1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
|
Internet Engineering Task Force (IETF) J. Parello
Request for Comments: 7461 B. Claise
Category: Standards Track M. Chandramouli
ISSN: 2070-1721 Cisco Systems, Inc.
March 2015
Energy Object Context MIB
Abstract
This document defines a subset of a Management Information Base (MIB)
for energy management of devices. The module addresses device
identification, context information, and the energy relationships
between devices.
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Further information on
Internet Standards is available in Section 2 of RFC 5741.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc7461.
Copyright Notice
Copyright (c) 2015 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Parello, et al. Standards Track [Page 1]
^L
RFC 7461 Energy Object Context MIB March 2015
Table of Contents
1. Introduction ....................................................2
1.1. Energy Management Document Overview ........................2
1.2. Conventions Used in This Document ..........................3
2. The Internet-Standard Management Framework ......................3
3. Terminology .....................................................4
4. Architecture Concepts Applied to the MIB Module .................4
4.1. Energy Object Identification ...............................8
4.2. Energy Object Context ......................................9
4.3. Links to Other Identifiers ................................10
4.4. Energy Object Relationships ...............................11
4.5. Energy Object Identity Persistence ........................12
5. MIB Definitions ................................................12
6. Security Considerations ........................................27
7. IANA Considerations ............................................28
8. References .....................................................29
8.1. Normative References ......................................29
8.2. Informative References ....................................30
Acknowledgments ...................................................31
Authors' Addresses ................................................32
1. Introduction
The Energy Management (EMAN) standards provide a specification for
Energy Management. This document defines a subset of a Management
Information Base (MIB) for use with network management protocols for
Energy monitoring of network devices and devices attached to the
network and possibly extending to devices in the industrial
automation setting with a network interface.
The focus of the MIB module specified in this document is on the
identification of Energy Objects and reporting the context and
relationships of Energy Objects as defined in [RFC7326]. The module
addresses Energy Object identification, Energy Object context, and
Energy Object relationships.
1.1. Energy Management Document Overview
This document specifies the Energy Object Context (ENERGY-OBJECT-
CONTEXT-MIB) and IANA Energy Relationship (IANA-ENERGY-RELATION-MIB)
modules. The Energy Object Context MIB module specifies MIB objects
for identification of Energy Objects, and reporting context and
relationship of an Energy Object. The IANA Energy Relationship MIB
module specifies the first version of the IANA-maintained definitions
of relationships between Energy Objects.
Parello, et al. Standards Track [Page 2]
^L
RFC 7461 Energy Object Context MIB March 2015
Firstly, to illustrate the importance of energy monitoring in
networks and, secondly, to list some of the important areas to be
addressed by the Energy Management Framework [RFC7326], several use
cases and network scenarios are presented in the EMAN applicability
statement document [EMAN-AS]. In addition, for each scenario, the
target devices for energy management, and how those devices powered
and metered are also presented. To address the network scenarios,
requirements for power and energy monitoring for networking devices
are specified in [RFC6988]. Based on the requirements in [RFC6988],
[RFC7326] presents a solution approach.
Accordingly, the scope of the MIB modules in this document is in
accordance to the requirements specified in [RFC6988] and the
concepts from [RFC7326].
This document is based on the Energy Management Framework [RFC7326]
and meets the requirements on identification of Energy Objects and
their context and relationships as specified in the Energy Management
requirements document [RFC6988].
A second MIB module meeting the EMAN requirements [RFC6988] the
Monitoring and Control MIB for Power and Energy [RFC7460], monitors
the Energy Objects for Power States, for the Power and Energy
consumption. Power State monitoring includes: retrieving Power
States, Power State properties, current Power State, Power State
transitions, and Power State statistics. In addition, this MIB
module provides the Power Characteristics properties of the Power and
Energy, along with optional characteristics.
The applicability statement document [EMAN-AS] provides the list of
use cases, describes the common aspects between existing Energy
standards and the EMAN standard, and shows how the EMAN framework
relates to other frameworks.
1.2. Conventions Used in This Document
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in
[RFC2119].
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Parello, et al. Standards Track [Page 3]
^L
RFC 7461 Energy Object Context MIB March 2015
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies MIB
modules that are compliant with SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
3. Terminology
Please refer to [RFC7326] for the definitions of the following
terminology used in this document.
Energy Management
Energy Management System (EnMS)
Energy Monitoring
Energy Control
electrical equipment
non-electrical equipment (mechanical equipment)
device
component
power inlet
power outlet
energy
power
demand
provide energy
receive energy
meter (energy meter)
battery
Power Interface
Nameplate Power
Power Attributes
Power Quality
Power State
Power State Set
4. Architecture Concepts Applied to the MIB Module
This section describes the basic concepts specified in the Energy
Management Framework [RFC7326], with specific information related to
the MIB modules specified in this document.
Parello, et al. Standards Track [Page 4]
^L
RFC 7461 Energy Object Context MIB March 2015
The Energy Object Context (ENERGY-OBJECT-CONTEXT-MIB) MIB module in
this document specifies MIB objects for the identification of Energy
Objects and reporting context and relationship of an Energy Object.
The managed objects are contained in two tables: eoTable and
eoRelationTable.
The first table, eoTable, focuses on the link to the other MIB
modules, on identification, and on the context of the Energy Object.
The second table, eoRelationTable, specifies the relationships
between Energy Objects. This is a simplified representation of the
relationship between Energy Objects.
A "smidump-style" tree presentation of the MIB modules contained in
the document is presented. The meaning of the three symbols in is a
compressed representation of the object's MAX-ACCESS clause, which
may have the following values:
"not-accessible"->"---"
"accessible-for-notify"->"--n"
"read-only"->"r-n"
"read-write"->"rwn"
+- eoTable(1)
|
+- eoEntry(1) [entPhysicalIndex]
|
+-- r-n PethPsePortIndexOrZero eoEthPortIndex(1)
+-- r-n PethPsePortGroupIndexOrZero eoEthPortGrpIndex(2)
+-- r-n LldpPortNumberOrZero eoLldpPortNumber(3)
+-- rwn MacAddress eoMgmtMacAddress(4)
+-- r-n InetAddressType eoMgmtAddressType(5)
+-- r-n InetAddress eoMgmtAddress(6)
+-- r-n OCTET STRING eoMgmtDNSName(7)
+-- rwn SnmpAdminString eoDomainName(8)
+-- rwn SnmpAdminString eoRoleDescription(9)
+-- rwn EnergyObjectKeywordList eoKeywords(10)
+-- rwn Integer32 eoImportance(11)
+-- r-n INTEGER eoPowerCategory(12)
+-- rwn SnmpAdminString eoAlternateKey(13)
+-- r-n INTEGER eoPowerInterfaceType(14)
Parello, et al. Standards Track [Page 5]
^L
RFC 7461 Energy Object Context MIB March 2015
+- eoRelationTable(2)
|
+- eoRelationEntry(1) [entPhysicalIndex, eoRelationIndex]
|
+-- --n Integer32 eoRelationIndex(1)
+-- rwn UUIDorZero eoRelationID(2)
+-- rwn IANAEnergyRelationship eoRelationship(3)
+-- rwn RowStatus eoRelationStatus(4)
+-- rwn StorageType eoRelationStorageType(5)
The following Unified Modeling Language (UML) diagram illustrates the
relationship of the MIB objects in the eoTable, eoRelationTable, and
ENTITY-MIB. The MIB objects describe the identity, context, and
relationship of an Energy Object. The UML diagram, furthermore,
contains objects from the ENTITY-MIB [RFC6933].
Parello, et al. Standards Track [Page 6]
^L
RFC 7461 Energy Object Context MIB March 2015
+--------------------------+
| EO Context Information |
| ------------------------ |
| eoRoleDescription |
| eoKeywords |
| eoImportance |
| eoPowerCategory |
| eoPowerInterfaceType |
| eoDomainName |
+--------------------------+
^
|
+------------------------------+
|--- | EO Identification |
| | ---------------------------- |
| | entPhysicalIndex (*) |
| | entPhysicalName (*) |
| | entPhysicalUUID (*) |
| | entPhysicalClass (*) |
| --------------------------------
| +------------------------------+
|---> | Link to other identifiers |
| |------------------------------|
| | eoEthPortIndex (**) |
| | eoEthPortGrpIndex (**) |
| | eoLldpPortNumber (***) |
| | |
| | eoMgmtMacAddress (optional) |
| | eoMgmtAddressType (optional) |
| | eoMgmtAddress (optional) |
| | eoMgmtDNSName (optional) |
| | eoAlternateKey |
| +------------------------------+
| +------------------------------+
|---> | EO Relationship |
| ---------------------------- |
| eoRelationIndex |
| eoRelationID |
| eoRelationship |
| eoRelationStatus |
| eoRelationStorageType |
+------------------------------+
(*) Compliance with entity4CRCompliance ENTITY-MIB [RFC6933]
(**) Link with the Power over Ethernet MIB [RFC3621]
(***) Link with LLDP MIBs [LLDP-MIB] [LLDP-MED-MIB]
Figure 1: MIB Objects Grouping
Parello, et al. Standards Track [Page 7]
^L
RFC 7461 Energy Object Context MIB March 2015
As displayed in Figure 1, the MIB objects can be classified in
different logical grouping of MIB objects.
1) The Energy Object Identification. See Section 5.1 "Energy Object
Identification". Devices and their sub-components are
characterized by the power-related attributes of a physical entity
present in the ENTITY-MIB [RFC6933].
2) The Context Information. See Section 4.1 "Energy Object Context".
3) The links to other MIB modules. See Section 4.3 "Links to Other
Identifiers".
4) The Energy Object Relationships specific information. See Section
4.4 "Energy Object Relationships".
5) The Energy Object Identity Persistence. See Section 4.5 "Energy
Object Identity Persistence".
4.1. Energy Object Identification
Refer to the "Identification" section in [RFC7326] for background
information about Energy Objects.
Every Energy Object MUST implement the unique index,
entPhysicalIndex, entPhysicalName, entPhysicalClass, and
entPhysicalUUID from the ENTITY-MIB [RFC6933]. Module Compliance
with respect to entity4CRCompliance of ENTITY-MIB MUST be supported,
which requires a limited number of objects supported
(entPhysicalIndex, entPhysicalName, entPhysicalClass, and
entPhysicalUUID). entPhysicalIndex is used as index for the Energy
Object in the ENERGY-OBJECT-CONTEXT-MIB module. Every Energy Object
MUST have a printable name assigned to it. Energy Objects MUST
implement the entPhysicalName object specified in the ENTITY-MIB
[RFC6933], which must contain the Energy Object name.
For the ENERGY-OBJECT-CONTEXT-MIB compliance, every Energy Object
instance MUST implement the entPhysicalUUID from the ENTITY-MIB
[RFC6933].
As displayed in [RFC4122], the following is an example of the string
representation of a Universally Unique Identifier (UUID) as a URN:
urn:uuid:f81d4fae-7dec-11d0-a765-00a0c91e6bf6.
For example, to understand the relationship between Energy Object
Components and Energy Objects, the ENTITY-MIB physical containment
tree [RFC6933] MUST be implemented.
Parello, et al. Standards Track [Page 8]
^L
RFC 7461 Energy Object Context MIB March 2015
A second example deals with one of the ENTITY-MIB extensions: if the
Energy Object temperature is required, the managed objects from the
ENTITY-SENSOR-MIB [RFC3433] should be supported.
Each Energy Object MUST belong to a single Energy Management Domain
or in other words, an Energy Object cannot belong to more than one
Energy Management Domain. Refer to the "Context: Domain" section in
[RFC7326] for background information. The eoDomainName, which is an
element of the eoTable, is a read-write MIB object. The Energy
Management Domain should map 1:1 with a metered or sub-metered
portion of the network. The Energy Management Domain MUST be
configured on the Energy Object. The Energy Object MAY inherit some
of the domain parameters (possibly domain name, some of the context
information such as role or keywords, importance) from the Energy
Object or the Energy Management Domain MAY be configured directly in
an Energy Object.
When an Energy Object acts as a Power Aggregator, the Energy Objects
for which Power should be aggregated MUST be members of the same
Energy Management Domain, specified by the eoDomainName MIB Object.
4.2. Energy Object Context
Refer to the "Context: Domain" section in [RFC7326] for background
information.
An Energy Object must provide a value for eoImportance in the range
of 1-100 to help differentiate the use or relative value of the
device. The importance range is from 1 (least important) to 100
(most important). The default importance value is 1.
An Energy Object can provide a set of eoKeywords. These keywords are
a list of tags that can be used for grouping and summary reporting
within or between Energy Management Domains.
An Energy Object can have Power Interfaces and those interfaces can
be classified as Power Inlet, Power Outlet, or both.
An Energy Object can be classified based on the physical properties
of the Energy Object. That Energy Object can be classified as
consuming power or supplying power to other devices or that Energy
Object can perform both of those functions and finally, an Energy
Object can be a passive meter.
Additionally, an Energy Object can provide an eoRoleDescription
string that indicates the purpose the Energy Object serves in the
network.
Parello, et al. Standards Track [Page 9]
^L
RFC 7461 Energy Object Context MIB March 2015
4.3. Links to Other Identifiers
While the entPhysicalIndex is the primary index for all MIB objects
in the ENERGY-OBJECT-CONTEXT-MIB module, the Energy Management
Systems (EnMS) must be able to make the link with the identifier(s)
in other supported MIB modules.
If the Energy Object is a Power over Ethernet (PoE) port, and if the
Power over Ethernet MIB [RFC3621] is supported by the SNMP agent
managing the Energy Object, then the Energy Objects eoethPortIndex
and eoethPortGrpIndex MUST contain the corresponding values of
pethPsePortIndex and pethPsePortGroupIndex [RFC3621].
If the LLDP-MED MIB [LLDP-MIB] is supported by the Energy Object SNMP
agent, then the Energy Object eoLldpPortNumber MUST contain the
corresponding lldpLocPortNum from the LLDP MIB.
The intent behind the links to the other MIB module identifier(s) is
to correlate the instances in the different MIB modules. This will
allow the ENERGY-OBJECT-CONTEXT-MIB module to reference other MIB
modules in cases where the Power over Ethernet and the LLDP MIB
modules are supported by the SNMP agent. Some use cases may not
implement either of these two MIB modules for the Energy Objects.
However, in situations where either of these two MIB modules are
implemented, the EnMS must be able to correlate the instances in the
different MIB modules.
The eoAlternateKey object specifies an alternate key string that can
be used to identify the Energy Object. Since an EnMS may need to
correlate objects across management systems, this alternate key is
provided to facilitate such a link. This optional value is intended
as a foreign key or alternate identifier for a manufacturer or EnMS
to use to correlate the unique Energy Object Id in other systems or
namespaces. If an alternate key is not available or is not
applicable, then the value is the zero-length string.
An Energy Object can have additional MIB objects that can be used for
easier identification by the EnMS. The optional objects
eoMgmtMacAddress, eoMgmtAddressType, and eoMgmtDNSName can be used to
help identify the relationship between the Energy Objects and other
NMS objects. These objects can be used as an alternate key to help
link the Energy Object with other keyed information that may be
stored within the EnMS(s). For the optional objects that may not be
included in some vendor implementations, the expected behavior when
those objects are polled is a response noSuchInstance.
Parello, et al. Standards Track [Page 10]
^L
RFC 7461 Energy Object Context MIB March 2015
4.4. Energy Object Relationships
Refer to the "Relationships" section in [RFC7326] for the definition
and background information. In order to link two Energy Objects, a
separate table (eoRelationTable) has been introduced in this MIB
module.
Each Energy Object can have one or more Energy Object relationships
with other Energy Objects. The relationship between Energy Objects
is specified in eoRelationTable. The relationship between the Energy
Objects is specified with the entPhysicalIndex of the Energy Object
and the UUID of the remote Energy Object. The UUID MUST comply to
the RFC 4122 specifications. It is important to note that it is
possible that an Energy Object may not have an Energy Object
relationship with other Energy Objects.
The following relationships between Energy Objects have been
considered in the eoRelationTable.
Metering Relationship -> meteredBy / metering
Power Source Relationship -> poweredBy / powering
Aggregation Relationship -> aggregatedBy / aggregating
Energy Object B has a "meteredBy" relationship with Energy Object A,
if the energy consumption of Energy Object B is measured by Energy
Object A. Equivalently, it is possible to indicate that Energy
Object A has a "metering" relationship with Energy Object B.
Energy Object B has a "poweredBy" relationship with Energy Object A,
if the power source of Energy Object B is Energy Object A.
Equivalently, it is possible to indicate that Energy Object A has a
"powering" relationship with Energy Object B.
Energy Object B has "aggregatedBy" relationship with Energy Object A,
if Energy Object A is an aggregation point for energy usage of Energy
Object B. Equivalently, it is possible to indicate that Energy
Object A has "aggregating" relationship with Energy Object B.
The IANA-ENERGY-RELATION-MIB module in Section 5 below specifies the
first version of the IANA-maintained definitions of relationships.
This way, for Energy Relationships, new textual conventions can be
specified, without updating the primary Energy Object Context MIB
module.
Parello, et al. Standards Track [Page 11]
^L
RFC 7461 Energy Object Context MIB March 2015
4.5. Energy Object Identity Persistence
In some situations, the Energy Object identity information should be
persistent even after a device reload. For example, in a static
setup where a switch monitors a series of connected PoE phones, there
is a clear benefit for the EnMS if the Energy Object Identification
and all associated information persist, as it saves a network
discovery. However, in other situations, such as a wireless access
point monitoring the mobile user PCs, there is not much advantage to
persist the Energy Object Information. The identity information of
an Energy Object should be persisted and there is value in the
writable MIB objects persisted.
5. MIB Definitions
-- ************************************************************
--
--
-- This MIB is used for describing the identity and the
-- context information of Energy Objects in network
--
--
-- *************************************************************
ENERGY-OBJECT-CONTEXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
mib-2, Integer32
FROM SNMPv2-SMI -- RFC 2578
TEXTUAL-CONVENTION, MacAddress, TruthValue,
RowStatus, StorageType
FROM SNMPv2-TC -- RFC 2579
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC 3411
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB -- RFC 4001
entPhysicalIndex
FROM ENTITY-MIB -- RFC 6933
UUIDorZero
FROM UUID-TC-MIB -- RFC 6933
IANAEnergyRelationship
FROM IANA-ENERGY-RELATION-MIB;
Parello, et al. Standards Track [Page 12]
^L
RFC 7461 Energy Object Context MIB March 2015
energyObjectContextMIB MODULE-IDENTITY
LAST-UPDATED "201502090000Z"
ORGANIZATION "IETF EMAN Working Group"
CONTACT-INFO
"WG Charter:
http://datatracker.ietf.org/wg/eman/charter/
Mailing Lists:
General Discussion: eman@ietf.org
To Subscribe: https://www.ietf.org/mailman/listinfo/eman
Archive: http://www.ietf.org/mail-archive/web/eman
Editors:
John Parello
Cisco Systems, Inc.
3550 Cisco Way
San Jose, California 95134
United States
Phone: +1 408 525 2339
Email: jparello@cisco.com
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Degem 1831
Belgium
Phone: +32 2 704 5622
Email: bclaise@cisco.com
Mouli Chandramouli
Cisco Systems, Inc.
Sarjapur Outer Ring Road
Bangalore 560103
India
Phone: +91 80 4429 2409
Email: moulchan@cisco.com"
DESCRIPTION
"Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).
Parello, et al. Standards Track [Page 13]
^L
RFC 7461 Energy Object Context MIB March 2015
This MIB is used for describing the identity and the
context information of Energy Objects."
REVISION
"201502090000Z"
DESCRIPTION
"Initial version, published as RFC 7461."
::= { mib-2 231 }
energyObjectContextMIBNotifs OBJECT IDENTIFIER
::= { energyObjectContextMIB 0 }
energyObjectContextMIBObjects OBJECT IDENTIFIER
::= { energyObjectContextMIB 1 }
energyObjectContextMIBConform OBJECT IDENTIFIER
::= { energyObjectContextMIB 2 }
-- Textual Conventions
PethPsePortIndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
pethPsePortIndex convention, which defines a greater-
than-zero value used to identify a power Ethernet Power
Sourcing Equipment (PSE) port.
This extension permits the additional value of zero. The
semantics of the value zero are object-specific and must,
therefore, be defined as part of the description of any
object that uses this syntax. Examples of the usage of
this extension are situations where none or all physical
entities need to be referenced."
SYNTAX Integer32 (0..2147483647)
PethPsePortGroupIndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
pethPsePortGroupIndex convention from the Power Over
Ethernet MIB in RFC 3621, which defines a greater-than-zero
value used to identify the group containing the port to which
a power Ethernet PSE is connected. This extension
permits the additional value of zero. The semantics of
the value zero are object-specific and must, therefore,
Parello, et al. Standards Track [Page 14]
^L
RFC 7461 Energy Object Context MIB March 2015
be defined as part of the description of any object that
uses this syntax. Examples of the usage of this
extension are situations where none or all physical
entities need to be referenced."
SYNTAX Integer32 (0..2147483647)
LldpPortNumberOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
LldpPortNumber convention specified in the LLDP MIB,
which defines a greater than zero value used to uniquely
identify each port contained in the chassis (that is
known to the LLDP agent) by a port number. This
extension permits the additional value of zero. The
semantics of the value zero are object-specific and must,
therefore, be defined as part of the description of any
object that uses this syntax. Examples of the usage of
this extension are situations where none or all physical
entities need to be referenced."
SYNTAX Integer32(0..4096)
EnergyObjectKeywordList ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A list of keywords that can be used to group Energy
Objects for reporting or searching. If multiple keywords
are present, then this string will contain all the
keywords separated by the ',' character. All alphanumeric
characters and symbols (other than a comma), such as #,
(, $, !, and &, are allowed. White spaces before and
after the commas are ignored, as well as within a keyword
itself.
For example, if an Energy Object were to be tagged with
the keyword values 'hospitality' and 'guest', then the
keyword list will be 'hospitality,guest'."
SYNTAX OCTET STRING (SIZE (0..2048))
-- Objects
eoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists Energy Objects."
Parello, et al. Standards Track [Page 15]
^L
RFC 7461 Energy Object Context MIB March 2015
::= { energyObjectContextMIBObjects 1 }
eoEntry OBJECT-TYPE
SYNTAX EoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describes the attributes of an Energy Object.
Whenever a new Energy Object is added or an existing
Energy Object is deleted, a row in the eoTable is added
or deleted."
INDEX {entPhysicalIndex }
::= { eoTable 1 }
EoEntry ::= SEQUENCE {
eoEthPortIndex PethPsePortIndexOrZero,
eoEthPortGrpIndex PethPsePortGroupIndexOrZero,
eoLldpPortNumber LldpPortNumberOrZero,
eoMgmtMacAddress MacAddress,
eoMgmtAddressType InetAddressType,
eoMgmtAddress InetAddress,
eoMgmtDNSName OCTET STRING,
eoDomainName SnmpAdminString,
eoRoleDescription SnmpAdminString,
eoKeywords EnergyObjectKeywordList,
eoImportance Integer32,
eoPowerCategory INTEGER,
eoAlternateKey SnmpAdminString,
eoPowerInterfaceType INTEGER
}
eoEthPortIndex OBJECT-TYPE
SYNTAX PethPsePortIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable uniquely identifies the power Ethernet
port to which a Power over Ethernet device is connected.
If the Power over Ethernet MIB in RFC 3621 is supported by
the SNMP agent managing the Energy Object, then the
Energy Object eoethPortIndex MUST contain the
corresponding value of pethPsePortIndex. If such a power
Ethernet port cannot be specified or is not known, then
the object is zero."
REFERENCE
"RFC 3621: Power Ethernet MIB"
DEFVAL { 0 }
Parello, et al. Standards Track [Page 16]
^L
RFC 7461 Energy Object Context MIB March 2015
::= { eoEntry 1 }
eoEthPortGrpIndex OBJECT-TYPE
SYNTAX PethPsePortGroupIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable uniquely identifies the group containing
the port to which a power over Ethernet device PSE is
connected (RFC 3621). If the Power over Ethernet MIB (RFC
3621) is supported by the SNMP agent managing the Energy
Object, then the Energy Object eoEthPortGrpIndex MUST
contain the corresponding value of eoethPortGrpIndex. If
such a power Ethernet port cannot be specified or is not
known, then the object is zero."
REFERENCE
"RFC 3621: Power Ethernet MIB"
DEFVAL { 0 }
::= { eoEntry 2 }
eoLldpPortNumber OBJECT-TYPE
SYNTAX LldpPortNumberOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable uniquely identifies the port component
(contained in the local chassis with the LLDP agent) as
defined by the lldpLocPortNum in the LLDP-MIB and
LLDP-MED-MIB. If the LLDP-MIB is supported by the
SNMP agent managing the Energy Object, then the Energy
Object eoLldpPortNumber MUST contain the corresponding
value of lldpLocPortNum from the LLDP-MIB. If such a
port number cannot be specified or is not known, then the
object is zero."
REFERENCE
"LLDP MIB, IEEE 802.1AB-2005; LLDP-MED-MIB, ANSI/TIA-1057"
DEFVAL { 0 }
::= { eoEntry 3 }
eoMgmtMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies a Media Access Control (MAC) address
of the Energy Object."
::= { eoEntry 4 }
Parello, et al. Standards Track [Page 17]
^L
RFC 7461 Energy Object Context MIB March 2015
eoMgmtAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the eoMgmtAddress type, i.e., an
IPv4 or IPv6 address. This object MUST be
populated when eoMgmtAddress is populated."
::= { eoEntry 5 }
eoMgmtAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the management address as an IPv4
address or IPv6 address of Energy Object. The IP address
type, i.e. IPv4 or IPv6, is determined by the
eoMgmtAddressType value. This object can be used as an
alternate key to help link the Energy Object with other
keyed information that may be stored within the EnMS(s)."
::= { eoEntry 6 }
eoMgmtDNSName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies a DNS name of the eoMgmtAddress.
This object can be used as an alternate key to help link
the Energy Object with other keyed information that may
be stored within the EnMS(s). A DNS Name must always be a
fully qualified name. This MIB uses the same encoding as
the DNS protocol."
REFERENCE
"RFC 1034: Domain names - concepts and facilities,
Section 3.1."
::= { eoEntry 7 }
eoDomainName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the name of an Energy Management
Domain for the Energy Object. By default, this object
should be an empty string. The value of eoDomainName must
remain constant at least from one re-initialization of
Parello, et al. Standards Track [Page 18]
^L
RFC 7461 Energy Object Context MIB March 2015
the entity local management system to the next re-
initialization."
::= { eoEntry 8 }
eoRoleDescription OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies an administratively assigned name
to indicate the purpose an Energy Object serves in the
network.
For example, we can have a phone deployed to a lobby with
eoRoleDescription as 'Lobby phone'.
This object specifies that the value is the zero-length
string value if no role description is configured.
The value of eoRoleDescription must remain constant at
least from one re-initialization of the entity local
management system to the next re-initialization."
::= { eoEntry 9 }
eoKeywords OBJECT-TYPE
SYNTAX EnergyObjectKeywordList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies a list of keywords that can be
used to group Energy Objects for reporting or searching.
The value is the zero-length string if no keywords have
been configured. If multiple keywords are present, then
this string will contain all the keywords separated by
the ',' character. For example, if an Energy Object were
to be tagged with the keyword values 'hospitality' and
'guest', then the keyword list will be
'hospitality,guest'.
If write access is implemented and a value is written
into the instance, the agent must retain the supplied
value in the eoKeywords instance associated with
the same physical entity for as long as that entity
remains instantiated. This includes instantiations
across all re-initializations/reboots of the local
management agent."
::= { eoEntry 10 }
eoImportance OBJECT-TYPE
Parello, et al. Standards Track [Page 19]
^L
RFC 7461 Energy Object Context MIB March 2015
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies a ranking of how important the
Energy Object is (on a scale of 1 to 100) compared with
other Energy Objects in the same Energy Management
Domain. The ranking should provide a business or
operational context for the Energy Object as compared to
other similar Energy Objects. This ranking could be used
as input for policy-based network management.
Although network managers must establish their own
ranking, the following is a broad recommendation:
90 to 100 Emergency response
80 to 89 Executive or business critical
70 to 79 General or average
60 to 69 Staff or support
40 to 59 Public or guest
1 to 39 Decorative or hospitality
The value of eoImportance must remain constant at least
from one re-initialization of the Energy Object local
management system to the next re-initialization."
DEFVAL { 1 }
::= { eoEntry 11 }
eoPowerCategory OBJECT-TYPE
SYNTAX INTEGER {
consumer(0),
producer(1),
meter(2),
distributor(3),
store(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the Energy Object category, which
indicates the expected behavior or physical property of
the Energy Object, based on its design. An Energy Object
can be a consumer(0), producer(1), meter(2),
distributor(3), or store(4).
In some cases, a meter is required to measure the power
consumption. In such a case, this meter Energy Object
category is meter(2). If a device is distributing
Parello, et al. Standards Track [Page 20]
^L
RFC 7461 Energy Object Context MIB March 2015
electric Energy, the category of the Energy Object is
distributor (3). If a device is storing electric Energy,
the category of the device can be store (4)."
::= { eoEntry 12 }
eoAlternateKey OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The eoAlternateKey object specifies an alternate key
string that can be used to identify the Energy Object.
Since Energy Management Systems (EnMS) and Network
Management Systems (NMSs) may need to correlate objects
across management systems, this alternate key is provided
to provide such a link. This optional value is intended
as a foreign key or alternate identifier for a
manufacturer or EnMS/NMS to use to correlate the unique
Energy Object Id in other systems or namespaces. If an
alternate key is not available or is not applicable, then
the value is the zero-length string.
The value of eoAlternateKey must remain constant at
least from one re-initialization of the entity local
management system to the next re-initialization."
::= { eoEntry 13 }
eoPowerInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
inlet(0),
outlet(1),
both(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the Power Interface for an Energy
Object. A Power Interface is an interface at which an
Energy Object is connected to a power transmission
medium, at which it can in turn receive power, provide
power, or both. A Power Interface type can be an inlet(0),
an outlet(1), or both(2), respectively."
::= { eoEntry 14 }
eoRelationTable OBJECT-TYPE
SYNTAX SEQUENCE OF EoRelationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Parello, et al. Standards Track [Page 21]
^L
RFC 7461 Energy Object Context MIB March 2015
"This table describes the relationships between Energy
Objects."
::= { energyObjectContextMIBObjects 2 }
eoRelationEntry OBJECT-TYPE
SYNTAX EoRelationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table specifies the Energy relationship
between Energy objects. Energy relations between two
Energy objects are defined in RFC 7326."
REFERENCE
" RFC 7326: Energy Management Framework"
INDEX { entPhysicalIndex, eoRelationIndex }
::= { eoRelationTable 1 }
EoRelationEntry ::= SEQUENCE {
eoRelationIndex Integer32,
eoRelationID UUIDorZero,
eoRelationship IANAEnergyRelationship,
eoRelationStatus RowStatus,
eoRelationStorageType StorageType
}
eoRelationIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an arbitrary index to identify the Energy
Object related to another Energy Object."
::= { eoRelationEntry 1 }
eoRelationID OBJECT-TYPE
SYNTAX UUIDorZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Universally Unique Identifier
(UUID) of the peer (other) Energy Object. The UUID must
comply with the specifications of UUID in UUID-TC-MIB.
If the UUID of the Energy Object is unknown or nonexistent,
the eoRelationID will be set to a zero-length string
instead. It is preferable that the value of
entPhysicalUUID from ENTITY-MIB is used for values for
this object."
Parello, et al. Standards Track [Page 22]
^L
RFC 7461 Energy Object Context MIB March 2015
REFERENCE
"RFC 6933: Entity MIB (Version 4)"
::= { eoRelationEntry 2 }
eoRelationship OBJECT-TYPE
SYNTAX IANAEnergyRelationship
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object describes the relations between Energy
Objects. For each Energy Object, the relations between
the other Energy Objects are specified using the bitmap."
::= { eoRelationEntry 3 }
eoRelationStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status controls and reflects the creation and
activation status of a row in this table to specify energy
relationship between Energy Objects.
An entry status may not be active(1) unless all objects in
the entry have the appropriate values.
No attempt to modify a row columnar object instance value
in the eoRelationTable should be issued while the value of
eoRelationStatus is active(1). The data can be destroyed by
setting up the eoRelationStatus to destroy(2)."
::= { eoRelationEntry 4 }
eoRelationStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this row."
DEFVAL { nonVolatile }
::= {eoRelationEntry 5 }
-- Conformance
energyObjectContextMIBCompliances OBJECT IDENTIFIER
::= { energyObjectContextMIBConform 1 }
energyObjectContextMIBGroups OBJECT IDENTIFIER
Parello, et al. Standards Track [Page 23]
^L
RFC 7461 Energy Object Context MIB March 2015
::= { energyObjectContextMIBConform 2 }
energyObjectContextMIBFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"When this MIB is implemented with support for
read-write, then such an implementation can
claim full compliance. Such devices can then
be both monitored and configured with this MIB.
Module Compliance of ENTITY-MIB with respect to
entity4CRCompliance MUST be supported."
MODULE -- this module
MANDATORY-GROUPS {
energyObjectContextMIBTableGroup,
energyObjectRelationTableGroup
}
GROUP energyObjectOptionalMIBTableGroup
DESCRIPTION
"A compliant implementation does not have to
implement."
::= { energyObjectContextMIBCompliances 1 }
energyObjectContextMIBReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"When this MIB is implemented without support for
read-write (i.e., in read-only mode), then such an
implementation can claim read-only compliance.
Such a device can then be monitored but cannot be
configured with this MIB.
Module Compliance of ENTITY-MIB with respect to
entity4CRCompliance MUST be supported."
MODULE -- this module
MANDATORY-GROUPS {
energyObjectContextMIBTableGroup,
energyObjectRelationTableGroup
}
GROUP energyObjectOptionalMIBTableGroup
DESCRIPTION
"A compliant implementation does not have to implement
the managed objects in this GROUP."
::= { energyObjectContextMIBCompliances 2 }
Parello, et al. Standards Track [Page 24]
^L
RFC 7461 Energy Object Context MIB March 2015
-- Units of Conformance
energyObjectContextMIBTableGroup OBJECT-GROUP
OBJECTS {
eoDomainName,
eoRoleDescription,
eoAlternateKey,
eoKeywords,
eoImportance,
eoPowerCategory,
eoPowerInterfaceType
}
STATUS current
DESCRIPTION
"This group contains the collection of all the objects
related to the EnergyObject."
::= { energyObjectContextMIBGroups 1 }
energyObjectOptionalMIBTableGroup OBJECT-GROUP
OBJECTS {
eoEthPortIndex,
eoEthPortGrpIndex,
eoLldpPortNumber,
eoMgmtMacAddress,
eoMgmtAddressType,
eoMgmtAddress,
eoMgmtDNSName
}
STATUS current
DESCRIPTION
"This group contains the collection of all the objects
related to the Energy Object."
::= { energyObjectContextMIBGroups 2 }
energyObjectRelationTableGroup OBJECT-GROUP
OBJECTS {
eoRelationID,
eoRelationship,
eoRelationStatus,
eoRelationStorageType
}
STATUS current
DESCRIPTION
"This group contains the collection of all objects
specifying the relationship between Energy Objects."
::= { energyObjectContextMIBGroups 3 }
END
Parello, et al. Standards Track [Page 25]
^L
RFC 7461 Energy Object Context MIB March 2015
IANA-ENERGY-RELATION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC;
ianaEnergyRelationMIB MODULE-IDENTITY
LAST-UPDATED "201502090000Z" -- February 9, 2015
ORGANIZATION "IANA"
CONTACT-INFO "
Internet Assigned Numbers Authority
Postal: ICANN
12025 Waterfront Dr., Suite 300
Los Angeles, CA 90094
United States
Tel: +1-310-301-5800
EMail: iana@iana.org"
DESCRIPTION
"Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD
License set forth in Section 4.c of the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info).
This MIB module defines a TEXTUAL-CONVENTION that
describes the relationships between Energy Objects.
The initial version of this MIB module was published in
RFC 7461; for full legal notices see the RFC itself."
REVISION "201502090000Z" -- February 9, 2015
DESCRIPTION "Initial version of this MIB as published in
RFC 7461."
::= { mib-2 232 }
-- Textual Conventions
IANAEnergyRelationship ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value specifying the type of
relationship between an Energy Object A, on
Parello, et al. Standards Track [Page 26]
^L
RFC 7461 Energy Object Context MIB March 2015
which the relationship is specified, with the
Energy Object B, identified by the UUID.
The enumeration 'poweredBy' is applicable if
Energy Object A is poweredBy Energy Object B.
The enumeration 'powering' is applicable if
Energy Object A is powering Energy Object B.
The enumeration 'meteredBy' is applicable if
Energy Object A is meteredBy Energy Object B.
The enumeration 'metering' is applicable if
Energy Object A is metering Energy Object B.
The enumeration 'aggregatedBy' is applicable if
Energy Object A is aggregatedBy Energy Object B.
The enumeration 'aggregating' is applicable if
Energy Object A is aggregating Energy Object B."
SYNTAX INTEGER {
poweredBy(1), -- power relationship
powering(2),
meteredBy(3), -- meter relationship
metering(4),
aggregatedBy(5), -- aggregation relationship
aggregating(6)
}
END
6. Security Considerations
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection opens devices to attack. These
are the tables and objects and their sensitivity/vulnerability:
Unauthorized changes to the eoDomainName, entPhysicalName,
eoRoleDescription, eoKeywords, eoImportance, eoAlternateKey,
eoRelationID, eoRelationship, eoRelationStatus, and/or
eoRelationStorageType MAY disrupt power and energy collection, and
therefore any predefined policies defined in the network.
Parello, et al. Standards Track [Page 27]
^L
RFC 7461 Energy Object Context MIB March 2015
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
there is no control as to who on the secure network is allowed to
access and GET/SET (read/change/create/delete) the objects in this
MIB module.
Implementations SHOULD provide the security features described by the
SNMPv3 framework (see [RFC3410]), and implementations claiming
compliance to the SNMPv3 standard MUST include full support for
authentication and privacy via the User-based Security Model (USM)
[RFC3414] with the AES cipher algorithm [RFC3826]. Implementations
MAY also provide support for the Transport Security Model (TSM)
[RFC5591] in combination with a secure transport such as SSH
[RFC5592] or TLS/DTLS [RFC6353].
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
In certain situations, energy and power monitoring can reveal
sensitive information about individuals' activities and habits.
Implementors of this specification should use appropriate privacy
protections as discussed in Section 9 of RFC 6988 and monitoring of
individuals and homes should only occur with proper authorization.
7. IANA Considerations
The MIB modules in this document use the following IANA-assigned
OBJECT IDENTIFIER values recorded in the SMI Numbers registry:
Descriptor OBJECT IDENTIFIER Value
---------- -----------------------
energyObjectContextMIB { mib-2 231 }
This document defines the first version of the IANA-maintained IANA-
ENERGY-RELATION-MIB module, which allows new definitions of
relationships between Energy Objects.
A Specification Required as defined in [RFC5226] is REQUIRED for each
modification of the energy relationships.
The MIB module in this document uses the following IANA-assigned
OBJECT IDENTIFIER values recorded in the SMI Numbers registry.
Parello, et al. Standards Track [Page 28]
^L
RFC 7461 Energy Object Context MIB March 2015
Descriptor OBJECT IDENTIFIER Value
---------- -----------------------
ianaEnergyRelationMIB { mib-2 232 }
8. References
8.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997,
<http://www.rfc-editor.org/info/rfc2119>.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999,
<http://www.rfc-editor.org/info/rfc2578>.
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2", STD
58, RFC 2579, April 1999,
<http://www.rfc-editor.org/info/rfc2579>.
[RFC2580] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Conformance Statements for SMIv2",
STD 58, RFC 2580, April 1999,
<http://www.rfc-editor.org/info/rfc2580>.
[RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", STD 62, RFC 3414, December 2002,
<http://www.rfc-editor.org/info/rfc3414>.
[RFC3621] Berger, A. and D. Romascanu, "Power Ethernet MIB", RFC
3621, December 2003,
<http://www.rfc-editor.org/info/rfc3621>.
[RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The
Advanced Encryption Standard (AES) Cipher Algorithm in the
SNMP User-based Security Model", RFC 3826, June 2004,
<http://www.rfc-editor.org/info/rfc3826>.
[RFC4122] Leach, P., Mealling, M., and R. Salz, "A Universally
Unique IDentifier (UUID) URN Namespace", RFC 4122, July
2005, <http://www.rfc-editor.org/info/rfc4122>.
Parello, et al. Standards Track [Page 29]
^L
RFC 7461 Energy Object Context MIB March 2015
[RFC5591] Harrington, D. and W. Hardaker, "Transport Security Model
for the Simple Network Management Protocol (SNMP)", STD
78, RFC 5591, June 2009,
<http://www.rfc-editor.org/info/rfc5591>.
[RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure
Shell Transport Model for the Simple Network Management
Protocol (SNMP)", RFC 5592, June 2009,
<http://www.rfc-editor.org/info/rfc5592>.
[RFC6353] Hardaker, W., "Transport Layer Security (TLS) Transport
Model for the Simple Network Management Protocol (SNMP)",
STD 78, RFC 6353, July 2011,
<http://www.rfc-editor.org/info/rfc6353>.
[RFC6933] Bierman, A., Romascanu, D., Quittek, J., and M.
Chandramouli, "Entity MIB (Version 4)", RFC 6933, May
2013, <http://www.rfc-editor.org/info/rfc6933>.
[RFC7460] Chandramouli, Claise, B., Schoening, B., Quittek, J., and
Dietz, T., "Monitoring and Control MIB for Power and
Energy", RFC 7460, March 2015,
<http://www.rfc-editor.org/info/rfc7460>.
[LLDP-MED-MIB]
ANSI/TIA-1057, "The LLDP Management Information Base
extension module for TIA-TR41.4 media endpoint discovery
information", July 2005.
[LLDP-MIB] IEEE, "Management Information Base module for LLDP
configuration, statistics, local system data and remote
systems data components", IEEE 802.1AB, May 2005.
8.2. Informative References
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002,
<http://www.rfc-editor.org/info/rfc3410>.
[RFC3433] Bierman, A., Romascanu, D., and K. Norseth, "Entity Sensor
Management Information Base", RFC 3433, December 2002,
<http://www.rfc-editor.org/info/rfc3433>.
[RFC5226] Narten, T. and H. Alvestrand, "Guidelines for Writing an
IANA Considerations Section in RFCs", BCP 26, RFC 5226,
May 2008, <http://www.rfc-editor.org/info/rfc5226>.
Parello, et al. Standards Track [Page 30]
^L
RFC 7461 Energy Object Context MIB March 2015
[RFC6988] Quittek, J., Ed., Chandramouli, M., Winter, R., Dietz, T.,
and B. Claise, "Requirements for Energy Management", RFC
6988, September 2013,
<http://www.rfc-editor.org/info/rfc6988>.
[RFC7326] Parello, J., Claise, B., Schoening, B., and J. Quittek,
"Energy Management Framework", RFC 7326, September 2014,
<http://www.rfc-editor.org/info/rfc7326>.
[EMAN-AS] Schoening, B., Chandramouli, M., and B. Nordman, "Energy
Management (EMAN) Applicability Statement", Work in
Progress, draft-ietf-eman-applicability-statement-08,
December 2014.
Acknowledgements
We would like to thank Juergen Quittek and Juergen Schoenwalder for
their suggestions on the new design of eoRelationTable, which was a
proposed solution for the open issue on the representation of Energy
Object as a UUID list.
Many thanks to Juergen Quittek for many comments on the wording,
text, and design of the MIB thus resulting in an improved document.
Many thanks to Alan Luchuk for the review of the MIB and his
comments.
In addition, the authors thank Bill Mielke for his multiple reviews,
Brad Schoening and Juergen Schoenwaelder for their suggestions, and
Michael Brown for dramatically improving this document.
Finally, thanks to the EMAN WG chairs: Nevil Brownlee and Tom Nadeau.
Parello, et al. Standards Track [Page 31]
^L
RFC 7461 Energy Object Context MIB March 2015
Authors' Addresses
John Parello
Cisco Systems, Inc.
3550 Cisco Way
San Jose, California 95134
United States
Phone: +1 408 525 2339
EMail: jparello@cisco.com
Benoit Claise
Cisco Systems, Inc.
De Kleetlaan 6a b1
Diegem 1813
Belgium
Phone: +32 2 704 5622
EMail: bclaise@cisco.com
Mouli Chandramouli
Cisco Systems, Inc.
Sarjapur Outer Ring Road
Bangalore 560103
India
Phone: +91 80 4429 2409
EMail: moulchan@cisco.com
Parello, et al. Standards Track [Page 32]
^L
|