summaryrefslogtreecommitdiff
path: root/doc/rfc/rfc7326.txt
blob: 9271901a0ae071e69422cef6359b2565bc39f2e2 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
Internet Engineering Task Force (IETF)                        J. Parello
Request for Comments: 7326                                     B. Claise
Category: Informational                              Cisco Systems, Inc.
ISSN: 2070-1721                                             B. Schoening
                                                  Independent Consultant
                                                              J. Quittek
                                                         NEC Europe Ltd.
                                                          September 2014


                      Energy Management Framework

Abstract

   This document defines a framework for Energy Management (EMAN) for
   devices and device components within, or connected to, communication
   networks.  The framework presents a physical reference model and
   information model.  The information model consists of an Energy
   Management Domain as a set of Energy Objects.  Each Energy Object can
   be attributed with identity, classification, and context.  Energy
   Objects can be monitored and controlled with respect to power, Power
   State, energy, demand, Power Attributes, and battery.  Additionally,
   the framework models relationships and capabilities between Energy
   Objects.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Not all documents
   approved by the IESG are a candidate for any level of Internet
   Standard; see Section 2 of RFC 5741.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc7326.











Parello, et al.               Informational                     [Page 1]
^L
RFC 7326                     EMAN Framework               September 2014


Copyright Notice

   Copyright (c) 2014 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1. Introduction ....................................................3
   2. Terminology .....................................................4
   3. Target Devices ..................................................9
   4. Physical Reference Model .......................................10
   5. Areas Not Covered by the Framework .............................11
   6. Energy Management Abstraction ..................................12
      6.1. Conceptual Model ..........................................12
      6.2. Energy Object (Class) .....................................13
      6.3. Energy Object Attributes ..................................15
      6.4. Measurements ..............................................18
      6.5. Control ...................................................19
      6.6. Relationships .............................................25
   7. Energy Management Information Model ............................29
   8. Modeling Relationships between Devices .........................33
      8.1. Power Source Relationship .................................33
      8.2. Metering Relationship .....................................37
      8.3. Aggregation Relationship ..................................38
   9. Relationship to Other Standards ................................39
   10. Security Considerations .......................................39
      10.1. Security Considerations for SNMP .........................40
   11. IANA Considerations ...........................................41
      11.1. IANA Registration of New Power State Sets ................41
      11.2. Updating the Registration of Existing Power State Sets ...42
   12. References ....................................................43
      12.1. Normative References .....................................43
      12.2. Informative References ...................................44
   13. Acknowledgments ...............................................45
   Appendix A. Information Model Listing .............................46






Parello, et al.               Informational                     [Page 2]
^L
RFC 7326                     EMAN Framework               September 2014


1.  Introduction

   Network Management is often divided into the five main areas defined
   in the ISO Telecommunications Management Network model: Fault,
   Configuration, Accounting, Performance, and Security Management
   (FCAPS) [X.700].  Not covered by this traditional management model is
   Energy Management, which is rapidly becoming a critical area of
   concern worldwide, as seen in [ISO50001].

   This document defines an Energy Management framework for devices
   within, or connected to, communication networks, per the Energy
   Management requirements specified in [RFC6988].  The devices, or the
   components of these devices (such as line cards, fans, and disks),
   can then be monitored and controlled.  Monitoring includes measuring
   power, energy, demand, and attributes of power.  Energy Control can
   be performed by setting a device's or component's state.  The devices
   monitored by this framework can be either of the following:

   o  consumers of energy (such as routers and computer systems) and
      components of such devices (such as line cards, fans, and disks)

   o  producers of energy (like an uninterruptible power supply or
      renewable energy system) and their associated components (such as
      battery cells, inverters, or photovoltaic panels)

   This framework further describes how to identify, classify, and
   provide context for such devices.  While context information is not
   specific to Energy Management, some context attributes are specified
   in the framework, addressing the following use cases:

   o  How important is a device in terms of its business impact?

   o  How should devices be grouped for reporting and searching?

   o  How should a device role be described?

   Guidelines for using context for Energy Management are described.

   The framework introduces the concept of a Power Interface that is
   analogous to a network interface.  A Power Interface is defined as an
   interconnection among devices where energy can be provided, received,
   or both.

   The most basic example of Energy Management is a single device
   reporting information about itself.  In many cases, however, energy
   is not measured by the device itself but is measured upstream in the
   power distribution tree.  For example, a Power Distribution Unit
   (PDU) may measure the energy it supplies to attached devices and



Parello, et al.               Informational                     [Page 3]
^L
RFC 7326                     EMAN Framework               September 2014


   report this to an Energy Management System.  Therefore, devices often
   have relationships to other devices or components in the power
   network.  An Energy Management System (EnMS) generally requires an
   understanding of the power topology (who provides power to whom), the
   Metering topology (who meters whom), and the potential Aggregation
   (who aggregates values of others).

   The relationships build on the Power Interface concept.  The
   different relationships among devices and components, as specified in
   this document, include power source, Metering, and Aggregation
   Relationships.

   The framework does not cover non-electrical equipment, nor does it
   cover energy procurement and manufacturing.

2.  Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

   In this document, these words will appear with the above
   interpretation only when in ALL CAPS.  Lowercase uses of these words
   are not to be interpreted as carrying the significance of RFC 2119
   key words.

   In this section, some terms have a NOTE that is not part of the
   definition itself but accounts for differences between terminologies
   of different standards organizations or further clarifies the
   definition.

   The terms are listed in an order that aids in reading where terms may
   build off a previous term, as opposed to an alphabetical ordering.
   Some terms that are common in electrical engineering or that describe
   common physical items use a lowercase notation.

   Energy Management
      Energy Management is a set of functions for measuring, modeling,
      planning, and optimizing networks to ensure that the network and
      network-attached devices use energy efficiently and appropriately
      for the nature of the application and the cost constraints of the
      organization.

      Reference: Adapted from [TMN].







Parello, et al.               Informational                     [Page 4]
^L
RFC 7326                     EMAN Framework               September 2014


      NOTES:

      1. "Energy Management" refers to the activities, methods,
         procedures, and tools that pertain to measuring, modeling,
         planning, controlling, and optimizing the use of energy in
         networked systems [NMF].

      2. Energy Management is a management domain that is congruent to
         any of the FCAPS areas of management in the ISO/OSI Network
         Management Model [TMN].  Energy Management for communication
         networks and attached devices is a subset or part of an
         organization's greater Energy Management Policies.

   Energy Management System (EnMS)
      An Energy Management System is a combination of hardware and
      software used to administer a network, with the primary purpose of
      Energy Management.

      NOTES:

      1. An Energy Management System according to [ISO50001] (ISO-EnMS)
         is a set of systems or procedures upon which organizations can
         develop and implement an energy policy, set targets and action
         plans, and take into account legal requirements related to
         energy use.  An ISO-EnMS allows organizations to improve energy
         performance and demonstrate conformity to requirements,
         standards, and/or legal requirements.

      2. Example ISO-EnMS: Company A defines a set of policies and
         procedures indicating that there should exist multiple
         computerized systems that will poll energy measurements from
         their meters and pricing / source data from their local
         utility.  Company A specifies that their CFO (Chief Financial
         Officer) should collect information and summarize it quarterly
         to be sent to an accounting firm to produce carbon accounting
         reporting as required by their local government.

      3. For the purposes of EMAN, the definition herein is the
         preferred meaning of an EnMS.  The definition from [ISO50001]
         can be referred to as an ISO Energy Management System
         (ISO-EnMS).

   Energy Monitoring
      Energy Monitoring is a part of Energy Management that deals with
      collecting or reading information from devices to aid in Energy
      Management.





Parello, et al.               Informational                     [Page 5]
^L
RFC 7326                     EMAN Framework               September 2014


   Energy Control
      Energy Control is a part of Energy Management that deals with
      directing influence over devices.

   electrical equipment
      This is a general term that includes materials, fittings, devices,
      appliances, fixtures, apparatus, machines, etc., that are used as
      a part of, or in connection with, an electric installation.

      Reference: [IEEE100].

   non-electrical equipment (mechanical equipment)
      This is a general term that includes materials, fittings, devices,
      appliances, fixtures, apparatus, machines, etc., that are used as
      a part of, or in connection with, non-electrical power
      installations.

      Reference: Adapted from [IEEE100].

   device
      A device is a piece of electrical or non-electrical equipment.

      Reference: Adapted from [IEEE100].

   component
      A component is a part of electrical or non-electrical equipment
      (device).

      Reference: Adapted from [TMN].

   power inlet
      A power inlet (or simply "inlet") is an interface at which a
      device or component receives energy from another device or
      component.

   power outlet
      A power outlet (or simply "outlet") is an interface at which a
      device or component provides energy to another device or
      component.

   energy
      Energy is that which does work or is capable of doing work.  As
      used by electric utilities, it is generally a reference to
      electrical energy and is measured in kilowatt-hours (kWh).

      Reference: [IEEE100].





Parello, et al.               Informational                     [Page 6]
^L
RFC 7326                     EMAN Framework               September 2014


      NOTE:

      1. Energy is the capacity of a system to produce external activity
         or perform work [ISO50001].

   power
      Power is the time rate at which energy is emitted, transferred, or
      received; power is usually expressed in watts (joules per second).

      Reference: [IEEE100].

   demand
      Demand is the average value of power or a related quantity over a
      specified interval of time.  Note: Demand is expressed in
      kilowatts, kilovolt-amperes, kilovars, or other suitable units.

      Reference: [IEEE100].

      NOTE:

      1. While IEEE100 defines demand in kilo measurements, for EMAN we
         use watts with any suitable metric prefix.

   provide energy
      A device (or component) "provides" energy to another device if
      there is an energy flow from this device to the other one.

   receive energy
      A device (or component) "receives" energy from another device if
      there is an energy flow from the other device to this one.

   meter (energy meter)
      A meter is a device intended to measure electrical energy by
      integrating power with respect to time.

      Reference: Adapted from [IEC60050].

   battery
      A battery is one or more cells (consisting of an assembly of
      electrodes, electrolyte, container, terminals, and (usually)
      separators) that are a source and/or store of electric energy.

      Reference: Adapted from [IEC60050].

   Power Interface
      A Power Interface is a power inlet, outlet, or both.





Parello, et al.               Informational                     [Page 7]
^L
RFC 7326                     EMAN Framework               September 2014


   Nameplate Power
      The Nameplate Power is the nominal power of a device as specified
      by the device manufacturer.

   Power Attributes
      Power Attributes are measurements of the electrical current,
      voltage, phase, and frequencies at a given point in an electrical
      power system.

      Reference: Adapted from [IEC60050].

      NOTE:

      1. Power Attributes are not intended to provide any bounds or
         recommended range for the value.  They are simply the reading
         of the value associated with the attribute in question.

   Power Quality
      "Power Quality" refers to characteristics of the electrical
      current, voltage, phase, and frequencies at a given point in an
      electric power system, evaluated against a set of reference
      technical parameters.  These parameters might, in some cases,
      relate to the compatibility between electricity supplied in an
      electric power system and the loads connected to that electric
      power system.

      Reference: [IEC60050].

      NOTE:

      1. Electrical characteristics representing Power Quality
         information are typically required by customer facility Energy
         Management Systems.  Electrical characteristics are not
         intended to satisfy the detailed requirements of Power Quality
         monitoring.  Standards typically also give ranges of allowed
         values; the information attributes are the raw measurements,
         not the "yes/no" determination by the various standards.

      Reference: [ASHRAE-201].












Parello, et al.               Informational                     [Page 8]
^L
RFC 7326                     EMAN Framework               September 2014


   Power State
      A Power State is a condition or mode of a device (or component)
      that broadly characterizes its capabilities, power, and
      responsiveness to input.

      Reference: Adapted from [IEEE1621].

   Power State Set
      A Power State Set is a collection of Power States that comprises a
      named or logical control grouping.

3.  Target Devices

   With Energy Management, there exists a wide variety of devices that
   may be contained in the same deployment as a communication network
   but comprise a separate facility, home, or power distribution
   network.

   Energy Management has special challenges because a power distribution
   network supplies energy to devices and components, while a separate
   communications network monitors and controls the power distribution
   network.

   The target devices for Energy Management are all devices that can be
   monitored or controlled (directly or indirectly) by an Energy
   Management System (EnMS).  These target devices include, for example:

   o  Simple electrical appliances and fixtures

   o  Hosts, such as a PC, a server, or a printer

   o  Switches, routers, base stations, and other network equipment such
      as middleboxes

   o  Components within devices, e.g., a line card inside a switch

   o  Batteries functioning as a device or component that is a store of
      energy

   o  Devices or components that charge or produce energy, such as solar
      cells, charging stations, or generators

   o  Power over Ethernet (PoE) endpoints

   o  Power Distribution Units (PDUs)

   o  Protocol gateway devices for Building Management Systems (BMS)




Parello, et al.               Informational                     [Page 9]
^L
RFC 7326                     EMAN Framework               September 2014


   o  Electrical meters

   o  Sensor controllers with subtended sensors

   Target devices include devices that communicate via the Internet
   Protocol (IP) as well as devices using other means for communication.
   The latter are managed through gateways or proxies that can
   communicate using IP.

4.  Physical Reference Model

   The following reference model describes physical power topologies
   that exist in parallel with a communication topology.  While many
   more topologies can be created with a combination of devices, the
   following are some basic ones that show how Energy Management
   topologies differ from Network Management topologies.

       NOTE: "###" is used to denote a transfer of energy.
             "- >" is used to denote a transfer of information.

                         Basic Energy Management:

                        +--------------------------+
                        | Energy Management System |
                        +--------------------------+
                                    ^  ^
                         monitoring |  | control
                                    v  v
                                +---------+
                                | device  |
                                +---------+


                            Basic Power Supply:

                +-----------------------------------------+
                |         Energy Management System        |
                +-----------------------------------------+
                      ^  ^                       ^  ^
           monitoring |  | control    monitoring |  | control
                      v  v                       v  v
                +--------------+        +-----------------+
                | power source |########|      device     |
                +--------------+        +-----------------+







Parello, et al.               Informational                    [Page 10]
^L
RFC 7326                     EMAN Framework               September 2014


                Single Power Supply with Multiple Devices:

                  +---------------------------------------+
                  |       Energy Management System        |
                  +---------------------------------------+
                     ^  ^                       ^  ^
          monitoring |  | control    monitoring |  | control
                     v  v                       v  v
                  +--------+        +------------------+
                  | power  |########|         device 1 |
                  | source |   #    +------------------+-+
                  +--------+   #######|         device 2 |
                                 #    +------------------+-+
                                 #######|         device 3 |
                                        +------------------+


                Multiple Power Supplies with Single Device:

             +----------------------------------------------+
             |          Energy Management System            |
             +----------------------------------------------+
                 ^  ^              ^  ^              ^  ^
            mon. |  | ctrl.   mon. |  | ctrl.   mon. |  | ctrl.
                 v  v              v  v              v  v
             +----------+      +----------+      +----------+
             | power    |######|  device  |######| power    |
             | source 1 |      |          |      | source 2 |
             +----------+      +----------+      +----------+

5.  Areas Not Covered by the Framework

   While this framework is intended as a framework for Energy Management
   in general, there are some areas that are not covered.

   Non-Electrical Equipment

      The primary focus of this framework is the management of
      electrical equipment.  Non-electrical equipment, which is not
      covered in this framework, could nevertheless be modeled by
      providing interfaces that comply with the framework: for example,
      using the same units for power and energy.  Therefore,
      non-electrical equipment that does not "convert to" or
      "present as" an entity equivalent to electrical equipment is not
      addressed.






Parello, et al.               Informational                    [Page 11]
^L
RFC 7326                     EMAN Framework               September 2014


   Energy Procurement and Manufacturing

      While an EnMS may be a central point for corporate reporting, cost
      computation, environmental impact analysis, and regulatory
      compliance reporting, Energy Management in this framework excludes
      energy procurement and the environmental impact of energy use.

      As such, the framework does not include:

      o  Cost in currency or environmental units of manufacturing a
         device

      o  Embedded carbon or environmental equivalences of a device

      o  Cost in currency or environmental impact to dismantle or
         recycle a device

      o  Supply chain analysis of energy sources for device deployment

      o  Conversion of the usage or production of energy to units
         expressed from the source of that energy (such as the
         greenhouse gas emissions associated with the transfer of energy
         from a diesel source)

6.  Energy Management Abstraction

   This section describes a conceptual model of information that can be
   used for Energy Management.  The classes and categories of attributes
   in the model are described, with a rationale for each.

6.1.  Conceptual Model

   This section describes an information model that addresses issues
   specific to Energy Management and complements existing Network
   Management models.

   An information model for Energy Management will need to describe a
   means to monitor and control devices and components.  The model will
   also need to describe the relationships among, and connections
   between, devices and components.

   This section defines a conceptual model for devices and components
   that is similar to the model used in Network Management: devices,
   components, and interfaces.  This section then defines the additional
   attributes specific to Energy Management for those entities that are
   not available in existing Network Management models.





Parello, et al.               Informational                    [Page 12]
^L
RFC 7326                     EMAN Framework               September 2014


   For modeling the devices and components, this section describes three
   classes denoted by a "(Class)" suffix: a Device (Class), a Component
   (Class), and a Power Interface (Class).  These classes are sub-types
   of an abstract Energy Object (Class).

            Summary of Notation for Modeling Physical Equipment

         Physical         Modeling (Metadata)      Model Instance
         ---------------------------------------------------------
         equipment        Energy Object (Class)    Energy Object

         device           Device (Class)           Device

         component        Component (Class)        Component

         inlet/outlet     Power Interface (Class)  Power Interface

   This section then describes the attributes of an Energy Object
   (Class) for identification, classification, context, control, power,
   and energy.

   Since the interconnections between devices and components for Energy
   Management may have no relation to the interconnections for Network
   Management, the Energy Object (Classes) contain a separate
   Relationships (Class) as an attribute to model these types of
   interconnections.

   The next sections describe each of the classes and categories of
   attributes in the information model.

   Not all of the attributes are mandatory for implementations.
   Specifications describing implementations of the information model in
   this framework need to be explicit about which are mandatory and
   which are optional to implement.

   The formal definitions of the classes and attributes are specified in
   Section 7.

6.2.  Energy Object (Class)

   An Energy Object (Class) represents a piece of equipment that is
   part of, or attached to, a communications network that is monitored
   or controlled or that aids in the management of another device for
   Energy Management.







Parello, et al.               Informational                    [Page 13]
^L
RFC 7326                     EMAN Framework               September 2014


   The Energy Object (Class) is an abstract class that contains the base
   attributes to represent a piece of equipment for Energy Management.
   There are three types of Energy Object (Class): Device (Class),
   Component (Class), and Power Interface (Class).

6.2.1.  Device (Class)

   The Device (Class) is a subclass of Energy Object (Class) that
   represents a physical piece of equipment.

   A Device (Class) instance represents a device that is a consumer,
   producer, meter, distributor, or store of energy.

   A Device (Class) instance may represent a physical device that
   contains other components.

6.2.2.  Component (Class)

   The Component (Class) is a subclass of Energy Object (Class) that
   represents a part of a physical piece of equipment.

6.2.3.  Power Interface (Class)

   A Power Interface (Class) represents the interconnections (inlet,
   outlet) among devices or components where energy can be provided,
   received, or both.

   The Power Interface (Class) is a subclass of Energy Object (Class)
   that represents a physical inlet or outlet.

   There are some similarities between Power Interfaces and network
   interfaces.  A network interface can be set to different states, such
   as sending or receiving data on an attached line.  Similarly, a Power
   Interface can be receiving or providing energy.

   A Power Interface (Class) instance can represent (physically) an AC
   power socket, an AC power cord attached to a device, or an 8P8C
   (RJ45) PoE socket, etc.













Parello, et al.               Informational                    [Page 14]
^L
RFC 7326                     EMAN Framework               September 2014


6.3.  Energy Object Attributes

   This section describes categories of attributes for an Energy Object
   (Class).

6.3.1.  Identification

   A Universally Unique Identifier (UUID) [RFC4122] is used to uniquely
   and persistently identify an Energy Object.

   Every Energy Object has an optional unique human-readable printable
   name.  Possible naming conventions are textual DNS name, Media Access
   Control (MAC) address of the device, interface ifName, or a text
   string uniquely identifying the Energy Object.  As an example, in
   the case of IP phones, the Energy Object name can be the device's
   DNS name.

   Additionally, an alternate key is provided to allow an Energy Object
   to be optionally linked with models in different systems.

6.3.2.  Context: General

   In order to aid in reporting and in differentiation between Energy
   Objects, each object optionally contains information establishing its
   business, site, or organizational context within a deployment.

   The Energy Object (Class) contains a category attribute that broadly
   describes how an instance is used in a deployment.  The category
   indicates whether the Energy Object is primarily functioning as a
   consumer, producer, meter, distributor, or store of energy.

   Given the category and context of an object, an EnMS can summarize or
   analyze measurements for the site.

6.3.3.  Context: Importance

   An Energy Object can provide an importance value in the range of 1 to
   100 to help rank a device's use or relative value to the site.  The
   importance range is from 1 (least important) to 100 (most important).
   The default importance value is 1.

   For example, a typical office environment has several types of
   phones, which can be rated according to their business impact.  A
   public desk phone has a lower importance (for example, 10) than a
   business-critical emergency phone (for example, 100).  As another
   example, a company can consider that a PC and a phone for a customer
   service engineer are more important than a PC and a phone for
   lobby use.



Parello, et al.               Informational                    [Page 15]
^L
RFC 7326                     EMAN Framework               September 2014


   Although EnMS and administrators can establish their own ranking, the
   following example is a broad recommendation for commercial
   deployments [CISCO-EW]:

      90 to 100  Emergency response
      80 to 90   Executive or business-critical
      70 to 79   General or average
      60 to 69   Staff or support
      40 to 59   Public or guest
      1  to 39   Decorative or hospitality

6.3.4.  Context: Keywords

   The Energy Object (Class) contains an attribute with context
   keywords.

   An Energy Object can provide a set of keywords that is a list of tags
   that can be used for grouping, summary reporting (within or between
   Energy Management Domains), and searching.  Potential examples are
   IT, lobby, HumanResources, Accounting, StoreRoom, CustomerSpace,
   router, phone, floor2, or SoftwareLab.

   The specifics of how this tag is represented are left to the MIB
   module or other object definition documents to be based on this
   framework.

   There is no default value for a keyword.  Multiple keywords can be
   assigned to an Energy Object.

6.3.5.  Context: Role

   The Energy Object (Class) contains a role attribute.  The "role
   description" string indicates the primary purpose the Energy Object
   serves in the deployment.  This could be a string representing the
   purpose the Energy Object fulfills in the deployment.

   The specifics of how this tag is represented are left to the MIB
   module or other object definition documents to be based on this
   framework.

   Administrators can define any naming scheme for the role.  As
   guidance, a two-word role that combines the service the Energy Object
   provides, along with type, can be used [IPENERGY].

   Example types of devices: Router, Switch, Light, Phone, WorkStation,
   Server, Display, Kiosk, HVAC.





Parello, et al.               Informational                    [Page 16]
^L
RFC 7326                     EMAN Framework               September 2014


                   Example Services by Line of Business:

         Line of Business     Service
         ------------------------------------------------------
         Education            Student, Faculty, Administration,
                              Athletic

         Finance              Trader, Teller, Fulfillment

         Manufacturing        Assembly, Control, Shipping

         Retail               Advertising, Cashier

         Support              Helpdesk, Management

         Medical              Patient, Administration, Billing

   Role as a two-word string: "Faculty Desktop", "Teller Phone",
   "Shipping HVAC", "Advertising Display", "Helpdesk Kiosk",
   "Administration Switch".

   The specifics of how this tag is represented are left to the MIB
   module or other object definition documents to be based on this
   framework.

6.3.6.  Context: Domain

   The Energy Object (Class) contains a string attribute to indicate
   membership in an Energy Management Domain.  An Energy Management
   Domain can be any collection of Energy Objects in a deployment, but
   it is recommended to map 1:1 with a metered or sub-metered portion of
   the site.

   In building management, a meter refers to the meter provided by the
   utility used for billing and measuring power to an entire building or
   unit within a building.  A sub-meter refers to a customer- or user-
   installed meter that is not used by the utility to bill but is
   instead used to get measurements from portions of a building.

   The specifics of how this tag is represented are left to the MIB
   module or other object definition documents to be based on this
   framework.

   An Energy Object MUST be a member of a single Energy Management
   Domain; therefore, one attribute is provided.






Parello, et al.               Informational                    [Page 17]
^L
RFC 7326                     EMAN Framework               September 2014


6.4.  Measurements

   The Energy Object (Class) contains attributes to describe power,
   energy, and demand measurements.

   An analogy for understanding power versus energy measurements can be
   made to speed and distance in automobiles.  Just as a speedometer
   indicates the rate of change of distance (speed), a power measurement
   indicates the rate of transfer of energy.  The odometer in an
   automobile measures the cumulative distance traveled; similarly, an
   energy measurement indicates the accumulated energy transferred.

   Demand measurements are averages of power measurements over time.
   So, using the same analogy to an automobile: measuring the average
   vehicle speed over multiple intervals of time for a given distance
   traveled, demand is the average power measured over multiple time
   intervals for a given energy value.

   Within this framework, energy will only be quantified in units of
   watt-hours.  Physical devices measuring energy in other units must
   convert values to watt-hours or be represented by Energy Objects that
   convert to watt-hours.

6.4.1.  Measurements: Power

   The Energy Object (Class) contains a Nameplate Power Attribute that
   describes the nominal power as specified by the manufacturer of the
   device.  The EnMS can use the Nameplate Power for provisioning,
   capacity planning, and (potentially) billing.

   The Energy Object (Class) has attributes that describe the present
   power information, along with how that measurement was obtained or
   derived (e.g., actual, estimated, or static).

   A power measurement is qualified with the units, magnitude, and
   direction of power flow and is qualified as to the means by which the
   measurement was made.

   Power measurement magnitude conforms to the [IEC61850] definition of
   unit multiplier for the SI (System International) units of measure.
   Measured values are represented in SI units obtained by BaseValue *
   (10 ^ Scale).  For example, if current power usage of an Energy
   Object is 17, it could be 17 W, 17 mW, 17 kW, or 17 MW, depending on
   the value of the scaling factor.  17 W implies that BaseValue = 17
   and Scale = 0, whereas 17 mW implies that BaseValue = 17 and
   ScaleFactor = -3.





Parello, et al.               Informational                    [Page 18]
^L
RFC 7326                     EMAN Framework               September 2014


   An Energy Object (Class) indicates how the power measurement was
   obtained with a caliber and accuracy attribute that indicates:

   o  Whether the measurements were made at the device itself or at a
      remote source.

   o  Description of the method that was used to measure the power and
      whether this method can distinguish actual or estimated values.

   o  Accuracy for actual measured values.

6.4.2.  Measurements: Power Attributes

   The Energy Object (Class) contains an optional attribute that
   describes Power Attribute information reflecting the electrical
   characteristics of the measurement.  These Power Attributes adhere to
   the [IEC61850-7-2] standard for describing AC measurements.

6.4.3.  Measurements: Energy

   The Energy Object (Class) contains optional attributes that represent
   the energy used, received, produced, and/or stored.  Typically, only
   devices or components that can measure actual power will have the
   ability to measure energy.

6.4.4.  Measurements: Demand

   The Energy Object (Class) contains optional attributes that represent
   demand information over time.  Typically, only devices or components
   that can report actual power are capable of measuring demand.

6.5.  Control

   The Energy Object (Class) contains a Power State Set (Class)
   attribute that represents the set of Power States a device or
   component supports.

   A Power State describes a condition or mode of a device or component.
   While Power States are typically used for control, they may be used
   for monitoring only.

   A device or component is expected to support at least one set of
   Power States consisting of at least two states: an on state and an
   off state.

   There are many existing standards describing device and component
   Power States.  The framework supports modeling a mixed set of Power
   States defined in different standards.  A basic example is given by



Parello, et al.               Informational                    [Page 19]
^L
RFC 7326                     EMAN Framework               September 2014


   the three Power States defined in IEEE1621 [IEEE1621]: on, off, and
   sleep.  The Distributed Management Task Force (DMTF) standards
   organization [DMTF], Advanced Configuration and Power Interface
   (ACPI) specification [ACPI], and Printer Working Group (PWG) all
   define larger numbers of Power States.

   The semantics of a Power State are specified by:

   a) The functionality provided by an Energy Object in this state.

   b) A limitation of the power that an Energy Object uses in this
      state.

   c) A combination of a) and b).

   The semantics of a Power State should be clearly defined.  Limitation
   (curtailment) of the power used by an Energy Object in a state may be
   specified by:

   o  An absolute power value.

   o  A percentage value of power relative to the Energy Object's
      Nameplate Power.

   o  An indication of power relative to another Power State.  For
      example, specify that power in state A is less than in state B.

   o  For supporting Power State management, an Energy Object provides
      statistics on Power States, including the time an Energy Object
      spent in a certain Power State and the number of times an Energy
      Object entered a Power State.

   When requesting an Energy Object to enter a Power State, an
   indication of the Power State's name or number can be used.
   Optionally, an absolute or percentage of Nameplate Power can be
   provided to allow the Energy Object to transition to a nearest or
   equivalent Power State.

   When an Energy Object is set to a particular Power State, the
   represented device or component may be busy.  The Energy Object
   should set the desired Power State and then update the actual Power
   State when the device or component changes.  There are then two Power
   State (Class) control attributes: actual and requested.

   The following sections describe well-known Power States for devices
   and components that should be modeled in the information model.





Parello, et al.               Informational                    [Page 20]
^L
RFC 7326                     EMAN Framework               September 2014


6.5.1.  Power State Sets

   There are several standards and implementations of Power State Sets.
   The Energy Object (Class) supports modeling one or multiple Power
   State Set implementations on the device or component concurrently.

   There are currently three Power State Sets specified by IANA:

      IEEE1621 (256) - [IEEE1621]
      DMTF (512)     - [DMTF]
      EMAN (768)     - [RFC7326]

   The respective specific states related to each Power State Set are
   specified in the following sections.  The guidelines for the
   modification of Power State Sets are specified in the IANA
   Considerations section.

6.5.2.  Power State Set: IEEE1621

   The IEEE1621 Power State Set [IEEE1621] consists of three rudimentary
   states: on, off, or sleep.

   In IEEE1621, devices are limited to the three basic Power States --
   on (2), sleep (1), and off (0).  Any additional Power States are
   variants of one of the basic states, rather than a fourth state
   [IEEE1621].

6.5.3.  Power State Set: DMTF

   The DMTF [DMTF] standards organization has defined a power profile
   standard based on the CIM (Common Information Model), which consists
   of 15 Power States.

   The DMTF standard is targeted for hosts and computers.  Details of
   the semantics of each Power State within the DMTF Power State Set can
   be obtained from the DMTF Power State Management Profile
   specification [DMTF].














Parello, et al.               Informational                    [Page 21]
^L
RFC 7326                     EMAN Framework               September 2014


   The DMTF power profile extends ACPI Power States.  The following
   table provides a mapping between DMTF and ACPI Power State Sets:

       DMTF                                 ACPI
       ------------------------------------------------
       Reserved (0)
       Reserved (1)
       ON (2)                               G0/S0
       Sleep-Light (3)                      G1/S1 G1/S2
       Sleep-Deep (4)                       G1/S3
       Power Cycle (Off-Soft) (5)           G2/S5
       Off-Hard (6)                         G3
       Hibernate (Off-Soft) (7)             G1/S4
       Off-Soft (8)                         G2/S5
       Power Cycle (Off-Hard) (9)           G3
       Master Bus Reset (10)                G2/S5
       Diagnostic Interrupt (11)            G2/S5
       Off-Soft Graceful (12)               G2/S5
       Off-Hard Graceful (13)               G3
       MasterBus Reset Graceful (14)        G2/S5
       Power Cycle Off-Soft Graceful (15)   G2/S5
       Power Cycle Off-Hard Graceful (16)   G3

6.5.4.  Power State Set: IETF EMAN

   The EMAN Power States are an expansion of the basic Power States as
   defined in [IEEE1621] plus the addition of the Power States defined
   in [ACPI] and [DMTF].  Therefore, in addition to the non-operational
   states as defined in [ACPI] and [DMTF] standards, several
   intermediate operational states have been defined.

   Physical devices and components are expected to support the EMAN
   Power State Set or to be modeled via an Energy Object the supports
   these states.

   An Energy Object may implement fewer or more Power States than a
   particular EMAN Power State Set specifies.  In that case, the Energy
   Object implementation can determine its own mapping to the predefined
   EMAN Power States within the EMAN Power State Set.

   There are twelve EMAN Power States that expand on [IEEE1621].  The
   expanded list of Power States is derived from [CISCO-EW] and is
   divided into six operational states and six non-operational states.








Parello, et al.               Informational                    [Page 22]
^L
RFC 7326                     EMAN Framework               September 2014


   The lowest non-operational state is 0, and the highest is 5.  Each
   non-operational state corresponds to an [ACPI] Global and System
   state between G3 (hard-off) and G1 (sleeping).  Each operational
   state represents a performance state and may be mapped to [ACPI]
   states P0 (maximum performance power) through P5 (minimum performance
   and minimum power).

   In each of the non-operational states (from mechoff(0) to ready(5)),
   the Power State preceding it is expected to have a lower Power value
   and a longer delay in returning to an operational state:

      mechoff(0): An off state where no Energy Object features are
         available.  The Energy Object is unavailable.  No energy is
         being consumed, and the power connector can be removed.

      softoff(1): Similar to mechoff(0), but some components remain
         powered or receive trace power so that the Energy Object can be
         awakened from its off state.  In softoff(1), no context is
         saved, and the device typically requires a complete boot when
         awakened.

      hibernate(2): No Energy Object features are available.  The Energy
         Object may be awakened without requiring a complete boot, but
         the time for availability is longer than sleep(3).  An example
         for state hibernate(2) is a save-to-disk state where DRAM
         context is not maintained.  Typically, energy consumption is
         zero or close to zero.

      sleep(3): No Energy Object features are available, except for
         out-of-band management, such as wake-up mechanisms.  The time
         for availability is longer than standby(4).  An example for
         state sleep(3) is a save-to-RAM state, where DRAM context is
         maintained.  Typically, energy consumption is close to zero.

      standby(4): No Energy Object features are available, except for
         out-of-band management, such as wake-up mechanisms.  This mode
         is analogous to cold-standby.  The time for availability is
         longer than ready(5).  For example, processor context may not
         be maintained.  Typically, energy consumption is close to zero.

      ready(5): No Energy Object features are available, except for
         out-of-band management, such as wake-up mechanisms.  This mode
         is analogous to hot-standby.  The Energy Object can be quickly
         transitioned into an operational state.  For example,
         processors are not executing, but processor context is
         maintained.





Parello, et al.               Informational                    [Page 23]
^L
RFC 7326                     EMAN Framework               September 2014


      lowMinus(6): Indicates that some Energy Object features may not be
         available and the Energy Object has taken measures or selected
         options to use less energy than low(7).

      low(7): Indicates that some Energy Object features may not be
         available and the Energy Object has taken measures or selected
         options to use less energy than mediumMinus(8).

      mediumMinus(8): Indicates that all Energy Object features are
         available but the Energy Object has taken measures or selected
         options to use less energy than medium(9).

      medium(9): Indicates that all Energy Object features are available
         but the Energy Object has taken measures or selected options to
         use less energy than highMinus(10).

      highMinus(10): Indicates that all Energy Object features are
         available and the Energy Object has taken measures or selected
         options to use less energy than high(11).

      high(11): Indicates that all Energy Object features are available
         and the Energy Object may use the maximum energy as indicated
         by the Nameplate Power.

6.5.5.  Power State Sets Comparison

   A comparison of Power States from different Power State Sets can be
   seen in the following tables:

      Non-operational states:

      IEEE1621  DMTF           ACPI         EMAN
      --------------------------------------------------
      off       Off-Hard       G3/S5        mechoff(0)
      off       Off-Soft       G2/S5        softoff(1)
      off       Hibernate      G1/S4        hibernate(2)
      sleep     Sleep-Deep     G1/S3        sleep(3)
      sleep     Sleep-Light    G1/S2        standby(4)
      sleep     Sleep-Light    G1/S1        ready(5)












Parello, et al.               Informational                    [Page 24]
^L
RFC 7326                     EMAN Framework               September 2014


      Operational states:

      IEEE1621  DMTF         ACPI           EMAN
      ----------------------------------------------------
      on        on           G0/S0/P5       lowMinus(6)
      on        on           G0/S0/P4       low(7)
      on        on           G0/S0/P3       mediumMinus(8)
      on        on           G0/S0/P2       medium(9)
      on        on           G0/S0/P1       highMinus(10)
      on        on           G0/S0/P0       high(11)

6.6.  Relationships

   The Energy Object (Class) contains a set of Relationship (Class)
   attributes to model the relationships between devices and components.
   Two Energy Objects can establish an Energy Object Relationship to
   model the deployment topology with respect to Energy Management.

   Relationships are modeled with a Relationship (Class) that contains
   the UUID of the other participant in the relationship and a name that
   describes the type of relationship [CHEN].  The types of
   relationships are Power Source, Metering, and Aggregations.

   o  A Power Source Relationship is a relationship where one Energy
      Object provides power to one or more Energy Objects.  The Power
      Source Relationship gives a view of the physical wiring topology
      -- for example, a data center server receiving power from two
      specific Power Interfaces from two different PDUs.

      Note: A Power Source Relationship may or may not change as the
      direction of power changes between two Energy Objects.  The
      relationship may remain to indicate that the change of power
      direction was unintended or an error condition.

   o  A Metering Relationship is a relationship where one Energy Object
      measures power, energy, demand, or Power Attributes of one or more
      other Energy Objects.  The Metering Relationship gives the view of
      the Metering topology.  Physical meters can be placed anywhere in
      a power distribution tree.  For example, utility meters monitor
      and report accumulated power consumption of the entire building.
      Logically, the Metering topology overlaps with the wiring
      topology, as meters are connected to the wiring topology.  A
      typical example is meters that clamp onto the existing wiring.








Parello, et al.               Informational                    [Page 25]
^L
RFC 7326                     EMAN Framework               September 2014


   o  An Aggregation Relationship is a relationship where one Energy
      Object aggregates Energy Management information of one or more
      other Energy Objects.  The Aggregation Relationship gives a model
      of devices that may aggregate (sum, average, etc.) values for
      other devices.  The Aggregation Relationship is slightly different
      compared to the other relationships, as this refers more to a
      management function.

   In some situations, it is not possible to discover the Energy Object
   Relationships, and an EnMS or administrator must set them.  Given
   that relationships can be assigned manually, the following sections
   describe guidelines for use.

6.6.1.  Relationship Conventions and Guidelines

   This Energy Management framework does not impose many "MUST" rules
   related to Energy Object Relationships.  There are always corner
   cases that can be excluded by making stricter specifications for
   relationships.  However, the framework proposes a series of
   guidelines, indicated with "SHOULD" and "MAY".

6.6.2.  Guidelines: Power Source

   Power Source Relationships are intended to identify the connections
   between Power Interfaces.  This is analogous to a Layer 2 connection
   in networking devices (a "one-hop connection").

   The preferred modeling would be for Power Interfaces to participate
   in Power Source Relationships.  In some cases, Energy Objects may not
   have the capability to model Power Interfaces.  Therefore, a Power
   Source Relationship can be established between two Energy Objects or
   two non-connected Power Interfaces.

   Strictly speaking, while components and Power Interfaces on the same
   Device do provide or receive energy from each other, the Power Source
   Relationship is intended to show energy transfer between Devices.
   Therefore, the relationship is implied when on the same Device.

   An Energy Object SHOULD NOT establish a Power Source Relationship
   with a component.

   o  A Power Source Relationship SHOULD be established with the next
      known Power Interface in the wiring topology.








Parello, et al.               Informational                    [Page 26]
^L
RFC 7326                     EMAN Framework               September 2014


   o  The next known Power Interface in the wiring topology would be the
      next device implementing the framework.  In some cases, the domain
      of devices under management may include some devices that do not
      implement the framework.  In these cases, the Power Source
      Relationship can be established with the next device in the
      topology that implements the framework and logically shows the
      Power Source of the device.

   o  Transitive Power Source Relationships SHOULD NOT be established.
      For example, if Energy Object A has a Power Source Relationship
      "Poweredby" with Energy Object B, and if Energy Object B has a
      Power Source Relationship "Poweredby" with Energy Object C, then
      Energy Object A SHOULD NOT have a Power Source Relationship
      "Poweredby" with Energy Object C.

6.6.3.  Guidelines: Metering Relationship

   Metering Relationships are intended to show when one device acting as
   a meter is measuring the power or energy at a point in a power
   distribution system.  Since one point of a power distribution system
   may cover many devices within a wiring topology, this relationship
   type can be seen as a set.

   Some devices may include hardware that can measure power for
   components, outlets, or the entire device.  For example, some PDUs
   may have the ability to measure power for each outlet and are
   commonly referred to as metered-by-outlet.  Others may be able to
   control power at each power outlet but can only measure power at the
   power inlet -- commonly referred to as metered-by-device.

   While the Metering Relationship could be used to represent a device
   as metered-by-outlet or metered-by-device, the Metering Relationship
   SHOULD be used to model the relationship between a meter and all
   devices covered by the meter downstream in the power distribution
   system.

   In general:

   o  A Metering Relationship MAY be established with any other Energy
      Object, component, or Power Interface.

   o  Transitive Metering Relationships MAY be used.

   o  When there is a series of meters for one Energy Object, the Energy
      Object MAY establish a Metering Relationship with one or more of
      the meters.





Parello, et al.               Informational                    [Page 27]
^L
RFC 7326                     EMAN Framework               September 2014


6.6.4.  Guidelines: Aggregation

   Aggregation Relationships are intended to identify when one device is
   used to accumulate values from other devices.  Typically, this is for
   energy or power values among devices and not for components or Power
   Interfaces on the same device.

   The intent of Aggregation Relationships is to indicate when one
   device is providing aggregate values for a set of other devices when
   it is not obvious from the power source or simple containment within
   a device.

   Establishing Aggregation Relationships within the same device would
   make modeling more complex, and the aggregated values can be implied
   from the use of power inlets, outlet, and Energy Object values on the
   same device.

   Since an EnMS is naturally a point of Aggregation, it is not
   necessary to model Aggregation for Energy Management Systems.

   The Aggregation Relationship is intended for power and energy.  It
   MAY be used for Aggregation of other values from the information
   model, but the rules and logical ability to aggregate each attribute
   are out of scope for this document.

   In general:

   o  A Device SHOULD NOT establish an Aggregation Relationship with
      components contained on the same device.

   o  A Device SHOULD NOT establish an Aggregation Relationship with the
      Power Interfaces contained on the same device.

   o  A Device SHOULD NOT establish an Aggregation Relationship with an
      EnMS.

   o  Aggregators SHOULD log or provide notification in the case of
      errors or missing values while performing Aggregation.













Parello, et al.               Informational                    [Page 28]
^L
RFC 7326                     EMAN Framework               September 2014


6.6.5.  Energy Object Relationship Extensions

   This framework for Energy Management is based on three relationship
   types: Aggregation, Metering, and Power Source.

   This framework is defined with possible future extension of new
   Energy Object Relationships in mind.

   For example:

   o  Some Devices that may not be IP connected could be modeled with a
      proxy relationship to an Energy Object within the domain.  This
      type of proxy relationship is left for further development.

   o  A Power Distribution Unit (PDU) that allows devices and components
      like outlets to be "ganged" together as a logical entity for
      simplified management purposes could be modeled with an extension
      called a "gang relationship", whose semantics would specify the
      Energy Objects' grouping.

7.  Energy Management Information Model

   This section presents an information model expression of the concepts
   in this framework as a reference for implementers.  The information
   model is implemented as MIB modules in the different related IETF
   EMAN documents.  However, other programming structures with different
   data models could be used as well.

   Data modeling specifications of this information model may, where
   needed, specify which attributes are required or optional.

   Syntax

      Unified Modeling
      Language (UML)
      Construct
      [ISO-IEC-19501-2005]  Equivalent Notation
      --------------------  ----------------------------------
      Notes                 // Notes

      Class
         (Generalization)   CLASS name {member..}
      Subclass
         (Specialization)   CLASS subclass
                                 EXTENDS superclass {member..}
      Class Member
         (Attribute)        attribute : type




Parello, et al.               Informational                    [Page 29]
^L
RFC 7326                     EMAN Framework               September 2014


   Model

      CLASS EnergyObject {

            // identification / classification
            index        : int
            name         : string
            identifier   : uuid
            alternatekey : string

            // context
            domainName      : string
            role            : string
            keywords [0..n] : string
            importance      : int

            // relationship
            relationships [0..n] : Relationship

            // measurements
            nameplate    : Nameplate
            power        : PowerMeasurement
            energy       : EnergyMeasurement
            demand       : DemandMeasurement

            // control
            powerControl [0..n] : PowerStateSet
      }

      CLASS PowerInterface EXTENDS EnergyObject {
            eoIfType : enum { inlet, outlet, both }
      }

      CLASS Device EXTENDS EnergyObject {
            eocategory             : enum { producer, consumer, meter,
      distributor, store }
            powerInterfaces [0..n] : PowerInterface
            components [0..n]      : Component
      }

      CLASS Component EXTENDS EnergyObject {
            eocategory             : enum { producer, consumer, meter,
      distributor, store }
            powerInterfaces [0..n] : PowerInterface
            components [0..n]      : Component
      }





Parello, et al.               Informational                    [Page 30]
^L
RFC 7326                     EMAN Framework               September 2014


      CLASS Nameplate {
            nominalPower : PowerMeasurement
            details      : URI
      }

      CLASS Relationship {
            relationshipType    : enum { meters, meteredby, powers,
      poweredby, aggregates, aggregatedby }
            relationshipObject  : uuid
      }

      CLASS Measurement {
            multiplier : enum { -24..24 }
            caliber    : enum { actual, estimated, static }
            accuracy   : enum { 0..10000 } // hundreds of percent
      }

      CLASS PowerMeasurement EXTENDS Measurement {
            value          : long
            units          : "W"
            powerAttribute : PowerAttribute
      }

      CLASS EnergyMeasurement EXTENDS Measurement {
            startTime : time
            units     : "kWh"
            provided  : long
            used      : long
            produced  : long
            stored    : long

      }

      CLASS TimedMeasurement EXTENDS Measurement {
            startTime  : timestamp
            value      : Measurement
            maximum    : Measurement
      }

      CLASS TimeInterval {
            value      : long
            units      : enum { seconds, milliseconds,... }
      }








Parello, et al.               Informational                    [Page 31]
^L
RFC 7326                     EMAN Framework               September 2014


      CLASS DemandMeasurement EXTENDS Measurement {
            intervalLength      : TimeInterval
            intervals           : long
            intervalMode        : enum { periodic, sliding, total }
            intervalWindow      : TimeInterval
            sampleRate          : TimeInterval
            status              : enum { active, inactive }
            measurements [0..n] : TimedMeasurements
      }

      CLASS PowerStateSet {
            powerSetIdentifier : int
            name               : string
            powerStates [0..n] : PowerState
            operState          : int
            adminState         : int
            reason             : string
            configuredTime     : timestamp
      }

      CLASS PowerState {
            powerStateIdentifier : int
            name                 : string
            cardinality          : int
            maximumPower         : PowerMeasurement
            totalTimeInState     : time
            entryCount           : long
      }

      CLASS PowerAttribute {
            acQuality  : ACQuality
      }

      CLASS ACQuality {
            acConfiguration    : enum { SNGL, DEL, WYE }
            avgVoltage         : long
            avgCurrent         : long
            thdCurrent         : long
            frequency          : long
            unitMultiplier     : int
            accuracy           : int
            totalActivePower   : long
            totalReactivePower : long
            totalApparentPower : long
            totalPowerFactor   : long
      }





Parello, et al.               Informational                    [Page 32]
^L
RFC 7326                     EMAN Framework               September 2014


      CLASS DelPhase EXTENDS ACQuality {
            phaseToNextPhaseVoltage : long
            thdVoltage              : long
      }

      CLASS WYEPhase EXTENDS ACQuality {
            phaseToNeutralVoltage : long
            thdCurrent            : long
            thdVoltage            : long
            avgCurrent            : long
      }

8.  Modeling Relationships between Devices

   In this section, we give examples of how to use the EMAN information
   model to model physical topologies.  Where applicable, we show how
   the framework can be applied when devices can be modeled with Power
   Interfaces.  We also show how the framework can be applied when
   devices cannot be modeled with Power Interfaces but only monitored or
   controlled as a whole.  For instance, a PDU may only be able to
   measure power and energy for the entire unit without the ability to
   distinguish among the inlets or outlets.

8.1.  Power Source Relationship

   The Power Source Relationship is used to model the interconnections
   between devices, components, and/or Power Interfaces to indicate the
   source of energy for a device.

   In the following examples, we show variations on modeling the
   reference topologies using relationships.

   Given for all cases:

   Device W: A computer with one power supply.  Power Interface 1 is an
      inlet for Device W.

   Device X: A computer with two power supplies.  Power Interface 1 and
      Power Interface 2 are both inlets for Device X.

   Device Y: A PDU with multiple Power Interfaces numbered 0..10.  Power
      Interface 0 is an inlet, and Power Interfaces 1..10 are outlets.

   Device Z: A PDU with multiple Power Interfaces numbered 0..10.  Power
      Interface 0 is an inlet, and Power Interfaces 1..10 are outlets.






Parello, et al.               Informational                    [Page 33]
^L
RFC 7326                     EMAN Framework               September 2014


   Case 1: Simple Device with one Source

      Physical Topology:

         o  Device W inlet 1 is plugged into Device Y outlet 8.

      With Power Interfaces:

         o  Device W has an Energy Object representing the computer
            itself as well as one Power Interface defined as an inlet.

         o  Device Y would have an Energy Object representing the PDU
            itself (the Device), with Power Interface 0 defined as an
            inlet and Power Interfaces 1..10 defined as outlets.

         The interfaces of the devices would have a Power Source
         Relationship such that:

         Device W inlet 1 is powered by Device Y outlet 8.

            +-------+------+       poweredBy +------+----------+
            | PDU Y | PI 8 |-----------------| PI 1 | Device W |
            +-------+------+ powers          +------+----------+

      Without Power Interfaces:

         o  Device W has an Energy Object representing the computer.

         o  Device Y would have an Energy Object representing the PDU.

         The devices would have a Power Source Relationship such that:

         Device W is powered by Device Y.

            +----------+       poweredBy +------------+
            |  PDU Y   |-----------------|  Device W  |
            +----------+ powers          +------------+














Parello, et al.               Informational                    [Page 34]
^L
RFC 7326                     EMAN Framework               September 2014


   Case 2: Multiple Inlets

      Physical Topology:

      o  Device X inlet 1 is plugged into Device Y outlet 8.

      o  Device X inlet 2 is plugged into Device Y outlet 9.

      With Power Interfaces:

         o  Device X has an Energy Object representing the computer
            itself.  It contains two Power Interfaces defined as inlets.

         o  Device Y would have an Energy Object representing the PDU
            itself (the Device), with Power Interface 0 defined as an
            inlet and Power Interfaces 1..10 defined as outlets.

         The interfaces of the devices would have a Power Source
         Relationship such that:

         Device X inlet 1 is powered by Device Y outlet 8.

         Device X inlet 2 is powered by Device Y outlet 9.

            +-------+------+        poweredBy+------+----------+
            |       | PI 8 |-----------------| PI 1 |          |
            |       |      |powers           |      |          |
            | PDU Y +------+        poweredBy+------+ Device X |
            |       | PI 9 |-----------------| PI 2 |          |
            |       |      |powers           |      |          |
            +-------+------+                 +------+----------+

      Without Power Interfaces:

         o  Device X has an Energy Object representing the computer.
            Device Y has an Energy Object representing the PDU.

         The devices would have a Power Source Relationship such that:

         Device X is powered by Device Y.

            +----------+       poweredBy +------------+
            |  PDU Y   |-----------------|  Device X  |
            +----------+ powers          +------------+







Parello, et al.               Informational                    [Page 35]
^L
RFC 7326                     EMAN Framework               September 2014


   Case 3: Multiple Sources

      Physical Topology:

      o  Device X inlet 1 is plugged into Device Y outlet 8.

      o  Device X inlet 2 is plugged into Device Z outlet 9.

      With Power Interfaces:

         o  Device X has an Energy Object representing the computer
            itself.  It contains two Power Interfaces defined as inlets.

         o  Device Y would have an Energy Object representing the PDU
            itself (the Device), with Power Interface 0 defined as an
            inlet and Power Interfaces 1..10 defined as outlets.

         o  Device Z would have an Energy Object representing the PDU
            itself (the Device), with Power Interface 0 defined as an
            inlet and Power Interfaces 1..10 defined as outlets.

         The interfaces of the devices would have a Power Source
         Relationship such that:

         Device X inlet 1 is powered by Device Y outlet 8.

         Device X inlet 2 is powered by Device Z outlet 9.

            +-------+------+        poweredBy+------+----------+
            | PDU Y | PI 8 |-----------------| PI 1 |          |
            |       |      |powers           |      |          |
            +-------+------+                 +------+          |
                                                    | Device X |
            +-------+------+        poweredBy+------+          |
            | PDU Z | PI 9 |-----------------| PI 2 |          |
            |       |      |powers           |      |          |
            +-------+------+                 +------+----------+

      Without Power Interfaces:

         o  Device X has an Energy Object representing the computer.
            Devices Y and Z would both have respective Energy Objects
            representing each entire PDU.








Parello, et al.               Informational                    [Page 36]
^L
RFC 7326                     EMAN Framework               September 2014


         The devices would have a Power Source Relationship such that:

         Device X is powered by Device Y and powered by Device Z.

            +----------+           poweredBy +------------+
            |  PDU Y   |---------------------|  Device X  |
            +----------+ powers              +------------+

            +----------+           poweredBy +------------+
            |  PDU Z   |---------------------|  Device X  |
            +----------+ powers              +------------+

8.2.  Metering Relationship

   A meter in a power distribution system can logically measure the
   power or energy for all devices downstream from the meter in the
   power distribution system.  As such, a Metering Relationship can be
   seen as a relationship between a meter and all of the devices
   downstream from the meter.

   We define in this case a Metering Relationship between a meter and
   devices downstream from the meter.

     +-----+---+    meteredBy +--------+   poweredBy +-------+
     |Meter| PI|--------------| switch |-------------| phone |
     +-----+---+ meters       +--------+ powers      +-------+
             |                                           |
             |                                 meteredBy |
             +-------------------------------------------+
              meters

   In cases where the Power Source topology cannot be discovered or
   derived from the information available in the Energy Management
   Domain, the Metering topology can be used to relate the upstream
   meter to the downstream devices in the absence of specific Power
   Source Relationships.















Parello, et al.               Informational                    [Page 37]
^L
RFC 7326                     EMAN Framework               September 2014


   A Metering Relationship can occur between devices that are not
   directly connected, as shown in the following figure:

                          +---------------+
                          |   Device 1    |
                          +---------------+
                          |      PI       |
                          +---------------+
                                  |
                          +---------------+
                          |     Meter     |
                          +---------------+
                                  .
                                  .
                                  .
                 meters        meters           meters
           +----------+   +----------+   +-----------+
           | Device A |   | Device B |   | Device C  |
           +----------+   +----------+   +-----------+

   An analogy to communications networks would be modeling connections
   between servers (meters) and clients (devices) when the complete
   Layer 2 topology between the servers and clients is not known.

8.3.  Aggregation Relationship

   Some devices can act as Aggregation points for other devices.  For
   example, a PDU controller device may contain the summation of power
   and energy readings for many PDU devices.  The PDU controller will
   have aggregate values for power and energy for a group of PDU
   devices.

   This Aggregation is independent of the physical power or
   communication topology.

   The functions that the Aggregation point may perform include the
   calculation of values such as average, count, maximum, median,
   minimum, or the listing (collection) of the Aggregation values, etc.

   Based on IETF experience gained on Aggregations [RFC7015], the
   Aggregation function in the EMAN framework is limited to the
   summation.

   When Aggregation occurs across a set of entities, values to be
   aggregated may be missing for some entities.  The EMAN framework does
   not specify how these should be treated, as different implementations
   may have good reason to take different approaches.  One common
   treatment is to define the Aggregation as missing if any of the



Parello, et al.               Informational                    [Page 38]
^L
RFC 7326                     EMAN Framework               September 2014


   constituent elements are missing (useful to be most precise).
   Another is to treat the missing value as zero (useful to have
   continuous data streams).

   The specifications of Aggregation functions are out of the scope of
   the EMAN framework but must be clearly specified by the equipment
   vendor.

9.  Relationship to Other Standards

   This Energy Management framework uses, as much as possible, existing
   standards, especially with respect to information modeling and data
   modeling [RFC3444].

   The data model for power- and energy-related objects is based on
   [IEC61850].

   Specific examples include:

   o  The scaling factor, which represents Energy Object usage
      magnitude, conforms to the [IEC61850] definition of unit
      multiplier for the SI (System International) units of measure.

   o  The electrical characteristics are based on the ANSI and IEC
      Standards, which require that we use an accuracy class for power
      measurement.  ANSI and IEC define the following accuracy classes
      for power measurement:

      - IEC 62053-22 and 60044-1 classes 0.1, 0.2, 0.5, 1, and 3.

      - ANSI C12.20 classes 0.2 and 0.5.

   o  The electrical characteristics and quality adhere closely to the
        [IEC61850-7-4] standard for describing AC measurements.

   o  The Power State definitions are based on the DMTF Power State
        Profile and ACPI models, with operational state extensions.

10.  Security Considerations

   Regarding the data attributes specified here, some or all may be
   considered sensitive or vulnerable in some network environments.
   Reading or writing these attributes without proper protection such as
   encryption or access authorization will have negative effects on
   network capabilities.  Event logs for audit purposes on configuration
   and other changes should be generated according to current





Parello, et al.               Informational                    [Page 39]
^L
RFC 7326                     EMAN Framework               September 2014


   authorization, audit, and accounting principles to facilitate
   investigations (compromise or benign misconfigurations) or any
   reporting requirements.

   The information and control capabilities specified in this framework
   could be exploited, to the detriment of a site or deployment.
   Implementers of the framework SHOULD examine and mitigate security
   threats with respect to these new capabilities.

   "User-based Security Model (USM) for version 3 of the Simple Network
   Management Protocol (SNMPv3)" [RFC3414] presents a good description
   of threats and mitigations for SNMPv3 that can be used as a guide for
   implementations of this framework using other protocols.

10.1.  Security Considerations for SNMP

   Readable objects in MIB modules (i.e., objects with a MAX-ACCESS
   other than not-accessible) may be considered sensitive or vulnerable
   in some network environments.  It is important to control GET and/or
   NOTIFY access to these objects and possibly to encrypt the values of
   these objects when sending them over the network via SNMP.

   The support for SET operations in a non-secure environment without
   proper protection can have a negative effect on network operations.

   For example:

   o  Unauthorized changes to the Energy Management Domain or business
      context of a device will result in misreporting or interruption of
      power.

   o  Unauthorized changes to a Power State will disrupt the power
      settings of the different devices and therefore the state of
      functionality of the respective devices.

   o  Unauthorized changes to the demand history will disrupt proper
      accounting of energy usage.

   With respect to data transport, SNMP versions prior to SNMPv3 did not
   include adequate security.  Even if the network itself is secure (for
   example, by using IPsec), there is still no secure control over who
   on the secure network is allowed to access and GET/SET
   (read/change/create/delete) the objects in these MIB modules.

   It is recommended that implementers consider the security features as
   provided by the SNMPv3 framework (see [RFC3411]), including full
   support for the SNMPv3 cryptographic mechanisms (for authentication
   and confidentiality).



Parello, et al.               Informational                    [Page 40]
^L
RFC 7326                     EMAN Framework               September 2014


   Further, deployment of SNMP versions prior to SNMPv3 is not
   recommended.  Instead, it is recommended to deploy SNMPv3 and to
   enable cryptographic security.  It is then a customer/operator
   responsibility to ensure that the SNMP entity giving access to an
   instance of these MIB modules is properly configured to give access
   to the objects only to those principals (users) that have legitimate
   rights to GET or SET (change/create/delete) them.

11.  IANA Considerations

11.1.  IANA Registration of New Power State Sets

   This document specifies an initial set of Power State Sets.  The list
   of these Power State Sets with their numeric identifiers is given in
   Section 6.  IANA maintains the lists of Power State Sets.

   New assignments for a Power State Set are administered by IANA
   through Expert Review [RFC5226], i.e., review by one of a group of
   experts designated by an IETF Area Director.  The group of experts
   must check the requested state for completeness and accuracy of the
   description.  A pure vendor-specific implementation of a Power State
   Set shall not be adopted, since it would lead to proliferation of
   Power State Sets.

   Power States in a Power State Set are limited to 255 distinct values.
   A new Power State Set must be assigned the next available numeric
   identifier that is a multiple of 256.

11.1.1.  IANA Registration of the IEEE1621 Power State Set

   This document specifies a set of values for the IEEE1621 Power State
   Set [IEEE1621].  The list of these values with their identifiers is
   given in Section 6.5.2.  IANA created a new registry for IEEE1621
   Power State Set identifiers and filled it with the initial list of
   identifiers.

   New assignments (or, potentially, deprecation) for the IEEE1621 Power
   State Set are administered by IANA through Expert Review [RFC5226].

11.1.2.  IANA Registration of the DMTF Power State Set

   This document specifies a set of values for the DMTF Power State Set
   [DMTF].  The list of these values with their identifiers is given in
   Section 6.5.3.  IANA has created a new registry for DMTF Power State
   Set identifiers and filled it with the initial list of identifiers.

   New assignments (or, potentially, deprecation) for the DMTF Power
   State Set are administered by IANA through Expert Review [RFC5226].



Parello, et al.               Informational                    [Page 41]
^L
RFC 7326                     EMAN Framework               September 2014


   The group of experts must check for conformance with the DMTF
   standard [DMTF] in addition to checking for completeness and accuracy
   of the description.

11.1.3.  IANA Registration of the EMAN Power State Set

   This document specifies a set of values for the EMAN Power State Set.
   The list of these values with their identifiers is given in
   Section 6.5.4.  IANA has created a new registry for EMAN Power State
   Set identifiers and filled it with the initial list of identifiers.

   New assignments (or, potentially, deprecation) for the EMAN Power
   State Set are administered by IANA through Expert Review [RFC5226].

11.2.  Updating the Registration of Existing Power State Sets

   With the evolution of standards, over time, it may be important to
   deprecate some of the existing Power State Sets, or to add or
   deprecate some Power States within a Power State Set.

   The registrant shall post an Internet-Draft with the clear
   specification on deprecation of Power State Sets or Power States
   registered with IANA.  The deprecation or addition shall be
   administered by IANA through Expert Review [RFC5226], i.e., review by
   one of a group of experts designated by an IETF Area Director.  The
   process should also allow for a mechanism for cases where others have
   significant objections to claims regarding the deprecation of a
   registration.























Parello, et al.               Informational                    [Page 42]
^L
RFC 7326                     EMAN Framework               September 2014


12.  References

12.1.  Normative References

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC3411]  Harrington, D., Presuhn, R., and B. Wijnen, "An
              Architecture for Describing Simple Network Management
              Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
              December 2002.

   [RFC3414]  Blumenthal, U. and B. Wijnen, "User-based Security Model
              (USM) for version 3 of the Simple Network Management
              Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.

   [RFC3444]  Pras, A. and J. Schoenwaelder, "On the Difference between
              Information Models and Data Models", RFC 3444,
              January 2003.

   [RFC4122]  Leach, P., Mealling, M., and R. Salz, "A Universally
              Unique IDentifier (UUID) URN Namespace", RFC 4122,
              July 2005.

   [RFC5226]  Narten, T. and H. Alvestrand, "Guidelines for Writing an
              IANA Considerations Section in RFCs", BCP 26, RFC 5226,
              May 2008.

   [RFC6933]  Bierman, A., Romascanu, D., Quittek, J., and M.
              Chandramouli, "Entity MIB (Version 4)", RFC 6933,
              May 2013.

   [RFC6988]  Quittek, J., Ed., Chandramouli, M., Winter, R., Dietz, T.,
              and B. Claise, "Requirements for Energy Management",
              RFC 6988, September 2013.

   [ISO-IEC-19501-2005]
              ISO/IEC 19501:2005, Information technology, Open
              Distributed Processing -- Unified Modeling Language (UML)
              Version 1.4.2, January 2005.











Parello, et al.               Informational                    [Page 43]
^L
RFC 7326                     EMAN Framework               September 2014


12.2.  Informative References

   [RFC3986]  Berners-Lee, T., Fielding, R., and L. Masinter, "Uniform
              Resource Identifier (URI): Generic Syntax", STD 66,
              RFC 3986, January 2005.

   [RFC7015]  Trammell, B., Wagner, A., and B. Claise, "Flow Aggregation
              for the IP Flow Information Export (IPFIX) Protocol",
              RFC 7015, September 2013.

   [ACPI]     "Advanced Configuration and Power Interface
              Specification", October 2006,
              <http://www.acpi.info/spec30b.htm>.

   [IEEE1621] "Standard for User Interface Elements in Power Control of
              Electronic Devices Employed in Office/Consumer
              Environments", IEEE 1621, December 2004.

   [NMF]      Clemm, A., "Network Management Fundamentals",
              ISBN-10: 1-58720-137-2, Cisco Press, November 2006.

   [TMN]      International Telecommunication Union, "TMN management
              functions", ITU-T Recommendation M.3400, February 2000.

   [IEEE100]  "The Authoritative Dictionary of IEEE Standards Terms",
              <http://ieeexplore.ieee.org/xpl/
              mostRecentIssue.jsp?punumber=4116785>.

   [ISO50001] "ISO 50001:2011 Energy management systems -- Requirements
              with guidance for use", June 2011, <http://www.iso.org/>.

   [IEC60050] "International Electrotechnical Vocabulary",
              <http://www.electropedia.org/iev/iev.nsf/
              welcome?openform>.

   [IEC61850] "Power Utility Automation",
              <http://www.iec.ch/smartgrid/standards/>.

   [IEC61850-7-2]
              "Abstract communication service interface (ACSI)",
              <http://www.iec.ch/smartgrid/standards/>.

   [IEC61850-7-4]
              "Compatible logical node classes and data classes",
              <http://www.iec.ch/smartgrid/standards/>.






Parello, et al.               Informational                    [Page 44]
^L
RFC 7326                     EMAN Framework               September 2014


   [DMTF]     "Power State Management Profile", DMTF DSP1027
              Version 2.0.0, December 2009,
              <http://www.dmtf.org/sites/default/files/standards/
              documents/DSP1027_2.0.0.pdf>.

   [IPENERGY] Aldrich, R. and J. Parello, "IP-Enabled Energy Management:
              A Proven Strategy for Administering Energy as a Service",
              2010, Wiley Publishing.

   [X.700]    CCITT Recommendation X.700, "Management framework for Open
              Systems Interconnection (OSI) for CCITT applications",
              September 1992.

   [ASHRAE-201]
              "ASHRAE Standard Project Committee 201 (SPC 201) Facility
              Smart Grid Information Model",
              <http://spc201.ashraepcs.org>.

   [CHEN]     Chen, P., "The Entity-Relationship Model: Toward a Unified
              View of Data", ACM Transactions on Database Systems
              (TODS), March 1976.

   [CISCO-EW] Parello, J., Saville, R., and S. Kramling, "Cisco
              EnergyWise Design Guide", Cisco Validated Design (CVD),
              September 2011,
              <http://www.cisco.com/en/US/docs/solutions/
              Enterprise/Borderless_Networks/Energy_Management/
              energywisedg.html>.

13.  Acknowledgments

   The authors would like to thank Michael Brown for his editorial work,
   which improved the text dramatically.  Thanks to Rolf Winter for his
   feedback, and to Bill Mielke for his feedback and very detailed
   review.  Thanks to Bruce Nordman for brainstorming, with numerous
   conference calls and discussions.  Finally, the authors would like to
   thank the EMAN chairs: Nevil Brownlee, Bruce Nordman, and Tom Nadeau.














Parello, et al.               Informational                    [Page 45]
^L
RFC 7326                     EMAN Framework               September 2014


Appendix A.  Information Model Listing

   A. EnergyObject (Class):

   r  index         Integer            An [RFC6933] entPhysicalIndex

   w  name          String             An [RFC6933] entPhysicalName

   r  identifier    uuid               An [RFC6933] entPhysicalUUID

   rw alternatekey  String             A manufacturer-defined string
                                       that can be used to identify the
                                       Energy Object

   rw domainName    String             The name of an Energy Management
                                       Domain for the Energy Object

   rw role          String             An administratively assigned name
                                       to indicate the purpose an
                                       Energy Object serves in the
                                       network

   rw keywords      String             A list of keywords or [0..n] tags
                                       that can be used to group Energy
                                       Objects for reporting or
                                       searching

   rw importance    Integer            Specifies a ranking of how
                                       important the Energy Object is
                                       (on a scale of 1 to 100) compared
                                       with other Energy Objects

   rw relationships Relationship       A list of relationships between
      [0..n]                           this Energy Object and other
                                       Energy Objects

   r  nameplate     Nameplate          The nominal PowerMeasurement of
                                       the Energy Object as specified by
                                       the device manufacturer

   r  power         PowerMeasurement   The present power measurement of
                                       the Energy Object

   r  energy        EnergyMeasurement  The present energy measurement
                                       for the Energy Object

   r  demand        DemandMeasurement  The present demand measurement
                                       for the Energy Object



Parello, et al.               Informational                    [Page 46]
^L
RFC 7326                     EMAN Framework               September 2014


   r  powerControl  PowerStateSet      A list of Power States Sets the
      [0..n]                           Energy Object supports


   B. PowerInterface (Class) inherits from EnergyObject:

   r  eoIfType      Enumeration        Indicates whether the Power
                                       Interface is an inlet, outlet,
                                       or both


   C. Device (Class) inherits from EnergyObject:

   rw eocategory       Enumeration     Broadly indicates whether
                                       the Device is a producer,
                                       consumer, meter, distributor,
                                       or store of energy

   r  powerInterfaces  PowerInterface  A list of PowerInterfaces
      [0..n]                           contained in this Device

   r  components       Component       A list of components
      [0..n]                           contained in this Device


   D. Component (Class) inherits from EnergyObject:

   rw eocategory       Enumeration     Broadly indicates whether the
                                       component is a producer,
                                       consumer, meter, distributor, or
                                       store of energy

   r  powerInterfaces  PowerInterface  A list of PowerInterfaces
      [0..n]                           contained in this component

   r  components       Component       A list of components contained
      [0..n]                           in this component














Parello, et al.               Informational                    [Page 47]
^L
RFC 7326                     EMAN Framework               September 2014


   E. Nameplate (Class):

   r  nominalPower     PowerMeasurement  The nominal power of the Energy
                                         as specified by the device
                                         manufacturer

   rw details          URI               An [RFC3986] URI that links to
                                         manufacturer information about
                                         the nominal power of a device


   F. Relationship (Class):

   rw relationshipType    Enumeration   A description of the
                                        relationship, indicating
                                        meters, meteredby, powers,
                                        poweredby, aggregates, or
                                        aggregatedby

   rw relationshipObject  uuid          An [RFC6933] entPhysicalUUID
                                        that indicates the other
                                        participating Energy Object in
                                        the relationship


   G. Measurement (Class):

   r  multiplier  Enumeration    The magnitude of the Measurement
                                 in the range -24..24

   r  caliber     Enumeration    Specifies how the Measurement was
                                 obtained -- actual, estimated, or
                                 static

   r  accuracy    Enumeration    Specifies the accuracy of the
                                 measurement, if applicable, as
                                 0..10000, indicating hundreds of
                                 percent


   H. PowerMeasurement (Class) inherits from Measurement:

   r value          Long             A measurement value of
                                     power

   r units          "W"              The units of measure for
                                     the power -- "Watts"




Parello, et al.               Informational                    [Page 48]
^L
RFC 7326                     EMAN Framework               September 2014


   r powerAttribute PowerAttribute   Measurement of the electrical
                                     current -- voltage, phase, and/or
                                     frequencies for the
                                     PowerMeasurement


   I. EnergyMeasurement (Class) inherits from Measurement:

   r startTime  Time          Specifies the start time of the
                              EnergyMeasurement interval

   r units      "kWh"         The units of measure for the energy --
                              kilowatt-hours

   r provided   Long          A measurement of energy provided

   r used       Long          A measurement of energy used/consumed

   r produced   Long          A measurement of energy produced

   r stored     Long          A measurement of energy stored


   J. TimedMeasurement (Class) inherits from Measurement:

   r  startTime timestamp     A start time of a measurement

   r  value     Measurement   A measurement value

   r  maximum   Measurement   A maximum value measured since a previous
                              timestamp


   K. TimeInterval (Class):

   r  value     Long          A value of time

   r  units     Enumeration   A magnitude of time, expressed as seconds
                              with an SI prefix (milliseconds, etc.)


   L. DemandMeasurement (Class) inherits from Measurement:

   rw intervalLength  TimeInterval     The length of time over which to
                                       compute average energy

   rw intervals       Long             The number of intervals that can
                                       be measured



Parello, et al.               Informational                    [Page 49]
^L
RFC 7326                     EMAN Framework               September 2014


   rw intervalMode    Enumeration      The mode of interval
                                       measurement -- periodic, sliding,
                                       or total

   rw intervalWindow  TimeInterval     The duration between the starting
                                       time of one sliding window and
                                       the next starting time

   rw sampleRate      TimeInterval     The sampling rate at which to
                                       poll power in order to compute
                                       demand

   rw status          Enumeration      A control to start or stop demand
                                       measurement -- active or inactive

   r  measurements    TimedMeasurement A collection of TimedMeasurements
      [0..n]                           to compute demand


   M. PowerStateSet (Class):

   r  powerSetIdentifier Integer       An IANA-assigned value indicating
                                       a Power State Set

   r  name               String        A Power State Set name

   r  powerStates        PowerState    A set of Power States for the
      [0..n]                           given identifier

   rw operState          Integer       The current operational Power
                                       State

   rw adminState         Integer       The desired Power State

   rw reason             String        Describes the reason
                                       for the adminState

   r  configuredTime     timestamp     Indicates the time of
                                       the desired Power State


   N. PowerState (Class):

   r  powerStateIdentifier Integer           An IANA-assigned value
                                             indicating a Power State

   r  name                 String            A name for the Power State




Parello, et al.               Informational                    [Page 50]
^L
RFC 7326                     EMAN Framework               September 2014


   r  cardinality          Integer           A value indicating an
                                             ordering of the Power State

   rw maximumPower         PowerMeasurement  Indicates the maximum power
                                             for the Energy Object at
                                             this Power State

   r  totalTimeInState     Time              Indicates the total time
                                             an Energy Object has been
                                             in this Power State since
                                             the last reset

   r  entryCount           Long              Indicates the number of
                                             times the Energy Object
                                             has entered or changed to
                                             this state


   O. PowerAttribute (Class):

   r acQuality          ACQuality    Describes AC Power Attributes for
                                     a Measurement

   P. ACQuality (Class):

   r acConfiguration    Enumeration  Describes the physical
                                     configuration of alternating
                                     current as single phase (SNGL),
                                     three-phase delta (DEL), or
                                     three-phase Y (WYE)

   r avgVoltage         Long         The average of the voltage measured
                                     over an integral number of AC
                                     cycles [IEC61850-7-4] 'Vol'

   r avgCurrent         Long         The current per phase
                                     [IEC61850-7-4] 'Amp'

   r thdCurrent         Long         A calculated value for the current
                                     Total Harmonic Distortion (THD).
                                     The method of calculation is not
                                     specified [IEC61850-7-4] 'ThdAmp'

   r frequency          Long         Basic frequency of the AC circuit
                                     [IEC61850-7-4] 'Hz'

   r unitMultiplier     Integer      Magnitude of watts for the usage
                                     value in this instance



Parello, et al.               Informational                    [Page 51]
^L
RFC 7326                     EMAN Framework               September 2014


   r accuracy           Integer      Percentage value in 100ths
                                     of a percent, representing the
                                     presumed accuracy of active,
                                     reactive, and apparent power
                                     in this instance

   r totalActivePower   Long         A measured value of the actual
                                     power delivered to or consumed by
                                     the load [IEC61850-7-4] 'TotW'

   r totalReactivePower Long         A measured value of the reactive
                                     portion of the apparent power
                                     [IEC61850-7-4] 'TotVAr'

   r totalApparentPower Long         A measured value of the voltage
                                     and current, which determines the
                                     apparent power as the vector sum of
                                     real and reactive power
                                     [IEC61850-7-4] 'TotVA'

   r totalPowerFactor   Long         A measured value of the ratio of
                                     the real power flowing to the load
                                     versus the apparent power
                                     [IEC61850-7-4] 'TotPF'


   Q. DelPhase (Class) inherits from ACQuality:

   r phaseToNext      Long      A measured value of phase to
      PhaseVoltage              next phase voltages where the
                                next phase is [IEC61850-7-4]
                                'PPV'

   r thdVoltage       Long      A calculated value for the
                                voltage Total Harmonic Distortion
                                (THD) for phase to next phase.
                                The method of calculation is not
                                specified [IEC61850-7-4] 'ThdPPV'













Parello, et al.               Informational                    [Page 52]
^L
RFC 7326                     EMAN Framework               September 2014


   R. WYEPhase (Class) inherits from ACQuality:

   r phaseToNeutral  Long   A measured value of phase to
      Voltage               neutral voltage [IEC61850-7-4]
                            'PhV'

   r thdCurrent      Long   A calculated value for the current
                            Total Harmonic Distortion (THD).
                            The method of calculation is not
                            specified [IEC61850-7-4] 'ThdA'

   r thdVoltage      Long   A calculated value of the voltage
                            THD for phase to neutral
                            [IEC61850-7-4] 'ThdPhV'

   r avgCurrent      Long   A measured value of phase currents
                            [IEC61850-7-4] 'A'


































Parello, et al.               Informational                    [Page 53]
^L
RFC 7326                     EMAN Framework               September 2014


Authors' Addresses

   John Parello
   Cisco Systems, Inc.
   3550 Cisco Way
   San Jose, CA  95134
   US

   Phone: +1 408 525 2339
   EMail: jparello@cisco.com


   Benoit Claise
   Cisco Systems, Inc.
   De Kleetlaan 6a b1
   Diegem 1813
   BE

   Phone: +32 2 704 5622
   EMail: bclaise@cisco.com


   Brad Schoening
   44 Rivers Edge Drive
   Little Silver, NJ  07739
   US

   EMail: brad.schoening@verizon.net


   Juergen Quittek
   NEC Europe Ltd.
   Network Laboratories
   Kurfuersten-Anlage 36
   69115 Heidelberg
   Germany

   Phone: +49 6221 90511 15
   EMail: quittek@netlab.nec.de












Parello, et al.               Informational                    [Page 54]
^L