1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
|
Network Working Group J. Case
Request for Comments: 1512 The University of Tennesse and
Updates: 1285 SNMP Research, Incorporated
A. Rijsinghani
Digital Equipment Corporation
September 1993
FDDI Management Information Base
Status of this Memo
This RFC specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" for the standardization state and status
of this protocol. Distribution of this memo is unlimited.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP-based internets.
In particular, it defines objects for managing devices which
implement the FDDI based on the ANSI FDDI SMT 7.3 draft standard [8],
which has been forwarded for publication by the X3T9.5 committee.
Table of Contents
1. The Network Management Framework ...................... 2
1.1 Object Definitions ................................... 2
1.2 Format of Definitions ................................ 2
2. Overview .............................................. 2
2.1 Textual Conventions .................................. 3
3. Changes from RFC 1285 ................................. 3
4. Object Definitions .................................... 4
4.1 The SMT Group ........................................ 6
4.2 The MAC Group ........................................ 17
4.3 The Enhanced MAC Counters Group ...................... 29
4.4 The PATH Group ....................................... 32
4.5 The PORT Group ....................................... 38
5. Acknowledgements ...................................... 48
6. References ............................................ 50
7. Security Considerations ............................... 51
8. Authors' Addresses .................................... 51
Case & Rijsinghani [Page 1]
^L
RFC 1512 FDDI MIB September 1993
1. The Network Management Framework
The Internet-standard Network Management Framework consists of three
components. They are:
o STD 16, RFC 1155 which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of
management. STD 16, RFC 1212 defines a more concise description
mechanism, which is wholly consistent with the SMI.
o STD 17, RFC 1213 defines MIB-II, the core set of managed objects
for the Internet suite of protocols.
o STD 15, RFC 1157 which defines the SNMP, the protocol used for
network access to managed objects.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
1.1. Object Definitions
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1)
defined in the SMI. In particular, each object object type is named
by an OBJECT IDENTIFIER, an administratively assigned name. The
object type together with an object instance serves to uniquely
identify a specific instantiation of the object. For human
convenience, we often use a textual string, termed the descriptor, to
refer to the object type.
1.2. Format of Definitions
Section 4 contains contains the specification of all object types
contained in this MIB module. The object types are defined using the
conventions defined in the SMI, as amended by the extensions
specified in [7].
2. Overview
This document defines the managed objects for FDDI devices which are
to be accessible via the Simple Network Management Protocol (SNMP).
At present, this applies to these values of the ifType variable in
the Internet-standard MIB:
fddi(15)
For these interfaces, the value of the ifSpecific variable in the
Case & Rijsinghani [Page 2]
^L
RFC 1512 FDDI MIB September 1993
MIB-II [4] has the OBJECT IDENTIFIER value:
fddimib OBJECT IDENTIFIER ::= { fddi 73 }
The definitions of the objects presented here draws heavily from
related work in the ANSI X3T9.5 committee and the SMT subcommittee of
that committee [8]. In fact, the definitions of the managed objects
in this document are, to the maximum extent possible, identical to
those identified by the ANSI committee. The semantics of each
managed object should be the same with syntactic changes made as
necessary to recast the objects in terms of the Internet-standard SMI
and MIB so as to be compatible with the SNMP. Examples of these
syntactic changes include remapping booleans to enumerated integers,
remapping bit strings to octet strings, and the like. In addition,
the naming of the objects was changed to achieve compatibility.
These minimal syntactic changes with no semantic changes should allow
implementations of SNMP manageable FDDI systems to share
instrumentation with other network management schemes and thereby
minimize implementation cost. In addition, the translation of
information conveyed by managed objects from one network management
scheme to another is eased by these shared definitions.
Only the essential variables, as indicated by their mandatory status
in the ANSI specification, were retained in this document. The
importance of variables which have an optional status in the ANSI
specification were perceived as being less widely accepted.
2.1. Textual Conventions
Several new datatypes are introduced as a textual convention in this
MIB document. These textual conventions enhance the readability of
the document and ease comparisons with its ANSI counterpart. It
should be noted that the introduction of these textual conventions
has no effect on either the syntax or the semantics of any managed
objects. The use of these is merely an artifact of the explanatory
method used. Objects defined in terms of one of these methods are
always encoded by means of the rules that define the primitive type.
Hence, no changes to the SMI or the SNMP are necessary to accommodate
these textual conventions which are adopted merely for the
convenience of readers and writers in pursuit of the elusive goal of
clear, concise, and unambiguous MIB documents.
3. Changes from RFC 1285
The changes from RFC 1285 [2] to this document, based on changes from
ANSI SMT 6.2 to SMT 7.3, were so numerous that the objects in this
MIB module are located on a different branch of the MIB tree. No
Case & Rijsinghani [Page 3]
^L
RFC 1512 FDDI MIB September 1993
assumptions should be made about compatibility with RFC 1285.
4. Object Definitions
FDDI-SMT73-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
-- This MIB module uses the extended OBJECT-TYPE macro as
-- defined in [7].
-- this is the FDDI MIB module
fddi OBJECT IDENTIFIER ::= { transmission 15 }
fddimib OBJECT IDENTIFIER ::= { fddi 73 }
-- textual conventions
FddiTimeNano ::= INTEGER (0..2147483647)
-- This data type specifies 1 nanosecond units as
-- an integer value.
--
-- NOTE: The encoding is normal integer representation, not
-- two's complement. Since this type is used for variables
-- which are encoded as TimerTwosComplement in the ANSI
-- specification, two operations need to be performed on such
-- variables to convert from ANSI form to SNMP form:
--
-- 1) Convert from two's complement to normal integer
-- representation
-- 2) Multiply by 80 to convert from 80 nsec to 1 nsec units
--
-- No resolution is lost. Moreover, the objects for which
-- this data type is used effectively do not lose any range
-- due to the lower maximum value since they do not require
-- the full range.
--
-- Example: If fddimibMACTReq had a value of 8 ms, it would
-- be stored in ANSI TimerTwosComplement format as 0xFFFE7960
-- [8 ms is 100000 in 80 nsec units, which is then converted
-- to two's complement] but be reported as 8000000 in SNMP
-- since it is encoded here as FddiTimeNano.
Case & Rijsinghani [Page 4]
^L
RFC 1512 FDDI MIB September 1993
FddiTimeMilli ::= INTEGER (0..2147483647)
-- This data type is used for some FDDI timers. It specifies
-- time in 1 millisecond units, in normal integer
-- representation.
FddiResourceId ::= INTEGER (0..65535)
-- This data type is used to refer to an instance of a MAC,
-- PORT, or PATH Resource ID. Indexing begins
-- at 1. Zero is used to indicate the absence of a resource.
FddiSMTStationIdType ::= OCTET STRING (SIZE (8))
-- The unique identifier for the FDDI station. This is a
-- string of 8 octets, represented as X' yy yy xx xx xx xx
-- xx xx' with the low order 6 octet (xx) from a unique IEEE
-- assigned address. The high order two bits of the IEEE
-- address, the group address bit and the administration bit
-- (Universal/Local) bit should both be zero. The first two
-- octets, the yy octets, are implementor-defined.
--
-- The representation of the address portion of the station id
-- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for
-- 48 bit addresses. The canonical form is a 6-octet string
-- where the first octet contains the first 8 bits of the
-- address, with the I/G(Individual/Group) address bit as the
-- least significant bit and the U/L (Universal/Local) bit
-- as the next more significant bit, and so on. Note that
-- addresses in the ANSI FDDI standard SMT frames are
-- represented in FDDI MAC order.
FddiMACLongAddressType ::= OCTET STRING (SIZE (6))
-- The representation of long MAC addresses as management
-- values is in the IEEE (ANSI/IEEE P802.1A) canonical
-- notation for 48 bit addresses. The canonical form is a
-- 6-octet string where the first octet contains the first 8
-- bits of the address, with the I/G (Individual/Group)
-- address bit as the least significant bit and the U/L
-- (Universal/Local) bit as the next more significant bit,
-- and so on. Note that the addresses in the SMT frames are
-- represented in FDDI MAC order.
-- groups in the FDDI MIB module
fddimibSMT OBJECT IDENTIFIER ::= { fddimib 1 }
fddimibMAC OBJECT IDENTIFIER ::= { fddimib 2 }
fddimibMACCounters OBJECT IDENTIFIER ::= { fddimib 3 }
Case & Rijsinghani [Page 5]
^L
RFC 1512 FDDI MIB September 1993
fddimibPATH OBJECT IDENTIFIER ::= { fddimib 4 }
fddimibPORT OBJECT IDENTIFIER ::= { fddimib 5 }
-- the SMT group
-- Implementation of the SMT group is mandatory for all
-- systems which implement manageable FDDI subsystems.
fddimibSMTNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SMT implementations (regardless of
their current state) on this network management
application entity. The value for this variable
must remain constant at least from one re-
initialization of the entity's network management
system to the next re-initialization."
::= { fddimibSMT 1 }
-- the SMT table
fddimibSMTTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibSMTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of SMT entries. The number of entries
shall not exceed the value of fddimibSMTNumber."
::= { fddimibSMT 2 }
fddimibSMTEntry OBJECT-TYPE
SYNTAX FddimibSMTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An SMT entry containing information common to a
given SMT."
INDEX { fddimibSMTIndex }
::= { fddimibSMTTable 1 }
FddimibSMTEntry ::=
SEQUENCE {
fddimibSMTIndex
INTEGER,
Case & Rijsinghani [Page 6]
^L
RFC 1512 FDDI MIB September 1993
fddimibSMTStationId
FddiSMTStationIdType,
fddimibSMTOpVersionId
INTEGER,
fddimibSMTHiVersionId
INTEGER,
fddimibSMTLoVersionId
INTEGER,
fddimibSMTUserData
OCTET STRING,
fddimibSMTMIBVersionId
INTEGER,
fddimibSMTMACCts
INTEGER,
fddimibSMTNonMasterCts
INTEGER,
fddimibSMTMasterCts
INTEGER,
fddimibSMTAvailablePaths
INTEGER,
fddimibSMTConfigCapabilities
INTEGER,
fddimibSMTConfigPolicy
INTEGER,
fddimibSMTConnectionPolicy
INTEGER,
fddimibSMTTNotify
INTEGER,
fddimibSMTStatRptPolicy
INTEGER,
fddimibSMTTraceMaxExpiration
FddiTimeMilli,
fddimibSMTBypassPresent
INTEGER,
fddimibSMTECMState
INTEGER,
fddimibSMTCFState
INTEGER,
fddimibSMTRemoteDisconnectFlag
INTEGER,
fddimibSMTStationStatus
INTEGER,
fddimibSMTPeerWrapFlag
INTEGER,
fddimibSMTTimeStamp
FddiTimeMilli,
fddimibSMTTransitionTimeStamp
FddiTimeMilli,
Case & Rijsinghani [Page 7]
^L
RFC 1512 FDDI MIB September 1993
fddimibSMTStationAction
INTEGER
}
fddimibSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. The value for each
SMT must remain constant at least from one re-
initialization of the entity's network management
system to the next re-initialization."
::= { fddimibSMTEntry 1 }
fddimibSMTStationId OBJECT-TYPE
SYNTAX FddiSMTStationIdType -- OCTET STRING (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Used to uniquely identify an FDDI station."
REFERENCE
"ANSI { fddiSMT 11 }"
::= { fddimibSMTEntry 2 }
fddimibSMTOpVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version that this station is using for its
operation (refer to ANSI 7.1.2.2). The value of
this variable is 2 for this SMT revision."
REFERENCE
"ANSI { fddiSMT 13 }"
::= { fddimibSMTEntry 3 }
fddimibSMTHiVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest version of SMT that this station
supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 14 }"
::= { fddimibSMTEntry 4 }
Case & Rijsinghani [Page 8]
^L
RFC 1512 FDDI MIB September 1993
fddimibSMTLoVersionId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The lowest version of SMT that this station
supports (refer to ANSI 7.1.2.2)."
REFERENCE
"ANSI { fddiSMT 15 }"
::= { fddimibSMTEntry 5 }
fddimibSMTUserData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable contains 32 octets of user defined
information. The information shall be an ASCII
string."
REFERENCE
"ANSI { fddiSMT 17 }"
::= { fddimibSMTEntry 6 }
fddimibSMTMIBVersionId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the FDDI MIB of this station. The
value of this variable is 1 for this SMT
revision."
REFERENCE
"ANSI { fddiSMT 18 }"
::= { fddimibSMTEntry 7 }
fddimibSMTMACCts OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of MACs in this station or
concentrator."
REFERENCE
"ANSI { fddiSMT 21 }"
::= { fddimibSMTEntry 8 }
fddimibSMTNonMasterCts OBJECT-TYPE
SYNTAX INTEGER (0..2)
Case & Rijsinghani [Page 9]
^L
RFC 1512 FDDI MIB September 1993
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this variable is the number of A, B,
and S ports in this station or concentrator."
REFERENCE
"ANSI { fddiSMT 22 }"
::= { fddimibSMTEntry 9 }
fddimibSMTMasterCts OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of M Ports in a node. If the node is
not a concentrator, the value of the variable is
zero."
REFERENCE
"ANSI { fddiSMT 23 }"
::= { fddimibSMTEntry 10 }
fddimibSMTAvailablePaths OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that indicates the PATH types available
in the station.
The value is a sum. This value initially takes
the value zero, then for each type of PATH that
this node has available, 2 raised to a power is
added to the sum. The powers are according to the
following table:
Path Power
Primary 0
Secondary 1
Local 2
For example, a station having Primary and Local
PATHs available would have a value of 5 (2**0 +
2**2)."
REFERENCE
"ANSI { fddiSMT 24 }"
::= { fddimibSMTEntry 11 }
fddimibSMTConfigCapabilities OBJECT-TYPE
Case & Rijsinghani [Page 10]
^L
RFC 1512 FDDI MIB September 1993
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that indicates the configuration
capabilities of a node. The 'Hold Available' bit
indicates the support of the optional Hold
Function, which is controlled by
fddiSMTConfigPolicy. The 'CF-Wrap-AB' bit
indicates that the station has the capability of
performing a wrap_ab (refer to ANSI SMT 9.7.2.2).
The value is a sum. This value initially takes
the value zero, then for each of the configuration
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
holdAvailable 0
CF-Wrap-AB 1 "
REFERENCE
"ANSI { fddiSMT 25 }"
::= { fddimibSMTEntry 12 }
fddimibSMTConfigPolicy OBJECT-TYPE
SYNTAX INTEGER (0..1)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value that indicates the configuration policies
currently desired in a node. 'Hold' is one of the
terms used for the Hold Flag, an optional ECM flag
used to enable the optional Hold policy.
The value is a sum. This value initially takes
the value zero, then for each of the configuration
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
configurationhold 0 "
REFERENCE
"ANSI { fddiSMT 26 }"
::= { fddimibSMTEntry 13 }
fddimibSMTConnectionPolicy OBJECT-TYPE
Case & Rijsinghani [Page 11]
^L
RFC 1512 FDDI MIB September 1993
SYNTAX INTEGER (32768..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value representing the connection policies in
effect in a node. A station sets the corresponding
bit for each of the connection types that it
rejects. The letter designations, X and Y, in the
'rejectX-Y' names have the following significance:
X represents the PC-Type of the local PORT and Y
represents the PC_Type of the adjacent PORT
(PC_Neighbor). The evaluation of Connection-
Policy (PC-Type, PC-Neighbor) is done to determine
the setting of T- Val(3) in the PC-Signalling
sequence (refer to ANSI 9.6.3). Note that Bit 15,
(rejectM-M), is always set and cannot be cleared.
The value is a sum. This value initially takes
the value zero, then for each of the connection
policies currently enforced on the node, 2 raised
to a power is added to the sum. The powers are
according to the following table:
Policy Power
rejectA-A 0
rejectA-B 1
rejectA-S 2
rejectA-M 3
rejectB-A 4
rejectB-B 5
rejectB-S 6
rejectB-M 7
rejectS-A 8
rejectS-B 9
rejectS-S 10
rejectS-M 11
rejectM-A 12
rejectM-B 13
rejectM-S 14
rejectM-M 15 "
REFERENCE
"ANSI { fddiSMT 27 }"
::= { fddimibSMTEntry 14 }
fddimibSMTTNotify OBJECT-TYPE
SYNTAX INTEGER (2..30)
ACCESS read-write
STATUS mandatory
Case & Rijsinghani [Page 12]
^L
RFC 1512 FDDI MIB September 1993
DESCRIPTION
"The timer, expressed in seconds, used in the
Neighbor Notification protocol. It has a range of
2 seconds to 30 seconds, and its default value is
30 seconds (refer to ANSI SMT 8.2)."
REFERENCE
"ANSI { fddiSMT 29 }"
::= { fddimibSMTEntry 15 }
fddimibSMTStatRptPolicy OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If true, indicates that the node will generate
Status Reporting Frames for its implemented events
and conditions. It has an initial value of true.
This variable determines the value of the
SR_Enable Flag (refer to ANSI SMT 8.3.2.1)."
REFERENCE
"ANSI { fddiSMT 30 }"
::= { fddimibSMTEntry 16 }
fddimibSMTTraceMaxExpiration OBJECT-TYPE
SYNTAX FddiTimeMilli
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reference Trace_Max (refer to ANSI SMT
9.4.4.2.2)."
REFERENCE
"ANSI { fddiSMT 31 }"
::= { fddimibSMTEntry 17 }
fddimibSMTBypassPresent OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A flag indicating if the station has a bypass on
its AB port pair."
REFERENCE
"ANSI { fddiSMT 34 }"
::= { fddimibSMTEntry 18 }
fddimibSMTECMState OBJECT-TYPE
SYNTAX INTEGER {
ec0(1), -- Out
Case & Rijsinghani [Page 13]
^L
RFC 1512 FDDI MIB September 1993
ec1(2), -- In
ec2(3), -- Trace
ec3(4), -- Leave
ec4(5), -- Path_Test
ec5(6), -- Insert
ec6(7), -- Check
ec7(8) -- Deinsert
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current state of the ECM state
machine (refer to ANSI SMT 9.5.2)."
REFERENCE
"ANSI { fddiSMT 41 }"
::= { fddimibSMTEntry 19 }
fddimibSMTCFState OBJECT-TYPE
SYNTAX INTEGER {
cf0(1), -- isolated
cf1(2), -- local_a
cf2(3), -- local_b
cf3(4), -- local_ab
cf4(5), -- local_s
cf5(6), -- wrap_a
cf6(7), -- wrap_b
cf7(8), -- wrap_ab
cf8(9), -- wrap_s
cf9(10), -- c_wrap_a
cf10(11), -- c_wrap_b
cf11(12), -- c_wrap_s
cf12(13) -- thru
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The attachment configuration for the station or
concentrator (refer to ANSI SMT 9.7.2.2)."
REFERENCE
"ANSI { fddiSMT 42 }"
::= { fddimibSMTEntry 20 }
fddimibSMTRemoteDisconnectFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A flag indicating that the station was remotely
Case & Rijsinghani [Page 14]
^L
RFC 1512 FDDI MIB September 1993
disconnected from the network as a result of
receiving an fddiSMTAction, disconnect (refer to
ANSI SMT 6.4.5.3) in a Parameter Management Frame.
A station requires a Connect Action to rejoin and
clear the flag (refer to ANSI SMT 6.4.5.2)."
REFERENCE
"ANSI { fddiSMT 44 }"
::= { fddimibSMTEntry 21 }
fddimibSMTStationStatus OBJECT-TYPE
SYNTAX INTEGER { concatenated(1), separated(2), thru(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of the primary and secondary
paths within this station."
REFERENCE
"ANSI { fddiSMT 45 }"
::= { fddimibSMTEntry 22 }
fddimibSMTPeerWrapFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable assumes the value of the
PeerWrapFlag in CFM (refer to ANSI SMT
9.7.2.4.4)."
REFERENCE
"ANSI { fddiSMT 46 }"
::= { fddimibSMTEntry 23 }
fddimibSMTTimeStamp OBJECT-TYPE
SYNTAX FddiTimeMilli
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable assumes the value of TimeStamp
(refer to ANSI SMT 8.3.2.1)."
REFERENCE
"ANSI { fddiSMT 51 }"
::= { fddimibSMTEntry 24 }
fddimibSMTTransitionTimeStamp OBJECT-TYPE
SYNTAX FddiTimeMilli
ACCESS read-only
STATUS mandatory
DESCRIPTION
Case & Rijsinghani [Page 15]
^L
RFC 1512 FDDI MIB September 1993
"This variable assumes the value of
TransitionTimeStamp (refer to ANSI SMT 8.3.2.1)."
REFERENCE
"ANSI { fddiSMT 52 }"
::= { fddimibSMTEntry 25 }
fddimibSMTStationAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
connect(2),
disconnect(3),
path-Test(4),
self-Test(5),
disable-a(6),
disable-b(7),
disable-m(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object, when read, always returns a value of
other(1). The behavior of setting this variable
to each of the acceptable values is as follows:
other(1): Results in an appropriate error.
connect(2): Generates a Connect signal to ECM
to begin a connection sequence. See ANSI
Ref 9.4.2.
disconnect(3): Generates a Disconnect signal
to ECM. see ANSI Ref 9.4.2.
path-Test(4): Initiates a station Path_Test.
The Path_Test variable (see ANSI Ref
9.4.1) is set to 'Testing'. The results
of this action are not specified in this
standard.
self-Test(5): Initiates a station Self_Test.
The results of this action are not
specified in this standard.
disable-a(6): Causes a PC_Disable on the A
port if the A port mode is peer.
disable-b(7): Causes a PC_Disable on the B
port if the B port mode is peer.
disable-m(8): Causes a PC_Disable on all M
ports.
Attempts to set this object to all other values
results in an appropriate error. The result of
setting this variable to path-Test(4) or self-
Case & Rijsinghani [Page 16]
^L
RFC 1512 FDDI MIB September 1993
Test(5) is implementation-specific."
REFERENCE
"ANSI { fddiSMT 60 }"
::= { fddimibSMTEntry 26 }
-- the MAC group
-- Implementation of the MAC Group is mandatory for all
-- systems which implement manageable FDDI subsystems.
fddimibMACNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of MAC implementations (across
all SMTs) on this network management application
entity. The value for this variable must remain
constant at least from one re-initialization of
the entity's network management system to the next
re-initialization."
::= { fddimibMAC 1 }
-- the MAC table
fddimibMACTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibMACEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MAC entries. The number of entries
shall not exceed the value of fddimibMACNumber."
::= { fddimibMAC 2 }
fddimibMACEntry OBJECT-TYPE
SYNTAX FddimibMACEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A MAC entry containing information common to a
given MAC."
INDEX { fddimibMACSMTIndex, fddimibMACIndex }
::= { fddimibMACTable 1 }
FddimibMACEntry ::=
SEQUENCE {
fddimibMACSMTIndex
Case & Rijsinghani [Page 17]
^L
RFC 1512 FDDI MIB September 1993
INTEGER,
fddimibMACIndex
INTEGER,
fddimibMACIfIndex
INTEGER,
fddimibMACFrameStatusFunctions
INTEGER,
fddimibMACTMaxCapability
FddiTimeNano,
fddimibMACTVXCapability
FddiTimeNano,
fddimibMACAvailablePaths
INTEGER,
fddimibMACCurrentPath
INTEGER,
fddimibMACUpstreamNbr
FddiMACLongAddressType,
fddimibMACDownstreamNbr
FddiMACLongAddressType,
fddimibMACOldUpstreamNbr
FddiMACLongAddressType,
fddimibMACOldDownstreamNbr
FddiMACLongAddressType,
fddimibMACDupAddressTest
INTEGER,
fddimibMACRequestedPaths
INTEGER,
fddimibMACDownstreamPORTType
INTEGER,
fddimibMACSMTAddress
FddiMACLongAddressType,
fddimibMACTReq
FddiTimeNano,
fddimibMACTNeg
FddiTimeNano,
fddimibMACTMax
FddiTimeNano,
fddimibMACTvxValue
FddiTimeNano,
fddimibMACFrameCts
Counter,
fddimibMACCopiedCts
Counter,
fddimibMACTransmitCts
Counter,
fddimibMACErrorCts
Counter,
fddimibMACLostCts
Case & Rijsinghani [Page 18]
^L
RFC 1512 FDDI MIB September 1993
Counter,
fddimibMACFrameErrorThreshold
INTEGER,
fddimibMACFrameErrorRatio
INTEGER,
fddimibMACRMTState
INTEGER,
fddimibMACDaFlag
INTEGER,
fddimibMACUnaDaFlag
INTEGER,
fddimibMACFrameErrorFlag
INTEGER,
fddimibMACMAUnitdataAvailable
INTEGER,
fddimibMACHardwarePresent
INTEGER,
fddimibMACMAUnitdataEnable
INTEGER
}
fddimibMACSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the SMT index associated with this
MAC."
::= { fddimibMACEntry 1 }
fddimibMACIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the MAC
object instances, which is the same as the
corresponding resource index in SMT."
REFERENCE
"ANSI { fddiMAC 34 }"
::= { fddimibMACEntry 2 }
fddimibMACIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
Case & Rijsinghani [Page 19]
^L
RFC 1512 FDDI MIB September 1993
"The value of the MIB-II ifIndex corresponding to
this MAC. If none is applicable, 0 is returned."
REFERENCE
"MIB-II"
::= { fddimibMACEntry 3 }
fddimibMACFrameStatusFunctions OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the MAC's optional Frame Status
processing functions.
The value is a sum. This value initially takes
the value zero, then for each function present, 2
raised to a power is added to the sum. The powers
are according to the following table:
function Power
fs-repeating 0
fs-setting 1
fs-clearing 2 "
REFERENCE
"ANSI { fddiMAC 11 }"
::= { fddimibMACEntry 4 }
fddimibMACTMaxCapability OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum time value of fddiMACTMax
that this MAC can support."
REFERENCE
"ANSI { fddiMAC 13 }"
::= { fddimibMACEntry 5 }
fddimibMACTVXCapability OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the maximum time value of
fddiMACTvxValue that this MAC can support."
REFERENCE
"ANSI { fddiMAC 14 }"
::= { fddimibMACEntry 6 }
Case & Rijsinghani [Page 20]
^L
RFC 1512 FDDI MIB September 1993
fddimibMACAvailablePaths OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the paths available for this MAC (refer
to ANSI SMT 9.7.7).
The value is a sum. This value initially takes
the value zero, then for each type of PATH that
this MAC has available, 2 raised to a power is
added to the sum. The powers are according to the
following table:
Path Power
Primary 0
Secondary 1
Local 2 "
REFERENCE
"ANSI { fddiMAC 22 }"
::= { fddimibMACEntry 7 }
fddimibMACCurrentPath OBJECT-TYPE
SYNTAX INTEGER {
isolated(1),
local(2),
secondary(3),
primary(4),
concatenated(5),
thru(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the Path into which this MAC is
currently inserted (refer to ANSI 9.7.7)."
REFERENCE
"ANSI { fddiMAC 23 }"
::= { fddimibMACEntry 8 }
fddimibMACUpstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC's upstream neighbor's long individual MAC
address. It has an initial value of the SMT-
Unknown-MAC Address and is only modified as
Case & Rijsinghani [Page 21]
^L
RFC 1512 FDDI MIB September 1993
specified by the Neighbor Information Frame
protocol (refer to ANSI SMT 7.2.1 and 8.2)."
REFERENCE
"ANSI { fddiMAC 24 }"
::= { fddimibMACEntry 9 }
fddimibMACDownstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC's downstream neighbor's long individual
MAC address. It has an initial value of the SMT-
Unknown-MAC Address and is only modified as
specified by the Neighbor Information Frame
protocol (refer to ANSI SMT 7.2.1 and 8.2)."
REFERENCE
"ANSI { fddiMAC 25 }"
::= { fddimibMACEntry 10 }
fddimibMACOldUpstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The previous value of the MAC's upstream
neighbor's long individual MAC address. It has an
initial value of the SMT-Unknown- MAC Address and
is only modified as specified by the Neighbor
Information Frame protocol (refer to ANSI SMT
7.2.1 and 8.2)."
REFERENCE
"ANSI { fddiMAC 26 }"
::= { fddimibMACEntry 11 }
fddimibMACOldDownstreamNbr OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The previous value of the MAC's downstream
neighbor's long individual MAC address. It has an
initial value of the SMT- Unknown-MAC Address and
is only modified as specified by the Neighbor
Information Frame protocol (refer to ANSI SMT
7.2.1 and 8.2)."
REFERENCE
"ANSI { fddiMAC 27 }"
Case & Rijsinghani [Page 22]
^L
RFC 1512 FDDI MIB September 1993
::= { fddimibMACEntry 12 }
fddimibMACDupAddressTest OBJECT-TYPE
SYNTAX INTEGER { none(1), pass(2), fail(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Duplicate Address Test flag, Dup_Addr_Test
(refer to ANSI 8.2)."
REFERENCE
"ANSI { fddiMAC 29 }"
::= { fddimibMACEntry 13 }
fddimibMACRequestedPaths OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"List of permitted Paths which specifies the
Path(s) into which the MAC may be inserted (refer
to ansi SMT 9.7).
The value is a sum which represents the individual
paths that are desired. This value initially
takes the value zero, then for each type of PATH
that this node is, 2 raised to a power is added to
the sum. The powers are according to the
following table:
Path Power
local 0
secondary-alternate 1
primary-alternate 2
concatenated-alternate 3
secondary-preferred 4
primary-preferred 5
concatenated-preferred 6
thru 7 "
REFERENCE
"ANSI { fddiMAC 32 }"
::= { fddimibMACEntry 14 }
fddimibMACDownstreamPORTType OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the PC-Type of the first port that is
Case & Rijsinghani [Page 23]
^L
RFC 1512 FDDI MIB September 1993
downstream of this MAC (the exit port)."
REFERENCE
"ANSI { fddiMAC 33 }"
::= { fddimibMACEntry 15 }
fddimibMACSMTAddress OBJECT-TYPE
SYNTAX FddiMACLongAddressType -- OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 48-bit individual address of the MAC used for
SMT frames."
REFERENCE
"ANSI { fddiMAC 41 }"
::= { fddimibMACEntry 16 }
fddimibMACTReq OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is the T_Req_value passed to the
MAC. Without having detected a duplicate, the
time value of this variable shall assume the
maximum supported time value which is less than or
equal to the time value of fddiPATHMaxT-Req. When
a MAC has an address detected as a duplicate, it
may use a time value for this variable greater
than the time value of fddiPATHTMaxLowerBound. A
station shall cause claim when the new T_Req may
cause the value of T_Neg to change in the claim
process, (i.e., time value new T_Req < T_Neg, or
old T_Req = T_Neg)."
REFERENCE
"ANSI { fddiMAC 51 }"
::= { fddimibMACEntry 17 }
fddimibMACTNeg OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is reported as a FddiTimeNano number."
REFERENCE
"ANSI { fddiMAC 52 }"
::= { fddimibMACEntry 18 }
fddimibMACTMax OBJECT-TYPE
Case & Rijsinghani [Page 24]
^L
RFC 1512 FDDI MIB September 1993
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is the T_Max_value passed to the
MAC. The time value of this variable shall assume
the minimum suported time value which is greater
than or equal to the time value of fddiPATHT-
MaxLowerBound"
REFERENCE
"ANSI { fddiMAC 53 }"
::= { fddimibMACEntry 19 }
fddimibMACTvxValue OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is the TVX_value passed to the MAC.
The time value of this variable shall assume the
minimum suported time value which is greater than
or equal to the time value of
fddiPATHTVXLowerBound."
REFERENCE
"ANSI { fddiMAC 54 }"
::= { fddimibMACEntry 20 }
fddimibMACFrameCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of frames received by this
MAC (refer to ANSI MAC 7.5.1)."
REFERENCE
"ANSI { fddiMAC 71 }"
::= { fddimibMACEntry 21 }
fddimibMACCopiedCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of frames addressed to (A bit set) and
successfully copied into the station's receive
buffers (C bit set) by this MAC (refer to ANSI MAC
7.5). Note that this count does not include MAC
Case & Rijsinghani [Page 25]
^L
RFC 1512 FDDI MIB September 1993
frames."
REFERENCE
"ANSI { fddiMAC 72 }"
::= { fddimibMACEntry 22 }
fddimibMACTransmitCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of frames transmitted by this MAC
(refer to ANSI MAC 7.5). Note that this count
does not include MAC frames."
REFERENCE
"ANSI { fddiMAC 73 }"
::= { fddimibMACEntry 23 }
fddimibMACErrorCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of frames that were
detected in error by this MAC that had not been
detected in error by another MAC (refer to ANSI
MAC 7.5.2)."
REFERENCE
"ANSI { fddiMAC 81 }"
::= { fddimibMACEntry 24 }
fddimibMACLostCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of the number of instances that this MAC
detected a format error during frame reception
such that the frame was stripped (refer to ANSI
MAC 7.5.3)."
REFERENCE
"ANSI { fddiMAC 82 }"
::= { fddimibMACEntry 25 }
fddimibMACFrameErrorThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
Case & Rijsinghani [Page 26]
^L
RFC 1512 FDDI MIB September 1993
DESCRIPTION
"A threshold for determining when a MAC Condition
report (see ANSI 8.3.1.1) shall be generated.
Stations not supporting variable thresholds shall
have a value of 0 and a range of (0..0)."
REFERENCE
"ANSI { fddiMAC 95 }"
::= { fddimibMACEntry 26 }
fddimibMACFrameErrorRatio OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is the value of the ratio,
((delta fddiMACLostCts + delta fddiMACErrorCts) /
(delta fddiMACFrameCts + delta fddiMACLostCts ))
* 2**16 "
REFERENCE
"ANSI { fddiMAC 96 }"
::= { fddimibMACEntry 27 }
fddimibMACRMTState OBJECT-TYPE
SYNTAX INTEGER {
rm0(1), -- Isolated
rm1(2), -- Non_Op
rm2(3), -- Ring_Op
rm3(4), -- Detect
rm4(5), -- Non_Op_Dup
rm5(6), -- Ring_Op_Dup
rm6(7), -- Directed
rm7(8) -- Trace
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current state of the RMT State
Machine (refer to ANSI 10.3.2)."
REFERENCE
"ANSI { fddiMAC 111 }"
::= { fddimibMACEntry 28 }
fddimibMACDaFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
Case & Rijsinghani [Page 27]
^L
RFC 1512 FDDI MIB September 1993
"The RMT flag Duplicate Address Flag, DA_Flag
(refer to ANSI 10.2.1.2)."
REFERENCE
"ANSI { fddiMAC 112 }"
::= { fddimibMACEntry 29 }
fddimibMACUnaDaFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A flag, UNDA_Flag (refer to ANSI 8.2.2.1), set
when the upstream neighbor reports a duplicate
address condition. Cleared when the condition
clears."
REFERENCE
"ANSI { fddiMAC 113 }"
::= { fddimibMACEntry 30 }
fddimibMACFrameErrorFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the MAC Frame Error Condition is
present when set. Cleared when the condition
clears and on station initialization."
REFERENCE
"ANSI { fddiMAC 114 }"
::= { fddimibMACEntry 31 }
fddimibMACMAUnitdataAvailable OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shall take on the value of the
MAC_Avail flag defined in RMT."
REFERENCE
"ANSI { fddiMAC 116 }"
::= { fddimibMACEntry 32 }
fddimibMACHardwarePresent OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the presence of
Case & Rijsinghani [Page 28]
^L
RFC 1512 FDDI MIB September 1993
underlying hardware support for this MAC object.
If the value of this object is false(2), the
reporting of the objects in this entry may be
handled in an implementation-specific manner."
REFERENCE
"ANSI { fddiMAC 117 }"
::= { fddimibMACEntry 33 }
fddimibMACMAUnitdataEnable OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable determines the value of the
MA_UNITDATA_Enable flag in RMT. The default and
initial value of this flag is true(1)."
REFERENCE
"ANSI { fddiMAC 118 }"
::= { fddimibMACEntry 34 }
-- the Enhanced MAC Counters group
-- Implementation of this Group is optional, but systems
-- claiming support must implement all variables in this
-- group
-- the MAC Counters table
fddimibMACCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibMACCountersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MAC Counters entries. The number of
entries shall not exceed the value of
fddimibMACNumber."
::= { fddimibMACCounters 1 }
fddimibMACCountersEntry OBJECT-TYPE
SYNTAX FddimibMACCountersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A MAC Counters entry containing information
common to a given MAC."
INDEX { fddimibMACSMTIndex, fddimibMACIndex }
::= { fddimibMACCountersTable 1 }
Case & Rijsinghani [Page 29]
^L
RFC 1512 FDDI MIB September 1993
FddimibMACCountersEntry ::=
SEQUENCE {
fddimibMACTokenCts
Counter,
fddimibMACTvxExpiredCts
Counter,
fddimibMACNotCopiedCts
Counter,
fddimibMACLateCts
Counter,
fddimibMACRingOpCts
Counter,
fddimibMACNotCopiedRatio
INTEGER,
fddimibMACNotCopiedFlag
INTEGER,
fddimibMACNotCopiedThreshold
INTEGER
}
fddimibMACTokenCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of times the station has received a
token (total of non-restricted and restricted) on
this MAC (see ANSI MAC 7.4). This count is
valuable for determination of network load."
REFERENCE
"ANSI { fddiMAC 74 }"
::= { fddimibMACCountersEntry 1 }
fddimibMACTvxExpiredCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of times that TVX has expired."
REFERENCE
"ANSI { fddiMAC 83 }"
::= { fddimibMACCountersEntry 2 }
fddimibMACNotCopiedCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
Case & Rijsinghani [Page 30]
^L
RFC 1512 FDDI MIB September 1993
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of frames that were addressed to this
MAC but were not copied into its receive buffers
(see ANSI MAC 7.5). For example, this might occur
due to local buffer congestion. Because of
implementation considerations, this count may not
match the actual number of frames not copied. It
is not a requirement that this count be exact.
Note that this count does not include MAC frames."
REFERENCE
"ANSI { fddiMAC 84 }"
::= { fddimibMACCountersEntry 3 }
fddimibMACLateCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match
the number of TRT expirations since this MAC was
reset or a token was received (refer to ANSI MAC
7.4.5)."
REFERENCE
"ANSI { fddiMAC 85 }"
::= { fddimibMACCountersEntry 4 }
fddimibMACRingOpCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of the number of times the ring has
entered the 'Ring_Operational' state from the
'Ring Not Operational' state. This count is
updated when a SM_MA_STATUS.Indication of a change
in the Ring_Operational status occurs (refer to
ANSI 6.1.4). Because of implementation
considerations, this count may be less than the
actual RingOp_Ct. It is not a requirement that
this count be exact."
REFERENCE
"ANSI { fddiMAC 86 }"
::= { fddimibMACCountersEntry 5 }
fddimibMACNotCopiedRatio OBJECT-TYPE
SYNTAX INTEGER (0..65535)
Case & Rijsinghani [Page 31]
^L
RFC 1512 FDDI MIB September 1993
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is the value of the ratio:
(delta fddiMACNotCopiedCts /
(delta fddiMACCopiedCts +
delta fddiMACNotCopiedCts )) * 2**16 "
REFERENCE
"ANSI { fddiMAC 105 }"
::= { fddimibMACCountersEntry 6 }
fddimibMACNotCopiedFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates that the Not Copied condition is
present when read as true(1). Set to false(2)
when the condition clears and on station
initialization."
REFERENCE
"ANSI { fddiMAC 115 }"
::= { fddimibMACCountersEntry 7 }
fddimibMACNotCopiedThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A threshold for determining when a MAC condition
report shall be generated. Stations not
supporting variable thresholds shall have a value
of 0 and a range of (0..0)."
REFERENCE
"ANSI { fddiMAC 103 }"
::= { fddimibMACCountersEntry 8 }
-- the PATH group
-- Implementation of the PATH group is mandatory for all
-- systems which implement manageable FDDI subsystems.
fddimibPATHNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
Case & Rijsinghani [Page 32]
^L
RFC 1512 FDDI MIB September 1993
"The total number of PATHs possible (across all
SMTs) on this network management application
entity. The value for this variable must remain
constant at least from one re-initialization of
the entity's network management system to the next
re-initialization."
::= { fddimibPATH 1 }
-- the PATH table
fddimibPATHTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibPATHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PATH entries. The number of entries
shall not exceed the value of fddimibPATHNumber."
::= { fddimibPATH 2 }
fddimibPATHEntry OBJECT-TYPE
SYNTAX FddimibPATHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A PATH entry containing information common to a
given PATH."
INDEX { fddimibPATHSMTIndex, fddimibPATHIndex }
::= { fddimibPATHTable 1 }
FddimibPATHEntry ::=
SEQUENCE {
fddimibPATHSMTIndex
INTEGER,
fddimibPATHIndex
INTEGER,
fddimibPATHTVXLowerBound
FddiTimeNano,
fddimibPATHTMaxLowerBound
FddiTimeNano,
fddimibPATHMaxTReq
FddiTimeNano
}
fddimibPATHSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
Case & Rijsinghani [Page 33]
^L
RFC 1512 FDDI MIB September 1993
DESCRIPTION
"The value of the SMT index associated with this
PATH."
::= { fddimibPATHEntry 1 }
fddimibPATHIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the
primary, secondary and local PATH object
instances. Local PATH object instances are
represented with integer values 3 to 255."
REFERENCE
"ANSI { fddiPATH 11 }"
::= { fddimibPATHEntry 2 }
fddimibPATHTVXLowerBound OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the minimum time value of
fddiMACTvxValue that shall be used by any MAC that
is configured in this path. The operational value
of fddiMACTvxValue is managed by settting this
variable. This variable has the time value range
of:
0 < fddimibPATHTVXLowerBound < fddimibPATHMaxTReq
Changes to this variable shall either satisfy the
time value relationship:
fddimibPATHTVXLowerBound <=
fddimibMACTVXCapability
of each of the MACs currently on the path, or be
considered out of range. The initial value of
fddimibPATHTVXLowerBound shall be 2500 nsec (2.5
ms)."
REFERENCE
"ANSI { fddiPATH 21 }"
::= { fddimibPATHEntry 3 }
fddimibPATHTMaxLowerBound OBJECT-TYPE
SYNTAX FddiTimeNano
Case & Rijsinghani [Page 34]
^L
RFC 1512 FDDI MIB September 1993
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the minimum time value of fddiMACTMax
that shall be used by any MAC that is configured
in this path. The operational value of
fddiMACTMax is managed by setting this variable.
This variable has the time value range of:
fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound
and an absolute time value range of:
10000nsec (10 msec) <= fddimibPATHTMaxLowerBound
Changes to this variable shall either satisfy the
time value relationship:
fddimibPATHTMaxLowerBound <
fddimibMACTMaxCapability
of each of the MACs currently on the path, or be
considered out of range. The initial value of
fddimibPATHTMaxLowerBound shall be 165000 nsec
(165 msec)."
REFERENCE
"ANSI { fddiPATH 22 }"
::= { fddimibPATHEntry 4 }
fddimibPATHMaxTReq OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the maximum time value of fddiMACT-Req
that shall be used by any MAC that is configured
in this path. The operational value of fddiMACT-
Req is managed by setting this variable. This
variable has the time value range of:
fddimibPATHTVXLowerBound < fddimibPATHMaxTReq <=
fddimibPATHTMaxLowerBound.
The default value of fddimibPATHMaxTReq is 165000
nsec (165 msec)."
REFERENCE
"ANSI { fddiPATH 23 }"
::= { fddimibPATHEntry 5 }
Case & Rijsinghani [Page 35]
^L
RFC 1512 FDDI MIB September 1993
-- the PATH Configuration table
fddimibPATHConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibPATHConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Path configuration entries. This
table lists all the resources that may be in this
Path."
REFERENCE
"ANSI { fddiPATH 18 }"
::= { fddimibPATH 3 }
fddimibPATHConfigEntry OBJECT-TYPE
SYNTAX FddimibPATHConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A collection of objects containing information
for a given PATH Configuration entry."
INDEX { fddimibPATHConfigSMTIndex,
fddimibPATHConfigPATHIndex,
fddimibPATHConfigTokenOrder }
::= { fddimibPATHConfigTable 1 }
FddimibPATHConfigEntry ::=
SEQUENCE {
fddimibPATHConfigSMTIndex
INTEGER,
fddimibPATHConfigPATHIndex
INTEGER,
fddimibPATHConfigTokenOrder
INTEGER,
fddimibPATHConfigResourceType
INTEGER,
fddimibPATHConfigResourceIndex
INTEGER,
fddimibPATHConfigCurrentPath
INTEGER
}
fddimibPATHConfigSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the SMT index associated with this
Case & Rijsinghani [Page 36]
^L
RFC 1512 FDDI MIB September 1993
configuration entry."
::= { fddimibPATHConfigEntry 1 }
fddimibPATHConfigPATHIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the PATH resource index associated
with this configuration entry."
::= { fddimibPATHConfigEntry 2 }
fddimibPATHConfigTokenOrder OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An object associated with Token order for this
entry. Thus if the token passes resources a, b, c
and d, in that order, then the value of this
object for these resources would be 1, 2, 3 and 4
respectively."
::= { fddimibPATHConfigEntry 3 }
fddimibPATHConfigResourceType OBJECT-TYPE
SYNTAX INTEGER { mac(2), port(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of resource associated with this
configuration entry."
::= { fddimibPATHConfigEntry 4 }
fddimibPATHConfigResourceIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the SMT resource index used to refer
to the instance of this MAC or Port resource."
::= { fddimibPATHConfigEntry 5 }
fddimibPATHConfigCurrentPath OBJECT-TYPE
SYNTAX INTEGER {
isolated(1), local(2), secondary(3), primary(4),
concatenated(5), thru(6)
}
ACCESS read-only
Case & Rijsinghani [Page 37]
^L
RFC 1512 FDDI MIB September 1993
STATUS mandatory
DESCRIPTION
"The current insertion status for this resource on
this Path."
::= { fddimibPATHConfigEntry 6 }
-- the PORT group
-- Implementation of the PORT group is mandatory for all
-- systems which implement manageable FDDI subsystems.
fddimibPORTNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of PORT implementations (across
all SMTs) on this network management application
entity. The value for this variable must remain
constant at least from one re-initialization of
the entity's network management system to the next
re-initialization."
::= { fddimibPORT 1 }
-- the PORT table
fddimibPORTTable OBJECT-TYPE
SYNTAX SEQUENCE OF FddimibPORTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PORT entries. The number of entries
shall not exceed the value of fddimibPORTNumber."
::= { fddimibPORT 2 }
fddimibPORTEntry OBJECT-TYPE
SYNTAX FddimibPORTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A PORT entry containing information common to a
given PORT."
INDEX { fddimibPORTSMTIndex, fddimibPORTIndex }
::= { fddimibPORTTable 1 }
FddimibPORTEntry ::=
SEQUENCE {
Case & Rijsinghani [Page 38]
^L
RFC 1512 FDDI MIB September 1993
fddimibPORTSMTIndex
INTEGER,
fddimibPORTIndex
INTEGER,
fddimibPORTMyType
INTEGER,
fddimibPORTNeighborType
INTEGER,
fddimibPORTConnectionPolicies
INTEGER,
fddimibPORTMACIndicated
INTEGER,
fddimibPORTCurrentPath
INTEGER,
fddimibPORTRequestedPaths
OCTET STRING,
fddimibPORTMACPlacement
FddiResourceId,
fddimibPORTAvailablePaths
INTEGER,
fddimibPORTPMDClass
INTEGER,
fddimibPORTConnectionCapabilities
INTEGER,
fddimibPORTBSFlag
INTEGER,
fddimibPORTLCTFailCts
Counter,
fddimibPORTLerEstimate
INTEGER,
fddimibPORTLemRejectCts
Counter,
fddimibPORTLemCts
Counter,
fddimibPORTLerCutoff
INTEGER,
fddimibPORTLerAlarm
INTEGER,
fddimibPORTConnectState
INTEGER,
fddimibPORTPCMState
INTEGER,
fddimibPORTPCWithhold
INTEGER,
fddimibPORTLerFlag
INTEGER,
fddimibPORTHardwarePresent
INTEGER,
Case & Rijsinghani [Page 39]
^L
RFC 1512 FDDI MIB September 1993
fddimibPORTAction
INTEGER
}
fddimibPORTSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the SMT index associated with this
PORT."
::= { fddimibPORTEntry 1 }
fddimibPORTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each PORT within a given SMT,
which is the same as the corresponding resource
index in SMT. The value for each PORT must remain
constant at least from one re-initialization of
the entity's network management system to the next
re-initialization."
REFERENCE
"ANSI { fddiPORT 29 }"
::= { fddimibPORTEntry 2 }
fddimibPORTMyType OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the PORT's PC_Type (refer to ANSI
9.4.1, and 9.6.3.2)."
REFERENCE
"ANSI { fddiPORT 12 }"
::= { fddimibPORTEntry 3 }
fddimibPORTNeighborType OBJECT-TYPE
SYNTAX INTEGER { a(1), b(2), s(3), m(4), none(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the remote PORT as determined in PCM.
This variable has an initial value of none, and is
only modified in PC_RCode(3)_Actions (refer to
ANSI SMT 9.6.3.2)."
Case & Rijsinghani [Page 40]
^L
RFC 1512 FDDI MIB September 1993
REFERENCE
"ANSI { fddiPORT 13 }"
::= { fddimibPORTEntry 4 }
fddimibPORTConnectionPolicies OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value representing the PORT's connection
policies desired in the node. The value of pc-
mac-lct is a term used in the PC_MAC_LCT Flag (see
9.4.3.2). The value of pc-mac-loop is a term used
in the PC_MAC_Loop Flag.
The value is a sum. This value initially takes
the value zero, then for each PORT policy, 2
raised to a power is added to the sum. The powers
are according to the following table:
Policy Power
pc-mac-lct 0
pc-mac-loop 1 "
REFERENCE
"ANSI { fddiPORT 14 }"
::= { fddimibPORTEntry 5 }
fddimibPORTMACIndicated OBJECT-TYPE
SYNTAX INTEGER {
tVal9FalseRVal9False(1),
tVal9FalseRVal9True(2),
tVal9TrueRVal9False(3),
tVal9TrueRVal9True(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The indications (T_Val(9), R_Val(9)) in PC-
Signalling, of the intent to place a MAC in the
output token path to a PORT (refer to ANSI SMT
9.6.3.2.)."
REFERENCE
"ANSI { fddiPORT 15 }"
::= { fddimibPORTEntry 6 }
fddimibPORTCurrentPath OBJECT-TYPE
SYNTAX INTEGER {
ce0(1), -- isolated
Case & Rijsinghani [Page 41]
^L
RFC 1512 FDDI MIB September 1993
ce1(2), -- local
ce2(3), -- secondary
ce3(4), -- primary
ce4(5), -- concatenated
ce5(6) -- thru
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the Path(s) into which this PORT is
currently inserted."
REFERENCE
"ANSI { fddiPORT 16 }"
::= { fddimibPORTEntry 7 }
fddimibPORTRequestedPaths OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is a list of permitted Paths where
each list element defines the Port's permitted
Paths. The first octet corresponds to 'none', the
second octet to 'tree', and the third octet to
'peer'."
REFERENCE
"ANSI { fddiPORT 17 }"
::= { fddimibPORTEntry 8 }
fddimibPORTMACPlacement OBJECT-TYPE
SYNTAX FddiResourceId -- INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the MAC, if any, whose transmit path
exits the station via this PORT. The value shall
be zero if there is no MAC associated with the
PORT. Otherwise, the MACIndex of the MAC will be
the value of the variable."
REFERENCE
"ANSI { fddiPORT 18 }"
::= { fddimibPORTEntry 9 }
fddimibPORTAvailablePaths OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
Case & Rijsinghani [Page 42]
^L
RFC 1512 FDDI MIB September 1993
"Indicates the Paths which are available to this
Port. In the absence of faults, the A and B Ports
will always have both the Primary and Secondary
Paths available.
The value is a sum. This value initially takes
the value zero, then for each type of PATH that
this port has available, 2 raised to a power is
added to the sum. The powers are according to the
following table:
Path Power
Primary 0
Secondary 1
Local 2 "
REFERENCE
"ANSI { fddiPORT 19 }"
::= { fddimibPORTEntry 10 }
fddimibPORTPMDClass OBJECT-TYPE
SYNTAX INTEGER {
multimode(1),
single-mode1(2),
single-mode2(3),
sonet(4),
low-cost-fiber(5),
twisted-pair(6),
unknown(7),
unspecified(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the type of PMD entity
associated with this port."
REFERENCE
"ANSI { fddiPORT 22 }"
::= { fddimibPORTEntry 11 }
fddimibPORTConnectionCapabilities OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that indicates the connection
capabilities of the port. The pc-mac-lct bit
indicates that the station has the capability of
setting the PC_MAC_LCT Flag. The pc-mac-loop bit
Case & Rijsinghani [Page 43]
^L
RFC 1512 FDDI MIB September 1993
indicates that the station has the capability of
setting the PC_MAC_Loop Flag (refer to ANSI
9.4.3.2).
The value is a sum. This value initially takes
the value zero, then for each capability that this
port has, 2 raised to a power is added to the sum.
The powers are according to the following table:
capability Power
pc-mac-lct 0
pc-mac-loop 1 "
REFERENCE
"ANSI { fddiPORT 23 }"
::= { fddimibPORTEntry 12 }
fddimibPORTBSFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable assumes the value of the BS_Flag
(refer to ANSI SMT 9.4.3.3)."
REFERENCE
"ANSI { fddiPORT 33 }"
::= { fddimibPORTEntry 13 }
fddimibPORTLCTFailCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The count of the consecutive times the link
confidence test (LCT) has failed during connection
management (refer to ANSI 9.4.1)."
REFERENCE
"ANSI { fddiPORT 42 }"
::= { fddimibPORTEntry 14 }
fddimibPORTLerEstimate OBJECT-TYPE
SYNTAX INTEGER (4..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A long term average link error rate. It ranges
from 10**-4 to 10**-15 and is reported as the
absolute value of the base 10 logarithm (refer to
ANSI SMT 9.4.7.5.)."
Case & Rijsinghani [Page 44]
^L
RFC 1512 FDDI MIB September 1993
REFERENCE
"ANSI { fddiPORT 51 }"
::= { fddimibPORTEntry 15 }
fddimibPORTLemRejectCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A link error monitoring count of the times that a
link has been rejected."
REFERENCE
"ANSI { fddiPORT 52 }"
::= { fddimibPORTEntry 16 }
fddimibPORTLemCts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The aggregate link error monitor error count, set
to zero only on station initialization."
REFERENCE
"ANSI { fddiPORT 53 }"
::= { fddimibPORTEntry 17 }
fddimibPORTLerCutoff OBJECT-TYPE
SYNTAX INTEGER (4..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The link error rate estimate at which a link
connection will be broken. It ranges from 10**-4
to 10**-15 and is reported as the absolute value
of the base 10 logarithm (default of 7)."
REFERENCE
"ANSI { fddiPORT 58 }"
::= { fddimibPORTEntry 18 }
fddimibPORTLerAlarm OBJECT-TYPE
SYNTAX INTEGER (4..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The link error rate estimate at which a link
connection will generate an alarm. It ranges from
10**-4 to 10**-15 and is reported as the absolute
value of the base 10 logarithm of the estimate
Case & Rijsinghani [Page 45]
^L
RFC 1512 FDDI MIB September 1993
(default of 8)."
REFERENCE
"ANSI { fddiPORT 59 }"
::= { fddimibPORTEntry 19 }
fddimibPORTConnectState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
connecting(2),
standby(3),
active(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of the connect state of this PORT
and is equal to the value of Connect_State (refer
to ANSI 9.4.1)"
REFERENCE
"ANSI { fddiPORT 61 }"
::= { fddimibPORTEntry 20 }
fddimibPORTPCMState OBJECT-TYPE
SYNTAX INTEGER {
pc0(1), -- Off
pc1(2), -- Break
pc2(3), -- Trace
pc3(4), -- Connect
pc4(5), -- Next
pc5(6), -- Signal
pc6(7), -- Join
pc7(8), -- Verify
pc8(9), -- Active
pc9(10) -- Maint
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of this Port's PCM state machine refer
to ANSI SMT 9.6.2)."
REFERENCE
"ANSI { fddiPORT 62 }"
::= { fddimibPORTEntry 21 }
fddimibPORTPCWithhold OBJECT-TYPE
SYNTAX INTEGER {
none(1),
m-m(2),
Case & Rijsinghani [Page 46]
^L
RFC 1512 FDDI MIB September 1993
otherincompatible(3),
pathnotavailable(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of PC_Withhold (refer to ANSI SMT
9.4.1)."
REFERENCE
"ANSI { fddiPORT 63 }"
::= { fddimibPORTEntry 22 }
fddimibPORTLerFlag OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The condition becomes active when the value of
fddiPORTLerEstimate is less than or equal to
fddiPORTLerAlarm. This will be reported with the
Status Report Frames (SRF) (refer to ANSI SMT
7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiPORT 64 }"
::= { fddimibPORTEntry 23 }
fddimibPORTHardwarePresent OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the presence of
underlying hardware support for this Port object.
If the value of this object is false(2), the
reporting of the objects in this entry may be
handled in an implementation-specific manner."
REFERENCE
"ANSI { fddiPORT 65 }"
::= { fddimibPORTEntry 24 }
fddimibPORTAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
maintPORT(2),
enablePORT(3),
disablePORT(4),
startPORT(5),
stopPORT(6)
Case & Rijsinghani [Page 47]
^L
RFC 1512 FDDI MIB September 1993
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Causes a Control signal to be generated with a
control_action of 'Signal' and the 'variable'
parameter set with the appropriate value (i.e.,
PC_Maint, PC_Enable, PC_Disable, PC_Start, or
PC_Stop) (refer to ANSI 9.4.2)."
REFERENCE
"ANSI { fddiPORT 70 }"
::= { fddimibPORTEntry 25 }
END
5. Acknowledgements
This document was produced by the IETF FDDI MIB working group:
Hossein Alaee, 3Com Corporation
Haggar Alsaleh, Bell Northern Research
William Anderson, Mitre Corporation
Alan Apt, Addison-Wesley
Mary Artibee, Silicon Graphics
Karen Auerbach, Epilogue Technologies
Doug Bagnall, Apollo/Hewlett Packard
Chet Birger, Coral Network Corporation
Pablo Brenner, Fibronics
Howard Brown, Cabletron
Jack Brown, US Army Computer Engineering Center
Eric Brunner
Jeff Case, The University of Tennessee
Tammy Chan, Fibercom
Asheem Chandna, AT&T
Cho Y. Chang, Apollo/Hewlett Packard
Chris Chiotasso, Fibronics
Paul Ciarfella, Digital Equipment Corporation
John Cook, Chipcom
Don Coolidge, Silicon Graphics
Burt Cyr, Unisys
James R. Davin, Massachusetts Institute of Technology
Nabil Damouny
Nadya El-Afandi, Network Systems Corporation
Hunaid Engineer, Cray Research
Jeff Fitzgerald, Fibercom
Richard Fox, Synoptics
Stan Froyd, ACC
Case & Rijsinghani [Page 48]
^L
RFC 1512 FDDI MIB September 1993
Debbie Futcher, U.S. Naval Surface Warfare Center
Joseph Golio, Cray Research
Jeremy Greene, Coral
Peter Hayden, Digital Equipment Corporation
Scott Hiles, U.S. Naval Surface Warfare Center
Greg Jones, Data General
Satish Joshi, SynOptics Communications
Jayant Kadambi, AT&T Bell Labs
Joanna Karwowska, Data General
Frank Kastenholz, Interlan
Jim Kinder, Fibercom
Christopher Kolb, PSI
Cheryl Krupczak, NCR
Peter Lin, Vitalink
Then Liu
John R. LoVerso, Concurrent Computer Corporation
Ron Mackey, Distributed Systems International, Inc.
Gary Malkin, Proteon
Bruce McClure, Synernetics
Keith McCloghrie, Hughes Lan Systems
Donna McMaster, SynOptics
John O'Hara, Massachusetts Institute of Technology
Luc Pariseau, Digital Equipment Corporation
Dave Perkins, SynOptics Communications
James E. Reeves, SynOptics Communications
Jim Reinstedler, Ungermann-Bass
Radhi Renous, Fibronics
Sal Ricci, AT&T/NCR
Anil Rijsinghani, Digital Equipment Corporation
Bob Rolla, Synernetics
Nelson Ronkin, Synernetics
Marshall T. Rose, Performance Systems International, Inc.
Milt Roselinsky, CMC
Jon Saperia, Digital Equipment Corporation
Greg Satz, cisco Systems
Steven Senum, Network Systems Corporation
Jim Sheridan, IBM Corporation
Jeffrey Schiller, MIT
Dror Shindelman, Fibronics
Mark Sleeper, Sparta
Lou Steinberg, IBM Corporation
Larry Stefani, Digital Equipment Corporation
Mary Jane Strohl, Apollo/Hewlett Packard
Sally Tarquinio, Mitre Corporation
Kaj Tesink, Bellcore
Ian Thomas, Chipcom
Dean Throop, Data General
Bill Townsend, Xylogics
Case & Rijsinghani [Page 49]
^L
RFC 1512 FDDI MIB September 1993
Ahmet H. Tuncay, SynOptics Communications
Mike Turico, Motorola
Chris VandenBerg, ACC
Sudhanshu Verma, Hewlett Packard
Joe Vermeulen, UNISYS
David Waiteman, BBN
Bert Williams, Synernetics
Mark Wood, Distributed Systems International, Inc.
Y. C. Yang
Denis Yaro, Sun Microsystems
Jeff Young, Cray Research
The author gratefully acknowledges the labors of Judi Talley and
David Reid of SNMP Research, Inc. for their editorial assistance in
the preparation of this document.
6. References
[1] Rose M., and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based internets", STD 16, RFC
1155, Performance Systems International, Hughes LAN Systems, May
1990.
[2] Case, J., "FDDI Management Information Base", RFC 1285, SNMP
Research, Incorporated, January 1992.
[3] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
Network Management Protocol", STD 15, RFC 1157, SNMP Research,
Performance Systems International, Performance Systems
International, MIT Laboratory for Computer Science, May 1990.
[4] McCloghrie K., and M. Rose, Editors, "Management Information
Base for Network Management of TCP/IP-based internets", STD 17,
RFC 1213, Performance Systems International, March 1991.
[5] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1),
International Organization for Standardization. International
Standard 8824, (December, 1987).
[6] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One
(ASN.1), International Organization for Standardization.
International Standard 8825, (December, 1987).
[7] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
STD 16, RFC 1212, Performance Systems International, Hughes LAN
Systems, March 1991.
Case & Rijsinghani [Page 50]
^L
RFC 1512 FDDI MIB September 1993
[8] American National Standards Institute, FDDI Station Management
(SMT), Draft Proposed American National Standard, American
National Standards Institute, X3T9.5/84-49 REV 7.3.
7. Security Considerations
Security issues are not discussed in this memo.
8. Authors' Addresses
Jeffrey D. Case
The University of Tennessee
Department of Computer Science
107 Ayres Hall
Knoxville, Tennessee 37996
and
SNMP Research, Incorporated
3001 Kimberlin Heights Road
Knoxville, Tennessee 37920
Phone: (615) 974-5067 or (615) 573-1434
EMail: case@CS.UTK.EDU
Anil Rijsinghani
Digital Equipment Corporation
295 Foster Street
Littleton, MA 01460-1123
Phone: (508) 952-3520
EMail: anil@levers.enet.dec.com
Case & Rijsinghani [Page 51]
^L
|