1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
|
Network Working Group D. McMaster
Request for Comments: 1368 SynOptics Communications, Inc.
K. McCloghrie
Hughes LAN Systems, Inc.
October 1992
Definitions of Managed Objects for IEEE 802.3 Repeater Devices
Status of this Memo
This RFC specifies an IAB standards track protocol for the Internet
community, and requests discussion and suggestions for improvements.
Please refer to the current edition of the "IAB Official Protocol
Standards" for the standardization state and status of this protocol.
Distribution of this memo is unlimited.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP-based internets.
In particular, it defines objects for managing IEEE 802.3 10
Mb/second baseband repeaters, sometimes referred to as "hubs."
Table of Contents
1. Management Framework ........................................ 2
2. Objects ..................................................... 2
2.1 Format of Definitions ...................................... 3
3. Overview .................................................... 3
3.1 Terminology ................................................ 3
3.1.1 Repeaters, Hubs and Concentrators ........................ 3
3.1.2 Repeaters, Ports, and MAUs ............................... 4
3.1.3 Ports and Groups ......................................... 6
3.2 Supporting Functions ....................................... 7
3.3 Structure of MIB ........................................... 9
3.3.1 The Basic Group Definitions .............................. 10
3.3.2 The Monitor Group Definitions ............................ 10
3.3.3 The Address Tracking Group Definitions ................... 10
3.4 Relationship to Other MIBs ................................. 10
3.4.1 Relationship to the 'system' group ....................... 10
3.4.2 Relationship to the 'interfaces' group .................... 10
3.5 Textual Conventions ........................................ 11
4. Definitions ................................................. 11
4.1 MIB Groups in the Repeater MIB ............................. 12
4.2 The Basic Group Definitions ................................ 13
4.3 The Monitor Group Definitions .............................. 23
4.4 The Address Tracking Group Definitions ..................... 33
McMaster & McCloghrie [Page 1]
^L
RFC 1368 802.3 Repeater MIB October 1992
4.5 Traps for use by Repeaters ................................. 35
5. Acknowledgments ............................................. 37
6. References .................................................. 39
7. Security Considerations...................................... 40
8. Authors' Addresses........................................... 40
1. Management Framework
The Internet-standard Network Management Framework consists of three
components. They are:
STD 16/RFC 1155 [1] which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of management. STD
16/RFC 1212 [7] defines a more concise description mechanism,
which is wholly consistent with the SMI.
RFC 1156 [2] which defines MIB-I, the core set of managed objects
for the Internet suite of protocols. STD 17/RFC 1213 [4] defines
MIB-II, an evolution of MIB-I based on implementation experience
and new operational requirements.
STD 15/RFC 1157 [3] which defines the SNMP, the protocol used for
network access to managed objects.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
2. Objects
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1) [5]
defined in the SMI. In particular, each object has a name, a syntax,
and an encoding. The name is an object identifier, an
administratively assigned name, which specifies an object type. The
object type together with an object instance serves to uniquely
identify a specific instantiation of the object. For human
convenience, we often use a textual string, termed the OBJECT
DESCRIPTOR, to also refer to the object type.
The syntax of an object type defines the abstract data structure
corresponding to that object type. The ASN.1 language is used for
this purpose. However, the SMI [1] purposely restricts the ASN.1
constructs which may be used. These restrictions are explicitly made
for simplicity.
The encoding of an object type is simply how that object type is
represented using the object type's syntax. Implicitly tied to the
McMaster & McCloghrie [Page 2]
^L
RFC 1368 802.3 Repeater MIB October 1992
notion of an object type's syntax and encoding is how the object type
is represented when being transmitted on the network.
The SMI specifies the use of the basic encoding rules of ASN.1 [6],
subject to the additional requirements imposed by the SNMP.
2.1. Format of Definitions
Section 4 contains the specification of all object types contained in
this MIB module. The object types are defined using the conventions
defined in the SMI, as amended by the extensions specified in [7,8].
3. Overview
Instances of the object types defined in this memo represent
attributes of an IEEE 802.3 (Ethernet-like) repeater, as defined by
Section 9, "Repeater Unit for 10 Mb/s Baseband Networks" in the IEEE
802.3/ISO 8802-3 CSMA/CD standard [9].
These Repeater MIB objects may be used to manage non-standard
repeater-like devices, but defining objects to describe
implementation-specific properties of non-standard repeater-like
devices is outside the scope of this memo.
The definitions presented here are based on the IEEE draft standard
P802.3K, "Layer Management for 10 Mb/s Baseband Repeaters." [10]
Implementors of these MIB objects should note that [10] explicitly
describes when, where, and how various repeater attributes are
measured. The IEEE document also describes the effects of repeater
actions that may be invoked by manipulating instances of the MIB
objects defined here.
The counters in this document are defined to be the same as those
counters in the IEEE 802.3 Repeater Management draft, with the
intention that a single instrumentation can be used to implement both
the IEEE and IETF management standards.
3.1. Terminology
3.1.1. Repeaters, Hubs and Concentrators
In late 1988, the IEEE 802.3 Hub Management task force was chartered
to define managed objects for both 802.3 repeaters and the proposed
10BASE-FA synchronous active stars. The term "hub" was used to cover
both repeaters and active stars.
In March, 1991, the active star proposal was dropped from the
10BASE-F draft. Subsequently the 802.3 group changed the name of the
McMaster & McCloghrie [Page 3]
^L
RFC 1368 802.3 Repeater MIB October 1992
task force to be the IEEE 802.3 Repeater Management Task Force, and
likewise renamed their draft.
The use of the term "hub" has led to some confusion, as the terms
"hub," "intelligent hub," and "concentrator" are often used to
indicate a modular chassis with plug-in modules that provide
generalized LAN/WAN connectivity, often with a mix of 802.3 repeater,
token ring, and FDDI connectivity, internetworked by bridges,
routers, and terminal servers.
To be clear that this work covers the management of IEEE 802.3
repeaters only, the editors of this MIB definitions document chose to
call this a "Repeater MIB" instead of a "Hub MIB."
3.1.2. Repeaters, Ports, and MAUs
The following text roughly defines the terms "repeater," "port," and
"MAU" as used in the context of this memo. This text is imprecise
and omits many technical details. For a more complete and precise
definition of these terms, refer to Section 9 of [9].
An IEEE 802.3 repeater connects "Ethernet-like" media segments
together to extend the network length and topology beyond what can be
achieved with a single coax segment. It can be pictured as a star
structure with two or more input/output ports. The diagram below
illustrates a 6-port repeater:
^ ^
| |
\ \ / /
\ \ / /
_____\ v /_____
-> ______ ______ ->
/ ^ \
/ / \ \
/ / \ \
| |
v v
Figure 1. Repeater Unit
All the stations on the media segments connected to a given
repeater's ports participate in a single collision domain. A packet
transmitted by any of these stations is seen by all of these
stations.
Data coming in on any port in the repeater is transmitted out through
McMaster & McCloghrie [Page 4]
^L
RFC 1368 802.3 Repeater MIB October 1992
each of the remaining n-1 ports. If data comes in to the repeater on
two or more ports simultaneously or the repeater detects a collision
on the incoming port, the repeater transmits a jamming signal out on
all ports for the duration of the collision.
A repeater is a bit-wise store-and-forward device. It is
differentiated from a bridge (a frame store-and-forward device) in
that it is primarily concerned with carrier sense and data bits, and
does not make data-handling decisions based on the legality or
contents of a packet. A repeater retransmits data bits as they are
received. Its data FIFO holds only enough bits to make sure that the
FIFO does not underflow when the data rate of incoming bits is
slightly slower than the repeater's transmission rate.
A repeater is not an end-station on the network, and does not count
toward the overall limit of 1024 stations. A repeater has no MAC
address associated with it, and therefore packets may not be
addressed to the repeater or to its ports. (Packets may be addressed
to the MAC address of a management entity that is monitoring a
repeater. This management entity may or may not be connected to the
network through one of the repeater's ports. How the management
entity obtains information about the activity on the repeater is an
implementation issue, and is not discussed in this memo.)
A repeater is connected to the network with Medium Attachment Units
(MAUs), and sometimes through Attachment Unit Interfaces (AUIs) as
well. ("MAUs" are also known as transceivers, and an "AUI" is the
same as a 15-pin Ethernet or DIX connector.)
The 802.3 standard defines a "repeater set" as the "repeater unit"
plus its associated MAUs (and AUIs if present). The "repeater unit"
is defined as the portion of the repeater set that is inboard of the
physical media interfaces. The MAUs may be physically separate from
the repeater unit, or they may be integrated into the same physical
package.
(MAU) (MAU)
\ \ / /
\ \ / /
_____\ v /_____
(MAU) ______ ______ (MAU)
/ ^ \
/ / \ \
/ / \ \
(MAU) (MAU)
Figure 2. Repeater Set
McMaster & McCloghrie [Page 5]
^L
RFC 1368 802.3 Repeater MIB October 1992
The most commonly-used MAUs are the 10BASE-5 (AUI to thick "yellow"
coax), 10BASE-2 (BNC to thin coax), 10BASE-T (unshielded twisted-
pair), and FOIRL (asynchronous fiber optic inter-repeater link, which
is being combined into the 10BASE-F standard as 10BASE-FL). The
draft 10BASE-F standard also includes the definition for a new
synchronous fiber optic attachment, known as 10BASE-FB.
It should be stressed that the repeater MIB being defined by the IEEE
covers only the repeater unit management - it does not include
management of the MAUs that form the repeater set. The IEEE
recognizes that MAU management should be the same for MAUs connected
to end-stations (DTEs) as it is for MAUs connected to repeaters.
This memo follows the same strategy; the definition of management
information for MAUs is being addressed in a separate memo.
3.1.3. Ports and Groups
Repeaters are often implemented in modular "concentrators," where a
card cage holds several field-replaceable cards. Several cards may
form a single repeater unit, with each card containing one or more of
the repeater's ports. Because of this modular architecture, users
typically identify these repeater ports with a card number plus the
port number relative to the card, e.g., Card 3, Port 11.
To support this modular numbering scheme, this document follows the
example of the IEEE Repeater Management draft [10], allowing an
implementor to separate the ports in a repeater into "groups", if
desired. For example, an implementor might choose to represent
field-replaceable units as groups of ports so that the port numbering
would match the modular hardware implementation.
This group mapping is recommended but optional. An implementor may
choose to put all of a modular repeater's ports into a single group,
or to divide the ports into groups that do not match physical
divisions.
The object rptrGroupCapacity, which has a maximum value of 1024,
indicates the maximum number of groups that a given repeater may
contain. The value of rptrGroupCapacity must remain constant from
one management restart to the next.
Each group within the repeater is uniquely identified by a group
number in the range 1..rptrGroupCapacity. Groups may come and go
without causing a management reset, and may be sparsely numbered
within the repeater. For example, in a 12-card cage, cards 3, 5, 6,
and 7 may together form a single repeater, and the implementor may
choose to number them as groups 3, 5, 6, and 7, respectively.
McMaster & McCloghrie [Page 6]
^L
RFC 1368 802.3 Repeater MIB October 1992
The object rptrGroupPortCapacity, which also has a maximum value of
1024, indicates the maximum number of ports that a given group may
contain. The value of rptrGroupPortCapacity must not change for a
given group. However, a group may be deleted from the repeater and
replaced with a group containing a different number of ports. The
value of rptrGroupLastOperStatusChange will indicate that a change
took place.
Each port within the repeater is uniquely identified by a combination
of group number and port number, where port number is an integer in
the range 1..rptrGroupPortCapacity. As with groups within a
repeater, ports within a group may be sparsely numbered. Likewise,
ports may come and go within a group without causing a management
reset.
3.2. Supporting Functions
The IEEE 802.3 Hub Management draft [10] defines the following seven
functions and seven signals used to describe precisely when port
counters are incremented. The relationship between the functions and
signals is shown in Figure 3.
The CollisionEvent, ActivityDuration, CarrierEvent, FramingError,
OctetCount, FCSError, and SourceAddress output signals defined here
are not retrievable MIB objects, but rather are concepts used in
defining the MIB objects. The inputs are defined in Section 9 of the
IEEE 802.3 standard [9].
McMaster & McCloghrie [Page 7]
^L
RFC 1368 802.3 Repeater MIB October 1992
+---------+
|Collision|--------------------->CollisionEvent
CollIn(X)+>|Event |
| |Funct | +--------+
| +---------+ |Activity|
| +-------+ |Timing |->ActivityDuration
+>|Carrier| +---->|Funct |
|Event | | +--------+
DataIn(X)->|Funct |+-----+---------------->CarrierEvent
+-------+|
| +-------+
+>|Framing|------------>FramingError
|Funct | +-------+
decodedData---------->| |+>|Octet |
+-------+| |Count |->OctetCount
| |Funct |
| +-------+
| +-------+
Octet | |Cyclic |
Stream +>|Redund.|
| |Check |->FCSError
| |Funct |
| +-------+
| +-------+
| |Source |
+>|Address|->SourceAddress
|Funct |
+-------+
Figure 3. Port Functions Relationship
Collision Event Function: The collision event function asserts the
CollisionEvent signal when the CollIn(X) variable has the value SQE.
The CollisionEvent signal remains asserted until the assertion of any
CarrierEvent signal due to the reception of the following event.
Carrier Event Function: The carrier event function asserts the
CarrierEvent signal when the repeater exits the IDLE state, Fig 9-2
[9], and the port has been determined to be port N. It deasserts the
CarrierEvent signal when, for a duration of at least Carrier Recovery
Time (Ref: 9.5.6.5 [9]), both the DataIn(N) variable has the value II
and the CollIn(N) variable has the value -SQE. The value N is the
port assigned at the time of transition from the IDLE state.
Framing Function: The framing function recognizes the boundaries of
an incoming frame by monitoring the CarrierEvent signal and the
decoded data stream. Data bits are accepted while the CarrierEvent
McMaster & McCloghrie [Page 8]
^L
RFC 1368 802.3 Repeater MIB October 1992
signal is asserted. The framing function strips preamble and start
of frame delimiter from the received data stream. The remaining bits
are aligned along octet boundaries. If there is not an integral
number of octets, then FramingError shall be asserted. The
FramingError signal is cleared upon the assertion of the CarrierEvent
signal due to the reception of the following event.
Activity Timing Function: The activity timing function measures the
duration of the assertion of the CarrierEvent signal. This duration
value must be adjusted by removing the value of Carrier Recovery Time
(Ref: 9.5.6.5 [9]) to obtain the true duration of activity on the
network. The output of the Activity Timing function is the
ActivityDuration value, which represents the duration of the
CarrierEvent signal as expressed in units of bit times.
Octet Counting Function: The octet counting function counts the
number of complete octets received from the output of the framing
function. The output of the octet counting function is the
OctetCount value. The OctetCount value is reset to zero upon the
assertion of the CarrierEvent signal due to the reception of the
following event.
Cyclic Redundancy Check Function: The cyclic redundancy check
function verifies that the sequence of octets output by the framing
function contains a valid frame check sequence field. The frame
check sequence field is the last four octets received from the output
of the framing function. The algorithm for generating an FCS from
the octet stream is specified in 3.2.8 [9]. If the FCS generated
according to this algorithm is not the same as the last four octets
received from the framing function then the FCSError signal is
asserted. The FCSError signal is cleared upon the assertion of the
CarrierEvent signal due to the reception of the following event.
Source Address Function: The source address function extracts octets
from the stream output by the framing function. The seventh through
twelfth octets shall be extracted from the octet stream and output as
the SourceAddress variable. The SourceAddress variable is set to an
invalid state upon the assertion of the CarrierEvent signal due to
the reception of the following event.
3.3. Structure of MIB
Objects in this MIB are arranged into MIB groups. Each MIB group is
organized as a set of related objects.
McMaster & McCloghrie [Page 9]
^L
RFC 1368 802.3 Repeater MIB October 1992
3.3.1. The Basic Group Definitions
This mandatory group contains the objects which are applicable to all
repeaters. It contains status, parameter and control objects for the
repeater as a whole, the port groups within the repeater, as well as
for the individual ports themselves.
3.3.2. The Monitor Group Definitions
This optional group contains monitoring statistics for the repeater
as a whole and for individual ports.
3.3.3. The Address Tracking Group Definitions
This optional group contains objects for tracking the MAC addresses
of the DTEs attached to the ports of the repeater.
3.4. Relationship to Other MIBs
It is assumed that a repeater implementing this MIB will also
implement (at least) the 'system' group defined in MIB-II [4].
3.4.1. Relationship to the 'system' group
In MIB-II, the 'system' group is defined as being mandatory for all
systems such that each managed entity contains one instance of each
object in the 'system' group. Thus, those objects apply to the
entity even if the entity's sole functionality is management of a
repeater.
3.4.2. Relationship to the 'interfaces' group
In MIB-II, the 'interfaces' group is defined as being mandatory for
all systems and contains information on an entity's interfaces, where
each interface is thought of as being attached to a 'subnetwork'.
(Note that this term is not to be confused with 'subnet' which refers
to an addressing partitioning scheme used in the Internet suite of
protocols.)
This Repeater MIB uses the notion of ports on a repeater. The
concept of a MIB-II interface has NO specific relationship to a
repeater's port. Therefore, the 'interfaces' group applies only to
the one (or more) network interfaces on which the entity managing the
repeater sends and receives management protocol operations, and does
not apply to the repeater's ports.
This is consistent with the physical-layer nature of a repeater. A
repeater is a bitwise store-and-forward device. It recognizes
McMaster & McCloghrie [Page 10]
^L
RFC 1368 802.3 Repeater MIB October 1992
activity and bits, but does not process incoming data based on any
packet-related information (such as checksum or addresses). A
repeater has no MAC address, no MAC implementation, and does not pass
packets up to higher-level protocol entities for processing.
(When a network management entity is observing the repeater, it may
appear as though the repeater is passing packets to a higher-level
protocol entity. However, this is only a means of implementing
management, and this passing of management information is not part of
the repeater functionality.)
3.5. Textual Conventions
The datatype MacAddress is used as a textual convention in this
document. This textual convention has NO effect on either the syntax
nor the semantics of any managed object. Objects defined using this
convention are always encoded by means of the rules that define their
primitive type. Hence, no changes to the SMI or the SNMP are
necessary to accommodate this textual convention which is adopted
merely for the convenience of readers.
4. Definitions
SNMP-REPEATER-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, TimeTicks, Gauge
FROM RFC1155-SMI
mib-2, DisplayString FROM RFC1213-MIB
TRAP-TYPE FROM RFC-1215
OBJECT-TYPE FROM RFC-1212;
snmpDot3RptrMgt OBJECT IDENTIFIER ::= { mib-2 22 }
-- All representations of MAC addresses in this MIB Module use,
-- as a textual convention (i.e., this convention does not affect
-- their encoding), the data type:
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address in
-- the "canonical" order
-- defined by IEEE 802.1a, i.e., as if it were transmitted least
-- significant bit first.
McMaster & McCloghrie [Page 11]
^L
RFC 1368 802.3 Repeater MIB October 1992
-- References
--
-- The following references are used throughout this MIB:
--
-- [IEEE 802.3 Std]
-- refers to IEEE 802.3/ISO 8802-3 Information processing
-- systems - Local area networks - Part 3: Carrier sense
-- multiple access with collision detection (CSMA/CD)
-- access method and physical layer specifications
-- (2nd edition, September 21, 1990).
--
-- [IEEE 802.3 Rptr Mgt]
-- refers to IEEE P802.3K, 'Layer Management for 10 Mb/s
-- Baseband Repeaters, Section 19,' Draft Supplement to
-- ANSI/IEEE 802.3, (Draft 8, April 9, 1992)
-- MIB Groups
--
-- The rptrBasicPackage group is mandatory.
-- The rptrMonitorPackage and rptrAddrTrackPackage
-- groups are optional.
rptrBasicPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 }
rptrMonitorPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 }
rptrAddrTrackPackage
OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 }
-- object identifiers for organizing the information
-- in the groups by repeater, port-group, and port
rptrRptrInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 1 }
rptrGroupInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 2 }
rptrPortInfo
OBJECT IDENTIFIER ::= { rptrBasicPackage 3 }
rptrMonitorRptrInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 }
rptrMonitorGroupInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 }
McMaster & McCloghrie [Page 12]
^L
RFC 1368 802.3 Repeater MIB October 1992
rptrMonitorPortInfo
OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 }
rptrAddrTrackRptrInfo -- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }
rptrAddrTrackGroupInfo -- this subtree is currently unused
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }
rptrAddrTrackPortInfo
OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }
--
-- The BASIC GROUP
--
-- Implementation of the Basic Group is mandatory for all
-- managed repeaters.
--
-- Basic Repeater Information
--
-- Configuration, status, and control objects for the overall
-- repeater
--
rptrGroupCapacity OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rptrGroupCapacity is the number of groups
that can be contained within the repeater. Within
each managed repeater, the groups are uniquely
numbered in the range from 1 to rptrGroupCapacity.
Some groups may not be present in the repeater, in
which case the actual number of groups present
will be less than rptrGroupCapacity. The number
of groups present will never be greater than
rptrGroupCapacity.
Note: In practice, this will generally be the
number of field-replaceable units (i.e., modules,
cards, or boards) that can fit in the physical
repeater enclosure, and the group numbers will
correspond to numbers marked on the physical
enclosure."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterGroupCapacity."
McMaster & McCloghrie [Page 13]
^L
RFC 1368 802.3 Repeater MIB October 1992
::= { rptrRptrInfo 1 }
rptrOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined or unknown status
ok(2), -- no known failures
rptrFailure(3), -- repeater-related failure
groupFailure(4), -- group-related failure
portFailure(5), -- port-related failure
generalFailure(6) -- failure, unspecified type
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rptrOperStatus object indicates the
operational state of the repeater. The
rptrHealthText object may be consulted for more
specific information about the state of the
repeater's health.
In the case of multiple kinds of failures (e.g.,
repeater failure and port failure), the value of
this attribute shall reflect the highest priority
failure in the following order:
rptrFailure(3)
groupFailure(4)
portFailure(5)
generalFailure(6)."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterHealthState."
::= { rptrRptrInfo 2 }
rptrHealthText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The health text object is a text string that
provides information relevant to the operational
state of the repeater. Agents may use this string
to provide detailed information on current
failures, including how they were detected, and/or
instructions for problem resolution. The contents
are agent-specific."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
McMaster & McCloghrie [Page 14]
^L
RFC 1368 802.3 Repeater MIB October 1992
aRepeaterHealthText."
::= { rptrRptrInfo 3 }
rptrReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to reset(2) causes a
transition to the START state of Fig 9-2 in
section 9 [IEEE 802.3 Std].
Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.
This action does not reset the management counters
defined in this document nor does it affect the
portAdminStatus parameters. Included in this
action is the execution of a disruptive Self-Test
with the following characteristics: a) The nature
of the tests is not specified. b) The test resets
the repeater but without affecting management
information about the repeater. c) The test does
not inject packets onto any segment. d) Packets
received during the test may or may not be
transferred. e) The test does not interfere with
management functions.
As a result of this action a rptrResetEvent trap
should be sent."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acResetRepeater."
::= { rptrRptrInfo 4 }
rptrNonDisruptTest OBJECT-TYPE
SYNTAX INTEGER {
noSelfTest(1),
selfTest(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to selfTest(2) causes the
McMaster & McCloghrie [Page 15]
^L
RFC 1368 802.3 Repeater MIB October 1992
repeater to perform a agent-specific, non-
disruptive self-test that has the following
characteristics: a) The nature of the tests is
not specified. b) The test does not change the
state of the repeater or management information
about the repeater. c) The test does not inject
packets onto any segment. d) The test does not
prevent the relay of any packets. e) The test
does not interfere with management functions.
After performing this test the agent will update
the repeater health information and send a
rptrHealth trap.
Setting this object to noSelfTest(1) has no
effect. The agent will always return the value
noSelfTest(1) when this object is read."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acExecuteNonDisruptiveSelfTest."
::= { rptrRptrInfo 5 }
rptrTotalPartitionedPorts OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the total number of ports in
the repeater whose current state meets all three
of the following criteria: rptrPortOperStatus
does not have the value notPresent(3),
rptrPortAdminStatus is enabled(1), and
rptrPortAutoPartitionState is autoPartitioned(2)."
::= { rptrRptrInfo 6 }
--
-- The Basic Port Group Table
--
rptrGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of descriptive and status information about
the groups of ports."
::= { rptrGroupInfo 1 }
McMaster & McCloghrie [Page 16]
^L
RFC 1368 802.3 Repeater MIB October 1992
rptrGroupEntry OBJECT-TYPE
SYNTAX RptrGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing information
about a single group of ports."
INDEX { rptrGroupIndex }
::= { rptrGroupTable 1 }
RptrGroupEntry ::=
SEQUENCE {
rptrGroupIndex
INTEGER,
rptrGroupDescr
DisplayString,
rptrGroupObjectID
OBJECT IDENTIFIER,
rptrGroupOperStatus
INTEGER,
rptrGroupLastOperStatusChange
TimeTicks,
rptrGroupPortCapacity
INTEGER
}
rptrGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group within the
repeater for which this entry contains
information. This value is never greater than
rptrGroupCapacity."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.5.2,
aGroupID."
::= { rptrGroupEntry 1 }
rptrGroupDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the group. This value
should include the full name and version
identification of the group's hardware type and
McMaster & McCloghrie [Page 17]
^L
RFC 1368 802.3 Repeater MIB October 1992
indicate how the group is differentiated from
other groups in the repeater. Plug-in Module, Rev
A' or 'Barney Rubble 10BASE-T 4-port SIMM socket
Version 2.1' are examples of valid group
descriptions.
It is mandatory that this only contain printable
ASCII characters."
::= { rptrGroupEntry 2 }
rptrGroupObjectID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The vendor's authoritative identification of the
group. This value is allocated within the SMI
enterprises subtree (1.3.6.1.4.1) and provides a
straight-forward and unambiguous means for
determining what kind of group is being managed.
For example, this object could take the value
1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
and had assigned the identifier
1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
6-Port FOIRL Plug-in Module.'"
::= { rptrGroupEntry 3 }
rptrGroupOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
operational(2),
malfunctioning(3),
notPresent(4),
underTest(5),
resetInProgress(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An object that indicates the operational status
of the group.
A status of notPresent(4) indicates that the group
is temporarily or permanently physically and/or
logically not a part of the repeater. It is an
implementation-specific matter as to whether the
McMaster & McCloghrie [Page 18]
^L
RFC 1368 802.3 Repeater MIB October 1992
agent effectively removes notPresent entries from
the table.
A status of operational(2) indicates that the
group is functioning, and a status of
malfunctioning(3) indicates that the group is
malfunctioning in some way."
::= { rptrGroupEntry 4 }
rptrGroupLastOperStatusChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An object that contains the value of sysUpTime at
the time that the value of the rptrGroupOperStatus
object for this group last changed.
A value of zero indicates that the group's oper
status has not changed since the agent last
restarted."
::= { rptrGroupEntry 5 }
rptrGroupPortCapacity OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rptrGroupPortCapacity is the number of ports
that can be contained within the group. Valid
range is 1-1024. Within each group, the ports are
uniquely numbered in the range from 1 to
rptrGroupPortCapacity.
Note: In practice, this will generally be the
number of ports on a module, card, or board, and
the port numbers will correspond to numbers marked
on the physical embodiment."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.5.2,
aGroupPortCapacity."
::= { rptrGroupEntry 6 }
McMaster & McCloghrie [Page 19]
^L
RFC 1368 802.3 Repeater MIB October 1992
--
-- The Basic Port Table
--
rptrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of descriptive and status information about
the ports."
::= { rptrPortInfo 1 }
rptrPortEntry OBJECT-TYPE
SYNTAX RptrPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing information
about a single port."
INDEX { rptrPortGroupIndex, rptrPortIndex }
::= { rptrPortTable 1 }
RptrPortEntry ::=
SEQUENCE {
rptrPortGroupIndex
INTEGER,
rptrPortIndex
INTEGER,
rptrPortAdminStatus
INTEGER,
rptrPortAutoPartitionState
INTEGER,
rptrPortOperStatus
INTEGER
}
rptrPortGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrPortEntry 1 }
rptrPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
McMaster & McCloghrie [Page 20]
^L
RFC 1368 802.3 Repeater MIB October 1992
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information. This
value can never be greater than
rptrGroupPortCapacity for the associated group."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aPortID."
::= { rptrPortEntry 2 }
rptrPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to disabled(2) disables the
port. A disabled port neither transmits nor
receives. Once disabled, a port must be
explicitly enabled to restore operation. A port
which is disabled when power is lost or when a
reset is exerted shall remain disabled when normal
operation resumes.
The admin status takes precedence over auto-
partition and functionally operates between the
auto-partition mechanism and the AUI/PMA.
Setting this object to enabled(1) enables the port
and exerts a BEGIN on the port's auto-partition
state machine.
(In effect, when a port is disabled, the value of
rptrPortAutoPartitionState for that port is frozen
until the port is next enabled. When the port
becomes enabled, the rptrPortAutoPartitionState
becomes notAutoPartitioned(1), regardless of its
pre-disabling state.)"
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aPortAdminState and 19.2.6.3, acPortAdminControl."
::= { rptrPortEntry 3 }
rptrPortAutoPartitionState OBJECT-TYPE
SYNTAX INTEGER {
McMaster & McCloghrie [Page 21]
^L
RFC 1368 802.3 Repeater MIB October 1992
notAutoPartitioned(1),
autoPartitioned(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The autoPartitionState flag indicates whether the
port is currently partitioned by the repeater's
auto-partition protection.
The conditions that cause port partitioning are
specified in partition state machine in Section 9
[IEEE 802.3 Std]. They are not differentiated
here."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aAutoPartitionState."
::= { rptrPortEntry 4 }
rptrPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
operational(1),
notOperational(2),
notPresent(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the port's operational
status. The notPresent(3) status indicates the
port is physically removed (note this may or may
not be possible depending on the type of port.)
The operational(1) status indicates that the port
is enabled (see rptrPortAdminStatus) and working,
even though it might be auto-partitioned (see
rptrPortAutoPartitionState).
If this object has the value operational(1) and
rptrPortAdminStatus is set to disabled(2), it is
expected that this object's value will change to
notOperational(2) soon after."
::= { rptrPortEntry 5 }
McMaster & McCloghrie [Page 22]
^L
RFC 1368 802.3 Repeater MIB October 1992
--
-- The MONITOR GROUP
--
-- Implementation of this group is optional, but within the
-- group all elements are mandatory. If a managed repeater
-- implements any part of this group, the entire group shall
-- be implemented.
--
-- Repeater Monitor Information
--
-- Performance monitoring statistics for the repeater
--
rptrMonitorTransmitCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented every time the
repeater state machine enters the TRANSMIT
COLLISION state from any state other than ONE PORT
LEFT (Ref: Fig 9-2, IEEE 802.3 Std).
The approximate minimum time for rollover of this
counter is 16 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aTransmitCollisions."
::= { rptrMonitorRptrInfo 1 }
--
-- The Group Monitor Table
--
rptrMonitorGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonitorGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of performance and error statistics for the
groups."
::= { rptrMonitorGroupInfo 1 }
rptrMonitorGroupEntry OBJECT-TYPE
SYNTAX RptrMonitorGroupEntry
McMaster & McCloghrie [Page 23]
^L
RFC 1368 802.3 Repeater MIB October 1992
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing total
performance and error statistics for a single
group. Regular retrieval of the information in
this table provides a means of tracking the
performance and health of the networked devices
attached to this group's ports.
The counters in this table are redundant in the
sense that they are the summations of information
already available through other objects. However,
these sums provide a considerable optimization of
network management traffic over the otherwise
necessary retrieval of the individual counters
included in each sum."
INDEX { rptrMonitorGroupIndex }
::= { rptrMonitorGroupTable 1 }
RptrMonitorGroupEntry ::=
SEQUENCE {
rptrMonitorGroupIndex
INTEGER,
rptrMonitorGroupTotalFrames
Counter,
rptrMonitorGroupTotalOctets
Counter,
rptrMonitorGroupTotalErrors
Counter
}
rptrMonitorGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group within the
repeater for which this entry contains
information."
::= { rptrMonitorGroupEntry 1 }
rptrMonitorGroupTotalFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of frames of valid frame length
McMaster & McCloghrie [Page 24]
^L
RFC 1368 802.3 Repeater MIB October 1992
that have been received on the ports in this
group. This counter is the summation of the
values of the rptrMonitorPortReadableFrames
counters for all of the ports in the group.
This statistic provides one of the parameters
necessary for obtaining the packet error rate.
The approximate minimum time for rollover of this
counter is 80 hours."
::= { rptrMonitorGroupEntry 2 }
rptrMonitorGroupTotalOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets contained in the valid
frames that have been received on the ports in
this group. This counter is the summation of the
values of the rptrMonitorPortReadableOctets
counters for all of the ports in the group.
This statistic provides an indicator of the total
data transferred. The approximate minimum time
for rollover of this counter is 58 minutes."
::= { rptrMonitorGroupEntry 3 }
rptrMonitorGroupTotalErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of errors which have occurred on
all of the ports in this group. This counter is
the summation of the values of the
rptrMonitorPortTotalErrors counters for all of the
ports in the group."
::= { rptrMonitorGroupEntry 4 }
--
-- The Port Monitor Table
--
rptrMonitorPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrMonitorPortEntry
ACCESS not-accessible
STATUS mandatory
McMaster & McCloghrie [Page 25]
^L
RFC 1368 802.3 Repeater MIB October 1992
DESCRIPTION
"Table of performance and error statistics for the
ports."
::= { rptrMonitorPortInfo 1 }
rptrMonitorPortEntry OBJECT-TYPE
SYNTAX RptrMonitorPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing performance and
error statistics for a single port."
INDEX { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
::= { rptrMonitorPortTable 1 }
RptrMonitorPortEntry ::=
SEQUENCE {
rptrMonitorPortGroupIndex
INTEGER,
rptrMonitorPortIndex
INTEGER,
rptrMonitorPortReadableFrames
Counter,
rptrMonitorPortReadableOctets
Counter,
rptrMonitorPortFCSErrors
Counter,
rptrMonitorPortAlignmentErrors
Counter,
rptrMonitorPortFrameTooLongs
Counter,
rptrMonitorPortShortEvents
Counter,
rptrMonitorPortRunts
Counter,
rptrMonitorPortCollisions
Counter,
rptrMonitorPortLateEvents
Counter,
rptrMonitorPortVeryLongEvents
Counter,
rptrMonitorPortDataRateMismatches
Counter,
rptrMonitorPortAutoPartitions
Counter,
rptrMonitorPortTotalErrors
Counter
}
McMaster & McCloghrie [Page 26]
^L
RFC 1368 802.3 Repeater MIB October 1992
rptrMonitorPortGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrMonitorPortEntry 1 }
rptrMonitorPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aPortID."
::= { rptrMonitorPortEntry 2 }
rptrMonitorPortReadableFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is the number of frames of valid
frame length that have been received on this port.
This counter is incremented by one for each frame
received on this port whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: IEEE 802.3 Std,
4.4.2.1) and for which the FCSError and
CollisionEvent signals are not asserted.
This statistic provides one of the parameters
necessary for obtaining the packet error rate.
The approximate minimum time for rollover of this
counter is 80 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aReadableFrames."
::= { rptrMonitorPortEntry 3 }
rptrMonitorPortReadableOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
McMaster & McCloghrie [Page 27]
^L
RFC 1368 802.3 Repeater MIB October 1992
DESCRIPTION
"This object is the number of octets contained in
valid frames that have been received on this port.
This counter is incremented by OctetCount for each
frame received on this port which has been
determined to be a readable frame.
This statistic provides an indicator of the total
data transferred. The approximate minimum time
for rollover of this counter is 58 minutes."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aReadableOctets."
::= { rptrMonitorPortEntry 4 }
rptrMonitorPortFCSErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each frame
received on this port with the FCSError signal
asserted and the FramingError and CollisionEvent
signals deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
Std).
The approximate minimum time for rollover of this
counter is 80 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aFrameCheckSequenceErrors."
::= { rptrMonitorPortEntry 5 }
rptrMonitorPortAlignmentErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each frame
received on this port with the FCSError and
FramingError signals asserted and CollisionEvent
signal deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: IEEE 802.3 Std,
4.4.2.1). If rptrMonitorPortAlignmentErrors is
incremented then the rptrMonitorPortFCSErrors
McMaster & McCloghrie [Page 28]
^L
RFC 1368 802.3 Repeater MIB October 1992
Counter shall not be incremented for the same
frame.
The approximate minimum time for rollover of this
counter is 80 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aAlignmentErrors."
::= { rptrMonitorPortEntry 6 }
rptrMonitorPortFrameTooLongs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each frame
received on this port whose OctetCount is greater
than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
If rptrMonitorPortFrameTooLongs is incremented
then neither the rptrMonitorPortAlignmentErrors
nor the rptrMonitorPortFCSErrors counter shall be
incremented for the frame.
The approximate minimum time for rollover of this
counter is 61 days."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aFramesTooLong."
::= { rptrMonitorPortEntry 7 }
rptrMonitorPortShortEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port with ActivityDuration
less than ShortEventMaxTime. ShortEventMaxTime is
greater than 74 bit times and less than 82 bit
times. ShortEventMaxTime has tolerances included
to provide for circuit losses between a
conformance test point at the AUI and the
measurement point within the state machine.
Note: shortEvents may indicate externally
generated noise hits which will cause the repeater
to transmit Runts to its other ports, or propagate
a collision (which may be late) back to the
McMaster & McCloghrie [Page 29]
^L
RFC 1368 802.3 Repeater MIB October 1992
transmitting DTE and damaged frames to the rest of
the network.
Implementors may wish to consider selecting the
ShortEventMaxTime towards the lower end of the
allowed tolerance range to accommodate bit losses
suffered through physical channel devices not
budgeted for within this standard.
The approximate minimum time for rollover of this
counter is 16 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aShortEvents."
::= { rptrMonitorPortEntry 8 }
rptrMonitorPortRunts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port that meets one of the
following two conditions. Only one test need be
made. a) The ActivityDuration is greater than
ShortEventMaxTime and less than ValidPacketMinTime
and the CollisionEvent signal is deasserted. b)
The OctetCount is less than 64, the
ActivityDuration is greater than ShortEventMaxTime
and the CollisionEvent signal is deasserted.
ValidPacketMinTime is greater than or equal to 552
bit times and less than 565 bit times.
An event whose length is greater than 74 bit times
but less than 82 bit times shall increment either
the shortEvents counter or the runts counter but
not both. A CarrierEvent greater than or equal to
552 bit times but less than 565 bit times may or
may not be counted as a runt.
ValidPacketMinTime has tolerances included to
provide for circuit losses between a conformance
test point at the AUI and the measurement point
within the state machine.
Runts usually indicate collision fragments, a
normal network event. In certain situations
associated with large diameter networks a
McMaster & McCloghrie [Page 30]
^L
RFC 1368 802.3 Repeater MIB October 1992
percentage of runts may exceed ValidPacketMinTime.
The approximate minimum time for rollover of this
counter is 16 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts."
::= { rptrMonitorPortEntry 9 }
rptrMonitorPortCollisions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for any
CarrierEvent signal on any port for which the
CollisionEvent signal on this port is asserted.
The approximate minimum time for rollover of this
counter is 16 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aCollisions."
::= { rptrMonitorPortEntry 10 }
rptrMonitorPortLateEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port in which the CollIn(X)
variable transitions to the value SQE (Ref:
9.6.6.2, IEEE 802.3 Std) while the
ActivityDuration is greater than the
LateEventThreshold. Such a CarrierEvent is
counted twice, as both a collision and as a
lateEvent.
The LateEventThreshold is greater than 480 bit
times and less than 565 bit times.
LateEventThreshold has tolerances included to
permit an implementation to build a single
threshold to serve as both the LateEventThreshold
and ValidPacketMinTime threshold.
The approximate minimum time for rollover of this
counter is 81 hours."
REFERENCE
McMaster & McCloghrie [Page 31]
^L
RFC 1368 802.3 Repeater MIB October 1992
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aLateEvents."
::= { rptrMonitorPortEntry 11 }
rptrMonitorPortVeryLongEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each
CarrierEvent on this port whose ActivityDuration
is greater than the MAU Jabber Lockup Protection
timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).
Other counters may be incremented as appropriate."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aVeryLongEvents."
::= { rptrMonitorPortEntry 12 }
rptrMonitorPortDataRateMismatches OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each frame
received on this port that meets all of the
following conditions: a) The CollisionEvent
signal is not asserted. b) The ActivityDuration
is greater than ValidPacketMinTime. c) The
frequency (data rate) is detectably mismatched
from the local transmit frequency. The exact
degree of mismatch is vendor specific and is to be
defined by the vendor for conformance testing.
When this event occurs, other counters whose
increment conditions were satisfied may or may not
also be incremented, at the implementor's
discretion. Whether or not the repeater was able
to maintain data integrity is beyond the scope of
this standard."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aDataRateMismatches."
::= { rptrMonitorPortEntry 13 }
rptrMonitorPortAutoPartitions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
McMaster & McCloghrie [Page 32]
^L
RFC 1368 802.3 Repeater MIB October 1992
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each time
the repeater has automatically partitioned this
port. The conditions that cause port partitioning
are specified in the partition state machine in
Section 9 [IEEE 802.3 Std]. They are not
differentiated here."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aAutoPartitions."
::= { rptrMonitorPortEntry 14 }
rptrMonitorPortTotalErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of errors which have occurred on
this port. This counter is the summation of the
values of other error counters (for the same
port), namely:
rptrMonitorPortFCSErrors,
rptrMonitorPortAlignmentErrors,
rptrMonitorPortFrameTooLongs,
rptrMonitorPortShortEvents,
rptrMonitorPortLateEvents,
rptrMonitorPortVeryLongEvents, and
rptrMonitorPortDataRateMismatches.
This counter is redundant in the sense that it is
the summation of information already available
through other objects. However, it is included
specifically because the regular retrieval of this
object as a means of tracking the health of a port
provides a considerable optimization of network
management traffic over the otherwise necessary
retrieval of the summed counters."
::= { rptrMonitorPortEntry 15 }
--
-- The ADDRESS TRACKING GROUP
--
-- Implementation of this group is optional; it is appropriate
-- for all systems which have the necessary metering. If a
-- managed repeater implements any part of this group, the entire
McMaster & McCloghrie [Page 33]
^L
RFC 1368 802.3 Repeater MIB October 1992
-- group shall be implemented.
--
-- The Port Address Tracking Table
--
rptrAddrTrackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RptrAddrTrackEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of address mapping information about the
ports."
::= { rptrAddrTrackPortInfo 1 }
rptrAddrTrackEntry OBJECT-TYPE
SYNTAX RptrAddrTrackEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the table, containing address mapping
information about a single port."
INDEX { rptrAddrTrackGroupIndex, rptrAddrTrackPortIndex }
::= { rptrAddrTrackTable 1 }
RptrAddrTrackEntry ::=
SEQUENCE {
rptrAddrTrackGroupIndex
INTEGER,
rptrAddrTrackPortIndex
INTEGER,
rptrAddrTrackLastSourceAddress
MacAddress,
rptrAddrTrackSourceAddrChanges
Counter
}
rptrAddrTrackGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the group containing the
port for which this entry contains information."
::= { rptrAddrTrackEntry 1 }
rptrAddrTrackPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
McMaster & McCloghrie [Page 34]
^L
RFC 1368 802.3 Repeater MIB October 1992
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aPortID."
::= { rptrAddrTrackEntry 2 }
rptrAddrTrackLastSourceAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is the SourceAddress of the last
readable frame (i.e., counted by
rptrMonitorPortReadableFrames) received by this
port."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aLastSourceAddress."
::= { rptrAddrTrackEntry 3 }
rptrAddrTrackSourceAddrChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter is incremented by one for each time
that the rptrAddrTrackLastSourceAddress attribute
for this port has changed.
This may indicate whether a link is connected to a
single DTE or another multi-user segment.
The approximate minimum time for rollover of this
counter is 81 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.6.2,
aSourceAddressChanges."
::= { rptrAddrTrackEntry 4 }
-- Traps for use by Repeaters
-- Traps are defined using the conventions in RFC 1215 [8].
rptrHealth TRAP-TYPE
McMaster & McCloghrie [Page 35]
^L
RFC 1368 802.3 Repeater MIB October 1992
ENTERPRISE snmpDot3RptrMgt
VARIABLES { rptrOperStatus }
DESCRIPTION
"The rptrHealth trap conveys information related
to the operational status of the repeater. This
trap is sent only when the oper status of the
repeater changes.
The rptrHealth trap must contain the
rptrOperStatus object. The agent may optionally
include the rptrHealthText object in the varBind
list. See the rptrOperStatus and rptrHealthText
objects for descriptions of the information that
is sent.
The agent must throttle the generation of
consecutive rptrHealth traps so that there is at
least a five-second gap between them."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.4,
hubHealth notification."
::= 1
rptrGroupChange TRAP-TYPE
ENTERPRISE snmpDot3RptrMgt
VARIABLES { rptrGroupIndex }
DESCRIPTION
"This trap is sent when a change occurs in the
group structure of a repeater. This occurs only
when a group is logically or physically removed
from or added to a repeater. The varBind list
contains the identifier of the group that was
removed or added.
The agent must throttle the generation of
consecutive rptrGroupChange traps for the same
group so that there is at least a five-second gap
between them."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.4,
groupMapChange notification."
::= 2
rptrResetEvent TRAP-TYPE
ENTERPRISE snmpDot3RptrMgt
VARIABLES { rptrOperStatus }
DESCRIPTION
"The rptrResetEvent trap conveys information
McMaster & McCloghrie [Page 36]
^L
RFC 1368 802.3 Repeater MIB October 1992
related to the operational status of the repeater.
This trap is sent on completion of a repeater
reset action. A repeater reset action is defined
as an a transition to the START state of Fig 9-2
in section 9 [IEEE 802.3 Std], when triggered by a
management command (e.g., an SNMP Set on the
rptrReset object).
The agent must throttle the generation of
consecutive rptrResetEvent traps so that there is
at least a five-second gap between them.
The rptrResetEvent trap is not sent when the agent
restarts and sends an SNMP coldStart or warmStart
trap. However, it is recommended that a repeater
agent send the rptrOperStatus object as an
optional object with its coldStart and warmStart
trap PDUs.
The rptrOperStatus object must be included in the
varbind list sent with this trap. The agent may
optionally include the rptrHealthText object as
well."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubReset
notification."
::= 3
END
5. Acknowledgments
This document is the work of the IETF Hub MIB Working Group. It is
based on drafts of the IEEE 802.3 Repeater Management Task Force.
Members of the working group included:
Karl Auerbach karl@eng.sun.com
Jim Barnes barnes@xylogics.com
Steve Bostock steveb@novell.com
David Bridgham dab@asylum.sf.ca.us
Jack Brown jbrown@huahuca-emh8.army.mil
Howard Brown brown@ctron.com
Lida Canin lida@apple.com
Jeffrey Case case@cs.utk.edu
Carson Cheung carson@bnr.com.ca
James Codespote jpcodes@tycho.ncsc.mil
John Cook cook@chipcom.com
Dave Cullerot cullerot@ctron.com
McMaster & McCloghrie [Page 37]
^L
RFC 1368 802.3 Repeater MIB October 1992
James Davin jrd@ptt.lcs.mit.edu
Gary Ellis garye@hpspd.spd.hp.com
David Engel david@cds.com
Mike Erlinger mike@mti.com
Jeff Erwin
Bill Fardy fardy@ctron.com
Jeff Fried jmf@relay.proteon.com
Bob Friesenhahn pdrusa!bob@uunet.uu.net
Shawn Gallagher gallagher@quiver.enet.dec.com
Mike Grieves mgrieves@chipcom.com
Walter Guilarte 70026.1715@compuserve.com
Phillip Hasse phasse@honchuca-emh8.army.mil
Mark Hoerth mark_hoerth@hp0400.desk.hp.com
Greg Hollingsworth gregh@mailer.jhuapl.edu
Ron Jacoby rj@sgi.com
Mike Janson mjanson@mot.com
Ken Jones konkord!ksj@uunet.uu.net
Satish Joshi sjoshi@synoptics.com
Frank Kastenholz kasten@europa.clearpoint.com
Manu Kaycee kaycee@trlian.enet.dec.com
Mark Kepke mak@cnd.hp.com
Mark Kerestes att!alux2!hawk@uunet.uu.net
Kenneth Key key@cs.utk.edu
Yoav Kluger ykluger@fibhaifa.com
Cheryl Krupczak cheryl@cc.gatech.edu
Ron Lau rlau@synoptics.com
Chao-Yu Liang cliang@synoptics.com
Dave Lindemulder da@mtung.att.com
Richie McBride rm@bix.co.uk
Keith McCloghrie kzm@hls.com
Evan McGinnis bem@3com.com
Donna McMaster mcmaster@synoptics.com
David Minnich dwm@fibercom.com
Lynn Monsanto monsanto@sun.com
Miriam Nihart miriam@decwet.zso.dec.com
Niels Ole Brunsgaard nob@dowtyns.dk
Edison Paw esp@3com.com
David Perkins dperkins@synoptics.com
Jason Perreault perreaul@interlan.interlan.com
John Pickens jrp@3com.com
Jim Reinstedler jimr@sceng.ub.com
Anil Rijsinghani anil@levers.enet.dec.com
Sam Roberts sroberts@farallon.com
Dan Romascanu dan@lannet.com
Marshall Rose mrose@dbc.mtview.ca.us
Rick Royston rick@lsumus.sncc.lsu.edu
Michael Sabo sabo@dockmaster.ncsc.mil
Jonathan Saperia saperia@tcpjon.enet.dec.com
McMaster & McCloghrie [Page 38]
^L
RFC 1368 802.3 Repeater MIB October 1992
Mark Schaefer schaefer@davidsys.com
Anil Singhal nsinghal@hawk.ulowell.edu
Timon Sloane peernet!timon@uunet.uu.net
Bob Stewart rlstewart@eng.xyplex.com
Emil Sturniolo emil@dss.com
Bruce Taber taber@interlan.com
Iris Tal 437-3580@mcimail.com
Mark Therieau markt@python.eng.microcom.com
Geoff Thompson thompson@synoptics.com
Dean Throop throop@dg-rtp.dg.com
Steven Waldbusser waldbusser@andrew.cmu.edu
Timothy Walden tmwalden@saturn.sys.acc.com
Philip Wang watadn!phil@uunet.uu.net
Drew Wansley dwansley@secola.columbia.ncr.com
David Ward dward@chipcom.com
Steve Wong wong@took.enet.dec.com
Paul Woodruff paul-woodruff@3com.com
Brian Wyld brianw@spider.co.uk
June-Kang Yang natadm!yang@uunet.uu.net
Henry Yip natadm!henry@uunet.uu.net
John Ziegler ziegler@artel.com
Joseph Zur fibronics!zur@uunet.uu.net
6. References
[1] Rose M., and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based internets", STD 16, RFC
1155, Performance Systems International, Hughes LAN Systems, May
1990.
[2] McCloghrie K., and M. Rose, "Management Information Base for
Network Management of TCP/IP-based internets", RFC 1156, Hughes
LAN Systems, Performance Systems International, May 1990.
[3] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
Network Management Protocol", STD 15, RFC 1157, SNMP Research,
Performance Systems International, Performance Systems
International, MIT Laboratory for Computer Science, May 1990.
[4] Rose M., Editor, "Management Information Base for Network
Management of TCP/IP-based internets: MIB-II", STD 17, RFC 1213,
Performance Systems International, March 1991.
[5] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1),
International Organization for Standardization, International
Standard 8824, December 1987.
McMaster & McCloghrie [Page 39]
^L
RFC 1368 802.3 Repeater MIB October 1992
[6] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One
(ASN.1), International Organization for Standardization,
International Standard 8825, December 1987.
[7] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
STD 16, RFC 1212, Performance Systems International, Hughes LAN
Systems, March 1991.
[8] Rose, M., Editor, "A Convention for Defining Traps for use with
the SNMP", RFC 1215, Performance Systems International, March
1991.
[9] IEEE 802.3/ISO 8802-3 Information processing systems - Local area
networks - Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications, 2nd edition, September 21, 1990.
[10] IEEE P802.3K, "Layer Management for 10 Mb/s Baseband Repeaters,
Section 19," Draft Supplement to ANSI/IEEE 802.3, Draft 8, April
9, 1992.
7. Security Considerations
Security issues are not discussed in this memo.
8. Authors' Addresses
Donna McMaster
SynOptics Communications, Inc.
4401 Great America Parkway
P.O. Box 58185
Santa Clara, CA 95052-8185
EMail: mcmaster@synoptics.com
Keith McCloghrie
Hughes LAN Systems, Inc.
1225 Charleston Road
Mountain View, CA 94043
Phone: (415) 966-7934
EMail: kzm@hls.com
McMaster & McCloghrie [Page 40]
^L
|