1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
|
Network Working Group T. Nadeau, Ed.
Request for Comment: 4802 Cisco Systems, Inc.
Category: Standards Track A. Farrel, Ed.
Old Dog Consulting
February 2007
Generalized Multiprotocol Label Switching (GMPLS)
Traffic Engineering Management Information Base
Status of This Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The IETF Trust (2007).
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes managed objects for Generalized
Multiprotocol Label Switching (GMPLS)-based traffic engineering.
Nadeau & Farrel Standards Track [Page 1]
^L
RFC 4802 GMPLS TE MIB February 2007
Table of Contents
1. Introduction ....................................................2
1.1. Migration Strategy .........................................3
2. Terminology .....................................................3
3. The Internet-Standard Management Framework ......................4
4. Outline .........................................................4
4.1. Summary of GMPLS Traffic Engineering MIB Module ............4
5. Brief Description of GMPLS TE MIB Objects .......................5
5.1. gmplsTunnelTable ...........................................5
5.2. gmplsTunnelHopTable ........................................6
5.3. gmplsTunnelARHopTable ......................................6
5.4. gmplsTunnelCHopTable .......................................6
5.5. gmplsTunnelErrorTable ......................................6
5.6. gmplsTunnelReversePerfTable ................................6
5.7. Use of 32-bit and 64-bit Counters ..........................7
6. Cross-referencing to the gmplsLabelTable ........................7
7. Example of GMPLS Tunnel Setup ...................................8
8. GMPLS Traffic Engineering MIB Module ...........................11
9. Security Considerations ........................................47
10. Acknowledgments ...............................................48
11. IANA Considerations ...........................................49
11.1. IANA Considerations for GMPLS-TE-STD-MIB .................49
11.2. Dependence on IANA MIB Modules ...........................49
11.2.1. IANA-GMPLS-TC-MIB Definition ......................50
12. References ....................................................56
12.1. Normative References .....................................56
12.2. Informative References ...................................58
1. Introduction
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in the Internet community.
In particular, it describes managed objects for modeling Generalized
Multiprotocol Label Switching (GMPLS) [RFC3945] based traffic
engineering (TE). The tables and objects defined in this document
extend those defined in the equivalent document for MPLS traffic
engineering [RFC3812], and management of GMPLS traffic engineering is
built on management of MPLS traffic engineering.
The MIB modules in this document should be used in conjunction with
the companion document [RFC4803] for GMPLS-based traffic engineering
configuration and management.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in BCP 14, [RFC2119].
Nadeau & Farrel Standards Track [Page 2]
^L
RFC 4802 GMPLS TE MIB February 2007
1.1. Migration Strategy
MPLS-TE Label Switched paths (LSPs) may be modeled and managed using
the MPLS-TE-STD-MIB module [RFC3812].
Label Switching Routers (LSRs) may be migrated to model and manage
their TE LSPs using the MIB modules in this document in order to
migrate the LSRs to GMPLS support, or to take advantage of additional
MIB objects defined in these MIB modules that are applicable to
MPLS-TE.
The GMPLS TE MIB module (GMPLS-TE-STD-MIB) defined in this document
extends the MPLS-TE-STD-MIB module [RFC3812] through a series of
augmentations and sparse augmentations of the MIB tables. The only
additions are for support of GMPLS or to support the increased
complexity of MPLS and GMPLS systems.
In order to migrate from MPLS-TE-STD-MIB support to GMPLS-TE-STD-MIB
support, an implementation needs only to add support for the
additional tables and objects defined in GMPLS-TE-STD-MIB. The
gmplsTunnelLSPEncoding may be set to tunnelLspNotGmpls to allow an
MPLS-TE LSP tunnel to benefit from the additional objects and tables
of GMPLS-LSR-STD-MIB without supporting the GMPLS protocols.
The companion document for modeling and managing GMPLS-based LSRs
[RFC4803] extends the MPLS-LSR-STD-MIB module [RFC3813] with the same
intentions.
Textual conventions are defined in [RFC3811] and the IANA-GMPLS-TC-
MIB module.
2. Terminology
This document uses terminology from the MPLS architecture document
[RFC3031], from the GMPLS architecture document [RFC3945], and from
the MPLS Traffic Engineering MIB [RFC3812]. Some frequently used
terms are described next.
An explicitly routed LSP (ERLSP) is referred to as a GMPLS tunnel.
It consists of in-segment(s) and/or out-segment(s) at the
egress/ingress LSRs, each segment being associated with one GMPLS-
enabled interface. These are also referred to as tunnel segments.
Additionally, at an intermediate LSR, we model a connection as
consisting of one or more in-segments and/or one or more out-
segments. The binding or interconnection between in-segments and
out-segments is performed using a cross-connect.
Nadeau & Farrel Standards Track [Page 3]
^L
RFC 4802 GMPLS TE MIB February 2007
These segment and cross-connect objects are defined in the MPLS Label
Switching Router MIB (MPLS-LSR-STD-MIB) [RFC3813], but see also the
GMPLS Label Switching Router MIB (GMPLS-LSR-STD-MIB) [RFC4803] for
the GMPLS-specific extensions to these objects.
3. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
4. Outline
Support for GMPLS traffic-engineered tunnels requires the following
configuration.
- Setting up tunnels with appropriate MPLS configuration parameters
using [RFC3812].
- Extending the tunnel definitions with GMPLS configuration
parameters.
- Configuring loose and strict source routed tunnel hops.
These actions may need to be accompanied with corresponding actions
using [RFC3813] and [RFC4803] to establish and configure tunnel
segments, if this is done manually. Also, the in-segment and out-
segment performance tables, mplsInSegmentPerfTable and
mplsOutSegmentPerfTable [RFC3813], should be used to determine
performance of the tunnels and tunnel segments, although it should be
noted that those tables may not be appropriate for measuring
performance on some types of GMPLS links.
4.1. Summary of GMPLS Traffic Engineering MIB Module
The following tables contain MIB objects for performing the actions
listed above when they cannot be performed solely using MIB objects
defined in MPLS-TE-STD-MIB [RFC3812].
Nadeau & Farrel Standards Track [Page 4]
^L
RFC 4802 GMPLS TE MIB February 2007
- Tunnel table (gmplsTunnelTable) for providing GMPLS-specific
tunnel configuration parameters.
- Tunnel hop, actual tunnel hop, and computed tunnel hop tables
(gmplsTunnelHopTable, gmplsTunnelARHopTable, and
gmplsTunnelCHopTable) for providing additional configuration of
strict and loose source routed tunnel hops.
- Performance and error reporting tables
(gmplsTunnelReversePerfTable and gmplsTunnelErrorTable).
These tables are described in the subsequent sections.
Additionally, the GMPLS-TE-STD-MIB module contains a new
notification.
- The GMPLS Tunnel Down Notification (gmplsTunnelDown) should be
used for all GMPLS tunnels in place of the mplsTunnelDown
notification defined in [RFC3812]. An implementation must not
issue both the gmplsTunnelDown and the mplsTunnelDown
notifications for the same event. As well as indicating that a
tunnel has transitioned to operational down state, this new
notification indicates the cause of the failure.
5. Brief Description of GMPLS TE MIB Objects
The objects described in this section support the functionality
described in [RFC3473] and [RFC3472] for GMPLS tunnels. The tables
support both manually configured and signaled tunnels.
5.1. gmplsTunnelTable
The gmplsTunnelTable extends the MPLS traffic engineering MIB module
(MPLS-TE-STD-MIB [RFC3812]) to allow GMPLS tunnels to be created
between an LSR and a remote endpoint, and existing GMPLS tunnels to
be reconfigured or removed.
Note that we only support point-to-point tunnel segments, although
multipoint-to-point and point-to-multipoint connections are supported
by an LSR acting as a cross-connect.
Each tunnel can thus have one out-segment originating at an LSR
and/or one in-segment terminating at that LSR.
Three objects within this table utilize enumerations in order to map
to enumerations that are used in GMPLS signaling. In order to
protect the GMPLS-TE-STD-MIB module from changes (in particular,
extensions) to the range of enumerations supported by the signaling
Nadeau & Farrel Standards Track [Page 5]
^L
RFC 4802 GMPLS TE MIB February 2007
protocols, these MIB objects use textual conventions with values
maintained by IANA. For further details, see the IANA Considerations
section of this document.
5.2. gmplsTunnelHopTable
The gmplsTunnelHopTable is used to indicate additional parameters for
the hops, strict or loose, of a GMPLS tunnel defined in the
gmplsTunnelTable, when it is established using signaling. Multiple
tunnels may share hops by pointing to the same entry in this table.
5.3. gmplsTunnelARHopTable
The gmplsTunnelARHopTable is used to indicate the actual hops
traversed by a tunnel as reported by the signaling protocol after the
tunnel is set up. The support of this table is optional since not
all GMPLS signaling protocols support this feature.
5.4. gmplsTunnelCHopTable
The gmplsTunnelCHopTable lists the actual hops computed by a
constraint-based routing algorithm based on the gmplsTunnelHopTable.
The support of this table is optional since not all implementations
support computation of hop lists using a constraint-based routing
protocol.
5.5. gmplsTunnelErrorTable
The gmplsTunnelErrorTable provides access to information about the
last error that occurred on each tunnel known about by the MIB. It
indicates the nature of the error and when and how it was reported,
and it can give recovery advice through an admin string.
5.6. gmplsTunnelReversePerfTable
The gmplsTunnelReversePerfTable provides additional counters to
measure the performance of bidirectional GMPLS tunnels in which
packets are visible. It supplements the counters in
mplsTunnelPerfTable and augments gmplsTunnelTable.
Note that not all counters may be appropriate or available for some
types of tunnel.
Nadeau & Farrel Standards Track [Page 6]
^L
RFC 4802 GMPLS TE MIB February 2007
5.7. Use of 32-bit and 64-bit Counters
64-bit counters are provided in the GMPLS-TE-STD-MIB module for
high-speed interfaces where the use of 32-bit counters might be
impractical. The requirements on the use of 32-bit and 64-bit
counters (copied verbatim from [RFC2863]) are as follows:
For interfaces that operate at 20,000,000 (20 million) bits per
second or less, 32-bit byte and packet counters MUST be supported.
For interfaces that operate faster than 20,000,000 bits/second,
and slower than 650,000,000 bits/second, 32-bit packet counters
MUST be supported and 64-bit octet counters MUST be supported.
For interfaces that operate at 650,000,000 bits/second or faster,
64-bit packet counters AND 64-bit octet counters MUST be
supported.
6. Cross-referencing to the gmplsLabelTable
The gmplsLabelTable is found in the GMPLS-LABEL-STD-MIB module in
[RFC4803] and provides a way to model labels in a GMPLS system where
labels might not be simple 32-bit integers.
The hop tables in this document (gmplsTunnelHopTable,
gmplsTunnelCHopTable, and gmplsTunnelARHopTable) and the segment
tables in [RFC3813] (mplsInSegmentTable and mplsOutSegmentTable)
contain objects with syntax MplsLabel.
MplsLabel (defined in [RFC3811]) is a 32-bit integer that is capable
of representing any MPLS Label and most GMPLS Labels. However, some
GMPLS Labels are larger than 32 bits and may be of arbitrary length.
Furthermore, some labels that may be safely encoded in 32 bits are
constructed from multiple sub-fields. Additionally, some GMPLS
technologies support the concatenation of individual labels to
represent a data flow carried as multiple sub-flows.
These GMPLS cases require that something other than a simple 32-bit
integer be made available to represent the labels. This is achieved
through the gmplsLabelTable contained in the GMPLS-LABEL-STD-MIB
[RFC4803].
The tables in this document and [RFC3813] that include objects with
syntax MplsLabel also include companion objects that are row
pointers. If the row pointer is set to zeroDotZero (0.0), then an
object of syntax MplsLabel contains the label encoded as a 32-bit
integer. But otherwise the row pointer indicates a row in another
MIB table that includes the label. In these cases, the row pointer
may indicate a row in the gmplsLabelTable.
Nadeau & Farrel Standards Track [Page 7]
^L
RFC 4802 GMPLS TE MIB February 2007
This provides both a good way to support legacy systems that
implement MPLS-TE-STD-MIB [RFC3812], and a significant simplification
in GMPLS systems that are limited to a single, simple label type.
Note that gmplsLabelTable supports concatenated labels through the
use of a label sub-index (gmplsLabelSubindex).
7. Example of GMPLS Tunnel Setup
This section contains an example of which MIB objects should be
modified to create a GMPLS tunnel. This example shows a best effort,
loosely routed, bidirectional traffic engineered tunnel, which spans
two hops of a simple network, uses Generalized Label requests with
Lambda encoding, has label recording and shared link layer
protection. Note that these objects should be created on the "head-
end" LSR.
First in the mplsTunnelTable:
{
mplsTunnelIndex = 1,
mplsTunnelInstance = 1,
mplsTunnelIngressLSRId = 192.0.2.1,
mplsTunnelEgressLSRId = 192.0.2.2,
mplsTunnelName = "My first tunnel",
mplsTunnelDescr = "Here to there and back again",
mplsTunnelIsIf = true(1),
mplsTunnelXCPointer = mplsXCIndex.3.0.0.12,
mplsTunnelSignallingProto = none(1),
mplsTunnelSetupPrio = 0,
mplsTunnelHoldingPrio = 0,
mplsTunnelSessionAttributes = recordRoute(4),
mplsTunnelOwner = snmp(2),
mplsTunnelLocalProtectInUse = false(2),
mplsTunnelResourcePointer = mplsTunnelResourceIndex.6,
mplsTunnelInstancePriority = 1,
mplsTunnelHopTableIndex = 1,
mplsTunnelPrimaryInstance = 0,
mplsTunnelIncludeAnyAffinity = 0,
mplsTunnelIncludeAllAffinity = 0,
mplsTunnelExcludeAnyAffinity = 0,
mplsTunnelPathInUse = 1,
mplsTunnelRole = head(1),
mplsTunnelRowStatus = createAndWait(5),
}
Nadeau & Farrel Standards Track [Page 8]
^L
RFC 4802 GMPLS TE MIB February 2007
In gmplsTunnelTable(1,1,192.0.2.1,192.0.2.2):
{
gmplsTunnelUnnumIf = true(1),
gmplsTunnelAttributes = labelRecordingRequired(1),
gmplsTunnelLSPEncoding = tunnelLspLambda,
gmplsTunnelSwitchingType = lsc,
gmplsTunnelLinkProtection = shared(2),
gmplsTunnelGPid = lambda,
gmplsTunnelSecondary = false(2),
gmplsTunnelDirection = bidirectional(1)
gmplsTunnelPathComp = explicit(2),
gmplsTunnelSendPathNotifyRecipientType = ipv4(1),
gmplsTunnelSendPathNotifyRecipient = 'C0000201'H,
gmplsTunnelAdminStatusFlags = 0,
gmplsTunnelExtraParamsPtr = 0.0
}
Entries in the mplsTunnelResourceTable, mplsTunnelHopTable, and
gmplsTunnelHopTable are created and activated at this time.
In mplsTunnelResourceTable:
{
mplsTunnelResourceIndex = 6,
mplsTunnelResourceMaxRate = 0,
mplsTunnelResourceMeanRate = 0,
mplsTunnelResourceMaxBurstSize = 0,
mplsTunnelResourceRowStatus = createAndGo(4)
}
The next two instances of mplsTunnelHopEntry are used to denote the
hops this tunnel will take across the network.
The following denotes the beginning of the network, or the first hop
in our example. We have used the fictitious LSR identified by
"192.0.2.1" as our head-end router.
In mplsTunnelHopTable:
{
mplsTunnelHopListIndex = 1,
mplsTunnelPathOptionIndex = 1,
mplsTunnelHopIndex = 1,
mplsTunnelHopAddrType = ipv4(1),
mplsTunnelHopIpv4Addr = 192.0.2.1,
mplsTunnelHopIpv4PrefixLen = 9,
mplsTunnelHopType = strict(1),
mplsTunnelHopRowStatus = createAndWait(5),
}
Nadeau & Farrel Standards Track [Page 9]
^L
RFC 4802 GMPLS TE MIB February 2007
The following denotes the end of the network, or the last hop in our
example. We have used the fictitious LSR identified by "192.0.2.2"
as our tail-end router.
In mplsTunnelHopTable:
{
mplsTunnelHopListIndex = 1,
mplsTunnelPathOptionIndex = 1,
mplsTunnelHopIndex = 2,
mplsTunnelHopAddrType = ipv4(1),
mplsTunnelHopIpv4Addr = 192.0.2.2,
mplsTunnelHopIpv4PrefixLen = 9,
mplsTunnelHopType = loose(2),
mplsTunnelHopRowStatus = createAndGo(4)
}
Now an associated entry in the gmplsTunnelHopTable is created to
provide additional GMPLS hop configuration indicating that the first
hop is an unnumbered link using Explicit Forward and Reverse Labels.
An entry in the gmplsLabelTable is created first to include the
Explicit Label.
In gmplsLabelTable:
{
gmplsLabelInterface = 2,
gmplsLabelIndex = 1,
gmplsLabelSubindex = 0,
gmplsLabelType = gmplsFreeformLabel(3),
gmplsLabelFreeform = 0xFEDCBA9876543210
gmplsLabelRowStatus = createAndGo(4)
}
In gmplsTunnelHopTable(1,1,1):
{
gmplsTunnelHopLabelStatuses = forwardPresent(0)
+reversePresent(1),
gmplsTunnelHopExplicitForwardLabelPtr = gmplsLabelTable(2,1,0)
gmplsTunnelHopExplicitReverseLabelPtr = gmplsLabelTable(2,1,0)
}
The first hop is now activated:
In mplsTunnelHopTable(1,1,1):
{
mplsTunnelHopRowStatus = active(1)
}
Nadeau & Farrel Standards Track [Page 10]
^L
RFC 4802 GMPLS TE MIB February 2007
No gmplsTunnelHopEntry is created for the second hop as it contains
no special GMPLS features.
Finally, the mplsTunnelEntry is activated:
In mplsTunnelTable(1,1,192.0.2.1,192.0.2.2)
{
mplsTunnelRowStatus = active(1)
}
8. GMPLS Traffic Engineering MIB Module
This MIB module makes reference to the following documents:
[RFC2205], [RFC2578], [RFC2579], [RFC2580], [RFC3209], [RFC3411],
[RFC3471], [RFC3473], [RFC3477], [RFC3812], [RFC4001], and [RFC4202].
GMPLS-TE-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32, Counter32, Counter64, zeroDotZero, Gauge32
FROM SNMPv2-SMI -- RFC 2578
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC 2580
TruthValue, TimeStamp, RowPointer
FROM SNMPv2-TC -- RFC 2579
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB -- RFC 4001
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC 3411
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId, mplsTunnelHopListIndex,
mplsTunnelHopPathOptionIndex, mplsTunnelHopIndex,
mplsTunnelARHopListIndex, mplsTunnelARHopIndex,
mplsTunnelCHopListIndex, mplsTunnelCHopIndex,
mplsTunnelEntry,
mplsTunnelAdminStatus, mplsTunnelOperStatus,
mplsTunnelGroup, mplsTunnelScalarGroup
FROM MPLS-TE-STD-MIB -- RFC3812
IANAGmplsLSPEncodingTypeTC, IANAGmplsSwitchingTypeTC,
IANAGmplsGeneralizedPidTC, IANAGmplsAdminStatusInformationTC
FROM IANA-GMPLS-TC-MIB
mplsStdMIB
FROM MPLS-TC-STD-MIB -- RFC 3811
;
Nadeau & Farrel Standards Track [Page 11]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTeStdMIB MODULE-IDENTITY
LAST-UPDATED
"200702270000Z" -- 27 February 2007 00:00:00 GMT
ORGANIZATION
"IETF Common Control and Measurement Plane (CCAMP) Working
Group"
CONTACT-INFO
" Thomas D. Nadeau
Cisco Systems, Inc.
Email: tnadeau@cisco.com
Adrian Farrel
Old Dog Consulting
Email: adrian@olddog.co.uk
Comments about this document should be emailed directly
to the CCAMP working group mailing list at
ccamp@ops.ietf.org."
DESCRIPTION
"Copyright (C) The IETF Trust (2007). This version of
this MIB module is part of RFC 4802; see the RFC itself for
full legal notices.
This MIB module contains managed object definitions
for GMPLS Traffic Engineering (TE) as defined in:
1. Generalized Multi-Protocol Label Switching (GMPLS)
Signaling Functional Description, Berger, L. (Editor),
RFC 3471, January 2003.
2. Generalized MPLS Signaling - RSVP-TE Extensions, Berger,
L. (Editor), RFC 3473, January 2003.
"
REVISION
"200702270000Z" -- 27 February 2007 00:00:00 GMT
DESCRIPTION
"Initial version issued as part of RFC 4802."
::= { mplsStdMIB 13 }
gmplsTeNotifications OBJECT IDENTIFIER ::= { gmplsTeStdMIB 0 }
gmplsTeScalars OBJECT IDENTIFIER ::= { gmplsTeStdMIB 1 }
gmplsTeObjects OBJECT IDENTIFIER ::= { gmplsTeStdMIB 2 }
gmplsTeConformance OBJECT IDENTIFIER ::= { gmplsTeStdMIB 3 }
gmplsTunnelsConfigured OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of GMPLS tunnels configured on this device. A GMPLS
Nadeau & Farrel Standards Track [Page 12]
^L
RFC 4802 GMPLS TE MIB February 2007
tunnel is considered configured if an entry for the tunnel
exists in the gmplsTunnelTable and the associated
mplsTunnelRowStatus is active(1)."
::= { gmplsTeScalars 1 }
gmplsTunnelsActive OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of GMPLS tunnels active on this device. A GMPLS
tunnel is considered active if there is an entry in the
gmplsTunnelTable and the associated mplsTunnelOperStatus for the
tunnel is up(1)."
::= { gmplsTeScalars 2 }
gmplsTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The gmplsTunnelTable sparsely extends the mplsTunnelTable of
MPLS-TE-STD-MIB. It allows GMPLS tunnels to be created between
an LSR and a remote endpoint, and existing tunnels to be
reconfigured or removed.
Note that only point-to-point tunnel segments are supported,
although multipoint-to-point and point-to-multipoint
connections are supported by an LSR acting as a cross-connect.
Each tunnel can thus have one out-segment originating at this
LSR and/or one in-segment terminating at this LSR.
The row status of an entry in this table is controlled by the
mplsTunnelRowStatus in the corresponding entry in the
mplsTunnelTable. When the corresponding mplsTunnelRowStatus has
value active(1), a row in this table may not be created or
modified.
The exception to this rule is the
gmplsTunnelAdminStatusInformation object, which can be modified
while the tunnel is active."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812."
::= { gmplsTeObjects 1 }
Nadeau & Farrel Standards Track [Page 13]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelEntry OBJECT-TYPE
SYNTAX GmplsTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table in association with the corresponding
entry in the mplsTunnelTable represents a GMPLS tunnel.
An entry can be created by a network administrator via SNMP SET
commands, or in response to signaling protocol events."
INDEX {
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
}
::= { gmplsTunnelTable 1 }
GmplsTunnelEntry ::= SEQUENCE {
gmplsTunnelUnnumIf TruthValue,
gmplsTunnelAttributes BITS,
gmplsTunnelLSPEncoding IANAGmplsLSPEncodingTypeTC,
gmplsTunnelSwitchingType IANAGmplsSwitchingTypeTC,
gmplsTunnelLinkProtection BITS,
gmplsTunnelGPid IANAGmplsGeneralizedPidTC,
gmplsTunnelSecondary TruthValue,
gmplsTunnelDirection INTEGER,
gmplsTunnelPathComp INTEGER,
gmplsTunnelUpstreamNotifyRecipientType InetAddressType,
gmplsTunnelUpstreamNotifyRecipient InetAddress,
gmplsTunnelSendResvNotifyRecipientType InetAddressType,
gmplsTunnelSendResvNotifyRecipient InetAddress,
gmplsTunnelDownstreamNotifyRecipientType InetAddressType,
gmplsTunnelDownstreamNotifyRecipient InetAddress,
gmplsTunnelSendPathNotifyRecipientType InetAddressType,
gmplsTunnelSendPathNotifyRecipient InetAddress,
gmplsTunnelAdminStatusFlags IANAGmplsAdminStatusInformationTC,
gmplsTunnelExtraParamsPtr RowPointer
}
gmplsTunnelUnnumIf OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel corresponds to an unnumbered
interface represented by an entry in the interfaces group table
(the ifTable) with ifType set to mpls(166).
Nadeau & Farrel Standards Track [Page 14]
^L
RFC 4802 GMPLS TE MIB February 2007
This object is only used if mplsTunnelIsIf is set to 'true'.
If both this object and the mplsTunnelIsIf object are set to
'true', the originating LSR adds an LSP_TUNNEL_INTERFACE_ID
object to the outgoing Path message.
This object contains information that is only used by the
terminating LSR."
REFERENCE
"1. Signalling Unnumbered Links in RSVP-TE, RFC 3477."
DEFVAL { false }
::= { gmplsTunnelEntry 1 }
gmplsTunnelAttributes OBJECT-TYPE
SYNTAX BITS {
labelRecordingDesired(0)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates optional parameters for this tunnel.
These bits should be taken in addition to those defined in
mplsTunnelSessionAttributes in order to determine the full set
of options to be signaled (for example SESSION_ATTRIBUTES flags
in RSVP-TE). The following describes these bitfields:
labelRecordingDesired
This flag is set to indicate that label information should be
included when doing a route record. This bit is not valid
unless the recordRoute bit is set."
REFERENCE
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
sections 4.4.3, 4.7.1, and 4.7.2."
DEFVAL { { } }
::= { gmplsTunnelEntry 2 }
gmplsTunnelLSPEncoding OBJECT-TYPE
SYNTAX IANAGmplsLSPEncodingTypeTC
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the encoding of the LSP being requested.
A value of 'tunnelLspNotGmpls' indicates that GMPLS signaling is
not in use. Some objects in this MIB module may be of use for
MPLS signaling extensions that do not use GMPLS signaling. By
setting this object to 'tunnelLspNotGmpls', an application may
Nadeau & Farrel Standards Track [Page 15]
^L
RFC 4802 GMPLS TE MIB February 2007
indicate that only those objects meaningful in MPLS should be
examined.
The values to use are defined in the TEXTUAL-CONVENTION
IANAGmplsLSPEncodingTypeTC found in the IANA-GMPLS-TC-MIB
module."
DEFVAL { tunnelLspNotGmpls }
::= { gmplsTunnelEntry 3 }
gmplsTunnelSwitchingType OBJECT-TYPE
SYNTAX IANAGmplsSwitchingTypeTC
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the type of switching that should be performed on
a particular link. This field is needed for links that
advertise more than one type of switching capability.
The values to use are defined in the TEXTUAL-CONVENTION
IANAGmplsSwitchingTypeTC found in the IANA-GMPLS-TC-MIB module.
This object is only meaningful if gmplsTunnelLSPEncodingType
is not set to 'tunnelLspNotGmpls'."
DEFVAL { unknown }
::= { gmplsTunnelEntry 4 }
gmplsTunnelLinkProtection OBJECT-TYPE
SYNTAX BITS {
extraTraffic(0),
unprotected(1),
shared(2),
dedicatedOneToOne(3),
dedicatedOnePlusOne(4),
enhanced(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This bitmask indicates the level of link protection required. A
value of zero (no bits set) indicates that any protection may be
used. The following describes these bitfields:
extraTraffic
This flag is set to indicate that the LSP should use links
that are protecting other (primary) traffic. Such LSPs may be
preempted when the links carrying the (primary) traffic being
protected fail.
Nadeau & Farrel Standards Track [Page 16]
^L
RFC 4802 GMPLS TE MIB February 2007
unprotected
This flag is set to indicate that the LSP should not use any
link layer protection.
shared
This flag is set to indicate that a shared link layer
protection scheme, such as 1:N protection, should be used to
support the LSP.
dedicatedOneToOne
This flag is set to indicate that a dedicated link layer
protection scheme, i.e., 1:1 protection, should be used to
support the LSP.
dedicatedOnePlusOne
This flag is set to indicate that a dedicated link layer
protection scheme, i.e., 1+1 protection, should be used to
support the LSP.
enhanced
This flag is set to indicate that a protection scheme that is
more reliable than Dedicated 1+1 should be used, e.g., 4 fiber
BLSR/MS-SPRING.
This object is only meaningful if gmplsTunnelLSPEncoding is
not set to 'tunnelLspNotGmpls'."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
Functional Description, RFC 3471, section 7.1."
DEFVAL { { } }
::= { gmplsTunnelEntry 5 }
gmplsTunnelGPid OBJECT-TYPE
SYNTAX IANAGmplsGeneralizedPidTC
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the payload carried by the LSP. It is only
required when GMPLS will be used for this LSP.
The values to use are defined in the TEXTUAL-CONVENTION
IANAGmplsGeneralizedPidTC found in the IANA-GMPLS-TC-MIB module.
This object is only meaningful if gmplsTunnelLSPEncoding is not
set to 'tunnelLspNotGmpls'."
DEFVAL { unknown }
::= { gmplsTunnelEntry 6 }
Nadeau & Farrel Standards Track [Page 17]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelSecondary OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates that the requested LSP is a secondary LSP.
This object is only meaningful if gmplsTunnelLSPEncoding is not
set to 'tunnelLspNotGmpls'."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
Functional Description, RFC 3471, section 7.1."
DEFVAL { false }
::= { gmplsTunnelEntry 7 }
gmplsTunnelDirection OBJECT-TYPE
SYNTAX INTEGER {
forward(0),
bidirectional(1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether this tunnel carries forward data only (is
unidirectional) or is bidirectional.
Values of this object other than 'forward' are meaningful
only if gmplsTunnelLSPEncoding is not set to
'tunnelLspNotGmpls'."
DEFVAL { forward }
::= { gmplsTunnelEntry 8 }
gmplsTunnelPathComp OBJECT-TYPE
SYNTAX INTEGER {
dynamicFull(1), -- CSPF fully computed
explicit(2), -- fully specified path
dynamicPartial(3) -- CSPF partially computed
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value instructs the source node on how to perform path
computation on the explicit route specified by the associated
entries in the gmplsTunnelHopTable.
dynamicFull
The user specifies at least the source and
destination of the path and expects that the Constrained
Nadeau & Farrel Standards Track [Page 18]
^L
RFC 4802 GMPLS TE MIB February 2007
Shortest Path First (CSPF) will calculate the remainder
of the path.
explicit
The user specifies the entire path for the tunnel to
take. This path may contain strict or loose hops.
Evaluation of the explicit route will be performed
hop by hop through the network.
dynamicPartial
The user specifies at least the source and
destination of the path and expects that the CSPF
will calculate the remainder of the path. The path
computed by CSPF is allowed to be only partially
computed allowing the remainder of the path to be
filled in across the network.
When an entry is present in the gmplsTunnelTable for a
tunnel, gmplsTunnelPathComp MUST be used and any
corresponding mplsTunnelHopEntryPathComp object in the
mplsTunnelHopTable MUST be ignored and SHOULD not be set.
mplsTunnelHopTable and mplsTunnelHopEntryPathComp are part of
MPLS-TE-STD-MIB.
This object should be ignored if the value of
gmplsTunnelLSPEncoding is 'tunnelLspNotGmpls'."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812."
DEFVAL { dynamicFull }
::= { gmplsTunnelEntry 9 }
gmplsTunnelUpstreamNotifyRecipientType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to aid in interpretation of
gmplsTunnelUpstreamNotifyRecipient."
DEFVAL { unknown }
::= { gmplsTunnelEntry 10 }
gmplsTunnelUpstreamNotifyRecipient OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
Nadeau & Farrel Standards Track [Page 19]
^L
RFC 4802 GMPLS TE MIB February 2007
"Indicates the address of the upstream recipient for Notify
messages relating to this tunnel and issued by this LSR. This
information is typically received from an upstream LSR in a Path
message.
This object is only valid when signaling a tunnel using RSVP.
It is also not valid at the head end of a tunnel since there are
no upstream LSRs to which to send a Notify message.
This object is interpreted in the context of the value of
gmplsTunnelUpstreamNotifyRecipientType. If this object is set to
0, the value of gmplsTunnelUpstreamNotifyRecipientType MUST be
set to unknown(0)."
REFERENCE
"1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 4.2. "
DEFVAL { '00000000'H } -- 0.0.0.0
::= { gmplsTunnelEntry 11 }
gmplsTunnelSendResvNotifyRecipientType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to aid in interpretation of
gmplsTunnelSendResvNotifyRecipient."
DEFVAL { unknown }
::= { gmplsTunnelEntry 12 }
gmplsTunnelSendResvNotifyRecipient OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates to an upstream LSR the address to which it should send
downstream Notify messages relating to this tunnel.
This object is only valid when signaling a tunnel using RSVP.
It is also not valid at the head end of the tunnel since no Resv
messages are sent from that LSR for this tunnel.
If set to 0, no Notify Request object will be included in the
outgoing Resv messages.
This object is interpreted in the context of the value of
gmplsTunnelSendResvNotifyRecipientType. If this object is set to
Nadeau & Farrel Standards Track [Page 20]
^L
RFC 4802 GMPLS TE MIB February 2007
0, the value of gmplsTunnelSendResvNotifyRecipientType MUST be
set to unknown(0)."
REFERENCE
"1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 4.2. "
DEFVAL { '00000000'H } -- 0.0.0.0
::= { gmplsTunnelEntry 13 }
gmplsTunnelDownstreamNotifyRecipientType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to aid in interpretation of
gmplsTunnelDownstreamNotifyRecipient."
DEFVAL { unknown }
::= { gmplsTunnelEntry 14 }
gmplsTunnelDownstreamNotifyRecipient OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the address of the downstream recipient for Notify
messages relating to this tunnel and issued by this LSR. This
information is typically received from an upstream LSR in a Resv
message. This object is only valid when signaling a tunnel using
RSVP.
It is also not valid at the tail end of a tunnel since there are
no downstream LSRs to which to send a Notify message.
This object is interpreted in the context of the value of
gmplsTunnelDownstreamNotifyRecipientType. If this object is set
to 0, the value of gmplsTunnelDownstreamNotifyRecipientType MUST
be set to unknown(0)."
REFERENCE
"1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 4.2.
"
DEFVAL { '00000000'H } -- 0.0.0.0
::= { gmplsTunnelEntry 15 }
gmplsTunnelSendPathNotifyRecipientType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
Nadeau & Farrel Standards Track [Page 21]
^L
RFC 4802 GMPLS TE MIB February 2007
"This object is used to aid in interpretation of
gmplsTunnelSendPathNotifyRecipient."
DEFVAL { unknown }
::= { gmplsTunnelEntry 16 }
gmplsTunnelSendPathNotifyRecipient OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates to a downstream LSR the address to which it should
send upstream Notify messages relating to this tunnel.
This object is only valid when signaling a tunnel using RSVP.
It is also not valid at the tail end of the tunnel since no Path
messages are sent from that LSR for this tunnel.
If set to 0, no Notify Request object will be included in the
outgoing Path messages.
This object is interpreted in the context of the value of
gmplsTunnelSendPathNotifyRecipientType. If this object is set to
0, the value of gmplsTunnelSendPathNotifyRecipientType MUST be
set to unknown(0)."
REFERENCE
"1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 4.2. "
DEFVAL { '00000000'H } -- 0.0.0.0
::= { gmplsTunnelEntry 17 }
gmplsTunnelAdminStatusFlags OBJECT-TYPE
SYNTAX IANAGmplsAdminStatusInformationTC
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines the setting of the Admin Status flags in the
Admin Status object or TLV, as described in RFC 3471. Setting
this field to a non-zero value will result in the inclusion of
the Admin Status object on signaling messages.
The values to use are defined in the TEXTUAL-CONVENTION
IANAGmplsAdminStatusInformationTC found in the
IANA-GMPLS-TC-MIB module.
This value of this object can be modified when the
corresponding mplsTunnelRowStatus and mplsTunnelAdminStatus
is active(1). By doing so, a new signaling message will be
Nadeau & Farrel Standards Track [Page 22]
^L
RFC 4802 GMPLS TE MIB February 2007
triggered including the requested Admin Status object or
TLV."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
Functional Description, RFC 3471, section 8."
DEFVAL { { } }
::= { gmplsTunnelEntry 18 }
gmplsTunnelExtraParamsPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Some tunnels will run over transports that can usefully support
technology-specific additional parameters (for example,
Synchronous Optical Network (SONET) resource usage). Such
parameters can be supplied in an external table and referenced
from here.
A value of zeroDotzero in this attribute indicates that there
is no such additional information."
DEFVAL { zeroDotZero }
::= { gmplsTunnelEntry 19 }
gmplsTunnelHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The gmplsTunnelHopTable sparsely extends the mplsTunnelHopTable
of MPLS-TE-STD-MIB. It is used to indicate the Explicit Labels
to be used in an explicit path for a GMPLS tunnel defined in the
mplsTunnelTable and gmplsTunnelTable, when it is established
using signaling. It does not insert new hops, but does define
new values for hops defined in the mplsTunnelHopTable.
Each row in this table is indexed by the same indexes as in the
mplsTunnelHopTable. It is acceptable for some rows in the
mplsTunnelHopTable to have corresponding entries in this table
and some to have no corresponding entry in this table.
The storage type for this entry is given by the value
of mplsTunnelHopStorageType in the corresponding entry in the
mplsTunnelHopTable.
The row status of an entry in this table is controlled by
mplsTunnelHopRowStatus in the corresponding entry in the
mplsTunnelHopTable. That is, it is not permitted to create a row
Nadeau & Farrel Standards Track [Page 23]
^L
RFC 4802 GMPLS TE MIB February 2007
in this table, or to modify an existing row, when the
corresponding mplsTunnelHopRowStatus has the value active(1)."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812.
2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473.
"
::= { gmplsTeObjects 2 }
gmplsTunnelHopEntry OBJECT-TYPE
SYNTAX GmplsTunnelHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents additions to a tunnel hop
defined in mplsTunnelHopEntry. At an ingress to a tunnel, an
entry in this table is created by a network administrator for an
ERLSP to be set up by a signaling protocol. At transit and
egress nodes, an entry in this table may be used to represent the
explicit path instructions received using the signaling
protocol."
INDEX {
mplsTunnelHopListIndex,
mplsTunnelHopPathOptionIndex,
mplsTunnelHopIndex
}
::= { gmplsTunnelHopTable 1 }
GmplsTunnelHopEntry ::= SEQUENCE {
gmplsTunnelHopLabelStatuses BITS,
gmplsTunnelHopExplicitForwardLabel Unsigned32,
gmplsTunnelHopExplicitForwardLabelPtr RowPointer,
gmplsTunnelHopExplicitReverseLabel Unsigned32,
gmplsTunnelHopExplicitReverseLabelPtr RowPointer
}
gmplsTunnelHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent(0),
reversePresent(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence of labels indicated by the
gmplsTunnelHopExplicitForwardLabel or
gmplsTunnelHopExplicitForwardLabelPtr, and
gmplsTunnelHopExplicitReverseLabel or
Nadeau & Farrel Standards Track [Page 24]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelHopExplicitReverseLabelPtr objects.
For the Present bits, a set bit indicates that a label is
present for this hop in the route. This allows zero to be a
valid label value."
DEFVAL { { } }
::= { gmplsTunnelHopEntry 1 }
gmplsTunnelHopExplicitForwardLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If gmplsTunnelHopLabelStatuses object indicates that a Forward
Label is present and gmplsTunnelHopExplicitForwardLabelPtr
contains the value zeroDotZero, then the label to use on this
hop is represented by the value of this object."
::= { gmplsTunnelHopEntry 2 }
gmplsTunnelHopExplicitForwardLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the gmplsTunnelHopLabelStatuses object indicates that a
Forward Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
in the forward direction.
If the gmplsTunnelHopLabelStatuses object indicates that a
Forward Label is present and this object contains the value
zeroDotZero, then the label to use on this hop is found in the
gmplsTunnelHopExplicitForwardLabel object."
DEFVAL { zeroDotZero }
::= { gmplsTunnelHopEntry 3 }
gmplsTunnelHopExplicitReverseLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the gmplsTunnelHopLabelStatuses object indicates that a
Reverse Label is present and
gmplsTunnelHopExplicitReverseLabelPtr contains the value
zeroDotZero, then the label to use on this hop is found in
this object encoded as a 32-bit integer."
::= { gmplsTunnelHopEntry 4 }
Nadeau & Farrel Standards Track [Page 25]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelHopExplicitReverseLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the gmplsTunnelHopLabelStatuses object indicates that a
Reverse Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
in the reverse direction.
If the gmplsTunnelHopLabelStatuses object indicates that a
Reverse Label is present and this object contains the value
zeroDotZero, then the label to use on this hop is found in the
gmplsTunnelHopExplicitReverseLabel object."
DEFVAL { zeroDotZero }
::= { gmplsTunnelHopEntry 5 }
gmplsTunnelARHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The gmplsTunnelARHopTable sparsely extends the
mplsTunnelARHopTable of MPLS-TE-STD-MIB. It is used to
indicate the labels currently in use for a GMPLS tunnel
defined in the mplsTunnelTable and gmplsTunnelTable, as
reported by the signaling protocol. It does not insert
new hops, but does define new values for hops defined in
the mplsTunnelARHopTable.
Each row in this table is indexed by the same indexes as in the
mplsTunnelARHopTable. It is acceptable for some rows in the
mplsTunnelARHopTable to have corresponding entries in this table
and some to have no corresponding entry in this table.
Note that since the information necessary to build entries
within this table is not provided by some signaling protocols
and might not be returned in all cases of other signaling
protocols, implementation of this table and the
mplsTunnelARHopTable is optional. Furthermore, since the
information in this table is actually provided by the
signaling protocol after the path has been set up, the entries
in this table are provided only for observation, and hence,
all variables in this table are accessible exclusively as
read-only."
REFERENCE
"1. Extensions to RSVP for LSP Tunnels, RFC 3209.
Nadeau & Farrel Standards Track [Page 26]
^L
RFC 4802 GMPLS TE MIB February 2007
2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473.
3. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812."
::= { gmplsTeObjects 3 }
gmplsTunnelARHopEntry OBJECT-TYPE
SYNTAX GmplsTunnelARHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents additions to a tunnel hop
visible in mplsTunnelARHopEntry. An entry is created by the
signaling protocol for a signaled ERLSP set up by the signaling
protocol.
At any node on the LSP (ingress, transit, or egress), this table
and the mplsTunnelARHopTable (if the tables are supported and if
the signaling protocol is recording actual route information)
contain the actual route of the whole tunnel. If the signaling
protocol is not recording the actual route, this table MAY
report the information from the gmplsTunnelHopTable or the
gmplsTunnelCHopTable.
Note that the recording of actual labels is distinct from the
recording of the actual route in some signaling protocols. This
feature is enabled using the gmplsTunnelAttributes object."
INDEX {
mplsTunnelARHopListIndex,
mplsTunnelARHopIndex
}
::= { gmplsTunnelARHopTable 1 }
GmplsTunnelARHopEntry ::= SEQUENCE {
gmplsTunnelARHopLabelStatuses BITS,
gmplsTunnelARHopExplicitForwardLabel Unsigned32,
gmplsTunnelARHopExplicitForwardLabelPtr RowPointer,
gmplsTunnelARHopExplicitReverseLabel Unsigned32,
gmplsTunnelARHopExplicitReverseLabelPtr RowPointer,
gmplsTunnelARHopProtection BITS
}
gmplsTunnelARHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent(0),
reversePresent(1),
forwardGlobal(2),
reverseGlobal(3)
}
Nadeau & Farrel Standards Track [Page 27]
^L
RFC 4802 GMPLS TE MIB February 2007
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence and status of labels
indicated by the gmplsTunnelARHopExplicitForwardLabel or
gmplsTunnelARHopExplicitForwardLabelPtr, and
gmplsTunnelARHopExplicitReverseLabel or
gmplsTunnelARHopExplicitReverseLabelPtr objects.
For the Present bits, a set bit indicates that a label is
present for this hop in the route.
For the Global bits, a set bit indicates that the label comes
from the Global Label Space; a clear bit indicates that this is
a Per-Interface label. A Global bit only has meaning if the
corresponding Present bit is set."
::= { gmplsTunnelARHopEntry 1 }
gmplsTunnelARHopExplicitForwardLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelARHopLabelStatuses object indicates that a
Forward Label is present and
gmplsTunnelARHopExplicitForwardLabelPtr contains the value
zeroDotZero, then the label in use on this hop is found in this
object encoded as a 32-bit integer."
::= { gmplsTunnelARHopEntry 2 }
gmplsTunnelARHopExplicitForwardLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelARHopLabelStatuses object indicates that a
Forward Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label in use on this hop
in the forward direction.
If the gmplsTunnelARHopLabelStatuses object indicates that a
Forward Label is present and this object contains the value
zeroDotZero, then the label in use on this hop is found in the
gmplsTunnelARHopExplicitForwardLabel object."
::= { gmplsTunnelARHopEntry 3 }
Nadeau & Farrel Standards Track [Page 28]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelARHopExplicitReverseLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelARHopLabelStatuses object indicates that a
Reverse Label is present and
gmplsTunnelARHopExplicitReverseLabelPtr contains the value
zeroDotZero, then the label in use on this hop is found in this
object encoded as a 32-bit integer."
::= { gmplsTunnelARHopEntry 4 }
gmplsTunnelARHopExplicitReverseLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelARHopLabelStatuses object indicates that a
Reverse Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label in use on this hop
in the reverse direction.
If the gmplsTunnelARHopLabelStatuses object indicates that a
Reverse Label is present and this object contains the value
zeroDotZero, then the label in use on this hop is found in the
gmplsTunnelARHopExplicitReverseLabel object."
::= { gmplsTunnelARHopEntry 5 }
gmplsTunnelARHopProtection OBJECT-TYPE
SYNTAX BITS {
localAvailable(0),
localInUse(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability and usage of protection on the reported link.
localAvailable
This flag is set to indicate that the link downstream of this
node is protected via a local repair mechanism.
localInUse
This flag is set to indicate that a local repair mechanism is
in use to maintain this tunnel (usually in the face of an
outage of the link it was previously routed over)."
REFERENCE
Nadeau & Farrel Standards Track [Page 29]
^L
RFC 4802 GMPLS TE MIB February 2007
"1. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
section 4.4.1."
::= { gmplsTunnelARHopEntry 6 }
gmplsTunnelCHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The gmplsTunnelCHopTable sparsely extends the
mplsTunnelCHopTable of MPLS-TE-STD-MIB. It is used to indicate
additional information about the hops of a GMPLS tunnel defined
in the mplsTunnelTable and gmplsTunnelTable, as computed by a
constraint-based routing protocol, based on the
mplsTunnelHopTable and the gmplsTunnelHopTable.
Each row in this table is indexed by the same indexes as in the
mplsTunnelCHopTable. It is acceptable for some rows in the
mplsTunnelCHopTable to have corresponding entries in this table
and some to have no corresponding entry in this table.
Please note that since the information necessary to build
entries within this table may not be supported by some LSRs,
implementation of this table is optional.
Furthermore, since the information in this table is actually
provided by a path computation component after the path has been
computed, the entries in this table are provided only for
observation, and hence, all objects in this table are accessible
exclusively as read-only."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812.
2. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473."
::= { gmplsTeObjects 4 }
gmplsTunnelCHopEntry OBJECT-TYPE
SYNTAX GmplsTunnelCHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents additions to a computed tunnel
hop visible in mplsTunnelCHopEntry. An entry is created by a
path computation component based on the hops specified in the
corresponding mplsTunnelHopTable and gmplsTunnelHopTable.
At a transit LSR, this table (if the table is supported) MAY
contain the path computed by a path computation engine on (or on
Nadeau & Farrel Standards Track [Page 30]
^L
RFC 4802 GMPLS TE MIB February 2007
behalf of) the transit LSR."
INDEX {
mplsTunnelCHopListIndex,
mplsTunnelCHopIndex
}
::= { gmplsTunnelCHopTable 1 }
GmplsTunnelCHopEntry ::= SEQUENCE {
gmplsTunnelCHopLabelStatuses BITS,
gmplsTunnelCHopExplicitForwardLabel Unsigned32,
gmplsTunnelCHopExplicitForwardLabelPtr RowPointer,
gmplsTunnelCHopExplicitReverseLabel Unsigned32,
gmplsTunnelCHopExplicitReverseLabelPtr RowPointer
}
gmplsTunnelCHopLabelStatuses OBJECT-TYPE
SYNTAX BITS {
forwardPresent(0),
reversePresent(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates the presence of labels indicated by the
gmplsTunnelCHopExplicitForwardLabel or
gmplsTunnelCHopExplicitForwardLabelPtr and
gmplsTunnelCHopExplicitReverseLabel or
gmplsTunnelCHopExplicitReverseLabelPtr objects.
A set bit indicates that a label is present for this hop in the
route, thus allowing zero to be a valid label value."
::= { gmplsTunnelCHopEntry 1 }
gmplsTunnelCHopExplicitForwardLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelCHopLabelStatuses object indicates that a
Forward Label is present and
gmplsTunnelCHopExplicitForwardLabelPtr contains the value
zeroDotZero, then the label to use on this hop is found in this
object encoded as a 32-bit integer."
::= { gmplsTunnelCHopEntry 2 }
gmplsTunnelCHopExplicitForwardLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
Nadeau & Farrel Standards Track [Page 31]
^L
RFC 4802 GMPLS TE MIB February 2007
STATUS current
DESCRIPTION
"If the gmplsTunnelCHopLabelStatuses object indicates that a
Forward Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
in the forward direction.
If the gmplsTunnelCHopLabelStatuses object indicates that a
Forward Label is present and this object contains the value
zeroDotZero, then the label to use on this hop is found in the
gmplsTunnelCHopExplicitForwardLabel object."
::= { gmplsTunnelCHopEntry 3 }
gmplsTunnelCHopExplicitReverseLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelCHopLabelStatuses object indicates that a
Reverse Label is present and
gmplsTunnelCHopExplicitReverseLabelPtr contains the value
zeroDotZero, then the label to use on this hop is found in this
object encoded as a 32-bit integer."
::= { gmplsTunnelCHopEntry 4 }
gmplsTunnelCHopExplicitReverseLabelPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the gmplsTunnelCHopLabelStatuses object indicates that a
Reverse Label is present, this object contains a pointer to a
row in another MIB table (such as the gmplsLabelTable of
GMPLS-LABEL-STD-MIB) that contains the label to use on this hop
in the reverse direction.
If the gmplsTunnelCHopLabelStatuses object indicates that a
Reverse Label is present and this object contains the value
zeroDotZero, then the label to use on this hop is found in the
gmplsTunnelCHopExplicitReverseLabel object."
::= { gmplsTunnelCHopEntry 5 }
gmplsTunnelReversePerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelReversePerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Nadeau & Farrel Standards Track [Page 32]
^L
RFC 4802 GMPLS TE MIB February 2007
"This table augments the gmplsTunnelTable to provide
per-tunnel packet performance information for the reverse
direction of a bidirectional tunnel. It can be seen as
supplementing the mplsTunnelPerfTable, which augments the
mplsTunnelTable.
For links that do not transport packets, these packet counters
cannot be maintained. For such links, attempts to read the
objects in this table will return noSuchInstance.
A tunnel can be known to be bidirectional by inspecting the
gmplsTunnelDirection object."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812."
::= { gmplsTeObjects 5 }
gmplsTunnelReversePerfEntry OBJECT-TYPE
SYNTAX GmplsTunnelReversePerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for every
bidirectional GMPLS tunnel where packets are visible to the
LSR."
AUGMENTS { gmplsTunnelEntry }
::= { gmplsTunnelReversePerfTable 1 }
GmplsTunnelReversePerfEntry ::= SEQUENCE {
gmplsTunnelReversePerfPackets Counter32,
gmplsTunnelReversePerfHCPackets Counter64,
gmplsTunnelReversePerfErrors Counter32,
gmplsTunnelReversePerfBytes Counter32,
gmplsTunnelReversePerfHCBytes Counter64
}
gmplsTunnelReversePerfPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets forwarded on the tunnel in the reverse
direction if it is bidirectional.
This object represents the 32-bit value of the least
significant part of the 64-bit value if both
gmplsTunnelReversePerfHCPackets and this object are returned.
Nadeau & Farrel Standards Track [Page 33]
^L
RFC 4802 GMPLS TE MIB February 2007
For links that do not transport packets, this packet counter
cannot be maintained. For such links, this value will return
noSuchInstance."
::= { gmplsTunnelReversePerfEntry 1 }
gmplsTunnelReversePerfHCPackets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High-capacity counter for number of packets forwarded on the
tunnel in the reverse direction if it is bidirectional.
For links that do not transport packets, this packet counter
cannot be maintained. For such links, this value will return
noSuchInstance."
::= { gmplsTunnelReversePerfEntry 2 }
gmplsTunnelReversePerfErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of errored packets received on the tunnel in the reverse
direction if it is bidirectional. For links that do not
transport packets, this packet counter cannot be maintained. For
such links, this value will return noSuchInstance."
::= { gmplsTunnelReversePerfEntry 3 }
gmplsTunnelReversePerfBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes forwarded on the tunnel in the reverse direction
if it is bidirectional.
This object represents the 32-bit value of the least
significant part of the 64-bit value if both
gmplsTunnelReversePerfHCBytes and this object are returned.
For links that do not transport packets, this packet counter
cannot be maintained. For such links, this value will return
noSuchInstance."
::= { gmplsTunnelReversePerfEntry 4 }
gmplsTunnelReversePerfHCBytes OBJECT-TYPE
SYNTAX Counter64
Nadeau & Farrel Standards Track [Page 34]
^L
RFC 4802 GMPLS TE MIB February 2007
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High-capacity counter for number of bytes forwarded on the
tunnel in the reverse direction if it is bidirectional.
For links that do not transport packets, this packet counter
cannot be maintained. For such links, this value will return
noSuchInstance."
::= { gmplsTunnelReversePerfEntry 5 }
gmplsTunnelErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF GmplsTunnelErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments the mplsTunnelTable.
This table provides per-tunnel information about errors. Errors
may be detected locally or reported through the signaling
protocol. Error reporting is not exclusive to GMPLS, and this
table may be applied in MPLS systems.
Entries in this table are not persistent over system resets
or re-initializations of the management system."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering (TE)
Management Information Base (MIB), RFC 3812."
::= { gmplsTeObjects 6 }
gmplsTunnelErrorEntry OBJECT-TYPE
SYNTAX GmplsTunnelErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by the LSR for every tunnel
where error information is visible to the LSR.
Note that systems that read the objects in this table one at
a time and do not perform atomic operations to read entire
instantiated table rows at once, should, for each conceptual
column with valid data, read gmplsTunnelErrorLastTime
prior to the other objects in the row and again subsequent to
reading the last object of the row. They should verify that
the value of gmplsTunnelErrorLastTime did not change and
thereby ensure that all data read belongs to the same error
event."
Nadeau & Farrel Standards Track [Page 35]
^L
RFC 4802 GMPLS TE MIB February 2007
AUGMENTS { mplsTunnelEntry }
::= { gmplsTunnelErrorTable 1 }
GmplsTunnelErrorEntry ::= SEQUENCE {
gmplsTunnelErrorLastErrorType INTEGER,
gmplsTunnelErrorLastTime TimeStamp,
gmplsTunnelErrorReporterType InetAddressType,
gmplsTunnelErrorReporter InetAddress,
gmplsTunnelErrorCode Unsigned32,
gmplsTunnelErrorSubcode Unsigned32,
gmplsTunnelErrorTLVs OCTET STRING,
gmplsTunnelErrorHelpString SnmpAdminString
}
gmplsTunnelErrorLastErrorType OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
unknown(1),
protocol(2),
pathComputation(3),
localConfiguration(4),
localResources(5),
localOther(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nature of the last error. Provides interpretation context
for gmplsTunnelErrorProtocolCode and
gmplsTunnelErrorProtocolSubcode.
A value of noError(0) shows that there is no error associated
with this tunnel and means that the other objects in this table
entry (conceptual row) have no meaning.
A value of unknown(1) shows that there is an error but that no
additional information about the cause is known. The error may
have been received in a signaled message or generated locally.
A value of protocol(2) or pathComputation(3) indicates the
cause of an error and identifies an error that has been received
through signaling or will itself be signaled.
A value of localConfiguration(4), localResources(5) or
localOther(6) identifies an error that has been detected
by the local node but that will not be reported through
signaling."
::= { gmplsTunnelErrorEntry 1 }
Nadeau & Farrel Standards Track [Page 36]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelErrorLastTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which the last error occurred. This is presented as
the value of SysUpTime when the error occurred or was reported
to this node.
If gmplsTunnelErrorLastErrorType has the value noError(0), then
this object is not valid and should be ignored.
Note that entries in this table are not persistent over system
resets or re-initializations of the management system."
::= { gmplsTunnelErrorEntry 2 }
gmplsTunnelErrorReporterType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address type of the error reported.
This object is used to aid in interpretation of
gmplsTunnelErrorReporter."
::= { gmplsTunnelErrorEntry 3 }
gmplsTunnelErrorReporter OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address of the node reporting the last error, or the address
of the resource (such as an interface) associated with the
error.
If gmplsTunnelErrorLastErrorType has the value noError(0), then
this object is not valid and should be ignored.
If gmplsTunnelErrorLastErrorType has the value unknown(1),
localConfiguration(4), localResources(5), or localOther(6),
this object MAY contain a zero value.
This object should be interpreted in the context of the value of
the object gmplsTunnelErrorReporterType."
REFERENCE
"1. Textual Conventions for Internet Network Addresses, RFC 4001,
section 4, Usage Hints."
Nadeau & Farrel Standards Track [Page 37]
^L
RFC 4802 GMPLS TE MIB February 2007
::= { gmplsTunnelErrorEntry 4 }
gmplsTunnelErrorCode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The primary error code associated with the last error.
The interpretation of this error code depends on the value of
gmplsTunnelErrorLastErrorType. If the value of
gmplsTunnelErrorLastErrorType is noError(0), the value of this
object should be 0 and should be ignored. If the value of
gmplsTunnelErrorLastErrorType is protocol(2), the error should
be interpreted in the context of the signaling protocol
identified by the mplsTunnelSignallingProto object."
REFERENCE
"1. Resource ReserVation Protocol -- Version 1 Functional
Specification, RFC 2205, section B.
2. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
section 7.3.
3. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 13.1."
::= { gmplsTunnelErrorEntry 5 }
gmplsTunnelErrorSubcode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary error code associated with the last error and the
protocol used to signal this tunnel. This value is interpreted
in the context of the value of gmplsTunnelErrorCode.
If the value of gmplsTunnelErrorLastErrorType is noError(0), the
value of this object should be 0 and should be ignored."
REFERENCE
"1. Resource ReserVation Protocol -- Version 1 Functional
Specification, RFC 2205, section B.
2. RSVP-TE: Extensions to RSVP for LSP Tunnels, RFC 3209,
section 7.3.
3. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 13.1. "
::= { gmplsTunnelErrorEntry 6 }
gmplsTunnelErrorTLVs OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..65535))
MAX-ACCESS read-only
STATUS current
Nadeau & Farrel Standards Track [Page 38]
^L
RFC 4802 GMPLS TE MIB February 2007
DESCRIPTION
"The sequence of interface identifier TLVs reported with the
error by the protocol code. The interpretation of the TLVs and
the encoding within the protocol are described in the
references. A value of zero in the first octet indicates that no
TLVs are present."
REFERENCE
"1. Generalized MPLS Signaling - RSVP-TE Extensions, RFC 3473,
section 8.2."
::= { gmplsTunnelErrorEntry 7 }
gmplsTunnelErrorHelpString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the last error,
recovery actions, and support advice. If there is no help string,
this object contains a zero length string.
If the value of gmplsTunnelErrorLastErrorType is noError(0),
this object should contain a zero length string, but may contain
a help string indicating that there is no error."
::= { gmplsTunnelErrorEntry 8 }
--
-- Notifications
--
gmplsTunnelDown NOTIFICATION-TYPE
OBJECTS {
mplsTunnelAdminStatus,
mplsTunnelOperStatus,
gmplsTunnelErrorLastErrorType,
gmplsTunnelErrorReporterType,
gmplsTunnelErrorReporter,
gmplsTunnelErrorCode,
gmplsTunnelErrorSubcode
}
STATUS current
DESCRIPTION
"This notification is generated when an mplsTunnelOperStatus
object for a tunnel in the gmplsTunnelTable is about to enter
the down state from some other state (but not from the
notPresent state). This other state is indicated by the
included value of mplsTunnelOperStatus.
The objects in this notification provide additional error
information that indicates the reason why the tunnel has
Nadeau & Farrel Standards Track [Page 39]
^L
RFC 4802 GMPLS TE MIB February 2007
transitioned to down(2).
Note that an implementation MUST only issue one of
mplsTunnelDown and gmplsTunnelDown for any single event on a
single tunnel. If the tunnel has an entry in the
gmplsTunnelTable, an implementation SHOULD use gmplsTunnelDown
for all tunnel-down events and SHOULD NOT use mplsTunnelDown.
This notification is subject to the control of
mplsTunnelNotificationEnable. When that object is set
to false(2), then the notification must not be issued.
Further, this notification is also subject to
mplsTunnelNotificationMaxRate. That object indicates the
maximum number of notifications issued per second. If events
occur more rapidly, the implementation may simply fail to emit
some notifications during that period, or may queue them until
an appropriate time. The notification rate applies to the sum
of all notifications in the MPLS-TE-STD-MIB and
GMPLS-TE-STD-MIB modules applied across the whole of the
reporting device.
mplsTunnelOperStatus, mplsTunnelAdminStatus, mplsTunnelDown,
mplsTunnelNotificationEnable, and mplsTunnelNotificationMaxRate
objects are found in MPLS-TE-STD-MIB."
REFERENCE
"1. Multiprotocol Label Switching (MPLS) Traffic Engineering
(TE) Management Information Base (MIB), RFC 3812."
::= { gmplsTeNotifications 1 }
gmplsTeGroups
OBJECT IDENTIFIER ::= { gmplsTeConformance 1 }
gmplsTeCompliances
OBJECT IDENTIFIER ::= { gmplsTeConformance 2 }
-- Compliance requirement for fully compliant implementations.
gmplsTeModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full support for
GMPLS-TE-STD-MIB. Such devices can then be monitored and also
be configured using this MIB module.
The mandatory group has to be implemented by all LSRs that
originate, terminate, or act as transit for TE-LSPs/tunnels.
In addition, depending on the type of tunnels supported, other
Nadeau & Farrel Standards Track [Page 40]
^L
RFC 4802 GMPLS TE MIB February 2007
groups become mandatory as explained below."
MODULE MPLS-TE-STD-MIB -- The MPLS-TE-STD-MIB, RFC 3812
MANDATORY-GROUPS {
mplsTunnelGroup,
mplsTunnelScalarGroup
}
MODULE -- this module
MANDATORY-GROUPS {
gmplsTunnelGroup,
gmplsTunnelScalarGroup
}
GROUP gmplsTunnelSignaledGroup
DESCRIPTION
"This group is mandatory for devices that support signaled
tunnel set up, in addition to gmplsTunnelGroup. The following
constraints apply:
mplsTunnelSignallingProto should be at least read-only
returning a value of ldp(2) or rsvp(3)."
GROUP gmplsTunnelOptionalGroup
DESCRIPTION
"Objects in this group are optional."
GROUP gmplsTeNotificationGroup
DESCRIPTION
"This group is mandatory for those implementations that can
implement the notifications contained in this group."
::= { gmplsTeCompliances 1 }
-- Compliance requirement for read-only compliant implementations.
gmplsTeModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance requirement for implementations that only provide
read-only support for GMPLS-TE-STD-MIB. Such devices can then be
monitored but cannot be configured using this MIB module."
MODULE -- this module
-- The mandatory group has to be implemented by all LSRs that
-- originate, terminate, or act as transit for TE-LSPs/tunnels.
Nadeau & Farrel Standards Track [Page 41]
^L
RFC 4802 GMPLS TE MIB February 2007
-- In addition, depending on the type of tunnels supported, other
-- groups become mandatory as explained below.
MANDATORY-GROUPS {
gmplsTunnelGroup,
gmplsTunnelScalarGroup
}
GROUP gmplsTunnelSignaledGroup
DESCRIPTION
"This group is mandatory for devices that support signaled
tunnel set up, in addition to gmplsTunnelGroup. The following
constraints apply:
mplsTunnelSignallingProto should be at least read-only
returning a value of ldp(2) or rsvp(3)."
GROUP gmplsTunnelOptionalGroup
DESCRIPTION
"Objects in this group are optional."
GROUP gmplsTeNotificationGroup
DESCRIPTION
"This group is mandatory for those implementations that can
implement the notifications contained in this group."
OBJECT gmplsTunnelUnnumIf
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelAttributes
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelLSPEncoding
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelSwitchingType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelLinkProtection
MIN-ACCESS read-only
DESCRIPTION
Nadeau & Farrel Standards Track [Page 42]
^L
RFC 4802 GMPLS TE MIB February 2007
"Write access is not required."
OBJECT gmplsTunnelGPid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelSecondary
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelDirection
MIN-ACCESS read-only
DESCRIPTION
"Only forward(0) is required."
OBJECT gmplsTunnelPathComp
MIN-ACCESS read-only
DESCRIPTION
"Only explicit(2) is required."
OBJECT gmplsTunnelUpstreamNotifyRecipientType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION "Only unknown(0), ipv4(1), and ipv6(2) support
is required."
OBJECT gmplsTunnelUpstreamNotifyRecipient
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION "An implementation is only required to support
unknown(0), ipv4(1), and ipv6(2) sizes."
OBJECT gmplsTunnelSendResvNotifyRecipientType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION "Only unknown(0), ipv4(1), and ipv6(2) support
is required."
OBJECT gmplsTunnelSendResvNotifyRecipient
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION "An implementation is only required to support
unknown(0), ipv4(1), and ipv6(2) sizes."
OBJECT gmplsTunnelDownstreamNotifyRecipientType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
Nadeau & Farrel Standards Track [Page 43]
^L
RFC 4802 GMPLS TE MIB February 2007
MIN-ACCESS read-only
DESCRIPTION "Only unknown(0), ipv4(1), and ipv6(2) support
is required."
OBJECT gmplsTunnelDownstreamNotifyRecipient
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION "An implementation is only required to support
unknown(0), ipv4(1), and ipv6(2) sizes."
OBJECT gmplsTunnelSendPathNotifyRecipientType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION "Only unknown(0), ipv4(1), and ipv6(2) support
is required."
OBJECT gmplsTunnelSendPathNotifyRecipient
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION "An implementation is only required to support
unknown(0), ipv4(1), and ipv6(2) sizes."
OBJECT gmplsTunnelAdminStatusFlags
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelExtraParamsPtr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- gmplsTunnelHopLabelStatuses has max access read-only
OBJECT gmplsTunnelHopExplicitForwardLabel
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelHopExplicitForwardLabelPtr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT gmplsTunnelHopExplicitReverseLabel
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
Nadeau & Farrel Standards Track [Page 44]
^L
RFC 4802 GMPLS TE MIB February 2007
OBJECT gmplsTunnelHopExplicitReverseLabelPtr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- gmplsTunnelARHopTable
-- all objects have max access read-only
-- gmplsTunnelCHopTable
-- all objects have max access read-only
-- gmplsTunnelReversePerfTable
-- all objects have max access read-only
-- gmplsTunnelErrorTable
-- all objects have max access read-only
OBJECT gmplsTunnelErrorReporterType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
DESCRIPTION "Only unknown(0), ipv4(1), and ipv6(2) support
is required."
OBJECT gmplsTunnelErrorReporter
SYNTAX InetAddress (SIZE(0|4|16))
DESCRIPTION "An implementation is only required to support
unknown(0), ipv4(1), and ipv6(2)."
::= { gmplsTeCompliances 2 }
gmplsTunnelGroup OBJECT-GROUP
OBJECTS {
gmplsTunnelDirection,
gmplsTunnelReversePerfPackets,
gmplsTunnelReversePerfHCPackets,
gmplsTunnelReversePerfErrors,
gmplsTunnelReversePerfBytes,
gmplsTunnelReversePerfHCBytes,
gmplsTunnelErrorLastErrorType,
gmplsTunnelErrorLastTime,
gmplsTunnelErrorReporterType,
gmplsTunnelErrorReporter,
gmplsTunnelErrorCode,
gmplsTunnelErrorSubcode,
gmplsTunnelErrorTLVs,
gmplsTunnelErrorHelpString,
gmplsTunnelUnnumIf
}
STATUS current
DESCRIPTION
Nadeau & Farrel Standards Track [Page 45]
^L
RFC 4802 GMPLS TE MIB February 2007
"Necessary, but not sufficient, set of objects to implement
tunnels. In addition, depending on the type of the tunnels
supported (for example, manually configured or signaled,
persistent or non-persistent, etc.), the
gmplsTunnelSignaledGroup group is mandatory."
::= { gmplsTeGroups 1 }
gmplsTunnelSignaledGroup OBJECT-GROUP
OBJECTS {
gmplsTunnelAttributes,
gmplsTunnelLSPEncoding,
gmplsTunnelSwitchingType,
gmplsTunnelLinkProtection,
gmplsTunnelGPid,
gmplsTunnelSecondary,
gmplsTunnelPathComp,
gmplsTunnelUpstreamNotifyRecipientType,
gmplsTunnelUpstreamNotifyRecipient,
gmplsTunnelSendResvNotifyRecipientType,
gmplsTunnelSendResvNotifyRecipient,
gmplsTunnelDownstreamNotifyRecipientType,
gmplsTunnelDownstreamNotifyRecipient,
gmplsTunnelSendPathNotifyRecipientType,
gmplsTunnelSendPathNotifyRecipient,
gmplsTunnelAdminStatusFlags,
gmplsTunnelHopLabelStatuses,
gmplsTunnelHopExplicitForwardLabel,
gmplsTunnelHopExplicitForwardLabelPtr,
gmplsTunnelHopExplicitReverseLabel,
gmplsTunnelHopExplicitReverseLabelPtr
}
STATUS current
DESCRIPTION
"Objects needed to implement signaled tunnels."
::= { gmplsTeGroups 2 }
gmplsTunnelScalarGroup OBJECT-GROUP
OBJECTS {
gmplsTunnelsConfigured,
gmplsTunnelsActive
}
STATUS current
DESCRIPTION
"Scalar objects needed to implement MPLS tunnels."
::= { gmplsTeGroups 3 }
gmplsTunnelOptionalGroup OBJECT-GROUP
OBJECTS {
Nadeau & Farrel Standards Track [Page 46]
^L
RFC 4802 GMPLS TE MIB February 2007
gmplsTunnelExtraParamsPtr,
gmplsTunnelARHopLabelStatuses,
gmplsTunnelARHopExplicitForwardLabel,
gmplsTunnelARHopExplicitForwardLabelPtr,
gmplsTunnelARHopExplicitReverseLabel,
gmplsTunnelARHopExplicitReverseLabelPtr,
gmplsTunnelARHopProtection,
gmplsTunnelCHopLabelStatuses,
gmplsTunnelCHopExplicitForwardLabel,
gmplsTunnelCHopExplicitForwardLabelPtr,
gmplsTunnelCHopExplicitReverseLabel,
gmplsTunnelCHopExplicitReverseLabelPtr
}
STATUS current
DESCRIPTION
"The objects in this group are optional."
::= { gmplsTeGroups 4 }
gmplsTeNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
gmplsTunnelDown
}
STATUS current
DESCRIPTION
"Set of notifications implemented in this module. None is
mandatory."
::= { gmplsTeGroups 5 }
END
9. Security Considerations
It is clear that the MIB modules described in this document in
association with MPLS-TE-STD-MIB [RFC3812] are potentially useful for
monitoring of MPLS and GMPLS tunnels. These MIB modules can also be
used for configuration of certain objects, and anything that can be
configured can be incorrectly configured, with potentially disastrous
results.
There are a number of management objects defined in these MIB modules
with a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations. These are the tables and objects and their
sensitivity/vulnerability:
Nadeau & Farrel Standards Track [Page 47]
^L
RFC 4802 GMPLS TE MIB February 2007
o the gmplsTunnelTable and gmplsTunnelHopTable collectively contain
objects to provision GMPLS tunnels interfaces at their ingress
LSRs. Unauthorized write access to objects in these tables could
result in disruption of traffic on the network. This is
especially true if a tunnel has already been established.
Some of the readable objects in these MIB modules (i.e., objects with
a MAX-ACCESS other than not-accessible) may be considered sensitive
or vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. These are the tables and objects and their
sensitivity/vulnerability:
o the gmplsTunnelTable, gmplsTunnelHopTable, gmplsTunnelARHopTable,
gmplsTunnelCHopTable, gmplsTunnelReversePerfTable, and
gmplsTunnelErrorTable collectively show the tunnel network
topology and status. If an administrator does not want to reveal
this information, then these tables should be considered
sensitive/vulnerable.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in these MIB modules.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
including full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module, is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
10. Acknowledgments
This document is a product of the CCAMP Working Group.
This document extends [RFC3812]. The authors would like to express
their gratitude to all those who worked on that earlier MIB document.
Thanks also to Tony Zinicola and Jeremy Crossen for their valuable
contributions during an early implementation, and to Lars Eggert,
Nadeau & Farrel Standards Track [Page 48]
^L
RFC 4802 GMPLS TE MIB February 2007
Baktha Muralidharan, Tom Petch, Dan Romascanu, Dave Thaler, and Bert
Wijnen for their review comments.
Special thanks to Joan Cucchiara and Len Nieman for their help with
compilation issues.
Joan Cucchiara provided a helpful and very thorough MIB Doctor
review.
11. IANA Considerations
IANA has rooted MIB objects in the MIB modules contained in this
document according to the sections below.
11.1. IANA Considerations for GMPLS-TE-STD-MIB
IANA has rooted MIB objects in the GMPLS-TE-STD-MIB module contained
in this document under the mplsStdMIB subtree.
IANA has made the following assignments in the "NETWORK MANAGEMENT
PARAMETERS" registry located at http://www.iana.org/assignments/
smi-numbers in table:
...mib-2.transmission.mplsStdMIB (1.3.6.1.2.1.10.166)
Decimal Name References
------- ----- ----------
13 GMPLS-TE-STD-MIB [RFC4802]
In the future, GMPLS-related standards-track MIB modules should be
rooted under the mplsStdMIB (sic) subtree. IANA has been requested
to manage that namespace in the SMI Numbers registry [RFC3811]. New
assignments can only be made via a Standards Action as specified in
[RFC2434].
11.2. Dependence on IANA MIB Modules
Three MIB objects in the GMPLS-TE-STD-MIB module defined in this
document (gmplsTunnelLSPEncoding, gmplsTunnelSwitchingType, and
gmplsTunnelGPid) use textual conventions imported from the IANA-
GMPLS-TC-MIB module. The purpose of defining these textual
conventions in a separate MIB module is to allow additional values to
be defined without having to issue a new version of this document.
The Internet Assigned Numbers Authority (IANA) is responsible for the
assignment of all Internet numbers; it will administer the values
associated with these textual conventions.
Nadeau & Farrel Standards Track [Page 49]
^L
RFC 4802 GMPLS TE MIB February 2007
The rules for additions or changes to IANA-GMPLS-TC-MIB are outlined
in the DESCRIPTION clause associated with its MODULE-IDENTITY
statement.
The current version of IANA-GMPLS-TC-MIB can be accessed from the
IANA home page at: http://www.iana.org/.
11.2.1. IANA-GMPLS-TC-MIB Definition
This section provides the base definition of the IANA GMPLS TC MIB
module. This MIB module is under the direct control of IANA. Please
see the most updated version of this MIB at
<http://www.iana.org/assignments/ianagmplstc-mib>.
This MIB makes reference to the following documents: [RFC2578],
[RFC2579], [RFC3471], [RFC3473], [RFC4202], [RFC4328], and [RFC4783].
IANA assigned an OID to the IANA-GMPLS-TC-MIB module specified in
this document as { mib-2 152 }.
IANA-GMPLS-TC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, mib-2 FROM SNMPv2-SMI -- RFC 2578
TEXTUAL-CONVENTION FROM SNMPv2-TC; -- RFC 2579
ianaGmpls MODULE-IDENTITY
LAST-UPDATED
"200702270000Z" -- 27 February 2007 00:00:00 GMT
ORGANIZATION
"IANA"
CONTACT-INFO
"Internet Assigned Numbers Authority
Postal: 4676 Admiralty Way, Suite 330
Marina del Rey, CA 90292
Tel: +1 310 823 9358
E-Mail: iana@iana.org"
DESCRIPTION
"Copyright (C) The IETF Trust (2007). The initial version
of this MIB module was published in RFC 4802. For full legal
notices see the RFC itself. Supplementary information
may be available on:
http://www.ietf.org/copyrights/ianamib.html"
REVISION
"200702270000Z" -- 27 February 2007 00:00:00 GMT
DESCRIPTION
"Initial version issued as part of RFC 4802."
Nadeau & Farrel Standards Track [Page 50]
^L
RFC 4802 GMPLS TE MIB February 2007
::= { mib-2 152 }
IANAGmplsLSPEncodingTypeTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This type is used to represent and control
the LSP encoding type of an LSP signaled by a GMPLS
signaling protocol.
This textual convention is strongly tied to the LSP
Encoding Types sub-registry of the GMPLS Signaling
Parameters registry managed by IANA. Values should be
assigned by IANA in step with the LSP Encoding Types
sub-registry and using the same registry management rules.
However, the actual values used in this textual convention
are solely within the purview of IANA and do not
necessarily match the values in the LSP Encoding Types
sub-registry.
The definition of this textual convention with the
addition of newly assigned values is published
periodically by the IANA, in either the Assigned
Numbers RFC, or some derivative of it specific to
Internet Network Management number assignments. (The
latest arrangements can be obtained by contacting the
IANA.)
Requests for new values should be made to IANA via
email (iana@iana.org)."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS)
Signaling Functional Description, RFC 3471, section
3.1.1.
2. Generalized MPLS Signalling Extensions for G.709 Optical
Transport Networks Control, RFC 4328, section 3.1.1."
SYNTAX INTEGER {
tunnelLspNotGmpls(0), -- GMPLS is not in use
tunnelLspPacket(1), -- Packet
tunnelLspEthernet(2), -- Ethernet
tunnelLspAnsiEtsiPdh(3), -- PDH
-- the value 4 is deprecated
tunnelLspSdhSonet(5), -- SDH or SONET
-- the value 6 is deprecated
tunnelLspDigitalWrapper(7), -- Digital Wrapper
tunnelLspLambda(8), -- Lambda
tunnelLspFiber(9), -- Fiber
-- the value 10 is deprecated
tunnelLspFiberChannel(11), -- Fiber Channel
Nadeau & Farrel Standards Track [Page 51]
^L
RFC 4802 GMPLS TE MIB February 2007
tunnelDigitalPath(12), -- Digital Path
tunnelOpticalChannel(13) -- Optical Channel
}
IANAGmplsSwitchingTypeTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This type is used to represent and
control the LSP switching type of an LSP signaled by a
GMPLS signaling protocol.
This textual convention is strongly tied to the Switching
Types sub-registry of the GMPLS Signaling Parameters
registry managed by IANA. Values should be assigned by
IANA in step with the Switching Types sub-registry and
using the same registry management rules. However, the
actual values used in this textual convention are solely
within the purview of IANA and do not necessarily match
the values in the Switching Types sub-registry.
The definition of this textual convention with the
addition of newly assigned values is published
periodically by the IANA, in either the Assigned
Numbers RFC, or some derivative of it specific to
Internet Network Management number assignments. (The
latest arrangements can be obtained by contacting the
IANA.)
Requests for new values should be made to IANA via
email (iana@iana.org)."
REFERENCE
"1. Routing Extensions in Support of Generalized
Multi-Protocol Label Switching, RFC 4202, section 2.4.
2. Generalized Multi-Protocol Label Switching (GMPLS)
Signaling Functional Description, RFC 3471, section
3.1.1."
SYNTAX INTEGER {
unknown(0), -- none of the following, or not known
psc1(1), -- Packet-Switch-Capable 1
psc2(2), -- Packet-Switch-Capable 2
psc3(3), -- Packet-Switch-Capable 3
psc4(4), -- Packet-Switch-Capable 4
l2sc(51), -- Layer-2-Switch-Capable
tdm(100), -- Time-Division-Multiplex
lsc(150), -- Lambda-Switch-Capable
fsc(200) -- Fiber-Switch-Capable
}
Nadeau & Farrel Standards Track [Page 52]
^L
RFC 4802 GMPLS TE MIB February 2007
IANAGmplsGeneralizedPidTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used to represent and control the LSP
Generalized Protocol Identifier (G-PID) of an LSP
signaled by a GMPLS signaling protocol.
This textual convention is strongly tied to the Generalized
PIDs (G-PID) sub-registry of the GMPLS Signaling Parameters
registry managed by IANA. Values should be assigned by
IANA in step with the Generalized PIDs (G-PID) sub-registry
and using the same registry management rules. However, the
actual values used in this textual convention are solely
within the purview of IANA and do not necessarily match the
values in the Generalized PIDs (G-PID) sub-registry.
The definition of this textual convention with the
addition of newly assigned values is published
periodically by the IANA, in either the Assigned
Numbers RFC, or some derivative of it specific to
Internet Network Management number assignments. (The
latest arrangements can be obtained by contacting the
IANA.)
Requests for new values should be made to IANA via
email (iana@iana.org)."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS)
Signaling Functional Description, RFC 3471, section
3.1.1.
2. Generalized MPLS Signalling Extensions for G.709 Optical
Transport Networks Control, RFC 4328, section 3.1.3."
SYNTAX INTEGER {
unknown(0), -- unknown or none of the following
-- the values 1, 2, 3 and 4 are reserved in RFC 3471
asynchE4(5),
asynchDS3T3(6),
asynchE3(7),
bitsynchE3(8),
bytesynchE3(9),
asynchDS2T2(10),
bitsynchDS2T2(11),
reservedByRFC3471first(12),
asynchE1(13),
bytesynchE1(14),
bytesynch31ByDS0(15),
asynchDS1T1(16),
bitsynchDS1T1(17),
Nadeau & Farrel Standards Track [Page 53]
^L
RFC 4802 GMPLS TE MIB February 2007
bytesynchDS1T1(18),
vc1vc12(19),
reservedByRFC3471second(20),
reservedByRFC3471third(21),
ds1SFAsynch(22),
ds1ESFAsynch(23),
ds3M23Asynch(24),
ds3CBitParityAsynch(25),
vtLovc(26),
stsSpeHovc(27),
posNoScramble16BitCrc(28),
posNoScramble32BitCrc(29),
posScramble16BitCrc(30),
posScramble32BitCrc(31),
atm(32),
ethernet(33),
sdhSonet(34),
digitalwrapper(36),
lambda(37),
ansiEtsiPdh(38),
lapsSdh(40),
fddi(41),
dqdb(42),
fiberChannel3(43),
hdlc(44),
ethernetV2DixOnly(45),
ethernet802dot3Only(46),
g709ODUj(47),
g709OTUk(48),
g709CBRorCBRa(49),
g709CBRb(50),
g709BSOT(51),
g709BSNT(52),
gfpIPorPPP(53),
gfpEthernetMAC(54),
gfpEthernetPHY(55),
g709ESCON(56),
g709FICON(57),
g709FiberChannel(58)
}
IANAGmplsAdminStatusInformationTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type determines the setting of the
Admin Status flags in the Admin Status object or TLV, as
described in RFC 3471. Setting this object to a non-zero
value will result in the inclusion of the Admin Status
Nadeau & Farrel Standards Track [Page 54]
^L
RFC 4802 GMPLS TE MIB February 2007
object or TLV on signaling messages.
This textual convention is strongly tied to the
Administrative Status Information Flags sub-registry of
the GMPLS Signaling Parameters registry managed by IANA.
Values should be assigned by IANA in step with the
Administrative Status Flags sub-registry and using the
same registry management rules. However, the actual
values used in this textual convention are solely
within the purview of IANA and do not necessarily match
the values in the Administrative Status Information
Flags sub-registry.
The definition of this textual convention with the
addition of newly assigned values is published
periodically by the IANA, in either the Assigned
Numbers RFC, or some derivative of it specific to
Internet Network Management number assignments. (The
latest arrangements can be obtained by contacting the
IANA.)
Requests for new values should be made to IANA via
email (iana@iana.org)."
REFERENCE
"1. Generalized Multi-Protocol Label Switching (GMPLS)
Signaling Functional Description, RFC 3471, section 8.
2. Generalized MPLS Signaling - RSVP-TE Extensions,
RFC 3473, section 7.
3. GMPLS - Communication of Alarm Information,
RFC 4783, section 3.2.1."
SYNTAX BITS {
reflect(0), -- Reflect bit (RFC 3471)
reserved1(1), -- reserved
reserved2(2), -- reserved
reserved3(3), -- reserved
reserved4(4), -- reserved
reserved5(5), -- reserved
reserved6(6), -- reserved
reserved7(7), -- reserved
reserved8(8), -- reserved
reserved9(9), -- reserved
reserved10(10), -- reserved
reserved11(11), -- reserved
reserved12(12), -- reserved
reserved13(13), -- reserved
reserved14(14), -- reserved
reserved15(15), -- reserved
reserved16(16), -- reserved
Nadeau & Farrel Standards Track [Page 55]
^L
RFC 4802 GMPLS TE MIB February 2007
reserved17(17), -- reserved
reserved18(18), -- reserved
reserved19(19), -- reserved
reserved20(20), -- reserved
reserved21(21), -- reserved
reserved22(22), -- reserved
reserved23(23), -- reserved
reserved24(24), -- reserved
reserved25(25), -- reserved
reserved26(26), -- reserved
reserved27(27), -- Inhibit Alarm bit (RFC 4783)
reserved28(28), -- reserved
testing(29), -- Testing bit (RFC 3473)
administrativelyDown(30), -- Admin down (RFC 3473)
deleteInProgress(31) -- Delete bit (RFC 3473)
}
END
12. References
12.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2205] Braden, R., Zhang, L., Berson, S., Herzog, S., and S.
Jamin, "Resource ReSerVation Protocol (RSVP) -- Version 1
Functional Specification", RFC 2205, September 1997.
[RFC2434] Narten, T. and H. Alvestrand, "Guidelines for Writing an
IANA Considerations Section in RFCs", BCP 26, RFC 2434,
October 1998.
[RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Structure of Management Information Version 2 (SMIv2)",
STD 58, RFC 2578, April 1999.
[RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual
Conventions for SMIv2", STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580, April
1999.
[RFC3031] Rosen, E., Viswanathan, A., and R. Callon, "Multiprotocol
Label Switching Architecture", RFC 3031, January 2001.
Nadeau & Farrel Standards Track [Page 56]
^L
RFC 4802 GMPLS TE MIB February 2007
[RFC3209] Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V.,
and G. Swallow, "RSVP-TE: Extensions to RSVP for LSP
Tunnels", RFC 3209, December 2001.
[RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An
Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
December 2002.
[RFC3471] Berger, L., "Generalized Multi-Protocol Label Switching
(GMPLS) Signaling Functional Description", RFC 3471,
January 2003.
[RFC3473] Berger, L., "Generalized Multi-Protocol Label Switching
(GMPLS) Signaling Resource ReserVation Protocol-Traffic
Engineering (RSVP-TE) Extensions", RFC 3473, January 2003.
[RFC3477] Kompella, K. and Y. Rekhter, "Signalling Unnumbered Links
in Resource ReSerVation Protocol - Traffic Engineering
(RSVP-TE)", RFC 3477, January 2003.
[RFC3811] Nadeau, T. and J. Cucchiara, "Definitions of Textual
Conventions (TCs) for Multiprotocol Label Switching (MPLS)
Management", RFC 3811, June 2004.
[RFC3812] Srinivasan, C., Viswanathan, A., and T. Nadeau,
"Multiprotocol Label Switching (MPLS) Traffic Engineering
(TE) Management Information Base (MIB)", RFC 3812, June
2004.
[RFC3813] Srinivasan, C., Viswanathan, A., and T. Nadeau,
"Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB)", RFC 3813,
June 2004.
[RFC3945] Mannie, E., "Generalized Multi-Protocol Label Switching
(GMPLS) Architecture", RFC 3945, October 2004.
[RFC4001] Daniele, M., Haberman, B., Routhier, S., and J.
Schoenwaelder, "Textual Conventions for Internet Network
Addresses", RFC 4001, February 2005.
[RFC4202] Kompella, K. and Y. Rekhter, "Routing Extensions in Support
of Generalized Multi-Protocol Label Switching (GMPLS)", RFC
4202, October 2005.
Nadeau & Farrel Standards Track [Page 57]
^L
RFC 4802 GMPLS TE MIB February 2007
[RFC4328] Papadimitriou, D., "Generalized Multi-Protocol Label
Switching (GMPLS) Signaling Extensions for G.709 Optical
Transport Networks Control", RFC 4328, January 2006.
[RFC4783] Berger, L., "GMPLS - Communication of Alarm Information",
RFC 4783, December 2006.
[RFC4803] Nadeau, T., Ed. and A. Farrel, Ed., "Generalized
Multiprotocol Label Switching (GMPLS) Label Switching
Router (LSR) Management Information Base", RFC 4803,
February 2007.
12.2. Informative References
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
MIB", RFC 2863, June 2000.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
[RFC3472] Ashwood-Smith, P. and L. Berger, "Generalized Multi-
Protocol Label Switching (GMPLS) Signaling Constraint-based
Routed Label Distribution Protocol (CR-LDP) Extensions",
RFC 3472, January 2003.
Nadeau & Farrel Standards Track [Page 58]
^L
RFC 4802 GMPLS TE MIB February 2007
Contact Information
Thomas D. Nadeau
Cisco Systems, Inc.
1414 Massachusetts Ave.
Boxborough, MA 01719
EMail: tnadeau@cisco.com
Cheenu Srinivasan
Bloomberg L.P.
731 Lexington Ave.
New York, NY 10022
Phone: +1-212-617-3682
EMail: cheenu@bloomberg.net
Adrian Farrel
Old Dog Consulting
Phone: +44-(0)-1978-860944
EMail: adrian@olddog.co.uk
Tim Hall
Data Connection Ltd.
100 Church Street
Enfield, Middlesex
EN2 6BQ, UK
Phone: +44 20 8366 1177
EMail: tim.hall@dataconnection.com
Ed Harrison
Data Connection Ltd.
100 Church Street
Enfield, Middlesex
EN2 6BQ, UK
Phone: +44 20 8366 1177
EMail: ed.harrison@dataconnection.com
Nadeau & Farrel Standards Track [Page 59]
^L
RFC 4802 GMPLS TE MIB February 2007
Full Copyright Statement
Copyright (C) The IETF Trust (2007).
This document is subject to the rights, licenses and restrictions
contained in BCP 78, and except as set forth therein, the authors
retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND
THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF
THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at
ietf-ipr@ietf.org.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Nadeau & Farrel Standards Track [Page 60]
^L
|