diff options
Diffstat (limited to 'doc/rfc/rfc2837.txt')
-rw-r--r-- | doc/rfc/rfc2837.txt | 2691 |
1 files changed, 2691 insertions, 0 deletions
diff --git a/doc/rfc/rfc2837.txt b/doc/rfc/rfc2837.txt new file mode 100644 index 0000000..8aca9d7 --- /dev/null +++ b/doc/rfc/rfc2837.txt @@ -0,0 +1,2691 @@ + + + + + + +Network Working Group K. S. Teow +Request for Comments: 2837 Brocade Communications Systems, Inc. +Category: Standards Track May 2000 + + + Definitions of Managed Objects + for the Fabric Element in Fibre Channel Standard + +Status of this Memo + + This document specifies an Internet standards track protocol for the + Internet community, and requests discussion and suggestions for + improvements. Please refer to the current edition of the "Internet + Official Protocol Standards" (STD 1) for the standardization state + and status of this protocol. Distribution of this memo is unlimited. + +Copyright Notice + + Copyright (C) The Internet Society (2000). All Rights Reserved. + +Abstract + + This memo defines an extension to the Management Information Base + (MIB) for use with network management protocols in TCP/IP-based + internets. In particular, it defines the objects for managing the + operations of the Fabric Element portion of the Fibre Channel + Standards. + +Table of Contents + + 1. The SNMP Management Framework ..................................2 + 2. Overview .......................................................3 + 2.1 Management View of a Fabric Element ...........................4 + 2.2 Structure of the Fabric Element MIB ...........................5 + 3. Object Definitions .............................................6 + The Configuration Group ......................................8 + The Module Table ...........................................9 + The FxPort Configuration Table ............................12 + The Status Group ............................................16 + The FxPort Status Table ...................................16 + The FxPort Physical Level Table ...........................18 + The FxPort Fabric Login Table .............................20 + The Error Group .............................................24 + The Accounting Groups........................................27 + The Class 1 Accounting Table ..............................27 + The Class 2 Accounting Table ..............................31 + The Class 3 Accounting Table ..............................33 + The Capability Group ........................................35 + + + +Teow Standards Track [Page 1] + +RFC 2837 FC Fabric Element MIB May 2000 + + + Conformance information .....................................38 + 4. Security Considerations .......................................43 + 5. Intellectual Property .........................................44 + 6. Acknowledgements ..............................................44 + 7. References ....................................................45 + 7.1 IETF References ..............................................45 + 7.2 Approved ANSI/NCITS References ...............................46 + 7.3 ANSI/NCITS References Under Development ......................47 + 8. Editors' Addresses ............................................47 + 9. Full Copyright Statement ......................................48 + +1. The SNMP Management Framework + + The SNMP Management Framework presently consists of five major + components: + + o An overall architecture, described in RFC 2571 [1]. + + o Mechanisms for describing and naming objects and events for the + purpose of management. The first version of this Structure of + Management Information (SMI) is called SMIv1 and described in STD + 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. The + second version, called SMIv2, is described in STD 58, RFC 2578 + [5], STD 58, RFC 2579 [6] and STD 58, RFC 2580 [7]. + + o Message protocols for transferring management information. The + first version of the SNMP message protocol is called SNMPv1 and + described in STD 15, RFC 1157 [8]. A second version of the SNMP + message protocol, which is not an Internet standards track + protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC + 1906 [10]. The third version of the message protocol is called + SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574 + [12]. + + o Protocol operations for accessing management information. The + first set of protocol operations and associated PDU formats is + described in STD 15, RFC 1157 [8]. A second set of protocol + operations and associated PDU formats is described in RFC 1905 + [13]. + + o A set of fundamental applications described in RFC 2573 [14] and + the view-based access control mechanism described in RFC 2575 + [15]. + + A more detailed introduction to the current SNMP Management Framework + can be found in RFC 2570 [16]. + + + + + +Teow Standards Track [Page 2] + +RFC 2837 FC Fabric Element MIB May 2000 + + + Managed objects are accessed via a virtual information store, termed + the Management Information Base or MIB. Objects in the MIB are + defined using the mechanisms defined in the SMI. + + This memo specifies a MIB module that is compliant to the SMIv2. A + MIB conforming to the SMIv1 can be produced through the appropriate + translations. The resulting translated MIB must be semantically + equivalent, except where objects or events are omitted because no + translation is possible (use of Counter64). Some machine readable + information in SMIv2 will be converted into textual descriptions in + SMIv1 during the translation process. However, this loss of machine + readable information is not considered to change the semantics of the + MIB. + +2. Overview + + A Fibre Channel Fabric is an entity which interconnects Node Ports + (N_Ports) or Node Loop Ports (NL_Ports). It provides transport and + routing functions. In essence, a Fabric is a network of N_Ports + and/or NL_Ports to communicate with one another. A Fabric is + composed of one or more Fabric Element that are interconnected via + Inter-element Links (IEL). A Fabric Element is the smallest unit of + a Fabric that meets the definition of a Fabric. It must consist of + at least three external ports to connect to either N_Ports, NL_Ports + or other Fabric Elements. In general, a Fabric Element port may be + of one of the following types: + + (1) F_Port, a fabric port to connect to an N_Port ([17], [21], [22]); + + (2) FL_Port, a fabric port that also supports a FC Arbitrated Loop + consisting of one or more NL_Ports ([20], [24]). + + (3) E_Port, an expansion port to connect to another Fabric Element + ([18], [23]); + + This memo shall define objects related to a Fabric Element, its + F_Ports and FL_Ports. Objects related to other types of FC ports + shall be defined in future. + + For the rest of the document, the term, "FxPort", will be used to + refer to both F_Port and FL_Port where the distinction is not + necessary. The term, "NxPort" will be used to refer to both N_Port + and NL_Port in the similar fashion. + + + + + + + + +Teow Standards Track [Page 3] + +RFC 2837 FC Fabric Element MIB May 2000 + + +2.1. Management View of a Fabric Element + + From the management perspective, it is helpful to view a Fabric + Element to be consisting of multiple "modules". Each module is a + grouping, either physical or logical, of one or more ports that may + be managed as a sub-entity within the Fabric Element. + + This module mapping is recommended but optional. A vendor may elect + to put all ports into a single module, or to divide the ports into + modules that do not match physical divisions. + + The object fcFeModuleCapacity indicates the maximum number of modules + that a given Fabric Element may contain. This value must remain + constant from one management restart to the next. + + Each module is uniquely identified by a module number in the range of + 1 through fcFeModuleCapacity inclusive. Modules may come and go + without causing a management reset (of sysUpTime), and may be + sparsely numbered within the Fabric Element. That is, the module + numbering is not required to be contiguous. For instance, if a + module is mapped physically to a field-replaceable card and in a 13- + card cage Fabric Element, cards 3, 5, 6 and 7 may be installed. The + vendor may choose to label them as modules 3, 5, 6 and 7 + respectively. In this example, the value of fcFeModuleCapacity is + 13. Note that the object fcFeModuleLastChange acts as the + discontinuity indicator for all counter objects in this MIB. + + A Fabric Element may also provide a proxy management on behalf of + another management entity by presenting it as one of its Fabric + Element modules. + + The object fcFeModuleFxPortCapacity indicates the maximum number of + ports that a given module may contain. The value of + fcFeModuleFxPortCapacity must not change for a given module. + However, a module may be deleted from the Fabric Element and replaced + with a module containing a different number of ports. The value of + fcFeModuleLastChange will indicate that a change took place. + + Each port within the Fabric Element is uniquely identified by a + combination of module index and port index, where port index is an + integer in the range (1..fcFeModuleFxPortCapacity). As with modules + within a Fabric Element, ports within a module may be sparsely + numbered. That is the port numbering is not required to be + contiguous. Likewise, ports may come and go within a module without + causing a management reset. + + + + + + +Teow Standards Track [Page 4] + +RFC 2837 FC Fabric Element MIB May 2000 + + + In terms of attachment, an F_Port will be attached to another N_Port; + and an FL_Port will be attached to one or up to 126 NL_Ports. In + general, an FxPort may be attached to one or more NxPorts. Each + NxPort associated with an FxPort will be uniquely identified by a + combination of module index, FxPort index and NxPort index. An + NxPort index is an integer in the range (1..126). The following + diagram illustrates the management view of a Fabric Element. + + #=======================================================# + # +----------------- - - - -----------------+ # + # | Module 1 [1] . . . [i] | # + # +----------------- - - - -----------------+ # + # o o o # + # +---------------------- - - - --------+ # + # | Module M [1] . . . [n] | # + # +---------------------- - - - -----^--+ # + #=====================================|=================# + | + One or more NxPorts { [1] . . . [L] }<-+ + - - - - - - - - - + where "i", "n", "M" and "L" are some arbitrary sample integer values, + and "L" must be less than 127. + +2.2. Structure of the Fabric Element MIB + + This memo assumes that a Fabric Element has an SNMP entity associated + with its managed objects. The managed objects are divided as follow: + + - the Configuration group + - the Status group + - the Error group + - the Accounting group + - the Capability group + + In each group, scalar objects and table entries are defined. + + The Configuration group contains configuration and service parameters + for the Fabric Element, modules and the FxPorts. + + The Operation group contains the operational status and parameters of + an FxPort. The group also contains the service parameters that have + been established between the FxPort and its attached NxPort, if + applicable. + + The Error group contains counters tracking various types of errors + detected by each FxPort. The information may be used for diagnostics + and/or to derive the quality of the link between an FxPort and one or + more attached NxPorts. + + + +Teow Standards Track [Page 5] + +RFC 2837 FC Fabric Element MIB May 2000 + + + The Accounting group contains statistic data suitable for deriving + accounting and performance information. + + The Capability group contains parameters indicating the inherent + capability of the Fabric Element and each FxPort. + +3. Object Definitions + +FIBRE-CHANNEL-FE-MIB DEFINITIONS ::= BEGIN + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, + Unsigned32, Counter32, Gauge32, Integer32, mib-2 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, TruthValue, TimeStamp + FROM SNMPv2-TC + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB -- rfc2571 + MODULE-COMPLIANCE, OBJECT-GROUP + FROM SNMPv2-CONF; + + fcFeMIB MODULE-IDENTITY + LAST-UPDATED "200005180000Z" + ORGANIZATION "IETF IPFC Working Group" + CONTACT-INFO "Kha Sin Teow + Brocade Communications Systems, + 1901 Guadalupe Parkway, + San Jose, CA 95131 + U.S.A + Tel: +1 408 487 8180 + Fax: +1 408 487 8190 + Email: khasin@Brocade.COM + + WG Mailing list:ipfc@standards.gadzoox.com + To Subscribe: ipfc-request@standards.gadzoox.com + In Body: subscribe" + + DESCRIPTION "The MIB module for Fibre Channel Fabric Element." + REVISION "200005180000Z" + DESCRIPTION "Initial revision, published as RFC 2837." + ::= { mib-2 75 } + + fcFeMIBObjects OBJECT IDENTIFIER ::= { fcFeMIB 1 } + + -- Note: + -- fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 } + -- see at the end of the module + + -- Groups under fcFeMIBObjects + + + +Teow Standards Track [Page 6] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFeConfig OBJECT IDENTIFIER ::= { fcFeMIBObjects 1 } + fcFeStatus OBJECT IDENTIFIER ::= { fcFeMIBObjects 2 } + fcFeError OBJECT IDENTIFIER ::= { fcFeMIBObjects 3 } + fcFeAccounting OBJECT IDENTIFIER ::= { fcFeMIBObjects 4 } + fcFeCapabilities OBJECT IDENTIFIER ::= { fcFeMIBObjects 5 } + + -- Textual Conventions + MilliSeconds ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents time unit value in milliseconds." + SYNTAX Unsigned32 + + MicroSeconds ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents time unit value in microseconds." + SYNTAX Unsigned32 + + FcNameId ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the Worldwide Name associated with + a Fibre Channel (FC) entity." + SYNTAX OCTET STRING (SIZE (8)) + + FcAddressId ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents Fibre Channel Address ID, a 24-bit + value unique within the address space of a Fabric." + SYNTAX OCTET STRING (SIZE (3)) + + FcRxDataFieldSize ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the receive data field size of an + NxPort or FxPort." + SYNTAX Integer32 (128..2112) + + FcBbCredit ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the buffer-to-buffer credit of an + NxPort or FxPort." + SYNTAX Integer32 (0..32767) + + FcphVersion ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the version of FC-PH supported by an + NxPort or FxPort." + SYNTAX Integer32 (0..255) + + FcStackedConnMode ::= TEXTUAL-CONVENTION + + + +Teow Standards Track [Page 7] + +RFC 2837 FC Fabric Element MIB May 2000 + + + STATUS current + DESCRIPTION "Represents an enumerated value used to indicate + the Class 1 Stacked Connect Mode supported by + an NxPort or FxPort." + SYNTAX INTEGER { + none(1), + transparent(2), + lockedDown(3) + } + + FcCosCap ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the class of service capability of an + NxPort or FxPort." + SYNTAX BITS { classF(0), class1(1), class2(2), class3(3), + class4(4), class5(5), class6(6) } + + FcFeModuleCapacity ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the maximum number of modules within + a Fabric Element." + SYNTAX Unsigned32 + + FcFeFxPortCapacity ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the maximum number of FxPorts within + a module." + SYNTAX Unsigned32 + + FcFeModuleIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the module index within a conceptual table." + SYNTAX Unsigned32 + + FcFeFxPortIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the FxPort index within a conceptual table." + SYNTAX Unsigned32 + + FcFeNxPortIndex ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the NxPort index within a conceptual table." + SYNTAX Integer32 (1..126) + + FcBbCreditModel ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION "Represents the BB_Credit model of an FxPort." + SYNTAX INTEGER { regular(1), alternate (2) } + + + +Teow Standards Track [Page 8] + +RFC 2837 FC Fabric Element MIB May 2000 + + + -- The Configuration group + + -- This group consists of scalar objects and tables. + -- It contains the configuration and service parameters + -- of the Fabric Element and the FxPorts. + -- The group represents a set of parameters associated with + -- the Fabric Element or an FxPort to support its NxPorts. + + fcFeFabricName OBJECT-TYPE + SYNTAX FcNameId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Name_Identifier of the Fabric to which this Fabric + Element belongs." + ::= { fcFeConfig 1 } + + fcFeElementName OBJECT-TYPE + SYNTAX FcNameId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Name_Identifier of the Fabric Element." + ::= { fcFeConfig 2 } + + fcFeModuleCapacity OBJECT-TYPE + SYNTAX FcFeModuleCapacity + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of modules in the Fabric Element, + regardless of their current state." + ::= { fcFeConfig 3 } + + -- The Module Table. + -- This table contains one entry for each module, + -- information of the modules. + + fcFeModuleTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFeModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each module in the + Fabric Element, information of the modules." + ::= { fcFeConfig 4 } + + fcFeModuleEntry OBJECT-TYPE + + + +Teow Standards Track [Page 9] + +RFC 2837 FC Fabric Element MIB May 2000 + + + SYNTAX FcFeModuleEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the configuration parameters of a + module." + INDEX { fcFeModuleIndex } + ::= { fcFeModuleTable 1 } + + + FcFeModuleEntry ::= + SEQUENCE { + fcFeModuleIndex + FcFeModuleIndex, + fcFeModuleDescr + SnmpAdminString, + fcFeModuleObjectID + OBJECT IDENTIFIER, + fcFeModuleOperStatus + INTEGER, + fcFeModuleLastChange + TimeStamp, + fcFeModuleFxPortCapacity + FcFeFxPortCapacity, + fcFeModuleName + FcNameId + } + + fcFeModuleIndex OBJECT-TYPE + SYNTAX FcFeModuleIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies the module within the Fabric Element + for which this entry contains information. This value is + never greater than fcFeModuleCapacity." + ::= { fcFeModuleEntry 1 } + + fcFeModuleDescr OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A textual description of the module. This value should + include the full name and version identification of the + module." + ::= { fcFeModuleEntry 2 } + + + + +Teow Standards Track [Page 10] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFeModuleObjectID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The vendor's authoritative identification of the module. + This value may be allocated within the SMI enterprises + subtree (1.3.6.1.4.1) and provides a straight-forward and + unambiguous means for determining what kind of module is + being managed. + + For example, this object could take the value + 1.3.6.1.4.1.99649.3.9 if vendor 'Neufe Inc.' was assigned + the subtree 1.3.6.1.4.1.99649, and had assigned the + identifier 1.3.6.1.4.1.99649.3.9 to its 'FeFiFo-16 + PlugInCard.'" + ::= { fcFeModuleEntry 3 } + + fcFeModuleOperStatus OBJECT-TYPE + SYNTAX INTEGER { + online (1), -- functional + offline (2), -- not available + testing (3), -- under testing + faulty (4) -- defective + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the operational status of the module: + online(1) the module is functioning properly; + offline(2) the module is not available; + testing(3) the module is under testing; and + faulty(4) the module is defective in some way." + ::= { fcFeModuleEntry 4 } + + fcFeModuleLastChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the value of sysUpTime when the module + entered its current operational status. A value of zero + indicates that the operational status of the module has not + changed since the agent last restarted." + ::= { fcFeModuleEntry 5 } + + fcFeModuleFxPortCapacity OBJECT-TYPE + SYNTAX FcFeFxPortCapacity + + + +Teow Standards Track [Page 11] + +RFC 2837 FC Fabric Element MIB May 2000 + + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of FxPort that can be contained within the + module. Within each module, the ports are uniquely numbered + in the range from 1 to fcFeModuleFxPortCapacity inclusive. + However, the numbers are not required to be contiguous." + ::= { fcFeModuleEntry 6 } + + fcFeModuleName OBJECT-TYPE + SYNTAX FcNameId + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Name_Identifier of the module." + ::= { fcFeModuleEntry 7 } + + -- the FxPort Configuration Table. + -- This table contains, one entry for each FxPort, + -- configuration parameters of the ports. + + fcFxPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, configuration and service parameters of the + FxPorts." + ::= { fcFeConfig 5 } + + fcFxPortEntry OBJECT-TYPE + SYNTAX FcFxPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the configuration and service parameters + of a FxPort." + INDEX { fcFeModuleIndex, fcFxPortIndex } + ::= { fcFxPortTable 1 } + + + FcFxPortEntry ::= + SEQUENCE { + fcFxPortIndex + FcFeFxPortIndex, + fcFxPortName + FcNameId, + + + +Teow Standards Track [Page 12] + +RFC 2837 FC Fabric Element MIB May 2000 + + + -- FxPort common service parameters + fcFxPortFcphVersionHigh + FcphVersion, + fcFxPortFcphVersionLow + FcphVersion, + fcFxPortBbCredit + FcBbCredit, + fcFxPortRxBufSize + FcRxDataFieldSize, + fcFxPortRatov + MilliSeconds, + fcFxPortEdtov + MilliSeconds, + -- FxPort class service parameters + fcFxPortCosSupported + FcCosCap, + fcFxPortIntermixSupported + TruthValue, + fcFxPortStackedConnMode + FcStackedConnMode, + fcFxPortClass2SeqDeliv + TruthValue, + fcFxPortClass3SeqDeliv + TruthValue, + -- other configuration parameters + fcFxPortHoldTime + MicroSeconds + } + + fcFxPortIndex OBJECT-TYPE + SYNTAX FcFeFxPortIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object identifies the FxPort within the module. This + number ranges from 1 to the value of fcFeModulePortCapacity + for the associated module. The value remains constant for + the identified FxPort until the module is re-initialized." + ::= { fcFxPortEntry 1 } + + fcFxPortName OBJECT-TYPE + SYNTAX FcNameId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The World_wide Name of this FxPort. Each FxPort has a + unique Port World_wide Name within the Fabric." + ::= { fcFxPortEntry 2 } + + + +Teow Standards Track [Page 13] + +RFC 2837 FC Fabric Element MIB May 2000 + + + -- FxPort common service parameters + + fcFxPortFcphVersionHigh OBJECT-TYPE + SYNTAX FcphVersion + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The highest or most recent version of FC-PH that the FxPort + is configured to support." + ::= { fcFxPortEntry 3 } + + fcFxPortFcphVersionLow OBJECT-TYPE + SYNTAX FcphVersion + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lowest or earliest version of FC-PH that the FxPort is + configured to support." + ::= { fcFxPortEntry 4 } + + fcFxPortBbCredit OBJECT-TYPE + SYNTAX FcBbCredit + UNITS "buffers" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of receive buffers available for holding + Class 1 connect-request, Class 2 or 3 frames from the + attached NxPort. It is for buffer-to-buffer flow control + in the direction from the attached NxPort (if applicable) + to FxPort." + ::= { fcFxPortEntry 5 } + + fcFxPortRxBufSize OBJECT-TYPE + SYNTAX FcRxDataFieldSize + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest Data_Field Size (in octets) for an FT_1 frame + that can be received by the FxPort." + ::= { fcFxPortEntry 6 } + + fcFxPortRatov OBJECT-TYPE + SYNTAX MilliSeconds + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + + + +Teow Standards Track [Page 14] + +RFC 2837 FC Fabric Element MIB May 2000 + + + DESCRIPTION + "The Resource_Allocation_Timeout Value configured for the + FxPort. This is used as the timeout value for determining + when to reuse an NxPort resource such as a + Recovery_Qualifier. It represents E_D_TOV (see next + object) plus twice the maximum time that a frame may be + delayed within the Fabric and still be delivered." + ::= { fcFxPortEntry 7 } + + fcFxPortEdtov OBJECT-TYPE + SYNTAX MilliSeconds + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The E_D_TOV value configured for the FxPort. The + Error_Detect_Timeout Value is used as the timeout value for + detecting an error condition." + ::= { fcFxPortEntry 8 } + + + -- FxPort class service parameters + + fcFxPortCosSupported OBJECT-TYPE + SYNTAX FcCosCap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value indicating the set of Classes of Service supported + by the FxPort." + ::= { fcFxPortEntry 9 } + + fcFxPortIntermixSupported OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not the FxPort supports an + Intermixed Dedicated Connection." + ::= { fcFxPortEntry 10 } + + fcFxPortStackedConnMode OBJECT-TYPE + SYNTAX FcStackedConnMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value indicating the mode of Stacked Connect supported by + the FxPort." + + + +Teow Standards Track [Page 15] + +RFC 2837 FC Fabric Element MIB May 2000 + + + ::= { fcFxPortEntry 11 } + + fcFxPortClass2SeqDeliv OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not Class 2 Sequential + Delivery is supported by the FxPort." + ::= { fcFxPortEntry 12 } + + fcFxPortClass3SeqDeliv OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not Class 3 Sequential + Delivery is supported by the FxPort." + ::= { fcFxPortEntry 13 } + + + -- other FxPort parameters + + fcFxPortHoldTime OBJECT-TYPE + SYNTAX MicroSeconds + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum time (in microseconds) that the FxPort shall + hold a frame before discarding the frame if it is unable to + deliver the frame. The value 0 means that the FxPort does + not support this parameter." + ::= { fcFxPortEntry 14 } + + + -- the Status group + + -- This group consists of tables that contains operational + -- status and established service parameters for the Fabric + -- Element and the attached NxPorts. + + -- The FxPort Status table + -- This table contains, one entry for each FxPort, + -- the operational status and parameters of the FxPorts. + + fcFxPortStatusTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortStatusEntry + + + +Teow Standards Track [Page 16] + +RFC 2837 FC Fabric Element MIB May 2000 + + + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, operational status and parameters of the + FxPorts." + ::= { fcFeStatus 1 } + + fcFxPortStatusEntry OBJECT-TYPE + SYNTAX FcFxPortStatusEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing operational status and parameters of a + FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortStatusTable 1 } + + + FcFxPortStatusEntry ::= + SEQUENCE { + fcFxPortID + FcAddressId, + fcFxPortBbCreditAvailable + Gauge32, + fcFxPortOperMode + INTEGER, + fcFxPortAdminMode + INTEGER + } + + fcFxPortID OBJECT-TYPE + SYNTAX FcAddressId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address identifier by which this FxPort is identified + within the Fabric. The FxPort may assign its address + identifier to its attached NxPort(s) during Fabric Login." + ::= { fcFxPortStatusEntry 1 } + + fcFxPortBbCreditAvailable OBJECT-TYPE + SYNTAX Gauge32 + UNITS "buffers" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of buffers currently available for receiving + + + +Teow Standards Track [Page 17] + +RFC 2837 FC Fabric Element MIB May 2000 + + + frames from the attached port in the buffer-to-buffer flow + control. The value should be less than or equal to + fcFxPortBbCredit." + ::= { fcFxPortStatusEntry 2 } + + fcFxPortOperMode OBJECT-TYPE + SYNTAX INTEGER { unknown(1), fPort(2), flPort(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current operational mode of the FxPort." + ::= { fcFxPortStatusEntry 3 } + + fcFxPortAdminMode OBJECT-TYPE + SYNTAX INTEGER { fPort(2), flPort(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The desired operational mode of the FxPort." + ::= { fcFxPortStatusEntry 4 } + + + -- the FxPort Physical Level table + -- This table contains, one entry for each FxPort in the + -- Fabric Element, the physical level status and parameters + -- of the FxPorts. + + fcFxPortPhysTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortPhysEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, physical level status and parameters of the + FxPorts." + ::= { fcFeStatus 2 } + + fcFxPortPhysEntry OBJECT-TYPE + SYNTAX FcFxPortPhysEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing physical level status and parameters of + a FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortPhysTable 1 } + + FcFxPortPhysEntry ::= + + + +Teow Standards Track [Page 18] + +RFC 2837 FC Fabric Element MIB May 2000 + + + SEQUENCE { + fcFxPortPhysAdminStatus + INTEGER, + fcFxPortPhysOperStatus + INTEGER, + fcFxPortPhysLastChange + TimeStamp, + fcFxPortPhysRttov + MilliSeconds + } + + fcFxPortPhysAdminStatus OBJECT-TYPE + SYNTAX INTEGER { + online (1), -- place port online + offline (2), -- take port offline + testing (3) -- initiate test procedures + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The desired state of the FxPort. A management station may + place the FxPort in a desired state by setting this object + accordingly. The testing(3) state indicates that no + operational frames can be passed. When a Fabric Element + initializes, all FxPorts start with fcFxPortPhysAdminStatus + in the offline(2) state. As the result of either explicit + management action or per configuration information + accessible by the Fabric Element, fcFxPortPhysAdminStatus + is then changed to either the online(1) or testing(3) + states, or remains in the offline state." + ::= { fcFxPortPhysEntry 1 } + + fcFxPortPhysOperStatus OBJECT-TYPE + SYNTAX INTEGER { + online (1), -- Login may proceed + offline (2), -- Login cannot proceed + testing (3), -- port is under test + linkFailure (4) -- failure after online/testing + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current operational status of the FxPort. The + testing(3) indicates that no operational frames can be + passed. If fcFxPortPhysAdminStatus is offline(2) then + fcFxPortPhysOperStatus should be offline(2). If + fcFxPortPhysAdminStatus is changed to online(1) then + fcFxPortPhysOperStatus should change to online(1) if the + + + +Teow Standards Track [Page 19] + +RFC 2837 FC Fabric Element MIB May 2000 + + + FxPort is ready to accept Fabric Login request from the + attached NxPort; it should proceed and remain in the link- + failure(4) state if and only if there is a fault that + prevents it from going to the online(1) state." + ::= { fcFxPortPhysEntry 2 } + + fcFxPortPhysLastChange OBJECT-TYPE + SYNTAX TimeStamp + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time the FxPort entered its + current operational status. A value of zero indicates that + the FxPort's operational status has not changed since the + agent last restarted." + ::= { fcFxPortPhysEntry 3 } + + fcFxPortPhysRttov OBJECT-TYPE + SYNTAX MilliSeconds + UNITS "milliseconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Receiver_Transmitter_Timeout value of the FxPort. This + is used by the receiver logic to detect Loss of + Synchronization." + ::= { fcFxPortPhysEntry 4 } + + -- The FxPort Fabric Login table + -- + -- This table contains, one entry for each FxPort in the + -- Fabric Element, the Service Parameters that have been + -- established from the most recent Fabric Login, + -- implicit or explicit. + + fcFxLoginTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxLoginEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each NxPort attached + to a particular FxPort in the Fabric Element, services + parameters established from the most recent Fabric Login, + explicit or implicit. Note that an FxPort may have one or + more NxPort attached to it." + ::= { fcFeStatus 3 } + + + + + +Teow Standards Track [Page 20] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFxLoginEntry OBJECT-TYPE + SYNTAX FcFxLoginEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing service parameters established from a + successful Fabric Login." + INDEX { fcFeModuleIndex, fcFxPortIndex, fcFxPortNxLoginIndex } + ::= { fcFxLoginTable 1 } + + FcFxLoginEntry ::= + SEQUENCE { + fcFxPortNxLoginIndex + FcFeNxPortIndex, + fcFxPortFcphVersionAgreed + FcphVersion, + fcFxPortNxPortBbCredit + FcBbCredit, + fcFxPortNxPortRxDataFieldSize + FcRxDataFieldSize, + fcFxPortCosSuppAgreed + FcCosCap, + fcFxPortIntermixSuppAgreed + TruthValue, + fcFxPortStackedConnModeAgreed + FcStackedConnMode, + fcFxPortClass2SeqDelivAgreed + TruthValue, + fcFxPortClass3SeqDelivAgreed + TruthValue, + -- + fcFxPortNxPortName + FcNameId, + fcFxPortConnectedNxPort + FcAddressId, + fcFxPortBbCreditModel + FcBbCreditModel + } + + fcFxPortNxLoginIndex OBJECT-TYPE + SYNTAX FcFeNxPortIndex + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The object identifies the associated NxPort in the + attachment for which the entry contains information." + ::= { fcFxLoginEntry 1 } + + + + +Teow Standards Track [Page 21] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFxPortFcphVersionAgreed OBJECT-TYPE + SYNTAX FcphVersion + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of FC-PH that the FxPort has agreed to support + from the Fabric Login" + ::= { fcFxLoginEntry 2 } + + fcFxPortNxPortBbCredit OBJECT-TYPE + SYNTAX FcBbCredit + UNITS "buffers" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of buffers available for holding Class 1 + connect-request, Class 2 or Class 3 frames to be + transmitted to the attached NxPort. It is for buffer-to- + buffer flow control in the direction from FxPort to NxPort. + The buffer-to-buffer flow control mechanism is indicated in + the respective fcFxPortBbCreditModel." + ::= { fcFxLoginEntry 3 } + + fcFxPortNxPortRxDataFieldSize OBJECT-TYPE + SYNTAX FcRxDataFieldSize + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Receive Data Field Size of the attached NxPort. This + object specifies the largest Data Field Size for an FT_1 + frame that can be received by the NxPort." + ::= { fcFxLoginEntry 4 } + + fcFxPortCosSuppAgreed OBJECT-TYPE + SYNTAX FcCosCap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A variable indicating that the attached NxPort has + requested the FxPort for the support of classes of services + and the FxPort has granted the request." + ::= { fcFxLoginEntry 5 } + + fcFxPortIntermixSuppAgreed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + + + +Teow Standards Track [Page 22] + +RFC 2837 FC Fabric Element MIB May 2000 + + + DESCRIPTION + "A variable indicating that the attached NxPort has + requested the FxPort for the support of Intermix and the + FxPort has granted the request. This flag is only valid if + Class 1 service is supported." + ::= { fcFxLoginEntry 6 } + + fcFxPortStackedConnModeAgreed OBJECT-TYPE + SYNTAX FcStackedConnMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A variable indicating whether the FxPort has agreed to + support stacked connect from the Fabric Login. This is only + meaningful if Class 1 service has been agreed." + ::= { fcFxLoginEntry 7 } + + fcFxPortClass2SeqDelivAgreed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A variable indicating whether the FxPort has agreed to + support Class 2 sequential delivery from the Fabric Login. + This is only meaningful if Class 2 service has been + agreed." + ::= { fcFxLoginEntry 8 } + + fcFxPortClass3SeqDelivAgreed OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether the FxPort has agreed to support + Class 3 sequential delivery from the Fabric Login. This is + only meaningful if Class 3 service has been agreed." + ::= { fcFxLoginEntry 9 } + + fcFxPortNxPortName OBJECT-TYPE + SYNTAX FcNameId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The port name of the attached NxPort." + ::= { fcFxLoginEntry 10 } + + fcFxPortConnectedNxPort OBJECT-TYPE + SYNTAX FcAddressId + + + +Teow Standards Track [Page 23] + +RFC 2837 FC Fabric Element MIB May 2000 + + + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address identifier of the destination NxPort with which + this FxPort is currently engaged in a either a Class 1 or + loop connection. If this FxPort is not engaged in a + connection, then the value of this object is '000000'H." + ::= { fcFxLoginEntry 11 } + + fcFxPortBbCreditModel OBJECT-TYPE + SYNTAX FcBbCreditModel + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object identifies the BB_Credit model used by the + FxPort." + ::= { fcFxLoginEntry 12 } + + + -- the Error group + -- This group consists of tables that contain information about + -- the various types of errors detected. The management station + -- may use the information in this group to determine the + -- quality of the link between the FxPort and its attached NxPort. + + -- the FxPort Error table + -- This table contains, one entry for each FxPort in the Fabric + -- Element, counters recording numbers of errors detected + -- since the management agent re-initialized. + -- The first 6 columnar objects after the port index corresponds + -- to the counters in the Link Error Status Block. + + fcFxPortErrorTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortErrorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort, counters + that record the numbers of errors detected." + ::= { fcFeError 1 } + + fcFxPortErrorEntry OBJECT-TYPE + SYNTAX FcFxPortErrorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing error counters of a FxPort." + AUGMENTS { fcFxPortEntry } + + + +Teow Standards Track [Page 24] + +RFC 2837 FC Fabric Element MIB May 2000 + + + ::= { fcFxPortErrorTable 1 } + + + FcFxPortErrorEntry ::= + SEQUENCE { + fcFxPortLinkFailures + Counter32, + fcFxPortSyncLosses + Counter32, + fcFxPortSigLosses + Counter32, + fcFxPortPrimSeqProtoErrors + Counter32, + fcFxPortInvalidTxWords + Counter32, + fcFxPortInvalidCrcs + Counter32, + fcFxPortDelimiterErrors + Counter32, + fcFxPortAddressIdErrors + Counter32, + fcFxPortLinkResetIns + Counter32, + fcFxPortLinkResetOuts + Counter32, + fcFxPortOlsIns + Counter32, + fcFxPortOlsOuts + Counter32 + } + + fcFxPortLinkFailures OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of link failures detected by this FxPort." + ::= { fcFxPortErrorEntry 1 } + + fcFxPortSyncLosses OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of loss of synchronization detected by the + FxPort." + ::= { fcFxPortErrorEntry 2 } + + + + +Teow Standards Track [Page 25] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFxPortSigLosses OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of loss of signal detected by the FxPort." + ::= { fcFxPortErrorEntry 3 } + + fcFxPortPrimSeqProtoErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of primitive sequence protocol errors detected + by the FxPort." + ::= { fcFxPortErrorEntry 4 } + + fcFxPortInvalidTxWords OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of invalid transmission word detected by the + FxPort." + ::= { fcFxPortErrorEntry 5 } + + fcFxPortInvalidCrcs OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of invalid CRC detected by this FxPort." + ::= { fcFxPortErrorEntry 6 } + + fcFxPortDelimiterErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Delimiter Errors detected by this FxPort." + ::= { fcFxPortErrorEntry 7 } + + fcFxPortAddressIdErrors OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of address identifier errors detected by this + + + +Teow Standards Track [Page 26] + +RFC 2837 FC Fabric Element MIB May 2000 + + + FxPort." + ::= { fcFxPortErrorEntry 8 } + + fcFxPortLinkResetIns OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Link Reset Protocol received by this FxPort + from the attached NxPort." + ::= { fcFxPortErrorEntry 9 } + + fcFxPortLinkResetOuts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Link Reset Protocol issued by this FxPort to + the attached NxPort." + ::= { fcFxPortErrorEntry 10 } + + fcFxPortOlsIns OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Offline Sequence received by this FxPort." + ::= { fcFxPortErrorEntry 11 } + + fcFxPortOlsOuts OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Offline Sequence issued by this FxPort." + ::= { fcFxPortErrorEntry 12 } + + + + -- Accounting Groups: + -- (1) Class 1 Accounting Group, + -- (2) Class 2 Accounting Group, and + -- (3) Class 3 Accounting Group. + -- Each group consists of a table that contains accounting + -- information for the FxPorts in the Fabric Element. + + -- the Class 1 Accounting table + -- This table contains, one entry for each FxPort in the Fabric + + + +Teow Standards Track [Page 27] + +RFC 2837 FC Fabric Element MIB May 2000 + + + -- Element, Counter32s for certain types of events occurred in the + -- the FxPorts since the the management agent has re-initialized. + + fcFxPortC1AccountingTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortC1AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, Class 1 accounting information recorded + since the management agent has re-initialized." + ::= { fcFeAccounting 1 } + + fcFxPortC1AccountingEntry OBJECT-TYPE + SYNTAX FcFxPortC1AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing Class 1 accounting information for each + FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortC1AccountingTable 1 } + + + FcFxPortC1AccountingEntry ::= + SEQUENCE { + fcFxPortC1InFrames + Counter32, + fcFxPortC1OutFrames + Counter32, + fcFxPortC1InOctets + Counter32, + fcFxPortC1OutOctets + Counter32, + fcFxPortC1Discards + Counter32, + fcFxPortC1FbsyFrames + Counter32, + fcFxPortC1FrjtFrames + Counter32, + fcFxPortC1InConnections + Counter32, + fcFxPortC1OutConnections + Counter32, + fcFxPortC1ConnTime + MilliSeconds + } + + + + +Teow Standards Track [Page 28] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFxPortC1InFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 frames (other than Class 1 connect- + request) received by this FxPort from its attached NxPort." + ::= { fcFxPortC1AccountingEntry 1 } + + fcFxPortC1OutFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 frames (other than Class 1 connect- + request) delivered through this FxPort to its attached + NxPort." + ::= { fcFxPortC1AccountingEntry 2 } + + fcFxPortC1InOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 frame octets, including the frame + delimiters, received by this FxPort from its attached + NxPort." + ::= { fcFxPortC1AccountingEntry 3 } + + fcFxPortC1OutOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 frame octets, including the frame + delimiters, delivered through this FxPort its attached + NxPort." + ::= { fcFxPortC1AccountingEntry 4 } + + fcFxPortC1Discards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 frames discarded by this FxPort." + ::= { fcFxPortC1AccountingEntry 5 } + + fcFxPortC1FbsyFrames OBJECT-TYPE + + + +Teow Standards Track [Page 29] + +RFC 2837 FC Fabric Element MIB May 2000 + + + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of F_BSY frames generated by this FxPort against + Class 1 connect-request." + ::= { fcFxPortC1AccountingEntry 6 } + + fcFxPortC1FrjtFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of F_RJT frames generated by this FxPort against + Class 1 connect-request." + ::= { fcFxPortC1AccountingEntry 7 } + + fcFxPortC1InConnections OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 connections successfully established + in which the attached NxPort is the source of the connect- + request." + ::= { fcFxPortC1AccountingEntry 8 } + + fcFxPortC1OutConnections OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 1 connections successfully established + in which the attached NxPort is the destination of the + connect-request." + ::= { fcFxPortC1AccountingEntry 9 } + + fcFxPortC1ConnTime OBJECT-TYPE + SYNTAX MilliSeconds + UNITS "milliseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The cumulative time that this FxPort has been engaged in + Class 1 connection. The amount of time is counted from + after a connect-request has been accepted until the + connection is disengaged, either by an EOFdt or Link + Reset." + + + +Teow Standards Track [Page 30] + +RFC 2837 FC Fabric Element MIB May 2000 + + + ::= { fcFxPortC1AccountingEntry 10 } + + + -- the Class 2 Accounting table + -- This table contains, one entry for each FxPort in the Fabric + -- Element, Counter32s for certain types of events occurred in the + -- the FxPorts since the the management agent has re-initialized. + + + fcFxPortC2AccountingTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortC2AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, Class 2 accounting information recorded + since the management agent has re-initialized." + ::= { fcFeAccounting 2 } + + fcFxPortC2AccountingEntry OBJECT-TYPE + SYNTAX FcFxPortC2AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing Class 2 accounting information for each + FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortC2AccountingTable 1 } + + FcFxPortC2AccountingEntry ::= + SEQUENCE { + fcFxPortC2InFrames + Counter32, + fcFxPortC2OutFrames + Counter32, + fcFxPortC2InOctets + Counter32, + fcFxPortC2OutOctets + Counter32, + fcFxPortC2Discards + Counter32, + fcFxPortC2FbsyFrames + Counter32, + fcFxPortC2FrjtFrames + Counter32 + } + + fcFxPortC2InFrames OBJECT-TYPE + + + +Teow Standards Track [Page 31] + +RFC 2837 FC Fabric Element MIB May 2000 + + + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 2 frames received by this FxPort from + its attached NxPort." + ::= { fcFxPortC2AccountingEntry 1 } + + fcFxPortC2OutFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 2 frames delivered through this FxPort + to its attached NxPort." + ::= { fcFxPortC2AccountingEntry 2 } + + fcFxPortC2InOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 2 frame octets, including the frame + delimiters, received by this FxPort from its attached + NxPort." + ::= { fcFxPortC2AccountingEntry 3 } + + fcFxPortC2OutOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 2 frame octets, including the frame + delimiters, delivered through this FxPort to its attached + NxPort." + ::= { fcFxPortC2AccountingEntry 4 } + + fcFxPortC2Discards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 2 frames discarded by this FxPort." + ::= { fcFxPortC2AccountingEntry 5 } + + fcFxPortC2FbsyFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + + + +Teow Standards Track [Page 32] + +RFC 2837 FC Fabric Element MIB May 2000 + + + STATUS current + DESCRIPTION + "The number of F_BSY frames generated by this FxPort against + Class 2 frames." + ::= { fcFxPortC2AccountingEntry 6 } + + fcFxPortC2FrjtFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of F_RJT frames generated by this FxPort against + Class 2 frames." + ::= { fcFxPortC2AccountingEntry 7 } + + -- the Class 3 Accounting Group + -- This table contains, one entry for each FxPort in the Fabric + -- Element, Counter32s for certain types of events occurred in the + -- the FxPorts since the management agent has re-initialized. + + fcFxPortC3AccountingTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortC3AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort in the + Fabric Element, Class 3 accounting information recorded + since the management agent has re-initialized." + ::= { fcFeAccounting 3 } + + fcFxPortC3AccountingEntry OBJECT-TYPE + SYNTAX FcFxPortC3AccountingEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing Class 3 accounting information for each + FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortC3AccountingTable 1 } + + + FcFxPortC3AccountingEntry ::= + SEQUENCE { + fcFxPortC3InFrames + Counter32, + fcFxPortC3OutFrames + Counter32, + fcFxPortC3InOctets + + + +Teow Standards Track [Page 33] + +RFC 2837 FC Fabric Element MIB May 2000 + + + Counter32, + fcFxPortC3OutOctets + Counter32, + fcFxPortC3Discards + Counter32 + } + + fcFxPortC3InFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 3 frames received by this FxPort from + its attached NxPort." + ::= { fcFxPortC3AccountingEntry 1 } + + fcFxPortC3OutFrames OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 3 frames delivered through this FxPort + to its attached NxPort." + ::= { fcFxPortC3AccountingEntry 2 } + + fcFxPortC3InOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 3 frame octets, including the frame + delimiters, received by this FxPort from its attached + NxPort." + ::= { fcFxPortC3AccountingEntry 3 } + + fcFxPortC3OutOctets OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of Class 3 frame octets, including the frame + delimiters, delivered through this FxPort to its attached + NxPort." + ::= { fcFxPortC3AccountingEntry 4 } + + fcFxPortC3Discards OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + + + +Teow Standards Track [Page 34] + +RFC 2837 FC Fabric Element MIB May 2000 + + + STATUS current + DESCRIPTION + "The number of Class 3 frames discarded by this FxPort." + ::= { fcFxPortC3AccountingEntry 5 } + + + -- The Capability Group - consists of a table describing + -- information about what each FxPort is inherently capable + -- of operating or supporting. + -- A capability may be used, as expressed in its respective + -- object value in the Configuration group. + + fcFxPortCapTable OBJECT-TYPE + SYNTAX SEQUENCE OF FcFxPortCapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table that contains, one entry for each FxPort, the + capabilities of the port within the Fabric Element." + ::= { fcFeCapabilities 1 } + + fcFxPortCapEntry OBJECT-TYPE + SYNTAX FcFxPortCapEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the Cap of a FxPort." + AUGMENTS { fcFxPortEntry } + ::= { fcFxPortCapTable 1 } + + + FcFxPortCapEntry ::= + SEQUENCE { + fcFxPortCapFcphVersionHigh + FcphVersion, + fcFxPortCapFcphVersionLow + FcphVersion, + fcFxPortCapBbCreditMax + FcBbCredit, + fcFxPortCapBbCreditMin + FcBbCredit, + fcFxPortCapRxDataFieldSizeMax + FcRxDataFieldSize, + fcFxPortCapRxDataFieldSizeMin + FcRxDataFieldSize, + fcFxPortCapCos + FcCosCap, + fcFxPortCapIntermix + + + +Teow Standards Track [Page 35] + +RFC 2837 FC Fabric Element MIB May 2000 + + + TruthValue, + fcFxPortCapStackedConnMode + FcStackedConnMode, + fcFxPortCapClass2SeqDeliv + TruthValue, + fcFxPortCapClass3SeqDeliv + TruthValue, + fcFxPortCapHoldTimeMax + MicroSeconds, + fcFxPortCapHoldTimeMin + MicroSeconds + } + + fcFxPortCapFcphVersionHigh OBJECT-TYPE + SYNTAX FcphVersion + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The highest or most recent version of FC-PH that the FxPort + is capable of supporting." + ::= { fcFxPortCapEntry 1 } + + fcFxPortCapFcphVersionLow OBJECT-TYPE + SYNTAX FcphVersion + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The lowest or earliest version of FC-PH that the FxPort is + capable of supporting." + ::= { fcFxPortCapEntry 2 } + + fcFxPortCapBbCreditMax OBJECT-TYPE + SYNTAX FcBbCredit + UNITS "buffers" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of receive buffers available for holding + Class 1 connect-request, Class 2 or Class 3 frames from the + attached NxPort." + ::= { fcFxPortCapEntry 3 } + + fcFxPortCapBbCreditMin OBJECT-TYPE + SYNTAX FcBbCredit + UNITS "buffers" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + + + +Teow Standards Track [Page 36] + +RFC 2837 FC Fabric Element MIB May 2000 + + + "The minimum number of receive buffers available for holding + Class 1 connect-request, Class 2 or Class 3 frames from the + attached NxPort." + ::= { fcFxPortCapEntry 4 } + + fcFxPortCapRxDataFieldSizeMax OBJECT-TYPE + SYNTAX FcRxDataFieldSize + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum size in bytes of the Data Field in a frame that + the FxPort is capable of receiving from its attached + NxPort." + ::= { fcFxPortCapEntry 5 } + + fcFxPortCapRxDataFieldSizeMin OBJECT-TYPE + SYNTAX FcRxDataFieldSize + UNITS "bytes" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum size in bytes of the Data Field in a frame that + the FxPort is capable of receiving from its attached + NxPort." + ::= { fcFxPortCapEntry 6 } + + fcFxPortCapCos OBJECT-TYPE + SYNTAX FcCosCap + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value indicating the set of Classes of Service that the + FxPort is capable of supporting." + ::= { fcFxPortCapEntry 7 } + + fcFxPortCapIntermix OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not the FxPort is capable of + supporting the intermixing of Class 2 and Class 3 frames + during a Class 1 connection. This flag is only valid if the + port is capable of supporting Class 1 service." + ::= { fcFxPortCapEntry 8 } + + fcFxPortCapStackedConnMode OBJECT-TYPE + + + +Teow Standards Track [Page 37] + +RFC 2837 FC Fabric Element MIB May 2000 + + + SYNTAX FcStackedConnMode + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A value indicating the mode of Stacked Connect request that + the FxPort is capable of supporting." + ::= { fcFxPortCapEntry 9 } + + fcFxPortCapClass2SeqDeliv OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not the FxPort is capable of + supporting Class 2 Sequential Delivery." + ::= { fcFxPortCapEntry 10 } + + fcFxPortCapClass3SeqDeliv OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A flag indicating whether or not the FxPort is capable of + supporting Class 3 Sequential Delivery." + ::= { fcFxPortCapEntry 11 } + + fcFxPortCapHoldTimeMax OBJECT-TYPE + SYNTAX MicroSeconds + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum holding time (in microseconds) that the FxPort + is capable of supporting." + ::= { fcFxPortCapEntry 12 } + + fcFxPortCapHoldTimeMin OBJECT-TYPE + SYNTAX MicroSeconds + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum holding time (in microseconds) that the FxPort + is capable of supporting." + ::= { fcFxPortCapEntry 13 } + + -- conformance information + + + + +Teow Standards Track [Page 38] + +RFC 2837 FC Fabric Element MIB May 2000 + + + fcFeMIBConformance OBJECT IDENTIFIER ::= { fcFeMIB 2 } + fcFeMIBCompliances OBJECT IDENTIFIER ::= { fcFeMIBConformance 1 } + fcFeMIBGroups OBJECT IDENTIFIER ::= { fcFeMIBConformance 2 } + + -- compliance statements + fcFeMIBMinimumCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The minimum compliance statement for SNMP entities + which implement the FIBRE-CHANNEL-FE-MIB." + MODULE -- this module + MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup, + fcFeErrorGroup } + + OBJECT fcFeFabricName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFeElementName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFeModuleName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortAdminMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortPhysAdminStatus + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortPhysRttov + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortBbCreditModel + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + + +Teow Standards Track [Page 39] + +RFC 2837 FC Fabric Element MIB May 2000 + + + ::= { fcFeMIBCompliances 1 } + + fcFeMIBFullCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The full compliance statement for SNMP entities + which implement the FIBRE-CHANNEL-FE-MIB." + MODULE -- this module + MANDATORY-GROUPS { fcFeConfigGroup, fcFeStatusGroup, + fcFeErrorGroup, fcFeCapabilitiesGroup } + + GROUP fcFeClass1AccountingGroup + DESCRIPTION + "This group is mandatory for all fibre channel fabric + elements which support class 1 frames." + + GROUP fcFeClass2AccountingGroup + DESCRIPTION + "This group is mandatory for all fibre channel fabric + elements which support class 2 frames." + + GROUP fcFeClass3AccountingGroup + DESCRIPTION + "This group is mandatory for all fibre channel fabric + elements which support class 3 frames." + + OBJECT fcFeFabricName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFeElementName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFeModuleName + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortAdminMode + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortPhysAdminStatus + MIN-ACCESS read-only + + + +Teow Standards Track [Page 40] + +RFC 2837 FC Fabric Element MIB May 2000 + + + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortPhysRttov + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + OBJECT fcFxPortBbCreditModel + MIN-ACCESS read-only + DESCRIPTION + "Write access is not required." + + ::= { fcFeMIBCompliances 2 } + + -- units of conformance + fcFeConfigGroup OBJECT-GROUP + OBJECTS { fcFeFabricName, fcFeElementName, fcFeModuleCapacity, + fcFeModuleDescr, fcFeModuleObjectID, + fcFeModuleOperStatus, fcFeModuleLastChange, + fcFeModuleFxPortCapacity, fcFeModuleName, + fcFxPortName, fcFxPortFcphVersionHigh, + fcFxPortFcphVersionLow, fcFxPortBbCredit, + fcFxPortRxBufSize, fcFxPortRatov, fcFxPortEdtov, + fcFxPortCosSupported, fcFxPortIntermixSupported, + fcFxPortStackedConnMode, fcFxPortClass2SeqDeliv, + fcFxPortClass3SeqDeliv, fcFxPortHoldTime } + STATUS current + DESCRIPTION + "A collection of objects providing the configuration and service + parameters of the Fabric Element, the modules, and FxPorts." + ::= { fcFeMIBGroups 1 } + + fcFeStatusGroup OBJECT-GROUP + OBJECTS { fcFxPortID, fcFxPortBbCreditAvailable, + fcFxPortOperMode, fcFxPortAdminMode, + fcFxPortPhysAdminStatus, fcFxPortPhysOperStatus, + fcFxPortPhysLastChange, fcFxPortPhysRttov, + fcFxPortFcphVersionAgreed, fcFxPortNxPortBbCredit, + fcFxPortNxPortRxDataFieldSize, fcFxPortCosSuppAgreed, + fcFxPortIntermixSuppAgreed, + fcFxPortStackedConnModeAgreed, + fcFxPortClass2SeqDelivAgreed, + fcFxPortClass3SeqDelivAgreed, + fcFxPortNxPortName, fcFxPortConnectedNxPort, + fcFxPortBbCreditModel } + STATUS current + DESCRIPTION + + + +Teow Standards Track [Page 41] + +RFC 2837 FC Fabric Element MIB May 2000 + + + "A collection of objects providing the operational status and + established service parameters for the Fabric Element and the + attached NxPorts." + ::= { fcFeMIBGroups 2 } + + fcFeErrorGroup OBJECT-GROUP + OBJECTS { fcFxPortLinkFailures, fcFxPortSyncLosses, + fcFxPortSigLosses, fcFxPortPrimSeqProtoErrors, + fcFxPortInvalidTxWords, fcFxPortInvalidCrcs, + fcFxPortDelimiterErrors, fcFxPortAddressIdErrors, + fcFxPortLinkResetIns, fcFxPortLinkResetOuts, + fcFxPortOlsIns, fcFxPortOlsOuts } + STATUS current + DESCRIPTION + "A collection of objects providing various error + statistics detected by the FxPorts." + ::= { fcFeMIBGroups 3 } + + fcFeClass1AccountingGroup OBJECT-GROUP + OBJECTS { fcFxPortC1InFrames, fcFxPortC1OutFrames, + fcFxPortC1InOctets, fcFxPortC1OutOctets, + fcFxPortC1Discards, fcFxPortC1FbsyFrames, + fcFxPortC1FrjtFrames, fcFxPortC1InConnections, + fcFxPortC1OutConnections, fcFxPortC1ConnTime + } + STATUS current + DESCRIPTION + "A collection of objects providing various class 1 + performance statistics detected by the FxPorts." + ::= { fcFeMIBGroups 4 } + + fcFeClass2AccountingGroup OBJECT-GROUP + OBJECTS { fcFxPortC2InFrames, fcFxPortC2OutFrames, + fcFxPortC2InOctets, fcFxPortC2OutOctets, + fcFxPortC2Discards, fcFxPortC2FbsyFrames, + fcFxPortC2FrjtFrames + } + STATUS current + DESCRIPTION + "A collection of objects providing various class 2 + performance statistics detected by the FxPorts." + ::= { fcFeMIBGroups 5 } + + fcFeClass3AccountingGroup OBJECT-GROUP + OBJECTS { fcFxPortC3InFrames, fcFxPortC3OutFrames, + fcFxPortC3InOctets, fcFxPortC3OutOctets, + fcFxPortC3Discards + } + + + +Teow Standards Track [Page 42] + +RFC 2837 FC Fabric Element MIB May 2000 + + + STATUS current + DESCRIPTION + "A collection of objects providing various class 3 + performance statistics detected by the FxPorts." + ::= { fcFeMIBGroups 6 } + + fcFeCapabilitiesGroup OBJECT-GROUP + OBJECTS { fcFxPortCapFcphVersionHigh, fcFxPortCapFcphVersionLow, + fcFxPortCapBbCreditMax, fcFxPortCapBbCreditMin, + fcFxPortCapRxDataFieldSizeMax, + fcFxPortCapRxDataFieldSizeMin, + fcFxPortCapCos, fcFxPortCapIntermix, + fcFxPortCapStackedConnMode, fcFxPortCapClass2SeqDeliv, + fcFxPortCapClass3SeqDeliv, fcFxPortCapHoldTimeMax, + fcFxPortCapHoldTimeMin + } + STATUS current + DESCRIPTION + "A collection of objects providing the inherent + capability of each FxPort within the Fabric Element." + ::= { fcFeMIBGroups 7 } + + + END + -- End of Object Definitions + +4. Security Considerations + + There are a number of management objects defined in this MIB that + have a MAX-ACCESS clause of read-write. Such objects may be + considered sensitive or vulnerable in some network environments. The + support for SET operations in a non-secure environment without proper + protection can have a negative effect on network operations. + + SNMPv1 by itself is not a secure environment. Even if the network + itself is secure (for example by using IPSec), even then, there is no + control as to who on the secure network is allowed to access and + GET/SET (read/change/create/delete) the objects in this MIB. + + It is recommended that the implementers consider the security + features as provided by the SNMPv3 framework. Specifically, the use + of the User-based Security Model RFC 2574 [12] and the View-based + Access Control Model RFC 2575 [15] is recommended. + + + + + + + + +Teow Standards Track [Page 43] + +RFC 2837 FC Fabric Element MIB May 2000 + + + It is then a customer/user responsibility to ensure that the SNMP + entity giving access to an instance of this MIB, is properly + configured to give access to the objects only to those principals + (users) that have legitimate rights to indeed GET or SET + (change/delete) them. + +5. Intellectual Property + + The IETF takes no position regarding the validity or scope of any + intellectual property or other rights that might be claimed to + pertain to the implementation or use of the technology described in + this document or the extent to which any license under such rights + might or might not be available; neither does it represent that it + has made any effort to identify any such rights. Information on the + IETF's procedures with respect to rights in standards-track and + standards-related documentation can be found in BCP-11. Copies of + claims of rights made available for publication and any assurances of + licenses to be made available, or the result of an attempt made to + obtain a general license or permission for the use of such + proprietary rights by implementors or users of this specification can + be obtained from the IETF Secretariat. + + The IETF invites any interested party to bring to its attention any + copyrights, patents or patent applications, or other proprietary + rights which may cover technology that may be required to practice + this standard. Please address the information to the IETF Executive + Director. + +6. Acknowledgements + + The editors would like to thank the following individuals for their + assistance and constructive comments: + + Juergen Schoenwaelder, Technical University Braunschweig + Vincent Guan, Brocade Gavin Bowlby, Gadzoox + Bent Stoevhase, Brocade Jeff Meyer, HP + John Y. Chu, IBM + Yakov Rekhter, Cisco Martin Sachs, IBM + Dan Eisenhauer, IBM Beth Vanderbeck, IBM + Carl Zeitler, Compaq Paul Griffiths, IBM + KC Chennappan, IBM Jessie Haug, IBM + Bob Cornelius, ANCOR Lansing Sloan, LLNL + Paul Rupert, LLNL Rich Taborak, NSerial + Steve Wilson, Brocade Jerry Rouse, IBM + Dal Allan, ENDL Hubert Huot, IBM + Venkat Rao, HP Amir Artsi, RADWAY International Ltd. + + + + + +Teow Standards Track [Page 44] + +RFC 2837 FC Fabric Element MIB May 2000 + + +7. References + +7.1. IETF References + + [1] Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for + Describing SNMP Management Frameworks", RFC 2571, April 1999. + + [2] Rose, M. and K. McCloghrie, "Structure and Identification of + Management Information for TCP/IP-based Internets", STD 16, RFC + 1155, May 1990. + + [3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16, + RFC 1212, March 1991. + + [4] Rose, M., "A Convention for Defining Traps for use with the + SNMP", RFC 1215, March 1991. + + [5] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, + M. and S. Waldbusser, "Structure of Management Information + Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. + + [6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, + M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58, + RFC 2579, April 1999. + + [7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, + M. and S. Waldbusser, "Conformance Statements for SMIv2", STD + 58, RFC 2580, April 1999. + + [8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple + Network Management Protocol", STD 15, RFC 1157, May 1990. + + [9] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, + "Introduction to Community-based SNMPv2", RFC 1901, January + 1996. + + [10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport + Mappings for Version 2 of the Simple Network Management Protocol + (SNMPv2)", RFC 1906, January 1996. + + [11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message + Processing and Dispatching for the Simple Network Management + Protocol (SNMP)", RFC 2572, April 1999. + + [12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM) + for version 3 of the Simple Network Management Protocol + (SNMPv3)", RFC 2574, April 1999. + + + + +Teow Standards Track [Page 45] + +RFC 2837 FC Fabric Element MIB May 2000 + + + [13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol + Operations for Version 2 of the Simple Network Management + Protocol (SNMPv2)", RFC 1905, January 1996. + + [14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC + 2573, April 1999. + + [15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access + Control Model (VACM) for the Simple Network Management Protocol + (SNMP)", RFC 2575, April 1999. + + [16] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction + to Version 3 of the Internet-standard Network Management + Framework", RFC 2570, April 1999. + +7.2. Approved ANSI/NCITS References + + [17] Fibre Channel Physical and Signaling Interface (FC-PH), American + National Standard for Information Systems X3.230:1994, Computer + and Business Equipment Manufacturers Association, Washington, + DC. + + [18] Fibre Channel Fabric Generic (FC-FG), American National Standard + for Information Systems X3.289:1996, Computer and Business + Equipment Manufacturers Association, Washington, DC. + + [19] Fibre Channel Generic Services (FC-GS), American National + Standard for Information Systems X3.288:1996, Computer and + Business Equipment Manufacturers Association, Washington, DC. + + [20] Fibre Channel Arbitrated Loop (FC-AL), American National + Standard for Information Systems X3.272:1996, Computer and + Business Equipment Manufacturers Association, Washington, DC. + + [21] Fibre Channel Physical and Signaling Interface-2 (FC-PH-2), + American National Standard for Information Systems, X3.297:1997, + Computer and Business Equipment Manufacturers Association, + Washington, DC. + + [22] Fibre Channel Physical and Signaling Interface-3 (FC-PH-3), + American National Standard for Information Systems, X3.303:1998, + Computer and Business Equipment Manufacturers Association, + Washington, DC. + + [23] Fibre Channel Switch Fabric (FC-SW), American National Standard + for Information Systems, NCITS 321:1998, Computer and Business + Equipment Manufacturers Association, Washington, DC. + + + + +Teow Standards Track [Page 46] + +RFC 2837 FC Fabric Element MIB May 2000 + + +7.3. ANSI/NCITS References Under Development + + [24] Fibre Channel Arbitrated Loop-2 (FC-AL-2), American National + Standard for Information Systems, X3T11/1133D Rev 5.2, Computer + and Business Equipment Manufacturers Association, Washington, + DC. + +8. Editor's Address + + Kha Sin Teow + Brocade Communications Systems, Inc. + 1901 Guadalupe Parkway, + San Jose, CA 95131 + U.S.A. + + Phone: +1 408-487-8180 + Email: khasin@Brocade.COM + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +Teow Standards Track [Page 47] + +RFC 2837 FC Fabric Element MIB May 2000 + + +9. Full Copyright Statement + + Copyright (C) The Internet Society (2000). All Rights Reserved. + + This document and translations of it may be copied and furnished to + others, and derivative works that comment on or otherwise explain it + or assist in its implementation may be prepared, copied, published + and distributed, in whole or in part, without restriction of any + kind, provided that the above copyright notice and this paragraph are + included on all such copies and derivative works. However, this + document itself may not be modified in any way, such as by removing + the copyright notice or references to the Internet Society or other + Internet organizations, except as needed for the purpose of + developing Internet standards in which case the procedures for + copyrights defined in the Internet Standards process must be + followed, or as required to translate it into languages other than + English. + + The limited permissions granted above are perpetual and will not be + revoked by the Internet Society or its successors or assigns. + + This document and the information contained herein is provided on an + "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING + TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING + BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION + HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF + MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. + +Acknowledgement + + Funding for the RFC Editor function is currently provided by the + Internet Society. + + + + + + + + + + + + + + + + + + + +Teow Standards Track [Page 48] + |