summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc1795.txt
blob: 9282d14376b59f7ab2015e5fe53879e619a1fb9b (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
Network Working Group                                    L. Wells, Chair
Request for Comments: 1795             Internetwork Technology Institute
Obsoletes: 1434                                        A. Bartky, Editor
Category: Informational                              Sync Research, Inc.
                                                              April 1995


             Data Link Switching: Switch-to-Switch Protocol
       AIW DLSw RIG: DLSw Closed Pages, DLSw Standard Version 1.0

Status of this Memo

   This memo provides information for the Internet community.  This memo
   does not specify an Internet standard of any kind.  Distribution of
   this memo is unlimited.

Abstract

   This RFC describes use of Data Link Switching over TCP/IP. The RFC is
   being distributed to members of the Internet community in order to
   solicit their reactions to the proposals contained in it.  While the
   issues discussed may not be directly relevant to the research
   problems of the Internet, they may be interesting to a number of
   researchers and Implementers.

   This RFC was created as a joint effort of the Advanced Peer-to-Peer
   Networking (APPN) Implementers Workshop (AIW) Data Link Switching
   (DLSw) Related Interest Group (RIG).  The APPN Implementers Workshop
   is a group sponsored by IBM and consists of representatives of member
   companies implementing current and future IBM Networking
   interoperable products. The DLSw Related Interest Group was formed in
   this forum in order to produce a single version of the Switch to
   Switch Protocol (SSP) which could be implemented by all vendors,
   which would fix documentation problems with the existing RFC 1434,
   and which would enhance and evolve the protocol to add new functions
   and features.

   This document is based on RFC 1434.  This document contains
   significant changes to RFC 1434 and therefore obsoletes that
   document.

   Any questions or comments relative to the contents of this RFC should
   be sent to the following Internet address:
   aiw-dlsw@networking.raleigh.ibm.com.

   NOTE 1: This is a widely subscribed mailing list and messages sent to
   this address will be sent to all members of the DLSw mailing list.
   For specific questions relating to subscribing to the AIW and any of



Wells & Bartky                                                  [Page 1]
^L
RFC 1795                  Data Link Switching                 April 1995


   it's working groups send email to: appn@vnet.ibm.com

   Information regarding all of the AIW working groups and the work they
   are producing can be obtained by copying, via anonymous ftp, the file
   aiwinfo.psbin or aiwinfo.txt from the Internet host
   networking.raleigh.ibm.com, located in directory aiw.

   NOTE 2:  These mailing lists and addresses are subject to change.

1.  Introduction

   Data Link Switching (DLSw) is a forwarding mechanism for the IBM SNA
   (Systems Network Architecture) and IBM NetBIOS (Network Basic Input
   Output Services) protocols.  This memo documents the Switch-to-Switch
   Protocol (SSP) that is used between Data Link Switches.  This
   protocol does not provide full routing, but instead provides
   switching at the SNA Data Link layer (i.e., layer 2 in the SNA
   architecture) and encapsulation in TCP/IP for transport over the
   Internet.  This RFC documents the frame formats and protocols for
   multiplexing data between Data Link Switches. The initial
   implementation of SSP uses TCP as the reliable transport between Data
   Link Switches.  However, other transport connections such as OSI TP4
   could be used in the future.

   A Data Link Switch (abbreviated also as DLSw in this document) can
   support  SNA (Physical Unit (PU) 2, PU 2.1 and PU 4) systems and
   optionally NetBIOS systems attached to IEEE 802.2 compliant Local
   Area Networks, as well as SNA (PU 2 (primary or secondary) and PU2.1)
   systems attached to IBM Synchronous Data Link Control (SDLC) links.
   For the latter case, the SDLC attached systems are provided with a
   LAN appearance within the Data Link Switch (each SDLC PU is presented
   to the SSP protocol as a unique MAC/SAP address pair).  For the
   Token-Ring LAN attached systems, the Data Link Switch appears as a
   source-routing bridge.  Token-Ring Remote systems that are accessed
   through the Data Link Switch appear as systems attached to an
   adjacent ring.  This ring is a virtual ring that is manifested within
   each Data Link Switch.

1.1  Backwards Compatibility with RFC 1434

   This document defines significant changes to RFC 1434 and does not
   state details on how to interoperate with RFC 1434 or "enhanced"
   implementations (e.g., those that added enter and exit busy flow
   control).  It is up to the implementer to refer to RFC 1434 and/or
   any other vendor's documentation in order to interoperate with a
   given vendor's implementation, if interoperability with pre-AIW DLSw
   RIG standards is desired.




Wells & Bartky                                                  [Page 2]
^L
RFC 1795                  Data Link Switching                 April 1995


2.  Overview

   Data Link Switching was developed to provide support for SNA and
   NetBIOS in multi-protocol routers.  Since SNA and NetBIOS are
   basically connection oriented protocols, the Data Link Control
   procedure that they use on the LAN is IEEE 802.2 Logical Link Control
   (LLC) Type 2.  Data Link Switching also accommodates SNA protocols
   over WAN (Wide Area Network) links via the SDLC protocol.

   IEEE 802.2 LLC Type 2 was designed with the assumption that the
   network transit delay would be predictable (i.e., a local LAN).
   Therefore the LLC Type 2 elements of procedure use a fixed timer for
   detecting lost frames.  When remote bridging is used over wide area
   lines (especially at lower speeds), the network delay is larger and
   it can vary greatly based upon congestion.  When the delay exceeds
   the time-out value LLC Type 2 attempts to retransmit.  If the frame
   is not actually lost, only delayed, it is possible for the LLC Type 2
   procedures to become confused.  And as a result, the link may be
   eventually taken down if the delay exceeds the T1 timer times N2
   retry count.

   Given the use of LLC Type 2 services, Data Link Switching addresses
   the following bridging problems:

             DLC Time-outs
             DLC Acknowledgments over the WAN
             Flow and Congestion Control
             Broadcast Control of Search Packets
             Source-Route Bridging Hop Count Limits

   NetBIOS also makes extensive use of datagram services that use
   connectionless LLC Type 1 service.  In this case, Data Link Switching
   addresses the last two problems in the above list.

   The principal difference between Data Link Switching and bridging is
   that for connection-oriented data DLSw terminates the Data Link Control
   whereas bridging does not. The following figure illustrates this
   difference based upon two end systems operating with LLC Type 2
   services.












Wells & Bartky                                                  [Page 3]
^L
RFC 1795                  Data Link Switching                 April 1995


   Bridging
   --------

                    Bridge           Bridge
   +------+         +----+           +----+         +------+
   | End  | +-----+ |    +-----/     |    | +-----+ | End  |
   |System+-+ LAN +-+    |    /------+    +-+ LAN +-+System|
   |      | +-----+ |    |  TCP/IP   |    | +-----+ |      |
   +------+         +----+           +----+         +------+
      Info----------------------------------------------->
          <-----------------------------------------------RR


   Data Link Switching
   -------------------

   +------+         +----+           +----+         +------+
   | End  | +-----+ |    +-----/     |    | +-----+ | End  |
   |System+-+ LAN +-+DLSw|    /------+DLSw+-+ LAN +-+System|
   |      | +-----+ |    |  TCP/IP   |    | +-----+ |      |
   +------+         +----+           +----+         +------+
    Info--------------->   -------------> Info
      <---------------RR                 ------------>
                                         <------------RR

   In traditional bridging, the Data Link Control is end-to-end.  Data
   Link Switching terminates the LLC Type 2 connection at the switch.
   This means that the LLC Type 2 connections do not cross the wide area
   network.  The DLSw multiplexes LLC connections onto a TCP connection
   to another DLSw.  Therefore, the LLC connections at each end are
   totally independent of each other.  It is the responsibility of the
   Data Link Switch to deliver frames that it has received from a LLC
   connection to the other end.  TCP is used between the Data Link
   Switches to guarantee delivery of frames.

   As a result of this design, LLC time-outs are limited to the local
   LAN (i.e., they do not traverse the wide area).  Also, the LLC Type 2
   acknowledgments (RR's) do not traverse the WAN, thereby reducing
   traffic across the wide area links.  For SDLC links, polling and poll
   response occurs locally, not over the WAN.  Broadcast of search
   frames is controlled by the Data Link Switches once the location of a
   target system is discovered.  Finally, the switches can now apply
   back pressure to the end systems to provide flow and congestion
   control.

   Only one copy of an Link Protocol Data Unit (LPDU) is sent between
   Data Link Switches in SSP messages (XIDFRAME and INFOFRAME).  Retries
   of the LPDU are absorbed by Data Link Switch that receives it.  The



Wells & Bartky                                                  [Page 4]
^L
RFC 1795                  Data Link Switching                 April 1995


   Data Link Switch that transmits the LPDU received in an SSP message
   to a local DLC, will perform retries in a manner appropriate for the
   local DLC. This may involve running a reply timer and maintaining a
   poll retry count.  The length of the timer and the number of retries
   is an implementation choice based on user configuration parameters
   and the DLC type.

   Data Link Switching uses LAN addressing to set up connections between
   SNA systems.  SDLC attached devices are defined with MAC and SAP
   addresses to enable them to communicate with LAN attached devices.
   For NetBIOS systems, Data Link Switching uses the NetBIOS name to
   forward datagrams and to set up connections for NetBIOS sessions.
   For LLC type 2 connection establishment, SNA systems send TEST (or in
   some cases, XID) frames to the null (0x00) SAP.  NetBIOS systems have
   an address resolution procedure, based upon the Name Query and Name
   Recognized frames, that is used to establish an end-to-end circuit.

   Since Data Link Switching may be implemented in multi-protocol
   routers, there may be situations where both bridging and switching
   are enabled. SNA frames can be identified by their link SAP.  Typical
   SAP values for SNA are 0x04, 0x08, and 0x0C.  NetBIOS always uses a
   link SAP value of 0xF0.





























Wells & Bartky                                                  [Page 5]
^L
RFC 1795                  Data Link Switching                 April 1995


3.  Transport Connection

   Data Link Switches can be in used in pairs or by themselves.

   A Single DLSw internally switches one data link to another without
   using TCP (DLC(1) to DLC(2) in the figure below).  This RFC does not
   go into details on how to implement this feature and it is not a
   requirement to support this RFC.

   A paired DLSw multiplexes data links over a reliable transport using
   a Switch-to-Switch Protocol (SSP).

   +-------------------------------------------+Switch-to-Switch
   |              DLC Interfaces               | Protocol (SSP)
   |+-----------+   DLC Request  +-----------+ |
   ||   Data    |<---------------|           | |Send SSP Frame
   ||   Link    | DLC Indication |           | |-------------->
   || Control 1 |--------------->|           | |
   |+-----------+                | Data Link | |
   |+-----------+   DLC Request  |  Switch   | |
   ||   Data    |<-------------- |           | |Rec. SSP Frame
   ||   Link    | DLC Indication |           | |<-------------
   || Control 2 | -------------->|           | |
   |+-----------+                +-----------+ |
   |            Multi-Protocol Router          |
   +-------------------------------------------+

   Before Data Link Switching can occur between two routers, they must
   establish two TCP connections between them.  Each Data Link Switch
   will maintain a list of DLSw capable routers and their status
   (active/inactive).  After the TCP connection is established, SSP
   messages are exchanged to establish the capabilities of the two Data
   Link Switches.  Once the exchange is complete,  the DLSw will employ
   SSP control messages to establish end-to-end circuits over the
   transport connection.  Within the transport connection, DLSw SSP
   messages are exchanged.  The message formats and types for these SSP
   messages are documented in the following sections.

   The default parameters associated with the TCP connections between
   Data Link Switches are as follows:

   Socket Family     AF_INET        (Internet protocols)
   Socket Type       SOCK_STREAM    (stream socket)
   Read Port Number  2065
   Write Port Number 2067






Wells & Bartky                                                  [Page 6]
^L
RFC 1795                  Data Link Switching                 April 1995


   Two or more Data Link Switches may be attached to the same LAN,
   consisting of a number of token-ring segments interconnected by
   source-routing bridges.  In this case, a TCP connection is not
   defined between bridges attached to the same LAN.  This will allow
   using systems to select one of the possible Data Link Switches in a
   similar manner to the selection of a bridge path through a source-
   routed bridged network.  The virtual ring segment in each Data Link
   Switch attached to a common LAN must be configured with the same ring
   number.  This will prevent LAN frames sent by one Data Link Switch
   from being propagated through the other Data Link Switches.









































Wells & Bartky                                                  [Page 7]
^L
RFC 1795                  Data Link Switching                 April 1995


3.1  SSP Frame Formats

   The following diagrams show the two message header formats exchanged
   between Data Link Switches, Control and Information.  The Control
   message header is used for all messages except Information Frames
   (INFOFRAME) and Independent Flow Control Messages (IFCM), which are
   sent in Information header format.  The INFOFRAME, KEEPALIVE and IFCM
   message headers are 16 bytes long, and the control message header is
   72 bytes long.  The fields in the first sixteen bytes of all message
   headers are the same.

    CONTROL MESSAGES (72 Bytes)
    (zero based offsets below shown in decimal (xx) )
   +-----------------------------+-----------------------------+
   | (00) Version Number         | (01) Header Length (= 72)   |
   +-----------------------------+-----------------------------+
   | (02) Message Length                                       |
   +-----------------------------+-----------------------------+
   | (04) Remote Data Link Correlator                          |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (08) Remote DLC Port ID                                   |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (12) Reserved Field                                       |
   +-----------------------------+-----------------------------+
   | (14) Message Type           | (15) Flow Control Byte      |
   +-----------------------------+-----------------------------+
   | (16) Protocol ID            | (17) Header Number          |
   +-----------------------------+-----------------------------+
   | (18) Reserved                                             |
   +-----------------------------+-----------------------------+
   | (20) Largest Frame Size     | (21) SSP Flags              |
   +-----------------------------+-----------------------------+
   | (22) Circuit Priority       | (23) Message Type (see note)|
   +-----------------------------+-----------------------------+
   | (24) Target MAC Address  (non-canonical format)           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -|
   |                                                           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (30) Origin MAC Address  (non-canonical format)           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -|





Wells & Bartky                                                  [Page 8]
^L
RFC 1795                  Data Link Switching                 April 1995


   |                                                           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |            .                              .               |
   +-----------------------------+-----------------------------+
   | (36) Origin Link SAP        | (37) Target Link SAP        |
   +-----------------------------+-----------------------------+
   | (38) Frame Direction        | (39) Reserved               |
   +-----------------------------+-----------------------------+
   | (40) Reserved                                             |
   +-----------------------------+-----------------------------+
   | (42) DLC Header Length                                    |
   +-----------------------------+-----------------------------+
   | (44) Origin DLC Port ID                                   |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (48) Origin Data Link Correlator                          |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (52) Origin Transport ID                                  |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (56) Target DLC Port ID                                   |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (60) Target Data Link Correlator                          |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (64) Target Transport ID                                  |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (68) Reserved Field                                       |
   +-----------------------------+-----------------------------+
   | (70) Reserved Field                                       |
   +-----------------------------+-----------------------------+
            (Even Byte)                     (Odd Byte)










Wells & Bartky                                                  [Page 9]
^L
RFC 1795                  Data Link Switching                 April 1995


    INFORMATION MESSAGE (16 Bytes)
   +-----------------------------+-----------------------------+
   | (00) Version Number         | (01) Header Length (= 16)   |
   +-----------------------------+-----------------------------+
   | (02) Message Length                                       |
   +-----------------------------+-----------------------------+
   | (04) Remote Data Link Correlator                          |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (08) Remote DLC Port ID                                   |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | (12) Reserved Field                                       |
   +-----------------------------+-----------------------------+
   | (14) Message Type           | (15) Flow Control Byte      |
   +-----------------------------+-----------------------------+
            (Even Byte)                    (Odd Byte)

   The first sixteen bytes of control and information message headers
   contain identical fields.  A brief description of some of the fields
   in an SSP message are shown below (if not defined below, the fields
   and/or their values are described in subsequent sections).

   The Version Number field (offset 0) is set to 0x31 (ASCII '1'),
   indicating a decimal value of 49.  This is used to indicate DLSw
   version 1.

   The Header Length field (offset 1) is 0x48 for control messages,
   indicating a decimal value of 72 bytes, and 0x10 for information and
   Independent Flow Control messages, indicating a decimal value of 16
   bytes.

   The Message Length field (offset 2) defines the number of bytes
   within the data field following the header.

   The Flow Control Byte field (offset 15)  is described in section 8.

   The Header Number field (offset 17) is 0x01, indicating a value of
   one.

   The Circuit Priority field (offset 22) is described in section 4.

   The Frame Direction field (offset 38) is set to 0x01 for frames sent
   from the origin DLSw to the target DLSw, and is set to 0x02 for
   frames sent from the target DLSw to the origin DLSw.




Wells & Bartky                                                 [Page 10]
^L
RFC 1795                  Data Link Switching                 April 1995


   Note:  The Remote Data Link Correlator and Remote DLC Port ID are set
   equal to the Target Data Link Correlator and Target DLC Port ID if
   the Frame Direction field is set to 0x01, and are set equal to the
   Origin Data Link Correlator and Origin DLC Port ID if the Direction
   Field is set to 0x02.

   The Protocol ID field is set to 0x42, indicating a decimal value of
   66.

   The DLC Header Length is set to zero for SNA and is set to 0x23 for
   NetBIOS datagrams, indicating a length of 35 bytes.  This includes
   the Access Control (AC) field, the Frame Control (FC) field,
   Destination MAC Address (DA), the Source MAC Address (SA), the
   Routing Information (RI) field (padded to 18 bytes), the Destination
   link SAP (DSAP), the Source link SAP (SSAP), and the LLC control
   field (UI).

   NOTE:  The values for the Message Type field are defined in section
   3.5. Note that this value is specified in two different fields
   (offset 14 and 23 decimal) of the control message header.  Only the
   first field is to be used when parsing a received SSP message.  The
   second field is to be ignored by new implementations on reception.
   The second field was left in for backwards compatibility with RFC
   1434 implementations and this field may be used in future versions if
   needed.

   The SSP Flags field contains additional information related to the
   SSP message.  The flags are defined as follows (bit 7 being the most
   significant bit and bit 0 the least significant bit of the octet):

   Bit(s)
   76543210    Name    Meaning
   ---------   -----   -------
   x.......    SSPex   1 = explorer message (CANUREACH and ICANREACH)

   Reserved fields are set to zero upon transmission and should be
   ignored upon receipt.

3.2  Address Parameters

   A data link is defined as a logical association between the two end
   stations using Data Link Switching.  It is identified by a Data Link
   ID (14 bytes) consisting of the pair of attachment addresses
   associated with each end system.  Each attachment address is
   represented by the concatenation of the MAC address (6 bytes) and the
   LLC address (1 byte).  Each attachment address is classified as
   either "Target" in the context of the Destination MAC/SAP addresses
   of an explorer frame sent in the first frame used to establish a



Wells & Bartky                                                 [Page 11]
^L
RFC 1795                  Data Link Switching                 April 1995


   circuit, or "Origin" in the context of the Source MAC/SAP addresses.
   All MAC addresses are expressed in non-canonical (Token-Ring) format.

    DATA LINK ID  (14 Bytes @ Control message offset 24 decimal)
   +-----------------------------+-----------------------------+
   | Target MAC Address                                        |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | Origin MAC Address                                        |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | Origin Link SAP             | Target Link SAP             |
   +-----------------------------+-----------------------------+


   An end-to-end circuit is identified by a pair of Circuit ID's.  A
   Circuit ID is a 64 bit number that identifies the DLC circuit within
   a single DLSw.  It consists of a DLC Port ID (4 bytes), and a Data
   Link Correlator (4 bytes).  The Circuit ID must be unique in a single
   DLSw and is assigned locally.  The pair of Circuit ID's along with
   the Data Link IDs,  uniquely identify a single end-to-end circuit.
   Each DLSw must keep a table of these Circuit ID pairs, one for the
   local end of the circuit and the other for the remote end of the
   circuit.  In order to identify which Data Link Switch originated the
   establishment of a circuit, the terms, "Origin" DLSw and "Target"
   DLSw, will be employed in this document.

    CIRCUIT ID   (8 Bytes)
   +-----------------------------+-----------------------------+
   | DLC Port ID                                               |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+
   | Data Link Correlator                                      |
   +- - - - - - - - - - - - - - -+- - - - - - - - - - - - - - -+
   |                                                           |
   +-----------------------------+-----------------------------+

   The Origin Transport ID and the Target Transport ID fields in the
   message header are used to identify the individual TCP/IP port on a
   Data Link Switch.  The values have only local significance.  However,
   each Data Link Switch is required to reflect the values contained in



Wells & Bartky                                                 [Page 12]
^L
RFC 1795                  Data Link Switching                 April 1995


   these two fields, along with the associated values for DLC Port ID
   and the Data Link Correlator, when returning a message to the other
   Data Link Switch.

   The following figure shows the use of the addressing parameters
   during the establishment of an end-to-end connection.  The CANUREACH,
   ICANREACH, and REACH_ACK message types all carry the Data Link ID,
   consisting of the MAC and Link SAP addresses associated with the two
   end stations.  The CANUREACH and ICANREACH messages are qualified by
   the SSPex flag into CANUREACH_ex, ICANREACH_ex (explorer messages)
   and CANUREACH_cs, ICANREACH_cs (circuit start).  The CANUREACH_ex is
   used to find a remote MAC and Link SAP address without establishing
   an SSP circuit.  Upon receipt of a CANUREACH_cs message, the target
   DLSw starts a data link for each port, thereby obtaining a Data Link
   Correlator.  If the target station can be reached, an ICANREACH_cs
   message is returned to the origin DLSw containing the Target Circuit
   ID parameter.  Upon receipt, the origin DLSw starts a data link and
   returns the Origin Circuit ID to the target DLSw within the REACH_ACK
   message.  (Note for a full list of message types, see section 3.5.)

   +------------+                                +------------+
   |Disconnected|                                |Disconnected|
   +------------+   CANUREACH_cs (Data Link ID)  +------------+
       ------------------------------------------------->
         ICANREACH_cs (Data Link ID, Target Circuit ID)
       <------------------------------------------------
     REACH_ACK (Data Link ID, Origin Cir ID, Target Cir ID)
       ------------------------------------------------->
   +------------+                                +------------+
   |Circuit Est.|                                |Circuit Est.|
   +------------+                                +------------+
     XIDFRAME (Data Link ID, Origin Cir ID, Target Cir ID)
       <------------------------------------------------>
      CONTACT (Data Link ID, Origin Cir ID, Target Cir ID)
       ------------------------------------------------->
     CONTACTED (Data Link ID, Origin Cir ID, Target Cir ID)
       <-------------------------------------------------
   +------------+                                +------------+
   | Connected  |                                | Connected  |
   +------------+                                +------------+
        INFOFRAME (Remote Circuit ID = Target Circuit ID)
       ------------------------------------------------->
        INFOFRAME (Remote Circuit ID = Origin Circuit ID)
       <-------------------------------------------------

   During the exchange of the XIDFRAME, CONTACT, and CONTACTED messages,
   the pair of Circuit ID parameters is included in the message format
   along with the DATA LINK ID parameter.  Once the connection has been



Wells & Bartky                                                 [Page 13]
^L
RFC 1795                  Data Link Switching                 April 1995


   established, the INFOFRAME messages are exchanged with the shorter
   header.  This header contains only the Circuit ID associated with the
   remote DLSw.  The Remote Data Link Correlator and the Remote DLC Port
   ID are set equal to the Data Link Correlator and the DLC Port ID that
   are associated with the origin or target Data Link Switch, dependent
   upon the direction of the packet.

3.3  Correlators

   The local use, and contents of the Data Link Correlator, Port ID and
   Transport ID fields in SSP messages is an implementation choice.
   These fields have local significance only.  The values received from
   a partner DLSw must not be interpreted by the DLSw that receives them
   and should be echoed "as is" to a partner DLSw in subsequent
   messages.  All implementations must obey the following rules in this
   section (3.3) on the assignment and fixing of these correlator fields
   for each transport connection or circuit:

   The Transport ID fields are learned from the first SSP message
   exchanged with a DLSw partner (the Capabilities exchange).  This
   field should not be varied by a DLSw after the capabilities exchange
   and must be reflected to the partner DLSw in every SSP control
   message.

   The Target Data Link Correlator, Target Port ID and Target Transport
   ID must remain the same once the Target DLSw has sent the
   ICANREACH_cs for a given circuit.  The Origin DLSw must store the
   values specified in the ICANREACH_cs and use these on all subsequent
   SSP messages for this circuit.

   The Origin DLSw must allow these fields to vary until the
   ICANREACH_cs is received.  Each SSP message issued for a circuit must
   reflect the values specified by the Target DLSw in the last SSP
   message for this circuit received by the Origin DLSw.  Binary zero
   should be used if no such message has yet been received for a given
   circuit (apart from the Target Transport ID which will have been
   learnt as specified above).

   The Origin Data Link Correlator, Origin Port ID and Origin Transport
   ID must remain the same once the Origin DLSw has issued the REACH_ACK
   for a given circuit.  The Target DLSw must store the values specified
   in the REACH_ACK and use these on all subsequent SSP messages for
   this circuit.

   The Target DLSw must allow these fields to vary until the REACH_ACK
   is received.  Each SSP message issued for a circuit must reflect the
   values specified by the Origin DLSw in the last SSP message for this
   circuit received by the Target DLSw.  Binary zero should be used if



Wells & Bartky                                                 [Page 14]
^L
RFC 1795                  Data Link Switching                 April 1995


   no such message has yet been received for a given circuit (apart from
   the Origin Transport ID which will have been learnt as specified
   above).

   For the purposes of correlator exchange, explorer messages form a
   separate circuit.  Both DLSw partners must reflect the last received
   correlator values as specified above.  However correlators learned on
   explorer messages need not be carried over to a subsequent circuit
   setup attempt.  In particular, the Origin DLSw may elect to use the
   same values for the Origin Data Link Correlator and Origin Port ID
   when it issues a CANUREACH_cs after receiving an ICANREACH_ex or
   NETBIOS_NR_ex. However the Target DLSw must not assume that the
   CANUREACH_cs will specify any of the Target Data Link Correlator or
   Target Port ID that were exchanged on the explorer messages.

   Received SSP messages that require a valid Remote Circuit ID but
   cannot be associated with an existing circuit should be rejected with
   a HALT_DL_NOACK message.  This is done to prevent a situation where
   one DLSw partner has a circuit defined while the other partner does
   not. The exception would be a HALT_DL_NOACK message with an invalid
   Remote Circuit ID.  The HALT_DL_NOACK message is typically used in
   error situations where a response is not appropriate.

   The SSP messages requiring a valid Remote Circuit ID are all messages
   except the following: CANUREACH_ex, CANUREACH_cs, ICANREACH_ex,
   ICANREACH_cs, NETBIOS_NQ_cs, NETBIOS_NR_cs, DATAFRAME, NETBIOS_ANQ,
   NETBIOS_ANR, KEEPALIVE and CAP_EXCHANGE.

3.4  Largest Frame Size Field

   The Largest Frame Size (LF Size) field in the SSP Control Header is
   used to carry the LF Size bits across the DLSw connection.  This
   should be used to ensure that the two end-stations always negotiate a
   frame size to be used on a circuit that does not require the Origin
   and Target DLSw partners to re-segment frames.

   This field is valid on CANUREACH_ex, CANUREACH_cs, ICANREACH_ex,
   ICANREACH_cs, NETBIOS_NQ_ex and NETBIOS_NR_ex messages only. The
   contents of this field should be ignored on all other frames.

   Every DLSw forwarding a SSP frame to its DLSw partner must ensure
   that the contents of this frame reflect the minimum capability of the
   route to its local end-station or any limit imposed by the DLSw
   itself.

   The bit-wise definition of this field is as follows (bit 7 is the
   most significant bit, bit 0 is the least significant bit):




Wells & Bartky                                                 [Page 15]
^L
RFC 1795                  Data Link Switching                 April 1995


     7   6   5   4   3   2   1   0
   +-------------------------------+
   | c | r | b | b | b | e | e | e |
   +-------------------------------+

     c   .   .   .   .   .   .   .  LF Size Control flag
                                    (significant on messages
                                    from Origin to Target
                                    DLSw only)

                                    0=fail circuit if route
                                      obtained requires a
                                      smaller LF size
                                    1=don't fail the circuit
                                      but return the LF size
                                      obtained even if it is
                                      smaller

     .   r   .   .   .   .   .   .  Reserved
     .   .   b   .   .   .   .   .  Largest Frame Bit Base
     .   .   .   b   .   .   .   .  Largest Frame Bit Base
     .   .   .   .   b   .   .   .  Largest Frame Bit Base
     .   .   .   .   .   e   .   .  Largest Frame Bit Extended
     .   .   .   .   .   .   e   .  Largest Frame Bit Extended
     .   .   .   .   .   .   .   e  Largest Frame Bit Extended

             <----- LF Bits ----->

   Refer to IEEE 802.1D Standard, Annex C for encoding of Largest Frame
   base and extended bit values.

   The Origin DLSw "Size Control" flag informs a Target DLSw that
   chooses to reply to *_cs messages on the basis of cached information
   that it may safely return a smaller LF Size on the ICANREACH_cs frame
   if it has had to choose an alternative route on which to initialize
   the circuit.  If this bit is set to 1, the Origin DLSw takes
   responsibility for ensuring that the end-stations negotiate a
   suitable frame size for the circuit. If this bit is set to 0, the
   Target DLSw must not reply to the CANUREACH_cs if it cannot obtain a
   route to the Target end station that support an LF Size at least as
   large as that specified in the CANUREACH_cs frame.

3.5  Message Types

   The following table lists the protocol data units that are exchanged
   between Data Link Switches.  All values not listed are reserved for
   potential use in follow-on releases.




Wells & Bartky                                                 [Page 16]
^L
RFC 1795                  Data Link Switching                 April 1995


   Command          Description                       Type   flags/notes
   -------          --------                         ------  -----------
   CANUREACH_ex     Can U Reach Station-explorer      0x03   SSPex
   CANUREACH_cs     Can U Reach Station-circuit start 0x03
   ICANREACH_ex     I Can Reach Station-explorer      0x04   SSPex
   ICANREACH_cs     I Can Reach Station-circuit start 0x04
   REACH_ACK        Reach Acknowledgment              0x05
   DGRMFRAME        Datagram Frame                    0x06   (note 1)
   XIDFRAME         XID Frame                         0x07
   CONTACT          Contact Remote Station            0x08
   CONTACTED        Remote Station Contacted          0x09
   RESTART_DL       Restart Data Link                 0x10
   DL_RESTARTED     Data Link Restarted               0x11
   ENTER_BUSY       Enter Busy                        0x0C   (note 2)
   EXIT_BUSY        Exit Busy                         0x0D   (note 2)
   INFOFRAME        Information (I) Frame             0x0A
   HALT_DL          Halt Data Link                    0x0E
   DL_HALTED        Data Link Halted                  0x0F
   NETBIOS_NQ_ex    NETBIOS Name Query-explorer       0x12   SSPex
   NETBIOS_NQ_cs    NETBIOS Name Query-circuit setup  0x12   (note 3)
   NETBIOS_NR_ex    NETBIOS Name Recognized-explorer  0x13   SSPex
   NETBIOS_NR_cs    NETBIOS Name Recog-circuit setup  0x13   (note 3)
   DATAFRAME        Data Frame                        0x14   (note 1)
   HALT_DL_NOACK    Halt Data Link with no Ack        0x19
   NETBIOS_ANQ      NETBIOS Add Name Query            0x1A
   NETBIOS_ANR      NETBIOS Add Name Response         0x1B
   KEEPALIVE        Transport Keepalive Message       0x1D   (note 4)
   CAP_EXCHANGE     Capabilities Exchange             0x20
   IFCM             Independent Flow Control Message  0x21
   TEST_CIRCUIT_REQ Test Circuit Request              0x7A
   TEST_CIRCUIT_RSP Test Circuit Response             0x7B

   Note 1: Both the DGRMFRAME and DATAFRAME messages are used to carry
   information received by the DLC entity within UI frames.  The
   DGRMFRAME message is addressed according to a pair of Circuit IDs,
   while the DATAFRAME message is addressed according to a Data Link ID,
   being composed of a pair of MAC addresses and a pair of link SAP
   addresses. The latter is employed prior to the establishment of an
   end-to-end circuit when Circuit IDs have yet to be established or
   during circuit restart when Data Links are reset.

   Note 2: These messages are not used for the DLSw Standard but may be
   used by older DLSw implementations.  They are listed here for
   informational purposes.  These messages were added after publication
   of RFC 1434 and were deleted in this standard (adaptive pacing is now
   used instead).





Wells & Bartky                                                 [Page 17]
^L
RFC 1795                  Data Link Switching                 April 1995


   Note 3: These messages are not normally issued by a Standard DLSw,
   which uses the NB_*_ex messages as shown in section 5.4.  However if
   a Standard DLSw attempts to interoperate with older DLSw
   implementations, these messages correspond to the NETBIOS_NQ and
   NETBIOS_NR messages used in RFC1434 both to locate the resource and
   to setup a circuit.  This document does not attempt to provide a
   complete specification of the use of these messages.

   Note 4:  A KEEPALIVE message may be sent by a DLSw to a partner DLSw
   in order to verify the TCP connection (or other future SSP carrying
   protocol) is still functioning.  If received by a DLSw, this message
   is discarded and ignored.  Use of this message is optional.

   For the exchange of NetBIOS control messages, the entire DLC header
   is carried as part of the message unit.  This includes the MAC
   header, with the routing information field padded to 18 bytes, and
   the LLC header. The following message types are affected:
   NETBIOS_NQ, NETBIOS_NR, NETBIOS_ANQ, NETBIOS_ANR, and DATAFRAME when
   being used by NetBIOS systems.  The routing information in the DLC
   header is not used by the remote Data Link Switch upon receiving the
   above five messages.

   Any SSP message types not defined above if received by a DLSw are to
   be ignored (i.e., no error action is to be performed).  A Data Link
   Switch should quietly drop any SSP message with a Message Type that
   is not recognized or not supported.  Receipt of such a message should
   not cause the termination of the transport connection to the message
   sender.

4.  Circuit Priority

   At circuit start time, each circuit end point will provide priority
   information to its circuit partner.  The initiator of the circuit
   will choose which circuit priority will be effective for the life of
   the circuit.  If Priority is not implemented by the Data Link Switch,
   then "Unsupported" priority is used.

4.1  Frame format

   Circuit priority will be valid in the CANUREACH_cs, ICANREACH_cs, and
   REACH_ACK frames only. The relevant header field is shown below.  The
   Circuit Priority value is a byte value at offset 22 in an SSP Control
   Message.








Wells & Bartky                                                 [Page 18]
^L
RFC 1795                  Data Link Switching                 April 1995


   The following describes the format of the Circuit Priority byte.

     7   6   5   4   3   2   1   0
   +-------------------+-----------+
   |   reserved        |    CP     |
   +-------------------+-----------+

   CP: Circuit Priority bits
           000 - Unsupported       (note 1)
           001 - Low Priority
           010 - Medium Priority
           011 - High Priority
           100 - Highest Priority
           101 to 111 are reserved for future use

   Note 1: Unsupported means that the Data Link Switch that originates
   the circuit does not implement priority.  Actions taken on
   Unsupported priority are vendor specific.

4.2  Circuit Startup

   The sender of a CANUREACH_cs is responsible for setting the CP bits
   to reflect the priority it would like to use for the circuit being
   requested.  The mechanism for choosing an appropriate value is
   implementation dependent.  The sender of an ICANREACH_cs frame will
   set the CP bits to reflect the priority it would like to use for the
   circuit being requested, with the mechanism for choosing the
   appropriate value being implementation dependent.  The receiver of
   the ICANREACH_cs will select from the priorities in the CANUREACH_cs
   and ICANREACH_cs frames, and will set the value in the CP field of
   the REACH_ACK frame that follows to the value to be used for this
   circuit.  This priority will be used for the life of the circuit.  A
   CANUREACH_cs or ICANREACH_cs with the circuit priority value set to
   Unsupported (CP=000) indicates that the sender does not support the
   circuit priority function.
















Wells & Bartky                                                 [Page 19]
^L
RFC 1795                  Data Link Switching                 April 1995


   Flow:

      DLSw A               DLSw B

   CANUREACH_cs (CP=011) ----->           Circuit initiator requests
                                          high Priority.

        <--------- ICANREACH_cs (CP=010)  Circuit target requests
                                          medium priority.

   REACH_ACK (CP=010) -------->           Circuit initiator sets
                                          the priority for this
                                          circuit to medium. The
                                          circuit initiator could
                                          choose either high or
                                          medium in this example.

5.  DLSw State Machine

   The following state tables describe the states for a single circuit
   through the Data Link Switch.  State information is kept for each
   connection.  The initial state for a connection is DISCONNECTED.  The
   steady state is either CIRCUIT_ESTABLISHED or CONNECTED.  In the former
   state, an end-to-end circuit has been established allowing the support
   of Type 1 LLC between the end systems.  The latter state exists when an
   end-to-end connection has been established for the support of Type 2 LLC
   services between the end systems.

   For SNA, LLC type 2 connection establishment is via the use of IEEE
   802.2 Test or XID  frames.  SNA devices send these frames to the null
   SAP in order to determine the source route information in support of
   bridging.  Normally SNA devices use SAP 0x04, 0x08, or 0x0C  (most SNA
   LLC2 devices that have a single PU per MAC address use a default of
   0x04).  Typically the SAP would be used to determine if the Test frames
   should be sent to the DLSw code in the router.  If both bridging and
   DLSw are enabled, this allows the product to ensure that SNA frames are
   not both bridged and switched.  Note that although typically SNA uses a
   DSAP and SSAP of 0x04, it allows for other SAPs to be configured and
   supports unequal SAPs.  This allows multiple PUs to share connections
   between two given MAC addresses (each PU to PU session uses one LLC2
   connection).

   For NetBIOS, LLC type 2 connection establishment is via the Name Query
   and Name Recognized frames.  These frames are used for both address
   resolution and source route determination.  NetBIOS devices use SAP
   0xF0.





Wells & Bartky                                                 [Page 20]
^L
RFC 1795                  Data Link Switching                 April 1995


5.1  Data Link Switch States

   The Switch-to-Switch Protocol is formally defined through the state
   machines described in this chapter.  The following table lists the
   thirteen possible states for the main circuit FSM.  A separate state
   machine instance is employed for each end-to-end circuit that is
   maintained by the Data Link Switch.

   State Name            Description
   ----------            -----------
   CIRCUIT_ESTABLISHED   The end-to-end circuit has been
                         established.  At this time LLC Type 1
                         services are available from end-to-end.

   CIRCUIT_PENDING       The target DLSw is awaiting a REACH_ACK
                         response to an ICANREACH_cs message.

   CIRCUIT_RESTART       The DLSw that originated the reset is
                         awaiting the restart of the data link
                         and the DL_RESTARTED response to a
                         RESTART_DL message.

   CIRCUIT_START         The origin DLSw is awaiting a
                         ICANREACH_cs in response to a
                         CANUREACH_cs message.

   CONNECTED             The end-to-end connection has
                         been established thereby allowing
                         LLC Type 2 services from end-to-end
                         in addition to LLC Type 1 services.

   CONNECT_PENDING       The origin DLSw is awaiting the
                         CONTACTED response to a CONTACT
                         message.

   CONTACT_PENDING       The target DLSw is awaiting the
                         DLC_CONTACTED confirmation to a
                         DLC_CONTACT signal (i.e., DLC
                         is waiting for a UA response to
                         an SABME command).

   DISCONNECTED          The initial state with no circuit
                         or connection established, the
                         DLSw is awaiting either a
                         CANUREACH_cs, or an ICANREACH_cs.

   DISCONNECT_PENDING    The DLSw that originated the
                         disconnect is awaiting the DL_HALTED



Wells & Bartky                                                 [Page 21]
^L
RFC 1795                  Data Link Switching                 April 1995


                         response to a HALT_DL message.

   HALT_PENDING          The remote DLSw is awaiting the
                         DLC_DL_HALTED indication following
                         the DLC_HALT_DL request (i.e., DLC
                         is waiting for a UA response to a
                         DISC command), due to receiving a
                         HALT_DL message.

   HALT_PENDING_NOACK    The remote DLSw is awaiting the
                         DLC_DL_HALTED indication following
                         the DLC_HALT_DL request (i.e., DLC
                         is waiting for a UA response to a
                         DISC command), due to receiving a
                         HALT_DL_NOACK message.

   RESTART_PENDING       The remote DLSw is awaiting the
                         DLC_DL_HALTED indication following
                         the DLC_HALT_DL request (i.e., DLC
                         is waiting for a UA response to a
                         DISC command), and the restart of
                         the data link.

   RESOLVE_PENDING       The target DLSw is awaiting
                         the DLC_DL_STARTED indication
                         following the DLC_START_DL request
                         (i.e., DLC is waiting for a Test
                         response as a result of sending a
                         Test command).

   The DISCONNECTED state is the initial state for a new circuit.  One
   end station starts the connection via an XID or SABME command (i.e.,
   DLC_XID or DLC_CONTACTED).  Upon receipt, the Data Link Switches
   exchange a set of CANUREACH_cs, ICANREACH_cs and REACH_ACK messages.
   Upon completion of this three-legged exchange both Data Link Switches
   will be in the CIRCUIT_ESTABLISHED state.  Three pending states also
   exist during this exchange.  The CIRCUIT_START state is entered by
   the origin Data Link Switch after it has sent the CANUREACH_cs
   message.  The RESOLVE_PENDING state is entered by the target Data
   Link Switch awaiting a Test response to a Test Command.  And lastly,
   the CIRCUIT_PENDING state is entered by the target DLSw awaiting the
   REACH_ACK reply to an ICANREACH_cs message.

   The CIRCUIT_ESTABLISHED state allows for the exchange of LLC Type 1
   frames such as the XID exchanges between SNA stations that occurs
   prior to the establishment of a connection.  Also, datagram traffic
   (i.e., UI frames)  may be sent and received between the end stations.
   These exchanges use the XIDFRAME and DGRMFRAME messages sent between



Wells & Bartky                                                 [Page 22]
^L
RFC 1795                  Data Link Switching                 April 1995


   the Data Link Switches.

   In the CIRCUIT_ESTABLISHED state, the receipt of a SABME command
   (i.e., DLC_CONTACTED) causes the origin DLSw to issue a CONTACT
   message, to send an RNR supervisory frame (i.e., DLC_ENTER_BUSY) to
   the origin station, and to enter the CONNECT_PENDING state awaiting a
   CONTACTED message.  The target DLSw, upon the receipt of a CONTACT
   message, will issue a SABME command (i.e., DLC_CONTACT) and enter the
   Contact Pending state.  Once the UA response is received (i.e.,
   DLC_CONTACTED), the target DLSw sends a CONTACTED message and enters
   the CONNECTED state. When received, the origin DLSw enters the
   CONNECTED state and sends an RR supervisory frame (i.e.,
   DLC_EXIT_BUSY).

   The CONNECTED state is the steady state for normal data flow once a
   connection has been established.  Information frames (i.e., INFOFRAME
   messages) are simply sent back and forth between the end points of
   the connection.  This is the path that should be optimized for
   performance.

   The connection is terminated upon the receipt of a DISC frame or
   under some other error condition detected by DLC (i.e., DLC_ERROR).
   Upon receipt of this indication, the DLSw will halt the local data
   link, send a HALT_DL message to the remote DLSw, and enter the
   DISCONNECT_PENDING State.  When the HALT_DL frame is received by the
   other DLSw, the local DLC is halted for this data link, a DL_HALTED
   message is returned, and the DISCONNECTED state is entered.  Receipt
   of this DL_HALTED message causes the other DLSw to also enter the
   DISCONNECTED state.

   The CIRCUIT_RESTART state is entered if one of the Data Link Switches
   receives a SABME command  (i.e., DLC_RESET) after data transfer while
   in the CONNECTED state.  This causes a DM command to be returned to
   the origin station and a RESTART_DL message to be sent to the remote
   Data Link Switch. This causes the remote data link to be halted and
   then restarted.  The remote DLSw will then send a DL_RESTARTED
   message back to the first DLSw.  The receipt of the DL_RESTARTED
   message causes the first DLSw to issue a new CONTACT message,
   assuming that the local DLC has been contacted (i.e., the origin
   station has resent the SABME command).  This is eventually responded
   to by a CONTACTED message. Following this exchange, both Data Link
   Switches will return to the CONNECTED state.  If the local DLC has
   not been contacted, the receipt of a DL_RESTARTED command causes the
   Data Link Switch to enter the CIRCUIT_ESTABLISHED state awaiting the
   receipt of a SABME command (i.e., DLC_CONTACTED signal).

   The HALT_PENDING, HALT_PENDING_NOACK and RESTART_PENDING states
   correspond to the cases when the Data Link Switch is awaiting



Wells & Bartky                                                 [Page 23]
^L
RFC 1795                  Data Link Switching                 April 1995


   responses from the local station on the adjacent LAN (e.g., a UA
   response to a DISC command). Also in the RESTART_PENDING state, the
   Data Link Switch will attempt to restart the data link prior to
   sending a DL_RESTARTED message.  For some implementations, the start
   of a data link involves the exchange of a Test command/response on
   the adjacent LAN (i.e., DLC_START_DL).  For other implementations,
   this additional exchange may not be required.

5.2  State Transition Tables

   This section provides a detailed representation of the Data Link
   Switch, as documented by a single state machine.  Many of the
   transitions are dependent upon local signals between the Data Link
   Switch entity and one of the DLC entities.  These signals and their
   definitions are given in the following tables.

   DLC Events:

   Event Name      Description
   ----------      -----------
   DLC_CONTACTED   Contact Indication:  DLC has received an SABME
                   command or DLC has received a UA response as a
                   result of sending an SABME command.

   DLC_DGRM        Datagram Indication:  DLC has received a UI frame.

   DLC_ERROR       Error condition indicated by DLC:  Such a
                   condition occurs when a DISC command is received
                   or when DLC experiences an unrecoverable error.

   DLC_INFO        Information Indication:  DLC has received an
                   Information (I) frame.

   DLC_DL_HALTED   Data Link Halted Indication:  DLC has
                   received a UA response to a DISC command.

   DLC_DL_STARTED  Data Link Started Indication:  DLC has
                   received a Test response from the null SAP.

   DLC_RESET       Reset Indication:  DLC has received an SABME
                   command during the time a connection is
                   currently active and has responded with DM.

   DLC_RESOLVE_C   Resolve Command Indication:  DLC has received
                   a Test command addressed to the null SAP, or an
                   XID command addressed to the null SAP.





Wells & Bartky                                                 [Page 24]
^L
RFC 1795                  Data Link Switching                 April 1995


   DLC_RESOLVED    Resolve request:  DLC has received a TEST response
                   frame (or equivalent for non-LAN DLCs) but has not
                   reserved the resources required for a circuit yet.

   DLC_XID         XID Indication:  DLC has received an XID command
                   or response to a non-null SAP.

   Other Events:

   Event Name      Description
   ----------      -----------
   XPORT_FAILURE   Failure of the transport connection used by the
                   circuit.

   CS_TIMER_EXP    The CIRCUIT_START timer (started when the circuit
                   went into CIRCUIT_START state) has expired.


   DLC Actions:

   Action Name     Description
   -----------     -----------
   DLC_CONTACT     Contact Station Request:  DLC will send a SABME
                   command or a UA response to an outstanding SABME
                   command.

   DLC_DGRM        Datagram Request:  DLC will send a UI frame.

   DLC_ENTER_BUSY  Enter Link Station Busy:  DLC will send an
                   RNR supervisory frame.

   DLC_EXIT_BUSY   Exit Link Station Busy:  DLC will send an RR
                   supervisory frame.

   DLC_HALT_DL     Halt Data Link Request:  DLC will send a DISC
                   command.

   DLC_INFO        Information Request:  DLC will send an I frame.

   DLC_RESOLVE     Resolve request:  DLC should issue a TEST (or
                   appropriate equivalent for non-LAN DLCs) but need
                   not reserve the resources required for a circuit yet.

   DLC_RESOLVE_R   Resolve Response Request:  DLC will send a
                   Test response or XID response from the null SAP.

   DLC_START_DL    Start Data Link Request:  DLC will send a Test
                   command to the null SAP.



Wells & Bartky                                                 [Page 25]
^L
RFC 1795                  Data Link Switching                 April 1995


   DLC_XID         XID Request:  DLC will send an XID command or an
                   XID response.


   Other Actions:

   Action Name     Description
   ----------      -----------
   START_CS_TIMER  Start the CIRCUIT_START timer.

   DLC_RESOLVE_R and DLC_START_DL actions require the DLC to reserve the
   resources necessary for a link station as they are used only when a
   circuit is about to be started.  The DLC_RESOLVE action is used for
   topology explorer traffic and does not require such resources to be
   reserved, though a DLC implementation may choose not to distinguish
   this from the DLC_START_DL action.  See section 5.4 for details of
   the actions and events for explorer frames.

   The Data Link Switch is described by a state transition table as
   documented in the following sections.  Each of the states is
   described below in terms of the events, actions, and next state for
   each transition. If a particular event is not listed for a given
   state, no action and no state transition should occur for that event.
   Any significant comments concerning the transitions within a given
   state are given immediately following the table representing the
   state.

   A separate state machine instance is maintained by the Data Link
   Switch for each end-to-end circuit.  The number of circuits that may
   be supported by each Data Link Switch is a local implementation
   option.

   The CANUREACH_ex, ICANREACH_ex, NETBIOS_NQ_ex, and NETBIOS_NR_ex are
   SSP messages that are not associated with a particular circuit.  The
   processing of these messages is covered in section 5.4.
















Wells & Bartky                                                 [Page 26]
^L
RFC 1795                  Data Link Switching                 April 1995


5.2.1  DISCONNECTED State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CANUREACH_cs | DLC_START_DL        | RESOLVE_PENDING      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_XID              | If source route     | If CANUREACH_cs was  |
   |                      | bridged frame with  | sent:                |
   |                      | broadcast indicated:|   CIRCUIT_START      |
   |                      |   Send CANUREACH_ex |                      |
   |                      | else:               |                      |
   |                      |   Send CANUREACH_cs |                      |
   |                      |   START_CS_TIMER    |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | If NETBIOS          |                      |
   |                      | NAME_QUERY:         |                      |
   |                      |  Send NETBIOS_NQ_ex |                      |
   |                      | else:               |                      |
   |                      |  Send DATAFRAME     |                      |
   +----------------------+---------------------+----------------------+
   | DLC_CONTACTED        | Send CANUREACH_cs   | CIRCUIT_START        |
   +----------------------+---------------------+----------------------+

   It is assumed that each Data Link Switch will build a set of topology
   tables giving the identity of each Data Link Switch that can reach a
   specific MAC address or a specific NetBIOS name.  This table can be
   built  using the explorer frames, as per the Explorer FSM in section
   5.4.  As a consequence, the amount of search traffic can be kept to a
   minimum.

   Upon receipt of a TEST command, broadcast XID or NetBIOS NAME_QUERY,
   the Data Link Switch checks the topology table for the target MAC/SAP
   or NetBIOS name.  If there is no matching entry in the table, the
   Data Link Switch uses the explorer FSMs in section 5.4 to locate the
   target MAC/SAP or NetBIOS name.

   When the first non-broadcast XID or SABME flows,  the Data Link
   Switch issues a CANUREACH_cs to attempt to start a circuit.  The
   CANUREACH_cs message is sent to only those Data Link Switches that
   are known to be able to reach the given MAC address.  The mechanism
   by which a topology table entry is determined to be out-of-date and
   is deleted from the table is implementation specific.

   The DISCONNECTED state is exited upon the sending of a CANUREACH_cs
   by the origin DLSw or the receipt of a CANUREACH_cs message by a



Wells & Bartky                                                 [Page 27]
^L
RFC 1795                  Data Link Switching                 April 1995


   prospective target Data Link Switch.  In the latter case, the Data
   Link Switch will issue a Test command to the target station (i.e.,
   DLC_START_DL signal is presented to DLC).

5.2.2  RESOLVE_PENDING State

   +-------------------+-----------------------+-----------------------+
   |        Event      |      Action(s)        |      Next State       |
   +-------------------+-----------------------+-----------------------+
   | Receive DATAFRAME | DLC_DGRM              |                       |
   +-------------------+-----------------------+-----------------------+
   | DLC_DL_STARTED    | If LF value of        | If LF value of        |
   |                   | DLC_DL_STARTED        | DLC_DL_STARTED        |
   |                   | is greater than or    | is greater than or    |
   |                   | equal to LF Size of   | equal to LF Size of   |
   |                   | CANUREACH_cs or LF    | CANUREACH_cs or LF    |
   |                   | Size Control bit set: | Size Control bit set: |
   |                   |   Send ICANREACH_cs   |   CIRCUIT_PENDING     |
   |                   | else:                 | else:                 |
   |                   |   Send DLC_HALT_DL    |   HALT_PENDING_NOACK  |
   +-------------------+-----------------------+-----------------------+
   | DLC_ERROR         |                       | DISCONNECTED          |
   +-------------------+-----------------------+-----------------------+
   | DLC_DGRM          | Send DATAFRAME        |                       |
   +-------------------+-----------------------+-----------------------+

   The RESOLVE_PENDING state is entered upon receipt of a CANUREACH_cs
   message by the target DLSw.  A data link is started, causing a Test
   command to be sent by the DLC.

   Several CANUREACH_cs messages can be received in the RESOLVE_PENDING
   state.  The Data Link Switch may update its topology information
   based upon the origin MAC address information in each CANUREACH_cs
   message.

   Upon the receipt of a DLC_DL_STARTED signal in the RESOLVE_PENDING
   state, the Data Link Switch may update its topology table base upon
   the remote MAC address information.  The ICANREACH_cs message must be
   returned to the first partner DLSw from which a CANUREACH_cs was
   received for this circuit, or an implementation may optionally reply
   to all partners from which the CANUREACH_cs was received.

   The RESOLVE_PENDING state is exited once the data link has been
   started (i.e., a DLC_DL_STARTED signal is received as a result of a
   Test response received by the DLC).  The target Data Link Switch then
   enters the CIRCUIT_PENDING state.





Wells & Bartky                                                 [Page 28]
^L
RFC 1795                  Data Link Switching                 April 1995


5.2.3  CIRCUIT_START State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CANUREACH_cs | If origin MAC addr  | If DLC_START_DL      |
   | for circuit in       | in CANUREACH_cs is  | issued:              |
   | opposite direction   | greater than origin |   RESOLVE_PENDING    |
   |                      | MAC addr of circuit:|                      |
   |                      |   DLC_START_DL      |                      |
   |                      | else:               |                      |
   |                      |   no action taken   |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_cs | If LF Size Control  | If LF Size Control   |
   |                      | bit set and LF Size | bit set and LF Size  |
   |                      | is not negotiable:  | is not negotiable:   |
   |                      |   Send HALT_DL_NOACK|   DISCONNECTED       |
   |                      | else:               | else if Connected:   |
   |                      |   Send REACH_ACK,   |   CONNECT_PENDING    |
   |                      |   Send appropriate  | else:                |
   |                      |   SSP message based |   CIRCUIT_ESTABLISHED|
   |                      |   on the event      |                      |
   |                      |   that generated    |                      |
   |                      |   CANUREACH_cs      |                      |
   |                      |   (see Note)        |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DATAFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | CS_TIMER_EXP         |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+

   The CIRCUIT_START state is entered by the origin Data Link Switch
   when a DLC_XID or DLC_CONTACTED signal has been received from the
   DLC.

   The CIRCUIT_START state is exited upon receipt of an ICANREACH_cs
   message.  A REACH_ACK message is returned to the target Data Link
   Switch.  If the CIRCUIT_START state was entered due to a DLC_XID
   signal, an XIDFRAME message containing the XID is sent to the target
   Data Link Switch.  If the CIRCUIT_START state was entered due to a
   DLC_CONTACTED signal, a CONTACT message is sent to the target Data
   Link Switch.





Wells & Bartky                                                 [Page 29]
^L
RFC 1795                  Data Link Switching                 April 1995


5.2.4  CIRCUIT_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CONTACT      | DLC_CONTACT         | CONTACT_PENDING      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | DLC_HALT_DL         | HALT_PENDING         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive REACH_ACK    | If Connected:       | If Connected:        |
   |                      |  Send CONTACT       |  CONNECT_PENDING,    |
   |                      |                     | else:                |
   |                      |                     |  CIRCUIT_ESTABLISHED |
   +----------------------+---------------------+----------------------+
   | Receive XIDFRAME     | DLC_XID             |                      |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_CONTACTED        | If UA is sent in    |                      |
   |                      | response to SABME:  |                      |
   |                      |   DLC_ENTER_BUSY    |                      |
   |                      | else:               |                      |
   |                      |   no action taken   |                      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | DLC_XID              | Drop or hold until  |                      |
   |                      | REACH_ACK received  |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DATAFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The CIRCUIT_PENDING state is entered by the target Data Link Switch
   following the sending of an ICANREACH_cs message.  In this state it
   is awaiting the reception of a REACH_ACK message from the origin Data
   Link Switch.

   If the target Data Link Switch happens to receive a SABME command
   from the target station while in the CIRCUIT_PENDING state (i.e., a
   DLC_CONTACTED signal received from the DLC), the reception of the
   REACH_ACK message causes the target Data Link Switch to enter the
   CONNECT_PENDING state and to send a CONTACT message to the origin



Wells & Bartky                                                 [Page 30]
^L
RFC 1795                  Data Link Switching                 April 1995


   Data Link Switch.

   If no such SABME is received, the receipt of the REACH_ACK causes the
   Data Link Switch to enter CIRCUIT_ESTABLISHED state.

5.2.5  CONNECT_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CONTACTED    | If UA was sent in   | CONNECTED            |
   |                      | response to SABME:  |                      |
   |                      |   DLC_EXIT_BUSY     |                      |
   |                      | else:               |                      |
   |                      |   DLC_CONTACT       |                      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | DLC_HALT_DL         | HALT_PENDING         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_cs | Send HALT_DL_NOACK  |                      |
   +----------------------+---------------------+----------------------+
   | DLC_RESET            | Send RESTART_DL     | CIRCUIT_RESTART      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The CONNECT_PENDING state is entered when a DLC_CONTACTED signal has
   been received from the DLC (i.e., a SABME command has been received).
   A CONTACT message it then  issued.  The state is exited upon the
   receipt of a CONTACTED message.  If a DLC_RESET signal is received,
   the local data link is restarted and a RESTART_DL message is sent to
   the remote DLSw.

   An ICANREACH_cs received after the transition to CONNECT_PENDING
   state indicates that more than one CANUREACH_cs was sent at circuit
   establishment time and the target station was found by more than one
   Data Link Switch partner.  A HALT_DL_NOACK is sent to halt the
   circuit started by the Data Link Switch partner that originated each
   such ICANREACH_cs.



Wells & Bartky                                                 [Page 31]
^L
RFC 1795                  Data Link Switching                 April 1995


   Note:  Some implementations will also send a Test command in order to
   restart the data link to the station that sent the SABME command
   (i.e., a DLC_START_DL will be issued).

5.2.6  CIRCUIT_ESTABLISHED State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CONTACT      | DLC_CONTACT         | CONTACT_PENDING      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | DLC_HALT_DL         | HALT_PENDING         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive XIDFRAME     | DLC_XID             |                      |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_cs | Send HALT_DL_NOACK  |                      |
   +----------------------+---------------------+----------------------+
   | DLC_CONTACTED        | Send CONTACT        | CONNECT_PENDING      |
   |                      | If UA is sent in    |                      |
   |                      | response to SABME:  |                      |
   |                      |   DLC_ENTER_BUSY    |                      |
   |                      | else:               |                      |
   |                      |   no action taken   |                      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | DLC_XID              | Send XIDFRAME       |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The CIRCUIT_ESTABLISHED state is entered by the origin Data Link
   Switch from the CIRCUIT_START state, and by the target Data Link
   Switch from the CIRCUIT_PENDING state.  The state is exited when a
   connection is started (i.e., DLC receives a SABME command) or CONTACT
   is received. The next state is CONTACT_PENDING or CONNECT_PENDING.

   An ICANREACH_cs received after the transition to CIRCUIT_ESTABLISHED
   state indicates that more than one CANUREACH_cs was sent at circuit
   establishment time and the target station was found by more than one



Wells & Bartky                                                 [Page 32]
^L
RFC 1795                  Data Link Switching                 April 1995


   Data Link Switch partner.  A HALT_DL_NOACK is sent to halt the
   circuit started by the Data Link Switch partner that originated each
   such ICANREACH_cs.

5.2.7  CONTACT_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | DLC_HALT_DL         | HALT_PENDING         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive RESTART_DL   | DLC_HALT_DL         | RESTART_PENDING      |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_CONTACTED        | Send CONTACTED      | CONNECTED            |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The CONTACT_PENDING state is entered upon the receipt of a CONTACT
   message, which causes the Data Link Switch to issue a DLC_CONTACT
   signal to the DLC (i.e., DLC sends a SABME command).  This state is
   then exited upon the receipt of a DLC_CONTACTED signal from the DLC
   (i.e., a UA response received).

   If a RESTART_DL message is received, indicating that the remote Data
   Link Switch has received a DLC_RESET signal, the local Data Link
   Switch sends a DISC command frame on the adjacent LAN (i.e.,
   DLC_HALT_DL signal) and enter the RESTART_PENDING state.

   An ICANREACH_cs received after the transition to CONTACT_PENDING
   state indicates that more than one CANUREACH_cs was sent at circuit
   establishment time and the target station was found by more than one
   Data Link Switch partner.  A HALT_DL_NOACK is sent to halt the data
   link started by the Data Link Switch partner that originated this
   ICANREACH_cs.






Wells & Bartky                                                 [Page 33]
^L
RFC 1795                  Data Link Switching                 April 1995


5.2.8  CONNECTED State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | DLC_HALT_DL         | HALT_PENDING         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive RESTART_DL   | DLC_HALT_DL         | RESTART_PENDING      |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive INFOFRAME    | DLC_INFO            |                      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | Receive XIDFRAME     | If non-activation   |                      |
   |                      | XID3:               |                      |
   |                      |   DLC_XID           |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_cs | Send HALT_DL_NOACK  |                      |
   +----------------------+---------------------+----------------------+
   | Receive ENTER_BUSY   | DLC_ENTER_BUSY      |                      |
   +----------------------+---------------------+----------------------+
   | Receive EXIT_BUSY    | DLC_EXIT_BUSY       |                      |
   +----------------------+---------------------+----------------------+
   | Rec TEST_CIRCUIT_REQ | Snd TEST_CIRCUIT_RSP|                      |
   +----------------------+---------------------+----------------------+
   | DLC_RESET            | Send RESTART_DL     | CIRCUIT_RESTART      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | DLC_INFO             | Send INFOFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | DLC_XID              | If non-activation   |                      |
   |                      | XID3:               |                      |
   |                      |   Send XIDFRAME     |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The CONNECTED state is entered from the CONNECT_PENDING state upon
   the receipt of a CONTACTED message or from the CONTACT_PENDING state
   upon the receipt of a DLC_CONTACTED signal.




Wells & Bartky                                                 [Page 34]
^L
RFC 1795                  Data Link Switching                 April 1995


   The CONNECTED state is exited usually under one of two conditions: a
   DLC_ERROR signal received from the DLC (e.g., a DISC command received
   by the local DLC), or a HALT_DL message received from the other Data
   Link Switch (e.g., a DISC command received by the remote DLC).

   A SABME command (i.e., a DLC_RESET signal) received by either Data
   Link Switch will also cause the two Data Link Switches to leave the
   CONNECTED state and attempt to restart the circuit.  Following the
   receipt of a SABME, the local Data Link Switch sends a RESTART_DL
   message to the other Data Link Switch and enters the CIRCUIT_RESTART
   state.  Upon the receipt of the RESTART_DL message, the remote Data
   Link Switch sends a DISC command (i.e., DLC_HALT_DL signal) and
   enters the RESTART_PENDING state.

   An ICANREACH_cs received after the transition to CONNECTED state
   indicates that more than one CANUREACH_cs was sent at circuit
   establishment time and the target station was found by more than one
   Data Link Switch partner.  A HALT_DL_NOACK is sent to halt the
   circuit started by the Data Link Switch partner that originated each
   such ICANREACH_cs.

   Note:  Some implementations will also send a Test command in order to
   restart the data link to the station that sent the SABME command
   (i.e., a DLC_START_DL will be issued).

5.2.9  CIRCUIT_RESTART State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive DL_RESTARTED | If Connected:       | If Connected:        |
   |                      |  Send CONTACT       |  CONNECT_PENDING,    |
   |                      |                     | else:                |
   |                      |                     |  CIRCUIT_ESTABLISHED |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK| DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+






Wells & Bartky                                                 [Page 35]
^L
RFC 1795                  Data Link Switching                 April 1995


   The CIRCUIT_RESTART state is entered if a DLC_RESET signal is
   received from the local DLC.  This was caused by the receipt of a
   SABME command while a connection was currently active.  A DM response
   will be issued to the SABME command and the Data Link Switch will
   attempt to restart the end-to-end circuit.

   The CIRCUIT_RESTART state is exited through one of two transitions.
   The next state depends upon the time the local DLC has reached the
   contacted state (i.e., a DLC_CONTACTED signal is presented) relative
   to the receipt of the DL_RESTARTED message.  This signal is caused by
   the origin station resending the SABME command that initially caused
   the Data Link Switch to enter the CIRCUIT_RESTART state.  The two
   cases are as follows:

      1) DL_RESTARTED message received before the DLC_CONTACTED signal-
         In this case, the CIRCUIT_ESTABLISHED state is entered.

      2) DL_RESTARTED message received after the DLC_CONTACTED signal-
         In this case, the CONNECT_PENDING state is entered.

5.2.10  DISCONNECT_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive DL_HALTED    |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL      | Send DL_HALTED      |                      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK|                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DATAFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+

   The DISCONNECT_PENDING state is entered when a DLC_ERROR signal is
   received from the local DLC.  Upon receipt of this signal, a HALT_DL
   message is sent.  Once an DL_HALTED message is received, the state is
   exited, and the Data Link Switch enters the DISCONNECTED state.









Wells & Bartky                                                 [Page 36]
^L
RFC 1795                  Data Link Switching                 April 1995


5.2.11  RESTART_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK|                     | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive DGRMFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DL_HALTED        | Send DL_RESTARTED   | CIRCUIT_ESTABLISHED  |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send HALT_DL        | DISCONNECT_PENDING   |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DGRMFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        | DLC_HALT_DL         | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+

   The RESTART_PENDING state is entered upon the receipt of a RESTART_DL
   message from the remote DLSw while the local Data Link Switch is in
   either the CONTACT_PENDING state or the CONNECTED state, which causes
   the local DLSw to issue a DISC command to the DLC.  Upon the receipt
   of the UA response (DLC_DL_HALTED), the data link is restarted, a
   DL_RESTARTED message is returned to the remote DLSw, and the
   CIRCUIT_ESTABLISHED state is entered.

   Note:  Some implementations will send a Test command in order to
   restart the data link to the target station (i.e., a DLC_START_DL
   will be issued) prior to sending the DL_RESTARTED message.

5.2.12  HALT_PENDING State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive HALT_DL_NOACK|                     | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DL_HALTED        | Send DL_HALTED      | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            | Send DL_HALTED      | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DATAFRAME      |                      |
   +----------------------+---------------------+----------------------+
   | XPORT_FAILURE        |                     | HALT_PENDING_NOACK   |
   +----------------------+---------------------+----------------------+




Wells & Bartky                                                 [Page 37]
^L
RFC 1795                  Data Link Switching                 April 1995


   The HALT_PENDING state is entered upon the receipt of a HALT_DL
   message. This causes the local DLC to issue a DISC command.  Upon the
   receipt of the UA response (DLC_DL_HALTED), a DL_HALTED message is
   returned to the remote DLSw and the DISCONNECTED state is entered.

5.2.13  HALT_PENDING_NOACK State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive DATAFRAME    | DLC_DGRM            |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DL_HALTED        |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | DLC_ERROR            |                     | DISCONNECTED         |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM             | Send DATAFRAME      |                      |
   +----------------------+---------------------+----------------------+

   The HALT_PENDING_NOACK state is entered upon the receipt of a
   HALT_DL_NOACK message.  This causes the local DLC to issue a DISC
   command.  Upon the receipt of the UA response (DLC_DL_HALTED), the
   DISCONNECTED state is entered.

5.3  NetBIOS Datagrams

   The NetBIOS protocols use a number of UI frames for directory
   services and the transmission of datagrams.  Most of these frames are
   directed to a group MAC address (GA) with the routing information
   field indicating spanning tree explorer (STE) (a.k.a. Single Route
   Broadcast).  The NB_Add_Name_Response and NB_Name_Recognized frames
   are directed to a specific MAC address with the routing information
   field indicating an all routes explorer frame (ARE) (a.k.a. All
   Routes Broadcast)  The NB_Status_Response frame, is directed to a
   specific MAC address with the routing information field indicating a
   specifically routed frame (SRF). The handling of these frames is
   summarized in the following table.














Wells & Bartky                                                 [Page 38]
^L
RFC 1795                  Data Link Switching                 April 1995


   +---------------------------+------------------+--------------------+
   |          Event            |     Action(s)    |      Comment       |
   +---------------------------+------------------+--------------------+
   | DLC_DGRM for NETBIOS      | Send NETBIOS_ANQ | Transmitted to all |
   |  group address:           |                  |   remote DLSw      |
   |   NB_Add_Name_Query       |                  |                    |
   +---------------------------+------------------+--------------------+
   | DLC_DGRM for a specific   | Send NETBIOS_ANR | Transmitted to     |
   |  address:                 |                  |   specific DLSw    |
   |   NB_Add_Name_Response    |                  |                    |
   +---------------------------+------------------+--------------------+
   | DLC_DGRM for a specific   | Send DATAFRAME   | Transmitted to all |
   |  address:                 |                  |   remote DLSw      |
   |   NB_Status_Response      |                  |                    |
   +---------------------------+------------------+--------------------+
   | DLC_DGRM for NETBIOS      | Send DATAFRAME   | Transmitted to all |
   |  group address:           |                  |   remote DLSw      |
   |   NB_Name_in_Conflict     |                  |                    |
   |   NB_Add_Group_Name_Query |                  |                    |
   |   NB_Datagram,            |                  |                    |
   |   NB_Datagram_Broadcast   |                  |                    |
   |   NB_Status_Query         |                  |                    |
   |   NB_Terminate_Trace      |                  |                    |
   +---------------------------+------------------+--------------------+

   The above actions do not apply in the following states:
   CIRCUIT_ESTABLISHED, CONTACT_PENDING, CONNECT_PENDING, CONNECTED, and
   CIRCUIT_PENDING.  The handling of the remaining two UI frames used by
   NetBIOS systems, NB_Name_Query and NB_Name_Recognized, are documented
   as part of the DLSw state machine in the previous section (i.e.,
   DISCONNECTED and RESOLVE_PENDING states).  Furthermore, the handling
   of NetBIOS datagrams (i.e., NB_Datagram) sent to a specific MAC
   address is also governed by the DLSw state machine.

   Note:  Some implementations also issue Test frames during the
   exchange of the NetBIOS, NB_Name_Query and NB_Name_Recognized.  This
   exchange of protocol data units occurs during the start of a data
   link and is used to determine the routing information.  Most other
   implementations of NetBIOS will use the
   NB_Name_Query/NB_Name_Recognized exchange to determine routes in
   conjunction with resolving the NetBIOS names. These differences are
   not reflected in the SSP protocols.









Wells & Bartky                                                 [Page 39]
^L
RFC 1795                  Data Link Switching                 April 1995


   The handling of the NetBIOS specific SSP messages is given in the
   following table.

   +---------------+-------------------------+-------------------------+
   |     Event     |        Action(s)        |         Comment         |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_ANQ   | DLC_DGRM:               | Routed STE              |
   |               |    NB_Add_Name_Query    | (NETBIOS Group Address) |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_ANR   | DLC_DGRM:               | Routed ARE              |
   |               |    NB_Add_Name_Response | (Specific MAC Address)  |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_NQ_ex | DLC_DGRM:               | Routed STE              |
   |               |    NB_Name_Query        | (NETBIOS Group Address) |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_NQ_cs | DLC_DGRM:               | Routed STE              |
   |               |    NB_Name_Query        | (NETBIOS Group Address) |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_NR_ex | DLC_DGRM:               | Routed ARE              |
   |               |    NB_Name_Recognized   | (Specific MAC Address)  |
   +---------------+-------------------------+-------------------------+
   | NETBIOS_NR_cs | DLC_DGRM:               | Routed ARE              |
   |               |    NB_Name_Recognized   | (Specific MAC Address)  |
   +---------------+-------------------------+-------------------------+
   | DATAFRAME     | DLC_DGRM                | If NB_Status_Response:  |
   |               |                         |  Routed ARE             |
   |               |                         |  (Specific MAC Address) |
   |               |                         | Else:                   |
   |               |                         |  Routed STE             |
   |               |                         |  (NETBIOS Group Address)|
   +---------------+-------------------------+-------------------------+

   The above actions apply to all DLSw states.  The handling of NetBIOS
   datagrams sent within DGRMFRAME messages is governed by the DLSw
   state machine.  The DGRMFRAME message type is employed instead of the
   DATAFRAME message type once the end-to-end circuit has been
   established. At that time, the message is addressed according to the
   pair of Circuit IDs in the message header instead of relying upon the
   MAC address information in the token ring header.

5.4  Explorer Traffic

   The CANUREACH_ex, ICANREACH_ex, NETBIOS_NQ_ex, and NETBIOS_NR_ex SSP
   messages explore the topology of the DLSw cloud and the networks
   attached to it.  These explorer frames are used to determine the DLSw
   partners through which a MAC or NetBIOS name can be accessed.  This
   information may optionally be cached to reduce explorer traffic in
   the DLSw cloud.



Wells & Bartky                                                 [Page 40]
^L
RFC 1795                  Data Link Switching                 April 1995


   If a DLSw is aware from cached information that a given MAC address
   or NetBIOS name is accessible through a given partner DLSw, it should
   direct all circuit setup attempts to that partner.  If the circuit
   setup fails, or no such data is available in the MAC or name cache
   database, the DLSw may fallback to issuing the setup attempt to all
   DLSw partners on the assumption that the cached data is now out of
   date.  The mechanism for determining when to use such a fallback is
   implementation defined.

   DLSw implementations may also use a local MAC cache to enable
   responses to CANUREACH_ex requests to be issued without the need for
   TEST frame exchange (or equivalent) until the CANUREACH_cs is
   received.  Again, the fallback mechanism for determining when such
   local cache data is out-of-date is implementation defined.

   The use of either cache is an optional function in DLSw.  An
   implementation may choose to always issue explorer frames or to use
   either or both types of cache.

   The following sections describe the FSMs used for explorer frames.
   The DLC events and actions are a subset of those described in section
   5.2 for the main circuit FSM.

5.4.1  CANUREACH/ICANREACH Explorer FSM

   The FSM described below is used to handle explorer frames routed by
   MAC address.  There is one instance of this FSM for each Data Link ID
   (Target and Origin MAC/SAP pair) for which explorer traffic is
   flowing. The states in this FSM are as follows.

   State Name            Description
   ----------            -----------
   RESET                 The initial state.

   SENT_EX               Local DLSw has issued an explorer message

   RECEIVED_EX           Local DLSw has received an explorer message














Wells & Bartky                                                 [Page 41]
^L
RFC 1795                  Data Link Switching                 April 1995


5.4.1.1  RESET State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CANUREACH_ex | If replying from    | If DLC_RESOLVE sent, |
   |                      | cache, send         |   RECEIVED_EX        |
   |                      | ICANREACH_ex        |                      |
   |                      | else if allowed to  |                      |
   |                      | test availability,  |                      |
   |                      | issue DLC_RESOLVE.  |                      |
   |                      | Optionally update   |                      |
   |                      | cache.              |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_ex | Optionally update   | RESET                |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_RESOLVE_C        | Send CANUREACH_ex   | SENT_EX              |
   +----------------------+---------------------+----------------------+

   RESET is the initial state for the CANUREACH/ICANREACH explorer FSM.
   This state is exited when a DLC_RESOLVE_C request is received from
   the DLC or a CANUREACH_ex is received from a remote DLSw.

   A DLSw implementation may optionally reply from to CANUREACH_ex
   messages on the basis of cached topology information, in which case
   the DLC_RESOLVE exchange (i.e., TEST) is not required.  If cache is
   not used, or no match is found, and the DLC permits the use of TEST,
   DLC_RESOLVE is issued to locate the target MAC and the state changes
   to RECEIVED_EX. If no cache entry is available and TEST is not
   allowed by the DLC, a received CANUREACH_ex frame is ignored.

5.4.1.2  SENT_EX State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_ex | DLC_RESOLVE_R       | RESET                |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_RESOLVE_C        |                     | SENT_EX              |
   +----------------------+---------------------+----------------------+

   SENT_EX is entered when the DLSw has issued a CANUREACH_ex message to
   locate a MAC address.  This state is exited when a remote DLSw
   returns a matching ICANREACH_ex, or after an implementation defined
   timeout. DLC_RESOLVE events received in this state correspond to TEST



Wells & Bartky                                                 [Page 42]
^L
RFC 1795                  Data Link Switching                 April 1995


   retries by the origin DLC station and are absorbed.

   An implementation may choose whether to handle explorer frame
   crossover either by using entirely separate FSM instances and simply
   allowing both ends to issue TEST frames, or by detecting a reverse
   CANUREACH_ex frame here and issuing an ICANREACH_ex message and
   DLC_RESOLVE_R action.

5.4.1.3  RECEIVED_EX State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive CANUREACH_ex | Optionally update   | RECEIVED_EX          |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | Receive ICANREACH_ex |                     | RECEIVED_EX          |
   +----------------------+---------------------+----------------------+
   | DLC_RESOLVED         | Send ICANREACH_ex   | RESET                |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+

   RECEIVED_EX is entered when the DLSw has received a CANUREACH_ex from
   a remote DLSw and has issued a DLC_RESOLVE to locate the MAC address.
   This state is exited when the DLC_RESOLVED response is received, or
   after an implementation defined timeout.

   If the target MAC is located, the DLSw must reply to the first
   received CANUREACH_ex that caused the move to this state.  If
   additional CANUREACH_ex messages are received in this state from
   other remote DLSw partners, the DLSw may optionally reply to these
   messages too but it is not required to do so.

   An implementation may choose whether to handle explorer frame
   crossover either by using entirely separate FSM instances and simply
   allowing both ends to issue TEST frames, or by detecting such a
   reverse DLC_RESOLVE_C event here and issuing an ICANREACH_ex message
   and DLC_RESOLVE_R action.












Wells & Bartky                                                 [Page 43]
^L
RFC 1795                  Data Link Switching                 April 1995


5.4.2  NETBIOS_NQ/NR Explorer FSM

   The FSM described below is used to handle explorer frames routed by
   NetBIOS names  There is one instance of this FSM for each unique
   combination of Source Name, Destination Name, Data 2 field and
   Response Correlator.

   State Name            Description
   ----------            -----------
   RESET                 The initial state.

   SENT_EX               Local DLSw has issued an explorer
                         message

   RECEIVED_EX           Local DLSw has received an explorer
                         message

   SENT_REC_EX           An explorer frame has been both sent
                         and received for the same (potential)
                         NetBIOS circuit.

5.4.2.1  RESET State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NQ_ex| DLC_DGRM(NAME_QUERY)| RECEIVED_EX          |
   |                      | Optionally update   |                      |
   |                      | cache.              |                      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NR_ex| Optionally update   | RESET                |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_QUERY)| Send NETBIOS_NQ_ex  | SENT_EX              |
   +----------------------+---------------------+----------------------+

   The RESET state is the initial state for the NETBIOS_NQ/NR explorer
   FSM. It is exited when the DLC receives either a NETBIOS_NQ_ex or a
   DLC_DGRM containing a NetBIOS NAME_QUERY frame.  If a NETBIOS_NQ_ex
   message is received, the NAME_QUERY is propagated to the DLC and this
   FSM moves to state RECEIVED_EX.  If a NetBIOS NAME_QUERY frame is
   received, the NETBIOS_NQ_ex is propagated either to the appropriate
   DLSw partners (see below), and this FSM moves to state SENT_EX.

   Unlike SNA traffic where the CANUREACH_ex/ICANREACH_ex exchange can
   be omitted if the MAC location is already cached,
   NETBIOS_NQ_ex/NETBIOS_NR_ex frames must always be issued during
   NetBIOS session setup in order that the NetBIOS session numbers are



Wells & Bartky                                                 [Page 44]
^L
RFC 1795                  Data Link Switching                 April 1995


   exchanged correctly between the DLC end stations.  If the location of
   a NetBIOS name is known from cached data, the NETBIOS_NQ_ex need only
   be issued to the cached DLSw partners.  Otherwise the NETBIOS_NQ_ex
   should be issued to all partners that support NetBIOS.

5.4.2.2  SENT_EX State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NQ_ex| DLC_DGRM(NAME_QUERY)| SENT_REC_EX          |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NR_ex| DLC_DGRM(NAME_RECOG)| RESET                |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_QUERY)| Send NETBIOS_NQ_ex  | SENT_EX              |
   | (different local     | Optionally update   |                      |
   |  session number than | cache               |                      |
   |  existing searches)  |                     |                      |
   +----------------------+---------------------+----------------------+

   SENT_EX is entered when the local DLSw issues a NETBIOS_NQ_ex to its
   remote DLSw partners.  This state is exited when a NETBIOS_NR_ex is
   received from a remote DLSw, or if a matching NETBIOS_NQ_ex is
   received from a remote DLSw (i.e., a NETBIOS_NQ_ex crossover case).
   If the local NetBIOS end station issues a NAME_QUERY with a different
   session number from any previous NAME_QUERY for this search, the
   NAME_QUERY is propagated to the DLSw partners to ensure that the
   exchange of NetBIOS session numbers is handled correctly.



















Wells & Bartky                                                 [Page 45]
^L
RFC 1795                  Data Link Switching                 April 1995


5.4.2.3  RECEIVED_EX State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NQ_ex| DLC_DGRM(NAME_QUERY)| RECEIVED_EX          |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NR_ex|                     | RECEIVED_EX          |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_QUERY)| Send NETBIOS_NQ_ex  | SENT_REC_EX          |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_RECOG)| Send NETBIOS_NR_ex  | RESET                |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+

   RECEIVED_EX is entered when the local DLSw receives a NETBIOS_NQ_ex
   message from a remote DLSw.  This state is exited when a
   NAME_RECOGNIZED NetBIOS frame is received from the DLC, completing
   the query, or when a matching NAME_QUERY is received from DLC (i.e.,
   NAME_QUERY crossover).

5.4.2.4  SENT_REC_EX State

   +----------------------+---------------------+----------------------+
   |        Event         |      Action(s)      |      Next State      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NQ_ex| DLC_DGRM(NAME_QUERY)| SENT_REC_EX          |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | Receive NETBIOS_NR_ex| DLC_DGRM(NAME_RECOG)| RECEIVED_EX          |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_QUERY)| Send NETBIOS_NQ_ex  | SENT_REC_EX          |
   | (different local     | Optionally update   |                      |
   |  session number than | cache               |                      |
   |  existing searches)  |                     |                      |
   +----------------------+---------------------+----------------------+
   | DLC_DGRM (NAME_RECOG)| Send NETBIOS_NR_ex  | SENT_EX              |
   |                      | Optionally update   |                      |
   |                      | cache               |                      |
   +----------------------+---------------------+----------------------+



Wells & Bartky                                                 [Page 46]
^L
RFC 1795                  Data Link Switching                 April 1995


   This state is required if an implementation wishes to manage NQ/NR
   crossover cases from a single FSM instance by detecting 'opposite'
   NAME_QUERY attempts between the same two NetBIOS names.  If separate
   FSM instances are used instead, this state is not required and the
   transitions to it from other states can be removed.

   SENT_RCV_EX is exited when the NAME_QUERY search in either direction
   is resolved.  If the local NetBIOS end station issues a NAME_QUERY
   with a different session number from any previous NAME_QUERY it has
   issued for this search, the NAME_QUERY is propagated to the DLSw
   partners to ensure that the exchange of NetBIOS session numbers is
   correctly handled.

5.4.2.5  NetBIOS Session Numbers

   NetBIOS NAME_QUERY and NAME_RECOGNIZED frames exchange NetBIOS session
   numbers between the end stations.  For correct NetBIOS operation over
   DLSw, it is important that all SSP NETBIOS_NQ_ex frames received by a
   DLSw cause NetBIOS NAME_QUERY frames to flow on the LAN with the new
   session number from the NETBIOS_NQ_ex.  These frames cannot be replied
   to from a cache of locally available NetBIOS names in the same way that
   MAC addresses and CANUREACH_ex messages can be handled.

   Also, NAME_QUERY messages are normally retried several times on the LAN.
   The generation and absorption of such frames is outside the scope of the
   FSM defined above.

6.  Protocol Flow Diagrams

   The Switch-to-Switch Protocol is used to setup and take down circuits
   between a pair of Data Link Switches.  Once a circuit is established,
   the end stations on the local networks can employ LLC Type 1
   (connectionless UI frames) protocols end-to-end.  In addition, the end
   systems can establish an end-to-end connection for support of LLC Type 2
   (connection oriented I frames) protocols (Type 2 I frames go end-to-end,
   supervisory frames are handled locally).

   The term, Data Link, is used in this document to refer to both a
   "logical data link" when supporting Type 1 LLC services, and a "data
   link connection" when supporting Type 2 LLC services.  In both cases,
   the Data Link is identified by the Data Link ID defined in section 3.2.

   NOTE:  THIS SECTION CONTAINS EXAMPLES ONLY.  IT CANNOT AND DOES NOT SHOW
   ALL POSSIBLE VARIATIONS AND OPTIONS ON PROTOCOL FLOWS FOR SNA/SDLC, SSP,
   AND LLC PROTOCOLS.






Wells & Bartky                                                 [Page 47]
^L
RFC 1795                  Data Link Switching                 April 1995


6.1  Connect Protocols

   The two basic startup flows from a pure FSM perspective are shown below.
   The first flow is a startup involving XIDs and the second is one without
   XIDs.

Flow #1 - DLSw Startup With XIDs
 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                    disconnected

              DLC_RESOLVE_C   CANUREACH_ex
              ----------->    ----------->
              DLC_RESOLVE_R     ICANREACH_ex
               <-----------     <-----------

              DLC_XID         CANUREACH_cs    DLC_START_DL
              ----------->    ----------->    ----------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED
                                <-----------    <-----------
          circuit_established                 circuit_pending
                              REACH_ACK
                              ----------->   circuit_established

                              XIDFRAME        DLC_XID
                              ----------->    ----------->

                     DLC_XID        XIDFRAME         DLC_XID
                <-----------    <-----------    <-----------
              DLC_XID         XIDFRAME        DLC_XID
              ----------->    ----------->    ----------->

                 DLC_XIDs       XIDFRAMEs        DLC_XIDs
              <------------>  <------------>  <------------>

              DLC_CONTACTED   CONTACT         DLC_CONTACT
              ----------->    ----------->    ----------->
              connect_pending                 contact_pending





Wells & Bartky                                                 [Page 48]
^L
RFC 1795                  Data Link Switching                 April 1995


                 DLC_CONTACT       CONTACTED    DLC_CONTACTED
                <-----------    <-----------    <-----------
                 connected                       connected

                DLC_INFOs        IFRAMEs        DLC_INFOs
              <------------>  <------------>  <------------>

   Mapping LAN events to the DLC events and actions on Flow #1 produces
   the following flows shown below:

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                    disconnected

TEST_cmd      DLC_RESOLVE_C    CANUREACH_ex               TEST_cmd
----------->  ----------->     ----------->               ---------->
   TEST_rsp   DLC_RESOLVE_R     ICANREACH_ex                 TEST_rsp
 <---------    <-----------   <-----------             <-----------
null XID      DLC_XID          CANUREACH_cs    DLC_START_DL
----------->  ----------->     ----------->    ----------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED
                                <-----------    <-------------
           circuit_established                circuit_pending
                              REACH_ACK
                              ----------->  circuit_established

                              XIDFRAME         DLC_XID       null XID
                              ----------->     --------->    -------->
        XID        DLC_XID        XIDFRAME         DLC_XID          XID
  <--------   <-----------    <-----------    <-----------    <--------
    XIDs         DLC_XIDs      XIDFRAMEs        DLC_XIDs         XIDs
<---------->  <---------->  <------------>  <------------>  <--------->
SABME         DLC_CONTACTED   CONTACT         DLC_CONTACT     SABME
----------->  ----------->    ----------->    ----------->    -------->
              connect_pending                 contact_pending

          UA     DLC_CONTACT     CONTACTED    DLC_CONTACTED          UA
  <---------   <-----------   <-----------    <-----------    <--------
                  connected                        connected




Wells & Bartky                                                 [Page 49]
^L
RFC 1795                  Data Link Switching                 April 1995


  IFRAMEs       DLC_INFOs        IFRAMEs        DLC_INFOs       IFRAMEs
<---------->  <----------->  <------------>  <------------>  <-------->

Those implementations that prefer to respond to the SABME immediately
could use the same events to do that:

SABME         DLC_CONTACTED   CONTACT         DLC_CONTACT     SABME
----------->  ----------->    ----------->    ----------->    -------->
          UA  connect_pending                 contact_pending
  <---------
RR
----------->
         RNR
  <---------

          RR    DLC_CONTACT       CONTACTED    DLC_CONTACTED          UA
  <---------   <-----------    <-----------    <-----------    <--------
                 connected                        connected

   IFRAMEs      DLC_INFOs        IFRAMEs        DLC_INFOs      IFRAMEs
<---------->  <------------>  <------------>  <------------>  <-------->

Flow #2 - DLSw Startup Without XIDs (circuit setup)

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                    disconnected

              DLC_CONTACTED   CANUREACH_cs    DLC_START_DL
              ----------->    ----------->    ----------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED
                                <-----------    <-----------
          circuit_established                 circuit_pending
                              REACH_ACK
                              ----------->   circuit_established

                              CONTACT         DLC_CONTACT
                              ----------->    ----------->
              connect_pending                 contact_pending




Wells & Bartky                                                 [Page 50]
^L
RFC 1795                  Data Link Switching                 April 1995


                 DLC_CONTACT       CONTACTED    DLC_CONTACTED
                <-----------    <-----------    <-----------
                 connected                       connected

                DLC_INFOs        IFRAMEs        DLC_INFOs
              <------------>  <------------>  <------------>

   Mapping LAN events to the DLC events and actions on Flow #2 (and
   adding a NETBIOS_NQ and NETBIOS_NR_ex) produces:

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                     disconnected

NAME_QUERY    DLC_DGRM        NETBIOS_NQ_ex   DLC_DGRM       NAME_QUERY
----------->  ----------->    ----------->    ----------->   --------->

   NAME_RECOG    DLC_DGRM      NETBIOS_NR_ex     DLC_DGRM    NAME_RECOG
 <-----------  <------------   <-----------    <-----------  <---------

SABME         DLC_CONTACTED   CANUREACH_cs    DLC_START_DL
----------->  ----------->    ----------->    ----------->
               circuit_start                 resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED
                                <-----------    <-----------
            circuit_established                circuit_pending
                              REACH_ACK
                              ----------->   circuit_established

                              CONTACT         DLC_CONTACT     SABME
                              ----------->    ----------->    --------->
             connect_pending                 contact_pending

          UA   DLC_CONTACT       CONTACTED    DLC_CONTACTED           UA
  <---------  <-----------    <-----------    <-----------    <---------
                connected                       connected

   IFRAMEs       DLC_INFOs       IFRAMEs        DLC_INFOs       IFRAMEs
<------------> <------------> <------------>  <------------>  <-------->





Wells & Bartky                                                 [Page 51]
^L
RFC 1795                  Data Link Switching                 April 1995


   In keeping with a paradigm of 'DLSw is a big 802.2 LAN', all other
   DLC types (SDLC for now, QLLC, channel, or whatever in the future)
   would be handled by a 'DLC transformation layer' that would transform
   the specific protocol's events into the appropriate DLSw DLC events
   and DLSw DLC actions into the appropriate protocol actions.  The XIDs
   that flow in the SSP XIDFRAME should stay 802.2ish (i.e., ABM bit
   set) and leave it up to the DLC transformation layer to suit the XID
   to its particular DLC type.

   Here is an example of a leased SDLC PU 2.0 device as the origin
   station. It should use Flow #2 since it is not known if the other
   side is a LAN, a switched line or a leased line.

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                     disconnected

implementer's  DLC_RESOLVE_C   CANUREACH_ex
choice (power  ----------->    ----------->
up, configuration
change,        DLC_RESOLVE_R   ICANREACH_ex
never,          <-----------    <-----------
connect timer,etc.)

PU 2.0 is
configured
in DLSw to    DLC_XID(null)   CANUREACH_cs    DLC_START_DL
call in       ----------->    ----------->    ----------->
              circuit_start                   resolve_pending

                                ICANREACH_cs   DLC_DL_STARTED
                                <-----------   <-----------
           circuit_established                circuit_pending
                                REACH_ACK
                                ----------->   circuit_established

                              XIDFRAME        DLC_XID
                              ----------->    ----------->

                    DLC_XID        XIDFRAME         DLC_XID
respond with   <-----------    <-----------    <-----------
XID configured



Wells & Bartky                                                 [Page 52]
^L
RFC 1795                  Data Link Switching                 April 1995


for station or
forward XID to
station and
send response  DLC_XID        XIDFRAME        DLC_XID
               ----------->   ----------->    ----------->

        SNRM    DLC_CONTACT       CONTACT      DLC_CONTACTED
  <---------   <-----------    <-----------    <------------
              contact_pending                    connect_pending

UA            DLC_CONTACTED    CONTACTED       DLC_CONTACT
---------->    ----------->    ----------->    ----------->
                connected                       connected

   IFRAMEs       DLC_INFOs        IFRAMEs        DLC_INFOs
<----------->  <------------>  <------------>  <------------>

   Here is an example of a switched SDLC PU 2.0 device as the origin
   station.

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                     disconnected

implementer's  DLC_RESOLVE_C   CANUREACH_ex
choice (power  ----------->    ----------->
up, configuration
change,        DLC_RESOLVE_R   ICANREACH_ex
never,          <-----------    <-----------
connect timer,etc.)

XID(null)     DLC_XID(null)   CANUREACH_cs    DLC_START_DL
----------->  ----------->    ----------->    ----------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED
                                <-----------    <-----------
            circuit_established                 circuit_pending
                                REACH_ACK
                                ----------->   circuit_established





Wells & Bartky                                                 [Page 53]
^L
RFC 1795                  Data Link Switching                 April 1995


                                XIDFRAME      DLC_XID
                                ----------->  ----------->
         XID        DLC_XID         XIDFRAME         DLC_XID
  <---------   <-----------     <-----------    <-----------
XID           DLC_XID         XIDFRAME        DLC_XID
--------->    ----------->    ----------->    ----------->

        SNRM    DLC_CONTACT       CONTACT      DLC_CONTACTED
  <---------   <-----------    <-----------    <-----------
              contact_pending                 connect_pending

UA            DLC_CONTACTED   CONTACTED       DLC_CONTACT
--------->    ----------->    ----------->    ----------->
                 connected                      connected

   IFRAMEs      DLC_INFOs        IFRAMEs        DLC_INFOs
<---------->  <------------>  <------------>  <------------>

   Here is an example of a leased SDLC PU 2.0 device as the target
   station.

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw       Target
 Station        partner                          partner         Station
                                                                 (SDLC)
              disconnected                    disconnected

              DLC_RESOLVE_C   CANUREACH_ex
              ----------->    ----------->   reply if virtual MAC/SAP
                                             for SDLC station is
                                             configured, if SDLC
                                             station responds to
              DLC_RESOLVE_R    ICANREACH_ex  TEST/SNRM/DISC, etc.
               <-----------    <-----------
              DLC_XID         CANUREACH_cs    DLC_START_DL    SNRM
              ----------->    ----------->    ----------->    --------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED        UA
                                <-----------    <-----------    <-------
          circuit_established                 circuit_pending
                                                              RNR
                              REACH_ACK                       --------->
                              ----------->   circuit_established



Wells & Bartky                                                 [Page 54]
^L
RFC 1795                  Data Link Switching                 April 1995


                              XIDFRAME        DLC_XID
                              ----------->    -----------> respond with
                                                           XID configured
                                                           for station
                                                           or forward
                                                           XID to
                                                           station and
                                                           send
                   DLC_XID        XIDFRAME         DLC_XID response
              <-----------    <-----------    <-----------
              DLC_CONTACTED   CONTACT         DLC_CONTACT     RR
              ----------->    ----------->    ----------->    --------->
             connect_pending                contact_pending

                 DLC_CONTACT       CONTACTED    DLC_CONTACTED
                <-----------    <-----------    <-----------
                connected                        connected

                DLC_INFOs        IFRAMEs        DLC_INFOs       IFRAMEs
              <------------>  <------------>  <------------>  <------->

   Here is an example of a switched SDLC PU 2.0 device as the target
   station.

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw       Target
 Station        partner                          partner         Station
                                                                 (SDLC)
              disconnected                    disconnected

              DLC_RESOLVE_C   CANUREACH_ex
              ----------->    ----------->    reply if virtual MAC/SAP
                                              for SDLC station is
                                              configured, if SDLC
                                              station responds to
              DLC_RESOLVE_R     ICANREACH_ex  TEST/XID/SNRM/DISC, etc.
               <-----------     <-----------
              DLC_XID         CANUREACH_cs    DLC_START_DL    XID
              ----------->    ----------->    ----------->    --------->
              circuit_start                   resolve_pending

                                ICANREACH_cs   DLC_DL_STARTED        XID
                                <-----------   <-----------    <--------
          circuit_established                 circuit_pending



Wells & Bartky                                                 [Page 55]
^L
RFC 1795                  Data Link Switching                 April 1995


                              REACH_ACK
                              ----------->   circuit_established

                                XIDFRAME        DLC_XID
                                ----------->    -----------> respond
                                                             with XID
                                                             received
                     DLC_XID        XIDFRAME        DLC_XID  above
                <-----------    <-----------     <---------
             DLC_CONTACTED   CONTACT         DLC_CONTACT     SNRM
             ----------->    ----------->    ----------->    --------->
             connect_pending                  contact_pending

                DLC_CONTACT       CONTACTED    DLC_CONTACTED          UA
               <-----------    <-----------    <-----------    <--------
                connected                        connected

                DLC_INFOs        IFRAMEs        DLC_INFOs       IFRAMEs
              <------------>  <------------>  <------------>  <-------->

   Here is an example of an SDLC T2.1 device as the target station.
   (SDLC T2.1 origin station would look just like the LAN T2.1 origin
   station)

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

              disconnected                    disconnected

              DLC_RESOLVE_C   CANUREACH_ex
              ----------->    ----------->    implementer's choice
                                              (virtual MAC/SAP
                                               configured,
                                               check to see if station
                                               is powered up using
              DLC_RESOLVE_R     ICANREACH_ex   TEST/XID/DISC, etc.)
               <-----------     <-----------
              DLC_XID         CANUREACH_cs    DLC_START_DL    null XID
              ----------->    ----------->    ----------->    --------->
              circuit_start                   resolve_pending

                                ICANREACH_cs    DLC_DL_STARTED       XID
                                <-----------    <-----------    <-------



Wells & Bartky                                                 [Page 56]
^L
RFC 1795                  Data Link Switching                 April 1995


          circuit_established                 circuit_pending
                              REACH_ACK
                              ----------->   circuit_established
                              XIDFRAME        DLC_XID
                              ----------->    ----------->  respond with
                                                            XID received
                     DLC_XID        XIDFRAME        DLC_XID above
                <-----------    <-----------    <----------
                 DLC_XIDs       XIDFRAMEs        DLC_XIDs         XIDs
              <------------>  <------------>  <------------>  <-------->
              DLC_CONTACTED   CONTACT         DLC_CONTACT     SNRM
              ----------->    ----------->    ----------->    --------->
              connect_pending                 contact_pending

                 DLC_CONTACT       CONTACTED    DLC_CONTACTED         UA
                <-----------    <-----------    <-----------    <-------
                connected                        connected

                DLC_INFOs        IFRAMEs        DLC_INFOs       IFRAMEs
              <------------>  <------------>  <------------>  <-------->































Wells & Bartky                                                 [Page 57]
^L
RFC 1795                  Data Link Switching                 April 1995


6.2  Link Restart Protocols

   The following figure depicts the protocol flows that result from
   restarting the end-to-end connection.  This causes the Data Link
   Switches to terminate the existing connection and to enter the
   Circuit Established state awaiting the start of a new connection.

     Data Link   Data Link                     Data Link   Data Link
      Control     Switch                        Switch      Control
     ---------------------                     ---------------------
          +-----------+                             +-----------+
          | Connected |                             | Connected |
    SABME +-----------+                             +-----------+
   ----------->                 RESTART_DL
      DM           ------------------------------------->     DISC
   <-----------                                               -------->
                                                               UA
                         DL_RESTARTED (Case 1)              <--------
                   <-------------------------------------
          +-----------+                             +-----------+
          |Circuit Est|                             |Circuit Est|
          +-----------+                             +-----------+
                        ........... or ...........
    SABME
   ----------->           DL_RESTARTED (Case 2)
       UA          <-------------------------------------
   <-----------                                     +-----------+
                                                    |Circuit Est|
                                CONTACT             +-----------+
      RNR           ------------------------------------>
   <----------

              Figure 5.  DLSw Link Restart Message Protocols

   Upon receipt of a SABME command from the origin station, the origin
   DLSw will send a RESTART_DL message to the target DLSw.  A DM
   response is also returned to the origin station and the data link is
   restarted.

   Upon receipt of the RESTART_DL message, the target DLSw will issue a
   DISC command to the target station.  The target station is expected
   to return a UA response.  The target DLSw will then restart its data
   link and send an DL_RESTARTED message back to the origin DLSw.
   During this exchange of messages, both Data Link Switches change
   states from Connected state to Circuit Established state.

   If the origin station now resends the SABME command, the origin DLSw
   will send a CONTACT message to the target DLSw.  If the SABME command



Wells & Bartky                                                 [Page 58]
^L
RFC 1795                  Data Link Switching                 April 1995


   is received prior to the receipt of the DL_RESTARTED message (case 2
   in the figure), the CONNECT message is delayed until the DL_RESTARTED
   message is received.  The resulting protocol flows at this point
   parallel those given above for the connect sequence.

6.3  Disconnect Protocols

   The following figure depicts the protocol flows that result from the
   end system terminating an existing connection.  Not only is the
   connection terminated, but the circuit between the Data Link Switches
   is taken down.

     Data Link  Data Link                      Data Link  Data Link
      Control    Switch                         Switch     Control
     --------------------                      --------------------
          +-----------+                             +-----------+
          | Connected |                             | Connected |
          +-----------+                             +-----------+
      DISC
   ---------->                  HALT_DL
       UA         ------------------------------------->      DISC
   <----------                                              --------->
                                                               UA
                               DL_HALTED                    <--------
                  <-------------------------------------
          +-----------+                             +-----------+
          |Disconnectd|                             |Disconnectd|
          +-----------+                             +-----------+

                          ......... or ..........

          +-----------+                             +-----------+
          | Connected |                             | Connected |
          +-----------+                             +-----------+
       DISC              TCP Connection Failure               DISC
   <--------     <------------------------------------>    --------->
        UA                                                     UA
    -------->                                               <--------
          +-----------+                             +-----------+
          |Disconnectd|                             |Disconnectd|
          +-----------+                             +-----------+

               Figure 6.  DLSw Disconnect Message Protocols

   Upon receipt of a DISC command from the origin station, the origin
   DLSw will reply with a UA response and issue a HALT_DL message to the
   target DLSw.  Upon receipt of the HALT_DL message, the target DLSw
   will send a DISC command to the target station.  The target station



Wells & Bartky                                                 [Page 59]
^L
RFC 1795                  Data Link Switching                 April 1995


   will then respond with a UA response, causing the target DLSw to
   return a DL_HALTED message to the origin DLSw.  During this exchange
   of messages, both Data Link Switches change states from the Connected
   state to the Disconnected state.

   If the TCP connection between two Data Link Switches fails, all
   connections that are currently multiplexed on the failed TCP
   connection will be taken down.  This implies that both Data Link
   Switches will send DISC commands to all the local systems that are
   associated with the failed connections.  Upon sending the DISC
   command, the Data Link Switch will enter the DISCONNECTED state for
   each circuit.

7.0  Capabilities Exchange Formats/Protocol

   The Data Link Switching Capabilities Exchange is a special DLSw
   Switch-to-Switch control message that describes the capabilities of
   the sending data link switch. This control message is sent after the
   switch-to-switch connection is established and optionally during run
   time if certain operational parameters have changed and need to be
   communicated to the partner switch.

   The actual contents of the Capabilities Exchange is in the data field
   following the SSP message header.  The Capabilities Exchange itself
   is formatted as a single General Data Stream (GDS) Variable with
   multiple type "LT" structured subfields.

   The SSP Message Header has the following fields set for the
   Capabilities Exchange:

   Offset   Field                 Value
   ------   -----                 -----
   0x00     Version Number        0x31
   0x01     Header Length         0x48 (decimal 72)
   0x02     Message Length        same as LL in GDS Variable
   0x14     Message Type          0x20 (CAP_EXCHANGE)
   0x16     Protocol Id           0x42
   0x17     Header Number         0x01
   0x23     Message Type          0x20 (CAP_EXCHANGE)
   0x38     Direction             0x01 for CapEx request
                                  0x02 for CapEx response

   Other fields in the SSP header are not referenced and should be set
   to zero.







Wells & Bartky                                                 [Page 60]
^L
RFC 1795                  Data Link Switching                 April 1995


   The DLSw Capabilities Exchange Request has the following overall
   format:

   +----+----+-----------------+
   | LL | ID | Control Vectors |
   +----+----+-----------------+

   0-1         Length, in binary, of the DLSw Capabilities
               Exchange
               Request GDS Variable.  The value of LL is
               the sum of the length of all fields in the
               GDS Variable (i.e., length of LL + length of ID
               + length of Control Vectors).

   2-3         GDS Id: 0x1520

   4-n         Control Vectors consisting of type LT structured
               subfields (i.e., the DLSw Capabilities Exchange
               Structured Subfields)

   Type LT structured subfields consist of a 1-byte length field (the
   "L"), a 1-byte type field (the "T") and n-bytes of data.  The length
   field includes itself as well as the structured subfield.  The
   structured subfield consists of the type field and data so the length
   is n + 2. This imposes a length restriction of 253 bytes on all data
   contained in a structured subfield.

























Wells & Bartky                                                 [Page 61]
^L
RFC 1795                  Data Link Switching                 April 1995


7.1  Control Vector Id Range

   Control Vector identifiers (i.e., Type) in the range of 0x80 through
   0xCF are reserved for use by the Data Link Switching standard.

   Control Vector identifiers (i.e., Type) in the range of 0xD0 through
   0xFD are used for vendor-specific purposes.

   Currently defined vectors are:

   Vector Description                       Hex Value

   Vendor Id Control Vector                 0x81
   DLSw Version Control Vector              0x82
   Initial Pacing Window Control Vector     0x83
   Version String Control Vector            0x84
   Mac Address Exclusivity Control Vector   0x85
   Supported SAP List Control Vector        0x86
   TCP Connections Control Vector           0x87
   NetBIOS Name Exclusivity Control Vector  0x88
   MAC Address List Control Vector          0x89
   NetBIOS Name List Control Vector         0x8A
   Vendor Context Control Vector            0x8B
   Reserved for future use                  0x8C - 0xCF
   Vendor Specific                          0xD0 - 0xFD

7.2  Control Vector Order and Continuity

   Since their contents can greatly affect the parsing of the
   Capabilities Exchange GDS Variable, the required control vectors must
   occur first and appear in the following order:  Vendor Id, DLSw
   Version Number, Initial Pacing Window, Supported SAP List. The
   remainder of the Control Vectors can occur in any order.

   Control Vectors that can be repeated within the same message (e.g.,
   MAC Address List Control Vector and NetBIOS Name List Control Vector)
   are not necessarily adjacent.  It is advisable, but not required, to
   have the Exclusivity Control Vector occur prior to either of the
   above two vectors so that the use of the individual MAC addresses or
   NetBIOS names will be known prior to parsing them.

   Both the Vendor Context and Vendor Specific control vectors can be
   repeated.  If there are multiple instances of the Vendor Context
   control vector, the specified context remains in effect for all
   Vendor Specific control vectors until the next Vendor Context control
   vector is encountered in the Capabilities Exchange.





Wells & Bartky                                                 [Page 62]
^L
RFC 1795                  Data Link Switching                 April 1995


7.3  Initial Capabilities Exchange

   Capabilities exchange is always the first SSP message sent on a new
   SSP connection between two DLSw switches.  This initial Capabilities
   Exchange is used to identify the DLSw version that each switch is
   running and other required information, plus details of any optional
   extensions that the switches are capable of supporting.

   If a DLSw receives an initial capabilities message that is
   incorrectly formatted or contains invalid or unsupported data that
   prevents correct interoperation with the partner DLSw, it should
   issue a Capabilities Exchange negative response.

   If a DLSw receives a negative response to its initial capabilities
   message, it should take down its TCP connections with the offended
   partner.

   Note:  Pre v1.0 DLSw implementations do not send or respond to
   capabilities messages and can be identified by the lack of
   capabilities exchange as the first message on a new SSP connnection.
   This document does not attempt to specify how to interoperate with
   back-level DLSw implementations.

7.4  Run-Time Capabilities Exchange

   Capabilities exchange always occurs when the SSP connection is
   started between two DLSw switches.  Capabilities Exchange can also
   occur at run-time, typically when a configuration change is made.

   Support for run-time Capabilities Exchange is optional.  If a node
   does not support receiving/using Run-Time Capabilities Exchange and
   receives one, it should discard it quietly (not send back a negative
   response).  If a node supports receipt of run-time capabilities, it
   should send a positive or negative response as appropriate.  The
   receiver of a negative response to a run-time capabilities message is
   not required to take down its TCP connections with the offended
   partner.

   Run-time Capabilities Exchange can consist of one or more of the
   following control vectors.  Note that the control vectors required at
   start-up are not present in a run-time Capabilities Exchange.










Wells & Bartky                                                 [Page 63]
^L
RFC 1795                  Data Link Switching                 April 1995


        1. MAC Address Exclusivity CV,
        2. NetBIOS Name Exclusivity CV,
        3. MAC Address List CV,
        4. NetBIOS Name List CV,
        5. Supported SAP List CV,
        6. Vendor Context CV,
        7. Vendor Specific CVs

   A run-time capabilities exchange is a replacement operation.  As
   such, all pertinent MAC addresses and NetBIOS names must be specified
   in the run-time exchange. In addition, run-time changes in
   capabilities will not effect existing link station circuits.

7.5  Capabilities Exchange Filtering Responsibilities

   Recipients of the SAP, MAC, and NetBIOS lists are not required to
   actually use them to filter traffic, etc., either initially or at
   run-time.

7.6  DLSw Capabilities Exchange Structured Subfields

   The Capabilities Exchange Subfields are listed in the table below and
   are described in the following sections:

         Required                      Allowed @
    ID   @ Startup  Length  Repeatable* Runtime  Order  Content
   ====  =========  ======  ==========  =======  =====  ===============
   0x81     Y        0x05        N         N       1    Vendor ID

   0x82     Y        0x04        N         N       2    DLSw Version

   0x83     Y        0x04        N         N       3    Initial pacing
                                                        window

   0x84     N      >=0x02        N         N       5+   Version String

   0x85     N        0x03        N         Y       5+   MAC Address
                                                        Exclusivity

   0x86     Y        0x12        N         Y       4    Supported SAP
                                                        List

   0x87     N        0x03        N         N       5+   TCP Connections

   0x88     N        0x03        N         Y       5+   NetBIOS Name
                                                        Exclusivity





Wells & Bartky                                                 [Page 64]
^L
RFC 1795                  Data Link Switching                 April 1995


   0x89     N        0x0E        Y         Y       5+   MAC Address
                                                        List

   0x8A     N      <=0x13        Y         Y       5+   NetBIOS Name
                                                        List

   0x8B     N        0x05        Y         Y       5+   Vendor Context

   0xD0     N       varies       Y         Y       5+   Vendor Specific

   *Note: "Repeatable" means a Control Vector is repeatable within a single
   message.

7.6.1  Vendor Id (0x81) Control Vector

   The Vendor Id control vector identifies the manufacturer's IEEE
   assigned Organizationally Unique Identifier (OUI) of the Data Link
   Switch sending the DLSw Capabilities Exchange.  The OUI is sent in
   non-canonical (Token-Ring) format.  This control vector is required
   and must be the first control vector.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x05   Length of the Vendor Id structured
                          subfield

      1       1    0x81   key = 0x81  that identifies this as the
                          Vendor Id structured subfield

     2-4      3           the 3-byte Organizationally Unique
                          Identifier (OUI) for the vendor
                          (non-canonical format)

7.6.2  DLSw Version (0x82) Control Vector

   The DLSw Version control vector identifies the particular version of
   the DLSw standard supported by the sending Data Link Switch.  This
   control vector is required and must follow the Vendor Id Control
   Vector.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x04   Length of the Version String structured
                          subfield

      1       1    0x82   key = 0x82  that identifies this as the
                          DLSw Version structured subfield




Wells & Bartky                                                 [Page 65]
^L
RFC 1795                  Data Link Switching                 April 1995


      2       1           the hexadecimal value representing the
                          DLSw standard Version number of the
                          sending Data Link Switch.
                            0x01 (indicates version 1 - closed pages)

      3       1           the hexadecimal value representing the
                          DLSw standard Release number of the
                          sending Data Link Switch.
                            0x00 (indicates release 0)

7.6.3  Initial Pacing Window (0x83) Control Vector

   The Initial Pacing Window control vector specifies the initial value
   of the receive pacing window size for the sending Data Link Switch.
   This control vector is required and must follow the DLSw Version
   Control Vector.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x04   Length of the Initial Pacing Window
                          structured subfield

      1       1    0x83   key = 0x83  that identifies this
                          as the Initial Pacing Window
                          structured subfield

     2-3      2           the pacing window size, specified
                          in byte normal form..

   Note:  The pacing window size must be non-zero.

7.6.4  Version String (0x84) Control Vector

   The Version String control vector identifies the particular version
   number of the sending Data Link Switch.  The format of the actual
   version string is vendor-defined.  This control vector is optional.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0xn    Length of the Version String
                          structured subfield

      1       1    0x84   key = 0x84  that identifies
                          this as the Version String
                          structured subfield






Wells & Bartky                                                 [Page 66]
^L
RFC 1795                  Data Link Switching                 April 1995


     2-n     n-2          the ASCII string that identifies
                          the software version for the
                          sending DLSw.

7.6.5  MAC Address Exclusivity (0x85) Control Vector

   The MAC Address Exclusivity control vector identifies how the MAC
   Address List control vector data is to be interpreted.  Specifically,
   this control vector identifies whether the MAC addresses in the MAC
   Address List control vectors are the only ones accessible via the
   sending Data Link Switch.

   If a MAC Address List control vector is specified and the MAC Address
   Exclusivity control vector is missing, then the MAC addresses are not
   assumed to be the only ones accessible via this switch.

   A node may specify that it supports no local MAC addresses by
   including in its capabilities the MAC Address List Exclusivity CV
   (with byte 2 == 0x01), and not including any instances of the MAC
   Address List CV.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x03   Length of the Exclusivity structured
                          subfield

      1       1    0x85   key = 0x85 that identifies this as the
                          MAC address Exclusivity structured
                          subfield

      2       1           an indicator of the relationship of the
                          MAC addresses to the sending Data Link
                          Switch.
                            0x00     the MAC addresses specified in
                                     this Capabilities Exchange
                                     can be accessed via this
                                     switch but are not the
                                     exclusive set (i.e., other
                                     entities are accessible in
                                     addition to the ones specified)
                            0x01     the MAC addresses specified in
                                     this Capabilities Exchange
                                     are the only ones accessible
                                     via this switch.







Wells & Bartky                                                 [Page 67]
^L
RFC 1795                  Data Link Switching                 April 1995


7.6.6  SAP List Support (0x86) Control Vector

   The SAP List Support control vector identifies support for Logical
   Link Control SAPs (DSAPs and SSAPs) by the sending Data Link Switch.
   This is used by the DLSw that sent the SAP List Support control
   vector to indicate which SAPs can be used to support SNA and
   optionally NetBIOS traffic.  This may be used by the DLSw that
   receives the SAP list to filter explorer traffic (TEST, XID, or
   NetBIOS UI frames) from the DLSw state machine.  For SNA, a DLSw
   should set bits for all SAP values (SSAP or DSAP) that may be used
   for SNA traffic.  For NetBIOS support, the bit for SAP 0xF0 should be
   set (if not supported then the same bit should be cleared).

   Each bit in the SAP control vector data field represents a SAP as
   defined below.  This vector is required and must follow the Initial
   Pacing Window Control Vector.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1     0x12  Length of the Supported SAP List structured
                          subfield

      1       1     0x86  key = 0x86 that identifies this as the
                          Supported SAP List structured subfield

     2-17    16           the 16-byte bit vector describing all
                          even numbered SAPs enabled.

                          Each Bit within the 16 byte bit vector will
                          indicate whether an even numbered SAP is
                          enabled (b'1') or disabled (b'0').

                          Each Byte within the 16 byte bit vector
                          will be numbered from 0 - F. (Most
                          significant byte first).

                          Byte 0   1   2   3   ...   F
                               XX  XX  XX  XX  ...   XX

                          The bits in each byte indicate whether an
                          even numbered SAP is enabled (b'1') or
                          disabled (b'0'). (Most significant bit first)

                          Bits 7   6   5   4   ...   0
                          SAP  0   2   4   6   ...   E

                          By combining the byte label with the enabled
                          bits, all supported SAPs can be determined.



Wells & Bartky                                                 [Page 68]
^L
RFC 1795                  Data Link Switching                 April 1995


                          In the following diagram, 'n' would equal 0
                          through F depending on which byte was being
                          interpreted.

                          Bit ordering is shown below with bit
                          7 being the most significant bit and bit
                          0 the least significant bit.

                          7654 3210
                          bbbb bbbb....
                          |||| ||||
                          |||| |||SAP 0xnE enabled or not
                          |||| |||
                          |||| ||SAP 0xnC enabled or not
                          |||| ||
                          |||| |SAP 0xnA enabled or not
                          |||| |
                          |||| SAP 0xn8 enabled or not
                          ||||
                          |||SAP 0xn6 enabled or not
                          |||
                          ||SAP 0xn4 enabled or not
                          ||
                          |SAP 0xn2 enabled or not
                          |
                          SAP 0xn0 enabled or not

























Wells & Bartky                                                 [Page 69]
^L
RFC 1795                  Data Link Switching                 April 1995


   An example of using all User Definable SAPs of 0x04 to 0xEC for SNA
   Data Link Switching and SAP 0xF0 for NetBIOS Data Link Switching
   would be as follows:

   Offset  SAPs          Binary       Hex

   0       4,8,C         0010 1010    0x2A
   1       10,14,18,1C   1010 1010    0xAA
   2       20,24,28,2C   1010 1010    0xAA
   3       30,34,38,3C   1010 1010    0xAA
   4       40,44,48,4C   1010 1010    0xAA
   5       50,54,58,5C   1010 1010    0xAA
   6       60,64,68,6C   1010 1010    0xAA
   7       70,74,78,7C   1010 1010    0xAA
   8       80,84,88,8C   1010 1010    0xAA
   9       90,94,98,9C   1010 1010    0xAA
   A       A0,A4,A8,AC   1010 1010    0xAA
   B       B0,B4,B8,BC   1010 1010    0xAA
   C       C0,C4,C8,CC   1010 1010    0xAA
   D       D0,D4,D8,DC   1010 1010    0xAA
   E       E0,E4,E8,EC   1010 1010    0xAA
   F       F0            1000 0000    0x80

7.6.7  TCP Connections (0x87) Control Vector

   The TCP Connections control vector indicates the support of an
   alternate number of TCP Connections for the Data Link Switching
   traffic.  The base implementation of Data Link Switching supports two
   TCP Connections, one for each direction of data traffic.

   This control vector is optional.  If it is omitted in a DLSw
   Capabilities Exchange, then two TCP Connections are assumed.  It is
   further assumed that if a Data Link  Switch can support one TCP
   Connection, it can support two TCP Connections.

   If TCP Connections CV values agree and the number of connections is
   one, then the  DLSw with the higher IP address must tear down the TCP
   connections on its local port 2065.

   The format of the TCP Connections Control Vector is shown below:

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x03   Length of the TCP Connections structured
                          subfield

      1       1    0x87   key = 0x87  that identifies this as the
                          TCP Connections structured subfield



Wells & Bartky                                                 [Page 70]
^L
RFC 1795                  Data Link Switching                 April 1995


      2       1           an indicator of the support for an
                          alternate number of TCP Connections by
                          the sending Data Link Switch.
                            0x01      the number of TCP Connections
                                      may be brought down to one
                                      after Capabilities Exchange
                                      is completed.
                            0x02      the number of TCP Connections
                                      will remain at two for
                                      the duration of the DLSw
                                      connection.

7.6.8  NetBIOS Name Exclusivity (0x88) Control Vector

   The NetBIOS Name Exclusivity control vector identifies how the
   NetBIOS Name List control vector data is to be interpreted.
   Specifically, this control vector identifies whether the NetBIOS
   Names in the NetBIOS Name List control vectors are the only ones
   accessible via the sending Data Link Switch.

   If a NetBIOS Name List control vector is specified and the NetBIOS
   Name Exclusivity control vector is missing, then the NetBIOS Names
   are not assumed to be the only  ones accessible via this switch.

   A node may specify that it supports no local NetBIOS names by
   including in its  capabilities the NetBIOS Name List Exclusivity CV
   (with byte 2 == 0x01), and not including any instances of the NetBIOS
   Name List CV.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x03   Length of the Exclusivity structured
                          subfield

      1       1    0x88   key = 0x88 that identifies this as the
                          NetBIOS Name Exclusivity structured
                          subfield

      2       1           an indicator of the relationship of the
                          NetBIOS Names to the sending Data Link
                          Switch.
                            0x00     the NetBIOS Names specified in
                                     this Capabilities Exchange
                                     can be accessed via this
                                     switch but are not the
                                     exclusive set (i.e., other
                                     entities are accessible in
                                     addition to the ones specified)



Wells & Bartky                                                 [Page 71]
^L
RFC 1795                  Data Link Switching                 April 1995


                            0x01     the NetBIOS Names specified in
                                     this Capabilities Exchange
                                     are the only ones accessible
                                     via this switch.

7.6.9  MAC Address List (0x89) Control Vector

   The MAC Address List control vector identifies one or more MAC
   addresses that are accessible through the sending Data Link Switch.
   This control vector specifies a single MAC address value and MAC
   address mask value to identify the MAC address or range of MAC
   addresses.  MAC addresses and masks are in non-canonical (Token-Ring)
   format in this control vector.

   This control vector is optional and can be repeated if necessary.

   Note 1: If a particular MAC address, <mac-addr>, satisfies the
   following algorithm, then <mac-addr> is assumed to be accessible via
   the sending Data Link Switch:

   <mac-addr> & <mac-addr-mask> == <mac-addr-value>

   where:  <mac-addr-value> is the MAC Address
                            Value specified in
                            this control vector

           <mac-addr-mask>  is the MAC Address
                            Mask specified in
                            this control vector

   Note 2:  If an individual MAC Address is desired, then <mac-addr-
   value> should be the individual MAC address and <mac-addr-mask>
   should be 0xFFFFFFFFFFFF.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0x0E   Length of the MAC Address List
                          structured subfield

      1       1    0x89   key = 0x89  that identifies this as the
                          MAC Address List structured subfield

     2-7      6           the 6-byte MAC Address Value,
                          <mac-addr-value> in the above formula

     8-13     6           the 6-byte MAC Address Mask,
                          <mac-addr-mask> in the above formula




Wells & Bartky                                                 [Page 72]
^L
RFC 1795                  Data Link Switching                 April 1995


7.6.10  NetBIOS Name List (0x8A) Control Vector

   The NetBIOS Name List control vector identifies one or more NetBIOS
   names that are accessible through the sending Data Link Switch.  This
   control vector specifies a single NetBIOS name in ASCII.  However,
   the NetBIOS name can consist of "don't care" and "wildcard"
   characters to match on a number of NetBIOS names.  If an individual
   character position in the NetBIOS name in this control vector
   contains a '?', then the corresponding character position in real
   NetBIOS name is a "don't care".  If a NetBIOS name in this control
   vector ends in '*', then the remainder of real NetBIOS names is a
   "don't care".  '*' is only considered a wildcard if it appears at the
   end of a name.

   All blanks or nulls at the end of NetBIOS names in this control
   vector are ignored.   NetBIOS names which have fewer than 16 bytes
   and which do not end with  '*' are not assumed to have a trailing
   '*'; the "wildcard" character must be explicit.

   NetBIOS group names can exist across several LANs/networks.  As such,
   NetBIOS  group names received in a NetBIOS Name List Control Vector
   can not be treated the same as NetBIOS individual names.  The
   Individual/Group Flag allows Data  Link Switches to distinguish
   between the two.

   This control vector is optional and can be repeated if necessary.

   Offset  Length  Value  Contents
   ------  ------  -----  --------
      0       1    0xn    Length of the NetBIOS Name List
                          structured subfield (maximum = 0x13)

      1       1    0x8A   key = 0x8A  that identifies this as the
                          NetBIOS Name List structured subfield

      2       1           Individual/Group Flag
                            0x00 - Individual NetBIOS Name
                            0x01 - Group NetBIOS Name

     3-n     n-3          the NetBIOS name with possible embedded
                          '?' and terminating '*'.

7.6.11  Vendor Context (0x8B) Control Vector

   The Vendor Context control vector identifies the manufacturer's IEEE
   assigned Organizationally Unique Identifier (OUI) of the Data Link
   Switch sending the DLSw Capabilities Exchange.  The OUI is sent in
   non-canonical (Token-Ring) format.



Wells & Bartky                                                 [Page 73]
^L
RFC 1795                  Data Link Switching                 April 1995


   This control vector is optional and is used to provide the context
   for any Vendor Specific control vectors that follow in the
   Capabilities Exchange.  If there are multiple instances of the Vendor
   Context control vector, the specified context remains in effect for
   all Vendor Specific control vectors until the next Vendor Context
   control vector is encountered.

      Offset  Length  Value  Contents
      ------  ------  -----  --------
         0       1    0x05   Length of the Vendor Context structured
                             subfield

         1       1    0x8B   key = 0x8B  that identifies this as the
                             Vendor Context structured subfield

        2-4      3           the 3-byte Organizationally Unique
                             Identifier (OUI) for the vendor
                             (non-canonical format)

7.7  Capabilities Exchange Responses

   There are two kinds of DLSw Capabilities Exchange Responses: positive
   and negative.  A positive response is returned to the sending Data
   Link Switch if there were no errors encountered in the DLSw
   Capabilities Exchange Request.  A negative response is returned if
   there is at least one error encountered.

   A positive DLSw Capabilities Exchange Response has the following
   overall format:

   +----+----+
   | LL | ID |
   +----+----+

   0-1    Length, in binary, of the DLSw Capabilities
          Exchange Response GDS Variable.  The value of
          LL in this case is 0x0004.

   2-3    GDS Id: 0x1521

   A negative DLSw Capabilities Exchange Response has the following
   overall format:

   +----+----+--------+--------+
   | LL | ID | Offset | Reason |
   +----+----+--------+--------+





Wells & Bartky                                                 [Page 74]
^L
RFC 1795                  Data Link Switching                 April 1995


   0-1    Length, in binary, of the DLSw Capabilities Exchange
          Response GDS Variable.  The value of LL is the sum of
          the length of all fields in the GDS Variable (i.e.,
          length of LL + length of ID + length of Offsets/Reasons).

   2-3    GDS Id: 0x1522

   4-5    Offset into the DLSw Capabilities Exchange Request of the
          error.  Offset should always point to the start of the
          GDS Variable or a specific control vector.

   6-7    Reason code that uniquely identifies the error.  Specific
          values for the reason code are:

            0x0001        invalid GDS length for a DLSw Capabilities
                          Exchange Request.  (The value of Offset
                          is ignored.)

            0x0002        invalid GDS id for a DLSw Capabilities
                          Exchange Request.  (The value of Offset
                          is ignored.)

            0x0003        Vendor Id control vector is missing.  (The
                          value of Offset is ignored.)

            0x0004        DLSw Version control vector is missing. (The
                          value of Offset is ignored.)

            0x0005        Initial Pacing Window control vector is
                          missing.  (The value of Offset is ignored.)

            0x0006        length of control vectors doesn't correlate
                          to the length of the GDS variable

            0x0007        invalid control vector id

            0x0008        length of control vector invalid

            0x0009        invalid control vector data value

            0x000A        duplicate control vector (for non-repeating
                          control vectors)

            0x000B        out-of-sequence control vector (for
                          repeating control vector)

            0x000C        DLSw Supported SAP List control vector is
                          missing.



Wells & Bartky                                                 [Page 75]
^L
RFC 1795                  Data Link Switching                 April 1995


                          (The value of Offset is ignored.)

   Note:  Multiple Offset, Reason pairs can be returned with one pair
   for each error encountered.

8.  Pacing/Flow Control

   This section describes the required Pacing and Flow Control
   mechanisms used by a Data Link Switch.

   While it is beyond the scope of this document to specify a policy for
   how an implementation maps SSP flow control to the native data link
   flow control at the edges, the following paragraphs describe a
   general philosophical overview of how the mechanism is to be applied.

   There are two types of flows which are covered by the flow control
   mechanism: connection-oriented and connectionless.  In the first,
   connection-oriented flows, the implementer is to map the native flow
   control mechanism of the two data links at the boundaries to the SSP
   flow control mechanism thus presenting an end-to-end flow control
   mechanism which "pushes back" all the way to the originating station
   in either direction.

   However, in the case of connectionless traffic, this is not possible
   at the data link level because there is no native flow control
   mechanism for connectionless data links.  At first glance it is
   tempting to allow connectionless traffic to flow the DLSw cloud
   unthrottled.  However, the rationale for subjecting these flows to
   flow control within the DLSw cloud is to "push" the discarding of
   frames (should this become necessary) back to the ingress of the DLSw
   cloud.  This "early discarding" of excessive DATAGRAMs should allow
   the cloud to remain deterministic without wasting network bandwidth.

8.1  Basic Overview

   Each circuit consists of two data flows, one in each direction.  Each
   data flow has its own independent flow control mechanism.  For each
   data flow there is an entity that originates traffic, referred to as
   the sender, and a target entity which receives the traffic, referred
   to as the receiver.

   A sender may only send data when its receiver has granted explicit
   permission to send a discrete number of data units.  Data units are
   defined as either a DGRMFRAME or an INFOFRAME.

   The receiver grants permission to send data units by sending a Flow
   Control Indicator (FCIND- defined later).  The sender must
   acknowledge all FCINDs by sending a Flow Control Acknowledgment



Wells & Bartky                                                 [Page 76]
^L
RFC 1795                  Data Link Switching                 April 1995


   (FCACK- defined later).

   A sending implementation must maintain these values:

   1. GrantedUnits - The number of units (frames) which the sender
      currently has permission to send.

   2. CurrentWindow - This is a discrete number of units, controlled by
      the receiver, which is basis for granting additional units.

   3. InitialWindowSize - Global for all circuits on a transport
      connection.  Learned in capabilities exchange when the transport
      connection is established.  It specifies an initial value for
      CurrentWindow when each circuit is established.

   A receiving implementation must maintain these values:

   1. CurrentWindow - This is a discrete number of units, controlled by
      the receiver, which is basis for granting additional units.

   2. InitialWindowSize - Global for all circuits on a transport
      connection.  Sent in capabilities exchange when the transport
      connection is established.  It specifies an initial value for
      CurrentWindow when each circuit is established.

   3. FCACKOwed - The sender owes an FCACK.  If true, no FCIND may be
      sent.

8.2  Frame Format

   The Flow control Byte is contained at offset 15 in both the
   Information and Control SSP messages.  From a flow control
   perspective, the flow control information in the two frames are
   handled identically.

   The following diagram describes the format of the Flow Control Byte
   (Bit 7 is the most significant and Bit 0 is the Least significant bit
   of the octet):

      bit   7   6   5   4   3   2   1   0
          +---+---+---+---+---+---+---+---+
          |FCI|FCA| reserved  |    FCO    |
          +---+---+---+---+---+---+---+---+

      FCI : Flow Control Indicator
      FCA : Flow Control Ack
      FCO : Flow Control Operator Bits




Wells & Bartky                                                 [Page 77]
^L
RFC 1795                  Data Link Switching                 April 1995


            000 - Repeat Window Operator
            001 - Increment Window Operator
            010 - Decrement Window Operator
            011 - Reset Window Operator
            100 - Halve Window Operator
            101 - Reserved
            110 - Reserved
            111 - Reserved

   A frame with the FCI bit set is referred to as a Flow Control
   Indication (FCIND).  An FCIND is used to manage the flow in the
   opposite direction of the frame which bears it.

   A frame with the FCA bit set is referred to as a Flow Control
   Acknowledgment (FCACK).  An FCACK is used to manage the flow in the
   same direction of the frame which bears it.

   NOTE:  A frame may be both a FCIND and an FCACK.

   A frame bearing an FCIND or FCACK may also contain data for the flow
   in the direction it is traveling.  In such a frame, the FCIND or
   FCACK are said to be piggy-backed.  A non-piggy-backed FCIND is
   called an Independent Flow Control Indication (IFCIND) and a non-
   piggy-backed FCACK is called an Independent Flow Control
   Acknowledgment (IFCACK). IFCIND and IFCACK messages are sent in a
   Independent Flow Control SSP message (type 0x21).

   NOTE:  A frame may be both an IFCIND and an IFCACK.

   It is desirable to carry information in control messages so as to
   reduce the need to send a flow control only message.  The diagram
   below shows the messages that may carry valid flow control
   information:

 ======                            ___                           ======
 |    |        ---------        __/   \__       ---------        |    |
 |    |      __|  _|_  |__     /   IP    \    __|  _|_  |__      |    |
 ======        |   |   |      <  Network  >     |   |   |        ======
/______\       ---------       \__     __/      ---------       /______\
 Origin       Origin DLSw         \___/        Target DLSw      Target
 Station        partner                          partner        Station

   May have valid
    FCI/FCA/FCO    Data carrying

         N             N          CANUREACH_cs
                                  ----------->
         Y*            N            ICANREACH_cs



Wells & Bartky                                                 [Page 78]
^L
RFC 1795                  Data Link Switching                 April 1995


                                    <-----------
         Y             N          REACH_ACK
                                  ----------->
         Y             Y            XIDFRAMEs
                                  <------------>
         Y             Y            DGRMFRAMEs
                                  <------------>
         Y             N          CONTACT
                                  ----------->
         Y             N               CONTACTED
                                    <-----------
         Y             Y             INFOFRAMEs
                                  <------------>
         Y             N          RESTART_DL
                                  ----------->
         Y             N               DL_RESTARTED
                                    <-----------
         Y             N          CONTACT
                                  ----------->
         Y             N               CONTACTED
                                    <-----------
         N             N          HALT_DL
                                  ----------->
         N             N               DL_HALTED
                                    <-----------

   *Note: ICANREACH_cs cannot carry FCA, as there could not be an
   outstanding FCI.

8.3  Granting Permission to Send Data

   A receiver grants a sender permission to send units of data by
   sending FCIND.  Each FCIND is further qualified by a flow control
   operator, which is encoded in the FCO bits of the FCIND header. With
   one exception (the Reset Window operator) all operators may be either
   piggy-backed or carried in a IFCIND.

   The five flow control operators are outlined below:

8.3.1  Repeat Window Operator

   This operator is processed as follows:

           (CurrentWindow unchanged)
           GrantedUnits += CurrentWindow






Wells & Bartky                                                 [Page 79]
^L
RFC 1795                  Data Link Switching                 April 1995


8.3.2  Increment Window Operator

   This operator is processed as follows:

           CurrentWindow++
           GrantedUnits += CurrentWindow

8.3.3  Decrement Window Operator

   This operator is processed as follows:

           CurrentWindow--
           GrantedUnits += CurrentWindow

   NOTE:  This operator may only be sent if CurrentWindow is greater
   than one.

8.3.4  Reset Window Operator

   This operator is processed as follows:

           CurrentWindow = 0;
           GrantedUnits  = 0;

   NOTE:  This operator may only flow on an independent pacing
   indication (may NOT be piggy-backed).

   NOTE:  After sending this operator, the only legal subsequent
   operator is Increment Window.

8.3.5  Halve Window Operator

   This operator shall be processed as follows:

           IF CurrentWindow > 1 THEN
               CurrentWindow = CurrentWindow / 2
           ENDIF
           GrantedUnits += CurrentWindow

   Note:  The divide by two operation is an unsigned integer divide
   (round down) or bit shift right operation.

8.4  Acknowledging a Flow Control Operator

   Each sender must acknowledge each FCIND with an FCACK which is
   piggy-backed on the next frame in the opposite direction in all cases
   except the Reset Window Operator.




Wells & Bartky                                                 [Page 80]
^L
RFC 1795                  Data Link Switching                 April 1995


   The receiver may have no more than one unacknowledged FCIND
   outstanding at any time with one exception:  A Reset Window Operator
   may be sent while another FCIND is pending acknowledgment.

   NOTE: The FCI and FCO bits of the FCACK are used independently by the
   flow in the opposite direction

8.4.1  Acknowledging a Reset Window Operator

   Since this operator revokes all previously granted units, the sender
   must acknowledge this FCIND using an IFCACK (Independent Flow Control
   Acknowledgment).  This is the only case where IFCACK is used.

   Should a sender receive a non-reset FCIND followed by a Reset Window
   FCIND before acknowledging the first, it only acknowledges the Reset
   Window.

   NOTE: The FCI and FCO bits on these frames are used independently by
   the flow in the opposite direction.

8.5  Capabilities Exchange Initial Window Size

   When two nodes establish a transport connection, they engage in a
   capabilities exchange (this is a requirement).  Refer to the
   Capabilities Exchange section 7 for further details.  The two nodes
   are required to exchange the following parameter:

   InitialWindowSize -  This indicates to the partner what
                        the sending flow entity initializes
                        its CurrentWindow value to for each
                        multiplexed circuit subsequently
                        established on that transport
                        connection.  This value must be
                        non-zero.

8.6  Circuit Startup

   Process as follows:

          CurrentWindow = InitialWindowSize
          GrantedUnits  = 0

   NOTE: The InitialWindow Size variable has a scope of one per DLSw
   transport connection, while CurrentWindow and Granted units are
   maintained on a per circuit basis.  At circuit startup, a sender may
   not send data units until the receiver grants explicit permission
   with an FCIND message.  This grant may be an independent FCIND
   message or the FCIND may be piggy-backed on any of the message types



Wells & Bartky                                                 [Page 81]
^L
RFC 1795                  Data Link Switching                 April 1995


   listed in section 8.2.

8.7  Example Receiving Implementations

   The following two examples illustrate receiving implementations of
   varying degrees of complexity.  These are not meant to be complete
   implementations but rather serve to illustrate the protocol.

   NOTE: The examples are independent of the buffering model ( buffers
   may be deterministicly or statistically committed)

   NOTE: The examples assume a process model where each event processes
   to completion without being preempted by another event.

8.7.1  Fixed Pacing Example

   Consider the following variables, in addition to InitialWindowSize
   and CurrentWindow and FCACKOwed:

          GrantDelayed     - Boolean
          GrantedUnits     - Outstanding Units

   The following section describes how various events are processed in
   this example implementation:

8.7.1.1  Circuit Startup

          CurrentWindow    = InitialWindowSize
          FCACKOwed        = FALSE
          GrantDelayed     = FALSE
          GrantedUnits     = 0
          Repeat Window Operator

8.7.1.2  Check Buffers Available

   Can my implementation afford to grant CurrentWindow just now?

8.7.1.3  Buffers Become Available

          IF Check Buffers Available THEN
             Send FCIND( Repeat Window)
             GrantDelayed = FALSE
          ELSE
             Wait on buffers to become available (LIFO)
          ENDIF






Wells & Bartky                                                 [Page 82]
^L
RFC 1795                  Data Link Switching                 April 1995


8.7.1.4  Repeat Window Operator

          IF Check Buffers Available THEN
              Send FCIND( Repeat Window)
          ELSE
             GrantDelayed = TRUE
             Wait on buffers to become available (FIFO)
          ENDIF

8.7.1.5  Send FCIND( operator)

          GrantedUnits += CurrentWindow
          FCACKOwed     = TRUE
          Encode and Transmit FCIND piggybacked or as IFCIND

8.7.1.6  A Frame Arrives from Sender

          GrantedUnits--;
          IF frame is FCACK THEN
             IF FCACKOwed THEN
                FCACKOwed = FALSE
             ELSE
                Protocol Violation
             ENDIF
          ENDIF
          IF NOT GrantDelayed THEN
             IF GrantedUnits <= CurrentWindow THEN
                 IF FCACKOwed THEN
                   Protocol Violation
                 ELSE
                   Repeat Window Operator
                 ENDIF
             ENDIF
          ENDIF

8.7.2  Adaptive Pacing Example

   The following example illustrates a receiving implementation that
   adjusts the window size and granted units based on buffer
   availability and transport utilization.

   NOTE: This example ignores other factors which might compel the
   receiving implementation to adjust the window size (i.e., Outbound
   queue length, traffic priority, ...)

   Consider the following variables, in addition to InitialWindowSize,
   CurrentWindow and FCACKOwed:




Wells & Bartky                                                 [Page 83]
^L
RFC 1795                  Data Link Switching                 April 1995


          GrantDelayed     - Boolean
          GrantedUnits     - Outstanding Units

8.7.2.1  Circuit Startup

          CurrentWindow    = InitialWindowSize
          FCACK            = FALSE
          GrantDelayed     = FALSE
          GrantedUnits     = 0
          Repeat Window Operator

8.7.2.2  Check Buffers Available ( X)

           Can my implementation afford to grant X units just now?

8.7.2.3  Buffers Become Available

          IF Check Buffers Available THEN
             CurrentWindow--;
             Send FCIND( Decrement Window)
             GrantDelayed = FALSE
          ELSE
             Wait on buffers to become available (LIFO)
          ENDIF

8.7.2.4  Repeat Window Operator

          IF Check Buffers Available (CurrentWindow) THEN
              Send FCIND( Repeat Window)
          ELSE
             GrantDelayed = TRUE
             Wait on buffers to become available (FIFO)
          ENDIF

8.7.2.5  Increment Window Operator

          IF Check Buffers Available ( CurrentWindow + 1) THEN
              CurrentWindow++
              Send FCIND( Increment Window)
          ELSE
              Repeat Window Operator
          ENDIF

8.7.2.6  Send FCIND( operator)

          FCACKOwed     = TRUE
          GrantedUnits += CurrentWindow
          Encode and Transmit FCIND piggybacked or as IFCIND



Wells & Bartky                                                 [Page 84]
^L
RFC 1795                  Data Link Switching                 April 1995


8.7.2.7  An FCACK Arrives from Sender

          GrantedUnits--;
          IF NOT FCACKOwed THEN
             Protocol Violation
          ENDIF
          FCACKOwed = FALSE;
          IF NOT GrantDelayed THEN
             IF GrantedUnits < CurrentWindow THEN
                 Increment Window Operator
             ELSE IF GrantedUnits == CurrentWindow THEN
                 Repeat Window Operator
             END
          ENDIF

8.7.2.8  A Non-FCACK Frame Arrives from Sender

          GrantedUnits--;
          IF NOT GrantDelayed THEN
             IF FCACKOwed THEN
                IF GrantedUnits < CurrentWindow THEN
                   Protocol Violation
                END
             ELSE
                IF GrantedUnits <= CurrentWindow THEN
                   Repeat Window Operator
                ENDIF
             ENDIF
          ENDIF






















Wells & Bartky                                                 [Page 85]
^L
RFC 1795                  Data Link Switching                 April 1995


8.8  Adaptive Pacing Example Flow Diagrams

8.8.1  Example Flows from the Above Implementation

   The following diagram illustrates the use of adaptive pacing (use of
   Halve Window, and Reset operation are shown in subsequent diagrams).

   -----SENDER-----                     ----RECEIVER----
   Granted   Window                     Window   Granted
     0         2   circuit established    2         0
     2         2   <-------- FCIND(Rpt)   2         2
     1         2   FCACK-------------->   2         1
     4         3   <-------- FCIND(Inc)   3         4
     3         3   FCACK-------------->   3         3
                          +- FCIND(Rpt)   3         6
     2         3   DATA---|----------->   3         5
     1         3   DATA---|----------->   3         4
     4         3   <------+
     3         3   FCACK-------------->   3         3
     6         3   <-------- FCIND(Rpt)   3         6
     5         3   FCACK-------------->   3         5
     4         3   DATA--------------->   3         4
     3         3   DATA--------------->   3         3
                          +- FCIND(Rpt)   3         6
     2         3   DATA---|----------->   3         5
     1         3   DATA---|----------->   3         4
     0         3   DATA---|----------->   3         3
     3         3   <------+
     2         3   FCACK-------------->   3         2
     6         4   <-------- FCIND(Inc)   4         6
     5         4   FCACK-------------->   4         5
     4         4   DATA--------------->   4         4
                                        Waiting on Buffer
                          +- FCIND(Dec)   3         7
     3         4   DATA---|----------->   3         6
     2         4   DATA---|----------->   3         5
     1         4   DATA---|----------->   3         4
     0         4   DATA---|----------->   3         3
     3         3   <------+
     2         3   FCACK-------------->   3         2
                                        Waiting on Buffer
                          +- FCIND(Dec)   2         4
     1         3   DATA---|----------->   2         3
     0         3   DATA---|----------->   2         2
     2         2   <------+
     1         2   FCACK-------------->   2         1
     4         3   <-------- FCIND(Inc)   3         4
     3         3   FCACK-------------->   3         3



Wells & Bartky                                                 [Page 86]
^L
RFC 1795                  Data Link Switching                 April 1995


     6         3   <-------- FCIND(Rpt)   3         6
     5         3   FCACK-------------->   3         5
     4         3   DATA--------------->   3         4
     3         3   DATA--------------->   3         3
     6         3   <-------- FCIND(Rpt)   3         6

8.8.2  Example Halve Window Flow

   The following flow illustrates the use of the Halve Window Operator:

      -----SENDER-----                     ----RECEIVER----
      Granted   Window                     Window   Granted
        0         2   circuit established    2         0
        2         2   <-------- FCIND(Rpt)   2         2
        1         2   FCACK-------------->   2         1
        4         3   <-------- FCIND(Inc)   3         4
        3         3   FCACK-------------->   3         3
                                             Resource Shortage
        2         3   DATA--------------->   1         2
        1         3   DATA--------------->   1         1
        0         3   DATA--------------->   1         0
        1         1   <-------- FCIND(Hlv)   1         1
        0         1   FCACK-------------->   1         0

   NOTE: The Halve Window Operator could have been sent before the
   granted units fell to zero.  The implementer may make a choice based
   on the severity of the condition.

8.8.3  Example Reset Window Flows

   The following flow diagram illustrates the ResetWindow operation if
   the receiver has no FCIND outstanding.

   -----SENDER-----                     ----RECEIVER----
   Granted   Window                     Window   Granted
     0         2   circuit established    2         0
     2         2   <-------- FCIND(Rpt)   2         2
     1         2   FCACK-------------->   2         1
     4         3   <-------- FCIND(Inc)   3         4
     3         3   FCACK-------------->   3         3
                          +- FCIND(Rpt)   3         6
     2         3   DATA---|----------->   3         5
     1         3   DATA---|----------->   3         4
     4         3   <------+
     3         3   FCACK-------------->   3         3
     6         3   <-------- FCIND(Rpt)   3         6
     5         3   FCACK-------------->   3         5
                                          Resource shortage!



Wells & Bartky                                                 [Page 87]
^L
RFC 1795                  Data Link Switching                 April 1995


     0         0   <-------- FCIND(Rst)   0         5 (note still
   committed)
     0         0   IFCACK------------->   0         0
                                          Condition eases
     1         1   <-------- FCIND(Inc)   1         1
     0         1   FCACK-------------->   1         0
     2         2   <-------- FCIND(Inc)   2         2
     1         2   FCACK-------------->   3         4

   The next two flows  illustrate the Reset Window operation if the
   receiver has an outstanding FCIND.

   -----SENDER-----                     ----RECEIVER----
   Granted   Window                     Window   Granted
     0         2   circuit established    2         0
     2         2   <-------- FCIND(Rpt)   2         2
     1         2   FCACK-------------->   2         1
     4         3   <-------- FCIND(Inc)   3         4
     3         3   FCACK-------------->   3         3
                          +- FCIND(Rpt)   3         6
     2         3   DATA---|----------->   3         5
                          |               Resource shortage!
                          |+-FCIND(Rst)   0         5
     1         3   DATA---||---------->   0         4
     4         3   <------+|
     3         3   FCACK---+---------->   0         3 (Not IFCACK!)
     2         3   DATA----|---------->   0         2
     0         0   <-------+
     0         0   IFCACK------------->   0         0
                                          Condition eases
     1         1   <-------- FCIND(Inc)   1         1
     0         1   FCACK-------------->   1         0
     2         2   <-------- FCIND(Inc)   2         2
     1         2   FCACK-------------->   3         4

   -----SENDER-----                     ----RECEIVER----
   Granted   Window                     Window   Granted
     0         2   circuit established    2         0
     2         2   <-------- FCIND(Rpt)   2         2
     1         2   FCACK-------------->   2         1
     4         3   <-------- FCIND(Inc)   3         4
     3         3   FCACK-------------->   3         3
                          +- FCIND(Rpt)   3         6
     2         3   DATA---|----------->   3         5
                          |               Resource shortage!
                          |+-FCIND(Rst)   0         5
     1         3   DATA---||---------->   0         4
     4         3   <------+|



Wells & Bartky                                                 [Page 88]
^L
RFC 1795                  Data Link Switching                 April 1995


     0         0   <-------+
     0         0   IFCACK------------->   0         0
                                          Condition eases
     1         1   <-------- FCIND(Inc)   1         1
     0         1   FCACK-------------->   1         0
     2         2   <-------- FCIND(Inc)   2         2
     1         2   FCACK-------------->   3         4

8.9  Other Considerations

8.9.1  Protocol Violations

   The following events are considered protocol violations:

   1. Sender exceeds granted units or does not acknowledge FCIND on
      first frame after its receipt (the receiver can not discern the
      difference between the two).

   2. Receiver does not follow a Reset Window Operator with an Increment
      Window Operator.

   3. Receiver has two unacknowledged FCINDs ( other than Reset Window)
      outstanding.

   4. Receiver sends Decrement Window Operator with a window size of one.

   5. Receiver attempts to increment the window size beyond 0xFFFF.

   Actions taken in response to protocol violations are left to the
   implementation of the node which discovers the violation.  If an
   implementation chooses to take down the circuit on which the
   violation occurred, HALT_DL is the appropriate action.

Acknowledgments

   Original RFC 1434 Authors:

      Roy C. Dixon, IBM
      David M. Kushi, IBM

   Chair of APPN Implementers Workshop Data Link Switching Related
   Interest Group:

      Louise Herndon Wells, Internetworking Technology Institute







Wells & Bartky                                                 [Page 89]
^L
RFC 1795                  Data Link Switching                 April 1995


   Working Group Chairs (and significant contributors to this document):

      Connect/Disconnect (State Machines): Steve Klein, IBM
      Capabilities Exchange: Wayne Clark, Cisco Systems
      Flow Control (Adaptive Pacing): Shannon Nix, Metaplex
      Priority/Class of Service: Gene Cox, IBM

   Other significant contributors:

      Peter Gayek, IBM
      Paul Brittain, Data Connection Limited

References

   1) ISO 8802-2/IEEE Std 802.2 International Standard, Information
      Processing Systems, Local Area Networks, Part 2: Logical Link
      Control, December 31, 1989.

   2) IBM LAN Technical Reference IEEE 802.2 and NETBIOS Application
      Program Interfaces SC30-3587-00, December 1993.

   3) ISO/IEC DIS 10038 DAM 2, MAC Bridging, Source Routing Supplement,
      December 1991.

   4) ISO 8802-2/IEEE Std 802.1D International Standard, Information
      Processing Systems, Local Area Networks, Part 2: MAC layer
      Bridging.
























Wells & Bartky                                                 [Page 90]
^L
RFC 1795                  Data Link Switching                 April 1995


Security Considerations

   Security issues are not discussed in this memo.

Chair's Address

   Louise Wells
   Internetwork Technology Institute
   2021 Stratford Dr.
   Milpitas, CA  95035

   EMail: lhwells@cup.portal.com

Editor's Address

   Alan K. Bartky
   Manager of Technology
   Sync Research Inc.
   7 Studebaker
   Irvine, CA 91728-2013

   Phone: 1-714-588-2070
   EMail: alan@sync.com


   Note: Any questions or comments relative to the contents of this RFC
   should be sent to the following Internet address:
   aiw-dlsw@networking.raleigh.ibm.com.

   This address will be used to coordinate the handling of responses.

   NOTE 1:  This is a widely subscribed mailing list and messages sent to
            this address will be sent to all members of the DLSw mailing
            list.  For specific questions relating to subscribing to the
            AIW and any of it's working groups send email to:
            appn@vnet.ibm.com

            Information regarding all of the AIW working groups and the
            work they are producing can be obtained by copying, via
            anonymous ftp, the file aiwinfo.psbin or aiwinfo.txt from the
            Internet host networking.raleigh.ibm.com, located in
            directory aiw.

   NOTE 2: These mailing lists and addresses are subject to change.







Wells & Bartky                                                 [Page 91]
^L