1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
|
Network Working Group P. Phaal
Request for Comments: 3176 S. Panchen
Category: Informational N. McKee
InMon Corp.
September 2001
InMon Corporation's sFlow: A Method for Monitoring Traffic in
Switched and Routed Networks
Status of this Memo
This memo provides information for the Internet community. It does
not specify an Internet standard of any kind. Distribution of this
memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2001). All Rights Reserved.
Abstract
This memo defines InMon Coporation's sFlow system. sFlow is a
technology for monitoring traffic in data networks containing
switches and routers. In particular, it defines the sampling
mechanisms implemented in an sFlow Agent for monitoring traffic, the
sFlow MIB for controlling the sFlow Agent, and the format of sample
data used by the sFlow Agent when forwarding data to a central data
collector.
Table of Contents
1. Overview ..................................................... 2
2. Sampling Mechanisms .......................................... 2
2.1 Sampling of Switched Flows ............................... 3
2.1.1 Distributed Switching .............................. 4
2.1.2 Random Number Generation ........................... 4
2.2 Sampling of Network Interface Statistics ................. 4
3. sFlow MIB .................................................... 5
3.1 The SNMP Management Framework ............................ 5
3.2 Definitions .............................................. 6
4. sFlow Datagram Format ........................................ 14
5. Security Considerations ...................................... 25
5.1 Control .................................................. 26
5.2 Transport ................................................ 26
5.3 Confidentiality .......................................... 26
6. References ................................................... 27
7. Authors' Addresses ........................................... 29
Phaal, et al. Informational [Page 1]
^L
RFC 3176 InMon Corporation's sFlow September 2001
8. Intellectual Property Statement .............................. 30
9. Full Copyright Statement ..................................... 31
1. Overview
sFlow is a technology for monitoring traffic in data networks
containing switches and routers. In particular, it defines the
sampling mechanisms implemented in an sFlow Agent for monitoring
traffic, the sFlow MIB for controlling the sFlow Agent, and the
format of sample data used by the sFlow Agent when forwarding data to
a central data collector.
The architecture and sampling techniques used in the sFlow monitoring
system are designed to provide continuous site-wide (and network-
wide) traffic monitoring for high speed switched and routed networks.
The design specifically addresses issues associated with:
o Accurately monitoring network traffic at Gigabit speeds and higher.
o Scaling to manage tens of thousands of agents from a single point.
o Extremely low cost agent implementation.
The sFlow monitoring system consists of an sFlow Agent (embedded in a
switch or router or in a stand alone probe) and a central data
collector, or sFlow Analyzer.
The sFlow Agent uses sampling technology to capture traffic
statistics from the device it is monitoring. sFlow Datagrams are
used to immediately forward the sampled traffic statistics to an
sFlow Analyzer for analysis.
This document describes the sampling mechanisms used by the sFlow
Agent, the SFLOW MIB used by the sFlow Analyzer to control the sFlow
Agent, and the sFlow Datagram Format used by the sFlow Agent to send
traffic data to the sFlow Analyzer.
2. Sampling Mechanisms
The sFlow Agent uses two forms of sampling: statistical packet-based
sampling of switched flows, and time-based sampling of network
interface statistics.
Phaal, et al. Informational [Page 2]
^L
RFC 3176 InMon Corporation's sFlow September 2001
2.1 Sampling of Switched Flows
A flow is defined as all the packets that are received on one
interface, enter the Switching/Routing Module and are sent to another
interface. In the case of a one-armed router, the source and
destination interface could be the same. In the case of a broadcast
or multicast packet there may be multiple destination interfaces.
The sampling mechanism must ensure that any packet involved in a flow
has an equal chance of being sampled, irrespective of the flow to
which it belongs.
Sampling flows is accomplished as follows: When a packet arrives on
an interface, a filtering decision is made that determines whether
the packet should be dropped. If the packet is not filtered a
destination interface is assigned by the switching/routing function.
At this point a decision is made on whether or not to sample the
packet. The mechanism involves a counter that is decremented with
each packet. When the counter reaches zero a sample is taken.
Whether or not a sample is taken, the counter Total_Packets is
incremented. Total_Packets is a count of all the packets that could
have been sampled.
Taking a sample involves either copying the packet's header, or
extracting features from the packet (see sFlow Datagram Format for a
description of the different forms of sample). Every time a sample
is taken, the counter Total_Samples, is incremented. Total_Samples
is a count of the number of samples generated. Samples are sent by
the sampling entity to the sFlow Agent for processing. The sample
includes the packet information, and the values of the Total_Packets
and Total_Samples counters.
When a sample is taken, the counter indicating how many packets to
skip before taking the next sample should be reset. The value of the
counter should be set to a random integer where the sequence of
random integers used over time should be such that
(1) Total_Packets/Total_Samples = Rate
An alternative strategy for packet sampling is to generate a random
number for each packet, compare the random number to a preset
threshold and take a sample whenever the random number is smaller
than the threshold value. Calculation of an appropriate threshold
value depends on the characteristics of the random number generator,
however, the resulting sample stream must still satisfy (1).
Phaal, et al. Informational [Page 3]
^L
RFC 3176 InMon Corporation's sFlow September 2001
2.1.1 Distributed Switching
The SFLOW MIB permits separate sampling entities to be associated
with different physical or logical elements of the switch (such as
interfaces, backplanes or VLANs). Each sampling engine has its own
independent state (i.e., Total_Packets, Total_Samples, Skip and
Rate), and forwards its own sample messages to the sFlow Agent. The
sFlow Agent is responsible for packaging the samples into datagrams
for transmission to an sFlow Analyzer.
2.1.2 Random Number Generation
The essential property of the random number generator is that the
mean value of the numbers it generates converges to the required
sampling rate.
A uniform distribution random number generator is very effective.
The range of skip counts (the variance) does not significantly affect
results; variation of +-10% of the mean value is sufficient.
The random number generator must ensure that all numbers in the range
between its maximum and minimum values of the distribution are
possible; a random number generator only capable of generating even
numbers, or numbers with any common divisor is unsuitable.
A new skip value is only required every time a sample is taken.
2.2 Sampling of Network Interface Statistics
The objective of the counter sampling is to efficiently, periodically
poll each data source on the device and extract key statistics.
For efficiency and scalability reasons, the sFlow System implements
counter polling in the sFlow Agent. A maximum polling interval is
assigned to the agent, but the agent is free to schedule polling in
order maximize internal efficiency.
Flow sampling and counter sampling are designed as part of an
integrated system. Both types of samples are combined in sFlow
Datagrams. Since flow sampling will cause a steady, but random,
stream of datagrams to be sent to the sFlow Analyzer, counter samples
may be taken opportunistically in order to fill these datagrams.
One strategy for counter sampling has the sFlow Agent keep a list of
counter sources being sampled. When a flow sample is generated the
sFlow Agent examines the list and adds counters to the sample
datagram, least recently sampled first. Counters are only added to
the datagram if the sources are within a short period, 5 seconds say,
Phaal, et al. Informational [Page 4]
^L
RFC 3176 InMon Corporation's sFlow September 2001
of failing to meet the required sampling interval (see
sFlowCounterSamplingInterval in SFLOW MIB). Whenever a counter
source's statistics are added to a sample datagram, the time the
counter source was last sampled is updated and the counter source is
placed at the end of the list. Periodically, say every second, the
sFlow Agent examines the list of counter sources and sends any
counters that need to be sent to meet the sampling interval
requirement.
Alternatively, if the agent regularly schedules counter sampling,
then it should schedule each counter source at a different start time
(preferably randomly) so that counter sampling is not synchronized
within an agent or between agents.
3. sFlow MIB
The sFlow MIB defines a control interface for an sFlow Agent. This
interface provides a standard mechanism for remotely controlling and
configuring an sFlow Agent.
3.1 The SNMP Management Framework
The SNMP Management Framework presently consists of five major
components:
o An overall architecture, described in RFC 2571 [2].
o Mechanisms for describing and naming objects and events for the
purpose of management. The first version of this Structure of
Management Information (SMI) is called SMIv1 and described in STD
16,
RFC 1155 [3], STD 16, RFC 1212 [4] and RFC 1215 [5]. The second
version, called SMIv2, is described in STD 58, RFC 2578 [6], STD
58, RFC 2579 [7] and STD 58, RFC 2580 [8].
o Message protocols for transferring management information. The
first version of the SNMP message protocol is called SNMPv1 and
described in STD 15, RFC 1157 [9]. A second version of the SNMP
message protocol, which is not an Internet standards track
protocol, is called SNMPv2c and described in RFC 1901 [10] and RFC
1906 [11]. The third version of the message protocol is called
SNMPv3 and described in RFC 1906 [11], RFC 2572 [12] and RFC 2574
[13].
Phaal, et al. Informational [Page 5]
^L
RFC 3176 InMon Corporation's sFlow September 2001
o Protocol operations for accessing management information. The
first set of protocol operations and associated PDU formats is
described in STD 15, RFC 1157 [9]. A second set of protocol
operations and associated PDU formats is described in RFC 1905
[14].
o A set of fundamental applications described in RFC 2573 [15] and
the view-based access control mechanism described in RFC 2575
[16].
A more detailed introduction to the current SNMP Management Framework
can be found in RFC 2570 [17].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the mechanisms defined in the SMI.
This memo specifies a MIB module that is compliant to the SMIv2. A
MIB conforming to the SMIv1 can be produced through the appropriate
translations. The resulting translated MIB must be semantically
equivalent, except where objects or events are omitted because no
translation is possible (use of Counter64). Some machine readable
information in SMIv2 will be converted into textual descriptions in
SMIv1 during the translation process. However, this loss of machine
readable information is not considered to change the semantics of the
MIB.
3.2 Definitions
SFLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises
FROM SNMPv2-SMI
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
OwnerString
FROM RMON-MIB
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF;
sFlowMIB MODULE-IDENTITY
LAST-UPDATED "200105150000Z" -- May 15, 2001
ORGANIZATION "InMon Corp."
CONTACT-INFO
Phaal, et al. Informational [Page 6]
^L
RFC 3176 InMon Corporation's sFlow September 2001
"Peter Phaal
InMon Corp.
http://www.inmon.com/
Tel: +1-415-661-6343
Email: peter_phaal@inmon.com"
DESCRIPTION
"The MIB module for managing the generation and transportation
of sFlow data records."
--
-- Revision History
--
REVISION "200105150000Z" -- May 15, 2001
DESCRIPTION
"Version 1.2
Brings MIB into SMI v2 compliance."
REVISION "200105010000Z" -- May 1, 2001
DESCRIPTION
"Version 1.1
Adds sFlowDatagramVersion."
::= { enterprises 4300 1 }
sFlowAgent OBJECT IDENTIFIER ::= { sFlowMIB 1 }
sFlowVersion OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uniquely identifies the version and implementation of this MIB.
The version string must have the following structure:
<MIB Version>;<Organization>;<Software Revision>
where:
<MIB Version> must be '1.2', the version of this MIB.
<Organization> the name of the organization responsible
for the agent implementation.
<Revision> the specific software build of this agent.
As an example, the string '1.2;InMon Corp.;2.1.1' indicates
that this agent implements version '1.2' of the SFLOW MIB, that
it was developed by 'InMon Corp.' and that the software build
is '2.1.1'.
The MIB Version will change with each revision of the SFLOW
Phaal, et al. Informational [Page 7]
^L
RFC 3176 InMon Corporation's sFlow September 2001
MIB.
Management entities must check the MIB Version and not attempt
to manage agents with MIB Versions greater than that for which
they were designed.
Note: The sFlow Datagram Format has an independent version
number which may change independently from <MIB Version>.
<MIB Version> applies to the structure and semantics of
the SFLOW MIB only."
DEFVAL { "1.2;;" }
::= { sFlowAgent 1 }
sFlowAgentAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address type of the address associated with this agent.
Only ipv4 and ipv6 types are supported."
::= { sFlowAgent 2 }
sFlowAgentAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address associated with this agent. In the case of a
multi-homed agent, this should be the loopback address of the
agent. The sFlowAgent address must provide SNMP connectivity
to the agent. The address should be an invariant that does not
change as interfaces are reconfigured, enabled, disabled,
added or removed. A manager should be able to use the
sFlowAgentAddress as a unique key that will identify this
agent over extended periods of time so that a history can
be maintained."
::= { sFlowAgent 3 }
sFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF SFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the sFlow samplers within a device."
::= { sFlowAgent 4 }
sFlowEntry OBJECT-TYPE
SYNTAX SFlowEntry
Phaal, et al. Informational [Page 8]
^L
RFC 3176 InMon Corporation's sFlow September 2001
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of an sFlow sampler."
INDEX { sFlowDataSource }
::= { sFlowTable 1 }
SFlowEntry ::= SEQUENCE {
sFlowDataSource OBJECT IDENTIFIER,
sFlowOwner OwnerString,
sFlowTimeout Integer32,
sFlowPacketSamplingRate Integer32,
sFlowCounterSamplingInterval Integer32,
sFlowMaximumHeaderSize Integer32,
sFlowMaximumDatagramSize Integer32,
sFlowCollectorAddressType InetAddressType,
sFlowCollectorAddress InetAddress,
sFlowCollectorPort Integer32,
sFlowDatagramVersion Integer32
}
sFlowDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the source of the data for the sFlow sampler.
The following data source types are currently defined:
- ifIndex.<I>
DataSources of this traditional form are called 'port-based'.
Ideally the sampling entity will perform sampling on all flows
originating from or destined to the specified interface.
However, if the switch architecture only permits input or
output sampling then the sampling agent is permitted to only
sample input flows input or output flows. Each packet must
only be considered once for sampling, irrespective of the
number of ports it will be forwarded to.
Note: Port 0 is used to indicate that all ports on the device
are represented by a single data source.
- sFlowPacketSamplingRate applies to all ports on the
device capable of packet sampling.
- sFlowCounterSamplingInterval applies to all ports.
- smonVlanDataSource.<V>
A dataSource of this form refers to a 'Packet-based VLAN'
and is called a 'VLAN-based' dataSource. <V> is the VLAN
Phaal, et al. Informational [Page 9]
^L
RFC 3176 InMon Corporation's sFlow September 2001
ID as defined by the IEEE 802.1Q standard. The
value is between 1 and 4094 inclusive, and it represents
an 802.1Q VLAN-ID with global scope within a given
bridged domain.
Sampling is performed on all packets received that are part
of the specified VLAN (no matter which port they arrived on).
Each packet will only be considered once for sampling,
irrespective of the number of ports it will be forwarded to.
- entPhysicalEntry.<N>
A dataSource of this form refers to a physical entity within
the agent (e.g., entPhysicalClass = backplane(4)) and is called
an 'entity-based' dataSource.
Sampling is performed on all packets entering the resource (e.g.
If the backplane is being sampled, all packets transmitted onto
the backplane will be considered as single candidates for
sampling irrespective of the number of ports they ultimately
reach).
Note: Since each DataSource operates independently, a packet
that crosses multiple DataSources may generate multiple
flow records."
::= { sFlowEntry 1 }
sFlowOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity making use of this sFlow sampler. The empty string
indicates that the sFlow sampler is currently unclaimed.
An entity wishing to claim an sFlow sampler must make sure
that the sampler is unclaimed before trying to claim it.
The sampler is claimed by setting the owner string to identify
the entity claiming the sampler. The sampler must be claimed
before any changes can be made to other sampler objects.
In order to avoid a race condition, the entity taking control
of the sampler must set both the owner and a value for
sFlowTimeout in the same SNMP set request.
When a management entity is finished using the sampler,
it should set its value back to unclaimed. The agent
must restore all other entities this row to their
default values when the owner is set to unclaimed.
This mechanism provides no enforcement and relies on the
cooperation of management entities in order to ensure that
Phaal, et al. Informational [Page 10]
^L
RFC 3176 InMon Corporation's sFlow September 2001
competition for a sampler is fairly resolved."
DEFVAL { "" }
::= { sFlowEntry 2 }
sFlowTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) remaining before the sampler is released
and stops sampling. When set, the owner establishes control
for the specified period. When read, the remaining time in the
interval is returned.
A management entity wanting to maintain control of the sampler
is responsible for setting a new value before the old one
expires.
When the interval expires, the agent is responsible for
restoring all other entities in this row to their default
values."
DEFVAL { 0 }
::= { sFlowEntry 3 }
sFlowPacketSamplingRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The statistical sampling rate for packet sampling from this
source.
Set to N to sample 1/Nth of the packets in the monitored flows.
An agent should choose its own algorithm introduce variance
into the sampling so that exactly every Nth packet is not
counted. A sampling rate of 1 counts all packets. A sampling
rate of 0 disables sampling.
The agent is permitted to have minimum and maximum allowable
values for the sampling rate. A minimum rate lets the agent
designer set an upper bound on the overhead associated with
sampling, and a maximum rate may be the result of hardware
restrictions (such as counter size). In addition not all values
between the maximum and minimum may be realizable as the
sampling rate (again because of implementation considerations).
When the sampling rate is set the agent is free to adjust the
value so that it lies between the maximum and minimum values
Phaal, et al. Informational [Page 11]
^L
RFC 3176 InMon Corporation's sFlow September 2001
and has the closest achievable value.
When read, the agent must return the actual sampling rate it
will be using (after the adjustments previously described). The
sampling algorithm must converge so that over time the number
of packets sampled approaches 1/Nth of the total number of
packets in the monitored flows."
DEFVAL { 0 }
::= { sFlowEntry 4 }
sFlowCounterSamplingInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of seconds between successive samples of the
counters associated with this data source. A sampling interval
of 0 disables counter sampling."
DEFVAL { 0 }
::= { sFlowEntry 5 }
sFlowMaximumHeaderSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of bytes that should be copied from a
sampled packet. The agent may have an internal maximum and
minimum permissible sizes. If an attempt is made to set this
value outside the permissible range then the agent should
adjust the value to the closest permissible value."
DEFVAL { 128 }
::= { sFlowEntry 6 }
sFlowMaximumDatagramSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of data bytes that can be sent in a single
sample datagram. The manager should set this value to avoid
fragmentation of the sFlow datagrams."
DEFVAL { 1400 }
::= { sFlowEntry 7 }
sFlowCollectorAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
Phaal, et al. Informational [Page 12]
^L
RFC 3176 InMon Corporation's sFlow September 2001
STATUS current
DESCRIPTION
"The type of sFlowCollectorAddress."
DEFVAL { ipv4 }
::= { sFlowEntry 8 }
sFlowCollectorAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the sFlow collector.
If set to 0.0.0.0 all sampling is disabled."
DEFVAL { "0.0.0.0" }
::= { sFlowEntry 9 }
sFlowCollectorPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination port for sFlow datagrams."
DEFVAL { 6343 }
::= { sFlowEntry 10 }
sFlowDatagramVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The version of sFlow datagrams that should be sent.
When set to a value not support by the agent, the agent should
adjust the value to the highest supported value less than the
requested value, or return an error if no such values exist."
DEFVAL { 4 }
::= { sFlowEntry 11 }
--
-- Compliance Statements
--
sFlowMIBConformance OBJECT IDENTIFIER ::= { sFlowMIB 2 }
sFlowMIBGroups OBJECT IDENTIFIER ::= { sFlowMIBConformance 1 }
sFlowMIBCompliances OBJECT IDENTIFIER ::= { sFlowMIBConformance 2 }
sFlowCompliance MODULE-COMPLIANCE
STATUS current
Phaal, et al. Informational [Page 13]
^L
RFC 3176 InMon Corporation's sFlow September 2001
DESCRIPTION
"Compliance statements for the sFlow Agent."
MODULE -- this module
MANDATORY-GROUPS { sFlowAgentGroup }
OBJECT sFlowAgentAddressType
SYNTAX InetAddressType { ipv4(1) }
DESCRIPTION
"Agents need only support ipv4."
OBJECT sFlowCollectorAddressType
SYNTAX InetAddressType { ipv4(1) }
DESCRIPTION
"Agents need only support ipv4."
::= { sFlowMIBCompliances 1 }
sFlowAgentGroup OBJECT-GROUP
OBJECTS { sFlowVersion, sFlowAgentAddressType, sFlowAgentAddress,
sFlowDataSource, sFlowOwner, sFlowTimeout,
sFlowPacketSamplingRate, sFlowCounterSamplingInterval,
sFlowMaximumHeaderSize, sFlowMaximumDatagramSize,
sFlowCollectorAddressType, sFlowCollectorAddress,
sFlowCollectorPort, sFlowDatagramVersion }
STATUS current
DESCRIPTION
"A collection of objects for managing the generation and
transportation of sFlow data records."
::= { sFlowMIBGroups 1 }
END
The sFlow MIB references definitions from a number of existing RFCs
[18], [19], [20] and [21].
4. sFlow Datagram Format
The sFlow datagram format specifies a standard format for the sFlow
Agent to send sampled data to a remote data collector.
The format of the sFlow datagram is specified using the XDR standard
[1]. XDR is more compact than ASN.1 and simpler for the sFlow Agent
to encode and the sFlow Analyzer to decode.
Samples are sent as UDP packets to the host and port specified in the
SFLOW MIB. The lack of reliability in the UDP transport mechanism
does not significantly affect the accuracy of the measurements
obtained from an sFlow Agent.
Phaal, et al. Informational [Page 14]
^L
RFC 3176 InMon Corporation's sFlow September 2001
o If counter samples are lost then new values will be sent during
the next polling interval. The chance of an undetected counter
wrap is negligible. The sFlow datagram specifies 64 bit octet
counters, and with typical counter polling intervals between 20 to
120 seconds, the chance of a long enough sequence of sFlow
datagrams being lost to hide a counter wrap is very small.
o The net effect of lost flow samples is a slight reduction in the
effective sampling rate.
The use of UDP reduces the amount of memory required to buffer data.
UDP also provides a robust means of delivering timely traffic
information during periods of intense traffic (such as a denial of
service attack). UDP is more robust than a reliable transport
mechanism because under overload the only effect on overall system
performance is a slight increase in transmission delay and a greater
number of lost packets, neither of which has a significant effect on
an sFlow-based monitoring system. If a reliable transport mechanism
were used then an overload would introduce long transmission delays
and require large amounts of buffer memory on the agent.
While the sFlow Datagram structure permits multiple samples to be
included in each datagram, the sampling agent must not wait for a
buffer to fill with samples before sending the sample datagram.
sFlow sampling is intended to provide timely information on traffic.
The agent may at most delay a sample by 1 second before it is
required to send the datagram.
The agent should try to piggyback counter samples on the datagram
stream resulting from flow sampling. Before sending out a datagram
the remaining space in the buffer can be filled with counter samples.
The agent has discretion in the timing of its counter polling, the
specified counter sampling intervals sFlowCounterSamplingInterval is
a maximum, so the agent is free to sample counters early if it has
space in a datagram. If counters must be sent in order to satisfy
the maximum sampling interval then a datagram must be sent containing
the outstanding counters.
The following is the XDR description of an sFlow Datagram:
/* sFlow Datagram Version 4 */
/* Revision History
- version 4 adds support BGP communities
- version 3 adds support for extended_url information
*/
/* sFlow Sample types */
Phaal, et al. Informational [Page 15]
^L
RFC 3176 InMon Corporation's sFlow September 2001
/* Address Types */
typedef opaque ip_v4[4];
typedef opaque ip_v6[16];
enum address_type {
IP_V4 = 1,
IP_V6 = 2
}
union address (address_type type) {
case IP_V4:
ip_v4;
case IP_V6:
ip_v6;
}
/* Packet header data */
const MAX_HEADER_SIZE = 256; /* The maximum sampled header size. */
/* The header protocol describes the format of the sampled header */
enum header_protocol {
ETHERNET-ISO8023 = 1,
ISO88024-TOKENBUS = 2,
ISO88025-TOKENRING = 3,
FDDI = 4,
FRAME-RELAY = 5,
X25 = 6,
PPP = 7,
SMDS = 8,
AAL5 = 9,
AAL5-IP = 10, /* e.g., Cisco AAL5 mux */
IPv4 = 11,
IPv6 = 12,
MPLS = 13
}
struct sampled_header {
header_protocol protocol; /* Format of sampled header */
unsigned int frame_length; /* Original length of packet before
sampling */
opaque header<MAX_HEADER_SIZE>; /* Header bytes */
}
/* Packet IP version 4 data */
struct sampled_ipv4 {
Phaal, et al. Informational [Page 16]
^L
RFC 3176 InMon Corporation's sFlow September 2001
unsigned int length; /* The length of the IP packet excluding
lower layer encapsulations */
unsigned int protocol; /* IP Protocol type
(for example, TCP = 6, UDP = 17) */
ip_v4 src_ip; /* Source IP Address */
ip_v4 dst_ip; /* Destination IP Address */
unsigned int src_port; /* TCP/UDP source port number or
equivalent */
unsigned int dst_port; /* TCP/UDP destination port number or
equivalent */
unsigned int tcp_flags; /* TCP flags */
unsigned int tos; /* IP type of service */
}
/* Packet IP version 6 data */
struct sampled_ipv6 {
unsigned int length; /* The length of the IP packet excluding
lower layer encapsulations */
unsigned int protocol; /* IP next header
(for example, TCP = 6, UDP = 17) */
ip_v6 src_ip; /* Source IP Address */
ip_v6 dst_ip; /* Destination IP Address */
unsigned int src_port; /* TCP/UDP source port number or
equivalent */
unsigned int dst_port; /* TCP/UDP destination port number or
equivalent */
unsigned int tcp_flags; /* TCP flags */
unsigned int priority; /* IP priority */
}
/* Packet data */
enum packet_information_type {
HEADER = 1, /* Packet headers are sampled */
IPV4 = 2, /* IP version 4 data */
IPV6 = 3 /* IP version 6 data */
}
union packet_data_type (packet_information_type type) {
case HEADER:
sampled_header header;
case IPV4:
sampled_ipv4 ipv4;
case IPV6:
sampled_ipv6 ipv6;
}
Phaal, et al. Informational [Page 17]
^L
RFC 3176 InMon Corporation's sFlow September 2001
/* Extended data types */
/* Extended switch data */
struct extended_switch {
unsigned int src_vlan; /* The 802.1Q VLAN id of incoming frame */
unsigned int src_priority; /* The 802.1p priority of incoming
frame */
unsigned int dst_vlan; /* The 802.1Q VLAN id of outgoing frame */
unsigned int dst_priority; /* The 802.1p priority of outgoing
frame */
}
/* Extended router data */
struct extended_router {
address nexthop; /* IP address of next hop router */
unsigned int src_mask; /* Source address prefix mask bits */
unsigned int dst_mask; /* Destination address prefix mask bits */
}
/* Extended gateway data */
enum as_path_segment_type {
AS_SET = 1, /* Unordered set of ASs */
AS_SEQUENCE = 2 /* Ordered set of ASs */
}
union as_path_type (as_path_segment_type) {
case AS_SET:
unsigned int as_set<>;
case AS_SEQUENCE:
unsigned int as_sequence<>;
}
struct extended_gateway {
unsigned int as; /* Autonomous system number of router */
unsigned int src_as; /* Autonomous system number of source */
unsigned int src_peer_as; /* Autonomous system number of source
peer */
as_path_type dst_as_path<>; /* Autonomous system path to the
destination */
unsigned int communities<>; /* Communities associated with this
route */
unsigned int localpref; /* LocalPref associated with this
route */
}
Phaal, et al. Informational [Page 18]
^L
RFC 3176 InMon Corporation's sFlow September 2001
/* Extended user data */
struct extended_user {
string src_user<>; /* User ID associated with packet
source */
string dst_user<>; /* User ID associated with packet
destination */
}
/* Extended URL data */
enum url_direction {
src = 1, /* URL is associated with source
address */
dst = 2 /* URL is associated with destination
address */
}
struct extended_url {
url_direction direction; /* URL associated with packet source */
string url<>; /* URL associated with the packet flow */
}
/* Extended data */
enum extended_information_type {
SWITCH = 1, /* Extended switch information */
ROUTER = 2, /* Extended router information */
GATEWAY = 3, /* Extended gateway router information */
USER = 4, /* Extended TACACS/RADIUS user information */
URL = 5 /* Extended URL information */
}
union extended_data_type (extended_information_type type) {
case SWITCH:
extended_switch switch;
case ROUTER:
extended_router router;
case GATEWAY:
extended_gateway gateway;
case USER:
extended_user user;
case URL:
extended_url url;
}
/* Format of a single flow sample */
Phaal, et al. Informational [Page 19]
^L
RFC 3176 InMon Corporation's sFlow September 2001
struct flow_sample {
unsigned int sequence_number; /* Incremented with each flow sample
generated by this source_id */
unsigned int source_id; /* sFlowDataSource encoded as follows:
The most significant byte of the
source_id is used to indicate the
type of sFlowDataSource
(0 = ifIndex,
1 = smonVlanDataSource,
2 = entPhysicalEntry) and the
lower three bytes contain the
relevant index value.*/
unsigned int sampling_rate; /* sFlowPacketSamplingRate */
unsigned int sample_pool; /* Total number of packets that could
have been sampled (i.e., packets
skipped by sampling process + total
number of samples) */
unsigned int drops; /* Number times a packet was dropped
due to lack of resources */
unsigned int input; /* SNMP ifIndex of input interface.
0 if interface is not known. */
unsigned int output; /* SNMP ifIndex of output interface,
0 if interface is not known.
Set most significant bit to
indicate multiple destination
interfaces (i.e., in case of
broadcast or multicast)
and set lower order bits to
indicate number of destination
interfaces.
Examples:
0x00000002 indicates ifIndex =
2
0x00000000 ifIndex unknown.
0x80000007 indicates a packet
sent to 7
interfaces.
0x80000000 indicates a packet
sent to an unknown
number of interfaces
greater than 1. */
packet_data_type packet_data; /* Information about sampled
packet */
extended_data_type extended_data<>; /* Extended flow information */
}
Phaal, et al. Informational [Page 20]
^L
RFC 3176 InMon Corporation's sFlow September 2001
/* Counter types */
/* Generic interface counters - see RFC 2233 */
struct if_counters {
unsigned int ifIndex;
unsigned int ifType;
unsigned hyper ifSpeed;
unsigned int ifDirection; /* derived from MAU MIB (RFC 2668)
0 = unknown, 1=full-duplex,
2=half-duplex, 3 = in, 4=out */
unsigned int ifStatus; /* bit field with the following bits
assigned
bit 0 = ifAdminStatus
(0 = down, 1 = up)
bit 1 = ifOperStatus
(0 = down, 1 = up) */
unsigned hyper ifInOctets;
unsigned int ifInUcastPkts;
unsigned int ifInMulticastPkts;
unsigned int ifInBroadcastPkts;
unsigned int ifInDiscards;
unsigned int ifInErrors;
unsigned int ifInUnknownProtos;
unsigned hyper ifOutOctets;
unsigned int ifOutUcastPkts;
unsigned int ifOutMulticastPkts;
unsigned int ifOutBroadcastPkts;
unsigned int ifOutDiscards;
unsigned int ifOutErrors;
unsigned int ifPromiscuousMode;
}
/* Ethernet interface counters - see RFC 2358 */
struct ethernet_counters {
if_counters generic;
unsigned int dot3StatsAlignmentErrors;
unsigned int dot3StatsFCSErrors;
unsigned int dot3StatsSingleCollisionFrames;
unsigned int dot3StatsMultipleCollisionFrames;
unsigned int dot3StatsSQETestErrors;
unsigned int dot3StatsDeferredTransmissions;
unsigned int dot3StatsLateCollisions;
unsigned int dot3StatsExcessiveCollisions;
unsigned int dot3StatsInternalMacTransmitErrors;
unsigned int dot3StatsCarrierSenseErrors;
unsigned int dot3StatsFrameTooLongs;
Phaal, et al. Informational [Page 21]
^L
RFC 3176 InMon Corporation's sFlow September 2001
unsigned int dot3StatsInternalMacReceiveErrors;
unsigned int dot3StatsSymbolErrors;
}
/* FDDI interface counters - see RFC 1512 */
struct fddi_counters {
if_counters generic;
}
/* Token ring counters - see RFC 1748 */
struct tokenring_counters {
if_counters generic;
unsigned int dot5StatsLineErrors;
unsigned int dot5StatsBurstErrors;
unsigned int dot5StatsACErrors;
unsigned int dot5StatsAbortTransErrors;
unsigned int dot5StatsInternalErrors;
unsigned int dot5StatsLostFrameErrors;
unsigned int dot5StatsReceiveCongestions;
unsigned int dot5StatsFrameCopiedErrors;
unsigned int dot5StatsTokenErrors;
unsigned int dot5StatsSoftErrors;
unsigned int dot5StatsHardErrors;
unsigned int dot5StatsSignalLoss;
unsigned int dot5StatsTransmitBeacons;
unsigned int dot5StatsRecoverys;
unsigned int dot5StatsLobeWires;
unsigned int dot5StatsRemoves;
unsigned int dot5StatsSingles;
unsigned int dot5StatsFreqErrors;
}
/* 100 BaseVG interface counters - see RFC 2020 */
struct vg_counters {
if_counters generic;
unsigned int dot12InHighPriorityFrames;
unsigned hyper dot12InHighPriorityOctets;
unsigned int dot12InNormPriorityFrames;
unsigned hyper dot12InNormPriorityOctets;
unsigned int dot12InIPMErrors;
unsigned int dot12InOversizeFrameErrors;
unsigned int dot12InDataErrors;
unsigned int dot12InNullAddressedFrames;
unsigned int dot12OutHighPriorityFrames;
unsigned hyper dot12OutHighPriorityOctets;
unsigned int dot12TransitionIntoTrainings;
Phaal, et al. Informational [Page 22]
^L
RFC 3176 InMon Corporation's sFlow September 2001
unsigned hyper dot12HCInHighPriorityOctets;
unsigned hyper dot12HCInNormPriorityOctets;
unsigned hyper dot12HCOutHighPriorityOctets;
}
/* WAN counters */
struct wan_counters {
if_counters generic;
}
/* VLAN counters */
struct vlan_counters {
unsigned int vlan_id;
unsigned hyper octets;
unsigned int ucastPkts;
unsigned int multicastPkts;
unsigned int broadcastPkts;
unsigned int discards;
}
/* Counter data */
enum counters_version {
GENERIC = 1,
ETHERNET = 2,
TOKENRING = 3,
FDDI = 4,
VG = 5,
WAN = 6,
VLAN = 7
}
union counters_type (counters_version version) {
case GENERIC:
if_counters generic;
case ETHERNET:
ethernet_counters ethernet;
case TOKENRING:
tokenring_counters tokenring;
case FDDI:
fddi_counters fddi;
case VG:
vg_counters vg;
case WAN:
wan_counters wan;
case VLAN:
Phaal, et al. Informational [Page 23]
^L
RFC 3176 InMon Corporation's sFlow September 2001
vlan_counters vlan;
}
/* Format of a single counter sample */
struct counters_sample {
unsigned int sequence_number; /* Incremented with each counter
sample generated by this
source_id */
unsigned int source_id; /* sFlowDataSource encoded as
follows:
The most significant byte of the
source_id is used to indicate the
type of sFlowDataSource
(0 = ifIndex,
1 = smonVlanDataSource,
2 = entPhysicalEntry) and the
lower three
bytes contain the relevant
index value.*/
unsigned int sampling_interval; /* sFlowCounterSamplingInterval*/
counters_type counters;
}
/* Format of a sample datagram */
enum sample_types {
FLOWSAMPLE = 1,
COUNTERSSAMPLE = 2
}
union sample_type (sample_types sampletype) {
case FLOWSAMPLE:
flow_sample flowsample;
case COUNTERSSAMPLE:
counters_sample counterssample;
}
struct sample_datagram_v4 {
address agent_address /* IP address of sampling agent,
sFlowAgentAddress. */
unsigned int sequence_number; /* Incremented with each sample
datagram generated */
unsigned int uptime; /* Current time (in milliseconds since
device last booted). Should be set
as close to datagram transmission
time as possible.*/
Phaal, et al. Informational [Page 24]
^L
RFC 3176 InMon Corporation's sFlow September 2001
sample_type samples<>; /* An array of flow, counter and delay
samples */
}
enum datagram_version {
VERSION4 = 4
}
union sample_datagram_type (datagram_version version) {
case VERSION4:
sample_datagram_v4 datagram;
}
struct sample_datagram {
sample_datagram_type version;
}
The sFlow Datagram specification makes use of definitions from a
number of existing RFCs [22], [23], [24], [25], [26], [27] and [28].
5. Security Considerations
Deploying a traffic monitoring system raises a number of security
related issues. sFlow does not provide specific security mechanisms,
relying instead on proper deployment and configuration to maintain an
adequate level of security.
While the deployment of traffic monitoring systems does create some
risk, it also provides a powerful means of detecting and tracing
unauthorized network activity.
This section is intended to provide information that will help
understand potential risks and configuration options for mitigating
those risks.
5.1 Control
The sFlow MIB is used to configure the generation of sFlow samples.
The security of SNMP, with access control lists, is usually
considered adequate in an enterprise setting. However, there are
situations when these security measures are insufficient (for example
a WAN router) and SNMP configuration control will be disabled.
When SNMP is disabled, a command line interface is typically
provided. The following arguments are required to configure sFlow
sampling on an interface.
Phaal, et al. Informational [Page 25]
^L
RFC 3176 InMon Corporation's sFlow September 2001
-sFlowDataSource <source>
-sFlowPacketSamplingRate <rate>
-sFlowCounterSamplingInterval <interval>
-sFlowMaximumHeaderSize <header size>
-sFlowMaximumDatagramSize <datagram size>
-sFlowCollectorAddress <address>
-sFlowCollectorPort <port>
5.2 Transport
Traffic information is sent unencrypted across the network from the
sFlow Agent to the sFlow Analyzer and is thus vulnerable to
eavesdropping. This risk can be limited by creating a secure
measurement network and routing the sFlow Datagrams over this
network. The choice of technology for creating the secure
measurement network is deployment specific, but could include the use
of VLANs or VPN tunnels.
The sFlow Analyzer is vulnerable to attacks involving spoofed sFlow
Datagrams. To limit this vulnerability the sFlow Analyzer should
check sequence numbers and verify source addresses. If a secure
measurement network has been constructed then only sFlow Datagrams
received from that network should be processed.
5.3 Confidentiality
Traffic information can reveal confidential information about
individual network users. The degree of visibility of application
level data can be controlled by limiting the number of header bytes
captured by the sFlow agent. In addition, packet sampling makes it
virtually impossible to capture sequences of packets from an
individual transaction.
The traffic patterns discernible by decoding the sFlow Datagrams in
the sFlow Analyzer can reveal details of an individual's network
related activities and due care should be taken to secure access to
the sFlow Analyzer.
6. References
[1] Sun Microsystems, Inc., "XDR: External Data Representation
Standard", RFC 1014, June 1987.
[2] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture
for Describing SNMP Management Frameworks", RFC 2571, April
1999.
Phaal, et al. Informational [Page 26]
^L
RFC 3176 InMon Corporation's sFlow September 2001
[3] Rose, M. and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based Internets", STD 16, RFC
1155, May 1990.
[4] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
RFC 1212, March 1991.
[5] Rose, M., "A Convention for Defining Traps for use with the
SNMP", RFC 1215, March 1991.
[6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
[7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
RFC 2579, April 1999.
[8] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
58, RFC 2580, April 1999.
[9] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
Network Management Protocol", STD 15, RFC 1157, May 1990.
[10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Introduction to Community-based SNMPv2", RFC 1901, January
1996.
[11] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Transport Mappings for Version 2 of the Simple Network
Management Protocol (SNMPv2)", RFC 1906, January 1996.
[12] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
Processing and Dispatching for the Simple Network Management
Protocol (SNMP)", RFC 2572, April 1999.
[13] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
for version 3 of the Simple Network Management Protocol
(SNMPv3)", RFC 2574, April 1999.
[14] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
Operations for Version 2 of the Simple Network Management
Protocol (SNMPv2)", RFC 1905, January 1996.
[15] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
2573, April 1999.
Phaal, et al. Informational [Page 27]
^L
RFC 3176 InMon Corporation's sFlow September 2001
[16] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
Control Model (VACM) for the Simple Network Management Protocol
(SNMP)", RFC 2575, April 1999.
[17] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
to Version 3 of the Internet-standard Network Management
Framework", RFC 2570, April 1999.
[18] Waldbusser, S., "Remote Network Monitoring Management
Information Base", RFC 2819, May 2000.
[19] Waterman, R., Lahaye, B., Romascanu, D. and S. Waldbusser,
"Remote Network Monitoring MIB Extensions for Switched Networks
Version 1.0", RFC 2613, June 1999.
[20] Daniele, M., Haberman, B., Routhier, S. and J. Schoenwaelder,
"Textual Conventions for Internet Network Addresses", RFC 2851,
June 2000.
[21] Brownlee, N., "Traffic Flow Measurement: Meter MIB", RFC 2720,
October 1999.
[22] Smith, A., Flick, J., de Graaf, K., Romanscanu, D., McMaster,
D., McCloghrie, K. and S. Roberts, "Definition of Managed
Objects for IEEE 802.3 Medium Attachment Units (MAUs)", RFC
2668, August 1999.
[23] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB
using SMIv2", RFC 2233, November 1997.
[24] Flick, J. and J. Johnson, "Definition of Managed Objects for
the Ethernet-like Interface Types", RFC 2358, June 1998.
[25] Case, J., "FDDI Management Information Base", RFC 1512,
September 1993.
[26] McCloghrie, K. and E. Decker, "IEEE 802.5 MIB using SMIv2", RFC
1748, December 1994.
[27] Flick, J., "Definitions of Managed Objects for IEEE 802.12
Interfaces", RFC 2020, October 1996.
[28] Willis, S., Burruss, J. and J. Chu, "Definitions of Managed
Objects for the Fourth Version of the Border Gateway Protocol
(BGP-4) using SMIv2", RFC 1657, July 1994.
Phaal, et al. Informational [Page 28]
^L
RFC 3176 InMon Corporation's sFlow September 2001
7. Authors' Addresses
Peter Phaal
InMon Corporation
1404 Irving Street
San Francisco, CA 94122
Phone: (415) 661-6343
EMail: peter_phaal@INMON.COM
Sonia Panchen
InMon Corporation
1404 Irving Street
San Francisco, CA 94122
Phone: (415) 661-6343
EMail: sonia_panchen@INMON.COM
Neil McKee
InMon Corporation
1404 Irving Street
San Francisco, CA 94122
Phone: (415) 661-6343
EMail: neil_mckee@INMON.COM
Phaal, et al. Informational [Page 29]
^L
RFC 3176 InMon Corporation's sFlow September 2001
8. Intellectual Property Statement
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in BCP-11. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to
obtain a general license or permission for the use of such
proprietary rights by implementors or users of this specification can
be obtained from the IETF Secretariat.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.
Phaal, et al. Informational [Page 30]
^L
RFC 3176 InMon Corporation's sFlow September 2001
9. Full Copyright Statement
Copyright (C) The Internet Society (2001). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Phaal, et al. Informational [Page 31]
^L
|