1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
|
Internet Engineering Task Force (IETF) L. Berger
Request for Comments: 6005 LabN
Category: Standards Track D. Fedyk
ISSN: 2070-1721 Alcatel-Lucent
October 2010
Generalized MPLS (GMPLS) Support for Metro Ethernet Forum
and G.8011 User Network Interface (UNI)
Abstract
This document describes a method for controlling two specific types
of Ethernet switching via a GMPLS-based User Network Interface (UNI).
This document supports the types of switching required by the
Ethernet services that have been defined in the context of the Metro
Ethernet Forum (MEF) and International Telecommunication Union (ITU)
G.8011. This document is the UNI companion to "Generalized MPLS
(GMPLS) Support for Metro Ethernet Forum and G.8011 Ethernet Service
Switching". This document does not define or limit the underlying
intra-domain or Internal NNI (I-NNI) technology used to support the
UNI.
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Further information on
Internet Standards is available in Section 2 of RFC 5741.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc6005.
Berger & Fedyk Standards Track [Page 1]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
Copyright Notice
Copyright (c) 2010 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction ....................................................3
1.1. Overview ...................................................4
1.2. Conventions Used in This Document ..........................5
2. Common Signaling Support ........................................5
2.1. UNI Addressing .............................................5
2.2. Ethernet Endpoint (UNI) Identification .....................6
2.2.1. Address Resolution ..................................6
2.3. Connection Identification ..................................7
3. EPL Service .....................................................7
4. EVPL Service ....................................................7
4.1. Egress VLAN ID Control and VLAN ID Preservation ............7
5. IANA Considerations .............................................8
5.1. Error Value: Routing Problem/Unknown Endpoint ..............8
6. Security Considerations .........................................8
7. References ......................................................8
7.1. Normative References .......................................8
7.2. Informative References .....................................9
Acknowledgments ....................................................9
Berger & Fedyk Standards Track [Page 2]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
1. Introduction
[MEF6] and [G.8011] provide parallel frameworks for defining network-
oriented characteristics of Ethernet services in transport networks.
The framework discusses general Ethernet connection characteristics,
Ethernet User Network Interfaces (UNIs), and Ethernet Network-Network
Interfaces (NNIs). Within this framework, [G.8011.1] defines the
Ethernet Private Line (EPL) service and [G.8011.2] defines the
Ethernet Virtual Private Line (EVPL) service. [MEF6] covers both
service types. [MEF10.1] defines service parameters and [MEF11]
provides UNI requirements and framework.
This document provides a method for GMPLS-based control of Label
Switched Paths (LSPs) that support the transport services defined in
the above documents at the UNI network reference points. This
document does not define or limit the underlying intra-domain or
Internal NNI (I-NNI) technology used to support the UNI. This
document makes use of the GMPLS extensions defined in [RFC6004] and
[RFC6002].
The scope of this document covers Ethernet UNI applications, and it
is intended to be consistent with the GMPLS overlay model presented
in [RFC4208] and aligned with GMPLS Core Network signaling. The
scope and reference model used in this document are represented in
Figure 1, which is based on Figure 1 of [RFC4208].
Figure 1 shows two core networks, each containing two core nodes.
The core nodes are labeled 'CN'. Connected to each CN is an edge
node. The edge nodes are labeled 'EN'. Each EN supports Ethernet
Networks and use Ethernet services provided by the core nodes via a
UNI. Two services are represented: one EPL and one EVPL type
service. Signaling within the core network is out of scope of this
document and may include any technology that supports overlay UNI
services. The UNI function in the edge node can be referred to as
the UNI client, or UNI-C, and in the CN as UNI network, or UNI-N.
Berger & Fedyk Standards Track [Page 3]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
Ethernet Ethernet
Network +----------+ +-----------+ Network
+---------+ | | | | +---------+
| +----+ | | +-----+ | | +-----+ | | +----+ |
------+ | | EPL | | | | | | | | EPL | | +------
------+ EN +-+-----+--+ CN +---------+ CN +--+-----+-+ EN +------
| | | | +--+--| +---+ | | +--+-----+-+ | |
| +----+ | | | +--+--+ | | | +--+--+ | | +----+ |
| | | | | | | | | | | |
+---------+ | | | | | | | | +---------+
| | | | | | | |
+---------+ | | | | | | | | +---------+
| | | | +--+--+ | | | +--+--+ | | |
| +----+ | | | | | | +-----+ | | | +----+ |
------+ +-+--+ | | CN +---------+ CN | | | | +------
------+ EN +-+-----+--+ | | | | +--+-----+-+ EN +------
| | | |EVPL | +-----+ | | +-----+ |EVPL | | | |
| +----+ | | | | | | +----+ |
| | +----------+ |-----------+ | |
+---------+ Core Network(s) +---------+
Ethernet UNI UNI Ethernet
Network <-----> <-----> Network
Scope of This Document
Legend: EN - Edge Node
CN - Core Node
Figure 1: Ethernet UNI Reference Model
1.1. Overview
This document uses a common approach to supporting the switching
implied by the Ethernet services defined in [MEF6], [G.8011.1], and
[G.8011.2]. The approach builds on standard GMPLS mechanisms to
deliver the required control capabilities. This document reuses the
GMPLS mechanisms specified in [RFC6004], [RFC4208], and [RFC4974].
Support for Point-to-Point (P2P) and Multipoint-to-Multipoint (MP2MP)
service is required by [G.8011] and [MEF11]. P2P service delivery
support is based on the GMPLS support for Ethernet services covered
in [RFC6004]. As with [RFC6004], the definition of support for MP2MP
service is left for future study and is not addressed in this
document.
[MEF11] defines multiple types of control for UNI Ethernet services.
In MEF UNI Type 1, services are configured manually. In MEF UNI Type
2, services may be configured manually or via a link management
interface. In MEF UNI Type 3, services may be established and
Berger & Fedyk Standards Track [Page 4]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
managed via a signaling interface. As with [RFC6004], this document
is aimed at supporting the MEF UNI Type 3 mode of operation (and not
MEF UNI Types 1 and 2). As mentioned above, this document is limited
to covering UNI-specific topics.
Common procedures used to signal Ethernet connections are described
in Section 2 of this document. Procedures related to signaling
switching in support of EPL services are described in Section 3.
Procedures related to signaling switching in support of EVPL services
are described in Section 4.
1.2. Conventions Used in This Document
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
2. Common Signaling Support
This section describes the common mechanisms for supporting a UNI
reference point for LSPs that provide the Ethernet Services described
in [RFC6004].
Except as specifically modified in this document, the procedures
related to the processing of Resource ReSerVation Protocol (RSVP)
objects is not modified by this document. The relevant procedures in
existing documents, notably [RFC6002], [RFC6004], [RFC4208], and
[RFC4974], MUST be followed in all cases not explicitly described in
this document.
2.1. UNI Addressing
LSPs providing Ethernet connections controlled via the mechanisms
defined in this document MUST use the addressing and other procedures
defined in [RFC4208]. Of note, this includes the use of the egress
edge node's IP address in the endpoint address field in the SESSION
object.
One issue that presents itself with the addressing approach taken in
[RFC4208] is that an ingress edge node may not receive the egress
edge node's IP address as part of the management, or other, request
that results in the initiation of a new Ethernet connection. This
case is covered as described in Section 7.2 of [RFC4974] and modified
below in Section 2.2.1.
Berger & Fedyk Standards Track [Page 5]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
2.2. Ethernet Endpoint (UNI) Identification
UNI identification, except as noted below, MUST follow Ethernet
endpoint (UNI) identification as defined in [RFC6004]. There is one
additional case that is covered in this document where the scope of
the Ethernet endpoint identifier is relevant beyond the typical case
of just ingress and egress nodes.
2.2.1. Address Resolution
At the UNI reference point, it is possible for the ingress edge node
to not have the egress edge node's IP address when initiating an LSP.
This presents an issue as the egress edge node's IP address is
carried in the SESSION object. This case is handled leveraging the
approach described in Section 7.2 of [RFC4974] to address call ID
assignment by the first core node.
When an edge node (the UNI-C) initiates an LSP and it has the egress
Ethernet endpoint identifier, but does not have its IP address, the
edge node MUST create a Notify message as described in [RFC4974].
The Notify message MUST include the CALL_ATTRIBUTES object with the
Endpoint ID TLV defined [RFC6004]. The tunnel endpoint address field
of the SESSION object in the Notify message MUST be set to zero (0).
The message MUST be addressed and sent to an address associated with
the first core node.
When a core node, i.e., the node providing the network side of the
UNI (the UNI-N), receives a Notify message with the tunnel endpoint
address field of the SESSION object set to zero, it MUST locate the
Endpoint ID TLV in the CALL_ATTRIBUTES object. If the object or TLV
are not present, the node MUST discard the message. In this case, a
Message ID Acknowledgment MUST NOT be sent for the Notify message.
When the Endpoint ID TLV is located, the node MUST map the Endpoint
ID into an IP address associated with the egress edge node. If the
node is unable to obtain an egress address, it MUST issue an error
response Notify messages according to Section 6.2.2. of [RFC4974].
The Error code and value SHOULD be "Routing Problem/Unknown Endpoint"
(Error code 24, Error value 35).
When the node is able to obtain an egress address, the endpoint
address field of the SESSION object MUST be set to the obtained
address, and the Notify message should be sent according to the
standard processing defined in [RFC4974]. The downstream nodes will
then process the Notify according to standard processing rules.
Berger & Fedyk Standards Track [Page 6]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
When the ingress receives the response Notify message, it SHOULD
identify the call based on the Endpoint ID TLV and, when not set to
zero on the corresponding setup Notify message, the short and long
Call IDs. The endpoint address field of the SESSION object carried
in the response Notify message will include the egress's IP address.
This returned address MUST be used in all subsequent messages
associated with the Ethernet connection.
Note that the procedure described in this section MAY be used when
the Call IDs are generated by the initiating UNI or generated by the
first core node.
2.3. Connection Identification
With one exception, UNI signaling for Ethernet connections MUST
follow the Connection Identification procedures defined in [RFC6004].
The exception is that the procedures defined in Section 7.2 of
[RFC4974] MAY be used to provide support for allocation of Call IDs
by the first core node rather than by the initiating edge node.
3. EPL Service
There are no additional UNI-specific requirements for signaling LSPs
supporting Ethernet Private Line (EPL) services. The procedures
defined in [RFC6004], as modified above, MUST be followed when
signaling an LSPs supporting an EPL Service.
4. EVPL Service
There is one additional UNI-specific requirement for signaling LSPs
supporting an EVPL type service as described in Section 4.1. Except
as modified above and by this section, the procedures defined in
[RFC6004] MUST be followed when signaling an EVPL Service.
4.1. Egress VLAN ID Control and VLAN ID Preservation
Per [MEF6], the mapping of the single VLAN ID used at the ingress UNI
to a different VLAN ID at the egress UNI is allowed for EVPL services
that do not support both bundling and VLAN ID preservation. Such a
mapping MUST be requested and signaled based on the explicit label
control mechanism defined in [RFC4208], and not the mechanisms
defined in [RFC6004].
As is the case in [RFC6004], when the explicit label control
mechanism is not used VLAN IDs MUST be preserved, i.e., not modified,
across the LSP.
Berger & Fedyk Standards Track [Page 7]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
5. IANA Considerations
IANA has assigned new values for namespaces defined in this document
and summarized in this section.
5.1. Error Value: Routing Problem/Unknown Endpoint
IANA has made the following assignment in the "Error Codes and
Globally-Defined Error Value Sub-Codes" section of the "RSVP
Parameters" registry located at http://www.iana.org:
Error Code Meaning
24 Routing Problem [RFC3209]
Under "This Error Code has the following globally-defined Error
Value sub-codes:"
35 = Unknown Endpoint [RFC6005]
6. Security Considerations
This document makes use of the mechanisms defined in [RFC6004] and
[RFC4974]. It does not in itself change the security models offered
in each. (Note that the address resolution discussed in Section 2.2
above, parallels the replacement of information that occurs per
Section 7.2 of [RFC4974].) See [RFC6004] and [RFC4974] for the
security considerations that are relevant to and introduced by the
base mechanisms used by this document.
7. References
7.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC3209] Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V.,
and G. Swallow, "RSVP-TE: Extensions to RSVP for LSP
Tunnels", RFC 3209, December 2001.
[RFC4208] Swallow, G., Drake, J., Ishimatsu, H., and Y. Rekhter,
"Generalized Multiprotocol Label Switching (GMPLS) User-
Network Interface (UNI): Resource ReserVation Protocol-
Traffic Engineering (RSVP-TE) Support for the Overlay
Model", RFC 4208, October 2005.
Berger & Fedyk Standards Track [Page 8]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
[RFC4974] Papadimitriou, D. and A. Farrel, "Generalized MPLS (GMPLS)
RSVP-TE Signaling Extensions in Support of Calls", RFC
4974, August 2007.
[RFC6002] Berger, L. and D. Fedyk, "Generalized MPLS (GMPLS) Data
Channel Switching Capable (DCSC) and Channel Set Label
Extensions", RFC 6002, October 2010.
[RFC6004] Berger, L. and D. Fedyk, "Generalized MPLS (GMPLS) Support
for Metro Ethernet Forum and G.8011 Ethernet Service
Switching", RFC 6004, October 2010.
7.2. Informative References
[G.8011] ITU-T G.8011/Y.1307, "Ethernet over Transport Ethernet
services framework", August 2004.
[G.8011.1] ITU-T G.G.8011.1/Y.1307.1, "Ethernet private line
service", August 2004.
[G.8011.2] ITU-T G.8011.2/Y.1307.2, "Ethernet virtual private line
service", September 2005.
[MEF6] The Metro Ethernet Forum, "Ethernet Services Definitions -
Phase I", MEF 6, June 2004.
[MEF10.1] The Metro Ethernet Forum, "Ethernet Services Attributes
Phase 2", MEF 10.1, November 2006.
[MEF11] The Metro Ethernet Forum , "User Network Interface (UNI)
Requirements and Framework", MEF 11, November 2004.
Acknowledgments
Dimitri Papadimitriou provided substantial textual contributions to
this document and coauthored earlier versions of this document.
The authors would like to thank Evelyne Roch and Stephen Shew for
their valuable comments.
Berger & Fedyk Standards Track [Page 9]
^L
RFC 6005 GMPLS Support for MEF and G.8011 UNI October 2010
Authors' Addresses
Lou Berger
LabN Consulting, L.L.C.
Phone: +1-301-468-9228
EMail: lberger@labn.net
Don Fedyk
Alcatel-Lucent
Groton, MA 01450
Phone: +1-978-467-5645
EMail: donald.fedyk@alcatel-lucent.com
Berger & Fedyk Standards Track [Page 10]
^L
|