1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
|
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Telnet Data Entry Terminal Option
1. Command Name and code:
DET 20
2. Command Meanings
IAC WILL DET
The sender of this command REQUESTS or AGREES to send and
receive subcommands to control the Data Entry Terminal.
IAC WONT DET
The sender of this command REFUSES to send and receive
subcommands to control the Data Entry Terminal.
IAC DO DET
The sender of this command REQUESTS or AGREES to send and
receive subcommands to control the Data Entry Terminal.
IAC DONT DET
The sender of this command REFUSES to send and receive
subcommands to control the Data Entry Terminal.
The DET option uses five classes of subcommands 1) to
establish the requirements and capabilities of the
application and the terminal, 2) to format the screen, and
to control the 3) edit, 4) erasure, and 5) transmission
functions. The subcommands that perform these functions are
described below.
T__h_e_N__e_t_w_o_r_k_V__i_r_t_u_a_l_D__a_t_a_E__n_t_r_y_T__e_r_m_i_n_a_l(NVDET)
The NVDET consists of a keyboard and a rectangular
display. The keyboard is capable of generating all of
the characters of the ASCII character set. In addition,
the keyboard may possess a number of function keys which
when pressed cause a FN subcommand to be sent. (Although
most DET's will support one or more peripheral devices
such as a paper tape reader or a printer, this option
1
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
does not consider their support. Support of peripheral
devices should be treated by a separate option.)
The screen of the data entry terminal is a rectangle M
characters by N lines. The values of M and N are set by
negotiating the Output Line Width and Output Page Size
options, respectively. The next writing position (x,y)
on the screen (where x is the character position and y is
the position of the line on the screen) is indicated by a
special display character called the cursor. The cursor
may be moved to any position on the screen without
disturbing any characters already on the screen. Cursor
addressing in existing terminals utilizes several
topologies and addressing methods. In order to make the
burden of implementaton as easy as possible this protocol
supports two topologies (the finite plane and the helical
torus) and three addressing methods ((x,y); x and y, and
relative increments). Since the finite plane with
absolute addressing is the least ambiguous and the
easiest to translate to and from the others, it is the
default scheme used by the NVDET. The torodial form with
either relative or absolute addressing is provided for
convience.
Also the NVDET provides a mechanism for defining on the
screen fields with special attributes. For example,
characters entered into these fields may be displayed
with brighter intensity, highlighted by reverse video or
blinking, or protected from modification by the user.
This latter feature is one of the most heavily used for
applications where the DET displays a form to be filled
out by the user.
The definition of the NVDET uses Telnet option
subnegotiations to accomplish all of its functions.
Since none of the ASCII characters sent in the data
stream have been used to define these functions, the DET
option can be used in a "raw" or even "rare" mode. In
circumstances where the application program knows what
kind of terminal is on the other end, it can send the
ASCII characters required to control functions not
supported by the option or an implementation. In general
keeping all NVDET functions out of the data stream
provides better flexibility.
F__a_c_i_l_i_t_y_F__u_n_c_t_i_o_n_s (for detailed semantics see Section 5.)
IAC SB DET <DET facility subcommand><facility map> IAC SE
where <DET facility subcommand> is one 8-bit byte
2
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
indicating the class of the facilities to be described,
and <facility map> is a field of one or two 8-bit bytes
containing flags describing the facilities required or
desired by the sender. The bits of the facility maps are
numbered from the right starting at zero. Thus, if bit 2
is set the field will have a decimal value of 4. The
values of the field are as follows:
facility cmd: EDIT FACILITIES subcommand code: 1
facility map: bit numbers
Toroidal Cursor Addressing 6
Incremental Cursor Addressing 5
Read Cursor Address 4
Line Insert/Delete 3
Char Insert/Delete 2
Back Tab 1
Positive Addressing only 0
where:
If the Toroidal Cursor Addressing bit is set, the sender
requests or provides that the SKIP TO LINE and SKIP TO
CHAR subcommands be supported.
If the Incremental Cursor Addressing bit is set, the
sender requests or provides that the UP, DOWN, LEFT, and
RIGHT subcommands be supported.
If the Read Cursor bit is set, the sender requests or
provides the READ CURSOR subcommand.
If the Line Insert/Delete bit is set, the sender requests
or provides that the LINE INSERT and LINE DELETE
subcommands be supported.
If the Char Insert/Delete bit is set, the sender requests
or provides that the CHAR INSERT and CHAR DELETE
subcommands be supported.
If the Back Tab bit is set, the sender requests or
provides that the BACK TAB subcommand be supported.
If the Positive Addressing bit is set, then the sender is
informing the receiver that it can only move the cursor
in the positive direction. (Note: Terminals that have
this property also have a Home function to get back to
the beginning.)
facility cmd: ERASE FACILITIES subcommand code: 2
facility map: bit numbers
3
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Erase Field 4
Erase Line 3
Erase Rest of Screen 2
Erase Rest of Line 1
Erase Rest of Field 0
where:
If a bit of the facility map for this facility command is
set, the sender requests or provides the facility
indicated by the bit. For a more complete description of
each of these functions see the Erase Functions section
below.
facility cmd: TRANSMIT FACILITIES subcommand code: 3
facility map: bit numbers
Data Transmit 5
Transmit Line 4
Transmit Field 3
Transmit Rest of Screen 2
Transmit Rest of Line 1
Transmit Rest of Field 0
where:
If a bit of the facility map for this facility command is
set, the sender requests or provides the facility
indicated by the bit. For a more complete description of
each of these functions see the Transmit Functions
section below.
facility cmd: FORMAT FACILITIES subcommand code: 4
facility map: bit numbers
byte 0
Repeat 4
Blinking 3
Reverse Video 2
Right Justification 1
Overstrike 0
byte 1
Protection On/Off 6
Protection 5
Alphabetic-only Protection 4
Numeric-only Protection 3
Intensity 0-2
where:
If the Repeat bit is set the sender requests or provides
4
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
the REPEAT subcommand.
If the Blinking bit is set, the sender requests or
provides the ability to highlight a string of characters
by causing them to blink.
If the Reverse Video bit is set, the sender requests or
provides the ability to highlight a string of characters
by "reversing the video image," i.e., if the characters
are normally displayed as black characters on a white
background, this is reversed to be white characters on a
black background, or vice versa.
If the Right Justification bit is set, the sender
requests or provides the ability to cause entries of data
to be right justified in the field.
If the Overstrike bit is set, the sender requests or
provides the ability to superimpose one character over
another on the screen much like a hard copy terminal
would do if the print mechanism struck the same position
on the paper with different characters.
If the Protection On/Off bit is set, the sender requests
or provides the ability to turn on and off field
protection.
If the Protection bit is set, the sender requests or
provides the ability to protect certain strings of
characters displayed on the screen from being altered by
the user of the terminal. Setting this bit also implies
that ERASE UNPROTECTED and TRANSMIT UNPROTECTED
subcommands (see below) are supported.
If the Alphabetic-only Protection bit is set, the sender
requests or provides the ability to constrain the user of
the terminal such that he may only enter alphabetic data
into certain areas of the screen.
If the Numeric-only Protection bit is set, the sender
requests or provides the ability to constrain the user of
the terminal such that he may only enter numerical data
into certain areas of the screen.
The three bits of the Intensity field will contain a
positive binary integer indicating the number of levels
of intensity that the sender requests or provides for
displaying the data. The value of the 3 bit field should
be interpreted in the following way:
5
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
1 one visible intensity
2 two intensities; normal and bright
3 three intensities; off, normal, and bright
>3 >3 intensities; off, and the remaining levels
proportioned from dimmest to brightest intensity.
For the all of the above commands, if the appropriate bit
in <facility map> is not set, then the sender does not
request or provide that facility.
E__d_i_t_i_n_g_F__u_n_c_t_i_o_n_s
IAC SB DET MOVE CURSOR <x><y> IAC SE subcommand code: 5
where <x> is an 8-bit byte containing a positive binary
integer representing the character position of the
cursor, <y> is an 8-bit byte containing a positive binary
integer representing the line position of the cursor.
This subcommand moves the cursor to the absolute screen
address (x,y) with the following boundary conditions:
if x>M-1, set x=M-1 and send an ERROR subcommand
if y>N-1, set y=N-1 and send an ERROR subcommand
This describes a finite plane topology on the screen.
IAC SB DET SKIP TO LINE <y> IAC SE subcommand code: 6
where <y> is a positive 8-bit binary number.
This subcommand moves the cursor to the absolute screen
line y. x remains constant. For values of y>N-1
y = y mod N.
IAC SB DET SKIP TO CHAR <x> IAC SE subcommand code: 7
where <x> is a positive 8-bit binary number.
This subcommand moves the cursor to the absolute
character position x. y remains constant, unless x>M-1
in which case:
x' = (x mod M)
y' = (y+(x DIV N))
where x' and y' are the new values of the cursor.
These last two subcommands define a toroidal topology on
the screen.
6
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
IAC SB DET UP IAC SE subcommand code: 8
IAC SB DET DOWN IAC SE subcommand code: 9
IAC SB DET LEFT IAC SE subcommand code: 10
IAC SB DET RIGHT IAC SE subcommand code: 11
These subcommands are provided as a convenience for some
terminals. The commands UP, DOWN, LEFT, and RIGHT are
defined as
UP: (x,y)=(x, y-1 mod N)
DOWN: (x,y)=(x, y+1 mod N)
LEFT: (x,y)=(x-1, y); if x=0 then x-1 = 0
RIGHT: (x,y)=(x+1 mod M, y) and y = y+1 if x+1>M-1
Note: DOWN, LEFT, and RIGHT cannot always be replaced by
the ASCII codes for linefeed, backspace, and space
respectively. The latter are format effectors while the
former are cursor controls.
IAC SB DET HOME IAC SE subcommand code: 12
This subcommand positions the cursor to (0,0). This is
equivalent to a MOVE CURSOR 0,0 or the sequence SKIP TO
LINE 0, SKIP TO CHAR 0. This subcommand is provided for
convenience, since most terminals have it as a separate
control.
IAC SB DET LINE INSERT IAC SE subcommand code: 13
This subcommand inserts a line of spaces between lines y
(the current line, determined by the position of the
cursor) and line y-1. Lines y through N-2 move down one
line, i.e. line y becomes line y+1; y+1 becomes y+2,
...; N-2 becomes N-1. Line N-1 is lost off the bottom of
the screen. The position of the cursor remains
unchanged.
IAC SB DET LINE DELETE IAC SE subcommand code: 14
This subcommand deletes line y where y is the current
line position of the cursor. Lines y+1 through N-1 move
up one line, i.e. line y+1 becomes line y; y+2 becomes
y+1; ...; N-1 becomes N-2. The N-1st line position is
set to all spaces. The cursor position remains
unchanged.
IAC SB DET CHAR INSERT IAC SE subcommand code: 15
This subcommand inserts the next character in the data
stream between the xth and x-1st characters, where x is
7
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
the current character position of the cursor. The xth
through M-2nd characters on the line are shifted one
character positon to the right. The new character is
inserted at the vacated xth position. The M-1st
character is lost. The position of the cursor remains
unchanged.
IAC SB DET CHAR DELETE IAC SE subcommand code: 16
This subcommand deletes the character on the screen at
the x-th position. The x-th character is removed and the
characters x+1 through M-1 are shifted one character
position to the left to become the x-th through M-2nd
characters. The M-1st character position is left empty.
(For most terminals it will be set to a NUL or space.)
The cursor position remains unchanged.
IAC SB DET READ CURSOR IAC SE subcommand code: 17
This subcommand requests the receiver to send the present
position of the cursor to the sender.
IAC SB DET CURSOR POSITION <x><y> IAC SE
subcommand code: 18
where <x> and <y> are positive 8-bit binary integers.
This subcommand is sent by a Telnet implementation in
response to a READ CURSOR subcommand to convey the
coordinates of the cursor to the other side. Note: x is
less than M and y is less than N.
IAC SB DET REVERSE TAB IAC SE subcommand code: 19
This subcommand causes the cursor to move to the previous
tab position. If none exists on the present line, the
cursor moves to the previous line and so on until a tab
is found or the address (0,0) is encountered. When field
protection is in effect the cursor moves to the beginning
of the preceding unprotected field.
T__r_a_n_s_m_i_t_F__u_n_c_t_i_o_n_s (For detailed semantics see Section 5.)
IAC SB DET TRANSMIT SCREEN IAC SE subcommand code: 20
This subcommand causes the terminal to transmit all
characters on the screen from position (0,0) to
(M-1,N-1). The cursor will be at (0,0) after the
operation is complete.
8
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
IAC SB DET TRANSMIT UNPROTECTED IAC SE
subcommand code: 21
This subcommand causes the terminal to transmit all
characters in unprotected fields from position (0,0) to
(M-1,N-1). The unprotected fields are separated by the
field separator subcommand. The cursor will be at (0,0)
or at the beginning of the first unprotected field after
the operation is complete.
IAC SB DET TRANSMIT LINE IAC SE subcommand code: 22
This subcommand causes the terminal to transmit all data
on the yth line where y is determined by the present
position of the cursor. Data is sent from character
position (0,y) to the end-of-line or position (M-1,y)
whichever comes first. The cursor position after the
transmission is one character position after the end of
line condition or the beginning of the next line,
(0,y+1).
IAC SB DET TRANSMIT FIELD IAC SE subcommand code: 23
This subcommand causes the terminal to transmit all data
in the field presently occupied by the cursor. The
cursor position after the operation is complete is one
character position after the end of the field or, if that
position is protected, at the beginning of the next
unprotected field.
IAC SB DET TRANSMIT REST OF SCREEN IAC SE
subcommand code: 24
This subcommand causes the terminal to transmit all
characters on the screen from position (x,y) to (M-1,N-1)
or until the end of text. (x,y) is the current cursor
position. The cursor position after the operation is one
character position after the last text character, or
(0,0) if the last filled character position is (M-1,N-1).
IAC SB DET TRANSMIT REST OF LINE IAC SE
subcommand code: 25
This subcommand causes the terminal to transmit all
characters on the yth line from position (x,y) to the end
of line or (M-1,y) whichever comes first. (x,y) is the
current cursor position. The cursor position after the
operation is one character position after the last
character of the line or the first character of the next
line.
9
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
IAC SB DET TRANSMIT REST OF FIELD IAC SE
subcommand code: 26
This subcommand causes the receiver to transmit the rest
of the characters in the field currently occupied by the
cursor. The cursor position after the operation is at
the beginning of the next field.
IAC SB DET DATA TRANSMIT <x><y> IAC SE
subcommand code: 27
This subcommand is used to preface data sent from the
terminal in response to a user action or a TRANSMIT
command. The parameters <x> and <y> indicate the initial
position of the cursor. See the Transmit Subcommands
subsection in Section 5 for more details.
E__r_a_s_e_F__u_n_c_t_i_o_n_s
IAC SB DET ERASE SCREEN IAC SE subcommand code: 28
This subcommand causes all characters to be removed from
the screen. All fields regardless of their attributes
are deleted. The cursor position after the operation
will be (0,0). Most terminals set the erased characters
to either NUL or space characters.
IAC SB DET ERASE LINE IAC SE subcommand code: 29
This subcommand causes all characters on the yth line to
be removed from the screen, where y is the line of the
current cursor position. All fields regardless of their
attributes are deleted. The cursor position after this
operation will be (0,y). Note: This operation can be
easily simulated by the sequence: LINE DELETE, LINE
INSERT. However, the order is important to insure that
no data is lost off the bottom of the screen.
IAC SB DET ERASE FIELD IAC SE subcommand code: 30
This subcommand causes all characters in the field
occupied by the cursor to be removed. The cursor
position after the operation is at the beginning of the
field.
IAC SB DET ERASE REST OF SCREEN IAC SE
subcommand code: 31
10
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
This subcommand causes all characters from position (x,y)
to (M-1,N-1) to be removed from the screen. All fields
regardless of their attributes are deleted. The cursor
position after the operation is unchanged. This is
equivalent to doing an ERASE REST OF LINE plus a LINE
DELETE for lines greater than y.
IAC SB DET ERASE REST OF LINE IAC SE
subcommand code: 32
This subcommand causes all characters from position (x,y)
to (M-1,y) to be removed from the screen All fields
regardless of their attributes are deleted. The cursor
position after the operation is unchanged.
IAC SB DET ERASE REST OF FIELD IAC SE
subcommand code: 33
This subcommand causes all characters from position (x,y)
to the end of the current field to be removed from the
screen. The cursor position after the operation is
unchanged.
IAC SB DET ERASE UNPROTECTED IAC SE
subcommand code: 34
This subcommand causes all characters on the screen in
unprotected fields to be removed from the screen. The
cursor position after the operation is at (0,0) or, if
that position is protected, at the beginning of the first
unprotected field.
F__o_r_m_a_t_F__u_n_c_t_i_o_n_s
IAC SB DET FORMAT DATA <format map><count> IAC SE
subcommand code: 35
where <format map> is an 8-bit byte containing the
following flags:
Blinking 7
Reverse Video 6
Right Justification 5
Protection 3-4
Intensity 0-2
where:
If the Blinking bit is set, the following field of
<count> characters should have the Blinking attribute
11
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
applied to it by the receiver.
If the Reverse Video bit is set, the following field of
<count> characters should be displayed by the receiver
with video reversed.
If the Right Justification bit is set, the input entered
into the field of <count> characters should be right
justified.
The Protection field is two bits wide and may take on the
following values:
0 no protection
1 protected
2 alphabetic only
3 numeric only
The protection attribute specifies that the other side
may modify any character (no protection), modify no
characters (protected), enter only alphabetical
characters (A-Z, and a-z) (alphabetic only), or enter
only numerical characters (0-9,+,.,and -) (numeric only)
in the following field of <count> bytes.
The Intensity field is 3 bits wide and should be
interpreted in the following way:
The values 0-6 should be used as an indication of the
relative brightness to be used when displaying the
characters in or entered into the following field <count>
characters wide. The number of levels of brightness
available should have been obtained previously by the
Format Facility subcommand. The exact algorithm for
mapping these values to the available levels of intensity
is left to the implementors. A value of 7 in the
intensity field indicates that the brightness should be
off, and any characters in or entered into the field
should not be displayed.
<count> is 2 bytes that should be interpreted as a
positive 16-bit binary integer representing the number of
characters following this command which are affected by
it.
Data sent to the terminal or the Using Host for unwritten
areas of the screen not in the scope of the count should
be displayed with the default values of the format map.
The default values are No Blinking, Normal Video, No
Justification, No Protection and Normal Intensity.
12
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
This subcommand is used to format data to be displayed on
the screen of the terminal. The <format map> describes
the attributes that the field <count> bytes wide should
have. This field is to start at the position of the
cursor when the command is acted upon. The next <count>
displayable characters in the data stream are used to
fill the field. Subsequent REPEAT subcommands may be
used to specify the contents of this field. If the
sender specifies attributes that have not been agreed
upon by the use of the Format Facility subcommand, the
Telnet process should send an Error Subcommand to the
sender, but format the screen as if the bit had not been
set.
IAC SB DET REPEAT <count><char> IAC SE
subcommand code: 36
where <count> is a positive 8-bit binary integer.
<char> is an 8-bit byte containing an ASCII character.
This subcommand is used to perform data compression on
data being transferred to the terminal by encoding
strings of identical characters as the character and a
count. The repeated characters may be part of a field
specified
IAC SB DET SUPPRESS PROTECTION <negotiation> IAC SE
subcommand code: 37
where <negotiation> may have the values of the Telnet
option negotiation:
251 WILL
252 WONT
253 DO
254 DONT
This subcommand is used to suppress the field protection
in a non-destructive manner. Many data entry terminals
provide the means by which protection may be turned on
and off without modifying the contents of the screen or
the terminal's memory. Thus, the protection may be
turned off and back on without retransmitting the form.
The default setting of the option is that protection is
on, in other words
IAC SB DET SUPPRESS PROTECTION WONT IAC SE
IAC SB DET SUPPRESS PROTECTION DONT IAC SE
13
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Negotiation of this subcommand follows the same rules as
negotiations of the Telnet options.
IAC SB DET FIELD SEPARATOR IAC SE subcommand code: 38
It is necessary when transmitting only the unprotected
portion of the screen to provide a means for delimiting
the fields. Existing DET's use a variety of ASCII
characters such as Tab, Group Separator, Unit Separator,
etc. In order to maintain transparency of the NVDET this
subcommand is used to separate the fields. Clearly, this
incurs rather high overhead. This overhead can be
avoided by using the Byte Macro Option (see Appendix 3).
M__i_s_c_e_l_l_a_n_e_o_u_s_C__o_m_m_a_n_d_s
IAC SB DET FN <code> IAC SE subcommand code: 39
where: <code> is one byte.
Many data-entry terminals provide a set of "function"
keys which when pressed send a one-character command to
the server. This subcommand describes such a facility.
The values of the <code> field are defined by the user
and server. The option merely provides the means to
transfer the information.
IAC SB DET ERROR <cmd> <error code> IAC SE
subcommand code: 40
where:
<cmd> is a byte containing the subcommand code of
the subcommand in error.
<error code> is a byte containing an error code.
(For a list of the defined error codes see Appendix 2.)
This subcommand is provided to allow DET option
implementations to report errors they detect to the
corresponding Telnet process. At this point it is worth
reiterating that the philosophy of this option is that
when an error is detected it should be reported; however,
the implementation should attempt its best effort to
carry out the intent of the subcommand or data in error.
14
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
3. Default and Minimal Implementation Specifications
D__e_f_a_u_l_t
WON'T DET -- DON'T DET
Neither host wishes to use the Data Entry Terminal option.
M__i_n_i_m_a_l_I__m_p_l_e_m_e_n_t_a_t_i_o_n
DET EDIT FACILITIES
DET ERASE FACILITIES
DET TRANSMIT FACILITIES
DET FORMAT FACILITIES
DET MOVE CURSOR <x><y>
DET HOME
DET ERASE SCREEN
DET TRANSMIT SCREEN
DET FORMAT DATA
DET ERROR <cmd> <error code>
In the case of formatting the data, the minimal
implementation should be able to support a low and high
level of intensity and protection for all or no
characters in a field. These functions, however, are not
required.
The minimal implementation also requires that the Output
Line Width and Output Page Size Telnet options be
supported.
15
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
4. Motivation
The Telnet protocol was originally designed to provide a
means for scroll-mode terminals, such as the standard
teletype, to communicate with processes through the network.
This was suitable for the vast majority of terminals and
users at that time. However, as use of the network has
increased into other areas, especially areas where the
network is considered to provide a production environment
for other work, the desires and requirements of the user
community have changed. Therefore, it is necessary to
consider supporting facilities that were not initially
supported. This Telnet option attempts to do that for
applications that require data entry terminals.
This option in effect defines the Network Virtual Data Entry
Terminal. Although the description of this option is quite
long, this does not imply that the Telnet protocol is a poor
vehicle for this facility. Data Entry Terminals are rather
complex and varied in their abilities. This option attempts
to support both the minimal set of useful functions that are
either common to all or can be easily simulated and the more
sophisticated functions supplied in some terminals.
Unlike most real data entry terminals where the terminal
functions are encoded into one or more characters of the
native character set, this option performs all such controls
within the Telnet subnegotiation mechanism. This allows
programs that are intimately familiar with the kind of
terminal they are communicating with to send commands that
may not be supported by either the option or the
implementation. In other words, it is possible to operate
in a "raw" or at least "rare" mode using as much of the
option as necessary.
Although many data entry terminals support a variety of
peripheral devices such as printers, cassettes, etc. it is
beyond the scope of this option to entertain such
considerations. A separate option should be defined to
handle this aspect of these devices.
16
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
5. Description
G__e_n_e_r_a_l_N__o_t_e_s
All implementations of this option are required to support a
certain minimal set of the subcommands for this option.
Section 3 contains a complete list of the subcommands in
this minimal set. In keeping with the Telnet protocol
philosophy that an implementation should not have to be able
to parse commands it does not implement, every subcommand of
this option is either in the minimal set or is covered by
one of the facility subcommands. An implementation must
"negotiate" with its correspondent for permission to use
subcommands not in the minimal set before using them. For
details of this negotiation process see the section below on
facility subcommands.
Most data entry terminals are used in a half duplex mode.
(Although most DET's on the market can be used either as
data entry terminals or as standard interactive terminals,
we are only concerned here with their use as DET's.) When
this option is used, it is suggested that the following
Telnet options be refused: Echo, Remote Controlled
Transmission and Echoing, and Suppress Go-Ahead. However,
this option could be used to support a simple full duplex
CRT based application using the basic cursor control
functions provided here. For these cases, one or more of
the above list of options might be required. (Support of
sophisticated interactive calligraphic applications is
beyond the scope of this option and should be done by
another option or the Network Graphics Protocol.)
In RFC 728, it was noted that a synch sequence can cause
undesired interactions between Telnet Control functions and
the data stream. A synch sequence causes data but not
control functions to be flushed. If a control function
which has an effect on the data immediately following it is
present in the data stream when a synch sequence occurs, the
control function will have its effect not on the intended
data but on the data immediately following the Data Mark.
The following DET subcommands are susceptible to this
pitfall:
CHAR INSERT
DATA TRANSMIT
FORMAT DATA
The undesired interactions are best avoided by the receiver
17
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
of the synch sequence deleting these subcommands and all
data associated with them before continuing to process the
control functions. This implies that the Data Mark should
not occur in the middle of the data associated with these
subcommands.
F__a_c_i_l_i_t_y_S__u_b_c_o_m_m_a_n_d_s
These four subcommands are used by the User and Server
implementations to negotiate the subcommands and attributes
of the terminal that may be utilized. This negotiation can
be viewed as the terminal (User Host) indicating what
facilities are provided and the Server Host (or application
program) indicating what facilities are desired.
W__h_e_n_S__e_n_t:_ A Server Telnet implementation using the DET
option must send a facility subcommand requesting the use of
a particular subcommand or terminal attribute not in the
minimal implementation before the first use of that
subcommand or attribute. The User Telnet implementation
should respond as quickly as possible with its reply.
Neither the User nor Server are required to negotiate one
subcommand at a time. Also, a Telnet implementation
responding to a facility subcommand is not required to give
permission only for that subcommand. It may send a format
map indicating all facilities of that class which it
supports. However, a Telnet implementation requesting
facilities must send a facility subcommand before its first
use of the subcommand regardless of whether earlier
negotiations have indicated the facility is provided. The
facility cannot be used until a corresponding facility
subcommand has been received. There are no other
constraints on when the facility subcommands may be sent.
In particular, it is not necessary for an application to
know at the beginning of a session all facilities that it
will use.
A__c_t_i_o_n_W__h_e_n_R__e_c_i_e_v_e_d:_ There are two possible actions that
may be taken when a facility subcommand is received
depending on whether the receiver is a requestor or a
provider (User).
Requestor: When a facility subcommand is received by a
requestor and it is in the state of Waiting for a Reply, it
should go into the state of Not Waiting. It should then
take the facility map it had sent and form the logical
intersection with the facility map received. (For the
Intensity attribute, one should take the minimum of the
number received and the number requested.) The result
indicates the facilities successfully negotiated. Note: if
18
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
the receiver is not in the Waiting for Reply state, then
this is the provider case described next.
Provider: When a facility subcommand is received, it
should send a facility subcommand with a facility map of the
facilities it provides as soon as possible. It should then
determine what new facilities it is providing for the
Requestor by forming the logical intersection of the
facility map received and the one sent.
Note: Although in most cases the requestor will be the
Server Host and the provider will be the User Host
supporting the terminal, this distinction may not always be
true.
T__r_a_n_s_m_i_t_S__u_b_c_o_m_m_a_n_d_s
There are two kinds of transmit subcommands: those used to
request that data be sent to the requestor, and one to
preface data sent to the requestor. The first kind allow
the requestor to control when, from where and to some degree
how much data is transmitted from the terminal. Their
explanation is straightforward and may be found in Section
2.
Data may be sent from the terminal as a result of two
events: the user of the terminal caused the transmission or
in response to a transmit subcommand. Some programs may
wish to know from where on the screen the transmission
began. (This is reasonable, since the terminal user may
move the cursor around considerably before transmitting.)
Other programs may not need such information. The DATA
TRANSMIT subcommand is provided in case this function is
needed. When used this subcommand prefaces data coming from
the terminal. The parameters <x> and <y> give the screen
coordinates of the beginning of the transmission. <x> must
be less than or equal to M-1 and <y> must be less than or
equal to N-1. It is assumed that all data between this DATA
TRANSMIT and the next one starts at the coordinates given
by the first subcommand and continues filling each line
thereafter according to the constraints of the screen and
the format effectors in the data. Thus an intelligent or
sloppy user-host DET implementation (depending on your point
of view) need only include a DATA TRANSMIT subcommand when
the new starting point is different from the last ending
point.
6. Sample Interaction
19
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
The nomenclature of RFC 726 will be used to describe this example. To
quote that RFC:
"S:" is sent from serving host to using host.
"U:" is sent from using host to serving host.
"T:" is entered by the terminal user.
"P:" is printed on the terminal.
Text surrounded by square brackets([]) is commentary. Text
surrounded by angle brackets (<>) is to be taken as a single unit.
E.g, carriage return is <cr>, and the decimal value 27 is
represented <27>.
We assume that the user has established the Telnet connection,
logged on, and an application program has just been started either
by the user directly or through a canned start up procedure. The
presentation on the page is meant to merely group entities together
and does not imply the position of message boundaries. One should
assume that any part of the dialogue may be sent as one or many
messages. The first action of the program or Telnet is to
negotiate the DET option:
S: <IAC><DO><DET>
U: <IAC><WILL><DET>
S:<IAC><DO><OUTPUT PAGE SIZE> [First negotiate the screen
size. In this case we are
U:<IAC><WILL><NAOP> asking the user the size of the
terminal. This could have been
U:<IAC><SB><NAOP><DR><25><IAC><SE> done before the DET option was
negotiated.]
S:<IAC><SB><NAOP><DS><0><IAC><SE>
S:<IAC><DO><OUTPUT LINE WIDTH>
U:<IAC><SB><NAOL><DR><80><IAC><SE> [Defines the screen to be 25
lines by 80 characters.
S:<IAC><SB><NAOL><DS><0><IAC><SE> The server may use this
information when formatting
the screen.]
S:<IAC><SB><DET><FORMAT FACILITIES> [Now set the terminal attributes.]
<Repeat><Protection, 3 Levels
Intensity><IAC><SE>
U:<IAC><SB><DET><FORMAT FACILITIES>
<Repeat, Blinking><Protection, 3
Levels Intensity><IAC><SE>
S:<IAC><SB><DET><ERASE SCREEN><IAC><SE> [Erase the screen and
20
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
start sending the form.]
<IAC><SB><DET><FORMAT DATA>
<Protection=1, Intensity=1><0>
<5><IAC><SE>Name:
<IAC><SB><DET><MOVE CURSOR><0><1>
<IAC><SE>
<IAC><SB><DET><FORMAT DATA>
Protection=1, Intensity=1><0>
<8><IAC><SE>
Address:
<IAC><SB><MOVE CURSOR><0><4><IAC>
<SE>
<IAC><SB><DET><FORMAT DATA>
Protection=1, Intensity=1><0>
<17><IAC><SE>
Telephone number:
<IAC><SB><DET><MOVE CURSOR><32><4>
<IAC><SE>
<IAC><SB><DET><FORMAT DATA>
Protection=1, Intensity=1><0>
<24><IAC><SE>
Social Security Number:
<IAC><SB><DET><FORMAT DATA> [Establish a field that doesn't
<Protection=1, Intensity=7> display what is typed into it.]
<0><11><IAC><SE>
<IAC><SB><DET><MOVE CURSOR><32>
<5><IAC><SE>
<IAC><SB><DET><FORMAT FACILITIES> [Get permission to use Blinking
<Blinking><0><IAC><SE> Attribute.]
U:<IAC><SB><DET><FORMAT FACILITIES>
<Repeat, Blinking><Protection,
3 Levels Intensity><IAC><SE>
S:<IAC><SB><DET><FORMAT DATA>
<Blinking=1, Protection=1,
Intensity=1><0><29><IAC><SE>
Your SSN will not be printed.
<IAC><SB><DET><HOME><IAC><SE>
21
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
<IAC><GA>
The previous exchange has placed a form on the screen that looks like:
Name:
Address:
Telephone Number: Social Security Number:
"Your SSN will not be printed."
where the quoted string is blinking.
The terminal user is now free to fill in the form provided. He
positions the cursor at the beginning of the first field (this usually
is done by hitting the tab key) and begins typing. We do not show this
interaction since it does not generate any interaction with the User
Telnet program or the network. After the terminal user has completed
filling in the form, he strikes the transmit key to send the unprotected
part of the form, but first the User Telnet program negotiates the Byte
Macro Option to condense the Field Separator subcommand:
U:<IAC><DO><BM> [Negotiate Byte Macro Option.]
S:<IAC><WILL><BM> [Define decimal 166 to be the
Field Separator subcommand
U:<IAC><SB><BM><DEFINE> (see Appendix 3)]
<166><6><IAC SB DET FIELD
SEPARATOR IAC SE><IAC><SE>
S:<IAC><SB><BM><ACCEPT><166> [The server accepts the macro.]
<IAC><SE>
U:<IAC><SB><DET><DATA TRANSMIT><0><6>
<IAC><SE>
John Doe <166> 1515 Elm St., Urbana, Il 61801
<166> 217-333-9999 <166> 123-45-6789 <166>
S:<IAC><SB><DET><ERASE SCREEN><IAC><SE>
Thank you.
And so on.
22
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Appendix 1 - Subcommands, opcodes and syntax
1 EDIT FACILITIES <Facilty map>
2 ERASE FACILITIES <Facility map>
3 TRANSMIT FACILITIES <Facility map>
4 FORMAT FACILITIES <Facility map 1> <Facility map 2>
5 MOVE CURSOR <x> <y>
6 SKIP TO LINE <y>
7 SKIP TO CHAR <x>
8 UP
9 DOWN
10 LEFT
11 RIGHT
12 HOME
13 LINE INSERT
14 LINE DELETE
15 CHAR INSERT
16 CHAR DELETE
17 READ CURSOR
18 CURSOR POSITION <x><y>
19 REVERSE TAB
20 TRANSMIT SCREEN
21 TRANSMIT UNPROTECTED
22 TRANSMIT LINE
23 TRANSMIT FIELD
24 TRANSMIT REST OF SCREEN
25 TRANSMIT REST OF LINE
26 TRANSMIT REST OF FIELD
27 DATA TRANSMIT <x><y>
28 ERASE SCREEN
29 ERASE LINE
30 ERASE FIELD
31 ERASE REST OF SCREEN
32 ERASE REST OF LINE
33 ERASE REST OF FIELD
34 ERASE UNPROTECTED
35 FORMAT DATA <format map>
36 REPEAT <count><char>
37 SUPPRESS PROTECTION <negotiation>
38 FIELD SEPARATOR
39 FN <code>
40 ERROR <cmd><error code>
23
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Appendix 2 - Error Codes
1 Facility not previously negotiated.
2 Illegal subcommand code.
3 Cursor Address Out of Bounds.
4 Undefined FN value.
4 Can't negotiate acceptable line width.
5 Can't negotiate acceptable page length.
6 Illegal parameter in subcommand.
7 Syntax error in parsing subcommand.
8 Too many parameters in subcommand.
9 Too few parameters in subcommand.
10 Undefined parameter value
11 Unsupported combination of Format Attributes
24
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
Appendix 3 - Use of the Byte Macro Option
One of the major drawbacks of the DET option is that because the
functions are encoded as Telnet option subnegotiations a fairly
high overhead is incurred. A function like Character Insert which
is encoded as a single byte in most terminals requires six bytes in
the DET option. Originally the only other solution that would have
accomplished the same transparency that the use of subcommands
provides would have been to define additional Telnet control
functions. However, since this would entail modification of the
Telnet protocol itself, it was felt that this was not a wise
solution. Since then the Telnet Byte Macro Option (RFC 729) has
been defined. This option allows the user and server Telnets to
map an arbitrary character string into a single byte which is then
transferred over the net. Thus the Byte Macro Option provides the
means for implementations to avoid the overhead for heavily used
subcommands. The rest of this appendix suggests how the Byte Macro
Option should be applied to the DET option.
In keeping with the specification of the Byte Macro Option, macro
bytes will be chosen from the range 128 to 239. For the DET
option, it is suggested that macro bytes be chosen by adding the
subcommand code to 128. In addition, an unofficial DET subcommand
might be defined indicating that each side was willing to support
macro bytes for all subcommands (but not necessarily support all of
the subcommands themselves) according to this algorithm. This
subcommand would be:
IAC SB DET DET-MACRO <negotiation> IAC SE
subcommand code: 254
where <negotiation> may have the values of the Telnet option
negotiation:
251 WILL
252 WONT
253 DO
254 DONT
This subcommand is sent by a Telnet implementation to indicate its
willingness to adopt byte macros for all of the DET subcommands
according to the following algorithm:
25
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
The macro byte for subcommand i will be i+128 and will represent
the following string for parameterless subcommands:
IAC SB DET <subcommand code> IAC SE
and the following string for subcommands with parameters:
IAC SB DET <subcommand code>
The default setting for this subcommand is that the macros are
not in effect, in other words,
IAC SB DET DET-MACRO WONT IAC SE
IAC SB DET DET-MACRO DONT IAC SE
Negotiation of this subcommand follows the same rules as
negotiations of the Telnet options.
26
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
References
1. ADM-1 Interactive Display Terminal Operator's Handbook
Lear-Siegler, Inc. 7410-31.
2. ADM-Interactive Display Terminal Operator's Handbook
Lear-Siegler, Inc. EID, 1974.
3. Burroughs TD 700/800 Reference Manual, Burroughs Corp., 1973
4. Burroughs TD 820 Reference Manual, Burroughs Corp. 1975.
5. CC-40 Communications Station: General Information Manual.
Computer Communication, Inc. Pub. No. MI-1100. 1974.
6. Crocker, David. "Telnet Byte Macro Option," RFC 729, 1977.
7. Data Entry Virtual Terminal Protocol for Euronet, DRAFT, 1977.
8. Day, John. "A Minor Pitfall in the Telnet Protocol,"
RFC 728, 1977.
9. Hazeltine 2000 Desk Top Display Operating Instructions.
Hazeltine IB-1866A, 1870.
10. How to Use the Consul 980: A Terminal Operator's Guide
and Interface Manual. Applied Digital Data Systems, Inc.
98-3000.
11. How to Use the Consul 520: A Terminal Operator's Guide
and Interface Manual. Applied Digital Data Systems, Inc.
52-3000.
12. Honeywell 7700 Series Visual Information Projection (VIP)
Systems: Preliminary Edition. 1973.
13. An Introduction to the IBM 3270 Information Display System.
IBM GA27-2739-4. 1973.
14. Naffah, N. "Protocole Appareil Virtuel type Ecran"
Reseau Cyclades. TER 536. 1976.
27
^L
John Day Data Entry Terminal Option
June 27,1977 NIC 40652
RFC 731
15. Postel, Jon and Crocker, David. "Remote Controlled
Transmission and Echoing Telnet Option", RFC 726
NIC 39237, Mar. 1977.
16. Schicker, Peter. "Virtual Terminal Protocol (Proposal 2).
INWG Protocol Note #32., 1976.
17. UNISCOPE Display Terminal : Programmer Reference . Sperry-
Univac UP-7807 Rev. 2, 1975.
18. Universal Terminal System 400: System Description. Sperry-
Univac UP-8357, 1976.
19. Walden, David C. "Telnet Output Line Width Option."
NIC # 20196, 1973, also in ARPANET Protocol Handbook, 1976.
20. Walden, David C. "Telnet Output Page Size" NIC # 20197,
1973, also in ARPANET Protocol Handbook, 1976.
28
^L
|