1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
|
Internet Engineering Task Force (IETF) T. Dietz, Ed.
Request for Comments: 5815 NEC Europe, Ltd.
Category: Standards Track A. Kobayashi
ISSN: 2070-1721 NTT PF Labs.
B. Claise
Cisco Systems, Inc.
G. Muenz
Technische Universitaet Muenchen
April 2010
Definitions of Managed Objects for IP Flow Information Export
Abstract
This document defines managed objects for IP Flow Information eXport
(IPFIX). These objects provide information for monitoring IPFIX
Exporters and IPFIX Collectors including the basic configuration
information.
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Further information on
Internet Standards is available in Section 2 of RFC 5741.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc5815.
Copyright Notice
Copyright (c) 2010 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Dietz, et al. Standards Track [Page 1]
^L
RFC 5815 IPFIX MIB April 2010
Table of Contents
1. Introduction ....................................................3
2. IPFIX Documents Overview ........................................3
3. The Internet-Standard Management Framework ......................4
4. Terminology .....................................................4
5. Structure of the IPFIX MIB ......................................4
5.1. The Transport Session Table ................................4
5.2. The Template Table .........................................7
5.3. The Template Definition Table ..............................9
5.4. The Export Table ..........................................11
5.5. The Metering Process Table ................................12
5.6. The Observation Point Table ...............................13
5.7. The Selection Process Table ...............................14
5.8. The Statistical Tables ....................................15
5.8.1. The Transport Session Statistical Table ............15
5.8.2. The Template Statistical Table .....................15
5.8.3. The Metering Process Statistical Table .............15
5.8.4. The Selection Process Statistical Table ............15
6. Structure of the IPFIX SELECTOR MIB ............................15
6.1. The Selector Functions ....................................16
7. Relationship to Other MIB Modules ..............................18
7.1. Relationship to the ENTITY MIB and IF MIB .................18
7.2. MIB Modules Required for IMPORTS ..........................18
8. MIB Definitions ................................................18
8.1. IPFIX MIB Definition ......................................19
8.2. IPFIX SELECTOR MIB Definition .............................56
9. Security Considerations ........................................60
10. IANA Considerations ...........................................61
11. Acknowledgments ...............................................61
12. References ....................................................62
12.1. Normative References .....................................62
12.2. Informative References ...................................63
Dietz, et al. Standards Track [Page 2]
^L
RFC 5815 IPFIX MIB April 2010
1. Introduction
This document defines two MIB modules for monitoring IP Flow
Information eXport (IPFIX) Devices including Exporters and
Collectors. Most of the objects defined by the IPFIX MIB module MUST
be implemented. Some objects MAY be implemented corresponding to the
functionality implemented in the equipment. Since the IPFIX
architecture [RFC5470] foresees the possibility of using Filtering
and/or Sampling functions to reduce the data volume, this document
also provides the IPFIX SELECTOR MIB module, which contains the
standardized selection methods and is controlled by IANA. The full
configuration of the IPFIX Metering Process is out of the scope of
these MIB modules.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [RFC2119].
2. IPFIX Documents Overview
The IPFIX protocol provides network administrators with access to IP
Flow information. The architecture for the export of measured IP
Flow information out of an IPFIX Exporting Process to a Collecting
Process is defined in [RFC5470], per the requirements defined in
[RFC3917]. The protocol document [RFC5101] specifies how IPFIX Data
Records and Templates are carried via a congestion-aware transport
protocol from IPFIX Exporting Processes to IPFIX Collecting
Processes. IPFIX has a formal description of IPFIX Information
Elements, their name, type and additional semantic information, as
specified in [RFC5102]. Finally, [RFC5472] describes what type of
applications can use the IPFIX protocol and how they can use the
information provided. It furthermore shows how the IPFIX framework
relates to other architectures and frameworks.
It is assumed that Flow metering, export, and collection is performed
according to the IPFIX architecture defined in [RFC5470]. The
monitored configuration parameters of the export and collection of
Flow Templates and Data Records is modeled according to [RFC5101].
Packet selection methods that may be optionally used by the IPFIX
Metering Process are not considered in this MIB module. They are
defined in the Packet Sampling (PSAMP) framework [RFC5474] and
Sampling techniques [RFC5475] documents. Nevertheless, the basis for
defining Sampling and Filtering functions is given with the IPFIX
SELECTOR MIB module. Since the PSAMP export protocol [RFC5476] is
based on the IPFIX protocol, the Sampling and Filtering functions can
be added to the IPFIX SELECTOR MIB module as needed.
Dietz, et al. Standards Track [Page 3]
^L
RFC 5815 IPFIX MIB April 2010
3. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies MIB
modules that are compliant to the SMIv2, which is described in STD
58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC
2580 [RFC2580].
4. Terminology
The definitions of the basic terms like IP Traffic Flow, Exporting
Process, Collecting Process, Observation Points, etc. can be found in
the IPFIX protocol document [RFC5101].
5. Structure of the IPFIX MIB
The IPFIX MIB module consists of seven main tables, the Transport
Session table, the Template table and the corresponding Template
Definition table, the Export table, the Metering Process table, the
Observation Point table, and the Selection Process table. Since the
IPFIX architecture [RFC5470] foresees the possibility of using
Filtering and/or Sampling functions to reduce the data volume, the
MIB module provides the basic objects for these functions with the
Selection Process table. The IPFIX SELECTOR MIB module defined in
the next section provides the standard Filtering and Sampling
functions that can be referenced in the ipfixSelectionProcessTable.
All remaining objects contain statistical values for the different
tables contained in the MIB module.
The following subsections describe all tables in the IPFIX MIB
module.
5.1. The Transport Session Table
The Transport Session is the basis of the MIB module. The Transport
Session table (ipfixTransportSessionTable) contains all Transport
Sessions between Exporter and Collector. The table specifies the
transport layer protocol of the Transport Session and, depending on
that protocol, further parameters for the Transport Session. In the
case of UDP and TCP, these are the source and destination address as
Dietz, et al. Standards Track [Page 4]
^L
RFC 5815 IPFIX MIB April 2010
well as the source and destination port. For Stream Control
Transmission Protocol (SCTP), the table contains the SCTP Assoc Id,
which is the index for the SCTP association in the SCTP MIB module
[RFC3873]. The mode of operation of the device, i.e., if the
Transport Session is used for collecting or exporting is given in the
ipfixTransportSessionDeviceMode object. Further on, it contains the
configured refresh parameters for Templates and Options Templates
that are used across unreliable connections as UDP. Finally, the
IPFIX version that is exported or collected by this Transport Session
and a status of the Transport Session is given in the table.
To illustrate the use of the above tables, let us assume the
following scenario: we have an Exporter on IP address 192.0.2.22 and
a Collector on IP address 192.0.2.37. The Exporter uses TCP to
export Templates and Data Records. The same Exporter also exports,
with UDP, to a Collector with the IP address of 192.0.2.44. This
would lead to the following Transport Session table on the Exporter:
Dietz, et al. Standards Track [Page 5]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTransportSessionTable (1)
|
+- ipfixTransportSessionEntry (1)
|
+- index (5) (ipfixTransportSessionIndex)
| +- ipfixTransportSessionIndex (1) = 5
| +- ipfixTransportSessionProtocol (2) = 6 (TCP)
| +- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
| +- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
| +- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
| +- ipfixTransportSessionDestinationAddress (6) = 192.0.2.37
| +- ipfixTransportSessionSourcePort (7) = 7653
| +- ipfixTransportSessionDestinationPort (8) = 4739
| +- ipfixTransportSessionSctpAssocId (9) = 0
| +- ipfixTransportSessionDeviceMode (10) = exporting(1)
| +- ipfixTransportSessionTemplateRefreshTimeout (11) = 0
| +- ipfixTransportSessionOptionTemplateRefreshTimeout (12) = 0
| +- ipfixTransportSessionTemplateRefreshPacket (13) = 0
| +- ipfixTransportSessionOptionTemplateRefreshPacket (14) = 0
| +- ipfixTransportSessionIpfixVersion (15) = 10
| +- ipfixTransportSessionStatus (16) = 2 (active)
.
.
.
+- index (11) (ipfixTransportSessionIndex)
+- ipfixTransportSessionIndex (1) = 11
+- ipfixTransportSessionProtocol (2) = 17 (UDP)
+- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
+- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
+- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
+- ipfixTransportSessionDestinationAddress (6) = 192.0.2.44
+- ipfixTransportSessionSourcePort (7) = 14287
+- ipfixTransportSessionDestinationPort (8) = 4739
+- ipfixTransportSessionSctpAssocId (9) = 0
+- ipfixTransportSessionDeviceMode (10) = exporting(1)
+- ipfixTransportSessionTemplateRefreshTimeout (11) = 100
+- ipfixTransportSessionOptionTemplateRefreshTimeout (12)
| = 100
+- ipfixTransportSessionTemplateRefreshPacket (13) = 10
+- ipfixTransportSessionOptionTemplateRefreshPacket (14) = 10
+- ipfixTransportSessionIpfixVersion (15) = 10
+- ipfixTransportSessionStatus (16) = 2 (active)
The values in brackets are the OID numbers. The Collectors would
then have the same entry except that the index would most likely
differ and the ipfixTransportSessionDeviceMode would be
collecting(2).
Dietz, et al. Standards Track [Page 6]
^L
RFC 5815 IPFIX MIB April 2010
5.2. The Template Table
The Template table lists all Templates (including Options Templates)
that are sent (by an Exporter) or received (by a Collector). The
(Options) Templates are unique per Transport Session, which also
gives the device mode (Exporter or Collector) and Observation Domain;
thus, the table is indexed by:
o the Transport Session Index (ipfixTransportSessionIndex)
o and the Observation Domain Id (ipfixTemplateObservationDomainId).
It contains the Set Id and an access time denoting the time when the
(Options) Template was last sent or received.
To resume the above example, the Exporter may want to export a
Template and an Options Template for each Transport Session defined
above. This leads to the following Template table defining Template
and Options Template:
Dietz, et al. Standards Track [Page 7]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateTable (3)
|
+- ipfixTemplateEntry (1)
|
+- index (5) (ipfixTransportSessionIndex)
| +- index (3) (ipfixTemplateObservationDomainId)
| + index (257) (ipfixTemplateId)
| | +- ipfixTemplateObservationDomainId (1) = 3
| | +- ipfixTemplateId (2) = 257
| | +- ipfixTemplateSetId (3) = 2
| | +- ipfixTemplateAccessTime (4)
| | = 2008-7-1,12:49:11.2,+2:0
| |
| + index (264) (ipfixTemplateId)
| +- ipfixTemplateObservationDomainId (1) = 3
| +- ipfixTemplateId (2) = 264
| +- ipfixTemplateSetId (3) = 3
| +- ipfixTemplateAccessTime (4)
. = 2008-7-1,12:47:04.8,+2:0
.
.
.
+- index (11) (ipfixTransportSessionIndex)
+- index (3) (ipfixTemplateObservationDomainId)
+ index (273) (ipfixTemplateId)
| +- ipfixTemplateObservationDomainId (1) = 3
| +- ipfixTemplateId (2) = 273
| +- ipfixTemplateSetId (3) = 2
| +- ipfixTemplateAccessTime (4)
| = 2008-7-1,12:49:11.2,+2:0
|
+ index (289) (ipfixTemplateId)
+- ipfixTemplateObservationDomainId (1) = 3
+- ipfixTemplateId (2) = 289
+- ipfixTemplateSetId (3) = 3
+- ipfixTemplateAccessTime (4)
= 2008-7-1,12:47:04.8,+2:0
We assume that the Transport Session that is stored with index 5 in
the Transport Session table of the Exporter is stored with index 17
in the Transport Session table of the (corresponding) Collector.
Then, the Template table would look as follows:
Dietz, et al. Standards Track [Page 8]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateTable (3)
|
+- ipfixTemplateEntry (1)
|
+- index (17) (ipfixTransportSessionIndex)
+- index (3) (ipfixTemplateObservationDomainId)
+ index (257) (ipfixTemplateId)
| +- ipfixTemplateObservationDomainId (1) = 3
| +- ipfixTemplateId (2) = 257
| +- ipfixTemplateSetId (3) = 2
| +- ipfixTemplateAccessTime (4)
| = 2008-7-1,12:49:11.8,+2:0
|
+ index (264) (ipfixTemplateId)
+- ipfixTemplateObservationDomainId (1) = 3
+- ipfixTemplateId (2) = 264
+- ipfixTemplateSetId (3) = 3
+- ipfixTemplateAccessTime (4)
= 2008-7-1,12:47:05.3,+2:0
The table on the second Collector would be analogous to the one shown
above.
5.3. The Template Definition Table
The Template Definition table lists all the Information Elements
contained in a Template or Options Template. Therefore, it has the
same indexes as the corresponding Template table plus the Template
Id. Its own index denotes the order of the Information Element
inside the Template. Besides the Information Element Id and the
length of the encoded value, the table contains the enterprise number
for enterprise-specific Information Elements and flags for each
Information Element. The flags indicate if the Information Element
is used for scoping or as a Flow Key.
To resume the above example again, the Exporter is configured to
export the octets received and dropped at the Observation Point since
the last export of these values. In addition, it exports the start
and end time of the Flow relative to the timestamp contained in the
IPFIX header. This leads to the following Template Definition table
on the Exporter:
Dietz, et al. Standards Track [Page 9]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateDefinitionTable (4)
|
+- ipfixTemplateDefinitionEntry (1)
|
+- index (5) (ipfixTransportSessionIndex)
+- index (3) (ipfixTemplateObservationDomainId)
+ index (257) (ipfixTemplateId)
+- index (1) (ipfixTemplateDefinitionIndex)
| +- ipfixTemplateDefinitionIndex (1) = 1
| +- ipfixTemplateDefinitionIeId (2) = 158
| | (flowStartDeltaMicroseconds)
| +- ipfixTemplateDefinitionIeLength (3) = 4
| +- ipfixTemplateDefinitionEnterprise (4) = 0
| +- ipfixTemplateDefinitionFlags (5) = 0
|
+- index (2) (ipfixTemplateDefinitionIndex)
| +- ipfixTemplateDefinitionIndex (1) = 2
| +- ipfixTemplateDefinitionIeId (2) = 159
| | (flowEndDeltaMicroseconds)
| +- ipfixTemplateDefinitionIeLength (3) = 4
| +- ipfixTemplateDefinitionEnterprise (4) = 0
| +- ipfixTemplateDefinitionFlags (5) = 0
|
+- index (3) (ipfixTemplateDefinitionIndex)
| +- ipfixTemplateDefinitionIndex (1) = 3
| +- ipfixTemplateDefinitionIeId (2) = 1
| | (octetDeltaCount)
| +- ipfixTemplateDefinitionIeLength (3) = 8
| +- ipfixTemplateDefinitionEnterprise (4) = 0
| +- ipfixTemplateDefinitionFlags (5) = 0
|
+- index (4) (ipfixTemplateDefinitionIndex)
+- ipfixTemplateDefinitionIndex (1) = 4
+- ipfixTemplateDefinitionIeId (2) = 132
| (droppedOctetDeltaCount)
+- ipfixTemplateDefinitionIeLength (3) = 8
+- ipfixTemplateDefinitionEnterprise (4) = 0
+- ipfixTemplateDefinitionFlags (5) = 0
The corresponding table entry on the Collector is the same except
that it would have another ipfixTransportSessionIndex, e.g., 17 as in
the previous example.
Dietz, et al. Standards Track [Page 10]
^L
RFC 5815 IPFIX MIB April 2010
5.4. The Export Table
On Exporters, the Export table (ipfixExportTable) can be used to
support features like failover, load-balancing, duplicate export to
several Collectors, etc. The table has three indexes that link an
entry with:
o the Metering Process table (ipfixMeteringProcessCacheId, see
below)
o and the Transport Session table (ipfixTransportSessionIndex).
Those entries with the same ipfixExportIndex and the same
ipfixMeteringProcessCacheId define a Transport Session group. The
member type for each group member describes its functionality. All
Transport Sessions referenced in this table MUST have the
ipfixTransportSessionDeviceMode exporting(1).
If the Exporter does not use Transport Session grouping, then each
ipfixExportIndex contains a single ipfixMeteringProcessCacheId, and
thus a singe Transport Session (ipfixTransportSessionIndex) and this
session MUST have the member type primary(1).
For failover, a Transport Session group can contain one Transport
Session with member type "primary" and several Transport Sessions
with type secondary(2). Entries with other member types are not
allowed for that type of group. For load-balancing or parallel
export, all Transport Sessions in the group MUST have the same member
type, either loadBalancing(4) or parallel(3).
The algorithms used for failover or load-balancing are out of the
scope of this document.
To continue the example, we assume that the Exporter uses the two
connections shown in the examples above as one primary Transport
Session protected by a secondary Transport Session. The Exporter
then has the following entries in the ipfixExportTable:
Dietz, et al. Standards Track [Page 11]
^L
RFC 5815 IPFIX MIB April 2010
ipfixExportTable (5)
|
+- ipfixExportEntry (1)
|
+- index (7) (ipfixExportIndex)
| +- index (9) (ipfixMeteringProcessCacheId)
| | +- index (5) (ipfixTransportSessionIndex)
| | +- ipfixExportIndex (1) = 7
| | +- ipfixExportMemberType (2) = 1 (primary)
| |
| +- index (11) (ipfixTransportSessionIndex)
| +- ipfixExportIndex (1) = 7
| +- ipfixExportMemberType (2) = 2 (secondary)
|
+- index (8) (ipfixExportIndex)
+- index (9) (ipfixMeteringProcessCacheId)
+- index (5) (ipfixTransportSessionIndex)
| +- ipfixExportIndex (1) = 8
| +- ipfixExportMemberType (2) = 2 (secondary)
+- index (11) (ipfixTransportSessionIndex)
+- ipfixExportIndex (1) = 8
+- ipfixExportMemberType (2) = 1 (primary)
The example shows that the Exporter uses the Metering Process Cache
9, explained below, to export IPFIX Data Records for the Transport
Sessions 5 and 11. The Templates 257 and 264 defined above are
exported within Transport Session 5, and the Templates 273 and 289
are exported within Transport Session 11. If we assume that
Templates 257 and 264 are identical, then the Collector that receives
Transport Session 11 is a backup for the Collector of Transport
Session 5.
5.5. The Metering Process Table
The Metering Process, as defined in [RFC5101], consists of a set of
functions. Maintaining the Flow Records is one of them. This
function is responsible for passing the Flow Records to the Exporting
Process and also for detecting Flow expiration. The Flow Records
that are maintained by the Metering Process can be grouped by the
Observation Points at which they are observed. The instance that
maintains such a group of Flow Records is a kind of cache. For this
reason, the Metering Process table (ipfixMeteringProcessTable) is
indexed by cache Ids (ipfixMeteringProcessCacheId). Each cache can
be maintained by a separate instance of the Metering Process. To
specify the Observation Point(s) where the Flow Records are gathered,
the ipfixMeteringProcessObservationPointGroupRef may contain an
ipfixObservationPointGroupId from the Observation Point table
(ipfixObservationPointTable) described in the next section. If an
Dietz, et al. Standards Track [Page 12]
^L
RFC 5815 IPFIX MIB April 2010
Observation Point is not specified for the Flow Records, the
ipfixMeteringProcessObservationPointGroupRef MUST be zero(0). The
timeouts (ipfixMeteringProcessCacheActiveTimeout and
ipfixMeteringProcessCacheInactiveTimeout) specify when Flows are
expired.
ipfixMeteringProcessTable (6)
|
+- ipfixMeteringProcessEntry (1)
|
+- index (9) (ipfixMeteringProcessCacheId)
+- ipfixMeteringProcessCacheId (1) = 9
+- ipfixMeteringProcessObservationPointGroupRef (2) = 17
+- ipfixMeteringProcessCacheActiveTimeout (3) = 100
+- ipfixMeteringProcessCacheInactiveTimeout (4) = 100
5.6. The Observation Point Table
The Observation Point table (ipfixObservationPointTable) groups
Observation Points with the ipfixObservationPointGroupId. Each entry
contains the Observation Domain Id in which the Observation Point is
located and a reference to the ENTITY MIB module [RFC4133] or the IF
MIB module [RFC2863]. The objects in the ENTITY MIB module
referenced by ipfixObservationPointPhysicalEntity or IF MIB module
referenced by ipfixObservationPointPhysicalInterface denote the
Observation Point. If no such index can be given in those modules,
the references MUST be 0. If a reference is given in both object
ipfixObservationPointPhysicalEntity and
ipfixObservationPointPhysicalInterface, then both MUST point to the
same physical interface. In addition, a direction can be given to
render more specifically which Flow to monitor.
Dietz, et al. Standards Track [Page 13]
^L
RFC 5815 IPFIX MIB April 2010
ipfixObservationPointTable (7)
|
+- ipfixObservationPointEntry (1)
|
+- index (17) (ipfixObservationPointGroupId)
+- index (1) (ipfixObservationPointIndex)
| +- ipfixObservationPointGroupId (1) = 17
| +- ipfixObservationPointIndex (2) = 1
| +- ipfixObservationPointObservationDomainId (3) = 3
| +- ipfixObservationPointPhysicalEntity (4) = 6
| +- ipfixObservationPointPhysicalInterface(5) = 0
| +- ipfixObservationPointPhysicalEntityDirection (6)
= 3 (both)
|
+- index (2) (ipfixObservationPointIndex)
+- ipfixObservationPointGroupId (1) = 17
+- ipfixObservationPointIndex (2) = 2
+- ipfixObservationPointObservationDomainId (3) = 3
+- ipfixObservationPointPhysicalEntity (4) = 0
+- ipfixObservationPointPhysicalInterface (5) = 0
+- ipfixObservationPointPhysicalEntityDirection (6)
= 1 (ingress)
5.7. The Selection Process Table
This table supports the usage of Filtering and Sampling functions, as
described in [RFC5470]. It contains lists of functions per Metering
Process cache (ipfixMeteringProcessCacheId). The selection process
index ipfixSelectionProcessIndex forms groups of selection methods
that are applied to an observed packet stream. The selection process
selector index (ipfixSelectionProcessSelectorIndex) indicates the
order in which the functions are applied to the packets observed at
the Observation Points associated with the Metering Process cache.
The selection methods are applied in increasing order, i.e.,
selection methods with a lower ipfixSelectionProcessSelectorIndex are
applied first. The functions are referred by object identifiers
pointing to the function with its parameters. If the selection
method does not use parameters, then it MUST point to the root of the
function subtree (see also Section 6). If the function uses
parameters, then it MUST point to an entry in the parameter table of
the selection method. If no Filtering or Sampling function is used
for a Metering Process, then an entry for the Metering Process SHOULD
be created pointing to the Select All function (ipfixFuncSelectAll).
Dietz, et al. Standards Track [Page 14]
^L
RFC 5815 IPFIX MIB April 2010
5.8. The Statistical Tables
For the ipfixTransportSessionTable, the ipfixTemplateTable, the
ipfixMeteringProcessTable, and the ipfixSelectionProcessTable
statistical tables are defined that augment those tables. All the
statistical tables contain a discontinuity object that holds a
timestamp that denotes the time when a discontinuity event occurred
to notify the management system that the counters contained in those
tables might not be continuous anymore.
5.8.1. The Transport Session Statistical Table
The Transport Session Statistical table
(ipfixTransportSessionStatsTable) augments the
ipfixTransportSessionTable with statistical values. It contains the
rate (in bytes per second) with which it receives or sends out IPFIX
Messages, the number of bytes, packets, messages, Records, Templates
and Options Templates received or sent and the number of messages
that were discarded.
5.8.2. The Template Statistical Table
This table contains a statistical value for each Template. It
augments the Template table (ipfixTemplateTable) and specifies the
number of Data Records exported or collected for the Template.
5.8.3. The Metering Process Statistical Table
This table augments the Metering Process table
(ipfixMeteringProcessTable). It contains the statistical values for
the exported Data Records and the number of unused cache entries.
5.8.4. The Selection Process Statistical Table
This table augments the Selection Process table
(ipfixSelectionProcessTable) and introduces two generic statistical
values, the number of packets observed and the number of packets
dropped by the selection method.
6. Structure of the IPFIX SELECTOR MIB
The IPFIX SELECTOR MIB module defined in this section provides the
standard Filtering and Sampling functions that can be referenced in
the ipfixSelectionProcessTable. The subtree ipfixSelectorFunctions
is a placeholder where all standard Filtering and Sampling functions
should be located. It currently contains the Select All function
(ipfixFuncSelectAll). The IPFIX SELECTOR MIB module is maintained by
IANA and can be extended through Expert Review [RFC5226], i.e.,
Dietz, et al. Standards Track [Page 15]
^L
RFC 5815 IPFIX MIB April 2010
review by one of a group of experts designated by an IETF Area
Director. The group of experts MUST check the requested MIB objects
for completeness and accuracy of the description. Requests for MIB
objects that duplicate the functionality of existing objects SHOULD
be declined. The smallest available OID SHOULD be assigned to a new
MIB objects. The specification of new MIB objects SHOULD follow the
structure specified in the next Section and MUST be published using a
well-established and persistent publication medium. The experts will
initially be drawn from the Working Group Chairs and document editors
of the IPFIX and PSAMP Working Groups.
6.1. The Selector Functions
The following figure shows what the MIB tree usually should look
like. It already contains the ipfixFuncSelectAll. The subtree in
ipfixFuncF2 gives the basic structure that all selection methods
SHOULD follow.
ipfixSelectorFunctions
|
+- ipfixFuncSelectAll
| |
| +- ipfixFuncSelectAllAvail (is the function available?)
|
+- ipfixFuncF2
| |
| +- ipfixFuncF2Avail (is the function F2 available?)
| |
| +- ipfixFuncF2Parameters (a table with parameters)
...
|
+- ipfixFunFn...
The selection method SHOULD be designed as a MIB subtree introduced
by an object with the name ipfixFunc appended by a function name.
The objects in this subtree SHOULD be prefixed by this name. If the
function is named Fx, then we would start a subtree with an OID named
ipfixFuncFx. This subtree should contain an object ipfixFuncFxAvail
that has the type TruthValue. If a selection method takes
parameters, the MIB should contain a table named
ipfixFuncFxParameters, which should contain all the parameters that
the selection method specifies. An entry in this table will be
referenced by the IPFIX MIB module if the selection method with the
parameters is used.
Dietz, et al. Standards Track [Page 16]
^L
RFC 5815 IPFIX MIB April 2010
To illustrate the structure defined above, the following contains an
example of a function MyFunc that holds three integer parameters
Param1, Param2, and Param3. In the example, there are currently two
instances of the parameters set defined with indexes 1 and 4.
ipfixSelectorFunctions (1)
|
+- ipfixFuncMyFunc (?)
|
+- ipfixFuncMyFuncAvail (1) = true
+- ipfixFuncMyFuncParameters (2)
|
+- ipfixFuncMyFuncParametersEntry (1)
|
+- index (1) (ipfixFuncMyFuncParametersIndex)
| +- ipfixFuncMyFuncParam1 (1) = 47
| +- ipfixFuncMyFuncParam2 (2) = -128
| +- ipficFuncMyFuncParam3 (3) = 19
|
+- index(4) (ipfixFuncMyFuncParametersIndex)
+- ipfixFuncMyFuncParam1 (1) = 19
+- ipfixFuncMyFuncParam2 (2) = -1
+- ipficFuncMyFuncParam3 (3) = 728
If the function defined above is referenced in the IPFIX MIB module,
the ipfixSelectionProcessTable would look as follows:
ipfixSelectionProcessTable (8)
|
+- ipfixSelectionProcessEntry (1)
|
+- index (9) (ipfixMeteringProcessCacheId)
+- index (1) (ipfixSelectionProcessIndex)
+- index (1) (ipfixSelectionProcessSelectorIndex)
| +- ipfixSelectionProcessSelectorFunction (3)
| = ipfixSelectorFunctions.?.2.1.4
+- index (2) (ipfixSelectionProcessSelectorIndex)
+- ipfixSelectionProcessSelectorFunction (3)
= ipfixSelectorFunctions.?.2.1.1
This means that for the ipfixMeteringProcessCacheId(9), a Selection
Process with index 1 is created that applies two times the same
function but with different parameter sets. First, the function
MyFunc is applied with the parameters of the set with index 4 and the
with the parameters of the set with index 1.
Dietz, et al. Standards Track [Page 17]
^L
RFC 5815 IPFIX MIB April 2010
7. Relationship to Other MIB Modules
Besides the usual imports from the SNMP Standards [RFC2578],
[RFC2579], and [RFC2580], the IPFIX MIB module references the ENTITY
MIB module [RFC4133] and the IF MIB module [RFC2863].
7.1. Relationship to the ENTITY MIB and IF MIB
The Observation Point table (ipfixObservationPointTable) contains a
reference to the ENTITY MIB module[RFC4133]
(ipfixObservationPointPhysicalEntity) or the IF MIB module [RFC2863]
(ipfixObservationPointPhysicalInterface). If the implementors of the
IPFIX MIB module want to specify the physical entity where Flows are
observed, then they SHOULD also implement the ENTITY MIB and/or the
IF MIB module. The implementation of the ENTITY MIB and/or IF MIB
module is OPTIONAL. If one of them is not implemented, then all
values of the respective column ipfixObservationPointPhysicalEntity
or ipfixObservationPointPhysicalInterface in the Observation Point
table are zero and the values of the
ipfixObservationPointPhysicalEntityDirection columns are unknown(0),
if none of them are defined.
7.2. MIB Modules Required for IMPORTS
The IPFIX MIB module requires the modules SNMPv2-SMI [RFC2578],
SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580]. Further on, it
imports the textual conventions InetAddressType and InetAddress from
the INET ADDRESS MIB module [RFC4001].
The IPFIX SELECTOR MIB module also requires the modules SNMPv2-SMI
[RFC2578], SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580].
8. MIB Definitions
This section contains the definitions of the IPFIX-MIB module and the
IPFIX-SELECTOR-MIB module. There are different mandatory groups
defined for Collector and Exporter implementations. The statistical
objects are made OPTIONAL.
Dietz, et al. Standards Track [Page 18]
^L
RFC 5815 IPFIX MIB April 2010
8.1. IPFIX MIB Definition
IPFIX-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, mib-2, Unsigned32, Counter64,
Gauge32
FROM SNMPv2-SMI -- RFC2578
TimeStamp, DateAndTime
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC2580
InterfaceIndexOrZero
FROM IF-MIB -- RFC2863
InetAddressType, InetAddress, InetPortNumber
FROM INET-ADDRESS-MIB -- RFC4001
PhysicalIndexOrZero
FROM ENTITY-MIB; -- RFC4133
ipfixMIB MODULE-IDENTITY
LAST-UPDATED "201004190000Z" -- 19 April 2010
ORGANIZATION "IETF IPFIX Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/ipfix-charter.html
Mailing Lists:
General Discussion: ipfix@ietf.org
To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
Archive:
http://www1.ietf.org/mail-archive/web/ipfix/current/index.html
Editor:
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-128
Email: Thomas.Dietz@nw.neclab.eu
Dietz, et al. Standards Track [Page 19]
^L
RFC 5815 IPFIX MIB April 2010
Atsushi Kobayashi
NTT Information Sharing Platform Laboratories
3-9-11 Midori-cho
Musashino-shi
180-8585
Japan
Phone: +81-422-59-3978
Email: akoba@nttv6.net
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Degem 1831
Belgium
Phone: +32 2 704 5622
Email: bclaise@cisco.com
Gerhard Muenz
Technische Universitaet Muenchen
Department of Informatics
Chair for Network Architectures and Services (I8)
Boltzmannstr. 3
85748 Garching
Germany
Phone: +49 89 289-18008
Email: muenz@net.in.tum.de
URI: http://www.net.in.tum.de/~muenz"
DESCRIPTION
"The IPFIX MIB defines managed objects for IP Flow
Information eXport. These objects provide information about
managed nodes supporting the IPFIX protocol,
for Exporters as well as for Collectors.
Copyright (c) 2010 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD
License set forth in Section 4.c of the IETF Trust's
Legal Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
Dietz, et al. Standards Track [Page 20]
^L
RFC 5815 IPFIX MIB April 2010
-- Revision history
REVISION "201004190000Z" -- 19 April 2010
DESCRIPTION
"Initial version, published as RFC 5815."
::= { mib-2 193 }
--******************************************************************
-- Top Level Structure of the MIB
--******************************************************************
ipfixObjects OBJECT IDENTIFIER ::= { ipfixMIB 1 }
ipfixConformance OBJECT IDENTIFIER ::= { ipfixMIB 2 }
ipfixMainObjects OBJECT IDENTIFIER ::= { ipfixObjects 1 }
ipfixStatistics OBJECT IDENTIFIER ::= { ipfixObjects 2 }
--==================================================================
-- 1.1: Objects used by all IPFIX implementations
--==================================================================
--------------------------------------------------------------------
-- 1.1.1: Transport Session Table
--------------------------------------------------------------------
ipfixTransportSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixTransportSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the currently established Transport
Sessions between an Exporting Process and a Collecting
Process."
::= { ipfixMainObjects 1 }
ipfixTransportSessionEntry OBJECT-TYPE
SYNTAX IpfixTransportSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixTransportSessionTable."
INDEX { ipfixTransportSessionIndex }
::= { ipfixTransportSessionTable 1 }
Dietz, et al. Standards Track [Page 21]
^L
RFC 5815 IPFIX MIB April 2010
IpfixTransportSessionEntry ::=
SEQUENCE {
ipfixTransportSessionIndex Unsigned32,
ipfixTransportSessionProtocol Unsigned32,
ipfixTransportSessionSourceAddressType InetAddressType,
ipfixTransportSessionSourceAddress InetAddress,
ipfixTransportSessionDestinationAddressType InetAddressType,
ipfixTransportSessionDestinationAddress InetAddress,
ipfixTransportSessionSourcePort InetPortNumber,
ipfixTransportSessionDestinationPort InetPortNumber,
ipfixTransportSessionSctpAssocId Unsigned32,
ipfixTransportSessionDeviceMode INTEGER,
ipfixTransportSessionTemplateRefreshTimeout Unsigned32,
ipfixTransportSessionOptionsTemplateRefreshTimeout Unsigned32,
ipfixTransportSessionTemplateRefreshPacket Unsigned32,
ipfixTransportSessionOptionsTemplateRefreshPacket Unsigned32,
ipfixTransportSessionIpfixVersion Unsigned32,
ipfixTransportSessionStatus INTEGER
}
ipfixTransportSessionIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in
the ipfixTransportSessionTable. The value is expected to
remain constant from a re-initialization of the entity's
network management agent to the next re-initialization."
::= { ipfixTransportSessionEntry 1 }
ipfixTransportSessionProtocol OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol used for receiving or transmitting
IPFIX Messages. Protocol numbers are assigned by IANA. A
current list of all assignments is available from
<http://www.iana.org/>."
REFERENCE
"RFC 5101, Specification of the IP Flow
Information Export (IPFIX) Protocol for the Exchange of IP
Traffic Flow Information, Section 10."
::= { ipfixTransportSessionEntry 2 }
Dietz, et al. Standards Track [Page 22]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTransportSessionSourceAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of address used for the source address,
as specified in RFC 4001. This object is used with protocols
(specified in ipfixTransportSessionProtocol) like TCP (6)
and UDP (17) that have the notion of addresses. SCTP (132)
should use the ipfixTransportSessionSctpAssocId instead.
If SCTP (132) or any other protocol without the notion of
addresses is used, the object MUST be set to unknown(0)."
::= { ipfixTransportSessionEntry 3 }
ipfixTransportSessionSourceAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source address of the Exporter of the IPFIX Transport
Session. This value is interpreted according to the value of
ipfixTransportSessionAddressType as specified in RFC 4001.
This object is used with protocols (specified in
ipfixTransportSessionProtocol) like TCP (6) and UDP (17) that
have the notion of addresses. SCTP (132) should use the
ipfixTransportSessionSctpAssocId instead. If SCTP (132) or
any other protocol without the notion of addresses is used,
the object MUST be set to a zero-length string."
::= { ipfixTransportSessionEntry 4 }
ipfixTransportSessionDestinationAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of address used for the destination address,
as specified in RFC 4001. This object is used with protocols
(specified in ipfixTransportSessionProtocol) like TCP (6)
and UDP (17) that have the notion of addresses. SCTP (132)
should use the ipfixTransportSessionSctpAssocId instead.
If SCTP (132) or any other protocol without the notion of
addresses is used, the object MUST be set to unknown(0)."
::= { ipfixTransportSessionEntry 5 }
ipfixTransportSessionDestinationAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 23]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The destination address of the Collector of the IPFIX
Transport Session. This value is interpreted according to
the value of ipfixTransportSessionAddressType, as specified
in RFC 4001. This object is used with protocols
(specified in ipfixTransportSessionProtocol) like TCP (6)
and UDP (17) that have the notion of addresses. SCTP (132)
should use the ipfixTransportSessionSctpAssocId instead.
If SCTP (132) or any other protocol without the notion of
addresses is used, the object MUST be set to a zero-length
string"
::= { ipfixTransportSessionEntry 6 }
ipfixTransportSessionSourcePort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol port number of the Exporter.
This object is used with protocols (specified in
ipfixTransportSessionProtocol) like TCP (6)
and UDP (17) that have the notion of ports. SCTP (132)
should copy the value of sctpAssocLocalPort if the
Transport Session is in collecting mode or
sctpAssocRemPort if the Transport Session is in
exporting mode. The association is referenced
by the ipfixTransportSessionSctpAssocId.
If any other protocol without the notion of
ports is used, the object MUST be set to zero."
::= { ipfixTransportSessionEntry 7 }
ipfixTransportSessionDestinationPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol port number of the Collector. The
default value is 4739 for all currently defined transport
protocol types. This object is used with protocols
(specified in ipfixTransportSessionProtocol) like TCP (6)
and UDP (17) that have the notion of ports. SCTP (132)
should copy the value of sctpAssocRemPort if the
Transport Session is in collecting mode or
sctpAssocLocalPort if the Transport Session is in
exporting mode. The association is referenced
by the ipfixTransportSessionSctpAssocId.
If any other protocol without the notion of
ports is used, the object MUST be set to zero."
Dietz, et al. Standards Track [Page 24]
^L
RFC 5815 IPFIX MIB April 2010
::= { ipfixTransportSessionEntry 8 }
ipfixTransportSessionSctpAssocId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The association id used for the SCTP session between the
Exporter and the Collector of the IPFIX Transport Session.
It is equal to the sctpAssocId entry in the sctpAssocTable
defined in the SCTP MIB. This object is only valid if
ipfixTransportSessionProtocol has the value 132 (SCTP). In
all other cases, the value MUST be zero."
REFERENCE
"RFC 3873, Stream Control Transmission Protocol (SCTP)
Management Information Base (MIB)."
::= { ipfixTransportSessionEntry 9 }
ipfixTransportSessionDeviceMode OBJECT-TYPE
SYNTAX INTEGER {
exporting(1),
collecting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode of operation of the device for the given Transport
Session. This object can have the following values:
exporting(1)
This value MUST be used if the Transport Session is
used for exporting Records to other IPFIX Devices,
i.e., this device acts as Exporter.
collecting(2)
This value MUST be used if the Transport Session is
used for collecting Records from other IPFIX Devices,
i.e., this device acts as Collector."
::= { ipfixTransportSessionEntry 10 }
ipfixTransportSessionTemplateRefreshTimeout OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 25]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"On Exporters, this object contains the time in seconds
after which IPFIX Templates are resent by the
Exporter.
On Collectors, this object contains the lifetime in seconds
after which a Template becomes invalid when it is not
received again within this lifetime.
This object is only valid if ipfixTransportSessionProtocol
has the value 17 (UDP). In all other cases, the value MUST
be zero."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 10.3.6 and 10.3.7."
::= { ipfixTransportSessionEntry 11 }
ipfixTransportSessionOptionsTemplateRefreshTimeout OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On Exporters, this object contains the time in seconds
after which IPFIX Options Templates are resent by the
Exporter.
On Collectors, this object contains the lifetime in seconds
after which an Options Template becomes invalid when it is
not received again within this lifetime.
This object is only valid if ipfixTransportSessionProtocol
has the value 17 (UDP). In all other cases the value MUST
be zero."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 10.3.6 and 10.3.7."
::= { ipfixTransportSessionEntry 12 }
ipfixTransportSessionTemplateRefreshPacket OBJECT-TYPE
SYNTAX Unsigned32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 26]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"On Exporters, this object contains the number of exported
IPFIX Messages after which IPFIX Templates are resent
by the Exporter.
On Collectors, this object contains the lifetime in number
of exported IPFIX Messages after which a Template becomes
invalid when it is not received again within this lifetime.
This object is only valid if ipfixTransportSessionProtocol
has the value 17 (UDP). In all other cases the value MUST
be zero."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 10.3.6 and 10.3.7."
::= { ipfixTransportSessionEntry 13 }
ipfixTransportSessionOptionsTemplateRefreshPacket OBJECT-TYPE
SYNTAX Unsigned32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On Exporters, this object contains the number of exported
IPFIX Messages after which IPFIX Options Templates are
resent by the Exporter.
On Collectors, this object contains the lifetime in number
of exported IPFIX Messages after which an Options Template
becomes invalid when it is not received again within this
lifetime.
This object is only valid if ipfixTransportSessionProtocol
has the value 17 (UDP). In all other cases the value MUST
be zero."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 10.3.6 and 10.3.7."
::= { ipfixTransportSessionEntry 14 }
ipfixTransportSessionIpfixVersion OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 27]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"On Exporters the object contains the version number of the
IPFIX protocol that the Exporter uses to export its data in
this Transport Session.
On Collectors the object contains the version number of the
IPFIX protocol it receives for this Transport Session.
If IPFIX Messages of different IPFIX protocol versions are
transmitted or received in this Transport Session, this
object contains the maximum version number."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.1."
::= { ipfixTransportSessionEntry 15 }
ipfixTransportSessionStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
inactive(1),
active(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a Transport Session. This object can have the
following values:
unknown(0)
This value MUST be used if the status of the
Transport Session cannot be detected by the equipment.
This value should be avoided as far as possible.
inactive(1)
This value MUST be used for Transport Sessions that
are specified in the system but are not currently active.
The value can be used, e.g., for Transport Sessions that
are backup (secondary) sessions in a Transport Session
group.
active(2)
This value MUST be used for Transport Sessions that are
currently active and transmitting or receiving data."
::= { ipfixTransportSessionEntry 16 }
Dietz, et al. Standards Track [Page 28]
^L
RFC 5815 IPFIX MIB April 2010
--------------------------------------------------------------------
-- 1.1.2: Template Table
--------------------------------------------------------------------
ipfixTemplateTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the Templates and Options Templates that
are transmitted by the Exporting Process or received by the
Collecting Process.
The table contains the Templates and Options Templates that
are received or used for exporting data for a given
Transport Session group and Observation Domain.
Withdrawn or invalidated (Options) Template MUST be removed
from this table."
::= { ipfixMainObjects 2 }
ipfixTemplateEntry OBJECT-TYPE
SYNTAX IpfixTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixTemplateTable."
INDEX {
ipfixTransportSessionIndex,
ipfixTemplateObservationDomainId,
ipfixTemplateId
}
::= { ipfixTemplateTable 1 }
IpfixTemplateEntry ::=
SEQUENCE {
ipfixTemplateObservationDomainId Unsigned32,
ipfixTemplateId Unsigned32,
ipfixTemplateSetId Unsigned32,
ipfixTemplateAccessTime DateAndTime
}
Dietz, et al. Standards Track [Page 29]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateObservationDomainId OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Id of the Observation Domain for which this Template
is defined. This value is used when sending IPFIX Messages.
The special value of 0 indicates that the Data Records
exported with this (Option Template) cannot be applied to a
single Observation Domain."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.1."
::= { ipfixTemplateEntry 1 }
ipfixTemplateId OBJECT-TYPE
SYNTAX Unsigned32 (256..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This number indicates the Template Id in the IPFIX
Message. Values from 0 to 255 are not allowed for Template
Ids."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.4.1."
::= { ipfixTemplateEntry 2 }
ipfixTemplateSetId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This number indicates the Set Id of the Template. This
object allows to easily retrieve the Template type.
Currently, there are two values defined. The value 2 is
used for Sets containing Template definitions. The value 3
is used for Sets containing Options Template definitions."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.3.2."
::= { ipfixTemplateEntry 3 }
Dietz, et al. Standards Track [Page 30]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateAccessTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the Transport Session is in exporting mode
(ipfixTransportSessionDeviceMode) the time when this
(Options) Template was last sent to the Collector(s).
In the specific case of UDP as transport protocol, this
time is used to know when a retransmission of the
(Options) Template is needed.
If it is in collecting mode, this object contains the
time when this (Options) Template was last received from
the Exporter. In the specific case of UDP as transport
protocol, this time is used to know when this (Options)
Template times out and thus is no longer valid."
::= { ipfixTemplateEntry 4 }
--------------------------------------------------------------------
-- 1.1.3: Exported Template Definition Table
--------------------------------------------------------------------
ipfixTemplateDefinitionTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixTemplateDefinitionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"On Exporters, this table lists the (Options) Template fields
of which a (Options) Template is defined. It defines the
(Options) Template given in the ipfixTemplateId specified in
the ipfixTemplateTable.
On Collectors, this table lists the (Options) Template fields
of which a (Options) Template is defined. It defines the
(Options) Template given in the ipfixTemplateId specified in
the ipfixTemplateTable."
::= { ipfixMainObjects 3 }
ipfixTemplateDefinitionEntry OBJECT-TYPE
SYNTAX IpfixTemplateDefinitionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixTemplateDefinitionTable."
Dietz, et al. Standards Track [Page 31]
^L
RFC 5815 IPFIX MIB April 2010
INDEX {
ipfixTransportSessionIndex,
ipfixTemplateObservationDomainId,
ipfixTemplateId,
ipfixTemplateDefinitionIndex
}
::= { ipfixTemplateDefinitionTable 1 }
IpfixTemplateDefinitionEntry ::=
SEQUENCE {
ipfixTemplateDefinitionIndex Unsigned32,
ipfixTemplateDefinitionIeId Unsigned32,
ipfixTemplateDefinitionIeLength Unsigned32,
ipfixTemplateDefinitionEnterpriseNumber Unsigned32,
ipfixTemplateDefinitionFlags BITS
}
ipfixTemplateDefinitionIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ipfixTemplateDefinitionIndex specifies the order in
which the Information Elements are used in the (Options)
Template Record.
Since a Template Record can contain a maximum of 65535
Information Elements, the index is limited to this value."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 3.4.1 and 3.4.2."
::= { ipfixTemplateDefinitionEntry 1 }
ipfixTemplateDefinitionIeId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the Information Element Id at position
ipfixTemplateDefinitionIndex in the (Options) Template
ipfixTemplateId. This implicitly specifies the data type
of the Information Element. The elements are registered
at IANA. A current list of assignments can be found at
<http://www.iana.org/assignments/ipfix>"
Dietz, et al. Standards Track [Page 32]
^L
RFC 5815 IPFIX MIB April 2010
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.2.
RFC 5102, Information Model for IP Flow Information Export."
::= { ipfixTemplateDefinitionEntry 2 }
ipfixTemplateDefinitionIeLength OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the length of the Information Element Id at
position ipfixTemplateDefinitionIndex in the (Options)
Template ipfixTemplateId."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.2.
RFC 5102, Information Model for IP Flow Information Export."
::= { ipfixTemplateDefinitionEntry 3 }
ipfixTemplateDefinitionEnterpriseNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IANA enterprise number of the authority defining the
Information Element identifier in this Template Record.
Enterprise numbers are assigned by IANA. A current list of
all assignments is available from
<http://www.iana.org/assignments/enterprise-numbers/>.
This object must be zero(0) for all standard Information
Elements registered with IANA. A current list of these
elements is available from
<http://www.iana.org/assignments/ipfix/ipfix.xhtml>."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Section 3.2.
RFC 5102, Information Model for IP Flow Information Export."
::= { ipfixTemplateDefinitionEntry 4 }
Dietz, et al. Standards Track [Page 33]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateDefinitionFlags OBJECT-TYPE
SYNTAX BITS {
scope(0),
flowKey(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This bitmask indicates special attributes for the
Information Element:
scope(0)
This Information Element is used for scope.
flowKey(1)
This Information Element is a Flow Key.
Thus, we get the following values for an Information Element:
If neither bit scope(0) nor bit flowKey(1) are set
The Information Element is neither used for scoping nor
as Flow Key.
If only bit scope(0) is set
The Information Element is used for scoping.
If only bit flowKey(1) is set
The Information Element is used as Flow Key.
Both bit scope(0) and flowKey(1) MUST NOT be set at the same
time. This combination is not allowed."
REFERENCE
"RFC 5101, Specification of the IP Flow Information
Export (IPFIX) Protocol for the Exchange of IP Traffic Flow
Information, Sections 2 and 3.4.2.1.
RFC 5102, Information Model for IP Flow Information Export."
::= { ipfixTemplateDefinitionEntry 5 }
--------------------------------------------------------------------
-- 1.1.4: Export Table
--------------------------------------------------------------------
ipfixExportTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixExportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all exports of an IPFIX device.
Dietz, et al. Standards Track [Page 34]
^L
RFC 5815 IPFIX MIB April 2010
On Exporters, this table contains all exports grouped by
Transport Session, Observation Domain Id, Template Id, and
Metering Process represented by the
ipfixMeteringProcessCacheId. Thanks to the ipfixExportIndex,
the exports can group one or more Transport Sessions to
achieve a special functionality like failover management,
load-balancing, etc. The entries with the same
ipfixExportIndex, ipfixObservationDomainId,
and ipfixMeteringProcessCacheId define a Transport
Session group. If the Exporter does not use Transport
Session grouping, then each ipfixExportIndex contains a
single ipfixMeteringProcessCacheId and thus a singe
Transport Session, and this session MUST have the member
type primary(1). Transport Sessions referenced in this
table MUST have the ipfixTransportSessionDeviceMode
exporting(1).
On Collectors, this table is not needed."
::= { ipfixMainObjects 4 }
ipfixExportEntry OBJECT-TYPE
SYNTAX IpfixExportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixExportTable."
INDEX {
ipfixExportIndex,
ipfixMeteringProcessCacheId,
ipfixTransportSessionIndex
}
::= { ipfixExportTable 1 }
IpfixExportEntry ::=
SEQUENCE {
ipfixExportIndex Unsigned32,
ipfixExportMemberType INTEGER
}
ipfixExportIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in
the ipfixExportTable. The value is expected
to remain constant from a re-initialization of the entity's
network management agent to the next re-initialization.
Dietz, et al. Standards Track [Page 35]
^L
RFC 5815 IPFIX MIB April 2010
A common ipfixExportIndex between two entries from this
table expresses that there is a relationship between the
Transport Sessions in ipfixTransportSessionIndex. The type
of relationship is expressed by the value of
ipfixExportMemberType."
::= { ipfixExportEntry 1 }
ipfixExportMemberType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
primary(1),
secondary(2),
parallel(3),
loadBalancing(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of a member Transport Session in a Transport
Session group (identified by the value of ipfixExportIndex,
ipfixObservationDomainId, and ipfixMeteringProcessCacheId).
The following values are valid:
unknown(0)
This value MUST be used if the status of the group
membership cannot be detected by the equipment. This
value should be avoided as far as possible.
primary(1)
This value is used for a group member that is used as
the primary target of an Exporter. Other group members
(with the same ipfixExportIndex and
ipfixMeteringProcessCacheId) MUST NOT have the value
primary(1) but MUST have the value secondary(2).
This value MUST also be specified if the Exporter does
not support Transport Session grouping. In this case,
the group contains only one Transport Session.
secondary(2)
This value is used for a group member that is used as a
secondary target of an Exporter. The Exporter will use
one of the targets specified as secondary(2) within the
same Transport Session group when the primary target is
not reachable.
Dietz, et al. Standards Track [Page 36]
^L
RFC 5815 IPFIX MIB April 2010
parallel(3)
This value is used for a group member that is used for
duplicate exporting, i.e., all group members identified
by the ipfixExportIndex are exporting the same Records
in parallel. This implies that all group members MUST
have the same membertype parallel(3).
loadBalancing(4)
This value is used for a group member that is used
as one target for load-balancing. This means that a
Record is sent to one of the group members in this
group identified by ipfixExportIndex.
This implies that all group members MUST have the same
membertype loadBalancing(4)."
::= { ipfixExportEntry 2 }
--------------------------------------------------------------------
-- 1.1.5: Metering Process Table
--------------------------------------------------------------------
ipfixMeteringProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixMeteringProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists so-called caches used at the Metering
Process to store the metering data of Flows observed at
the Observation Points given in the
ipfixObservationPointGroupReference. The table lists the
timeouts that specify when the cached metering data is
expired.
On Collectors, the table is not needed."
::= { ipfixMainObjects 5 }
ipfixMeteringProcessEntry OBJECT-TYPE
SYNTAX IpfixMeteringProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixMeteringProcessTable."
INDEX { ipfixMeteringProcessCacheId }
::= { ipfixMeteringProcessTable 1 }
Dietz, et al. Standards Track [Page 37]
^L
RFC 5815 IPFIX MIB April 2010
IpfixMeteringProcessEntry ::=
SEQUENCE {
ipfixMeteringProcessCacheId Unsigned32,
ipfixMeteringProcessObservationPointGroupRef Unsigned32,
ipfixMeteringProcessCacheActiveTimeout Unsigned32,
ipfixMeteringProcessCacheInactiveTimeout Unsigned32
}
ipfixMeteringProcessCacheId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in the
ipfixMeterinProcessTable. The value is expected to remain
constant from a re-initialization of the entity's network
management agent to the next re-initialization."
::= { ipfixMeteringProcessEntry 1 }
ipfixMeteringProcessObservationPointGroupRef OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Observation Point Group Id that links this table entry
to the ipfixObservationPointTable. The matching
ipfixObservationPointGroupId in that table gives the
Observation Points used in that cache. If the Observation
Points are unknown, the
ipfixMeteringProcessObservationPointGroupRef MUST be zero."
::= { ipfixMeteringProcessEntry 2 }
ipfixMeteringProcessCacheActiveTimeout OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On the Exporter, this object contains the time after which a
Flow is expired (and a Data Record for the template is sent)
even though packets matching this Flow are still received by
the Metering Process. If this value is 0, the Flow is not
prematurely expired."
REFERENCE
"RFC 5470, Architecture for IP Flow Information Export,
Section 5.1.1, item 3."
::= { ipfixMeteringProcessEntry 3 }
Dietz, et al. Standards Track [Page 38]
^L
RFC 5815 IPFIX MIB April 2010
ipfixMeteringProcessCacheInactiveTimeout OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On the Exporter. this object contains the time after which a
Flow is expired (and a Data Record for the template is sent)
when no packets matching this Flow are received by the
Metering Process for the given number of seconds. If this
value is zero, the Flow is expired immediately, i.e., a Data
Record is sent for every packet received by the Metering
Process."
REFERENCE
"RFC 5470, Architecture for IP Flow Information Export,
Section 5.1.1, item 1"
::= { ipfixMeteringProcessEntry 4 }
--------------------------------------------------------------------
-- 1.1.6: Observation Point Table
--------------------------------------------------------------------
ipfixObservationPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixObservationPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the Observation Points used within an
Exporter by the Metering Process. The index
ipfixObservationPointGroupId groups Observation Points
and is referenced in the Metering Process table.
On Collectors this table is not needed."
::= { ipfixMainObjects 6 }
ipfixObservationPointEntry OBJECT-TYPE
SYNTAX IpfixObservationPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixObservationPointTable."
INDEX {
ipfixObservationPointGroupId,
ipfixObservationPointIndex
}
::= { ipfixObservationPointTable 1 }
Dietz, et al. Standards Track [Page 39]
^L
RFC 5815 IPFIX MIB April 2010
IpfixObservationPointEntry ::=
SEQUENCE {
ipfixObservationPointGroupId Unsigned32,
ipfixObservationPointIndex Unsigned32,
ipfixObservationPointObservationDomainId Unsigned32,
ipfixObservationPointPhysicalEntity PhysicalIndexOrZero,
ipfixObservationPointPhysicalInterface InterfaceIndexOrZero,
ipfixObservationPointPhysicalEntityDirection INTEGER
}
ipfixObservationPointGroupId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in the
ipfixObservationPointTable. The value is expected to remain
constant from a re-initialization of the entity's network
management agent to the next re-initialization.
This index represents a group of Observation Points.
The special value of 0 MUST NOT be used within this table
but is reserved for the usage in the
ipfixMeteringProcessTable. An index of 0 for the
ipfixObservationPointGroupReference index in that table
indicates that an Observation Point is unknown or
unspecified for a Metering Process cache."
::= { ipfixObservationPointEntry 1 }
ipfixObservationPointIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in the
ipfixObservationPointTable. The value is expected to remain
constant from a re-initialization of the entity's network
management agent to the next re-initialization.
This index represents a single Observation Point in an
Observation Point group."
::= { ipfixObservationPointEntry 2 }
ipfixObservationPointObservationDomainId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 40]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The Id of the Observation Domain in which this
Observation Point is included.
The special value of 0 indicates that the Observation
Points within this group cannot be applied to a single
Observation Domain."
REFERENCE
"RFC 5101, Specification of the IP Flow Information Export
(IPFIX) Protocol for the Exchange of IP
Traffic Flow Information, Section 3.1."
::= { ipfixObservationPointEntry 3 }
ipfixObservationPointPhysicalEntity OBJECT-TYPE
SYNTAX PhysicalIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the index of a physical entity in
the ENTITY MIB. This physical entity is the given
Observation Point. If such a physical entity cannot be
specified or is not known, then the object is zero."
::= { ipfixObservationPointEntry 4 }
ipfixObservationPointPhysicalInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the index of a physical interface in
the IF MIB. This physical interface is the given
Observation Point. If such a physical interface cannot be
specified or is not known, then the object is zero.
This object MAY be used stand alone or in addition to
ipfixObservationPointPhysicalEntity. If
ipfixObservationPointPhysicalEntity is not zero, this object
MUST point to the same physical interface that is
referenced in ipfixObservationPointPhysicalEntity.
Otherwise, it may reference any interface in the IF MIB."
::= { ipfixObservationPointEntry 5 }
Dietz, et al. Standards Track [Page 41]
^L
RFC 5815 IPFIX MIB April 2010
ipfixObservationPointPhysicalEntityDirection OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ingress(1),
egress(2),
both(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the Flow that is monitored on the given
physical entity. The following values are valid:
unknown(0)
This value MUST be used if a direction is not
known for the given physical entity.
ingress(1)
This value is used for monitoring incoming Flows on the
given physical entity.
egress(2)
This value is used for monitoring outgoing Flows on the
given physical entity.
both(3)
This value is used for monitoring incoming and outgoing
Flows on the given physical entity."
::= { ipfixObservationPointEntry 6 }
--------------------------------------------------------------------
-- 1.1.7: Selection Process Table
--------------------------------------------------------------------
ipfixSelectionProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixSelectionProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Selector Functions connected to a
Metering Process by the index ipfixMeteringProcessCacheId.
The Selector Functions are grouped into Selection Processes
by the ipfixSelectionProcessIndex. The Selector Functions
are applied within the Selection Process to the packets
observed for the given Metering Process cache in increasing
order implied by the ipfixSelectionProcessSelectorIndex.
This means Selector Functions with lower
ipfixSelectionProcessSelectorIndex are applied first. The
remaining packets are accounted for in Flow Records.
Dietz, et al. Standards Track [Page 42]
^L
RFC 5815 IPFIX MIB April 2010
Since IPFIX does not define any Selector Function (except
selecting every packet), this is a placeholder for future
use and a guideline for implementing enterprise-specific
Selector Function objects.
The following object tree should visualize how the
Selector Function objects should be implemented:
ipfixSelectorFunctions
|
+- ipfixFuncSelectAll
| |
| +- ipfixFuncSelectAllAvail (is the function available?)
|
+- ipfixFuncF2
| |
| +- ipfixFuncF2Avail (is the function F2 available?)
| |
| +- ipfixFuncF2Parameters (a table with parameters)
...
|
+- ipfixFunFn...
If a Selector Function takes parameters, the MIB should
contain a table with an entry for each set of parameters
used at the Exporter."
::= { ipfixMainObjects 7 }
ipfixSelectionProcessEntry OBJECT-TYPE
SYNTAX IpfixSelectionProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixSelectionProcessTable."
INDEX {
ipfixMeteringProcessCacheId,
ipfixSelectionProcessIndex,
ipfixSelectionProcessSelectorIndex
}
::= { ipfixSelectionProcessTable 1 }
IpfixSelectionProcessEntry ::= SEQUENCE {
ipfixSelectionProcessIndex Unsigned32,
ipfixSelectionProcessSelectorIndex Unsigned32,
ipfixSelectionProcessSelectorFunction OBJECT IDENTIFIER
}
Dietz, et al. Standards Track [Page 43]
^L
RFC 5815 IPFIX MIB April 2010
ipfixSelectionProcessIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Locally arbitrary, but unique identifier of an entry in the
ipfixSelectionProcessTable. The value is expected to remain
constant from a re-initialization of the entity's network
management agent to the next re-initialization."
::= { ipfixSelectionProcessEntry 1 }
ipfixSelectionProcessSelectorIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index specifying the order in which the referenced
ipfixSelctionProcessSelectorFunctions are applied to the
observed packet stream within the given Selection Process
(identified by the ipfixSelectionProcessIndex). The
Selector Functions are applied in increasing order, i.e.,
Selector Functions with lower index are applied first."
::= { ipfixSelectionProcessEntry 2 }
ipfixSelectionProcessSelectorFunction OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The pointer to the Selector Function used at position
ipfixSelectionProcessSelectorIndex in the list of Selector
Functions for the Metering Process cache specified by the
index ipfixMeteringProcessCacheId and for the given
Selection Process (identified by the
ipfixSelectionProcessIndex).
This usually points to an object in the IPFIX SELECTOR MIB.
If the Selector Function does not take parameters, then it
MUST point to the root of the function subtree. If the
function takes parameters, then it MUST point to an entry
in the parameter table of the Selector Function."
::= { ipfixSelectionProcessEntry 3 }
Dietz, et al. Standards Track [Page 44]
^L
RFC 5815 IPFIX MIB April 2010
--------------------------------------------------------------------
-- 1.2.1: Transport Session Statistics Table
--------------------------------------------------------------------
ipfixTransportSessionStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixTransportSessionStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists Transport Sessions statistics between
Exporting Processes and Collecting Processes."
::= { ipfixStatistics 1 }
ipfixTransportSessionStatsEntry OBJECT-TYPE
SYNTAX IpfixTransportSessionStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixTransportSessionStatsTable."
AUGMENTS { ipfixTransportSessionEntry }
::= { ipfixTransportSessionStatsTable 1 }
IpfixTransportSessionStatsEntry ::=
SEQUENCE {
ipfixTransportSessionRate Gauge32,
ipfixTransportSessionPackets Counter64,
ipfixTransportSessionBytes Counter64,
ipfixTransportSessionMessages Counter64,
ipfixTransportSessionDiscardedMessages Counter64,
ipfixTransportSessionRecords Counter64,
ipfixTransportSessionTemplates Counter64,
ipfixTransportSessionOptionsTemplates Counter64,
ipfixTransportSessionDiscontinuityTime TimeStamp
}
ipfixTransportSessionRate OBJECT-TYPE
SYNTAX Gauge32
UNITS "bytes/second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes per second received by the
Collector or transmitted by the Exporter. A
value of zero (0) means that no packets were sent or
received, yet. This object is updated every second."
::= { ipfixTransportSessionStatsEntry 1 }
Dietz, et al. Standards Track [Page 45]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTransportSessionPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received by the Collector
or transmitted by the Exporter.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 2 }
ipfixTransportSessionBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes received by the Collector
or transmitted by the Exporter.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 3 }
ipfixTransportSessionMessages OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IPFIX Messages received by the
Collector or transmitted by the Exporter.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 4 }
ipfixTransportSessionDiscardedMessages OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 46]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The number of received IPFIX Message that are malformed,
cannot be decoded, are received in the wrong order, or are
missing according to the sequence number.
If used at the Exporter, the number of messages that could
not be sent due to, e.g., internal buffer overflows, network
congestion, or routing issues.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 5 }
ipfixTransportSessionRecords OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Records received by the Collector or
transmitted by the Exporter.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 6 }
ipfixTransportSessionTemplates OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Templates received or transmitted.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 7 }
ipfixTransportSessionOptionsTemplates OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 47]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The number of Options Templates received or transmitted.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTransportSessionDiscontinuityTime."
::= { ipfixTransportSessionStatsEntry 8 }
ipfixTransportSessionDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the most recent occasion at which
one or more of the Transport Session counters suffered a
discontinuity.
A value of zero indicates no such discontinuity has
occurred since the last re-initialization of the local
management subsystem."
::= { ipfixTransportSessionStatsEntry 9 }
--------------------------------------------------------------------
-- 1.2.2: Template Statistics Table
--------------------------------------------------------------------
ipfixTemplateStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixTemplateStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists statistics objects per Template."
::= { ipfixStatistics 2 }
ipfixTemplateStatsEntry OBJECT-TYPE
SYNTAX IpfixTemplateStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixTemplateStatsTable."
AUGMENTS { ipfixTemplateEntry }
::= { ipfixTemplateStatsTable 1 }
IpfixTemplateStatsEntry ::=
SEQUENCE {
ipfixTemplateDataRecords Counter64,
ipfixTemplateDiscontinuityTime TimeStamp
}
Dietz, et al. Standards Track [Page 48]
^L
RFC 5815 IPFIX MIB April 2010
ipfixTemplateDataRecords OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Records that are transmitted or received
per Template.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of
ipfixTemplateDiscontinuityTime."
::= { ipfixTemplateStatsEntry 1 }
ipfixTemplateDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the most recent occasion at which
the Template counter suffered a discontinuity.
A value of zero indicates no such discontinuity has
occurred since the last re-initialization of the local
management subsystem."
::= { ipfixTemplateStatsEntry 2 }
--------------------------------------------------------------------
-- 1.2.3: Metering Process Statistics Table
--------------------------------------------------------------------
ipfixMeteringProcessStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixMeteringProcessStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists statistic objects that have data per
Metering Process cache.
On Collectors, this table is not needed."
::= { ipfixStatistics 3 }
Dietz, et al. Standards Track [Page 49]
^L
RFC 5815 IPFIX MIB April 2010
ipfixMeteringProcessStatsEntry OBJECT-TYPE
SYNTAX IpfixMeteringProcessStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixMeteringProcessStatsTable."
AUGMENTS { ipfixMeteringProcessEntry }
::= { ipfixMeteringProcessStatsTable 1 }
IpfixMeteringProcessStatsEntry ::=
SEQUENCE {
ipfixMeteringProcessCacheActiveFlows Gauge32,
ipfixMeteringProcessCacheUnusedCacheEntries Gauge32,
ipfixMeteringProcessCacheDataRecords Counter64,
ipfixMeteringProcessCacheDiscontinuityTime TimeStamp
}
ipfixMeteringProcessCacheActiveFlows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Flows currently active at this cache."
::= { ipfixMeteringProcessStatsEntry 1 }
ipfixMeteringProcessCacheUnusedCacheEntries OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of unused cache entries."
::= { ipfixMeteringProcessStatsEntry 2 }
ipfixMeteringProcessCacheDataRecords OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Records generated.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixTemplateDiscontinuityTime."
::= { ipfixMeteringProcessStatsEntry 3 }
Dietz, et al. Standards Track [Page 50]
^L
RFC 5815 IPFIX MIB April 2010
ipfixMeteringProcessCacheDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the most recent occasion at which
the Metering Process counter suffered a discontinuity.
A value of zero indicates no such discontinuity has
occurred since the last re-initialization of the local
management subsystem."
::= { ipfixMeteringProcessStatsEntry 4 }
--------------------------------------------------------------------
-- 1.2.4: Selection Process Statistics Table
--------------------------------------------------------------------
ipfixSelectionProcessStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpfixSelectionProcessStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains statistics for the Selector Functions
connected to Metering Process by the index
ipfixMeteringProcessCacheId.
The indexes MUST match an entry in the
ipfixSelectionProcessTable."
::= { ipfixStatistics 4 }
ipfixSelectionProcessStatsEntry OBJECT-TYPE
SYNTAX IpfixSelectionProcessStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the ipfixSelectionProcessStatsTable."
AUGMENTS { ipfixSelectionProcessEntry }
::= { ipfixSelectionProcessStatsTable 1 }
IpfixSelectionProcessStatsEntry ::= SEQUENCE {
ipfixSelectionProcessStatsPacketsObserved Counter64,
ipfixSelectionProcessStatsPacketsDropped Counter64,
ipfixSelectionProcessStatsDiscontinuityTime TimeStamp
}
ipfixSelectionProcessStatsPacketsObserved OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
Dietz, et al. Standards Track [Page 51]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The number of packets observed at the entry point of the
function. The entry point may be the Observation Point or
the exit point of another Selector Function.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixSelectionProcessStatsDiscontinuityTime."
::= { ipfixSelectionProcessStatsEntry 1 }
ipfixSelectionProcessStatsPacketsDropped OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets dropped while selecting packets.
Discontinuities in the value of this counter can occur at
re-initialization of the management system and at other
times as indicated by the value of
ipfixSelectionProcessStatsDiscontinuityTime."
::= { ipfixSelectionProcessStatsEntry 2 }
ipfixSelectionProcessStatsDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the most recent occasion at which
one or more of the Selector counters suffered a
discontinuity.
A value of zero indicates no such discontinuity has
occurred since the last re-initialization of the local
management subsystem."
::= { ipfixSelectionProcessStatsEntry 3 }
Dietz, et al. Standards Track [Page 52]
^L
RFC 5815 IPFIX MIB April 2010
--==================================================================
-- 2: Conformance Information
--==================================================================
ipfixCompliances OBJECT IDENTIFIER ::= { ipfixConformance 1 }
ipfixGroups OBJECT IDENTIFIER ::= { ipfixConformance 2 }
--------------------------------------------------------------------
-- 2.1: Compliance Statements
--------------------------------------------------------------------
ipfixCollectorCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"An implementation that builds an IPFIX Collector
that complies to this module MUST implement the objects
defined in the mandatory group ipfixCommonGroup.
The implementation of all objects in the other groups is
optional and depends on the corresponding functionality
implemented in the equipment.
An implementation that is compliant to this MIB module
is limited to use only the values TCP (6), UDP (17), and
SCTP (132) in the ipfixTransportSessionProtocol object
because these are the only protocol currently specified
for usage within IPFIX (see RFC 5101)."
MODULE -- this module
MANDATORY-GROUPS {
ipfixCommonGroup
}
GROUP ipfixCommonStatsGroup
DESCRIPTION
"These objects should be implemented if the statistics
function is implemented in the equipment."
::= { ipfixCompliances 1 }
ipfixExporterCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"An implementation that builds an IPFIX Exporter that
complies to this module MUST implement the objects defined
in the mandatory group ipfixCommonGroup. The implementation
of all other objects depends on the implementation of the
corresponding functionality in the equipment."
MODULE -- this module
Dietz, et al. Standards Track [Page 53]
^L
RFC 5815 IPFIX MIB April 2010
MANDATORY-GROUPS {
ipfixCommonGroup,
ipfixExporterGroup
}
GROUP ipfixCommonStatsGroup
DESCRIPTION
"These objects should be implemented if the statistics
function is implemented in the equipment."
GROUP ipfixExporterStatsGroup
DESCRIPTION
"These objects MUST be implemented if statistical functions
are implemented on the equipment."
::= { ipfixCompliances 2 }
--------------------------------------------------------------------
-- 2.2: MIB Grouping
--------------------------------------------------------------------
ipfixCommonGroup OBJECT-GROUP
OBJECTS {
ipfixTransportSessionProtocol,
ipfixTransportSessionSourceAddressType,
ipfixTransportSessionSourceAddress,
ipfixTransportSessionDestinationAddressType,
ipfixTransportSessionDestinationAddress,
ipfixTransportSessionSourcePort,
ipfixTransportSessionDestinationPort,
ipfixTransportSessionSctpAssocId,
ipfixTransportSessionDeviceMode,
ipfixTransportSessionTemplateRefreshTimeout,
ipfixTransportSessionOptionsTemplateRefreshTimeout,
ipfixTransportSessionTemplateRefreshPacket,
ipfixTransportSessionOptionsTemplateRefreshPacket,
ipfixTransportSessionIpfixVersion,
ipfixTransportSessionStatus,
ipfixTemplateSetId,
ipfixTemplateAccessTime,
ipfixTemplateDefinitionIeId,
ipfixTemplateDefinitionIeLength,
ipfixTemplateDefinitionEnterpriseNumber,
ipfixTemplateDefinitionFlags
}
STATUS current
Dietz, et al. Standards Track [Page 54]
^L
RFC 5815 IPFIX MIB April 2010
DESCRIPTION
"The main IPFIX objects."
::= { ipfixGroups 1 }
ipfixCommonStatsGroup OBJECT-GROUP
OBJECTS {
ipfixTransportSessionRate,
ipfixTransportSessionPackets,
ipfixTransportSessionBytes,
ipfixTransportSessionMessages,
ipfixTransportSessionDiscardedMessages,
ipfixTransportSessionRecords,
ipfixTransportSessionTemplates,
ipfixTransportSessionOptionsTemplates,
ipfixTransportSessionDiscontinuityTime,
ipfixTemplateDataRecords,
ipfixTemplateDiscontinuityTime
}
STATUS current
DESCRIPTION
"Common statistical objects."
::= { ipfixGroups 2 }
ipfixExporterGroup OBJECT-GROUP
OBJECTS {
ipfixExportMemberType,
ipfixMeteringProcessObservationPointGroupRef,
ipfixMeteringProcessCacheActiveTimeout,
ipfixMeteringProcessCacheInactiveTimeout,
ipfixObservationPointObservationDomainId,
ipfixObservationPointPhysicalEntity,
ipfixObservationPointPhysicalInterface,
ipfixObservationPointPhysicalEntityDirection,
ipfixSelectionProcessSelectorFunction
}
STATUS current
DESCRIPTION
"The main objects for Exporters."
::= { ipfixGroups 3 }
Dietz, et al. Standards Track [Page 55]
^L
RFC 5815 IPFIX MIB April 2010
ipfixExporterStatsGroup OBJECT-GROUP
OBJECTS {
ipfixMeteringProcessCacheActiveFlows,
ipfixMeteringProcessCacheUnusedCacheEntries,
ipfixMeteringProcessCacheDataRecords,
ipfixMeteringProcessCacheDiscontinuityTime,
ipfixSelectionProcessStatsPacketsObserved,
ipfixSelectionProcessStatsPacketsDropped,
ipfixSelectionProcessStatsDiscontinuityTime
}
STATUS current
DESCRIPTION
"The statistical objects for Exporters."
::= { ipfixGroups 4 }
END
8.2. IPFIX SELECTOR MIB Definition
IPFIX-SELECTOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, mib-2
FROM SNMPv2-SMI -- RFC2578
TruthValue
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF; -- RFC2580
ipfixSelectorMIB MODULE-IDENTITY
LAST-UPDATED "201003150000Z" -- 15 March 2010
ORGANIZATION "IETF IPFIX Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/ipfix-charter.html
Mailing Lists:
General Discussion: ipfix@ietf.org
To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
Archive:
http://www1.ietf.org/mail-archive/web/ipfix/current/index.html
Dietz, et al. Standards Track [Page 56]
^L
RFC 5815 IPFIX MIB April 2010
Editor:
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-128
Email: Thomas.Dietz@nw.neclab.eu
Atsushi Kobayashi
NTT Information Sharing Platform Laboratories
3-9-11 Midori-cho
Musashino-shi
180-8585
Japan
Phone: +81-422-59-3978
Email: akoba@nttv6.net
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Degem 1831
Belgium
Phone: +32 2 704 5622
Email: bclaise@cisco.com
Gerhard Muenz
Technische Universitaet Muenchen
Department of Informatics
Chair for Network Architectures and Services (I8)
Boltzmannstr. 3
85748 Garching
Germany
Phone: +49 89 289-18008
Email: muenz@net.in.tum.de
URI: http://www.net.in.tum.de/~muenz"
DESCRIPTION
"The IPFIX SELECTOR MIB module defines the standard
filtering and sampling functions that can be referenced in
the ipfixSelectorTable of the IPFIX MIB. The subtree
ipfixSelectorFunctions is a placeholder where all standard
filtering and sampling functions should be located.
The IPFIX SELECTOR MIB module is maintained by IANA and can
be extended through Expert Review [RFC5226], i.e., review by
one of a group of experts designated by an IETF Area
Dietz, et al. Standards Track [Page 57]
^L
RFC 5815 IPFIX MIB April 2010
Director. The group of experts MUST check the requested MIB
objects for completeness and accuracy of the description.
Requests for MIB objects that duplicate the functionality of
existing objects SHOULD be declined. The smallest available
OID SHOULD be assigned to a new MIB objects. The
specification of new MIB objects SHOULD follow the structure
specified in RFC 5815 and MUST be published using a
well-established and persistent publication medium. The
experts will initially be drawn from the Working Group
Chairs and document editors of the IPFIX and PSAMP Working
Groups.
Copyright (c) 2010 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD
License set forth in Section 4.c of the IETF Trust's
Legal Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
-- Revision history
REVISION "201003150000Z" -- 15 March 2010
DESCRIPTION
"Initial version, published as RFC 5815."
::= { mib-2 194 }
--******************************************************************
-- Top Level Structure of the MIB
--******************************************************************
ipfixSelectorObjects OBJECT IDENTIFIER
::= { ipfixSelectorMIB 1 }
ipfixSelectorConformance OBJECT IDENTIFIER
::= { ipfixSelectorMIB 2 }
--==================================================================
-- 1: Objects used by all IPFIX implementations
--==================================================================
--------------------------------------------------------------------
-- 1.1: Packet Selector Functions for IPFIX
--------------------------------------------------------------------
ipfixSelectorFunctions OBJECT IDENTIFIER
::= { ipfixSelectorObjects 1 }
Dietz, et al. Standards Track [Page 58]
^L
RFC 5815 IPFIX MIB April 2010
--------------------------------------------------------------------
-- 1.1.1: Function 1: Selecting All Packets
--------------------------------------------------------------------
ipfixFuncSelectAll OBJECT IDENTIFIER
::= { ipfixSelectorFunctions 1 }
ipfixFuncSelectAllAvail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the availability of the trivial
function of selecting all packets. This function is always
available."
::= { ipfixFuncSelectAll 1 }
--==================================================================
-- 2: Conformance Information
--==================================================================
ipfixSelectorCompliances OBJECT IDENTIFIER
::= { ipfixSelectorConformance 1 }
ipfixSelectorGroups OBJECT IDENTIFIER
::= { ipfixSelectorConformance 2 }
--------------------------------------------------------------------
-- 2.1: Compliance Statements
--------------------------------------------------------------------
ipfixSelectorBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"An implementation that builds an IPFIX Exporter that
complies to this module MUST implement the objects defined
in the mandatory group ipfixBasicGroup. The implementation
of all other objects depends on the implementation of the
corresponding functionality in the equipment."
MODULE -- this module
MANDATORY-GROUPS {
ipfixSelectorBasicGroup
}
::= { ipfixSelectorCompliances 1 }
--------------------------------------------------------------------
-- 2.2: MIB Grouping
--------------------------------------------------------------------
ipfixSelectorBasicGroup OBJECT-GROUP
OBJECTS {
ipfixFuncSelectAllAvail
}
Dietz, et al. Standards Track [Page 59]
^L
RFC 5815 IPFIX MIB April 2010
STATUS current
DESCRIPTION
"The main IPFIX objects."
::= { ipfixSelectorGroups 1 }
END
9. Security Considerations
There are no management objects defined in this MIB module that have
a MAX-ACCESS clause of read-write and/or read-create. So, if these
MIB modules are implemented correctly, then there is no risk that an
intruder can alter or create any management objects of these MIB
modules via direct SNMP SET operations.
Some of the readable objects in these MIB modules (i.e., objects with
a MAX-ACCESS other than not-accessible) may be considered sensitive
or vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. These are the tables and objects and their
sensitivity/vulnerability:
o ipfixTransportSessionTable - contains configuration data that
might be sensitive because objects in this table may reveal
information about the network infrastructure
o ipfixExportTable - contains configuration data that might be
sensitive because object in this table may reveal information
about the network infrastructure as well
o ipfixMeteringProcessTable - contains configuration data that might
be sensitive because objects in this table may reveal information
about the IPFIX Device itself
o ipfixObservationPointTable - contains configuration data that
might be sensitive because objects in this table may reveal
information about the IPFIX Device itself and the network
infrastructure
o ipfixSelectorFunctions - currently contains no sensitive data but
might want to be secured anyway since it may contain sensitive
data in a future version
All other objects and tables contain no data that is considered
sensitive.
Dietz, et al. Standards Track [Page 60]
^L
RFC 5815 IPFIX MIB April 2010
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in these MIB modules.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410] Section 8), including
full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of these MIB modules is properly configured to give access
to the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
10. IANA Considerations
The MIB module in this document uses the following IANA-assigned
OBJECT IDENTIFIER values recorded in the SMI Numbers registry:
Descriptor OBJECT IDENTIFIER value
---------- -----------------------
ipfixMIB { mib-2 193 }
ipfixSelectorMIB { mib-2 194 }
Further on, the whole IPFIX SELECTOR MIB module is maintained by
IANA. Additions to this MIB module are subject to Expert Review
[RFC5226], i.e., review by one of a group of experts designated by an
IETF Area Director. The group of experts MUST check the requested
MIB objects for completeness and accuracy of the description.
Requests for MIB objects that duplicate the functionality of existing
objects SHOULD be declined. The smallest available OID SHOULD be
assigned to new MIB objects. The specification of new MIB objects
SHOULD follow the structure specified in Section 6 and MUST be
published using a well-established and persistent publication medium.
The experts will initially be drawn from the Working Group Chairs and
document editors of the IPFIX and PSAMP Working Groups.
11. Acknowledgments
This document is a product of the IPFIX Working Group. The authors
would like to thank the following persons: Paul Aitken for his
detailed review, Dan Romascanu and the MIB doctors, and many more,
for the technical reviews and feedback.
Dietz, et al. Standards Track [Page 61]
^L
RFC 5815 IPFIX MIB April 2010
12. References
12.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2",
STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC4001] Daniele, M., Haberman, B., Routhier, S., and J.
Schoenwaelder, "Textual Conventions for Internet Network
Addresses", RFC 4001, February 2005.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
MIB", RFC 2863, June 2000.
[RFC3873] Pastor, J. and M. Belinchon, "Stream Control Transmission
Protocol (SCTP) Management Information Base (MIB)",
RFC 3873, September 2004.
[RFC4133] Bierman, A. and K. McCloghrie, "Entity MIB (Version 3)",
RFC 4133, August 2005.
[RFC5101] Claise, B., "Specification of the IP Flow Information
Export (IPFIX) Protocol for the Exchange of IP Traffic
Flow Information", RFC 5101, January 2008.
[RFC5102] Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
Meyer, "Information Model for IP Flow Information Export",
RFC 5102, January 2008.
[RFC5226] Narten, T. and H. Alvestrand, "Guidelines for Writing an
IANA Considerations Section in RFCs", BCP 26, RFC 5226,
May 2008.
Dietz, et al. Standards Track [Page 62]
^L
RFC 5815 IPFIX MIB April 2010
12.2. Informative References
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
[RFC3917] Quittek, J., Zseby, T., Claise, B., and S. Zander,
"Requirements for IP Flow Information Export (IPFIX)",
RFC 3917, October 2004.
[RFC5470] Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek,
"Architecture for IP Flow Information Export", RFC 5470,
March 2009.
[RFC5472] Zseby, T., Boschi, E., Brownlee, N., and B. Claise, "IP
Flow Information Export (IPFIX) Applicability", RFC 5472,
March 2009.
[RFC5474] Duffield, N., Chiou, D., Claise, B., Greenberg, A.,
Grossglauser, M., and J. Rexford, "A Framework for Packet
Selection and Reporting", RFC 5474, March 2009.
[RFC5475] Zseby, T., Molina, M., Duffield, N., Niccolini, S., and F.
Raspall, "Sampling and Filtering Techniques for IP Packet
Selection", RFC 5475, March 2009.
[RFC5476] Claise, B., Johnson, A., and J. Quittek, "Packet Sampling
(PSAMP) Protocol Specifications", RFC 5476, March 2009.
Dietz, et al. Standards Track [Page 63]
^L
RFC 5815 IPFIX MIB April 2010
Authors' Addresses
Thomas Dietz (editor)
NEC Europe, Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-128
EMail: Thomas.Dietz@nw.neclab.eu
Atsushi Kobayashi
NTT Information Sharing Platform Laboratories
3-9-11 Midori-cho
Musashino-shi, Tokyo 180-8585
JA
Phone: +81-422-59-3978
EMail: akoba@nttv6.net
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Degem 1831
BE
Phone: +32 2 704 5622
EMail: bclaise@cisco.com
Gerhard Muenz
Technische Universitaet Muenchen
Department of Informatics
Chair for Network Architectures and Services (I8)
Boltzmannstr. 3
Garching 85748
DE
Phone: +49 89 289-18008
EMail: muenz@net.in.tum.de
URI: http://www.net.in.tum.de/~muenz
Dietz, et al. Standards Track [Page 64]
^L
|