1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
|
Network Working Group O. Nicklass, Ed.
Request for Comments: 3895 RAD Data Communications, Ltd.
Obsoletes: 2495 September 2004
Category: Standards Track
Definitions of Managed Objects
for the DS1, E1, DS2, and E2 Interface Types
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2004).
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes objects used for managing DS1, E1, DS2
and E2 interfaces. This document is a companion to the documents
that define Managed Objects for the DS0, DS3/E3 and Synchronous
Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface
Types. This document obsoletes RFC 2495.
Nicklass Standards Track [Page 1]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Table of Contents
1. The Internet-Standard Management Framework . . . . . . . . . . 2
1.1. Changes from RFC 2495. . . . . . . . . . . . . . . . . . 3
1.2. Changes from RFC 1406. . . . . . . . . . . . . . . . . . 3
1.3. Companion Documents. . . . . . . . . . . . . . . . . . . 4
2. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1. Use of ifTable for DS1 Layer . . . . . . . . . . . . . . 5
2.2. Usage Guidelines . . . . . . . . . . . . . . . . . . . . 6
2.2.1. Usage of ifStackTable for Routers and DSUs. . . . 6
2.2.2. Usage of ifStackTable for DS1/E1 on DS2/E2. . . . 8
2.2.3. Usage of Channelization for DS3, DS1, DS0 . . . . 9
2.2.4. Usage of Channelization for DS3, DS2, DS1 . . . . 10
2.2.5. Usage of Loopbacks. . . . . . . . . . . . . . . . 11
2.3. Objectives of this MIB Module. . . . . . . . . . . . . . 11
2.4. DS1 Terminology. . . . . . . . . . . . . . . . . . . . . 12
2.4.1. Error Events. . . . . . . . . . . . . . . . . . . 12
2.4.2. Performance Defects . . . . . . . . . . . . . . . 13
2.4.3. Performance Parameters. . . . . . . . . . . . . . 14
2.4.4. Failure States. . . . . . . . . . . . . . . . . . 18
2.4.5. Other Terms . . . . . . . . . . . . . . . . . . . 21
3. Object Definitions . . . . . . . . . . . . . . . . . . . . . . 21
4. Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . 74
5. Security Considerations. . . . . . . . . . . . . . . . . . . . 74
6. References . . . . . . . . . . . . . . . . . . . . . . . . . . 76
6.1. Normative References . . . . . . . . . . . . . . . . . . 76
6.2. Informative References . . . . . . . . . . . . . . . . . 78
Appendix A - Use of dsx1IfIndex and dsx1LineIndex. . . . . . . . . 79
Appendix B - The delay approach to Unavailable Seconds . . . . . . 81
Author's Address . . . . . . . . . . . . . . . . . . . . . . . . . 83
Full Copyright Statement . . . . . . . . . . . . . . . . . . . . . 84
1. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
Nicklass Standards Track [Page 2]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
1.1. Changes from RFC 2495
The changes from [RFC2495] are the following:
(1) The dsx1FracIfIndex SYNTAX matches the description range.
(2) A value was added to dsx1TransmitClockSource.
(3) Values were added to dsx1LineType.
(4) Two objects were added, dsx1LineMode and dsx1LineBuildOut to
better express transceiver mode and LineBuildOut for T1.
(5) Reference was added to Circuit Identifier object.
(6) Align the DESCRIPTION clauses of few statistic objects with the
near end definition, the far end definition and with [RFC3593].
(7) Changes in Compliance Statements to include new objects.
(8) A typographical error in dsx2E2 was fixed, new name is dsx1E2.
1.2. Changes from RFC 1406
The changes from RFC 1406 [RFC1406] are the following:
(1) The Fractional Table has been deprecated.
(2) This document uses SMIv2.
(3) Usage is given for ifTable and ifXTable.
(4) Example usage of ifStackTable is included.
(5) dsx1IfIndex has been deprecated.
(6) Support for DS2 and E2 have been added.
(7) Additional lineTypes for DS2, E2, and unframed E1 were added.
(8) The definition of valid intervals has been clarified for the
case where the agent proxied for other devices. In particular,
the treatment of missing intervals has been clarified.
(9) An inward loopback has been added.
Nicklass Standards Track [Page 3]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
(10) Additional lineStatus bits have been added for Near End in
Unavailable Signal State, Carrier Equipment Out of Service, DS2
Payload AIS, and DS2 Performance Threshold.
(11) A read-write line Length object has been added.
(12) Signal mode of other has been added.
(13) Added a lineStatus last change, trap and enabler.
(14) The e1(19) ifType has been obsoleted so this MIB does not list
it as a supported ifType.
(15) Textual Conventions for statistics objects have been used.
(16) A new object, dsx1LoopbackStatus has been introduced to reflect
the loopbacks established on a DS1 interface and the source to
the requests. dsx1LoopbackConfig continues to be the desired
loopback state while dsx1LoopbackStatus reflects the actual
state.
(17) A dual loopback has been added to allow the setting of an inward
loopback and a line loopback at the same time.
(18) An object indicating which channel to use within a parent object
(i.e., DS3) has been added.
(19) An object has been added to indicate whether or not this DS1/E1
is channelized.
(20) Line coding type of B6ZS has been added for DS2.
1.3. Companion Documents
This document is a companion to the documents that define Managed
Objects for the DS0 [RFC2494], DS3/E3 [RFC3896], and Synchronous
Optical Network/Synchronous Digital Hierarchy (SONET/SDH) [RFC3592]
Interface Types.
2. Overview
These objects are used when the particular media being used to
realize an interface is a DS1/E1/DS2/E2 interface. At present, this
applies to these values of the ifType variable in the Internet-
standard MIB:
ds1 (18)
Nicklass Standards Track [Page 4]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
The definitions contained herein are based on the AT&T T-1 Superframe
(a.k.a., D4) [ANSI-T1.107] and Extended Superframe (ESF) formats
[AT&T-UM-305] [AT&T-TR-54016], the latter of which conforms to ANSI
specification [ANSI-T1.403], and the CCITT Recommendations
[CCITT-G.703] [ITU-T-G.704], referred to as E1 for the rest of this
memo.
The various DS1 and E1 line disciplines are similar enough that
separate MIBs are unwarranted, although there are some differences.
For example, Loss of Frame is defined more rigorously in the ESF
specification than in the D4 specification, but it is defined in
both. Therefore, interface types e1(19) and g703at2mb(67) have been
obsoleted.
Where it is necessary to distinguish between the flavors of E1 with
and without CRC, E1-CRC denotes the "with CRC" form (G.704 Table 4b)
and E1-noCRC denotes the "without CRC" form (G.704 Table 4a).
2.1. Use of ifTable for DS1 Layer
Only the ifGeneralInformationGroup needs to be supported.
ifTable Object Use for DS1 Layer
======================================================================
ifIndex Interface index.
ifDescr See interfaces MIB [RFC2863]
ifType ds1(18)
ifSpeed Speed of line rate
DS1 - 1544000
E1 - 2048000
DS2 - 6312000
E2 - 8448000
ifPhysAddress The value of the Circuit Identifier.
If no Circuit Identifier has been assigned
this object should have an octet string
with zero length.
ifAdminStatus See interfaces MIB [RFC2863]
ifOperStatus See interfaces MIB [RFC2863]
ifLastChange See interfaces MIB [RFC2863]
ifName See interfaces MIB [RFC2863].
Nicklass Standards Track [Page 5]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ifLinkUpDownTrapEnable Set to enabled(1).
ifHighSpeed Speed of line in Mega-bits per second
(2, 6, or 8)
ifConnectorPresent Set to true(1) normally, except for
cases such as DS1/E1 over AAL1/ATM where
false(2) is appropriate
2.2. Usage Guidelines
2.2.1. Usage of ifStackTable for Routers and DSUs
The object dsx1IfIndex has been deprecated. This object previously
allowed a very special proxy situation to exist for Routers and CSUs.
This section now describes how to use ifStackTable to represent this
relationship.
The paragraphs discussing dsx1IfIndex and dsx1LineIndex have been
preserved in Appendix A for informational purposes.
The ifStackTable is used in the proxy case to represent the
association between pairs of interfaces, e.g., this T1 is attached to
that T1. This use is consistent with the use of the ifStackTable to
show the association between various sub-layers of an interface. In
both cases entire PDUs are exchanged between the interface pairs - in
the case of a T1, entire T1 frames are exchanged; in the case of PPP
and HDLC, entire HDLC frames are exchanged. This usage is not meant
to suggest the use of the ifStackTable to represent Time Division
Multiplexing (TDM) connections in general.
External&Internal interface scenario: the SNMP Agent resides on a
host external from the device supporting DS1 interfaces (e.g., a
router). The Agent represents both the host and the DS1 device.
Nicklass Standards Track [Page 6]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Example:
A shelf full of CSUs connected to a Router. An SNMP Agent residing
on the router proxies for itself and the CSU. The router has also an
Ethernet interface:
+-----+
| | |
| | | +---------------------+
|E | | 1.544 MBPS | Line#A | DS1 Link
|t | R |---------------+ - - - - - - - - - +------>
|h | | | |
|e | O | 1.544 MBPS | Line#B | DS1 Link
|r | |---------------+ - - - - - - - - - - +------>
|n | U | | CSU Shelf |
|e | | 1.544 MBPS | Line#C | DS1 Link
|t | T |---------------+ - - - -- -- - - - - +------>
| | | | |
|-----| E | 1.544 MBPS | Line#D | DS1 Link
| | |---------------+ - - - - -- - - - - +------>
| | R | |_____________________|
| | |
| +-----+
The assignment of the index values could for example be:
ifIndex Description
1 Ethernet
2 Line#A Router
3 Line#B Router
4 Line#C Router
5 Line#D Router
6 Line#A CSU Router
7 Line#B CSU Router
8 Line#C CSU Router
9 Line#D CSU Router
10 Line#A CSU Network
11 Line#B CSU Network
12 Line#C CSU Network
13 Line#D CSU Network
The ifStackTable is then used to show the relationships between the
various DS1 interfaces.
Nicklass Standards Track [Page 7]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ifStackTable Entries
HigherLayer LowerLayer
2 6
3 7
4 8
5 9
6 10
7 11
8 12
9 13
If the CSU shelf is managed by itself by a local SNMP Agent, the
situation would be identical, except the Ethernet and the 4 router
interfaces are deleted. Interfaces would also be numbered from 1 to
8.
ifIndex Description
1 Line#A CSU Router
2 Line#B CSU Router
3 Line#C CSU Router
4 Line#D CSU Router
5 Line#A CSU Network
6 Line#B CSU Network
7 Line#C CSU Network
8 Line#D CSU Network
ifStackTable Entries
HigherLayer LowerLayer
1 5
2 6
3 7
4 8
2.2.2. Usage of ifStackTable for DS1/E1 on DS2/E2
An example is given of how DS1/E1 interfaces are stacked on DS2/E2
interfaces. It is not necessary nor is it always desirable to
represent DS2 interfaces. If this is required, the following
stacking should be used. All ifTypes are ds1. The DS2 is determined
by examining ifSpeed or dsx1LineType.
Nicklass Standards Track [Page 8]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ifIndex Description
1 DS1 #1
2 DS1 #2
3 DS1 #3
4 DS1 #4
5 DS2
ifStackTable Entries
HigherLayer LowerLayer
1 5
2 5
3 5
4 5
2.2.3. Usage of Channelization for DS3, DS1, DS0
An example is given here to explain the channelization objects in the
DS3, DS1, and DS0 MIBs to help the implementor use the objects
correctly. Treatment of E3 and E1 would be similar, with the number
of DS0s being different depending on the framing of the E1.
Assume that a DS3 (with ifIndex 1) is Channelized into DS1s (without
DS2s). The object dsx3Channelization is set to enabledDs1. There
will be 28 DS1s in the ifTable. Assume the entries in the ifTable
for the DS1s are created in channel order and the ifIndex values are
2 through 29. In the DS1 MIB, there will be an entry in the
dsx1ChanMappingTable for each ds1. The entries will be as follows:
dsx1ChanMappingTable Entries
ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex
1 1 2
1 2 3
......
1 28 29
In addition, the DS1s are channelized into DS0s. The object
dsx1Channelization is set to enabledDS0 for each DS1. When this
object is set to this value, 24 DS0s are created by the agent. There
will be 24 DS0s in the ifTable for each DS1. If the
dsx1Channelization is set to disabled, the 24 DS0s are destroyed.
Assume the entries in the ifTable are created in channel order and
the ifIndex values for the DS0s in the first DS1 are 30 through 53.
In the DS0 MIB, there will be an entry in the dsx0ChanMappingTable
for each DS0. The entries will be as follows:
Nicklass Standards Track [Page 9]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx0ChanMappingTable Entries
ifIndex dsx0Ds0ChannelNumber dsx0ChanMappedIfIndex
2 1 30
2 2 31
......
2 24 53
2.2.4. Usage of Channelization for DS3, DS2, DS1
An example is given here to explain the channelization objects in the
DS3 and DS1 MIBs to help the implementor use the objects correctly.
Assume that a DS3 (with ifIndex 1) is Channelized into DS2s. The
object dsx3Channelization [RFC3896] is set to enabledDs2. There will
be 7 DS2s (ifType of DS1) in the ifTable. Assume the entries in the
ifTable for the DS2s are created in channel order and the ifIndex
values are 2 through 8. In the DS1 MIB, there will be an entry in
the dsx1ChanMappingTable for each DS2. The entries will be as
follows:
dsx1ChanMappingTable Entries
ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex
1 1 2
1 2 3
......
1 7 8
In addition, the DS2s are channelized into DS1s. The object
dsx1Channelization is set to enabledDS1 for each DS2. There will be
4 DS1s in the ifTable for each DS2. Assume the entries in the
ifTable are created in channel order and the ifIndex values for the
DS1s in the first DS2 are 9 through 12, then 13 through 16 for the
second DS2, and so on. In the DS1 MIB, there will be an entry in the
dsx1ChanMappingTable for each DS1. The entries will be as follows:
dsx1ChanMappingTable Entries
ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex
2 1 9
2 2 10
2 3 11
2 4 12
3 1 13
3 2 14
...
8 4 36
Nicklass Standards Track [Page 10]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
2.2.5. Usage of Loopbacks
This section discusses the behaviour of objects related to loopbacks.
The object dsx1LoopbackConfig represents the desired state of
loopbacks on this interface. Using this object a Manager can
request:
LineLoopback
PayloadLoopback (if ESF framing)
InwardLoopback
DualLoopback (Line + Inward)
NoLoopback
The remote end can also request loopbacks either through the FDL
channel if ESF or inband if D4. The loopbacks that can be requested
this way are:
LineLoopback
PayloadLoopback (if ESF framing)
NoLoopback
To model the current state of loopbacks on a DS1 interface, the
object dsx1LoopbackStatus defines which loopback is currently applied
to an interface. This objects, which is a bitmap, will have bits
turned on which reflect the currently active loopbacks on the
interface as well as the source of those loopbacks.
The following restrictions/rules apply to loopbacks:
The far end cannot undo loopbacks set by a manager.
A manager can undo loopbacks set by the far end.
Both a line loopback and an inward loopback can be set at the same
time. Only these two loopbacks can co-exist and either one may be
set by the manager or the far end. A LineLoopback request from the
far end is incremental to an existing Inward loopback established by
a manager. When a NoLoopback is received from the far end in this
case, the InwardLoopback remains in place.
2.3. Objectives of this MIB Module
There are numerous things that could be included in a MIB for DS1
signals: the management of multiplexors, CSUs, DSUs, and the like.
The intent of this document is to facilitate the common management of
all devices with DS1, E1, DS2, or E3 interfaces. As such, a design
Nicklass Standards Track [Page 11]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
decision was made up front to very closely align the MIB with the set
of objects that can generally be read from these types devices that
are currently deployed.
J2 interfaces are not supported by this MIB.
2.4. DS1 Terminology
The terminology used in this document to describe error conditions on
a DS1 interface as monitored by a DS1 device are based on the late
but not final document of what became the ANSI T1.231 standard
[ANSI-T1.231]. If the definition in this document does not match the
definition in the ANSI T1.231 document, the implementer should follow
the definition described in this document.
2.4.1. Error Events
Bipolar Violation (BPV) Error Event
A BPV error event for an AMI-coded signal is the occurrence of a
pulse of the same polarity as the previous pulse (See T1.231
Section 6.1.1.1.1). A BPV error event for a B8ZS- or HDB3-coded
signal is the occurrence of a pulse of the same polarity as the
previous pulse without being a part of the zero substitution
code.
Excessive Zeroes (EXZ) Error Event
An Excessive Zeroes error event for an AMI-coded signal is the
occurrence of more than fifteen contiguous zeroes (See T1.231
Section 6.1.1.1.2). For a B8ZS coded signal, the defect occurs
when more than seven contiguous zeroes are detected.
Line Coding Violation (LCV) Error Event
A Line Coding Violation (LCV) is the occurrence of either a
Bipolar Violation (BPV) or Excessive Zeroes (EXZ) Error Event.
(Also known as CV-L; See T1.231 Section 6.5.1.1.)
Path Coding Violation (PCV) Error Event
A Path Coding Violation error event is a frame synchronization
bit error in the D4 and E1-noCRC formats, or a CRC or frame
synch. bit error in the ESF and E1-CRC formats. (Also known as
CV-P; See T1.231 Section 6.5.2.1.)
Controlled Slip (CS) Error Event
A Controlled Slip is the replication or deletion of the payload
bits of a DS1 frame (See T1.231 Section 6.1.1.2.3). A
Controlled Slip may be performed when there is a difference
Nicklass Standards Track [Page 12]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
between the timing of a synchronous receiving terminal and the
received signal. A Controlled Slip does not cause an Out of
Frame defect.
2.4.2. Performance Defects
Out Of Frame (OOF) Defect
An OOF defect is the occurrence of a particular density of
Framing Error events (See T1.231 Section 6.1.2.2.1).
For DS1 links, an Out of Frame defect is declared when the
receiver detects two or more framing errors within a 3 msec
period for ESF signals and 0.75 msec for D4 signals, or two or
more errors out of five or fewer consecutive framing-bits.
For E1 links, an Out Of Frame defect is declared when three
consecutive frame alignment signals have been received with an
error (see G.706 Section 4.1 [CCITT-G.706]).
For DS2 links, an Out of Frame defect is declared when 7 or more
consecutive errored framing patterns (4 multiframe) are
received. The OOF is cleared when 3 or more consecutive correct
framing patterns are received.
Once an Out Of Frame Defect is declared, the framer starts
searching for a correct framing pattern. The Out of Frame
defect ends when the signal is in frame.
In-frame occurs when there are fewer than two frame bit errors
within 3 msec period for ESF signals and 0.75 msec for D4
signals.
For E1 links, in-frame occurs when a) in frame N the frame
alignment signal is correct and b) in frame N+1 the frame
alignment signal is absent (i.e., bit 2 in TS0 is a one) and c)
in frame N+2 the frame alignment signal is present and correct.
(See G.704 Section 4.1)
Alarm Indication Signal (AIS) Defect
For D4 and ESF links, the 'all ones' condition is detected at a
DS1 line interface upon observing an unframed signal with a
one's density of at least 99.9% present for a time equal to or
greater than T, where 3 ms <= T <= 75 ms. The AIS is terminated
upon observing a signal not meeting the one's density or the
unframed signal criteria for a period equal to or greater than T
(See G.775, Section 5.4).
Nicklass Standards Track [Page 13]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
For E1 links, the 'all-ones' condition is detected at the line
interface as a string of 512 bits containing fewer than three
zero bits (see O.162 [CCITT-O.162] Section 3.3.2).
For DS2 links, the DS2 AIS shall be sent from the NT1 to the
user to indicate a loss of the 6,312 kbps frame capability on
the network side. The DS2 AIS is defined as a bit array of
6,312 kbps in which all binary bits are set to '1'.
The DS2 AIS detection and removal shall be implemented according
to ITU-T Draft Recommendation G.775 [ITU-T-G.775] Section 5.5:
- a DS2 AIS defect is detected when the incoming signal has
two (2) or less ZEROs in a sequence of 3156 bits (0.5 ms).
- a DS2 AIS defect is cleared when the incoming signal has
three (3) or more ZEROs in a sequence of 3156 bits (0.5 ms).
2.4.3. Performance Parameters
All performance parameters are accumulated in fifteen minute
intervals and up to 96 intervals (24 hours worth) are kept by an
agent. Fewer than 96 intervals of data will be available if the
agent has been restarted within the last 24 hours. In addition,
there is a rolling 24-hour total of each performance parameter.
Performance parameters continue to be collected when the interface is
down.
There is no requirement for an agent to ensure fixed relationship
between the start of a fifteen minute interval and any wall clock;
however some agents may align the fifteen minute intervals with
quarter hours.
Performance parameters are of types PerfCurrentCount,
PerfIntervalCount and PerfTotalCount. These textual conventions are
all Gauge32, and they are used because it is possible for these
objects to decrease. Objects may decrease when Unavailable Seconds
occurs across a fifteen minutes interval boundary. See Unavailable
Seconds discussion later in this section.
Line Errored Seconds (LES)
A Line Errored Second is a second in which one or more Line Code
Violation error events were detected. (Also known as ES-L; See
T1.231 Section 6.5.1.2.)
Controlled Slip Seconds (CSS)
A Controlled Slip Second is a one-second interval containing one
or more controlled slips (See T1.231 Section 6.5.2.8). This is
not incremented during an Unavailable Second.
Nicklass Standards Track [Page 14]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Errored Seconds (ES)
For ESF and E1-CRC links an Errored Second is a second with one
or more Path Code Violation OR one or more Out of Frame defects
OR one or more Controlled Slip events OR a detected AIS defect.
(See T1.231 Section 6.5.2.2 and G.826 [ITU-T-G.826] Section
B.1).
For D4 and E1-noCRC links, the presence of Bipolar Violations
also triggers an Errored Second.
This is not incremented during an Unavailable Second.
Bursty Errored Seconds (BES)
A Bursty Errored Second (also known as Errored Second type B in
T1.231 Section 6.5.2.4) is a second with fewer than 320 and more
than 1 Path Coding Violation error events, no Severely Errored
Frame defects and no detected incoming AIS defects. Controlled
slips are not included in this parameter.
This is not incremented during an Unavailable Second. It
applies to ESF signals only.
Severely Errored Seconds (SES)
A Severely Errored Second for ESF signals is a second with 320
or more Path Code Violation Error Events OR one or more Out of
Frame defects OR a detected AIS defect (See T1.231 Section
6.5.2.5).
For E1-CRC signals, a Severely Errored Second is a second with
832 or more Path Code Violation error events OR one or more Out
of Frame defects.
For E1-noCRC signals, a Severely Errored Second is a 2048 LCVs
or more.
For D4 signals, a Severely Errored Second is a count of one-
second intervals with Framing Error events, or an OOF defect, or
1544 LCVs or more.
Controlled slips are not included in this parameter.
This is not incremented during an Unavailable Second.
Severely Errored Framing Second (SEFS)
An Severely Errored Framing Second is a second with one or more
Out of Frame defects OR a detected AIS defect. (Also known as
SAS-P (SEF/AIS second); See T1.231 Section 6.5.2.6.)
Nicklass Standards Track [Page 15]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Degraded Minutes
A Degraded Minute is one in which the estimated error rate
exceeds 1E-6 but does not exceed 1E-3 (see G.821 [CCITT-G.821]).
Degraded Minutes are determined by collecting all of the
Available Seconds, removing any Severely Errored Seconds
grouping the result in 60-second long groups and counting a 60-
second long group (a.k.a., minute) as degraded if the cumulative
errors during the seconds present in the group exceed 1E-6.
Available seconds are merely those seconds which are not
Unavailable as described below.
Unavailable Seconds (UAS)
Unavailable Seconds (UAS) are calculated by counting the number
of seconds that the interface is unavailable. The DS1 interface
is said to be unavailable from the onset of 10 contiguous SESs,
or the onset of the condition leading to a failure (see Failure
States). If the condition leading to the failure was
immediately preceded by one or more contiguous SESs, then the
DS1 interface unavailability starts from the onset of these
SESs. Once unavailable, and if no failure is present, the DS1
interface becomes available at the onset of 10 contiguous
seconds with no SESs. Once unavailable, and if a failure is
present, the DS1 interface becomes available at the onset of 10
contiguous seconds with no SESs, if the failure clearing time is
less than or equal to 10 seconds. If the failure clearing time
is more than 10 seconds, the DS1 interface becomes available at
the onset of 10 contiguous seconds with no SESs, or the onset
period leading to the successful clearing condition, whichever
occurs later. With respect to the DS1 error counts, all
counters are incremented while the DS1 interface is deemed
available. While the interface is deemed unavailable, the only
count that is incremented is UASs.
Note that this definition implies that the agent cannot
determine until after a ten second interval has passed whether a
given one-second interval belongs to available or unavailable
time. If the agent chooses to update the various performance
statistics in real time then it must be prepared to
retroactively reduce the ES, BES, SES, and SEFS counts by 10 and
increase the UAS count by 10 when it determines that available
time has been entered. It must also be prepared to adjust the
PCV count and the DM count as necessary since these parameters
are not accumulated during unavailable time. It must be
similarly prepared to retroactively decrease the UAS count by 10
and increase the ES, BES, and DM counts as necessary upon
entering available time. A special case exists when the 10
second period leading to available or unavailable time crosses a
Nicklass Standards Track [Page 16]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
900 second statistics window boundary, as the foregoing
description implies that the ES, BES, SES, SEFS, DM, and UAS
counts the PREVIOUS interval must be adjusted. In this case
successive GETs of the affected dsx1IntervalSESs and
dsx1IntervalUASs objects will return differing values if the
first GET occurs during the first few seconds of the window.
The agent may instead choose to delay updates to the various
statistics by 10 seconds in order to avoid retroactive
adjustments to the counters. A way to do this is sketched in
Appendix B.
In any case, a linkDown trap shall be sent only after the agent has
determined for certain that the unavailable state has been entered,
but the time on the trap will be that of the first UAS (i.e., 10
seconds earlier). A linkUp trap shall be handled similarly.
According to ANSI T1.231 unavailable time begins at the _onset_ of 10
contiguous severely errored seconds -- that is, unavailable time
starts with the _first_ of the 10 contiguous SESs. Also, while an
interface is deemed unavailable all counters for that interface are
frozen except for the UAS count. It follows that an implementation
which strictly complies with this standard must _not_ increment any
counters other than the UAS count -- even temporarily -- as a result
of anything that happens during those 10 seconds. Since changes in
the signal state lag the data to which they apply by 10 seconds, an
ANSI-compliant implementation must pass the one-second statistics
through a 10-second delay line prior to updating any counters. That
can be done by performing the following steps at the end of each one
second interval.
i) Read near/far end CV counter and alarm status flags from the
hardware.
ii) Accumulate the CV counts for the preceding second and compare
them to the ES and SES threshold for the layer in question.
Update the signal state and shift the one-second CV counts and
ES/SES flags into the 10-element delay line. Note that far-end
one-second statistics are to be flagged as "absent" during any
second in which there is an incoming defect at the layer in
question or at any lower layer.
iii) Update the current interval statistics using the signal state
from the _previous_ update cycle and the one-second CV counts
and ES/SES flags shifted out of the 10-element delay line.
This approach is further described in Appendix B.
Nicklass Standards Track [Page 17]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
2.4.4. Failure States
The following failure states are received, or detected failures, that
are reported in the dsx1LineStatus object. When a DS1 interface
would, if ever, produce the conditions leading to the failure state
is described in the appropriate specification.
Far End Alarm Failure
The Far End Alarm failure is also known as "Yellow Alarm" in the
DS1 case, "Distant Alarm" in the E1 case, and "Remote Alarm" in
the DS2 case.
For D4 links, the Far End Alarm failure is declared when bit 6
of all channels has been zero for at least 335 ms and is cleared
when bit 6 of at least one channel is non-zero for a period T,
where T is usually less than one second and always less than 5
seconds. The Far End Alarm failure is not declared for D4 links
when a Loss of Signal is detected.
For ESF links, the Far End Alarm failure is declared if the
Yellow Alarm signal pattern occurs in at least seven out of ten
contiguous 16-bit pattern intervals and is cleared if the Yellow
Alarm signal pattern does not occur in ten contiguous 16-bit
signal pattern intervals.
For E1 links, the Far End Alarm failure is declared when bit 3
of time-slot zero is received set to one on two consecutive
occasions. The Far End Alarm failure is cleared when bit 3 of
time-slot zero is received set to zero.
For DS2 links, if a loss of frame alignment (LOF or LOS) and/or
DS2 AIS condition, is detected, the RAI signal shall be
generated and transmitted to the remote side.
The Remote Alarm Indication(RAI) signal is defined on m-bits as
a repetition of the 16bit sequence consisting of eight binary
'1s' and eight binary '0s' in m-bits(1111111100000000). When
the RAI signal is not sent (in normal operation),the HDLC flag
pattern (01111110) in the m-bit is sent.
The RAI failure is detected when 16 or more consecutive RAI-
patterns (1111111100000000) are received. The RAI failure is
cleared when 4 or more consecutive incorrect-RAI-patterns are
received.
Alarm Indication Signal (AIS) Failure
The Alarm Indication Signal failure is declared when an AIS
defect is detected at the input and the AIS defect still exists
Nicklass Standards Track [Page 18]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
after the Loss Of Frame failure (which is caused by the unframed
nature of the 'all-ones' signal) is declared. The AIS failure
is cleared when the Loss Of Frame failure is cleared. (See
T1.231 Section 6.2.1.2.1)
An AIS defect at a 6312 kbit/s (G.704) interface is detected
when the incoming signal has two {2} or less ZEROs in a sequence
of 3156 bits (0.5ms). The AIS signal defect is cleared when the
incoming signal has three {3} or more ZEROs in a sequence of
3156 bits (0.5ms).
Loss Of Frame Failure
For DS1 links, the Loss Of Frame failure is declared when an OOF
or LOS defect has persisted for T seconds, where 2 <= T <= 10.
The Loss Of Frame failure is cleared when there have been no OOF
or LOS defects during a period T where 0 <= T <= 20. Many
systems will perform "hit integration" within the period T
before declaring or clearing the failure e.g., see TR 62411
[AT&T-TR-62411].
For E1 links, the Loss Of Frame Failure is declared when an OOF
defect is detected.
Loss Of Signal Failure
For DS1, the Loss Of Signal failure is declared upon observing
175 +/- 75 contiguous pulse positions with no pulses of either
positive or negative polarity. The LOS failure is cleared upon
observing an average pulse density of at least 12.5% over a
period of 175 +/- 75 contiguous pulse positions starting with
the receipt of a pulse.
For E1 links, the Loss Of Signal failure is declared when
greater than 10 consecutive zeroes are detected (see O.162
Section 3.4.4).
A LOS defect at 6312kbit/s interfaces is detected when the
incoming signal has "no transitions", i.e., when the signal
level is less than or equal to a signal level of 35dB below
nominal, for N consecutive pulse intervals, where 10 <=N<=255.
The LOS defect is cleared when the incoming signal has
"transitions", i.e., when the signal level is greater than or
equal to a signal level of 9dB below nominal, for N consecutive
pulse intervals, where 10<=N<=255.
A signal with "transitions" corresponds to a G.703 compliant
signal.
Nicklass Standards Track [Page 19]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Loopback Pseudo-Failure
The Loopback Pseudo-Failure is declared when the near end
equipment has placed a loopback (of any kind) on the DS1. This
allows a management entity to determine from one object whether
the DS1 can be considered to be in service or not (from the
point of view of the near end equipment).
TS16 Alarm Indication Signal Failure
For E1 links, the TS16 Alarm Indication Signal failure is
declared when time-slot 16 is received as all ones for all
frames of two consecutive multiframes (see G.732 Section 4.2.6).
This condition is never declared for DS1.
Loss Of MultiFrame Failure
The Loss Of MultiFrame failure is declared when two consecutive
multiframe alignment signals (bits 4 through 7 of TS16 of frame
0) have been received with an error. The Loss Of Multiframe
failure is cleared when the first correct multiframe alignment
signal is received. The Loss Of Multiframe failure can only be
declared for E1 links operating with G.732 [CCITT-G.732] framing
(sometimes called "Channel Associated Signalling" mode).
Far End Loss Of Multiframe Failure
The Far End Loss Of Multiframe failure is declared when bit 2 of
TS16 of frame 0 is received set to one on two consecutive
occasions. The Far End Loss Of Multiframe failure is cleared
when bit 2 of TS16 of frame 0 is received set to zero. The Far
End Loss Of Multiframe failure can only be declared for E1 links
operating in "Channel Associated Signalling" mode (See G.732).
DS2 Payload AIS Failure
The DS2 Payload AIS is detected when the incoming signal of the
6,312 kbps frame payload (time-slots 1 through 96) has 2 or less
0's in a sequence of 3072 bits (0.5ms). The DS2 Payload AIS is
cleared when the incoming signal of the 6,312 kbps frame payload
has 3 or more 0's in a sequence of 3072 bits (0.5 ms).
DS2 Performance Threshold
DS2 Performance Threshold Failure monitors equipment performance
and is based on the CRC (Cyclic Redundancy Check) Procedure
defined in G.704.
The DS2 Performance Threshold Failure is detected when the bit
error ratio exceeds 10^-4 (Performance Threshold), and the DS2
Performance Threshold Failure shall be cleared when the bit
error ratio decreased to less than 10^-6."
Nicklass Standards Track [Page 20]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
2.4.5. Other Terms
Circuit Identifier
This is a character string specified by the circuit vendor, and is
useful when communicating with the vendor during the
troubleshooting process (see M.1400 [ITU-T-M.1400] for additional
information).
Proxy
In this document, the word proxy is meant to indicate an
application which receives SNMP messages and replies to them on
behalf of the devices which implement the actual DS1/E1
interfaces. The proxy may have already collected the information
about the DS1/E1 interfaces into its local database and may not
necessarily forward the requests to the actual DS1/E1 interface.
It is expected in such an application that there are periods of
time where the proxy is not communicating with the DS1/E1
interfaces. In these instances the proxy will not necessarily
have up-to-date configuration information and will most likely
have missed the collection of some statistics data. Missed
statistics data collection will result in invalid data in the
interval table.
3. Object Definitions
DS1-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, transmission
FROM SNMPv2-SMI -- [RFC2578]
DisplayString, TimeStamp, TruthValue
FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF -- [RFC2580]
InterfaceIndex, ifIndex
FROM IF-MIB -- [RFC2863]
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount
FROM PerfHist-TC-MIB; -- [RFC3593]
ds1 MODULE-IDENTITY
LAST-UPDATED "200409090000Z" -- September 09, 2004
ORGANIZATION "IETF AToM MIB Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/atommib-charter.html
Nicklass Standards Track [Page 21]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Mailing Lists:
General Discussion: atommib@research.telcordia.com
To Subscribe: atommib-request@research.telcordia.com
Editor: Orly Nicklass
Postal: RAD Data Communications, Ltd.
Ziv Tower, 24 Roul Walenberg
Tel Aviv, Israel, 69719
Tel: +9723 765 9969
E-mail: orly_n@rad.com"
DESCRIPTION
"The MIB module to describe DS1, E1, DS2, and
E2 interfaces objects.
Copyright (c) The Internet Society (2004). This
version of this MIB module is part of RFC 3895;
see the RFC itself for full legal notices."
REVISION "200409090000Z" -- September 09, 2004
DESCRIPTION
"The RFC 3895 version of this MIB module.
The key changes made to this MIB module
since its publication in RFC 2495 are as follows:
(1) The dsx1FracIfIndex SYNTAX matches the description range.
(2) A value was added to dsx1TransmitClockSource.
(3) Values were added to dsx1LineType.
(4) Two objects were added, dsx1LineMode and dsx1LineBuildOut
to better express transceiver mode and LineBuildOut for T1.
(5) Reference was added to Circuit Identifier object.
(6) Align the DESCRIPTION clauses of few statistic objects with
the near end definition, the far end definition and with
RFC 3593.
(7) Changes in Compliance Statements to include new objects.
(8) A typographical error in dsx2E2 was fixed, new name is dsx1E2."
REVISION "199808011830Z"
DESCRIPTION
"The RFC 2495 version of this MIB module.
The key changes made to this MIB module
since its publication in RFC 1406 are as follows:
(1) The Fractional Table has been deprecated.
(2) This document uses SMIv2.
(3) Usage is given for ifTable and ifXTable.
(4) Example usage of ifStackTable is included.
(5) dsx1IfIndex has been deprecated.
Nicklass Standards Track [Page 22]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
(6) Support for DS2 and E2 have been added.
(7) Additional lineTypes for DS2, E2, and unframed E1
were added.
(8) The definition of valid intervals has been clarified
for the case where the agent proxied for other devices. In
particular, the treatment of missing intervals has been
clarified.
(9) An inward loopback has been added.
(10) Additional lineStatus bits have been added for Near End in
Unavailable Signal State, Carrier Equipment Out of Service,
DS2 Payload AIS, and DS2 Performance Threshold.
(11) A read-write line Length object has been added.
(12) Signal mode of other has been added.
(13) Added a lineStatus last change, trap and enabler.
(14) The e1(19) ifType has been obsoleted so this MIB
does not list it as a supported ifType.
(15) Textual Conventions for statistics objects have been used.
(16) A new object, dsx1LoopbackStatus has been introduced to
reflect the loopbacks established on a DS1 interface and
the source to the requests. dsx1LoopbackConfig continues
to be the desired loopback state while dsx1LoopbackStatus
reflects the actual state.
(17) A dual loopback has been added to allow the setting of an
inward loopback and a line loopback at the same time.
(18) An object indicating which channel to use within a parent
object (i.e., DS3) has been added.
(19) An object has been added to indicate whether or not this
DS1/E1 is channelized.
(20) Line coding type of B6ZS has been added for DS2"
REVISION "199301252028Z"
DESCRIPTION
"Initial version, published as RFC 1406."
::= { transmission 18 }
-- note that this subsumes cept (19) and g703at2mb (67)
-- there is no separate CEPT or G703AT2MB MIB
-- The DS1 Near End Group
-- The DS1 Near End Group consists of five tables:
-- DS1 Configuration
-- DS1 Current
-- DS1 Interval
-- DS1 Total
-- DS1 Channel Table
Nicklass Standards Track [Page 23]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
-- The DS1 Configuration Table
dsx1ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Configuration table."
::= { ds1 6 }
dsx1ConfigEntry OBJECT-TYPE
SYNTAX Dsx1ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Configuration table."
INDEX { dsx1LineIndex }
::= { dsx1ConfigTable 1 }
Dsx1ConfigEntry ::=
SEQUENCE {
dsx1LineIndex InterfaceIndex,
dsx1IfIndex InterfaceIndex,
dsx1TimeElapsed INTEGER,
dsx1ValidIntervals INTEGER,
dsx1LineType INTEGER,
dsx1LineCoding INTEGER,
dsx1SendCode INTEGER,
dsx1CircuitIdentifier DisplayString,
dsx1LoopbackConfig INTEGER,
dsx1LineStatus INTEGER,
dsx1SignalMode INTEGER,
dsx1TransmitClockSource INTEGER,
dsx1Fdl INTEGER,
dsx1InvalidIntervals INTEGER,
dsx1LineLength INTEGER,
dsx1LineStatusLastChange TimeStamp,
dsx1LineStatusChangeTrapEnable INTEGER,
dsx1LoopbackStatus INTEGER,
dsx1Ds1ChannelNumber INTEGER,
dsx1Channelization INTEGER,
dsx1LineMode INTEGER,
dsx1LineBuildOut INTEGER
}
dsx1LineIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
Nicklass Standards Track [Page 24]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
-- SMIv1 index
STATUS current
DESCRIPTION
"This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex allows proper
use of ifStackTable and ds0/ds0bundle mibs.
Previously, this object is the identifier of a DS1
Interface on a managed device. If there is an
ifEntry that is directly associated with this and
only this DS1 interface, it should have the same
value as ifIndex. Otherwise, number the
dsx1LineIndices with an unique identifier
following the rules of choosing a number that is
greater than ifNumber and numbering the inside
interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g., network side)
with odd numbers."
::= { dsx1ConfigEntry 1 }
dsx1IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This value for this object is equal to the value
of ifIndex from the Interfaces table of MIB II
(RFC 1213)."
::= { dsx1ConfigEntry 2 }
dsx1TimeElapsed OBJECT-TYPE
SYNTAX INTEGER (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the near end current error-measurement
period. If, for some reason, such as an adjustment
in the system's time-of-day clock, the current interval
exceeds the maximum value, the agent will return the
maximum value."
::= { dsx1ConfigEntry 3 }
dsx1ValidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
Nicklass Standards Track [Page 25]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
DESCRIPTION
"The number of previous near end intervals for
which data was collected. The value will be 96
unless the interface was brought online within the
last 24 hours, in which case the value will be the
number of complete 15 minute near end intervals
since the interface has been online. In the case
where the agent is a proxy, it is possible that
some intervals are unavailable. In this case,
this interval is the maximum interval number for
which data is available."
::= { dsx1ConfigEntry 4 }
dsx1LineType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
dsx1ESF(2),
dsx1D4(3),
dsx1E1(4),
dsx1E1CRC(5),
dsx1E1MF(6),
dsx1E1CRCMF(7),
dsx1Unframed(8),
dsx1E1Unframed(9),
dsx1DS2M12(10),
dsx1E2(11),
dsx1E1Q50(12),
dsx1E1Q50CRC(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the variety of DS1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error
statistics. The values, in sequence, describe:
TITLE: SPECIFICATION:
dsx1ESF Extended SuperFrame DS1
(T1.107)
dsx1D4 AT&T D4 format DS1 (T1.107)
dsx1E1 ITU-T Recommendation G.704
(Table 4a)
dsx1E1-CRC ITU-T Recommendation G.704
(Table 4b)
dsxE1-MF G.704 (Table 4a) with TS16
Nicklass Standards Track [Page 26]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
multiframing enabled
dsx1E1-CRC-MF G.704 (Table 4b) with TS16
multiframing enabled
dsx1Unframed DS1 with No Framing
dsx1E1Unframed E1 with No Framing (G.703)
dsx1DS2M12 DS2 frame format (T1.107)
dsx1E2 E2 frame format (G.704)
dsx1E1Q50 TS16 bits 5,7,8 set to 101, [in
all other cases it is set
to 111.](ITU-T G.704,table 14)
dsx1E1Q50CRC E1Q50 with CRC.
For clarification, the capacity for each E1 type
is as listed below:
dsx1E1Unframed - E1, no framing = 32 x 64k = 2048k
dsx1E1 or dsx1E1CRC - E1, with framing,
no signalling = 31 x 64k = 1984k
dsx1E1MF or dsx1E1CRCMF - E1, with framing,
signalling = 30 x 64k = 1920k"
REFERENCE
"American National Standard for telecommunications -
digital hierarchy - formats specification,
ANSI-T1.107 - 1988.
CCITT Specifications Volume III, Recommendation
G.703, Physical/Electrical Characteristics
of Hierarchical Digital Interfaces, April 1991.
ITU-T-G.704: Synchronous frame structures used at
1544, 6312, 2048, 8488 and 44 736 kbit/s
Hierarchical Levels, July 1995."
::= { dsx1ConfigEntry 5 }
dsx1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
dsx1JBZS (1),
dsx1B8ZS (2),
dsx1HDB3 (3),
dsx1ZBTSI (4),
dsx1AMI (5),
other(6),
dsx1B6ZS(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the variety of Zero Code
Suppression used on this interface, which in turn
affects a number of its characteristics.
Nicklass Standards Track [Page 27]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1JBZS refers the Jammed Bit Zero Suppression,
in which the AT&T specification of at least one
pulse every 8 bit periods is literally implemented
by forcing a pulse in bit 8 of each channel.
Thus, only seven bits per channel, or 1.344 Mbps,
is available for data.
dsx1B8ZS refers to the use of a specified pattern
of normal bits and bipolar violations which are
used to replace a sequence of eight zero bits.
ANSI Clear Channels may use dsx1ZBTSI, or Zero
Byte Time Slot Interchange.
E1 links, with or without CRC, use dsx1HDB3 or
dsx1AMI.
dsx1AMI refers to a mode wherein no zero code
suppression is present and the line encoding does
not solve the problem directly. In this
application, the higher layer must provide data
which meets or exceeds the pulse density
requirements, such as inverting HDLC data.
dsx1B6ZS refers to the user of a specified pattern
of normal bits and bipolar violations which are
used to replace a sequence of six zero bits. Used
for DS2."
::= { dsx1ConfigEntry 6 }
dsx1SendCode OBJECT-TYPE
SYNTAX INTEGER {
dsx1SendNoCode(1),
dsx1SendLineCode(2),
dsx1SendPayloadCode(3),
dsx1SendResetCode(4),
dsx1SendQRS(5),
dsx1Send511Pattern(6),
dsx1Send3in24Pattern(7),
dsx1SendOtherTestPattern(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates what type of code is
being sent across the DS1 interface by the device.
Setting this variable causes the interface to send
the code requested. The values mean:
Nicklass Standards Track [Page 28]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1SendNoCode
sending looped or normal data
dsx1SendLineCode
sending a request for a line loopback
dsx1SendPayloadCode
sending a request for a payload loopback
dsx1SendResetCode
sending a loopback termination request
dsx1SendQRS
sending a Quasi-Random Signal (QRS) test
pattern
dsx1Send511Pattern
sending a 511 bit fixed test pattern
dsx1Send3in24Pattern
sending a fixed test pattern of 3 bits set
in 24
dsx1SendOtherTestPattern
sending a test pattern other than those
described by this object"
::= { dsx1ConfigEntry 7 }
dsx1CircuitIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable contains the transmission vendor's
circuit identifier, for the purpose of
facilitating troubleshooting."
REFERENCE "ITU-T M.1400"
::= { dsx1ConfigEntry 8 }
dsx1LoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
dsx1NoLoop(1),
dsx1PayloadLoop(2),
dsx1LineLoop(3),
dsx1OtherLoop(4),
dsx1InwardLoop(5),
dsx1DualLoop(6)
}
Nicklass Standards Track [Page 29]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the desired loopback
configuration of the DS1 interface. Agents
supporting read/write access should return
inconsistentValue in response to a requested
loopback state that the interface does not
support. The values mean:
dsx1NoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on the interface
shall always return this as its value.
dsx1PayloadLoop
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.
dsx1LineLoop
The received signal at this interface does not go
through the device (minimum penetration) but is
looped back out.
dsx1OtherLoop
Loopbacks that are not defined here.
dsx1InwardLoop
The transmitted signal at this interface is
looped back and received by the same interface.
What is transmitted onto the line is product
dependent.
dsx1DualLoop
Both dsx1LineLoop and dsx1InwardLoop will be
active simultaneously."
::= { dsx1ConfigEntry 9 }
dsx1LineStatus OBJECT-TYPE
SYNTAX INTEGER (1..131071)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Line Status of the
interface. It contains loopback, failure,
received 'alarm' and transmitted 'alarms
Nicklass Standards Track [Page 30]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
information.
The dsx1LineStatus is a bit map represented as a
sum, therefore, it can represent multiple failures
(alarms) and a LoopbackState simultaneously.
dsx1NoAlarm must be set if and only if no other
flag is set.
If the dsx1loopbackState bit is set, the loopback
in effect can be determined from the
dsx1loopbackConfig object. The various bit
positions are:
1 dsx1NoAlarm No alarm present
2 dsx1RcvFarEndLOF Far end LOF (a.k.a., Yellow Alarm)
4 dsx1XmtFarEndLOF Near end sending LOF Indication
8 dsx1RcvAIS Far end sending AIS
16 dsx1XmtAIS Near end sending AIS
32 dsx1LossOfFrame Near end LOF (a.k.a., Red Alarm)
64 dsx1LossOfSignal Near end Loss Of Signal
128 dsx1LoopbackState Near end is looped
256 dsx1T16AIS E1 TS16 AIS
512 dsx1RcvFarEndLOMF Far End Sending TS16 LOMF
1024 dsx1XmtFarEndLOMF Near End Sending TS16 LOMF
2048 dsx1RcvTestCode Near End detects a test code
4096 dsx1OtherFailure any line status not defined here
8192 dsx1UnavailSigState Near End in Unavailable Signal
State
16384 dsx1NetEquipOOS Carrier Equipment Out of Service
32768 dsx1RcvPayloadAIS DS2 Payload AIS
65536 dsx1Ds2PerfThreshold DS2 Performance Threshold
Exceeded"
::= { dsx1ConfigEntry 10 }
dsx1SignalMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
robbedBit (2),
bitOriented (3),
messageOriented (4),
other (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'none' indicates that no bits are reserved for
signaling on this channel.
Nicklass Standards Track [Page 31]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
'robbedBit' indicates that DS1 Robbed Bit Signaling
is in use.
'bitOriented' indicates that E1 Channel
Associated Signaling is in use.
'messageOriented' indicates that Common
Channel Signaling is in use either on channel 16
of an E1 link or channel 24 of a DS1."
::= { dsx1ConfigEntry 11 }
dsx1TransmitClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
adaptive (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
'loopTiming' indicates that the recovered
receive clock is used as the transmit clock.
'localTiming' indicates that a local clock
source is used or when an external clock is
attached to the box containing the interface.
'throughTiming' indicates that recovered
receive clock from another interface is used as
the transmit clock.
'adaptive' indicates that the clock is recovered
based on the data flow and not based on the
physical layer"
::= { dsx1ConfigEntry 12 }
dsx1Fdl OBJECT-TYPE
SYNTAX INTEGER (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This bitmap describes the use of the facilities
data link, and is the sum of the capabilities.
Set any bits that are appropriate:
other(1),
Nicklass Standards Track [Page 32]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1AnsiT1403(2),
dsx1Att54016(4),
dsx1FdlNone(8)
'other' indicates that a protocol other than
one following is used.
'dsx1AnsiT1403' refers to the FDL exchange
recommended by ANSI.
'dsx1Att54016' refers to ESF FDL exchanges.
'dsx1FdlNone' indicates that the device does
not use the FDL."
::= { dsx1ConfigEntry 13 }
dsx1InvalidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of intervals in the range from 0 to
dsx1ValidIntervals for which no data is available.
This object will typically be zero except in cases
where the data for some intervals are not
available (e.g., in proxy situations)."
::= { dsx1ConfigEntry 14 }
dsx1LineLength OBJECT-TYPE
SYNTAX INTEGER (0..64000)
UNITS "meters"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of the ds1 line in meters. This
objects provides information for line build out
circuitry. This object is only useful if the
interface has configurable line build out
circuitry."
::= { dsx1ConfigEntry 15 }
dsx1LineStatusLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of MIB II's sysUpTime object at the
time this DS1 entered its current line status
Nicklass Standards Track [Page 33]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
state. If the current state was entered prior to
the last re-initialization of the proxy-agent,
then this object contains a zero value."
::= { dsx1ConfigEntry 16 }
dsx1LineStatusChangeTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether dsx1LineStatusChange traps
should be generated for this interface."
DEFVAL { disabled }
::= { dsx1ConfigEntry 17 }
dsx1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER (1..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable represents the current state of the
loopback on the DS1 interface. It contains
information about loopbacks established by a
manager and remotely from the far end.
The dsx1LoopbackStatus is a bit map represented as
a sum, therefore is can represent multiple
loopbacks simultaneously.
The various bit positions are:
1 dsx1NoLoopback
2 dsx1NearEndPayloadLoopback
4 dsx1NearEndLineLoopback
8 dsx1NearEndOtherLoopback
16 dsx1NearEndInwardLoopback
32 dsx1FarEndPayloadLoopback
64 dsx1FarEndLineLoopback"
::= { dsx1ConfigEntry 18 }
dsx1Ds1ChannelNumber OBJECT-TYPE
SYNTAX INTEGER (0..28)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 34]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"This variable represents the channel number of
the DS1/E1 on its parent DS2/E2 or DS3/E3. A
value of 0 indicated this DS1/E1 does not have a
parent DS3/E3."
::= { dsx1ConfigEntry 19 }
dsx1Channelization OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabledDs0(2),
enabledDs1(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether this ds1/e1 is channelized or
unchannelized. The value of enabledDs0 indicates
that this is a DS1 channelized into DS0s. The
value of enabledDs1 indicated that this is a DS2
channelized into DS1s. Setting this value will
cause the creation or deletion of entries in the
ifTable for the DS0s that are within the DS1."
::= { dsx1ConfigEntry 20 }
dsx1LineMode OBJECT-TYPE
SYNTAX INTEGER {
csu(1),
dsu(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This setting puts the T1 framer into either long
haul (CSU) mode or short haul (DSU) mode."
::= { dsx1ConfigEntry 21 }
dsx1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
neg75dB (2),
neg15dB (3),
neg225dB (4),
zerodB (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 35]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"Attenuation setting for T1 framer in long haul
(CSU) mode. The optional values are: -7.5dB,
-15dB, -22.5dB and 0dB."
::= { dsx1ConfigEntry 22 }
-- The DS1 Current Table
dsx1CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 current table contains various statistics
being collected for the current 15 minute
interval."
::= { ds1 7 }
dsx1CurrentEntry OBJECT-TYPE
SYNTAX Dsx1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Current table."
INDEX { dsx1CurrentIndex }
::= { dsx1CurrentTable 1 }
Dsx1CurrentEntry ::=
SEQUENCE {
dsx1CurrentIndex InterfaceIndex,
dsx1CurrentESs PerfCurrentCount,
dsx1CurrentSESs PerfCurrentCount,
dsx1CurrentSEFSs PerfCurrentCount,
dsx1CurrentUASs PerfCurrentCount,
dsx1CurrentCSSs PerfCurrentCount,
dsx1CurrentPCVs PerfCurrentCount,
dsx1CurrentLESs PerfCurrentCount,
dsx1CurrentBESs PerfCurrentCount,
dsx1CurrentDMs PerfCurrentCount,
dsx1CurrentLCVs PerfCurrentCount
}
dsx1CurrentIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable.
Nicklass Standards Track [Page 36]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
The interface identified by a particular value of
this index is the same interface as identified by
the same value as a dsx1LineIndex object
instance."
::= { dsx1CurrentEntry 1 }
dsx1CurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds."
::= { dsx1CurrentEntry 2 }
dsx1CurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds."
::= { dsx1CurrentEntry 3 }
dsx1CurrentSEFSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Framing Seconds."
::= { dsx1CurrentEntry 4 }
dsx1CurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds."
::= { dsx1CurrentEntry 5 }
dsx1CurrentCSSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Controlled Slip Seconds."
::= { dsx1CurrentEntry 6 }
dsx1CurrentPCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
Nicklass Standards Track [Page 37]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Path Coding Violations."
::= { dsx1CurrentEntry 7 }
dsx1CurrentLESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds."
::= { dsx1CurrentEntry 8 }
dsx1CurrentBESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds."
::= { dsx1CurrentEntry 9 }
dsx1CurrentDMs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Degraded Minutes."
::= { dsx1CurrentEntry 10 }
dsx1CurrentLCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Code Violations (LCVs)."
::= { dsx1CurrentEntry 11 }
-- The DS1 Interval Table
dsx1IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Interval Table contains various
statistics collected by each DS1 Interface over
the previous 24 hours of operation. The past 24
hours are broken into 96 completed 15 minute
Nicklass Standards Track [Page 38]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
intervals. Each row in this table represents one
such interval (identified by dsx1IntervalNumber)
for one specific instance (identified by
dsx1IntervalIndex)."
::= { ds1 8 }
dsx1IntervalEntry OBJECT-TYPE
SYNTAX Dsx1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Interval table."
INDEX { dsx1IntervalIndex, dsx1IntervalNumber }
::= { dsx1IntervalTable 1 }
Dsx1IntervalEntry ::=
SEQUENCE {
dsx1IntervalIndex InterfaceIndex,
dsx1IntervalNumber INTEGER,
dsx1IntervalESs PerfIntervalCount,
dsx1IntervalSESs PerfIntervalCount,
dsx1IntervalSEFSs PerfIntervalCount,
dsx1IntervalUASs PerfIntervalCount,
dsx1IntervalCSSs PerfIntervalCount,
dsx1IntervalPCVs PerfIntervalCount,
dsx1IntervalLESs PerfIntervalCount,
dsx1IntervalBESs PerfIntervalCount,
dsx1IntervalDMs PerfIntervalCount,
dsx1IntervalLCVs PerfIntervalCount,
dsx1IntervalValidData TruthValue
}
dsx1IntervalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS1
interface to which this entry is applicable. The
interface identified by a particular value of this
index is the same interface as identified by the
same value as a dsx1LineIndex object instance."
::= { dsx1IntervalEntry 1 }
dsx1IntervalNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS read-only -- read-only since originally an
Nicklass Standards Track [Page 39]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
-- SMIv1 index
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the 15 minutes interval completed 23 hours and 45
minutes prior to interval 1."
::= { dsx1IntervalEntry 2 }
dsx1IntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds."
::= { dsx1IntervalEntry 3 }
dsx1IntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds."
::= { dsx1IntervalEntry 4 }
dsx1IntervalSEFSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Framing Seconds."
::= { dsx1IntervalEntry 5 }
dsx1IntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds. This object
may decrease if the occurrence of unavailable
seconds occurs across an interval boundary."
::= { dsx1IntervalEntry 6 }
dsx1IntervalCSSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 40]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"The number of Controlled Slip Seconds."
::= { dsx1IntervalEntry 7 }
dsx1IntervalPCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Path Coding Violations."
::= { dsx1IntervalEntry 8 }
dsx1IntervalLESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds."
::= { dsx1IntervalEntry 9 }
dsx1IntervalBESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds."
::= { dsx1IntervalEntry 10 }
dsx1IntervalDMs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Degraded Minutes."
::= { dsx1IntervalEntry 11 }
dsx1IntervalLCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Code Violations."
::= { dsx1IntervalEntry 12 }
dsx1IntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 41]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"This variable indicates if the data for this
interval is valid."
::= { dsx1IntervalEntry 13 }
-- The DS1 Total Table
dsx1TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Total Table contains the cumulative sum
of the various statistics for the 24 hour period
preceding the current interval."
::= { ds1 9 }
dsx1TotalEntry OBJECT-TYPE
SYNTAX Dsx1TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Total table."
INDEX { dsx1TotalIndex }
::= { dsx1TotalTable 1 }
Dsx1TotalEntry ::=
SEQUENCE {
dsx1TotalIndex InterfaceIndex,
dsx1TotalESs PerfTotalCount,
dsx1TotalSESs PerfTotalCount,
dsx1TotalSEFSs PerfTotalCount,
dsx1TotalUASs PerfTotalCount,
dsx1TotalCSSs PerfTotalCount,
dsx1TotalPCVs PerfTotalCount,
dsx1TotalLESs PerfTotalCount,
dsx1TotalBESs PerfTotalCount,
dsx1TotalDMs PerfTotalCount,
dsx1TotalLCVs PerfTotalCount
}
dsx1TotalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS1
interface to which this entry is applicable. The
interface identified by a particular value of this
Nicklass Standards Track [Page 42]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
index is the same interface as identified by the
same value as a dsx1LineIndex object instance."
::= { dsx1TotalEntry 1 }
dsx1TotalESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of Errored Seconds encountered by a DS1
interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1TotalEntry 2 }
dsx1TotalSESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1TotalEntry 3 }
dsx1TotalSEFSs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Framing Seconds
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1TotalEntry 4 }
dsx1TotalUASs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds encountered by
a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1TotalEntry 5 }
dsx1TotalCSSs OBJECT-TYPE
SYNTAX PerfTotalCount
Nicklass Standards Track [Page 43]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Controlled Slip Seconds encountered
by a DS1 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as
0."
::= { dsx1TotalEntry 6 }
dsx1TotalPCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Path Coding Violations encountered
by a DS1 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as
0."
::= { dsx1TotalEntry 7 }
dsx1TotalLESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Errored Seconds encountered by
a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1TotalEntry 8 }
dsx1TotalBESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds (BESs)
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1TotalEntry 9 }
dsx1TotalDMs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Degraded Minutes (DMs) encountered
by a DS1 interface in the previous 24 hour
Nicklass Standards Track [Page 44]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
interval. Invalid 15 minute intervals count as
0."
::= { dsx1TotalEntry 10 }
dsx1TotalLCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Line Code Violations (LCVs)
encountered by a DS1 interface in the current 15
minute interval. Invalid 15 minute intervals
count as 0."
::= { dsx1TotalEntry 11 }
-- The DS1 Channel Table
dsx1ChanMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1ChanMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Channel Mapping table. This table maps a
DS1 channel number on a particular DS3 into an
ifIndex. In the presence of DS2s, this table can
be used to map a DS2 channel number on a DS3 into
an ifIndex, or used to map a DS1 channel number on
a DS2 onto an ifIndex."
::= { ds1 16 }
dsx1ChanMappingEntry OBJECT-TYPE
SYNTAX Dsx1ChanMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Channel Mapping table. There
is an entry in this table corresponding to each
ds1 ifEntry within any interface that is
channelized to the individual ds1 ifEntry level.
This table is intended to facilitate mapping from
channelized interface / channel number to DS1
ifEntry. (e.g., mapping (DS3 ifIndex, DS1 Channel
Number) -> ifIndex)
While this table provides information that can
also be found in the ifStackTable and
dsx1ConfigTable, it provides this same information
with a single table lookup, rather than by walking
Nicklass Standards Track [Page 45]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
the ifStackTable to find the various constituent
ds1 ifTable entries, and testing various
dsx1ConfigTable entries to check for the entry
with the applicable DS1 channel number."
INDEX { ifIndex, dsx1Ds1ChannelNumber }
::= { dsx1ChanMappingTable 1 }
Dsx1ChanMappingEntry ::=
SEQUENCE {
dsx1ChanMappedIfIndex InterfaceIndex
}
dsx1ChanMappedIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the ifIndex value assigned
by the agent for the individual ds1 ifEntry that
corresponds to the given DS1 channel number
(specified by the INDEX element
dsx1Ds1ChannelNumber) of the given channelized
interface (specified by INDEX element ifIndex)."
::= { dsx1ChanMappingEntry 1 }
-- The DS1 Far End Current Table
dsx1FarEndCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1FarEndCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Far End Current table contains various
statistics being collected for the current 15
minute interval. The statistics are collected
from the far end messages on the Facilities Data
Link. The definitions are the same as described
for the near-end information."
::= { ds1 10 }
dsx1FarEndCurrentEntry OBJECT-TYPE
SYNTAX Dsx1FarEndCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Far End Current table."
INDEX { dsx1FarEndCurrentIndex }
::= { dsx1FarEndCurrentTable 1 }
Nicklass Standards Track [Page 46]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Dsx1FarEndCurrentEntry ::=
SEQUENCE {
dsx1FarEndCurrentIndex InterfaceIndex,
dsx1FarEndTimeElapsed INTEGER,
dsx1FarEndValidIntervals INTEGER,
dsx1FarEndCurrentESs PerfCurrentCount,
dsx1FarEndCurrentSESs PerfCurrentCount,
dsx1FarEndCurrentSEFSs PerfCurrentCount,
dsx1FarEndCurrentUASs PerfCurrentCount,
dsx1FarEndCurrentCSSs PerfCurrentCount,
dsx1FarEndCurrentLESs PerfCurrentCount,
dsx1FarEndCurrentPCVs PerfCurrentCount,
dsx1FarEndCurrentBESs PerfCurrentCount,
dsx1FarEndCurrentDMs PerfCurrentCount,
dsx1FarEndInvalidIntervals INTEGER
}
dsx1FarEndCurrentIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS1
interface to which this entry is applicable. The
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx1LineIndex."
::= { dsx1FarEndCurrentEntry 1 }
dsx1FarEndTimeElapsed OBJECT-TYPE
SYNTAX INTEGER (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the far end current error-measurement
period. If, for some reason, such as an adjustment
in the system's time-of-day clock, the current
interval exceeds the maximum value, the agent will
return the maximum value."
::= { dsx1FarEndCurrentEntry 2 }
dsx1FarEndValidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 47]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"The number of previous far end intervals for
which data was collected. The value will be 96
unless the interface was brought online within the
last 24 hours, in which case the value will be the
number of complete 15 minute far end intervals
since the interface has been online. In the case
where the agent is a proxy, it is possible that
some intervals are unavailable. In this case,
this interval is the maximum interval number for
which data is available."
::= { dsx1FarEndCurrentEntry 3 }
dsx1FarEndCurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Errored Seconds."
::= { dsx1FarEndCurrentEntry 4 }
dsx1FarEndCurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Seconds."
::= { dsx1FarEndCurrentEntry 5 }
dsx1FarEndCurrentSEFSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Framing
Seconds."
::= { dsx1FarEndCurrentEntry 6 }
dsx1FarEndCurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds."
::= { dsx1FarEndCurrentEntry 7 }
dsx1FarEndCurrentCSSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
Nicklass Standards Track [Page 48]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
STATUS current
DESCRIPTION
"The number of Far End Controlled Slip Seconds."
::= { dsx1FarEndCurrentEntry 8 }
dsx1FarEndCurrentLESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Line Errored Seconds."
::= { dsx1FarEndCurrentEntry 9 }
dsx1FarEndCurrentPCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Path Coding Violations."
::= { dsx1FarEndCurrentEntry 10 }
dsx1FarEndCurrentBESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Bursty Errored Seconds."
::= { dsx1FarEndCurrentEntry 11 }
dsx1FarEndCurrentDMs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Degraded Minutes."
::= { dsx1FarEndCurrentEntry 12 }
dsx1FarEndInvalidIntervals OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of intervals in the range from 0 to
dsx1FarEndValidIntervals for which no data is
available. This object will typically be zero
except in cases where the data for some intervals
are not available (e.g., in proxy situations)."
::= { dsx1FarEndCurrentEntry 13 }
Nicklass Standards Track [Page 49]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
-- The DS1 Far End Interval Table
dsx1FarEndIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1FarEndIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Far End Interval Table contains various
statistics collected by each DS1 interface over
the previous 24 hours of operation. The past 24
hours are broken into 96 completed 15 minute
intervals. Each row in this table represents one
such interval (identified by
dsx1FarEndIntervalNumber) for one specific
instance (identified by dsx1FarEndIntervalIndex)."
::= { ds1 11 }
dsx1FarEndIntervalEntry OBJECT-TYPE
SYNTAX Dsx1FarEndIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Far End Interval table."
INDEX { dsx1FarEndIntervalIndex,
dsx1FarEndIntervalNumber }
::= { dsx1FarEndIntervalTable 1 }
Dsx1FarEndIntervalEntry ::=
SEQUENCE {
dsx1FarEndIntervalIndex InterfaceIndex,
dsx1FarEndIntervalNumber INTEGER,
dsx1FarEndIntervalESs PerfIntervalCount,
dsx1FarEndIntervalSESs PerfIntervalCount,
dsx1FarEndIntervalSEFSs PerfIntervalCount,
dsx1FarEndIntervalUASs PerfIntervalCount,
dsx1FarEndIntervalCSSs PerfIntervalCount,
dsx1FarEndIntervalLESs PerfIntervalCount,
dsx1FarEndIntervalPCVs PerfIntervalCount,
dsx1FarEndIntervalBESs PerfIntervalCount,
dsx1FarEndIntervalDMs PerfIntervalCount,
dsx1FarEndIntervalValidData TruthValue
}
dsx1FarEndIntervalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
Nicklass Standards Track [Page 50]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"The index value which uniquely identifies the DS1
interface to which this entry is applicable. The
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx1LineIndex."
::= { dsx1FarEndIntervalEntry 1 }
dsx1FarEndIntervalNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the 15 minutes interval completed 23 hours and 45
minutes prior to interval 1."
::= { dsx1FarEndIntervalEntry 2 }
dsx1FarEndIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Errored Seconds."
::= { dsx1FarEndIntervalEntry 3 }
dsx1FarEndIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Seconds."
::= { dsx1FarEndIntervalEntry 4 }
dsx1FarEndIntervalSEFSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Framing
Seconds."
::= { dsx1FarEndIntervalEntry 5 }
dsx1FarEndIntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
Nicklass Standards Track [Page 51]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
DESCRIPTION
"The number of Unavailable Seconds."
::= { dsx1FarEndIntervalEntry 6 }
dsx1FarEndIntervalCSSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Controlled Slip Seconds."
::= { dsx1FarEndIntervalEntry 7 }
dsx1FarEndIntervalLESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Line Errored Seconds."
::= { dsx1FarEndIntervalEntry 8 }
dsx1FarEndIntervalPCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Path Coding Violations."
::= { dsx1FarEndIntervalEntry 9 }
dsx1FarEndIntervalBESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Bursty Errored Seconds."
::= { dsx1FarEndIntervalEntry 10 }
dsx1FarEndIntervalDMs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Degraded Minutes."
::= { dsx1FarEndIntervalEntry 11 }
dsx1FarEndIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
Nicklass Standards Track [Page 52]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
DESCRIPTION
" This variable indicates if the data for this
interval is valid."
::= { dsx1FarEndIntervalEntry 12 }
-- The DS1 Far End Total Table
dsx1FarEndTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1FarEndTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Far End Total Table contains the
cumulative sum of the various statistics for the
24 hour period preceding the current interval."
::= { ds1 12 }
dsx1FarEndTotalEntry OBJECT-TYPE
SYNTAX Dsx1FarEndTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Far End Total table."
INDEX { dsx1FarEndTotalIndex }
::= { dsx1FarEndTotalTable 1 }
Dsx1FarEndTotalEntry ::=
SEQUENCE {
dsx1FarEndTotalIndex InterfaceIndex,
dsx1FarEndTotalESs PerfTotalCount,
dsx1FarEndTotalSESs PerfTotalCount,
dsx1FarEndTotalSEFSs PerfTotalCount,
dsx1FarEndTotalUASs PerfTotalCount,
dsx1FarEndTotalCSSs PerfTotalCount,
dsx1FarEndTotalLESs PerfTotalCount,
dsx1FarEndTotalPCVs PerfTotalCount,
dsx1FarEndTotalBESs PerfTotalCount,
dsx1FarEndTotalDMs PerfTotalCount
}
dsx1FarEndTotalIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION
"The index value which uniquely identifies the DS1
interface to which this entry is applicable. The
Nicklass Standards Track [Page 53]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
interface identified by a particular value of this
index is identical to the interface identified by
the same value of dsx1LineIndex."
::= { dsx1FarEndTotalEntry 1 }
dsx1FarEndTotalESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Errored Seconds encountered
by a DS1 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as
0."
::= { dsx1FarEndTotalEntry 2 }
dsx1FarEndTotalSESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Seconds
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1FarEndTotalEntry 3 }
dsx1FarEndTotalSEFSs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Severely Errored Framing
Seconds encountered by a DS1 interface in the
previous 24 hour interval. Invalid 15 minute
intervals count as 0."
::= { dsx1FarEndTotalEntry 4 }
dsx1FarEndTotalUASs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds encountered by
a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1FarEndTotalEntry 5 }
Nicklass Standards Track [Page 54]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1FarEndTotalCSSs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Controlled Slip Seconds
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1FarEndTotalEntry 6 }
dsx1FarEndTotalLESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Line Errored Seconds
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1FarEndTotalEntry 7 }
dsx1FarEndTotalPCVs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Far End Path Coding Violations
reported via the far end block error count
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1FarEndTotalEntry 8 }
dsx1FarEndTotalBESs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds (BESs)
encountered by a DS1 interface in the previous 24
hour interval. Invalid 15 minute intervals count
as 0."
::= { dsx1FarEndTotalEntry 9 }
dsx1FarEndTotalDMs OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
Nicklass Standards Track [Page 55]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
STATUS current
DESCRIPTION
"The number of Degraded Minutes (DMs) encountered
by a DS1 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as
0."
::= { dsx1FarEndTotalEntry 10 }
-- The DS1 Fractional Table
dsx1FracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1FracEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is deprecated in favour of using
ifStackTable.
The table was mandatory for systems dividing a DS1
into channels containing different data streams
that are of local interest. Systems which are
indifferent to data content, such as CSUs, need
not implement it.
The DS1 fractional table identifies which DS1
channels associated with a CSU are being used to
support a logical interface, i.e., an entry in the
interfaces table from the Internet-standard MIB.
For example, consider an application managing a
North American ISDN Primary Rate link whose
division is a 384 kbit/s H1 _B_ Channel for Video,
a second H1 for data to a primary routing peer,
and 12 64 kbit/s H0 _B_ Channels. Consider that
some subset of the H0 channels are used for voice
and the remainder are available for dynamic data
calls.
We count a total of 14 interfaces multiplexed onto
the DS1 interface. Six DS1 channels (for the sake
of the example, channels 1..6) are used for Video,
six more (7..11 and 13) are used for data, and the
remaining 12 are in channels 12 and 14..24.
Let us further imagine that ifIndex 2 is of type
DS1 and refers to the DS1 interface, and that the
interfaces layered onto it are numbered 3..16.
We might describe the allocation of channels, in
Nicklass Standards Track [Page 56]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
the dsx1FracTable, as follows:
dsx1FracIfIndex.2. 1 = 3 dsx1FracIfIndex.2.13 = 4
dsx1FracIfIndex.2. 2 = 3 dsx1FracIfIndex.2.14 = 6
dsx1FracIfIndex.2. 3 = 3 dsx1FracIfIndex.2.15 = 7
dsx1FracIfIndex.2. 4 = 3 dsx1FracIfIndex.2.16 = 8
dsx1FracIfIndex.2. 5 = 3 dsx1FracIfIndex.2.17 = 9
dsx1FracIfIndex.2. 6 = 3 dsx1FracIfIndex.2.18 = 10
dsx1FracIfIndex.2. 7 = 4 dsx1FracIfIndex.2.19 = 11
dsx1FracIfIndex.2. 8 = 4 dsx1FracIfIndex.2.20 = 12
dsx1FracIfIndex.2. 9 = 4 dsx1FracIfIndex.2.21 = 13
dsx1FracIfIndex.2.10 = 4 dsx1FracIfIndex.2.22 = 14
dsx1FracIfIndex.2.11 = 4 dsx1FracIfIndex.2.23 = 15
dsx1FracIfIndex.2.12 = 5 dsx1FracIfIndex.2.24 = 16
For North American (DS1) interfaces, there are 24
legal channels, numbered 1 through 24.
For G.704 interfaces, there are 31 legal channels,
numbered 1 through 31. The channels (1..31)
correspond directly to the equivalently numbered
time-slots."
::= { ds1 13 }
dsx1FracEntry OBJECT-TYPE
SYNTAX Dsx1FracEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the DS1 Fractional table."
INDEX { dsx1FracIndex, dsx1FracNumber }
::= { dsx1FracTable 1 }
Dsx1FracEntry ::=
SEQUENCE {
dsx1FracIndex INTEGER,
dsx1FracNumber INTEGER,
dsx1FracIfIndex INTEGER
}
dsx1FracIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION
"The index value which uniquely identifies the
DS1 interface to which this entry is applicable
The interface identified by a particular
Nicklass Standards Track [Page 57]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
value of this index is the same interface as
identified by the same value an dsx1LineIndex
object instance."
::= { dsx1FracEntry 1 }
dsx1FracNumber OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION
"The channel number for this entry."
::= { dsx1FracEntry 2 }
dsx1FracIfIndex OBJECT-TYPE
SYNTAX INTEGER (0..'7fffffff'h)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"An index value that uniquely identifies an
interface. The interface identified by a particular
value of this index is the same interface
as identified by the same value an ifIndex
object instance. If no interface is currently using
a channel, the value should be zero. If a
single interface occupies more than one time
slot, that ifIndex value will be found in multiple
time slots."
::= { dsx1FracEntry 3 }
-- DS1 TRAPS
ds1Traps OBJECT IDENTIFIER ::= { ds1 15 }
dsx1LineStatusChange NOTIFICATION-TYPE
OBJECTS { dsx1LineStatus,
dsx1LineStatusLastChange }
STATUS current
DESCRIPTION
"A dsx1LineStatusChange trap is sent when the
value of an instance dsx1LineStatus changes. It
can be utilized by an NMS to trigger polls. When
the line status change results from a higher level
line status change (i.e., ds3), then no traps for
the ds1 are sent."
::= { ds1Traps 0 1 }
-- conformance information
Nicklass Standards Track [Page 58]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ds1Conformance OBJECT IDENTIFIER ::= { ds1 14 }
ds1Groups OBJECT IDENTIFIER ::= { ds1Conformance 1 }
ds1Compliances OBJECT IDENTIFIER ::= { ds1Conformance 2 }
-- compliance statements
ds1Compliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for T1 and E1
interfaces."
MODULE -- this module
MANDATORY-GROUPS { ds1NearEndConfigGroup,
ds1NearEndStatisticsGroup }
GROUP ds1FarEndGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS1 Interface."
GROUP ds1NearEndOptionalConfigGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS1 Interface."
GROUP ds1DS2Group
DESCRIPTION
"Implementation of this group is mandatory for all
systems that attach to a DS2 Interface."
GROUP ds1TransStatsGroup
DESCRIPTION
"This group is the set of statistics appropriate
for all systems which attach to a DS1 Interface
running transparent or unFramed lineType."
GROUP ds1ChanMappingGroup
DESCRIPTION
"This group is the set of objects for mapping a
DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex.
Implementation of this group is mandatory for
systems which support the channelization of DS3s
into DS1s."
OBJECT dsx1LineType
SYNTAX INTEGER {
Nicklass Standards Track [Page 59]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
other(1),
dsx1ESF(2),
dsx1D4(3),
dsx1E1(4),
dsx1E1CRC(5),
dsx1E1MF(6),
dsx1E1CRCMF(7),
dsx1Unframed(8),
dsx1E1Unframed(9),
dsx1DS2M12(10),
dsx1E2(11)
}
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line type is not
required."
OBJECT dsx1LineCoding
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line coding is not
required."
OBJECT dsx1SendCode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the send code is not
required."
OBJECT dsx1LoopbackConfig
MIN-ACCESS read-only
DESCRIPTION
"The ability to set loopbacks is not required."
OBJECT dsx1SignalMode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the signal mode is not
required."
OBJECT dsx1TransmitClockSource
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3)
}
MIN-ACCESS read-only
DESCRIPTION
Nicklass Standards Track [Page 60]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
"The ability to set the transmit clock source is
not required."
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the FDL is not required."
OBJECT dsx1LineLength
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line length is not
required."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization is not
required."
::= { ds1Compliances 1 }
ds1MibT1PriCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Compliance statement for using this MIB for ISDN
Primary Rate interfaces on T1 lines."
MODULE
MANDATORY-GROUPS { ds1NearEndConfigGroup,
ds1NearEndStatisticsGroup }
OBJECT dsx1LineType
SYNTAX INTEGER {
dsx1ESF(2) -- Intl Spec would be G704(2)
-- or I.431(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Line type for T1 ISDN Primary Rate
interfaces."
OBJECT dsx1LineCoding
SYNTAX INTEGER {
dsx1B8ZS(2)
}
MIN-ACCESS read-only
DESCRIPTION
"Type of Zero Code Suppression for
T1 ISDN Primary Rate interfaces."
Nicklass Standards Track [Page 61]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
OBJECT dsx1SignalMode
SYNTAX INTEGER {
none(1), -- if there is no signaling channel
messageOriented(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Possible signaling modes for
T1 ISDN Primary Rate interfaces."
OBJECT dsx1TransmitClockSource
SYNTAX INTEGER {
loopTiming(1)
}
MIN-ACCESS read-only
DESCRIPTION
"The transmit clock is derived from
received clock on ISDN Primary Rate
interfaces."
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"Facilities Data Link usage on T1 ISDN
Primary Rate interfaces.
Note: Eventually dsx1Att-54016(4) is to be
used here since the line type is ESF."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization
is not required."
::= { ds1Compliances 2 }
ds1MibE1PriCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Compliance statement for using this MIB for ISDN
Primary Rate interfaces on E1 lines."
MODULE
MANDATORY-GROUPS { ds1NearEndConfigGroup,
ds1NearEndStatisticsGroup }
OBJECT dsx1LineType
SYNTAX INTEGER {
dsx1E1CRC(5)
}
MIN-ACCESS read-only
Nicklass Standards Track [Page 62]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
DESCRIPTION
"Line type for E1 ISDN Primary Rate
interfaces."
OBJECT dsx1LineCoding
SYNTAX INTEGER {
dsx1HDB3(3)
}
MIN-ACCESS read-only
DESCRIPTION
"Type of Zero Code Suppression for
E1 ISDN Primary Rate interfaces."
OBJECT dsx1SignalMode
SYNTAX INTEGER {
messageOriented(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Signaling on E1 ISDN Primary Rate interfaces
is always message oriented."
OBJECT dsx1TransmitClockSource
SYNTAX INTEGER {
loopTiming(1)
}
MIN-ACCESS read-only
DESCRIPTION
"The transmit clock is derived from received
clock on ISDN Primary Rate interfaces."
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"Facilities Data Link usage on E1 ISDN
Primary Rate interfaces.
Note: There is a 'M-Channel' in E1,
using National Bit Sa4 (G704,
Table 4a). It is used to implement
management features between ET
and NT. This is different to
FDL in T1, which is used to carry
control signals and performance
data. In E1, control and status
signals are carried using National
Bits Sa5, Sa6 and A (RAI Ind.).
This indicates that only the other(1) or
eventually the dsx1Fdl-none(8) bits should
Nicklass Standards Track [Page 63]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
be set in this object for E1 PRI."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization is not
required."
::= { ds1Compliances 3 }
ds1Ds2Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for using this MIB for DS2
interfaces."
MODULE
MANDATORY-GROUPS { ds1DS2Group }
OBJECT dsx1LineType
SYNTAX INTEGER {
dsx1DS2M12(10),
dsx1E2(11)
}
MIN-ACCESS read-only
DESCRIPTION
"Line type for DS2, E2
interfaces."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization is not
required."
::= { ds1Compliances 4 }
ds1NCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for T1 and E1
interfaces."
MODULE -- this module
MANDATORY-GROUPS { ds1NearEndConfigurationGroup,
ds1NearEndStatisticsGroup }
GROUP ds1FarEndGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS1 Interface."
Nicklass Standards Track [Page 64]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
GROUP ds1NearEndOptionalTrapGroup
DESCRIPTION
"Implementation of this group is optional for all
systems that attach to a DS1 Interface. If it is
implemented then ds1NearEndOptionalConfigGroup
should also be implemented."
GROUP ds1NearEndOptionalConfigGroup
DESCRIPTION
"Implementation of this group is recommended for
all systems that attach to a DS1 Interface and
implement ds1NearEndOptionalTrapGroup."
GROUP ds1DS2Group
DESCRIPTION
"Implementation of this group is mandatory for all
systems that attach to a DS2 Interface."
GROUP ds1TransStatsGroup
DESCRIPTION
"This group is the set of statistics appropriate
for all systems which attach to a DS1 Interface
running transparent or unFramed lineType."
GROUP ds1ChanMappingGroup
DESCRIPTION
"This group is the set of objects for mapping a
DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex.
Implementation of this group is mandatory for
systems which support the channelization of DS3s
into DS1s."
OBJECT dsx1LineType
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line type is not
required."
OBJECT dsx1LineCoding
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line coding is not
required."
OBJECT dsx1SendCode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the send code is not
Nicklass Standards Track [Page 65]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
required."
OBJECT dsx1LoopbackConfig
MIN-ACCESS read-only
DESCRIPTION
"The ability to set loopbacks is not required."
OBJECT dsx1SignalMode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the signal mode is not
required."
OBJECT dsx1TransmitClockSource
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the transmit clock source is
not required."
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the FDL is not required."
OBJECT dsx1LineLength
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the line length is not
required."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization is not
required."
OBJECT dsx1LineMode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line Mode is not
required."
OBJECT dsx1LineBuildOut
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line build out is not
required."
::= { ds1Compliances 5 }
Nicklass Standards Track [Page 66]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ds1MibT1PriNCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for using this MIB for ISDN
Primary Rate interfaces on T1 lines."
MODULE
MANDATORY-GROUPS { ds1NearEndConfigurationGroup,
ds1NearEndStatisticsGroup }
OBJECT dsx1LineType
SYNTAX INTEGER {
dsx1ESF(2) -- Intl Spec would be G704(2)
-- or I.431(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Line type for T1 ISDN Primary Rate
interfaces."
OBJECT dsx1LineCoding
SYNTAX INTEGER {
dsx1B8ZS(2)
}
MIN-ACCESS read-only
DESCRIPTION
"Type of Zero Code Suppression for
T1 ISDN Primary Rate interfaces."
OBJECT dsx1SignalMode
SYNTAX INTEGER {
none(1), -- if there is no signaling channel
messageOriented(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Possible signaling modes for
T1 ISDN Primary Rate interfaces."
OBJECT dsx1TransmitClockSource
SYNTAX INTEGER {
loopTiming(1)
}
MIN-ACCESS read-only
DESCRIPTION
"The transmit clock is derived from
received clock on ISDN Primary Rate
interfaces."
Nicklass Standards Track [Page 67]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"Facilities Data Link usage on T1 ISDN
Primary Rate interfaces.
Note: Eventually dsx1Att-54016(4) is to be
used here since the line type is ESF."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization
is not required."
OBJECT dsx1LineMode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line Mode is not
required."
OBJECT dsx1LineBuildOut
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line build out is not
required."
::= { ds1Compliances 6 }
ds1MibE1PriNCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for using this MIB for ISDN
Primary Rate interfaces on E1 lines."
MODULE
MANDATORY-GROUPS { ds1NearEndConfigurationGroup,
ds1NearEndStatisticsGroup }
OBJECT dsx1LineType
SYNTAX INTEGER {
dsx1E1CRC(5)
}
MIN-ACCESS read-only
DESCRIPTION
"Line type for E1 ISDN Primary Rate
interfaces."
OBJECT dsx1LineCoding
SYNTAX INTEGER {
dsx1HDB3(3)
Nicklass Standards Track [Page 68]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
}
MIN-ACCESS read-only
DESCRIPTION
"Type of Zero Code Suppression for
E1 ISDN Primary Rate interfaces."
OBJECT dsx1SignalMode
SYNTAX INTEGER {
messageOriented(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Signaling on E1 ISDN Primary Rate interfaces
is always message oriented."
OBJECT dsx1TransmitClockSource
SYNTAX INTEGER {
loopTiming(1)
}
MIN-ACCESS read-only
DESCRIPTION
"The transmit clock is derived from received
clock on ISDN Primary Rate interfaces."
OBJECT dsx1Fdl
MIN-ACCESS read-only
DESCRIPTION
"Facilities Data Link usage on E1 ISDN
Primary Rate interfaces.
Note: There is a 'M-Channel' in E1,
using National Bit Sa4 (G704,
Table 4a). It is used to implement
management features between ET
and NT. This is different to
FDL in T1, which is used to carry
control signals and performance
data. In E1, control and status
signals are carried using National
Bits Sa5, Sa6 and A (RAI Ind.).
This indicates that only the other(1) or
eventually the dsx1Fdl-none(8) bits should
be set in this object for E1 PRI."
OBJECT dsx1Channelization
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the channelization is not
required."
Nicklass Standards Track [Page 69]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
OBJECT dsx1LineMode
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line Mode is not required."
OBJECT dsx1LineBuildOut
MIN-ACCESS read-only
DESCRIPTION
"The ability to set the Line build out is not
required."
::= { ds1Compliances 7 }
-- units of conformance
ds1NearEndConfigGroup OBJECT-GROUP
OBJECTS { dsx1LineIndex,
dsx1TimeElapsed,
dsx1ValidIntervals,
dsx1LineType,
dsx1LineCoding,
dsx1SendCode,
dsx1CircuitIdentifier,
dsx1LoopbackConfig,
dsx1LineStatus,
dsx1SignalMode,
dsx1TransmitClockSource,
dsx1Fdl,
dsx1InvalidIntervals,
dsx1LineLength,
dsx1LoopbackStatus,
dsx1Ds1ChannelNumber,
dsx1Channelization }
STATUS deprecated
DESCRIPTION
"A collection of objects providing configuration
information applicable to all DS1 interfaces."
::= { ds1Groups 1 }
ds1NearEndStatisticsGroup OBJECT-GROUP
OBJECTS { dsx1CurrentIndex,
dsx1CurrentESs,
dsx1CurrentSESs,
dsx1CurrentSEFSs,
dsx1CurrentUASs,
dsx1CurrentCSSs,
dsx1CurrentPCVs,
dsx1CurrentLESs,
dsx1CurrentBESs,
Nicklass Standards Track [Page 70]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1CurrentDMs,
dsx1CurrentLCVs,
dsx1IntervalIndex,
dsx1IntervalNumber,
dsx1IntervalESs,
dsx1IntervalSESs,
dsx1IntervalSEFSs,
dsx1IntervalUASs,
dsx1IntervalCSSs,
dsx1IntervalPCVs,
dsx1IntervalLESs,
dsx1IntervalBESs,
dsx1IntervalDMs,
dsx1IntervalLCVs,
dsx1IntervalValidData,
dsx1TotalIndex,
dsx1TotalESs,
dsx1TotalSESs,
dsx1TotalSEFSs,
dsx1TotalUASs,
dsx1TotalCSSs,
dsx1TotalPCVs,
dsx1TotalLESs,
dsx1TotalBESs,
dsx1TotalDMs,
dsx1TotalLCVs }
STATUS current
DESCRIPTION
"A collection of objects providing statistics
information applicable to all DS1 interfaces."
::= { ds1Groups 2 }
ds1FarEndGroup OBJECT-GROUP
OBJECTS { dsx1FarEndCurrentIndex,
dsx1FarEndTimeElapsed,
dsx1FarEndValidIntervals,
dsx1FarEndCurrentESs,
dsx1FarEndCurrentSESs,
dsx1FarEndCurrentSEFSs,
dsx1FarEndCurrentUASs,
dsx1FarEndCurrentCSSs,
dsx1FarEndCurrentLESs,
dsx1FarEndCurrentPCVs,
dsx1FarEndCurrentBESs,
dsx1FarEndCurrentDMs,
dsx1FarEndInvalidIntervals,
dsx1FarEndIntervalIndex,
dsx1FarEndIntervalNumber,
Nicklass Standards Track [Page 71]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1FarEndIntervalESs,
dsx1FarEndIntervalSESs,
dsx1FarEndIntervalSEFSs,
dsx1FarEndIntervalUASs,
dsx1FarEndIntervalCSSs,
dsx1FarEndIntervalLESs,
dsx1FarEndIntervalPCVs,
dsx1FarEndIntervalBESs,
dsx1FarEndIntervalDMs,
dsx1FarEndIntervalValidData,
dsx1FarEndTotalIndex,
dsx1FarEndTotalESs,
dsx1FarEndTotalSESs,
dsx1FarEndTotalSEFSs,
dsx1FarEndTotalUASs,
dsx1FarEndTotalCSSs,
dsx1FarEndTotalLESs,
dsx1FarEndTotalPCVs,
dsx1FarEndTotalBESs,
dsx1FarEndTotalDMs }
STATUS current
DESCRIPTION
"A collection of objects providing remote
configuration and statistics information."
::= { ds1Groups 3 }
ds1DeprecatedGroup OBJECT-GROUP
OBJECTS { dsx1IfIndex,
dsx1FracIndex,
dsx1FracNumber,
dsx1FracIfIndex }
STATUS deprecated
DESCRIPTION
"A collection of obsolete objects that may be
implemented for backwards compatibility."
::= { ds1Groups 4 }
ds1NearEndOptionalConfigGroup OBJECT-GROUP
OBJECTS { dsx1LineStatusLastChange,
dsx1LineStatusChangeTrapEnable }
STATUS current
DESCRIPTION
"A collection of objects that may be implemented
on DS1 and DS2 interfaces."
::= { ds1Groups 5 }
ds1DS2Group OBJECT-GROUP
OBJECTS { dsx1LineIndex,
Nicklass Standards Track [Page 72]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
dsx1LineType,
dsx1LineCoding,
dsx1SendCode,
dsx1LineStatus,
dsx1SignalMode,
dsx1TransmitClockSource,
dsx1Channelization }
STATUS current
DESCRIPTION
"A collection of objects providing information
about DS2 (6,312 kbps) and E2 (8,448 kbps)
systems."
::= { ds1Groups 6 }
ds1TransStatsGroup OBJECT-GROUP
OBJECTS { dsx1CurrentESs,
dsx1CurrentSESs,
dsx1CurrentUASs,
dsx1IntervalESs,
dsx1IntervalSESs,
dsx1IntervalUASs,
dsx1TotalESs,
dsx1TotalSESs,
dsx1TotalUASs }
STATUS current
DESCRIPTION
"A collection of objects which are the
statistics which can be collected from a ds1
interface that is running transparent or unframed
lineType. Statistics not in this list should
return noSuchInstance."
::= { ds1Groups 7 }
ds1NearEndOptionalTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS { dsx1LineStatusChange }
STATUS current
DESCRIPTION
"A collection of notifications that may be
implemented on DS1 and DS2 interfaces."
::= { ds1Groups 8 }
ds1ChanMappingGroup OBJECT-GROUP
OBJECTS { dsx1ChanMappedIfIndex }
STATUS current
DESCRIPTION
"A collection of objects that give an mapping of
DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex."
::= { ds1Groups 9 }
Nicklass Standards Track [Page 73]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
ds1NearEndConfigurationGroup OBJECT-GROUP
OBJECTS { dsx1LineIndex,
dsx1TimeElapsed,
dsx1ValidIntervals,
dsx1LineType,
dsx1LineCoding,
dsx1SendCode,
dsx1CircuitIdentifier,
dsx1LoopbackConfig,
dsx1LineStatus,
dsx1SignalMode,
dsx1TransmitClockSource,
dsx1Fdl,
dsx1InvalidIntervals,
dsx1LineLength,
dsx1LoopbackStatus,
dsx1Ds1ChannelNumber,
dsx1Channelization,
dsx1LineMode,
dsx1LineBuildOut }
STATUS current
DESCRIPTION
"A collection of objects providing configuration
information applicable to all DS1 interfaces."
::= { ds1Groups 10 }
END
4. Acknowledgments
This document was produced by the AToM MIB Working Group. The Editor
would like to dedicate a special thanks to C. Mike Heard for
providing a top notch doctor review and many helpful suggestions, and
to acknowledge D. Fowler, Editor of RFC 2495, F. Baker and J. Watt
Editors of RFC 1406.
5. Security Considerations
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-write. Such objects may be
considered sensitive or vulnerable in some network environments. The
support for SET operations in a non-secure environment without proper
protection can have a negative effect on network operations. The
specific objects and their sensitivities/vulnerabilities are as
follows.
Nicklass Standards Track [Page 74]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Setting the following objects to incorrect values may result in
traffic interruptions:
dsx1LineType
dsx1LineCoding
dsx1SendCode
dsx1LoopbackConfig
dsx1SignalMode
dsx1TransmitClockSource
dsx1Fdl
dsx1LineLength
dsx1Channelization
dsx1LineMode
dsx1LineBuildOut
In the case of dsx1LineType, for example, both ends of a DS1/E1 must
have the same value in order for traffic to flow. In the case of
dsx1SendCode and dsx1LoopbackConfig, for another example, traffic may
stop transmitting when particular loopbacks are applied.
Setting the following object to an incorrect value will not harm the
traffic, but it may cause a circuit to be mis-identified and thereby
create difficulties for service personnel when attempting to
troubleshoot a problem:
dsx1CircuitIdentifier
Setting the following object can cause an increase in the number of
traps received by the network management station:
dsx1LineStatusChangeTrapEnable
The readable objects in this MIB module (i.e., the objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive in
some environments since, collectively, they provide extensive
information about the performance of interfaces in DS1/E1/DS2/E2
equipment or networks and can reveal some aspects of their
configuration. In such environments, it is important to control even
GET and NOTIFY access to these objects and possibly to encrypt the
values of these objects when sending them over the network via SNMP.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPSec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
Nicklass Standards Track [Page 75]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
including full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
6. References
6.1. Normative References
[RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Structure of Management Information Version 2
(SMIv2)", STD 58, RFC 2578, April 1999.
[RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Textual Conventions for SMIv2", STD 58, RFC 2579,
April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces
Group MIB", RFC 2863, June 2000.
[AT&T-TR-54016] AT&T Technical Reference, Requirements for
Interfacing Digital Terminal Equipment to Services
Employing the Extended Superframe Format, Publication
54016, May 1988.
[ANSI-T1.403] American National Standard for Telecommunications --
Carrier-to-Customer Installation - DS1 Metallic
Interface, T1.403, February 1989.
[CCITT-G.703] CCITT Specifications Volume III, Recommendation
G.703, Physical/Electrical Characteristics of
Hierarchical Digital Interfaces, April 1991.
[ITU-T-G.704] ITU-T G.704: Synchronous frame structures used at
1544, 6312, 2048, 8488 and 44 736 kbit/s Hierarchical
Levels, July 1995.
Nicklass Standards Track [Page 76]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
[ANSI-T1.231] American National Standard for Telecommunications --
Digital Hierarchy -- Layer 1 In-Service Digital
Transmission Performance Monitoring, T1.231, Sept
1993.
[CCITT-O.162] CCITT Specifications Volume IV, Recommendation O.162,
Equipment To Perform In Service Monitoring On 2048
kbit/s Signals, July 1988.
[CCITT-G.821] CCITT Specifications Volume III, Recommendation
G.821, Error Performance Of An International Digital
Connection Forming Part Of An Integrated Services
Digital Network, July 1988.
[AT&T-TR-62411] AT&T Technical Reference, Technical Reference 62411,
ACCUNET T1.5 Service Description And Interface
Specification, December 1990.
[CCITT-G.706] CCITT Specifications Volume III, Recommendation
G.706, Frame Alignment and Cyclic Redundancy Check
(CRC) Procedures Relating to Basic Frame Structures
Defined in Recommendation G.704, July 1988.
[CCITT-G.732] CCITT Specifications Volume III, Recommendation
G.732, Characteristics Of Primary PCM Multiplex
Equipment Operating at 2048 kbit/s, July 1988.
[ITU-T-G.775] ITU-T G.775: Loss of signal (LOS) and alarm
indication signal (AIS) defect detection and
clearance criteria, May 1995.
[ITU-T-G.826] ITU-T G.826: Error performance parameters and
objectives for international, constant bit rate
digital paths at or above the primary rate, November
1993.
[ANSI-T1.107] American National Standard for Telecommunications --
Digital Hierarchy - Format Specifications, T1.107,
August 1988.
[RFC3593] Tesink, K., Ed., "Textual Conventions for MIB Modules
Using Performance History Based on 15 Minute
Intervals", RFC 3593, September 2003.
[ITU-T-M.1400] ITU-T M.1400: Designation For Interconnections Among
Network Operators, October 2001.
Nicklass Standards Track [Page 77]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
6.2. Informative References
[RFC1213] McCloghrie, K. and M. Rose, "Management Information
Base for Network Management of TCP/IP-based
internets: MIB-II", STD 17, RFC 1213, March 1991.
[RFC2494] Fowler, D., "Definitions of Managed Objects for the
DS0 and DS0 Bundle Interface Type", RFC 2494, January
1999.
[RFC2495] Fowler, D., Ed., "Definitions of Managed Objects for
the DS1, E1, DS2 and E1 Interface Types", RFC 2495,
January 1999.
[RFC1406] Baker, F. and J. Watt, Eds., "Definitions of Managed
Objects for the DS1 and E1 Interface Types", RFC
1406, January 1993.
[AT&T-UM-305] AT&T Information Systems, AT&T ESF DS1 Channel
Service Unit User's Manual, 999-100-305, February
1988.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for
Internet-Standard Management Framework", RFC 3410,
December 2002.
[RFC3592] Tesink, K., "Definitions of Managed Objects for the
Synchronous Optical Network/Synchronous Digital
Hierarchy (SONET/SDH) Interface Type", RFC 3592,
September 2003.
[RFC3896] Nicklass, O., Ed., "Definitions of Managed Objects
for the DS3/E3 Interface Types", RFC 3896, September
2004.
Nicklass Standards Track [Page 78]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Appendix A - Use of dsx1IfIndex and dsx1LineIndex
This Appendix exists to document the previous use if dsx1IfIndex and
dsx1LineIndex and to clarify the relationship of dsx1LineIndex as
defined in RFC 1406 with the dsx1LineIndex as defined in this
document.
The following shows the old and new definitions and the relationship:
[New Definition]: "This object should be made equal to ifIndex. The
next paragraph describes its previous usage. Making the object equal
to ifIndex allows proper use of ifStackTable and ds0/ds0bundle mibs.
[Old Definition]: "This object is the identifier of a DS1 Interface
on a managed device. If there is an ifEntry that is directly
associated with this and only this DS1 interface, it should have the
same value as ifIndex. Otherwise, number the dsx1LineIndices with an
unique identifier following the rules of choosing a number that is
greater than ifNumber and numbering the inside interfaces (e.g.,
equipment side) with even numbers and outside interfaces (e.g.,
network side) with odd numbers."
When the "Old Definition" was created, it was described this way to
allow a manager to treat the value _as if_ it were and ifIndex, i.e.,
the value would either be: 1) an ifIndex value or 2) a value that was
guaranteed to be different from all valid ifIndex values.
The new definition is a subset of that definition, i.e., the value is
always an ifIndex value.
The following is Section 3.1 from RFC 1406:
Different physical configurations for the support of SNMP with DS1
equipment exist. To accommodate these scenarios, two different
indices for DS1 interfaces are introduced in this MIB. These indices
are dsx1IfIndex and dsx1LineIndex.
External interface scenario: the SNMP Agent represents all managed
DS1 lines as external interfaces (for example, an Agent residing on
the device supporting DS1 interfaces directly):
For this scenario, all interfaces are assigned an integer value equal
to ifIndex, and the following applies:
ifIndex=dsx1IfIndex=dsx1LineIndex for all interfaces.
Nicklass Standards Track [Page 79]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
The dsx1IfIndex column of the DS1 Configuration table relates each
DS1 interface to its corresponding interface (ifIndex) in the
Internet-standard MIB (MIB-II STD 17, RFC 1213) [RFC1213].
External&Internal interface scenario: the SNMP Agents resides on an
host external from the device supporting DS1 interfaces (e.g., a
router). The Agent represents both the host and the DS1 device. The
index dsx1LineIndex is used to not only represent the DS1 interfaces
external from the host/DS1-device combination, but also the DS1
interfaces connecting the host and the DS1 device. The index
dsx1IfIndex is always equal to ifIndex.
Example:
A shelf full of CSUs connected to a Router. An SNMP Agent residing
on the router proxies for itself and the CSU. The router has also an
Ethernet interface:
+-----+
| | |
| | | +---------------------+
|E | | 1.544 MBPS | Line#A | DS1 Link
|t | R |---------------+ - - - - - - - - - +------>
|h | | | |
|e | O | 1.544 MBPS | Line#B | DS1 Link
|r | |---------------+ - - - - - - - - - - +------>
|n | U | | CSU Shelf |
|e | | 1.544 MBPS | Line#C | DS1 Link
|t | T |---------------+ - - - -- -- - - - - +------>
| | | | |
|-----| E | 1.544 MBPS | Line#D | DS1 Link
| | |---------------+ - - - - -- - - - - +------>
| | R | |_____________________|
| | |
| +-----+
The assignment of the index values could for example be:
ifIndex (= dsx1IfIndex) dsx1LineIndex
1 NA NA (Ethernet)
2 Line#A Router Side 6
2 Line#A Network Side 7
3 Line#B Router Side 8
3 Line#B Network Side 9
4 Line#C Router Side 10
4 Line#C Network Side 11
5 Line#D Router Side 12
5 Line#D Network Side 13
Nicklass Standards Track [Page 80]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
For this example, ifNumber is equal to 5. Note the following
description of dsx1LineIndex: the dsx1LineIndex identifies a DS1
Interface on a managed device. If there is an ifEntry that is
directly associated with this and only this DS1 interface, it should
have the same value as ifIndex. Otherwise, number the
dsx1LineIndices with an unique identifier following the rules of
choosing a number greater than ifNumber and numbering inside
interfaces (e.g., equipment side) with even numbers and outside
interfaces (e.g., network side) with odd numbers.
If the CSU shelf is managed by itself by a local SNMP Agent, the
situation would be:
ifIndex (= dsx1IfIndex) dsx1LineIndex
1 Line#A Network Side 1
2 Line#A RouterSide 2
3 Line#B Network Side 3
4 Line#B RouterSide 4
5 Line#C Network Side 5
6 Line#C Router Side 6
7 Line#D Network Side 7
8 Line#D Router Side 8
Appendix B - The delay approach to Unavailable Seconds.
This procedure is illustrated below for a DS1 ESF interface. Similar
rules would apply for other DS1, DS2, and E1 interface variants. The
procedure guarantees that the statistical counters are correctly
updated at all times, although they lag real time by 10 seconds. At
the end of each 15 minutes interval the current interval counts are
transferred to the most recent interval entry and each interval is
shifted up by one position, with the oldest being discarded if
necessary in order to make room. The current interval counts then
start over from zero. Note, however, that the signal state
calculation does not start afresh at each interval boundary; rather,
signal state information is retained across interval boundaries.
Nicklass Standards Track [Page 81]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
+---------------------------------------------------------------------+
| READ COUNTERS & STATUS INFO FROM HARDWARE |
| |
| BPV EXZ LOS FE CRC CS AIS SEF OOF LOF RAI G1-G6 SE FE LV SL |
+---------------------------------------------------------------------+
| | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | |
V V V V V V V V V V V V V V V V
+---------------------------------------------------------------------+
| ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE |
| |
| |<---------- NEAR END ----------->| |<-------- FAR END ------>| |
| |
| LCV LES PCV ES CSS BES SES SEFS A/U PCV ES CSS BES SES SEFS A/U |
+---------------------------------------------------------------------+
| | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | |
V V V V V V V V | V V V V V V |
+------------------------------+ | +----------------------+ |
| ONE-SEC DELAY | | | ONE-SEC DELAY | |
| (1 OF 10) | | | (1 OF 10) | |
+------------------------------+ | +----------------------+ |
| | | | | | | | | | | | | | | |
/ / / / / / / / / / / / / / / /
| | | | | | | | | | | | | | | |
V V V V V V V V | V V V V V V |
+------------------------------+ | +----------------------+ |
| ONE-SEC DELAY | | | ONE-SEC DELAY | |
| (10 OF 10) | | | (10 OF 10) | |
+------------------------------+ | +----------------------+ |
| | | | | | | | | | | | | | | |
V V V V V V V V V V V V V V V V
+---------------------------------------------------------------------+
| UPDATE STATISTICS COUNTERS |
| |
|<-------------- NEAR END ----------->| |<--------- FAR END---------> |
| |
|LCV LES PCV ES CSS BES SES SEFS UAS DM PCV ES CSS BES SES SEFS UAS DM|
+---------------------------------------------------------------------+
Note that if such a procedure is adopted there is no current interval
data for the first ten seconds after a system comes up.
noSuchInstance must be returned if a management station attempts to
access the current interval counters during this time.
It is an implementation-specific matter whether an agent assumes that
the initial state of the interface is available or unavailable.
Nicklass Standards Track [Page 82]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Author's Address
Orly Nicklass (editor)
RAD Data Communications, Ltd.
Ziv Tower, 24 Roul Walenberg
Tel Aviv, Israel, 69719
Phone: 9723-765-9969
EMail: orly_n@rad.com
Nicklass Standards Track [Page 83]
^L
RFC 3895 DS1/E1/DS2/E2 MIB September 2004
Full Copyright Statement
Copyright (C) The Internet Society (2004). This document is subject
to the rights, licenses and restrictions contained in BCP 78, and
except as set forth therein, the authors retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at ietf-
ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Nicklass Standards Track [Page 84]
^L
|