortControlEntry OBJECT-TYPE
+ SYNTAX RptrTopNPortControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that control the creation of a
+ report of the top N ports according to several metrics."
+ INDEX { rptrTopNPortControlIndex }
+ ::= { rptrTopNPortControlTable 1 }
+
+ RptrTopNPortControlEntry ::= SEQUENCE {
+
+
+
+de Graaf, et. al. Standards Track [Page 56]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ rptrTopNPortControlIndex
+ Integer32,
+ rptrTopNPortRepeaterId
+ Integer32,
+ rptrTopNPortRateBase
+ INTEGER,
+ rptrTopNPortTimeRemaining
+ Integer32,
+ rptrTopNPortDuration
+ Integer32,
+ rptrTopNPortRequestedSize
+ Integer32,
+ rptrTopNPortGrantedSize
+ Integer32,
+ rptrTopNPortStartTime
+ TimeStamp,
+ rptrTopNPortOwner
+ OwnerString,
+ rptrTopNPortRowStatus
+ RowStatus
+ }
+
+ rptrTopNPortControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1 .. 65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ rptrTopNPortControl table. Each such entry defines
+ one top N report prepared for a repeater or system."
+ ::= { rptrTopNPortControlEntry 1 }
+
+ rptrTopNPortRepeaterId OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Identifies the repeater for which a top N report will
+ be prepared (see rptrInfoId). If the value of this
+ object is positive, only ports assigned to this repeater
+ will be used to form the list in which to order the
+ Top N table. If this value is zero, all ports will be
+ eligible for inclusion on the list.
+
+ The value of this object may not be modified if the
+ associated rptrTopNPortRowStatus object is equal to
+ active(1).
+
+
+
+
+de Graaf, et. al. Standards Track [Page 57]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ If, for a particular row in this table, the repeater
+ specified by the value of this object goes away (is
+ removed from the rptrInfoTable) while the associated
+ rptrTopNPortRowStatus object is equal to active(1),
+ the row in this table is preserved by the agent but
+ the value of rptrTopNPortRowStatus is changed to
+ notInService(2), and the agent may time out the row
+ if appropriate. If the specified repeater comes
+ back (reappears in the rptrInfoTable) before the row
+ has been timed out, the management station must set
+ the value of the rptrTopNPortRowStatus object back
+ to active(1) if desired (the agent doesn't do this
+ automatically)."
+ ::= { rptrTopNPortControlEntry 2 }
+
+ rptrTopNPortRateBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ readableFrames(1),
+ readableOctets(2),
+ fcsErrors(3),
+ alignmentErrors(4),
+ frameTooLongs(5),
+ shortEvents(6),
+ runts(7),
+ collisions(8),
+ lateEvents(9),
+ veryLongEvents(10),
+ dataRateMismatches(11),
+ autoPartitions(12),
+ totalErrors(13),
+ isolates(14),
+ symbolErrors(15)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The monitored variable, which the rptrTopNPortRate
+ variable is based upon.
+
+ The value of this object may not be modified if
+ the associated rptrTopNPortRowStatus object has
+ a value of active(1)."
+ ::= { rptrTopNPortControlEntry 3 }
+
+ rptrTopNPortTimeRemaining OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-create
+ STATUS current
+
+
+
+de Graaf, et. al. Standards Track [Page 58]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ DESCRIPTION
+ "The number of seconds left in the report
+ currently being collected. When this object
+ is modified by the management station, a new
+ collection is started, possibly aborting a
+ currently running report. The new value is
+ used as the requested duration of this report,
+ which is loaded into the associated
+ rptrTopNPortDuration object.
+
+ When this object is set to a non-zero value,
+ any associated rptrTopNPortEntries shall be
+ made inaccessible by the agent. While the value
+ of this object is non-zero, it decrements by one
+ per second until it reaches zero. During this
+ time, all associated rptrTopNPortEntries shall
+ remain inaccessible. At the time that this object
+ decrements to zero, the report is made accessible
+ in the rptrTopNPortTable. Thus, the rptrTopNPort
+ table needs to be created only at the end of the
+ collection interval.
+
+ If the value of this object is set to zero
+ while the associated report is running, the
+ running report is aborted and no associated
+ rptrTopNPortEntries are created."
+ DEFVAL { 0 }
+ ::= { rptrTopNPortControlEntry 4 }
+
+ rptrTopNPortDuration OBJECT-TYPE
+ SYNTAX Integer32 (0..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of seconds that this report has
+ collected during the last sampling interval,
+ or if this report is currently being collected,
+ the number of seconds that this report is being
+ collected during this sampling interval.
+
+ When the associated rptrTopNPortTimeRemaining
+ object is set, this object shall be set by the
+ agent to the same value and shall not be modified
+ until the next time the rptrTopNPortTimeRemaining
+ is set.
+
+ This value shall be zero if no reports have been
+ requested for this rptrTopNPortControlEntry."
+
+
+
+de Graaf, et. al. Standards Track [Page 59]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ ::= { rptrTopNPortControlEntry 5 }
+
+ rptrTopNPortRequestedSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The maximum number of repeater ports requested
+ for the Top N Table.
+
+ When this object is created or modified, the
+ agent should set rptrTopNPortGrantedSize as close
+ to this object as is possible for the particular
+ implementation and available resources."
+ DEFVAL { 10 }
+ ::= { rptrTopNPortControlEntry 6 }
+
+ rptrTopNPortGrantedSize OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of repeater ports in the
+ top N table.
+
+ When the associated rptrTopNPortRequestedSize object is
+ created or modified, the agent should set this object as
+ closely to the requested value as is possible for the
+ particular implementation and available resources. The
+ agent must not lower this value except as a result of a
+ set to the associated rptrTopNPortRequestedSize object."
+ ::= { rptrTopNPortControlEntry 7 }
+
+ rptrTopNPortStartTime OBJECT-TYPE
+ SYNTAX TimeStamp
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this top N report was
+ last started. In other words, this is the time that
+ the associated rptrTopNPortTimeRemaining object was
+ modified to start the requested report.
+
+ If the report has not yet been started, the value
+ of this object is zero."
+ ::= { rptrTopNPortControlEntry 8 }
+
+ rptrTopNPortOwner OBJECT-TYPE
+
+
+
+de Graaf, et. al. Standards Track [Page 60]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is
+ using the resources assigned to it."
+ ::= { rptrTopNPortControlEntry 9 }
+
+ rptrTopNPortRowStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row.
+
+ If the value of this object is not equal to
+ active(1), all associated entries in the
+ rptrTopNPortTable shall be deleted by the
+ agent."
+ ::= { rptrTopNPortControlEntry 10 }
+
+
+ -- Top "N" reports
+
+ rptrTopNPortTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RptrTopNPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A table of reports for the top `N' ports based on
+ setting of associated control table entries. The
+ maximum number of entries depends on the number
+ of entries in table rptrTopNPortControlTable and
+ the value of object rptrTopNPortGrantedSize for
+ each entry.
+
+ For each entry in the rptrTopNPortControlTable,
+ repeater ports with the highest value of
+ rptrTopNPortRate shall be placed in this table
+ in decreasing order of that rate until there is
+ no more room or until there are no more ports."
+ ::= { rptrTopNPortInfo 2 }
+
+ rptrTopNPortEntry OBJECT-TYPE
+ SYNTAX RptrTopNPortEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+
+
+
+de Graaf, et. al. Standards Track [Page 61]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ "A set of statistics for a repeater port that is
+ part of a top N report."
+ INDEX { rptrTopNPortControlIndex,
+ rptrTopNPortIndex }
+ ::= { rptrTopNPortTable 1 }
+
+ RptrTopNPortEntry ::= SEQUENCE {
+ rptrTopNPortIndex
+ Integer32,
+ rptrTopNPortGroupIndex
+ Integer32,
+ rptrTopNPortPortIndex
+ Integer32,
+ rptrTopNPortRate
+ Gauge32
+ }
+
+ rptrTopNPortIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in
+ the rptrTopNPort table among those in the same
+ report. This index is between 1 and N, where N
+ is the number of entries in this report. Increasing
+ values of rptrTopNPortIndex shall be assigned to
+ entries with decreasing values of rptrTopNPortRate
+ until index N is assigned to the entry with the
+ lowest value of rptrTopNPortRate or there are no
+ more rptrTopNPortEntries.
+
+ No ports are included in a report where their
+ value of rptrTopNPortRate would be zero."
+ ::= { rptrTopNPortEntry 1 }
+
+ rptrTopNPortGroupIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifes the group containing
+ the port for this entry. (See also object
+ type rptrGroupIndex.)"
+ ::= { rptrTopNPortEntry 2 }
+
+ rptrTopNPortPortIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+
+
+
+de Graaf, et. al. Standards Track [Page 62]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the repeater port.
+ (See object type rptrPortIndex.)"
+ ::= { rptrTopNPortEntry 3 }
+
+ rptrTopNPortRate OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The amount of change in the selected variable
+ during this sampling interval for the identified
+ port. The selected variable is that port's
+ instance of the object selected by
+ rptrTopNPortRateBase."
+ ::= { rptrTopNPortEntry 4 }
+
+
+
+ -- Notifications for use by Repeaters
+
+ rptrHealth NOTIFICATION-TYPE
+ OBJECTS { rptrOperStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ In a system containing a single managed repeater,
+ the rptrHealth notification conveys information
+ related to the operational status of the repeater.
+ It is sent either when the value of
+ rptrOperStatus changes, or upon completion of a
+ non-disruptive test.
+
+ The rptrHealth notification must contain the
+ rptrOperStatus object. The agent may optionally
+ include the rptrHealthText object in the varBind
+ list. See the rptrOperStatus and rptrHealthText
+ objects for descriptions of the information that
+ is sent.
+
+ The agent must throttle the generation of
+ consecutive rptrHealth traps so that there is at
+ least a five-second gap between traps of this
+ type. When traps are throttled, they are dropped,
+ not queued for sending at a future time. (Note
+
+
+
+de Graaf, et. al. Standards Track [Page 63]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ that 'generating' a trap means sending to all
+ configured recipients.)"
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
+ notification."
+ ::= { snmpDot3RptrMgt 0 1 }
+
+ rptrGroupChange NOTIFICATION-TYPE
+ OBJECTS { rptrGroupIndex }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ In a system containing a single managed repeater,
+ this notification is sent when a change occurs in the
+ group structure of the repeater. This occurs only
+ when a group is logically or physically removed
+ from or added to a repeater. The varBind list
+ contains the identifier of the group that was
+ removed or added.
+
+ The agent must throttle the generation of
+ consecutive rptrGroupChange traps for the same
+ group so that there is at least a five-second gap
+ between traps of this type. When traps are
+ throttled, they are dropped, not queued for
+ sending at a future time. (Note that 'generating'
+ a trap means sending to all configured
+ recipients.)"
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.3.3, nGroupMapChange
+ notification."
+ ::= { snmpDot3RptrMgt 0 2 }
+
+ rptrResetEvent NOTIFICATION-TYPE
+ OBJECTS { rptrOperStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS OBJECT IS DEPRECATED **********
+
+ In a system containing a single managed repeater-unit,
+ the rptrResetEvent notification conveys information
+ related to the operational status of the repeater.
+ This trap is sent on completion of a repeater
+ reset action. A repeater reset action is defined
+ as an a transition to the START state of Fig 9-2
+ in section 9 [IEEE 802.3 Std], when triggered by a
+ management command (e.g., an SNMP Set on the
+
+
+
+de Graaf, et. al. Standards Track [Page 64]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ rptrReset object).
+
+ The agent must throttle the generation of
+ consecutive rptrResetEvent traps so that there is
+ at least a five-second gap between traps of this
+ type. When traps are throttled, they are dropped,
+ not queued for sending at a future time. (Note
+ that 'generating' a trap means sending to all
+ configured recipients.)
+
+ The rptrResetEvent trap is not sent when the agent
+ restarts and sends an SNMP coldStart or warmStart
+ trap. However, it is recommended that a repeater
+ agent send the rptrOperStatus object as an
+ optional object with its coldStart and warmStart
+ trap PDUs.
+
+ The rptrOperStatus object must be included in the
+ varbind list sent with this trap. The agent may
+ optionally include the rptrHealthText object as
+ well."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
+ notification."
+ ::= { snmpDot3RptrMgt 0 3 }
+
+
+ -- Notifications for repeaters in a multiple-repeater implementation.
+ -- An implementation may send either the single-repeater OR
+ -- multiple-repeater version of these notifications (1 or 4; 2 or 5)
+ -- but not both.
+
+ rptrInfoHealth NOTIFICATION-TYPE
+ OBJECTS { rptrInfoOperStatus }
+ STATUS current
+ DESCRIPTION
+ "In a system containing multiple managed repeaters,
+ the rptrInfoHealth notification conveys information
+ related to the operational status of a repeater.
+ It is sent either when the value of rptrInfoOperStatus
+ changes, or upon completion of a non-disruptive test.
+
+ The agent must throttle the generation of
+ consecutive rptrInfoHealth notifications for
+ the same repeater so that there is at least
+ a five-second gap between notifications of this type.
+ When notifications are throttled, they are dropped,
+ not queued for sending at a future time. (Note
+
+
+
+de Graaf, et. al. Standards Track [Page 65]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ that 'generating' a notification means sending
+ to all configured recipients.)"
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
+ notification."
+ ::= { snmpDot3RptrMgt 0 4 }
+
+ rptrInfoResetEvent NOTIFICATION-TYPE
+ OBJECTS { rptrInfoOperStatus }
+ STATUS current
+ DESCRIPTION
+ "In a system containing multiple managed
+ repeaters, the rptrInfoResetEvent notification
+ conveys information related to the operational
+ status of a repeater. This notification is sent
+ on completion of a repeater reset action. A
+ repeater reset action is defined as a transition
+ to the START state of Fig 9-2 in section 9 of
+ [IEEE 802.3 Std], when triggered by a management
+ command (e.g., an SNMP Set on the rptrInfoReset
+ object).
+
+ The agent must throttle the generation of
+ consecutive rptrInfoResetEvent notifications for
+ a single repeater so that there is at least
+ a five-second gap between notifications of
+ this type. When notifications are throttled,
+ they are dropped, not queued for sending at
+ a future time. (Note that 'generating' a
+ notification means sending to all configured
+ recipients.)
+
+ The rptrInfoResetEvent is not sent when the
+ agent restarts and sends an SNMP coldStart or
+ warmStart trap. However, it is recommended that
+ a repeater agent send the rptrInfoOperStatus
+ object as an optional object with its coldStart
+ and warmStart trap PDUs."
+ REFERENCE
+ "[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
+ notification."
+ ::= { snmpDot3RptrMgt 0 5 }
+
+
+ -- Conformance information
+
+ snmpRptrModConf
+ OBJECT IDENTIFIER ::= { snmpRptrMod 1 }
+
+
+
+de Graaf, et. al. Standards Track [Page 66]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ snmpRptrModCompls
+ OBJECT IDENTIFIER ::= { snmpRptrModConf 1 }
+ snmpRptrModObjGrps
+ OBJECT IDENTIFIER ::= { snmpRptrModConf 2 }
+ snmpRptrModNotGrps
+ OBJECT IDENTIFIER ::= { snmpRptrModConf 3 }
+
+
+ -- Object groups
+
+ snmpRptrGrpBasic1516 OBJECT-GROUP
+ OBJECTS { rptrGroupCapacity,
+ rptrOperStatus,
+ rptrHealthText,
+ rptrReset,
+ rptrNonDisruptTest,
+ rptrTotalPartitionedPorts,
+
+ rptrGroupIndex,
+ rptrGroupDescr,
+ rptrGroupObjectID,
+ rptrGroupOperStatus,
+ rptrGroupLastOperStatusChange,
+ rptrGroupPortCapacity,
+
+ rptrPortGroupIndex,
+ rptrPortIndex,
+ rptrPortAdminStatus,
+ rptrPortAutoPartitionState,
+ rptrPortOperStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS GROUP IS DEPRECATED **********
+
+ Basic group from RFCs 1368 and 1516.
+
+ NOTE: this object group is DEPRECATED and replaced
+ with snmpRptrGrpBasic."
+ ::= { snmpRptrModObjGrps 1 }
+
+ snmpRptrGrpMonitor1516 OBJECT-GROUP
+ OBJECTS { rptrMonitorTransmitCollisions,
+
+ rptrMonitorGroupIndex,
+ rptrMonitorGroupTotalFrames,
+ rptrMonitorGroupTotalOctets,
+ rptrMonitorGroupTotalErrors,
+
+
+
+
+de Graaf, et. al. Standards Track [Page 67]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ rptrMonitorPortGroupIndex,
+ rptrMonitorPortIndex,
+ rptrMonitorPortReadableFrames,
+ rptrMonitorPortReadableOctets,
+ rptrMonitorPortFCSErrors,
+ rptrMonitorPortAlignmentErrors,
+ rptrMonitorPortFrameTooLongs,
+ rptrMonitorPortShortEvents,
+ rptrMonitorPortRunts,
+ rptrMonitorPortCollisions,
+ rptrMonitorPortLateEvents,
+ rptrMonitorPortVeryLongEvents,
+ rptrMonitorPortDataRateMismatches,
+ rptrMonitorPortAutoPartitions,
+ rptrMonitorPortTotalErrors }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS GROUP IS DEPRECATED **********
+
+ Monitor group from RFCs 1368 and 1516.
+
+ NOTE: this object group is DEPRECATED and replaced
+ with snmpRptrGrpMonitor."
+ ::= { snmpRptrModObjGrps 2 }
+
+ snmpRptrGrpAddrTrack1368 OBJECT-GROUP
+ OBJECTS { rptrAddrTrackGroupIndex,
+ rptrAddrTrackPortIndex,
+ rptrAddrTrackLastSourceAddress,
+ rptrAddrTrackSourceAddrChanges }
+ STATUS obsolete
+ DESCRIPTION
+ "Address tracking group from RFC 1368.
+
+ NOTE: this object group is OBSOLETE and replaced
+ with snmpRptrGrpAddrTrack1516."
+ ::= { snmpRptrModObjGrps 3 }
+
+ snmpRptrGrpAddrTrack1516 OBJECT-GROUP
+ OBJECTS { rptrAddrTrackGroupIndex,
+ rptrAddrTrackPortIndex,
+ rptrAddrTrackLastSourceAddress,
+ rptrAddrTrackSourceAddrChanges,
+ rptrAddrTrackNewLastSrcAddress }
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS GROUP IS DEPRECATED **********
+
+
+
+
+de Graaf, et. al. Standards Track [Page 68]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ Address tracking group from RFC 1516.
+
+ NOTE: this object group is DEPRECATED and
+ replaced with snmpRptrGrpAddrTrack."
+ ::= { snmpRptrModObjGrps 4 }
+
+ snmpRptrGrpBasic OBJECT-GROUP
+ OBJECTS { rptrGroupIndex,
+ rptrGroupObjectID,
+ rptrGroupOperStatus,
+ rptrGroupPortCapacity,
+
+ rptrPortGroupIndex,
+ rptrPortIndex,
+ rptrPortAdminStatus,
+ rptrPortAutoPartitionState,
+ rptrPortOperStatus,
+ rptrPortRptrId,
+
+ rptrInfoId,
+ rptrInfoRptrType,
+ rptrInfoOperStatus,
+ rptrInfoReset,
+ rptrInfoPartitionedPorts,
+ rptrInfoLastChange }
+ STATUS current
+ DESCRIPTION
+ "Basic group for a system with one or more
+ repeater-units in multi-segment (post-RFC 1516)
+ version of the MIB module."
+ ::= { snmpRptrModObjGrps 5 }
+
+ snmpRptrGrpMonitor OBJECT-GROUP
+ OBJECTS { rptrMonitorPortGroupIndex,
+ rptrMonitorPortIndex,
+ rptrMonitorPortReadableFrames,
+ rptrMonitorPortReadableOctets,
+ rptrMonitorPortFCSErrors,
+ rptrMonitorPortAlignmentErrors,
+ rptrMonitorPortFrameTooLongs,
+ rptrMonitorPortShortEvents,
+ rptrMonitorPortRunts,
+ rptrMonitorPortCollisions,
+ rptrMonitorPortLateEvents,
+ rptrMonitorPortVeryLongEvents,
+ rptrMonitorPortDataRateMismatches,
+ rptrMonitorPortAutoPartitions,
+ rptrMonitorPortTotalErrors,
+
+
+
+de Graaf, et. al. Standards Track [Page 69]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ rptrMonitorPortLastChange,
+
+ rptrMonTxCollisions,
+ rptrMonTotalFrames,
+ rptrMonTotalErrors,
+ rptrMonTotalOctets }
+ STATUS current
+ DESCRIPTION
+ "Monitor group for a system with one or more
+ repeater-units in multi-segment (post-RFC 1516)
+ version of the MIB module."
+ ::= { snmpRptrModObjGrps 6 }
+
+ snmpRptrGrpMonitor100 OBJECT-GROUP
+ OBJECTS { rptrMonitorPortIsolates,
+ rptrMonitorPortSymbolErrors,
+ rptrMonitorPortUpper32Octets,
+
+ rptrMonUpper32TotalOctets }
+ STATUS current
+ DESCRIPTION
+ "Monitor group for 100Mb/s ports and repeaters
+ in a system with one or more repeater-units in
+ multi-segment (post-RFC 1516) version of the MIB
+ module. Systems which support Counter64 should
+ also implement snmpRptrGrpMonitor100w64."
+ ::= { snmpRptrModObjGrps 7 }
+
+ snmpRptrGrpMonitor100w64 OBJECT-GROUP
+ OBJECTS { rptrMonitorPortHCReadableOctets,
+ rptrMonHCTotalOctets }
+ STATUS current
+ DESCRIPTION
+ "Monitor group for 100Mb/s ports and repeaters in a
+ system with one or more repeater-units and support
+ for Counter64."
+ ::= { snmpRptrModObjGrps 8 }
+
+ snmpRptrGrpAddrTrack OBJECT-GROUP
+ OBJECTS { rptrAddrTrackGroupIndex,
+ rptrAddrTrackPortIndex,
+ rptrAddrTrackSourceAddrChanges,
+ rptrAddrTrackNewLastSrcAddress,
+ rptrAddrTrackCapacity }
+ STATUS current
+ DESCRIPTION
+ "Passive address tracking group for post-RFC 1516
+ version of the MIB module."
+
+
+
+de Graaf, et. al. Standards Track [Page 70]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ ::= { snmpRptrModObjGrps 9 }
+
+ snmpRptrGrpExtAddrTrack OBJECT-GROUP
+ OBJECTS { rptrExtAddrTrackMacIndex,
+ rptrExtAddrTrackSourceAddress }
+ STATUS current
+ DESCRIPTION
+ "Extended passive address tracking group for
+ a system with one or more repeater-units in
+ post-RFC 1516 version of the MIB module."
+ ::= { snmpRptrModObjGrps 10 }
+
+ snmpRptrGrpRptrAddrSearch OBJECT-GROUP
+ OBJECTS { rptrAddrSearchLock,
+ rptrAddrSearchStatus,
+ rptrAddrSearchAddress,
+ rptrAddrSearchState,
+ rptrAddrSearchGroup,
+ rptrAddrSearchPort,
+ rptrAddrSearchOwner }
+ STATUS current
+ DESCRIPTION
+ "Active MAC address search group and topology
+ mapping support for repeaters."
+ ::= { snmpRptrModObjGrps 11 }
+
+ snmpRptrGrpTopNPort OBJECT-GROUP
+ OBJECTS { rptrTopNPortControlIndex,
+ rptrTopNPortRepeaterId,
+ rptrTopNPortRateBase,
+ rptrTopNPortTimeRemaining,
+ rptrTopNPortDuration,
+ rptrTopNPortRequestedSize,
+ rptrTopNPortGrantedSize,
+ rptrTopNPortStartTime,
+ rptrTopNPortOwner,
+ rptrTopNPortRowStatus,
+ rptrTopNPortIndex,
+ rptrTopNPortGroupIndex,
+ rptrTopNPortPortIndex,
+ rptrTopNPortRate }
+ STATUS current
+ DESCRIPTION
+ "Top `N' group for repeater ports."
+ ::= { snmpRptrModObjGrps 12 }
+
+
+ -- Compliances
+
+
+
+de Graaf, et. al. Standards Track [Page 71]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ snmpRptrModComplRFC1368 MODULE-COMPLIANCE
+ STATUS obsolete
+ DESCRIPTION
+ "Compliance for RFC 1368.
+
+ NOTE: this module compliance is OBSOLETE and
+ replaced by snmpRptrModComplRFC1516."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { snmpRptrGrpBasic1516 }
+
+ GROUP snmpRptrGrpMonitor1516
+ DESCRIPTION
+ "Implementation of this optional group is
+ recommended for systems which have the
+ instrumentation to do performance monitoring."
+
+ GROUP snmpRptrGrpAddrTrack1368
+ DESCRIPTION
+ "Implementation of this group is
+ recommended for systems which have
+ the necessary instrumentation."
+
+ ::= { snmpRptrModCompls 1 }
+
+ snmpRptrModComplRFC1516 MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "********* THIS COMPLIANCE IS DEPRECATED **********
+
+ Compliance for RFC 1516 and for backwards
+ compatibility with single-repeater,
+ 10Mb/s-only implementations."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { snmpRptrGrpBasic1516 }
+
+ GROUP snmpRptrGrpMonitor1516
+ DESCRIPTION
+ "Implementation of this optional group is
+ recommended for systems which have the
+ instrumentation to do performance monitoring."
+
+ GROUP snmpRptrGrpAddrTrack1516
+ DESCRIPTION
+ "Implementation of this group is
+ recommended for systems which have
+ the necessary instrumentation."
+
+
+
+de Graaf, et. al. Standards Track [Page 72]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ ::= { snmpRptrModCompls 2 }
+
+ snmpRptrModCompl MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "Compliance for the multi-segment version of the
+ MIB module for a system with one or more
+ repeater-units."
+
+ MODULE -- this module
+ MANDATORY-GROUPS { snmpRptrGrpBasic,
+ snmpRptrGrpMonitor,
+ snmpRptrGrpAddrTrack }
+
+ GROUP snmpRptrGrpMonitor100
+ DESCRIPTION
+ "Implementation of this group is
+ mandatory for managed systems which
+ contain 100Mb/s repeaters."
+
+ GROUP snmpRptrGrpMonitor100w64
+ DESCRIPTION
+ "Implementation of this group is
+ mandatory for managed systems which
+ contain 100Mb/s repeaters and which
+ can support Counter64."
+
+ GROUP snmpRptrGrpExtAddrTrack
+ DESCRIPTION
+ "Implementation of this group is
+ recommended for systems which have
+ the necessary instrumentation to track
+ MAC addresses of multiple DTEs attached
+ to a single repeater port."
+
+ GROUP snmpRptrGrpRptrAddrSearch
+ DESCRIPTION
+ "Implementation of this group is
+ recommended for systems which allow
+ read-write access and which have
+ the necessary instrumentation to
+ search all incoming data streams
+ for a particular MAC address."
+
+ GROUP snmpRptrGrpTopNPort
+ DESCRIPTION
+ "Implementation of this group is
+ recommended for systems which have
+
+
+
+de Graaf, et. al. Standards Track [Page 73]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ the necessary resources to support
+ TopN statistics reporting."
+
+ ::= { snmpRptrModCompls 3 }
+
+
+ END
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 74]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+4. Topology Mapping
+
+ The network mapping algorithm presented below takes information
+ available from network devices such as repeaters, bridges, and
+ switches, and creates a representation of the physical topology of
+ the network.
+
+ Networking devices connect to the network via one or more ports.
+ Through these ports, the device is capable of hearing network packets
+ sent by other devices. By looking the source address in the packet,
+ and identifying which port the packet was heard on, the device can
+ provide information to a Network Management System about the location
+ of an address in the network, relative to that device. For devices
+ such as bridges and switches, the association of address to port can
+ be retrieved via the forwarding data base part of the Bridge MIB.
+ For repeaters, the rptrAddrSearchTable may be used to perform the
+ association.
+
+ Given this information, it would be possible for the NMS to create a
+ topology of the network which represents the physical relationships
+ of the devices in the networks. The following is an example of how
+ this might be done:
+
+ Assume the network:
+
+ =============================
+ | | |
+ | | |
+ d1 d4 d7
+ / \ |
+ / \ |
+ d2 d3 d5
+ |
+ |
+ d6
+
+ The discovery process would first determine the existence of the
+ network devices and nodes in the network. In the above example, the
+ network devices discovered would be:
+
+ d1,d2,d3,d4,d5,d6,d7
+
+ From this list of discovered devices, select (arbitrarily or via some
+ heuristic) a device as the starting point. From that device,
+ determine where all other devices are located in the network with
+ respect to the selected device.
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 75]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ For example, if d1 is the selected device, the network in relation to
+ d1 would look like:
+
+ d1
+ / | \
+ / | \
+ d2 d3 d4,d5,d6,d7
+
+ So d1 sees d2 on one port, d3 on another port, and d4, d5, and d6 on
+ the third port. In other words, using the rptrAddrSearchTable (if d1
+ is a repeater) or the Forwarding Database (if it is a bridge or a
+ switch), d1 has located d2 on one port, d1 has located d3 on another
+ port, and finally, d1 has located d4, d5, d6, and d7 on yet another
+ port.
+
+ After the first step of the algorithm is accomplished, the next and
+ final step is a recursive one. Go to each of these temporary
+ 'segments' (e.g., the segment connecting d1 and d2, or the segment
+ connecting d1 and d3, or the segment connecting d1, d4, d5, d6, and
+ d7) and determine which of these devices really belongs in that
+ segment.
+
+ As new segments are created due to this process, the recursive
+ algorithm visits them, and performs the exact same process.
+
+ In the example, the segments connecting d1 and d2, and connecting d1
+ and d3, require no further scrutiny, since there are only two nodes
+ in those segments. However, the segment connecting d1, d4, d5, d6,
+ and d7 may prove to be one or more segments, so we will investigate
+ it.
+
+ The purpose of this step is to determine which devices are really
+ connected to this segment, and which are actually connected
+ downstream. This is done by giving each of the child devices in the
+ segment (d4, d5, d6, and d7) a chance to eliminate each of the others
+ from the segment.
+
+ A device eliminates another device by showing that it hears the
+ parent device (in this case, d1) on one port, and the other device on
+ another port (different from the port on which it heard the parent).
+ If this is true, then it must mean that that device is _between_ the
+ parent device and the device which is being eliminated.
+
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 76]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ In the example, we can see that device d4 can eliminate both d5 and
+ d6, , but nobody can eliminate d4 and d7, because everybody hears
+ them on the same port that they hear the parent device (d1). So the
+ resulting topology looks like:
+
+ d1
+ / | \
+ / | \
+ d2 d3 d4,d7
+ |
+ |
+ d5,d6
+
+ Next the algorithm visits the next segment, which is the one
+ connecting d4, d5, and d6. Using the process stated above, d5 can
+ eliminate d6, since it hears d4 on a different port from where it
+ hears d6. Finally, the topology looks like:
+
+ d1
+ / | \
+ / | \
+ d2 d3 d4,d7
+ |
+ |
+ d5
+ |
+ |
+ d6
+
+
+ This is actually the topology shown at the beginning of the
+ description.
+
+ With this information about how the network devices are connected, it
+ is a relatively simple extension to then place nodes such as
+ workstations and PCs in the network. This can be done by placing the
+ node into a segment, then allowing the network devices to show that
+ the node is really not part of that segment.
+
+ This elimination can be done because the devices know what port
+ connects them to the segment on which the node is temporarily placed.
+ If they actually hear the node on a different port than that which
+ connects the device to the segment, then the node must be downstream,
+ and so it is moved onto the downstream segment. Then that segment is
+ evaluated, and so forth. Eventually, no device can show that the
+ node is connected downstream, and so it must be attached to that
+ segment.
+
+
+
+
+de Graaf, et. al. Standards Track [Page 77]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ For example, assume the network:
+
+ =============================
+ | | |
+ | | |
+ d1 d4 d7
+ / \ |
+ / \ |
+ d2 d3 d5
+ | |
+ | |
+ e1 d6
+
+ In this network, we are trying to place e1 where it belongs. We
+ begin by placing it arbitrarily into a segment:
+
+ ==================================
+ | | | |
+ | | | |
+ e1 d1 d4 d7
+ / \ |
+ / \ |
+ d2 d3 d5
+ |
+ |
+ d6
+
+ In the above case, we would give d1, d4, and d7 a chance to show that
+ e1 is not really on that segment. d4 and d7 hear e1 on the same port
+ which connects them to that segment, so they cannot eliminate e1 from
+ the segment. However, d1 will hear e1 on a different port, so we
+ move e1 down onto the segment which is connected by that port. This
+ yields the following:
+
+ =============================
+ | | |
+ | | |
+ d1 d4 d7
+ / \ |
+ / \ |
+ d2 d3,e1 d5
+ |
+ |
+ d6
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 78]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ Now we give everyone in that segment (besides that parent device, d1)
+ a chance to eliminate e1. Only d3 can try, and it succeeds, so we
+ place e1 on segment which is connected by the port on which d3 heard
+ e1. There is no segment there (yet), so we create one, and end up
+ with the following:
+
+ =============================
+ | | |
+ | | |
+ d1 d4 d7
+ / \ |
+ / \ |
+ d2 d3 d5
+ | |
+ | |
+ e1 d6
+
+ which is the correct position.
+
+5. Acknowledgements
+
+
+ This document was produced by the IETF Hub MIB Working Group, whose
+ efforts were greatly advanced by the contributions of the following
+ people:
+
+ Chuck Black
+ John Flick
+ Jeff Johnson
+ Leon Leong
+ Mike Lui
+ Dave Perkins
+ Geoff Thompson
+ Maurice Turcotte
+ Paul Woodruff
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 79]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+6. References
+
+ [1] IEEE 802.3/ISO 8802-3 Information processing systems -
+ Local area networks - Part 3: Carrier sense multiple
+ access with collision detection (CSMA/CD) access method
+ and physical layer specifications, 1993.
+
+ [2] IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium
+ Attachment Units and Repeater for 100 Mb/s Operation,
+ Type 100BASE-T," Sections 21 through 29, Supplement to
+ IEEE Std 802.3, October 26, 1995.
+
+ [3] IEEE 802.3u-1995, "10 & 100 Mb/s Management," Section 30,
+ Supplement to IEEE Std 802.3, October 26, 1995.
+
+ [4] de Graaf, K., D. Romascanu, D. McMaster, K. McCloghrie,
+ and S. Roberts, "Definitions of Managed Objects for IEEE
+ 802.3 Medium Attachment Units (MAUs)", Work in Progress.
+
+ [5] McCloghrie, K., and M. Rose, Editors, "Management
+ Information Base for Network Management of TCP/IP-based
+ internets: MIB-II", STD 17, RFC 1213, Hughes LAN Systems,
+ Performance Systems International, March 1991.
+
+ [6] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
+ and S. Waldbusser, "Structure of Management Information
+ for version 2 of the Simple Network Management Protocol
+ (SNMPv2)", RFC 1902, January 1996.
+
+ [7] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
+ and S. Waldbusser, "Textual Conventions for version 2 of
+ the Simple Network Management Protocol (SNMPv2)", RFC
+ 1903, January 1996.
+
+ [8] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
+ and S. Waldbusser, "Conformance Statements for version 2
+ of the Simple Network Management Protocol (SNMPv2)", RFC
+ 1904, January 1996.
+
+ [9] SNMPv2 Working Group, J. Case, K. McCloghrie, M. Rose,
+ and S. Waldbusser, "Protocol Operations for version 2 of
+ the Simple Network Management Protocol (SNMPv2)", RFC
+ 1905, January 1996.
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 80]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ [10] Case, J., M. Fedor, M. Schoffstall, and J. Davin, "Simple
+ Network Management Protocol", STD 15, RFC 1157, SNMP
+ Research, Performance Systems International, MIT Laboratory
+ for Computer Science, May 1990.
+
+ [11] McMaster, D., and K. McCloghrie, "Definitions of Managed
+ Objects for IEEE 802.3 Repeater Devices", RFC 1516,
+ September 1993.
+
+ [12] McAnally, G., D. Gilbert, and J. Flick, "Conditional
+ Grant of Rights to Specific Hewlett-Packard Patents In
+ Conjunction With the Internet Engineering Task Force's
+ Internet-Standard Network Management Framework", RFC 1988,
+ August 1996.
+
+ [13] Hewlett-Packard Company, US Patents 5,293,635 and
+ 5,421,024.
+
+ [14] McCloghrie, K., and F. Kastenholz, "Evolution of the
+ Interfaces Group of MIB-II", RFC 1573, January 1994.
+
+7. Security Considerations
+
+ Security issues are not discussed in this memo.
+
+8. Authors' Addresses
+
+ Kathryn de Graaf
+ 3Com Corporation
+ 118 Turnpike Rd.
+ Southborough, MA 01772 USA
+
+ Phone: (508)229-1627
+ Fax: (508)490-5882
+ EMail: kdegraaf@isd.3com.com
+
+
+ Dan Romascanu
+ Madge Networks (Israel) Ltd.
+ Atidim Technology Park, Bldg. 3
+ Tel Aviv 61131, Israel
+
+ Phone: 972-3-6458414, 6458458
+ Fax: 972-3-6487146
+ EMail: dromasca@madge.com
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 81]
+
+RFC 2108 802.3 Repeater MIB using SMIv2 February 1997
+
+
+ Donna McMaster
+ Cisco Systems Inc.
+ 170 West Tasman Drive
+ San Jose, CA 95134
+
+ Phone: (408) 526-5260
+ EMail: mcmaster@cisco.com
+
+
+ Keith McCloghrie
+ Cisco Systems Inc.
+ 170 West Tasman Drive
+ San Jose, CA 95134
+
+ Phone: (408) 526-5260
+ EMail: kzm@cisco.com
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+de Graaf, et. al. Standards Track [Page 82]
+